1 HFS 1000 Hopper/Feeder System Manual Number: MZ012 Release Date: November 2006
2 2006 Valco Cincinnati, Inc. All Rights Reserved. This manual is furnished with the HFS 1000 hopper/feeder system and may be used or copied only in accordance with the terms of purchase. No part of this manual may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, recording, or otherwise, without the prior written permission of Valco Cincinnati, Inc. The information in this manual is furnished for educational purposes only, is subject to change without notice, and should not be construed as a commitment by Valco Cincinnati, Inc. This manual was written and designed at Valco Cincinnati, Inc., 411 Circle Freeway Drive, Cincinnati, Ohio Part Number: MZ012 Printed in the USA Valco Cincinnati Incorporated 411 Circle Freeway Drive Cincinnati, Ohio TEL: (513) FAX: (513) Valco Cincinnati Limited Hortonwood 32 Telford, TF1 7YN, England TEL: (+44) FAX: (+44) Valco GmbH Storkower Str. 6 D Gallun,Germany TEL: (+49) FAX: (+49)
3 Table of Contents Section 1 Introduction About this Manual Section 2 Safety Information General Information Warnings Cautions What to do if Contact with Hot Adhesive Occurs What to do if Fire/Exposion Occurs What to do if Inhalation of Adhesive Fumes Occurs Section 3 General Wiring Guidelines Routing Low-Voltage Leads Connecting the Supply of Electrical Power Section 4 Basic Features Description of the HFS 1000 Hopper/Feeder System Section 5 Installation Installing the HFS Mechanical/Electrical Installation Section 6 Calibrating/Testing Calibrating the HFS Testing the HFS Final Test Section 7 Troubleshooting Section 8 Part-Number List How to Order Parts HFS 1000 Parts List Section 9 Warranty Warranty Information Cold-Glue Equipment and Electronic Controls Hot-Melt Units, Hoses, Valves, and Related Equipment Section 10 Service Service Needs
4 Section 1 Introduction Since hot-melt adhesive has been in use, the melt tank has often demanded considerable attention from the system's operator. If proper attention is not paid to the melt tank, the following situations can develop and possibly hamper productivity. If adhesive is not added to the melt tank when necessary, there is insufficient time to melt and condition the adhesive. While the operator waits for the adhesive to rise to the required application temperature, production line speed is reduced and product output suffers. If the melt tank or the adhesive case is left open or is being opened and closed during the filling procedure, external debris, box dust or pieces of corrugated material can contaminate the system. The result is decreased production and increased maintenance costs because of char formation causing plugged nozzles, clogged filters, and cut seals. As the adhesive level in the melt tank drops, adhesive residue remains on the walls of the tank. The combination of high temperature, adhesive residue, and oxygen causes char to form on the melt tank's interior walls. Eventually, the char breaks free and enters the system. Again, production goes down while maintenance costs increase. The HFS 1000 Hopper Feeder System automatically maintains a constant level of adhesive in the melt tank and provides a barrier to prevent the entry of debris into the system. About this Manual Valco Cincinnati has prepared this manual as an aid for installing, operating, and servicing the HFS 1000 hopper/ feeder system. It also contains a list of part numbers for replacement parts. If you need more information, please contact your Valco Cincinnati representative. Valco Cincinnati 1-1
5 Section 2 Safety Information General Information It is the purchaser s responsibility to ensure that all local, county, state, and national codes, regulations, rules, and laws relating to safety and safe operating conditions are met and followed. The best safeguard is trained personnel. The purchaser is responsible for providing personnel who are adequately trained to install, operate, and maintain Valco components and systems. This section contains information that is essential to the safety of personnel. Safety information is included throughout the rest of the manual as well. The following safety conventions are used to indicate potential safety hazards: WARNING! This symbol indicates the presence of un-insulated dangerous voltage within the product s enclosure. This voltage may cause electrical shock or fire. FAILURE TO OBSERVE WARNING MAY RESULT IN DEATH, PERSONAL INJURY, AND/OR EQUIPMENT DAMAGE. WARNING! This convention is used to alert the user to important installation, operation, and/or maintenance information. FAILURE TO OBSERVE WARN- ING MAY RESULT IN DEATH, PERSONAL INJURY, AND/OR EQUIPMENT DAMAGE. CAUTION! This convention is used to alert the user to important installation, operation, and/or maintenance information. FAILURE TO OBSERVE CAUTION MAY CAUSE EQUIPMENT DAMAGE. Warnings All personnel involved with the installation, operation, and maintenance of the equipment must read and thoroughly understand the following warnings: WARNING! Disconnect all power before opening the control. OTHERWISE, DEATH OR PERSONAL INJURY COULD OCCUR. Only qualified personnel should open and service the control. WARNING! Promptly repair or replace all worn or damaged electrical wiring and equipment wires. OTHERWISE, DEATH OR PERSONAL INJURY COULD OCCUR. WARNING! Properly route all electrical wires. OTHERWISE, DEATH, PER- SONAL INJURY, OR DAMAGE TO THE MOVING PARTS OF THE MACHINE MAY OCCUR. Valco Cincinnati 2-1
6 Section 2 Safety Information HFS 1000 Hopper/Feeder System WARNING! When making adjustments or performing checkout procedures, stay clear of any moving mechanical parts and do not touch exposed electrical equipment or electrical connectors. OTHERWISE, DEATH OR PERSONAL INJURY COULD OCCUR. WARNING! Keep pump cover and electrical enclosures closed except during setup, service, and checkout procedures. OTHERWISE, DEATH OR PER- SONAL INJURY COULD OCCUR. WARNING! Promptly repair or replace all worn or damaged parts. OTHER- WISE, PERSONAL INJURY OR EQUIPMENT DAMAGE COULD OCCUR. Cautions WARNING! Always wear insulated gloves and proper eye protection when working around hot-melt equipment. A protective screen around the face is also recommended. OTHERWISE, DEATH OR PERSONAL INJURY COULD OCCUR. WARNING! Purge the fluid pressure from the system before disconnecting any part of the system. OTHERWISE, DEATH OR PERSONAL INJURY COULD OCCUR. WARNING! People with respiratory problems (e.g., asthma, bronchitis, etc.) should not work in the vicinity of molten adhesive. RESPIRATORY PROB- LEMS MAY BE AGGRAVATED BY THE FUMES. Do not wear a face mask when working around molten adhesive. THE MASK MAY TRAP THE FUMES AND DEATH OR PERSONAL INJURY COULD OCCUR. WARNING! Keep hot-melt hoses away from walkways and the moving parts of hot-melt systems. OTHERWISE, PERSONAL INJURY OR EQUIPMENT DAMAGE COULD OCCUR. WARNING! The hot-melt unit should be installed so that it can be turned off at a location away from the hot-melt unit. OTHERWISE, DEATH, PERSONAL INJURY, OR EQUIPMENT DAMAGE COULD OCCUR. All personnel involved with the installation, operation, and maintenance of the equipment must read and thoroughly understand the following cautions: CAUTION! Never hose or steam-clean the unit. If the surrounding area is cleaned in this manner, protect the unit by covering it with plastic or other waterproof material. OTHERWISE, DAMAGE TO EQUIPMENT COULD OCCUR. CAUTION! Do not bend hot-melt hoses less than an 18-inch (460 mm) radius. OTHERWISE, EQUIPMENT DAMAGE COULD OCCUR. CAUTION! Place Material Safety Data Sheets for the adhesive near the unit. OTHERWISE, DAMAGE TO EQUIPMENT COULD OCCUR. 2-2 Valco Cincinnati
7 HFS 1000 Hopper/Feeder System Section 2 Safety Information What to Do if Contact with Hot Adhesive Occurs WARNING! The heat that is contained in hot-melt material will continue to penetrate and deeply burn the skin unless rapidly cooled by external means such as water. Do not attempt to remove set hot-melt adhesive from the skin. OTHERWISE, PERSONAL INJURY COULD OCCUR. If hot adhesive comes in contact with the skin, do the following: 1. Immediately immerse the contacted area in clean, cold water. Note! It is recommended that a source of clean, cold water be provided near the hot-melt work area. 2. Cover the affected area with a clean, wet compress and see a physician immediately. What to Do if Adhesive-Related Fire or Explosion Occurs During the heating and melting process, the surface of the adhesive will be exposed to air. The mixture of polymer fumes and air can catch fire if the hot-melt is overheated. WARNING! Poor ventilation, smoking, and open flames can cause overheated hot-melt to ignite. Adequate ventilation must be provided. Smoking should be prohibited in the immediate vicinity of the molten adhesive. Open flames must be kept away from the area around molten adhesive. OTHERWISE, DEATH, PERSONAL INJURY, OR DAMAGE TO EQUIPMENT COULD OCCUR. WARNING! Exposed arcing may ignite the fume/air mixture. Shield all electrical equipment from melt fumes to avoid exposed arcing. OTHERWISE, PER- SONAL INJURY OR EQUIPMENT DAMAGE COULD OCCUR. WARNING! Do not use a water extinguisher to extinguish the fire! OTHER- WISE, PERSONAL INJURY OR EQUIPMENT DAMAGE COULD OCCUR. If the hot-melt adhesive ignites, promptly perform the following steps: 1. Sound a fire alarm. 2. Evacuate the immediate area. 3. Turn off all local electrical equipment at the source. 4. Fight the fire in one of the following ways: Smother the fire with a fire blanket. Aim a CO 2 fire extinguisher at the base of the flames. Aim a dry-powder fire extinguisher at the base of the flames. Valco Cincinnati 2-3
8 Section 2 Safety Information HFS 1000 Hopper/Feeder System What to Do if Inhalation of Adhesive Fumes Occurs If Adhesive fumes are inhaled, immediately follow these steps: 1. Take the victim away from the immediate work area. 2. Provide victim with fresh air. 3. Call a qualified medical authority. 2-4 Valco Cincinnati
9 Section 3 General Wiring Guidelines Routing Low-Voltage Leads WARNING! Electrical installation should be made only by experienced service personnel! OTHERWISE, DEATH, PERSONAL INJURY, OR EQUIP- MENT DAMAGE COULD OCCUR. When routing low-voltage leads, follow these guidelines: Do not route low-voltage leads in the same conduit as wires carrying a high-current load. Do not route low-voltage leads adjacent to, or across wires carrying a high-current load. If low-voltage leads must cross or run parallel to wires carrying high current, keep the leads at least 6" (152 mm) from high-current wires. Do not splice or solder leads. Trim leads to the required length. Leads should be only as long as necessary for installation. All wiring should be in conduits or wireways. Connecting the Supply of Electrical Power WARNING! Electrical connections should be made only by experienced service personnel! OTHERWISE, DEATH, PERSONAL INJURY, OR EQUIP- MENT DAMAGE COULD OCCUR. When connecting the supply of electrical power, follow these guidelines: Connect the control to a clean supply of electrical power. Use a dedicated circuit if possible. Note! If a dedicated circuit is not available, do not connect the control to a circuit that supplies highamperage equipment use another circuit such as a lighting circuit. Otherwise, equipment may not function properly. Valco Cincinnati 3-1
10 Section 4 Basic Features Description of the HFS 1000 Hopper/Feeder System The HFS 1000 Hopper/Feeder System utilizes an air-driven, vacuum-transducer to deliver hot melt from the bulkadhesive container to the hot-melt unit. The transducer and a vibrator are attached to the bottom of the bulkadhesive container. The HFS 1000 system can deliver hot-melt chips up to 20 feet away and transfer chips up to 5/ 8" square. The level probe contains a sensor that signals the system to either fill or shut off, depending on the level of adhesive in the unit. If adhesive is below the level probe, the sensor signals the system to activate. When the system is activated, the green LED on the control box illuminates and the hot melt is transported from the container to the hotmelt unit. If the system does not fill in a specific time period, an alarm sounds and the red LED on the control box illuminates. This alerts the operator of low adhesive level or a system fault. HFS 1000 Hopper/Feeder System Components Valco Cincinnati 4-1
11 Section 4 Basic Features HFS 1000 Hopper/Feeder System The HFS 1000 System s electronics allow you to easily make melt-tank adjustments, even while the production line is running. Note! The adhesive is kept at room temperature until after it is loaded into the melt tank. The HFS 1000 is not transporting hot adhesive through heated hoses and/or pipe. The level-control s sensor probe, which extends down into the melt tank, is mounted to the melt tank lid. The probe initiates a Fill cycle when it senses the adhesive level in the melt tank has dropped to the refill level. This activates the vacuum transducer and vibrator. The vibrator fluffs the adhesive to make it easier for the vacuum transducer to pull the adhesive into the system. The room-temperature adhesive is then transported through the hose that connects the container to the melt tank lid, where it drops directly into the melt tank. During this cycle, a green light located on the top of the level-control box remains on until the cycle is completed. If the melt tank s fill cycle is not completed within a specified period of time, the level-control box s red light is activated. Both the alarm light and an audio alarm will remain on until the operator pushes the reset button. The alarm s timer adjustment is located inside the control. The fill cycle s green light, vacuum transducer, and vibrator shut off when the level of adhesive in the tank rises on the level-control s sensor probe to a user-specified position. The sensor probe is not affected by temperature changes. Air requirements are approximately 20 standard cubic feet per minute for 5 to 10 seconds. Required incoming air pressure depends on the particular adhesive s flow properties. 60 psi is a good starting point. Set the vibrator s air pressure to 35 psi initially. Normally, pressure to the vibrator should not exceed 50 psi. HFS 1000 Hopper/Feeder System Control 4-2 Valco Cincinnati
12 Section 5 Installation Installing the HFS 1000 Mechanical/Electrical Installation Note! Do not add adhesive to the dispensing container until directed to do so. To install the HFS 1000 Hopper/Feeder System, follow these steps: 1. Replace the previous Valco lid with a new lid assembly or bore holes into the existing lid using the template provided. 2. Place the casting onto the lid. 3. Wire the level probe to the control: 3a. Remove the casting cover 3b. Slide the three exposed wires from the control through the cord grip on the side of the casting. 3c. Each wire has a number (either 4, 5, or 6). Attach each numbered wire to its appropriate connection inside the casting. 3d. Replace the casting cover. 4. Place the hopper section onto the lid assembly. 5. Attach one end of the braided 1-1/4" hose to the adhesive inlet pipe on the hopper section. Note! Heating the end of the hose with a hot air gun or lightly lubricating the inlet pipe will help the hose slide over the pipe. 6. Inside the control box, attach the 3/8" poly tube air line to the push-lock fitting on the air valve. 7. Inside the control box, attach the 1/4" poly tube to the air regulator push-lock fitting. 8. Attach the air filter to the outside of the control box. 9. Connect plant air to the inlet on the control box air filter. (A minimum 1/2" air line is required.) 10. Set the air transducer-regulator to 60 psi initially. Note! Different forms of hot melt require different pressures. 11. Set the air vibrator regulator to 20 psi initially. Note! Do not exceed 40 psi on the air vibrator regulator. 12. Insert the other end of the 1 1/4" braided hose into the mating pipe on the side of the bulk adhesive tote. 13. Push both the 1/4" and 3/8" tubing into the appropriate push lock fitting on the side of the bulk adhesive tote. 14. Plug the supplied power cord into an acceptable 120V outlet. 15. Use plastic ties to secure poly air lines to the hose, as well as the electrical cable from the lid assembly. Valco Cincinnati 5-1
13 Section 6 Calibrating/Testing Calibrating the HFS 1000 After installation is complete, the level probe sensor must be calibrated (See Figure, page 4-2 for the location of the sensitivity potentiometer, timing adjustment, and selector switches.) Note! Air pressure should not be applied to the system until after the level probe sensor has been calibrated. To calibrate the level probe sensor, follow these steps: 1. Manually fill the tank s adhesive level to within 1 of the bottom of the probe (when tank lid is closed). 2. Close the tank lid. 3. Set the B and the C sequence switches in the up position. 4. Set the A and the D sequence switches in the down position. 5. Open the control box. If the red LED inside is on, turn the sensitivitympotentiometer counter-clockwise in 1/2 turn increments until the red LED light goes out and the green LED comes on. Note! The red LED indicates that the adhesive level in the tank is touching the probe; the green LED indicates that the adhesive level in the tank is not touching the probe. 6. Manually fill the tank of the HSF 1000 until adhesive comes in contact with the level probe. (The red LED will come on and the green LED will shut off). Note! If this does not occur, turn the sensitivity potentiometer clockwise in 1/4 turn increments until the red LED comes on. Testing the HFS 1000 To conduct an initial test of the HFS 1000 System, follow these steps: 1. Fill the bulk adhesive container with the correct adhesive. 2. Set air pressure to 60 psi and allow the system to fill with adhesive. (The red LED will illuminate.) 3. If the red LED does not illuminate, turn the sensitivity potentiometer clockwise in 1/2 turn increments until it does illuminate. Note! The potentiometer setting can be checked by raising and lowering the tank lid. The green LED light should illuminate when the lid is raised 1/2", and go off when the lid is lowered. 4. Adjust the sensitivity potentiometer until the unit activates and deactivates when the lid is moved. The unit is now ready to operate. Valco Cincinnati 6-1
14 Section 6 Calibrating/Testing HFS 1000 Hopper/Feeder System Final Test Once the system is operational, follow these steps: 1. Observe the adhesive level in the tank after the fill cycle is complete. Note! The system electrical or system air should be turned off when observing the level. Otherwise, the filling cycle will be activated. 2. Readjust the level if adhesive is above the lower tip of the probe. Failure to obtain this low level can cause a clog in the breather or fill opening. 6-2 Valco Cincinnati
15 Section 7 Troubleshooting Problem Possible Cause Possible Solution 1. Red LED cannot be adjusted to turn illuminate. 2. Red LED remains on at all times. 3. Unit triggers when material touches probe, but will not reset when material recedes from probe or unit and gives false alarm. 4. Unit does not detect material. 5. Unit stays in calibration. 6. Relay operated properly, but no signal at terminal's circuit board. 7. Unit triggers and fill light comes on but does not fill or material "spirals" inside braided hose, but does not move. 1a. Probe lead not connected 1b. No power to unit 1c. On-board fuse blown 1d. Bad sensing card 2a. Probe shorted to case or ground. 2b. Bad sensing card 3a. Improper probe mounting 3b. Improper calibration procedure 3c. Excessive material buildup on probe 4a. Improper calibration 4b. Probe lead not plugged into probe 4c. Unit was calibrated with material touching 4d. Too much delay 5a. Poor grounding of unit to vessel 6a. Burned or broken electrical path on power-supply printed circuit 6b. Bad relay contacts 7a. Vent blocked 7b. Transducer in container blocked 7c. Transducer plugged at bottom venturi 7d. Air fitting plugged 1a. Plug probe lead into probe. 1b. Check for correct voltage to unit (120V). 1c. Replace fuse. 1d. Replace sensing card. 2a. Unplug probe lead and position it so the bare end is not touching anything. Turn calibration pot 20 turns counter clockwise. LED should go out. If it doesn t, repair, replace or clean antenna probe. 2b. Repair or replace card. 3a. Contact factory. 3b. See calibration/setup section. 3c. Clean probe and recalibrate. 4a. See calibration/set-up section. 4b. Plug probe lead into probe. 4c. Recalibrate with material not touching the probe. 4d. Check dip switches and recalibrate. 5a. Provide secure ground connection. 6a. Turn off power, remove module from housing, and inspect. 6b. Replace board. 7a. Clean out vent. 7b. Clean out inlet and transducer inlet. 7c. Remove transducer from container, and disassemble and clean inside transducer. 7d. Remove and clean fittings. Valco Cincinnati 7-1
16 Section 8 Part-Number List How to Order Parts To order parts, please contact one of the following offices: Valco Cincinnati Incorporated 411 Circle Freeway Drive Cincinnati, Ohio TEL: (513) FAX: (513) Valco Cincinnati Limited Hortonwood 32 Telford, TF1 4 EU, England TEL: (+44) FAX: (+44) Valco GmbH Storkower Str. 6 D Gallun,Germany TEL: (+49) FAX: (+49) Note! You may also contact a Valco sales representative in your country. Valco Cincinnati 8-1
17 Section 8 Part-Number List HFS 1000 Hopper/Feeder System HFS 1000 Parts List Item Number Description Part Number Quantity 01 HFS; 120V, Bent Probe 769xx Feed Tee Assembly; HFS 769xx Label, logo 794xx Label, logo 794xx Cut-out Detail; Lid 998IS Manual; HFS MZ Valco Cincinnati
18 HFS 1000 Hopper/Feeder System Section 11 Part-Number List Item Number Description Part Number Quantity 01 Feed Tee; Weldment 769xx Coupling; Tee-air Vent 769xx Louver; Aluminum, 4 769xx Label, logo 794xx917 1 Valco Cincinnati 8-3
19 Section 8 Part-Number List HFS 1000 Hopper/Feeder System Checklist HFS, 120V, Bent Probe Item Description Part Number 01 Dispense-Container Assembly; HFS 769xx Control Assembly, HFS, 120V-60Hz 098xx Casting Assembly, HFS w/o probe 775xx Transmitter, HFS 775xx Probe for HFS, 4 bent 080xx Hose, clear, reinforced, 1.25 ID 755xx Tubing (180 in) 755xx Tubing (180 in) 755xx Hose clamp 794xx Cable (15ft), 2 Cond shielded 24 AWG 030xx Filter Assembly, air inlet for HFS 594xx Valco Cincinnati
20 HFS 1000 Hopper/Feeder System Section 11 Part-Number List Item Description Part Number 01 Control board assembly, receiver, HFS 098xx Fuse, 250MA, 5x20mm, 250V 085xx Audio alarm, HFS Control 010xx Air regulator, HFS Control 594xx Gauge, air pressure, HFS Control 786xx Timer module for HFS Control 076xx Indicator light, green, HFS Control 155xx Indicator light, red, HFS Control 105xx Flasher for HFS Control 098xx Valve, sol., HIFLO for HFS 411xx Switch, reset for HFS Control 480xx Fuse, 5 AMP 085xx Switch, power for HFS Control 480xx191 Valco Cincinnati 8-5
21 Section 9 Warranty Warranty Information Valco Cincinnati, Inc. warrants its equipment worldwide against defects in material and workmanship as outlined in this section. Cold-Glue Equipment and Electronic Controls One (1) year from the date of shipment by Valco Cincinnati. Hot-Melt Units, Hoses, Valves, and Related Equipment All components except cast-in heating elements are warranted for a period of six (6) months from the date of shipment by Valco Cincinnati. Cast-in heaters carry an additional, pro-rated warranty not to exceed three (3) years from the date of shipment by Valco Cincinnati. Liability of the company is limited to repair of the product, or replacement of any part shown to be defective, and does not extend to defects caused by accidents, misuse, abuse, neglect, tampering or deterioration by corrosion. This warranty does not cover those items determined by Valco Cincinnati, Inc. to be normal wear items such as seals, O- rings, diaphragms, springs, etc. Reconditioned equipment, unless specified otherwise at the time of purchase, will be warranted as described above for a period of ninety (90) days from the date of shipment by Valco Cincinnati. Components purchased by Valco Cincinnati, Inc. from others for inclusion in its products are warranted only to the extent of the original manufacturer s warranty. In no event shall Valco Cincinnati, Inc. be liable for indirect or consequential damages arising out of the use of Valco Cincinnati products. This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to Valco Cincinnati, Inc. for examination and verification. If claimed defect is verified, repairs or replacements will be made F.O.B. Cincinnati, Ohio, U.S.A. or ex-works Telford, U.K. If the inspection of the equipment does not disclose any defect of workmanship or material, any necessary repairs will be made at a reasonable charge and return transportation will be charged. This is the only authorized Valco Cincinnati, Inc. warranty and is in lieu of all other expressed or implied warranties, representations or any other obligations on the part of Valco Cincinnati, Inc. Valco Cincinnati 9-1
22 Section 10 Service Service Needs If you have problems with your system, please contact your Valco Cincinnati representative. If your need is urgent, we encourage you to contact our corporate office in Cincinnati, Ohio, U.S.A. at (513) , or Valco Europe in the United Kingdom at (+44) If the problem cannot be resolved on the telephone, Valco will promptly arrange to have a technical representative visit your facility. Any charges for a service call will be quoted at that time.any part that fails during the warranty period shall be returned prepaid to Valco Cincinnati by the customer for disposition. Note! Upon request, Valco Cincinnati personnel are available to repair or replace such parts at the customer s facility. Charges for this service include travel time and expenses. If an equipment problem is the result of customer abuse, improper installation or operation, all travel time, labor, parts, and expenses will be charged to the customer. If the responsibility for a problem cannot be absolutely determined, the customer will be charged for travel time and expenses only. No charge will be made for parts and labor. Valco Cincinnati 10-1
JP2000 Jam Preventer Installation and Operation Manual. Manual Number: MC006
JP2000 Jam Preventer Installation and Operation Manual Manual Number: MC006 Revision Date: September 2007 2007 All Rights Reserved. This manual is furnished with the JP2000 Jam Preventer and may only be
More informationModel P4017 Single Channel USB Oscilloscope. Quick Start Guide
Model P4017 Single Channel USB Oscilloscope Quick Start Guide General Warranty BNC warrants that the product will be free from defects in materials and workmanship for 3 years from the date of purchase
More informationMODEL 245 / 345 High Range
MODEL 245 / 345 High Range PRESSURE TRANSMITTER INSTALLATION DATA MANUAL 199 Fire Tower Drive Tonawanda, NY 14150 Toll Free: 1-800-688-0030 International: 716-629-3800 Fax: 716-693-9162 www.viatran.com
More informationSonic Ruptor 400. User Manual
Sonic Ruptor 400 User Manual Data herein has been verified and validated. It is believed adequate for the intended use of the instrument. If the instrument or procedures are used for purposes over and
More informationR & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.
R & D SPECIALTIES 2004, by R & D Specialties, Inc. All Rights Reserved. No part of this document may be copied or reproduced in any form or by any means without the prior written permission of R & D Specialties.
More informationPRO I Series CAPACITANCE PROBE
Price $5.00 PRO I Series CAPACITANCE PROBE OPERATING INSTRUCTIONS PLEASE READ CAREFULLY TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 1.0 INTRODUCTION... 4 2.0 APPLICATIONS... 4 3.0 INSTALLATION... 4 3.1
More informationFAZE 800 FT PRO USER MANUAL. Version: 1.2. ROBE Lighting s.r.o. Czech Republic
FAZE 800 FT PRO USER MANUAL Version: 1.2 ROBE Lighting s.r.o. Czech Republic www.robe.cz FAZE 800 FT PRO Table of contents 1. Introduction 4 2. Cautions 4 3. Opening the package and inspecting the machine
More informationMFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company
MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System User s Manual D-M-E Company D-M-E Company MFA-0801 & MFA-1201 Page 1 Copyright D-M-E Company 1995. All rights reserved. D-M-E
More informationUser Guide. Control Box. RoscoLED TM.
RoscoLED TM Control Box User Guide This guide applies to the following RoscoLED Control Box models: RoscoLED Control Box 300W/Static White (293 22250 0000) RoscoLED Control Box 400W/VariWhite (293 22260
More informationCubePro. Main PCB Replacement Guide. Prosumer 3D Printer. Original Instructions
CubePro Prosumer 3D Printer Main PCB Replacement Guide Original Instructions 1 INTRODUCTION COPYRIGHT 2014 by All rights reserved. This document is subject to change without notice. This document is copyrighted
More informationMODEL 245 / 345 DigiComp
MODEL 245 / 345 DigiComp PRESSURE TRANSMITTER INSTALLATION DATA MANUAL 3829 Forest Parkway, Suite 500 Wheatfield, NY 14120 Toll Free: 1-800-688-0030 International: 716-629-3800 Fax: 716-693-9162 www.viatran.com
More informationLEGA ENERGY ELECTRONIC RELAY VOLTAGE STABILIZER VA USER MANUAL
RELAY VOLTAGE STABILIZER 500 1000 2000 3500 5000 VA USER MANUAL 1- By-pass manuel switch 2- RJ-11 jacks 3- Power signal lamp 4- Stabiliser indication 5- Output plugs 6- Input plug LEGA ENERGY ELECTRONIC
More informationPCM-7140 Pulsed Current Source Operation Manual
PCM-7140 Pulsed Current Source Operation Manual Directed Energy, Inc. 1609 Oakridge Dr., Suite 100, Fort Collins, CO 80525 (970) 493-1901 sales@ixyscolorado.com www.ixyscolorado.com Manual Document 7650-0031
More informationPS8 - II. Professional Power Sequencer. User s Manual
PS8 - II Professional Power Sequencer User s Manual IMPORTANT SAFETY INSTRUCTIONS READ FIRST This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure.
More informationEmerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.
Liebert PSA iton User Manual Version: V2.8 Revision date: November 14, 2005 Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or
More informationUser's Guide. Model High Precision Quad Output DC Power Supply
User's Guide Model 382270 High Precision Quad Output DC Power Supply Introduction Congratulations on your purchase of the Extech 382270 DC Power Supply. The Model 382270 can be used for many applications
More informationModel HM-535 Power Supply Installation and Service Instructions
Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS
More informationOwner s Instruction Manual
Owner s Instruction Manual Advanced Healthcare Telephone Model 5150 Contents IMPORTANT SAFETY INSTRUCTIONS...3 BOX CONTENTS...4 FEATURES...4 ON/OFF SWITCH...4 DIAL BUTTONS...4 RECEIVER VOLUME CONTROL...4
More informationUSER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power
Critical Power USER MANUAL Uninterruptible Power Supply Line-interactive VCL Series UPS 400 600 800 1000 1500 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland
More information4-20mA Display. Installation and Operation Manual. Rev 4/3/2019 Part #
4-20mA Display Installation and Operation Manual Rev 4/3/2019 Part # 12050769 Table of Contents DOCUMENTATION CONVENTIONS... 2 Section 1: System Description... 3 Function and Theory... 3 Section 2: System
More informationPDS100 Programmable Dispensing System SAFETY INSTRUCTIONS
PDS100 Programmable Dispensing System INSTRUCTION MANUAL SAFETY INSTRUCTIONS Before using any Fluid Metering, Inc. product read the following safety instructions as well as specific product specifications
More informationDP-222Q Color Video Door Phone Manual
DP-222Q Color Video Door Phone Manual * has 6 LEDs for nighttime operation Remotely and securely talk to visitors and unlock doors, gates, etc. from the Easily connect a secondary * Simple 2-wire connection
More informationOperation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.
Concorde 600 Power Supply Operation Manual Cat.no. R10-1001011 *This instrument is intended for laboratory use only http://www.recenttec.com E-mail : support@recenttec.com Version 1.1 Packing List x 1
More informationSP6R Level Controller Operation Manual
SP6R Level Controller Operation Manual www.sjerhombus.com SP6R LEVEL CONTROLLER INTRODUCTION SJE-Rhombus, an industry leader in water and wastewater pump controls, introduces the SP6R Level Controller.
More informationPRO II X Series CAPACITANCE PROBE
Price $5.00 PRO II X Series CAPACITANCE PROBE OPERATING INSTRUCTIONS PLEASE READ CAREFULLY 9250105.fm Rev. 2 TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 1.0 INTRODUCTION... 4 2.0 APPLICATIONS... 4 3.0
More informationSeries F75 Fail-Safe Module Installation, Operation and Maintenance Instructions
WCAIM2029 (Part 16022) Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions CAUTION: Flowserve recommends that all products that must be stored prior to installation be stored
More informationThe power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.
The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings
More informationExplosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter
Installation, Operation & Maintenance Sheet Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter > Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2
More information1 Channel Strobe Controller ORDERCODE 40226
1 Channel Strobe Controller ORDERCODE 40226 Congratulations! You have bought a great, innovative product from Showtec. The Showtec Strobe Controller brings excitement to any venue. Whether you want simple
More informationDP-222Q Color Video Door Phone Manual
DP-222Q Color Video Door Phone Manual * has 6 LEDs for nighttime operation Remotely and securely talk to visitors and unlock doors, gates, etc. from the Easily connect an secondary * Simple 2-wire connection
More informationMAXIMA+ Series Rotary Level Indicator
MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE
More informationInstall Motor Controller User Manual
Property of Motion Laboratories, Inc. Install Motor Controller User Manual 2014 Motion Laboratories, Inc. Created By: Michael Shaw Approved By: John Coppolecchia Page: 1 Page: 2 2014 Motion Laboratories,
More informationManual No: Revision: D. Mag Retrofit Probe. Installation Guide
Manual No: 577013-791 Revision: D Mag Retrofit Probe Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties
More informationI/O Expansion Box Installation & Operator s Instruction Manual
I/O Expansion Box Installation & Operator s Instruction Manual May 2004 CTB Inc. Warranty I/O Expansion Box CTB Inc. Warranty CTB Inc. warrants each new Chore-Tronics product manufactured by it to be free
More informationInstruction Manual. M Pump Motor Controller. For file reference, please record the following data:
Instruction Manual M Pump Motor Controller For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your
More informationMDM 011-Z1 Regen Resistor
MDM 011-Z1 Regen Resistor Date of creation: 10.04.2017 Version date: 10.04.2017 Article number: 09-402-011-Z1-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax: 06274/4321-18
More informationDP-234Q (NTSC) DP-734Q (PAL) Hands-Free Video Door Phone Manual
DP-234Q (NTSC) DP-734Q (PAL) Hands-Free Video Door Phone Manual Screen image simulated. * has four LEDs for nighttime operation Remotely and securely talk to visitors and unlock doors, gates, etc. from
More informationS82S (3/7.5-W Models)
Switch Mode Power Supply (3/7.5-W Models) CSM DS_E_4_3 Miniature DIN Rail Mounting DC-DC Power Supplies 65 mm depth enables mounting onto control panels with 100 mm depth. Inputs: 10.2 to 27.6 VDC (DC
More informationCO2 Controller Operating Instructions Models: RAD-0501, RAD-0501A, RAD-0501E 1. Product Description
CO2 Controller Operating Instructions Models: RAD-0501, RAD-0501A, RAD-0501E 1. Product Description RAD-0501 Greenhouse Mode: Controls CO2 generator or regulator to increase CO2 levels during daylight
More informationLine Interactive 1000VA/1400VA/2000VA Uninterruptible Power System
USER MANUAL Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System 614-06762-00 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for Line Interactive
More informationSIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS
SEE SAFETY WARNING ON PAGE 6 SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY IS DESIGNED TO BE USED WITH KBAC 3G SERIES DRIVES ONLY KBAC 3G SERIES MODELS CONTAIN THE "(3G)" DESIGNATOR ON THE PRODUCT LABEL
More informationOperating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage
Operating and Installation Manual EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Type EM-TRF-USV for 230 V AC mains voltage; provides uninterruptible power supply (UPS) The art of handling
More informationUSP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10
UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for
More information3M Duplex Polishing Machine 6851-E with Universal Dual Holder Instructions
3M Duplex Polishing Machine 6851-E with Universal Dual Holder Instructions Safety Information Read, understand and follow all safety information contained in these user instructions prior to use of the
More informationPRO REMOTE 25 CAPACITANCE PROBE OPERATING INSTRUCTIONS READ THOROUGHLY BEFORE INSTALLING EQUIPMENT Jamieson Equipmen toll free 800
PRO REMOTE 25 CAPACITANCE PROBE OPERATING INSTRUCTIONS READ THOROUGHLY BEFORE INSTALLING EQUIPMENT TABLE OF CONTENTS GENERAL SPECIFICATIONS...3 1.0 INTRODUCTION...4 2.0 APPLICATIONS...4 3.0 INSTALLATION...4
More informationInstallation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2
Supersedes 6/2015 Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2 XXCFXXX10-DIN Contents Description Page 1.0 Setup...2 1.1 Before Installation...2 1.2 Installation...3 For AC Applications...3
More informationPHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL
PHASETRONICS Specialists EP1 Series Power Control Single Phase SCR 10-50 Amps OPERATION & SERVICE MANUAL Phasetronics, Inc. P.O. Box 5988 1600 Sunshine Drive Clearwater, FL 33765 (727)573-1900 FAX(727)573-1803
More informationMAXIMA + Series ROTARY LEVEL CONTROL
Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A
More informationDDE-B Robot station Ref. DDRE-B
DDE-B Robot station Ref. DDRE-B Packing List Features The following items should be included: USB-A connector 2.8 Color TFT screen 2 Tools Control Unit... 1 unit Ref. DDE-1B (120V) DDE-2B (230V) DDE-9B
More informationLINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.
LINE VOLTAGE TESTER USER S MANUAL CT101 Please read this manual carefully and thoroughly before using this product. KEY FEATURES Visual indication of AC or DC voltage Easy to use approved Safe for CAT
More informationInstallation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.
Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable
More informationEMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina
Progressive Industries Warranty Progressive warrants its products are free from defects in materials and workmanship for a period of three years. This is in lieu of all other warranties, obligations, or
More informationInstruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C
Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and
More informationAirPro Surveyor 2 Manual
AirPro Surveyor 2 Manual AirPro Surveyor Specifications Table of Contents Size 3/8 x 7 1/2 x 4 3/8 Weight 4.6 lbs. 2094 g Dynamic Range 1-1000 ml/min. total flow/constant flow Flow Capacity (8 Hrs.) 1000
More informationLevCon. Liquid Level Indicator / Controller DIAL-SJE ( )
LevCon Liquid Level Indicator / Controller 1-888-DIAL-SJE (1-888-342-5753) www.sjerhombus.com LEVCON CONTROLLER INTRODUCTION The LevCon set point level controller is a self-contained microprocessor controlled
More informationEPS Power Supply
EPS - 600 Power Supply Installation and Operation Manual Version 1.0 *This instrument is intended for laboratory use only Index A. Important Notice ----------------------------------------------------------------
More informationDRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria
DRT-301 A/D Three phase four wire DIN rail energy meter (Seven modules) 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Structure Diagram 1.7 Dimensions
More informationCRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)
CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K) CRM Applications CRM includes a control relay box and a power supply; additional
More informationD-Pack 6 Classic ORDERCODE 50315
D-Pack 6 Classic ORDERCODE 50315 Congratulations! You have bought a great, innovative product from Showtec. The Showtec D-Pack 6 Classic brings excitement to any venue. Whether you want simple plug-&-play
More informationDC100 Digital Dispenser Operating Manual
DC100 Digital Dispenser Operating Manual 2015 Fisnar Phone: (262)253-8600 E-mail: info@fisnar.com Table of Contents Product Safety Statement 4 Specifications 6 Accessories 6 External Controls 7 Machine
More informationControl. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V Voltage 1, 2, 3 Pump Piston (D, E, F, G)
Part B, Section 2 Model This section covers the following unit configurations. 3100V 3400V 3500V Voltage 1, 2, 3 Pump Piston (D, E, F, G) Manifold 4-Port (A) 6-Port (B or C) 2-Port (S or T) Vista Temperature
More information2-Way Wireless I/O Expander Installation Guide
2-Way Wireless I/O Expander Installation Guide For more detailed information please refer to the iconnect Installer Manual provided on our website: www.electronics-line.com Table of Contents 1. Introduction...
More informationINSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES
INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-6B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual
More informationPDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL
PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL 1 IMPORTANT SAFETY INSTRUCTION READ FIRST This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure-voltage
More informationChore-Tronics Mobile Server
Chore-Tronics Mobile Server Installation & Operator s Instruction Manual Contact your nearby Chore-Time distributor or representative for additional parts and information. Chore-Time Group A division of
More informationipad Charge & Sync Cart Model MCC2 ipad Cart 430-MCC2-User Manual-010 Is a Registered Trademark of Apple Inc. ipad
ipad Charge & Sync Cart Model MCC2 ipad Cart ipad Is a Registered Trademark of Apple Inc. 430-MCC2-User Manual-010 1. ipad Cart Specifications MCC2 Mobile Charge & Sync Cart Extra Drawer Reserved space
More information3.5 TFT LCD CCTV Service Viewer with Wristband LCD35SV
User Manual 3.5 TFT LCD CCTV Service Viewer with Wristband LCD35SV LCD35SV is a type of product that summarizes views of first-line safety engineers and it is developed specially for technical personnel
More informationSKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB
SKIVING MACHINE ASSK2 MAINTENANCE & INSTRUCTIONS MANUAL A. WARRANTY AND RESPONSIBILITY Warranty: It's the supplier's responsibility to guarantee the conformity of the product, assuring that it's manufactured
More informationRAINPROOF* COLOR CAMERA SECURITY SYSTEM
RAINPROOF* COLOR CAMERA SECURITY SYSTEM Model 91202 ASSEMBLY AND OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at: http://www.harborfreight.com Copyright 2004 by
More informationInstallation Instructions
50ES, 50EZ, 50GL, 50GS, 50GX, 50JS, 50JX, 50JZ, 50SD, 50SZ, 50VL, 50VT, 50XP, 50XZ 601A, 602A, 602B, 604A, 604B, 604D, 607C, 701A, 702A, 702B, 704A, 704B, 704D, 707C PA1P, PA2P, PA3P, PH1P, PH2P, PH3P
More informationPRO-1250D CT MID DIN rail three phase four wire energy meter.
PRO-1250D CT MID DIN rail three phase four wire energy meter. 1.1 Safety instructions 1.2 Foreword 1.3 MID certificate 1.4 Performance criteria 1.5 Specifications 1.6 Basic errors 1.7 Description 1.8 Dimensions
More informationTorque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24
Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24 Section Page Introduction 1 Materials Provided 1 I) Safety Instructions 1 A) Inverter Safety Instructions 1 B) Battery Safety
More informationSurge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL
LoadTrack LTL Surge Protective Devices Installation, Operation and Maintenance Manual P.O. Box 3760 Winter Park, FL 32790 USA TEL: 800-647-1911 www.tpssurge.com LOADTRACK LTL INSTALLATION, OPERATION AND
More informationModel 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit
More informationMFP5G, MFP8G, & MFP12G D-M-E Smart Series Mainframes
MFP5G, MFP8G, & MFP12G D-M-E Smart Series Mainframes User s Manual D-M-E Company D-M-E Company MFP5G, MFP8G, MFP12G Page 1 Copyright D-M-E Company 1999. All rights reserved. D-M-E Company products are
More informationGas Cooling Accessory
TA Instruments 109 Lukens Drive New Castle, DE 19720 Thermal Analysis & Rheology A SUBSIDIARY OF WATERS CORPORATION Gas Cooling Accessory Operator's Manual PN 991426.001 Rev. D (Text and Binder) PN 991426.002
More informationPIM-Mini Pulsed Current Source Operation Manual
PIM-Mini Pulsed Current Source Operation Manual Directed Energy, Inc. 1609 Oakridge Dr., Suite 100, Fort Collins, CO 80525 (970) 493-1901 sales@ixyscolorado.com www.ixyscolorado.com Manual Document 7650-0007
More informationINSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES
INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-7B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual
More informationDISCONTINUED PRODUCT DISCONTINUED PRODUCT
Important Safety Instructions This manual contains important safety instructions that should be followed during the installation and maintenance of this product. Please read this manual thoroughly before
More informationPRO-75 SERIES. User manual
PRO-75 SERIES DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
More informationMCP-25/MS Control. Manual Number: MC051 Revision Date: 5/2013 Software Version: C074 05/02/13
MCP-25/MS Control Manual Number: MC051 Revision Date: 5/2013 Software Version: C074 05/02/13 2013 Valco Cincinnati, Inc. All Rights Reserved This manual is provided with the MCP-25/MS Control and may be
More informationInstallation Notes TII Model 341 Protector
Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow
More informationStart Here. All-in-One Printer. Print Copy Scan
Start Here All-in-One Printer Print Copy Scan Note: A USB 2.0 cable is required to connect your Kodak All-in-One printer to your Windows or Macintosh OS computer. Available in the Kodak online store or
More informationBS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL
BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL Issue 2011 ASL Intercom BV DESIGNED & MANUFACTURED BY: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Tel: +31 (0)30 2411901 Fax: +31 (0)30
More informationService Instructions. Conductor 420
Service Instructions Conductor 420 Listed, File No. E195547 Input: 480 VAC, 50/60 HZ. (Operating range 380-480 VAC) 20 AMP MAX OUTPUT W/25 AMP FUSE Output: 0-90% of Input Voltage Table of Contents General
More informationInstallation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE
IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL
More informationLXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual
LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp Single phase two wire DIN rail energy meter (One module) 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic
More informationINSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES
INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-4B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual
More informationFNet Repeater Installation & Operator s Instruction Manual
FNet Repeater Installation & Operator s Instruction Manual October 2004 CTB Inc. Warranty FNet Repeater CTB Inc. Warranty CTB Inc. warrants each new Chore-Tronics product manufactured by it to be free
More informationINSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES
INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-5B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual
More informationTornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller
Tornado F-5 Motor Backspin Detect Relay And Probe For F-5 Motor Controller Tornado F-5 Motor Backspin Detection Relay And Probe Revision 8.1 Change Log: Rev 8.1 Apr 24 2012 JNesbitt@GPS-US.co GPS updates
More informationSOLARIMMERSION IV Advanced Installation Manual v1.9
SOLARIMMERSION IV Advanced Installation Manual v1.9 1 Contents 1. Overview 2. Technical Specifications 3. Installation Mounting Electrical Installation Clamp Installation Wiring Diagrams 4. Installation
More informationVSD-1MC MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override
MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override Varifan 3 4 5 6 7 MANUAL 2 8 1 OFF 10 9 AUTO MANUAL SPEED Installation / User s Guide This guide will inform the electrician on proper wiring
More informationUser Manual for the Antari M-1 Mobile Fog Machine. Congratulations on the purchase of your new ANTARI M-1 Mobile Fog Machine
User Manual for the Antari M-1 Mobile Fog Machine Congratulations on the purchase of your new ANTARI M-1 Mobile Fog Machine Save and read these instructions Bitte lesen Sie und sichern Sie diese Anweisungen
More informationThe identified danger could cause physical and property damage.
Samba OPLC SM35-J-T20 Installation Guide The Unitronics SM35-J-T20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder Inputs 8 Transistor
More informationPTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions
, Equipment protection fuse with Ex mb II C Gb approval Geräteschutzsicherung mit Zulassung Ex mb II C Gb Fusible de protection d appareil avec homologation Ex mb II C Gb Example / Beispiel / Exemple:
More informationInstruction Manual Standard Multi-Position Stirrers Advanced Multi-Position Stirrers
Instruction Manual Standard Multi-Position Stirrers Advanced Multi-Position Stirrers Table of Contents Package Contents.............. 1 Warranty.............. 1 Installation.............. 2 Maintenance
More informationProgressive Industries, Inc. EMS Electrical Management System
Progressive Industries, Inc. EMS Electrical Management System Complete Installation Guide and Operating Instructions for: Model EMS-LCHW50 Rated at 240V/50A Manufactured by: Progressive Industries, Inc.
More informationAgilent Technologies E5339A 38-Pin Low-Voltage Probe
Agilent Technologies E5339A 38-Pin Low-Voltage Probe Installation Note The 38-pin low-voltage probe provides a convenient way to connect two Agilent Technologies logic analyzer probe cables to a small
More informationPRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5
PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5 1 Safety instructions...3 2 Foreword...4 3 CE certificates...5 4 MID certificate...7 5 Performance criteria...8 6 Specifications...8
More information