1 SMB 3.0 Performance Dan Lovinger Principal Architect Microsoft
2 Overview Stats & Methods Scenario: OLTP Database Scenario: Cluster Motion SMB 3.0 Multi Channel Agenda: challenges during the development of SMB 3.0 during the development of Windows Server 2012 (and Windows 8)
3 Summary Statistics Then there is the man who drowned crossing a stream with an average depth of six inches. W.I.E. Gates (?) 3
4 Transactions/s Starting Point Metric v. Time 6000 Transaction Rate Time (s) All sorts of interesting things afoot!
5 Transactions/s Average Transaction Rate Average Time (s) Classic problem completely different behaviors have the same average understates steady state hides very interesting behavior Performance is often in the variation How often how consistently where are the outliers to analyze
6 # of Samples Distribution 60 Distribution : Transaction Rate Average in bucket Transactions/s Histogram / Distribution How often was the system running this fast? Note that data must be resampled into buckets In this example buckets are 20 transactions/s wide average located in the [ ) transactions/s bucket, with 21 samples
7 # of Samples Standard Deviation 60 Distribution : Transaction Rate σ Average +σ Transactions/s Familiar first approximation here, +/ transactions/s Strong meaning if the type of distribution is known Gaussian / Normal the classic Bell Curve - ~34% to each side which this is not Spans >90% of the total distribution, here
8 # of Samples Median Distribution : Transaction Rate Average Median Transactions/s The mid-point of all of the data points 50% higher 50% lower 50 th Percentile Coincidentally matches the peak of this distribution transactions/s
9 # of Samples Percentiles 60 Distribution : Transaction Rate Transactions/s Median Percentage of the dataset cut lines Relevant to guarantees of behavior / performance Median locates the center 10 s and 90 s No worse than / At least X, Y% of the time What makes sense for latency? Bandwidth?
10 # of Samples Percentiles Distribution : Transaction Rate Transactions/s -σ Median σ Looking back to standard deviation, it really didn t work. for a 30 minute real workload with a well defined steady state!
11 Percentile Cumulative Distributions 100% 90% 80% 70% Cumulative Distribution : Transaction Rate 60% 50% 40% 30% 20% 10% 0% Transactions/s Visualization of percentiles
12 Percentile OLTP 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% Transaction Rate - Cumulative Distribution OLTP Simulation - Full Run Transactions/s SMB SMB+ DAS Note: for this section, SMB and SMB+ refer to a before and after change, not a revision of the protocol. The issue was not in SMB and very specific to workload. See summary. 12
13 OLTP OLTP OnLine Transaction Processing Log File small-midsize sequential IO Database File(s) small random IO Fundamental dependency on the SMB 3.0 feature set for continuously available connections to the database content New workloads new problems for an implementation
14 Simulated OLTP Hardware Configuration CPU Type Memory Amount Network Type Client Server 2 sockets with Ghz (12 cores total) 36 GiB Onboard 1GbE network interface Number of Network Links Storage Adapter Storage N/A N/A 1 x 1GbE 1 Fibre Channel Adapter 2x 4Gb/s connectivity 14x 10KRPM HDD RAID0 14
15 Simulated OLTP Hardware Configuration Client 1 Gb Ethernet 2x4Gb Fibre Channel Server DAS SMB 14 Disk RAID10 15
16 18 Years Later The Write Bubble NT Filesystem Lingo: Valid Data Length Offset in file to which user data has written data Allows efficient physical zeroing fully allocated files Code sharing from the FAT implementation May 1994 clever trick for VDL extension Nov 1994 ported over with a slight mislocation Causal requirements Simultaneous Read/Write, Async, NonCached IO to the same file No other workload affected! 16
17 Average Queue Length Simulated OLTP Average Disk Queue Length Distribution SMB SMB+ DAS Disk Queue Length 17
18 Percentile Simulated OLTP 100% 90% 80% 70% 8KiB Random IO/s Cumulative Distribution SMB v. DAS Windows 2008 R2 RTM 60% 50% 40% 30% SMB SMB+ DAS 20% 10% 0% IO Operations per Second 18
19 Samples Simulated OLTP SMB+ Client v. Server DAS Latency Windows 2008 R2 RTM Latency (ms) 500us Client Read Server Read Client Write Server Write Percentile Read Shift (%) Write Shift (%) Read Shift (us) Write Shift (us) 10% 13% 7% % 6% 4% % 3% 2% % 2% 1% % 1% 1%
20 Percentile Simulated OLTP 100% 90% 80% 70% 8KiB Random IO/s Cumulative Distribution SMB v. DAS Windows Server % 50% 40% Methodology Effect SMB SMB+ 30% DAS 20% 10% 0% IO Operations per Second 20
21 Samples Simulated OLTP SMB+ Client v. Server DAS Latency Windows Server Latency (ms) 410us Client Read Server Read Client Write Server Write Percentile Read Shift (%) Write Shift (%) Read Shift (us) Write Shift (us) 10% 12% 6% % 5% 4% % 2% 1% % 1% 0% % 0% 0%
22 OLTP Hardware Configuration CPU Type Memory Amount Network Type Client Server 2 sockets with Ghz (8 cores total) 24 GiB Onboard 1GbE network interface Number of Network Links Storage Adapter Storage N/A N/A 1 x 1GbE 1 Fibre Channel Adapter 2x 4Gb/s connectivity 24x 10KRPM HDD: 2x 10 HDD RAID0 (DB) 2 HDD RAID0 (LOG) 22
23 OLTP Hardware Configuration Client 1 Gb Ethernet 2x4Gb Fibre Channel Server DAS SMB 2x 10 Disk RAID0 (Data) 2 Disk RAID0 (Log) 23
24 Percentile OLTP 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% Transaction Rate - Cumulative Distribution OLTP Simulation - Full Run Transactions/s SMB SMB+ DAS Full result is intuitively close Median 4270 transactions/s Mean 3920 transactions/s 4Gb v. 1Gb effect? 24
25 Transactions/s OLTP First Correction 7000 SMB v. DAS Transaction Rate - Ingest SMB+ Tps DAS Tps Time (seconds) 25
26 Million Bytes/s OLTP First Correction 300 SMB v. DAS Bandwidth - Ingest SMB+ Read Bytes DAS Read Bytes Time (seconds) 26
27 Percent of Total OLTP After First Correction Transaction Rate - Cumulative Distribution Post Ingest 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% SQL Transactions/s SMB+ DAS Far closer! 27
28 Transactions/s OLTP Second Correction 7000 Transaction Rate To Equal Work Steady State GB OLTP Log SMB+ DAS Time (seconds) 28
29 Million Bytes/s OLTP Second Correction 300 SMB v. DAS Transition Read Bandwidth To Equal Work Steady State GB OLTP Log Gb SMB+ DAS Time (seconds) 29
30 Percent of Total OLTP After Second Correction 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% Transaction Rate - Cumulative Distribution Steady State - Work Matched SQL Transactions/s SMB+ DAS Again intuitive random IO bandwidth << 1Gb Only -3.0% performance relative to DAS over final 19 minutes of the run (+33s) 1Gb Ethernet very nearly meets 4Gb FC Log Volume Data Volumes DAS SMB2 DAS SMB2 Mean IO Operations/s (-5.4%) (-5.4%) Median (-3.7%) (-3.6%) 80 th (-3.1%) (-3.1%) 90 th (-3.0%) (-3.1%) 95 th (-3.1%) (-3.0%) 30
31 Percennt of Total # IOs OLTP More than 4/8 KiB Database File IO Size 10,000,000 1,000,000 8iKB 100,000 10,000 1, Read Write IO Size (KiBytes) Database File IO - Bytes Transferred by IO 100% 90% 80% 70% 60% Note: 49% 50% IO Size (KiBytes) Read Write 31
32 # IOs (Thousands) OLTP Log Matters 1000 Log Write Size IO Size (KiBytes) 32
33 OLTP Understanding workload is critical for performance Enabling new workloads is both a protocol and platform effort Windows 7 / 2008 R2 KB Mixed Read/Write Async NonCached IO Same File otherwise, no issue. It took a true database to hit it. No other workload affected!
34 Cluster Motion SMB 3.0 Continuous Availbility Cluster Implementations should look at performance of essential cluster management operations Bet: scale of clustered resources will rise significantly, relative to pre-smb 3.0 services Planned v. Unplanned Motion Goal: define the time budget.
35 Cluster Hardware Configuration CPU Type Memory Amount Network Type Number of Network Links Storage Adapter Storage Client Server 2 sockets with Ghz (4 cores total) 4GiB Onboard 1GbE network interface (Cluster Network) N/A N/A 1 x 1GbE 1 Fibre Channel Adapter 4Gb/s connectivity 120x 10KRPM HDD Enterprise FC Array Slow & Old! 35
36 OLTP Hardware Configuration 36
37 Cluster Motion Resource Group Container of objects representing the file service High scale on disks depending on implementation HW/SW Volume Smaller scale on total number of groups Config: 3 FS Groups, 40 disks each Net Name IPv4 IPv6 File Server Disk 2 Disk 1 Disk N 37
38 Cluster Motion Resource Control Manager handles the process for Windows, generalizable to other platforms Cluster log follows the state changes, similar to: PS> Get-ClusterLog RCM Offline Online WaitingToGoOffline OfflineCallIssued OfflinePending OfflineSavingCheckpoints RCM Online Offline WaitingToComeOnline OnlineCallIssued OnlinePending Online Offline b cc::2011/08/25-00:23: INFO [RCM] TransitionToState(IP Address ) OfflineCallIssued-->OfflineSavingCheckpoints.
39 Clock Time (seconds) Cluster Motion 60 Offline -> Online (Disks) - Initial
40 60000 Offline -> Online (NonDisk) Initial
41 Cluster Motion Crossover Ethernet cluster network Simultaneous disconnect of crossover network and loss of node (e.g., node power loss) Unplanned motion 80s delay Windows 2008 R2 KB
42 Clock Time (seconds) Cluster Motion - Disks 12 Hard Disk Offline - Initial Disks in 3 resource groups 42
43 Cluster Motion - Disks Hard disk resource internals Remove of FSCTL_LOCK_VOLUME prior to dismount Remove of timer used to simplify async completion of PR reservation release Remove of soft guard between IOCTL_OFFLINE_VOLUME and the online process Reduce conservative polling interval for disk onlines
44 Clock Time (seconds) Cluster Motion - Disks 12 Hard Disk Offline - Final Disks in 3 resource groups 44
45 Clock Time (seconds) Cluster Motion - Final 30 Offline -> Online (Disks) - Final Disks in 3 resource groups
46 Clock Time (seconds) Cluster Motion - Final 30 Offline -> Online (NonDisks) Final OnlinePending OnlineCallIssued WaitingToComeOnline Offline OfflineSavingCheckpoints OfflinePending OfflineCallIssued WaitingToGoOffline Online 46
47 Cluster Motion Summary Large outlier in unplanned loss removed Relative: ~80% faster at scale Absolute: sub-10s motion at scale Larger or smaller than possible reality? Implementers Look at your platform repeat under loads
48 Multichannel Goals Expand session beyond a single TCP stream / CPU Availability / Network fault tolerance Make the SMB2 protocol resilient to interface, link or switch failures. Move link awareness higher up the stack to enable more intelligent decision making. Augment NIC teaming at the network layer. Keep fallback paths ready, prioritize available links. React quickly to changes to network availability. Performance utilize the available resource 48
49 Multichannel - Terminology Channel: underlying transport connection Session: authenticated user context. Session Binding: map Session Channel N:N relationship User A User B Sessions Bindings TCP TCP RDMA Channels 49
50 Test Hardware Configuration CPU Type Memory Amount Network Type Client Server 2 sockets with Ghz (12 cores total) 48 GiB 2 network interface adapter cards Each card has 2 10GbE interfaces Number of Network Links Storage Adapter Storage N/A N/A 4 x 10GbE 2 RAID Host Bus Adapters 6Gb/s SAS connectivity 12 3G SATA SSD / HBA 50
51 Test Hardware Configuration RAID0 12 SSDs RAID0 12 SSDs Client 10GbE Server 51
52 IOMETER Configuration I/O Size Number of Workers Queue Depth Total Queued Constant #Op Constant Bytes Scaled Bytes 52
53 MB/sec Server (Local) Baseline Server/Local Read Throughput Read Sequential Read Random IO Size (bytes) 53
54 MB/sec SMB 3.0 Client 10GbE Interface Scaling 6000 SMB 3.0 Client Interface Scaling - Throughput 1 x 10GbE 2 x 10GbE 4 x 10GbE IO Size (bytes) 54
55 MB/sec Server to SMB 3.0 Client Comparison Server/Local vs. Client Throughput Server/Local Throughput Client (4 x 10GbE) Throughput IO Size (bytes) 55
56 I/Os per second Priv CPU % Server to SMB 3.0 Client IOps Server/Local vs. Client IOps with CPU % Server/Local IOps Client (4 x 10GbE) Priv CPU Client (4 x 10GbE) IOps Server/Local Priv CPU 350, , , , , ,000 50, IO Size
57 Multi Channel Implementation Challenges Nodes with varying interface counts (1, 2, 4 NIC) Operation distribution across interfaces TCP v. RDMA TCP CPU is in the host RDMA CPU is primarily in the HCA Different connection scale points Performance goal: scale
58 Summary SMB 3.0 enables new workloads Workload demands will expose new issues in platforms and implementations be prepared New protocol features create new performance requiremens Downlevel platform improvements Windows 2008 R2 KB Cluster Unplanned with Crossover Ethernet Windows 7 / 2008 R2 KB Single-File Mixed Read/Write Async NonCached IO
WINDOWS SERVER 2012 ECHOSTREAMS FLACHESAN2
WINDOWS SERVER 212 ECHOSTREAMS FLACHESAN2 Dan Lovinger Windows File Server Performance April 213 1 INTRODUCTION This article presents a summary of the performance of the Windows Server 212 File Server
More informationHow Flash-Based Storage Performs on Real Applications Session 102-C
How Flash-Based Storage Performs on Real Applications Session 102-C Dennis Martin, President August 2016 1 Agenda About Demartek Enterprise Datacenter Environments Storage Performance Metrics Synthetic
More informationIsilon Performance. Name
1 Isilon Performance Name 2 Agenda Architecture Overview Next Generation Hardware Performance Caching Performance Streaming Reads Performance Tuning OneFS Architecture Overview Copyright 2014 EMC Corporation.
More informationLow Latency Evaluation of Fibre Channel, iscsi and SAS Host Interfaces
Low Latency Evaluation of Fibre Channel, iscsi and SAS Host Interfaces Evaluation report prepared under contract with LSI Corporation Introduction IT professionals see Solid State Disk (SSD) products as
More informationIdentifying Performance Bottlenecks with Real- World Applications and Flash-Based Storage
Identifying Performance Bottlenecks with Real- World Applications and Flash-Based Storage TechTarget Dennis Martin 1 Agenda About Demartek Enterprise Data Center Environments Storage Performance Metrics
More informationNAS for Server Virtualization Dennis Chapman Senior Technical Director NetApp
NAS for Server Virtualization Dennis Chapman Senior Technical Director NetApp Agenda The Landscape has Changed New Customer Requirements The Market has Begun to Move Comparing Performance Results Storage
More informationSoftware Defined Storage at the Speed of Flash. PRESENTATION TITLE GOES HERE Carlos Carrero Rajagopal Vaideeswaran Symantec
Software Defined Storage at the Speed of Flash PRESENTATION TITLE GOES HERE Carlos Carrero Rajagopal Vaideeswaran Symantec Agenda Introduction Software Technology Architecture Review Oracle Configuration
More informationApplication Acceleration Beyond Flash Storage
Application Acceleration Beyond Flash Storage Session 303C Mellanox Technologies Flash Memory Summit July 2014 Accelerating Applications, Step-by-Step First Steps Make compute fast Moore s Law Make storage
More informationRemoving the I/O Bottleneck in Enterprise Storage
Removing the I/O Bottleneck in Enterprise Storage WALTER AMSLER, SENIOR DIRECTOR HITACHI DATA SYSTEMS AUGUST 2013 Enterprise Storage Requirements and Characteristics Reengineering for Flash removing I/O
More informationEvaluation Report: Improving SQL Server Database Performance with Dot Hill AssuredSAN 4824 Flash Upgrades
Evaluation Report: Improving SQL Server Database Performance with Dot Hill AssuredSAN 4824 Flash Upgrades Evaluation report prepared under contract with Dot Hill August 2015 Executive Summary Solid state
More informationOracle Platform Performance Baseline Oracle 12c on Hitachi VSP G1000. Benchmark Report December 2014
Oracle Platform Performance Baseline Oracle 12c on Hitachi VSP G1000 Benchmark Report December 2014 Contents 1 System Configuration 2 Introduction into Oracle Platform Performance Tests 3 Storage Benchmark
More informationSUPERMICRO, VEXATA AND INTEL ENABLING NEW LEVELS PERFORMANCE AND EFFICIENCY FOR REAL-TIME DATA ANALYTICS FOR SQL DATA WAREHOUSE DEPLOYMENTS
TABLE OF CONTENTS 2 THE AGE OF INFORMATION ACCELERATION Vexata Provides the Missing Piece in The Information Acceleration Puzzle The Vexata - Supermicro Partnership 4 CREATING ULTRA HIGH-PERFORMANCE DATA
More informationIBM V7000 Unified R1.4.2 Asynchronous Replication Performance Reference Guide
V7 Unified Asynchronous Replication Performance Reference Guide IBM V7 Unified R1.4.2 Asynchronous Replication Performance Reference Guide Document Version 1. SONAS / V7 Unified Asynchronous Replication
More informationEvaluation of the Chelsio T580-CR iscsi Offload adapter
October 2016 Evaluation of the Chelsio T580-CR iscsi iscsi Offload makes a difference Executive Summary As application processing demands increase and the amount of data continues to grow, getting this
More informationPRESENTATION TITLE GOES HERE
Performance Basics PRESENTATION TITLE GOES HERE Leah Schoeb, Member of SNIA Technical Council SNIA EmeraldTM Training SNIA Emerald Power Efficiency Measurement Specification, for use in EPA ENERGY STAR
More informationComparison of Storage Protocol Performance ESX Server 3.5
Performance Study Comparison of Storage Protocol Performance ESX Server 3.5 This study provides performance comparisons of various storage connection options available to VMware ESX Server. We used the
More informationEvaluating SMB2 Performance for Home Directory Workloads
Evaluating SMB2 Performance for Home Directory Workloads Dan Lovinger, David Kruse Development Leads Windows Server / File Server Team 2010 Storage Developer Conference. Microsoft Corporation. All Rights
More informationAccelerate Applications Using EqualLogic Arrays with directcache
Accelerate Applications Using EqualLogic Arrays with directcache Abstract This paper demonstrates how combining Fusion iomemory products with directcache software in host servers significantly improves
More informationHyperScalers JetStor appliance with Raidix storage software
HyperScalers JetStor appliance with Raidix storage software HyperScalers Pty Ltd. Conducted at HyperScalers Proof of Concept (PoC) Lab 24 th Aug 2016 Table of Contents 1. Executive Summary... 3 2. Introduction...
More informationCloudian Sizing and Architecture Guidelines
Cloudian Sizing and Architecture Guidelines The purpose of this document is to detail the key design parameters that should be considered when designing a Cloudian HyperStore architecture. The primary
More informationExtremely Fast Distributed Storage for Cloud Service Providers
Solution brief Intel Storage Builders StorPool Storage Intel SSD DC S3510 Series Intel Xeon Processor E3 and E5 Families Intel Ethernet Converged Network Adapter X710 Family Extremely Fast Distributed
More informationImplementing SQL Server 2016 with Microsoft Storage Spaces Direct on Dell EMC PowerEdge R730xd
Implementing SQL Server 2016 with Microsoft Storage Spaces Direct on Dell EMC PowerEdge R730xd Performance Study Dell EMC Engineering October 2017 A Dell EMC Performance Study Revisions Date October 2017
More informationEvaluation of Chelsio Terminator 6 (T6) Unified Wire Adapter iscsi Offload
November 2017 Evaluation of Chelsio Terminator 6 (T6) Unified Wire Adapter iscsi Offload Initiator and target iscsi offload improve performance and reduce processor utilization. Executive Summary The Chelsio
More informationLow-Overhead Flash Disaggregation via NVMe-over-Fabrics Vijay Balakrishnan Memory Solutions Lab. Samsung Semiconductor, Inc.
Low-Overhead Flash Disaggregation via NVMe-over-Fabrics Vijay Balakrishnan Memory Solutions Lab. Samsung Semiconductor, Inc. 1 DISCLAIMER This presentation and/or accompanying oral statements by Samsung
More informationNVMFS: A New File System Designed Specifically to Take Advantage of Nonvolatile Memory
NVMFS: A New File System Designed Specifically to Take Advantage of Nonvolatile Memory Dhananjoy Das, Sr. Systems Architect SanDisk Corp. 1 Agenda: Applications are KING! Storage landscape (Flash / NVM)
More informationBenchmarking Enterprise SSDs
Whitepaper March 2013 Benchmarking Enterprise SSDs When properly structured, benchmark tests enable IT professionals to compare solid-state drives (SSDs) under test with conventional hard disk drives (HDDs)
More informationEstimate performance and capacity requirements for Access Services
Estimate performance and capacity requirements for Access Services This document is provided as-is. Information and views expressed in this document, including URL and other Internet Web site references,
More informationAnil Vasudeva IMEX Research. (408)
Architecting Next Generation Enterprise Network Storage Anil Vasudeva Research (408) 268-0800 vasudeva@imexresearch.com 2000-2004 Research All rights Reserved Reproduction prohibited, without written permission
More informationVMware vsan 6.0 Performance First Published On: Last Updated On:
First Published On: 07-20-2016 Last Updated On: 07-20-2016 1 Table of Contents 1. Executive Summary 1.1.Executive Summary 2. Introduction 2.1.Overview 3. vsan Cluster Setup 3.1.Overview 3.2.Hybrid vsan
More informationLow-Overhead Flash Disaggregation via NVMe-over-Fabrics
Low-Overhead Flash Disaggregation via NVMe-over-Fabrics Vijay Balakrishnan Memory Solutions Lab. Samsung Semiconductor, Inc. August 2017 1 DISCLAIMER This presentation and/or accompanying oral statements
More informationStorage Update and Storage Best Practices for Microsoft Server Applications. Dennis Martin President, Demartek January 2009 Copyright 2009 Demartek
Storage Update and Storage Best Practices for Microsoft Server Applications Dennis Martin President, Demartek January 2009 Copyright 2009 Demartek Agenda Introduction Storage Technologies Storage Devices
More informationNetVault Backup Client and Server Sizing Guide 2.1
NetVault Backup Client and Server Sizing Guide 2.1 Recommended hardware and storage configurations for NetVault Backup 10.x and 11.x September, 2017 Page 1 Table of Contents 1. Abstract... 3 2. Introduction...
More informationHP SAS benchmark performance tests
HP SAS benchmark performance tests technology brief Abstract... 2 Introduction... 2 Test hardware... 2 HP ProLiant DL585 server... 2 HP ProLiant DL380 G4 and G4 SAS servers... 3 HP Smart Array P600 SAS
More informationEmulex LPe16000B 16Gb Fibre Channel HBA Evaluation
Demartek Emulex LPe16000B 16Gb Fibre Channel HBA Evaluation Evaluation report prepared under contract with Emulex Executive Summary The computing industry is experiencing an increasing demand for storage
More informationBest Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell EqualLogic Storage Arrays
Dell EqualLogic Best Practices Series Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell EqualLogic Storage Arrays A Dell Technical Whitepaper Jerry Daugherty Storage Infrastructure
More informationForget IOPS: A Proper Way to Characterize & Test Storage Performance Peter Murray SwiftTest
Forget IOPS: A Proper Way to Characterize & Test Storage Performance Peter Murray peter@swifttest.com SwiftTest Storage Performance Validation Rely on vendor IOPS claims Test in production and pray Validate
More informationAll Roads Lead to Convergence
All Roads Lead to Convergence Greg Scherer VP, Server and Storage Strategy gscherer@broadcom.com Broadcom Corporation 2 Agenda The Trend Toward Convergence over Ethernet Reasons for Storage and Networking
More informationDell PowerEdge R730xd Servers with Samsung SM1715 NVMe Drives Powers the Aerospike Fraud Prevention Benchmark
Dell PowerEdge R730xd Servers with Samsung SM1715 NVMe Drives Powers the Aerospike Fraud Prevention Benchmark Testing validation report prepared under contract with Dell Introduction As innovation drives
More informationNetVault Backup Client and Server Sizing Guide 3.0
NetVault Backup Client and Server Sizing Guide 3.0 Recommended hardware and storage configurations for NetVault Backup 12.x September 2018 Page 1 Table of Contents 1. Abstract... 3 2. Introduction... 3
More information10Gb iscsi Initiators
10Gb iscsi Initiators t June 2009 1 iscsi 10Gb Broadcom HBA vs. 10Gb Intel Software Initiator with I/OAT enabled 2 iscsi 10Gb Broadcom HBA vs. 10Gb Intel Software Initiator with I/OAT enabled Key findings
More informationSharePoint 2010 Technical Case Study: Microsoft SharePoint Server 2010 Enterprise Intranet Collaboration Environment
SharePoint 2010 Technical Case Study: Microsoft SharePoint Server 2010 Enterprise Intranet Collaboration Environment This document is provided as-is. Information and views expressed in this document, including
More informationStorage Protocol Offload for Virtualized Environments Session 301-F
Storage Protocol Offload for Virtualized Environments Session 301-F Dennis Martin, President August 2016 1 Agenda About Demartek Offloads I/O Virtualization Concepts RDMA Concepts Overlay Networks and
More informationIntroducing and Validating SNIA SSS Performance Test Suite Esther Spanjer SMART Modular
Introducing and Validating SNIA SSS Performance Test Suite Esther Spanjer SMART Modular Abstract SSS Performance Benchmarking Learning Objectives Get a good understanding of the various parameters that
More informationVirtualized SQL Server Performance and Scaling on Dell EMC XC Series Web-Scale Hyper-converged Appliances Powered by Nutanix Software
Virtualized SQL Server Performance and Scaling on Dell EMC XC Series Web-Scale Hyper-converged Appliances Powered by Nutanix Software Dell EMC Engineering January 2017 A Dell EMC Technical White Paper
More informationPerformance Lab Report & Architecture Overview Summary of SnapVDI Features and Performance Testing Using Login VSI
by American Megatrends, Inc. Performance Lab Report & Architecture Overview Summary of SnapVDI Features and Performance Testing Using Login VSI Table of Contents Executive Summary... 4 1. Introduction...
More informationOracle Performance on M5000 with F20 Flash Cache. Benchmark Report September 2011
Oracle Performance on M5000 with F20 Flash Cache Benchmark Report September 2011 Contents 1 About Benchware 2 Flash Cache Technology 3 Storage Performance Tests 4 Conclusion copyright 2011 by benchware.ch
More informationDesigning Next Generation FS for NVMe and NVMe-oF
Designing Next Generation FS for NVMe and NVMe-oF Liran Zvibel CTO, Co-founder Weka.IO @liranzvibel Santa Clara, CA 1 Designing Next Generation FS for NVMe and NVMe-oF Liran Zvibel CTO, Co-founder Weka.IO
More informationBest Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell Storage PS Series Arrays
Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell Storage PS Series Arrays Dell EMC Engineering December 2016 A Dell Best Practices Guide Revisions Date March 2011 Description Initial
More informationUpgrade to Microsoft SQL Server 2016 with Dell EMC Infrastructure
Upgrade to Microsoft SQL Server 2016 with Dell EMC Infrastructure Generational Comparison Study of Microsoft SQL Server Dell Engineering February 2017 Revisions Date Description February 2017 Version 1.0
More informationLearn Your Alphabet - SRIOV, NPIV, RoCE, iwarp to Pump Up Virtual Infrastructure Performance
Learn Your Alphabet - SRIOV, NPIV, RoCE, iwarp to Pump Up Virtual Infrastructure Performance TechTarget Dennis Martin 1 Agenda About Demartek I/O Virtualization Concepts RDMA Concepts Examples Demartek
More informationArchitecting For Availability, Performance & Networking With ScaleIO
Architecting For Availability, Performance & Networking With ScaleIO Performance is a set of bottlenecks Performance related components:, Operating Systems Network Drives Performance features: Caching
More informationDemystifying Storage Area Networks. Michael Wells Microsoft Application Solutions Specialist EMC Corporation
Demystifying Storage Area Networks Michael Wells Microsoft Application Solutions Specialist EMC Corporation About Me DBA for 7+ years Developer for 10+ years MCSE: Data Platform MCSE: SQL Server 2012 MCITP:
More informationPerformance Report: Multiprotocol Performance Test of VMware ESX 3.5 on NetApp Storage Systems
NETAPP TECHNICAL REPORT Performance Report: Multiprotocol Performance Test of VMware ESX 3.5 on NetApp Storage Systems A Performance Comparison Study of FC, iscsi, and NFS Protocols Jack McLeod, NetApp
More informationSurFS Product Description
SurFS Product Description 1. ABSTRACT SurFS An innovative technology is evolving the distributed storage ecosystem. SurFS is designed for cloud storage with extreme performance at a price that is significantly
More informationOptimizing Fusion iomemory on Red Hat Enterprise Linux 6 for Database Performance Acceleration. Sanjay Rao, Principal Software Engineer
Optimizing Fusion iomemory on Red Hat Enterprise Linux 6 for Database Performance Acceleration Sanjay Rao, Principal Software Engineer Version 1.0 August 2011 1801 Varsity Drive Raleigh NC 27606-2072 USA
More informationSession 201-B: Accelerating Enterprise Applications with Flash Memory
Session 201-B: Accelerating Enterprise Applications with Flash Memory Rob Larsen Director, Enterprise SSD Micron Technology relarsen@micron.com August 2014 1 Agenda Target applications Addressing needs
More informationAccelerating OLTP performance with NVMe SSDs Veronica Lagrange Changho Choi Vijay Balakrishnan
Accelerating OLTP performance with NVMe SSDs Veronica Lagrange Changho Choi Vijay Balakrishnan Agenda OLTP status quo Goal System environments Tuning and optimization MySQL Server results Percona Server
More informationBest Practices for SSD Performance Measurement
Best Practices for SSD Performance Measurement Overview Fast Facts - SSDs require unique performance measurement techniques - SSD performance can change as the drive is written - Accurate, consistent and
More informationEnterprise2014. GPFS with Flash840 on PureFlex and Power8 (AIX & Linux)
Chris Churchey Principal ATS Group, LLC churchey@theatsgroup.com (610-574-0207) October 2014 GPFS with Flash840 on PureFlex and Power8 (AIX & Linux) Why Monitor? (Clusters, Servers, Storage, Net, etc.)
More informationOn BigFix Performance: Disk is King. How to get your infrastructure right the first time! Case Study: IBM Cloud Development - WW IT Services
On BigFix Performance: Disk is King How to get your infrastructure right the first time! Case Study: IBM Cloud Development - WW IT Services Authors: Shaun T. Kelley, Mark Leitch Abstract: Rolling out large
More informationIBM FlashSystems with IBM i
IBM FlashSystems with IBM i Proof of Concept & Performance Testing Fabian Michel Client Technical Architect 1 2012 IBM Corporation Abstract This document summarizes the results of a first Proof of Concept
More informationdavidklee.net gplus.to/kleegeek linked.com/a/davidaklee
@kleegeek davidklee.net gplus.to/kleegeek linked.com/a/davidaklee Specialties / Focus Areas / Passions: Performance Tuning & Troubleshooting Virtualization Cloud Enablement Infrastructure Architecture
More informationCS370 Operating Systems
CS370 Operating Systems Colorado State University Yashwant K Malaiya Fall 2016 Lecture 35 Mass Storage Slides based on Text by Silberschatz, Galvin, Gagne Various sources 1 1 Questions For You Local/Global
More informationLATEST INTEL TECHNOLOGIES POWER NEW PERFORMANCE LEVELS ON VMWARE VSAN
LATEST INTEL TECHNOLOGIES POWER NEW PERFORMANCE LEVELS ON VMWARE VSAN Russ Fellows Enabling you to make the best technology decisions November 2017 EXECUTIVE OVERVIEW* The new Intel Xeon Scalable platform
More informationNEC Express5800 A2040b 22TB Data Warehouse Fast Track. Reference Architecture with SW mirrored HGST FlashMAX III
NEC Express5800 A2040b 22TB Data Warehouse Fast Track Reference Architecture with SW mirrored HGST FlashMAX III Based on Microsoft SQL Server 2014 Data Warehouse Fast Track (DWFT) Reference Architecture
More informationHardware & System Requirements
Safend Data Protection Suite Hardware & System Requirements System Requirements Hardware & Software Minimum Requirements: Safend Data Protection Agent Requirements Console Safend Data Access Utility Operating
More informationPerformance Modeling and Analysis of Flash based Storage Devices
Performance Modeling and Analysis of Flash based Storage Devices H. Howie Huang, Shan Li George Washington University Alex Szalay, Andreas Terzis Johns Hopkins University MSST 11 May 26, 2011 NAND Flash
More informationAccelerating Spectrum Scale with a Intelligent IO Manager
Accelerating Spectrum Scale with a Intelligent IO Manager Ray Coetzee Pre-Sales Architect Seagate Systems Group, HPC 2017 Seagate, Inc. All Rights Reserved. 1 ClusterStor: Lustre, Spectrum Scale and Object
More informationJANUARY 28, 2014, SAN JOSE, CA. Microsoft Lead Partner Architect OS Vendors: What NVM Means to Them
JANUARY 28, 2014, SAN JOSE, CA PRESENTATION James TITLE Pinkerton GOES HERE Microsoft Lead Partner Architect OS Vendors: What NVM Means to Them Why should NVM be Interesting to OS Vendors? New levels of
More informationCloud Monitoring as a Service. Built On Machine Learning
Cloud Monitoring as a Service Built On Machine Learning Table of Contents 1 2 3 4 5 6 7 8 9 10 Why Machine Learning Who Cares Four Dimensions to Cloud Monitoring Data Aggregation Anomaly Detection Algorithms
More informationEMC Disk Tiering Technology Review
EMC Disk Tiering Technology Review Tony Negro EMC Corporation Wednesday, February 06, 2013 12:15 PM Session Number 13154 Agenda Basis for FAST Implementation Characteristics Operational Considerations
More informationIBM and HP 6-Gbps SAS RAID Controller Performance
IBM and HP 6-Gbps SAS RAID Controller Performance Evaluation report prepared under contract with IBM Corporation Introduction With increasing demands on storage in popular application servers, the server
More informationHigh Performance File Serving with SMB3 and RDMA via SMB Direct
High Performance File Serving with SMB3 and RDMA via SMB Direct Tom Talpey, Microsoft Greg Kramer, Microsoft Protocol SMB Direct New protocol supporting SMB 3.0 over RDMA Minimal CPU overhead High bandwidth,
More informationEMC Unified Storage for Oracle Database 11g/10g Virtualized Solution. Enabled by EMC Celerra and Linux using FCP and NFS. Reference Architecture
EMC Unified Storage for Oracle Database 11g/10g Virtualized Solution Enabled by EMC Celerra and Linux using FCP and NFS Reference Architecture Copyright 2009 EMC Corporation. All rights reserved. Published
More informationSMB Direct Update. Tom Talpey and Greg Kramer Microsoft Storage Developer Conference. Microsoft Corporation. All Rights Reserved.
SMB Direct Update Tom Talpey and Greg Kramer Microsoft 1 Outline Part I Ecosystem status and updates SMB 3.02 status SMB Direct applications RDMA protocols and networks Part II SMB Direct details Protocol
More informationWorkload Optimized Systems: The Wheel of Reincarnation. Michael Sporer, Netezza Appliance Hardware Architect 21 April 2013
Workload Optimized Systems: The Wheel of Reincarnation Michael Sporer, Netezza Appliance Hardware Architect 21 April 2013 Outline Definition Technology Minicomputers Prime Workstations Apollo Graphics
More informationEMC Tiered Storage for Microsoft SQL Server 2008 Enabled by EMC CLARiiON CX4 and Enterprise Flash Drives
EMC Tiered Storage for Microsoft SQL Server 2008 Enabled by EMC CLARiiON CX4 and Enterprise Flash Drives A Detailed Review EMC Information Infrastructure Solutions Abstract This white paper demonstrates
More informationHigh Performance SSD & Benefit for Server Application
High Performance SSD & Benefit for Server Application AUG 12 th, 2008 Tony Park Marketing INDILINX Co., Ltd. 2008-08-20 1 HDD SATA 3Gbps Memory PCI-e 10G Eth 120MB/s 300MB/s 8GB/s 2GB/s 1GB/s SSD SATA
More informationPerformance Implications of Storage I/O Control Enabled NFS Datastores in VMware vsphere 5.0
Performance Implications of Storage I/O Control Enabled NFS Datastores in VMware vsphere 5.0 Performance Study TECHNICAL WHITE PAPER Table of Contents Introduction... 3 Executive Summary... 3 Terminology...
More informationNST6000 UNIFIED HYBRID STORAGE. Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment
DATASHEET TM NST6000 UNIFIED HYBRID STORAGE Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment UNIFIED The Nexsan NST6000 unified hybrid storage system is ideal for organizations
More informationMicrosoft SQL Server in a VMware Environment on Dell PowerEdge R810 Servers and Dell EqualLogic Storage
Microsoft SQL Server in a VMware Environment on Dell PowerEdge R810 Servers and Dell EqualLogic Storage A Dell Technical White Paper Dell Database Engineering Solutions Anthony Fernandez April 2010 THIS
More informationEMC VFCache. Performance. Intelligence. Protection. #VFCache. Copyright 2012 EMC Corporation. All rights reserved.
EMC VFCache Performance. Intelligence. Protection. #VFCache Brian Sorby Director, Business Development EMC Corporation The Performance Gap Xeon E7-4800 CPU Performance Increases 100x Every Decade Pentium
More informationEMC Virtual Infrastructure for Microsoft Exchange 2007 Enabled by EMC CLARiiON CX4-120 and VMware vsphere 4.0 using iscsi
EMC Virtual Infrastructure for Microsoft Exchange 27 Enabled by EMC CLARiiON CX4-12 and Applied Technology Abstract This white paper details a solution built and tested using EMC CLARiiON CX4-12 and VMware
More informationWebinar Series: Triangulate your Storage Architecture with SvSAN Caching. Luke Pruen Technical Services Director
Webinar Series: Triangulate your Storage Architecture with SvSAN Caching Luke Pruen Technical Services Director What can you expect from this webinar? To answer a simple question How can I create the perfect
More informationW H I T E P A P E R. Comparison of Storage Protocol Performance in VMware vsphere 4
W H I T E P A P E R Comparison of Storage Protocol Performance in VMware vsphere 4 Table of Contents Introduction................................................................... 3 Executive Summary............................................................
More informationInfrastructure Tuning
Infrastructure Tuning For SQL Server Performance SQL PASS Performance Virtual Chapter 2014.07.24 About David Klee @kleegeek davidklee.net gplus.to/kleegeek linked.com/a/davidaklee Specialties / Focus Areas
More informationSolace Message Routers and Cisco Ethernet Switches: Unified Infrastructure for Financial Services Middleware
Solace Message Routers and Cisco Ethernet Switches: Unified Infrastructure for Financial Services Middleware What You Will Learn The goal of zero latency in financial services has caused the creation of
More informationOnline Transaction Processing Workloads First Published On: Last Updated On:
Online Transaction Processing Workloads First Published On: 07-20-2016 Last Updated On: 07-20-2016 1 Table of Contents 1. Executive Summary 1.1.Executive Summary 2. Introduction 2.1.Overview 2.2.vSAN 6.2
More informationInfiniBand Networked Flash Storage
InfiniBand Networked Flash Storage Superior Performance, Efficiency and Scalability Motti Beck Director Enterprise Market Development, Mellanox Technologies Flash Memory Summit 2016 Santa Clara, CA 1 17PB
More informationSTORAGE CONSOLIDATION WITH IP STORAGE. David Dale, NetApp
STORAGE CONSOLIDATION WITH IP STORAGE David Dale, NetApp SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies and individuals may use this material in
More informationNutanix Tech Note. Virtualizing Microsoft Applications on Web-Scale Infrastructure
Nutanix Tech Note Virtualizing Microsoft Applications on Web-Scale Infrastructure The increase in virtualization of critical applications has brought significant attention to compute and storage infrastructure.
More informationDemartek Evaluation Accelerated Business Results with Seagate Enterprise Performance HDDs
May 2017 Demartek Evaluation Accelerated Business Results with Seagate Enterprise Performance HDDs Executive Summary In today s world of digital transformation, organizations require high performance compute
More informationWhat is QES 2.1? Agenda. Supported Model. Live demo
What is QES 2.1? Agenda Supported Model Live demo QES-Based Unified Storage Windows Server Block File iscsi CIFS NFS QES 2.1 One Architecture & Three Configurations SSD SSD Spinning Disk Hybrid All Flash
More informationNFS/RDMA over 40Gbps iwarp Wael Noureddine Chelsio Communications
NFS/RDMA over 40Gbps iwarp Wael Noureddine Chelsio Communications Outline RDMA Motivating trends iwarp NFS over RDMA Overview Chelsio T5 support Performance results 2 Adoption Rate of 40GbE Source: Crehan
More informationWHITE PAPER. Optimizing Virtual Platform Disk Performance
WHITE PAPER Optimizing Virtual Platform Disk Performance Optimizing Virtual Platform Disk Performance 1 The intensified demand for IT network efficiency and lower operating costs has been driving the phenomenal
More informationAccelerating Microsoft SQL Server 2016 Performance With Dell EMC PowerEdge R740
Accelerating Microsoft SQL Server 2016 Performance With Dell EMC PowerEdge R740 A performance study of 14 th generation Dell EMC PowerEdge servers for Microsoft SQL Server Dell EMC Engineering September
More informationInterface Trends for the Enterprise I/O Highway
Interface Trends for the Enterprise I/O Highway Mitchell Abbey Product Line Manager Enterprise SSD August 2012 1 Enterprise SSD Market Update One Size Does Not Fit All : Storage solutions will be tiered
More informationIBM InfoSphere Streams v4.0 Performance Best Practices
Henry May IBM InfoSphere Streams v4.0 Performance Best Practices Abstract Streams v4.0 introduces powerful high availability features. Leveraging these requires careful consideration of performance related
More informationNetwork Design Considerations for Grid Computing
Network Design Considerations for Grid Computing Engineering Systems How Bandwidth, Latency, and Packet Size Impact Grid Job Performance by Erik Burrows, Engineering Systems Analyst, Principal, Broadcom
More informationStorage validation at GoDaddy Best practices from the world s #1 web hosting provider
Storage validation at GoDaddy Best practices from the world s #1 web hosting provider Julia Palmer Storage and Backup Manager Justin Richardson Senior Storage Engineer Agenda and Benefits Agenda Faster,
More information