Level Plus. Magnetostrictive Liquid-Level Transmitters with Temposonics Technology
|
|
- Delphia Small
- 6 years ago
- Views:
Transcription
1 Level Plus Magnetostrictive Liquid-Level Transmitters with Temposonics Technology BRIEF OPERATION MANUAL FOR SAFE USE M-Series Model MC420 Analog Transmitter
2
3 UNITED STATES GENERAL: Tel: Fax: MAILING AND SHIPPING ADDRESS: MTS Systems Corporation Sensors Division 3001 Sheldon Drive Cary, North Carolina, 27513, USA CUSTOMER SERVICE: Tel: Fax: TECHNICAL SUPPORT AND APPLICATIONS: 24 Hour Emergency Technical Support Tel: Model MC420 Brief Operation Manual for Safe Use Contact Information OFFICE HOURS (EST): Monday - Thursday: 8:00 a.m. to 5:00 p.m. Friday: 8:00 a.m. to 4:00 p.m. REMITTANCE ADDRESS: MTS Systems Corporation Sensors Division NW 5872 P.O. Box 1450 Minneapolis, MN, TERMS & CONDITIONS: The parties expressly agree that the purchase and use of Material and/ or Services from Division are subject to MTS Terms and Conditions, in effect as of the date of this document, which are located at html and are incorporated by reference into this and any ensuing contract. Printed Terms and Conditions can be provided upon request by ing sensorsinfo@mts.com or if you prefer, go to mtssensors.com/index and click the Terms and Conditions link on the page footer to download the PDF. Contact Information GERMANY GENERAL: Tel.: Fax: info.de@mtssensors.com MAILING AND SHIPPING ADDRESS: MTS Sensor Technologie, GmbH & Co. KG Auf dem Schüffel 9 D Lüdenscheid, Germany TECHNICAL SUPPORT AND APPLICATIONS: Tel.: info.de@mtssensors.com JAPAN GENERAL: Tel.: Fax: info.jp@mtssensors.com MAILING AND SHIPPING ADDRESS: Technology Corporation 737 Aihara-cho, Machida-shi Tokyo , Japan TECHNICAL SUPPORT AND APPLICATIONS: Tel.: Fax: i Brief Operation Manual for Safe Use, Document Number: Revision B (EN) 01/2015
4 Model MC420 Brief Operation Manual for Safe Use Table of Contents Table of Contents Contact information United States... i Germany...i Japan...i Safety Instructions Intended Use...1 Installation, commissioning and operation...1 Special conditions for use in explosion-hazardous areas...1 Model number identification Model number configuration... 2 Marking... 3 Entity parameters... 3 Basic wiring IS Installation...4 Wiring connections... 4 Safety barrier examples... 4 Accessories Floats...5 Agency Information EC declaration of conformity...6 Brief Operation Manual for Safe Use, Document Number: Revision B (EN) 01/2015 ii
5 Model MC420 Brief Operation Manual for Safe Use Safety Instructions Safety instructions The Brief Operation Manual for Safe Use contains safety instructions. For further information do consult the Operation and Installation Manual, document no.: , available on the Level Product CD, part no.: supplied with your level transmitter or cost free download at www. mtssensors.com. INTENDED USE The Level Plus Model MC420 liquid level transmitter is used for continuous measurement of product level, interface level, and/or temperature of liquids in containers in hazardous areas. INSTALLATION, COMMISSIONING AND OPERATION The liquid level transmitter may only be installed, connected, operated and maintained by trained technical personnel. The technical personnel must strictly adhere to the Operating Instructions, prevailing standards, legal regulations and certificates (depending on application). If the Brief Operating Manual for Safe Use does not provide sufficient information, you must read the Operation and Installation Manual. There, you can find detailed information on the device. The operator may only perform direct replacement of like components manufactured by MTS that are explicitly permitted in the Operating Instructions. Do not operate damaged products and secure them against unintentional commissioning. Mark the damaged product as being defective. If faults cannot be rectified, the products must be taken out of service and secured against unintentional commissioning. The product is designed to meet state-of-the-art safety requirements, has been tested and left the factory in a condition in which it is safe to operate. Relevant regulations and European standards have been observed. As the user, you are responsible for complying with the following safety conditions: - Installation instructions - Local prevailing standards and regulations Only use the product according to its specification. Safety Instructions SPECIAL CONDITIONS FOR USE IN EXPLOSION-HAZARDOUS AREAS Model MC420 sensors may only be connected to certified intrinsically safe circuits (Ex ia or Ex ib). The electronics housing is to be installed in zone 1 (category 2G, EPL Gb}. The sensor pipe/hose may be installed in zone 0 (category 1, EPL Ga} if not restricted below. Equipotential bonding shall be installed inside and outside the hazardous area along the cable for supply and data. Float usage: - Metallic floats may only be used if they have a weight offset (asymmetric weight distribution). - Metallic floats on non-metallic pipes may not be used. - Aluminum floats may not be used. Plastic floats may only be installed in hazardous areas which require apparatus of category 1G (for zone 0} with explosion group IIA. Plastic floats may not be used on non-metallic pipes. 1 Brief Operation Manual for Safe Use, Document Number: Revision B (EN) 01/2015
6 Model MC420 Brief Operation Manual for Safe Use Model Number Identification Model number configuration TRANSMITTER MODEL = M C M-Series Model MC420 liquid-level transmitter Comes with one standard product level float (part number X, see Standard float section below). TRANSMITTER ORDER LENGTHS = 6-8 Model Number Identification Length Code Length Code Length Code 457 mm (18 in.) = mm (72 in.) = mm (144 in.) = mm (20 in.) = mm (84 in.) = mm (156 in.) = mm (24 in.) = mm (96 in.) = mm (168 in.) = mm (36 in.) = mm (108 in.) = mm (180 in.) = mm (48 in.) = mm (120 in.) = mm (192 in.) = mm (60 in.) = mm (132 in.) = mm (204 in.) = mm (216 in.) = 216 Standard Range/lengths 457 mm (18 in.) to 5486 mm (216 in.) OPTIONAL ACCESSORIES = 9-10 FM / CSA Approved 00 = Standard float (part no.: ) T0 = Standard float with Stainless-steel tag F0 = Non-Standard float FT = Non-standard float with Stainless-steel tag ATEX Approved 0P = Standard float (part no.: ) with blue cable FP = Non-standard float with blue cable No Approval 0N = Standard float (part no.: ) with gray cable FN = Non-standard float with gray cable Non-standard floats must be ordered separately. Requires a stop collar, part no.: (Which must be ordered separately) APPROVAL AGENCY = 11 F = FM Approval E = ATEX Approval C = CSA Approval N = NEPSI Approval Brief Operation Manual for Safe Use, Document Number: Revision B (EN) 01/2015 2
7 Model MC420 Brief Operation Manual for Safe Use Marking & Entity Parameters Marking Model Option (9, 10) ATEX marking MC OP, FP II 1/2 G Ex ia IIB T4 Ga/Gb Table 1. Approval marking Entity Parameters Entity parameters ATEX Ui = 28 Vdc Ii = 118 ma Ci = Negligibly low Li = 0.2 mh Table 2. MC420 barrier entity parameters Total power consumption Pi Ambient temperature at the electronics 1.3 W -20 to +40 C (electronics) 1.2 W -20 to +60 C (electronics) 1.0 W -20 to +80 C (electronics, functionality up to 71 C) to +125 C (sensing element) to 105 C (temperature sensor) Model Number Identification 3 Brief Operation Manual for Safe Use, Document Number: Revision B (EN) 01/2015
8 Model MC420 Brief Operation Manual for Safe Use Basic Wiring Table 3. Power and ambient temperature ranges IS Installation Non Hazardous Area Hazardous Area Certified Safety Barriers 24 Vdc Supply- Voltage Transmitter Figure 1. Safety barrier connections Wiring connections I (A) 4-20 ma I.S. Ground connection Certified Basic Wiring & Connections Accessories Figure 2. NEMA 4X housing with integrated cable. Safety barrier examples Supplier Type Uo Maximum voltage Io Maximum current Po Maximum power Maximum resistance STAHL 9001/ Vdc 91 mw 637 mw 350Ω 1 Number of channels Table 4. Safety barrier parameters Floats Model MC420 transmitters should be used with a float having an offset weight and made of stainless steel or Hastelloy C. This allows the float to stay in contact with the pipe to prevent the buildup of electrostatic charge. For detailed information about floats, refer to the Accessories Catalog, MTS part number Non-metalic floats with a projected surface area of less than 5,000 mm² should only be used in Zone 0, Gas group IIA such as float part Brief Operation Manual for Safe Use, Document Number: Revision B (EN) 01/2015 4
9 numbers , , , , and All other non-metallic floats offered by MTS such as, , , and , should not be used in a hazardous area application. NITROPHYL FLOATS 18 mm Float and dimension reference (.07 in.) dia. Projected surface area Part number C L Model MC420 Brief Operation Manual for Safe Use Accessories 76 mm (3 in.) Magnet Added weight for interface floats 2356 mm² mm (1.2 in.) dia TEFLON FLOATS Float and dimension reference 9 mm (0.35 in.) 18 mm (0.7 in.) dia. Projected surface area Part number Centerline of Magnet mm (3 in.) Magnet 4635 mm² mm (2.38 in.) dia Accessories 5 Brief Operation Manual for Safe Use, Document Number: Revision B (EN) 01/2015
10 Model MC420 Brief Operation Manual for Safe Use EC Declaration of Conformity EC Declaration of Conformity EG-Konformitätserklärung Déclaration CE de Conformité EC13.002C MTS Systems Corporation - Sensors Division, 3001 Sheldon Drive, Cary, NC, USA declares as manufacturer in sole responsibility that the products erklärt als Hersteller in alleiniger Verantwortung, dass die Produkte déclare en qualité de fabricant sous sa seule responsabilité que les produits Agency Liquid Level Sensor MRA x a xxxxxxxxxxxx with a = F, G, H, J, K, P, R, S, T, U MC420 xxx a b c with a = 0 or F, b = P or 2, c = E (x = not relevant) comply with the regulations of the following European Directives: den Vorschriften folgender Europäischen Richtlinien entsprechen: sont conformes aux prescriptions des directives européennes suivantes : 94/9/EC Equipment and protective systems for use in potentially explosive atmospheres Geräte und Schutzsysteme zur Verwendung in explosionsgefährdeten Bereichen Appareils et systèmes de protection à être utilisés en atmosphères explosibles 2004/108/EC Electromagnetic Compatibility Elektromagnetische Verträglichkeit Compatibilité électromagnétique Applied harmonized standards: Angewandte harmonisierte Normen: Normes harmonisées appliquées : EN :2009, EN :2007, EN :2007 EN :2006, EN :2006 EC type examination certificate: EG-Baumusterprüfbescheinigung: Certificat de l examen CE de type : issued by / ausgestellt durch / exposé par: PTB 10 ATEX 2011 X Physikalisch-Technische Bundesanstalt (PTB) Braunschweig, Germany Notified body for quality assurance control: Physikalisch-Technische Bundesanstalt (PTB) Benannte Stelle für Qualitätsüberwachung: Braunschweig, Germany Organisme notifié pour l assurance qualité : Ident number / Kennnummer / Numéro d identification : 0102 Marking / Kennzeichnung / Marquage : II 1/2G Ex ia IIB T4 Ga/Gb resp. II 2G Ex ia IIB T4 Gb resp. II 1/2G Ex ia IIA T4 Ga/Gb resp. II 2G Ex ia IIA T4 Gb Lüdenscheid, MTS Sensor Technologie GmbH & Co. KG, Auf dem Schüffel 9, Lüdenscheid, Germany Thomas Muckenhaupt Quality Management / ATEX Representative Page 1 of 1 Brief Operation Manual for Safe Use, Document Number: Revision B (EN) 01/2015 6
11
12 Document Part Number: Revision B (EN) 01/2015 MTS, Temposonics and Level Plus are registered trademarks of MTS Systems Corporation. All other trademarks are the property of their respective owners. Printed in USA. Copyright 2015 MTS Systems Corporation. All Rights Reserved in all media. All specifications are subject to change. Contact MTS for specifications and engineering drawings that are critical to your application. Drawings contained in this document are for reference only. Go to for the latest product information. MTS Systems Corporation Sensors Division 3001 Sheldon Drive Cary, North Carolina, 27513, USA Tel.: Fax: info.us@mtssensors.com MTS Sensor Technologie GmbH & Co. KG Auf dem Schüffel 9 D Lüdenscheid, Germany Tel.: Fax: info.de@mtssensors.com Technology Corporation 737 Aihara-cho, Machida-shi Tokyo , Japan Tel.: Fax: info.jp@mtssensors.com
Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology
Level Plus Magnetostrictive Liquid-Level Sensors with Temposonics Technology M-Series Model USTD II Underground Storage Tank Level Sensing for Leak Detection and Inventory Monitoring FEATURES DDA Output
More informationLevel Plus. Magnetostrictive Liquid-Level Transmitters with Temposonics Technology. Liquid-Level Transmitter Accessories Catalog
Level Plus Magnetostrictive Liquid-Level Transmitters with Temposonics Technology Liquid-Level Transmitter Accessories Catalog TABLE OF CONTENTS Accessories Overview...3 Floats Standard Floats...4.Standard
More informationLevel Plus. Product Accessories. Magnetostrictive Liquid-Level Sensors with Temposonics Technology
Level Plus ostrictive Liquid-Level Sensors with Temposonics Technology SENSORS Product Accessories Floats, s, Meters, Enclosures, Indicators, Interface Terminals and Programming Document Part Number 551103
More informationLevel Plus. Product Accessories. Magnetostrictive Liquid-Level Sensors with Temposonics Technology
Level Plus ostrictive Liquid-Level Sensors with Temposonics Technology SENSORS Product Accessories Floats, s, Meters, Enclosures, Indicators, Interface Terminals and Programming Document Part Number 551103
More informationLevel Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. LP-Series Board Replacement Operation Manual
Level Plus Magnetostrictive Liquid Level Transmitters with Temposonics Technology LP-Series Board Replacement 1. Contact information United States General Tel: +1-919-677-0100 Fax: +1-919-677-2343 E-mail:
More informationLevel Plus. Liquid-Level Sensors With Temposonics Technology. Accessories Catalog
Features Level Plus Liquid-Level Sensors With Temposonics Technology Floats, s and Accessories for Process Level and Tank Gauging Applications Accessories Catalog Variety of styles and sizes to fit most
More informationLevel Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. Accessories for liquid level transmitters Catalog
Level Plus Magnetostrictive Liquid Level Transmitters with Temposonics Technology Accessories for liquid level transmitters Table of contents 1. Floats... 3 1.1 Standard floats... 3 1.2 Low-liftoff float...
More informationLevel Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. Accessories Catalog
Level Plus ostrictive Liquid-Level Sensors with Temposonics Technology Accessories Catalog SENSORS Document 551103 Revision C Floats, s, Meters, Enclosures, Indicators, Interface Terminals and Programming
More informationTemposonics. Magnetostrictive, Linear-Position Sensors. G-Series Embedded Redundant Model GTE Analog (Voltage/Current) Data Sheet
Temposonics Magnetostrictive, Linear-Position Sensors G-Series Embedded Redundant Model GTE Analog (Voltage/Current) Data Sheet Document Part Number 551386 Revision C (EN) 05/2016 Model GTE embedded redundant
More informationTemposonics Magnetostrictive Linear Position Sensors
Temposonics Magnetostrictive Linear Position Sensors TempoLink Smart Assistant I AM V THE NEW GENERATION Table of contents 1. Introduction...3 2. Safety instructions...4 2.1 Intended use...4 2.2 Foreseeable
More informationTemposonics. Magnetostrictive Linear Position Sensors. PROGRAMMING & CONFIGURATION GBS Analog via Bluetooth. The Measurable Difference
Temposonics Magnetostrictive Linear Position Sensors PROGRAMMING & CONFIGURATION GBS Analog via Bluetooth The Measurable Difference Programming & Configuration These instructions describe the installation
More informationMagnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR3/4 MLG Transmitter with Analog Output.
Magnetostrictive Liquid-Level Sensors with Temposonics Technology Revision RA010615 M-Series Model MR3/4 MLG Transmitter with Analog Output Data Sheet FEATURES 4 to 20 ma Analog Output with HART No Scheduled
More informationTemposonics. Magnetostrictive Linear Position Sensors. EE Analog Data Sheet
Temposonics Magnetostrictive Linear Position Sensors EE Analog Pressure-resistant sensor rod Compact sensor housing High operating temperature MEASURING TECHNOLOGY For position measurement, the absolute,
More informationTemposonics. Magnetostrictive Linear Position Sensors. ET SSI ATEX / IECEx / CEC / NEC Certified Operation Manual
Temposonics Magnetostrictive Linear Position Sensors ET SSI ATEX / IECEx / CEC / NEC Certified Table of contents 1. Introduction...3 1.1 Purpose and use of this manual...3 1.2 Used symbols and warnings...3
More informationTemposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. C-Series Core Sensor, Models CS and CM Analog Outputs (Voltage/Current)
Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors C-Series Core Sensor, Models CS and CM Analog Outputs (Voltage/Current) SENSORS Document Part Number 551020 Revision K Product
More informationM E M O R A N D U M I.S.
Physikalisch-Technische Bundesanstalt Department 3.6 " Intrinsic safety and Safety of Systems" 38023 Braunschweig Germany P.O. Box 33 45 Tel. ++49 531 592-3630 Fax ++49 531 592-3605 M E M O R A N D U M
More informationOperating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015
Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in
More informationCerabar S PMC71, PMP71, PMP ma HART, PROFIBUS PA, FOUNDATION Fieldbus
Safety Instructions PMC71, PMP71, PMP75 4-20 ma HART, PROFIBUS PA, FOUNDATION Fieldbus Ex ia IIC T6 Ga/Gb IECEx KEM06.0011 0 XA00696P-D Safety instructions for electrical apparatus for explosion-hazardous
More informationPTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions
Device with II 2G EX i approval Geräte mit II 2G EX i Zulassung Appareils avec mode de protection II 2G EX i Example / Beispiel / Exemple Type 6106 Operating Instructions Bedienungsanleitung Manuel d utilisation
More informationTemposonics. R-Series POWERLINK. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm
Temposonics Absolute, Non-Contact Position Sensors R-Series Temposonics RP and RH Measuring length 25-7600 mm For short cycle times Real Time Measurement Rugged Industrial Sensor Linear and Absolute Measurement
More informationLevel Plus. Liquid-Level Product Catalog. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. Document Part Number Revision E
Level Plus Magnetostrictive Liquid-Level Sensors with Temposonics Technology SENSORS Document Part Number 551050 Revision E Liquid-Level Product Catalog Contact Information United States General: Tel:
More information(1) EC-TYPE-EXAMINATION CERTIFICATE (Translation) (2) Equipment and protective systems intended for use in potentially explosive atmospheres Directive 94/9/EC (3) EC-type-examination Certificate number
More informationSafety instructions. IECEx TUN Ex ia IIC T6 Gb
Safety instructions ÜSB62-36G.C_* and ÜSB62-30W.C_* IECEx TUN 07.0002 Ex [ia Ga] IIC T6 Gb Ex ia IIC T6 Gb 0044 39878 Content 1 Area of applicability 3 2 General 3 3 Electrical data 3 3.1 Application conditions
More informationMTS Sensors. NEWS 2013 / 2014 Agritechnica 2013 / Hall 1, Booth E127. Position and Angle Measurement in Mobile Machines. The Measurable Difference
Position and Angle Measurement in Mobile Machines NEWS 2013 / 2014 Agritechnica 2013 / Hall 1, Booth E127 The Measurable Difference MAGNETOSTRICTIVE LINEAR SENSORS The magnetostrictive Temposonics MH series
More informationADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.
EN ADAMCZEWSKI Elektronische Messtechnik GmbH Felix-Wankel-Str. 13 / 74374 Zaberfeld Tel. +49 (0)7046-875 Fax +49 (0)7046-7678 vertrieb@ad-messtechnik.de Operating Instructions Supply Isolation Amplifier
More informationLevel Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. Safety Manual LP Series. Safety Integrity Level IEC 61508
Level Plus Magnetostrictive Liquid Level Transmitters with Temposonics Technology Safety Manual Safety Integrity Level IEC 61508 Table of contents 1. Contact information...3 2. Introduction...3 3. Function...4
More informationSMARTLINE RM76 Supplementary instructions
SMARTLINE RM76 Supplementary instructions 2-wire / Guided Radar (TDR) Level Meter Supplementary Instructions for ATEX applications CONTENTS SMARTLINE RM76 1 General safety information 5 1.1 Scope of the
More informationPI-EX-ME-2NAM/COC-24VDC
Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC
More informationInductive sensor with analog output BI15-M30-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass Analog+ Extended operating range 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection
More informationPHOENIX CONTACT - 12/2007
Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel
More informationFieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)
Data Sheet FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex) Intrinsically safe power supply of up to 31 stations on the bus cascadable multi barrier Intrinsically safe connection of up to 4 field
More informationAssembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail
Switch Amplifier Features Assembly -channel isolated barrier 4 V DC supply (Power Rail) Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL
More informationSmart Wireless THUM Adapter
Quick Installation Guide Smart Wireless THUM Adapter Smart Wireless THUM Adapter Start Wireless Considerations Step 1: Physical Installation Step 2: Verify Operation Reference Information Product Certifications
More informationOperating Instructions
Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on
More informationInstallation & Operation Manual
Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas
More informationDR7100 SERIES Supplementary instructions
DR700 SERIES Supplementary instructions Guided Radar (TDR) Level Instrument for 2-wire control systems Supplementary Instructions for ATEX applications AMETEK Drexelbrook - EDO -0-2, DR700-LM ATEX, Issue
More informationRosemount 248 Wireless Temperature Transmitter
Quick Installation Guide Rosemount 248 Wireless Rosemount 248 Wireless Temperature Transmitter Start Wireless Considerations Step 1: Physical Installation Step 2: Verify Operation Reference Information
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection
NCN-FK-N-V-V 002 Model Number NCN-FK-N-V-V Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99
More informationPI-EX-ME-2NAM/COC-120VAC
PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:2 Status: Current Certificate history:
More informationData Sheet. Model ER position sensor, features a versatile rod-and-cylinder design with optional dual rod ends. Interrogation Return wire.
Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors E-Series Model ER Analog / Digital-Pulse (Start/Stop) Output SENSORS Document Part Number 550996 Revision D Data Sheet Model
More informationIECEx Certificate of Conformity
--- Certificate : ECEx PTB 13.0036X Seite 1 von 5 ECEx Certificate ------ -- l "-- - --- --- NTERNATONAL ELECTROTECHNCAL COMMSSON EC Certification Scheme for Explosive Atmospheres for rules and details
More informationLoop-powered Transmitter for Thermocouple Type K (NiCr-Ni)
Data sheet 302040_en MTP300i-SIL-K Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni) Properties 2-wire temperature transmitter for DIN rails Galvanic isolated TC-input with cold-junction compensation
More informationT E M P O S O N I C S I I I INSTALLATION CAUTION! B. CONNECTORS RG Connector. D6 Connector: INTEGRAL CABLE P Integral Cable
T E M P O S O N I C S I I I INSTALLATION C A N B U S O U T P U T 550573 B W I R I N G - C A N b u s O U T P U T S CONNECTORS RG Connector Pin No. Wire Color Function 1 Gray CAN-L 2 Pink CAN-H 3 Yellow
More informationTemposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. E-Series Models EP and EL Analog and Start/Stop Outputs.
Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors E-Series Models EP and EL Analog and Start/Stop Outputs SENSORS Document Part Number: 551248 Revision A Data Sheet Model EP position
More informationMagnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom.
More informationTURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet
Process Automation IS Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to solve the problems associated with the
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters For operation in up to Zone 0 / 20 Features Measures humidity and temperature, outputs also dew point, mixing ratio, absolute humidity
More informationSafety Instructions Cerabar M PMC51, PMP51, PMP55
XA00470P-B/00/EN/14.13 71224652 Products Solutions Services Safety Instructions PMC51, PMP51, PMP55 4-20 ma HART, PROFIBUS PA, FOUNDATION Fieldbus Ex ia IIC T6...T4 Ga/Gb Ex ia IIC T6...T3 Ga/Gb IECEx
More informationPTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions
, Equipment protection fuse with Ex mb II C Gb approval Geräteschutzsicherung mit Zulassung Ex mb II C Gb Fusible de protection d appareil avec homologation Ex mb II C Gb Example / Beispiel / Exemple:
More informationInstallation & Operation Manual
Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas
More informationLevel Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. HART Interface Manual LP Series
Level Plus Magnetostrictive Liquid Level Transmitters with Temposonics Technology HART Interface Manual Table of contents 1. Contact Information...3 2. Terms and Definitions...4 3. Introduction...6 4.
More informationStartup instructions. AutoConfiguration Adapter ACA21-USB (EEC) ACA22-USB (EEC) ACA21-M12 (EEC) ACA22-M12 (EEC)
Startup instructions AutoConfiguration Adapter ACA21-USB (EEC) ACA22-USB (EEC) ACA21-M12 (EEC) ACA22-M12 (EEC) Release 02 04/2014 Technical Support https://hirschmann-support.belden.eu.com The naming of
More informationZener Barriers Bulletin 937Z
Technical Data Zener Barriers Bulletin 937Z Topic Page Introduction 2 Mounting 2 Housing 3 Operating Principle 3 Specifications 6 Introduction Allen-Bradley Zener barriers are a cost-effective solution
More informationPTB 01 ATEX Operating Instructions. Solenoid coil Type AC21 Magnetspule Typ AC21 Bobine magnetique AC21
Solenoid coil Type AC21 Magnetspule Typ AC21 Bobine magnetique AC21 Device with II 2G EX i approval Geräte mit II 2G EX i Zulassung Appareils avec mode de protection II 2G EX i Operating Instructions Bedienungsanleitung
More informationSafety Instructions Levelflex FMP50/51/52/53/54/55/56/57
XA00531F-D/00/EN/16.16 71313127 Products Solutions Services Safety Instructions FMP50/51/52/53/54/55/56/57 4-20 ma HART Control Drawing IS Document: XA00531F-D Safety instructions for electrical apparatus
More informationT E M P O S O N I C S I I I INSTALLATION
T E M P O S O N I C S I I I INSTALLATION A N A L O G O U T P U T W I R I N G - A N A L O G O U T P U T S 550572 B CONNECTORS RG Connector: Pin No. Wire Color Function 1 Gray Output #1 (Displacement) *
More informationSafety instructions Overvoltage protection B81-35
Safety instructions Overvoltage protection B81-35 IECEx BVS 15.0084X Intrinsic safety Document ID: 51001 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 5 4 Application
More informationUFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design
UFD 5 Technical Datasheet Display for ALTOSONIC 5 Configurable display for ALTOSONIC 5 Easy installation Durable design KROHNE 04/2015-0.00000.00.00 CONTENTS UFD 5 1 Product features 3 1.1 Local display
More informationGeneral Specifications
General Specifications Field Wireless Communication Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Communication Module. This product is based on the industrial
More informationDigital Output Module 8-Channel Version for Zone 1 Series 9475/
www.stahl.de > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >
More informationOperating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505
Operating Instructions Intrinsically Safe Isolation Relay for Switches Model: REL-6003 manual_rel-6_0505 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating
More informationManual. Expert Bypass Switch Gude Analog- und Digitalsysteme GmbH Manual Ver
Manual 2016 Gude Analog- und Digitalsysteme GmbH Manual Ver. 1.0.1 Table of contents 1. Device Description 4 1.1 Security Advice... 5 1.2 Content of Delivery... 5 1.3 Description... 5 1.4 Installation...
More informationOperating Instructions for Level Switch for Liquids. Model: RFS
Operating Instructions for Level Switch for Liquids Model: RFS 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Use in Hazardous
More informationSignal processor MS96 for flow sensors MS96-11EX0-R/230VAC
MS96-11EX0-R/230VAC ATEX category II (1) G, Ex Zone 0 ATEX category II (1) D, Ex Zone 20 single-channel signal processor MS96 for connection of an intrinsically safe flow control sensor in zone 0 adjustment
More informationAPPLICATION GUIDE. Interface Modules IM Series.
Interface Modules IM Series APPLICATION GUIDE www.turck.com Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to
More informationTechnical Information Promonitor NRF560
TI00462G/08/EN/03.14 71264171 Products Solutions Services Technical Information For tank side monitor and control of Proservo NMS5 intelligent tank gauge Application is a monitoring unit for use with Proservo
More informationSafety instructions VEGATOR 121, 122
Safety instructions Intrinsic safety IECEx TUN 14.0005X Document ID: 47471 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 3 4 Installation... 4 Supplementary documentation:
More informationProcess display RIA 251. Digital loop powered display for ma current loops. Application areas. Plant and machine construction.
Technical information TI 063R/09/en Mat. No. 510 00857 Process display RIA 251 Digital loop powered display for 4...20 ma current loops Application areas Plant and machine construction Control panels Laboratory
More informationTemposonics. User s Manual. MH-CAN Testkit. CANopen & SAE J1939. Absolute, Non-Contact Position Sensors. Document Part Number.
Temposonics Absolute, Non-Contact Position Sensors MH-CAN Testkit Document Part Number 551292 Revision A CANopen & SAE J1939 Kit includes the CAN Test Interface software with a user friendly Graphical
More informationSafety Instructions Omnigrad TRxx, TCxx, TxCxxx
XA01459T/09/EN/01.16 71340269 Products Solutions Services Safety Instructions Omnigrad TRxx, TCxx, TxCxxx RTD/TC modular thermometers 0ExiaIICT6...T1 X Document: XA01459T Safety instructions for electrical
More informationDigital Output Module 8-Channel Version for Zone 2 Series 9475/
> 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in
More informationDigital Output Module 8-Channel Version for Zone 2 Series 9475/
> 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in
More informationLevel-Lance Model 5400A
Sales Manual Section 100 PRODUCT SPECIFICATION 5400A GENERAL DESCRIPTION The ROBERTSHAW Level-Lance Model 5400A is a microprocessor based, multi-point On-Off capacitance type level detection system. Utilizing
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationSingle/Dual-Port ISDN BRI VoIP Terminal Adapter
SN-DTA Single/Dual-Port ISDN BRI VoIP Terminal Adapter Quick Start Guide Important This is a Class B device and is intended for use in a light industrial or residential environment. It is not intended
More informationMODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)
Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source
More informationTemposonics Magnetostrictive Linear Position Sensors. Temposonics MH-Series Brief Instructions
Temposonics ostrictive Linear Position Sensors Temposonics MH-Series Table of contents 1. Introduction 1. Introduction...2 1.1 Purpose and use of this manual...2 1.2 Used symbols and warnings...2 2. Safety
More informationMagnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationRefer to attachment for more details. Andreas Meyer
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationMANUAL Surge Protectors
PROCESS AUTOMATION MANUAL Surge Protectors DP-LBF-I1.36.DE and DP-LBF- I1.36.IE With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery
More informationUncertified Translation Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (1) EC Type Examination Certificate (2) Equipment and Protective Systems Intended for Use in Potentially Explosive
More informationMODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)
Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source
More informationBLISS ANAND. BA-Series Magnetostrictive Level Transmitter
BLISS ANAND BA-Series Magnetostrictive Level Transmitter BA-Series Magnetostrictive Level Transmitter Index: Product Overview 02 Product Specifications 03 Agency Approvals 04 Product Dimensions And Mounting
More informationDigital Output Module 4-Channel Version for Zone 1 Series 9475/
www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ib > Suitable for Ex i hydraulic valves and solenoid valves > Additional Ex i control input for (in accordance with IEC 61508 through
More informationPROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32
PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32 With regard to the supply of products, the current issue of the following document is applicable: The General Terms
More informationManual Mouse Module CHALLENGER Mi-PS2 / Mi-PS2-B
Manual Mouse Module CHALLENGER Mi-PS2 / Mi-PS2-B GECMA.COMPONENTS GMBH WWW.GECMA.COM TEL. +49 2237 6996-0 FAX -99 MANUAL MI_PS2_B REV 1.3 EN.DOC 31.01.07 A. J. 1 List of contents List of contents... 2
More informationOverfill Prevention Controller EUS-2
H. Timm Elektronik GmbH Humboldtstr. 29 + D - 21509 Glinde Tel. +49 40 248 35 63-0 + Fax +49 40 248 35 63-39 info@timm-elektronik.de + www-timm-elektronik.de Technical Description Overfill Prevention Controller
More informationData Sheet. Model EP position sensor - Full Size Profile Housing Stroke Length: 50 mm to 2500 mm (or 2 in. to 100 in.)
Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors E-Series Models EP and EL Synchronous Serial Interface (SSI) Output Data Sheet Document Part Number: 551299 Revision B Model
More informationOperating Manual Touchpad CHALLENGER TPi
Operating Manual Touchpad CHALLENGER TPi GECMA COMPONENTS GMBH WWW.GECMA.COM TEL. +49 2237 6996-0 FAX. +99 MANUAL TPI REV 1.4 EN.DOC 31.01.07 A.J. 1 List of Contents List of Contents... 2 Introduction...
More information4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F
4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i solenoid valves, piezo and booster-valves Intrinsically safe Ex ia IIC outputs Additional input for Plant-STOP available (acc. to
More informationINSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F
PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4
More informationSeries 3730 Electropneumatic Positioner Type
Series 3730 Electropneumatic Positioner Type 3730-0 Application Single-acting or double-acting positioner for attachment to pneumatic control valves Reference variable Travels 4 to 20 ma 5.3 to 200 mm
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration
More informationFLEX Ex Spring Clamp Terminal Base
Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification
More informationInductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position
More informationNAMUR INDUCTIVE SENSOR ATEX/IECEx
INDUCTIVE SENSORS NAMUR INDUCTIVE SENSOR ATEX/IECEx CYLINDRICAL HOUSING 6, Dia. M8MM4MM WIRES D.C. VERSION N CONFORMING: Directive ATEX 94/9/CE Group II Category Gas G (Zone 0) and Dust D (Zone ) (Reference
More information4 â Active barrier RN221N with optional HART diagnosis. Technical Information
Technical Information Active barrier with optional HART diagnosis Active barrier with power supply for safe separation of 4 to 20 ma current circuits Application Galvanic isolation of 4 to 20 ma current
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration
More informationDigital Output Module 4-Channel Version for Zone 1 Series 9475/
www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >
More information