Storage Module System
|
|
- Erica Strickland
- 5 years ago
- Views:
Transcription
1 Storage Module System Instruction Manual Publication No LI-COR, inc Superior Street P.O. Box 4425 Lincoln, Nebraska USA Telephone: (402) FAX: Toll-free (U.S. & Canada) Copyright 1991
2 LI-COR Software Product License Agreement and Limited Warranty License Agreement Customer may not reverse assemble or decompile this software. Customer may make copies of the software for archival purposes, or to facilitate its use with the mass storage media of a particular computer (e.g. copy to hard disk). Customer may make copies of the software for use on two or more computers ONLY in the case when the data to be analyzed or manipulated is generated by the same individual LI-COR instrument. Customer has no other rights to copy this software without express permission from LI-COR. Limited Warranty Software: LI-COR warrants for a period of 90 days from the date of purchase that the product will execute its instructions when properly installed on the computer indicated in its instruction manual. LI-COR does not warrant that the software is free from errors. In the event that this product fails to execute properly during its warranty period, customer should contact LI-COR. If the problem cannot be resolved in a reasonable amount of time, the customer's recourse is to return the software and all copies to LI-COR for a refund. Media: LI-COR warrants the media upon which this software is recorded to be free from defects of material or workmanship under normal usage for a period of 90 days from the date of purchase. Should the media prove to be defective in the warranty period, the customer's recourse is to return the media to LI-COR for replacement.
3 General Information CONTENTS PAGE General Information... 3 Sending Data to the Storage Module... 4 Cables... 4 File Configuration... 4 Sending Data to the Computer... 5 Connecting the SC532 Peripheral Device... 5 SMCOM.EXE... 6 General Information... 6 Program Files... 6 Installation... 6 Options... 8 R1600.EXE Specifications and Maintenance Warranty The Storage Module System is a solid state, battery-backed RAM data storage unit used to store data sent from the LI-1600 Steady State Porometer, which can then be sent to a computer for storage and/or data manipulation. The provides 192K bytes of memory in a sealed, stainless steel canister that can be used in field conditions. Data stored in the are sent to a computer or terminal using the SC532 peripheral device. The SC532 requires a 12 VDC input, provided by the AC adapter included ( or VAC). Software (SMCOM) is also included which will enable you to collect and store data from the Storage Module. SMCOM runs on any IBM PC,XT,AT,PS/2 or true IBM compatible computer. This manual describes the procedure for transferring data from the LI-1600 to the Storage Module, and for sending data to your computer or terminal with the SC532 peripheral device and the SMCOM software. General Information 3
4 Sending Data to the CABLES The Storage Module System is connected to the LI-1600 Steady State Porometer using the cable provided. This is the round cable terminated with 9-pin male and female connectors. Use only this cable, as it is specially configured to provide the with 5 VDC power. Power is drawn from the LI-1600 when sending data, or from the AC adapter when using the SC532 to send data to the computer. FILE CONFIGURATION Data are sent to the Storage Module each time the HOLD switch on the LI-1600 is toggled to the left. All data are loaded into a single file until power to the is interrupted. This is done by turning the LI-1600 off. If the LI-1600 is powered off, the time stamp (number of seconds since the LI-1600 was turned on) will be reset. If you wish to reformat the resulting files using the R1600.EXE program to add a date/time stamp, each file will need to be reformatted individually. See the R1600.EXE description for more details. The memory is configured as ring style memory, meaning that new data continue to be stored even after the memory is full. New data are written over the oldest data in the memory. If you do not wish to overwrite data, you should be aware of how much memory has been filled. Each data set from the LI-1600 occupies approximately 124 bytes of storage, meaning that about 1548 sets of data from the LI-1600 can be sent to the storage module before it is completely full. Data in one or several stored files can be sent to a computer using the SC532 peripheral device. 4 Sending Data to the
5 Sending Data to the Computer CONNECTING THE SC532 Follow these steps to send data from the Storage Module System to the computer using the SC532 Peripheral device and the SMCOM software program: Connect the SC532 to the using the 9-pin ribbon cable (SC12) provided. Connect the other end of this cable to the SC532 9-pin RS-232C port labeled "PERIPHERAL". Connect the SC532 to the serial port of your computer using the 25-pin RS-232C ribbon cable provided. If your computer has an AT-type 9-pin serial port, a 9-pin to 25-pin straight-through adapter cable will be required. Plug the AC adapter of the SC532 into an AC power source ( or VAC) after selecting the proper voltage on the adapter. When you have connected the cables as shown below, you are ready to begin sending data to the computer, using the SMCOM program. Serial Port of IBM PC, XT, AT, PS/2 or Compatible 25-pin RS-232C Cable SC532 Peripheral Device SC12 9-pin Ribbon Cable Storage Module AC Adapter Sending Data to the Computer 5
6 SMCOM.EXE GENERAL INFORMATION The SMCOM program is a general purpose communications program for sending data from the Storage Module to your computer or terminal. The SMCOM program contains a variety of options for sending data from data loggers and other instruments; many of these options are not used for capturing data from the LI See the SMCOM Instruction Manual from Campbell Scientific, Inc. for a detailed description of these options. The instructions which follow detail only the information necessary to send data from the LI-1600 to your computer. The files on the disk are: PROGRAM FILES SMCOM - General purpose communications program for the LI-1600 Steady State Porometer. R1600.EXE - Reformats LI-1600 data files (2-line format) into channel groupings. *.HLP - Help file for R1600.EXE. INSTALLATION No special installation procedures are needed to install the SMCOM program. Make a backup copy of the diskette if you plan to use the SMCOM program directly from the floppy disk, or copy the contents of the diskette onto your computer's hard disk. 1) To run the program, type SMCOM <enter> at the DOS prompt. The program will prompt 6 SMCOM.EXE
7 Options SMCOM Ver. X.X Copyright 1986, 1987, 1989, 1990 Campbell Scientific, Inc. Logan, Utah Serial Port Options: 1 - COM1 2 - COM2 3 - COM3 4 - COM4 Option: 2) Enter the appropriate number for the serial port which is connected to the SC532 (usually COM1 or COM2). The following prompt appears: Is the SM232 or SM232A interface being used? (Y/N): 3) Press N, and the SMCOM program will attempt to establish communications with the Storage Module. The baud rate at which the sends and receives data is preset at the factory to 300 baud. The SMCOM program will initially attempt to communicate at higher baud rates. The error message SM192/SM716 Storage Module does not respond! Reducing baud rate... will appear several times, until communications are established at 300 baud. If proper communication is not established, check to be sure that all cables are properly connected, and that the correct serial port was specified. SMCOM.EXE 7
8 Options OPTIONS The SMCOM Options Menu will appear, and is displayed as follows: SMCOM Options: T - Terminal emulator. * A - Collect all data files. * U - Collect uncollected data files. * N - Collect newest data file. L - Collect one data file starting at display pointer L. P - Collect program files. D - Store a.dld program file. F - Store a file. * E - Erase and Reset Storage Module. * S - Switch Settings. * Q - Quit. * These options are valid for use with the Storage Module A - Collect all data files This option copies all data files in the Storage Module to the computer. The SMCOM program will ask you for the root name of the file or files to which you wish to send data. Enter a root name (4 characters or less) and press <enter>. The SMCOM program will detect the file separators (created by interrupting power to the module when sending LI-1600 data) and will assign sequential numbers and.dat extensions to each file sent, starting with the oldest file first. For example, by typing the root filename "DEMO", files will be stored as DEMO 1.dat, DEMO 2.dat, etc. A data collection format menu appears as follows: F - Final Storage (FS) Format D - FS converted to ASCII arrays with IDs C - FS converted to comma delineated ASCII arrays A - As stored (8 bit data) * P - As stored (strip parity) 8 SMCOM.EXE
9 Options Select P to send LI-1600 data to the computer. This option sets the parity bit (bit 8) of each byte to zero when it is stored in a file. The message "xxxxxx: Writing to file ROOTn.dat." will appear, where "xxxxxx" is the beginning location number of the file in the , and ROOT is the file name you entered. The data can now be viewed or manipulated as you choose. U - Collect uncollected data files This option functions the same as the A option above, with the exception that only the files created since the last time the U or A option was executed are collected (assuming that the has not been reset using the Erase option. See below). N - Collect newest data file This option collects the most recently stored file. E - Erase and Reset Storage Module This function erases all files in the , and resets the storage module to the default positions. NOTE: This function resets the baud rate in the to 76800/9600. The LI-1600 will not communicate with the Storage Module at this baud rate. Before attempting to read data into the Storage Module again, you must reset the baud rate to 300 with the S option (see below). S - Switch Settings Press S to reset the baud rate in the The cursor will move to the top of the screen. Use the up and down arrow keys or the <enter> key to scroll through the options. Use the spacebar to highlight 300 baud, and press <esc>. The program returns to the Main Menu after resetting the baud rate. Q - Quit Quits SMCOM and returns to DOS. SMCOM.EXE 9
10 R1600.EXE GENERAL INFORMATION R1600.EXE will reformat an LI-1600 data file that was output using the 2-line format which the instrument produces. The R1600 program will also add an offset time stamp to any LI-1600 data file, if desired, which will be added to the #S (time since instrument turn on, in seconds) values to produce a real time identifier. R1600 creates a file that has all the channels listed horizontally, and sorted by time vertically. For example: SOURCE FILE... #C1000E+1 #S2991E+1 DR3500E-3 CD4667E-2 TR5234E-1 QU6234E+0 HM7234E+1 LT8234E+2 CT9234E+3 FL1034E+4 PR1162E+2 AP1200E+0 DEST. FILE... #C #S DR CD TR QU... 00:00: :00: :01: To run the R1600 program, log onto the proper drive and at the DOS prompt type R1600 <source file> <destination> where <source> is the appropriate file specifier, and <destination> is the print destination [optional; the default destination is CON (console)]. To add an offset time to the source file, type R1600 <source> <destination> <hh:mm:ss> For example, typing "R1600 corn.dat corn.prn 14:30:00" at the DOS prompt would reformat the source file corn.dat, send it to the printer, and add a time offset of fourteen 10 R1600.EXE
11 General Information hours and 30 minutes to the time since instrument turn-on, which would be added to the #S value in the resulting data file. If you type R1600 <enter>. with no source file listed, a help file showing the proper command format for beginning the R1600 program will automatically be printed. R1600.EXE 11
12 Specifications and Maintenance BACKUP POWER Memory backup power for the Storage Module is provided by an internal 3.5 VDC lithium chloride battery, when the module is disconnected from a primary power source. Approximately 10 years of RAM backup power can be expected at room temperature. Higher temperatures increase the current consumption of the RAM chips and the self-discharge rate of the battery, while lower temperatures decrease the battery's capacity. At 50 C, battery life will be approximately 3 years; at -25 C battery life will be about 6 years. If possible, maintain the Storage Module at or near room temperature when not connected to a primary power source. SPECIFICATIONS Power Requirements: 5 VDC ± 0.4 V at 100 ma maximum (provided by the LI-1600). Power Consumption: Active Processing: 18 ma (average). Active, but not busy: 3 ma (average). Low Power Standby State: 250 µa (average). Memory Backup Battery: 3.5 VDC Lithium Thionyl Chloride. Expected Battery Life: 25 C 10 years 50 C 3 years -25 C 6 years Storage Capacity: 192,896 bytes. Dimensions: " ( cm). Canister: Sealed stainless steel. Processor: Hitachi Operating Temperature: -35 C to +65 C Baud Rates: 300, 1200, 9600, 76800, 76800/9600. Memory Configuration: Ring style (default) or fill and stop (user selectable). 12 Specifications and Maintenance
13 General Information MAINTENANCE There are no user serviceable parts in the Storage Module. If the battery requires replacement (SM192 no longer stores or retains data), the Storage Module must be returned to LI-COR. Specifications and Maintenance 13
14 WARRANTY Each LI-COR, inc. instrument is warranted by LI-COR, inc. to be free from defects in material and workmanship; however, LI-COR, inc.'s sole obligation under this warranty shall be to repair or replace any part of the instrument which LI-COR, inc.'s examination discloses to have been defective in material or workmanship without charge and only under the following conditions, which are: 1. The defects are called to the attention of LI-COR, inc. in Lincoln, Nebraska, in writing within one year after the shipping date of the instrument. 2. The instrument has not been maintained, repaired, or altered by anyone who was not approved by LI-COR, inc. 3. The instrument was used in the normal, proper, and ordinary manner and has not been abused, altered, misused, neglected, involved in and accident or damaged by act of God or other casualty. 4. The purchaser, whether it is a DISTRIBUTOR or direct customer of LI-COR or a DISTRIBUTOR'S customer, packs and ships or delivers the instrument to LI-COR, inc. at LI-COR inc.'s factory in Lincoln, Nebraska, U.S.A. within 30 days after LI-COR, inc. has received written notice of the defect. Unless other arrangements have been made in writing, transportation to LI-COR, inc. (by air unless otherwise authorized by LI-COR, inc.) is at customer expense. 5. No-charge repair parts may be sent at LI-COR, inc.'s sole discretion to the purchaser for installation by purchaser. 6. LI-COR, inc.'s liability is limited to repair or replace any part of the instrument without charge if LI-COR, inc.'s examination disclosed that part to have been defective in material or workmanship. There are no warranties, express or implied, including but not limited to any implied warranty of merchantability of fitness for a particular purpose on underwater cables or on expendables such as batteries, lamps, thermocouples, and calibrations. Other than the obligation of LI-COR, inc. expressly set forth herein, LI-COR, inc. disclaims all warranties of merchantability or fitness for a particular purpose. The foregoing constitutes LI-COR, inc.'s sole obligation and liability with respect to damages resulting from the use or performance of the instrument and in no event shall LI-COR, inc. or its representatives be liable for damages beyond the price paid for the instrument, or for direct, incidental or consequential damages. The laws of some locations may not allow the exclusion or limitation on implied warranties or on incidental or consequential damages, so the limitations herein may not apply directly. This warranty gives you specific legal rights, and you may already have other rights which vary from state to state. All
15 warranties that apply, whether included by this contract or by law, are limited to the time period of this warranty which is a twelve-month period commencing from the date the instrument is shipped to a user who is a customer or eighteen months from the date of shipment to LI-COR, inc.'s authorized distributor, whichever is earlier. This warranty supersedes all warranties for products purchased prior to June 1, 1984, unless this warranty is later superseded. DISTRIBUTOR or the DISTRIBUTOR'S customers may ship the instruments directly to LI-COR if they are unable to repair the instrument themselves even though the DISTRIBUTOR has been approved for making such repairs and has agreed with the customer to make such repairs as covered by this limited warranty. Further information concerning this warranty may be obtained by writing or telephoning Warranty manager at LI-COR, inc. IMPORTANT: Please return the User Registration Card enclosed with your shipment so that we have an accurate record of your address. Thank you.
16 LI-COR, inc Superior Street P.O. Box 4425 Lincoln, Nebraska U.S.A. Phone: FAX: Toll-free (U.S. & Canada)
SM192/716 STORAGE MODULE INSTRUCTION MANUAL
SM192/716 STORAGE MODULE INSTRUCTION MANUAL REVISION: 6/14/93 COPYRIGHT (c) 1989, 1993 CAMPBELL SCIENTIFIC, INC. WARRANTY AND ASSISTANCE The SM192/716 STORAGE MODULE is warranted by CAMPBELL SCIENTIFIC,
More informationPV3500. Fuel Site Controller. Service Manual OPW Fuel Management Systems Manual M Rev. 1
PV3500 Fuel Site Controller Service Manual 2002 OPW Fuel Management Systems Manual M11-00.03 Rev. 1 OPW Fuel Management Systems - System and Replacement Parts Warranty Statement Effective September 1,
More informationVP Process Inc. Model: VP-EC-RDU Modbus RTU LCD Display
VP Process Inc. Model: Modbus RTU LCD Display User Manual Ver: 2.0 Aug. 2017 P a g e 1 Standard Features Low Power (12-24 VDC) 2.1 x 5mm Barrel Plug, RJ45 and Terminal Block Input On-Board Local Temperature
More informationLudlum Lumic Data Logger Software Manual Version 1.1.xx
Ludlum Lumic Data Logger Software Manual Version 1.1.xx Ludlum Lumic Data Logger Software Manual Version 1.1.xx Contents Introduction... 1 Software License Agreement... 2 Getting Started... 5 Minimum
More informationSC32A OPTICALLY ISOLATED RS232 INTERFACE INSTRUCTION MANUAL
SC32A OPTICALLY ISOLATED RS232 INTERFACE INSTRUCTION MANUAL REVISION: 1/93 COPYRIGHT (c) 1987, 1993 CAMPBELL SCIENTIFIC, INC. WARRANTY AND ASSISTANCE The SC32A OPTICALLY ISOLATED RS232 INTERFACE is warranted
More informationPCMCIA Flash Card User Guide
R R PCMCIA Flash Card User Guide For the CoreBuilder 3500 System Introduction The CoreBuilder 3500 PCMCIA Flash Card is a 20 MB flash card that you can use to save your system software. When you have saved
More informationWoolich Racing. USB ECU Interface User Guide
Woolich Racing USB ECU Interface User Guide 1) Introduction This user guide covers how to use the Woolich Racing USB ECU Interface. This includes: Connecting the USB ECU Interface into the Bike Harness
More informationFA-2448 SIX POSITION Filter Wheel
15 Discovery Way, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.acton-research.com Operating Instructions Acton Research Corporation FA-2448 SIX POSITION Filter Wheel Rev. 3.05.17
More informationOPERATIONS MANUAL PCM-DOC
OPERATIONS MANUAL PCM-DOC NOTE: This manual has been designed and created for use as part of the WinSystems Technical Manuals CD and/or the WinSystems website. If this manual or any portion of the manual
More informationCOBALT C INSTALLATION GUIDE RFID CONTROLLER ESCORT MEMORY SYSTEMS. High Frequency Passive Radio Frequency Identification Controller
ESCORT MEMORY SYSTEMS COBALT C0405-232-01 RFID CONTROLLER High Frequency Passive Radio Frequency Identification Controller INSTALLATION GUIDE How to Install and Configure Escort Memory Systems Cobalt C0405-232-01
More informationSC532A 9-PIN PERIPHERAL TO RS232 INTERFACE INSTRUCTION MANUAL
SC532A 9-PIN PERIPHERAL TO RS232 INTERFACE INSTRUCTION MANUAL REVISION: 7/02 COPYRIGHT (c) 1998-2002 CAMPBELL SCIENTIFIC, INC. This is a blank page. Warranty and Assistance The SC532A 9-PIN PERIPHERAL
More informationCard Encoder. PC Software. User Manual Software OPW Fuel Management Systems Manual No. M Rev 2
Card Encoder PC Software User Manual Software 5.21 2002 OPW Fuel Management Systems Manual No. M51-01.05 Rev 2 OPW Fuel Management Systems - System and Replacement Parts Warranty Statement Effective September
More informationFTC-200 X-ray Tube Controller Users Manual
Tubes FTC-200 X-ray Tube Controller TUB-MAN-2101 Rev. A 09/09/2009TTUB Table of Contents List of Tables...3 List of Figures...3 Introduction...3 Manual Set...3 About this Manual...4 X-Ray Safety Information...4
More informationMD9 MULTIDROP INTERFACE INSTRUCTION MANUAL
MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL REVISION: 01/05/03 COPYRIGHT (c) 1987-2003 CAMPBELL SCIENTIFIC, INC. This is a blank page. WARRANTY AND ASSISTANCE The MD9 MULTIDROP INTERFACE is warranted by
More informationHVPS-C. High Voltage Power Supply. HVPS-C. Package Contents: Sold Separately. Table of Contents:
High Voltage Power Supply www.modionvacuum.com Package Contents: 1 High Voltage Power Supply/controller Sold Separately The is a High Voltage Power Supply/Controller designed to run MODION ion pumps manufactured
More informationREMOTE FRONT PANEL EMULATION
REMOTE FRONT PANEL EMULATION USER REFERENCE GUIDE 2500 Application Software Series Part Number: 3-9003-170 Revision 1.0 MARCH 1991 EMULATOR GUIDE DANIEL INDUSTRIES, INC. REMOTE FRONT PANEL EMULATION USER
More informationPC 150. Digital Bench Scale. Operation Manual
PC 150 Digital Bench Scale Operation Manual Revision 1.2 September 14, 2000 1996-2000 Transcell Technology, Inc. Contents subject to change without notice. Transcell Technology, Inc. 35 Waltz Drive Wheeling,
More informationUser's Guide. diskette drive. Rev. 6/1/97 Copyright 1997 Micro Solutions, Inc.
diskette drive User's Guide Rev. 6/1/97 Copyright 1997 Micro Solutions, Inc. Micro Solutions, Inc., provides this manual as is, without warranty of any kind, either express or implied. Micro Solutions,
More informationRTDM RUN-TIME VERSION REAL TIME DATA MONITOR INSTRUCTION MANUAL
RTDM RUN-TIME VERSION REAL TIME DATA MONITOR INSTRUCTION MANUAL REVISION: 1/04 COPYRIGHT (c) 1999-2004 CAMPBELL SCIENTIFIC, LTD. Copied under license by Campbell Scientific, Inc. This is a blank page.
More informationSLUG DATA-LOGGER MANUAL. YieldPoint Inc. JULY 2009
SLUG DATA-LOGGER MANUAL YieldPoint Inc. JULY 2009 Copyright 2009 by YieldPoint Inc. The Information contained herein is the exclusive property of YieldPoint Inc., except as otherwise indicated and shall
More informationMacon Plastics, Inc. Solvent Weld SCH 40/80 DWV
Catalog #210SDWV MP Macon Plastics, Inc. & DWV Fittings P R I C E L I S T Solvent Weld /80 DWV Effective Date: 02/02/15 Catalog : 210SDWV Revision: D Supercedes: 209SDWV Not sure if you have a current
More informationOperating Bulletin MODBUS-RTU. The Fastest Flow Controller Company in the World!
Operating Bulletin MODBUS-RTU The Fastest Flow Controller Company in the World! 1 Notice: Alicat Scientific, Inc. reserves the right to make any changes and improvements to the products described in this
More informationOPERATIONS MANUAL PCM-I/O48
OPERATIONS MANUAL PCM-I/O48 NOTE: This manual has been designed and created for use as part of the WinSystems Technical Manuals CD and/or the WinSystems website. If this manual or any portion of the manual
More informationSKM 04. User Manual. 4-Port Keyboard, Mouse and Audio Switch with USB 2.0 Sharing
SKM 04 User Manual 4-Port Keyboard, Mouse and Audio Switch with USB 2.0 Sharing Manage keyboard & mouse operations on four computers over multiple displays Made in U.S.A. www.smartavi.com 1 1-800-AVI-2131
More informationSM4M/SM16M STORAGE MODULE INSTRUCTION MANUAL
SM4M/SM16M STORAGE MODULE INSTRUCTION MANUAL REVISION: 03/00 COPYRIGHT (c) 2000 CAMPBELL SCIENTIFIC, INC. This is a blank page. WARRANTY AND ASSISTANCE The SM4M/SM16M STORAGE MODULE is warranted by CAMPBELL
More informationEmbeddable Digital Video Recorder with Incremental Encoder Interface. Hardware Manual
Embeddable Digital Video Recorder with Incremental Encoder Interface Hardware Manual Model 4012 Ver. 1.0.0 May 2016 SENSORAY p. 503.684.8005 email:info@sensoray.com www.sensoray.com 7313 SW Tech Center
More informationFLAP indicator. Installation manual Version 1.10
FLAP indicator Installation manual Version 1.10 LXNAV d.o.o. Kidričeva 24, 3000 Celje, Slovenia tel +386 592 33 400 fax +386 599 33 522 info@lxnav.com www.lxnav.com 1 Important Notices... 3 1.1 Limited
More informationModel GX-2001 Data Logging Software. User s Guide
Model GX-2001 Data Logging Software User s Guide Part Number: 71-0056RK Edition: First Released: 6/29/2001 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects
More informationDPN-4 Duo. User Manual. 4-Port Dual-Head Displayport KVM switch with USB 2.0 and Audio Sharing
DPN-4 Duo User Manual 4-Port Dual-Head Displayport KVM switch with USB 2.0 and Audio Sharing Access & Control up to 4 Computers from a single Workstation Made in U.S.A. www.smartavi.com 1 1-800-AVI-2131
More informationUSB Ranger 422 User Guide
USB Ranger 422 User Guide Featuring ExtremeUSB Technology USB Ranger 422 Thank you for purchasing the USB Ranger. Please read this guide thoroughly before installation. This document applies to Part Numbers:
More informationUser's Guide. Temperature / Humidity Datalogger. Model 42270
User's Guide Temperature / Humidity Datalogger Model 42270 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment
More informationFES LCD Display Version 1.1
FES LCD Display Version 1.1 LZ design d.o.o., Brod 3D, 1370 Logatec, Slovenia tel +386 59 948 898 info@lzdesign.si www.front-electric-sustainer.com Table of Content 1. Important notices... 3 1.1 Limited
More informationEPSON PreferredSM Limited Warranty Program for the Epson Stylus
Limited Warranty Program for the Epson Stylus Pro 17-inch Wide Format Printers Priority Technical Support Toll-Free Phone Number Security and Peace of Mind CPD-28163R1 Limited Warranty Program for the
More informationGateway Module Programmable in C
User Manual for the HE660CGMx24 Gateway Module Programmable in C Second Edition 09 August 2000 MAN0025-02 MAN0025-02 09 AUG 2000 PAGE 3 PREFACE This manual explains how to use the Horner APG Gateway Module
More informationDPN 4 Duo. User Manual. 4-Port Dual-Head DisplayPort 1.2 KVM Switch with USB 2.0 and Audio Sharing
DPN 4 Duo User Manual 4-Port Dual-Head DisplayPort 1.2 KVM Switch with USB 2.0 and Audio Sharing Access and Control Four Computers with 2 DisplayPort Monitors each Using One KVM Workstation with Two DisplayPort
More informationRelay Board. User Manual. 1.0, Oct 2013
Relay Board User Manual 1.0, Oct 2013 This work is licensed under the Creative Commons Attribution-Share Alike 2.5 India License. To view a copy of this license, visit http://creativecommons.org/licenses/by-sa/2.5/in/
More informationINSTRUCTION MANUAL. SM4M/SM16M Storage Module. Revision: 3/01. Copyright (c) Campbell Scientific, Inc.
INSTRUCTION MANUAL SM4M/SM16M Storage Module Revision: 3/01 Copyright (c) 2000-2001 Campbell Scientific, Inc. Warranty and Assistance The SM4M/SM16M STORAGE MODULE is warranted by CAMPBELL SCIENTIFIC,
More information1. Introduction... 1 Features... 1 Package Contents... 1 System Requirements... 1 LED Status... 2
- i - Table of Contents 1. Introduction... 1 Features... 1 Package Contents... 1 System Requirements... 1 LED Status... 2 2. Installation... 3 Windows 7/ Vista... 3 Windows XP... 5 Windows 2000... 7 Windows
More informationMotorized Filter Wheel FW-MOT-12.5 / FW-MOT-25
Motorized Filter Wheel FW-MOT-12.5 / FW-MOT-25 Andover Corporation 4 Commercial Drive Salem, New Hampshire 03079-2800 Tel: (603) 893-6888 US Toll Free: (888) 893-9992 Fax: (603) 893-6508 Email: techstaff@andovercorp.com
More informationUser s Guide. OM-CP-HITEMP140-M12 High Temperature Data Logger with an M12 Probe Connector
User s Guide OM-CP-HITEMP140-M12 High Temperature Data Logger with an M12 Probe Connector OM-CP-HITEMP140-M12 Product Overview The OM-CP-HITEMP140-M12 is a rugged and versatile high temperature data logger
More informationAirPro Surveyor 2 Manual
AirPro Surveyor 2 Manual AirPro Surveyor Specifications Table of Contents Size 3/8 x 7 1/2 x 4 3/8 Weight 4.6 lbs. 2094 g Dynamic Range 1-1000 ml/min. total flow/constant flow Flow Capacity (8 Hrs.) 1000
More informationEASON TECHNOLOGY. IO8 & IO24 Break-Out Module
EASON TECHNOLOGY IO8 & IO24 Break-Out Module p/n 50-00180-01 Revision1.2 Eason Technology, Inc. 7975 Cameron Dr. Bldg 300 Windsor, CA 95492 Phone (707) 837-0120 FAX (707) 837-2742 http://www.eason.com
More informationNOTE: The F2 button and the 4 LED annunciators do not function on the LD-ACF-I. To use these features, ask about the LD-ACF-R4/R4A.
Large display AC frequency indicator The is a sophisticated microprocessorbased indicator designed specifically to monitor AC frequency. Intuitive scrolling text menus, (activated from the front panel),
More informationSC532 9-Pin Peripheral to RS232 Interface
SC532 9-Pin Peripheral to RS232 Interface User Guide Issued 3.2.93 Copyright 1993 Campbell Scientific, Inc. Copied under licence by Campbell Scientific Ltd. Guarantee This equipment is guaranteed against
More informationUSB Ranger 110/410 User Guide
USB Ranger 110/410 User Guide Featuring ExtremeUSB Technology USB Ranger 110/410 Thank you for purchasing the USB Ranger. Please read this guide thoroughly before installation. This document applies to
More informationThe EB7-4W plugs onto one- or two-channel speaker or headset stations as illustrated in Figure 1. EB7-4W. Option. 4-Wire. Option
KB/HB-Series INSTALLATION INSTRUCTIONS EB7-4W Module Installation Clear-Com s EB7-4W 4-Wire Option module can be added to the KB-702, KB- 702GM, KB-701, and HB-702 products. This option allows the speaker
More informationUSB Server User Manual
1 Copyright Notice Copyright Incorporated 2009. All rights reserved. Disclaimer Incorporated shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential
More informationDataPort 250 USB 2.0 Enclosure User s Guide (800)
DataPort 250 USB 2.0 Enclosure User s Guide WWW.CRU-DATAPORT.COM (800) 260-9800 TABLE OF CONTENTS PAGE Package Contents 1 Features and Requirements 2 Installation 4 Trouble Shooting 13 Technical Support
More informationIt s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1
Installation and Operation Guide 70-210043-17 V 1.1 Copyright 2008 Remote Technologies Incorporated All rights reserved. 2 DECLARATIONS 117 612 914 DECLARATION OF CONFORMITY (DOC) The Declaration of Conformity
More informationMTS-2000 USER S MANUAL
MTS-2000 USER S MANUAL USER s MANUAL - March 2010 MTS-2000 METER TEST SYSTEM Pay special attention to the warnings and safety instructions that accompany the above symbol wherever it is found within this
More informationProliphix EPA-60 Installation Guide
Proliphix EPA-60 Installation Guide Rev 1.2 Page 2 of 5 Installation CAUTION THE EPA-60 SHOULD ONLY BE POWERED WITH THE PROLIPHIX POWER SUPPLY INCLUDED WITH THE EPA-60. DO NOT POWER THE EPA-60 WITH ANY
More informationma Input Module. Installation and Operation Guide
780 4-20 ma Input Module Installation and Operation Guide Part #60-9003-064 Copyright 1995. All rights reserved, Isco, Inc. Revision E, April 20, 2011 Foreword This instruction manual is designed to help
More informationUHDN 4P Duo. User Manual. 4-Port Dual Head Ultra 4K-60Hz HDMI KVM Switch with USB 2.0 and Audio Support. Manage 4 computers from a single workstation
UHDN 4P Duo User Manual 4-Port Dual Head Ultra 4K-60Hz HDMI KVM Switch with USB 2.0 and Audio Support Manage 4 computers from a single workstation Made in U.S.A. www.smartavi.com 1 1-800-AVI-2131 TABLE
More informationEPSON Preferred. Priority Technical Support. Toll-Free Phone Number. Security and Peace of Mind. On-Site Repair
EPSON Preferred SM Limited Warranty Program for the Epson Stylus Pro Large Format Printers Priority Technical Support Toll-Free Phone Number Security and Peace of Mind On-Site Repair CPD-20273 Please open
More informationMODBUS MANUAL For the AccUView UV Transmission Monitor
MODBUS MANUAL For the AccUView UV Transmission Monitor HF scientific, inc. 3170 Metro Parkway Ft. Myers, FL 33916 Phone: 239-337-2116 Fax: 239-332-7643 E-Mail: info@hfscientific.com Website: www.hfscientific.com
More informationDVN 16Pro. User Manual. 16-Port DVI-D KVM Switch with Audio and USB 2.0 Sharing
DVN 16Pro User Manual 16-Port DVI-D KVM Switch with Audio and USB 2.0 Sharing Access and Control 16 Computers with One USB keyboard, USB Mouse and DVI-D Monitor Made in U.S.A. www.smartavi.com 1 1-800-AVI-2131
More informationTC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual
Series 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX MODEL: S/N: DATE: Notice! Although every effort has been made to insure that this manual is current and accurate as of date of publication, no guarantee
More informationACT-IR210L IrDA Motherboard Adapter. User s Manual
48511 Warm Springs Blvd., Suite 206, Fremont, CA 94539 Tel: (510) 490-8024 Fax: (510) 623-7268 Web: http://www.actisys.com, E-mail: irda-info@actisys.com ACT-IR210L IrDA Motherboard Adapter Feb. 14, 2006
More informationHigh Temperature Data Logger
OM-CP-HITEMP140 Xxxxx Xxxxxx SERIES High Temperature Data Logger INSTRUCTION SHEET MQS5081/1216 Shop online at omega.com SM e-mail: info@omega.com For latest product manuals: www.omegamanual.info Product
More information2 Welcome and Congratulations
2 Welcome and Congratulations Congratulations on your purchase of the Epson SureColor F7200 64-inch wide printer. Your printer is designed to provide consistent high quality output in the dye sublimation
More informationCM17215HR 100Mb/s Fiber CM17212HR 10/100Mb/s UTP PC/104-Plus Dual Ethernet utilitymodule. User s Manual. BDM Rev. C
CM17215HR 100Mb/s Fiber CM17212HR 10/100Mb/s UTP PC/104-Plus Dual Ethernet utilitymodule User s Manual BDM-610020066 Rev. C ISO9001 and AS9100 Certified CM17215HR 100Mb/s Fiber CM17212HR 10/100Mb/s Twisted
More informationFastForward TM User Guide
Let s play follow the leader! FastForward TM User Guide LG G4010 and G4050 Series Phones Welcome Thank you for purchasing Cingular s FastForward. Now you can easily forward incoming calls made to your
More informationInstruction Manual. HH610-SW Application Software for Portable & Bench Meters
Instruction Manual HH610-SW Application Software for Portable & Bench Meters Dear Customer, Thank you for choosing an Omega product. Please read this instruction manual carefully before using the software.
More informationSonicWALL CDP 2.1 Agent Tool User's Guide
COMPREHENSIVE INTERNET SECURITY b SonicWALL CDP Series Appliances SonicWALL CDP 2.1 Agent Tool User's Guide SonicWALL CDP Agent Tool User s Guide Version 2.0 SonicWALL, Inc. 1143 Borregas Avenue Sunnyvale,
More informationOctTemp2000. Data Logger Manual
OctTemp2000 Data Logger Manual Table of ContentsData Logger Manual Overview... 2 Other Documentation... 2 Contacting Us... 2 Introducing the OctTemp2000... 3 Device Overview... 3 Display Overview... 4
More informationFastForward User Guide
Let s play follow the leader! FastForward User Guide Nokia 3100, 3200, 6100, 6200 & 6800 Series Phones Welcome Thank you for purchasing Cingular s FastForward. Now you can easily forward incoming calls
More informationMiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE
MiT MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE OF A-LMS 24 Architectural Lighting Management System Part number A000230-xxx Manual Version 1.0 MOVING image TECHNOLOGIES,
More informationRS422 PORT SWITCHER REMOTE CONTROL PANEL
12843 Foothill Blvd. Suite C Sylmar, California 91342 V: 818.898.3380 F: 818.898.3360 sales@dnfcontrols.com Model No. SW32PS-RCP RS422 PORT SWITCHER REMOTE CONTROL PANEL User Manual Rev 1.01 TABLE OF
More informationCAT5 Extender User Manual
CAT5 Extender User Manual P73228 F1D084 Introduction Thank you for purchasing the Belkin Components CAT5 KVM Extender! The CAT5 KVM Extender allows users to control their computer or KVM switch from up
More informationDICKSON MP100 DICKSON. Operation Manual. Applications. Product. Specifications. Product. Contents:
MP100 Operation Manual Contents: Accessories Warranty / The MP100 creates a NETWORK of Monitoring s. Display Loggers (SM101, SM150, SM175, TM121, TM125) Data Loggers (SX100, TX120, SP100, SP150, TP120,
More informationCMR Quick Start Guide. CMR-8500 DVB IP Encapsulator. Part Number MN-CMR68500-QSG REV. 1
CMR-8500 Quick Start Guide CMR-8500 DVB IP Encapsulator Part Number MN-CMR68500-QSG REV. 1 Copyright Comtech EF Data, 2008. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7th Street,
More informationOP8/16 Optoisolated Digital Input Board User's Manual
OP8/16 Optoisolated Digital Input Board User's Manual Real Time Devices USA, Inc. Accessing the Analog World Publication No. OP16-9742 OP8/16 User's Manual REAL TIME DEVICES USA 820 North University Drive
More information16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch
12 Omnitron Systems Technology, Inc. Omnitron Systems Technology, Inc. 1 FlexSwitch TM 600X 16/24 Port /0 -Sensing Dual Speed Ethernet Switch User s ual 27 Mauchly #201, Irvine, CA 92618 (949) 250-65 Fax:
More informationUser's Manual. Model Heavy Duty Datalogging Module with Windows Software
User's Manual Model 380340 Heavy Duty Datalogging Module with Windows Software Stores data for later recall and analysis Can be used with any Extech Heavy Duty meter Selectable recording interval Battery
More informationPCONNECTCE FOR POCKET PC HANDHELD SOFTWARE SUPPORT FOR CAMPBELL SCIENTIFIC DATALOGGERS VERSION 1.1 INSTRUCTION MANUAL
PCONNECTCE FOR POCKET PC HANDHELD SOFTWARE SUPPORT FOR CAMPBELL SCIENTIFIC DATALOGGERS VERSION 1.1 INSTRUCTION MANUAL REVISION: 8/03 COPYRIGHT 2001-2003 CAMPBELL SCIENTIFIC, INC. Software Copyright MeasureTek,
More informationAWS-QC Torque Tester
AWS-QC Torque Tester USER'S GUIDE March, 2009 ADVANCED WITNESS SERIES, INC. 910 BERN COURT #100 SAN JOSE, CA 95112 (408) 453-5070 www.awitness.com CONTENTS 1 CONTENTS CONTENTS... 1 INTRODUCTION... 2 Description...
More informationVideo Compression H.264
Video input format Video Compression H.264 MENU OSD NTSC or PAL (Auto-detect) English Record Resolution 720x480 (NTSC) Recording Frame Rate 2, 4, 6/8, 13/15, 25/30 fps Video Recording Mode Schedule Continuous,
More informationAdvanced 4/8 Port Secure KM Switch
Document ID: DOC-IPG-2007 Revision: 1.10 Release Date: February 17th, 2017 Advanced 4/8 Port Secure KM Switch USER MANUAL SKMN-4S SKMN-4S-P SKMN-8S SKMN-8S-P 4-Port Secure KM with Audio 4-Port Secure KM
More informationHP Worldwide Limited Warranty and Technical Support
HP Worldwide Limited Warranty and Technical Support HP Hardware Limited Warranty Limited Warranty Period This HP Hardware Limited Warranty gives you, the customer, express limited warranty rights from
More informationHP Limited Warranty Statement Printers and Imaging Products
HP Limited Warranty Statement Printers and Imaging Products Extent of Limited Warranty a. Hewlett-Packard (HP) warrants to the end-user customer that the HP products will be free from defects in material
More information500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System
Market Central www.secureswitch.com 500 Business Center Drive Pittsburgh, PA 15205 USA 412.494.2800 CAGE 1BGJ7 SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System July, 2014 COMPLETE 2
More informationINSTRUCTION MANUAL. SC532 9-Pin Peripheral to RS232 Interface. Revision: 8/92. Copyright (c) Campbell Scientific, Inc.
INSTRUCTION MANUAL SC532 9-Pin Peripheral to RS232 Interface Revision: 8/92 Copyright (c) 1988-1992 Campbell Scientific, Inc. Warranty and Assistance The SC532 9-Pin Peripheral to RS232 Interface is warranted
More informationzpen-1080p Features zpen-1080p Layout
1 zpen-1080p Features CMOS image sensor with Low Light sensitivity HD 1080P up to 30fps, 720P up to 60fps H.264 compression Built-in micro SD card, supports up to 32GB One button operation Easily download
More informationCM17215HR 100Mb/s Fiber CM17212HR 10/100Mb/s UTP PC/104-Plus Dual Ethernet utilitymodule. User s Manual
CM17215HR 100Mb/s Fiber CM17212HR 10/100Mb/s UTP PC/104-Plus Dual Ethernet utilitymodule User s Manual ISO9001 and AS9100 Certified BDM-610020066 Rev. E CM17215HR 100Mb/s Fiber CM17212HR 10/100Mb/s Twisted
More informationADVANCED 4/8-PORT SECURE KM SWITCH
ADVANCED 4/8-PORT SECURE KM SWITCH USM-2S0-1M0 REV: 1.1 DATE: 09/11/2017 1 2 3 4 SS4P-KM-U SECURE KM SWITCH 4 PORT W/ AUDIO MODELS: SS4P-KM-U SS4P-KM-UCAC SS8P-KM-U SS8P-KM-UCAC 4-Port Secure KM Switch
More informationINSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE
INSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE TeleMatrix Copyright 2005 COMPLIANCE AND SAFETY As specified by FCC regulation, we are required to inform you of specific governmental
More informationUser Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276
User Guide Model 42265 Temperature Datalogger Kit Model 42275 Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276 Introduction Congratulations on your purchase of Extech Instrument
More informationUSB Ranger Fiber Optic USB 2.0 Extender. User Guide
USB Ranger 2224 Fiber Optic USB 2.0 Extender User Guide Thank you for purchasing the USB Ranger 2224. Please read this guide thoroughly. This document applies to Part Numbers: 00-00260, 00-00261, 00-00262,
More informationRemote Control for Inverter RC-200. Manual. Please read this manual before operating your RC-200 Remote Control
Remote Control for Inverter RC-200 Owner's Manual Please read this manual before operating your RC-200 Remote Control Owner's Manual Index SECTION 1 Safety...3 SECTION 2 Description...3 SECTION 3 Layout
More informationQuick Installation Guide TU2-700
Quick Installation Guide TU2-700 Table of of Contents Contents English... 1. Before You Start... 2. Hardware Installation... 1 1 2 Troubleshooting... 3 Version 01.16.2006 1. Before You Start Package Content
More informationUÊ, Ê* - 1 Ê Ê Ê " /",Ê
Instruction Manual VDV Distance Meter VDV501-089 ENGLISH Español pg. 6 Français pg. 12 User RG-6 Cat3 RG-11 Cat5e RG-59 Cat6 Short ft m Voltage! pf/ READY www.kleintools.com ENGLISH VDV Distance Meter
More informationTrendSense. Instructions for Use. TrendSense and TrendSense Communicator
Instructions for Use TrendSense and TrendSense Communicator Copyright and contact information Consult Instructions for Use NONIN makes no claim for use of the product other than for those uses specified
More informationVSS700. Regional Sales Office 139 S. Fairlane Ave. Elmhurst, IL Sales: Fax: The EZ Preg Checker
VSS700 The EZ Preg Checker www.ezpregchecker.com Regional Sales Office 139 S. Fairlane Ave. Elmhurst, IL 60126 Sales: 800-617-0503 Fax: 630-626-3759 Main Office/Service Dept. 7861 SW Ellipse Way Stuart,
More informationDCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies
DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies M51A Option: Isolated Analog Programming Manual Power Supplies Elgar Electronics Corporation 9250 Brown Deer Road San Diego, CA 92121-2294 1-800-73ELGAR
More informationCONTENTS CONTENTS AWS-4050 Guide
CONTENTS 1 CONTENTS CONTENTS...1 INTRODUCTION...2 Description...2 System Specifications...2 OPERATION...3 Display Operation...3 nction...4 Back Panel Inputs...4 Transducer Input (12-pin connector)...4
More informationTRENDnet User s Guide. Cover Page
Cover Page Table of Contents Contents Product Overview... 2 Package Contents... 2 Features... 2 Product Hardware Features... 3 Application Diagram... 4 Installation - Hardware... 4 Adapter... 4 Fiber Cable...
More informationSetup and Users Manual
Setup and Users Manual TSHARC 12v Touch Screen Controller Board Supports 4-, 5- & 8-Wire Analog Resistive Touch Screens Supports RS-232 and PS/2 Version 1.1R Document Revision and Copyright Document Name:
More informationPIM-Mini Pulsed Current Source Operation Manual
PIM-Mini Pulsed Current Source Operation Manual Directed Energy, Inc. 1609 Oakridge Dr., Suite 100, Fort Collins, CO 80525 (970) 493-1901 sales@ixyscolorado.com www.ixyscolorado.com Manual Document 7650-0007
More informationUSB-A to Serial Cable
26-949 User s Guide 6-Foot (1.82m) USB-A to Serial Cable Please read this user s guide before using your new cable. 2/2 Package contents USB-A to Serial Cable User s Guide Driver CD Quick Start Features
More informationTB-100 ControLynx Terminal Block
TB-100 ControLynx Terminal Block TECHNICAL MANUAL Version 1.3 September 2006 Copyright This technical manual and the equipment, firmware and software described herein are copyrighted by INTENT DIGITAL
More information