1 User Manual FMUX01(A) SNMP Upgrade Procedure
2 FMUX01(A) SNMP Upgrade Procedure Version 1.0 June 2004 CTC Union Technologies Co.,Ltd All rights reserved The contents of this document are subject to change without notice.
3 1.0 Introduction The purpose of this document is to outline the procedures and pitfalls in upgrading the SNMP of the FMUX01 (and FMUX01A). 1.1 Preconditions The FMUX01 must be using FPGA version 3.3 and the firmware version must be at least If an SNMP option is being installed for the first time, now would be the time to upgrade the operational firmware. As of this writing, the release version is 1.16B. This operational firmware upgrade is support by chip replacement only. The original SNMP release version for the FMUX01 was version The SNMP is upgraded by TFTP. The SNMP agent provides the ability to upload the new code, re-flash the flash memory and reboot with the new SNMP operational code. 1.2 Items required a. The FMUX01 unit with SNMP option installed and network connection. Version 1.00 to be upgraded to version b. A Windows based PC with a network connection and with at least one free Com port, telnet and terminal emulation software (such as HyperTerminal). c. Serial console cable (RJ-45 to DB9F) d. Ethernet UTP cables e. SNMP ver binary image file f. CTC Union TFTP server for Windows (optional) 2.0 Equipment Setup The upgrade procedure could possibly have effect on the traffic passing through an online FMUX01 unit. It is recommended that the unit be taken offline for maintenance. Obviously, changing of FPGA code or firmware requires opening the unit and it must be powered off and disconnected from power mains before opening. The procedure for removing modules and opening the unit is all outlined in the User's Manual and will not be repeated here. Two connections are required between the PC that will do the upgrade and the FMUX01 that will be upgraded. First, a console connection, with terminal emulation program such as HyperTerminal with settings of 19.2K baud, 8 bits, no parity, 1 stop bit, and no flow control. The second connection is an Ethernet connection, either through a network or with a direct connection and crossover UTP cable. Check the Ethernet settings of the FMUX01 through the console mode. Either change the settings to match the network settings of your PC or set the PC's settings to match the FMUX01's network settings. In the following example, we are on a network with a subnet mask of and a default gateway of Our PC is set with an IP address of and our FMUX01 has an IP address of
4 3.0 Setup the FMUX01 The following screens will show the detailed procedures to setup the networking for the FMUX01 and prepare for TFTP upgrade of the SNMP. Once the console port is connected to a terminal, the following screen will display. ** Welcome to FMUX-01 NMS System ** Press the 'Enter' key on the terminal to bring up the main screen. ******************************************** **** CTC UNION TECHNOLOGIES CO.,LTD **** **** FMUX-01 CONSOLE MODE Ver 1.16b **** **** **** ******************************************** 1. Local Login 2. Remote Login Select item #1, 'Local Login' LOCAL ******************************************** **** CTC UNION TECHNOLOGIES CO.,LTD **** **** FMUX-01 CONSOLE MODE Ver 1.16b **** **** **** ******************************************** 0. Logout 1. Display System Status 2. Define System Parameter 3. Alarm Buffer Display 4. Performance Display 5. ACO (Alarm Cut-Off) Please select the item number. Select item #2, 'Define System Status' 2
5 The Define System menu is displayed. LOCAL <<< Define System >>> 1. System Config 2. Optical Port Config 3. Port 1 Config [ E1 75 ] 4. Port 2 Config [ E1 120 ] 5. Port 3 Config [ N/A ] 6. Port 4 Config [ LAN ] [ Loss ] 7. Date & Time 8. SNMP Card Config Press item #8, 'SNMP Card Config' LOCAL <<< SNMP Card Config >>> 1. SNMP Agent Config 2. Manager Config 3. TFTP and Flash 4. Save and Restart Here are the items we need to set and execute to complete our upgrade. First configure the agent's IP, subnet, gateway and IP address of the TFTP server. Enter the path to the upgrade image file located on the TFTP server. In our example, we have extracted and placed the binary image file on the root of our "E" drive. Placing it in a root directory simplifies our entry in the Agent configuration. Press the #1 key to enter the Agent Configuration. 3
6 SNMP Agent Configuration LOCAL <<< SNMP Agent Config >>> 1. IP Address [ ] 2. Subnet Mask [ ] 3. Gateway IP [ ] 4. TFTP Server IP [ ] 5. TFTP Server Path [/snmp.bin] The peculiarities of the interface may make the entry of IP addresses seem cumbersome at first, but once you get the hang of it, it's pretty easy. Enter every number of the IP address, including zeros and do not enter any 'dots'. So, for our IP address of , we will press #1 and then key in: [Enter] There it is, all in one sweep, no spaces, no dots and no backspacing. Continue with the subnet mask, gateway, TFTP server's IP and path to binary file on TFTP server. Remember that pathnames in UNIX use forward slashes if you have a UNIX or LINUX TFTP server and that Windows uses backslashes in pathnames. Here are our results. LOCAL <<< SNMP Agent Config >>> 1. IP Address [ ] 2. Subnet Mask [ ] 3. Gateway IP [ ] 4. TFTP Server IP [ ] 5. TFTP Server Path [e:\snmp111.bin] After filling in all of the Agent information, press 'ESC' to go back to the SNMP card configuration page. 4
7 Back to the SNMP card configuration page. LOCAL <<< SNMP Card Config >>> 1. SNMP Agent Config 2. Manager Config 3. TFTP and Flash 4. Save and Restart Press #4, to save the previous settings and restart the SNMP module. Takes about a minute. LOCAL <<< SNMP Card Config >>> 1. SNMP Agent Config 2. Manager Config 3. TFTP and Flash 4. Save and Restart Save To SNMP card Wait... Now we have the SNMP agent configured for the network and ready for upgrade. Next we need to set the TFTP server. As you saw from the previous configuration, we have placed the upgrade binary file on our "E" drive, in the root directory. The file is called snmp111.bin. All that is needed now is to run the TFTP daemon program for Windows. It's a simple little proggy!! No configuration is required, just run it. Now your PC is a TFTP server! 5
8 Here is what the TFTP server looks like when it is running. SNMP Upgrade Procedure / FMUX01(A) Now that we have our TFTP server set and the FMUX01 ready, open up a command window on the PC and ping the FMUX01, just to make sure the network connection is good. Go back through the console port menu systems again until you arrive at the 'SNMP Card Config' page. Press #3 'TFTP and Flash'. Press it JUST ONCE!! If you go to the TFTP server screen, you should see the server serving up the binary file to the IP address of the FMUX01 and finish with an 'OK' Status. There will not be any indication on the console screen of the FMUX01 that anything has happened. Watch the 'Activity' LED of the SNMP on the front panel of the FMUX01. When the LED returns to a constant 1 blink per second, the SNMP agent has rebooted. You can now 'Close' the TFTP server. 6
9 OK, now let's verify the version number of the SNMP. To do that, we must connect via Telnet to the FMUX01. Click the Windows 'Start' button and select 'Run'. In the Run window, type in: telnet [Enter] (Of course use the IP address for your network setup.) Enter the 'superuser' password (1021). The version of SNMP is displayed in the header message. In our case the SNMP version is This completes the SNMP upgrade procedure. 7
10 Fiber Series Units CTC Union Technologies Co., Ltd. Far Eastern Vienna Technologies Center (Neihu Technology Park) 8F, No. 60, Zhouzi St., Neihu, Taipei, Taiwan Phone:(886) Fax:(886)
User Manual FRM301 SNMP Upgrade Procedure
User Manual FRM301 SNMP Upgrade Procedure FRM301 SNMP Upgrade Procedure Version 1.0 July 2005 CTC Union Technologies Co.,Ltd. 2005 All rights reserved The contents of this document are subject to change
More informationFRM220 NMC Upgrade Procedure
The information within this document is intended for experienced service personnel with knowledge of TCP/IP networking, PC networking configuration, serial terminal configuration and operation. Failure
More informationFMUX01A/Plus Port Based VLAN Application Note
FMUX01A/Plus Port Based VLAN Application Note The information within this document is intended for experienced service personnel with knowledge of TCP/IP networking, PC networking configuration, serial
More informationFRM220 NMC-R2 Upgrade Procedure
The information within this document is intended for experienced service personnel with knowledge of TCP/IP networking, PC networking configuration, serial terminal configuration and operation. Failure
More informationNova series update F/W & Boot code from Boot Utility
Nova series update F/W & Boot code from Boot Utility Purpose: Update firmware/boot code from Boot Utility Product Affect: Nova 20S, Nova 20R, Nova 26S, Nova 26R, Nova 27S, Nova 29S, Nova 30S, Nova 30R,
More informationCTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60, Zhouzi St., Neihu, Taipei 114, Taiwan
CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60, Zhouzi St., Neihu, Taipei 114, Taiwan T +886-2-26591021 F +886-2-26590237 E sales@ctcu.com techsupport@ctcu.com
More informationUser can upgrade the firmware directly using the Web or Console.
17. Firmware Upgrade User can upgrade the firmware directly using the Web or Console. Firmware name (current) and applied model: V3K31257_en.all:Vigor 3300B+ 2.5.7 English version. V3K31257_cn.all:Vigor
More informationField Procedure For Installation Of A WEB/SNMP Card For enotify
Field Procedure For Installation Of A WEB/SNMP Card For enotify Eaton Electrical Inc. Page 1 8/11/2006 Requirements The UPS Firmware must have the following minimum firmware, see table below (It is recommended
More informationManaging Controller Software and Configurations
CHAPTER 8 Managing Controller Software and Configurations This chapter describes how to manage configurations and software versions on the controllers. This chapter contains these sections: Transferring
More informationProcedure to upgrade the Boot Code, program firmware and Web image by using console port & TFTP
Procedure to upgrade the Boot Code, program firmware and Web image by using console port & TFTP Command explanation: While reboot AP in console mode to press x, it will into command mode like as .
More informationService Bulletin Rev Firmware Upgrade for ACRC100 Series
Rev. 3.1.0 Firmware Upgrade for ACRC100 Series Objective This Service Bulletin defines the procedure for upgrading the firmware for the InRow ACRC to version AOS 3.1.3 and APP 3.1.0. This upgrade is mandatory
More informationRC001-NMS1 (REV.C) User Manual
RC001-NMS1 (REV.C) User Manual Raisecom Technology Co., Ltd (08/2005) CONTENTS Chapter 1. System Overview...2 1.1 RC002-16 Chassis...2 1.2 RC001-NMS1 Master Network Management Module...2 1.3 RC001-NMS2
More informationHow to Upgrade or Recover the Firmware of the UC-7400 Series Embedded Computers
How to Upgrade or Recover the Firmware of the UC-7400 Series Embedded Computers Bruce Chen, Project Supervisor, Moxa Technical Support Dept. Moxa offers the boot loader utility for firmware upgrade or
More informationSecurely manage data center and network equipment from anywhere in the world.
LES1208A-R2 LES1216A-R2 LES1232A LES1248A-R2 8-/16-/32-/48-Port Advanced Console Servers QS Guide Securely manage data center and network equipment from anywhere in the world. Customer Support Information
More informationSTE100A Single Port IP to Serial Device Server
STE100A Single Port IP to Serial Device Server CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St., Neihu, Taipei 114, Taiwan T +886-2-26591021
More informationUSER MANUAL E1U-ET100. Ethernet over Unframed E1 Bridge Line Card For ERM01
USER MANUAL E1U-ET100 Ethernet over Unframed E1 Bridge Line Card For ERM01 CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60, Zhouzi St. Neihu, Taipei,
More informationGW1000 User s Guide. Revision 1.04 Mar 30, 2008
GW1000 User s Guide Revision 1.04 Mar 30, 2008 Website: www.datalink-networks.com Tel : (604) 632-4278 / (866) 709-6390 Table of Contents 1.0 GW1000 General Operation & Applications... 3 2.0 Hardware Specifications...
More informationTFC-1600MM Media Conversion System. Management Configuring Guide
TFC-1600MM Media Conversion System Management Configuring Guide CONFIGURING THE SYSTEM This chapter provides network managers and system administrators with information about how to configure the Media
More informationDocument Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index
Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index Technical Specifications 1 Installation Procedure 1 LED Indications 2 Configuration Procedure Configuration
More informationSD24GS. 24-Port Web Smart Gigabit Ethernet Switch. User s Manual
SD24GS 24-Port Web Smart Gigabit Ethernet Switch User s Manual FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC
More informationQ&As. Interconnecting Cisco Networking Devices Part 1. Pass Cisco Exam with 100% Guarantee
640-822 Q&As Interconnecting Cisco Networking Devices Part 1 Pass Cisco 640-822 Exam with 100% Guarantee Free Download Real Questions & Answers PDF and VCE file from: 100% Passing Guarantee 100% Money
More information28-Port 10/100/1000Mbps with. 4 Shared SFP Managed Gigabit Switch WGSW / WGSW-28040P. Quick Installation Guide
28-Port 10/100/1000Mbps with 4 Shared SFP Managed Gigabit Switch WGSW-28040 / WGSW-28040P Quick Installation Guide Table of Contents 1. Package Content... 3 2. Requirements... 4 3. Terminal Setup... 5
More informationUpgrade 6081RC Firmware
6081RC Upgrade procedure for firmware and CoMon bootloader Date Action Sign-off 1/22/2009 Write initial upgrade procedure for firmware & CoMon bootloader Nathan Meyer 1/27/2009 Edit to simplify procedure
More informationConfiguration Guide. Upgrading AOS Firmware L1-29.1D July 2011
61200990L1-29.1D July 2011 Configuration Guide This configuration guide explains how to update your ADTRAN Operating System (AOS) firmware using the AOS Web-based graphical user interface (GUI) with Trivial
More informationSecurely manage data center and network equipment from anywhere in the world.
November 2009 LES1208A LES1216A LES1248A 8-/16-/48-Port Advanced Console Servers Quick Start Guide Securely manage data center and network equipment from anywhere in the world. Customer Support Information
More informationD-Link (Europe) Ltd. 4 th Floor Merit House Edgware Road London HA7 1DP U.K. Tel: Fax:
Product: DFL-500 Internet Firewall Index Setup Introduction...2 Set Up Using Web Configurator...3 Setting Up Internal IP Address using CLI...4 Setting UP External IP Address Manually Using CLI...4 How
More informationMonitor and Manage your Power System with Ease.
People with Passion Best in Class Technology Power System Focus Monitor and Manage your Power System with Ease. TESLA 3000 Power System Recorder Accessing Multiple Remote Recorders on a Single Modem Call
More informationS38 Basic Configuration
S38 Basic Configuration Contents 1 Web Login Summary...1 1.1 Overview...1 1.2 Management IP/ Route Configuration...1 1.3 User Configuration...2 1.4 Http Configuration...2 1.5 Web Login...3 2 Firmware upgrade...5
More informationFMUX04E. Fiber Optical Multiplexer 4 Channel Fixed G.703 E1, DS1(T1) Plus Wire Speed 100M Ethernet SNMP Manageable (Option)
FMUX04E Fiber Optical Multiplexer 4 Channel Fixed G.703 E1, DS1(T1) Plus Wire Speed 100M Ethernet SNMP Manageable (Option) The information contained in this document is subject to change without prior
More informationFRM220-NMC Network Management Controller
FRM220-NMC Network Management Controller CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St. Neihu District Taipei 114 Taiwan Tel: +886-2-26591021
More information**Note that this must be run from a PC on the same network segment as the NetBotz device, and the NetBotz device MUST be connected to the network.
**Note that this must be run from a PC on the same network segment as the NetBotz device, and the NetBotz device MUST be connected to the network.** 1. Download the correct drivers for the USB to Serial
More informationFVT Slot Managed Converter Chassis w/ Redundant Power Supply User Manual
FVT-5000 16-Slot Managed Converter Chassis w/ Redundant Power Supply User Manual Ver 1.00-0701 Table of Contents 1. INTRODUCTION... 1 1.1. FEATURES... 1 1.2. SOFTWARE FEATURE... 2 1.3. MANAGEMENT METHODS...
More information8.9.2 Lab: Configure an Ethernet NIC to use DHCP in Windows Vista
8.9.2 Lab: Configure an Ethernet NIC to use DHCP in Windows Vista Introduction If Vista is not available in your classroom, you may complete this lab by viewing the figures in this document. Print and
More information24-Port Gigabit + 4-Port 10G SFP+ Slot. Layer 3 Stackable Managed Switch XGS Quick Installation Guide
24-Port Gigabit + 4-Port 10G SFP+ Slot Layer 3 Stackable Managed Switch XGS3-24042 Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Switch Management... 4 3. Requirements... 5 4.
More informationEEG ComCC 1250m Modem Data Multiplexer
EEG ComCC 1250m Modem Data Multiplexer Product Manual EEG Enterprises, Inc. 586 Main Street Farmingdale, New York 11735 TEL: (516) 293-7472 FAX: (516) 293-7417 Copyright EEG Enterprises, Inc. 2010 All
More informationTable of Contents. NBC User's Manual
User's Manual User's Manual Table of Contents 1. Connections and Power... 3 1.1. Connections and Power for WSXXXX_BR products... 3 2. Initial Configuration... 4 2.1. NBC Network Configuration... 4 2.2.
More informationSetting Up Your Cisco Unified Videoconferencing 3500 Gateway
CHAPTER 2 Setting Up Your Cisco Unified Videoconferencing 3500 Gateway This section describes the following topics: Physical Description, page 2-1 Preparing for Installation of the Cisco Unified Videoconferencing
More informationRS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual
RS-232/422/485 to Copper or Fiber Ethernet Converter User s Manual Table Of Contents TABLE OF CONTENTS... 1 INTRODUCTION... 3 PRODUCT OVERVIEW... 3 PRODUCT FEATURES... 3 PACKING LIST... 4 LED INDICATORS...
More informationApplication Note #5494 Upgrading Plus Ethernet Radio Firmware September 9, 2013
Application Note #5494 Upgrading Plus Ethernet Radio Firmware September 9, 2013 The Plus Ethernet transceivers share a common firmware upgrade platform and process using the FreeWave TFTP Server and a
More informationfor VoIP Gateway Series
Smart Web Manager for VoIP Gateway Series www.addpac.com AddPac Technology 2010, Sales and Marketing Contents Web Connection Main Page Layout System Configuration Language, WAN Setup, LAN Setup, NAT, NTP,
More informationRestoring an SP Boot Image
AX100-Series Restoring an SP Boot Image Revision A01 June 9, 2004 This document explains how to restore an SP s boot image. Read it when an SP does not start properly and its fault light blinks four times
More informationCCNA2 Chapter 1 Practice
CCNA2 Chapter 1 Practice Where should a crossover UTP cable be used? (Choose 2) To connect two PCs together directly. To connect a router to an Ethernet switch. To connect a PC to an Ethernet switch. To
More informationRC NMS1 (REV.B) User Manual. Beijing Raisecom Science & Technology Co., Ltd
RC004-16 NMS1 (REV.B) User Manual Beijing Raisecom Science & Technology Co., Ltd April 2005 1 Catalogue CHAPTER 1 SYSTEM COMPONENTS AND ITS INTRODUCTION...3 1 RC004-16 CHASSIS...3 2 RC004-16 NMS1 MASTER
More informationLab Router Configuration Using Setup Instructor Version 2500
Lab 2.2.1 Router Configuration Using Setup Instructor Version 2500 Objective Use the System Configuration dialog (setup). Establish some basic router configurations. Background/Preparation A new router
More informationTABLE OF CONTENTS COPYRIGHT INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION
TABLE OF CONTENTS COPYRIGHT...2 1. INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION...3 2. MFP SERVER INSTALLATION...5 PREPARATION...5 CONFIGURATION SOLUTION TABLE...5
More informationZyWALL 10W. Internet Security Gateway. Quick Start Guide Version 3.62 December 2003
Internet Security Gateway Quick Start Guide Version 3.62 December 2003 Introducing the ZyWALL The is the ideal secure gateway for all data passing between the Internet and the LAN. By integrating NAT,
More information16/24/48-Port 10/100/1000T + 2/4-Port 100/1000X SFP Managed Switch GS T2S/GS T2S/GS T4S. Quick Installation Guide
16/24/48-Port 10/100/1000T + 2/4-Port 100/1000X SFP Managed Switch GS-4210-16T2S/GS-4210-24T2S/GS-4210-48T4S Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4 3.
More informationLongshine Technologie Europe GmbH
Longshine Technologie Europe GmbH www.longshine.de TABLE OF CONTENTS COPYRIGHT...2 1. INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION...3 2. MFP SERVER INSTALLATION...5
More informationSilex SD-320AN-03 Serial Server
GE Healthcare Silex SD-320AN-03 Serial Server Firmware Upgrade Instructions 2106794-001 Revision B Silex SD-320AN-03 Serial Server English 2018 General Electric Company. All Rights Reserved. Publication
More informationSTE100A Single Port IP to Serial Device Server
STE100A Single Port IP to Serial Device Server CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St., Neihu, Taipei 114, Taiwan T +886-2-26591021
More informationConfiguring the Switch with the CLI-Based Setup Program
Configuring the Switch with the CLI-Based Setup Program Accessing the CLI Through Express Setup, page 1 Accessing the CLI Through the Console Port, page 1 Entering the Initial Configuration Information,
More information16/24-Port 10/100/1000T 802.3at PoE + 2-Port 100/1000X SFP Managed Switch GS P2S GS P2S. Quick Installation Guide
16/24-Port 10/100/1000T 802.3at PoE + 2-Port 100/1000X SFP Managed Switch GS-4210-16P2S GS-4210-24P2S Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4 3. Terminal
More informationAll Rights Reserved. Rev. 1.0, 2003
All Rights Reserved The use, disclosure, modification, transfer or transmittal of this work for any purpose, in any form, or by any means, without the written permission from Net2Phone is strictly forbidden.
More informationNCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL
NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT
More informationQuick Start Guide. Remote Console Manager Quick Start Guide
LES1202A-R2 LES1203A-M-R2 LES1204A-R2 Remote Console Manager Quick Start Guide Quick Start Guide This quick start guide helps you through installation, configuration, and local operation. For more details,
More informationThe Applications and Gaming Tab - Port Range Forward
The Applications and Gaming Tab - Port Range Forward The Applications and Gaming Tab allows you to set up public services on your network, such as web servers, ftp servers, e-mail servers, or other specialized
More informationConfiguring the Switch with the CLI-Based Setup Program
Configuring the Switch with the CLI-Based Setup Program This appendix contains these topics: Accessing the CLI Through Express Setup, page 1 Accessing the CLI Through the Console Port, page 1 Entering
More informationVERTICAL HORIZON VH-2402S FAST ETHERNET SWITCH MANAGEMENT GUIDE
VERTICAL HORIZON VH-2402S FAST ETHERNET SWITCH MANAGEMENT GUIDE 9033645-01 Notice Only qualified personnel should perform installation procedures. NOTICE Enterasys Networks reserves the right to make
More informationQuick Start Guide. Remote Console Manager
LES1202A LES1203A-11G LES1203A-M LES1204A-R2 Remote Console Manager Quick Start Guide This Quick Start Guide helps you through installation, configuration, and local operation. For more details, refer
More information24-Port Gigabit with 4 Optional 10G Slots. Layer 3 Managed Stackable Switch XGS Quick Installation Guide
24-Port Gigabit with 4 Optional 10G Slots Layer 3 Managed Stackable Switch XGS3-24040 Quick Installation Guide Table of Contents 1. Package Content... 3 2. Switch Management... 4 3. Requirements... 5 4.
More informationSetting Up Your Cisco Unified Videoconferencing 3515 MCU
CHAPTER 2 Setting Up Your Cisco Unified Videoconferencing 3515 MCU This section describes the following topics: Physical Description, page 2-1 Preparing for Installation, page 2-2 Verifying the Package
More informationManaging Software. Upgrading the Controller Software. Considerations for Upgrading Controller Software
Upgrading the Controller Software, on page 1 Considerations for Upgrading Controller Software, on page 1 Upgrading Controller Software (GUI), on page 2 Upgrading Controller Software (CLI), on page 5 Predownloading
More informationNetwork Management Card. User Manual
User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1
More informationASL Holdings Ltd. User Guide for the: - DELTA PLUS LAN modem. Provisional Ver1.8
Provisional Ver1.8 ASL Holdings Ltd User Guide for the: - DELTA PLUS LAN modem ASL Holdings Ltd,The Oaks, Spring Hill Office Park, Spring Hill Farm, Harborough Road, Pitsford, Northampton, NN6 9AA Tel:+44
More information6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Ethernet Option W8, W18 March 2012, Rev. E Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without
More informationSmartView EMS. Central EMS. SmartConfig. Fault, Configuration, Accounting, Performance & Security Management (FCAPS)
SmartView EMS TM Fault, Configuration, Accounting, Performance & Security Management (FCAPS) Central EMS Expand EMS platform up to 50 SmartViewTM and 25,000 devices management SmartConfig TM Tool for quick
More informationProduct Family: Networking Hardware Number: AN-NH-012
APPLICATION NOTE THIS INFORMATION PROVIDED BY AUTOMATIONDIRECT.COM TECHNICAL SUPPORT These documents are provided by our technical support department to assist others. We do not guarantee that the data
More informationinstallation manual SALES AND ADMINISTRATION (toll free)
installation manual SALES AND ADMINISTRATION 800.637.2645 (toll free) 217.442.0611 sales@timeomatic.com TECHNICAL SUPPORT 866.637.2645 (toll free) service@timeomatic.com www.watchfiresigns.com Quick Start-Up
More informationNetwork Management Card. User Manual
User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1
More informationQuick Start Guide LES1308A, LES1316A LES1332A, LES1348A. Securely manage data center and network equipment from anywhere in the world.
LES1308A, LES1316A LES1332A, LES1348A 8-/16-/32-/48-Port Advanced Console Server with GSM Modem QS Guide Quick Start Guide Securely manage data center and network equipment from anywhere in the world.
More informationAP-ENBD User Manual V0.2
AP-ENBD User Manual V0.2 2015/12 Catolog Catolog... 2 1 Introduction... 1 1.1 Communication Structure... 1 1.2 Internal Principle... 2 2 Installation... 2 2.1 Connect to the Same Router (or Switch )...
More informationDMC SNMP Module for Chassis-Based Media Converter Manual. Rev. 01 (JUN. 2002) 1907MCB RECYCLABLE
DMC-1002 SNMP Module for Chassis-Based Media Converter Manual Rev. 01 (JUN. 2002) 1907MCB10016000 RECYCLABLE TABLE OF CONTENTS ABOUT THIS GUIDE... 2 FEATURES...2 UNPACKING...2 CONFIGURING THE SYSTEM...
More informationRDU-SIC Card User Manual
RDU-SIC Card User Manual Version V1.3 Revision date November 16, 2011 BOM 31011798 Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office
More informationIndustrial Serial Device Server
1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device
More informationAdvantech AE Technical Share Document
Advantech AE Technical Share Document Date 02/02/2016 Release Note Internal External Category FAQ SOP Related OS Windows OS Abstract How to set up device server/modbus GW configuration in Web-Based interface
More informationConfiguring Host Router and Cisco Analog Video Gateway Module Interfaces
Configuring Host Router and Cisco Analog Video Gateway Module Interfaces Last Updated: August 17, 2009 To configure the Cisco Analog Video Gateway network module after it is installed in your host Cisco
More informationGrandstream GXV GXV3611LL, 3601HD Admin Guide
Grandstream GXV GXV3611LL, 3601HD Admin Guide Schmooze Com Inc. Chapters How to Find the IP Address How to Find the MAC Address How to Set the Configuration Server How to Restore Factory Default How to
More informationRevision: 2.0. User's Manual
Revision: 2.0 User's Manual Revision Number:2.0 Table of Contents 1. Overview... 1 2. Features... 1 3. Packaging... 1 4. Appearance... 2 5. Hardware Installation... 3 6. Management... 4 7. Default values...
More informationLab 3: Basic Device Configuration
Lab 3: Basic Device Configuration University of Jordan Faculty of Engineering & Technology Computer Engineering Department Computer Networks Laboratory 907528 2 Lab 3: Basic Device Configuration **Given
More informationManagement Security Switch SGSD-1022 / SGSD-1022P SGSW-2840 / SGSW-2840P. Quick Installation Guide
Management Security Switch SGSD-1022 / SGSD-1022P SGSW-2840 / SGSW-2840P Quick Installation Guide Table of Contents 1. Package Content... 3 2. Requirements... 4 3. Terminal Setup... 5 4. Logon to the Console...
More informationSTM-1 Mux SONET/SDH Multiplexer User Manual
STM-1 Mux SONET/SDH Multiplexer User Manual [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type the abstract of the document here. The
More informationMonitor and Manage your Power System with Ease.
Model 2000 Recorder Functional IRIG-B Functional Records Stored Test Mode Alarm Model 2000 Recorder Functional IRIG-B Functional Records Stored Test Mode Alarm People with Passion Accessing Multiple Remote
More informationQuick Start Guide. 8-Port Value-Line Console Server QS Guide LES1508A
LES1508A 8-Port Value-Line Console Server QS Guide Quick Start Guide This Quick Start Guide helps you through installation, configuration, and local operation. For more details, refer to the user manual
More information1. PRODUCTS AFFECTED OVERVIEW REASON FOR UPGRADE EVERTZ SERVICE CONTACT INFORMATION FIRMWARE UPGRADE...
1. PRODUCTS AFFECTED... 2 2. OVERVIEW... 2 3. REASON FOR UPGRADE... 2 3.1. FEATURE ENHANCEMENTS AVAILABLE IN RELEASE 2.6 BUILD 6... 3 4. EVERTZ SERVICE CONTACT INFORMATION... 3 5. FIRMWARE UPGRADE... 3
More informationAXIS T85 PoE+ Network Switch Series. AXIS T8524 PoE+ Network Switch. AXIS T8516 PoE+ Network Switch. User Manual
AXIS T8508 PoE+ Network Switch AXIS T8516 PoE+ Network Switch AXIS T8524 PoE+ Network Switch User Manual Table of Contents About this document........................................ 3 Solution overview...........................................
More informationConfiguring the Switch with the CLI Setup Program
APPENDIXC Configuring the Switch with the CLI Setup Program This appendix provides a command-line interface (CLI) setup procedure for a standalone switch. To set up the switch by using Express Setup, see
More informationQUICK START GUIDE. STEP X - Name of Step LES1708A, LES1716A, LES1732A, LES1748A CONSOLE SERVERS
STEP X - Name of Step QUICK START GUIDE LES1708A, LES1716A, LES1732A, LES1748A CONSOLE SERVERS 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM STEP 1 - Check Kit Contents PACKAGE INCLUDES
More informationChapter 11. Configuring and Testing Your Network
Chapter 11 Configuring and Testing Your Network CCNA1-1 Chapter 11 Note for Instructors These presentations are the result of a collaboration among the instructors at St. Clair College in Windsor, Ontario.
More informationL2+ Managed Gigabit Switch WGSW series
L2+ Managed Gigabit Switch WGSW-24040 series Quick Installation Guide Table of Contents 1 Package Contents... 3 2. Requirements... 4 3. Terminal Setup... 5 3.1 Logon to Console... 6 3.2 Configuring IP
More informationWhen an event such as a power failure or a low battery condition occurs,.netpower will notify users via the following ways:
Introduction The.NETpower Card/Box is primarily used to provide a network management function for the UPS. After plugging it into the UPS, you can manage the UPS remotely via an SNMP NMS (Network Management
More informationSwitched Rack Power Distribution Unit
Switched Rack Power Distribution Unit AS-216-520-30A-L530 Installation and Quick Start Contents Product Description and Inventory...................... 1 AS-216-520-30A-L530....................... 1 Additional
More informationL2/L4 Managed Gigabit Ethernet Switch GS-4210 Ultra PoE Series
L2/L4 Managed Gigabit Ethernet Switch GS-4210 Ultra PoE Series Quick Installation Guide Table of Contents 1. Introduction... 3 2. Package Contents... 4 3. Requirements... 5 4. Terminal Setup... 6 5. Logon
More informationBefore you start the lab exercises see the lab administrator or EEE3080F tutor to get assigned to your routers.
EEE00F Lab Basics of the Network Lab Student Lab Manual Before you start the lab exercises see the lab administrator or EEE00F tutor to get assigned to your routers. Contents. Resources used in the labs...
More information10/100Mbps 2Port USB2.0 MFP Server
10/100Mbps 2Port USB2.0 MFP Server Mini-MFP Quick Installation Guide English Ver.1.0 Quick Installation Guide CONTENTS STEP 1 / Mbps Port USB MFP Server Introduction Package Contents OS Requirements Physical
More informationPreface. Managed Media Converter Chassis System
Preface The Managed Media Converter Chassis System supports the Media Converter Chassis to monitor the each Media Converter ( CO ) or Chassis Manager status and to configure advanced function of the Managed
More informationAtop ABLELink Ethernet-Serial Server GW21E
Atop ABLELink Ethernet-Serial Server GW21E User Manual Version 2.3 Updated on 2004/08/18 Tel: 886-3-5508137 Fax: 886-3-5508131 www.atop.com.tw IMPORTANT ANNOUNCEMENT The information contained in this document
More informationLevelOne FBR User s Manual. 1W, 4L 10/100 Mbps ADSL Router. Ver
LevelOne FBR-1416 1W, 4L 10/100 Mbps ADSL Router User s Manual Ver 1.00-0510 Table of Contents CHAPTER 1 INTRODUCTION... 1 FBR-1416 Features... 1 Package Contents... 3 Physical Details... 3 CHAPTER 2
More informationCommunication adapter RS485/422 over the Ethernet ELO E222. User manual
Communication adapter RS485/422 over the Ethernet ELO E222 User manual Table Of Content: 1.0 Introduction... 3 1.1 Application... 3 2.0 How does it works?... 4 3.0 Installation... 4 3.1 Ethernet connection...
More informationUsing the Offline Diagnostic Monitor Menu
APPENDIX B Using the Offline Diagnostic Monitor Menu During the boot process, you can access the Offline Diagnostic Monitor (Offline DM) Main menu. The Offline DM Main menu allows you to perform the following
More informationEthernet-232 User s Manual
Ethernet-232 User s Manual Design Gateway Co., Ltd. Rev 1.0 (PD0503-6-00-01E) *** Please read this manual carefully before using Ethernet-232 *** Revision History Revision Date Detail of change 1.0 28
More information