6 Buck Boost Transformers

Size: px
Start display at page:

Download "6 Buck Boost Transformers"

Transcription

1 6 uck oost Transformers uck-oost transformers are small, single phase, dry type distribution transformers designed and shipped as insulating/isolating transformers. They have a dual voltage primary and a dual voltage secondary. These transformers can be connected for a wide range of voltage combinations. The most common use is to buck (lower) or boost (raise) the supply voltage a small amount, usually 5 to 27%. uck-boost transformers are in compliance with NEC rticle 210.9, Exception 1 when field connected as an autotransformer. The major advantages of uck-boost transformers are their low cost, compact size and light weight. They are also more efficient and cost less than equivalent isolation transformers. When connected as an autotransformer, they can handle loads up to 20 times the nameplate rating. buck-boost transformer is the ideal solution for changing line voltage by small amounts. When a buck-boost has the primary and secondary windings connected, per recommended instructions, it becomes an autotransformer. Now, only the secondary windings are transforming voltage and current. The majority of the kv load passes directly from the supply to the load. This is the reason buck-boost transformers can supply a load with a much larger kv rating than the nameplate indicates. Low voltage lighting control applications SolaHD buck-boost transformers are designed to supply power to low voltage lighting circuits, control panels or other systems requiring 12, 16, 24, 32, or 48 Volts. When connected as an insulating transformer (by following the wiring diagram located after the specification tables on the inside of the transformer case), the transformer s capacity matches the nameplate kv rating. SolaHD buck-boost transformers are also suited for low voltage landscape lighting. They are UL Listed for outdoor service and their compact size makes them the perfect solution for providing power to accent lighting applications. Electrical diagrams are shown at the end of this section. Use dimmers on the output of the transformer that are designed and rated for use with magnetic loads. We strongly recommend contacting the dimmer manufacturer for advice on your specific lighting application. Certifications and Compliances Listed - UL CS C22.2 No. 66 ccessories Surge Protective Devices ctive Tracking ilters Selection Steps 1. Line easure the supply voltage with a voltmeter. 2. equired for the Load Check the load equipment to determine the voltage requirement. 3. kv or mpere ating of the Load ind either the load kv or the load amperage requirements. This information is listed on the nameplate of the load equipment. E requency Either 50 or 60 Hz. The frequency of the transformer must match the frequency of the load. 5. Number of Phases Single or three phase line and load must match. ( transformer cannot convert single to three phase.) common application is to make a single phase connection from a three phase supply by using one phase of the three phase supply circuit. e careful not to overload that phase of the three phase supply. or buck-boost applications the supply must provide load kv not just the nameplate rating of the buck-boost. efer to the Selection Tables on the following pages. 230

2 uck oost Transformers 6 Three phase, buck-boost applications require two or three transformers. Check the equired column of the Three Phase Selection Tables for the exact quantity. using uck-oost Transformers or determining the correct size of breaker or fuse for a given range of input or output ampere ratings, refer to Section 450.4, of the National Electric Code (NEC). Where an overcurrent protection device is required, the electrical connections and selection tables will reference appropriately. Using the Selection Tables 1. Determine if you are trying to oost (raise) or uck (lower) your voltage. Select an input/output voltage combination that comes closest to matching your application from the appropriate single or three phase charts on the following pages. 2. ove across your selected input/output voltage row to the amperage or kv rating closest to, but greater than the rating required by your load. 3. eading the top of the column will give you the catalog number of the exact buck-boost transformer you need. See the Specification Tables on the next page. 4. Connect the transformers according to the diagram indicated. See the Electrical s section at the end of this section. diagrams are packed with each transformer. Overcurrent devices OC-1a and OC-1b are shown correctly installed in accordance with NEC Locating an overcurrent device in series with the shunt winding anywhere between and is not permitted. The shunt winding is the winding common to both the input and the output circuits. 231

3 6 uck oost Transformers Specification Tables Group x 240 Volt Primary, 12/24 Volt Secondary KV aximum Secondary mperage 12 V 24 V Height in (mm) Width in (mm) Non-Encapsulated - 50/60 Hz, Single Phase Depth in (mm) pprox. Ship Weight lbs (kg) 0.05 HS (152.4) 4.00 (101.6) 3.00 (76.2) 2.0 (0.91) HS (152.4) 4.00 (101.6) 3.00 (76.2) 4.0 (1.82) HS (190.5) 4.00 (101.6) 4.00 (101.6) 5.0 (2.27) HS (190.5) 4.00 (101.6) 4.00 (101.6) 8.0 (3.64) 2 1 Encapsulated - 60 Hz, Single Phase 0.5 HS (254.0) 6.00 (152.4) 5.00 (127.0) 22.0 (10.00) HS (254.0) 6.00 (152.4) 5.00 (127.0) 27.0 (12.27) HS (254.0) 6.00 (152.4) 5.00 (127.0) 28.0 (12.73) HS (304.8) (254.0) 7.00 (177.8) 38.0 (17.27) HS (304.8) (254.0) 7.00 (177.8) 45.0 (20.45) HS (304.8) (254.0) 7.00 (177.8) 55.0 (25.00) HS (431.8) (355.6) 9.00 (228.6) (45.45) HS (431.8) (355.6) 9.00 (228.6) (61.36) 4 1 Design Style Elec Conn Group x 240 Volt Primary, 16/32 Volt Secondary KV aximum Secondary mperage 16 V 32 V Height in (mm) Width in (mm) Non-Encapsulated - 50/60 Hz, Single Phase Depth in (mm) pprox. Ship Weight lbs (kg) 0.15 HS (203.2) 4.00 (101.6) 4.00 (101.6) 6.0 (2.73) HS (203.2) 4.00 (101.6) 4.00 (101.6) 8.0 (3.64) 2 2 Encapsulated - 60 Hz, Single Phase 0.5 HS (254.0) 6.00 (152.4) 5.00 (127.0) 22.0 (10.00) HS (254.0) 6.00 (152.4) 5.00 (127.0) 27.0 (12.27) HS (254.0) 6.00 (152.4) 5.00 (127.0) 28.0 (12.73) HS (304.8) (254.0) 7.00 (177.8) 38.0 (17.27) HS (304.8) (254.0) 7.00 (177.8) 45.0 (20.45) HS (304.8) (254.0) 7.00 (177.8) 55.0 (25.00) HS (431.8) (355.6) 9.00 (228.6) (45.45) HS (431.8) (355.6) 9.00 (228.6) (61.36) 4 2 Design Style Elec Conn Note: Weights and dimensions may change and should not be used for construction purposes. 232

4 uck oost Transformers 6 Specification Tables continued Group x 480 Volt Primary, 24/48 Volt Secondary KV Catalog Number aximum Secondary mperage 24 V 48 V Height in (mm) Width in (mm) Non-Encapsulated - 50/60 Hz, Single Phase Depth in (mm) pprox. Ship Weight lbs (kg) 0.15 HS (203.2) 4.00 (101.6) 3.00 (76.2) 5.0 (2.27) HS (203.2) 4.00 (101.6) 3.00 (76.2) 8.0 (3.64) 2 3 Encapsulated - 60 Hz, Single Phase 0.5 HS (203.2) 6.00 (152.4) 5.00 (127.0) 22.0 (10.00) HS (254.0) 6.00 (152.4) 5.00 (127.0) 27.0 (12.27) HS (254.0) 6.00 (152.4) 5.00 (127.0) 28.0 (12.73) HS (304.8) (254.0) 7.00 (177.8) 38.0 (17.27) HS (304.8) (254.0) 7.00 (177.8) 45.0 (20.45) HS (304.8) (254.0) 7.00 (177.8) 55.0 (25.00) HS (431.8) (355.6) 9.00 (228.6) (45.45) HS (431.8) (355.6) 9.00 (228.6) (61.36) 4 3 Note: Weights and dimensions may change and should not be used for construction purposes. Design Style Elec Conn Electrical s for Low pplications = Earth Ground Volt Primary, 12/24 Volt Secondary Taps: None Volt Primary, 16/32 Volt Secondary Taps: None Volt Primary, 24/48 Volt Secondary Taps: None Primary Interconnect Connect Lines To 240 to & 120 to to & Secondary Interconnect Connect Lines To 24 to & to to to to HS19 and S19 Series -- & Primary Interconnect Connect Lines To 240 to & 120 to to & Secondary Interconnect Connect Lines To 32 to & to to to to HS20 and S20 Series -- & Primary Interconnect Connect Lines To 480 to & 240 to to & Secondary Interconnect Connect Lines To 48 to & to to to to HS22 and S22 Series -- & 233

5 6 uck oost Transformers Design Styles Custom Design Styles Style 2 - Non-Encapsulated Style 5 - Encapsulated vailable for all encapsulated kv sizes (or Type 4, 12 and 4) Style 3 - Encapsulated Style 4 - Encapsulated 234

6 uck oost Transformers 6 Selection Tables: Single Phase Table 1: Using Group 1 (120 x 240 V Primary, 12/24 V Secondary) Transformers eq d D C D1 218 ** D C1 132 ** ** D2 252 ** C2 264 ** D2 pplication HS1950 HS19100 HS19150 HS19250 HS19500 HS19750 HS191 OOSTING kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size UCKING kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size * or alternate electrical connection diagrams, refer to the section immediately following the selection tables. ** Shaded items are 60 Hz only (ll other ratings shown are 50/60 Hz). 235

7 6 uck oost Transformers Selection Tables: Single Phase Table 1: Using Group 1 (120 x 240 V Primary, 12/24 V Secondary) Transformers eq d D C D1 218 ** D C1 132 ** ** D2 252 ** C2 264 ** D2 pplication HS191.5 HS192 HS193 HS195 HS197.5 OOSTING kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size UCKING kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size * or alternate electrical connection diagrams, refer to the section immediately following the selection tables. ** Shaded items are 60 Hz only (ll other ratings shown are 50/60 Hz). 236

8 uck oost Transformers 6 Selection Tables: Single Phase Table 2: Using Group 2 (120 x 240 V Primary, 16/32 V Secondary) Transformers eq d D C D C1 240 ** D1 136 ** ** D2 256 ** C2 272 ** D2 pplication HS20150 HS20250 HS20500 HS20750 HS201 OOSTING kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size UCKING kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size * or alternate electrical connection diagrams, refer to the section immediately following the selection tables. ** Shaded items are 60 Hz only (ll other ratings shown are 50/60 Hz). 237

9 6 uck oost Transformers Selection Tables: Single Phase Table 2: Using Group 2 (120 x 240 V Primary, 16/32 V Secondary) Transformers eq d D C D C1 240 ** D1 136 ** ** D2 256 ** C2 272 ** D2 pplication HS201.5 HS202 HS203 HS205 HS207.5 OOSTING kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size UCKING kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size * or alternate electrical connection diagrams, refer to the section immediately following the selection tables. ** Shaded items are 60 Hz only (ll other ratings shown are 50/60 Hz). 238

10 uck oost Transformers 6 Selection Tables: Single Phase Table 3: Using Group 3 (240 x 480 V Primary, 24/48 V Secondary) Transformers eq d ** D C D D1 458 ** C1 277 ** C2 418 ** D2 504 ** C2 528 ** D2 pplication HS22150 HS22250 HS22500 HS22750 HS221 OOSTING kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size UCKING kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size * or alternate electrical connection diagrams, refer to the section immediately following the selection tables. ** Shaded items are 60 Hz only (ll other ratings shown are 50/60 Hz). 239

11 6 uck oost Transformers Selection Tables: Single Phase Table 3: Using Group 3 (240 x 480 V Primary, 24/48 V Secondary) Transformers eq d ** D C D D1 458 ** C1 277 ** C2 418 * D2 504 ** C2 528 ** D2 pplication HS221.5 HS222 HS223 HS225 HS227.5 OOSTING kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size UCKING kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size * or alternate electrical connection diagrams, refer to the section immediately following the selection tables. ** Shaded items are 60 Hz only (ll other ratings shown are 50/60 Hz). 240

12 uck oost Transformers 6 Selection Tables: Three Phase Table 4: Using Group 1 (120 x 240 V Primary, 12/24 V Secondary) Transformers eq d E J1 228 ** E L E ** E2 264 ** pplication HS1950 HS19100 HS19150 HS19250 HS19500 HS19750 HS191 OOSTING kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size UCKING kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size * or alternate electrical connection diagrams, refer to the section immediately following the selection tables. ** Shaded items are 60 Hz only (ll other ratings shown are 50/60 Hz). 241

13 6 uck oost Transformers Selection Tables: Three Phase Table 4: Using Group 1 (120 x 240 V Primary, 12/24 V Secondary) Transformers eq'd pplication HS191.5 HS192 HS193 HS195 HS E J1 228 ** E L E ** E2 264 ** OOSTING kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size UCKING kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size * or alternate electrical connection diagrams, refer to the section immediately following the selection tables. ** Shaded items are 60 Hz only (ll other ratings shown are 50/60 Hz). 242

14 uck oost Transformers 6 Selection Tables: Three Phase Table 5: Using Group 2 (120 x 240 V Primary, 16/32 V Secondary) Transformers eq'd pplication HS20150 HS20250 HS20500 HS20750 HS E J E L E ** E2 272 ** OOSTING kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size UCKING kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size * or alternate electrical connection diagrams, refer to the section immediately following the selection tables. ** Shaded items are 60 Hz only (ll other ratings shown are 50/60 Hz). 243

15 6 uck oost Transformers Selection Tables: Three Phase Table 5: Using Group 2 (120 x 240 V Primary, 16/32 V Secondary) Transformers eq'd pplication HS201.5 HS202 HS203 HS205 HS E J E L E ** E2 272 ** OOSTING kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size UCKING kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size * or alternate electrical connection diagrams, refer to the section immediately following the selection tables. ** Shaded items are 60 Hz only (ll other ratings shown are 50/60 Hz). 244

16 uck oost Transformers 6 Selection Tables: Three Phase Table 6: Using Group 3 (240 x 480 V Primary, 24/48 V Secondary) Transformers eq'd G G E K K E G K K2 504 ** E2 528 ** pplication HS22150 HS22250 HS22500 HS22750 HS221 OOSTING kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size UCKING kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size * or alternate electrical connection diagrams, refer to the section immediately following the selection tables. ** Shaded items are 60 Hz only (ll other ratings shown are 50/60 Hz). 245

17 6 uck oost Transformers Selection Tables: Three Phase Table 6: Using Group 3 (240 x 480 V Primary, 24/48 V Secondary) Transformers eq'd G G E K K E G K K2 504 ** E2 528 ** pplication HS221.5 HS222 HS223 HS225 HS227.5 OOSTING kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size UCKING kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size kv Load mps use Size * or alternate electrical connection diagrams, refer to the section immediately following the selection tables. ** Shaded items are 60 Hz only (ll other ratings shown are 50/60 Hz). 246

18 uck oost Transformers 6 lternate Electrical s for uck-oost pplications Diagram 1 oosting Diagram 1 oosting Diagram C1 oosting Diagram 2 ucking Diagram 2 ucking Diagram C2 ucking The O symbol shown on these connection diagrams indicates where fuses or breakers should be field installed for line to neutral applications. or line to line applications, fuses or breakers should be installed on both lines. pplication Note: On all auto-wye connections, the source neutral must be present and connected to the transformer bank. If source neutral is not present, do not use an auto-wye connection. 247

19 6 uck oost Transformers lternate Electrical s for uck-oost pplications OPEN DELT OPEN DELT Diagram D1 oosting Diagram E1 oosting Diagram 1 oosting OPEN DELT OPEN DELT Diagram D2 ucking Diagram E2 ucking Diagram 2 ucking 248

20 uck oost Transformers 6 lternate Electrical s for uck-oost pplications OPEN DELT OPEN DELT UTO-WYE CONNECTION C Diagram G1 oosting Diagram oosting Diagram J1 oosting OPEN DELT OPEN DELT UTO-WYE CONNECTION C Diagram G2 ucking Diagram ucking Diagram J2 ucking 249

21 6 uck oost Transformers lternate Electrical s for uck-oost pplications UTO-WYE CONNECTION C UTO-WYE CONNECTION C UTO-WYE CONNECTION C Diagram K1 oosting Diagram L1 oosting Diagram 1 oosting UTO-WYE CONNECTION C UTO-WYE CONNECTION C UTO-WYE CONNECTION C Diagram K2 ucking Diagram L2 ucking Diagram 2 ucking 250

22 uck oost Transformers 6 pplication Note pplication Limitations with uck-oost Transformers 1. uck-oost transformer cannot be used to develop a three phase, four wire wye circuit from a three phase, three wire delta circuit. delta to wye connection does not supply enough current carrying capability to provide for unbalanced currents flowing in the neutral wire of the four wire circuit. The neutral created is not stable and under load will not deliver desired line to neutral voltages. This connection would also be in violation of the National Electric Code, rticle uck-oost transformers cannot be used in a closed delta connection. closed delta requires more kv capacity than a wye or an open delta connection, plus phase shifting comes into play on the output side. 3. uck-oost transformers should not be used to correct for voltage drop on a long circuit run where the load fluctuates. drop varies with the load and buck-boost transformers are connected for a specific voltage change. If a buck-boost transformer was used to correct voltage drop during peak loading conditions, high voltages may result under light load conditions. This could be equally detrimental to the load and possibly pose safety hazards. 4. uck-oost transformers cannot be used to create a 240/120 Volt, single phase service from a 208Y/120 Volt three phase supply. Two problems that would occur:. Two neutrals would exist on the same circuit. Since neutrals must be grounded according to the National Electric Code, a short circuit would be created.. Unbalanced line to output neutral voltages would be created; one line would read 120 Volts, the other 130+ Volts. What is a uck-oost transformer and why is it used? Isolation transformers have separate primary and secondary windings, electrically insulated and isolated from one another. With a relatively high voltage primary (typically 120, 240 or 480 Volts) and a relatively low voltage secondary (typically 12, 16, 24, 32 or 48 Volts), buck-boost transformers are designed to be field connected as autotransformers. These are transformers with one continuous winding, a portion of which is jointly shared between the input and the output. No electrical isolation is present in an autotransformer. uck-oost transformers have two major uses: 1. When field connected as an autotransformer, they can be used to uck (lower) or oost (raise) available line voltage in the range of 5 to 27% and at a kv rating many times that listed on the transformer nameplate. 2. When left as an isolation transformer, they can be used to supply power to low voltage circuits at the nameplate rating listed. The importance of altering available line voltage. Electrical equipment is designed to operate at maximum efficiency at a specific standard supply voltage. Your voltage may not be at the standard supply voltage level. Causes can be proximity to a large utility transformer, losses in the line voltage due to loads on that circuit, or a difference between the standard supply voltage available and the standard supply voltage needed to run the equipment. Normally the problem is having low voltage available. Low voltage on a circuit, even as little as 5% lower can cause a decrease in incandescent light output, and a decrease in resistive heat output. With motors low voltage can cause a decrease in motor torque, an increase in motor amperage requirements, an increase in motor temperature and decrease in motor life expectancy. 251

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC The PCI Series Phase Angle Fired SCR Power Controls 25-1200 AMPS 120-600 VAC Precise power control for complex SCR applications. ROBICON 1996 Distributed Worldwide by www.mcgoff-bethune.com Applications

More information

Single-Phase Encapsulated

Single-Phase Encapsulated Single-Phase Encapsulated 7 50 VA to 25 kva Applications n For general loads, indoors or out, including lighting, industrial and commercial applications n Units may be banked for 3-Phase operations n For

More information

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death. Installation/Operation Manual TABLE OF CONTENTS Page UNPACKING AND INSTALLATION Unpacking and Preliminary Inspection...2, 3 Model Number...9 LOCATION CONSIDERATIONS Environment, Equipment Performance,

More information

Standard SureVolt Power Conditioner / Voltage Regulator

Standard SureVolt Power Conditioner / Voltage Regulator Utility Systems Technologies, Inc. P.O. Box 110 Latham, NY 12110 Standard SureVolt Power Conditioner / Voltage Regulator Introduction The SureVolt electronic voltage regulator / power conditioner provides

More information

Industrial Control. 50 to 5,000 VA. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

Industrial Control. 50 to 5,000 VA. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits. Industrial Control 6 50 to 5,000 VA Applications n For commercial and industrial control applications including; control panels, conveyor systems, machine tool equipment, pump systems, and commercial air

More information

SLI 15 INVERTER SERIES, 1500 W

SLI 15 INVERTER SERIES, 1500 W SLI 15 INVERTER SERIES, 1500 W FEATURES DESCRIPTION New, compact design: 1U height x 19" width x 14.94" depth; 19" rack-mountable High efficiency: up to 93% True sine wave output Parallelable output with

More information

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters Applications Telecom IT Industrial Safety in compliance with IEC60950:1999, 3 rd edition; EN60950:2000; UL60950, 3 rd edition; CSA Standard C22.2 No.60950-00, 3 rd edition Features New, compact design:

More information

Application Techniques CENTERLINE 2100 Motor Control Centers

Application Techniques CENTERLINE 2100 Motor Control Centers POWER SYSTEM CONSIDERATIONS FOR PRODUCT SELECTION Application Techniques CENTERLINE 2100 Motor Control Centers Power System Considerations for Product Selection i Power System Considerations for Product

More information

2 Check that Public Safety has been considered (e.g. cabinet secured and locked, trip hazards removed where applicable).

2 Check that Public Safety has been considered (e.g. cabinet secured and locked, trip hazards removed where applicable). NOTE: SAFETY: Tests must be carried out after the installation, alteration or repair and before putting back to service. At all times maintain suitable clearance to all other electrical equipment and verify

More information

General Purpose Transformers 6

General Purpose Transformers 6 General Purpose Transformers 6 Description Dry-type transformers (en cap su lat ed, ventilated or non-ventilated), 600 Volt Class, isolation type, single and three phase, through 500. Indoor and outdoor

More information

VersaPoint I/O Module

VersaPoint I/O Module Output 24VDC Positive Logic 0.5A 14 Points Module is used to output 24VDC digital signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature 48.8mm

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

Industrial Control. 50 to 5,000 VA. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

Industrial Control. 50 to 5,000 VA. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits. Industrial Control 6 50 to 5,000 VA Applications n For commercial and industrial control applications including; control panels, conveyor systems, machine tool equipment, pump systems, and commercial air

More information

15-80 ka surge protection Hz line frequency <.5 ns response time Available in units noted from 15-1,200 Amps

15-80 ka surge protection Hz line frequency <.5 ns response time Available in units noted from 15-1,200 Amps Series Filters with Transient Voltage Surge Suppression Islatrol Series Two stage, high-frequency noise filter and high-energy current diverter available from 5 mp single phase to 1200 mp three phase.

More information

FCD Series. UL Recognized. FCD Series. Specifications. Ordering Information 150 FCD 10 BS -95. Electrical Schematics 6FCD10: Corcom Product Guide

FCD Series. UL Recognized. FCD Series. Specifications. Ordering Information 150 FCD 10 BS -95. Electrical Schematics 6FCD10: Corcom Product Guide atalog: 161 Issue Date: 06.11 3-phase Delta xternal Power Line ilter for requency onverters UL Recognized 6D Suitable to meet the latest M standards Insulated safety terminals Suitable for M troubleshooting

More information

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) Instruction Bulletin 8222-0513B Retain for future use. SPIKESHIELD Wired-In Branch Panels 8222-0513B 05/2012 Table of Contents Precautions...

More information

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2 Supersedes 6/2015 Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2 XXCFXXX10-DIN Contents Description Page 1.0 Setup...2 1.1 Before Installation...2 1.2 Installation...3 For AC Applications...3

More information

SAMSUNG ELECTRO-MECHANICS CO., LTD

SAMSUNG ELECTRO-MECHANICS CO., LTD Model Name : Features : ㅡ Suitable for LED lighting application ㅡ UL8750, UL1310 Class 2 ㅡ For use in Dry and Damp Location ㅡ Full-protection provided: OCP/OLP/OTP/SCP ㅡ Non potting product Electrical

More information

Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02

Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02 Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02 User Manual 1.1 Overview Telect s 80A, -48 Vdc Low-Voltage Disconnect (LVD) panel is a rack-mounted component with coil-operated contactors. These

More information

Standards Update Notice (SUN) Issued: April 25, 2017

Standards Update Notice (SUN) Issued: April 25, 2017 Standard Information Standard Number: UL 1951 Standard Name: Electric Plumbing Accessories Standard Edition and Issue Date: 2 nd Edition Dated July 22, 2011 Date of Revision: February 21, 2017 Date of

More information

Electronic Motor Protection Relays Bulletin 193-E

Electronic Motor Protection Relays Bulletin 193-E Electronic otor Protection Relays Bulletin 93-E 93-EB also includes: Trip Class 0, or 0 selectable Ground Fault Protection Jam/Stall Protection Product Selection... -3 ccessories dd-on ccessories... -

More information

Hubbell Surge Protective DeviceS

Hubbell Surge Protective DeviceS Hubbell Surge Protective DeviceS Hubbell Modular Panel Products Surge Protective Devices (SPD) The Hubbell Modular Panel Product Surge Protective Devices (SPD) are designed to provide protection at the

More information

Medium Voltage Metal-Enclosed Power Capacitor Banks

Medium Voltage Metal-Enclosed Power Capacitor Banks 66 Carey Road Queensbury, NY 12804 Ph: (518) 792-4776 Fax: (518) 792-5767 www.nepsi.com sales@nepsi.com Medium Voltage Metal-Enclosed Power Capacitor Banks General Northeast Power System s (NEPSI's) medium

More information

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be

More information

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , COMPACT LED DRIVERS EasyLine SIMPLE FIX 186591, 186592, 186593, 186594, 186595, 186669 Typical Applications Built-in in or independent version for Shop lighting Downlights EasyLine with fixed output current

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

Level 2, 3 and 4 Interconnection Application for Certified, Inverter Based Generating Facilities Not Greater than 2MW

Level 2, 3 and 4 Interconnection Application for Certified, Inverter Based Generating Facilities Not Greater than 2MW Level 2, 3 and 4 Interconnection Application for Certified, Inverter Based Generating Facilities Not Greater than 2MW The Customer Generator applicant ("Applicant") hereby makes application to the T &

More information

COMPACT LED CONVERTERS 48 V

COMPACT LED CONVERTERS 48 V COMPACT LED CONVERTERS 48 V EasyLine 48 V 186691, 186692 Typical Applications Shop lighting for 48 V systems Furniture lighting EasyLine 48 V VERY COMPACT SHAPE VERY LOW RIPPLE CURRENT LONG SERVICE LIFETIME:

More information

PowerLogic power-monitoring units. EM1000 series power meter. Technical data sheet

PowerLogic power-monitoring units. EM1000 series power meter. Technical data sheet PowerLogic power-monitoring units power meter Technical data sheet Distributed By: MetersUSA www.metersusa.com Meters@MetersUSA.com 1 224 365 5935 Basic energy meters Functions and characteristics PB105460

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs. CurrentWatch Current Sensors Ground Fault Sensors with Solid-State or Mechanical Relay s 1 Contents Overview.................... 1 Model Selection, Switches...... 2 Model Selection, Accessories... 3 Wiring

More information

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158 Magnetic Circuit Protectors 53 Multi-Pole Circuit Protectors 54 APL/UPL, 205/295 Barriers 55 Configurations 56 Operating Characteristics 58 Delay Curves 59 Specifications 64 APL/UPL Decision Tables 70

More information

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards The 29, E-Frame circuit breaker combines power switching with accurate, reliable circuit protection 29/29/229 Magnetic Circuit Protectors 99 in a compact single or multipole 249 Power Selector Breaker

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

APL/UPL, 205/295 Series Magnetic Circuit Protectors

APL/UPL, 205/295 Series Magnetic Circuit Protectors APL/UPL, 205/295 APL/UPL, 205/295 Series Magnetic Circuit Protectors Introduction 68 Single & Multi-Pole 69 Barriers 7 Configurations 72 Operating Characteristics 74 Delay Curves 75 Specifications 80 Decision

More information

Supplement to Instruction Manual

Supplement to Instruction Manual Supplement to Instruction Manual Compact Inverter 0 V series: FRN0001 to 00C2S-2U 400 V series: FRN0002 to 0011C2S-4U Single-phase 0 V series: FRN0001 to 0012C2S-7U Thank you for purchasing our FRENIC-Mini

More information

COMPACT LED DRIVERS. ComfortLine Residential. ComfortLine RESIDENTIAL , , ,

COMPACT LED DRIVERS. ComfortLine Residential. ComfortLine RESIDENTIAL , , , COMPACT LED DRIVERS ComfortLine RESIDENTIAL 186679, 186680, 186681, 186682 Typical Applications Built-in in compact luminaires for Residential lighting Downlights ComfortLine Residential VERY COMPACT SHAPE

More information

Installation Manual. APEX Series. Silicon and MOV Panel Protection. APEX Series

Installation Manual. APEX Series. Silicon and MOV Panel Protection. APEX Series Installation Manual APEX Series Silicon and MOV Panel Protection APEX Series APEX Series Installation Guide 2 Table of Contents Mechanical Installation 3 Table One - Application Rating 3 Figure 1 - Mounting

More information

Surge Protective Devices. STV100K Series. Instruction Manual

Surge Protective Devices. STV100K Series. Instruction Manual Surge Protective Devices STV100K Series Instruction Manual Contents 1.0 Installation... 4 1.1 Environment... 4 1.2 Mounting... 4 1.3 Proper Connection of SPDs... 4 1.4 Mechanical Dimensions... 5 1.5 Voltage

More information

Surge Protective Devices. STV100K Series. Instruction Manual

Surge Protective Devices. STV100K Series. Instruction Manual Surge Protective Devices STV100K Series Instruction Manual Contents 1.0 Installation... 4 1.1 Environment... 4 1.2 Mounting... 4 1.3 Proper Connection of SPDs... 4 1.4 Mechanical Dimensions... 5 1.5 Voltage

More information

Surgelogic Surge Protective Device I-Line Plug-On Unit Series

Surgelogic Surge Protective Device I-Line Plug-On Unit Series Surgelogic Surge Protective Device I-Line Plug-On Unit Series Catalog 1310CT0201R5/07 2007 Class 1310 CONTENTS Description Page Product Description.................................................. 2 Application

More information

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm Characteristics cam voltmeter switch - 3L and 3L-N - 60-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

Section 4 Ground-Fault Protection Devices

Section 4 Ground-Fault Protection Devices Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that

More information

R-LB R-LX Series Installation, Operation & Maintenance Manual

R-LB R-LX Series Installation, Operation & Maintenance Manual Installation, Operation & Maintenance Manual WARNINGS Safety First Hazardous Voltage & Shock Hazard Only qualified licensed electricians should install or service SPDs Hazardous voltages exist within SPDs

More information

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System MODEL NUMBER: SVX120KL Highlights 120kVA / 120kW modular, scalable, 3-phase, Large-Frame tower

More information

SagFighter Active Voltage Conditioner / Sag Ride Through (SRT)

SagFighter Active Voltage Conditioner / Sag Ride Through (SRT) Utility Systems Technologies, Inc. P.O. Box 110 Latham, NY 12110 SagFighter Active Voltage Conditioner / Sag Ride Through (SRT) Overview The SagFighter is an industrial-grade, solid state, electronic voltage

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

OmniSmart 120V 330VA 225W UL Medical Grade Line-Interactive UPS, Tower, DB9 Serial

OmniSmart 120V 330VA 225W UL Medical Grade Line-Interactive UPS, Tower, DB9 Serial OmniSmart 120V 330VA 225W UL 60601-1 Medical Grade Line-Interactive UPS, Tower, DB9 Serial MODEL NUMBER: OMNISMART350HG Highlights 330VA line interactive tower UPS Maintains sine-wave 120V nominal output

More information

Understanding SCCR. THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing

Understanding SCCR. THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing Understanding SCCR What is SCCR? When it comes to industrial machinery, it s critical to ensure that electrical panels are designed and built with the proper SCCR to maintain the system, eliminate downtime

More information

LED Driver Linear / area dimming

LED Driver Linear / area dimming Driver LC 35W 7mA -1V UNV sl ADV ADVANCED series Product description Built-in constant current For dry and damp location Max. output power 35 W Up to 85 % efficiency Nominal life-time up to 5, h For luminaires

More information

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V Characteristics soft starter for asynchronous motor - ATS01-6 A - 460..480 V Price* : 152.00 GBP Main Range of product Altistart 01 Product or component type Product destination Product specific application

More information

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units. Model KEP Automatic Transfer Switches Service Entrance Rated Controller D Decision-Makerr MPAC 1500 Ratings Power Switching Device Molded case (MCCB) Insulated Case (ICCB) Current Voltage, Frequency 200

More information

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units. Model KEP Automatic Transfer Switches Service Entrance Rated Controller D Decision-Makerr MPAC 1500 Ratings Power Switching Device Current Voltage, Frequency Molded case (MCCB) Insulated Case (ICCB) 200

More information

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2 Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,

More information

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7 Uninterruptible Power Supply Product Specifications Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,

More information

Metering Devices IQ 300

Metering Devices IQ 300 Effective: May 2001 Page 1 New Information Contents Description Page General Description......... 2 Specifications.............. 3 Field Wiring Connections.... 4 Page 2 Effective: May 2001 Applications

More information

Fronius IG Plus. The next generation grid-connected PV inverter.

Fronius IG Plus. The next generation grid-connected PV inverter. Fronius IG Plus The next generation grid-connected PV inverter. Maximum earnings. In any weather. The first multi-purpose device. Reliability and maximum earnings security. An outstanding addition to the

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options

More information

LED Driver Compact fixed output

LED Driver Compact fixed output Driver LCI 42 W 9/15 ma TEC C TEC series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 9 or 1,5 ma Max. output power 42 W Nominal life-time up to 5, h

More information

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , , , , ,

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , , , , , COMPACT LED DRIVERS EasyLine SIMPLE FIX 186719, 186720, 186721, 186722, 186723, 186724, 186725, 186726, 186727, 186728 Typical Applications Built-in in compact luminaires Shop lighting Downlights EasyLine

More information

Max. Input Power (W) Input Current. Inrush Current

Max. Input Power (W) Input Current. Inrush Current Output Power (W) Output Voltage (V) Output Current (A) Efficiency Tcase Max Input Current Max. Input Power (W) Inrush Current (Apk/µs) Max. THD (%) Min. Power Factor Surge Protection (KV) Weight (Lbs)

More information

Purpose of High Voltage Circuit Switchers

Purpose of High Voltage Circuit Switchers Purpose of High Voltage Circuit Switchers Vertical interrupter circuit switcher without integral disconnect switch (Figure 2) Three-phase Interruption and Protection Circuit switchers have been developed

More information

AE/CE Series Industrial Control Transformers

AE/CE Series Industrial Control Transformers AE/E SERIES INDUSTRIAL ONTROL TRANSFORMERS AE/E Series Industrial ontrol Transformers The Acme Electric AE and E Series Industrial ontrol Transformers are designed specifically for machine tool control

More information

Supplement to Instruction Manual

Supplement to Instruction Manual Supplement to Instruction Manual Compact Inverter 0 V series: FRN0001 to 00C2S-2 400 V series: FRN0002 to 0011C2S-4 Single-phase 0 V series: FRN0001 to 0012C2S-7 Thank you for purchasing our FRENIC-Mini

More information

QUINT-PS/24DC/48DC/ 5

QUINT-PS/24DC/48DC/ 5 Extract from the online catalog QUINT-PS/24DC/48DC/ 5 Order No.: 2320128 QUINT DC/DC converter, primary-switched, input: 24 V DC, output: 48 V DC/5 A Commercial data GTIN (EAN) sales group Pack Catalog

More information

Q-LINK SMART BYPASS. SIZING INFORMATION TABLE Q-Link Variable Frequency Drive - 3-Phase 208 VAC 230 VAC VAC HP FLA HP FLA HP FLA TECHNOLOGIES

Q-LINK SMART BYPASS. SIZING INFORMATION TABLE Q-Link Variable Frequency Drive - 3-Phase 208 VAC 230 VAC VAC HP FLA HP FLA HP FLA TECHNOLOGIES Q-LINK SMRT BYPSS 1 28, 208 480VC, 3Ø UL Type 1 Enclosure The is an integrated solution for critical applications without compromising for communications and motor protection. Unlike traditional bypasses,

More information

CC COMPACT DIP SWITCH

CC COMPACT DIP SWITCH CC COMPACT DIP SWITCH COMFORTLINE DIP SWITCH C-R5 186841, 186842, 186843 Typical Applications Built-in in compact luminaires for Shop lighting Downlights Panels ComfortLine DIP switch C-R5 SELECTABLE OUTPUT

More information

LINEAR LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

LINEAR LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , LINEAR LED DRIVERS EasyLine SIMPLE FIX 186712, 186713, 186714, 186715, 186716, 186760 Typical Applications Built-in in linear luminaires for Office lighting Weatherproof Luminaires EasyLine Simple Fix

More information

LANDSCAPE TRANSFORMERS

LANDSCAPE TRANSFORMERS LANDSCAPE TRANSFORMERS Precision Power. Perfect Light. Remote Transformers Linear Fluorescents Sign Ballasts Electronic HID LED Drivers Landscape Transformers Hatch Landscape Transformers have been designed

More information

Miniature Circuit-Breaker IEC Series 8562

Miniature Circuit-Breaker IEC Series 8562 > 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips

More information

SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module

SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module MODEL NUMBER: SV20KS1P0B Highlights Scalable capacity up

More information

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D.

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D. Electrical Integration of PV Systems Ridha Hamidi, Ph.D. 1 Many articles in the NEC are applicable to the electrical integration of a PV system, particularly Article 690. 2 The NEC defines the various

More information

QUINT-PS/ 1AC/24DC/20/CO

QUINT-PS/ 1AC/24DC/20/CO Extract from the online catalog QUINT-PS/ 1AC/24DC/20/CO Order No.: 2320898 DIN rail power supply unit 24 V DC/20 A/CO, dip-coated circuit board, primary-switched, 1-phase. For the first time, SFB (selective

More information

Applying branch circuit breakers and supplementary protectors in North America

Applying branch circuit breakers and supplementary protectors in North America Product Application AP01102005E WMZT WMZS Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers two types of miniature circuit breakers for use in North

More information

PowerLogic EM4000 series

PowerLogic EM4000 series PowerLogic Multi-circuit energy meters Technical datasheet Functions and characteristics PB113714 The compact PowerLogic multi-circuit energy meter from Schneider Electric enables reliable monitoring building

More information

C 2 5 D N A A A

C 2 5 D N A A A Product Family Overview May 007 pplication Description These Cutler-Hammer ampere and horsepower rated devices from Eaton s electrical business are designed for service in applications such as Refrigeration,

More information

AE/CE Series Industrial Control Transformers

AE/CE Series Industrial Control Transformers 5 AE/E Series Industrial ontrol Transformers SETION TA AE/E SERIES SERIES OPEN ORE INDUSTRIAL & OIL INDUSTRIAL ONTROL ONTROL TRANSFORMERS The Acme Electric AE and E Series Industrial ontrol Transformers

More information

KRH CVM DWR CDD REVISIONS NOTICE: THE INFORMATION AND DESIGN CONTAINED HEREIN IS THE PROPERTY OF TRANSTECTOR SYSTEMS. WHO RESERVES ALL RIGHTS THERETO

KRH CVM DWR CDD REVISIONS NOTICE: THE INFORMATION AND DESIGN CONTAINED HEREIN IS THE PROPERTY OF TRANSTECTOR SYSTEMS. WHO RESERVES ALL RIGHTS THERETO THIS SPECIFICTION HS BEEN GENERTED ND IS MINTINED BY CD SYSTEM. CHNGES SHLL ONLY BE INCORPORTED S DIRECTED BY THE DESIGN CTIVITY. REVISIONS LTR DESCRIPTION ECO NUM. DTE PPROVED E UPDTE PER REDLINES 13069

More information

Instructions. Interconnection Customer declares its intention to interconnect with the AEP Distribution System.

Instructions. Interconnection Customer declares its intention to interconnect with the AEP Distribution System. APPLICATION FOR INTERCONNECTION WITH THE Indiana Michigan Power Company INDIANA DISTRIBUTION SYSTEM (Project capacity greater than 10kW) Instructions Interconnection Customer declares its intention to

More information

SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules

SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules MODEL NUMBER: SVX90KM3P5B Highlights 90kVA/90kW Modular, Scalable,

More information

MP7. Uninterruptible Power Supply

MP7. Uninterruptible Power Supply Uninterruptible Power Supply PRODUCT SPECIFICATIONS Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,

More information

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V Characteristics soft starter for asynchronous motor - ATS01-32 A - 460..480 V Complementary Assembly style Function available Power supply voltage limits Main Range of product Altistart 01 Product or component

More information

LED Driver Compact fixed output

LED Driver Compact fixed output Driver LC 13W 3mA fixc C SNC ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 3 ma output power 13 W Nominal life-time up to 5, h For luminaires

More information

Redundant Bus Protection Using High-Impedance Differential Relays. Josh LaBlanc

Redundant Bus Protection Using High-Impedance Differential Relays. Josh LaBlanc Redundant Bus Protection Using High-Impedance Differential Relays Josh LaBlanc Purpose Discuss the configuration of the bus under study, and touch on the needs for redundant protection on the bus. Briefly

More information

Applying branch circuit breakers and supplementary protectors in North America

Applying branch circuit breakers and supplementary protectors in North America Supersedes June 2017 FAZ-NA-L FAZ-NA FAZ Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers three types of miniature circuit breakers for use in North

More information

ASCO SERIES 300 Manual Transfer Switch Solutions

ASCO SERIES 300 Manual Transfer Switch Solutions ASCO SERIES 300 Manual Transfer Switch Solutions When power fails, businesses suffer. For some organizations, a permanent generator is too costly. Instead, permanent means for quickly connecting a portable

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

Midwest Energy, Inc. Distributed Generation Interconnection Expedited & Standard Process Application

Midwest Energy, Inc. Distributed Generation Interconnection Expedited & Standard Process Application Midwest Energy, Inc. Distributed Generation Interconnection Expedited & Standard Process Application Instructions To submit an application to interconnect a generating facility using the Expedited or Standard

More information

CROWN CLIP Series Sockets

CROWN CLIP Series Sockets OWN LIP Series Sockets Product Facts ompact design High performance OWN BND contacts urrents to 350 mps 1 Mates with solid or laminated blades Supports true hot-plug (current interruption)2 Float-mount

More information

Power Switching & Controls for Business-Critical Continuity

Power Switching & Controls for Business-Critical Continuity Power Switching & Controls for usiness-critical Continuity 4-hour protection no matter when trouble strikes SCO Series 00 Power Transfer Switches for Power Outage Protection Where would you be without

More information

QUINT-PS/ 1AC/24DC/ 5

QUINT-PS/ 1AC/24DC/ 5 Extract from the online catalog QUINT-PS/ 1AC/24DC/ 5 Order No.: 2866750 DIN rail power supply unit 24 V DC/5 A, primary switched-mode, 1- phase. The SFB technology (Selective Fuse Breaking Technology)

More information

Model: KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

Model: KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units. Model: KEP Automatic Transfer Switches Service Entrance Rated Controller D Decision-Makerr MPAC 1500 Ratings Power Switching Device Molded case (MCCB) Insulated Case (ICCB) Current Voltage, Frequency 200

More information

APG/UPG/IPG Series Existing Designs Only APG/UPG/IPG

APG/UPG/IPG Series Existing Designs Only APG/UPG/IPG APG/UPG/IPG Series Existing Designs Only APG/UPG/IPG APG/UPG/IPG Series Hydraulic Magnetic Circuit Protectors INTRODUCTION IMPORTANT NOTICE: The APG/UPG is a legacy product and no new design-in orders

More information

Miniature Circuit Breakers and Supplementary Protectors. Contents

Miniature Circuit Breakers and Supplementary Protectors. Contents . Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.

More information

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH) COMPACT LED DRIVERS PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH) 186762, 186763 Typical Applications Built-in in compact luminaires Shop lighting Downlights PrimeLine DALI dimmable & Selectable

More information

SmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules

SmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules SmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules MODEL NUMBER: SV40KM2P2B Highlights Scalable capacity up to

More information

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output Driver LC 2W 2/3/3/mA fixc lp SNC ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 2, 3, 3 or ma Max. output power 2 W For luminaires of protection

More information

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-PS/1AC/24DC/10 Order No.: 2866763 DIN rail power supply unit 24 V DC/10 A, primary-switched mode, 1- phase. The SFB technology (Selective Fusebreaking Technology)

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operation Manual APC 2X Series Hardwire Products PMP2X-A PMF2X-A PMG2X-A PMH2X-A APC hardwired products are designed to provide specification-grade performance at the service entrance,

More information

Electrical Plan Review

Electrical Plan Review Electrical Plan Review Overcurrent Protection and Devices, Short-Circuit Calculations, Component Protection, Selective Coordination, and Other Considerations Table of Contents Part I: Overcurrent Protection

More information