NetApp NS0-156_formatted
|
|
- Jeremy Perry
- 5 years ago
- Views:
Transcription
1 NetApp NS0-156_formatted Number: Passing Score: 800 Time Limit: 120 min File Version: NetApp NS0-156 Data ONTAP Cluster-Mode Administrator Version: 6.1
2 Exam A QUESTION 1 Which statement is true about a Data Protection (DP)-type SnapMirror destination volume? A. It can be in a Data ONTAP GX cluster. B. It must be on the same disk type as the source volume. C. It can be smaller than the source volume. D. It can be on a different disk type than the source volume. Correct Answer: D QUESTION 2 To operate Data ONTAP 8.1 Cluster-Mode SAN, what must be configured on both the initiator and target? A. Logical Unit Access Initialization B. Physical Unit Access Initialization C. Symmetric Logical Unit Access D. Asymmetric Logical Unit Access E. SAN Access Initialization Protocol Correct Answer: D QUESTION 3 Which command can be used to identify the target iqn name in Data ONTAP 8.1 Cluster-Mode and later? A. cluster iscsi name B. cluster iscsi nodename C. cluster iscsi show D. vserver iscsi nodename E. vserver iscsi name F. vserver iscsi show Correct Answer: F QUESTION 4 What does Storage Failover allow? A. disks to fail over between HA partners B. disks to fail over to a plex
3 C. disks to fail over to any node in a cluster D. disks to fail over to the Epsilon node Correct Answer: A QUESTION 5 Which five protocols are supported by Data ONTAP 8.1 Cluster-Mode? (Choose five.) A. CIFS B. FC C. FCIP D. FCoE E. ifcp F. iscsi G. NFS Correct Answer: ABDFG QUESTION 6 Which two methods expose volumes to NAS clients? (Choose two.) A. mount directories of a volume in a namespace B. mount the required namespaces in a volume C. mount the required namespaces in an aggregate D. mount the required volumes in a namespace Correct Answer: AD QUESTION 7 Which storage system combination is supported in Cluster-Mode? A. a pair of FAS3270s and a pair of FAS3020s
4 B. a pair of FAS3270s with a FAS3240 and a FAS6240 C. a pair of FAS6280s and a pair of E7900s D. a pair of FAS6280s and a pair of FAS3240s Correct Answer: D QUESTION 8 Which two statements are true in a SnapMirror LS mirror relationship? (Choose two.) A. Client requests to write data are allowed if the user is root. B. Client requests to write data are denied unless accessing the admin share. C. Client requests to read data are only allowed if the mirror is up-to-date. D. Client requests to read data are redirected to the LS mirror destination volumes. Correct Answer: BD QUESTION 9 Which two SMB versions does Data ONTAP Cluster-Mode support? (Choose two.) A. SMB 1.0 B. SMB 2.0 C. SMB 3.0 D. SMB 4.0 Correct Answer: AB QUESTION 10 How does the NetApp Remote Support Agent (RSA) connect to NetApp Support? A. NetApp Support initiates a secure connection to the RSA. B. NetApp Support initiates a non-secure connection to the RSA. C. The RSA initiates a secure connection to NetApp Support. D. The RSA initiates a non-secure connection to NetApp Support. Correct Answer: C
5 QUESTION 11 The VLDB is out-of-quorum on the node serving as the master of the VLDB ring. Which four statements are true? (Choose four.) A. A new VLDB ring master is elected. B. Clients can write to volumes on that node. C. Volumes cannot be moved to or from that node. D. Clients can read from volumes hosted on that node. E. New volumes can be created on aggregates hosted on that node. Correct Answer: ABCD QUESTION 12 With Data ONTAP 8.1, which statement is true about deduplication and volume sizes? A. Deduplication is limited to 16TB. B. Deduplication is limited to 32TB. C. Deduplication is supported up to half the maximum volume size for the platform. D. Deduplication is supported up to the maximum volume size for the platform. Correct Answer: D QUESTION 13 Which three NFS versions does Data ONTAP 8.1 Cluster-Mode support? (Choose three.) A. NFSv.0 B. NFSv.1 C. NFSv1.1 D. NFSv3.0 E. NFSv4.0 F. NFSv4.1 G. NFSv5.0 Correct Answer: DEF QUESTION 14 What kind of structure can be deduplicated? A. A disk
6 B. An aggregate C. A FlexVol D. A qtree Correct Answer: C QUESTION 15 Which parameter must the cluster administrator properly define when configuring an iscsi logical interface in Data ONTAP 8.1 Cluster-Mode and later? A. data-access B. data-address C. data-protocol D. data-routing E. No parameter needs to be defined as no additional parameter is required. Correct Answer: C QUESTION 16 Which two LIFs are able to failover or migrate to other nodes in the cluster? (Choose two.) A. cluster LIF B. data LIF of protocol CIFS C. data LIF of protocol FCoE D. data LIF of protocol iscsi E. data LIF of protocol NFS F. intercluster LIF G. node management LIF Correct Answer: BE QUESTION 17 Where can NDMP backups be performed? A. within the Vserver context B. on the OnCommand server C. from any node in the cluster D. from the node that owns the volume
7 Correct Answer: D QUESTION 18 Which four statements are true about a node's vol0 volume? (Choose four.) A. It cannot be moved with the volume move command. B. It contains RDB databases and log files. C. It is the most efficient place to store critical user data. D. It is not part of the namespace. E. One exists on every node in the cluster. Correct Answer: ABDE QUESTION 19 Protocol access is provided to data via what? A. a cluster B. a virtual filer C. a virtual server D. a high-available pair of storage systems Correct Answer: C QUESTION 20 What is the maximum number of nodes a SAN cluster in DOT 8.1 can have? A. 1 B. 2 C. 6 D. 8 E. 16 F. 24 G. 32 Correct Answer: C
8 QUESTION 21 Which two Data ONTAP Cluster-Mode clone technologies will lock a Snapshot copy? (Choose two.) A. FlexClone B. LUN Clone C. Snap Clone D. Vol Clone E. Aggr Clone Correct Answer: AB QUESTION 22 NetApp Remote Support Agent (RSA) is supported on which two FAS module types? (Choose two.) A. BMC B. ILO C. RLM D. RTC E. SP Correct Answer: CE QUESTION 23 Which resource is associated with all logical interfaces? A. cluster B. cluster-routes C. group-routes D. port E. VServer-routes Correct Answer: D QUESTION 24 What are four characteristics of a NAS LIF? (Choose four.) A. It has a logical interface connection. B. It can be associated with a Fibre Channel port.
9 C. It can be associated with a WWPN. D. It can be associated with an Ethernet port. E. It can be associated with an interface group (ifgrp). F. It can be associated with an IP address. Correct Answer: ADEF QUESTION 25 What is the GUI-based interface that manages a cluster? A. Cluster Bench B. Device Manager C. FilerView D. Node Studio E. System Manager Correct Answer: E QUESTION 26 Which statement is true about establishing a SnapMirror relationship? A. It sets up the relationship on the source node only. B. It sets up the relationship and starts the initial data transfer. C. It sets up the relationship and creates the destination volume. D. It sets up the relationship, but does not start the initial transfer. Correct Answer: D QUESTION 27 What must be defined in order to create an NFS export within Cluster-Mode? A. an entry in the /etc/exports file B. an export policy and rules under a Vserver C. an export policy and rules under the FreeBSD shell D. an export policy and rules under the node shell E. export rules that are associated with a LIF Correct Answer: B
10 QUESTION 28 Which two switches are supported cluster switches? (Choose two.) A. Brocade 8000 B. Brocade FLS624 C. Cisco Nexus 5010 D. Cisco Nexus 5020 E. Cisco Catalyst 2960 Correct Answer: CD QUESTION 29 What are four storage efficiency features Data ONTAP 8.1 Cluster-Mode provides? (Choose four.) A. compression B. deduplication C. FlexClone D. SnapVault E. thin provisioning F. transparent files Correct Answer: ABCE QUESTION 30 Which three storage features can be scaled by storage administrators? (Choose three.) A. capacity scaling, by allowing more than two storage systems to be combined with larger disk shelves B. energy scaling, by allowing the cluster to share the same power source C. heterogeneous scaling, by allowing E-Series and FAS-Series systems within a single cluster D. network scaling, by providing three or more network switches for the cluster network E. operational scaling, by allowing the entire cluster to be administrated through a single resilient interface F. performance scaling, by using Flash Cache, SSDs, and Quality of Service Correct Answer: AEF
11 QUESTION 31 Which type of LIF allows replication between two clusters? A. cluster B. cluster-mgmt C. data D. intercluster E. node-mgmt Correct Answer: D QUESTION 32 One node of a 2-node cluster is shut down to replace a NIC. All RDB rings fall out of quorum. To diagnose the problem, what should the administrator do first? A. disconnect and reconnect the InfiniBand cable B. issue storage failover show from the clustershell C. issue cluster ha show from the clustershell D. verify that the cluster switch is functioning properly Correct Answer: C QUESTION 33 Which is a supported management switch? A. Brocade 8000 B. Brocade FLS624 C. Cisco Nexus 5010 D. Cisco Nexus 7000 E. Cisco Catalyst 2960 F. Cisco Nexus 5020 Correct Answer: E QUESTION 34 Which statement is true about a SnapMirror destination Vserver? A. It must have a read-only Vserver root volume. B. It must be in the same cluster as the source Vserver.
12 C. It must be created with the same language type as the source Vserver. D. It must have a different storage efficiency policy than the source Vserver. Correct Answer: C QUESTION 35 NFSv4.1 pnfs reduces traffic over which network? A. cluster network B. data network C. InfiniBand network D. management network Correct Answer: A QUESTION 36 Using the following path: /users/sales/a1/smith, which are the two possible path types for a1? (Choose two.) A. a directory B. a file C. a LUN D. a qtree Correct Answer: AD QUESTION 37 Which command configures the Remote Support Agent (RSA)? A. rsa init B. system services web C. system services rsa D. vserver services rsa Correct Answer: B
13 QUESTION 38 Which statement is true about expanding an aggregate from 32-bit to 64-bit in place? A. The expansion is triggered by an aggr convert command. B. The expansion is triggered by adding disks to exceed 16TB. C. All aggregates are automatically converted from 32-bit to 64-bit with the Data ONTAP 8.1 upgrade. D. 32-bit aggregates are degraded and must be Volume SnapMirrored to new 64-bit aggregates with the Data ONTAP 8.1 upgrade. Correct Answer: B QUESTION 39 What should an administrator do first before shutting down two nodes of a 4-node cluster? A. migrate node-management LIFs to a node that is staying up B. move Vserver root volumes to a node that is staying up C. reassign the master of all RDB rings to a node that is staying up D. set both nodes that are coming down to "ineligible" Correct Answer: D QUESTION 40 Which two Data ONTAP Cluster-Mode clone technology can clone an individual LUN inside a volume without cloning the entire volume? A. FlexClone B. LUN Clone C. Snap Clone D. Vol Clone E. Aggr Clone Correct Answer: BD QUESTION 41 What are two ways a storage administrator can improve the operational availability of NAS application data? (Choose two.) A. by backing up data to a USB disk B. by configuring ALUA on the host C. by providing multiple data logical interfaces
14 D. by utilizing the volume move feature Correct Answer: CD QUESTION 42 Which four features does Cluster-Mode support? (Choose four.) A. data protection mirrors B. load-sharing mirrors C. NDMP tape backup D. non-disruptive upgrades E. synchronous SnapMirror Correct Answer: ABCD QUESTION 43 What is the maximum number of nodes in a cluster that the Cisco Nexus 5010 supports? A. 12 B. 18 C. 20 D. 24 Correct Answer: B QUESTION 44 The Catalyst 2960 can be used only on the management network for clusters that have nodes. A. 12 B. 16 C. 18 D. 20 E. 24 Correct Answer: E
15 QUESTION 45 When using Data ONTAP 8.1 Cluster-Mode and later, what is the default for new aggregates? A. 32-bit aggregates B. 64-bit aggregates C. 128-bit aggregates D. cluster aggregates E. traditional aggregates F. Vserver aggregates Correct Answer: B QUESTION 46 Which feature makes it possible for a storage administrator to add more than two storage systems to a cluster? A. Scale horizontal B. Scale out C. Scale up D. Scale vertical Correct Answer: B QUESTION 47 Which statement is true about NFS exports in Cluster-Mode? A. Export policies are created and modified by editing /etc/exports. B. Exports can be either persistent or temporary. C. Export policies and rules are stored in the RDB. D. Both A and B E. Both B and C Correct Answer: C QUESTION 48 In a 2-node cluster with cluster HA enabled, which node has Epsilon by default? A. the first node to join the cluster B. the node that's been running for the longest amount of time
16 C. the node serving as mgwd ring master D. the node with the lower system ID E. neither node Correct Answer: E QUESTION 49 What are two defaults for a new Data ONTAP 8.1 or later system root aggregate? (Choose two.) A. 32-bit B. 64-bit C. 0% aggr reserve D. 5% aggr reserve Correct Answer: BC QUESTION 50 What must be configured to support cross-cluster SnapMirror relationships? A. cluster peer relationship B. intracluster port C. junction path D. minimum transfer size Correct Answer: A QUESTION 51 What communication link is necessary in order to establish cluster peer relations between two clusters? A. The cluster interface on each node must be able to communicate with the intracluster interface on each node in the peer cluster. B. The cluster interface on each node must be able to communicate with the node-mgmt interface on each node in the peer cluster. C. The intracluster interface on each node must be able to communicate with the intracluster interface on each node in the peer cluster. D. The intercluster interface on each node must be able to communicate with the intercluster interface on each node in the peer cluster. Correct Answer: D
17 QUESTION 52 A volume named volume217 resides on an aggregate named node7_aggr12 and is mounted in the namespace at junction /source/april/test217. A file named revert.cpp is at the root of volume217. A volume move operation relocates volume217 to node3_aggr3. What is the fully qualified path to revert.cpp after the move is complete? A. /node3_aggr3/source/april/test217/revert.cpp B. /node3_aggr3/volume217/revert.cpp C. /source/april/test217/revert.cpp D. /vol/source/april/test217/revert.cpp E. /vol/volume217/revert.cpp Correct Answer: C QUESTION 53 How many cluster switch(es) are required for a NetApp cluster? A. 1 B. 2 C. 4 D. 6 Correct Answer: B QUESTION 54 A FAS6280 running ONTAP 8.0.2P1 has a 32-bit root aggregate. After upgrading to Data ONTAP 8.1, what is the status of the root aggregate? A. The root aggregate remains 32-bit. B. The root aggregate converts from 32 to 64-bit in place. C. The root aggregate auto-migrates to a new 64-bit aggregate. D. The upgrade fails with a message to create a new 64-bit aggregate before upgrade. Correct Answer: A QUESTION 55 Which four steps must an administrator take before establishing a CIFS share? (Choose four.)
18 A. create a volume B. configure a share policy with the desired values C. configure an export policy D. configure name mapping E. enable Active Directory routing F. mount a volume within the Vserver namespace G. set a default share policy Correct Answer: ACDF QUESTION 56 Volumes can be moved from 32-bit aggregates to which two types of aggregates? (Choose two.) A. 32-bit aggregates B. 64-bit aggregates C. flex aggregates D. traditional aggregates Correct Answer: AB QUESTION 57 An administrator for a virtual server named abc17 mounts a new volume named vola at junction named / accounting/teama and creates two directories at the root of the new volume named 2011 and 2011/june. He also copies a file called report.doc into the directory named june. An NFS client mounts to the root of the namespace. What is the fully qualified path to report.doc? A. /abc17/accounting/teama/2011/june/report.doc B. /accounting/teama/2011/june/report.doc C. /accounting/vola/teama/2011/june/report.doc D. /vol/vola/2011/june/report.doc E. Z:\vola\2011\june\report.doc Correct Answer: B
19 QUESTION 58 What three statements are true about LIF failover? (Choose three.) A. A data Ethernet LIF fails over when the cluster is in quorum. B. A cluster management Ethernet LIF fails over when a port is down. C. A cluster management Ethernet LIF will never automatically revert back to its home port. D. A data Ethernet LIF will not revert back by default to its home port. E. A node management Ethernet LIF fails over when a port is down. F. A node management Ethernet LIF will never automatically revert back to its home port. Correct Answer: ADF QUESTION 59 What is the maximum number of nodes a NAS cluster can have? A. 1 B. 2 C. 4 D. 8 E. 16 F. 24 G. 32 Correct Answer: F QUESTION 60 Which statement is true about converting an aggregate from 32-bit to 64-bit? A. It is supported when adding disks. B. It is supported without adding disks. C. It is supported in maintenance mode. D. It is not supported. You must use VSM to migrate 32-bit to 64-bit. Correct Answer: A
20 QUESTION 61 Which five protocols are supported by Data ONTAP 8.1 Cluster-Mode or later? (Choose five) A. iscsi B. FCIP C. CIFS D. FC E. FCoE F. IFCP G. NFS Correct Answer: ACDEG (see multi-tenancy, 3rd para) QUESTION 62 Which three SMB versions do Data ONTAP Cluster Mode 8.1 and later support? (Choose three.) A. SMB 4.0 B. SMB 3.0 C. SMB 2.1 D. SMB 2.0 E. SMB l.0 Correct Answer: CDE Reference: (see smb 2.0 and 2.1) QUESTION 63 Which two actions protect an Infinite volume from the loss of a namespace constituent? (Choose two) A. Minor the namespace constituent by using an intracluster data protection mirror B. Mirror the namespace constituent by using an Intercluster data protection mirror C. Mirror the namespace constituent by using a load-sharing mirror D. Mirror the namespace constituent by using a FlexCache mirror Correct Answer: BC
21 QUESTION 64 In Data ONTAP Cluster-Mode, what is the maximum TCP read size for an NFSv3 client? A. l,048,576 bytes B. 32,768 bytes C. 65,536 bytes D. 2,097,152 bytes Correct Answer: A Reference: QUESTION 65 What are three types of Vservers? (Choose three.) A. vfiler B. node C. intercluster D. cluster E. admin F. data Correct Answer: BEF Reference: QUESTION 66 In Data ONTAP Cluster-Mode, what is the maximum cluster size for SAN protocols? (Choose Three) A. l0 nodes B. 6 nodes C. 2 nodes D. 4 nodes E. 8 nodes F. 12 nodes Correct Answer: BCD Reference: NPA_2013_Pavlicek.pdf (slide 28) QUESTION 67 Which NetApp Virtual Storage Tier component works aggregate-wide on a FAS controller? A. Flash IO
22 B. Flash Cache C. Flash Accel D. Flash Disk E. Flash Pool Correct Answer: B Reference: QUESTION 68 Prior to breaking a SnapMirror DP relationship, which statement is true about mounting the destination volume? A. It can be mounted in the namespace of any Vserver in the source- or destination cluster. B. It cannot be mounted until after the SnapMirror break is performed. C. It can be mounted in the namespace of the destination Vserver. D. It can be mounted only in the same namespace as the source volume. Correct Answer: C QUESTION 69 Which Data ONTAP Cluster-Mode clone technology will lock a Snapshot copy? A. LUN Clone B. Snapshot Clone C. Volume Clone D. Aggr Clone Correct Answer: A QUESTION 70 What happens if a load Sharing (LS) mirror replies a Vserver root volume to any node in the cluster and you promote one of the mirror destinations? A. All clients temporarily gain read/write access to the root volume B. The original source volume is prevented from becoming stale. C. All clients must re mount. D. There is no disruption for any connected clients. Correct Answer: A
23 QUESTION 71 Which two now features are available in Data ONTAP C-Mode? (Choose two.) A. Flash pool B. SSD Support C. Infinite volume D. Infiniband Correct Answer: BC QUESTION 72 What two actions should an administrator take before shutting down two nodes of a 4-node cluster? (Choose two.) A. reassign the master of all RDB rings to a node that will be staying up B. migrate node-management LIFs to a node that will be staying up C. move Vserver root volumes to a node that will be staying up D. set both nodes that are coming down to "ineligible" E. ensure that Epsilon is assigned to one of the nodes that will be staying up Correct Answer: DE QUESTION 73 What are the three types of resources supported by logical interfaces? (Choose three.) A. VServer-routes B. port C. Interface groups D. failover groups E. cluster-routes F. cluster G. group-routes H. VLAN Correct Answer: BCH QUESTION 74
24 Which statement is true about NFS exports in Data ONTAP Cluster-Mode? A. Export policies are created and modified by editing /etc/exports. B. Exports can be either persistent or temporary. C. Export policies and rules are stored in the RDB. D. Both A and B E. Both B and C Correct Answer: C QUESTION 75 In Data ONTAP Cluster-Mode, what is the maximum node size for SAN protocols? (Choose three) A. 24 nodes B. 12 nodes C. 8 nodes D. 6 nodes E. 4 nodes F. 2 nodes Correct Answer: DEF QUESTION 76 Which Data ONTAP Cluster-Mode clone technology can clone an individual LUN Inside a volume without cloning the entire volume? A. FlexClone B. LUN Clone C. Snap Clone D. Vol Clone E. Aggr Clone Correct Answer: B QUESTION 77 Which boot argument toggles between 7-Mode and Cluster-Mode configurations? A. bootarg.init.boot_gx B. bootarg.init.boot_7-mode
25 C. bootarg.init.boot_cluster-mode D. bootarg.init.boot_clustered Correct Answer: D QUESTION 78 Which security style is supported with Infinite Volumes? A. Block B. NTFS C. Unix security style D. Mixed Correct Answer: C Reference: QUESTION 79 Which are two requirements for the Cluster-Mode solution? (Choose two.) A. Thunderbolt or LightPeak cabling with backplane interface on storage B. Management switches C. InfiniBand cabling with backplane interface for all storage systems D. FC Cluster switches E. Cluster switches Correct Answer: CE QUESTION 80 To support multi-tenancy, an administrator must create or enable which type of unique login account? A. vsadmin, for the cluster B. admin, for each Vserver C. admin, for the cluster D. vsadmin, for each Vserver Correct Answer: D
26 QUESTION 81 What are two capabilities of Vserver setup? (Choose two) A. It licenses Vserver functionality. B. It joins an existing Vserver to the cluster. C. It creates a new Vservers that can host FCP LUNs. D. It creates a new cluster Vservers. E. It configures an existing Vserver. Correct Answer: BD QUESTION 82 Which NetApp Virtual Storage Tier component works controller-wide on a FAS controller? A. Flash Pool B. Flash IO C. Flash Cache D. Flash Accel E. Flash Disk Correct Answer: C QUESTION 83 Which aggregate type is supported for Flash Pool? A. Traditional B. 32-bit C. 64 bit D. 128-bit Correct Answer: C QUESTION 84 Which NetApp Virtual Storage Tier component works at the host level? A. Flash Pool B. Flash IO C. Flash Disk
27 D. Flash Accel E. Flash Cache Correct Answer: D Reference: QUESTION 85 Which version of Data ONTAP first supports Flash Pool? A. Data ONTAP Cluster-Mode B. Data ONTAP 7.3 C. Data ONTAP Mode D. Data ONTAP 8.1 Cluster-Mode Correct Answer: A Reference: (See,flash pool technology) QUESTION 86 Which three network switches are supported in Data ONTAP Cluster Mode? (Choose two.) A. Nexus 5010 B. Nexus 5020 C. CN1601 D. CN1610 Correct Answer: ABD QUESTION 87 Which storage system combination is supported in a 4-node cluster? A. a pair of FAS3270s and a pair of FAS3020s B. a pair of FAS3270s with a FAS3240 and a FAS6240 C. a pair of FAS6280s and a pair of E7900s D. a pair of FAS6280s and a pair of FAS3240s Correct Answer: D
28 QUESTION 88 What are four storage efficiency features that Data ONTAP 8.1 or later Cluster-Mode provides? (Choose four.) A. transparent files B. thin provisioning C. SnapVault D. FlexClone E. deduplication F. compression Correct Answer: BDEF QUESTION 89 Which protocol(s) does Infinite Volumes support? A. All supported protocols on Data ONTAP B. NFSv3 and NFSv4 only C. NFS v2 and NFSv3 only D. NFSv3 only E. NFSv3 and SMB 1.0 only Correct Answer: D Reference: QUESTION 90 What three statements are true about LIF failover? (Choose three.) A. A node management Ethernet LIF will never automatically revert back to its home port. B. A node management Ethernet LIF can fail over to its partner node when a port is down. C. A data Ethernet LIF will not automatically revert back to its home port. D. A cluster management Ethernet LIF will never automatically revert back to its home port E. A cluster management Ethernet LIF can fail over when a port is down. F. A data Ethernet LIF can fail over when the cluster is in quorum. Correct Answer: ACF QUESTION 91 Which three disk-type configurations are supported for Flash Pool? (Choose three)
29 A. FC and SAS B. FC and SSD C. SATA and SAS D. SATA and SSD E. SSD and SAS Correct Answer: BDE QUESTION 92 Which three are components of the NetApp Virtual Storage Tier (VST)? (Choose three) A. Flash Accel B. Flash Cache C. Flash Disk D. Flash IO E. Flash Pool Correct Answer: ABE Reference: (see figure 1) QUESTION 93 What is the default system account? A. admin B. admin_user C. administrator D. root Correct Answer: A QUESTION 94 Administrators can natively run Data ONTAP 7-Mode commands in what shell? A. Adminshell B. Clustershell C. Nodeshell D. Systemshell Correct Answer: C
30 QUESTION 95 What command starts recording the current CLI session into a file? A. system cli record B. system record start C. system script record D. system script start Correct Answer: D QUESTION 96 To maintain a cluster quorum, Epsilon functions as a. A. duplicated management database B. master node C. secondary node D. tie-breaker Correct Answer: D QUESTION 97 A cluster node is a(n). A. Admin node B. Cluster vsetver C. HA storage controller pair D. Storage controller Correct Answer: D QUESTION 98 New systems are shipped with the root volume in a 64-bit aggregate starting with which Data ONTAP release? A B
31 C D. 8.1 Correct Answer: D QUESTION 99 How many cluster ports does each node have by default? A. One B. Two C. Three D. Four Correct Answer: B QUESTION 100 What three cluster administrator roles are predefined? (Choose three.) A. admin B. backup C. none D. readonly E. root F. vsadmin Correct Answer: ACD QUESTION 101 What two Vserver administrator roles are predefined? (Choose two.) A. admin B. readonly C. root D. vsadmin E. vsadmin-readonly Correct Answer: DE
32 QUESTION 102 What three protocols obtain the Data ONTAP software image? (Choose three.) A. CIFS B. FTP C. HTTP D. HTTPS E. NFS F. TFTP Correct Answer: BCF QUESTION 103 What two logical interfaces have failover and migration capabilities? {Choose two.) A. client B. cluster management C. controller D. data E. node management Correct Answer: BD QUESTION 104 What three privilege levels are found in clustered Data ONTAP? (Choose three.) A. admin B. advanced C. backup D. diagnostic E. manage F. single_user Correct Answer: ABD QUESTION 105 What are the four replicated database rings in a cluster? (Choose four.)
33 A. administration (admdb) B. logical-interface manager (lifmgr) C. management application (mgmt) D. protocol management daemon (prtodb) E. SAN management daemon (bcomd) F. virtual-interface manager (vifmgr) G. volume location database (vldb) Correct Answer: CEFG QUESTION 106 Which two Vservers are created automatically by the cluster setup process? (Choose two.) A. Admin B. Data C. Management D. Node E. Protocol Correct Answer: AD QUESTION 107 When a pnfs 4.1 client is connected to a LIF on node 2 of an 8 node clustered Data ONTAP pnfs 4.1 Vserver, and the data volume being read is moved to node 1, which statement is true? A. The client redirects from a LIF on node 2 to a LIF on node 1 if available and continues data access uninterrupted. B. The client stays connected to a LIF on node 2 and accesses the data on node 1 through the cluster network. C. DNS records are updated and the client moves access to a LIF on node 1 from DNS referral. D. When a data volume is moved, only CIFS clients are affected. Correct Answer: A QUESTION 108 For RAID-DP aggregates created with clustered Data ONTAP 8.2 or later, what is the default minimum number of disks? A. 1
34 B. 2 C. 3 D. 4 E. 5 F. 6 G. 10 Correct Answer: E QUESTION 109 Which two NetApp tools perform pre-checks to determine whether a NAS environment meets the requirements for transitioning from 7-Mode to clustered Data ONTAP? (Choose two.) A. 7-Mode Transition Tool B. Clustered ONTAP Transition Tool C. Migration Checklist D. Transition Advisor E. Transition Deck Correct Answer: AD QUESTION 110 Within clustered Data ONTAP 8.2 or later, which two functionalities are supported with an external asynchronous FPolicy server? (Choose two.) A. Audit logging B. Compression and decompression services C. Encryption and decryption services D. File access E. Hierarchical storage management Correct Answer: AD QUESTION 111 Which two statements are true with clustered Data ONTAP support of IPv6? (Choose two.) A. You can define multicast address B. You can define a link-local address C. You can define a look-back address
35 D. You must use a network mask of 64 E. You can define an address with 64-bit hexadecimal ID in prefix: id format Correct Answer: DE QUESTION 112 With clustered Data ONTAP 8.2, what two non-disruptive upgrade techniques are supported on clusters of 8 modes or more? (Choose two.) A. batch B. parallel C. rolling D. synchronous Correct Answer: AC QUESTION 113 Name two modes of BranchCache. (Choose two.) A. hosted B. distributed C. intercluster D. Vserver-aware Correct Answer: AB QUESTION 114 Identify two asynchronous Fpolicy applications. (Choose two.) A. Quota management B. File-access and audit logging C. Storage resource management D. Compression and decompression services Correct Answer: BC
36
NetApp. Number: NS0-156 Passing Score: 800 Time Limit: 120 min File Version: 1.0.
NetApp Number: NS0-156 Passing Score: 800 Time Limit: 120 min File Version: 1.0 http://www.gratisexam.com/ Exam A QUESTION 1 Which statement is true about a Data Protection (DP)-type SnapMirror destination
More informationNetapp.Examsheets.NS0-156.v by.Luger.154q. Exam Code: NS Exam Name: Data ONTAP Cluster-Mode Administrator
Netapp.Examsheets.NS0-156.v2014-01-15.by.Luger.154q Number: NS0-156 Passing Score: 800 Time Limit: 120 min File Version: 20.5 http://www.gratisexam.com/ Exam Code: NS0-156 Exam Name: Data ONTAP Cluster-Mode
More informationNetapp.Actualtests.NS0-156.v by.LIZZIE.154q
Netapp.Actualtests.NS0-156.v2014-05-26.by.LIZZIE.154q Number: NS0-156 Passing Score: 800 Time Limit: 120 min File Version: 20.5 http://www.gratisexam.com/ Exam Code: NS0-156 Exam Name: Data ONTAP Cluster-Mode
More informationTestkings NS q
Testkings NS0-156 307q Number: NS0-156 Passing Score: 800 Time Limit: 120 min File Version: 12.5 Network Appliance NS0-156 Data ONTAP Cluster-Mode Administrator Passed on 2-02-15 with an 890. Dump still
More informationns0-157 Passing Score: 700 Time Limit: 120 min File Version: 1.0
ns0-157 Passing Score: 700 Time Limit: 120 min File Version: 1.0 http://www.gratisexam.com/ Exam A QUESTION 1 An IPspace is associated with exactly one? A. broadcast domain B. SVM C. port D. root volume
More informationPASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year
PASS4TEST \ http://www.pass4test.com We offer free update service for one year Exam : NS0-157 Title : NetApp Certified Data Administrator, Clustered Data ONTAP Vendor : Network Appliance Version : DEMO
More informationExam Questions NS0-156
Exam Questions NS0-156 Data ONTAP Cluster-Mode Administrator http://www.2passeasy.com/dumps/ns0-156/ 1. What are the three types of Vservers in clustered Data ONTAP 8.2? (Choose all that apply) A. System
More informationInfinite Volumes Management Guide
ONTAP 9 Infinite Volumes Management Guide September 2016 215-11160_B0 doccomments@netapp.com Visit the new ONTAP 9 Documentation Center: docs.netapp.com/ontap-9/index.jsp Table of Contents 3 Contents
More informationOutline: ONTAP 9 Cluster Administration and Data Protection Bundle (CDOTDP9)
Outline: ONTAP 9 Cluster Administration and Data Protection Bundle (CDOTDP9) Cluster Module 1: ONTAP Overview Data Fabric ONTAP software Fabric layers The cluster Nodes High-availability pairs Networks
More informationNetwork- Appliance EXAM - NS NetApp Certified Implementation Engineer - SAN, Cluster-Mode. Buy Full Product
Network- Appliance EXAM - NS0-504 NetApp Certified Implementation Engineer - SAN, Cluster-Mode Buy Full Product http://www.examskey.com/ns0-504.html Examskey Network-Appliance NS0-504 exam demo product
More informationExam Questions NS0-157
Exam Questions NS0-157 NetApp Certified Data Administrator, Clustered https://www.2passeasy.com/dumps/ns0-157/ 1. Clustered Data ONTAP supports which three versions of NFS? (Choose three.) A. NFSv4.1 B.
More informationNetapp Exam NS0-157 NetApp Certified Data Administrator, Clustered Data ONTAP Version: 11.0 [ Total Questions: 302 ]
s@lm@n Netapp Exam NS0-157 NetApp Certified Data Administrator, Clustered Data ONTAP Version: 11.0 [ Total Questions: 302 ] https://certkill.com Topic break down Topic No. of Questions Topic 1: Volume
More informationNS
NS0-157 Number: 000-000 Passing Score: 800 Time Limit: 120 min File Version: 1.0 Netapp Exam NS0-157 NetApp Certified Data Administrator, Clustered Data ONTAP Экзамен A QUESTION 1 What communication link
More informationClustered Data ONTAP Administration and Data Protection
Clustered Data ONTAP Administration and Data Protection COURSE OVERVIEW: This course uses lecture and hands-on exercises to teach basic administration of clustered Data ONTAP. In this course, you will
More informationCluster Management Workflows for OnCommand System Manager
ONTAP 9 Cluster Management Workflows for OnCommand System Manager August 2018 215-12669_C0 doccomments@netapp.com Table of Contents 3 Contents OnCommand System Manager workflows... 5 Setting up a cluster
More informationClustered Data ONTAP Administration (DCADM)
Clustered Data ONTAP Administration (DCADM) COURSE OVERVIEW: This course uses lecture and hands-on exercises to teach basic administration of clustered Data ONTAP. In this course you configure and manage
More informationClustered Data ONTAP 8.3 Administration and Data Protection Workshop
NA-CDOTDP-WS Clustered Data ONTAP 8.3 Administration and Data Protection Workshop Prerequisites A basic understanding of system administration with UNIX or Windows is recommended as well as the web-based
More informationONTAP 9 Cluster Administration. Course outline. Authorised Vendor e-learning. Guaranteed To Run. DR Digital Learning. Module 1: ONTAP Overview
ONTAP 9 Cluster Administration Course Code: Duration: 3 Days Product Page: https://digitalrevolver.com/product/ontap-9-cluster-administration-2/ This 3-day, instructor led course uses lecture and hands-on
More informationOnCommand Unified Manager 6.1
OnCommand Unified Manager 6.1 Administration Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277 Web:
More informationMonitoring and Reporting for an ONTAP Account
This chapter contains the following sections: About, page 1 About Disks, page 2 Managing Filers, page 3 Managing Virtual Machines, page 3 Managing Interfaces, page 6 Managing IP Spaces, page 7 Managing
More informationPASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year
PASS4TEST \ http://www.pass4test.com We offer free update service for one year Exam : NS0-504 Title : NetApp Certified Implementation Engineer - SAN, Cluster-Mode Vendor : Network Appliance Version : DEMO
More informationCluster Management Workflows for OnCommand System Manager
Clustered Data ONTAP 8.3 Cluster Management Workflows for OnCommand System Manager February 2016 215-10887_A0 doccomments@netapp.com Updated for 8.3.2 Table of Contents 3 Contents Contents of the Workflow
More informationNS0-158 netapp. Number: NS0-158 Passing Score: 800 Time Limit: 120 min.
NS0-158 netapp Number: NS0-158 Passing Score: 800 Time Limit: 120 min Exam A QUESTION 1 What are three causes of a storage failover partial giveback? (Choose three.) A. iscsi sessions are active. B. AutoSupports
More informationCluster Management Workflows for OnCommand System Manager
ONTAP 9 Cluster Management Workflows for OnCommand System Manager June 2017 215-11440-C0 doccomments@netapp.com Updated for ONTAP 9.2 Table of Contents 3 Contents OnCommand System Manager workflows...
More informationNS0-180 netapp
NS0-180 netapp Number: NS0-180 Passing Score: 800 Time Limit: 120 min Exam A QUESTION 1 You want to create a data volume on aggr0 and you receive a message with the following warning: ''Warning: You are
More informationNS0-191 netapp. Number: NS0-191 Passing Score: 800 Time Limit: 120 min.
NS0-191 netapp Number: NS0-191 Passing Score: 800 Time Limit: 120 min Exam A QUESTION 1 An administrator notices that the clustered Data ONTAP 8.2.3 controllers are less responsive than normal. You use
More informationOnCommand Unified Manager 6.1 Administration Guide
IBM System Storage N series OnCommand Unified Manager 6.1 Administration Guide SC27-6627-00 Table of Contents 3 Contents Preface... 7 Supported features... 7 Websites... 7 Getting information, help, and
More informationNS Number: NS0-507 Passing Score: 800 Time Limit: 120 min File Version: NS0-507
NS0-507 Number: NS0-507 Passing Score: 800 Time Limit: 120 min File Version: 1.0 NS0-507 NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP Exam A QUESTION 1 You are asked to create a
More informationNETAPP - Accelerated NCDA Boot Camp Data ONTAP 7-Mode
NETAPP - Accelerated NCDA Boot Camp Data ONTAP 7-Mode Duration: 5 Days Course Price: $5,850 Course Description Course Overview This training course is a 5-day boot camp with extended hours. The training
More informationNS0-511 netapp. Number: NS0-511 Passing Score: 800 Time Limit: 120 min.
NS0-511 netapp Number: NS0-511 Passing Score: 800 Time Limit: 120 min Exam A QUESTION 1 A customer wants to maintain a single copy for both disaster recovery and backup on a secondary system. Which SnapMirror
More informationNS0-171.network appliance
NS0-171.network appliance Number: NS0-171 Passing Score: 800 Time Limit: 120 min Exam A QUESTION 1 An administrator is deploying a FlexPod solution for use with VMware vsphere 6.0. The storage environment
More informationSnapMirror Configuration and Best Practices Guide for Clustered Data ONTAP
Technical Report SnapMirror Configuration and Best Practices Guide for Clustered Data ONTAP Amit Prakash Sawant, NetApp December 2013 TR-4015 SnapMirror Configuration and Best Practices This document describes
More informationNS0-145 netapp
NS0-145 netapp Number: NS0-145 Passing Score: 800 Time Limit: 120 min Exam A QUESTION 1 To automatically export volumes and directories on reboot, include them in the /etc/exports file. A. True B. False
More informationSMB/CIFS Configuration Guide for Microsoft Hyper-V and SQL Server
ONTAP 9 SMB/CIFS Configuration Guide for Microsoft Hyper-V and SQL Server November 2017 215-11158_E0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this
More informationNetApp Clustered Data ONTAP 8.2
Technical Report NetApp Clustered Data ONTAP 8.2 An Introduction Charlotte Brooks, NetApp May 2013 TR-3982 Abstract This technical report is an introduction to the architecture and key customer benefits
More informationAccelerated NCDA Boot Camp Data ONTAP 7-Mode (ANCDABC87)
Accelerated NCDA Boot Camp Data ONTAP 7-Mode (ANCDABC87) COURSE OVERVIEW: This is a 5-day bootcamp that expands upon what students learned in the D7ADM course in order to prepare for the NCDA 7-mode certification
More informationData ONTAP 8.1 Upgrade and Revert/Downgrade Guide for 7-Mode
IBM System Storage N series Data ONTAP 8.1 Upgrade and Revert/Downgrade Guide for 7-Mode GA32-1034-03 Contents Preface................................ 1 About this guide..............................
More informationOnCommand System Manager 3.1.1
OnCommand System Manager 3.1.1 Managing Clustered Data ONTAP Using the GUI Printable Online Help NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501
More informationOnCommand System Manager 3.1.2
OnCommand System Manager 3.1.2 Managing Clustered Data ONTAP Using the GUI Printable Online Help NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501
More informationClustered Data ONTAP Release Notes
IBM System Storage N series Clustered Data ONTAP 8.2.3 Release Notes SC27-6290-05 Contents Clustered Data ONTAP 8.2.3 Release Notes.................... 1 Changes introduced since Data ONTAP 8.2....................
More informationNetapp Exam NS0-155 Data ONTAP 7-Mode Administrator Version: 6.2 [ Total Questions: 173 ]
s@lm@n Netapp Exam NS0-155 Data ONTAP 7-Mode Administrator Version: 6.2 [ Total Questions: 173 ] Question No : 1 Which command is used to set the configuration of an Ethernet network interface? A. ifconfig
More informationCopy-Based Transition Guide
7-Mode Transition Tool 3.2 Copy-Based Transition Guide For Transitioning to ONTAP February 2017 215-11978-A0 doccomments@netapp.com Table of Contents 3 Contents Transition overview... 6 Copy-based transition
More informationData ONTAP 7-Mode Administration Course D7ADM; 5 Days, Instructor-led
Data ONTAP 7-Mode Administration Course D7ADM; 5 Days, Instructor-led Course Description Welcome to the NetApp Data ONTAP 7-Mode Administration course. Data ONTAP 8 is the next generation data storage
More informationNetApp NS0-511 Exam. Volume: 65 Questions
Volume: 65 Questions Question No: 1 You are creating a SnapMirror relationship and custom SnapMirror policies are not defined. Which default policy will be applied in this scenario? A. MirrorAndVault B.
More informationAccelerated NCDA Boot Camp Data ONTAP 7-Mode Course ANCDABC87; 5 Days, Instructor-led
Accelerated NCDA Boot Camp Data ONTAP 7-Mode Course ANCDABC87; 5 Days, Instructor-led Course Description Prepare for success when taking the NS0-155 NetApp Certified Data Management 7-Mode Administrator
More informationA Thorough Introduction to 64-Bit Aggregates
Technical Report A Thorough Introduction to 64-Bit Aggregates Shree Reddy, NetApp September 2011 TR-3786 CREATING AND MANAGING LARGER-SIZED AGGREGATES The NetApp Data ONTAP 8.0 operating system operating
More informationData ONTAP 8.1 System Administration Guide for Cluster-Mode
Data ONTAP 8.1 System Administration Guide for Cluster-Mode NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 USA Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277
More informationClustered Data ONTAP 8.2 High-Availability Configuration Guide
IBM System Storage N series Clustered Data ONTAP 8.2 High-Availability Configuration Guide SC27-6276-02 Table of Contents 3 Contents Preface... 7 About this guide... 7 Supported features... 7 Websites...
More informationCluster Management Using OnCommand System Manager
ONTAP 9 Cluster Management Using OnCommand System Manager November 2017 215-12668_A0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Understanding System Manager... 15 Icons
More informationCopy-Free Transition Guide
7-Mode Transition Tool 3.0 Copy-Free Transition Guide For Transitioning to ONTAP September 2016 215-11373_B0 doccomments@netapp.com Table of Contents 3 Contents Transition overview... 6 Copy-free transition
More informationThis course is intended for those who provide basic support for and perform administrative functions of the Data ONTAP operating system.
Accelerated NCDA Boot Camp Data ONTAP 8.0 7-Mode (ANCDABC87) Who should attend This course is intended for those who provide basic support for and perform administrative functions of the Data ONTAP operating
More information7-Mode Transition Tool 2.2
7-Mode Transition Tool 2.2 Copy-Based Transition Guide For Transitioning to Clustered Data ONTAP NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501
More informationCluster Expansion Express Guide
ONTAP 9 Cluster Expansion Express Guide June 2017 215-11193-E0 doccomments@netapp.com Updated for ONTAP 9.2 Table of Contents 3 Contents Deciding whether to use this guide... 4 Cluster expansion workflow...
More informationNS Number: NS0-158 Passing Score: 800 Time Limit: 120 min File Version: NS0-158
NS0-158 Number: NS0-158 Passing Score: 800 Time Limit: 120 min File Version: 1.0 NS0-158 NetApp Certified Data Administrator, ONTAP Version 1.0 Экзамен A QUESTION 1 Click the Exhibit button. You create
More informationONTAP 9.3 Cluster Administration and Data Protection Bundle (CDOTDP9)
ONTAP 9.3 Cluster Administration and Data Protection Bundle (CDOTDP9) COURSE OVERVIEW: This 5-day course comprises the 3-day ONTAP 9.3 Cluster Administration (ONTAP9ADM) followed by the 2-day ONTAP 9.3
More informationA Thorough Introduction to 64-Bit Aggregates
TECHNICAL REPORT A Thorough Introduction to 64-Bit egates Uday Boppana, NetApp March 2010 TR-3786 CREATING AND MANAGING LARGER-SIZED AGGREGATES NetApp Data ONTAP 8.0 7-Mode supports a new aggregate type
More informationHitachi HH Hitachi Data Systems Storage Architect-Hitachi NAS Platform.
Hitachi HH0-450 Hitachi Data Systems Storage Architect-Hitachi NAS Platform http://killexams.com/exam-detail/hh0-450 QUESTION: 104 You are asked to design a Hitachi NAS Platform solution with a requirement
More information7-Mode Data Transition Using SnapMirror
Clustered Data ONTAP 8.3 7-Mode Data Transition Using SnapMirror February 2016 215-10873_A0 doccomments@netapp.com Updated for 8.3.2 Table of Contents 3 Contents Transitioning 7-Mode volumes using SnapMirror...
More informationData ONTAP 8.2. MultiStore Management Guide For 7-Mode. Updated for NetApp, Inc. 495 East Java Drive Sunnyvale, CA U.S.
Updated for 8.2.2 Data ONTAP 8.2 MultiStore Management Guide For 7-Mode NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone:
More information7-Mode Data Transition Using SnapMirror Technology
ONTAP 9 7-Mode Data Transition Using SnapMirror Technology September 2016 215-11153_B0 doccomments@netapp.com Visit the new ONTAP 9 Documentation Center: docs.netapp.com/ontap-9/index.jsp Table of Contents
More informationData ONTAP 8.2 Upgrade and Revert/Downgrade Guide For 7-Mode
IBM System Storage N series Data ONTAP 8.2 Upgrade and Revert/Downgrade Guide For 7-Mode SC27-5925-03 Contents Preface................................ vii About this guide.............................
More information64-Bit Aggregates. Overview and Best Practices. Abstract. Data Classification. Technical Report. GV Govindasamy, NetApp April 2015 TR-3978
Technical Report 64-Bit Aggregates Overview and Best Practices GV Govindasamy, NetApp April 2015 TR-3978 Abstract Earlier releases of NetApp Data ONTAP used data block pointers in 32-bit format which limited
More informationSnapDrive for UNIX
SnapDrive 5.2.1 for UNIX Installation and Administration Guide For Linux NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone:
More informationNetworkAppliance NS NetApp Certified Data Administrator, ONTAP.
NetworkAppliance NS0-158 NetApp Certified Data Administrator, ONTAP http://killexams.com/pass4sure/exam-detail/ns0-158 Question: 67 What is the minimum number of disks required to create a data aggregate
More informationClustered Data ONTAP 8.3
Clustered Data ONTAP 8.3 Volume Disaster Recovery Preparation Express Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone:
More informationVolume Disaster Recovery Express Guide
ONTAP 9 Volume Disaster Recovery Express Guide December 2017 215-11188_E0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 Volume disaster
More informationUpgrade and Revert/Downgrade Guide
ONTAP 9 Upgrade and Revert/Downgrade Guide November 2018 215-11143_K0 doccomments@netapp.com Updated for ONTAP 9.5 Table of Contents 3 Contents Deciding whether to use this guide... 5 When to revert and
More informationNetapp Exam NS0-506 NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP Version: 6.0 [ Total Questions: 65 ]
s@lm@n Netapp Exam NS0-506 NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP Version: 6.0 [ Total Questions: 65 ] https://certkill.com Netapp NS0-506 : Practice Test Question No : 1
More informationData Protection Guide
SnapCenter Software 4.0 Data Protection Guide For VMs and Datastores using the SnapCenter Plug-in for VMware vsphere March 2018 215-12931_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding
More informationOnCommand System Manager 3.1 RC1 Release Notes for Clustered Data ONTAP
IBM System Storage N series OnCommand System Manager 3.1 RC1 Release Notes for Clustered Data ONTAP SC27-6427-01 Contents System Manager 3.1 RC1 Release Notes...................... 1 Understanding System
More informationData Fabric Solution for Cloud Backup Workflow Guide
Data Fabric Solutions Data Fabric Solution for Cloud Backup Workflow Guide Using ONTAP, SnapCenter, and AltaVault June 2017 215-11811_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether
More informationData ONTAP 8.2. System Administration Guide For 7-Mode. Updated for NetApp, Inc. 495 East Java Drive Sunnyvale, CA U.S.
Updated for 8.2.1 Data ONTAP 8.2 System Administration Guide For 7-Mode NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone:
More informationData ONTAP Release Notes
IBM System Storage N series Data ONTAP 7.3.7 Release Notes GC53-1175-25 Contents Data ONTAP 7.3.7 Release Notes....................... 1 About the Data ONTAP 7.3.7 release....................... 1 About
More informationDeep Dive - Veeam Backup & Replication with NetApp Storage Snapshots
Deep Dive - Veeam Backup & Replication with NetApp Storage Snapshots Luca Dell Oca EMEA Evangelist, Product Strategy Specialist for Veeam Software, VMware vexpert, VCAP-DCD, CISSP Modern Data Protection
More informationSAP with Microsoft SQL Server on Windows
o Technical Report SAP with Microsoft SQL Server on Windows Best Practices Using NetApp Clustered Data ONTAP and SnapCenter Marco Schoen, NetApp November 2015 TR-4467 Abstract This document provides customers
More informationData ONTAP 8.2. Upgrade and Revert/Downgrade Guide For 7-Mode. Updated for NetApp, Inc. 495 East Java Drive Sunnyvale, CA U.S.
Updated for 8.2.2 Data ONTAP 8.2 Upgrade and Revert/Downgrade Guide For 7-Mode NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone:
More informationNDMP in Clustered Data ONTAP for Tape Backup Software Applications
Technical Report NDMP in Clustered Data ONTAP for Tape Backup Software Applications Subhash Athri, NetApp June 2015 TR-4376 TABLE OF CONTENTS 1 NDMP Backups... 3 1.1 Tape Backup Topologies in Clustered
More informationData ONTAP Mode Release Notes
IBM System Storage N series Data ONTAP 8.0.4 7-Mode Release Notes GA32-0723-15 Contents Data ONTAP 8.0.4 7-Mode Release Notes.................... 1 Changes introduced since Data ONTAP 8.0....................
More informationClustered Data ONTAP 8.3 Update 2, IPspaces. Self-paced Lab NETAPP UNIVERSITY. NetApp University - Do Not Distribute
NETAPP UNIVERSITY Clustered Data ONTAP 8.3 Update 2, IPspaces Self-paced Lab Course ID: STRSW-SPL-CDOT83UPD2 Content Version: 1.0 ATTENTION The information contained in this course is intended only for
More informationSnapDrive 6.5 for Windows for Clustered Data ONTAP: Best Practices Guide
Technical Report SnapDrive 6.5 for Windows for Clustered Data ONTAP: Best Practices Guide Santhosh Harihara Rao, NetApp January 2013 TR-4000 Abstract This technical report provides guidelines and best
More informationClustered Data ONTAP 8.2
Updated for 8.2.1 Clustered Data ONTAP 8.2 7-Mode Data Transition Using SnapMirror NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support
More informationITdumpsFree. Get free valid exam dumps and pass your exam test with confidence
ITdumpsFree http://www.itdumpsfree.com Get free valid exam dumps and pass your exam test with confidence Exam : NS0-180 Title : NetApp Certified Storage Installation Engineer, Clustered Data ONTAP Vendor
More informationExam Questions NS0-180
Exam Questions NS0-180 NetApp Certified Storage Installation Engineer, Clustered Data ONTAP https://www.2passeasy.com/dumps/ns0-180/ 1. Which three types of interface groups are supported on NetApp storage
More informationOnCommand System Manager Release Notes for Clustered Data ONTAP
IBM System Storage N series OnCommand System Manager 3.1.2 Release Notes for Clustered Data ONTAP SC27-6427-04 Contents System Manager Release Notes........................ 1 Understanding System Manager........................
More informationVirtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere
Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Workflow Guide for 7.2 release July 2018 215-13170_B0 doccomments@netapp.com Table of Contents 3 Contents Deciding
More informationClustered Data ONTAP 8.2
Clustered Data ONTAP 8.2 SAN Express Setup Guide for 62xx Systems NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1(408) 822-6000 Fax: +1(408) 822-4501 Support telephone: +1 (888)
More informationManaging Data ONTAP Operating in 7-Mode Using the GUI
OnCommand System Manager 3.1.3 Managing Data ONTAP Operating in 7-Mode Using the GUI Printable Online Help July 2017 215-11900_A0 doccomments@netapp.com Table of Contents 3 Contents Welcome to OnCommand
More informationData ONTAP 7-Mode Administration
Data ONTAP 7-Mode Administration Cursusduur: 5 Dagen Cursuscode: D7ADM Beschrijving: This five-day instructor-led course enables you to perform basic support and administrative functions on a NetApp storage
More informationClustered Data ONTAP 8.2 Software Setup Guide
IBM System Storage N series Clustered Data ONTAP 8.2 Software Setup Guide SC27-6282-02 Table of Contents 3 Contents Preface... 5 About this guide... 5 Supported features... 5 Websites... 6 Getting information,
More informationActual4Test. Actual4test - actual test exam dumps-pass for IT exams
Actual4Test http://www.actual4test.com Actual4test - actual test exam dumps-pass for IT exams Exam : NS0-158 Title : NetApp Certified Data Administrator, ONTAP Vendor : Network Appliance Version : DEMO
More informationIT Certification Exams Provider! Weofferfreeupdateserviceforoneyear! h ps://www.certqueen.com
IT Certification Exams Provider! Weofferfreeupdateserviceforoneyear! h ps://www.certqueen.com Exam : NS0-102 Title : NetApp(ASAP) Accredited Storage Architect Professional Version : DEMO 1 / 7 1. Which
More informationEMC Exam E VNX Solutions Specialist Exam for Implementation Engineers Version: 9.0 [ Total Questions: 411 ]
s@lm@n EMC Exam E20-390 VNX Solutions Specialist Exam for Implementation Engineers Version: 9.0 [ Total Questions: 411 ] Topic 3, Volume C Question No : 1 - (Topic 3) A customer has an application that
More informationSnapDrive 5.3 for UNIX
SnapDrive 5.3 for UNIX Administration Guide for Linux NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277
More informationNetwork Management Guide
ONTAP 9 Network Management Guide November 2017 215-11141_E0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 7 Networking components of a
More informationOnCommand Cloud Manager 3.2 Deploying and Managing ONTAP Cloud Systems
OnCommand Cloud Manager 3.2 Deploying and Managing ONTAP Cloud Systems April 2017 215-12035_C0 doccomments@netapp.com Table of Contents 3 Contents Before you create ONTAP Cloud systems... 5 Logging in
More informationVendor: IBM. Exam Code: Exam Name: IBM Midrange Storage Technical Support V3. Version: Demo
Vendor: IBM Exam Code: 000-451 Exam Name: IBM Midrange Storage Technical Support V3 Version: Demo QUESTION NO: 1 On the Storwize V7000, which IBM utility analyzes the expected compression savings for an
More informationAbstract. Data Classification. Technical Report. Roy Scaife, NetApp Version March 2016 TR-4375
Technical Report Roy Scaife, NetApp Version 1.2.1 March 2016 TR-4375 Abstract This document provides technical information about NetApp MetroCluster software in the NetApp Data ONTAP 8.3.2 operating system.
More informationOffloaded Data Transfers (ODX) Virtual Fibre Channel for Hyper-V. Application storage support through SMB 3.0. Storage Spaces
2 ALWAYS ON, ENTERPRISE-CLASS FEATURES ON LESS EXPENSIVE HARDWARE ALWAYS UP SERVICES IMPROVED PERFORMANCE AND MORE CHOICE THROUGH INDUSTRY INNOVATION Storage Spaces Application storage support through
More informationSAN Administration Guide
ONTAP 9 SAN Administration Guide November 2017 215-11147_E0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 7 Understanding SAN host provisioning...
More informationOnCommand System Manager 3.1.1
OnCommand System Manager 3.1.1 Managing Data ONTAP Operating in 7-Mode Using the GUI Printable Online Help NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1
More information