Overcoming the Testing Challenges of 40G and Beyond. Eric Farst Channel Sales Manager
|
|
- Raymond Beasley
- 5 years ago
- Views:
Transcription
1 Overcoming the Testing Challenges of 40G and Beyond Eric Farst Channel Sales Manager
2 Agenda Introduction Increased demand for speed & capacity in the Enterprise/Data Center How Enterprises/Data Centers are meeting the demand Fiber Infrastructure Understanding parallel optics & MPO connectivity Updates to fiber test standards MPO test scenarios (10G & beyond) Copper Infrastructure Why copper in today s data centers? Copper (10G & beyond) Testing/certifying copper for Category 8 and 40GBASE-T Summary
3 Introduction
4 Demand for Higher Speeds and More Data! Increased Users Broadband everywhere Increased Access Rates Multiple access schemes, WiFi, FTTH, LTE, WiMAX Increased Services Social media explosion, content on Internet Massive data requirements due to video traffic Google Cisco Visual Networking Index!
5 Google results
6 Can Data Center Supply Keep up with Demand New Server Updates to Physical Technologies Infrastructure Standards 10GBASE-T LAN on Motherboard (LOM) New breed of servers Parallel optics Higher frequency copper cabling Data Center Topologies Move from traditional 3-tier to leaf-spine More virtualization LAN/SAN convergence
7 Fiber Infrastructure
8 Fiber Infrastructure the Move to MPO Achieving 40/100 G on multimode fiber Use of parallel optics through QSFP/CFP transceivers and MPO arrays IEEE 40G BASE-SR4 Mostly multimode preferred for data center applications TIA 942-A requires use of OM3 Fiber 40G needs 8 ports of 12-fiber MPO array 100G needs 20 ports of 24-fiber MPO array (today) Parallel optics already in use for legacy (1/10G) via cassettes
9 What is MPO/MTP? Parallel optics more than one fiber per connector Typically 12, 24, 48 fibers MPO = Multi-Fiber Push On/Pull Off. Generic term MTP = Trademark of US Conec. Specific type of MPO connector Used for: Cable consolidation 12f backbone to: Cassettes for duplex connectivity MPO-LC harness for SAN Directors 40Gig Ethernet 100Gig Ethernet Being installed in data centers and other types of networks Work at 1/10G today with cassettes Simple transition path to 40G 100G also possible
10 Data Center Examples of MPO/Ribbon Fiber 6 1/10Gbps Ethernet Links 12 fiber MPO Link w/cassettes at either end Fiber consolidation and migration path SFP/SPF+ at each end 1/10/40/100Gbps Optical Ethernet Distribution Switching/Routing 4 10Gbps Ethernet Links SAN Switches 1/10/40Gbps Optical Ethernet Access Switching 8 fiber MPO Link w/cassette Fiber consolidation and migration path QSFP at switch SPF+ at server SAN Fiberchannel 1/10 Gbps Electrical/Optical Ethernet 40Gbps Ethernet Link Storage Servers 12 fiber MPO Link (8 fibers used) 12 fiber MPO Link (8 fibers used) QSFP at both ends
11 Ethernet Protocols that Require 40GBASE-SR4 ("short range") Ribbon Fiber A port type for multimode fiber and uses 850 nm lasers. It uses four lanes of multi-mode fiber delivering serialized data at a rate of Gbit/s per lane. Uses Quad Small Form-factor Pluggable (QSFP) hotpluggable transceivers 100GBASE-SR10 ("short range") A port type for multimode fiber and uses 850 nm lasers. It uses ten lanes of multi-mode mode fiber delivering serialized data at a rate of Gbit/s per lane. Uses C Form-factor Pluggable (CFP) The c stands for the Latin letter C used to express the number 100 (centum) 100GBASE-SR4 is being worked on by IEEE 4 lanes each at ~25Gbit/s Text and Image from Wikipedia
12 Polarity and Gender
13 MPO Polarity
14 Update in Fiber Testing Standards Fiber Standards recently updated or in process ISO ISO/IEC TIA TIA Addresses the issue of uncertainty in loss measurements Recommends 3 test cord reference method for channel measurements Recommends 1 test cord reference method for permanent link measurements Requires end-faces be clean in accordance with IEC Requires Encircled Flux test set transmitter launch
15 Specific Testing Issues for 40G Polarity Issues (Ribbon/MPO) Fiber Three types of standard MPO cords in the market, causing a lot of confusion Need for a graphical tool to provide wiremap like features Interoperability between 10G->40G links Most installations use break-out cables/cassettes to get 10G links Test Instrument should be able to support LC on one end and MPO on other Gender Male (w/pins) and female (w/o pins) Test cord gender must match system under test gender Insertion Loss Maximum permissible loss of 1.9 db (40GBASE-SR4 Channel) Connector loss is critical
16 Single Fiber vs. Multi-Fiber Connectors SINGLE FIBER CONNECTOR MULTI-FIBER CONNECTOR White ceramic ferrule Polymer ferrule One fiber per connector Common types include SC, LC, FC, and ST Multiple fibers in linear array (for example, 8, 12, 24, 48, and 72) in single connector providing high-density connectivity Common type is MPO or MTP
17 Anatomy of a 12-fiber Multimode MPO Connector The MPO fiber connector has 4 major areas: Fiber Ferrule Alignment pins/sockets Polarity key Key Fibers Polymer Ferrule Alignment pins/sockets 12 Fiber MultiMode Connector (Female)
18 Focused on the Connection Adapter MPO Male MPO Female
19 Focused on the Connection Physical Contact The Physical Contact area is the critical joining point in the fiber network. If there is not a clean physical connection, the light path is disrupted d and the connection is compromised.
20 Top-view Cross Section 12 Fiber MPO - Clean Physical Contact Example of Clean Connection (no contamination)
21 Top-view Cross Section 12 Fiber MPO Dirty Air Gap Particle Dirt Example of Dirty Connection (contamination causing air gaps, back reflection, insertion loss) Dirt Back Reflection Insertion Loss 12
22 Inspect Before You Connect sm Follow this simple INSPECT BEFORE YOU CONNECT process to ensure fiber end faces are clean prior to mating connectors.
23 IEC Sets Requirements for Connector Quality Even for MPO! CLADDING Zone CORE Zone Multimode MPO Connectors
24 Inspect and Clean Both Connectors in Pair! Inspecting BOTH sides of the connection is the ONLY WAY to ensure that it will be free of contamination and defects. Patch Cord ( Male ) Inspection Bulkhead ( Female ) Inspection Patch cords are easy to access and view compared to the fiber inside the bulkhead, which is frequently overlooked. The bulkhead side may only be half of the connection, but it is far more likely to be dirty and problematic.
25 Inspect ALL fibers in a Multi-Fiber Connector!
26 What Other Tests Need to be Polarity Checks Performed? Type A cord Type B adapter Type B cord =???!!! Test from MPO to simplex (SC/LC) Insertion loss measurement Need to be able to perform reference Loss per fiber with Pass/Fail Power measurements on live systems
27 Check Polarity for Fiber Map For existing installations, i the endto-end polarity is often not known Fiber Map shows the polarity of the system or trunk
28 Test Scenario 1: MPO to MPO MPO Bulkhead MPO Trunk MPO Bulkhead MPO Test Reference Cords Tester with MPO RX Tester with MPO TX Easiest way to test Test permanent link trunks Test 40G channels Ensure polarity and loss
29 Test Scenario 2: MPO to Single Fiber MPO Cassette MPO Trunk MPO Bulkhead Tester with MMF RX MMF Test Reference Cord MPO Test Reference Cord Tester with MPO TX One end MPO source Other end simplex power meter Testing from MPO to Fanouts or Cassettes End-to-end trunks for 10G to QSFP Fiber Map from MPO to LC/SC
30 Test Scenario 3: Any Source to MPO MPO Bulkhead MPO Trunk Bulkhead Tester with MPO RX MPO Test Reference Cord Any Source One end MPO power meter Other end any source Fault isolation Testing output power from 40G optics
31 Test Scenario 4: 100G Testing Using Array Testing 24 fiber MPO Trunks Use Array or Y cable 24 fiber MPO to 2x 12 fiber MPO 100Gbps Ethernet Link 20 fiber MPO Link CXP at both ends
32 Test Scenario 5: Selected Channels Can apply to any of the above scenarios Allows selection of which of the 12 channels are active At the Remote (TX) and at the Local (RX) Helps in cases when 8 or fewer fibers are present in MPO links (40GBASE- SR4) Results reflect topology No unwanted fails due to nonexistent channels
33 Things to Remember for Loss Reference first! Measurements Connector gender may require three cord reference test method Three cord reference test method is recommended for channel testing (plugs at both ends) Check the reference! Set limit Network or Custom (db) Auto-Test Makes it Easy!
34 Auto-Test Results Loss and Fiber Map
35 Copper Infrastructure
36 Why Does Anyone Want Copper in the Data Center? Backwards compatible with other BASE-T technologies Auto-negotiate Migration path vs. forklift upgrade Potentially cheaper than fiber Installation Maintenance Uses a well-known and understood media Category 6A for 10GBASE-T Power over Ethernet Wireless Access Points
37 Where is 10GBASE-T Today? Major network equipment vendors have added 10GBASE-T switches to their offerings Servers now come with 10GBASE-T on the motherboard Copper has always been the cheapest way to connect servers Energy Efficient Ethernet (EEE) has significantly lowered to power Energy Efficient Ethernet (EEE) has significantly lowered to power requirements and allowed a low-power mode
38 Copper Moving Beyond 10G Achieving 40G in copper is needed because Servers of the future will require this speed of connectivity Large datacenters are connecting servers at 40G today using fiber 40G over copper standard does exist today 40GBASE-CR4 < 7m (used within racks) Occupies a lot of space per Gbps compared to BASE-T But most commonly used lengths are between 10 m and 30 m Evolving CAT8/40GBASE-T standards support 30 m (EoR)
39 TIA/IEEE Working Groups TR42.7 is the TIA engineering sub-committee responsible for copper cabling Since Feb 2011 it has been working to develop a new category of cabling to support future applications beyond 10GBASE-T This new category of cabling will be called Category 8 and it will operate up to 2000 GHz A liaison has been established with the IEEE Next Generation BASE-T study group The IEEE has formed a Next Generation BASE-T study group 40GBASE-T (802.3bq) This group is meeting every month to get this standard ratified quickly Preserve existing Ethernet frame structure and min/max frame sizes Auto-Negotiate to lower Ethernet speeds
40 Upcoming Category 8 Standard Likely to be available by 2015 Will allow an RJ45 connector Supports 30m of 40GBASE-T Specified to 2000 MHz Shielded cable required Primarily targeted at Datacenter markets with smaller channel length requirement Many limits are already defined Please note this standard is not ratified yet, but very much on its way.
41 Testing/Certification of Copper Cabling ANSI/TIA/EIA-568-C.2 standard requires that installations be field tested to ensure the cabling system (as installed) meets the performance characteristics of a given category Many cable vendors provide warranties on cable installations only if installations are certified according to these specifications Many customers of cabling contractors insist on documented test results
42 What is Field Tester Accuracy? Defined in ISO/IEC /Ed. 2 TIA 1152 ISO draft Level V is for Class FA (1000 MHz) TIA 1152 Level IIIe is for Category 6A (500 MHz) expect 2000 MHz Level VIII Defines baseline, link and channel accuracy of a field tester in comparison with a network analyzer for various parameters Ensures that cable certifiers are precise with minimal internal noise that would impact actual measurements Typically independent verification of Level V and Level IIIe accuracy is required
43 Certifying Category 8 Frequency of Testing Should be capable of certifying cables up to 2 GHz (at least) Accuracy of Field Tester TIA-1182 Speed of Testing With the increase in frequency test times should not be inordinate Legacy testers take 25 s for CAT 6A (500 MHz)
44 Summary Data consumption has exploded in the past few years Everything in Enterprise/Data Centers is NEW Servers / Topologies / Standards / Infrastructure New fiber infrastructures built around MPO connectivity Supports 1G / 10G / 40G / 100G 40/100G TODAY) Specific Testing Issues (Polarity / Interoperability / Loss Budgets) Inspect Before You Connect Critical for MPO! Copper is at Cat6A for 10Gbps TODAY Moving to higher h categories and dfaster speeds Category 8 (2000MHz) & 40GBASE-T Today s Enterprise/Data Center test tools must be able to: Test BOTH Fiber & Copper Support the latest standards and best practices Test 1G / 10G / 40G / 100G applications
45 Thank-You!
Testing Parallel Optics
White Paper Testing Parallel Optics Author: Ed Gastle VIAVI Solutions To accommodate the relentless need for speed, driven by mobile devices, watching videos online and uploading and sharing content, network
More informationPARALLEL OPTICS CLEANING AND TESTING JANUARY 2018 FOR PROFESSIONALS MANAGING THE CABLE AND WIRELESS SYSTEMS THAT ENABLE CRITICAL COMMUNICATIONS DESIGN
JANUARY 2018 FOR PROFESSIONALS MANAGING THE CABLE AND WIRELESS SYSTEMS THAT ENABLE CRITICAL COMMUNICATIONS CLEANING AND TESTING PARALLEL OPTICS DESIGN PAGE 5 Single pair Ethernet: Data and power DATA CENTER
More informationTesting Considerations for Beyond 10Gigabit Ethernet. Erin Hallett
Testing Considerations for Beyond 10Gigabit Ethernet Erin Hallett JDSU Agenda Intro Need for Speed Growth of IP traffic Fiber vs. Copper Fiber Tightening requirements Testing considerations and practices
More informationTrends in Testing Data Center Infrastructure. Ed Gastle VIAVI Solutions
Trends in Testing Data Center Infrastructure Ed Gastle VIAVI Solutions Agenda INTRODUCTION Modern Data Center Architecture Historically Enterprise has been a 3 tier topology Core, Aggregation, Access Cloud
More informationAre Conflicts in Data Center Fiber Optic Structured Cabling Standards Putting Your Organization at Risk?
Are Conflicts in Data Center Fiber Optic Structured Cabling Standards Putting Your Organization at Risk? Rick Dallmann Senior Data Center Infrastructure Architect CABLExpress 36 Years of Experience CABLExpress
More informationThe Impact of Emerging Data Rates on Layer One Fiber Cabling Infrastructures. Rick Dallmann Senior Data Center Infrastructure Architect CABLExpress
The Impact of Emerging Data Rates on Layer One Fiber Cabling Infrastructures Rick Dallmann Senior Data Center Infrastructure Architect CABLExpress 36 Years of Experience CABLExpress is a manufacturer of
More informationHIGH DENSITY DATA CENTER CABLING GUIDE. Optics DACs Cables Cable Management Fiber TAPs Media Converters
HIGH DENSITY DATA CENTER CABLING GUIDE Optics DACs Cables Cable Management Fiber TAPs Media Converters PROVIDING MTP CABLING SOLUTIONS FOR THE SMART DATA CENTER. APPROVED NETWORKS SETS THE STANDARD The
More informationFiber in Data Centers What s Next? Srinivasan B, RCDD
Fiber in Data Centers What s Next? Srinivasan B, RCDD Hubbell Fiber Systems 10G / 40G / 100G / 400G Standards, Applications and Practices Agenda Part 1: Current Technologies Standards Review IEEE 802.3:
More informationFiber Optic Cabling Systems for High Performance Applications
Fiber Optic Cabling Systems for High Performance Applications BICSI Conference Bangkok, Thailand 17-18 November 2016 Nicholas Yeo, RCDD/NTS/DCDC Data Center Trends Computing evolution Cloud computing Servers
More informationThe Arista Universal transceiver is the first of its kind 40G transceiver that aims at addressing several challenges faced by today s data centers.
ARISTA WHITE PAPER QSFP-40G Universal Transceiver The Arista Universal transceiver is the first of its kind 40G transceiver that aims at addressing several challenges faced by today s data centers. Increased
More informationInsuring 40/100G Performance Multimode Fiber Bandwidth Testing & Array Solutions. Kevin Paschal Sr. Product Manager Enterprise Fiber Solutions
Insuring 40/100G Performance Multimode Fiber Bandwidth Testing & Array Solutions Kevin Paschal Sr. Product Manager Enterprise Fiber Solutions Fiber Optics LAN Section Part of the Telecommunications Industry
More informationDATA CENTER SYMPOSIUM
DATA CENTER SYMPOSIUM Dynamic Changes in Data Center Optic Transmissions & The Impact to Structured Fiber Cabling Rick Dallmann CABLExpress Years of Experience CABLExpress is a manufacturer of custom built
More informationCategory 8 paves the way for IEEE 40GBASE-T. David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope
Category 8 paves the way for IEEE 40GBASE-T David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope Agenda Market need for 40 G over balanced twisted pair cabling Standards ISO/IEC 11801-99-1
More informationMTP/MPO SOLUTIONS FIBERTRONICS. General Applications & Loss Specifications
MTP/MPO SOLUTIONS FIBERTRONICS Multifiber Push-On (MPO) connectors have answered the call for more bandwidth and more space efficiency. MPO connectors are able to provide up to 24 or more fibers in a single
More informationPREPARING FOR FUTURE STRUCTURED CABLING REQUIREMENTS IN THE DATA CENTER: 40/100 GIGABIT ETHERNET AND BEYOND
PREPARING FOR FUTURE STRUCTURED CABLING REQUIREMENTS IN THE DATA CENTER: 40/100 GIGABIT ETHERNET AND BEYOND Cindy Montstream, RCDD/NTS, EE, CPLP Director of elearning and Standards DATA COMMUNICATIONS
More informationKeeping up to Speed with High Data Rate Fiber Solutions. Eric Leichter Manager, Training and Technology
Keeping up to Speed with High Data Rate Fiber Solutions Eric Leichter Manager, Training and Technology Keeping up to Speed with High Data Rate Fiber Solutions Global Standards Update OM4 Optical Fiber
More informationCisco 100GBASE QSFP-100G Modules
Data Sheet Cisco 100GBASE QSFP-100G Modules Product Overview The Cisco 100GBASE Quad Small Form-Factor Pluggable (QSFP) portfolio offers customers a wide variety of high-density and low-power 100 Gigabit
More informationCopper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only
1 Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only Gautier Humbert, RCDD Standards Coordinator Digital Infrastructures Legrand District Chair Mainland Europe BICSI 2 Agenda
More informationCabling Solutions for Nexus 9000 Switches With Dual-Rate 40/100G BiDi Transceiver and Panduit Connectivity
Cabling Solutions for Nexus 9000 Switches With Dual-Rate 40/100G BiDi Transceiver and Panduit Connectivity Introduction Virtualization and cloud technologies have applied an incredible amount of pressure
More informationMTP Multi Lite Trunk Assemblies
MTP Multi Lite Trunk Assemblies MTP Multi-Lite Trunk assemblies are a neat solution for providing up to four MTP -MTP links within a compact, high density ruggedised cable. The cable construction consists
More informationFiber Backbone Cabling in Buildings
White Paper Fiber Backbone Cabling in Buildings www.commscope.com Contents Introduction 3 Backbone Cabling Speeds 3 Optical Fiber in the Backbone 4 b/s Optical Fiber Backbone 4 Migrating to 40 Gbps and
More informationChoosing MPO Connectors for the Data Center. Ken Hall, RCDD, NTS Data Center Architect CommScope
Choosing MPO Connectors for the Data Center Ken Hall, RCDD, NTS Data Center Architect CommScope Agenda Network Architecture changes Data Center & MPO Standards Application comparisons Additional considerations
More informationCorning Distance and Link-Loss Budgets for the Cisco 40GbE BiDi Transceiver
9 0 Corning Distance and Link-Loss Budgets for the Cisco 0GbE BiDi Transceiver This paper discusses the following topics for the Cisco bidirectional (BiDi) transceiver: Cisco quad small-form-factor pluggable
More informationData Center: First-Time Right Acceptance Testing Steps for Certification and Troubleshooting - Intra & Inter-connect. Nicholas Gagnon EXFO
Data Center: First-Time Right Acceptance Testing Steps for Certification and Troubleshooting - Intra & Inter-connect Nicholas Gagnon EXFO Data Center today Source: EXFO Global Data Center Traffic by Destination
More informationAnticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards
Anticipating Cat 8 Agenda Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards What is Cat 8? Next Generation Copper Cabling 25G and 40G data rates over twisted pair copper
More informationTrends in Data Centre
Trends in Data Centre The impact on the IT infrastructure Thomas Ko Product Manager Market Situation Standards Update and Topology 40G and 100G Ethernet - Impact on IT Cabling Migration Options with Fiber
More informationSimplify Fiber Optic Cabling Migrations with a Multi-Path System
Simplify Fiber Optic Cabling Migrations with a Multi-Path System By Dave Fredricks, Data Center Infrastructure Architect, CABLExpress and Rick Dallmann, Sr. Data Center Infrastructure Architect, CABLExpress
More informationAdvances in Fiber Tier 2 Enterprise & Data Center Testing
Advances in Fiber Tier 2 Enterprise & Data Center Testing As the volume of fibers deployed into enterprise increases significantly, fiber cabling advances like multi-fiber (MPO) connectors and interfaces
More informationFTTE Revisited for New Technologies
FTTE Revisited for New Technologies A new look into FTTE design to allow great flexibility as well as compliance to the latest 40G and 100G. Gautier Humbert, RCDD, CDCDP Business Development Manager Eastern
More informationPlug & Play Universal Low-Loss Systems A LANscape Pretium Solutions Product
Applications Data Center LAN/SAN Enterprise Building Backbone -to-the-desk Description Plug & Play Universal Systems are preterminated optical fiber cabling systems designed to dramatically improve performance
More informationDC Center Copper Cabling up to 40Gbase-T. Halim Senjaya
DC Center Copper Cabling up to 40Gbase-T Halim Senjaya CTDC CTIA Data Center Expert Datwyler Singapore Diploma in Eng ng in Physics Bandung IT Diploma in Cloud DC Technologies - NP MBA Middlebury Institute
More informationConflicts in Data Center Fiber Structured Cabling Standards
Conflicts in Data Center Fiber Structured Cabling Standards By Dave Fredricks, CABLExpress Data Center Infrastructure Architect Various telecommunications and data center (DC)-specific standards are commonly
More informationA Fork in the Road OM5 vs. Single-Mode in the Data Center. Gary Bernstein, Sr. Director, Product Management, Network Solutions
A Fork in the Road OM5 vs. Single-Mode in the Data Center Gary Bernstein, Sr. Director, Product Management, Network Solutions Outline Definition of Enterprise and Cloud Data Centers The Growth of Cloud
More informationNGBASE-T Cabling Requirements
NGBASE-T Cabling Requirements Dr. T. C. Tan, DMTS, CommScope Labs B.Sc (Eng), DIC, PhD, CEng, FIET White paper www.commscope.com Contents Contents Contents 2 1.0 Introduction 3 2.0 IEEE 802.3 NGBASE-T
More informationPluggable Transceivers Industry standard Pluggable Transceivers and Direct Attach Cables
DATASHEET Pluggable Transceivers Industry standard Pluggable Transceivers and Direct Attach Cables Product Overview Modular Ethernet interfaces from 100Mbps to 40Gbps Support for a large variety of cable
More informationSolutions FOR DATA CENTERS AND STORAGE AREA NETWORKS
Solutions FOR DATA CENTERS AND STORAGE AREA NETWORKS Xtreme12 is Opticonx s Base-12 cabling solution for easy migration of 10/25/40/50/100 and 400G parallel optics deployments in the data center. This
More informationExtremeSwitching TM. 100Gb Ethernet QSFP28 Transceivers and Cables. Product Overview. Data Sheet. Highlights. 100Gb Ethernet QSFP28 SR4 MMF
Data Sheet Highlights Compact Quad Small Form-factor Pluggable (QSFP28) products for high density 100Gb Ethernet applications Hot swappable, field serviceable modular interfaces for Extreme Networks switches
More informationTESTING HIGH SPEED FIBER LINKS
TESTING HIGH SPEED FIBER LINKS Rodney Casteel, RCDD, DCDC, NTS, OSP - CommScope, Chair TIA FOTC Tyler Vander Ploeg, RCDD - Viavi Solutions Jamie Humphreys - EXFO Rob Gilberti - AFL Jim Davis - Fluke Networks
More informationArista 400G Transceivers and Cables: Q&A
Arista 400G Transceivers and Cables: Q&A What are the benefits of moving to 400G technology? 400G Transceivers and Cables Q&A Arista s 400G platforms allow data centers and high-performance computing environments
More informationLAN Standards, News & Trends Update 2017 June 15, 2017
LAN Standards, News & Trends Update 2017 June 15, 2017 Greg Olson Jtech Systems, Inc Infrastructure Specialist Greg@jtechreps.com 425-437-1962 Our Objectives Review new & ongoing applications work in IEEE
More informationOptics Modules and Cables Data Sheet
Key Features Deployment flexibility of 100GbE, 40GbE, 10GbE or 1GbE modules Smallest and lowest power 10GbE optic module form factor Hot swappable to maximize uptime and simplify serviceability SFP+ Optical
More informationAre you Ready for 40G and 100G?
White Paper Are you Ready for 40G and 100G? 12- vs. 24-fiber MTP cabling for higher-speed Ethernet Gary Bernstein, RCDD Director of Product Management Fiber and Data Center Leviton Network Solutions Abstract
More informationHow to Decide on Optical Fibre Termination Options. Thomas Ko, RCDD Product Manager Tyco Electronics / AMP NetConnect
How to Decide on Optical Fibre Termination Options Thomas Ko, RCDD Product Manager Tyco Electronics / AMP NetConnect Termination Choices Optical Fiber Cabling in Data Center Options available Traditional
More informationFAS-NET MPO Solution. Benefits of FAS-NET MPO Fiber Optic Solution:
Stable and Reliable Data Communication Solutions from Infinique Infinique has designed and developed quality product with affordable pricing for communication infrastructure solutions. This position has
More informationHigh Speed Migration: Choosing the right multimode multi-fiber push on (MPO) system for your data center
High Speed Migration: Choosing the right multimode multi-fiber push on (MPO) system for your data center Table of Contents Introduction 3 Figure 1 - The Ethernet road map 3 Planning considerations 4 Fiber
More informationCisco 100GBASE QSFP-100G Modules
Data Sheet Cisco 100GBASE QSFP-100G Modules Product Overview The Cisco 100GBASE Quad Small Form-Factor Pluggable (QSFP) portfolio offers customers a wide variety of high-density and low-power 100 Gigabit
More informationCisco 40GBASE QSFP Modules
Data Sheet Cisco 40GBASE QSFP Modules Product Overview The Cisco 40GBASE QSFP (Quad Small Form-Factor Pluggable) portfolio offers customers a wide variety of high-density and low-power 40 Gigabit Ethernet
More informationOptical Fiber Networks: Industry. and New Options for Networks
Optical Fiber Networks: Industry Trends, Application Influences and New Options for Networks Herbert V Congdon II, PE Manager, Standards & Technology Tyco Electronics AMP NETCONNECT Solutions Preview Deciding
More informationHistory of Standards
History of Standards From 10Mbps to 100Gbps Ethernet 12 th May 2014 Gautier Humbert, RCDD Business Development Manager Legrand East and Central Europe Agenda 1- Current standards and their structures
More informationWideband Multimode Fiber What is it and why does it make sense?
White Paper Wideband Multimode Fiber What is it and why does it make sense? March, 2015 Contents Executive summary 3 A brief history of MMF 3 The role of fiber connectors 4 Introducing WBMMF 5 2 Executive
More informationOptics Modules and Cables Data Sheet
Optics Modules and Cables Data Sheet Key Features Deployment flexibility of 100GbE, 40GbE, 25GbE, 10GbE or 1GbE modules Smallest and lowest power SFP optic module form factor for 1GbE, 10GbE and 25GbE
More informationData Center & Cloud Computing Infrastructure Solutions DATASHEET. MTP/MPO-LC/SC Cassette High-density Pre-terminated Modular Cassette System
Data Center & Cloud Computing Infrastructure Solutions DATASHEET MTP/MPO-LC/SC Cassette High-density Pre-terminated Modular Cassette System REV.1.0 2018 MTP MPO Cassette 01 Description FS.COM Fiber Optic
More informationClause 86 MDI Optical Pin Layout and Connector. Paul Kolesar, CommScope Sharon Lutz, USConec IEEE P802.3ba January 2009
Clause 86 MDI Optical Pin Layout and Connector Paul Kolesar, CommScope Sharon Lutz, USConec IEEE P802.3ba January 2009 Outline MPO connector standards MDI Pin Layout Cabling Polarity Compatibility Rationale
More informationFiber backbone cabling in buildings
White paper Fiber backbone cabling in buildings www.commscope.com 1 Contents Introduction 3 Backbone cabling speeds 3 Optical fiber in the backbone 3 10 Gbps optical fiber backbone 3 Migrating to 40 Gbps
More informationTim Takala RCDD. Vice President Field Application Engineer APAC. Mobility is Driving Changing Network Architectures & Transceiver Evolutions
Tim Takala RCDD Vice President Field Application Engineer APAC Mobility is Driving Changing Network Architectures & Transceiver Evolutions 5TOP TRENDS SHAPING NETWORKS 1. Mobility 2. Connected Devices
More informationIntra-DC & DCI considerations for 100G+ migration
Intra-DC & DCI considerations for 100G+ migration Nicholas Gagnon, BDM Data Center NANOG 68 Dallas - October 18 th, 2016 2015 EXFO Inc. All rights reserved. 1 10G/40G to 100G/200G/400G Migration 2 DC global
More informationMTP/MPO Cable Assemblies
MTP/MPO Cable Assemblies MTP cable assemblies are multi-fiber patch cords suitable for high-density back plane and PCB solutions. MTP brand Fan-Out, Interconnect and Trunk cable offer up to 36 times the
More informationEverything you wanted to know about cabling, but were afraid to ask
Everything you wanted to know about cabling, but were afraid to ask Join the teleconference To receive a call back, click Communicate/Teleconference/Join Teleconference. In the pop-up window, enter your
More informationPhysical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks
Physical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks Agenda New ISO/IEC 11801 Standard New Fibre standards and encoding methods Higher speeds,
More informationNew standards that have led to higher speeds and new cable categories. Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks
New standards that have led to higher speeds and new cable categories Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks Three Realities of Networking #1 - Networks Never Go Slower Plan for higher
More informationMigratable cabling in computer centres for all data rates from Mbit/s to 100Gbit/s (DClink)
Introduction Computer centres must be reliable and available around the clock even during conversion work. Data rates are increasing constantly, and the FO cabling which only recently supported all applications
More informationDATA CENTER SOLUTIONS TM. Fiber Flex
DATA CENTER SOLUTIONS TM Fiber Flex We help reach your mission-critical objectives!! Olabs develops superior products and solutions in close collaboration with our customers. Our fiber optic structured
More informationHigh Speed Migration 100G & Beyond
High Speed Migration 100G & Beyond Moses Ngugi Field Application Engineer 5th September 2017 BANDWIDTH GROWTH Mobile Data IP Video Global Cloud IP Traffic Global IP Traffic Cisco CAGR: 50+% CAGR: 35%+
More informationAdrian Young Leviton Network Solutions
Adrian Young Leviton Network Solutions In This Session Multimode fiber types How many fibers do I need for my application? Future IEEE and non IEEE applications Will my existing fiber plant support these?
More informationDon t Get Left Behind: Cabling Designs You Can Trust to Support Speeds of 32G to 400G
Don t Get Left Behind: Cabling Designs You Can Trust to Support Speeds of G to 00G Dave Fredricks Data Center Infrastructure Architect #DATACENTERWORLD #CPEXPO CHANNELPARTNERSCONFERENCE.COM DATACENTERWORLD.COM
More informationIEEE Ethernet Working Group TIA TR-42 Liaison to IEEE 802.3
IEEE 802.3 Ethernet Working Group TIA TR-42 Liaison to IEEE 802.3 Valerie Maguire The Siemon Company Dallas, TX November 9, 2015 Page 1 Introduction to TIA Telecommunications Industry Association www.tiaonline.org
More informationStandards Update. Mylaraiah J N, RCDD Member, BICSI India Steering Committee
Standards Update Mylaraiah J N, RCDD Member, BICSI India Steering Committee Standards Update International Standards Interrelations Reference Guide Standard ISO/IEC CENELEC TIA/EIA Performance / Generic
More informationThe migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations
The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations White Paper www.commscope.com Contents Introduction 3 CommScope solution overview 3 InstaPATCH
More informationRoadmap to 400 Gigabit Ethernet over Multimode Fiber WHITEPAPER
Roadmap to 400 Gigabit Ethernet over Multimode Fiber WHITEPAPER The unprecedented exponential growth of information technology (IT) data is not a new finding. What is new is that there is now an end in
More informationPARKING. JDSU Solutions for Enterprise Structured Cabling
COMMUNICATIONS TEST AND MEASUREMENT SOLUTIONS JDSU Solutions for Enterprise Structured Cabling JDSU offers a complete range of communications test and measurement solutions to address the needs of cabling
More informationConnectorMax MPO Link Test Solution A COMPLETE MPO POLARITY, CONTINUITY AND CONNECTOR INSPECTION SOLUTION FOR SHORT FIBER LINKS (UP TO 5 KM)
A COMPLETE MPO POLARITY, CONTINUITY AND CONNECTOR INSPECTION SOLUTION FOR SHORT FIBER LINKS (UP TO 5 KM) All-in-one, easy-to-use solution to validate the polarity type, continuity and connector cleanliness
More informationWhite Paper: Choosing the RIght OTDR for your Datacenter
White Paper: Choosing the RIght OTDR for your Datacenter To ensure that fiber in datacenters is reliable, network professionals need a more accurate, easier, and faster methodology for assessing the integrity
More informationBase 8 Plug & Play. Fiber Solutions
Base 8 Plug & Play Fiber Solutions WWW.SIEMON.COM 8 About Base 8 Plug & Play Current 40 Gig (40GBASE-SR4) and 100 Gig (100GBASE-SR4) multimode fiber applications, as well as future 200 and 400 Gig multimode
More informationGigabit Ethernet Interconnect Technology
Gigabit Ethernet Interconnect Technology By Lisa A. Huff Segment Marketing Manager, Communications Gigabit Ethernet Description Ethernet is the world's most pervasive networking technology. More than 85%
More informationOFC/NFOEC 2011 Interoperability Demonstration
OFC/NFOEC 2011 Interoperability Demonstration March 7, 2011 1. Overview The Ethernet Alliance has twelve members participating in the OFC/NFOEC 2011 demonstration. The participating companies include:
More informationEnterprise Network Test Strategies for Network Availability and Performance. A Sitaramaiah Director Fluke Networks India
Enterprise Network Test Strategies for Network Availability and Performance A Sitaramaiah Director Fluke Networks India 1 Why is Enterprise Network Testing becoming increasingly important? IT is increasingly
More informationHDCi LX3 High Density 1U Patch Panel
HDCi LX3 High Density 1U Patch Panel An innovative 1U, 19 rack mountable patch panel, designed for use in high density applications. It offers management of up to 144 fibres using MTP optical cassette
More informationData center applications standards reference guide
White paper Data center applications standards reference guide Networking and storage Contents Scope 3 Introduction 3 Data center cabling standard ISO/IEC 24764 3 Ethernet (IEEE 802.3) 4 Proprietary 40
More informationLX3 High Density LGX 1U Patch Panel
LX3 High Density LGX 1U Patch Panel An innovative 1U, 19 rack mountable patch panel, designed for use in high density applications. It offers management of up to 144 fibres using MTP optical cassette modules
More informationPreCONNECT OCTO PRODUCT INFORMATION
PreCONNECT OCTO PRODUCT INFORMATION Applications Infrastructure and IT room cabling within data centers System consists of: Factory assembled OFNR Riser or OFNP Plenum rated n x 8 fiber Microunit Breakout
More informationARISTA 7500R/7500E/7300X Connectivity Guide CABLExpress 1. ARISTA 7500R/7500E/7300X Connectivity Guide
ARISTA 7500R/7500E/7300X Connectivity Guide CABLExpress 1 ARISTA 7500R/7500E/7300X Connectivity Guide How do you protect and improve the functionality of your critical processes? You have to Respect Layer
More informationOpt-X Unity. 40/100G Fiber Optic System
Opt-X Unity 40/100G Fiber Optic System PREPARE FOR 40/100G WITH THE LEVITON PRE-TERMINATED FIBER MULTIMODE SYSTEM The Opt-X Unity 40/100G laser optimized multimode (LOMM) system offers an ideal migration
More informationApplications Engineering Notes. The US Conec MTP Multifiber Connector
Applications Engineering Notes Document Title Document Number The US Conec MTP Multifiber Connector AEN-1909 Revision Number Rev 2.0 Effective Date June 1, 2008 1.0 Document Purpose The purpose of this
More informationFMT4S. High Density Connectivity Solution
FMT4S High Density Connectivity Solution 2 FMT4S Solution Illustration FMT4S Optical Distribution Frame (ODF) FMT4S series is an advanced ODF series offering premium quality Data Center connectivity solution.
More informationLeaders in the Advancement of Multimode Fiber. Fiber Future and Beyond
Leaders in the Advancement of Multimode Fiber Fiber Future and Beyond Major Milestones in the Advancement of Multimode Fiber (MMF) Transmission OM4 Signature Core Fiber Cabling TIA WBMMF ISO/IEC OM5 (WBMMF)
More informationThe interface ports are selectively enabled based on their functions in the system management versus non-management.
This chapter describes how to cable the interface ports on Management I/O (MIO) or Management I/O Universal (UMIO) cards. It includes the following sections: Interface Ports, page Port Status LEDs, page
More informationJamey Calloway, RCDD Product Management Specialist Optical Cable Corporation
Testing and deployment of direct attach and the impact of category 8 Thursday, 10 August 2017, 3:50-4:40 P.M. Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation Overview Traditional
More informationOptical Trends in the Data Center. Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Optical Communications
Optical Trends in the Data Center Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Optical Communications Telecom 2017 Corning Restricted Incorporated 2 Server Access Switch
More informationArista 7500 Series Interface Flexibility
Arista 7500 Series Interface Flexibility Today s large-scale virtualized datacenters and cloud networks require a mix of 10Gb, 25Gb, 40Gb, 50Gb and 100Gb Ethernet interface speeds able to utilize the widest
More information100G and Beyond: high-density Ethernet interconnects
100G and Beyond: high-density Ethernet interconnects Kapil Shrikhande Sr. Principal Engineer, CTO Office Force10 Networks MIT MicroPhotonics Center Spring Meeting April 5, 2011 [ 1 ] Ethernet applications
More informationOM3/OM4 FIBER CABLING SYSTEM. System Benefits
About ncompass ncompass is an innovative product offering of structured cabling solutions created by Legrand and Superior Essex. Understanding your communications challenges allows us to offer you multiple,
More informationHDCi LX3 High Density 4U Patch Panel
HDCi LX3 High Density 4U Patch Panel An innovative 4U, 19 rack mountable patch panel, designed for use in high density applications. It offers management of up to 576 fibres using MTP optical cassette
More informationIntegrate 10 Gb, 40 Gb and 100 Gb Equipment More Efficiently While Future-Proofing Your Fiber and Copper Network Infrastructure
W H I T E P A P E R Integrate 10 Gb, 40 Gb and 100 Gb Equipment More Efficiently While Future-Proofing Your Fiber and Copper Network Infrastructure Executive Summary Growing demand for faster access to
More informationHI-DEX is an ultra high-performance, pre-terminated and modular optical fibre cabling system based on MT ferrule connector technology.
APPLICATION HI-DEX is an ultra high-performance, pre-terminated and modular optical fibre cabling system based on MT ferrule connector technology. This product set is designed for installation in the data
More informationCommon Mistakes Made in Certification Specifications and Testing. Jim Davis Regional Marketing Engineer Fluke Networks
Common Mistakes Made in Certification Specifications and Testing Jim Davis Regional Marketing Engineer Fluke Networks Common Mistake #1 Failing to specify a Permanent Link test #1 Permanent Link or Channel?
More informationPhysical Layer V What does the physical layer provide?
SEMESTER 1 Chapter 8 Physical Layer V 4.0 90 Points 8.1.1 What does the physical layer provide? What are the four elements of delivering frames across the media? 8.1.2 What are the three basic forms of
More informationTransceiver Fiber Inspection and Cleaning
Application Note Transceiver Fiber Inspection and Cleaning VIAVI Solutions Introduction This document provides basic overview and background information for transceiver types that are commonly used in
More informationDELL EMC NETWORKING TRANSCEIVERS AND CABLES
DELL EMC NETWORKING TRANSCEIVERS AND CABLES Features and benefits Hot-swappable for simplified maintenance (no power-down required for installation or replacement) Some of the smallest and lowestpower
More informationUsing Low DMD, Laser Optimized Multimode Fiber to Expand 10-Gigabit Network Design Options
Using Low DMD, Laser Optimized Multimode Fiber to Expand 10-Gigabit Network Design Options Lisa Huff Technical Manager, Advanced Design & Applications Berk-Tek, a Nexans Company Adam Murano Fiber Engineering
More informationOptical Trends in the Data Center
Optical Trends in the Data Center Romeo Lazar Sales Manager, Eastern Europe Corning Optical Communications EMEA September 2016 Agenda Agenda Corning overview Data Center Server and Switch Trends Standards
More information