Technical results from TDC vectoring field trial in Folby

Size: px
Start display at page:

Download "Technical results from TDC vectoring field trial in Folby"

Transcription

1 Technical results from TDC vectoring field trial in Folby 14th January

2 Vectoring trial Folby The test site is a part of the village Folby, between Aarhus og Randers 2

3 Vectoring trial general conditions The site is classified as remote exchange. This means that a mix of ADSL2+ and VDSL2 is in use. DPBO is not applied. This makes the site reasonably representative for the crosstalk conditions around small COs and remote exchanges, but not for remote injection points where DPBO is applied and only VDSL2 is deployed In a cable between the remote exchange building and passive distributer HN12 there is a suitable number of VDSL2 customers. 15 additional VDSL2 CPEs (dummy customers) are installed in a shed very close to distributer, in order to increase crosstalk noise (simulating a small apartment block) A few VDSL2 customers did not want to be included in the trial. Luckily, they could all be served on a profile limited to the ADSL2+ frequency band, so alien VDSL2 lines could be avoided There are no unbundled lines or VDSL2 BSA customers in the test area 3

4 Vectoring trial technology The test DSLAM is an ALU ISAM DSLAM with 2 vectoring enabled VDSL2 line cards, type NDLT-F. Dummy customers are connected to one card, the real test customers to the other System level vectoring is applied using a Vectoring processer type NDPS-A, supporting up to 192 ports DSLAM SW version: d The CPEs are Broadcom based modems, Sagem FAST 5310; SW A2pv6F038h The real customers keep their original TDC RGW supporting triple play service, WIFI etc. The vectoring modems are connected between line and RGW (2-box setup) Two alternative CPE units with same chipset type were used for some measurements 4

5 Topologi Sub CO with DSLAM Passive distributer HN 12 Test customers, including dummy customers, are connected to HN12, with the exception of a few real customers connected to drops on main cable to HN12 (400 pairs, binder type) 5

6 General status for trial primo January real customers are connected. 19 of these subscribe to a triple play service with SD and HD TV 15 dummy customers are connected close to passive distributer HN12 (port 1-15) (simulating a small apartment block) 1 dummy customer is connected directly at MDF (0 loop length, used as reference) There is a high fill of active ADSL2+ lines in the cables Test lines are configured with 17a profile with the exception of the longest line where 8b is used. Frequency plan: 998ADE17 6

7 General status for trial primo January 2013 (2) Vectoring is disabled in the ADSL2+ band UPBO ETSI F is used on all lines (standard DK VDSL2 configuration) Loop attenuation vary between 3 and 12 db@150 khz G.INP and SRA is used on all lines All lines are profile capped to max 108 Mb/s in DS. This cab is chosen to avoid limitation of US due to memory limitation in chipsets. A further limitation is the Ethernet 100 Mb/s interface on the CPEs, making it impossible to demonstrate actual rates beyond 100 Mb/s. For some experiments a higher cap was chosen and an alternative CPE unit with 1 Gb interface was used 7

8 Heat map for coupling between pairs Tx Referred FEXT [dbm/hz] LT 1/1/7 Real customers LT 1/1/9 Dummy customers Victim [line no. + (no. board)*100] CROSSTALK MATRIX TRANSMITTER REFERED FEXT Disturber Strong crosstalk present on some lines. Very strong crosstalk between 2 pairs (adjacent pairs in main cable) 8

9 Reach-rate diagram 9

10 Vectoring gain 10

11 Co-existence with ADSL2+ It is clearly seen that bitloading is reduced due to ADSL2+ crosstalk up to bin 512 (2.2 MHz) The drop corespond to 5-6 Mb/s in DS At higher frequencies a smooth roll off is seen Port 22 is connected to a short line 11

12 Other observations and planned measurements The stability of lines is monitored. Some lines show a few errored seconds/15 min. Otherwise the lines are clean (they all fall into TDC stability class Perfect ) In two house installations bridge tabs (10-15 m) were detected and removed by technician. Apart from this, the lines were not touched US vectoring gain will be investigated further. Due to configuration there is at present a cab at 30 Mb/s. Tests with different memory split are planned, and so are test with modified UPBO profile, including no UPBO. The planned tests also included stability tests with G.INP disabled and classical IFEC in use, provoked disorderly leaves, robustness to intermitted RFI ingress etc. The trial will be terminated by the end of February 12

13 Preliminary conclusion The results seen up to now demonstrate that: The expected gain in DS bandwidth is achieved The loss due to not-cancelled ADSL2+ crosstalk noise is as expected The lines serving the real customers are stable and the triple play service is running OK US bandwidth performance need further investigation 13

Zero-touch VDSL2 vectoring

Zero-touch VDSL2 vectoring Zero-touch VDSL2 vectoring Copper broadband performance Copper broadband plays a key part in New Zealanders broadband experience. The introduction of new technologies such as vectoring and G.INP continue

More information

xdsl crosstalk cancellation

xdsl crosstalk cancellation xdsl crosstalk cancellation Technology potentials derived from measurements on a VDSL2-vectored system Miguel Peeters Globecom 29 www.broadcom.com Outline Vectoring Definition and status. Prototype and

More information

Standard VDSL Technology

Standard VDSL Technology Standard VDSL Technology Overview of European (ETSI), North American (T1E1.4) and International (ITU-T) VDSL standard development Vladimir Oksman Broadcom Corporation July 2001 Slide 1 Current status of

More information

DYNAMIC LINE MANAGEMENT FOR VECTORING SCENARIOS

DYNAMIC LINE MANAGEMENT FOR VECTORING SCENARIOS DYNAMIC LINE MANAGEMENT FOR VECTORING SCENARIOS STRATEGIC WHITE PAPER Operators are embracing vectoring technology as a means to extend and protect their legacy investments in copper access. However, the

More information

DSL Consortium. VDSL2 Rate vs. Reach Interoperability Test Suite (V2RR) Version Last Updated: March 24, 2008

DSL Consortium. VDSL2 Rate vs. Reach Interoperability Test Suite (V2RR) Version Last Updated: March 24, 2008 Test Suite (V2RR) Version 1.2.0 Last Updated: March 24, 2008 121 Technology Drive, Suite 2 University of New Hampshire Durham, NH 03824 Phone: +1-603-862-2911 Fax: +1-603-862-4181 www.iol.unh.edu 2006

More information

Service Performance Management

Service Performance Management Service Performance Management Broadband and data tests overview The following tests are used to troubleshoot broadband and data services: TEST DESCRIPTION Line State Diagnosis (LSD) Analyses the current

More information

Loop Spectrum Compatibility and Management

Loop Spectrum Compatibility and Management Loop Spectrum Compatibility and Management by Jim Carlo Texas Instruments jcarlo@ti.com Spectrum Management Mission statement: Utilize installed base of twisted copper pairs for delivering high speed broadband

More information

VDSL in terms of reach and capacity

VDSL in terms of reach and capacity ANSI TE.4/97-38 () Standards project: TE.4: VDSL Title : Zipper performance when mixing ADSL and VDSL in terms of reach and capacity Source : Contact: Telia Research AB Daniel Bengtsson, Petra Deutgen,

More information

Alcatel-Lucent Internal

Alcatel-Lucent Internal Next Generation Access: 10G PON & Phantom Mode The Evolution Towards Ultra-Broadband Sanjay S. Patel CTO, Wireline Division Alcatel-Lucent Alcatel-Lucent Internal How much bandwidth do you need? Long term

More information

The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.

The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein. OPEN template Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners. The information presented is

More information

NEXT GENERATION BROADBAND SYSTEMS DEPLOYMENT IN CUSTOMER CABLING Introductory Tutorial on C658:2018 Deployment Rules

NEXT GENERATION BROADBAND SYSTEMS DEPLOYMENT IN CUSTOMER CABLING Introductory Tutorial on C658:2018 Deployment Rules NEXT GENERATION BROADBAND SYSTEMS DEPLOYMENT IN CUSTOMER CABLING Introductory Tutorial on C658:2018 Deployment Rules April 2018 Communications Alliance Outline: Applicability and Overall Objectives Key

More information

COMMITTEE T1 TELECOMMUNICATIONS Working Group T1E1.4 (DSL Access) Newport Beach, CA; Feb 17 th, 2002 CONTRIBUTION

COMMITTEE T1 TELECOMMUNICATIONS Working Group T1E1.4 (DSL Access) Newport Beach, CA; Feb 17 th, 2002 CONTRIBUTION COMMITTEE T1 TELECOMMUNICATIONS Working Group T1E1.4 (DSL Access) Newport Beach, CA; Feb 17 th, 2002 T1E1.4/2003-049 CONTRIBUTION TITLE: SOURCES: Dynamic FDM and Dynamic DS power back-off: A simplified

More information

DYNAMIC UPSTREAM POWER BACK-OFF FOR MIXTURES OF VECTORED AND NON-VECTORED VDSL Ming-Yang Chen, Georgios Ginis, and Mehdi Mohseni

DYNAMIC UPSTREAM POWER BACK-OFF FOR MIXTURES OF VECTORED AND NON-VECTORED VDSL Ming-Yang Chen, Georgios Ginis, and Mehdi Mohseni 2014 IEEE International Conference on Acoustic, Speech and Signal Processing (ICASSP) DYNAMIC UPSTREAM POWER BACK-OFF FOR MIXTURES OF VECTORED AND NON-VECTORED VDSL Ming-Yang Chen, Georgios Ginis, and

More information

Introduction to ADSL

Introduction to ADSL Introduction to ADSL Christian Truppel ADSL Explained The costs of exchanging large numbers of bits and bytes used to be equally high for all available methods. Whilst large companies used microwave and

More information

1-Port 10/100/1000T Ethernet to VDSL2 Converter w/ G.vectoring

1-Port 10/100/1000T Ethernet to VDSL2 Converter w/ G.vectoring 1-Port 10/100/1000T Ethernet to Converter w/ G.vectoring ITU-T G.993.5 G.vectoring and G.INP DMT-based coding technology Built-in POST splitter to share voice and date CO/CPE mode selectable via DIP switch

More information

An Overview. 12/22/2011 Hardev Singh Manager (BB-NOC) MTNL Delhi

An Overview. 12/22/2011 Hardev Singh Manager (BB-NOC) MTNL Delhi Broadband Technology An Overview 12/22/2011 Hardev Singh Manager (BB-NOC) MTNL Delhi 1 1 2 3 4 5 6 7 8 9 * 8 # 1 2 3 4 5 6 7 8 9 * 8 # Typical Narrowband (voice) setup Local Exchange PSTNSwitch telephone

More information

Exploring the boundaries of G.fast

Exploring the boundaries of G.fast Exploring the boundaries of G.fast Paul Spruyt xdsl Strategist 18 June, 2015 1 Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the

More information

Wired Broadband Access How far can we go with wires?

Wired Broadband Access How far can we go with wires? Wired Broadband Access How far can we go with wires? Prepared For: Gilhousen Telecommunications Colloquium Montana State University Telcordia Contacts: Dave Waring 973.829.4850 dlw@research.telcordia.com

More information

4-Port 10/100/1000T Ethernet to VDSL2 Bridge w/g.vectoring

4-Port 10/100/1000T Ethernet to VDSL2 Bridge w/g.vectoring 4-Port 10/100/1000T Ethernet to Bridge w/g.vectoring ITU-T G.993.5 G.Vector and G.INP DMT-based coding technology Built-in POST splitter to share voice and date One RJ11 connector for VDSL port with VDSL

More information

Metanoia. Metanoia Milestones

Metanoia. Metanoia Milestones Product Briefs Product Brief Collection -Company profile Metanoia Metanoia Milestones 2004: Founded in Hsinchu, Taiwan 2006: First VDSL chip launched 2006: Merged with Metanoia US 2008: First 30a chip

More information

Outline: nbn tm compliancy Range overview NetComm Wireless gateway portfolio Product comparison Pricing. Fixed Broadband - Outline

Outline: nbn tm compliancy Range overview NetComm Wireless gateway portfolio Product comparison Pricing. Fixed Broadband - Outline Outline: nbn tm compliancy Range overview NetComm Wireless gateway portfolio Product comparison Pricing Fixed Broadband - Outline NetComm Wireless product strategy NetComm Wireless has created a future

More information

G.fast Ultrafast Access Technology Standardization in ITU-T

G.fast Ultrafast Access Technology Standardization in ITU-T G.fast Ultrafast Access Technology Standardization in ITU-T Yoshihiro Kondo Abstract The International Telecommunication Union - Telecommunication Standardization Sector (ITU-T) Study Group 15 (SG15) is

More information

NICC ND 1436 V1.1.2 ( )

NICC ND 1436 V1.1.2 ( ) NICC Document Wires-only VDSL2 Modem Test Plan Michael Faraday House, Six Hills Way, Stevenage SG1 2AY Tel.: +44(0) 20 7036 3636 Registered in England and Wales under number 6613589 2 NOTICE OF COPYRIGHT

More information

1-Port 10/100/1000T 802.3at PoE+ Ethernet to VDSL2 Converter

1-Port 10/100/1000T 802.3at PoE+ Ethernet to VDSL2 Converter 1-Port 10/100/1000T 802.3at + Ethernet to Converter Physical Ports 1-port 10/100/1000BASE-T RJ45 with IEEE 802.3af/802.3at Injector 1 RJ11, connector for xdsl port with or ADSL2+ connection Plus High Performance

More information

Introducing CopperPro Series II

Introducing CopperPro Series II Introducing CopperPro Series II The Next Generation copper loop test set Superior, feature-rich copper loop testing capabilities Advanced wideband troubleshooting and qualification for broadband services,

More information

G.fast performance and impact across Orange Networks. Hubert Mariotte Orange Labs G.fast Summit, Paris, May 21st, 2015

G.fast performance and impact across Orange Networks. Hubert Mariotte Orange Labs G.fast Summit, Paris, May 21st, 2015 G.fast performance and impact across Orange Networks Hubert Mariotte Orange Labs G.fast Summit, Paris, May 21st, 2015 Orange deploying VHBB in Europe France 11,1M ADSL, 350k VDSL(CO), 560k GPON, 3.6 millions

More information

Revised Proposed Shaped Extended Upstream PSD for Inclusion in Annex M ABSTRACT

Revised Proposed Shaped Extended Upstream PSD for Inclusion in Annex M ABSTRACT BB ITU-T PSD G.992.3 Annex M/C G.992.5 M/C Annex M PSD PSD PSD ANFP TTC PSD ITU - Telecommunication Standardization Sector STUDY GROUP 15 Temporary Document LB-xxx Original: English Leuven, Belgium 14-18

More information

DEERE AFFIDAVIT Attachment PPP

DEERE AFFIDAVIT Attachment PPP DEERE AFFIDAVIT Attachment PPP DEERE ATTACHMENT PPP VERY LOW-BAND SYMMETRIC TECHNOLOGY NETWORK INTERFACE/INTERCONNECTION SPECIFICATIONS TP76750 ISSUE 1 February 1999 Southwestern Bell Telephone Pacific

More information

DEERE AFFIDAVIT Attachment OOO

DEERE AFFIDAVIT Attachment OOO DEERE AFFIDAVIT Attachment OOO DEERE ATTACHMENT OOO Mid-band Symmetric Technology NETWORK INTERFACE/INTERCONNECTION SPECIFICATIONS TP76740 ISSUE 1 February 1999 Southwestern Bell Telephone Pacific Bell

More information

Model VxT-48-DC+ xtalk Emulator for Vectored VDSL2 Testing

Model VxT-48-DC+ xtalk Emulator for Vectored VDSL2 Testing Results You Can Count On Reference Manual Model VxT-48-DC+ xtalk Emulator for Vectored VDSL2 Testing Rev - Date of Publication: 9/02/2014 Automated Performance Testing Solution for VDSL2 Vectoring Standards-Based

More information

TR-114 VDSL2 Performance Test Plan

TR-114 VDSL2 Performance Test Plan TECHNICAL REPORT TR-114 VDSL2 Performance Test Plan Issue: 1 Corrigendum 1 Issue Date: March 2010 The Broadband Forum. All rights reserved. Notice The Broadband Forum is a non-profit corporation organized

More information

NICC ND 1517 V1.1.1 ( )

NICC ND 1517 V1.1.1 ( ) NICC Document Report on the Technical Feasibility of Deployment Options for VDSL from the Exchange Michael Faraday House, Six Hills Way, Stevenage SG1 2AY Tel.: +44(0) 20 7036 3636 Registered in England

More information

MANAGING UNVECTORED LINES IN A VECTORED GROUP

MANAGING UNVECTORED LINES IN A VECTORED GROUP MANAGING UNVECTORED LINES IN A VECTORED GROUP STRATEGIC WHITE PAPER Vectoring technology supports the removal of far-end crosstalk (FEXT) from coordinated lines. However, challenges arise when vectored

More information

Delivering copper-based broadband access services at 100 Mbps. George Ginis February 12 th, 2014

Delivering copper-based broadband access services at 100 Mbps. George Ginis February 12 th, 2014 Delivering copper-based broadband access services at 100 Mbps George Ginis February 12 th, 2014 1 Vectored VDSL Needs More than Copper Network Operations Support Systems DSL monitoring and optimization

More information

Creating the Gigabit Home Network. Anthony Zuyderhoff VP CPE Sales & Sales Engineering EMEA

Creating the Gigabit Home Network. Anthony Zuyderhoff VP CPE Sales & Sales Engineering EMEA Creating the Gigabit Home Network Anthony Zuyderhoff VP CPE Sales & Sales Engineering EMEA Market trends for Connected Home More Devices Faster Speeds Emerging IoT Better Video 4K & UHD HEVC Improved Wireless

More information

Realization of Adaptive NEXT canceller for ADSL on DSP kit

Realization of Adaptive NEXT canceller for ADSL on DSP kit Proceedings of the 5th WSEAS Int. Conf. on DATA NETWORKS, COMMUNICATIONS & COMPUTERS, Bucharest, Romania, October 16-17, 006 36 Realization of Adaptive NEXT canceller for ADSL on DSP kit B.V. UMA, K.V.

More information

DSL technology and deployment

DSL technology and deployment DSL technology and deployment Contributed by Sascha Lindecke Director of Marketing Broadband Access Sascha.lindecke@infineon.com Today there are various DSL Technology Options Family ITU Name Ratified

More information

You Can t Fake Fast. The Promise of 100 Mbps and Vectored Services Raises Bar on Network Quality. White Paper

You Can t Fake Fast. The Promise of 100 Mbps and Vectored Services Raises Bar on Network Quality. White Paper You Can t Fake Fast he Promise of 100 Mbps and Vectored Services aises Bar on Network Quality he next generation of VDSL2 technology call Bonding & Vectoring promises performances upwards of 100Mbs on

More information

History Channel. 10G Ethernet on Copper

History Channel. 10G Ethernet on Copper 10G Ethernet on Copper History Channel Category Cable by Supported Technology Cat 1 - Telephone cable, ISDN Cat 3-10BaseT Cat 5-100BaseTX Cat 5e - 1000BaseT Cat 6-1000BaseT, but what about 10 Gigabit???

More information

All rights reserved 2006, Alcatel. The Role of GPON. November 29, Globecom 06. Ralph Ballart. In Supporting Triple Play Services

All rights reserved 2006, Alcatel. The Role of GPON. November 29, Globecom 06. Ralph Ballart. In Supporting Triple Play Services The Role of GPON In Supporting Triple Play Services Ralph Ballart Globecom 06 November 29, 2006 Agenda! Introduction! New Video Paradigms! How Much Bandwidth Is Enough?! VDSL2! Gigabit Passive Optical

More information

HST-3000 Class of Service (CoS) Test Suite

HST-3000 Class of Service (CoS) Test Suite Application Note HST-3000 Class of Service (CoS) Test Suite By John Williams The development of new Internet Protocol (IP)-packet based, so called Triple-Play, services (voice, video, data) delivered over

More information

Network Access Technology Consideration in Europe. By Helge Tiainen of InCoax and Chair of the MoCA Access Work Group

Network Access Technology Consideration in Europe. By Helge Tiainen of InCoax and Chair of the MoCA Access Work Group Network Access Technology Consideration in Europe By Helge Tiainen of InCoax and Chair of the MoCA Access Work Group Introduction There is no shortage of networking alternatives to reach multi-dwelling

More information

Frequently Asked Questions

Frequently Asked Questions Contents System... 3 Screen capture of pop-ups and tray menu?... 3 Battery charge time?... 3 How to differentiate between OneExpert and HST power supply?... 3 Car adapter?... 3 Remote Operation through

More information

1-Port Gigabit Ethernet over Coaxial Converter

1-Port Gigabit Ethernet over Coaxial Converter 1-Port Gigabit Ethernet over Coaxial Converter ITU-T G.993.5 G.Vectoring and G.INP Upstream/Downstream bandwidth up to 200/100Mbps CO/CPE mode selectable via DIP switch Selectable target band plan and

More information

Extending Copper Access Networks with Vectoring and G.Fast: Why Fiber Isn t a Must

Extending Copper Access Networks with Vectoring and G.Fast: Why Fiber Isn t a Must Extending Copper Access Networks with Vectoring and G.Fast: Why Fiber Isn t a Must An Infonetics Research Webinar #gfast #fttdp Today s Speakers #gfast #fttdp Kurt Raaflaub Global Product Marketing, Carrier

More information

A SIMPLE POLYNOMIAL METHOD FOR OPTIMIZING UPSTREAM PERFORMANCE IN MULTIUSER VDSL2 LINES

A SIMPLE POLYNOMIAL METHOD FOR OPTIMIZING UPSTREAM PERFORMANCE IN MULTIUSER VDSL2 LINES XX IMEKO World Congress Metrology for Green Growth September,, Busan, Republic of Korea A SIMPLE POLYNOMIAL METHOD FOR OPTIMIZING UPSTREAM PERFORMANCE IN MULTIUSER VDSL LINES Hernan X. Cordova, Leo Van

More information

Release Notes for Cisco 860VAE Series Multimode VDSL2/ADSL2/2+ DSL Router using Firmware Release ABpv6C035j

Release Notes for Cisco 860VAE Series Multimode VDSL2/ADSL2/2+ DSL Router using Firmware Release ABpv6C035j Release s for Cisco 860VAE Series Multimode VDSL2/ADSL2/2+ DSL Router using Firmware Release ABpv6C035j First Published: August 30, 2012 Release: Cisco IOS Release 15.2(4)M Contents Introduction, page

More information

This paper discusses home networks that can deliver video as well as data and their growing sophistication and capacity.

This paper discusses home networks that can deliver video as well as data and their growing sophistication and capacity. Hybrid Coax/PLC Video Distribution Home Networks This paper discusses home networks that can deliver video as well as data and their growing sophistication and capacity. Hybrid networks are based on existing

More information

SmartClass ADSL/Copper Combo Kickstart Training

SmartClass ADSL/Copper Combo Kickstart Training SmartClass ADSL/Copper Combo Kickstart Training Customer Name Presenters Name Place Date Version 3.0 Welcome! Welcome! At the end of this training you will: Be familiar with the use of the SmartClass ADSL

More information

May 2nd 2011 has arrived, all of AT&T broadband customers now have uveruse CAPs.

May 2nd 2011 has arrived, all of AT&T broadband customers now have uveruse CAPs. A personal evaluation of AT&T's Uverse FTTN (fiber to the node) May 2nd 2011 has arrived, all of AT&T broadband customers now have uveruse CAPs. Many of our blog visitors reach our site as the result of

More information

Internet Access Technologies

Internet Access Technologies Lecture 4: Local Loop Technologies, Internet Access and Leased Lines Dr. Mohammed Hawa Electrical Engineering Department University of Jordan EE426: Communication Networks Internet Access Technologies

More information

end systems, access networks, links circuit switching, packet switching, network structure

end systems, access networks, links circuit switching, packet switching, network structure Introduction Chapter 1: roadmap 1.1 What is the Internet? 1.2 Network edge end systems, access networks, links 1.3 Network core circuit switching, packet switching, network structure 1.4 Delay, loss and

More information

Triple Play Services Transmission over VDSL2 Broadband Access Network in MDU

Triple Play Services Transmission over VDSL2 Broadband Access Network in MDU Triple Play Services Transmission over VDSL2 Broadband Access Network in MDU Nasser N. Khamiss, Sara Ali Abed Al-Hussein Networks Engineering Department, College of Information Engineering, Al-Nahrain

More information

DLS 8130 Operating Manual VDSL2 Wireline Simulator North America

DLS 8130 Operating Manual VDSL2 Wireline Simulator North America DLS 8130 Operating Manual VDSL2 Wireline Simulator North America Version 1.0. December 2005 71-000145 V1.0 DLS 8130 Operating Manual Copyright Notice 2005 Spirent Communications Manual Part Number 71-000145

More information

PSTN, NGA and cable access networks compared: a technical perspective

PSTN, NGA and cable access networks compared: a technical perspective FACULTE D INFORMATIQUE 1/20 PSTN, NGA and cable access networks compared: a technical perspective L. Schumacher (FUNDP The University of Namur) CLEC Seminar, September 30 th, 2010 FACULTE D INFORMATIQUE

More information

Asymmetrical Digital Subscriber Line (ADSL)

Asymmetrical Digital Subscriber Line (ADSL) Asymmetrical Digital Subscriber Line (ADSL) Asymmetrical Digital Subscriber Line Background motivation for developing ADSL historical development DSL end-to-end environment and reference model Line environment

More information

MORE ETHERNET ON THE HORIZON WHO NEEDS 2.5G AND 5G ETHERNET? Krzysztof Ojdana, Product Manager WHITE PAPER. Molex Connected Enterprise Solutions

MORE ETHERNET ON THE HORIZON WHO NEEDS 2.5G AND 5G ETHERNET? Krzysztof Ojdana, Product Manager WHITE PAPER. Molex Connected Enterprise Solutions MORE ETHERNET ON THE HORIZON WHO NEEDS 2.5G AND 5G ETHERNET? Krzysztof Ojdana, Product Manager WHITE PAPER Molex Connected Enterprise Solutions EXECUTIVE SUMMARY Ethernet seems to be one of the fastest

More information

Supporting Document NASMS

Supporting Document NASMS Supporting Document NASMS Contents 1 General Information... 3 1.1 PIN Code... 3 1.2 Intended Use... 3 1.3 Functionality... 3 1.4 Suggestions / Feedback... 4 1.5 Special Cases... 4 1.6 SMS Server Error

More information

That enable you to maximize the Bandwidth capability of your Access Network Investment

That enable you to maximize the Bandwidth capability of your Access Network Investment / VALUE STATEMENT We are dedicated to developing World-class customizable CPE Solutions That enable you to maximize the Bandwidth capability of your Access Network Investment While we are focused on Lowering

More information

Technical Specification for High Density UniSplit ADSL Central Office and Remote Cabinet Splitter

Technical Specification for High Density UniSplit ADSL Central Office and Remote Cabinet Splitter Version 1.0-08/2008 Telecom Outside Plant Technical Specification for High Density UniSplit ADSL Central Office and Remote Cabinet Splitter 1. DESCRIPTION 2. TECHNICAL REFERENCES 3. WIRING SCHEMATIC SP-USL.HD-vr1.1

More information

HST-3000 Handheld Services Tester Platform Overview

HST-3000 Handheld Services Tester Platform Overview Provided by www.aaatesters.com HST-3000 Handheld Services Tester Platform Overview Experience the Power of One The growth of converged services has changed the landscape of the telecommunications industry,

More information

1-Port 10/100/1000T Ethernet over Coaxial Converter

1-Port 10/100/1000T Ethernet over Coaxial Converter 1-Port 10/100/1000T Ethernet over Coaxial Converter ITU-T G.993.5 G.Vectoring and G.INP Upstream/Downstream bandwidth up to 200/100Mbps CO/CPE mode selectable via DIP switch Selectable target band plan

More information

The Broadband Revolution

The Broadband Revolution The Broadband Revolution Broadband is a culture that has changed how we work, shop, play and communicate. Key to any culture is learning from others and adopting beneficial practices. Broadband technologies

More information

Capacity analysis of RT-based VDSL2 copper access networks. 1 Interference from binder pairs is calculated using the FSAN method of

Capacity analysis of RT-based VDSL2 copper access networks. 1 Interference from binder pairs is calculated using the FSAN method of Capacity analysis of RT-based VDSL2 copper access networks Vedran Mikac, Student Member, IEEE, Željko Ilić, Member, IEEE, Tomaž Beriša, Member, IEEE, Alen Bažant, Senior Member, IEEE, Mladen Kos, Senior

More information

WHITE PAPER. G.fast WHITE PAPER. G.fast promises to seriously boost signal speeds to customer premises. OVERVIEW

WHITE PAPER. G.fast WHITE PAPER. G.fast promises to seriously boost signal speeds to customer premises. OVERVIEW G.fast Testing the new DSL technology that boosts speed over copper local loops OVERVIEW Telcos have offered customers Digital Subscriber Line (DSL) solutions for decades. DSL provides digital communication

More information

Better broadband is coming to Hangatiki OHA/E ISAM UPGRADE

Better broadband is coming to Hangatiki OHA/E ISAM UPGRADE Better broadband is coming to Hangatiki OHA/E ISAM UPGRADE HANGATIKI BROADBAND UPGRADE 17 August 2016 PAGE 1 Better landline broadband is coming to Hangatiki residents Chorus has a upgrade scheduled for

More information

NICC ND 1405 V3.1.2 ( )

NICC ND 1405 V3.1.2 ( ) NICC Document Guidelines on the Use of DSL Transmission Systems in the BT Access Network Version 3.1.2 Michael Faraday House, Six Hills Way, Stevenage SG1 2AY Tel.: +44(0) 20 7036 3636 Registered in England

More information

Guest Editorial. Twisted Pair Transmission Ever Increasing Performances on Ancient Telephone Wires

Guest Editorial. Twisted Pair Transmission Ever Increasing Performances on Ancient Telephone Wires Guest Editorial Twisted Pair Transmission Ever Increasing Performances on Ancient Telephone Wires Werner Henkel, Sedat Ölçer, Krista Jacobsen, and Burton Saltzberg Digital subscriber line (DSL) technology

More information

VES-1616FE/1624FT-55A

VES-1616FE/1624FT-55A VES-1616FE/1624FT-55A 16/24-port VDSL2 remote IP DSLAM Support Notes Version 3.53 10/2008 Edition 2 Table of Contents TABLE OF CONTENTS...1 IPQOS...4 WHAT IS IPQOS?...4 IPQOS PARAMETERS...4 IPQOS EXAMPLES...6

More information

02/15/01 1 T1E1.4/ Contact: J. Cioffi, Dept of EE, Stanford U., Stanford, CA , F:

02/15/01 1 T1E1.4/ Contact: J. Cioffi, Dept of EE, Stanford U., Stanford, CA , F: 02/15/01 1 T1E1.4/2001-088 Project: T1E1.4: Spectrum Management II Title: Unbundled DSL Evolution (088) Contact: J. Cioffi, Dept of EE, Stanford U., Stanford, CA 94305 cioffi@stanford.edu, 1-650-723-2150,

More information

Delivering faster broadband, further...

Delivering faster broadband, further... Delivering faster broadband, further... Broadband technology solutions for existing NETWORK INFRASTRUCTURES Page 1 Address the challenge of delivering more for less Delivering faster broadband, further

More information

600 SERIES. Transparent Switching Matrix Modules for High-Bandwidth DSL Test Automation. Reference Manual. Rev A. Version 2.6.0

600 SERIES. Transparent Switching Matrix Modules for High-Bandwidth DSL Test Automation. Reference Manual. Rev A. Version 2.6.0 Results You Can Count On Reference Manual 600 SERIES Transparent Switching Matrix Modules for High-Bandwidth DSL Test Automation Rev A Version 2.6.0 Date of Publication: 03/05/2019 Customer Care Warranty

More information

Ethernet over VDSL2 Converter/Bridge VC-231G VC-234G

Ethernet over VDSL2 Converter/Bridge VC-231G VC-234G Ethernet over VDSL2 Converter/Bridge VC-231G VC-234G VDSL2 Introduction Product Overview Product Positioning Hardware Introduction Product Features Product Benefits Applications Product Comparison Appendix

More information

Enterprise Network Test Strategies for Network Availability and Performance. A Sitaramaiah Director Fluke Networks India

Enterprise Network Test Strategies for Network Availability and Performance. A Sitaramaiah Director Fluke Networks India Enterprise Network Test Strategies for Network Availability and Performance A Sitaramaiah Director Fluke Networks India 1 Why is Enterprise Network Testing becoming increasingly important? IT is increasingly

More information

with its cables, connectors, Switches, Hubs and topologies

with its cables, connectors, Switches, Hubs and topologies Introduction to LAN www.mycsvtunotes.in with its cables, connectors, Switches, Hubs and topologies LAN Small interconnected computers or workstations within a building or small area up to 10 Kms. Small

More information

Competing Methodologies and Future Trend in Residential High-Speed Internet Access

Competing Methodologies and Future Trend in Residential High-Speed Internet Access Competing Methodologies and Future Trend in Residential High-Speed Internet Access Hung Nguyen, Ph.D. The Aerospace Corporation 15049 Conference Center Dr. Chantilly, VA 20151 A simple solution to the

More information

Valid from Telephone Approved date

Valid from Telephone Approved date Specification 1.0 Valid from 2010-12-01 Specification number/reference A85 Document owner Vidar Skovli Telephone +47 8107 7000 e-mail vidar.skovli@telenor.com Approved (sign) Torleif Bakken Approved date

More information

Lighting the copper. Rezes elérési hálózatok (a) fényes jövő előtt. Gergo Bander 12/Apr/2016

Lighting the copper. Rezes elérési hálózatok (a) fényes jövő előtt. Gergo Bander 12/Apr/2016 Lighting the copper Rezes elérési hálózatok (a) fényes jövő előtt Gergo Bander 12/Apr/2016 1 Giga Access on copper, a big potential to explore G.fast Super Vector VDSL2 ADSL2+ 2020 5GBB 2015 G.fast 2016

More information

Origins of G.fast and its Role in future FTTH deployments. Rob F.M. van den Brink - TNO

Origins of G.fast and its Role in future FTTH deployments. Rob F.M. van den Brink - TNO Origins of G.fast and its Role in future FTTH deployments Rob F.M. van den Brink - TNO 1 Origins of G.fast and its Role in future FTTH deployments Rob F.M. van den Brink - TNO 2 1. And suddenly there was

More information

IPLoC D2-POM - User Guide

IPLoC D2-POM - User Guide IPLoC D2-POM - User Guide Table of Content 3 Security Note 4 Quick Start Guide 5 Introduction 5 Overview 5 MoCA Coax Network - Example 6 Interface 7 Installing IPLoC D2-POM 7 Overview 7 Minimum installation

More information

Merging of spectral allocation plans and PSD masks for VDSL. Rob van den Brink, KPN Research

Merging of spectral allocation plans and PSD masks for VDSL. Rob van den Brink, KPN Research TITLE PROJECT Merging of spectral allocation plans and masks for VDSL VDSL SOURCE: Authors: Presented by: Supported by: Bas van den Heuvel, KPN Research Rosaria Persico, Telecom Italia Lab Rob van den

More information

24-Port VDSL2/ADSL2+ with 2-Port Gigabit TP/SFP Combo IP DSLAM

24-Port VDSL2/ADSL2+ with 2-Port Gigabit TP/SFP Combo IP DSLAM 24-Port VDSL2/ADSL2+ with 2-Port Gigabit TP/SFP Combo IP DSLAM Key Features DSL Interfaces 24 full-duplex VDSL2/ADSL2+ links via RJ21 (Telco-50) connector 24 corresponding POTS lines via RJ21 (Telco-50)

More information

CMTS JH-HE2086. Jinghong. Chongqing Jinghong High-Technology Co., Ltd.

CMTS JH-HE2086. Jinghong. Chongqing Jinghong High-Technology Co., Ltd. CMTS J-E206 R Jinghong Chongqing Jinghong igh-technology Co., td. copyright 2007 www.cqjinghong.com CMTS J-E206 Overview J-E206 is a highly integrated DOCSIS compatible CMTS designed for cost sensitive

More information

2,5 and 5GBASE-T A Study of Development and Deployment. White Paper January 2017

2,5 and 5GBASE-T A Study of Development and Deployment. White Paper January 2017 2,5 and 5GBASE-T A Study of Development and Deployment White Paper January 2017 For more than fifteen years, Category 5e cabling has provided a robust channel for 100BASE-TX and 1000BASE-T to operate.

More information

VIAVI Seeker D Lite. Data Sheet. Shielding Integrity Testing Kit A Trilithic Series Leakage Solution. Overview. Key Features. In-Home Leakage Detector

VIAVI Seeker D Lite. Data Sheet. Shielding Integrity Testing Kit A Trilithic Series Leakage Solution. Overview. Key Features. In-Home Leakage Detector Data Sheet VIAVI Seeker D Lite Shielding Integrity Testing Kit A Trilithic Series Leakage Solution VIAVI Solutions Overview Mitigation of signal leakage within the subscriber premises is essential for

More information

Link Segment IEEE Mb/s Single Twisted Pair Ethernet Study Group Chris DiMinico MC Communications/Panduit

Link Segment IEEE Mb/s Single Twisted Pair Ethernet Study Group Chris DiMinico MC Communications/Panduit Link Segment IEEE 802.3 10 Mb/s Single Twisted Pair Ethernet Study Group hris DiMinico M ommunications/panduit cdiminico@ieee.org 1 Purpose Scope Initiate discussion(s) on 10 Mb/s Single Twisted Pair Ethernet

More information

Evaluation of the European SDSL Test Loop Insertion Losses

Evaluation of the European SDSL Test Loop Insertion Losses ETSI STC TM6 TD 18 1(5) Project: Title: SDSL Evaluation of the European SDSL Test Loop Insertion Losses Source: Authors: Contact: FTW Gernot Schmid, Tomas Nordström Tomas Nordström Forschungszentrum Telekommunikation

More information

NEWS. What s the difference between Cable and DSL broadband access? Part 2

NEWS. What s the difference between Cable and DSL broadband access? Part 2 PO Box 3561 El Paso, TX 79923-3561 NEWS www.kint98.com What s the difference between Cable and DSL broadband access? Part 2 Major technological differences produce roughly equivalent Internet performance

More information

Extending Ethernet over 2-wire Copper Networks

Extending Ethernet over 2-wire Copper Networks Extending Ethernet over 2-wire Copper Networks Executive Summary To improve the efficiency of industrial automation systems, many operators are considering the possibility of IP upgrades to provide centralised

More information

Broadband Over Existing Cable in Hotels

Broadband Over Existing Cable in Hotels White Paper Table of Contents Coax Cable Plant for MATV or Broadband 3 Cable Topology 4 DOCSIS Summary 6 VDSL2 over Telephone wire for Dedicated Broadband 7 Cable Topology 8 VDSL2 Summary 8 Broadband Over

More information

SPECIFICATION PTC 274:2016 REQUIREMENTS FOR CONNECTION OF CPE TO THE SPARK VDSL2 NETWORK

SPECIFICATION PTC 274:2016 REQUIREMENTS FOR CONNECTION OF CPE TO THE SPARK VDSL2 NETWORK SPECIFICATION PTC 274:2016 REQUIREMENTS FOR CONNECTION OF CPE TO THE SPARK VDSL2 NETWORK Spark New Zealand March 2016 March 2016 2/17 PTC274 CONTENTS Spark Disclaimer 4 1. INTRODUCTION 5 1.1. Purpose of

More information

DISTRIBUTION AMPLIFIER SYSTEMS

DISTRIBUTION AMPLIFIER SYSTEMS 99984 DISTRIBUTION AMPLIFIER SYSTEMS 99984 SYSTEM SALIENT FEATURES 128 differential inputs 16 differential input cables with 26-pin HD connectors 896 buffered, SE outputs with ground sense (seven groups

More information

AuroraPresto. A Revolution in DSL Testing. xdsl. the complete test tool for DSL technologies

AuroraPresto. A Revolution in DSL Testing. xdsl. the complete test tool for DSL technologies AuroraPresto A Revolution in DSL Testing xdsl the complete test tool for DSL technologies 7. Application layer test HTTP TCP/IP xdsl a multilayer technology 6. IP layer end-point test 5. PPP authentication

More information

Prequalification of VDSL2 Customers for G.fast Services

Prequalification of VDSL2 Customers for G.fast Services 217 25th European Signal Processing Conference (EUSIPCO) Prequalification of VDSL2 Customers for G.fast Services Driton Statovci, Martin Wolkerstorfer, and Sanda Drakulić Institute of Telecommunications,

More information

Yuna Shin Leviton Network Solutions

Yuna Shin Leviton Network Solutions Y Yuna Shin Leviton Network Solutions Presenter Bio Yuna Shin Senior Product Manager, Copper Leviton Network Solutions Bothell, WA U.S.A. Manages Leviton's extensive selection of Category 6A, 6, and 5e

More information

SAE J2931 test plan: PLC Testing Results. Tim Godfrey Arindam Maitra John Halliwell Daniel Foster John Harding Satish Rajagopalan

SAE J2931 test plan: PLC Testing Results. Tim Godfrey Arindam Maitra John Halliwell Daniel Foster John Harding Satish Rajagopalan SAE J2931 test plan: PLC Testing Results Tim Godfrey Arindam Maitra John Halliwell Daniel Foster John Harding Satish Rajagopalan 12-14-2011 Introduction SAE J2931 test plan (S316) was developed to test

More information

E3-E4 (CFA) EPON & GPON. For BSNL internal circulation only

E3-E4 (CFA) EPON & GPON. For BSNL internal circulation only E3-E4 (CFA) EPON & GPON AGENDA Limits of Present Access network. Passive Optical Network EPON / GEPON GPON Architecture PON Topology and services Conclusion PRESENT ACESS N/W ISDN HDSL ADSL ADSL2+ VDSL

More information

AP58GV3. Wireless Bridge. Last edited: Jim B 1/14/2019 Created: jim b

AP58GV3. Wireless Bridge. Last edited: Jim B 1/14/2019 Created: jim b AP58GV3 Wireless Bridge Introduction AP58GV3 is a 5G wireless bridge developed by Optiview for CCTV surveillance equipment. It is an easy-to-use yet delivers a complete CCTV solution for creating highly

More information

Broadband Communication 81

Broadband Communication 81 Broadband Communication 81 VDSL2 Router GEPON ONU GEPON OLT VDSL2 ID DSLAM EPL-2000 0 82 Broadband Communication Enjoy a Triple Play Networking Trend in xdsl Technology Several types of DSL technology

More information

ITU - Telecommunication Standardization Sector. G.fast: Far-end crosstalk in twisted pair cabling; measurements and modelling ABSTRACT

ITU - Telecommunication Standardization Sector. G.fast: Far-end crosstalk in twisted pair cabling; measurements and modelling ABSTRACT ITU - Telecommunication Standardization Sector STUDY GROUP 15 Temporary Document 11RV-22 Original: English Richmond, VA. - 3-1 Nov. 211 Question: 4/15 SOURCE 1 : TNO TITLE: G.ast: Far-end crosstalk in

More information