CCU. Command Control Unit

Size: px
Start display at page:

Download "CCU. Command Control Unit"

Transcription

1 CCU Command Control Unit

2 Table of Contents Introduction... 3 General Description... 3 Functions and Purposes... 3 Hardware... 4 SBFE 48V - B2GD SBFE 24V - B21D ISCA 48V - B21D ISCA 24V - B21D All Rights Reserved. Passing and copying of this document or part of it, use and communication of its contents is not permitted without authorization. Ansaldo STS.

3 Introduction Command Control Unit (CCU) The CCU platform is designed to provide a cost-effective SIL4 solution for Railway Applications in distributed, centralized (multi-station) or combined environments, where it acts as vital concentrator of field devices in a certain area or in an individual station of a multi-station system. General Description The CCU is based on 2oo2HR (2 out of 2 hot redundancy) type redundant architecture with vital Watch-dog. It makes use of Ethernet interfaces to CIU and RS-485 serial interfaces to FDC, these latter interfaces both with copper link and in part with remote optic fibre link. Processing units, interfacing units and all communication lines are redundant for availability. The 2oo2HR structure is physically implemented by two independent and galvanic isolated processing sections (one in Normal role and the other in Reserve role); only one of the two Sections acts as system Master, whereas the other one will act as Slave. Each section consists of a pair of processors (referred to as Replica A and Replica B) in 2oo2 architecture, operating in parallel and, when necessary, aligning via proper synchronisations. In this way input data are processed in parallel, and outputs will be correctly driven only if the results processed Replica A Replica A Normal Section Replica B Replica B Reserve Section by the two Replicas are identical, otherwise a diversity condition is present and the CCU section will be set irreversibly into safe state. Functions and Purposes CCU operates as Gateway between CIU and FDCs and runs the following tasks: Acquire from the Central Interlocking Unit the commands for the FDCs via Ethernet link; Forward commands to FDCs via RS485 serial lines and/or optic fibre lines; Acquire from FDCs the controls for CIU via RS485 serial lines and/or optic fibre lines; Forward controls to CIU via Ethernet link; Check regular system operation; Provide CIU with diagnostic information on the operating state of connections and CCU; Implement transparent hot redundancy mechanisms to Central Post and Peripheral Post; Provide the operating state of the managed devices. Innovations in comparison with previous product generations are the following: Interface to CIU is implemented via Ethernet 100 base-t instead of HDLC 2Mbps; The number of FDCs which can be driven by a CCU is 992 (124 for each serial line for a total of 8 serial lines) instead of 42 FDCs on one line of the previous Area Controller. Generic HW/SW platform may also be used for other functions like for instance Wayside Message Server (WMS) and Central Message Radio Server (CMRS). 3

4 Hardware From a HW point of view, the CCU Unit is based on two redundant boards: SBFE, processing board with 2oo2 fail-safe technology; ISCA, splitter board for external Ethernet connections, allowing to put two homologous Ethernet links of the redundant SBFE boards in common with a single connection towards Supervision/Central Post ISCA module Normal Section 2 - SBFE module Normal Section 3 - SBFE module Reserve Section 4 - ISCA module Reserve Section The CCU unit consists of two pairs of SBFE-ISCA boards: one pair runs the Normal function whereas the other one runs the Reserve function. These two pairs are only provided for availability purposes. These boards come in two mounting versions, which only differ for the operating voltage. Unit Power Supply Part Number SBFE +48 Vdc B2GD SBFE 24V +24 Vdc B21D ISCA +48 Vdc B21D ISCA 24V +24 Vdc B21D CCU can be hosted in different configurations of racks with backplane: BCAN, BCDS each of which features other functions since hosting also other boards, however the section dedicated to CCU is identical for all of them. 4 All Rights Reserved. Passing and copying of this document or part of it, use and communication of its contents is not permitted without authorization. Ansaldo STS.

5 Command Control Unit (CCU) SBFE 48V - B2GD SBFE module is a CCU unit implemented with 2oo2 architecture and suitable for communicating with the WSP Vital Core. It can be used as a traditional Area Controller, i.e.: management of a Peripheral Post and communication to the Central Post, or as Station Controller : SBFE can actually perform Central Post functions for small sized stations. The new generation rack (84 TE Standard Rack) allows to host 3 pairs of Area Controllers (Normal + Reserve), for a total of 6 SBFE modules. This configuration allows to manage: 128 FDC per RS-485 serial line; 8 Area Controllers (single, in redundant pairs); 3 redundant pairs (N. CoE 3072). The SBFE module was designed as safety board with high computing capacity and connectivity with its surrounding environment (i.e.: Ethernet and RS-485). Therefore, depending on the installed SW application, module applications can be multiple (e. g.: station controller, communication gateway to SCC, etc.). The SBFE module performs the following functions: Diagnostic / configuration / software download through USB serial lines. Front panel diagnostic LED management. Watch dog refresh and test functions. Data Logging and Event Recording. Serial link speed management. Temperature sensor test and management. When used as CCU, SBFE module communicates with: 1. The I/O boards dedicated to each FDC through four asynchronous redundant RS485 lines. 2. The Central Post through two redundant Ethernet links. Front View 5

6 General Features Product name: Part number: SBFE Module (48V) B2GD Composition: File SW: First installation year: Customer Part Number: Supply Characteristics Supply voltage [V] min: 36 nom: 48 max: 72 Absorbed current [A] min: nom: 0.2 max: Power [W] standby: normal working: 9.6 max: Overvoltage/overcurrent protection inner circuit(s): OV1 Overvoltage/overcurrent protection inner circuit(s) for atmospheric discharges: EN Reliability, Availability and Maintainability MTBF [h]: max MTTR [h]: Test result evaluation criteria: Obsolescence: Product Technology NO Programming languages: HW used: COTS, proprietary HW Mechanical Features Size ( l x h x d ) [mm]: x x 220 Format front panel or cabinet: 6U x 7TE Front panel color: RAL7032 Weight [Kg]: 2.35 Installation constraints: Used materials: Environmental and Climatic Features IP degree: Working temperature [ C]: Storage temperature [ C]: Vibrations: Altitude [m]: 2000 Relative humidity: 40% 70% (@ 30 C) I/O Interface Interface typology: Interface connector typology: Interface communication protocol: Interfacing to signalling plants and interface typology: Bus typology: Diagnostics Internal diagnostic: 8 x RS-485 serial lines N/R, 4 x 10/100baseT Ethernet line (not safety related). 4 x RJ-45, 4 x USB Type B, 2 x Rear connectors DIN41612 type C male to 96-way. ASTS Master/Slave (serial links) Ethernet (other communication) RS-485, Ethernet. USB Type B Number and typology of recordable events: Local diagnostic: Via USB Centralized diagnostic: Maintenance tools: D360 Regulations and Norms Compliance: Safety EN (EN /A1, EN /A2), EN 50129, EN , EN SIL degree: Safety certification: CENELEC ENV Interoperability STI applicable: Supplier CE conformity declaration: Conformity CE certification: EN Notified organism which has performed the verifying procedure: Technical features subject to variation without notice. 6 All Rights Reserved. Passing and copying of this document or part of it, use and communication of its contents is not permitted without authorization. Ansaldo STS.

7 Command Control Unit (CCU) SBFE 24V - B21D SBFE module is a CCU unit implemented with 2oo2 architecture and suitable for communicating with the WSP Vital Core. It can be used as a traditional Area Controller, i.e.: management of a Peripheral Post and communication to the Central Post, or as Station Controller : SBFE can actually perform Central Post functions for small sized stations. The new generation rack (84 TE Standard Rack) allows to host 3 pairs of Area Controllers (Normal + Reserve), for a total of 6 SBFE modules. This configuration allows to manage: 128 FDC per RS-485 serial line; 8 Area Controllers (single, in redundant pairs); 3 redundant pairs (N. CoE 3072). The SBFE module was designed as safety board with high computing capacity and connectivity with its surrounding environment (i.e.: Ethernet and RS-485). Therefore, depending on the installed SW application, module applications can be multiple (e. g.: station controller, communication gateway to SCC, etc.). The SBFE module performs the following functions: Diagnostic / configuration / software download through USB serial lines. Front panel diagnostic LED management. Watch dog refresh and test functions. Data Logging and Event Recording. Serial link speed management. Temperature sensor test and management. When used as CCU, SBFE module communicates with: 1. The I/O boards dedicated to each FDC through four asynchronous redundant RS485 lines. 2. The Central Post through two redundant Ethernet links. Front View 7

8 General Features Product name: Part number: SBFE Module (24V) B21D Composition: File SW: First installation year: Customer Part Number: Supply Characteristics Supply voltage [V] min: ~ 19.2 nom: 24 max: ~ 28.8 Absorbed current [A] min: nom: max: Power [W] standby: normal working: 9.6 max: Overvoltage/overcurrent protection inner circuit(s): OV1 Overvoltage/overcurrent protection inner circuit(s) for atmospheric discharges: EN Reliability, Availability and Maintainability MTBF [h]: max MTTR [h]: Test result evaluation criteria: Obsolescence: Product Technology NO Programming languages: HW used: COTS, proprietary HW Mechanical Features Size ( l x h x d ) [mm]: x x 220 Format front panel or cabinet: 6U x 7TE Front panel color: RAL7032 Weight [Kg]: 2.35 Installation constraints: Used materials: Environmental and Climatic Features IP degree: Working temperature [ C]: Storage temperature [ C]: Vibrations: Altitude [m]: 2000 Relative humidity: 40% 70% (@ 30 C) I/O Interface Interface typology: Interface connector typology: Interface communication protocol: Interfacing to signalling plants and interface typology: Bus typology: Diagnostics Internal diagnostic: 8 x RS-485 serial lines N/R, 4 x 10/100baseT Ethernet line (not safety related). 4 x RJ-45, 4 x USB Type B, 2 x Rear connectors DIN41612 type C male to 96-way. ASTS Master/Slave (serial links) Ethernet (other communication) RS-485, Ethernet. USB Type B Number and typology of recordable events: Local diagnostic: Via USB Centralized diagnostic: Maintenance tools: D360 Regulations and Norms Compliance: Safety EN (EN /A1, EN /A2), EN 50129, EN , EN SIL degree: Safety certification: CENELEC ENV Interoperability STI applicable: Supplier CE conformity declaration: Conformity CE certification: EN Notified organism which has performed the verifying procedure: Technical features subject to variation without notice. 8 All Rights Reserved. Passing and copying of this document or part of it, use and communication of its contents is not permitted without authorization. Ansaldo STS.

9 ISCA 48V - B21D The ISCA module is a communication bridge between the SBFE module and other connected equipment. Command Control Unit (CCU) 3D view Front View The ISCA module provides the following functions: 2 x RS-485 serial bus to and from fibre optic interfaces, to allow the communication with remote equipment; ethernet multiplexer, to mask the redundant SBFE architecture to the connected equipment. 9

10 General Features Product name: ISCA Module (48V) Mechanical Features Size ( l x h x d ) [mm]: x x 220 Part number: B21D Composition: File SW: First installation year: 2012 Customer Part Number: Format front panel or cabinet: 6U x 7TE Front panel color: RAL7032 Weight [Kg]: Installation constraints: Used materials: Supply Characteristics Supply voltage [V] min: 38 nom: 48 max: 56 Absorbed current [A] min: nom: 0.12 max: Power [W] standby: normal working: 6 max: Overvoltage/overcurrent protection inner circuit(s): OV1 Overvoltage/overcurrent protection inner circuit(s) for atmospheric discharges: EN Reliability, Availability and Maintainability MTBF [h]: max MTTR [h]: Test result evaluation criteria: Obsolescence:: Product Technology Programming languages: Environmental and Climatic Features IP degree: Working temperature [ C]: Storage temperature [ C]: Vibrations: Altitude [m]: 2000 Relative humidity: 40% 70% (@ 30 C) I/O Interface Interface typology: Interface connector typology: Interface communication protocol: Interfacing to signalling plants and interface typology: Bus typology: Diagnostics RJ-45, SC duplex ASTS Master/Slave (serial links) RS485, Ethernet. Internal diagnostic: Number and typology of recordable events: Local diagnostic: Centralized diagnostic: Maintenance tools: HW used: COTS, proprietary HW Regulations and Norms Compliance: EN , EN , EN 50129, EN Safety SIL degree: Safety certification: Interoperability STI applicable: Supplier CE conformity declaration: Conformity CE certification: EN Notified organism which has performed the verifying procedure: Technical features subject to variation without notice. 10 All Rights Reserved. Passing and copying of this document or part of it, use and communication of its contents is not permitted without authorization. Ansaldo STS.

11 Command Control Unit (CCU) ISCA 24V - B21D The ISCA module 24V is a communication bridge between the SBFE module and other connected equipment. 3D view Front View The ISCA module 24V provides the following functions: 2 x RS-485 serial bus to and from fibre optic interfaces, to allow the communication with remote equipment; ethernet multiplexer, to mask the redundant SBFE architecture to the connected equipment. 11

12 General Features Product name: ISCA Module (24V) Mechanical Features Size ( l x h x d ) [mm]: x x 220 Part number: B21D Composition: File SW: First installation year: 2012 Customer Part Number: Format front panel or cabinet: 6U x 7TE Front panel color: RAL7032 Weight [Kg]: Installation constraints: Used materials: Supply Characteristics Supply voltage [V] min: ~ 19.2 nom: 24 max: ~ 28.8 Absorbed current [A] min: nom: max: Power [W] standby: normal working: 9.6 max: Overvoltage/overcurrent protection inner circuit(s): OV1 Overvoltage/overcurrent protection inner circuit(s) for atmospheric discharges: EN Reliability, Availability and Maintainability MTBF [h]: max MTTR [h]: Test result evaluation criteria: Obsolescence:: Product Technology Programming languages: Environmental and Climatic Features IP degree: Working temperature [ C]: Storage temperature [ C]: Vibrations: Altitude [m]: 2000 Relative humidity: 40% 70% (@ 30 C) I/O Interface Interface typology: Interface connector typology: Interface communication protocol: Interfacing to signalling plants and interface typology: Bus typology: Diagnostics RJ-45, SC duplex ASTS Master/Slave (serial links) RS485, Ethernet. Internal diagnostic: Number and typology of recordable events: Local diagnostic: Centralized diagnostic: Maintenance tools: HW used: COTS, proprietary HW Regulations and Norms Compliance: EN , EN , EN 50129, EN Safety SIL degree: Safety certification: Interoperability STI applicable: Supplier CE conformity declaration: Conformity CE certification: EN Notified organism which has performed the verifying procedure: Technical features subject to variation without notice. 12 All Rights Reserved. Passing and copying of this document or part of it, use and communication of its contents is not permitted without authorization. Ansaldo STS.

13 Command Control Unit (CCU) Notes 13

14 14 All Rights Reserved. Passing and copying of this document or part of it, use and communication of its contents is not permitted without authorization. Ansaldo STS.

15 Property of Ansaldo STS SpA, 2015, all rights reserved. The copying, reproduction and use of this work in any form whatsoever is forbidden without the written authorization of Ansaldo STS SpA.

16 Ansaldo STS SpA Via Paolo Mantovani Genoa - Italy

Components Power Supplies and Converters TALIS48 AC/DC Converter Generic Product Catalog

Components Power Supplies and Converters TALIS48 AC/DC Converter Generic Product Catalog Components Power Supplies and Converters TALIS48 AC/DC Converter Generic Product Catalog Power Supplies and Converters - TALIS48 AC/DC Converter Table of Contents Introduction TALIS power supply module...

More information

Wayside Standard Platform

Wayside Standard Platform Wayside Standard Platform Main features Wayside Standard Platform (WSP) is the standard platform designed by Ansaldo STS for all vital wayside applications. WSP is a system that can manage vitally, from

More information

BPT-2G Balise Programmer and Tester

BPT-2G Balise Programmer and Tester BPT-2G Balise Programmer and Tester Supporting tool for: installation and maintenance of standard and reduced-size Eurobalise balise groups, of any version, complying with Eurobalise specifications; diagnostics

More information

Spark gap surge arrester for direct current OLE line

Spark gap surge arrester for direct current OLE line Spark gap surge arrester for direct current OLE line System suitable to ensure surge protection to equipment and devices connected to (Overhead Line Electrification) OLE lines operating under direct current.

More information

Components Audiofrequency Track Circuit Management Generic Product Catalog

Components Audiofrequency Track Circuit Management Generic Product Catalog Components Generic Product Catalog Table of Contents CBDAC Audiofrequency Track Circuit... 1 PP - Audiofrequency Track Circuits - Railway Applications - B90A.000001... 3 PP - Audiofrequency Track Circuits

More information

Cardfiles (MicroLok II Applications)

Cardfiles (MicroLok II Applications) Wayside Signaling System Ansaldo STS USA The cardfiles used in MicroLok II systems accommodate the full range of user system applications and PCB configurations in a single rack-mount unit. Unlike earlier

More information

Ovation Ethernet Link Controller Module Data Sheet

Ovation Ethernet Link Controller Module Data Sheet Ovation Ethernet Link Controller Module Features: Provides native Ethernet connectivity capability at the I/O level Enables faster, more efficient integration of robust data from third-party devices Dedicated

More information

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety

More information

Webdom Datalogger 1.5

Webdom Datalogger 1.5 PV plants - From W to MW Energy monitoring from a single device in a simple and intuitive way. Complete solution for monitoring PV plants, from W to MW Video cameras module. GENERAL DESCRIPTION INFORMATION

More information

MESR Port Industrial Modbus Gateway. Specifications Power. MESR424_r000_2913ds

MESR Port Industrial Modbus Gateway. Specifications Power. MESR424_r000_2913ds MESR424 4-Port Industrial Modbus Gateway MESR424_r000_2913ds Ethernet-Enable Modbus RS-232/422/485 MODBUS TCP, ASCII & RTU Modbus Flexibility Serial & Ethernet, Masters & Slaves Modbus Messaging Priority

More information

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output Product datasheet Characteristics XPSMF4000 Preventa safety PLC compact - Safe Ethernet Main Range of product Product or component type Safety module name Safety module application Preventa Safety automation

More information

PRODUCT OVERVIEW. Redundant CPUs. High speed µs processing. Redundant power supplies. Large 62K-word program and 24Kword data memory capacity

PRODUCT OVERVIEW. Redundant CPUs. High speed µs processing. Redundant power supplies. Large 62K-word program and 24Kword data memory capacity PRODUCT OVERVIEW ` CVM1 Series The CVM1D Duplex system s redundancy is a new option in Omron s large controllers. Two redundant CPUs and power supplies ensure that processes will continue operation when

More information

GS Dupline Profinet Gateway. Benefits. Description

GS Dupline Profinet Gateway. Benefits. Description Dupline Profinet Gateway Benefits Profinet gateway with the function as a slave Up to 7 master generators can be connected via the HS RS485 bus (side connector) All Dupline signals from the master generators

More information

AS-i 3.0 PROFINET-Gateways with integrated Safety Monitor

AS-i 3.0 PROFINET-Gateways with integrated Safety Monitor AS-i 3.0 PROFI Gateways with Master, 1 PROFI Slave Up to 32 release circuits up to 6 safe output circuits on the Monitor safe relays or fast electronic safe outputs up to 32 independent AS-i outputs Multiple

More information

Programmable Set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable Set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type designation Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100

More information

317FX-N. Phone: Fax: Web: -

317FX-N. Phone: Fax: Web:  - THE INDUSTRIAL NETWORK COMPANY 317FX-N The N-TRON 317FX-N, an unmanaged Industrial Ethernet switch, is designed for use in industrial data acquisition, control, and Ethernet I/O applications. The rugged

More information

x86 2U 19-inch rackmount computers with 2nd Gen Intel Celeron or Core i7 CPU, 6 Gigabit Ethernet ports, and 2 PCI expansion slots

x86 2U 19-inch rackmount computers with 2nd Gen Intel Celeron or Core i7 CPU, 6 Gigabit Ethernet ports, and 2 PCI expansion slots DA-682A Series x86 2U 19-inch rackmount computers with 2nd Gen Intel Celeron or Core i7 CPU, 6 Gigabit Ethernet ports, and 2 PCI expansion slots Features and Benefits EN 50121-4 compliant for railway wayside

More information

VCL-TP, Teleprotection Equipment

VCL-TP, Teleprotection Equipment VCL-TP, Teleprotection Equipment Data Sheet Copyright: Valiant Communications Limited. - 2013 1 Product Overview VCL-TP, Teleprotection Equipment is an extremely reliable and flexible product that offers

More information

114FX6. Phone: Fax: Web: -

114FX6. Phone: Fax: Web:  - THE INDUSTRIAL NETWORK COMPANY 114FX6 PRODUCT FEATURES Compact, Space Saving Package Full IEEE 802.3 Compliance Eight 10/100BaseTX RJ-45 Ports Six 100BaseFX Ports, ST or SC Style Unmanaged Operation Extended

More information

Legacy Serial. Legacy Serial Redundant Ring Ethernet Extender DDW-222. High Speed Ethernet extension over copper. Configuration and diagnostics

Legacy Serial. Legacy Serial Redundant Ring Ethernet Extender DDW-222. High Speed Ethernet extension over copper. Configuration and diagnostics Redundant Ring Ethernet Extender High Speed Ethernet extension over copper The is an Industrial Ethernet SH extender with support for redundant rings. The redundant protocol can be used either on the SH

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term Characteristics Modbus TCPIP diagnostic expansion module with screw term Main Range of product Product or component type Device short name [Us] rated supply voltage Complementary Power dissipation in W

More information

316TX-N. Phone: Fax: Web: -

316TX-N. Phone: Fax: Web:  - THE INDUSTRIAL NETWORK COMPANY 316TX-N The N-TRON 316TX-N, an unmanaged Industrial Ethernet switch, is designed for use in industrial data acquisition, control, and Ethernet I/O applications. The rugged

More information

Compact multiprotocol I/O module for Ethernet 16 configurable digital channels pnp inputs / outputs 2 A FGEN-XSG

Compact multiprotocol I/O module for Ethernet 16 configurable digital channels pnp inputs / outputs 2 A FGEN-XSG Input diagnostics per port Output diagnostics per channel Two freely selectable digital signals per port 7/8", 4-pin, for power supply Fibre-glass reinforced PA6 housing Vibration and shock-resistant Encapsulated

More information

PA ROUTERS. The following criteria can be applied when choosing the network transition:

PA ROUTERS. The following criteria can be applied when choosing the network transition: PA ROUTERS To create a smooth network transition between PROFIBUS DP and PROFIBUS PA, the SIMATIC product range offers two versions: the DP/PA coupler and the PA link. The following criteria can be applied

More information

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel VCL-TP, Teleprotection Equipment With Trip Counter Display Panel Data Sheet Copyright: Valiant Communications Limited. 2008-2014 1 Product Overview VCL-TP, Teleprotection Equipment is an extremely reliable

More information

308FX2-N. Phone: Fax: Web:

308FX2-N. Phone: Fax: Web: THE INDUSTRIAL NETWORK COMPANY 308FX2-N The N-TRON 308FX2-N, an unmanaged Industrial Ethernet switch, is designed for use in industrial data acquisition, control, and Ethernet I/O applications. The rugged

More information

Compact multiprotocol I/O module for Ethernet 16 digital pnp inputs FGEN-IM

Compact multiprotocol I/O module for Ethernet 16 digital pnp inputs FGEN-IM Multiprotocol I/O module for the Ethernet protocols Modbus TCP, Ether- Net/IP and PROFINET PROFINET supports Fast Start-Up (FSU) EtherNet/IP supports QuickConnect (QC) Integrated Ethernet switch FDT/DTM

More information

PSI-MODEM-SHDSL/SERIAL Copper Extender

PSI-MODEM-SHDSL/SERIAL Copper Extender PSI-MODEM-SHDSL/SERIAL Copper Extender perle.com /products/serial-extenders/psi-modem-shdsl-serial-extender.shtml RS232/422/485 over copper wire Transmit serial data up to 20km [12.4 mi] Two SHDSL ports

More information

PSI-MODEM-SHDSL/SERIAL

PSI-MODEM-SHDSL/SERIAL PSI-MODEM-/SERIAL -SERIAL permanent line modem Data sheet 104460_en_02 PHOENIX CONTACT 2011-12-06 1 Description The industrial SERIAL permanent line modem enables broadband networking of serial devices

More information

LION SAFE Remote I/O System. LÜTZE TRANSPORTATION GMBH Dimitrios Koutrouvis V00

LION SAFE Remote I/O System. LÜTZE TRANSPORTATION GMBH Dimitrios Koutrouvis V00 Page 1 LÜTZE TRANSPORTATION GMBH Dimitrios Koutrouvis V00 Actual Market Situation New Safety Requirements from Standards and Authorities Governance European Union (EU) ==> European Railway Agency (ERA)

More information

305FX-N. Phone: Fax: Web:

305FX-N. Phone: Fax: Web: THE INDUSTRIAL NETWORK COMPANY 305FX-N The N-TRON 305FX is an unmanaged, five port Industrial Ethernet Switch. It is housed in a ruggedized DIN-RAIL enclosure and is designed for use in industrial data

More information

Bus Connection Unit 560BCU04

Bus Connection Unit 560BCU04 Bus Connection Unit 560BCU04 Application The Bus Connection Unit 560BCU04 R0001 is designed to make the RTU560s TSI, TSO, Alarm and Warning signals accessible to the outside. By using the bus connection

More information

Interlocking Solutions. MicroLok II

Interlocking Solutions. MicroLok II Interlocking Solutions 1 Wayside Control System The Ansaldo STS Wayside Control System for mass transit, metro, main lines and freight applications, combines the functions of railway signalling and control

More information

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves switch via safe Up to 32 release circuits up

More information

IMIO100 IMIO105. DDC controllers. Summary

IMIO100 IMIO105. DDC controllers. Summary IMIO100 IMIO105 DDC controllers Summary DDC (Direct digital control) controller IMIO100 and IMIO105 are free programmable process stations with ARM Cortex M4 processor and OS FreeRTOS. They contain one

More information

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018

More information

The PROFIBUS and PROFINET Company. COMbricks Modules. Copyright 2013 PROCENTEC. All rights reserved.

The PROFIBUS and PROFINET Company. COMbricks Modules. Copyright 2013 PROCENTEC. All rights reserved. Modules SCOPE Repeater Module Name 1 Channel RS 485 SCOPE Repeater Type 1 Order code 101 201210 Description 1 Channel RS 485 PROFIBUS SCOPE repeater module with integrated quality oscilloscope for 12 Mbps

More information

Compact multiprotocol I/O module for Ethernet 16 digital pnp inputs FGEN-IM

Compact multiprotocol I/O module for Ethernet 16 digital pnp inputs FGEN-IM Multiprotocol I/O Module for the Ethernet protocols Modbus TCP, Ether- Net/IP and PROFINET PROFINET supports Fast Start-Up (FSU) EtherNet/IP supports QuickConnect (QC) Integrated Ethernet Switch FDT/DTM

More information

Application RTU560 RJ45 RJ45. Management. Switch RJ45 RJ45. Switch 560NMS34 SDSL. Data Sheet Switch 560NMS34. Port 1. Port 2. Port 3.

Application RTU560 RJ45 RJ45. Management. Switch RJ45 RJ45. Switch 560NMS34 SDSL. Data Sheet Switch 560NMS34. Port 1. Port 2. Port 3. Switch 560NMS34 Application The RTU component 560NMS34 is a managed plug and play Layer2-switch providing four Fast auto-negotiating RJ45-ports with auto MDI/X (Automatic Crossover Detection and Correction)

More information

ADA User manual ADA RS-485 / RS-422 to RS-232 Converter. 1 io_ada-4010_v3.22_en. Copyright CEL-MAR sp.j.

ADA User manual ADA RS-485 / RS-422 to RS-232 Converter. 1 io_ada-4010_v3.22_en. Copyright CEL-MAR sp.j. User manual ADA-4010 RS-485 / RS-422 to RS-232 Converter Copyright 2001-2017 CEL-MAR spj 1 io_ada-4010_v322_en Contents 1 GENERAL INFORMATION 3 11 WARRANTED INFORMATION 3 12 GENERAL CONDITIONS FOR SAFE

More information

Installation Guide Controller Series E130/E230/E430

Installation Guide Controller Series E130/E230/E430 Controller Series E0/0/0 Installation Guide Controller Series E0/E0/E0 Products E0-DP E0-DP E0-DP Content IMPORTANT NOTES FOR E0/E0/E0 SERIES CONTROLLERS... SYSTEM OVERVIEW... E0 SERIES FUNCTION AND WIRING...

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

MODULAR PROCESS AND QUALITY CONTROL SYSTEM FOR MACHINE TOOLS

MODULAR PROCESS AND QUALITY CONTROL SYSTEM FOR MACHINE TOOLS MODULAR PROCESS AND QUALITY CONTROL SYSTEM FOR MACHINE TOOLS Description of the system BLÚ includes, and surpasses, all the machine tool monitoring and/or process control applications that MARPOSS has

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

AC-DC Converter REC K10

AC-DC Converter REC K10 Rectifier System for Telecom-, Industry- and Rail applications General Electrical Safety EN 60950, UL 94 Protection class 1 Pollution degree 2 Isolation primary secondary 3.75kVDC PFC Ventilation EN 6100-3-2,

More information

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

See instructions to download and install the latest version of LinkBoxLON and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

P3-RS Remote Slave Module

P3-RS Remote Slave Module P3-RS Rack with CPU Module Racks with P3-RS Modules The P3-RS is a full-featured, highperformance, Remote Slave module. Features include a line x 0 charactor LCD display and five communications ports

More information

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT DKG-210 UNIVERSAL INTERNET GATEWAY UNIT AC & DC SUPPLY VERSIONS DESCRIPTION The DKG-210 is designed for internet monitoring and control of industrial devices using different protocols through the RAINBOW

More information

XPSMCMDI Input expansion module with screw term

XPSMCMDI Input expansion module with screw term Characteristics 16 Input expansion module with screw term Main Range of product Product or component type Device short name Electrical connection [Us] rated supply voltage Number of inputs Number of outputs

More information

CSI 6300 SIS Overview

CSI 6300 SIS Overview Overview The Digital Overspeed Protection System is TÜV - certified according to IEC 61508:2010 and provides speed measurement and detection of rotational direction for rotating machines such as turbines,

More information

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21 Characteristics variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21 Main Range of product Product or component type Device application Device short name Variant Product destination Mounting

More information

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves

More information

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves

More information

MESR321. Vlinx Isolated Industrial Modbus Ethernet to Serial Gateway B&B ELECTRONICS PRODUCT INFORMATION

MESR321. Vlinx Isolated Industrial Modbus Ethernet to Serial Gateway B&B ELECTRONICS PRODUCT INFORMATION MESR321 Vlinx Isolated Industrial Modbus Ethernet to Serial Gateway Three-way Isolation Ethernet-Enable Modbus RS-232/422/485 MODBUS TCP, ASCII & RTU Modbus Flexibility Serial & Ethernet, Masters & Slaves

More information

AS-i 3.0 Sercos Gateways with integrated Safety Monitor

AS-i 3.0 Sercos Gateways with integrated Safety Monitor AS-i 3.0 Sercos Gateways with Safety on Sercos and Safe Link in one device up to 456 Devices Safely monitoring safety drives with Safety on Sercos 2 / 1 AS-i master, Sercos slave switch integrated (figure

More information

3500/92 Communication Gateway

3500/92 Communication Gateway 3500/92 Communication Gateway Description The 3500/92 Communication Gateway module provides extensive communication capabilities of all rack monitored values and statuses for integration with process control

More information

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3 Programmable multiprotocol Ethernet gateway for PROFINET, EtherNet/IP and Modbus TCP OPC-Server CODESYS V3 programmable acc.to IEC 61131-3 Ethernet and USB programming interface Protection type IP20 Integrated

More information

Technical Information Fieldgate SFG500

Technical Information Fieldgate SFG500 TI00029S/04/EN/10.16 71324508 Products Solutions Services Technical Information Fieldgate SFG500 Smart Ethernet/PROFIBUS gateway Parallel access to PROFIBUS networks Monitoring of PROFIBUS and HART device

More information

Programmable Set for Ethenet/IP in IP67 TI-BL67-PG-EIP-2

Programmable Set for Ethenet/IP in IP67 TI-BL67-PG-EIP-2 Type designation Ident no. 1545069 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100

More information

SD328AU68S2 motion control stepper motor drive - SD328 - <= 6.8 A

SD328AU68S2 motion control stepper motor drive - SD328 - <= 6.8 A Characteristics motion control stepper motor drive - SD328 -

More information

304TX-N. Phone: Fax: Web:

304TX-N. Phone: Fax: Web: THE INDUSTRIAL NETWORK COMPANY 304TX-N The N-Tron 304TX is an unmanaged four port Industrial Ethernet Switch. It is housed in a ruggedized DIN-RAIL enclosure and is designed for use in industrial data

More information

ComBricks Monitoring, Networking and Control

ComBricks Monitoring, Networking and Control PROCENTEC ComBricks Monitoring, Networking and Control ComBricks ComBricks is the first PROFIBUS and PROFINET based automation system that unites network components and permanent monitoring with ProfiTrace.

More information

Faults on the system Proximity switch connection technology:

Faults on the system Proximity switch connection technology: Speed monitor for connection to a base unit from the PNOZmulti modular safety system Approvals Unit features Monitoring of 2 independent axes Connection of 2 incremental encoders or 4 proximity switches

More information

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description I/O extension module, 4 digital relay outputs INTERFACE Data sheet 104834_en_01 PHOENIX CONTACT 2013-01-21 1 Description The RAD-DOR4-IFS I/O extension module can be used in conjunction with Radioline

More information

Loop-O9330 Fiber Optical Mux

Loop-O9330 Fiber Optical Mux Loop-O9330 Fiber Optical Mux Features Up to 16 E1 links and one 100Mbps ethernet link on one fiber Auto Laser Shutdown function is user configurable Supports 10/100M Ethernet Bridge plug-in card (Optional)

More information

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless

More information

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035 Meters and Energy Cost Allocation M-bus web server WTV676-HB6035 The web server reads out wireless or wired M-bus devices over Ethernet or the Internet using a browser. Power and connection for up to 20

More information

Models HP Z VR Backpack G1 Dock

Models HP Z VR Backpack G1 Dock Overview the HP Z VR Backpack G1 Workstation Models HP Z VR Backpack G1 Dock 2LM71AA Compatibility Docking Station HP Z VR Backpack G1 Dock Mobile Workstation HP Z VR Backpack G1 Workstation NOTE 1: The

More information

6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable

6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable 6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable Product ID: IES61002POE The IES61002POE 6-Port Industrial PoE+ switch lets you connect

More information

CPU module for zone 2 Series 9442/35

CPU module for zone 2 Series 9442/35 > Supports PROFIBUS DP, PROFINET, Modbus TCP and Ethernet/IP; incl. HART transmission > RS-485 (max. 12 Mbps) and Ethernet (max. 100 Mbps) interfaces > Extensive diagnostics based on NE 107 > Support of

More information

DVBus , and Multiplexer and demultiplexer assemblies for video channels USER MANUAL

DVBus , and Multiplexer and demultiplexer assemblies for video channels USER MANUAL DVBus 8050-16, 8050-24 and 8050-32 Multiplexer and demultiplexer assemblies for 16-32 video channels USER MANUAL 1. Description DVBus 8050 systems transmit 10-bit digitized video signals over one optical

More information

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3 Programmable multiprotocol Ethernet gateway for PROFINET, EtherNet/IP and Modbus TCP OPC-Server CODESYS V3 programmable acc.to IEC 61131-3 Ethernet and USB programming interface Protection type IP20 Integrated

More information

Compact Multiprotocol I/O Module for Ethernet 16 Universal Digital Channels, Configurable as PNP Inputs or 2 A Outputs TBEN-L4-16DXP

Compact Multiprotocol I/O Module for Ethernet 16 Universal Digital Channels, Configurable as PNP Inputs or 2 A Outputs TBEN-L4-16DXP PROFINET device, EtherNet/IP device or Modbus TCP slave Integrated Ethernet switch Supports 10 Mbps/100 Mbps 2x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass fiber reinforced housing Shock and

More information

Web interface BACnet/IP

Web interface BACnet/IP s 9 294 DESIGO PX Web interface BACnet/IP PXG3.W100 Local or remote operation of one or multiple PX automation station(s) via Desigo Touch Panels (TP) and standard web browser Connection via Ethernet Central

More information

Transportation Solutions LÜTZE Rail Technology. Product overview Control Technology

Transportation Solutions LÜTZE Rail Technology. Product overview Control Technology Transportation Solutions LÜTZE Rail Technology Product overview Control Technology Control Technology Remote I/O Module Ethernet/IP DIOLINE 20 Passenger Information System DIOSWITCH IP 67 Remote I/O Module

More information

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL 200 VA bis 3.120 VA 10 V bis 80 V 2 A bis 320 A NL AC, NL Series Interface overview RS-232 X USB X GPIB O LAN O System bus O Analog X Analog isolated O X Standard O Option / not available NL1V20C40 2-quadrant

More information

IntesisBox Modbus Server Panasonic

IntesisBox Modbus Server Panasonic IntesisBox Modbus Server - Panasonic Gateway for Panasonic ECO-i VRF and PAC-i system integration into Modbus Systems Master Up to 30 Outdoor units Up to 64 Indoor units Modbus TCP Master /EIA232 PA-AC-MBS-64/128

More information

CPCI-PS24 24V-Power Supply

CPCI-PS24 24V-Power Supply 24V-Power Supply Hardware Manual to Product I.2301.21 esd electronic system design gmbh Vahrenwalder Str. 207 30165 Hannover Germany http://www.esd.eu Phone: +49 (0) 511 3 72 98-0 Fax: +49 (0) 511 3 72

More information

B12-3U VMEbus PowerPC SBC

B12-3U VMEbus PowerPC SBC B12-3U VMEbus PowerPC SBC MPC823e/66MHz 1-slot VMEbus master/slave or busless 128MB DRAM, 32MB Flash, CompactFlash 10Mbit Ethernet 3 COMs, 3 CAN 1 M-Module slot CANopen support Full EN50155 compliance

More information

LLM-336S.Eth. Introduction. Features. Industrial Leased line modem with internal Ethernet Bridge.

LLM-336S.Eth. Introduction. Features. Industrial Leased line modem with internal Ethernet Bridge. LLM-336.Eth Industrial Leased line modem with internal Ethernet Bridge. LLM-336D.Eth LLM-336S.Eth Introduction The MuLogic LLM-336.Eth is a voiceband modem combined with an Ethernet bridge for connecting

More information

XPSMCMDO Digital output pairs expansion modules with screw term

XPSMCMDO Digital output pairs expansion modules with screw term Characteristics 2 Digital output pairs expansion modules with screw term Main Range of product Product or component type Device short name Electrical connection [Us] rated supply voltage Number of inputs

More information

Pilz Network Rail Innovation & Collaboration

Pilz Network Rail Innovation & Collaboration Pilz Network Rail Innovation & Collaboration COTS PLC technology in rail signalling LX PLC project David Collier, Pilz UK Business Development Tahir Ayub, Senior Design Authority Engineer, Network Rail

More information

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options: FEATURES E1 or Fractional E1 access unit Supports one data port with selectable sync data rates: n x 56, n x 64 kbps Optional sub-e1 drop & insert port for PABX connectivity Single slot supports MEGAPLEX

More information

DTM Distributed Transmitter Monitor

DTM Distributed Transmitter Monitor Distributed Transmitter Monitor 96 Communication Module The 96 functions as an RS232 to RS485 convertor and / or enables (32) modules to be networked together via Modbus. Combined with the -CFG configuration

More information

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor AS-i 3.0 Gateways 2 AS-i Masters, 1 PROFIBUS Slave Up to 32 release circuits up to 6 CAT4, SIL 3 safe output circuits on the Monitor safe relays or fast electronic safe outputs up to 32 independent AS-i

More information

RuggedMC RMC40 RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. 4-Port Ethernet Media and Speed Converter

RuggedMC RMC40 RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. 4-Port Ethernet Media and Speed Converter Features and Benefits 4-Ethernet Ports with Optional Dual Fiber Optics Three configurations to choose from: z2 10/100TX ports + 1 100FX port (SC/ST) z2 10/100TX ports + 2 100FX port (MTRJ/LC) z4 10/100TX

More information

BMEP processor module M580 - Level 1 - Distributed

BMEP processor module M580 - Level 1 - Distributed Characteristics processor module M580 - Level 1 - Distributed Main Range of product Product or component type Supply Complementary Number of racks 4 Local I/O processor capacity (discrete) Local I/O processor

More information

Ethernet I/O Card. Ethernet I/O Card. Introduction. DeltaV Product Data Sheet. Easy to use. Powerful integration solution. Modular, flexible packaging

Ethernet I/O Card. Ethernet I/O Card. Introduction. DeltaV Product Data Sheet. Easy to use. Powerful integration solution. Modular, flexible packaging August 2010 Page 1 The Ethernet IO Card provides a high speed Ethernet IO device integration platform Easy to use Powerful integration solution Modular, flexible packaging Introduction The DeltaV S-Series

More information

mark150s mark150/485s DDC controllers Summary

mark150s mark150/485s DDC controllers Summary mark150s mark150/485s DDC controllers Summary DDC (Direct digital control) controller mark150s and mark150/485s are free programmable process stations with ARM Cortex M4 processor and OS FreeRTOS. They

More information

Compact Multiprotocol I/O Module for Ethernet 16 Digital PNP Inputs TBEN-L5-16DIP

Compact Multiprotocol I/O Module for Ethernet 16 Digital PNP Inputs TBEN-L5-16DIP EtherNet/IP, Modbus TCP, or PROFINET slave Integrated Ethernet switch Supports 10 Mbps/100 Mbps 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass fiber reinforced housing Shock and vibration

More information

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station s 3 836 3836P01 Desigo TRA PL-Link IO Block Use with PXC3 series room automation station RXM39.1 The PL-Link IO Block contains the inputs and outputs controlled by a room automation station via PL-Link.

More information

LXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W

LXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W Characteristics motion servo drive - Lexium 28 - single and three phase 200...230 V - 750 W Main Range of product Lexium 28 Product or component type Device short name Format of the drive Line current

More information

CHIRON-4E1. E1 over Ethernet Multiplexer (TDM over IP)

CHIRON-4E1. E1 over Ethernet Multiplexer (TDM over IP) E1 over Ethernet Multiplexer (TDM over IP) Tranmission of up to 4x E1 PDH, G.703/704/723 E1 2048Mbit/s channels over Ethernet/IP network Built-in 5 port Gigabit Ethernet switch (4x 10/100/1000 Mbit/s RJ45

More information

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact Characteristics variable speed drive ATV320-0.75kW - 200...240V - 1 phase - compact Main Range of product Product or component type Product specific application Device short name Format of the drive Product

More information

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs E L E K T R O N I K Appliance Description Programmable safety center FPSC Fiessler Programmable Safety Center Flexible Hard- and Software concept Available with a safe bus system or/and two counter inputs

More information

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs 8 digital outputs 2 A FGEN-IOM

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs 8 digital outputs 2 A FGEN-IOM Multiprotocol I/O Module for the Ethernet protocols Modbus TCP, Ether- Net/IP and PROFINET PROFINET supports Fast Start-Up (FSU) EtherNet/IP supports QuickConnect (QC) Integrated Ethernet Switch FDT/DTM

More information

A0750 AC-DC POWER MODULE

A0750 AC-DC POWER MODULE FEATURES High power density, 7.7W / in³ Net Weight:< 2.2 KG Low profile : 40.8mm (fit 1U 19 shelf R2250 series) Efficiency: 77% ~ 86 % typical Power factor correction (meet IEC1000-3-2 requirements) Overvoltage

More information

General Specifications. P2-SCM Serial Communications

General Specifications. P2-SCM Serial Communications General Specifications Module Type Intelligent Modules per Base I/O Points Used Field Wiring Connector Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic

More information

Industrial IP67 Rated 8-Port 10/100Mbps M12 Fast Ethernet PoE Switch with Wide Operating Temperature

Industrial IP67 Rated 8-Port 10/100Mbps M12 Fast Ethernet PoE Switch with Wide Operating Temperature Industrial IP67 Rated 8-Port 10/100Mbps M12 Fast Ethernet Switch with Wide Operating Temperature In last few years, PLAET has launched various IP30 protected Industrial products which can deployed and

More information