1 EMC TESTS, SEMINARS, HARD AND SOFTWARE Technical Specification No. E-MIG1206-3P.doc Revised: 10.March MIG Tester Type MIG1206-3P 1 MIG Tester Type MIG1206-3P Introduction 1 2 General Brief description of the generator EUT connection (equipment under test) Standards, applications 2 3 Generator circuit, wave shapes definition Wave shape definition Mechanical dimensions, climatic conditions Technical data MIG1206-3P Combination Wave Generator Accessories Introduction The MIG "Modular-Impulse-Generator" is a flexible kit system, ready to quote tailored generators for special test applications. The MIG is a further innovative solution of EMC PARTNER AG to cover customers requests. The basic units are discharge modules (patent pending) which can be configured in serial or parallel, to offer an optimum solution for the customer need. The use of one type of discharge module guarantees a high reliability and a high quality. The MIG generators are compact and have an excellent value for money. The MIG generators are modern test equipment with the following features: Solid state impulse switch and solid state polarity change (no mechanical switch, no spark gaps or tubes) - advantages: low jitters, no high frequency switching noise, Microprocessor menu controlled, printer port and RS232 remote control Safety in accordance with VDE 0104 (safety circuit, connector for warning lamp) Integrated peak measurement for voltage and current. Peak display and monitor output for v,i Windows software for PC control available for windows 95, 98, 2000, NT or XP EMC PARTNER AG 1/8

2 2 General 2.1 Brief description of the generator The MIG1206-3P is a hybrid generator with a voltage wave shape 1,2/50 μs at "no load" and a current wave form 8/20 μs at short circuit. One representative application is testing of in circuit installed protection elements e.g. IEC The generator complies with IEC basic standard. The peak output voltage and current of the MIG are indicated on the display. The two BNC monitor outputs allow monitoring the voltage and current wave shapes by an oscilloscope 2.2 EUT connection (equipment under test) For EMC tests on power line in accordance with IEC or ITU K20 the delivered MC plugged cables must be used. For component test EMCP recommend the test cabinet TC-MIG24 heavy load placed on a customers table. The test cabinet is so designed that the cover can not be opened during the test. Only when the power line is switched "OFF", the output to the EUT is shorted, and the high voltage circuit is discharged, the test cabinet can be opened. The green and red warning lamps are integrated in the test cabinet. 2.3 Standards, applications IEC , EN , 1995 Electromagnetic compatibility (EMC) - Part 4 Testing and measuring techniques - Section 5: Surge immunity test. ANSI / IEEE 62.41: 1992 Recommended Practice on Surge Voltages in Low-Voltage AC Power Circuits. IEC "SURGE protective devices connected to low voltage power distribution system" Part 1: Performance requirements and testing methods. Class III tests IEC : 1989, High voltage test techniques. Part 1 General definition and test requirements. K.44 Resistibility tests for telecommunication equipment exposed to overvoltages and overcurrents (Figure A.3-5/K.44, CWG 1.2/50 and 8/20 μs ) K.20 Resistibility of telecommunication switching equipment to overvoltages and overcurrents (Table 5/K.20, CWG 1.2/50 and 8/20 μs) K.21 Resistibility of subscriber s terminal to overvoltages and overcurrents (Table 5/K.21. Test related to lighting surges CWG 1.2/50 and 8/20 μs) EMC PARTNER AG 2/8

3 3 Generator circuit, wave shapes definition The simplified circuit diagram of the MIG1206-3P generator is showed on the figure above. The values for the different components are in the way selected that the generator delivers a 1,2/50 μs voltage surge on open circuit and 8/20 μs current surge into a short circuit. The waveform of the voltage and the current is a function of the EUT input impedance. This impedance may change during surges to equipment and due either to proper operation of the installed protection devises, or to flashover or component breakdown. Therefore the 1,2/50 μs voltage and the 8/20μs current waves have to be available from the same test generator output as instantaneously required by the load. 3.1 Wave shape definition Definition of the waveforms: Wave shape "No load" (voltage Voc) Wave shape "Short circuit" (Current Isc) Um 90% 90% Im 50% Um 50% Im 30% 10% 1,2μ 8μs 50μs 20μs < 30% Im EMC PARTNER AG 3/8

4 3.2 Mechanical dimensions, climatic conditions MIG type Dimensions [mm] Weight [kg] Versions width x depth x height MIG1206-3P 600 x 660 x " 18 UH Power : Power voltage Power consumption L-N single phase 230 V/ 115V ±10% plus protective earth Maximum <400 VA Standby < 10 VA auto switching (230 V, 50 Hz) (115 V, 60 Hz) Environment conditions Temperature range C 0 to 35 C Humidity rh % 25 to 80% Pressure kpa 86 to 106 Accessories to MIG1206-3P see paragraph 3.4 Example MIG1206-3P - Generator EMC PARTNER AG 4/8

5 3.3 Technical data MIG1206-3P Combination Wave Generator Waveform at no load: No load = R > 100 Ω Rise time 1.2 μs ± 30% Time to half value 50 μs ± 20% Adjustable voltage range 1000 up to 12'500 V ± 10% Settings 1 V steps Maximum voltage 12'000 V ± 10% Polarity pos. / neg. / alternate High voltage output "low" maximum voltage between low and earth 260 V ac Waveform at short circuit: Short circuit R < 0,1 Ω Rise time 8 μs ± 20% Time to half value 20 μs ± 20% Under swing < 30% Maximum current 6'000 A ± 10% MIG1206-3P Circuit Parameter Impulse capacitance 10 μf ± 10% Energy at max. charging voltage 750 Joule Coupling capacitance between CWG and HS - output 2 Ω Source impedance Umax. / Imax. ± 10% MIG1206-3P Control, Measurement Minimum time between successive 30 seconds at 12'000 V shots at maximum charging voltage 5 seconds at 1000 V Impulse counter 1 up to 29'999 Trigger auto or manual synchronisation onto the power line voltage Ramps Voltage measurement: Peak value on Display Voltage waveform BNC output (u) Current measurement: Peak value on Display Current waveform BNC output (i) Protocol Limits on peak current and peak voltage for "passed - failed". The measuring range equal of current and voltage peak values - Voltage; - Polarity, - Synchronisation Accuracy 500 up to 13'200 V 10 V equals 12'000 V Accuracy 250 up to 6'600 A 10 V equals 6'000 A Peak value, Polarity, Number of shots, Angle of Synchronisation stop test protocol next test 1s steps ± 5% ± 5% General information to MIG control Set-up memory Up to 15 memory places Test sequences the test set-ups can be linked serially Ramps automatic linear variation of one parameter e.g. voltage, frequency etc EMC PARTNER AG 5/8

6 Synchronisation on different power line frequencies Pulse trigger 16, 2 / 3 ;40; 50; 60 Manual or automatic Front panel: with Trigger button Rear panel: with BNC plug Failure detection on EUT -External Input EUT failed -Selectable limit value for impulse voltage and current for SURGE Safety switching Emergency stop Switch off the EMC Test and the EUT power Test report Printer, connected to the standard port RS 232 Coupling: Connection between the MIG and the power supply line to the EUT. SURGE Automatic selection of the coupling path through MIG1206 IEC L1-PE, L2-PE, L3-PE, N-PE 10Ω 9μF plus 2 Ω generator impedance L1-L2, L2-L3, L1-L3, L1-N, L2-N, L3-N 2 Ω generator plus 18μF L1 + L2 or L1 + L3 et. to any other line 10 Ω plus 2 Ω generator impedance plus 2 x 9 μf coupling paths at high output Maximum Voltage 12'000 V Wave form 1,2/50μs Damping corresponds to IEC see test report De-Coupling: SURGE corresponds to IEC see test report Power supply EUT/ ac Nominal voltage Phase - Phase 440 V maximal Phase - Null 260 V maximal Phase - Earth 260 V maximal Synchronisation 1) Note Phase L1 Nominal current per Phase 32 A Over current protection switch 125 up to 250 A switching at <1s Power supply EUT/ dc Nominal voltage Phase - Phase or Phase - Neutral Nominal current 110 V 25 A Note 1) Coupling: Phases to PE or N SURGE L1: 0 equal 0 SURGE L2: 0 equal 120 SURGE L3: 0 equal 240 Coupling: Phases to Phases SURGE L1 to L2: 0 equal 330 SURGE L2 to L3: 0 equal 90 SURGE L1 to L3: 0 equal EMC PARTNER AG 6/8

7 3.4 Accessories TC-MIG24 Test cabinet Type Pictures accessories to High voltage outputs on top of MIG1206-3P Component and circuit tests up to 12 kv within the test cabinet EMC PARTNER AG 7/8

8 EMC PARTNER AG 8/8

Surge Current Generators PG **-****

Surge Current Generators PG **-**** Surge Current Generators PG **-**** Waveform 8/20 µs Surge current: 40 ka - 100 ka The surge current generators PG **-*** generate standard impulse currents with waveform 8/20 µs according to IEC, EN,

More information

Capacitor Test System

Capacitor Test System Component Tests Capacitor Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 2 Test System Overview.................. 3 Generator Specifications.................

More information

Advanced Test Equipment Rentals ATEC (2832) PSURGE Haefely is a subsidiary of Hubbell Incorporated.

Advanced Test Equipment Rentals ATEC (2832) PSURGE Haefely is a subsidiary of Hubbell Incorporated. Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) PSURGE 8000 Modular expandable surge system www.haefelyemc.com a brand of Haefely is a subsidiary of Hubbell Incorporated.

More information

KeyTek ECAT. Expert Computer-Aided Testing for pulsed EMI immunity. Technical Specifications

KeyTek ECAT. Expert Computer-Aided Testing for pulsed EMI immunity. Technical Specifications KeyTek ECAT Expert Computer-Aided Testing for pulsed EMI immunity The KeyTek ECAT is a modular, full capability EMC test system for measuring and analyzing the vulnerability of telecom, electronic, and

More information

Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment

Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment TR No. 176002 1.1.EDITION April 1st, 2015 Nippon Telegraph and Telephone Corporation Introduction This document describes

More information

TESTING T3-61. IMPULSE GENERATOR 1,2/50 µs, 12 kv IEC TEST EQUIPMENT

TESTING T3-61. IMPULSE GENERATOR 1,2/50 µs, 12 kv IEC TEST EQUIPMENT Testing d.o.o., Tržaška cesta 2 SI-1000 LJUBLJANA, SLOVENIA / EUROPE Tel.: +386 1 426 2199, Fax: +386 1 421 0366 E-mail: mail@testing.si http://www.iectestequipment.eu TESTING T3-61 IMPULSE GENERATOR 1,2/50

More information

Single Source, Total EMC Test Solutions

Single Source, Total EMC Test Solutions Single Source, Total EMC Test Solutions Experience the many benefits of working with recognized experts in the field of EMC (Electromagnetic Compatibility) testing. Our commitment to the discipline is

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12

More information

Thermo Scientific ECAT

Thermo Scientific ECAT Expert Computer-Aided Testing for pulsed EMI immunity Features & Benefits Tests for pulsed EMI hazards: EFT, Surge, PQF Ideal test system to address most applicable EMC & Telecom standards, including CE

More information

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers The low weight, small size, one-touch solution Portable appliance testing The Fluke 6000 series PAT testers Fluke 6200 and 6500 Test more appliances per day The Fluke 6200 and 6500 PAT testers verify the

More information

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module

More information

EMC PARTNER. ESD MODULAR HANDHELD TESTER Electrostatic Discharge Testing

EMC PARTNER. ESD MODULAR HANDHELD TESTER Electrostatic Discharge Testing EMC PARTNER ESD3000 - MDULAR HANDHELD TESTER Electrostatic Discharge Testing This document has been optimized for electronic media Accredited Calibration Quality at EMC PARTNER is based on an IS 9001 management

More information

EMISSION MEASUREMENT Power Frequency Testing

EMISSION MEASUREMENT Power Frequency Testing EMISSION MEASUREMENT Power Frequency Testing This document has been optimized for electronic media POWER FREQUENCY TESTING QUALITY AND RELIABILITY OF THE POWER NETWORK The power network is an essential

More information

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS

More information

EMC PARTNER. ESD MODULAR HANDHELD TESTER Electrostatic Discharge Testing

EMC PARTNER. ESD MODULAR HANDHELD TESTER Electrostatic Discharge Testing EMC PARTNER ESD3000 - MDULAR HANDHELD TESTER Electrostatic Discharge Testing Accredited Calibration Quality at EMC PARTNER is based on an IS 9001 management system. This is the foundation for an IS 17025

More information

MIL3000 Test System. Lightning Tests

MIL3000 Test System. Lightning Tests Lightning Tests MIL3000 Test System System Overview.................... 2 Applicable Standards................... 3 Features & Benefits................... 4 Application Options................... 6 Accessories......................

More information

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice Issued: July 1998 Status: Revised Version: C/08.10.2003 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs SIPROTEC easy 7SJ4 Numerical Overcurrent Protection Relay Powered by CTs Function overview Fig. /1 Description The SIPROTEC easy 7SJ4 is a numerical overcurrent protection relay which is primarily intended

More information

FL MC 2000E (SM40) LC

FL MC 2000E (SM40) LC IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features

More information

RT4B-110V/12A RECTIFIER

RT4B-110V/12A RECTIFIER The RT4B-110V/12A is a switched mode rectifier (SMR) module designed to provide up to 12A of output current into a 110V nominal system. It can be used with or without a cooling fan. With a fan it runs

More information

RT4F-110V/25A RECTIFIER

RT4F-110V/25A RECTIFIER The RT4F-110V/25A is a hot-pluggable switched mode rectifier (SMR) module designed to provide up to 25A of output current into a 110V nominal system. Examples of such systems are 60 cells lead acid (136V

More information

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL 200 VA bis 3.120 VA 10 V bis 80 V 2 A bis 320 A NL AC, NL Series Interface overview RS-232 X USB X GPIB O LAN O System bus O Analog X Analog isolated O X Standard O Option / not available NL1V20C40 2-quadrant

More information

Installation / Control Technique

Installation / Control Technique Installation / Control Technique Interface Relay, Interface Relay System Input-Output Interface Relay IK 3070, I_ 3070 0633 IK 3070 Circuit Diagrams IS 3070 According to IEC/EN 61 810-1 Relay, triac or

More information

LOW WEIGHT, SMALL SIZE,

LOW WEIGHT, SMALL SIZE, THE LOW WEIGHT, SMALL SIZE, ONE-TOUCH SOLUTION Portable appliance testing The Fluke 6000-2 PAT Testers Fluke 6200-2 and 6500-2 TEST MORE APPLIANCES PER DAY The Fluke 6200-2 and 6500-2 PAT testers verify

More information

SLI 15 INVERTER SERIES, 1500 W

SLI 15 INVERTER SERIES, 1500 W SLI 15 INVERTER SERIES, 1500 W FEATURES DESCRIPTION New, compact design: 1U height x 19" width x 14.94" depth; 19" rack-mountable High efficiency: up to 93% True sine wave output Parallelable output with

More information

VersaPoint I/O Module

VersaPoint I/O Module Output 24VDC Positive Logic 0.5A 14 Points Module is used to output 24VDC digital signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature 48.8mm

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) compact immunity test system www.axos.haefely.com a brand of Haefely is a subsidiary of Hubbell Incorporated. 2 AXOS

More information

LL1x50-E-DA. 1x50 W Dimmable DALI LED driver. 50 W V 0 / 50 Hz 60 Hz. Functional description. Mains characteristics

LL1x50-E-DA. 1x50 W Dimmable DALI LED driver. 50 W V 0 / 50 Hz 60 Hz. Functional description. Mains characteristics 1x50 W Dimmable DALI LED driver Hybrid dimming technique for high quality light 50 W 220 240 V 0 / 50 Hz 60 Hz Suitable for use in emergency lighting applications DALI control input, 1 % - 100 % dimming

More information

Military Test System. Lightning Tests

Military Test System. Lightning Tests Lightning Tests Military Test System System Overview.................... 2 Features & Benefits................... 4 Applications...................... 6 Applicable Standards................... 7 Technical

More information

02/11/2015

02/11/2015 35 mm - 1 Relay 8A OUR1 Part number 88867105 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external

More information

Feeder protection relay SPAA 121 C. Product Guide

Feeder protection relay SPAA 121 C. Product Guide Issued: April 1999 Status: Updated Version: C/06.03.2006 Data subject to change without notice Features Two-phase low-set phase overcurrent unit with definite time or inverse time characteristic Two-phase

More information

RT4F-48V/50A-WAC RECTIFIER

RT4F-48V/50A-WAC RECTIFIER The RT4F-48V/50A-WAC is a switched mode rectifier (SMR) module designed to provide up to 58A of output current into a 48V nominal system, over a wide range of AC input voltage. This rectifier has been

More information

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH) COMPACT LED DRIVERS PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH) 186762, 186763 Typical Applications Built-in in compact luminaires Shop lighting Downlights PrimeLine DALI dimmable & Selectable

More information

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O DATASHEET NI REM-11178 Digital Output Module for Remote I/O Short circuit and overload protection Drives up to 500 ma per channel (up to 8A per module) Spring-terminal connectors allow fast wiring without

More information

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21 Characteristics variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21 Main Range of product Product or component type Device application Device short name Variant Product destination Mounting

More information

Programmable Power Supply with DALI

Programmable Power Supply with DALI Programmable Power Supply with DALI Product picture Model Name ㅡ Features : ㅡ Suitable for LED lighting application ㅡ Programmable Power Supply Unit(Adjustable Output Current) ㅡ UL8750/UL1012(Non Class

More information

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide Combined Overcurrent and Earth-fault Product Guide Issued: April 1999 Status: Updated Version: C/18.04.2006 Data subject to change without notice Features Three-phase, low-set phase overcurrent unit with

More information

ISOMETER isopv with coupling device AGH-PV

ISOMETER isopv with coupling device AGH-PV Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) for photovoltaic plants up to AC 793 V/DC 1100 V Vorläufiges Datenblatt IsoPV_D00024_02_D_XXEN/07.2018 ISOMETER with coupling

More information

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers The low weight, small size, one-touch solution Portable appliance testing The Fluke 6000 series PAT testers Fluke 6200 and 6500 Test more appliances per day The Fluke 6200 and 6500 PAT testers verify the

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

Surge Protection Devices Ex9UE2

Surge Protection Devices Ex9UE2 Surge Protection Devices Ex9UE2 Surge Protection Devices Type 2 (Class II, T2, C) Tested according to EN 61643-11 Maximum continuous operational voltage U c from 275 V up to 440 V AC Versions with 1+0,

More information

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1 Manual PCD3.C90 Revision History Date Modification Asked by: Version 14.09.09 E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1 22.09.09 Added E/A Bus Connector PCD3.K116 Müller.R 1.2 06.01.10

More information

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren Solid-state Power OFF-delay Timer II DIN 22.5-mm Solid-state Power OFF-delay Timer High immunity to invertor noise. Long power OFF-delay times; S-series: up to 12 seconds, L-series: up to 120 seconds.

More information

LINEAR LED DRIVERS. ComfortLine Industry Selectable Current (LEDset) ComfortLine INDUSTRY SELECTABLE CURRENT (LEDset) ,

LINEAR LED DRIVERS. ComfortLine Industry Selectable Current (LEDset) ComfortLine INDUSTRY SELECTABLE CURRENT (LEDset) , LINEAR LED DRIVERS ComfortLine INDUSTRY SELECTABLE CURRENT (LEDset) 186695, 186696 Typical Applications Built-in in linear luminaires for Industrial lighting ComfortLine with selectable current HIGH POWER

More information

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Characteristics variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Main Range of product Altivar 32 Product or component type Product destination Product specific application

More information

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide Issued: April 1999 Status: Update Version: C/12.04.2006 Data subject to change without notice Features Sensitive low-set neutral overcurrent stage with definite time characteristic High-set neutral overcurrent

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters Applications Telecom IT Industrial Safety in compliance with IEC60950:1999, 3 rd edition; EN60950:2000; UL60950, 3 rd edition; CSA Standard C22.2 No.60950-00, 3 rd edition Features New, compact design:

More information

REGENERATIVE LOAD ERI SERIES

REGENERATIVE LOAD ERI SERIES Electronic DC Loads REGENERATIVE LOAD ERI SERIES The electronic loads of the ERI series feed the absorbed energy back into the local supply network. This protects the environment and reduces electricity

More information

Earth-fault Relay SPAJ 110 C. Product Guide

Earth-fault Relay SPAJ 110 C. Product Guide Issued: April 1999 Status: Updated Version: C/12.04.2006 Data subject to change without notice Features Low-set neutral overcurrent stage with definite time or inverse time characteristic High-set neutral

More information

This data sheet is only valid in association with the IL SYS INST UM E user manual.

This data sheet is only valid in association with the IL SYS INST UM E user manual. Inline analog input terminal, 4 inputs for connecting voltage signals Data sheet 8081_en_01_C01 PHOENIX CONTACT 2015-04-14 1 Description The terminal is designed for use within an Inline station. It is

More information

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel VCL-TP, Teleprotection Equipment With Trip Counter Display Panel Data Sheet Copyright: Valiant Communications Limited. 2008-2014 1 Product Overview VCL-TP, Teleprotection Equipment is an extremely reliable

More information

Sentinel Dual High Power

Sentinel Dual High Power VFI TYPE SOHO DAtACeNteR e-medical ONline Sentinel Dual High Power INDUStRY transport emergency 1:1 3:1 3,3-10 kva 6 USB plug Hot swap battery energy share HigHligHtS Simplified installation operating

More information

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma Data sheet 105597_en_01 PHOENIX CONTACT 2014-10-24 1 Description The module is designed for use within an ST station. It is

More information

DPO A4. Description. Module with 4 digital outputs. Datasheet

DPO A4. Description. Module with 4 digital outputs. Datasheet DPO A4 Module with 4 digital outputs Datasheet Description Module with 4 digital outputs. Main characteristics: 4 digital outputs Maximum output current: 2 A for each output, 7 A total Overcurrent and

More information

SEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits

SEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits Advanced Monitoring and Control System Compact Enclosure Full-Size Enclosure Major Features and Benefits The SEL-734B combines volt/var based capacitor bank control with power quality monitoring and advanced

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Block diagram Unit features Positive-guided relay outputs: 6 safety contacts (N/O), instantaneous 4 auxiliary

More information

Protection Device Test System

Protection Device Test System Component Tests Protection Device Test System Brief Overview of Phenomena................ 2 Applicable Standards................... 3 Test System Overview................... 4 Generator Specifications.................

More information

Published by and copyright 2015 Siemens AG Energy Management Freyeslebenstr Erlangen, Germany

Published by and copyright 2015 Siemens AG Energy Management Freyeslebenstr Erlangen, Germany Published by and copyright 2015 Siemens AG Energy Management Freyeslebenstr. 1 91058 Erlangen, Germany For more information, please contact our Customer Support Center Phone: +49 180/524 84 37 Fax: +49

More information

2 Principle of lightning protection

2 Principle of lightning protection 2 Principle of lightning protection The system for protecting a building against the effects of lightning must include: bprotection of structures against direct lightning strokes; bprotection of electrical

More information

4 channel PD tester for semiconductor test TPP

4 channel PD tester for semiconductor test TPP 4 channel PD tester for semiconductor test TPP New! Up to 18.3kV peak (13kV rms) Multi channel Partial discharge test system for check up the safety electric isolation of electronic components (e.g. opto

More information

ESS-2000 with Discharge gun TC-815P

ESS-2000 with Discharge gun TC-815P Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) ELECTROSTATIC DISCHARGE SIMULATOR ESS-2000 with Discharge gun TC-815P CONFORMING TO IEC 61000-4-2 R TC-815P ESS-2000

More information

Features. Description. Applications

Features. Description. Applications Description Features The electronic loads of the ZSAC series are optimized for the practical use in laboratories, manufacturing and quality control. Power: Voltage: Current: 400W... 12600W 260V... 440V

More information

Attachment plug with surge protection for coaxial signal interfaces. Connection: N connector, male/female

Attachment plug with surge protection for coaxial signal interfaces. Connection: N connector, male/female Extract from the online catalog CN-UB-70DC-6-SB Order No.: 2803153 Attachment plug with surge protection for coaxial signal interfaces. Connection: N connector, male/female Commercial data EAN 4046356293204

More information

PHOENIX CONTACT Features

PHOENIX CONTACT Features Electronic monitoring relay for temperature monitoring Data sheet 107385_en_00 1 Description PHOENIX CONTACT - 2016-05-10 Features Safety and system availability requirements are constantly on the increase

More information

APC Matrix-UPS 3kVA 208V/240V In 120/208/240V Out

APC Matrix-UPS 3kVA 208V/240V In 120/208/240V Out APC Matrix-UPS 3kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 2250 Watts / 3000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,

More information

Ethernet Protection A Whole Solution Han Zou, ProTek Devices

Ethernet Protection A Whole Solution Han Zou, ProTek Devices Ethernet Protection ------ A Whole Solution Han Zou, ProTek Devices Introduction: As Ethernet applications progress from 10BaseT to 10Gigabit and beyond, IC components are becoming more complicated with

More information

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide Combined Overcurrent and Earth-fault Product Guide Issued: April 1999 Status: Updated Version: C/19.04.2006 Data subject to change without notice Features Three-phase, low-set phase overcurrent unit with

More information

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault Issued: April 1999 Status: Updated Version: B/09.11.2001 Data subject to change without notice Features Sensitive restricted earth-fault protection stage for fast, selective earth-fault protection Sensitive

More information

LXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W

LXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W Characteristics motion servo drive - Lexium 28 - single and three phase 200...230 V - 750 W Main Range of product Lexium 28 Product or component type Device short name Format of the drive Line current

More information

Line Impedance Stabilization Network (LISN)

Line Impedance Stabilization Network (LISN) Model 3816/2 Line Impedance Stabilization Network (LISN) User Manual ETS-Lindgren Inc. reserves the right to make changes to any product described herein in order to improve function, design, or for any

More information

RT4F-120V/20A-WAC RECTIFIER

RT4F-120V/20A-WAC RECTIFIER The RT4F-120V/20A-WAC is a switched mode rectifier/charger module designed to provide up to 20A of output current into a 120V nominal system. This charger has been designed for use in conjunction with

More information

Technical Data TICRO 100

Technical Data TICRO 100 Technical Data TICRO 100 IEEE 1588/PTP Time Converter 2014 by OMICRON Lab V1.0 Visit www.omicron-lab.com for more information. Contact support@omicron-lab.com for technical support. Smart Measurement Solutions

More information

Circuit diagram. Time ranges. Function. Function diagrams. Notes. Dimension diagram. Page 1

Circuit diagram. Time ranges. Function. Function diagrams. Notes. Dimension diagram. Page 1 NGZ 11 ON-delay single-range timer relay Multi voltage for AC/DC 24 up to 240 V 1 function: ON-delay (AV) 13 time ranges available from 0.1 s to 100 h 1 change-over contact 2 LEDs for function display

More information

Protection Relays PHASE & RESIDUAL OVERCURRENT

Protection Relays PHASE & RESIDUAL OVERCURRENT Protection Relays PHASE & RESIDUAL OVERCURRENT Application The relay type NA016 can be used in radial networks as feeder or power transformer protection. In solidly grounded systems the residual overcurrent

More information

DATASHEET. Ultra Capacitor Charger, UCC-4

DATASHEET. Ultra Capacitor Charger, UCC-4 DATASHEET Ultra Capacitor Charger, UCC-4 Easy installation Monitoring and surveillance of operation Balancing to save energy 90-450 V DC 3.5A Output Modular Ultra Capacitor system Document no.: 4921260003

More information

F550e E-learning course Residual current devices basics RCDs Standards. ABB Group April 2, 2009 Slide 1

F550e E-learning course Residual current devices basics RCDs Standards. ABB Group April 2, 2009 Slide 1 F550e E-learning course Residual current devices basics RCDs Standards April 2, 2009 Slide 1 Objectives After completing this module, you will be able to have a clear overview of the residual current device

More information

M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS

M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS G1 Outdoor Surge Protector for AC/Traction network VP range Dimensions (in mm) 19 M8 44 73 diam. 47 6 mm² Electrical

More information

Power Supplies V7-T6-2 V7-T6-4 V7-T6-10 V7-T6-16 V7-T6-36 V7-T6-39 V7-T6-43

Power Supplies V7-T6-2 V7-T6-4 V7-T6-10 V7-T6-16 V7-T6-36 V7-T6-39 V7-T6-43 Power Supplies Power Supplies.1 General Purpose and Sensor Power Supplies Product Selection Guide................................... PSL Series.............................................. PSC Series..............................................

More information

Output Voltage* (nom.)(adjustable)

Output Voltage* (nom.)(adjustable) Industrial Power Supplies TBLC Series, 6 90 W Low profile case, module depth only 59,5mm Suitable for mounting in domestic installation panels Low output ripples and spikes Fully compliance to ECO-Standard

More information

LOW POWER PLA SERIES. Interfaces. Electronic DC Loads

LOW POWER PLA SERIES. Interfaces. Electronic DC Loads Electronic DC Loads LOW POWER PLA SERIES The electronic loads of PLA series combine the classic design of large, easy-to-read displays with modern interfaces and a wide range of functions. The devices

More information

National Standard of The People s Republic of China

National Standard of The People s Republic of China Translated English of Chinese Standard: GB/T17626.5-2008 Translated by: www.chinesestandard.net Wayne Zheng et al. Email: Sales@ChineseStandard.net ICS 33.100 L 06 GB National Standard of The People s

More information

LINEAR LED DRIVERS. ComfortLine NFC. ComfortLine NFC , , ,

LINEAR LED DRIVERS. ComfortLine NFC. ComfortLine NFC , , , LINEAR LED DRIVERS ComfortLine NFC 186697, 186698, 186699, 186700 Typical Applications Built-in in linear luminaires for Office lighting Industrial lighting ComfortLine NFC SELECTABLE OUTPUT CURRENT (NFC)

More information

REGENERATIVE LOAD ERI SERIES

REGENERATIVE LOAD ERI SERIES Electronic DC Loads REGENERATIVE LOAD ERI SERIES ERI Series Brief Profile The electronic loads of the ERI series feed the absorbed energy back into the local supply network. This protects the environment

More information

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS Characteristics SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS Main Range of product Product or component type Device short name Safety module application Function of module Jun 29, 2018

More information

PHOENIX CONTACT - 10/2009

PHOENIX CONTACT - 10/2009 Factory Line Switches With Standard Functions AUTOMATIONWORX Data Sheet PHOENIX CONTACT - 10/2009 Description The range of Factory Line switches with standard functions in numerous versions can be used

More information

Universal Power Supplies

Universal Power Supplies , Features Universal input: 90 264 VAC or 120 30 VDC Active power factor correction (>0.95) High efficiency up to 93% Load share function for up to 3 units in parallel Adjustable output voltage EMI/EMC

More information

CC COMPACT DIP SWITCH

CC COMPACT DIP SWITCH CC COMPACT DIP SWITCH COMFORTLINE DIP SWITCH C-R5 186841, 186842, 186843 Typical Applications Built-in in compact luminaires for Shop lighting Downlights Panels ComfortLine DIP switch C-R5 SELECTABLE OUTPUT

More information

Output Voltage* (nom.)(adjustable)

Output Voltage* (nom.)(adjustable) Industrial Power Supplies TBLC Series, 6 90 W Low profile case, module depth only 55 mm Suitable for mounting in domestic installation panels Very high efficiency and low standby power -> compliance to

More information

LineMaster 100. Continuous-line Recorder. ABB Instrumentation 10/ EN

LineMaster 100. Continuous-line Recorder. ABB Instrumentation 10/ EN LineMaster 100 Continuous-line Recorder 10/43-1.10 EN 1 to 4 measuring channels Format 144 mm x 144 mm; installed depth 250 mm Combined chart unit for roll chart (32 m) or folded chart paper (16 m) Measuring

More information

Datasheet 1-95 W/ mA CORtronic LED-Driver

Datasheet 1-95 W/ mA CORtronic LED-Driver Datasheet 1-95 W/ 50-700mA CORtronic LED-Driver Overview Brand Name CORtronic Description 1-95 W LED-Driver Input Voltage 230 ± 10 % Input Frequency 50 / 60 Hz Output Voltage 15 150 V Output Current 0.05

More information

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide

More information

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable 70 Series - Line monitoring relay 70 Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring

More information

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Residual overvoltage relay

Residual overvoltage relay Page 1 Issued: April 1999 Status: New Data subject to change without notice Features Definite-time residual overvoltage earthfault protection and supervision Two independent operation stages, e.g. one

More information

RE Product data sheet Characteristics. universal plug-in timing relay - flashing s..60 mn V AC - 2 OC. Main.

RE Product data sheet Characteristics. universal plug-in timing relay - flashing s..60 mn V AC - 2 OC. Main. Characteristics universal plug-in timing relay - flashing - 0.1 s..60 mn - 24..240 V AC - 2 OC Main Range of product Product or component type Discrete output type Contacts type and composition Width pitch

More information

PowerLogic power-monitoring units. DM6000 series digital panel meters. Technical data sheet

PowerLogic power-monitoring units. DM6000 series digital panel meters. Technical data sheet PowerLogic power-monitoring units digital panel meters Technical data sheet 2011 Authorized Distributor: WESCHLER INSTRUMENTS phone: 800-903-9870 440-378-6580 fax: 800-903-9590 440-238-0660 www.weschler.com

More information

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact Characteristics variable speed drive ATV320-0.37kW - 380...500V - 3 phase - compact Main Range of product Product or component type Product specific application Device short name Format of the drive Product

More information

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet PowerLogic power-monitoring units power meter Technical data sheet 2011 Basic energy meters Functions and characteristics PE86261 PE86260 PowerLogic PM1000 power meter. The PowerLogic power meters are

More information