1 <<Contents>> <<Index>> GS M06H-0E A Link H Modules A-bus Modules Contents LP0-0N A Link H Module... LP-0N iber-optic A Link H Module... 5 LR0-0N iber-optic A-bus Module... 7 LR0-0N iber-optic A-bus Type Module... 9 LR0-W A-bus Type Module... GS M06H-0E Yokogawa Electric Corporation th Edition Apr. 6, 08
2 Blank Page
3 <<Contents>> <<Index>> LP0-0N A Link H Module The LP0-0N A Link H Module provides a high-speed network that allows information exchange between the Range-free Multi-controllers. The LP0-0N is an A link H interface that provides a maximum of stations of data link (one is counted as one station). - It allows a maximum of eight s to be installed in a single main unit, to make up a multi-layer data link. The can be accessed only from a designated CPU. - The number of link points can be specified arbitrarily for each CPU. - Bus-type communication channels are employed to facilitate the expansion of s. - A Link H Modules can be connected easily using a two-twisted-pair (-wire) shielded cable. Specification Number of stations max. Link relays 08 per - SP05/08 and SP: 08 - SP/5/8/5/5/66 and SP7-S: 89 (non-continuous) - SP8/58/59/67 and SP76-7S: 6,8 (non-continuous) Link register 08 per - SP05/08 and SP: 08 - SP/5/8/5/5/66 and SP7-S: 89 (non-continuous) - SP8/58/59/67 and SP76-7S: 6,8 (non-continuous) Maximum. Number of links per station Same as above. Link relay and link register assignments Link relay: on 6-relay basis Link register: on per register basis Number of s SP05/08 and SP: max. SP, SP5, SP8, SP5, SP8, SP5, SP58/59, SP66/67, SP7-S and SP76-7S:8 max. Transmission speed 5 K, 50 K, 65 K or.5 Mbps (switch selectable) Transmission channel type -bus type Termination resistance 0 Ω at both ends (specified by a built-in switch when the line is terminated) Transmission distance km, 500 m, 50 m or 00 m (depends on transmission speed) Communication system Token-bus system Synchronization rame synchronization Transmission format Conforms to HDLC. Modulation and encoding system NRZI system Error detection CRC-CCITT, timeout RAS features Error detection through local loopback, hardware self-diagnostics, special relay and register functions Transmission media Two-twisted-pair (-wire) shielded cable (AWG0) Current consumption 70 ma External connection -point terminal block, M.5 screws External dimensions 8.9 (W) x 00 (H) x 8. (D) mm (Note) Weight 0 g Surrounding air Operating :0 to 55 C temperature range Storage :-0 C to 75 C Surrounding humidity Operating :0 to 90% RH (non-condensing) range Storage :0 to 90% RH (non-condensing) Surrounding atmosphere Must be free of corrosive gases, flammable gases or heavy dust. Note: The given dimensions exclude protrusions (See External Dimensions for details). Note: LP0-0N is not compatible with SP7-N and SP76-7N. Components and unctions ront View RDY SND ERR LP0-0N STATION NO. TERMINATOR O ON A B SG SHIELD Right Side View Indicators RDY: Lit when the internal circuit is functioning normally. SND: Lit when the is sending data normally. ERR: Lit when an error occurs. Station No. switch (STATION No.): Sets a station number (0 to ). The factory setting is 0. Terminator switch (TERMINATOR): ON : Terminator is enabled. O: Terminator disabled. The factory setting is O. A link H terminal block ( terminals, M.5 screws) Parameter switches Note: This figure is drawn with the panel cover removed. actory No. No. Parameter O ON Switch setting O ON Transmission See table O No. O.5 Mbps 50 Kbps speed to the right. O ON 65 Kbps 5 Kbps Operation Normal High O mode speed (Not used) O All Rights Reserved. Copyright 997, Yokogawa Electric Corporation GS M06H-0E Apr. 6, 08
4 Terminating resistor Terminating resistor <<Contents>> <<Index>> System Configuration Example. Connecting between Controllers The LP0-0N can be used to configure a system in which communication speed can be as high as.5 Mbps. LP0-0N A Link H A Link H s (.5 Mbps max., km max., stations). Connecting between Controllers, A500 and µa0 LP0-0N A Link H Module LP0-0N A Link H Module A500 A link 50 kbps (500 m max., stations) LP0-0N A Link Module for A500 µa0 - Set the transmission speed of the A Link H to 50 kbps. External Connection Diagram A link H A B SG SHIELD A link H A B SG SHIELD Maximum total cable length: S m A link H A B SG SHIELD. The maximum total cable length (S) varies depending on the transmission speed used.. The SHIELD terminal of this is internally connected to the G terminal of the power supply.. This has a built-in terminator. When configuring the at the end of the cable, set the terminator switch to ON. Cables Use two-pair (-wire) shielded cable (impedance 00 Ω ) when connecting A Link H s. Recommended cables: KM80- /KM8- (to be purchased separately). * or details on KM80- and KM8-, see YHLS Master Module, YHLS Slave Units and YHLS Communication Cables (for implementing high-speed remote I/O) (GS M06H6-0E). Operating Environment - The table below lists the CPU s that can be used with this. CPU Module SP, SP5 and SP5 SP05/ 08, SP, SP8, SP8, SP5/58/59, SP66/67, SP7-S, SP76-7S Style No. and ROM Rev. S Rev. 8 or later Note: or the revision number of a CPU, see the revision number label on the side panel. - The following table summarizes the requirements for the Ladder Diagram Support Program M, which can be used to set up the communications conditions of this. All versions of the Ladder Programming Tool Wideield, Wideield and Wideield can be used with this. Ladder Diagram Support Revision Program M S50-E Model and Suffix s Model Suffix Style Option LP0-0N External Dimensions Rev..08 or later stations max. 5 k, 50 k, 65 k or.5 Mbps km, 500 m, 50 m or 00 m Unit:mm 00 B05.VSD All Rights Reserved. Copyright 997, Yokogawa Electric Corporation GS M06H-0E Apr. 6, 08
5 <<Contents>> <<Index>> 5 LP-0N iber-optic A Link H Module The LP-0N iber-optic A Link H Module is a high-speed network that allows information exchange between the Range-free Multi-controllers. The LP-0N is a iber-optic A link H interface that provides a maximum of stations of data link (one is counted as one station). - It allows a maximum of eight s to be installed in a single main unit, to making up a multi-layer data link. The can only be accessed from a designated CPU. - The number of link points can be specified arbitrarily for each CPU. - It supports daisy-chain configuration using fiber-optic cables. - It does not guarantee normal data link in the entire network if any one station on the network is powered off. Number of stations Link relays Link registers Max. number of links per station Link relay and link register assignments Number of s Specification max. 08 per - SP05/08 and SP: 08 - SP/5/8/5/5, 66 and SP7-S: 89 (non-continuous) - SP8/58/59/67 and SP76-7S:6,8 (non-continuous) 08 per - SP05/08 and SP: 08 - SP/5/8/5/5/66 and SP7-S: 89 (non-continuous) - SP8/58/59/67 and SP76-7S: 6,8 (non-continuous) Same as above. Link relay: on 6-relay basis Link register: on per register basis SP05/08 and SP: max. SP, SP5, SP8, SP5, SP8, SP5, SP58/59, SP66/67, SP7-S, SP76-7S: 8 max. Transmission speed.5 Mbps Transmission channel Daisy chain type Transmission Maximum total distance: 0 km distance Maximum distance between stations: km Communication Token ring system Synchronization rame synchronization Transmission format Conforms to HDLC. Modulation and NRZI system encoding system Error detection CRC-CCITT RAS feature Self-diagnostics -core optical fiber (hard plastic clad quartz Transmission media fiber-optic H-PC) Current consumption 95 ma External dimensions 8.9 (W) x 00 (H) x 8. (D) mm Weight 0 g Surrounding air Operating :0 to 55 C temperature range Storage :-0 C to 75 C Surrounding humidity Operating :0 to 90% RH (non-condensing) range Storage :0 to 90% RH (non-condensing) Surrounding Must be free of corrosive gases, flammable atmosphere gases or heavy dust. Note: LP-0N is not compatible with SP7-N and SP76-7N. Components and unctions ront View RDY SND ERR LP-0N STATION NO ALINK Right Side View Indicators RDY: Lit when the internal circuit is functioning normally. SND: Lit when the is sending data normally. ERR: Lit when an error occurs. Station No. switch (STATION No.): Sets a station number (0 to ). The factory setting is 0. iber-optic connector Attach a dust cap in the port not used. O Parameter switches 0.VSD Note: This figure is drawn with the panel cover removed. No. Parameter O ON actory setting Intermediate Terminal Intermediate station station station O (Not used) O Operation mode Normal High speed O (Not used) O All Rights Reserved. Copyright 997, Yokogawa Electric Corporation GS M06H-0E Apr. 6, 08
6 <<Contents>> <<Index>> 6 Configuration Example External Dimensions Daisy-chain configuration Unit: mm LP-0N iber-optic A Link H iber-optic A Link H. The maximum distance between stations is km and the maximum total distance is 0 km.. The attached blank cover must be placed on any unused port of the terminating station. Operating Environment - There is no restriction on the type of CPU s that can be used with this. CPU Module Style No. and ROM Rev. SP, SP5 and SP5 SP05, SP 08, SP, SP8, SP8, SP5/58/59,SP66/67, SP7-S, SP76-7S S Rev. 8 or later Note: or the revision number of a CPU, see the revision number label on the side panel. - The following table summarizes the requirements for the Ladder Diagram Support Program M, which can be used to set up the communications conditions of this. All versions of the Ladder Programming Tool Wideield, Wideield and Wideield can be used with this. Ladder Diagram Support Revision Program M S50-E Model and Suffix s Model Suffix Style Option LP -0N Rev..08 or later stations max. Maximum total distance: 0 km Maximum distance between stations: km.5mbps Optional Accessories The customer should prepare fiber-optic cables satisfying the requirements listed below when connecting between iber-optic A Link H s. See iber-optic Cables (GSM06C9-0E) for details on fiber-optic cables. for iber-optic Cable Cores Yokogawa Cable Model Number KM60 KM60,KM6,KM6,KM65 iber-optic Cable Model No.(Size) DK-HP00/0 CCV-HC-0/07 iber-optic Cable type SI type SI type Vendor SWCC Showa Sumitomo Electric Cable System Core diameter 00±5μm Clad diameter m Transmission loss 7.0dB/km Max. 7dB/km Max. (λ=0.85μm,ta=5 ) (λ=0.8μm,ta=5 ) :Step-index optical fiber for iber-optic Cable Connectors Yokogawa Cable Model Number Optical connectors Model No. Vendor KM60 K-07 SWCC Showa Cable Systems lever lock bonding, polished KM65 C-0 C-07 Sumitomo Electric lever lock, crimping, cut KM60,KM6 KM6 C-00H C-07H Sumitomo Electric lever lock bonding, polished All Rights Reserved. Copyright 997, Yokogawa Electric Corporation GS M06H-0E Apr. 6, 08
7 <<Contents>> <<Index>> 7 LR0-0N iber-optic A-bus Module The LR0-0N is an interface for constructing a system that requires distributed placement of multiple s. The user can build up an efficient remote I/O system by installing LR0-0N s in the main- and sub-units and connecting them via a fiber-optic A-bus (fiber-optic cable). - With the 0-Mbps high-speed communications capability of the LR0-0N, the user does not have to worry about the I/O refresh time in ladder programming. - All I/O types and most special types* can be installed in sub-units and accessed just like s installed in the main unit. *:See "Restrictions on System Configuration" - No specific communications setup (environment setup) is required. - The optical transmission system makes the LR0-0N highly immune to noise. Transmission speed Transmission media Transmission distance Transmission configuration Maximum number of sub-units (systems) RAS features Specification 0 Mbps -core optical fiber (hard plastic clad quartz fiber-optic H-PC) Maximum total distance: 00 m Maximum distance between stations: 00 m Star 7 (systems) Shutdown I/O contact output on transmission channel error, reporting of transmission channel error location Current consumption 0 ma External dimensions 8.9 (W) x 00 (H) x 8. (D) mm Weight 00 g Surrounding air Operating :0 to 55 C temperature range Storage :-0 C to 75 C Surrounding humidity Operating :0 to 90% RH (non-condensing) range Storage :0 to 90% RH (non-condensing) Surrounding atmosphere Must be free of corrosive gases, flammable gases or heavy dust. Note: The maximum number of systems when µ-bus master station are used is system less than the value above for each µ-bus master station. Components and unctions ront View RDY ERR LR0-0N REMOTE SUB UNIT NO. Right Side View Indicators RDY: Lit when the internal circuit is functioning normally. ERR: Lit when the fails to detect an input signal from a port. Unit No. switch (SUB UNIT No.) Sets a unit number (0 to 7). 0 : Unit number of the main unit -7: Unit number of the sub-units 8,9: Cannot be used. iber-optic connector O Condition switches (-pole DIP switch) No. ON Shutdown output O Hold output O actory Setting ON *: Valid only for output s installed in a subunit. Note: This figure is drawn with the panel cover removed. All Rights Reserved. Copyright 997, Yokogawa Electric Corporation GS M06H-0E Apr. 6, 08
8 <<Contents>> <<Index>> 8 System Configuration Example Star Configuration Unit No. 0 Main unit Unit No. Unit No. Unit No. Operating Environment There is no restriction on the type of CPU s that can be used with this. Model and Suffix s Model Suffix Style Option LR0-0N Maximum total distance: 00 m Maximum distance between stations: 00 m Sub-units* LR0-0N iber-optic A-bus for External Dimensions Unit: mm Daisy-chain + Star Configuration Unit No. 0 Main unit A500 Unit No. Unit No. Unit No. Sub-units* A500 Unit No. 5 *: Maximum number of sub-units: 7 Unit No. LR0-0N iber-optic A-bus for LR0-0N iber-optic A-bus for A500 Restrictions on System Configuration Maximum total distance Number of connectable sub-units Number of fiber-optic A-bus s installable in a main unit Number of fiber-optic A-bus s installable in a sub-unit Modules installable in a sub-unit 00 m 7 max. 7 max. (no restrictions on the installation location) (no restrictions on the installation location) All I/O s, and special s except LP, LE0, LX0 and NX0 s. Optional Accessories Prepare fiber-optic cables satisfying the requirements listed below when connecting iber-optic A-bus s for extension. See iber-optic Cables (GS M06C9-0E) for details on fiber-optic cables. for iber-optic Cable Cores Yokogawa Cable Model Number KM60 KM60,KM6,KM6,KM65,KM69 iber-optic Cable Model No. (Size) DK-HP00/0 CCV-HC-0/07 iber-optic Cable type SI type SI type Vendor SWCC Showa Sumitomo Electric Cable System Core diameter 00±5μm Clad diameter m Transmission loss 7.0dB/km Max. 7dB/km Max. (λ=0.85μm,ta=5 ) (λ=0.8μm,ta=5 ) :Step-index optical fiber for iber-optic Cable Connectors Yokogawa Cable Model Number Optical connectors Model No. Vendor KM60 K-07 SWCC Showa Cable Systems lever lock bonding, polished KM65 C-0 C-07 Sumitomo Electric lever lock, crimping, cut KM60,KM6 KM6,KM67,KM69 C-00H C-07H Sumitomo Electric lever lock bonding, polished All Rights Reserved. Copyright 997, Yokogawa Electric Corporation GS M06H-0E Apr. 6, 08
9 <<Contents>> <<Index>> 9 LR0-0N iber-optic A-bus Type Module The LR0-0N is an interface for constructing a system that requires distributed placement of multiple s. The user can build up an efficient remote I/O system by installing LR0-0N s in the main- and sub-units and connecting them via a fiber-optic A-bus (fiber-optic cable). - With the 0-Mbps high-speed communication capability of the LR0-0N, the user does not have to worry about the I/O refresh time in ladder programming. - All I/O types and most special types* can be installed in sub-units and accessed just like s installed in the main unit. *:See "Restrictions on System Configuration" - No specific communication setup (environment setup) is required. - The optical transmission system makes the LR0-0N highly immune to noise. - A single sub-unit can be segmented into a maximum of 8 stations. - A -port (send/receive) system allows daisy-chain configuration. - The loop system is switched into two pairs of daisy-chain systems when a disconnection occurs in the system, thereby improving system reliability. Transmission speed Transmission media Transmission distance Transmission configuration Maximum number of sub-stations Maximum number of systems Maximum number of sub-stations per system Maximum total distance per system Maximum distance between stations RAS features Specification 0 Mbps -core optical fiber (hard plastic clad quartz fiber-optic H-PC) Maximum distance between stations: 500 m Maximum total distance:. km ( stations) Star, daisy chain, loop 56 7 (Note). km ( stations) 500 m Shutdown I/O contact output on transmission channel error, reporting of transmission channel error location Current consumption 60 ma External dimensions 8.9 (W) x 00 (H) x 8. (D) mm Weight 0 g Surrounding air Operating :0 to 55 C temperature range Storage :-0 C to 75 C Surrounding humidity Operating :0 to 90% RH (non-condensing) range Storage :0 to 90% RH (non-condensing) Surrounding atmosphere Must be free of corrosive gases, flammable gases or heavy dust. Note: The maximum number of systems when µ-bus master station are used is system less than the value above for each µ-bus master station. Components and unctions ront View RDY ERR ERR LR0-0N REMOTE SUB UNIT NO. LET SLOT NO. Indicators RDY: Lit when the internal circuit is functioning normally. ERR, : Lit when the fails to ERR detect an input signal from a port. Unit No. switch (SUB UNIT No.): Sets a unit number (0 to 7). 0 : Unit number of the main unit -7 : Unit number of sub-units 8, 9 : Cannot be used. irst slot number switch (LET SLOT NO.) Used to set the first slot number (hexadecimal) of the base. iber-optic connector Attach a dust cap, in not using the port. Condition Switches No. Meaning O ON actory set * Hold/reset output on Hold * Shutdown communication error output output ON Port used Port Both ports * O Channel configuration Daisy chain or star Loop O Reserved O *: Valid only for output s installed in a sub-unit. *: Continues operation if transmission channel has been secured and system operation is continued. *: Both port and port are used. Light Power Setup Switches No. Meaning Distance between stations (iber-optic cable length) (m) 5 Port O ON O ON intensity O O ON ON 7 Port O ON O ON intensity O O ON ON Right Side View O O Note: This figure is drawn with the panel cover removed. All Rights Reserved. Copyright 997, Yokogawa Electric Corporation GS M06H-0E Apr. 6, 08
10 <<Contents>> <<Index>> 0 System Configuration Example Daisy-chain configuration main unit LR0-0N iber-optic A-bus Type iber-optic A-bus Substation Configuration - Substation Configuration Example The user can configure two or more sub-stations by splitting a sub-unit using the fiber-optic A-bus type. A sub-unit logically consists of 6 slots. A maximum of 7 sub-units can be used with the main unit. Main unit Slot 6 stations max. Sub-unit Sub-unit Sub-unit 7 Loop configuration main unit LR0-0N iber-optic A-bus Type iber-optic A-bus - Split Patterns Sub-units can be split in several patterns. Select an appropriate pattern according to the configuration of your system. stations max. Split pattern BU06 BU06 BU09 Slot No. BU06 BU0 BU0 BU0 Number of sub-stations BU0 BU0 BU0 BU0 BU06 BU0 BU0 ree ree ree ree BU0 BU0 BU0 BU0 BU0 ree BU0 ree BU0 ree BU0 ree 8 Restrictions on System Configuration Number of iber-optic A-bus Type s installable in a master station Number of iber-optic A-bus Type s installable in a sub-station Modules installable in a sub-station 7 (In case of subunit split : 5) All I/O s, and special s except LP, LE0, LX0 and NX0 s. When pattern () is used, for example, it is possible to connect together up to 7 sub-units, providing a maximum of stations. A -station system (maximum configurable system) can be configured by combining 6 sets of pattern (5) and set of pattern (6). The number of I/O s that can be installed in pattern (6) is per sub-station. All Rights Reserved. Copyright 997, Yokogawa Electric Corporation GS M06H-0E Apr. 6, 08
11 <<Contents>> <<Index>> Number of s and Maximum Total Distance (m) Maximum Total Distance (m) Number of Daisy-chain Loop Subconfiguration configuration stations Number of Substations Maximum Total Distance (m) Daisy-chain Loop configuration Do not lay cables such that the actual fiber-optic cable length exceeds the Maximum total distance, or the distance between two stations exceeds the maximum distance allowed between stations (500 m). External Dimensions Unit: mm Operating Environment - The following table lists the type of CPU s that can be used with this. CPU Module Style No. and ROM Rev. * SP, SP5 and SP5 S Rev. 8 or later * SP05/08, SP, SP8, SP8, SP5/58/59, SP66/67, SP7/76 BP0, BP0 and P6 *: or the revision number of a CPU, see the revision number label on the side panel. *: Supports logging of transmission channel error location. - The following table summarizes the requirements for the Ladder Diagram Support Program M, which can be used to set up the communications conditions of this. All versions of the Ladder Programming Tool Wideield and Wideield can be used with this. Ladder Diagram Support Program M Revision S50-E Rev..08 or later *: Supports logging of transmission channel error location. - The following table lists the type of base s that can be used with this. Base Module ID Mark BU0 R 0 or later BU05 BU06 R 0 or later BU09 BU BU6 Model and Suffix s Model Suffix Style Option LR0-0N Maximum total distance:. km Maximum distance between stations: 500 m Optional Accessories Prepare fiber-optic cables satisfying the requirements listed below when connecting iber-optic A-bus Type s for extension. See iber-optic Cables (GS M06C9-0E) for details on fiber-optic cables. for iber-optic Cable Cores Yokogawa Cable Model Number iber-optic Cable Model No. (Size) iber-optic Cable type KM60 KM60,KM6, KM6,KM65,KM69 KM67 DK-HP00/0 CCV-HC-0/07 CCV-HG-0/08 SI type SI type GI type SWCC Showa Sumitomo Electric Vendor Cable System Core diameter 00±5μm Clad diameter m 7.0dB/km Max. 7dB/km Max. Transmission 8dB/km Max. (λ=0.85μm, (λ=0.8μm, loss (λ=0.8μm, Ta=5 ) Ta=5 ) Ta=5 ) :Step-index optical fiber :Graded-index optical fiber for iber-optic Cable Connectors Yokogawa Cable Model Number Optical connectors Model No. Vendor KM60 K-07 SWCC Showa Cable Systems lever lock bonding, polished KM65 C-0 C-07 Sumitomo Electric lever lock, crimping, cut KM60,KM6 KM6,KM67,KM69 C-00H C-07H Sumitomo Electric lever lock bonding, polished All Rights Reserved. Copyright 997, Yokogawa Electric Corporation GS M06H-0E Apr. 6, 08
12 0 5 <<Contents>> <<Index>> LR0-W A-bus Type Module The LR0-W is an interface for constructing a system that requires distributed placement of multiple s. The user can build up an efficient remote I/O system by installing LR0-W s in the main- and sub-units and connecting them via a A-bus. - With the 0-Mbps high-speed communication capability of the LR0-W, the user does not have to worry about the I/O refresh time in ladder programming. - All I/O types and most special types* can be installed in sub-units and accessed just like s installed in the main unit. *:See "Restrictions on System Configuration" - Both daisy-chain and loop configuration options are supported. - The loop system is switched into two pairs of daisy-chain systems when a disconnection occurs in the system. Specification Transmission speed 0 Mbps two-pair (-wire) shielded cable Transmission media (impedance 00Ω) Maximum total distance:70m Transmission distance Maximum distance between stations: 0 m Transmission configuration Star, daisy chain, loop Maximum number of 7 subunits (systems) (Note) Shutdown I/O contact output on transmission RAS features channel error, reporting of transmission channel error location Must be installed inside panel enclosure or Installation location system Current consumption 0 ma External dimensions 8.9 (W) x 00 (H) x 8. (D) mm Weight 05 g Surrounding air Operating : 0 to 55 C temperature range Storage : -0 C to 75 C Surrounding humidity Operating : 0 to 90% RH (non-condensing) range Surrounding atmosphere Storage : 0 to 90% RH (non-condensing) Must be free of corrosive gases, flammable gases or heavy dust. Note: The maximum number of systems when µ-bus master station s are used is system less than the value above for each µ-bus master station. The combined maximum number of systems is 7 when A bus- s are used with iber-optic A bus- s and iber-optic A bus s. Components and unctions ront View RDY ERR ERR LR0-W REMOTE 0 R- R+ T- T SHIELD SUB UNIT NO. R- R+ T- T+ Right Side View ront Indicators RDY ERR, ERR : Lit when the internal circuit is functioning normally. : Lit when the fails to detect an input signal from a port. Unit No. Indicator 0 : Unit number of the main unit -7 : Unit number of sub-units Communication port O Rear This figure is drawn with the panel cover removed. Parameter switches Condition Switches SW No. Meaning O ON actory setting * Hold/reset output on communication error Hold output * Shutdown output ON Port used Port Both ports * O Channel configuration Daisy chain or star Loop O Reserved O *: Valid only for output s installed in a sub-unit. *: Continues operation if transmission channel has been secured and system operation is continued. *: Both port and port are used. All Rights Reserved. Copyright 997, Yokogawa Electric Corporation GS M06H-0E Apr. 6, 08
13 <<Contents>> <<Index>> System Configuration Example Daisy-chain configuration Main unit LR0-W A-bus Type A-bus Type Operating Environment - The following table lists the type of CPU s that can be used with this. CPU Module Style No. and ROM Rev. * SP, SP5 and SP5 S Rev. 8 or later * SP05, SP08, SP, SP8, SP8, SP5, SP58/59, SP66/67, SP7/76 BP0, BP0 and P6 *: or the revision number of a CPU, see the revision number label on the side panel. *: Supports logging of transmission channel error location. 7 stations max. - The following table summarizes the requirements for the Ladder Diagram Support Program M that can be used with the. All versions of the Ladder Programming Tool Wideield, Wideield and Wideield can be used with this. Ladder Diagram Support Program M Revision S50-E Rev..08 or later * *: Supports logging of transmission channel error location. Loop configuration Main unit LR0-W A-bus Type A-bus Type 7 stations max. - All versions of the Ladder Programming Tool Wideield can be used with this. Model and Suffix s Model Suffix Style Option LR0 -W External Dimensions Maximum total distance: 70 m Maximum distance between stations: 0 m Unit: mm Restrictions on System Configuration Number of A-bus Type s 7 installable in a main unit Number of A-bus Type s installable in a subunit All I/O s, and special s except LP, Modules installable in a subunit LE0, LX0 and NX0 s, 00 Cables Use two-pair (-wire) shielded cable (impedance 00Ω) when connecting A-bus Type s. Recommended cable: KM80- (tested for noise immunity, to be purchased separately) * or details on KM80-, see GSM6H6-0E. All Rights Reserved. Copyright 997, Yokogawa Electric Corporation GS M06H-0E Apr. 6, 08
FA-M3 FA Link H Modules FA-bus Modules. Contents. F3LP02-0N FA Link H Module F3LP12-0N Fiber-Optic FA Link H Module... 5
GS M06H-0E FA Link H Modules FA-bus Modules Contents FLP0-0N FA Link H Module... FLP-0N Fiber-Optic FA Link H Module... 5 FLR0-0N Fiber-Optic FA-bus Module... 7 FLR0-0N Fiber-Optic
More informationUser s Manual FA Link H Module Fiber-optic FA Link H Module Model: F3LP02-0N, F3LP12-0N
User s Manual FA Link H Module Fiber-optic FA Link H Module Model: F3LP02-0N, F3LP12-0N IM 34M06H43-01E IM 34M06H43-01E 5th Edition Blank Page Applicable Product i Range-free Multi-controller FA-M3 - Model
More informationGeneral Specifications
General GS 34M06C01-01E FA-M3 Basic Modules (Base, Power Supply, CPU Modules and ROM Packs) F3BU04-0N, F3BU06-0N, F3BU05-0D, F3BU09-0N, F3BU13-0N, F3BU16-0N F3PU10-0S, F3PU0-0S, F3PU30-0S,
More informationAppendix G. CJ1W-CIF11 RS-422A Converter
CJ1W-CIF11 RS-422A Converter The CJ1W-CIF11 RS-422A Converter connects directly to a CS/CJ-series RS-232C port and converts RS- 232C to RS-422A/485. Specifications General Specifications Item Specification
More informationAnalog Input/Output Modules
User s Manual Analog Input/Output Modules Addendum Manual No. :IM 34M06H11-01E Manual Title :Analog Input/Output Modules Edition :1st Edition With the adoption of the CE Marking conformance declaration
More informationTOSLINE-S20 Active Star Coupler Instruction Manual
TOSLINE - S20 Active Star Coupler Instruction Manual September, 1995 Toshiba International Corporation UM-TLS20**-E004 Table of Contents 1. Introduction... 2 2. Overview... 3 3. Specifications... 4 3.1
More informationGeneral. Specifications. F3NC96-0N Positioning Module (with MECHATROLINK-II Interface) GS 34M6H60-02E. General. Specification
General Specifications GS 34M6H60-02E F3NC96-0N Positioning Module (with MECHATROLINK-II Interface) General This positioning module is to be installed on the base unit of a FA M3 range free controller
More informationNX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration
NX-series SSI Input Unit CSM DS_E_1_1 Read position information from encoders with Synchronous Serial Interface (SSI). Process SSI encoder input data using the MC Function Modules of the NJ-series Machine
More informationT1K MODBUS Base Controller Specifications
Base Controller 1 2 In This Chapter.... Base Controller Setting the DIP Switches Setting the Rotary Address Switches Port Pin out and Wiring RJ12 Serial Port Pin out and Wiring 2 2 Base Controller General
More informationR6-NC1 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL CC-Link INTERFACE MODULE MODEL. (CC-Link Ver.1.10; for 16-point analog signals)
INSTRUCTION MANUAL CC-Link INTERFACE MODULE (CC-Link Ver..; for -point analog signals) MODEL R-NC BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received
More informationPROFIBUS Repeater PRC P PROFIBUS Converter PCF PF P PROFIBUS Converter PCF PF P20.05
Contents chapter age General information............................... 00 Repeater.......................................... 10 Repeater RC 67-10............................... 10.01 Converter.........................................
More informationFL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B
Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide
More informationRemote I/O Product Specification
Table of Contents 1. Product Overview... 1 1.1 Product List:... 1 1.1.1 Coupler List:... 1 1.1.2 Digital I/O List:... 1 2. Fieldbus Coupler... 2 2.1 CANopen Specifications... 2 2.2 Ethernet TCP/IP Specifications...
More informationBEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL PNP TRANSISTOR OUTPUT MODULE, 16 points (MECHATROLINK-I / -II, short circuit protection)
INSTRUCTION MANUAL PNP TRANSISTOR OUTPUT MODULE, 16 points (MECHATROLINK-I / -II, short circuit protection) R7ML-DC16D MODEL R7ML-DC16D BEFORE USE... Thank you for choosing M-System. Before use, please
More informationYHLS Master Module. User s Manual. Applicable Modules: Model Code Model Name F3LH01-1N YHLS Master Module F3LH02-1N YHLS Master Module
User s Manual YHLS Master Module IM 34M06H46-04E Applicable Modules: Model Code Model Name F3LH01-1N YHLS Master Module F3LH02-1N YHLS Master Module Yokogawa Electric Corporation IM 34M06H46-04E 2nd Edition
More information1) Indicates that the identified danger WILL cause physical and property damage.
CC-Link Ver.1.10 FX2N-16CCL-M CC-Link SYSTEM MASTER BLOCK HARDWARE MANUAL JY992D93201D This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation
More information1 1 Getting Started $ "% # + %#! & %! + % $!% +!% $% # * %&# $ +!% ' *!# * %&# $ + $$ %!% "&% &%"&% # $$ $ +!( % " % $!%! %$ + $) % "$!# %% "!
2 Manual Introduction The Purpose of this Manual This manual shows you how to install, program, and maintain the equipment. It also helps you understand the system operation characteristics. Who Should
More informationRemote I/O Product Specification
Table of Contents 1. Product Overview... 1 1.1 Product List:... 1 1.1.1 Coupler List:... 1 1.1.2 Digital I/O List:... 1 2. Fieldbus Coupler... 2 2.1 CANopen Specifications... 2 2.2 Ethernet TCP/IP Specifications...
More informationInstallation and Setup
Installation and Setup 1 In This Chapter Installing the H PBC The Profibus Network Configuring the Controller Installing the H PBC Setting the Node Address Setting the Node Address Profibus DP is usually
More informationAppendix 3 Using NS-AL002 Converters
Appendix 3 Using Converters The RS-232C/RS-422A Converter is connected directly to RS-232C port A or B of the, and converts RS-232C communications to RS-422A/RS-485. Any of the Converters listed in Appendix
More informationInstallation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module
Installation and Setup 1 2 In This Chapter.... Installing the H0 PSCM The Profibus Network Configuring the Module 2 2 Installing the H0 PSCM Remove the Slot Cover The first step in installing the option
More informationFL MC 2000E (SM40) LC
IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features
More informationMODEL: R2K-1 SEN TRONIC AG. R2K Series
1 MODEL: R2K-1 R2K Series /RS-485 CONVERTER Functions & Features Bidirectional converter between and RS-485 used when connecting Modbus RS-485 devices to a PC CE marking Standard: Conforms to, EIA Transmission
More informationIO-AO6X I/O Expansion Module 6 Isolated Analog Outputs
IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated
More informationPRODUCT OVERVIEW. Redundant CPUs. High speed µs processing. Redundant power supplies. Large 62K-word program and 24Kword data memory capacity
PRODUCT OVERVIEW ` CVM1 Series The CVM1D Duplex system s redundancy is a new option in Omron s large controllers. Two redundant CPUs and power supplies ensure that processes will continue operation when
More informationHITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions
HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction
More informationH704-42(H)(E), H704-42/1(H)(E)
POWER MONITORING INSTALLATION GUIDE H704-42(H)(E), H704-42/1(H)(E) Branch Current Monitor DANGER NOTICE Installer's Specifications General: Operating Temp. Range 0 to 60 C (32 to 140 F) (
More informationMODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series
Remote I/O R3 Series FL-net INTERFACE MODULE (OPCN-2, Ver.2. supported) Functions & Features FL-net (OPCN-2), Ethernet based, controller level network, compatible remote I/O 1 Mbps/1 Mbps cyclic transmission
More informationMODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)
PC Recorders Series PC RECORDER (4 totalized counter inputs, 8 contact inputs and outputs) Functions & Features Industrial recorder on PC Totalized counter inputs Counts stored in E 2 PROM Easy system
More informationCommunication Controller CC-Link/CPL Converter CMC10A
No. CP SS 1766E Communication Controller CC-Link/CPL Converter CMC10A The communication controller CMC10A is a converter designed for the communication between Yamatake's digital indicating controller
More informationMODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)
MODEL: R-NE Remote I/O R Series ETHERNET INTERFACE MODULE (Modbus/TCP) 7. (.8) 9 (.9) (.) mm (inch) MODEL: R-NE-[][] ORDERING INFORMATION Code number: R-NE-[][] Specify a code from below for each [] and
More informationEX-RC1 Remote I/O Adapter
EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter
More informationDLS-E2 TELEMETERING UNIT BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (16 contact inputs & 16 open collector outputs)
INSTRUCTION MANUAL TELEMETERING UNIT ( contact inputs & open collector outputs) MODEL DLS-qE DLS-E BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received
More informationEtherCAT Remote I/O Terminal GX series
EtherCAT Remote I/O Terminal GX series Digital I/O Terminal 2-tier Terminal Block Type Digital I/O Terminal 3-tier Terminal Block Type Digital I/O Terminal e-con Connector Type Analog I/O Terminal 2-tier
More informationYHLS Master Module. User s Manual. Applicable Modules: Model Code Model Name F3LH02-0N YHLS Master Module. IM 34M6H46-01E 1st Edition IM 34M6H46-01E
User s Manual YHLS Master Module IM 34M6H46-01E Applicable Modules: Model Code Model Name F3LH02-0N YHLS Master Module Yokogawa Electric Corporation IM 34M6H46-01E 1st Edition Applicable Product: i Range-free
More informationPHOENIX CONTACT - 11/2008
The small form-factor pluggable module (SFP module) is a plug-in input/output module for fiber optics that is used in Gigabit Ethernet AUTOMATION Data Sheet 7762_en_01 PHOENIX CONTACT - 11/2008 1 Description
More informationRTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM
RTD-RA Installation Instructions 37.50 LEDS 4 3 2 1 D English Installation Instructions 80.00 80.00 ALL DIMENSIS IN MM C realtime Control Systems A B LEDS 4 3 2 1 D S21 J3 J6 1 2 3 4 J5 5 6 7 0V S1 0V
More informationATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21
Characteristics variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21 Main Range of product Product or component type Device application Device short name Variant Product destination Mounting
More informationEX-RC1 Remote I/O Adapter
EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter
More informationMED102A. Industrial Serial to Single-mode Fiber Converter
MED102A - 0708 pg. 1 / 5 MED102A Industrial Serial to Single-mode Fiber Converter Data Rates up to 115.2 kbps 9 Mile (15 km) Range 10 to 48 VDC Input Voltage Wide Operating Temperature 2000V Isolation
More informationIndustrial Media Converters
Wireless AP Industrial s Introduction & Features Fiber s Ethernet s Serial s s Distance Extension With Higher Immunity Introduction The media converters have incorporated SUNIX advanced technologies such
More informationR3-NE1 ETHERNET INTERFACE MODULE MODEL. Remote I/O R3 Series. (Modbus/TCP)
Remote I/O R Series ETHERNET INTERFACE MODULE (Modbus/TCP) MODEL R-NE MODEL & SUFFIX CODE SELECTION R NE MODEL POWER INPUT K : V AC L : V AC R : V DC N : No power supply * *. Choose N (no power supply)
More informationMODEL: GR8-EM. Communication Adaptor GR8 Series
Communication Adaptor GR8 Series Ethernet/RS-485 Adaptor (Modbus use) Functions & Features Bidirectional protocol converter for Modbus/TCP (Ethernet) and Modbus RTU (RS-485) Fast response time thanks to
More informationATV340D18N4E variable speed drive - 18kW- 400V - 3 phases - ATV340 Ethernet
Characteristics variable speed drive - 18kW- 400V - 3 phases - ATV340 Ethernet Main Range of product Product or component type Device application Device short name Variant Product destination Mounting
More informationPHOENIX CONTACT - 10/2009
Factory Line Switches With Standard Functions AUTOMATIONWORX Data Sheet PHOENIX CONTACT - 10/2009 Description The range of Factory Line switches with standard functions in numerous versions can be used
More informationFiber optic converter audio and CAN TA OPERATION MANUAL
Fiber optic converter audio and CAN TA-110.1 IOA110-1 March 2009 LANEX S.A., Technical support: tel. ul.ceramiczna 8, 20-150 Lublin tel. +48 81 443 96 36 Contents 1. General Characteristics.... 5 1.1.
More informationEX-RC1 Remote I/O Adapter
EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter
More informationD2 RMSM/ T1K RSSS Remote I/O System
D2 RMSM/ 2 2 D2 RMSM/ Remote Master (D2-RMSM) Features RUN--Turns N when the module is operating correctly. Remote Master DIAG--Turns N when there is a hardware failure. I/--Turns N when the setup program
More informationHygroFlex HF3 Transmitters and Thermohygrostats: User Guide
Page 1 of 26 HygroFlex HF3 Transmitters and thermo-hygrostats Page 2 of 26 Table of contents 1 Overview... 3 2 Mechanical configurations and dimensions... 4 2.1 Display option... 5 3 General description...
More informationExpansion Module HZS 541-1S
Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs
More informationTopic: The PLC link function of DVP series PLCs
Topic: The PLC link function of DVP series PLCs Applicable model Keyword DVP-EH3 series, DVP-SV2 series, DVP-ES2/EX2 series, DVP-SX2 series, DVP-SA2 series, DVP-SS2 series, DVP-SE series, DVP-10MC series,
More informationWindows 8 / 7 CONTENTS. USB to RS-485 Converter. Part Number: USB FEATURES. 2 SPECIFICATIONS. 2 CONNECTIONS.. 3
CONTENTS USB to RS-485 Converter Part Number: USB-485-1 INTRODUCTION 2 FEATURES. 2 SPECIFICATIONS. 2 PIN ASSIGNMENT 2 CONNECTIONS.. 3 DRIVER INSTALLATION QUICK GUIDE.. 3 DRIVER INSTALLATION EXAMPLES..
More informationR3-GE1 BEFORE USE... INSTALLATION POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP)
INSTRUCTION MANUAL ETHERNET INTERFACE MODULE (Modbus/TCP) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have
More informationRemote I/O Product Specification
Table of Contents 1. Product Overview... 1 1.1 Product List:... 1 1.1.1 Coupler List:... 1 1.1.2 1.1.3 Digital I/O List:... 1 Analog I/O List:... 1 2. Fieldbus Coupler... 2 2.1 CANopen Specifications...
More informationIntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN
IntesisBox HS-RC-MBS-1 v.0.1 Modbus RTU (EIA-485) Interface for Hisense air conditioners. Compatible with commercial line of air conditioners commercialized by Hisense. User Manual Issue Date: 12/2017
More informationNetwork Instrumentation Module Communications box NX-CB1 Communications adapter NX-CL1/NX-CR1 Terminal adapter NX-TL1/NX-TR1
No. CP-SS-1865E Network Instrumentation Module Communications box NX-CB1 Communications adapter NX-CL1/NX-CR1 Terminal adapter NX-TL1/NX-TR1 Overview Network Instrumentation Modules make optimal distributed
More informationPreface. Copyright 1997, Digital Electronics Corporation MS-DOS and Windows 95 are registered trademarks of the Microsoft Corporation.
Preface Thank you for purchasing the Profibus DP unit, hereafter referred to as the Profibus unit. This unit is intended for use with the Digital Electronics Corporation s GP-470/570/675/870 series touch
More informationOptimux-4T1 Four-Channel T1 Multiplexer
Data Sheet Optimux-4T1 Any Traffic Over Fiber Multiplexes four T1 channels over a fiber optics link with various fiber interfaces: multimode, single-mode (up to 120 km), and single-mode over single fiber
More informationMeasurement Systems Datascan Installation and User Guide
Measurement Systems Datascan Installation and User Guide Supplied By Contents Contents 1. INTRODUCTION... 1 1.1 GENERAL... 1 1.2 DATASCAN MODULE RANGE... 1 1.2.1 Measurement Processors... 1 1.2.2 Analog
More informationMODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE
INSTRUCTIONS MODBUS RTU MODULE for use with WSIQ2/WSE WorldWide Electric Corporation Phone: 1-8-88-2131 Fax: 1-8-711-1616 www.worldwideelectric.net Product Compatibility This communications module is suitable
More informationIO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1
IO-PT4 I/O Expansion Module 4 PT100 Inputs (-50 to 460 C) The IO-PT4 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 4 PT100 inputs
More informationATV320U04N4C variable speed drive ATV kW V - 3 phase - compact
Characteristics variable speed drive ATV320-0.37kW - 380...500V - 3 phase - compact Main Range of product Product or component type Product specific application Device short name Format of the drive Product
More informationisma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw
isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw www.gc5.pl Table of content 1 Introduction... 4 1.1 Revision history... 5 1.2 Safety rules... 5 1.3 Technical specifications... 6 1.4
More informationHan-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu
Contents Page Features... 19.02 Data interfaces... 19.03 Overview... 19.04 Cu... 19.06 F.O.... 19.08 Quintax 3 A... 19.10 RJ45 C... 19.12 USB / FireWire... 19.14 Han 4 A SC... 19.16 Hoods/Housings... 19.18
More informationNetwork Instrumentation Modules NX Digital Output Modules NX-DY1/DY2
CP-SS-1879E Network Instrumentation Modules NX Digital Output Modules NX-DY1/DY2 Overview Network Instrumentation Modules make optimal distributed configuration a reality. Distributed modules execute cooperative
More informationPROGRAMMABLE CONTROLLER. FP0 A/D Converter Unit. Technical Manual ARCT1F321E
PROGRAMMABLE CONTROLLER Technical Manual ARCT1F321E-2 2008.11 Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly,
More informationSerial Data DIN Fiber Link System
USER GUIDE RLH Industries, Inc. The leader in rugged fiber optic technology. U-120 2017A-0420 DIN Fiber Link System COMPACT, RUGGED & TEMPERATURE HARDENED Introduction The DIN Fiber Link system transports
More informationVersaMax IP Input Module
Module is used to accept digital input signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature Storage temperature Operating/storage humidity 60mm
More informationTerminal block 2 A 5 X 3. Specification
D Series Features Automatic communication speed recognition : Enables to recognize communication speed automatically when connecting with master Network Voltage monitoring : If PV is lower than SV, enables
More informationOperation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit
Fieldbus system PROFIBUS DP Compatible GW unit Operation Manual EX50-GPR URL http://www.smcworld.com Akihabara UDX 5F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: +8 3-507-89 Fax: +8 3-598-536
More informationBrief instruction. Version. 3en.
Brief instruction Version 3en www.helmholz.com Application and functional description The FLEXtra FO is primarily a normal PROFIBUS repeater with the capability of expansion by 2 (with FO-2) or 5 (with
More informationH Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION
H Series PLC EH-150 Analog input module EH-AXH8M Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction manual and all the
More informationCarbon Monoxide Sensor - ModBus
Introduction The CO Sensor uses an electrochemical sensor to monitor CO level in a range of 0 to 500 ppm and communicates via an RS-485 network configured for ModBus protocol. Before Installation Read
More informationATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21
Characteristics variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21 Main Range of product Product or component type Device application Device short name Variant Product destination
More information9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)
echnical data sheet EF24A- Communicative spring return actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx.
More informationDATA CONNECT ENTERPRISE
DATA CONNECT ENTERPRISE User s Manual IG202T and IGV23 Modem Document Number 520-01005-001 Rev. A DATA CONNECT Contents Contents... iii Figures... iv Chapter 1 Introduction... 5 Features...6 Applications...7
More informationR7D-RR8 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, 8 points MODEL. (DeviceNet)
INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, points (DeviceNet) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined
More informationW&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration
Manual Universal FO Interface Converter Model 81215 Release 1.0 Subject to error and alteration 13 10/2012 by Wiesemann & Theis GmbH Subject to error and alteration: Since it is possible that we make mistakes,
More informationATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet
Characteristics variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet Main Range of product Product or component type Device application Device short name Variant Product destination Mounting
More informationI/O Module with HART Communication (BU100H Series)
(Rev. 0) I/O Module with HART Communication (BU100H Series) The I/O Module with HART Communication (BU100H series) is a base-unit type analog input/output module with HART communication functionality for
More informationMedia Converters. Media Converters. Product Selection Guides
Product Selection Guides Media Converters Serial-to-Fiber Converter Selection Guide....................................-2 Serial-to-Serial Converter Selection Guide...................................-3
More informationCommunication & Networking
MicroSmart Master Module Capable of Connecting 62 Slaves Compliance with Ver. 2.1 specifi cations Digital and analog slaves can be connected. Configuration and slave monitoring can be done using LED indicators
More informationNPN/PNP DISCRETE HIGH SPEED INPUT & NPN TRANSISTOR OUTPUT MODULE
R7K4JML-E-DAFC64A INSTRUCTION MANUAL NPN/PNP DISCRETE HIGH SPEED INPUT & NPN TRANSISTOR OUTPUT MODULE ( 2 points each, tension clamp terminal block, MECHATROLINK-III use ) MODEL R7K4JML-E-DAFC64A BEFORE
More informationR1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)
INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If
More information10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual
10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter AMG9011G-H (-40 to 75C) User Manual www.amgsystems.com Content Overview...1 Introduction... 1
More information205 CPU NETWORK ADAPTER F2-UNICON
205 CPU NEWORK ADAPER F2-UNICON Network Adapter he F2-UNICON Network Adapter is used to place Automationdirect.com DL205 CPUs (except D2-230 and D2-250) on a RS-422 or RS-485 multi-drop network. he Network
More informationAD-8923-CC. Remote Controller (CC-Link) INSTRUCTION MANUAL 1WMPD B
AD-8923-CC Remote Controller (CC-Link) INSTRUCTION MANUAL 1WMPD4002124B 2013 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated
More informationASTAT XB/XBm Remote Operator
ASTAT XB/XBm Remote Operator User Manual 1 Introduction 1.1 Important User Information Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery
More informationVARMECA. Data communication systems. Réf GB / a
VARMECA Data communication systems Réf. 3427 GB - 2.33 / a - 07.01 The communication maestro A new networking solution VARMECA motors and geared motors, with integrated frequency inverter, offer a very
More informationUSB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.
USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD. Table of Contents Precautions... 1 Revision History... 2 Introduction... 2 1. Overview... 3 2. Power Supply... 3 3. Specifications...
More informationWindows 8 / 7 CONTENTS. USB to RS-422 Converter. Part Number: USB FEATURES. 2 SPECIFICATIONS. 2 CONNECTIONS.. 3
CONTENTS USB to RS-422 Converter Part Number: USB-422-1 INTRODUCTION 2 FEATURES. 2 SPECIFICATIONS. 2 PIN ASSIGNMENT 2 CONNECTIONS.. 3 DRIVER INSTALLATION QUICK GUIDE.. 3 DRIVER INSTALLATION EXAMPLES..
More informationCopyright: December 2017 Nidec Issue: E
General Information The manufacturer accepts no liability for any consequences resulting from inappropriate, negligent or incorrect installation or adjustment of the optional parameters of the equipment
More informationUSER S MANUAL Power Supply for Backplane Vdc
USER S MANUAL Power Supply for Backplane 20-30 Vdc D F 5 6 M E smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is available on our
More informationSECTION 10 Analog Input/Output Option Board
SECTION 10 Input/Output Option Board This section describes how to use Input/Output Option Board. 10-1 General Specifications.......................................... 506 10-2 Part Names...................................................
More informationNJ-Series Power Supply Unit NJ-PA/PD
NJ-Series Power Supply Unit CSM_NJ-PA_PD_DS_E_1_2 Powerful power supply unit to supply stable power to the NJ-series controller. Stable power supply is available from the NJ-series CPU Unit to each I/O
More informationADI12-8(USB)GY. Features. Packing List. F&eIt Series Isolated Analog Input Module for USB ADI12-8(USB)GY 1. Ver.1.02
F&eIt Series Isolated Analog Input Module for USB ADI128(USB)GY This product is a USB2.0 compatible terminal module that extends the analog input function of USB port of PCs. This product features 8ch
More informationMODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)
PC Recorders R1M Series PC RECORDER (contact output, 32 points) Functions & Features Industrial recorder on PC 32-point open collector outputs Easy system expansion via Modbus RTU Recorded data exportable
More informationHygroFlex HF3 Transmitters. User Guide
Page 1 of 27 HygroFlex HF3 Transmitters User Guide Page 2 of 27 Table of contents 1 Overview... 3 2 Mechanical configurations and dimensions... 4 2.1 Display option... 5 3 General description... 6 3.1
More informationRTD-NET Installation Instructions
LED3 SW1 LED4 RTD-NET Installation Instructions 0V +V POWER 15-24VDC English RTD-NET Installation Instructions 100.00 RTD-NET Control Interface realtime Control Systems REMC P1 P2 RS485 D-BUS DB DA GND
More informationManual Fiber Optic Interfaces
Manual Fiber Optic Interfaces Type 81210, 81211 61210, 61211 65210, 65211 41210 Release 1.4 Subject to error and alteration 31 06/2007 by Wiesemann & Theis GmbH Subject to error and alteration: Since it
More information