- 6 years ago
- Views:
Transcription
1 <<Contents>> <<Index>> GS M06H-0E FA Link H Modules FA-bus Modules Contents FLP0-0N FA Link H Module... FLP-0N Fiber-Optic FA Link H Module... 5 FLR0-0N Fiber-Optic FA-bus Module... 7 FLR0-0N Fiber-Optic FA-bus Type Module... 9 FLR0-W FA-bus Type Module... Yokogawa Electric Corporation GS M06H-0E Copyright 0 0th Edition Aug. 0
2 Blank Page
3 <<Contents>> <<Index>> FLP0-0N FA Link H Module The FLP0-0N FA Link H Module provides a high-speed network that allows information exchange between the Range-free Multi-controllers. The FLP0-0N is an FA link H interface module that provides a maximum of stations of data link (one module is counted as one station). - It allows a maximum of eight modules to be installed in a single main unit, to make up a multi-layer data link. The module can be accessed only from a designated CPU. - The number of link points can be specified arbitrarily for each CPU. - Bus-type communication channels are employed to facilitate the expansion of modules. - FA Link H Modules can be connected easily using a two-twisted-pair (-wire) shielded cable. Specification Number of stations max. Link relays 08 per module - FSP05/08 and FSP: 08 - FSP/5/8/5/5/66 and FSP7-S: 89 (non-continuous) - FSP8/58/59/67 and FSP76-7S: 6,8 (non-continuous) Link register 08 per module - FSP05/08 and FSP: 08 - FSP/5/8/5/5/66 and FSP7-S: 89 (non-continuous) - FSP8/58/59/67 and FSP76-7S: 6,8 (non-continuous) Maximum. Number of links per station Same as above. Link relay and link register assignments Link relay: on 6-relay basis Link register: on per register basis Number of modules FSP05/08 and FSP: max. FSP, FSP5, FSP8, FSP5, FSP8, FSP5, FSP58/59, FSP66/67, FSP7-S and FSP76-7S:8 max. Transmission speed 5 K, 50 K, 65 K or.5 Mbps (switch selectable) Transmission channel type -bus type Termination resistance 0 Ω at both ends (specified by a built-in switch when the line is terminated) Transmission distance km, 500 m, 50 m or 00 m (depends on transmission speed) Communication system Token-bus system Synchronization Frame synchronization Transmission format Conforms to HDLC. Modulation and encoding system NRZI system Error detection CRC-CCITT, timeout RAS features Error detection through local loopback, hardware self-diagnostics, special relay and register functions Transmission media Two-twisted-pair (-wire) shielded cable (AWG0) Current consumption 70 ma External connection -point terminal block, M.5 screws External dimensions 8.9 (W) x 00 (H) x 8. (D) mm (Note) Weight 0 g Surrounding air Operating :0 to 55 C temperature range Storage :-0 C to 75 C Surrounding humidity Operating :0 to 90% RH (non-condensing) range Storage :0 to 90% RH (non-condensing) Surrounding atmosphere Must be free of corrosive gases, flammable gases or heavy dust. Note: The given dimensions exclude protrusions (See External Dimensions for details). Note: FLP0-0N is not compatible with FSP7-N and FSP76-7N. Components and Functions Front View RDY SND ERR LP0-0N STATION NO. TERMINATOR OFF ON A B SG SHIELD Right Side View Indicators RDY: Lit when the internal circuit is functioning normally. SND: Lit when the module is sending data normally. ERR: Lit when an error occurs. Station No. switch (STATION No.): Sets a station number (0 to ). The factory setting is 0. Terminator switch (TERMINATOR): ON : Terminator is enabled. OFF: Terminator disabled. The factory setting is OFF. FA link H terminal block ( terminals, M.5 screws) Parameter switches Note: This figure is drawn with the panel cover removed. Factory No. No. Parameter OFF ON Switch setting OFF ON Transmission See table OFF No. OFF.5 Mbps 50 Kbps speed to the right. OFF ON 65 Kbps 5 Kbps Operation High Normal OFF mode speed (Not used) OFF All Rights Reserved. Copyright 0, Yokogawa Electric Corporation GS M06H-0E Aug., 0-00
4 <<Contents>> <<Index>> System Configuration Example. Connecting between Controllers The FLP0-0N can be used to configure a system in which communication speed can be as high as.5 Mbps. FLP0-0N FA Link H module FA Link H modules (.5 Mbps max., km max., stations). Connecting between Controllers, FA500 and µfa0 FLP0-0N FA Link H Module FLP0-0N FA Link H Module LP0-0N FA Link Module FA500 for FA500 µfa0 FA link 50 kbps (500 m max., stations) - Set the transmission speed of the FA Link H module to 50 kbps. External Connection Diagram Terminating resistor FA link H module A B SG SHIELD FA link H module A B SG SHIELD Maximum total cable length: S m FA link H module A B SG SHIELD Terminating resistor. The maximum total cable length (S) varies depending on the transmission speed used.. The SHIELD terminal of this module is internally connected to the FG terminal of the power supply module.. This module has a built-in terminator. When configuring the module at the end of the cable, set the terminator switch to ON. Cables Use two-pair (-wire) shielded cable (impedance 00 Ω ) when connecting FA Link H modules. Recommended cables: KM80- /KM8- (to be purchased separately). * For details on KM80- and KM8-, see YHLS Master Module, YHLS Slave Units and YHLS Communication Cables (for implementing high-speed remote I/O) (GS M06H6-0E). Operating Environment - The table below lists the CPU modules that can be used with this module. CPU Module FSP, FSP5 and FSP5 FSP05/ 08, FSP, FSP8, FSP8, FSP5/58/59, FSP66/67, FSP7-S, FSP76-7S Style No. and ROM Rev. S Rev. 8 or later Note: For the revision number of a CPU module, see the revision number label on the side panel. - The following table summarizes the requirements for the Ladder Diagram Support Program M, which can be used to set up the communications conditions of this module. All versions of the Ladder Programming Tool WideField, WideField and WideField can be used with this module. Ladder Diagram Support Revision Program M SF50-E Rev..08 or later Model and Suffix s Model Suffix Style Option FLP0-0N External Dimensions stations max. 5 k, 50 k, 65 k or.5 Mbps km, 500 m, 50 m or 00 m Unit:mm 00 FB05.VSD All Rights Reserved. Copyright 0, Yokogawa Electric Corporation GS M06H-0E Aug., 0-00
5 <<Contents>> <<Index>> 5 FLP-0N Fiber-optic FA Link H Module The FLP-0N Fiber-optic FA Link H Module is a high-speed network that allows information exchange between the Range-free Multi-controllers. The FLP-0N is a Fiber-optic FA link H interface module that provides a maximum of stations of data link (one module is counted as one station). - It allows a maximum of eight modules to be installed in a single main unit, to making up a multi-layer data link. The module can only be accessed from a designated CPU. - The number of link points can be specified arbitrarily for each CPU. - It supports daisy-chain configuration using fiber-optic cables. - It does not guarantee normal data link in the entire network if any one station on the network is powered off. Number of stations Link relays Link registers Max. number of links per station Link relay and link register assignments Number of modules Specification max. 08 per module - FSP05/08 and FSP: 08 - FSP/5/8/5/5, 66 and FSP7-S: 89 (non-continuous) - FSP8/58/59/67 and FSP76-7S:6,8 (non-continuous) 08 per module - FSP05/08 and FSP: 08 - FSP/5/8/5/5/66 and FSP7-S: 89 (non-continuous) - FSP8/58/59/67 and FSP76-7S: 6,8 (non-continuous) Same as above. Link relay: on 6-relay basis Link register: on per register basis FSP05/08 and FSP: max. FSP, FSP5, FSP8, FSP5, FSP8, FSP5, FSP58/59, FSP66/67, FSP7-S, FSP76-7S: 8 max. Transmission speed.5 Mbps Transmission channel type Daisy chain Transmission Maximum total distance: 0 km distance Maximum distance between stations: km Communication Token ring system Synchronization Frame synchronization Transmission format Conforms to HDLC. Modulation and encoding system NRZI system Error detection CRC-CCITT RAS feature Self-diagnostics -core optical fiber (hard plastic clad quartz Transmission media fiber-optic H-PCF) Current consumption 95 ma External dimensions 8.9 (W) x 00 (H) x 8. (D) mm Weight 0 g Surrounding air Operating :0 to 55 C temperature range Storage :-0 C to 75 C Surrounding humidity Operating :0 to 90% RH (non-condensing) range Storage :0 to 90% RH (non-condensing) Surrounding Must be free of corrosive gases, flammable atmosphere gases or heavy dust. Note: FLP-0N is not compatible with FSP7-N and FSP76-7N. Components and Functions Front View RDY SND ERR LP-0N STATION NO FALINK Right Side View Indicators RDY: Lit when the internal circuit is functioning normally. SND: Lit when the module is sending data normally. ERR: Lit when an error occurs. Station No. switch (STATION No.): Sets a station number (0 to ). The factory setting is 0. Fiber-optic connector Attach a dust cap in the port not used. O F F Parameter switches F0.VSD Note: This figure is drawn with the panel cover removed. No. Parameter OFF ON Factory setting Intermediate Terminal Intermediate station station station OFF (Not used) OFF Operation mode Normal High speed OFF (Not used) OFF All Rights Reserved. Copyright 0, Yokogawa Electric Corporation GS M06H-0E Aug., 0-00
6 <<Contents>> <<Index>> 6 Configuration Example External Dimensions Daisy-chain configuration Unit: mm FLP-0N Fiber-optic FA Link H module Fiber-optic FA Link H. The maximum distance between stations is km and the maximum total distance is 0 km.. The attached blank cover must be placed on any unused port of the terminating station. Operating Environment - There is no restriction on the type of CPU modules that can be used with this module. CPU Module Style No. and ROM Rev. FSP, FSP5 and FSP5 S Rev. 8 or later FSP05, FSP 08, FSP, FSP8, FSP8, FSP5/58/59,FSP66/67, FSP7-S, FSP76-7S Note: For the revision number of a CPU module, see the revision number label on the side panel. - The following table summarizes the requirements for the Ladder Diagram Support Program M, which can be used to set up the communications conditions of this module. All versions of the Ladder Programming Tool WideField, WideField and WideField can be used with this module. Ladder Diagram Support Revision Program M SF50-E Rev..08 or later Model and Suffix s Model Suffix Style Option FLP -0N stations max. Maximum total distance: 0 km Maximum distance between stations: km.5mbps Optional Accessories The customer should prepare fiber-optic cables satisfying the requirements listed below when connecting between Fiber-optic FA Link H modules. See Fiber-optic Cables (GSM06C9-0E) for details on fiber-optic cables. for Fiber-optic Cable Cores Yokogawa Cable Model Number KM60 KM60,KM6,KM6,KM65 Fiber-optic Cable Model No.(Size) DK-HPF00/0 CCV-HC-0/07 Fiber-optic Cable type SI type SI type Vendor SWCC Showa Sumitomo Electric Cable System Core diameter 00±5μm Clad diameter μm Transmission loss 7.0dB/km Max. 7dB/km Max. (λ=0.85μm,ta=5 ) (λ=0.8μm,ta=5 ) :Step-index optical fiber for Fiber-optic Cable Connectors Yokogawa Cable Model Number Optical connectors Model No. Vendor KM60 KF-07 SWCC Showa Cable Systems lever lock bonding, polished KM65 CF-0 CF-07 Sumitomo Electric lever lock, crimping, cut KM60,KM6 KM6 CF-00H CF-07H Sumitomo Electric lever lock bonding, polished All Rights Reserved. Copyright 0, Yokogawa Electric Corporation GS M06H-0E Aug., 0-00
7 <<Contents>> <<Index>> 7 FLR0-0N Fiber-optic FA-bus Module The FLR0-0N is an interface module for constructing a system that requires distributed placement of multiple modules. The user can build up an efficient remote I/O system by installing FLR0-0N modules in the main- and sub-units and connecting them via a fiber-optic FA-bus (fiber-optic cable). - With the 0-Mbps high-speed communications capability of the FLR0-0N, the user does not have to worry about the I/O refresh time in ladder programming. - All I/O module types and most special module types* can be installed in sub-units and accessed just like modules installed in the main unit. *:See "Restrictions on System Configuration" - No specific communications setup (environment setup) is required. - The optical transmission system makes the FLR0-0N highly immune to noise. Specification Transmission speed 0 Mbps -core optical fiber (hard plastic clad Transmission media quartz fiber-optic H-PCF) Transmission distance Maximum total distance: 00 m Maximum distance between stations: 00 m Transmission configuration Star Maximum number of sub-units (systems) 7 (systems) Shutdown I/O contact output on transmission RAS features channel error, reporting of transmission channel error location Current consumption 0 ma External dimensions 8.9 (W) x 00 (H) x 8. (D) mm Weight 00 g Surrounding air Operating :0 to 55 C temperature range Storage :-0 C to 75 C Surrounding humidity Operating :0 to 90% RH (non-condensing) range Storage :0 to 90% RH (non-condensing) Surrounding atmosphere Must be free of corrosive gases, flammable gases or heavy dust. Note: The maximum number of systems when µ-bus master station module are used is system less than the value above for each µ-bus master station. Components and Functions Front View RDY ERR LR0-0N REMOTE SUB UNIT NO. Right Side View Indicators RDY: Lit when the internal circuit is functioning normally. ERR: Lit when the module fails to detect an input signal from a port. Unit No. switch (SUB UNIT No.) Sets a unit number (0 to 7). 0 : Unit number of the main unit -7: Unit number of the sub-units 8,9: Cannot be used. Fiber-optic connector O F F Condition switches (-pole DIP switch) No. ON OFF Factory Setting Shutdown output Hold output OFF ON *: Valid only for output modules installed in a subunit. Note: This figure is drawn with the panel cover removed. All Rights Reserved. Copyright 0, Yokogawa Electric Corporation GS M06H-0E Aug., 0-00
8 <<Contents>> <<Index>> 8 System Configuration Example Star Configuration Unit No. 0 Main unit Unit No. Unit No. Unit No. Operating Environment There is no restriction on the type of CPU modules that can be used with this module. Model and Suffix s Model Suffix Style Option FLR0-0N Maximum total distance: 00 m Maximum distance between stations: 00 m Sub-units* FLR0-0N Fiber-optic FA-bus module for External Dimensions Unit: mm Daisy-chain + Star Configuration Unit No. 0 Main unit FA500 Unit No. Unit No. Unit No. Sub-units* FA500 Unit No. 5 *: Maximum number of sub-units: 7 Unit No. FLR0-0N Fiber-optic FA-bus module for LR0-0N Fiber-optic FA-bus module for FA500 Restrictions on System Configuration Maximum total distance Number of connectable sub-units Number of fiber-optic FA-bus modules installable in a main unit Number of fiber-optic FA-bus modules installable in a sub-unit Modules installable in a sub-unit 00 m 7 max. 7 max. (no restrictions on the installation location) (no restrictions on the installation location) All I/O modules, and special modules except FLP, FLE0, FLX0 and FNX0 modules. Optional Accessories Prepare fiber-optic cables satisfying the requirements listed below when connecting Fiber-optic FA-bus modules for extension. See Fiber-optic Cables (GS M06C9-0E) for details on fiber-optic cables. for Fiber-optic Cable Cores Yokogawa Cable Model Number KM60 KM60,KM6,KM6,KM65,KM69 Fiber-optic Cable Model No. (Size) DK-HPF00/0 CCV-HC-0/07 Fiber-optic Cable type SI type SI type Vendor SWCC Showa Sumitomo Electric Cable System Core diameter 00±5μm Clad diameter μm Transmission loss 7.0dB/km Max. 7dB/km Max. (λ=0.85μm,ta=5 ) (λ=0.8μm,ta=5 ) :Step-index optical fiber for Fiber-optic Cable Connectors Yokogawa Cable Model Number Optical connectors Model No. Vendor KM60 KF-07 SWCC Showa Cable Systems lever lock bonding, polished KM65 CF-0 CF-07 Sumitomo Electric lever lock, crimping, cut KM60,KM6 KM6,KM67,KM69 CF-00H CF-07H Sumitomo Electric lever lock bonding, polished All Rights Reserved. Copyright 0, Yokogawa Electric Corporation GS M06H-0E Aug., 0-00
9 <<Contents>> <<Index>> 9 FLR0-0N Fiber-optic FA-bus Type Module The FLR0-0N is an interface module for constructing a system that requires distributed placement of multiple modules. The user can build up an efficient remote I/O system by installing FLR0-0N modules in the main- and sub-units and connecting them via a fiber-optic FA-bus (fiber-optic cable). - With the 0-Mbps high-speed communication capability of the FLR0-0N, the user does not have to worry about the I/O refresh time in ladder programming. - All I/O module types and most special module types* can be installed in sub-units and accessed just like modules installed in the main unit. *:See "Restrictions on System Configuration" - No specific communication setup (environment setup) is required. - The optical transmission system makes the FLR0-0N highly immune to noise. - A single sub-unit can be segmented into a maximum of 8 stations. - A -port (send/receive) system allows daisy-chain configuration. - The loop system is switched into two pairs of daisy-chain systems when a disconnection occurs in the system, thereby improving system reliability. Specification Transmission speed 0 Mbps -core optical fiber (hard plastic clad quartz Transmission media fiber-optic H-PCF) Transmission distance Maximum distance between stations: 500 m Maximum total distance:. km ( stations) Transmission configuration Star, daisy chain, loop Maximum number of sub-stations 56 Maximum number of systems 7 (Note) Maximum number of sub-stations per system Maximum total distance per system. km ( stations) Maximum distance between stations 500 m Shutdown I/O contact output on transmission RAS features channel error, reporting of transmission channel error location Current consumption 60 ma External dimensions 8.9 (W) x 00 (H) x 8. (D) mm Weight 0 g Surrounding air Operating :0 to 55 C temperature range Storage :-0 C to 75 C Surrounding humidity Operating :0 to 90% RH (non-condensing) range Storage :0 to 90% RH (non-condensing) Surrounding atmosphere Must be free of corrosive gases, flammable gases or heavy dust. Note: The maximum number of systems when µ-bus master station module are used is system less than the value above for each µ-bus master station. Components and Functions Front View RDY ERR ERR LR0-0N REMOTE SUB UNIT NO. LEFT SLOT NO. Indicators RDY: Lit when the internal circuit is functioning normally. ERR, : Lit when the module fails to ERR detect an input signal from a port. Unit No. switch (SUB UNIT No.): Sets a unit number (0 to 7). 0 : Unit number of the main unit -7 : Unit number of sub-units 8, 9 : Cannot be used. First slot number switch (LEFT SLOT NO.) Used to set the first slot number (hexadecimal) of the base module. Condition Switches Fiber-optic connector Attach a dust cap, in not using the port. No. Meaning OFF ON Factory set * Hold/reset output on Hold * Shutdown communication error output output ON Port used Port Both ports * OFF Channel configuration Daisy chain or star Loop OFF Reserved OFF *: Valid only for output modules installed in a sub-unit. *: Continues operation if transmission channel has been secured and system operation is continued. *: Both port and port are used. Light Power Setup Switches Distance between stations No. Meaning (Fiber-optic cable length) (m) 5 Port OFF ON OFF ON intensity OFF OFF ON ON 7 Port OFF ON OFF ON intensity OFF OFF ON ON Right Side View O F F 5 O 6 F 7 F 8 Note: This figure is drawn with the panel cover removed. All Rights Reserved. Copyright 0, Yokogawa Electric Corporation GS M06H-0E Aug., 0-00
10 <<Contents>> <<Index>> 0 System Configuration Example Daisy-chain configuration main unit FLR0-0N Fiber-optic FA-bus Type module Fiber-optic FA-bus Substation Configuration - Substation Configuration Example The user can configure two or more sub-stations by splitting a sub-unit using the fiber-optic FA-bus type. A sub-unit logically consists of 6 slots. A maximum of 7 sub-units can be used with the main unit. Main unit Slot 6 stations max. Sub-unit Sub-unit Sub-unit 7 Loop configuration main unit FLR0-0N Fiber-optic FA-bus Type module Fiber-optic FA-bus - Split Patterns Sub-units can be split in several patterns. Select an appropriate pattern according to the configuration of your system. stations max. Split pattern FBU06 FBU06 FBU0 FBU0 FBU09 FBU0 FBU0 Slot No. FBU06 FBU0 FBU06 FBU0 FBU0 FBU0 FBU0 Number of sub-stations Free Free Free Free FBU0 FBU0 FBU0 FBU0 FBU0 Free FBU0 Free FBU0 Free FBU0 Free 8 Restrictions on System Configuration Number of Fiber-optic FA-bus Type modules installable in a master station Number of Fiber-optic FA-bus Type modules installable in a sub-station Modules installable in a sub-station 5 Max. All I/O modules, and special modules except FLP, FLE0, FLX0 and FNX0 modules. When pattern () is used, for example, it is possible to connect together up to 7 sub-units, providing a maximum of stations. A -station system (maximum configurable system) can be configured by combining 6 sets of pattern (5) and set of pattern (6). The number of I/O modules that can be installed in pattern (6) is module per sub-station. All Rights Reserved. Copyright 0, Yokogawa Electric Corporation GS M06H-0E Aug., 0-00
11 <<Contents>> <<Index>> Number of s and Maximum Total Distance (m) Maximum Total Distance (m) Number of Daisy-chain Loop Subconfiguration configuration stations Number of Substations Maximum Total Distance (m) Daisy-chain Loop configuration Do not lay cables such that the actual fiber-optic cable length exceeds the Maximum total distance, or the distance between two stations exceeds the maximum distance allowed between stations (500 m). External Dimensions Unit: mm Operating Environment - The following table lists the type of CPU modules that can be used with this module. CPU Module Style No. and ROM Rev. * FSP, FSP5 and FSP5 S Rev. 8 or later * FSP05/08, FSP, FSP8, FSP8, FSP5/58/59, FSP66/67, FSP7/76 FBP0, FBP0 and FFP6 *: For the revision number of a CPU module, see the revision number label on the side panel. *: Supports logging of transmission channel error location. - The following table summarizes the requirements for the Ladder Diagram Support Program M, which can be used to set up the communications conditions of this module. All versions of the Ladder Programming Tool WideField and WideField can be used with this module. Ladder Diagram Support Program M Revision SF50-E Rev..08 or later *: Supports logging of transmission channel error location. - The following table lists the type of base modules that can be used with this module. Base Module ID Mark FBU0 R 0 or later FBU05 FBU06 R 0 or later FBU09 FBU FBU6 Model and Suffix s Model Suffix Style Option FLR0-0N Maximum total distance:. km Maximum distance between stations: 500 m Optional Accessories Prepare fiber-optic cables satisfying the requirements listed below when connecting Fiber-optic FA-bus Type modules for extension. See Fiber-optic Cables (GS M06C9-0E) for details on fiber-optic cables. for Fiber-optic Cable Cores Yokogawa Cable Model Number Fiber-optic Cable Model No. (Size) Fiber-optic Cable type Vendor Core diameter KM60 KM60,KM6, KM6,KM65,KM69 KM67 DK-HPF00/0 CCV-HC-0/07 CCV-HG-0/08 SI type SI type GI type SWCC Showa Sumitomo Electric Cable System 00±5μm Clad diameter Transmission loss 7.0dB/km Max. (λ=0.85μm, Ta=5 ) :Step-index optical fiber :Graded-index optical fiber -0 μm 7dB/km Max. (λ=0.8μm, Ta=5 ) 8dB/km Max. (λ=0.8μm, Ta=5 ) for Fiber-optic Cable Connectors Yokogawa Cable Model Number Optical connectors Model No. Vendor KM60 KF-07 SWCC Showa Cable Systems lever lock bonding, polished KM65 CF-0 CF-07 Sumitomo Electric lever lock, crimping, cut KM60,KM6 KM6,KM67,KM69 CF-00H CF-07H Sumitomo Electric lever lock bonding, polished All Rights Reserved. Copyright 0, Yokogawa Electric Corporation GS M06H-0E Aug., 0-00
12 0 5 <<Contents>> <<Index>> FLR0-W FA-bus Type Module The FLR0-W is an interface module for constructing a system that requires distributed placement of multiple modules. The user can build up an efficient remote I/O system by installing FLR0-W modules in the main- and sub-units and connecting them via a FA-bus. - With the 0-Mbps high-speed communication capability of the FLR0-W, the user does not have to worry about the I/O refresh time in ladder programming. - All I/O module types and most special module types* can be installed in sub-units and accessed just like modules installed in the main unit. *:See "Restrictions on System Configuration" - Both daisy-chain and loop configuration options are supported. - The loop system is switched into two pairs of daisy-chain systems when a disconnection occurs in the system. Specification Transmission speed 0 Mbps two-pair (-wire) shielded cable Transmission media (impedance 00Ω) Maximum total distance:70m Transmission distance Maximum distance between stations: 0 m Transmission configuration Star, daisy chain, loop Maximum number of subunits (systems) 7 (Note) Shutdown I/O contact output on transmission RAS features channel error, reporting of transmission channel error location Must be installed inside panel enclosure or Installation location system Current consumption 0 ma External dimensions 8.9 (W) x 00 (H) x 8. (D) mm Weight 05 g Surrounding air Operating : 0 to 55 C temperature range Storage : -0 C to 75 C Surrounding humidity Operating : 0 to 90% RH (non-condensing) range Surrounding atmosphere Storage : 0 to 90% RH (non-condensing) Must be free of corrosive gases, flammable gases or heavy dust. Note: The maximum number of systems when µ-bus master station modules are used is system less than the value above for each µ-bus master station. The combined maximum number of systems is 7 when FA bus- modules are used with Fiber-optic FA bus- modules and Fiber-optic FA bus modules. Components and Functions Front View RDY ERR ERR LR0-W REMOTE R- R+ T- T+ 7 6 SHIELD SUB UNIT NO. R- R+ T- T+ Right Side View Front Indicators RDY ERR, ERR : Lit when the internal circuit is functioning normally. : Lit when the module fails to detect an input signal from a port. Unit No. Indicator 0 : Unit number of the main unit -7 : Unit number of sub-units Communication port O F F Rear This figure is drawn with the panel cover removed. Parameter switches Condition Switches SW No. Meaning OFF ON Factory setting * Hold/reset output on communication error * Hold output Shutdown output ON Port used Port Both ports * OFF Channel configuration Daisy chain or star Loop OFF Reserved OFF *: Valid only for output modules installed in a sub-unit. *: Continues operation if transmission channel has been secured and system operation is continued. *: Both port and port are used. All Rights Reserved. Copyright 0, Yokogawa Electric Corporation GS M06H-0E Aug., 0-00
13 <<Contents>> <<Index>> System Configuration Example Daisy-chain configuration Main unit FLR0-W FA-bus Type module FA-bus Type Operating Environment - The following table lists the type of CPU modules that can be used with this module. CPU Module Style No. and ROM Rev. * FSP, FSP5 and FSP5 S Rev. 8 or later * FSP05, FSP08, FSP, FSP8, FSP8, FSP5, FSP58/59, FSP66/67, FSP7/76 FBP0, FBP0 and FFP6 *: For the revision number of a CPU module, see the revision number label on the side panel. *: Supports logging of transmission channel error location. Loop configuration Main unit FLR0-W FA-bus Type module FA-bus Type 7 stations max. 7 stations max. - The following table summarizes the requirements for the Ladder Diagram Support Program M that can be used with the module. All versions of the Ladder Programming Tool WideField, WideField and WideField can be used with this module. Ladder Diagram Support Program M Revision SF50-E Rev..08 or later * *: Supports logging of transmission channel error location. - All versions of the Ladder Programming Tool WideField can be used with this module. Model and Suffix s Model Suffix Style Option FLR0 -W External Dimensions Maximum total distance: 70 m Maximum distance between stations: 0 m Restrictions on System Configuration Number of FA-bus Type modules 7 installable in a main unit Number of FA-bus Type modules installable in a subunit All I/O modules, and special modules except FLP, Modules installable in a subunit FLE0, FLX0 and FNX0 modules, Cables Use two-pair (-wire) shielded cable (impedance 00Ω) when connecting FA-bus Type modules. Recommended cable: KM80- (tested for noise immunity, to be purchased separately) * For details on KM80-, see GSM6H6-0E. All Rights Reserved. Copyright 0, Yokogawa Electric Corporation GS M06H-0E Aug., 0-00
14 <<Contents>> <<Index>> s to Specify When Ordering. Model and suffix codes All Rights Reserved. Copyright 0, Yokogawa Electric Corporation Subject to change without notice. GS M06H-0E Aug., 0-00
FA-M3 FA Link H Modules FA-bus Modules. Contents. F3LP02-0N FA Link H Module F3LP12-0N Fiber-Optic FA Link H Module... 5
GS M06H-0E A Link H Modules A-bus Modules Contents LP0-0N A Link H Module... LP-0N iber-optic A Link H Module... 5 LR0-0N iber-optic A-bus Module... 7 LR0-0N iber-optic A-bus Type
More informationUser s Manual FA Link H Module Fiber-optic FA Link H Module Model: F3LP02-0N, F3LP12-0N
User s Manual FA Link H Module Fiber-optic FA Link H Module Model: F3LP02-0N, F3LP12-0N IM 34M06H43-01E IM 34M06H43-01E 5th Edition Blank Page Applicable Product i Range-free Multi-controller FA-M3 - Model
More informationGeneral Specifications
General GS 34M06C01-01E FA-M3 Basic Modules (Base, Power Supply, CPU Modules and ROM Packs) F3BU04-0N, F3BU06-0N, F3BU05-0D, F3BU09-0N, F3BU13-0N, F3BU16-0N F3PU10-0S, F3PU0-0S, F3PU30-0S,
More informationYHLS Master Module. User s Manual. Applicable Modules: Model Code Model Name F3LH01-1N YHLS Master Module F3LH02-1N YHLS Master Module
User s Manual YHLS Master Module IM 34M06H46-04E Applicable Modules: Model Code Model Name F3LH01-1N YHLS Master Module F3LH02-1N YHLS Master Module Yokogawa Electric Corporation IM 34M06H46-04E 2nd Edition
More informationAnalog Input/Output Modules
User s Manual Analog Input/Output Modules Addendum Manual No. :IM 34M06H11-01E Manual Title :Analog Input/Output Modules Edition :1st Edition With the adoption of the CE Marking conformance declaration
More informationGeneral. Specifications. F3NC96-0N Positioning Module (with MECHATROLINK-II Interface) GS 34M6H60-02E. General. Specification
General Specifications GS 34M6H60-02E F3NC96-0N Positioning Module (with MECHATROLINK-II Interface) General This positioning module is to be installed on the base unit of a FA M3 range free controller
More informationAppendix G. CJ1W-CIF11 RS-422A Converter
CJ1W-CIF11 RS-422A Converter The CJ1W-CIF11 RS-422A Converter connects directly to a CS/CJ-series RS-232C port and converts RS- 232C to RS-422A/485. Specifications General Specifications Item Specification
More informationYHLS Master Module. User s Manual. Applicable Modules: Model Code Model Name F3LH02-0N YHLS Master Module. IM 34M6H46-01E 1st Edition IM 34M6H46-01E
User s Manual YHLS Master Module IM 34M6H46-01E Applicable Modules: Model Code Model Name F3LH02-0N YHLS Master Module Yokogawa Electric Corporation IM 34M6H46-01E 1st Edition Applicable Product: i Range-free
More informationTOSLINE-S20 Active Star Coupler Instruction Manual
TOSLINE - S20 Active Star Coupler Instruction Manual September, 1995 Toshiba International Corporation UM-TLS20**-E004 Table of Contents 1. Introduction... 2 2. Overview... 3 3. Specifications... 4 3.1
More informationPROFIBUS Repeater PRC P PROFIBUS Converter PCF PF P PROFIBUS Converter PCF PF P20.05
Contents chapter age General information............................... 00 Repeater.......................................... 10 Repeater RC 67-10............................... 10.01 Converter.........................................
More informationR6-NC1 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL CC-Link INTERFACE MODULE MODEL. (CC-Link Ver.1.10; for 16-point analog signals)
INSTRUCTION MANUAL CC-Link INTERFACE MODULE (CC-Link Ver..; for -point analog signals) MODEL R-NC BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received
More informationBEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL PNP TRANSISTOR OUTPUT MODULE, 16 points (MECHATROLINK-I / -II, short circuit protection)
INSTRUCTION MANUAL PNP TRANSISTOR OUTPUT MODULE, 16 points (MECHATROLINK-I / -II, short circuit protection) R7ML-DC16D MODEL R7ML-DC16D BEFORE USE... Thank you for choosing M-System. Before use, please
More informationFL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B
Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide
More informationRemote I/O Product Specification
Table of Contents 1. Product Overview... 1 1.1 Product List:... 1 1.1.1 Coupler List:... 1 1.1.2 Digital I/O List:... 1 2. Fieldbus Coupler... 2 2.1 CANopen Specifications... 2 2.2 Ethernet TCP/IP Specifications...
More informationNX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration
NX-series SSI Input Unit CSM DS_E_1_1 Read position information from encoders with Synchronous Serial Interface (SSI). Process SSI encoder input data using the MC Function Modules of the NJ-series Machine
More information1) Indicates that the identified danger WILL cause physical and property damage.
CC-Link Ver.1.10 FX2N-16CCL-M CC-Link SYSTEM MASTER BLOCK HARDWARE MANUAL JY992D93201D This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation
More informationRemote I/O Product Specification
Table of Contents 1. Product Overview... 1 1.1 Product List:... 1 1.1.1 Coupler List:... 1 1.1.2 Digital I/O List:... 1 2. Fieldbus Coupler... 2 2.1 CANopen Specifications... 2 2.2 Ethernet TCP/IP Specifications...
More informationT1K MODBUS Base Controller Specifications
Base Controller 1 2 In This Chapter.... Base Controller Setting the DIP Switches Setting the Rotary Address Switches Port Pin out and Wiring RJ12 Serial Port Pin out and Wiring 2 2 Base Controller General
More informationInstallation and Setup
Installation and Setup 1 In This Chapter Installing the H PBC The Profibus Network Configuring the Controller Installing the H PBC Setting the Node Address Setting the Node Address Profibus DP is usually
More informationAppendix 3 Using NS-AL002 Converters
Appendix 3 Using Converters The RS-232C/RS-422A Converter is connected directly to RS-232C port A or B of the, and converts RS-232C communications to RS-422A/RS-485. Any of the Converters listed in Appendix
More informationInstallation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module
Installation and Setup 1 2 In This Chapter.... Installing the H0 PSCM The Profibus Network Configuring the Module 2 2 Installing the H0 PSCM Remove the Slot Cover The first step in installing the option
More informationFL MC 2000E (SM40) LC
IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features
More informationMODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)
PC Recorders Series PC RECORDER (4 totalized counter inputs, 8 contact inputs and outputs) Functions & Features Industrial recorder on PC Totalized counter inputs Counts stored in E 2 PROM Easy system
More informationMODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series
Remote I/O R3 Series FL-net INTERFACE MODULE (OPCN-2, Ver.2. supported) Functions & Features FL-net (OPCN-2), Ethernet based, controller level network, compatible remote I/O 1 Mbps/1 Mbps cyclic transmission
More informationMODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)
MODEL: R-NE Remote I/O R Series ETHERNET INTERFACE MODULE (Modbus/TCP) 7. (.8) 9 (.9) (.) mm (inch) MODEL: R-NE-[][] ORDERING INFORMATION Code number: R-NE-[][] Specify a code from below for each [] and
More information1 1 Getting Started $ "% # + %#! & %! + % $!% +!% $% # * %&# $ +!% ' *!# * %&# $ + $$ %!% "&% &%"&% # $$ $ +!( % " % $!%! %$ + $) % "$!# %% "!
2 Manual Introduction The Purpose of this Manual This manual shows you how to install, program, and maintain the equipment. It also helps you understand the system operation characteristics. Who Should
More informationEtherCAT Remote I/O Terminal GX series
EtherCAT Remote I/O Terminal GX series Digital I/O Terminal 2-tier Terminal Block Type Digital I/O Terminal 3-tier Terminal Block Type Digital I/O Terminal e-con Connector Type Analog I/O Terminal 2-tier
More informationIO-AO6X I/O Expansion Module 6 Isolated Analog Outputs
IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated
More informationPRODUCT OVERVIEW. Redundant CPUs. High speed µs processing. Redundant power supplies. Large 62K-word program and 24Kword data memory capacity
PRODUCT OVERVIEW ` CVM1 Series The CVM1D Duplex system s redundancy is a new option in Omron s large controllers. Two redundant CPUs and power supplies ensure that processes will continue operation when
More informationR3-NE1 ETHERNET INTERFACE MODULE MODEL. Remote I/O R3 Series. (Modbus/TCP)
Remote I/O R Series ETHERNET INTERFACE MODULE (Modbus/TCP) MODEL R-NE MODEL & SUFFIX CODE SELECTION R NE MODEL POWER INPUT K : V AC L : V AC R : V DC N : No power supply * *. Choose N (no power supply)
More informationHITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions
HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction
More informationPHOENIX CONTACT - 10/2009
Factory Line Switches With Standard Functions AUTOMATIONWORX Data Sheet PHOENIX CONTACT - 10/2009 Description The range of Factory Line switches with standard functions in numerous versions can be used
More informationH704-42(H)(E), H704-42/1(H)(E)
POWER MONITORING INSTALLATION GUIDE H704-42(H)(E), H704-42/1(H)(E) Branch Current Monitor DANGER NOTICE Installer's Specifications General: Operating Temp. Range 0 to 60 C (32 to 140 F) (
More informationPROFIBUS-DP Interface Module
User s Manual PROFIBUS-DP Interface Module IM 34M6H34-01E Yokogawa Electric Corporation IM 34M6H34-01E 1st Edition Applicable Product: i l Range-free Multi-controller FA-M3 - Model code : F3LB01-0N - Name
More informationMODEL: R2K-1 SEN TRONIC AG. R2K Series
1 MODEL: R2K-1 R2K Series /RS-485 CONVERTER Functions & Features Bidirectional converter between and RS-485 used when connecting Modbus RS-485 devices to a PC CE marking Standard: Conforms to, EIA Transmission
More informationNX Interface Module. User s Manual. Applicable Modules: Model Code Model Name F3NX01-0N NX Interface Module F3NX01-1N NX Interface Module
User s Manual NX Interface Module IM 34M06H29-01E Applicable Modules: Model Code Model Name F3NX01-0N NX Interface Module F3NX01-1N NX Interface Module Yokogawa Electric Corporation IM 34M06H29-01E 2nd
More informationCommunication Controller CC-Link/CPL Converter CMC10A
No. CP SS 1766E Communication Controller CC-Link/CPL Converter CMC10A The communication controller CMC10A is a converter designed for the communication between Yamatake's digital indicating controller
More informationEX-RC1 Remote I/O Adapter
EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter
More informationDLS-E2 TELEMETERING UNIT BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (16 contact inputs & 16 open collector outputs)
INSTRUCTION MANUAL TELEMETERING UNIT ( contact inputs & open collector outputs) MODEL DLS-qE DLS-E BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received
More informationRTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM
RTD-RA Installation Instructions 37.50 LEDS 4 3 2 1 D English Installation Instructions 80.00 80.00 ALL DIMENSIS IN MM C realtime Control Systems A B LEDS 4 3 2 1 D S21 J3 J6 1 2 3 4 J5 5 6 7 0V S1 0V
More informationEX-RC1 Remote I/O Adapter
EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter
More informationMED102A. Industrial Serial to Single-mode Fiber Converter
MED102A - 0708 pg. 1 / 5 MED102A Industrial Serial to Single-mode Fiber Converter Data Rates up to 115.2 kbps 9 Mile (15 km) Range 10 to 48 VDC Input Voltage Wide Operating Temperature 2000V Isolation
More informationPreface. Copyright 1997, Digital Electronics Corporation MS-DOS and Windows 95 are registered trademarks of the Microsoft Corporation.
Preface Thank you for purchasing the Profibus DP unit, hereafter referred to as the Profibus unit. This unit is intended for use with the Digital Electronics Corporation s GP-470/570/675/870 series touch
More informationMODEL: GR8-EM. Communication Adaptor GR8 Series
Communication Adaptor GR8 Series Ethernet/RS-485 Adaptor (Modbus use) Functions & Features Bidirectional protocol converter for Modbus/TCP (Ethernet) and Modbus RTU (RS-485) Fast response time thanks to
More informationFiber optic converter audio and CAN TA OPERATION MANUAL
Fiber optic converter audio and CAN TA-110.1 IOA110-1 March 2009 LANEX S.A., Technical support: tel. ul.ceramiczna 8, 20-150 Lublin tel. +48 81 443 96 36 Contents 1. General Characteristics.... 5 1.1.
More informationEX-RC1 Remote I/O Adapter
EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter
More informationOperation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit
Fieldbus system PROFIBUS DP Compatible GW unit Operation Manual EX50-GPR URL http://www.smcworld.com Akihabara UDX 5F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: +8 3-507-89 Fax: +8 3-598-536
More informationInstruction Manual TOSLINE-S20LP. T2N/T3H stations
Instruction Manual TOSLINE-S20LP T2N/T3H stations REQUIREMENTS Keep this instruction manual where it can be easily referred to by users and those responsible for the equipment. Read this instruction manual
More informationExpansion Module HZS 541-1S
Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs
More informationR3-GE1 BEFORE USE... INSTALLATION POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP)
INSTRUCTION MANUAL ETHERNET INTERFACE MODULE (Modbus/TCP) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have
More informationOptimux-4T1 Four-Channel T1 Multiplexer
Data Sheet Optimux-4T1 Any Traffic Over Fiber Multiplexes four T1 channels over a fiber optics link with various fiber interfaces: multimode, single-mode (up to 120 km), and single-mode over single fiber
More informationRemote I/O Product Specification
Table of Contents 1. Product Overview... 1 1.1 Product List:... 1 1.1.1 Coupler List:... 1 1.1.2 1.1.3 Digital I/O List:... 1 Analog I/O List:... 1 2. Fieldbus Coupler... 2 2.1 CANopen Specifications...
More informationR1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)
INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If
More informationBrief instruction. Version. 3en.
Brief instruction Version 3en www.helmholz.com Application and functional description The FLEXtra FO is primarily a normal PROFIBUS repeater with the capability of expansion by 2 (with FO-2) or 5 (with
More informationATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21
Characteristics variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21 Main Range of product Product or component type Device application Device short name Variant Product destination Mounting
More informationMeasurement Systems Datascan Installation and User Guide
Measurement Systems Datascan Installation and User Guide Supplied By Contents Contents 1. INTRODUCTION... 1 1.1 GENERAL... 1 1.2 DATASCAN MODULE RANGE... 1 1.2.1 Measurement Processors... 1 1.2.2 Analog
More informationCat. No. W434-E1-01. SYSMAC CVM1/CV Series CVM1-LK401. PC Link Unit OPERATION MANUAL
Cat. No. W434-E1-01 SYSMAC CVM1/CV Series CVM1-LK401 PC Link Unit OPERATION MANUAL CVM1-LK401 PC Link Unit Operation Manual Produced July 2004 iv Notice: OMRON products are manufactured for use according
More informationMODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)
PC Recorders R1M Series PC RECORDER (contact output, 32 points) Functions & Features Industrial recorder on PC 32-point open collector outputs Easy system expansion via Modbus RTU Recorded data exportable
More informationIO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1
IO-PT4 I/O Expansion Module 4 PT100 Inputs (-50 to 460 C) The IO-PT4 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 4 PT100 inputs
More informationATV340D18N4E variable speed drive - 18kW- 400V - 3 phases - ATV340 Ethernet
Characteristics variable speed drive - 18kW- 400V - 3 phases - ATV340 Ethernet Main Range of product Product or component type Device application Device short name Variant Product destination Mounting
More informationPHOENIX CONTACT - 11/2008
The small form-factor pluggable module (SFP module) is a plug-in input/output module for fiber optics that is used in Gigabit Ethernet AUTOMATION Data Sheet 7762_en_01 PHOENIX CONTACT - 11/2008 1 Description
More informationPROGRAMMABLE CONTROLLER. FP0 A/D Converter Unit. Technical Manual ARCT1F321E
PROGRAMMABLE CONTROLLER Technical Manual ARCT1F321E-2 2008.11 Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly,
More informationTOSLINE-S20. Active Star Coupler(ASC25) Instruction Manual
6 F 3 B 0 3 6 0 TOSLINE-S20 Active Star Coupler(ASC25) Instruction Manual REQUIREMENTS Keep this instruction manual where it can be easily referred to by users and those responsible for the equipment.
More informationVersaMax IP Input Module
Module is used to accept digital input signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature Storage temperature Operating/storage humidity 60mm
More informationTerminal block 2 A 5 X 3. Specification
D Series Features Automatic communication speed recognition : Enables to recognize communication speed automatically when connecting with master Network Voltage monitoring : If PV is lower than SV, enables
More informationADI12-8(USB)GY. Features. Packing List. F&eIt Series Isolated Analog Input Module for USB ADI12-8(USB)GY 1. Ver.1.02
F&eIt Series Isolated Analog Input Module for USB ADI128(USB)GY This product is a USB2.0 compatible terminal module that extends the analog input function of USB port of PCs. This product features 8ch
More informationMODEL: R3-NL1. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.
MODEL: R-NL Remote I/O R Series LonWorks INTERFACE MODULE (analog I/O points, discrete I/O 8 points) 7. (.08) 0 (.) 09 (.9) mm (inch) MODEL: R NL [][] ORDERING INFORMATI Code number: R-NL-[][] Specify
More informationCarbon Monoxide Sensor - ModBus
Introduction The CO Sensor uses an electrochemical sensor to monitor CO level in a range of 0 to 500 ppm and communicates via an RS-485 network configured for ModBus protocol. Before Installation Read
More informationD2 RMSM/ T1K RSSS Remote I/O System
D2 RMSM/ 2 2 D2 RMSM/ Remote Master (D2-RMSM) Features RUN--Turns N when the module is operating correctly. Remote Master DIAG--Turns N when there is a hardware failure. I/--Turns N when the setup program
More informationR1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)
INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL RM-GH BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.
More information9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)
echnical data sheet EF24A- Communicative spring return actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx.
More informationR7D-RR8 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, 8 points MODEL. (DeviceNet)
INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, points (DeviceNet) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined
More informationFR-2057iT. 16-channel Sink Type Isolated Output Module With Isolated Communication line. User Manual
FR-2057iT 16-channel Sink Type Isolated Output Module With Isolated Communication line User Manual Warranty All products manufactured by ICP DAS are warranted against defective materials for a period of
More informationDAL4 REPEATER MODEL. (SIN-NET, M-Bus use) MODEL & SUFFIX CODE SELECTION DAL4 TRANSMISSION ORDERING INFORMATION RELATED PRODUCTS GENERAL SPECIFICATIONS
REPETER (SIN-NET, M-us use) MODEL DL MODEL & SUFFIX CODE SELECTION MODEL CLE & PORT TYPE : Twisted-pair cable, ports : Fiber optics (PCF), ports Twisted-pair cable, port 5 : Fiber optics (I-50 nm), port
More informationPositioning Modules (with Multi-channel Pulse Output)
User s Manual Positioning Modules (with Multi-channel Pulse Output) IM 34M06H55-04E Applicable Modules: Model Code Model Name F3YP22-0P Positioning Module (with Multi-channel Pulse Output) F3YP24-0P Positioning
More informationSAFETY PRECAUTIONS CAUTION WARNING CAUTION. Thank you for purchasing ig5a Series Profibus Communication Module
SAFETY PRECAUTIONS Thank you for purchasing ig5a Series Profibus Communication Module SAFETY PRECAUTIONS Always follow safety instructions to prevent accidents and potential hazards from occurring. Safety
More informationTOUCH SCREEN CONTROLLER for Air Conditioning Control System
INSTALLATION MANUAL TOUCH SCREEN CONTROLLER for Air Conditioning Control System Model: BMS-TP064ACE BMS-TP064PWE BMS-TP52ACE BMS-TP52PWE Thank you very much for purchasing the TOSHIBA Touch Screen Controller.
More informationUSER'S GUIDE FX-485ADP COMMUNICATION ADAPTER FX0N-485ADP COMMUNICATION ADAPTER
FX- COMMUNICATION ADAPTER FX0N- COMMUNICATION ADAPTER USER'S GUIDE JY992D53201C This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation
More informationTopic: The PLC link function of DVP series PLCs
Topic: The PLC link function of DVP series PLCs Applicable model Keyword DVP-EH3 series, DVP-SV2 series, DVP-ES2/EX2 series, DVP-SX2 series, DVP-SA2 series, DVP-SS2 series, DVP-SE series, DVP-10MC series,
More informationGeneral Specifications
1 General Specifications FA-M3 Software Packages GS 34M06N01-01E Contents SF630-MCW FA-M3 Programming Tool WideField3... 3 SF661-MCW FA-M3 ToolBox for Temperature Control and Monitoring
More informationMachine Controller MP920 Communications Module USER'S MANUAL
YASKAWA Machine Controller MP920 Communications Module USER'S MANUAL YASKAWA MANUAL NO. SIEZ-C887-2.6B Copyright 1999 YASKAWA ELECTRIC CORPORATION All rights reserved. No part of this publication may be
More informationPackage Contents. GP Options (Made by Digital)
When connecting the power cord terminals to the GP, be sure the cord has first been unplugged from the power outlet to prevent the possibility of an electric shock. With the exception of changing the GP's
More informationCommunication & Networking
MicroSmart Master Module Capable of Connecting 62 Slaves Compliance with Ver. 2.1 specifi cations Digital and analog slaves can be connected. Configuration and slave monitoring can be done using LED indicators
More information205 CPU NETWORK ADAPTER F2-UNICON
205 CPU NEWORK ADAPER F2-UNICON Network Adapter he F2-UNICON Network Adapter is used to place Automationdirect.com DL205 CPUs (except D2-230 and D2-250) on a RS-422 or RS-485 multi-drop network. he Network
More informationNPN/PNP DISCRETE HIGH SPEED INPUT & NPN TRANSISTOR OUTPUT MODULE
R7K4JML-E-DAFC64A INSTRUCTION MANUAL NPN/PNP DISCRETE HIGH SPEED INPUT & NPN TRANSISTOR OUTPUT MODULE ( 2 points each, tension clamp terminal block, MECHATROLINK-III use ) MODEL R7K4JML-E-DAFC64A BEFORE
More informationSECTION 10 Analog Input/Output Option Board
SECTION 10 Input/Output Option Board This section describes how to use Input/Output Option Board. 10-1 General Specifications.......................................... 506 10-2 Part Names...................................................
More informationAD-8923-CC. Remote Controller (CC-Link) INSTRUCTION MANUAL 1WMPD B
AD-8923-CC Remote Controller (CC-Link) INSTRUCTION MANUAL 1WMPD4002124B 2013 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated
More informationVARMECA. Data communication systems. Réf GB / a
VARMECA Data communication systems Réf. 3427 GB - 2.33 / a - 07.01 The communication maestro A new networking solution VARMECA motors and geared motors, with integrated frequency inverter, offer a very
More informationASTAT XB/XBm Remote Operator
ASTAT XB/XBm Remote Operator User Manual 1 Introduction 1.1 Important User Information Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery
More informationWindows 8 / 7 CONTENTS. USB to RS-485 Converter. Part Number: USB FEATURES. 2 SPECIFICATIONS. 2 CONNECTIONS.. 3
CONTENTS USB to RS-485 Converter Part Number: USB-485-1 INTRODUCTION 2 FEATURES. 2 SPECIFICATIONS. 2 PIN ASSIGNMENT 2 CONNECTIONS.. 3 DRIVER INSTALLATION QUICK GUIDE.. 3 DRIVER INSTALLATION EXAMPLES..
More informationATV320U04N4C variable speed drive ATV kW V - 3 phase - compact
Characteristics variable speed drive ATV320-0.37kW - 380...500V - 3 phase - compact Main Range of product Product or component type Product specific application Device short name Format of the drive Product
More informationHan-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu
Contents Page Features... 19.02 Data interfaces... 19.03 Overview... 19.04 Cu... 19.06 F.O.... 19.08 Quintax 3 A... 19.10 RJ45 C... 19.12 USB / FireWire... 19.14 Han 4 A SC... 19.16 Hoods/Housings... 19.18
More informationAbout the Manual. ST-3400 Series Installation Guide. Package Contents
ST-3400 Series Installation Guide Caution Be sure to read the Warning/Caution Information on the attached sheet before using the product. Package Contents About the Manual For the detailed information
More informationSerial Data DIN Fiber Link System
USER GUIDE RLH Industries, Inc. The leader in rugged fiber optic technology. U-120 2017A-0420 DIN Fiber Link System COMPACT, RUGGED & TEMPERATURE HARDENED Introduction The DIN Fiber Link system transports
More informationPC104P-24DSI Channel 24-Bit Delta-Sigma PC104-Plus Analog Input Board
PC104P-24DSI12 12-Channel 24-Bit Delta-Sigma PC104-Plus Analog Input Board With 200 KSPS Sample Rate per Channel and Optional Low-Power Configuration Available also in PCI, cpci and PMC form factors as:
More informationTABLE OF CONTENTS. Communication Functions
TABLE OF CONTENTS Chapter 1: Chapter 2: Chapter 3: Chapter 4: General Features....................................................... 1-1 Functions......................................................
More informationUSER S MANUAL Power Supply for Backplane Vdc
USER S MANUAL Power Supply for Backplane 20-30 Vdc D F 5 6 M E smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is available on our
More informationDo-more H2 Series PLC System Specifications
Do-more H2 Series PLC System Specifications General Specifications General Specifications Operating Temperature 32 F to 131 F (0 C to 55 C) Storage Temperature 4 F to 158 F ( 20 C to 70 C) Ambient Humidity
More informationUser s Manual Positioning Module (with MECHATROLINK-II Interface)
User s Manual Positioning Module (with MECHATROLINK-II Interface) IM 34M6H60-02E Applicable Modules: Model Code Model Name F3NC96-0N Positioning Module (with MECHATROLINK-II Support) Yokogawa Electric
More informationNJ-Series Power Supply Unit NJ-PA/PD
NJ-Series Power Supply Unit CSM_NJ-PA_PD_DS_E_1_2 Powerful power supply unit to supply stable power to the NJ-series controller. Stable power supply is available from the NJ-series CPU Unit to each I/O