Hardware Owner s Manual

Size: px
Start display at page:

Download "Hardware Owner s Manual"

Transcription

1 Dell PowerEdge C1100 Systems Hardware Owner s Manual Regulatory Model CS24-TY

2 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Information in this document is subject to change without notice Dell Inc. All rights reserved. Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden. Trademarks used in this text: Dell, the DELL logo, and PowerEdge are trademarks of Dell Inc.; Intel and SpeedStep are registered trademarks of Intel Corporation in the U.S. and other countries; Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own. Regulatory Model CS24-TY December 2009 Rev. A00

3 Contents 1 About Your System Accessing System Features During Startup Front-Panel Features and Indicators Hard-Drive Indicator Patterns Back-Panel Features and Indicators NIC Indicator Codes Power and System Board Indicator Codes POST Error Codes Beep Codes Post Beep Codes Other Information You May Need Using the System Setup Program Start Menu System Setup Options at Boot Console Redirection Main Menu Main Screen AMIBIOS Settings Contents 3

4 Processor Settings System Memory Settings Advanced Menu Processor Configuration Memory Configuration IDE Configuration Super IO Configuration USB Configuration PCI Configuration Boot Menu Boot Settings Configuration Server Menu BMC LAN Configuration Remote Access Configuration Security Menu Exit Menu Installing System Components Safety Instructions Recommended Tools Inside the System Hard Drives Removing a Hard-Drive Blank Installing a Hard-Drive Blank Removing a Hard Drive From a Hard-Drive Carrier Contents

5 Installing a Hard Drive Into a Hard-Drive Carrier Removing a Hard-Drive Carrier Installing a Hard-Drive Carrier Opening and Closing the System Opening the System Closing the System Cooling Shroud Removing the Cooling Shroud Installing the Cooling Shroud Heat Sinks Removing the Heat Sink Installing the Heat Sink Processor Removing the Processor Installing the Processor System Memory General Memory Module Installation Guidelines Mode-Specific Guidelines Supported Memory Configuration Removing Memory Modules Installing Memory Modules Expansion-Card Riser and Expansion Card Removing the Expansion-Card Riser Installing the Expansion-Card Riser Removing the Expansion Card Installing the Expansion Card RAID Battery (Optional) Contents 5

6 Removing a RAID Battery Installing a RAID Battery Integrated Storage Controller Cards Removing the Integrated Storage Controller Card Installing the Integrated Storage Controller Card Mezzanine Card (10 GbE LAN) Removing the Mezzanine Card (10 GbE LAN) Installing the Mezzanine Card (10 GbE LAN) Power Supplies Removing the Non-Redundant Power Supply Installing the Non-Redundant Power Supply Removing the Redundant Power Supply Installing the Redundant Power Supply Power Distribution Board Removing the Power Distribution Board Installing the Power Distribution Board Cooling Fans Removing a Cooling Fan Assembly Installing the Cooling Fan Assembly Expander Board Removing the Expander Board Installing the Expander Board Backplane Removing the Backplane Installing the Backplane Contents

7 Control Panel (Optional) Removing the Control Panel Installing the Control Panel Control Panel Assembly (Optional) Removing the Control Panel Assembly Installing the Control Panel Assembly System Battery Removing the System Battery Installing the System Battery System Board Removing the System Board Installing the System Board Troubleshooting Your System Safety First For You and Your System Installation Problems Troubleshooting System Startup Failure Troubleshooting External Connections Troubleshooting the Video Subsystem Troubleshooting a USB Device Troubleshooting a Serial I/O Device Troubleshooting a NIC Troubleshooting a Wet System Troubleshooting a Damaged System Contents 7

8 Troubleshooting the System Battery Troubleshooting Power Supplies Troubleshooting System Cooling Problems Troubleshooting a Fan Troubleshooting System Memory Troubleshooting a Hard Drive Troubleshooting a Storage Controller Troubleshooting Expansion Cards Troubleshooting Processors IRQ Assignment Conflicts Troubleshooting Changes in BIOS Settings Collecting System Event Log for Investigation Jumpers and Connectors System Board Connectors Jumper Settings System Configuration Jumper Settings Backplane Jumper Settings Backplane Connectors Inch Hard Drives Inch Hard Drives Power Distribution Board Contents

9 6 Getting Help Contacting Dell Glossary Index Contents 9

10 10 Contents

11 About Your System Accessing System Features During Startup The following keystrokes provide access to system features during startup. Keystroke Description <F2> Enters the System Setup program. See "Start Menu" on page 33. <F11> Enters the BIOS Boot Manager. See "System Setup Options at Boot" on page 34. <F12> Starts Preboot execution Environment (PXE) boot. <Ctrl><C> Enters the SAS Configuration Utility. For more information, see the SAS adapter documentation. <Ctrl><R> Enters the RAID configuration utility. For more information, see the documentation for your SAS RAID card. <Ctrl><S> Enters the utility to configure NIC settings for PXE boot. For more information, see the documentation for your integrated NIC. About Your System 11

12 Front-Panel Features and Indicators Figure 1-1. Front-Panel Features 3.5-Inch Hard-Drive System Item Indicator, Button, or Connector Icon Description 1 Reset button Restarts the system while the system is powered on. 2 Service LED Lights when the BMC port is on and blinks when there is traffic on the BMC port. 3 Ethernet connectors 1 and 2 4 Hard drive activity LED Lights green when a connection is made to the NIC port, blinks when there is traffic on the NIC port. Lights when the hard drives are active. 5 Fault LED Displays status/errors and is controlled by BMC. 12 About Your System

13 Item Indicator, Button, or Connector 6 System identification indicator/button 7 Power-on indicator/power button Icon Description The system identification button can be used to locate a particular system and system board within a rack. When the button is pushed, the blue system status indicators on the front and the back blink until the button is pushed again. The power-on indicator lights when the system power is on. The power button controls the DC power supply output to the system. NOTE: When powering on the system, the video monitor can take from several seconds to over 2 minutes to display an image, depending on the amount of memory installed in the system. NOTE: On ACPI-compliant operating systems, turning off the system using the power button causes the system to perform a graceful shutdown before power to the system is turned off. NOTE: To force an ungraceful shutdown, press and hold the power button for 5 seconds. 8 USB connectors (2) Connects USB devices to the system. The ports are USB 2.0-compliant. 9 Hard drives Up to four hot-swappable 3.5-inch hard drives. About Your System 13

14 Figure 1-2. Front-Panel Features 2.5-Inch Hard-Drive Systems Item Indicator, Button, or Connector Icon Description 1 Hard drives Up to ten hot-swappable 2.5-inch hard drives. 2 Ethernet connectors 1 and 2 3 System identification indicator/button Lights green when a connection is made to the NIC port, blinks when there is traffic on the NIC port. The system identification button can be used to locate a particular system and system board within a rack. When the button is pushed, the blue system status indicators on the front and the back blink until the button is pushed again. 14 About Your System

15 Item Indicator, Button, or Connector 4 Power-on indicator/power button Icon Description The power-on indicator lights when the system power is on. The power button controls the DC power supply output to the system. NOTE: When powering on the system, the video monitor can take from several seconds to over 2 minutes to display an image, depending on the amount of memory installed in the system. NOTE: On ACPI-compliant operating systems, turning off the system using the power button causes the system to perform a graceful shutdown before power to the system is turned off. NOTE: To force an ungraceful shutdown, press and hold the power button for 5 seconds. 5 Fault LED Displays status/errors and is controlled by BMC. About Your System 15

16 Hard-Drive Indicator Patterns Figure 1-3. Hard-Drive Indicators inch hard-drive carrier inch hard-drive carrier 1 hard-drive activity indicator (green) 2 hard-drive status indicator (green and amber) Table 1-1. Hard Drive Indicators On-Board SATA Ports Drive-Activity Indicator/Drive-Status Indicator Off/Off Steady green/off Steady green/steady green Steady green/blinks green Condition No drive No access Drive online Drive is present or in idle stage Table 1-2. Hard Drive Indicators SAS/SATA Add-on Cards Drive-Activity Indicator/Drive-Status Indicator Off/Off Steady green/off Steady green/steady green Condition No drive No access Drive online 16 About Your System

17 Table 1-2. Hard Drive Indicators SAS/SATA Add-on Cards (continued) Drive-Activity Indicator/Drive-Status Indicator Steady green/blinks green Steady amber/off Steady amber/steady green Condition Drive is present or in idle stage Drive failed Drive rebuilding Back-Panel Features and Indicators Figure 1-4. Back-Panel Features Item Indicator, Button, or Connector Icon Description 1 Power supply 650 W 2 Power LED Lights green when the power supply is functioning properly. 3 Fault LED Displays status/errors and is controlled by BMC. 4 System identification indicator Both the systems management software and the identification buttons located on the front can cause the indicator to flash blue to identify a particular system and system board. Lights amber when the system needs attention due to a problem. 5 Serial connector Connects a serial device to the system. 6 Video connector Connects a VGA display to the system. About Your System 17

18 Item Indicator, Button, or Connector Icon Description 7 USB connectors (2) Connects USB devices to the system. The ports are USB 2.0-compliant. 8 KVM over IP Port Dedicated management port. 9 Ethernet connectors (2) Embedded 10/100/1000 NIC connector. 10 Mezzanine-card cover Remove this cover before installing mezzanine card. NIC Indicator Codes Figure 1-5. NIC Indicators link indicator 2 activity indicator Table 1-3. NIC Speed Indicator Codes NIC Speed Indicator Steady amber Blinks amber Steady green Blinks green Green off Condition Link at 1 Gbps Identify port with 1 Gbps connection Link at 100 Mbps Identify port with 10 Mbps or 100 Mbps connection Link at 10 Mbps 18 About Your System

19 Table 1-4. NIC Indicator Codes BMC NIC Indicator Steady green Blinks green Green off Condition Link LAN/No access Accessing LAN Idle Table 1-5. NIC Speed Indicator Codes (KVM Over IP Port) NIC Speed Indicator Steady green Green off Condition Link at 100 Mbps Link at 10 Mbps Power and System Board Indicator Codes The LEDs on the system front and back panel display error codes during system startup. Systems with 2.5-inch or 3.5-inch hard drives share the same LEDs on the front and back panel. Table 1-6 lists the status associated with the error codes. Table 1-6. Power and System Board Indicator Codes Power-On Indicator Steady green, Amber off Green off, Blinks amber Green, Blinks amber Condition Power On (S0/S1) BMC critical condition event in power off mode (S4/S5) BMC critical condition event in power off mode (S0/S1) About Your System 19

20 Table 1-7. System Identification Indicators System Identification Indicator Steady blue Blinks blue blinking Blue off Condition IPMI using chassis identify command on or ID button press identification on. Only IPMI using chassis identify command blink on. IPMI using chassis identify command off or ID button press identification off. Table 1-8. Power Indicator Codes Power Indicator Steady green Steady yellow Yellow off Condition Power supply is on (AC OK/DC OK) or in standby mode ( VAC) Power supply faulty (UVP/OVP/OCP/SCP/OTP/Fan Fault) Power supply is off or AC input voltage is out of normal operating range (90 VAC 264 VAC) Table 1-9. Fault Indicator Codes Fault Indicator Amber blinking Amber off Condition System failure or Non-critical failure: non-critical fan, voltage, temperature state, or CPU thermal trip. No system failure or Off 20 About Your System

21 POST Error Codes Code Log in BMC Error Message Corrective Action 0000 Yes Timer Error Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page Yes CMOS Battery Low See "Troubleshooting the System Battery" on page Yes CMOS Settings Wrong 0005 Yes CMOS Checksum Bad 000B Yes CMOS memory size Wrong Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 119. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 119. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page C Yes RAM R/W test failed Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page E Yes A: Driver Error See "Troubleshooting a Hard Drive" on page F Yes B: Driver Error See "Troubleshooting a Hard Drive" on page Yes CMOS Date/Time Not Set Remove AC power to the system for 10 seconds and restart the system. See "Troubleshooting the System Battery" on page 100. If the problem persists, see "Getting Help" on page 119. About Your System 21

22 Code Log in BMC Error Message Corrective Action 0040 Yes Refresh timer test failed 0041 Yes Display memory test failed 0042 Yes CMOS Display Type Wrong 0044 Yes DMA Controller Error Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 119. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 119. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 119. See "Troubleshooting System Memory" on page 103. If the problem persists, see "Getting Help" on page Yes DMA-1 Error See "Troubleshooting System Memory" on page 103. If the problem persists, see "Getting Help" on page Yes DMA-2 Error See "Troubleshooting System Memory" on page 103. If the problem persists, see "Getting Help" on page Yes Unknown BIOS error Yes Password check failed Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 119. Reset password. See "Jumper Settings" on page 112. If the problem persists, see "Getting Help" on page About Your System

23 Code Log in BMC Error Message Corrective Action 0049 Yes Unknown BIOS error. 004A Yes Unknown BIOS error. 004B Yes Unknown BIOS error. 005E Yes Password check failed 005D Yes S.M.A.R.T. Command Failed S.M.A.R.T. Status BAD, Backup and Replace 0060 Yes Primary Master Hard Disk Error 0061 Yes Primary Salve Hard Disk Error 0062 Yes Secondary Master Hard Disk Error 0063 Yes Secondary Salve Hard Disk Error 0080 Yes Primary Master Drive - ATAPI Incompatible 0081 Yes Primary Salve Drive - ATAPI Incompatible Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 119. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 119. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 119. Reset password. See "Jumper Settings" on page 112. If the problem persists, see "Getting Help" on page 119. See "Getting Help" on page 119. See "Troubleshooting a Hard Drive" on page 105. See "Troubleshooting a Hard Drive" on page 105. See "Troubleshooting a Hard Drive" on page 105. See "Troubleshooting a Hard Drive" on page 105. See "Troubleshooting a Hard Drive" on page 105. See "Troubleshooting a Hard Drive" on page 105. About Your System 23

24 Code Log in BMC Error Message Corrective Action 0082 Yes Secondary Master Drive - ATAPI Incompatible 0083 Yes Secondary Slave Drive - ATAPI Incompatible 0101 Yes Warning! This system board does not support the power requirements of the installed processor. The processor will be run at a reduced frequency, which will impact system performance Yes Error! The CPU Core to Bus ratio or VID configuration has failed! Please enter BIOS Setup and re-config it Yes Thermal Failure detected by PROCHOT# Yes Thermal Failure detected by PROCHOT#. See "Troubleshooting a Hard Drive" on page 105. See "Troubleshooting a Hard Drive" on page 105. Ensure that your processors match and conform to the type described in the processor technical specifications outlined in your system s Getting Started Guide. See "Troubleshooting Processors" on page 108. The message is displayed on the screen, an error is logged to the SEL, and user input is required to continue. The user can take immediate corrective action or choose to continue booting. Ensure that the processor heat sinks are properly installed. See "Troubleshooting Processors" on page 108 and "Troubleshooting System Cooling Problems" on page 102. Ensure that the processor heat sinks are properly installed. See "Troubleshooting Processors" on page 108 and "Troubleshooting System Cooling Problems" on page About Your System

25 Code Log in BMC Error Message Corrective Action 0122 Yes Thermal Failure detected by PROCHOT# Yes Thermal Failure detected by PROCHOT# Yes Thermal Failure detected by PROCHOT# Yes Thermal Failure detected by PROCHOT# Yes Thermal Failure detected by PROCHOT# Yes Thermal Failure detected by PROCHOT# Yes Processor failed BIST Ensure that the processor heat sinks are properly installed. See "Troubleshooting Processors" on page 108 and "Troubleshooting System Cooling Problems" on page 102. Ensure that the processor heat sinks are properly installed. See "Troubleshooting Processors" on page 108 and "Troubleshooting System Cooling Problems" on page 102. Ensure that the processor heat sinks are properly installed. See "Troubleshooting Processors" on page 108 and "Troubleshooting System Cooling Problems" on page 102. Ensure that the processor heat sinks are properly installed. See "Troubleshooting Processors" on page 108 and "Troubleshooting System Cooling Problems" on page 102. Ensure that the processor heat sinks are properly installed. See "Troubleshooting Processors" on page 108 and "Troubleshooting System Cooling Problems" on page 102. Ensure that the processor heat sinks are properly installed. See "Troubleshooting Processors" on page 108 and "Troubleshooting System Cooling Problems" on page 102. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 119. About Your System 25

26 Code Log in BMC Error Message Corrective Action 0151 Yes Processor failed BIST 0152 Yes Processor failed BIST 0153 Yes Processor failed BIST 0154 Yes Processor failed BIST 0155 Yes Processor failed BIST 0156 Yes Processor failed BIST 0157 Yes Processor failed BIST 0160 Yes Processor missing microcode Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 119. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 119. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 119. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 119. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 119. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 119. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 119. A BIOS update is required. If the problem persists, see "Getting Help" on page About Your System

27 Code Log in BMC Error Message Corrective Action 0161 Yes Processor missing microcode 0162 Yes Processor missing microcode 0163 Yes Processor missing microcode 0164 Yes Processor missing microcode 0165 Yes Processor missing microcode 0166 Yes Processor missing microcode 0167 Yes Processor missing microcode 0180 Yes BIOS does not support current stepping 0181 Yes BIOS does not support current stepping A BIOS update is required. If the problem persists, see "Getting Help" on page 119. A BIOS update is required. If the problem persists, see "Getting Help" on page 119. A BIOS update is required. If the problem persists, see "Getting Help" on page 119. A BIOS update is required. If the problem persists, see "Getting Help" on page 119. A BIOS update is required. If the problem persists, see "Getting Help" on page 119. A BIOS update is required. If the problem persists, see "Getting Help" on page 119. A BIOS update is required. If the problem persists, see "Getting Help" on page 119. Ensure that your processors match and conform to the type described in the processor technical specifications outlined in your system s Getting Started Guide. Ensure that your processors match and conform to the type described in the processor technical specifications outlined in your system s Getting Started Guide. About Your System 27

28 Code Log in BMC Error Message Corrective Action 0182 Yes BIOS does not support current stepping 0183 Yes BIOS does not support current stepping 0184 Yes BIOS does not support current stepping 0185 Yes BIOS does not support current stepping 0186 Yes BIOS does not support current stepping 0187 Yes BIOS does not support current stepping 0194 Yes CPUID, Processor family are different Ensure that your processors match and conform to the type described in the processor technical specifications outlined in your system s Getting Started Guide. Ensure that your processors match and conform to the type described in the processor technical specifications outlined in your system s Getting Started Guide. Ensure that your processors match and conform to the type described in the processor technical specifications outlined in your system s Getting Started Guide. Ensure that your processors match and conform to the type described in the processor technical specifications outlined in your system s Getting Started Guide. Ensure that your processors match and conform to the type described in the processor technical specifications outlined in your system s Getting Started Guide. Ensure that your processors match and conform to the type described in the processor technical specifications outlined in your system s Getting Started Guide. Ensure that your processors match and conform to the type described in the processor technical specifications outlined in your system s Getting Started Guide. 28 About Your System

29 Code Log in BMC Error Message Corrective Action 0196 Yes CPUID, Processor Model are different 0193 Yes CPUID, Processor stepping are different 0192 Yes L2 cache size mismatch 0197 Yes Processor speeds mismatched Ensure that your processors match and conform to the type described in the processor technical specifications outlined in your system s Getting Started Guide. Ensure that your processors match and conform to the type described in the processor technical specifications outlined in your system s Getting Started Guide. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 119. Ensure that your processors match and conform to the type described in the processor technical specifications outlined in your system s Getting Started Guide Yes Processor Mismatch Ensure that your processors match and conform to the type described in the processor technical specifications outlined in your system s Getting Started Guide Yes AHCI Port0 HDD Error 0401 Yes AHCI Port1 HDD Error 0402 Yes AHCI Port2 HDD Error 0403 Yes AHCI Port3 HDD Error 0404 Yes AHCI Port4 HDD Error See "Troubleshooting a Hard Drive" on page 105. See "Troubleshooting a Hard Drive" on page 105. See "Troubleshooting a Hard Drive" on page 105. See "Troubleshooting a Hard Drive" on page 105. See "Troubleshooting a Hard Drive" on page 105. About Your System 29

30 Code Log in BMC Error Message Corrective Action 0405 Yes AHCI Port5 HDD Error 5120 Yes CMOS cleared by jumper 5121 Yes Password cleared by jumper 8101 Yes Warning! USB Host Controller not found at the specified address!!! 8102 Yes Error! USB device failed to initialize!!! 8103 Yes Warning! Unsupported UBS device found and disabled!!! 8104 Yes Warning! Port 60h/64h emulation is not supported by this USB Host Controller!!! 8105 Yes Warning! EHCI controller disabled. It requires 64-bit data support in the BIOS. See "Troubleshooting a Hard Drive" on page 105. Reset password. See "Jumper Settings" on page 112. If the problem persists, see "Getting Help" on page 119. Reset password. See "Jumper Settings" on page 112. If the problem persists, see "Getting Help" on page 119. See "Troubleshooting a USB Device" on page 96. If the problem persists, see "Getting Help" on page 119. See "Troubleshooting a USB Device" on page 96. If the problem persists, see "Getting Help" on page 119. See "Troubleshooting a USB Device" on page 96. If the problem persists, see "Getting Help" on page 119. See "Troubleshooting a USB Device" on page 96. If the problem persists, see "Getting Help" on page 119. See "Troubleshooting a USB Device" on page 96. If the problem persists, see "Getting Help" on page About Your System

31 Code Log in BMC Error Message Corrective Action 8301 Yes Not enough space in Runtime area! SMBIOS data will not be available Yes Not enough space in Runtime area! SMBIOS data will not be available Yes Error: BMC Not Responding 8701 Yes Insufficient Runtime space for MPS data. System may operate in PCI or Non-MPS mode. Beep Codes See "Troubleshooting System Memory" on page 103. If the problem persists, see "Getting Help" on page 119. See "Troubleshooting System Memory" on page 103. If the problem persists, see "Getting Help" on page 119. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 119. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 119. The following table describes the beep codes that are used in boot block: Number of Beeps Description 1 No media 2 Boot-block bios file absent 3 Insert next diskette in A: 4 Flash program successful 5 Read file error 7 No flash present 8 Floppy controller error 10 Flash erase error 11 Flash program error About Your System 31

32 Number of Beeps Description 12 Wrong bios file size 13 ROM image mismatch 14 (1 long beep BIOS recovery by jumper after 4 beeps) Post Beep Codes Number of Beeps Description 1 Refresh timer error 3 Base 64 K memory failure gate A20 failure 8 Display memory read/write failure 2 Exception interrupt shutdown 3 No main memory Other Information You May Need WARNING: See the safety and regulatory information that shipped with your system. Warranty information may be included within this document or as a separate document. The Getting Started Guide provides an overview of rack installation, system features, setting up your system, and technical specifications. NOTE: Always check for updates on support.dell.com/manuals and read the updates first because they often supersede information in other documents. 32 About Your System

33 Using the System Setup Program Start Menu The system employs the latest AMI Core BIOS, which is stored in Flash memory. The Flash memory supports the Plug and Play specification, and contains a BIOS Setup program, the Power-On Self-Test (POST) routine, and the PCI auto-configuration utility. This system board supports system BIOS shadowing, enabling the BIOS to execute from 64-bit onboard write-protected DRAM. Configure items such as: Hard drives, diskette drives, and peripherals Password protection from unauthorized use Power management features This Setup utility should be executed under the following conditions: When changing the system configuration When a configuration error is detected by the system and you are prompted to make changes to the Setup utility When redefining the communication ports to prevent any conflicts When changing the password or making other changes to the security setup NOTE: Only items in brackets [ ] can be modified. Items that are not in brackets are display only. Using the System Setup Program 33

34 System Setup Options at Boot You can initiate Setup by pressing <F2> during POST. Console Redirection The console redirection allows a remote user to diagnose and fix problems on a system, which has not successfully booted the operating system. The centerpiece of the console redirection is the BIOS Console. The BIOS Console is a Flash ROM-resident utility that redirects input and output over a serial or modem connection. The BIOS supports console redirection to a serial port. If serial port based headless system support is provided by the system, the system must provide support for redirection of all BIOS driven console I/O to the serial port. The driver for the serial console must be capable of supporting the functionality documented in the ANSI Terminal Definition. 34 Using the System Setup Program

35 Main Menu The main menu displays information about your system board and BIOS. Main Screen Figure 2-1. System Setup Program Main Screen NOTE: The options for the System Setup program change based on the system configuration. NOTE: The System Setup program defaults are listed under their respective options in the following sections, where applicable. AMIBIOS Settings Option Version Build Date ID Description Displays the BIOS version. Check this version number when updating BIOS from the manufacturer. Displays the date the BIOS was created. Displays the BIOS ID. Using the System Setup Program 35

36 Processor Settings Option Type Speed Count Description Displays the type of processor installed on the system board. Displays the maximum speed of the processor. Displays the number of installed processors. System Memory Settings Option Size System Time System Date Description Displays how much memory (DRAM) is installed on the system board. Scroll to adjust the time. Scroll to adjust the date. Advanced Menu This option displays a table of items that defines advanced information about your system. WARNING: Making incorrect settings to items on these pages may cause the system to malfunction. Unless you have the experience in adjusting these items, it is recommended that you leave these settings at the default values. If making settings to items on these pages causes your system to malfunction or prevents the system from booting, open BIOS and choose "Load Optimal Defaults" in the Exit menu to boot up normally. Processor Configuration Option Hardware Prefetcher (Enabled default) Adjacent Cache Line Prefetch (Enabled default) Description Enables you to control the Hardware Prefetcher feature. Enables you in order to control the Adjacent Cache Line Prefetch feature. 36 Using the System Setup Program

37 Option Max CPUID Value Limit (Disabled default) Intel(R) Virtualization Tech (Enabled default) Execute-Disable Bit Capability (Enabled default) Active Processor Cores (All default) Intel(R) HT Technology (Enabled default) Intel(R) SpeedStep(TM) tech (Enabled for OS default) Intel(R) TurboMode tech (Enabled default) Intel(R) C-STATE tech (Enabled default) C3 State (Disabled default) C6 State (Enabled default) NUMA Support (Disabled default) Description Enable this option to limit the maximum CPUID input value to 03h when queried, even if the processor supports a higher CPUID input value. NOTE: This feature is disabled for Windows XP Intel processors from Pentium Pro onwards, except Intel Pentium 4, that have a maximum CPUID input value of only 02h or 03h. Enable this option when the processor supports VT. A full reset is needed to change its state. When Disabled, forces the XD feature flag to always return 0. Sets the number of cores to enable in each processor package. When Disabled, allows only one thread per enabled core. Allows the clock speed of the processor to be dynamically changed by software. Allows processor cores to run faster than marked frequency in specific condition. CState: CPU idle is set to C1/C2/C3/C6/C7. Displays the size of CPU L2. Displays the size of CPU L3. When enabled, executes software for NUMA aware OS. When disabled, it allows better memory access performance for non-numa OS. Using the System Setup Program 37

38 Memory Configuration Option Current Memory Frequency (1066 MHz default) Memory Turbo Mode (Disabled default) Memory Frequency (Auto default) Memory Mode (Independent default) Throttling - Closed Loop (Enabled default) Throttling - Open Loop (Enabled default) Description Displays the current memory frequency Displays the memory turbo mode. Forces a DDR3 frequency slower than the common tck detected via SPD. Selects the memory mode. Enables BIOS to program Closed Loop throttling for memory components. Enables BIOS to program Open Loop throttling for memory components. IDE Configuration Option SATA#1 Configuration (Enhanced default) Configure SATA as (IDE default) Hard Disk Write Protect (Disabled default) IDE Detect Time Out (Sec) Description Configures the SATA#1. Configures the SATA. IDE AHCI RAID Enables or disables device write protection. This is effective only if the device is accessed through BIOS. Selects the time out value for detecting ATA/ATAPI device(s). 38 Using the System Setup Program

39 Super IO Configuration Option Serial Port1 Address (3F8/IRQ4 default) Serial Port2 Address (3F8/IRQ4 default) Description Assigns the I/O address and IRQ for the first onboard serial port. Assigns the I/O address and IRQ for the second onboard serial port. USB Configuration Option USB Devices Enabled Legacy USB Support (Auto default) USB 2.0 Controller USB Mass Storage Reset Delay (20 Sec default) Device# Emulation Type (Auto default) Description Displays USB devices currently detected. Enables support for legacy USB devices. Select Auto to disable legacy support if no USB devices are connected. Configures the USB 2.0 controller in HiSpeed (480 Mbps) or FullSpeed (12 Mbps). Displays the number of seconds that the POST waits for the USB mass storage device after the start unit command is issued. USB device model name. If the type is set to Auto, USB devices which are less than 530 MB are emulated as floppies and the others are emulated as hard drives. Forced FDD option can be used to force a formatted hard drive to boot as FDD (e.g. ZIP drive). PCI Configuration Option NIC1 KAWELA (Enable with PXE default) NIC2 KAWELA (Enable with PXE default) Description Enables or disables onboard NIC1 PXE option ROM. Enables or disables onboard NIC2 PXE option ROM. Using the System Setup Program 39

40 Option PCI-E SLOT Option Rom (Enabled default) PCI-E Connector Option Rom (Enabled default) NIC1 Mac Address NIC2 Mac Address Current QPI Frequency QPI Link Speed (Full-Speed default) QPI Frequency (Auto default) QPI L0s and L1 (Enabled default) Crystal Beach / DMA (Disabled default) Intel VT-d (Disabled default) SR-IOV Supported (Disabled default) Active State Power Management (Disabled default) ME Support (Enabled default) Port 2 Width Description Enables or disables add-on card option rom. Enables or disables board to board PCI-E connector option rom. Displays the NIC1 MAC address. Displays the NIC2 MAC address. Enables or disables the QPI frequency. Enables or disables the QPI link speed. Enables or disables the QPI frequency. Enables or disables the QPI L0s and L1. Enables or disables the Crystal Beach / DMA configuration. Enables or disables the Intel Virtualization Technology for Directed I/O. Enables or disables SR-IOV support. Enables the individual serial Links in a PCI Express fabric to be incrementally reduced as a Link becomes less active. Enables the Management Engine (ME) to allow for the use of Intel AMT. Select the Port 2 Width. Settings: X2 or X2/X4. 40 Using the System Setup Program

41 Boot Menu Option Boot Settings Configuration Boot Device Priority Hard Disk Drives CD/DVD Drives Network Device Description Configures the settings during system boots. Specifies the boot device priority. Specifies the boot device priority sequence from the available hard drives. Specifies the boot device priority sequence from the available CD/DVD drives. Specifies the network device. Boot Settings Configuration Option Quick Boot (Enabled default) Quiet Boot (Disabled default) AddOn ROM Display Mode (Force BIOS default) Bootup Num-Lock (On default) Wait For 'F1' If Error (Disabled default) Hit 'F2' Message Display (Enabled default) Force PXE First (Enabled default) Description Enables you to allow BIOS to skip certain tests during the POST, which decreases boot up time. Enable or disable quiet boot. Disabled: displays normal POST messages. Enabled: displays OEM logo instead of POST messages. Enables you to display mode controlled by BIOS or addon ROM. Enables you to set the state of the keyboard keypad on boot. On: The keypad functions as a keypad. Off: The keypad functions as auxiliary cursor movement keys. Enables the system to prompt you to press F1 if an error occurs. This enables you to view the error. Enables the system to prompt you to press 'F2' to enter the BIOS Setup Utility. Enables forced network boot (PXE). Using the System Setup Program 41

42 Server Menu NOTE: Delay Time, Minimum time, and Maximum time are only shown in SETUP screen when AC Power Recovery Delay is set to User define. The selection of Restore on AC Power Loss setup to Power-on or Last State takes 60 seconds for running BMC initialization after AC Power on. Option Status of BMC IPMI Specification Version BMC Firmware Version Set BMC LAN Configuration Remote Access Configuration Restore on AC Power Loss (Power Off default) Power Staggering AC Recovery (User Defined default) Power On Delay View BMC System Event Log Clear BMC System Event Log Event Logging (Enabled default) ECC Event Logging (Enabled default) PCI Error Logging (Enabled default) Description Displays the status of BMC. Displays the BMC supported IPMI version. Displays the firmware version of BMC. Input for Set LAN configuration command. Configures remote access. Restores the AC power setting. The options are Power Off, Power On and Last State. Selects the time of system power on after BMC initiates. Immediate: powers on directly after BMC initiates. Random: randomly selects time to power on. User define: allows the user to select the time. Displays the AC power recovery delay time. Displays all events in the BMC Event Log. Clears all events in BMC System Event Log. Enables or disables BIOS to record Event Logging. Enables or disables ECC Event Logging. Enable or disable PCI Error Logging. 42 Using the System Setup Program

43 Option QPI Error Logging (Enabled default) IOH Internal Error Logging (Enabled default) NMI on Error (Fatal default) Description Enable or disable IOH QPI 0/1 error. Enable or disable IOH Internal error logging. Enable to set the state of NMI on Error: Fatal: Fatal error issue NMI. Uncorrectable: Fatal and Uncorrectable errors issue NMI. Correctable: Issues NMI on all errors. BMC LAN Configuration Option Channel Number Channel Number Status (01 default) BMC LAN Port Configuration (Shared-NIC default) DHCP Enabled (Disabled default) IP Address Subnet Mask Gateway Address Current MAC Address in BMC Description Displays channel number of BMC. Displays channel number status of BMC. Select the BMC LAN Port Configuration type. Enables or disables the BMC get the LAN IP from a DHCP server. Enter an IP address in decimal in the form of XXX.XXX.XXX.XXX (XXX less than 256 and in decimal only). Enter a Subnet Mask in decimal in the form of XXX.XXX.XXX.XXX (XXX less than 256 and in decimal only). Enter Gateway Address in decimal in the form of XXX.XXX.XXX.XXX (XXX less than 256 and in decimal only). Displays the MAC address of BMC. Using the System Setup Program 43

44 Remote Access Configuration Option Remote Access (Enabled default) Serial Port Number (COM1 default) Current SOL Baud Rate Serial Port Mode ( ,n,1 default) Flow Control (None default) Redirection After BIOS POST (Enabled default) Terminal Type (ANSI default) Description Selects remote access type. Selects serial port for console redirection. Displays the current SOL Baud Rate. Selects serial port settings. The default value may change if SOL baud rate is fixed by customer request. Selects flow control for console redirection. Selects the settings for the redirection. Disabled: turns off the redirection after POST. Enabled: redirection is always active. Selects the target terminal type. NOTE: When Flow Control is set to Software, the Hyper Terminal on remote side is discontinued by pressing <Ctrl><S>. But the <Ctrl><S> is also the Setup Key Stroke for setting onboard NIC PXE Option ROM Configuration. Therefore, we suggest users change <Ctrl><S> to <Ctrl><B> in PXE OPROM Configuration in order to avoid that the Hyper Terminal on remote side is discontinued when pressing <Ctrl><S>. 44 Using the System Setup Program

45 Security Menu Option Description Supervisor Password Displays whether the supervisor password is installed or not. User Password Displays whether the user password is installed or not. Change Supervisor Password/ Change User Password Exit Menu Use this option to install, change or clear the password. If you select these items and press Enter, a dialog box appears and then you can enter a password. You can enter no more than six letters or numbers. Press Enter after you have typed in the password. A second dialog box asks you to retype the password for confirmation. Press Enter after you have retyped it correctly. The password is required at boot time, or when the user enters the Setup Utility. Option Save Changes and Exit Discard Changes and Exit Discard Changes Load Optimal Defaults Description Select to save any changes that you have made in the Setup utility and exit the Setup utility. Select to discard any changes that you have made in the Setup utility and exit the Setup utility. Select to discard any changes you have made without leaving the setup utility. Select to install optimal settings for all the items in the Setup utility. Using the System Setup Program 45

46 46 Using the System Setup Program

47 Installing System Components Safety Instructions WARNING: Working on systems that are still connected to a power supply can be extremely dangerous. CAUTION: System components and electronic circuit boards can be damaged by discharge of static electricity. CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product. To avoid injury to yourself or damage to your system, follow these guidelines: Always disconnect the system from the power outlet whenever you are working inside the system case. If possible, wear a grounded wrist strap when you are working inside the system case. Alternatively, discharge any static electricity by touching the bare metal chassis of the system case, or the bare metal body of any other grounded appliance. Hold electronic circuit boards by the edges only. Do not touch the components on the board unless it is necessary to do so. Do not flex or stress the circuit board. Leave all components inside the static-proof packaging until they are ready for installation. Recommended Tools Phillips screwdriver Flat-tipped screwdriver Installing System Components 47

48 Inside the System CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product. CAUTION: This system must be operated with the system cover installed to ensure proper cooling. NOTE: The illustration in this section shows a system with 3.5-inch hard drives. Figure 3-1. Inside the System SAS backplane 2 system cooling fans (6) 3 mezzanine card 4 storage controller card 5 cooling shroud 6 expansion-card riser 7 heat sink/processors (2) 8 memory modules (18) 9 power supply bay(s) 10 power distribution board 48 Installing System Components

49 Hard Drives CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product. CAUTION: Use only hard drives that have been tested and approved for use with the SAS/SATA backplane. CAUTION: When you remove or install the hard drive, take note of the drive carrier orientation before sliding it out. The carrier does not fit back into the bay if inserted incorrectly. Make sure that the hard drive is connected to the hard drive connector on the backplane CAUTION: When installing a hard-drive carrier, ensure that the adjacent drives are fully installed. Inserting a hard-drive carrier and attempting to lock its handle next to a partially installed carrier can damage the partially installed carrier's shield spring and make it unusable. CAUTION: To prevent data loss, ensure that your operating system supports hot-swap drive installation. See the documentation supplied with the operating system. Your system supports 3.5-inch or 2.5-inch (SAS or SATA) hard drives. The installation and removal procedures for the 3.5-inch hard drive and 2.5-inch hard drive are similar. The following is an example using the replacement procedure of 3.5-inch hard drive. Removing a Hard-Drive Blank CAUTION: To maintain proper system cooling, all empty hard-drive bays must have-drive blanks installed. Press the release button and slide the hard-drive blank out of the hard drive bay. See Figure 3-2. Installing System Components 49

Dell PowerEdge R620. Owner's Manual. Regulatory Model: E16S Series Regulatory Type: E16S001

Dell PowerEdge R620. Owner's Manual. Regulatory Model: E16S Series Regulatory Type: E16S001 Dell PowerEdge R620 Owner's Manual Regulatory Model: E16S Series Regulatory Type: E16S001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

Dell PowerEdge T110 Systems. Hardware Owner s Manual

Dell PowerEdge T110 Systems. Hardware Owner s Manual Dell PowerEdge T110 Systems Hardware Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates

More information

Dell PowerEdge R920 System Owner's Manual

Dell PowerEdge R920 System Owner's Manual Dell PowerEdge R920 System Owner's Manual Regulatory Model: E23S Series Regulatory Type: E23S001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use

More information

Dell PowerEdge R230 Owner's Manual

Dell PowerEdge R230 Owner's Manual Dell PowerEdge R230 Owner's Manual Regulatory Model: E33S Series Regulatory Type: E33S001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

Dell PowerEdge R230 Owner's Manual

Dell PowerEdge R230 Owner's Manual Dell PowerEdge R230 Owner's Manual Regulatory Model: E33S Series Regulatory Type: E33S001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

Hardware Owner s Manual

Hardware Owner s Manual Dell PowerEdge C8220X Hardware Owner s Manual Regulatory Model: B06B Regulatory Type: B06B001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of

More information

Dell XC720xd Owner's Manual

Dell XC720xd Owner's Manual Dell XC720xd Owner's Manual Regulatory Model: E14S Series Regulatory Type: E14S001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

Dell PowerEdge R710 Systems Hardware Owner s Manual

Dell PowerEdge R710 Systems Hardware Owner s Manual Dell PowerEdge R710 Systems Hardware Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates

More information

Dell PowerEdge T420 Systems Owner's Manual

Dell PowerEdge T420 Systems Owner's Manual Dell PowerEdge T420 Systems Owner's Manual Regulatory Model: E20S Series Regulatory Type: E20S001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use

More information

Dell PowerEdge R320 Systems Owner's Manual

Dell PowerEdge R320 Systems Owner's Manual Dell PowerEdge R320 Systems Owner's Manual Regulatory Model: E18S Series Regulatory Type: E18S001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use

More information

Installation and Troubleshooting Guide

Installation and Troubleshooting Guide 2 Processor/2U-N Systems Installation and Troubleshooting Guide Model EMS Notes, Notices, and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. NOTICE:

More information

Dell PowerEdge R300 Systems Hardware Owner s Manual

Dell PowerEdge R300 Systems Hardware Owner s Manual Dell PowerEdge R300 Systems Hardware Owner s Manual www.dell.com support.dell.com Notes, Notices, and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

Dell PowerEdge 6 Gbps SAS HBA and Internal Tape Adapter. User s Guide

Dell PowerEdge 6 Gbps SAS HBA and Internal Tape Adapter. User s Guide Dell PowerEdge 6 Gbps SAS HBA and Internal Tape Adapter User s Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION:

More information

Dell PowerEdge R330 Owner's Manual

Dell PowerEdge R330 Owner's Manual Dell PowerEdge R330 Owner's Manual Regulatory Model: E34S Series Regulatory Type: E34S001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

Dell PowerEdge R620 Owner's Manual

Dell PowerEdge R620 Owner's Manual Dell PowerEdge R620 Owner's Manual Regulatory Model: E16S Series Regulatory Type: E16S001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

Dell PowerEdge R430 Owner's Manual

Dell PowerEdge R430 Owner's Manual Dell PowerEdge R430 Owner's Manual Regulatory Model: E28S Series Regulatory Type: E28S001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

Dell PowerEdge R300 Systems Hardware Owner s Manual

Dell PowerEdge R300 Systems Hardware Owner s Manual Dell PowerEdge R300 Systems Hardware Owner s Manual www.dell.com support.dell.com Notes, Notices, and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

DNS-2608 Enterprise JBOD Enclosure User Manual

DNS-2608 Enterprise JBOD Enclosure User Manual DNS-2608 Enterprise JBOD Enclosure User Manual Nov.2017 Copyright DataON. All rights reserved. www.dataonstorage.com 1 Contents Package Contents... 3 System Requirements... 3 Technical Support... 3 DataON

More information

Dell PowerEdge R520 Owner's Manual

Dell PowerEdge R520 Owner's Manual Dell PowerEdge R520 Owner's Manual Regulatory Model: E19S Series Regulatory Type: E19S001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

v02.54 (C) Copyright , American Megatrends, Inc.

v02.54 (C) Copyright , American Megatrends, Inc. 1 Main Advanced H/W Monitor Boot Security Exit System Overview System Time System Date BIOS Version Processor Type Processor Speed Cache Size [ 14:00:09] [Fri 05/19/2006] : ConRoe865PE BIOS P1.00 : Intel

More information

Dell PowerEdge T330 Owner's Manual

Dell PowerEdge T330 Owner's Manual Dell PowerEdge T330 Owner's Manual Regulatory Model: E35S Series Regulatory Type: E35S001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

v02.54 (C) Copyright , American Megatrends, Inc.

v02.54 (C) Copyright , American Megatrends, Inc. 1 Main Advanced H/W Monitor Boot Security Exit System Overview System Time System Date [ 14:00:09] [Tue 02/21/2006] BIOS Version : P4i65G BIOS P1.00 Processor Type : Intel (R) Pentium (R) 4 CPU 2.40 GHz

More information

Troubleshooting. Resetting the System. Problems Following Initial System Installation. First Steps Checklist CHAPTER

Troubleshooting. Resetting the System. Problems Following Initial System Installation. First Steps Checklist CHAPTER CHAPTER 6 This chapter helps you identify and solve problems that might occur while you are using the Cisco CDE110. If you are unable to resolve your server problems on your own, contact Cisco Technical

More information

Dell PowerEdge M620 Systems Owner's Manual

Dell PowerEdge M620 Systems Owner's Manual Dell PowerEdge M620 Systems Owner's Manual Regulatory Model: HHB Regulatory Type: HHB003 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

Dell PowerEdge M620 Systems (For Dell PowerEdge VRTX Enclosure) Owner's Manual

Dell PowerEdge M620 Systems (For Dell PowerEdge VRTX Enclosure) Owner's Manual Dell PowerEdge M620 Systems (For Dell PowerEdge VRTX Enclosure) Owner's Manual Regulatory Model: HHB Regulatory Type: HHB003 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that

More information

Dell PowerEdge M820 Systems Owner's Manual

Dell PowerEdge M820 Systems Owner's Manual Dell PowerEdge M820 Systems Owner's Manual Regulatory Model: FHB Regulatory Type: FHB007 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

This chapter tells how to configure the system by setting the BIOS parameters. 3.1 Entering the AMI BIOS Setup

This chapter tells how to configure the system by setting the BIOS parameters. 3.1 Entering the AMI BIOS Setup Chapter 3 AMI BIOS This chapter tells how to configure the system by setting the BIOS parameters. 3.1 Entering the AMI BIOS Setup To enter the AMI BIOS Setup, press appears as shown below.. The AMI BIOS

More information

Fujitsu LifeBook N Series

Fujitsu LifeBook N Series Fujitsu LifeBook N Series BIOS Guide LifeBook N Series Models: N6400 Document Date: 07/16/2007 Document Part Number: FPC58-1702-01 FUJITSU COMPUTER SYSTEMS CORPORATION 1 LifeBook N Series BIOS N Series

More information

Fujitsu LifeBook A Series

Fujitsu LifeBook A Series Fujitsu LifeBook A Series BIOS Guide LifeBook A Series Model: A6030 Document Date: 06/06/2007 Document Part Number: FPC58-1698-01 FUJITSU COMPUTER SYSTEMS CORPORATION 1 LifeBook A Series BIOS A Series

More information

Dell PowerVault MD3800i and MD3820i Storage Arrays Owner's Manual

Dell PowerVault MD3800i and MD3820i Storage Arrays Owner's Manual Dell PowerVault MD3800i and MD3820i Storage Arrays Owner's Manual Regulatory Model: E03J and E04J Series Regulatory Type: E03J001 and E04J001 Notes, cautions, and warnings NOTE: A NOTE indicates important

More information

1/6. Main. Bios Version System Time System Date Hide Diagnostic Messages During Enabled Disabled POST Error Pause. Processor.

1/6. Main. Bios Version System Time System Date Hide Diagnostic Messages During Enabled Disabled POST Error Pause. Processor. 2006 3 Main ( ) Bios Version BIOS System Time System Date Hide Diagnostic Messages During Enabled Disabled POST Error Pause Enabled Disabled Processor ( ) Core Frequency CPU Bus Frequency CPU FSB Processor

More information

NOVASCALE. NovaScale R430 F2. Hardware Owner's Manual REFERENCE 86 A1 62FD 00

NOVASCALE. NovaScale R430 F2. Hardware Owner's Manual REFERENCE 86 A1 62FD 00 NovaScale R430 F2 NOVASCALE Hardware Owner's Manual REFERENCE 86 A1 62FD 00 NOVASCALE NovaScale R430 F2 Hardware Owner's Manual Hardware December 2009 BULL CEDOC 357 AVENUE PATTON B.P.20845 49008 ANGERS

More information

Dell XC6320 Web-Scaled Hyperconverged Appliance Owner's Manual

Dell XC6320 Web-Scaled Hyperconverged Appliance Owner's Manual Dell XC6320 Web-Scaled Hyperconverged Appliance Owner's Manual Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION

More information

P4B533-X. Motherboard

P4B533-X. Motherboard P4B533-X Motherboard C1458 2003 2 3 4 5 6 7 1 2 2 3 Jumper Mode Jumper Free (Default) 8 9 10 1-1 1-2 1-3 1-4 SB_PWR1 P4B533-X P4B533-X Onboard LED ON Standby Power OFF Powered Off 1-5 CPU_FAN1 ATX12V1

More information

BIOS SETUP UTILITY Main Smart Advanced H/W Monitor Boot Security Exit. v02.54 (C) Copyright , American Megatrends, Inc. BIOS SETUP UTILITY

BIOS SETUP UTILITY Main Smart Advanced H/W Monitor Boot Security Exit. v02.54 (C) Copyright , American Megatrends, Inc. BIOS SETUP UTILITY 1 BIOS SETUP UTILITY Main Smart Advanced H/W Monitor Boot Security Exit System Overview System Time System Date BIOS Version Processor Type Processor Speed Microcode Update Cache Size Total Memory DDRII

More information

BIOS SETUP UTILITY Main Advanced H/W Monitor Boot Security Exit. v02.54 (C) Copyright , American Megatrends, Inc. BIOS SETUP UTILITY

BIOS SETUP UTILITY Main Advanced H/W Monitor Boot Security Exit. v02.54 (C) Copyright , American Megatrends, Inc. BIOS SETUP UTILITY 1 Main Advanced H/W Monitor Boot Security Exit System Overview System Time System Date BIOS Version Processor Type Processor Speed : 3200MHz Microcode Update : 10676/606 Cache Size : 12288KB Total Memory

More information

Fujitsu LifeBook P Series

Fujitsu LifeBook P Series Fujitsu LifeBook P Series BIOS Guide LifeBook P Series Model: P771 Document Date: 2/18/2011 Document Part Number: FPC58-2855-01 FUJITSU AMERICA, INCORPORATED 1 LIFEBOOK P771 BIOS P Series BIOS BIOS SETUP

More information

Fujitsu LifeBook T Series

Fujitsu LifeBook T Series Fujitsu LifeBook T Series BIOS Guide LifeBook T Series Model: T5010 - UMTS Model Document Date: 02/18/2009 Document Part Number: FPC58-2036-01 FUJITSU COMPUTER SYSTEMS CORPORATION 1 LifeBook T Series BIOS

More information

Dell DSS 7000/DSS 7500 Owner's Manual

Dell DSS 7000/DSS 7500 Owner's Manual Dell DSS 7000/DSS 7500 Owner's Manual Regulatory Model: B14S Regulatory Type: B14S001 Notes, Cautions and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

Dell PowerEdge M830 Owner's Manual

Dell PowerEdge M830 Owner's Manual Dell PowerEdge M830 Owner's Manual Regulatory Model: FHB Regulatory Type: FHB008 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

Dell PowerEdge FD332. Owner's Manual. Regulatory Model: E02B Regulatory Type: E02B003

Dell PowerEdge FD332. Owner's Manual. Regulatory Model: E02B Regulatory Type: E02B003 Dell PowerEdge FD332 Owner's Manual Regulatory Model: E02B Regulatory Type: E02B003 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

v02.54 (C) Copyright , American Megatrends, Inc.

v02.54 (C) Copyright , American Megatrends, Inc. 1 Main Advanced H/W Monitor Boot Security Exit System Overview System Time System Date BIOS Version Processor Type Processor Speed Microcode Update Cache Size Total Memory DDR 1 DDR 2 [ 14:00:09] [Tue

More information

Dell Storage MD1400 Enclosures Hardware Owner's Manual

Dell Storage MD1400 Enclosures Hardware Owner's Manual Dell Storage MD1400 Enclosures Hardware Owner's Manual Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates

More information

Dell XPS 14z Owner s Manual

Dell XPS 14z Owner s Manual Dell XPS 14z Owner s Manual Computer model: L412z Regulatory model: P24G series Regulatory type: P24G001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better

More information

Fujitsu LifeBook N Series

Fujitsu LifeBook N Series Fujitsu LifeBook N Series BIOS Guide LifeBook N Series Models: NH570 Document Date: 02/01/2010 Document Part Number: FPC58-2649-01 FUJITSU AMERICA, INC. 1 LifeBook N Series BIOS N Series BIOS BIOS SETUP

More information

Troubleshooting the System Hardware

Troubleshooting the System Hardware CHAPTER 5 This chapter provides basic troubleshooting information to help you identify some common problems that might occur with your Wide Area Virtualization Engine (WAVE). This chapter contains the

More information

Dell XC630 Web-Scale Hyperconverged Appliance Owner's Manual

Dell XC630 Web-Scale Hyperconverged Appliance Owner's Manual Dell XC630 Web-Scale Hyperconverged Appliance Owner's Manual Regulatory Model: E14S Series Regulatory Type: E14S001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps

More information

Dell PowerEdge FM120x4 Owner's Manual

Dell PowerEdge FM120x4 Owner's Manual Dell PowerEdge FM120x4 Owner's Manual Regulatory Model: E02B Regulatory Type: E02B002 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

Fujitsu LifeBook E Series

Fujitsu LifeBook E Series Fujitsu LifeBook E Series BIOS Guide LifeBook E Series Model: E8420 Document Date: 07/10/2008 Document Part Number: FPC58-1911-01 FUJITSU COMPUTER SYSTEMS CORPORATION 1 LifeBook E Series BIOS E Series

More information

Fujitsu LifeBook U Series

Fujitsu LifeBook U Series Fujitsu LifeBook U Series BIOS Guide LifeBook U Series Model: UH900 Document Date: 01/07/2010 Document Part Number: FPC58-2547-01 FUJITSU AMERICA, INC. 1 LifeBook U Series BIOS U Series BIOS BIOS SETUP

More information

Dell PowerEdge T130 Owner's Manual

Dell PowerEdge T130 Owner's Manual Dell PowerEdge T130 Owner's Manual Regulatory Model: E36S Series Regulatory Type: E36S001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

Fujitsu LifeBook T Series

Fujitsu LifeBook T Series Fujitsu LifeBook T Series BIOS Guide LifeBook T Series Model: T1010 with UMTS Document Date: 01/15/2009 Document Part Number: FPC58-2038-01 FUJITSU COMPUTER SYSTEMS CORPORATION 1 LifeBook T Series BIOS

More information

Computer Setup (F10) Utility Guide HP Business Desktops dx5150 model

Computer Setup (F10) Utility Guide HP Business Desktops dx5150 model Guide HP Business Desktops dx5150 model Document Part Number: 374172-001 December 2004 This guide provides instructions on how to use Computer Setup. This tool is used to reconfigure and modify computer

More information

Alienware X51 Service Manual

Alienware X51 Service Manual Alienware X51 Service Manual Computer Model: Alienware X51 R3 Regulatory Model: D05S Regulatory Type: D05S003 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make

More information

Fujitsu LifeBook A Series

Fujitsu LifeBook A Series Fujitsu LifeBook A Series BIOS Guide LifeBook A Series Model: AH530 Document Date: 06/09/2010 Document Part Number: FPC58-2714-01 FUJITSU AMERICA, INC. 1 LifeBook PH520 BIOS A Series BIOS BIOS SETUP UTILITY

More information

Dell PowerEdge T430 Owner's Manual

Dell PowerEdge T430 Owner's Manual Dell PowerEdge T430 Owner's Manual Regulatory Model: E30S Series Regulatory Type: E30S001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

NGFW Security Management Center Appliance. for Forcepoint Next Generation Firewall Hardware Guide. Revision B

NGFW Security Management Center Appliance. for Forcepoint Next Generation Firewall Hardware Guide. Revision B NGFW Security Management Center Appliance for Forcepoint Next Generation Firewall Hardware Guide Revision B Contents Introduction on page 2 Find product documentation on page 2 Supported software on page

More information

E Series BIOS BIOS SETUP UTILITY. Entering the BIOS Setup Utility. Entering the Setup Utility After a Configuration Change or System Failure

E Series BIOS BIOS SETUP UTILITY. Entering the BIOS Setup Utility. Entering the Setup Utility After a Configuration Change or System Failure BIOS SECTION E8020 LifeBook E Series BIOS E Series BIOS BIOS SETUP UTILITY The BIOS Setup Utility is a program that sets up the operating environment for your notebook. Your BIOS is set at the factory

More information

BIOS Parameters by Server Model

BIOS Parameters by Server Model BIOS Parameters by Server Model This appendix contains the following sections: C22 and C24 Servers, page 1 C200 and C210 Servers, page 16 C220 and C240 Servers, page 29 C250 Servers, page 44 C260 Servers,

More information

Dell PowerEdge R430. Owner's Manual. Regulatory Model: E28S Series Regulatory Type: E28S001

Dell PowerEdge R430. Owner's Manual. Regulatory Model: E28S Series Regulatory Type: E28S001 Dell PowerEdge R430 Owner's Manual Regulatory Model: E28S Series Regulatory Type: E28S001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

Fujitsu LifeBook A & V Series

Fujitsu LifeBook A & V Series Fujitsu LifeBook A & V Series BIOS Guide LifeBook A & V Series Models: A1110/A1120 V1030 Document Date: 10/01/2008 Document Part Number: FPC65-4363-01 FUJITSU COMPUTER SYSTEMS CORPORATION 1 LifeBook A1110/V1030

More information

N Series BIOS BIOS SETUP UTILITY

N Series BIOS BIOS SETUP UTILITY BIOS SECTION N3530 LifeBook N Series Notebook BIOS N Series BIOS BIOS SETUP UTILITY The BIOS Setup Utility is a program that sets up the operating environment for your notebook. Your BIOS is set at the

More information

Fujitsu LifeBook T Series

Fujitsu LifeBook T Series Fujitsu LifeBook T Series BIOS Guide LifeBook T Series Model: T3010/T3010D Document Date: 09/16/03 Document Part Number: FPC58-0992-01 FUJITSU PC CORPORATION 1 LifeBook T Series Tablet PC T Series BIOS

More information

BIOS SETUP UTILITY Main Advanced H/W Monitor Boot Security Exit. v02.54 (C) Copyright , American Megatrends, Inc. BIOS SETUP UTILITY

BIOS SETUP UTILITY Main Advanced H/W Monitor Boot Security Exit. v02.54 (C) Copyright , American Megatrends, Inc. BIOS SETUP UTILITY 1 Main Advanced H/W Monitor Boot Security Exit System Overview System Time System Date Total Memory DDR1 DDR2 [ 16:15:31] [Mon 12/25/2006] BIOS Version : P4VM890 BIOS P1.00 Processor Type : Intel (R) Pentium

More information

S Series BIOS BIOS SETUP UTILITY. Entering the BIOS Setup Utility. Entering the Setup Utility After a Configuration Change or System Failure

S Series BIOS BIOS SETUP UTILITY. Entering the BIOS Setup Utility. Entering the Setup Utility After a Configuration Change or System Failure BIOS SECTION S6130 LifeBook S Series Notebook BIOS S Series BIOS BIOS SETUP UTILITY The BIOS Setup Utility is a program that sets up the operating environment for your notebook. Your BIOS is set at the

More information

BIOS SETUP UTILITY. v02.54 (C) Copyright , American Megatrends, Inc. BIOS SETUP UTILITY

BIOS SETUP UTILITY. v02.54 (C) Copyright , American Megatrends, Inc. BIOS SETUP UTILITY 1 Main OC Tweaker Advanced H/W Monitor Boot Security Exit System Overview System Time System Date BIOS Version Processor Type Processor Speed : 3200MHz Microcode Update : 106A4/10 Cache Size : 8192KB Total

More information

Reinstalling the Operating System on the Dell PowerVault 745N

Reinstalling the Operating System on the Dell PowerVault 745N Reinstalling the Operating System on the Dell PowerVault 745N This document details the following steps to reinstall the operating system on a PowerVault 745N system: 1. Install the Reinstallation Console

More information

BIOS Update Release Notes

BIOS Update Release Notes PRODUCTS: DH87RL (Standard BIOS) BIOS Update Release Notes BIOS Version 0331 - RLH8710H.86A.0331.2018.0327.1252 Date: March 27, 2018 Integrated Graphics: Option ROM: Build 2179 PC 14.34 SATA RAID UEFI

More information

Fujitsu LifeBook T Series

Fujitsu LifeBook T Series Fujitsu LifeBook T Series BIOS Guide LifeBook T Series Models: T900 Document Date: 02/03/2010 Document Part Number: FPC58-2643-01 FUJITSU AMERICA, INCORPORATED 1 LifeBook T Series BIOS T Series BIOS BIOS

More information

Chapter 4 Using BIOS 1

Chapter 4 Using BIOS 1 Chapter 1 Using BIOS 4 4.1 About the Setup Utility The computer uses the latest American Megatrends Inc. BIOS with support for Windows Plug and Play. The CMOS chip on the motherboard contains the ROM setup

More information

Dell PowerEdge R630. Owner's Manual. Regulatory Model: E26S Series Regulatory Type: E26S001

Dell PowerEdge R630. Owner's Manual. Regulatory Model: E26S Series Regulatory Type: E26S001 Dell PowerEdge R630 Owner's Manual Regulatory Model: E26S Series Regulatory Type: E26S001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

The list below shows items not included with a SmartVDI-110 Server. Monitors Ethernet cables (copper) Fiber optic cables Keyboard and mouse

The list below shows items not included with a SmartVDI-110 Server. Monitors Ethernet cables (copper) Fiber optic cables Keyboard and mouse SmartVDI-110 Server Quick Start Guide Container Contents Included in container The list below shows components included in a SmartVDI-110 container. SmartVDI-110 Server Chassis mounting rails and hardware

More information

BIOS SECTION S6210/6220

BIOS SECTION S6210/6220 BIOS SECTION S6210/6220 LifeBook S Series Notebook BIOS S Series BIOS BIOS SETUP UTILITY The BIOS Setup Utility is a program that sets up the operating environment for your notebook. Your BIOS is set at

More information

Fujitsu LifeBook P Series

Fujitsu LifeBook P Series Fujitsu LifeBook P Series BIOS Guide LifeBook P Series Model: P8010 Document Date: 01/31/2008 Document Part Number: FPC58-1819-01 FUJITSU COMPUTER SYSTEMS CORPORATION 1 LifeBook P Series BIOS P Series

More information

Fujitsu LifeBook E Series

Fujitsu LifeBook E Series Fujitsu LifeBook E Series BIOS Guide LifeBook E Series Model: E751 Document Date: 3/16/2011 Document Part Number: FPC58-2849-01 FUJITSU AMERICA, INCORPORATED 1 LIFEBOOK E751 BIOS E Series BIOS BIOS SETUP

More information

T Series BIOS BIOS SETUP UTILITY

T Series BIOS BIOS SETUP UTILITY BIOS SECTION T4010 LifeBook T Series Tablet PC T Series BIOS BIOS SETUP UTILITY The BIOS Setup Utility is a program that sets up the operating environment for your tablet. Your BIOS is set at the factory

More information

BIOS SETUP UTILITY Main Smart Advanced H/W Monitor Boot Security Exit. v02.54 (C) Copyright , American Megatrends, Inc.

BIOS SETUP UTILITY Main Smart Advanced H/W Monitor Boot Security Exit. v02.54 (C) Copyright , American Megatrends, Inc. 1 Main Smart Advanced H/W Monitor Boot Security Exit System Overview System Time System Date BIOS Version Processor Type Processor Speed Microcode Update L1 Cache Size L2 Cache Size Total Memory DDRII_1

More information

Fujitsu Stylistic ST6000 Series

Fujitsu Stylistic ST6000 Series Fujitsu Stylistic ST6000 Series BIOS Guide Stylistic Series Model: ST6012 Document Date: 12/01/2008 Document Part Number: FPC65-4369-01 FUJITSU COMPUTER SYSTEMS CORPORATION 1 Stylistic ST Series BIOS ST

More information

BIOS SETUP UTILITY Main Advanced H/W Monitor Boot Security Exit. v02.54 (C) Copyright , American Megatrends, Inc. BIOS SETUP UTILITY

BIOS SETUP UTILITY Main Advanced H/W Monitor Boot Security Exit. v02.54 (C) Copyright , American Megatrends, Inc. BIOS SETUP UTILITY 1 Main Advanced H/W Monitor Boot Security Exit System Overview System Time System Date BIOS Version Processor Type Processor Speed : 2666MHz Microcode Update : 10676/60B Cache Size : 3072KB Total Memory

More information

BIOS SETUP UTILITY. v02.54 (C) Copyright , American Megatrends, Inc. BIOS SETUP UTILITY

BIOS SETUP UTILITY. v02.54 (C) Copyright , American Megatrends, Inc. BIOS SETUP UTILITY 1 Main Smart Advanced H/W Monitor Boot Security Exit System Overview System Time System Date BIOS Version Processor Type Processor Speed Microcode Update Cache Size Total Memory DDRII1 DDRII2 : G41M-GS

More information

Dell Inspiron 660 Owner s Manual

Dell Inspiron 660 Owner s Manual Dell Inspiron 660 Owner s Manual Computer model: Inspiron 660 Regulatory model: D11M Regulatory type: D11M002 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make

More information

Computer Hardware Trouble Shooting or The computer won t work!!! Now what am I going to do?

Computer Hardware Trouble Shooting or The computer won t work!!! Now what am I going to do? Computer Hardware Trouble Shooting or The computer won t work!!! Now what am I going to do? Basic steps for diagnosing computer problems: 1. Look and listen the computer will give you some hints about

More information

Fujitsu LifeBook T Series

Fujitsu LifeBook T Series Fujitsu LifeBook T Series BIOS Guide LifeBook T Series Model: T580 Document Date: 12/10/2010 Document Part Number: FPC58-2801-01 FUJITSU AMERICA, INCORPORATED 1 LIFEBOOK T580 BIOS T Series BIOS BIOS SETUP

More information

Dell PowerEdge T20 Owner's Manual

Dell PowerEdge T20 Owner's Manual Dell PowerEdge T20 Owner's Manual Regulatory Model: D13M Regulatory Type: D13M001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

BIOS SETUP UTILITY Main Advanced H/W Monitor Boot Security Exit. v02.54 (C) Copyright , American Megatrends, Inc. BIOS SETUP UTILITY

BIOS SETUP UTILITY Main Advanced H/W Monitor Boot Security Exit. v02.54 (C) Copyright , American Megatrends, Inc. BIOS SETUP UTILITY 1 Main H/W Monitor Boot Security Exit System Overview System Time System Date BIOS Version Processor Type Processor Speed : 3400MHz Microcode Update : F64/4 Cache Size : 2048KB Total Memory DDRII 1 DDRII

More information

Fujitsu LifeBook S Series

Fujitsu LifeBook S Series Fujitsu LifeBook S Series BIOS Guide LifeBook S Series Model: S2020 Document Date: 10/30/03 Document Part Number: FPC58-1035-01 FUJITSU COMPUTER SYSTEMS 1 LifeBook S Series Notebook BIOS S Series BIOS

More information

BIOS SETUP UTILITY Main Smart Advanced H/W Monitor Boot Security Exit. v02.54 (C) Copyright , American Megatrends, Inc. BIOS SETUP UTILITY

BIOS SETUP UTILITY Main Smart Advanced H/W Monitor Boot Security Exit. v02.54 (C) Copyright , American Megatrends, Inc. BIOS SETUP UTILITY 1 Main Smart Advanced H/W Monitor Boot Security Exit System Overview System Time System Date BIOS Version Processor Type Processor Speed : 2666MHz Microcode Update : 10676/60B Cache Size : 3072KB Total

More information

BIOS Setup DESKPOWER 6000

BIOS Setup DESKPOWER 6000 BIOS Setup DESKPOWER 6000 1 Preface What is BIOS setup? BIOS setup is a program that helps the user set up a hardware environment, including memory, hard disks, and floppy disk drives. Minimum setup has

More information

Fujitsu LifeBook E Series

Fujitsu LifeBook E Series Fujitsu LifeBook E Series BIOS Guide LifeBook E Series Model: E8410 Document Date: 05/25/2007 Document Part Number: FPC58-1690-01 FUJITSU COMPUTER SYSTEMS CORPORATION 1 LifeBook E Series BIOS E Series

More information

Dell Vostro 3252 Owner's Manual

Dell Vostro 3252 Owner's Manual Dell Vostro 3252 Owner's Manual Regulatory Model: D14S Regulatory Type: D14S001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

BIOS Update Release Notes

BIOS Update Release Notes BIOS Update Release Notes PRODUCTS: DZ77GA-70K, DZ77RE-75K (Standard BIOS) BIOS Version 0066 - GAZ7711H.86A.0066.2013.0521.1509 Date: May 21, 2013 ME Firmware: 8.1.20.1336 Fixed blue screen error when

More information

v02.54 (C) Copyright , American Megatrends, Inc. BIOS SETUP UTILITY v02.54 (C) Copyright , American Megatrends, Inc.

v02.54 (C) Copyright , American Megatrends, Inc. BIOS SETUP UTILITY v02.54 (C) Copyright , American Megatrends, Inc. 1 Main OC Tweaker Advanced H/W Monitor Boot Security Exit System Overview System Time System Date BIOS Version Processor Type Processor Speed Microcode Update Cache Size Total Memory DDRII1 DDRII2 DDR3_1

More information

Dell EMC XC430 Xpress Hyper-converged Appliance. Service and Installation Manual

Dell EMC XC430 Xpress Hyper-converged Appliance. Service and Installation Manual Dell EMC XC430 Xpress Hyper-converged Appliance Service and Installation Manual Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product.

More information

LifeBook P Series Notebook BIOS

LifeBook P Series Notebook BIOS BIOS SECTION P1610 LifeBook P1600 Notebook BIOS LifeBook P Series Notebook BIOS BIOS SETUP UTILITY The BIOS Setup Utility is a program that sets up the operating environment for your notebook. Your BIOS

More information

Fujitsu LifeBook E Series

Fujitsu LifeBook E Series Fujitsu LifeBook E Series BIOS Guide LifeBook E Series Models: E2010 Document Date: 02/05/03 Document Part Number: FPC58-0881-01 F U J I T S U P C C O R P O R A T I O N 1 LifeBook E Series BIOS E Series

More information

BIOS Setup DESKPOWER 5000

BIOS Setup DESKPOWER 5000 BIOS Setup DESKPOWER 5000 1 Preface What is BIOS setup? BIOS setup is a program that helps the user set up a hardware environment, including memory, hard disks, and floppy disk drives. Minimum setup has

More information

Troubleshooting & Repair

Troubleshooting & Repair Chapter Troubleshooting & Repair 6.1 Introduction This chapter provides the most common problem encountered with the M785 notebook computer and some troubleshooting means. Some of the common problems are:

More information

Dell Inspiron N5110 Service Manual

Dell Inspiron N5110 Service Manual Dell Inspiron N5110 Service Manual Regulatory model: P17F Regulatory type: P17F001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

BIOS User Guide RACING P1A

BIOS User Guide RACING P1A BIOS User Guide RACING P1A BIOS Update... 2 UEFI BIOS Setup... 6 1. Main Menu... 7 2. Advanced Menu... 8 3. Chipset Menu...14 4. Security Menu...20 5. Boot Menu...23 6. Exit Menu...25 BIOS Update The BIOS

More information

Fujitsu LifeBook T Series

Fujitsu LifeBook T Series Fujitsu LifeBook T Series BIOS Guide LifeBook T Series Model: T4020/T4020D Document Date: 08/08/2005 Document Part Number: FPC58-1407-01 FUJITSU COMPUTER SYSTEMS 1 LifeBook T Series Tablet PC T Series

More information