DNS-2608 Enterprise JBOD Enclosure User Manual

Size: px
Start display at page:

Download "DNS-2608 Enterprise JBOD Enclosure User Manual"

Transcription

1 DNS-2608 Enterprise JBOD Enclosure User Manual Nov.2017 Copyright DataON. All rights reserved.

2 1

3 Contents Package Contents... 3 System Requirements... 3 Technical Support... 3 DataON DNS-2608 Specifications... 4 System Front View and HDD Location... 5 LEDs on the Storage Enclosure... 6 Rear View... 7 SIM Board LED Descriptions... 8 PSM Board Descriptions System Fan and SSD Module Front Loading Carrier Rear Loading Carrier Install/Replace SAS Disk Power on the DNS Trademarks Disclaimer Safety Measures

4 Package Contents The DataON DNS-2608 Enterprise JBOD Enclosure box contains the following items: (1) DataON DNS-2608 storage appliance (2) Power cords for US customers only (1) CD with the user manual and drivers (1) Universal rail kit for the DNS (96) HDD screws System Requirements SFF-8644 to SFF Gbps SAS cable(s) For servers with supported HBA/RAID adapters, refer to the DNS-2608 support matrix for a complete list of supported adapters Technical Support Please visit our website at 3

5 DataON DNS-2608 Specifications Form Factor Drive Support Drive Form Factor 4U 32-bary 24x 3.5 (front) + 8x 2.5 (rear) 12Gb/s SAS 3.0 HDD and SDD (24) 3.5 /2.5 Hot-swappable 12Gb SAS drive tray with front access (8) 2.5 Hot-swappable 12Gb SAS drive tray I/O Controller Host Interface Controller Support Disk Drive Enclosure Cooling Power Supply (2) 12Gb/s SAS 3.0 (Avago SAS 3x48 expander) I/O modules (4) 12Gb/s Mini-SAS HD host ports via four SFF Gb/s HBAs and host-based RAID controller cards with external connectivity Hot-swap (32 bays) 2x 60mm fan for system + 2x 40mm fan for the SSD module Dual redundant power supply 2x 500W Platinum 110/220V AC LED Indicators *Identify enclosure *Power on & activity *Drive fault *Identify drive *Hot space *Drive rebuild *Power *I/O Module status *System Enclosure Dimensions Weight Operational Environment 7.56 H x 17.6 W x D 46.3lbs (enclosure only) Operating temperature 0 C to 40 C (32 F to 104 F) Non-operating temperature -40 C to 65 C (-40 F to 149 F) Operating relative humidity 20% to 85%RH. Non-operating relative humidity 10% to 90%RH 4

6 System Front View and HDD Location Number Component Description 1 Control panel The control panel includes the following LEDs and buttons: Power button with LED Status LED ID button ID LED 2 Thumb screw Secure the system to the rack. 3 Handle Hold with care and extend out the system from the rack when the rail kit is installed. The handle is not designed to carry this system. 4 Storage drive bay Houses the front-loading hot-plug 2.5 /3.5 SA/SATA HDDs/SSDs. 5

7 LEDs on the Storage Enclosure Number Component Color Lights On Lights Off 1 Power Green Power on Power off 2 Fault LED Amber Amber on: system failed* Normal Amber blinking (two times per second): rear SSD failed Amber blinking (four times per second): system failed + rear SSD failed* 3 Locate LED Flashing blue Identifies a storage enclosure. Normal 4 ID Button Press to toggle on/off the ID/LED 6

8 Rear View Important: Note the direction of the power supply unit. Insert the power supply with the right direction. All SAS port connectors are Mini-SAS HD (SFF-8644). 7

9 SIM Board LED Descriptions Number Component Color Lights On Lights Off 1 Service port Description: Mini-USB connector. Connects to local system for maintenance or debugging. 2 Mini-SAS HD ports Description: Mini-SAS HD connector. Connects to server system. Left ~ Right: Host 0 ~ Host 3: Host 0/3 for cascade in/out 3 Mini-SAS port status Amber Connection/PHY s link failed Status normal 4 Mini-SAS HD port activity LED Blue Connection established No connection 5 Link LED Amber Green Amber on: 1000Mbps connection Green on: 100Mbps connection Off: 10Mbps connection when activity LED blinking Off: Disconnected when activity LED off 6 Management port Manage the system from the remote connection through the GbE RJ45 management port for maintenance or debugging. 7 Activity LED Green Blinking: connected Disconnected 8

10 8 ID LED Flashing blue SIM identified Normal 9 Status LED Amber Failed Status good 10 Power LED Blue Power on Power off 9

11 PSM Board Descriptions Number Component Color Lights On Lights Off 1 Fan Cooling the power supply unit. 2 DC Power Green Amber Green: AC power on Green blinking (2/sec): Standby Green blinking (4/sec): Sleep mode Amber: Failed No AC power 3 Socket Connects to power cord. 4 Latch Press to release the latch. 5 Handle Pull out and hold the handle with hands for removing the PSU from the chassis bay. 10

12 System Fan and SSD Module Number Component Color Lights On Lights Off 1 Latch Press to release the latch of the SSD fan module. 2 Handle Pull out and hold the handle for removing the fan module from the chassis bay. 3 Fan LED Amber Failed Status good Note: To avoid system overheating, replace the fan module within 10 minutes. 11

13 Front Loading Carrier Number Component Color Lights On Lights Off 1 Handle Hold and pull the carrier out with care. The handle is not designed to carry the storage drive. 2 Release button Press to release the handle 3 Activity Blue Access active 4 Present/Fault Blue Present Slot empty Blinking blue, 2 per second Blinking blue, 1 per second Disk fault Rebuilding Slot empty Slot empty Amber Failed Slot empty 12

14 Rear Loading Carrier Number Component Color Lights On Lights Off 1 Handle Hold and pull the carrier out with care. The handle is not designed to carry the storage drive. SAS disk is ready 2 Release button Press to release the handle 3 Present/Fault Blue Present Slot empty Blinking blue, 2 per second Blinking blue, 1 per second Disk fault Rebuilding Slot empty Slot empty Amber Failed Slot empty 4 Activity Blue Access active 13

15 Install/Replace SAS Disk Before You Begin It is not recommended mixing different SAS SSDs and SAS HDDs in the same DNS-2608 system. If it is necessary, please use the following figures below to plan where you will be placing the disk drives. These figures represent a fully-loaded DNS-2608 system with SAS disks. However, the same guidelines apply even if you are filling some of the disk slots with blank disk trays in the mixing disk setting. Single-Zone Mode Single-zone mode has 4 mini-sas HD host post, 8 SSDs and 24 HDDs. Two-Zone Mode Two-zone mode has 2 mini-sas HD host posts, 4 SSDs and 12 HDDs as shown for each zone as shown. Note: SIM 1 does not support SATA device status. 14

16 Power on the DNS Verify that all connections are correct 2. Turn on both circuit breakers on the cabinet. 3. Make sure the power on LEDs on all DNS-2608 systems are steady blue. 4. Power on the host last. Please make sure to power on all DNS-2608 systems first before the server. 15

17 Trademarks DataON and the DataON logo, and MUST are trademarks of DataON in the United States. The following terms are trademarks of other companies: Intel, Xeon, and the Intel logo are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Active Directory, Hyper-V, Microsoft, SQL Server, Windows, Windows Server, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both. Other company, product, or service names may be trademarks or service marks of others. Disclaimer The information in this document is subject to change without notice. DataON makes no representations or warranties with respect to the contents hereof and specifically disclaim any implied warranties of merchantability or fitness for any particular purpose. DataON reserves the right to revise this publication and to make changes from time to time in the content without obligation to notify any person of such revision or changes. Safety Measures Computer components and electronic circuit boards can be damaged by discharges of static electricity. Working on computers that are still connected to a power supply can be extremely dangerous. Follow these guidelines to avoid damage to the DNS-2608 or injury to yourself. Always disconnect power when carrying out work inside the unit. If possible, wear a grounded wrist strap when carrying out work inside the unit. Alternatively, discharge and static by touching the bare metal chassis of the unit case, or the bare metal body of any other grounded appliance. Hold electronic circuit boards by the edges only. Do not touch the components on the board unless it is necessary to do so. Do not flex or stress the circuit board. Leave all components inside the static-proof packaging until you are ready to install the component. Version 2.0 / November

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems.

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems. DNS-2670 User Manual Version Dec. 2015 DataON Storage, storage division of Area Data Systems. Contents 1 Introduction... 1 1.1 System Overview... 3 1.1.1 System Top View...3 1.1.2 Front View...4 1.1.3

More information

ETERNUS JX60. Technical Product Introduction. 0 Copyright Fujitsu, Release June 2014

ETERNUS JX60. Technical Product Introduction. 0 Copyright Fujitsu, Release June 2014 0 Copyright Fujitsu, Release June 2014 Highlights The passive storage subsystem accommodates up to 240 HDDs 3.5" SAS 2.0 Nearline SAS 7200 rpm, max. storage capacity 960 TB 1) One or two 6 Gbit/s SAS interfaces

More information

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual Regulatory Model: E03J, E04J Regulatory Type: E03J001, E04J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2 SAS to SAS/SATA JBOD Subsystem Revision 1.2 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Subsystem... 6 1.4 Identifying Parts

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1 SAS to SAS/SATA JBOD Subsystem Revision 1.1 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Expansion Chassis... 6 1.4 Identifying

More information

Dell EMC Storage MD1280 Enclosure Owner's Manual

Dell EMC Storage MD1280 Enclosure Owner's Manual Dell EMC Storage MD1280 Enclosure Owner's Manual Regulatory Model: SP-2584, E11J Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product.

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1 SAS to SAS/SATA JBOD Subsystem Revision 1.1 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Expansion Chassis... 6 1.4 Identifying

More information

64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0 64 Bays SAS to SAS/SATA JBOD Subsystem Revision 1.0 Table of Contents Preface... 4 Before You Begin... 5 Safety Guidelines... 5 Controller Configurations... 5 Packaging, Shipment and Delivery... 5 Unpacking

More information

Veritas Appliance Hardware Service Procedure

Veritas Appliance Hardware Service Procedure Veritas Appliance Hardware Service Procedure Replacing a RAID Controller in a Veritas 5U84 Primary Storage Shelf Document Number: 217 Version: 1.0 (11/06/17) Purpose This document describes the process

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0 SAS to SAS/SATA JBOD Subsystem Revision 1.0 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Terminologies... 6 Chapter 2 Getting Started... 7 2.1 Unpacking

More information

Dell SC5020 and SC5020F Storage System Owner s Manual

Dell SC5020 and SC5020F Storage System Owner s Manual Dell SC5020 and SC5020F Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

Dell SCv3000 and SCv3020 Storage System Owner s Manual

Dell SCv3000 and SCv3020 Storage System Owner s Manual Dell SCv3000 and SCv3020 Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

Dell SC7020 and SC7020F Storage Systems Owner s Manual

Dell SC7020 and SC7020F Storage Systems Owner s Manual Dell SC7020 and SC7020F Storage Systems Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates

More information

SCv3000 and SCv3020 Storage System. Owner s Manual

SCv3000 and SCv3020 Storage System. Owner s Manual SCv3000 and SCv3020 Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

SATA II HDD Canister KISS DA 435 Quick Reference Guide

SATA II HDD Canister KISS DA 435 Quick Reference Guide SATA II HDD Canister KISS DA 435 Quick Reference Guide If it s embedded, it s Kontron 1. Table of Contents SATA II HDD Canister KISS DA 435 1. Table of Contents 1. Table of Contents... 1 2. Important Information...

More information

SAS JBOD Installation Reference Guide Revision 1.0

SAS JBOD Installation Reference Guide Revision 1.0 SAS JBOD 16-bay Rackmount Enclosure Installation Reference Guide Revision 1.0 P/N: PW0020000000281 Copyright No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved.

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved. apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May 2004 2003 Apple Computer, Inc. All rights reserved. apple Service Source Basics Xserve RAID 2003 Apple Computer, Inc.

More information

Veritas Appliance Hardware Service Procedure

Veritas Appliance Hardware Service Procedure Veritas Appliance Hardware Service Procedure I/O module replacement: Veritas 5240 Appliance Storage Shelf Document Number: 158 Version: 4.0 (7/04/16) Purpose This document describes the process for replacing

More information

Dell MD1280 Storage Enclosure Getting Started Guide

Dell MD1280 Storage Enclosure Getting Started Guide Dell MD1280 Storage Enclosure Getting Started Guide Regulatory Model: SP-2584, E11J Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A 3-4 SAS/SATA II HDD Canister Entry version XC-34D1-SA10-0-R USER S MANUAL Document number: MAN-00077-A ii Preface Important Information Warranty Our product is warranted against defects in materials and

More information

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved.

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved. apple Service Source Xserve RAID 17 March 2003 2003 Apple Computer, Inc. All rights reserved. apple Service Source Basics Xserve RAID 2003 Apple Computer, Inc. All rights reserved. Overview Xserve RAID

More information

Tiger Box Expansion Chassis Assembly Guide

Tiger Box Expansion Chassis Assembly Guide Tiger Box Expansion Chassis Assembly Guide Product Overview................................. 3 Tiger Box Expansion Chassis Features............... 3 Package Content............................. 4 Hardware

More information

Veritas Appliance Hardware Service Procedure

Veritas Appliance Hardware Service Procedure Veritas Appliance Hardware Service Procedure Replacing a SAS3 cable in a Veritas storage shelf Document Number: 166 Version: 4.1 (03/05/18) Purpose This document describes the process of replacing the

More information

SGI InfiniteStorage 120

SGI InfiniteStorage 120 SGI InfiniteStorage 120 Mass Storage Hardware Topics Edition 003 007-4853-003 Proprietary Rights Notices COPYRIGHT 2006, 2007 SGI. All rights reserved; provided portions may be copyright in third parties,

More information

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Order Number:

More information

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options CHAPTER 4 Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options This chapter provides instructions for installing, replacing, and removing various hardware options in your Cisco ADE

More information

Rocsecure NE52 NAS System

Rocsecure NE52 NAS System Rocsecure NE52 NAS System Revision 1.0 Table of Contents Preface... 3 Before You Begin... 4 Safety Guidelines... 4 Packaging, Shipment and Delivery... 4 Chapter 1 Introduction... 5 1.1 Key Features...

More information

Dell EMC ME4 Series JBOD 5U84 Enclosure

Dell EMC ME4 Series JBOD 5U84 Enclosure Dell EMC ME4 Series JBOD 5U84 Enclosure Deployment Guide Regulatory Model: E09J, E10J, E11J Regulatory Type: E09J001, E10J001, E11J001 Notes, cautions, and warnings NOTE: A NOTE indicates important information

More information

Dell SC460 Expansion Enclosure Getting Started Guide

Dell SC460 Expansion Enclosure Getting Started Guide Dell SC460 Expansion Enclosure Getting Started Guide Regulatory Model: CYAE Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION:

More information

HP ProLiant DL165 G7 Server

HP ProLiant DL165 G7 Server HP ProLiant DL165 G7 Server Installation Instructions Part Number 601464-003 Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 LFF HDD Item Description 1 Thumbscrews

More information

HP ProLiant SL160z G6 Server

HP ProLiant SL160z G6 Server HP ProLiant SL160z G6 Server Installation Instructions Part Number 571291-004 Item Description 7 UID LED/SW 8 PCI Slot 9 Health LED 10 Power Button Rear Panel Components Figure 2 Rear panel components

More information

Veritas Appliance Hardware Service Procedure

Veritas Appliance Hardware Service Procedure Veritas Appliance Hardware Service Procedure Operating system disk drive and log disk drive replacement - NetBackup 0 Appliance Document Number: 7 Version:.0 (7/0/6) Purpose This document describes the

More information

SCv360 Expansion Enclosure

SCv360 Expansion Enclosure SCv360 Expansion Enclosure Getting Started Guide Regulatory Model: CYAE Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION:

More information

XTM 1050 Replacement Parts Installation

XTM 1050 Replacement Parts Installation XTM 1050 Replacement Parts Installation Instructions to replace or install: Power Supply Chassis Fan Fiber Card 10 Gb Interface Module WARNING! Do not open the XTM 1050 or try to replace or install any

More information

iosafe BDR515 Hardware Guide

iosafe BDR515 Hardware Guide iosafe BDR515 Hardware Guide 910-11762-00 Rev03 HARDWARE GUIDE, BDR515 Table of Contents Chapter 1: Before You Start Package Contents... 3 iosafe at a Glance... 4 Safety Instructions... 5 Chapter 2: Hardware

More information

iosafe SERVER 5 Quick Start Guide

iosafe SERVER 5 Quick Start Guide iosafe SERVER 5 Quick Start Guide 910-11782-00 Rev02 QUICKSTART GUIDE, SERVER 5 Table of Contents Chapter 1: Before You Start Package Contents... 3 iosafe at a Glance... 4 Safety Instructions... 5 Chapter

More information

Next Generation Firewall

Next Generation Firewall Next Generation Firewall Hardware Guide Model 6205 Revision C Contents Introduction on page 2 Find product documentation on page 2 Model 6205 features on page 3 Supported interface modules on page 6 Precautions

More information

Customer Replacement Procedure

Customer Replacement Procedure Customer Replacement Procedure Dell EMC Unity Family Dell EMC Unity All Flash and Unity Hybrid Replacing a faulted 25-drive DAE power supply and cooling module 302-002-598 REV 02 September 2017 This document

More information

NAS System. User s Manual. Revision 1.0

NAS System. User s Manual. Revision 1.0 User s Manual Revision 1.0 Before You Begin efore going through with this manual, you should read and focus on the following safety guidelines. Information about the NAS system s packaging and delivery

More information

Dell SCv3000 and SCv3020 Storage System Getting Started Guide

Dell SCv3000 and SCv3020 Storage System Getting Started Guide Dell SCv3000 and SCv3020 Storage System Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make

More information

1U Device Expansion Unit Configuration Guide

1U Device Expansion Unit Configuration Guide 1U Device Expansion Unit Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper

More information

JanusRAID SA-6692J Hardware User Manual

JanusRAID SA-6692J Hardware User Manual JanusRAID SA-6692J Hardware User Manual 42-30000-5067 SATA II JBOD enclosure Version 1.1 SA-6692J SATA II JBOD enclosure Hardware User Manual Table of Contents Preface... i Chapter 1 System Requirements

More information

Dell SC5020 and SC5020F Storage Systems Getting Started Guide

Dell SC5020 and SC5020F Storage Systems Getting Started Guide Dell SC5020 and SC5020F Storage Systems Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make

More information

NT2 U3. 2-Bay RAID Storage Enclosure. User Manual May 18, 2010 v1.1

NT2 U3. 2-Bay RAID Storage Enclosure. User Manual May 18, 2010 v1.1 2-Bay RAID Storage Enclosure User Manual May 18, 2010 v1.1 EN Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III CPU 500MHz, 128MB RAM Windows Vista, Windows

More information

Dell PowerVault MD3060e Storage Enclosure Owner's Manual

Dell PowerVault MD3060e Storage Enclosure Owner's Manual Dell PowerVault MD3060e Storage Enclosure Owner's Manual Regulatory Model: E08J Series Regulatory Type: E08J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you

More information

Next Generation Firewall

Next Generation Firewall Next Generation Firewall Hardware Guide Model 6205 Revision A Contents Introduction on page 2 Find product documentation on page 2 Model 6205 features on page 3 Supported interface modules on page 6 Precautions

More information

Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure

Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure Scale-Out Smart for HPC and Cloud Computing with enhanced

More information

Veritas Appliance Hardware Service Procedure

Veritas Appliance Hardware Service Procedure Veritas Appliance Hardware Service Procedure Power Supply Replacement: NetBackup 5220 Appliance Document Number: 112 Version: 3.0 (10/03/15) Purpose This document describes the process for replacing a

More information

Installing the IPS 4345 and IPS 4360

Installing the IPS 4345 and IPS 4360 CHAPTER 4 Installing the IPS 4345 and IPS 4360 Contents This chapter describes the Cisco IPS 4345 and the IPS 4360, and includes the following sections: Installation Notes and Caveats, page 4-1 Product

More information

Veritas Appliance Hardware Service Procedure

Veritas Appliance Hardware Service Procedure Veritas Appliance Hardware Service Procedure Replacing a Disk Drive Carrier Document Number: 210 Version: 1.0 (11/06/17) Purpose This document describes the process for replacing a 4-TB/8-TB disk drive

More information

Chassis (FRU) Replacement Guide

Chassis (FRU) Replacement Guide SIEM9750 Release 1.0 Chassis (FRU) Replacement Guide Issue: 02 Date: 2011-11-07 Page 1 of 26 This document is intended for Symantec support personnel, IBM, or other authorized Symantec Service Partners.

More information

Supports up to four 3.5-inch SAS/SATA drives. Drive bays 1 and 2 support NVMe SSDs. A size-converter

Supports up to four 3.5-inch SAS/SATA drives. Drive bays 1 and 2 support NVMe SSDs. A size-converter , on page External Features, on page Serviceable Component Locations, on page Summary of Server Features, on page The server is orderable in different versions, each with a different front panel/drive-backplane

More information

EMC CloudArray. Customer Maintenance Guide REVISION 6.0

EMC CloudArray. Customer Maintenance Guide REVISION 6.0 EMC CloudArray Customer Maintenance Guide REVISION 6.0 Copyright 2015-2016 EMC Corporation. All rights reserved. Published in the USA. Published March, 2016 EMC believes the information in this publication

More information

Veritas Appliance Hardware Service Procedure

Veritas Appliance Hardware Service Procedure Veritas Appliance Hardware Service Procedure Replacing hard disk drives in a Primary Storage Shelf or an Expansion Storage Shelf Document Number: 137 Version: 3.2 (03/06/17) Purpose This document describes

More information

Juniper Secure Analytics Quick Start Guide

Juniper Secure Analytics Quick Start Guide Juniper Secure Analytics Quick Start Guide The instructions in this guide help you connect the Juniper Secure Analytics (JSA) appliance to your network. For details, see the JSA Hardware Guide at http://www.juniper.net/techpubs/en_us/release-independent/jsa/information-products/p

More information

Replacing an Advanced Power and Cooling (APC) Unit

Replacing an Advanced Power and Cooling (APC) Unit Replacing an Advanced Power and Cooling (APC) Unit You must replace a failed APC unit as quickly as possible (within minutes) to maintain correct airflow and cooling. Failed APC units can be hot-swapped.

More information

Dell SC7020 Storage Controller Getting Started Guide

Dell SC7020 Storage Controller Getting Started Guide Dell SC7020 Storage Controller Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better

More information

RM12_1394B. User Manual. Ver Date: 02/2006.

RM12_1394B. User Manual. Ver Date: 02/2006. RM12_1394B User Manual Ver 1.0 - Date: 02/2006 http://www.datoptic.com Copyright Notice The proprietary information contains in this document is protected by the copyright laws. All rights are reserved.

More information

High Density RocketRAID EJ6172 Device Board Data RAID Installation Guide

High Density RocketRAID EJ6172 Device Board Data RAID Installation Guide High Density RocketRAID 2711 + EJ6172 Device Board Data RAID Installation Guide Introduction The HighPoint High Density Storage Solutions hammer down high density storage cost over a single mini- SAS port.

More information

Install the Cisco DNA Center Appliance

Install the Cisco DNA Center Appliance About the Appliance Installation, page 1 Standalone Mode Requirements, page 3 Cisco DNA Center Appliance, page 3 Prepare for Appliance Installation, page 11 Connect and Power On the Appliance, page 14

More information

ReadyNAS OS 6 Desktop Storage Systems

ReadyNAS OS 6 Desktop Storage Systems ReadyNAS OS 6 Desktop Storage Systems Hardware Manual Models: 102 104 312 314 350 East Plumeria Drive San Jose, CA 95134 USA March 2013 202-11206-02 v1.0 Support Thank you for selecting NETGEAR products.

More information

HighPoint NA381TB3. 4U 24 bay ( 3.5" / 2.5" ) Thunderbolt 3 Storage and PCIe Expansion. User Manual

HighPoint NA381TB3. 4U 24 bay ( 3.5 / 2.5 ) Thunderbolt 3 Storage and PCIe Expansion. User Manual HighPoint NA381TB3 4U 24 bay ( 3.5" / 2.5" ) Thunderbolt 3 Storage and PCIe Expansion User Manual First edition, June. 2017 1. Overview 3 2. Package Checklist 3 3. Panel Layout 4 4. Hardware Configuration

More information

Front-loading drive bays 1 12 support 3.5-inch SAS/SATA drives. Optionally, front-loading drive bays 1 and 2 support 3.5-inch NVMe SSDs.

Front-loading drive bays 1 12 support 3.5-inch SAS/SATA drives. Optionally, front-loading drive bays 1 and 2 support 3.5-inch NVMe SSDs. , on page 1 External Features, on page 2 Serviceable Component Locations, on page 6 Summary of Server Features, on page 9 The server is orderable in different versions, each with a different front panel/drive-backplane

More information

Workstation Rack-Mount 4 RU Workstation, 4 RU Rack-Mount, Hexa-Core 3.5 GHz CPU, 16 GB DDR4 RAM, 256 GB SSD

Workstation Rack-Mount 4 RU Workstation, 4 RU Rack-Mount, Hexa-Core 3.5 GHz CPU, 16 GB DDR4 RAM, 256 GB SSD The is equipped with a powerful Intel Core i7 Hexa-Core CPU and 16 GB DDR4 RAM. Together with the included license for the Windows 10 operating system, it is an optimal and versatile platform for the use

More information

Customer Upgrade Procedure

Customer Upgrade Procedure Customer Upgrade Dell EMC Unity Family Dell EMC Unity All Flash and Unity Hybrid Adding an optional 80-drive DAE disk drive 302-003-780 REV 01 July 2017 This document describes how to add an optional 80-drive

More information

Install the Cisco DNA Center Appliance

Install the Cisco DNA Center Appliance About the Appliance Installation, page 1 Standalone Mode Requirements, page 2 Cisco DNA Center Appliance, page 3 Prepare for Appliance Installation, page 11 Connect and Power On the Appliance, page 14

More information

Dell EMC XC430 Xpress Hyper-converged Appliance. Service and Installation Manual

Dell EMC XC430 Xpress Hyper-converged Appliance. Service and Installation Manual Dell EMC XC430 Xpress Hyper-converged Appliance Service and Installation Manual Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product.

More information

Dell Storage MD1400 Enclosures Hardware Owner's Manual

Dell Storage MD1400 Enclosures Hardware Owner's Manual Dell Storage MD1400 Enclosures Hardware Owner's Manual Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates

More information

E-Series Hardware Cabling Guide

E-Series Hardware Cabling Guide E-Series Hardware Cabling Guide June 2017 215-11208_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 6 Cabling concepts and best practices... 7 Cabling concepts...

More information

Cisco UCS S3260 System Storage Management

Cisco UCS S3260 System Storage Management Storage Server Features and Components Overview, page 1 Cisco UCS S3260 Storage Management Operations, page 9 Disk Sharing for High Availability, page 10 Storage Enclosure Operations, page 15 Storage Server

More information

Data Sheet Fujitsu Server PRIMERGY CX400 M1 Compact and Easy

Data Sheet Fujitsu Server PRIMERGY CX400 M1 Compact and Easy Data Sheet Fujitsu Server Compact and Easy Data Sheet Fujitsu Server Compact and Easy Scale-Out Smart for HPC, Cloud and Hyper-Converged Computing The Fujitsu Server helps to meet the immense challenges

More information

NEC EXPRESS5800/R320b-M4 Configuration Guide

NEC EXPRESS5800/R320b-M4 Configuration Guide NEC EXPRESS5800/R320b-M4 Configuration Guide Linux model Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast

More information

Replacing a 3.5-inch disk drive

Replacing a 3.5-inch disk drive EMC VNXe Replacing a 3.5-inch disk drive 302-000-213 REV 02 July, 2015 This document describes how to replace a disk drive in a supported 12-slot disk enclosure: 12-slot disk processor enclosure (DPE)

More information

Cisco UCS S3260 System Storage Management

Cisco UCS S3260 System Storage Management Storage Server Features and Components Overview, page 1 Cisco UCS S3260 Storage Management Operations, page 9 Disk Sharing for High Availability, page 10 Storage Enclosure Operations, page 15 Storage Server

More information

Dell Storage Center. Owner's Manual. SC180 Expansion Enclosure. Regulatory Model: E11J Regulatory Type: E11J001

Dell Storage Center. Owner's Manual. SC180 Expansion Enclosure. Regulatory Model: E11J Regulatory Type: E11J001 Dell Storage Center SC180 Expansion Enclosure Owner's Manual Regulatory Model: E11J Regulatory Type: E11J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make

More information

3.5in esata USB Dual External Hard Drive Enclosure w/ SATA Controller

3.5in esata USB Dual External Hard Drive Enclosure w/ SATA Controller 3.5in esata USB Dual External Hard Drive Enclosure w/ SATA Controller Product ID: S352U2RERC StarTech.com's esata/usb External Dual SATA Hard Drive Enclosure offers hot-swappable installation of up to

More information

NEC EXPRESS5800/R320a-E4 Configuration Guide

NEC EXPRESS5800/R320a-E4 Configuration Guide NEC EXPRESS5800/R320a-E4 Configuration Guide Linux model Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast

More information

NEC Express5800/R120e-1M System Configuration Guide

NEC Express5800/R120e-1M System Configuration Guide NEC Express5800/R120e-1M System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

Customer Replacement Procedure

Customer Replacement Procedure Customer Replacement Dell EMC Unity Family Dell EMC Unity All Flash and Unity Hybrid Replacing a faulted 80-drive DAE cooling module 302-003-777 REV 01 July 2017 This document describes how to replace

More information

Cisco UCS C240 M3 NEBS High-Density Rack Server (Small Form Factor Disk Drive Model)

Cisco UCS C240 M3 NEBS High-Density Rack Server (Small Form Factor Disk Drive Model) Spec Sheet Cisco UCS C240 M3 NEBS High-Density Rack Server (Small Form Factor Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.1 MARCH 27, 2013 WWW.CISCO.COM

More information

Customer Replacement Procedure

Customer Replacement Procedure Customer Replacement EMC Unity Family EMC Unity Hybrid Replacing a faulted 3.5-inch disk drive 302-002-595 REV 01 May, 2016 This document describes how to replace a faulted 3.5-inch disk drive in the Unity

More information

Mediant Server Cloud Connector Edition

Mediant Server Cloud Connector Edition Hardware Installation Manual AudioCodes One Voice for Microsoft Skype for Business Mediant Server Cloud Connector Edition Cabling and Initial Configuration Version 1.0 Hardware Installation Manual Contents

More information

Teradata Integrated Big Data Platform Platform. Hardware Replacement Guide for Customers. February 2018 B K

Teradata Integrated Big Data Platform Platform. Hardware Replacement Guide for Customers. February 2018 B K Teradata Integrated Big Data Platform 1800 Platform Hardware Replacement February 2018 B0-602-06K Copyright and Trademarks Copyright 201-2018 by Teradata. All Rights Reserved. All copyrights and trademarks

More information

I/O Modules Overview. Before You Begin. I/O Module Options. ESD Requirements

I/O Modules Overview. Before You Begin. I/O Module Options. ESD Requirements I/O Modules Overview Use these instructions to set up the I/O modules supported in your TippingPoint security devices. Before You Begin Review the release notes for your product for any late-breaking changes

More information

Customer Replacement Procedure

Customer Replacement Procedure Customer Replacement EMC Unity Family EMC Unity All Flash and EMC Unity Hybrid Replacing a faulted 2.5-inch disk drive 302-002-594 REV 01 May, 2016 This document describes how to replace a faulted 2.5-inch

More information

Ollee Ultra Mini PC, a Mini PC with 32GB emmc and Windows 10 Pro MAPMG. Ollee Ultra Mini PC, a Mini PC with 120GB SSD and Windows 10 Pro MAPMG1

Ollee Ultra Mini PC, a Mini PC with 32GB emmc and Windows 10 Pro MAPMG. Ollee Ultra Mini PC, a Mini PC with 120GB SSD and Windows 10 Pro MAPMG1 Ollee Ultra Mini PC, a Mini PC with 32GB emmc and Windows 10 Pro MAPMG Ollee Ultra Mini PC, a Mini PC with 120GB SSD and Windows 10 Pro MAPMG1 User Guide Before You Begin CAUTIONS The procedures in this

More information

Customer Replacement Procedure

Customer Replacement Procedure Customer Replacement Procedure Dell EMC Unity Family Dell EMC Unity All Flash and Unity Hybrid Replacing a faulted 25-drive link control card 302-002-600 REV 02 July 2017 This document describes how to

More information

Atlas S8+ Product Manual. Version Promise Technology, Inc. All Rights Reserved.

Atlas S8+ Product Manual. Version Promise Technology, Inc. All Rights Reserved. Atlas S8+ Product Manual Version 1.0 2018 Promise Technology, Inc. All Rights Reserved. Promise Technology Atlas S8+ Copyright 2018 PROMISE Technology, Inc. All Rights Reserved. Important data protection

More information

3U 16-bay PCI-Express Rackmount JBOD Chassis. Installation Guide

3U 16-bay PCI-Express Rackmount JBOD Chassis. Installation Guide 3U 16-bay PCI-Express Rackmount JBOD Chassis Installation Guide Package Checklist Before installing this unit, verify that package contains the following items: Enclosure x 1 HDD Tray x 16 (Installed in

More information

emachines E627 Series Quick Guide

emachines E627 Series Quick Guide emachines E627 Series Quick Guide Copyright 2009. Acer Incorporated. All Rights Reserved. emachines E627 Series Quick Guide Original Issue: 06/2009 This company makes no representations or warranties,

More information

Appliance Comparison

Appliance Comparison Appliance Comparison 2003-2019 BeyondTrust Corporation. All Rights Reserved. BEYONDTRUST, its logo, and JUMP are trademarks of BeyondTrust Corporation. Other trademarks are the property of their respective

More information

M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions

M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions Part No. 530-003244-01 Revision 1 27 July 2000 This document describes how to remove and replace the AC and DC power supplies,

More information

Customer Upgrade Procedure

Customer Upgrade Procedure Customer Upgrade EMC Unity Family EMC Unity All Flash and EMC Unity Hybrid Adding an optional 2.5-inch disk drive 302-002-592 REV 01 May, 2016 This document describes how to add an optional 2.5-inch disk

More information

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions... Table of Contents Quick Install Guide page 1 EN English Table of Contents 1. Introduction... 2 1.1 Safety... 2 1.2 Rack System Precautions... 2-3 1.3 ESD Precautions... 3... 3 1... 3 2 Fitting PSU s...

More information

Manager Appliance Quick Start Guide

Manager Appliance Quick Start Guide Revision D Manager Appliance Quick Start Guide The Manager Appliance runs on a pre-installed, hardened McAfee Linux Operating System (MLOS) and comes pre-loaded with the Network Security Manager software.

More information

Cisco NAC Appliance Hardware Platforms

Cisco NAC Appliance Hardware Platforms 1 CHAPTER This chapter provides general information on the Cisco NAC Appliance network access control system, as well as hardware specifications for all Clean Access Manager (CAM) and Clean Access Server

More information

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2 Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.2 www.inxtron.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 Technical Specifications...

More information

Cisco UCS S3260 System Storage Management

Cisco UCS S3260 System Storage Management Storage Server Features and Components Overview, page 1 Cisco UCS S3260 Storage Management Operations, page 9 Disk Sharing for High Availability, page 10 Storage Enclosure Operations, page 17 Sas Expander

More information

Chenbro. ES34169 Chassis User s Manual. April / 2 /

Chenbro. ES34169 Chassis User s Manual. April / 2 / Chenbro ES34169 Chassis User Manual April / 2 / 2010 www.chenbro.com 1 Copyright Copyright 2007 Chenbro Micom Co., Ltd.. All rights reserved. Unless otherwise indicated, all materials in this manual are

More information

4 Bay esata USB 2.0 to SATA Hard Drive Docking Station for 2.5/3.5 HDD

4 Bay esata USB 2.0 to SATA Hard Drive Docking Station for 2.5/3.5 HDD 4 Bay esata USB 2.0 to SATA Hard Drive Docking Station for 2.5/3.5 HDD Product ID: SATDOCK4U2E The SATDOCK4U2E esata and USB 2.0 4-Bay SATA Hard Drive Docking Station is a convenient, timesaving storage

More information