1 DNS-2608 Enterprise JBOD Enclosure User Manual Nov.2017 Copyright DataON. All rights reserved.
2 1
3 Contents Package Contents... 3 System Requirements... 3 Technical Support... 3 DataON DNS-2608 Specifications... 4 System Front View and HDD Location... 5 LEDs on the Storage Enclosure... 6 Rear View... 7 SIM Board LED Descriptions... 8 PSM Board Descriptions System Fan and SSD Module Front Loading Carrier Rear Loading Carrier Install/Replace SAS Disk Power on the DNS Trademarks Disclaimer Safety Measures
4 Package Contents The DataON DNS-2608 Enterprise JBOD Enclosure box contains the following items: (1) DataON DNS-2608 storage appliance (2) Power cords for US customers only (1) CD with the user manual and drivers (1) Universal rail kit for the DNS (96) HDD screws System Requirements SFF-8644 to SFF Gbps SAS cable(s) For servers with supported HBA/RAID adapters, refer to the DNS-2608 support matrix for a complete list of supported adapters Technical Support Please visit our website at 3
5 DataON DNS-2608 Specifications Form Factor Drive Support Drive Form Factor 4U 32-bary 24x 3.5 (front) + 8x 2.5 (rear) 12Gb/s SAS 3.0 HDD and SDD (24) 3.5 /2.5 Hot-swappable 12Gb SAS drive tray with front access (8) 2.5 Hot-swappable 12Gb SAS drive tray I/O Controller Host Interface Controller Support Disk Drive Enclosure Cooling Power Supply (2) 12Gb/s SAS 3.0 (Avago SAS 3x48 expander) I/O modules (4) 12Gb/s Mini-SAS HD host ports via four SFF Gb/s HBAs and host-based RAID controller cards with external connectivity Hot-swap (32 bays) 2x 60mm fan for system + 2x 40mm fan for the SSD module Dual redundant power supply 2x 500W Platinum 110/220V AC LED Indicators *Identify enclosure *Power on & activity *Drive fault *Identify drive *Hot space *Drive rebuild *Power *I/O Module status *System Enclosure Dimensions Weight Operational Environment 7.56 H x 17.6 W x D 46.3lbs (enclosure only) Operating temperature 0 C to 40 C (32 F to 104 F) Non-operating temperature -40 C to 65 C (-40 F to 149 F) Operating relative humidity 20% to 85%RH. Non-operating relative humidity 10% to 90%RH 4
6 System Front View and HDD Location Number Component Description 1 Control panel The control panel includes the following LEDs and buttons: Power button with LED Status LED ID button ID LED 2 Thumb screw Secure the system to the rack. 3 Handle Hold with care and extend out the system from the rack when the rail kit is installed. The handle is not designed to carry this system. 4 Storage drive bay Houses the front-loading hot-plug 2.5 /3.5 SA/SATA HDDs/SSDs. 5
7 LEDs on the Storage Enclosure Number Component Color Lights On Lights Off 1 Power Green Power on Power off 2 Fault LED Amber Amber on: system failed* Normal Amber blinking (two times per second): rear SSD failed Amber blinking (four times per second): system failed + rear SSD failed* 3 Locate LED Flashing blue Identifies a storage enclosure. Normal 4 ID Button Press to toggle on/off the ID/LED 6
8 Rear View Important: Note the direction of the power supply unit. Insert the power supply with the right direction. All SAS port connectors are Mini-SAS HD (SFF-8644). 7
9 SIM Board LED Descriptions Number Component Color Lights On Lights Off 1 Service port Description: Mini-USB connector. Connects to local system for maintenance or debugging. 2 Mini-SAS HD ports Description: Mini-SAS HD connector. Connects to server system. Left ~ Right: Host 0 ~ Host 3: Host 0/3 for cascade in/out 3 Mini-SAS port status Amber Connection/PHY s link failed Status normal 4 Mini-SAS HD port activity LED Blue Connection established No connection 5 Link LED Amber Green Amber on: 1000Mbps connection Green on: 100Mbps connection Off: 10Mbps connection when activity LED blinking Off: Disconnected when activity LED off 6 Management port Manage the system from the remote connection through the GbE RJ45 management port for maintenance or debugging. 7 Activity LED Green Blinking: connected Disconnected 8
10 8 ID LED Flashing blue SIM identified Normal 9 Status LED Amber Failed Status good 10 Power LED Blue Power on Power off 9
11 PSM Board Descriptions Number Component Color Lights On Lights Off 1 Fan Cooling the power supply unit. 2 DC Power Green Amber Green: AC power on Green blinking (2/sec): Standby Green blinking (4/sec): Sleep mode Amber: Failed No AC power 3 Socket Connects to power cord. 4 Latch Press to release the latch. 5 Handle Pull out and hold the handle with hands for removing the PSU from the chassis bay. 10
12 System Fan and SSD Module Number Component Color Lights On Lights Off 1 Latch Press to release the latch of the SSD fan module. 2 Handle Pull out and hold the handle for removing the fan module from the chassis bay. 3 Fan LED Amber Failed Status good Note: To avoid system overheating, replace the fan module within 10 minutes. 11
13 Front Loading Carrier Number Component Color Lights On Lights Off 1 Handle Hold and pull the carrier out with care. The handle is not designed to carry the storage drive. 2 Release button Press to release the handle 3 Activity Blue Access active 4 Present/Fault Blue Present Slot empty Blinking blue, 2 per second Blinking blue, 1 per second Disk fault Rebuilding Slot empty Slot empty Amber Failed Slot empty 12
14 Rear Loading Carrier Number Component Color Lights On Lights Off 1 Handle Hold and pull the carrier out with care. The handle is not designed to carry the storage drive. SAS disk is ready 2 Release button Press to release the handle 3 Present/Fault Blue Present Slot empty Blinking blue, 2 per second Blinking blue, 1 per second Disk fault Rebuilding Slot empty Slot empty Amber Failed Slot empty 4 Activity Blue Access active 13
15 Install/Replace SAS Disk Before You Begin It is not recommended mixing different SAS SSDs and SAS HDDs in the same DNS-2608 system. If it is necessary, please use the following figures below to plan where you will be placing the disk drives. These figures represent a fully-loaded DNS-2608 system with SAS disks. However, the same guidelines apply even if you are filling some of the disk slots with blank disk trays in the mixing disk setting. Single-Zone Mode Single-zone mode has 4 mini-sas HD host post, 8 SSDs and 24 HDDs. Two-Zone Mode Two-zone mode has 2 mini-sas HD host posts, 4 SSDs and 12 HDDs as shown for each zone as shown. Note: SIM 1 does not support SATA device status. 14
16 Power on the DNS Verify that all connections are correct 2. Turn on both circuit breakers on the cabinet. 3. Make sure the power on LEDs on all DNS-2608 systems are steady blue. 4. Power on the host last. Please make sure to power on all DNS-2608 systems first before the server. 15
17 Trademarks DataON and the DataON logo, and MUST are trademarks of DataON in the United States. The following terms are trademarks of other companies: Intel, Xeon, and the Intel logo are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Active Directory, Hyper-V, Microsoft, SQL Server, Windows, Windows Server, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both. Other company, product, or service names may be trademarks or service marks of others. Disclaimer The information in this document is subject to change without notice. DataON makes no representations or warranties with respect to the contents hereof and specifically disclaim any implied warranties of merchantability or fitness for any particular purpose. DataON reserves the right to revise this publication and to make changes from time to time in the content without obligation to notify any person of such revision or changes. Safety Measures Computer components and electronic circuit boards can be damaged by discharges of static electricity. Working on computers that are still connected to a power supply can be extremely dangerous. Follow these guidelines to avoid damage to the DNS-2608 or injury to yourself. Always disconnect power when carrying out work inside the unit. If possible, wear a grounded wrist strap when carrying out work inside the unit. Alternatively, discharge and static by touching the bare metal chassis of the unit case, or the bare metal body of any other grounded appliance. Hold electronic circuit boards by the edges only. Do not touch the components on the board unless it is necessary to do so. Do not flex or stress the circuit board. Leave all components inside the static-proof packaging until you are ready to install the component. Version 2.0 / November
DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems.
DNS-2670 User Manual Version Dec. 2015 DataON Storage, storage division of Area Data Systems. Contents 1 Introduction... 1 1.1 System Overview... 3 1.1.1 System Top View...3 1.1.2 Front View...4 1.1.3
More informationETERNUS JX60. Technical Product Introduction. 0 Copyright Fujitsu, Release June 2014
0 Copyright Fujitsu, Release June 2014 Highlights The passive storage subsystem accommodates up to 240 HDDs 3.5" SAS 2.0 Nearline SAS 7200 rpm, max. storage capacity 960 TB 1) One or two 6 Gbit/s SAS interfaces
More informationDell SCv300 and SCv320 Expansion Enclosure Owner's Manual
Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual Regulatory Model: E03J, E04J Regulatory Type: E03J001, E04J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that
More informationSAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2
SAS to SAS/SATA JBOD Subsystem Revision 1.2 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Subsystem... 6 1.4 Identifying Parts
More informationSAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1
SAS to SAS/SATA JBOD Subsystem Revision 1.1 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Expansion Chassis... 6 1.4 Identifying
More informationDell EMC Storage MD1280 Enclosure Owner's Manual
Dell EMC Storage MD1280 Enclosure Owner's Manual Regulatory Model: SP-2584, E11J Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product.
More informationSAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1
SAS to SAS/SATA JBOD Subsystem Revision 1.1 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Expansion Chassis... 6 1.4 Identifying
More information64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0
64 Bays SAS to SAS/SATA JBOD Subsystem Revision 1.0 Table of Contents Preface... 4 Before You Begin... 5 Safety Guidelines... 5 Controller Configurations... 5 Packaging, Shipment and Delivery... 5 Unpacking
More informationVeritas Appliance Hardware Service Procedure
Veritas Appliance Hardware Service Procedure Replacing a RAID Controller in a Veritas 5U84 Primary Storage Shelf Document Number: 217 Version: 1.0 (11/06/17) Purpose This document describes the process
More informationSAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0
SAS to SAS/SATA JBOD Subsystem Revision 1.0 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Terminologies... 6 Chapter 2 Getting Started... 7 2.1 Unpacking
More informationDell SC5020 and SC5020F Storage System Owner s Manual
Dell SC5020 and SC5020F Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates
More informationDell SCv3000 and SCv3020 Storage System Owner s Manual
Dell SCv3000 and SCv3020 Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates
More informationDell SC7020 and SC7020F Storage Systems Owner s Manual
Dell SC7020 and SC7020F Storage Systems Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates
More informationSCv3000 and SCv3020 Storage System. Owner s Manual
SCv3000 and SCv3020 Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates
More informationSATA II HDD Canister KISS DA 435 Quick Reference Guide
SATA II HDD Canister KISS DA 435 Quick Reference Guide If it s embedded, it s Kontron 1. Table of Contents SATA II HDD Canister KISS DA 435 1. Table of Contents 1. Table of Contents... 1 2. Important Information...
More informationSAS JBOD Installation Reference Guide Revision 1.0
SAS JBOD 16-bay Rackmount Enclosure Installation Reference Guide Revision 1.0 P/N: PW0020000000281 Copyright No part of this publication may be reproduced, stored in a retrieval system, or transmitted
More informationapple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved.
apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May 2004 2003 Apple Computer, Inc. All rights reserved. apple Service Source Basics Xserve RAID 2003 Apple Computer, Inc.
More informationVeritas Appliance Hardware Service Procedure
Veritas Appliance Hardware Service Procedure I/O module replacement: Veritas 5240 Appliance Storage Shelf Document Number: 158 Version: 4.0 (7/04/16) Purpose This document describes the process for replacing
More informationDell MD1280 Storage Enclosure Getting Started Guide
Dell MD1280 Storage Enclosure Getting Started Guide Regulatory Model: SP-2584, E11J Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.
More information3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A
3-4 SAS/SATA II HDD Canister Entry version XC-34D1-SA10-0-R USER S MANUAL Document number: MAN-00077-A ii Preface Important Information Warranty Our product is warranted against defects in materials and
More informationapple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved.
apple Service Source Xserve RAID 17 March 2003 2003 Apple Computer, Inc. All rights reserved. apple Service Source Basics Xserve RAID 2003 Apple Computer, Inc. All rights reserved. Overview Xserve RAID
More informationTiger Box Expansion Chassis Assembly Guide
Tiger Box Expansion Chassis Assembly Guide Product Overview................................. 3 Tiger Box Expansion Chassis Features............... 3 Package Content............................. 4 Hardware
More informationVeritas Appliance Hardware Service Procedure
Veritas Appliance Hardware Service Procedure Replacing a SAS3 cable in a Veritas storage shelf Document Number: 166 Version: 4.1 (03/05/18) Purpose This document describes the process of replacing the
More informationSGI InfiniteStorage 120
SGI InfiniteStorage 120 Mass Storage Hardware Topics Edition 003 007-4853-003 Proprietary Rights Notices COPYRIGHT 2006, 2007 SGI. All rights reserved; provided portions may be copyright in third parties,
More informationSerial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E
Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Order Number:
More informationInstalling the Cisco ADE 2130 and 2140 Series Appliance Hardware Options
CHAPTER 4 Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options This chapter provides instructions for installing, replacing, and removing various hardware options in your Cisco ADE
More informationRocsecure NE52 NAS System
Rocsecure NE52 NAS System Revision 1.0 Table of Contents Preface... 3 Before You Begin... 4 Safety Guidelines... 4 Packaging, Shipment and Delivery... 4 Chapter 1 Introduction... 5 1.1 Key Features...
More informationDell EMC ME4 Series JBOD 5U84 Enclosure
Dell EMC ME4 Series JBOD 5U84 Enclosure Deployment Guide Regulatory Model: E09J, E10J, E11J Regulatory Type: E09J001, E10J001, E11J001 Notes, cautions, and warnings NOTE: A NOTE indicates important information
More informationDell SC460 Expansion Enclosure Getting Started Guide
Dell SC460 Expansion Enclosure Getting Started Guide Regulatory Model: CYAE Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION:
More informationHP ProLiant DL165 G7 Server
HP ProLiant DL165 G7 Server Installation Instructions Part Number 601464-003 Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 LFF HDD Item Description 1 Thumbscrews
More informationHP ProLiant SL160z G6 Server
HP ProLiant SL160z G6 Server Installation Instructions Part Number 571291-004 Item Description 7 UID LED/SW 8 PCI Slot 9 Health LED 10 Power Button Rear Panel Components Figure 2 Rear panel components
More informationVeritas Appliance Hardware Service Procedure
Veritas Appliance Hardware Service Procedure Operating system disk drive and log disk drive replacement - NetBackup 0 Appliance Document Number: 7 Version:.0 (7/0/6) Purpose This document describes the
More informationSCv360 Expansion Enclosure
SCv360 Expansion Enclosure Getting Started Guide Regulatory Model: CYAE Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION:
More informationXTM 1050 Replacement Parts Installation
XTM 1050 Replacement Parts Installation Instructions to replace or install: Power Supply Chassis Fan Fiber Card 10 Gb Interface Module WARNING! Do not open the XTM 1050 or try to replace or install any
More informationiosafe BDR515 Hardware Guide
iosafe BDR515 Hardware Guide 910-11762-00 Rev03 HARDWARE GUIDE, BDR515 Table of Contents Chapter 1: Before You Start Package Contents... 3 iosafe at a Glance... 4 Safety Instructions... 5 Chapter 2: Hardware
More informationiosafe SERVER 5 Quick Start Guide
iosafe SERVER 5 Quick Start Guide 910-11782-00 Rev02 QUICKSTART GUIDE, SERVER 5 Table of Contents Chapter 1: Before You Start Package Contents... 3 iosafe at a Glance... 4 Safety Instructions... 5 Chapter
More informationNext Generation Firewall
Next Generation Firewall Hardware Guide Model 6205 Revision C Contents Introduction on page 2 Find product documentation on page 2 Model 6205 features on page 3 Supported interface modules on page 6 Precautions
More informationCustomer Replacement Procedure
Customer Replacement Procedure Dell EMC Unity Family Dell EMC Unity All Flash and Unity Hybrid Replacing a faulted 25-drive DAE power supply and cooling module 302-002-598 REV 02 September 2017 This document
More informationNAS System. User s Manual. Revision 1.0
User s Manual Revision 1.0 Before You Begin efore going through with this manual, you should read and focus on the following safety guidelines. Information about the NAS system s packaging and delivery
More informationDell SCv3000 and SCv3020 Storage System Getting Started Guide
Dell SCv3000 and SCv3020 Storage System Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make
More information1U Device Expansion Unit Configuration Guide
1U Device Expansion Unit Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper
More informationJanusRAID SA-6692J Hardware User Manual
JanusRAID SA-6692J Hardware User Manual 42-30000-5067 SATA II JBOD enclosure Version 1.1 SA-6692J SATA II JBOD enclosure Hardware User Manual Table of Contents Preface... i Chapter 1 System Requirements
More informationDell SC5020 and SC5020F Storage Systems Getting Started Guide
Dell SC5020 and SC5020F Storage Systems Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make
More informationNT2 U3. 2-Bay RAID Storage Enclosure. User Manual May 18, 2010 v1.1
2-Bay RAID Storage Enclosure User Manual May 18, 2010 v1.1 EN Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III CPU 500MHz, 128MB RAM Windows Vista, Windows
More informationDell PowerVault MD3060e Storage Enclosure Owner's Manual
Dell PowerVault MD3060e Storage Enclosure Owner's Manual Regulatory Model: E08J Series Regulatory Type: E08J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you
More informationNext Generation Firewall
Next Generation Firewall Hardware Guide Model 6205 Revision A Contents Introduction on page 2 Find product documentation on page 2 Model 6205 features on page 3 Supported interface modules on page 6 Precautions
More informationData Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure
Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure Scale-Out Smart for HPC and Cloud Computing with enhanced
More informationVeritas Appliance Hardware Service Procedure
Veritas Appliance Hardware Service Procedure Power Supply Replacement: NetBackup 5220 Appliance Document Number: 112 Version: 3.0 (10/03/15) Purpose This document describes the process for replacing a
More informationInstalling the IPS 4345 and IPS 4360
CHAPTER 4 Installing the IPS 4345 and IPS 4360 Contents This chapter describes the Cisco IPS 4345 and the IPS 4360, and includes the following sections: Installation Notes and Caveats, page 4-1 Product
More informationVeritas Appliance Hardware Service Procedure
Veritas Appliance Hardware Service Procedure Replacing a Disk Drive Carrier Document Number: 210 Version: 1.0 (11/06/17) Purpose This document describes the process for replacing a 4-TB/8-TB disk drive
More informationChassis (FRU) Replacement Guide
SIEM9750 Release 1.0 Chassis (FRU) Replacement Guide Issue: 02 Date: 2011-11-07 Page 1 of 26 This document is intended for Symantec support personnel, IBM, or other authorized Symantec Service Partners.
More informationSupports up to four 3.5-inch SAS/SATA drives. Drive bays 1 and 2 support NVMe SSDs. A size-converter
, on page External Features, on page Serviceable Component Locations, on page Summary of Server Features, on page The server is orderable in different versions, each with a different front panel/drive-backplane
More informationEMC CloudArray. Customer Maintenance Guide REVISION 6.0
EMC CloudArray Customer Maintenance Guide REVISION 6.0 Copyright 2015-2016 EMC Corporation. All rights reserved. Published in the USA. Published March, 2016 EMC believes the information in this publication
More informationVeritas Appliance Hardware Service Procedure
Veritas Appliance Hardware Service Procedure Replacing hard disk drives in a Primary Storage Shelf or an Expansion Storage Shelf Document Number: 137 Version: 3.2 (03/06/17) Purpose This document describes
More informationJuniper Secure Analytics Quick Start Guide
Juniper Secure Analytics Quick Start Guide The instructions in this guide help you connect the Juniper Secure Analytics (JSA) appliance to your network. For details, see the JSA Hardware Guide at http://www.juniper.net/techpubs/en_us/release-independent/jsa/information-products/p
More informationReplacing an Advanced Power and Cooling (APC) Unit
Replacing an Advanced Power and Cooling (APC) Unit You must replace a failed APC unit as quickly as possible (within minutes) to maintain correct airflow and cooling. Failed APC units can be hot-swapped.
More informationDell SC7020 Storage Controller Getting Started Guide
Dell SC7020 Storage Controller Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better
More informationRM12_1394B. User Manual. Ver Date: 02/2006.
RM12_1394B User Manual Ver 1.0 - Date: 02/2006 http://www.datoptic.com Copyright Notice The proprietary information contains in this document is protected by the copyright laws. All rights are reserved.
More informationHigh Density RocketRAID EJ6172 Device Board Data RAID Installation Guide
High Density RocketRAID 2711 + EJ6172 Device Board Data RAID Installation Guide Introduction The HighPoint High Density Storage Solutions hammer down high density storage cost over a single mini- SAS port.
More informationInstall the Cisco DNA Center Appliance
About the Appliance Installation, page 1 Standalone Mode Requirements, page 3 Cisco DNA Center Appliance, page 3 Prepare for Appliance Installation, page 11 Connect and Power On the Appliance, page 14
More informationReadyNAS OS 6 Desktop Storage Systems
ReadyNAS OS 6 Desktop Storage Systems Hardware Manual Models: 102 104 312 314 350 East Plumeria Drive San Jose, CA 95134 USA March 2013 202-11206-02 v1.0 Support Thank you for selecting NETGEAR products.
More informationHighPoint NA381TB3. 4U 24 bay ( 3.5" / 2.5" ) Thunderbolt 3 Storage and PCIe Expansion. User Manual
HighPoint NA381TB3 4U 24 bay ( 3.5" / 2.5" ) Thunderbolt 3 Storage and PCIe Expansion User Manual First edition, June. 2017 1. Overview 3 2. Package Checklist 3 3. Panel Layout 4 4. Hardware Configuration
More informationFront-loading drive bays 1 12 support 3.5-inch SAS/SATA drives. Optionally, front-loading drive bays 1 and 2 support 3.5-inch NVMe SSDs.
, on page 1 External Features, on page 2 Serviceable Component Locations, on page 6 Summary of Server Features, on page 9 The server is orderable in different versions, each with a different front panel/drive-backplane
More informationWorkstation Rack-Mount 4 RU Workstation, 4 RU Rack-Mount, Hexa-Core 3.5 GHz CPU, 16 GB DDR4 RAM, 256 GB SSD
The is equipped with a powerful Intel Core i7 Hexa-Core CPU and 16 GB DDR4 RAM. Together with the included license for the Windows 10 operating system, it is an optimal and versatile platform for the use
More informationCustomer Upgrade Procedure
Customer Upgrade Dell EMC Unity Family Dell EMC Unity All Flash and Unity Hybrid Adding an optional 80-drive DAE disk drive 302-003-780 REV 01 July 2017 This document describes how to add an optional 80-drive
More informationInstall the Cisco DNA Center Appliance
About the Appliance Installation, page 1 Standalone Mode Requirements, page 2 Cisco DNA Center Appliance, page 3 Prepare for Appliance Installation, page 11 Connect and Power On the Appliance, page 14
More informationDell EMC XC430 Xpress Hyper-converged Appliance. Service and Installation Manual
Dell EMC XC430 Xpress Hyper-converged Appliance Service and Installation Manual Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product.
More informationDell Storage MD1400 Enclosures Hardware Owner's Manual
Dell Storage MD1400 Enclosures Hardware Owner's Manual Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates
More informationE-Series Hardware Cabling Guide
E-Series Hardware Cabling Guide June 2017 215-11208_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 6 Cabling concepts and best practices... 7 Cabling concepts...
More informationCisco UCS S3260 System Storage Management
Storage Server Features and Components Overview, page 1 Cisco UCS S3260 Storage Management Operations, page 9 Disk Sharing for High Availability, page 10 Storage Enclosure Operations, page 15 Storage Server
More informationData Sheet Fujitsu Server PRIMERGY CX400 M1 Compact and Easy
Data Sheet Fujitsu Server Compact and Easy Data Sheet Fujitsu Server Compact and Easy Scale-Out Smart for HPC, Cloud and Hyper-Converged Computing The Fujitsu Server helps to meet the immense challenges
More informationNEC EXPRESS5800/R320b-M4 Configuration Guide
NEC EXPRESS5800/R320b-M4 Configuration Guide Linux model Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast
More informationReplacing a 3.5-inch disk drive
EMC VNXe Replacing a 3.5-inch disk drive 302-000-213 REV 02 July, 2015 This document describes how to replace a disk drive in a supported 12-slot disk enclosure: 12-slot disk processor enclosure (DPE)
More informationCisco UCS S3260 System Storage Management
Storage Server Features and Components Overview, page 1 Cisco UCS S3260 Storage Management Operations, page 9 Disk Sharing for High Availability, page 10 Storage Enclosure Operations, page 15 Storage Server
More informationDell Storage Center. Owner's Manual. SC180 Expansion Enclosure. Regulatory Model: E11J Regulatory Type: E11J001
Dell Storage Center SC180 Expansion Enclosure Owner's Manual Regulatory Model: E11J Regulatory Type: E11J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make
More information3.5in esata USB Dual External Hard Drive Enclosure w/ SATA Controller
3.5in esata USB Dual External Hard Drive Enclosure w/ SATA Controller Product ID: S352U2RERC StarTech.com's esata/usb External Dual SATA Hard Drive Enclosure offers hot-swappable installation of up to
More informationNEC EXPRESS5800/R320a-E4 Configuration Guide
NEC EXPRESS5800/R320a-E4 Configuration Guide Linux model Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast
More informationNEC Express5800/R120e-1M System Configuration Guide
NEC Express5800/R120e-1M System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and
More informationCustomer Replacement Procedure
Customer Replacement Dell EMC Unity Family Dell EMC Unity All Flash and Unity Hybrid Replacing a faulted 80-drive DAE cooling module 302-003-777 REV 01 July 2017 This document describes how to replace
More informationCisco UCS C240 M3 NEBS High-Density Rack Server (Small Form Factor Disk Drive Model)
Spec Sheet Cisco UCS C240 M3 NEBS High-Density Rack Server (Small Form Factor Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.1 MARCH 27, 2013 WWW.CISCO.COM
More informationCustomer Replacement Procedure
Customer Replacement EMC Unity Family EMC Unity Hybrid Replacing a faulted 3.5-inch disk drive 302-002-595 REV 01 May, 2016 This document describes how to replace a faulted 3.5-inch disk drive in the Unity
More informationMediant Server Cloud Connector Edition
Hardware Installation Manual AudioCodes One Voice for Microsoft Skype for Business Mediant Server Cloud Connector Edition Cabling and Initial Configuration Version 1.0 Hardware Installation Manual Contents
More informationTeradata Integrated Big Data Platform Platform. Hardware Replacement Guide for Customers. February 2018 B K
Teradata Integrated Big Data Platform 1800 Platform Hardware Replacement February 2018 B0-602-06K Copyright and Trademarks Copyright 201-2018 by Teradata. All Rights Reserved. All copyrights and trademarks
More informationI/O Modules Overview. Before You Begin. I/O Module Options. ESD Requirements
I/O Modules Overview Use these instructions to set up the I/O modules supported in your TippingPoint security devices. Before You Begin Review the release notes for your product for any late-breaking changes
More informationCustomer Replacement Procedure
Customer Replacement EMC Unity Family EMC Unity All Flash and EMC Unity Hybrid Replacing a faulted 2.5-inch disk drive 302-002-594 REV 01 May, 2016 This document describes how to replace a faulted 2.5-inch
More informationOllee Ultra Mini PC, a Mini PC with 32GB emmc and Windows 10 Pro MAPMG. Ollee Ultra Mini PC, a Mini PC with 120GB SSD and Windows 10 Pro MAPMG1
Ollee Ultra Mini PC, a Mini PC with 32GB emmc and Windows 10 Pro MAPMG Ollee Ultra Mini PC, a Mini PC with 120GB SSD and Windows 10 Pro MAPMG1 User Guide Before You Begin CAUTIONS The procedures in this
More informationCustomer Replacement Procedure
Customer Replacement Procedure Dell EMC Unity Family Dell EMC Unity All Flash and Unity Hybrid Replacing a faulted 25-drive link control card 302-002-600 REV 02 July 2017 This document describes how to
More informationAtlas S8+ Product Manual. Version Promise Technology, Inc. All Rights Reserved.
Atlas S8+ Product Manual Version 1.0 2018 Promise Technology, Inc. All Rights Reserved. Promise Technology Atlas S8+ Copyright 2018 PROMISE Technology, Inc. All Rights Reserved. Important data protection
More information3U 16-bay PCI-Express Rackmount JBOD Chassis. Installation Guide
3U 16-bay PCI-Express Rackmount JBOD Chassis Installation Guide Package Checklist Before installing this unit, verify that package contains the following items: Enclosure x 1 HDD Tray x 16 (Installed in
More informationemachines E627 Series Quick Guide
emachines E627 Series Quick Guide Copyright 2009. Acer Incorporated. All Rights Reserved. emachines E627 Series Quick Guide Original Issue: 06/2009 This company makes no representations or warranties,
More informationAppliance Comparison
Appliance Comparison 2003-2019 BeyondTrust Corporation. All Rights Reserved. BEYONDTRUST, its logo, and JUMP are trademarks of BeyondTrust Corporation. Other trademarks are the property of their respective
More informationM5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions
M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions Part No. 530-003244-01 Revision 1 27 July 2000 This document describes how to remove and replace the AC and DC power supplies,
More informationCustomer Upgrade Procedure
Customer Upgrade EMC Unity Family EMC Unity All Flash and EMC Unity Hybrid Adding an optional 2.5-inch disk drive 302-002-592 REV 01 May, 2016 This document describes how to add an optional 2.5-inch disk
More informationTable of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...
Table of Contents Quick Install Guide page 1 EN English Table of Contents 1. Introduction... 2 1.1 Safety... 2 1.2 Rack System Precautions... 2-3 1.3 ESD Precautions... 3... 3 1... 3 2 Fitting PSU s...
More informationManager Appliance Quick Start Guide
Revision D Manager Appliance Quick Start Guide The Manager Appliance runs on a pre-installed, hardened McAfee Linux Operating System (MLOS) and comes pre-loaded with the Network Security Manager software.
More informationCisco NAC Appliance Hardware Platforms
1 CHAPTER This chapter provides general information on the Cisco NAC Appliance network access control system, as well as hardware specifications for all Clean Access Manager (CAM) and Clean Access Server
More informationTaurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2
Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.2 www.inxtron.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 Technical Specifications...
More informationCisco UCS S3260 System Storage Management
Storage Server Features and Components Overview, page 1 Cisco UCS S3260 Storage Management Operations, page 9 Disk Sharing for High Availability, page 10 Storage Enclosure Operations, page 17 Sas Expander
More informationChenbro. ES34169 Chassis User s Manual. April / 2 /
Chenbro ES34169 Chassis User Manual April / 2 / 2010 www.chenbro.com 1 Copyright Copyright 2007 Chenbro Micom Co., Ltd.. All rights reserved. Unless otherwise indicated, all materials in this manual are
More information4 Bay esata USB 2.0 to SATA Hard Drive Docking Station for 2.5/3.5 HDD
4 Bay esata USB 2.0 to SATA Hard Drive Docking Station for 2.5/3.5 HDD Product ID: SATDOCK4U2E The SATDOCK4U2E esata and USB 2.0 4-Bay SATA Hard Drive Docking Station is a convenient, timesaving storage
More information