icp 1000 Wireless GSM Based Remote Monitoring Unit for Transformer Rectifier Unit
|
|
- Avice Hensley
- 5 years ago
- Views:
Transcription
1 icp 1000 Wireless GSM Based Remote Monitoring Unit for Transformer Rectifier Unit
2 The GSM based remote monitoring unit icp 1000, for Transformer Rectifier (TR) monitoring, is a highly accurate, compact, low power, low cost, micro controller based unit with built in GSM Modem which enables continuous Centralized Monitoring of TR parameters and at the same time notification for any alarm occurrence at central station as well on the configured cell numbers. This system enables easy & wireless centralized monitoring of all TR parameters like TR Voltage, TR Current, and Reference Potential and A.C Interference voltage (optional). The icp 1000 can be installed in the existing TR Unit and can directly accept TR parameters without the need of any transducers. The icp 1000 acquires all analog and digital parameters and transmits it to the central station at the programmed periodic interval. The icp 1000 notifies the user for the occurrence of any alarm signal and gives the data to the central station irrespective of the periodic interval. At the remote end, the Data could be received using a GSM interface module connected to the PC installed with the CP Software REMOTE DATA. Remote Data displays the data in the Analytical and graphical format and stores this data in the standard database, which is used for generating, reports for further analysis of the structure under protection. The data broadcast schedule is fully programmable from 1 broadcast per Minute to one broadcast per day.
3 Apart from sending the TR data to the remote stations, this unit also Logs data in its Non Volatile memory at the programmed logging interval, thus it also is a data logger. It can store about 7000 readings which can be downloaded on the Laptop computer using a RS232 port provided on the unit. The data stored in the internal memory can retain for 10 years without any external power. The detailed technical specifications of the unit are as under: Unit : icp 1000i / icp 1000iAC : Micro controller based intelligent TR Monitoring Unit with built in GSM Modem. SPECIFICATIONS Analog Inputs Computed Inputs : High accuracy, High Input Impedance > 10Mohms, 16 bit resolution, Differential Input with high common mode rejection ratio CMRR. CH 1: VDC (for TR output DC Voltage) CH 2: mv (for TR Output Current) CH 3: 4V to +4 V DC (for Reference potential) CH 4: 0 300VAC ( Through power supply inputs) : Apart from the acquiring the physical Analog signal, the icp 1000 also Computes for TR Run hours. It samples and logs the TR Input AC power every minute and computes for the TR Run hours. This Reading is used by Remote Data Software to generate the Up Time Report of the TR Unit. The icp 1000 also continuously scans and checks for Alarm conditions listed below on the basis of Reference potential Over Protection Under Protection Reference Fail The Set parameters for the above alarm conditions can be feed through the local keypad available on the front panel of the icp Status Inputs : Pre Programmed Alarms Indication for the below conditions DI 1: Over Protection. DI 2: Under Protection. DI 3: Reference Fail DI 4: Door Open Alarm GSM Interface Built In GSM Modem for broadcasting data to the Central Station at the programmed periodic interval. The Data are transmitted in the form of SMS.
4 Alarm Notification The icp 1000 will notify to all the configured cell numbers on their cell phone along with sending the notification to the central stations. Over Protection. Under Protection. Reference Fail Door Open Alarm AC Input Power Fail Centralised Monitoring The icp 1000 has built in GSM modem to communicate with the central station over the GSM network. The icp 1000, send the TR Data with exact time stamp to the central station at the programmed Periodic Interval. At the central end the PC is installed with the GSM module and centralized monitoring software Remote Data. The icp 1000 sends alarm information with exact time stamp to the central station and the configured cell numbers, irrespective of the Periodic Interval. Remote Data accepts the data received from the icp 1000, displays them in graphical and analytical formats and stores them in database to generate Reports and Graphs. It is also possible to send configuration details like Setting Data/Time, Setting/ changing Periodic Interval and Setting of cell phone numbers for getting Alarm notifications. Local Keypad & Display The icp 1000 consists of a 3 x 6 matrix membrane keypad and a 16 x 2 LCD with back lit for entering local settings and viewing TR parameters locally. Local settings such as Setting Data/ Time Setting Start Time for Periodic sending of data to the Central station. Setting Periodic Interval Scaling Entering cell numbers for alarm notifications. Setting ID of the icp Can be done using local keypad and LCD. The LCD will normally display TR Voltage TR Current Reference Potential TR Run Hours GSM Signal Strength GSM SIM registrations. The icp 1000 can also be remotely configured for some of the above parameters from the central station.
5 Programmable Periodic Interval Data Storage Time Stamping Protection Enclosure Ingress Protection Power Supply Battery Back UP Temperature Environment Test The Periodic interval can be programmable from 1 broadcast /Hour to broadcast / 24 hours. Data can be stored in the non volatile Memory. About 7000 readings can be stored without downloading. Local Data retention up to 10 years without any external power. The Logged Data in the icp 1000 can be downloaded on the Notebook computer using the serial communication port provided on the front panel of the icp The icp 1000 is supplied with Data downloading software LogData. LogData downloaded the Data and generates Reports and Graphs. The Unit has precise, accurate Real Time Clock (RTC) for exact time stamping of data. The Input channels have full protection against high voltage surges and continuous over voltages. The Enclosure is of ABS material and has an ingress protections level of IP54. The power supply of the icp 1000 can accept below both voltage ranges 120 VAC to 320 VAC For 4 Hours on AC Power failure. With Battery recharging and Deep discharge protection circuit. 20 degree C to 55 degree C and humidity of 95% (RH) 1> IEC Dry Heat ( ) 2> IEC Damp Heat Steady State ( ) 3> IEC Damp Heat Cyclic ( ) 4> IEC Cold Test ( ) Size Serial Port Cable Entry Compact size. Can be easily installed in the standard TR Units 200 x 120 x 100 (mm) The Unit has a RS232 port through which the logged data can be downloaded onto the laptop. Bottom
Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types
Millenium 3 General Characteristics Millenium 3 Compact Range Millenium 3 Expandable Range Millenium 3 Communication Options Millenium 3 Range General environment characteristics for CB, CD, XD, XR and
More informationGS828. GPRS Data Logger
Sirius Corp GPRS Data Logger Multi Channels Data Logging & Wireless Transmission Upload Data via GPRS and SMS on schedule or alarm triggered Programmable data logging and upload interval Support sensors
More informationGS828-H. GPRS Data Logger
GPRS Data Logger GS828-H Multi Channels Data Logging & Wireless Transmission Upload Data via GPRS and SMS on schedule or alarm triggered Programmable data logging and upload interval Support sensors via
More information1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...
.6 Contents Standards and Certifications............... Product Selection....................... Technical Data and Specifications........... Dimensions............................ Learn Online Page V3-T-04
More informationIP68. Autarkic Data Loggers - MT-051 / MT-713 / MT-723
Autarkic Data Loggers - MT-051 / MT-713 / MT-723 Use in the most demanding environments These data loggers are designed for use in difficult to reach and widely distributed locations. In places where neither
More informationNX21 USER MANUAL. Telemetry Unit. Version 1.5
USER MANUAL Version 1.5 Nortech Management Ltd, United Kingdom NOV 2016 www.nortechonline.co.uk Doc Ref D_000344 Publication Notice Copyright Nortech Management Limited (NML). All rights reserved. No part
More informationALMEMO 202 ALMEMO professional measuring instrument, latest V7 generation with data logger function. ALMEMO V7 Measuring Instrument
ALMEMO V7 Measuring Instrument ALMEMO 202 ALMEMO professional measuring instrument, latest V7 generation with data logger function. Two measuring inputs for all digital ALMEMO D7 sensors. Special functions
More informationTemperature / Humidity Controller for Stability Chamber
Temperature / Humidity Controller for Stability Chamber Model Wise Description: Sr. No Model Product Description 14.2.4 HTC-3003 Microcontroller based Temperature & %RH PID-On/Off controller (2 AI + 2
More informationTesting Instruments Manufactured by
Circuit Breaker Dynamic Contact Resistance Meter HISAC Ultima Circuit Breaker Dynamic Test Set with up to Six Channel Dynamic Contact Resistance Meter 24 Binary Channels (4 Main + 4 PIR per Pole, 3 Poles
More informationRCW-400A USER GUIDE. Version 1.1
RCW-400A USER GUIDE Version 1.1 User Guide Chapter I Product Introduction1 1.1 Overview 1.2 Features and functions Chapter II Instructions for Use 2.1 Product Display 2.1.1 Interface 2.1.2 LCD display
More information1. Chapter 1 24/48/110/220VDC Power Supply System
1. Chapter 1 24/48/110/220VDC Power Supply System A. Outline of 24/48/110/220VDC Power Supply System Picture Picture 2*Rectifier module 3*Rectifier module 6*Rectifier module 10*Rectifier module Rectifier
More informationIDM DATA ACQUISITION SYSTEM
DATA ACQUISITION SYSTEM The a compact and economical multifunction data acquisition system Rendering all Unrivalled product profile Advanced multifunctional distributed data acquisition system Fully multitasking
More informationVaisala Veriteq VL 2000 Temperature Humidity Loggers
Vaisala Veriteq VL 2000 Temperature Humidity Loggers Vaisala s Veriteq VL 2000 series loggers are fully validatable and designed for regulated industries/pharmaceutical applications with NIST-traceable,
More informationNI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server
DATALOGGER NI2400/NI816/NI4866 8/16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATASHEET Rev. 08 del 08/10/2018 Redatto da R&D Approvato da MKT GENERAL 1SPECIFICATIONS NI4866 NI816 NI2400
More informationType VRLTC tap changer
Report No. 1ZUA938502-AGC 2, Rev 0 Date: 6 November 2012 Type VRLTC tap changer Ruggedized electronics systems specification & type test data Product Style No Rating By Type VRLTC, on-tank, vacuum reactance
More informationMINER-S Station Controller. Substation Automation
Substation Automation MINER-S Station Controller incorporates traditional RTU functions with new technology in a compact design MINER-S Station Controller combines the functions of a traditional RTU with
More informationDupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications
Dupline Data Logger Types G 800 006, G 800 106 Product Description Programmable channel generator with optional built-in GSM Modem Event and time based data logging functions for digital, analog and counter
More informationTechnical specifications
Technical specifications General information Operating temperature -25 to 60 C Storage temperature -40 to 70 C Enclosure type Panel installation (DIN IEC 61554) Enclosure fixing Screw-type clamping technology
More informationMINER-S Station Controller
MINER-S Station Controller Substation Automation MINER-S Station Controller The MINER-S Station Controller is a SCADA enabled fixed point remote terminal unit (RTU) with a data concentrator, event reporter,
More informationInternational Journal of Scientific & Engineering Research, Volume 8, Issue 4, April ISSN
International Journal of Scientific & Engineering Research, Volume 8, Issue 4, April-2017 372 REMOTE ALERT SYSTEM FOR ELECTRICITY IN PLUG MAINS Kenechukwu Anolue, Chijioke Ani Abstract: The research was
More informationMW/MVAR Transducer Specifications
GUARANTEED TECHNICAL PARTICULARS (To be submitted by bidder with the tender) MW/MVAR Transducer Specifications Sr.No. Descriptions Details Offered by supplier 1 2 3 4 Transducer suitable for Input Output
More informationAndover ContinuumTM Infinet II
Andover ContinuumTM Infinet II i2920 System Controllers The Andover Continuum Infinet II i2920 System Controller is designed to meet the needs of your most demanding control and monitoring applications
More informationEM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter
TOU SMART ENERGY METER SATEC is a Smart DIN Rail TOU Energy Meter. It is based on SATEC s best seller PM130 PLUS with an off-theshelf LCD display (similar to the BFM136 display). The provides the full
More informationUser Manual. GSM Fixed Wireless Phone (Model: GSM-938) Introduction
User Manual Introduction The latest style desktop wireless telecommunication products. It can send wireless SMS and voice at anytime, anywhere, suitable remote countries or mountains. Please take care
More informationMehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording
Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording Two independent, simultaneously operating recorders in one package Triggering on input quantities and calculated values, such as
More informationHYBRID PV INVERTERS HySpirit Series. 4kW-10kW. Hybrid Inverter with Battery Backup Smart Energy for Smart Home
HYBRID PV INVERTERS HySpirit Series Hybrid Inverter with Battery Backup Smart Energy for Smart Home 4kW-10kW FSP HySpirit series Offers a more intelligent power solution for our customers to reduce the
More informationFCU (FREE COOLING UNIT)
FCU (FREE COOLING UNIT) FCU reduces the AC running hours on the telecom site Controller Features: Can control upto two AC and one free cooling unit Temperature control Humidity sensor Structural Features:
More informationCommuni-Cell Communicator Nokia Version
Communi-Cell Communicator Nokia Version Jan 2007 Instruction Manual 1 ABOUT THE COMMUNI-CELL COMMUNICATOR SYSTEM The Communi-Cell Communicator system is based on GSM SMS technology. It uses a standard
More informationAndover ContinuumTM Infinet II
Andover ContinuumTM Infinet II The i80 Series controllers are designed for control of Air Handling Units, Roof Top Units, and other mechanical plant equipment. Features 0 Choose the i80 model with the
More information6220 Ethernet-Based Voltage Measurement Module
6220 Ethernet-Based Voltage Measurement Module Features 12 voltage inputs 16-bit, 100-kHz per channel sample rate ±10V input range Eight digital I/O Simultaneous sampling BNC connectors Multiple trigger
More informationAUTOMATIC AND AUTONOMOUS REMOTE WATER LEVEL AND WATER QUALITY MONITORING STATION
Brochure nº 9722.0048 AUTOMATIC AND AUTONOMOUS REMOTE WATER LEVEL AND WATER QUALITY MONITORING STATION MODEL HYDRODATA-2000C SERIES GEONICA, S.A. - Alejandro Rodríguez, nº 22-28039 Madrid - Spain Tel.
More informationData logger systems from ROTRONIC
Data logger systems from ROTRONIC RS-485 Logger, power supply via RS-485 network RS-485 Logger, power supply via RS-485 network RS-485 Logger, power supply via RS-485 network Logger with power supply RS-485
More informationEM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter
EM132 MULTI-FUNCTION TRANSDUCER SATEC EM132 is a Smart DIN Rail Multi-Function Transducer with a local display. It is based on SATEC s best seller PM130 PLUS with an off-the-shelf LCD display (similar
More informationWLS-TC Specifications
Specifications Document Revision 1.0, February, 2010 Copyright 2010, Measurement Computing Corporation Typical for 25 C unless otherwise specified. Specifications in italic text are guaranteed by design.
More informationTU531, TU532 Terminal Unit
Ordering Data DATA SHEET TU531, TU532 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 217 200 R0001 1SAP 217 000 R0001 1SAP 417 000 R0001 TU531, terminal unit, 230 VAC,
More informationElecsys ISM-4. Remote Monitoring System
Elecsys ISM-4 Remote Monitoring System Installation and Product Specification Manual ISM4-L1 (Modbus) 81-0049-03 Rev B Page 1 of 15 Elecsys ISM-4 Contents 1 Getting Started... 3 1.1 Applications... 3 1.2
More informationBlackbox Controllers:
Blackbox Controllers: Level measurement made simple Compact low cost intelligent controllers Will operate on all db transducers up to 40m range Solids, powders and liquids level measurement Separation
More informationRIC PROGRAMMABLE INTELLIGENT CONTROLLER
Section F PROGRAMMABLE INTELLIGENT CONTROLLER intelligent controller is a new type of programmable controller. It is programmed by the use of a Function Block Diagram. The programming of is easier to learn
More informationUCM 94/1 3G/GPRS Modem for RTU32 Series
UCM 94/1 3G/GPRS Modem for RTU32 Series Data Sheet 40332 v1.00 / May 1 st, 2013 INTRODUCTION UCM 94/1 is an industrial 3G/UMTS/GPRS Modem designed for use with the Brodersen RTU32 Series. The UCM 94 support
More informationUSB-500/600 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
More informationReally Performs! Here is a Hand-Held Data Logger that Royalton Rd. Cleveland, OH USA Tel: (440) Fax: (440)
Here is a Hand-Held Data Logger that Really Performs! 10100 Royalton Rd. Cleveland, OH 44133 USA Tel: (440) 237-3200 Fax: (440) 237-1744 http://instserv.com Temperature monitoring has long been recognized
More informationKDG27. GPS Tracker. Vehicle or Personal Position Tracking Vehicle Status and Speed Tracking. Auto Accident Report Global Position System (GPS)
Vehicle or Personal Position Tracking Vehicle Status and Speed Tracking Auto Accident Report Global Position System (GPS) Navigation System Anti-theft Alarm System Overview 1. GPS data tracking via GSM
More informationGSM HOME SECURITY SYSTEM
Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : BS120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5. BASIC
More informationMillenium II +: general characteristics
Millenium II +: general characteristics Starter kit Blind Temperature sensors Special starter kits Bare board Power supply Level detection Local extensions Accessories Standard Expandable Adjacent extensions
More informationBACnet. b3810 Series Local Controllers
BACnet b380 Series Local Controllers The Andover Continuum TM b380 series controllers are designed for control of Air Handling Units, Roof Top Units, and other mechanical plant equipment. 0 Features Choose
More informationKTC. Preset Counter/ Timer. Programmable Type. Model Number Legend SALIENT FEATURES. Sensing. Digital Panel Meters
Preset Counter/ Timer Programmable Type Model Number Legend SALIENT FEATURES 6 Digits PV, SV Universal Input Dual alarm output MODBUS via RS-485 High Speed - 10 KCPS Multiple output modes Batch Counting,
More informationDS BAS 08/99 UNC 532
DS 13.310 BAS 08/99 UNC 532 BUILDING AUTOMATION SYSTEM UNIVERSAL NETWORK CONTROLLER The Universal Network Controller (UNC 532) is a fully intelligent standalone* outstation specifically designed for sites
More informationSmart Metering Monitoring and Control
ANVO- SYSTEMS Smart Metering Monitoring and Control ADVANCED NON- VOLATILE SYSTEMS Non-Volatile nvsram in High Reliable and Resilient Smart Applications With Dresden, Non-Volatile 06.10.2015 nvsram Memories
More informationUnitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000
Technical Specification Sheet Rev. 6, March, 2000 Unitary Controller The Unitary Controller can operate as an independent stand-alone controller, or can be connected to the APOGEE Automation System via
More informationRT4F-110V/25A RECTIFIER
The RT4F-110V/25A is a hot-pluggable switched mode rectifier (SMR) module designed to provide up to 25A of output current into a 110V nominal system. Examples of such systems are 60 cells lead acid (136V
More informationRTU32S RTU32S Series Small Compact Utility RTU
RTU32S RTU32S Series Small Compact Utility RTU Data Sheet 40270 v1.05 / July 7th, 2014 INTRODUCTION Brodersen Small Compact RTU32S Series with RTU/PLC functionality. The RTU32S series is based on an embedded
More informationTECHNICAL SPECIFICATION OF GPRS based MODEM (Part 1)
TECHNICAL SPECIFICATION OF GPRS based MODEM (Part 1) 1. SCOPE: The scope of work is on turn-key basis covering modem supplies, solution engineering. Supply of GPRS Modems for data acquisition from HT/
More informationGeneral information Engineering with Programming package. Display with display
Datasheet SIPLUS S7-1200 CPU 1212C AC/DC/RLY -40... +70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7212-1BE31-0XB0. COMPACT CPU, AC/DC/RELAY, ONBOARD I/O: 8 DI 24V DC 6 DO RELAY 2A 2 AI 0-10V DC, POWER
More informationKAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G. User manual
KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G User manual Martem AS 2014 CONTENTS 1. Description...3 2. Features...3 3. Interfaces...3 4. Indication and switches...4 4.1 State LED indication...4
More informationRTU32S RTU32S Series Small Compact Utility RTU
RTU32S RTU32S Series Small Compact Utility RTU Data Sheet 40270 v1.03 / February 10th, 2013 INTRODUCTION Brodersen Small Compact RTU32S Series with RTU/PLC functionality. The RTU32S series is based on
More informationGeneral information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current
Datasheet SIPLUS S7-1200 CPU 1214C DC/DC/DC -40... +70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7214-1AG31-0XB0. COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER
More informationTF501, TF521 Terminal Bases
Ordering Data DATA SHEET TF501, TF521 Terminal Bases 1 Ordering Data Part No. Scope of delivery Product life cycle status 1SAP 117 000 R0271 1SAP 317 000 R0271 1SAP 117 200 R0271 1SAP 317 200 R0271 TF501-CMS,
More informationThe IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.
IQ300 Wall Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high
More informationBACnet. b3867 Terminal Controllers
BACnet b3867 Terminal Controllers The Andover Continuum TM b3867 is a native BACnet controller that communicates on an RS-485 field bus as a Master device using the MS/TP BACnet protocol. 02 Features Product
More informationThe IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.
IQ240 Panel Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high
More informationUser s Guide. OM-EL-WiFi-TH. Shop online at omega.com. OM-EL-WiFi-T-PLUS. Data Logging Sensor
SM Extended Warranty Program User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info OM-EL-WiFi-TH OM-EL-WiFi-T-PLUS Temperature/ High Accuracy WiFi Humidity
More informationPart No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version
Ordering Data DATA SHEET TU520 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 214 400 R0001 1SAP 414 400 R0001 TU520-ETH, PROFINET I/O terminal unit, 24 VDC, spring
More informationMillenium 3 logic controllers
Millenium 3 logic controllers Type Part number Power supply Inputs Outputs With display Without display CD12 88970041 24 V c 8 digital (of which 4 are analogue) 4 x 8 A relays 88970042 24 V c 8 digital
More informationFEATURES DESCRIPTION SPECIFICATIONS
KNC-PLC-KS105 - Series FEATURES Four High-Speed Counters, Max 200 khz Four High-Speed Outputs, Max 200 khz 24VDC Power Required 8 Digital Inputs, 8 Digital Outputs 3 Year Lithium Battery for Data Retention
More informationSOFREL LT/LT-US Data loggers Wastewater network solutions
SOFREL LT/LT-US Data loggers Wastewater network solutions SOFREL LT and LT-US data loggers are designed to monitor wastewater and rainwater networks (collectors, Combined Sewer Overflows, etc.). Robust,
More informationStand-Alone, Low-Cost Data Loggers and Accessories. USB-500/600 Series Comparison Chart
Stand-Alone, Low-Cost Data Loggers and Accessories Features Stand-alone remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels
More informationJazz-J. Jazz. Features:
An All-in-One that is as affordable as a "smart relay" - full-function PLC combined with a textual HMI and keyboard, with up to 40 onboard I/Os Meet the New Jazz 2 series Advantages: Faster performance
More informationCM589 PROFINET Communication Module
Ordering Data DATA SHEET CM589 PROFINET Communication Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 172 900 R0011 1SAP 372 900 R0011 1SAP 172 900 R0111 1SAP 372 900 R0111
More informationEltek TU GenII AQ110A comprehensive portable air quality monitor transmitter
Eltek TU1082 - GenII AQ110A comprehensive portable air quality monitor transmitter AQ110A (serial number 32655 onward) is part of the Eltek GenII family of transmitters and can be used alongside any other
More informationUser s Guide. OM-EL-WiFi-TH. Shop online at omega.com. OM-EL-WiFi-TP-PLUS. Probe Data Logging Sensor
SM Extended Warranty Program User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info OM-EL-WiFi-TH OM-EL-WiFi-TP-PLUS Temperature/ High Accuracy WiFi Humidity
More informationCM579-PNIO PROFINET Communication Module
Ordering Data DATA SHEET CM579-PNIO PROFINET Communication Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 170 901 R0101 1SAP 370 901 R0101 CM579-PNIO, PROFINET communication
More informationSEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits
Advanced Monitoring and Control System Compact Enclosure Full-Size Enclosure Major Features and Benefits The SEL-734B combines volt/var based capacitor bank control with power quality monitoring and advanced
More informationMSR 2400R. Rugged Power System for Military and Heavy Duty Applications
MSR 2400R Rugged Power System for Military and Heavy Duty Applications 2400 W modular power system Power supply or battery charging systems Parallel n+1 connection, up to 90A Series connection, up to 360VDC
More informationLow Power Modbus GPRS Data Logger
Low Power Modbus GPRS Data Logger Low Power Data Logger suppor ng sleep mode Con nuous opera on for 5 years with internal ba ery Upload Data via GPRS and SMS on schedule Programmable data logging and upload
More informationJazz-J. Jazz. Features:
An All-in-One that is as affordable as a "smart relay" - full-function PLC combined with a textual HMI and keyboard, with up to 40 onboard I/Os Meet the New Jazz 2 series Advantages: Faster performance
More informationSCADAPack 50. Wireless Remote Data Logger
SCADAPack 50 Wireless Remote Data Logger 1 SCADAPack 50 Wireless Data Logger for Remote Process Monitoring The SCADAPack 50 (SP50) data logger is a compact autonomous device that monitors analog, discreet,
More informationVIBRATION MONITOR CX-RLY
VIBRATION MONITOR CX-RLY MaintTech Norrkoping Airport Sweden Email: mainttech@live.se Website: www.mainttech.se 1 CX-RLY-C MODULE Version 1 1 Important User Information Solid-state equipment has operational
More informationDisplay. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory
Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, AC/DC/RLY, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA MEMORY: 75 KB Display with
More informationDM650TM SENSOR / WALL MOUNTED TEMPERATURE DISPLAY
DM650TM UNIVERSAL RTD OR THERMOCOUPLE INPUT BATTERY POWERED USB AND NFC INTERFACE ALARM RELAY / USER SET DISPLAY MESSAGES 5000 POINT DATA LOGGER INTRODUCTION The DM650TM battery powered indicator accepts
More informationRT4F-48V/50A-WAC RECTIFIER
The RT4F-48V/50A-WAC is a switched mode rectifier (SMR) module designed to provide up to 58A of output current into a 48V nominal system, over a wide range of AC input voltage. This rectifier has been
More informationSM100. On-Line Switchgear Condition Monitoring
On-Line Switchgear Condition Monitoring On-Line Switchgear Condition Monitoring Introduction Weis is a specialist company with over 40 years of experience in the commissioning, testing & maintenance of
More informationVOICE and/or DATA CELLULAR SYSTEM
... VOICE and/or DATA CELLULAR SYSTEM The Voice/Data or Data Only Cellular System operates on DoorKing s cellular network that is hosted on the AT&T G LTE network where available. The system provides voice
More informationAndover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator
Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator The i2865 and i2866 are unique, low-cost VAV box controllers that come equipped with a built-in actuator to streamline hardware
More informationDMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions
www.vaisala.com DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions The display shows measurement trends, real-time data, and measurement history. Features/Benefits Measures dew
More informationSpecifications FEATURES
407 15216 North Bluff Road White Rock, BC Canada V4B 0A7 Phone: 604.424.9092 Toll Free: 1.877.352.9158 Fax: 1.877.453.0658 Email: info@microedgeinstruments.com Web: www.microedgeinstruments.com Specifications
More informationGeneral information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current
Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Engineering
More information24/48V Battery Bank Ah High Cycling Long Life
Outdoor Power Cabinets, 48V DC Free Cooled with Combined Air-Con. PreFactory assembled with 19 inch Power sub rack, 2 or 4 battery Shelf s, 3U DCAC Panel combined with rectifiers 2U or 4U Power Module
More informationBVR Series Battery Voltage Recorders
BVR Series Battery Voltage Recorders Handheld - from 0,5 to 0,7 kg (1.1 to 1.5 Ibs) depending on the model Max voltage measurement range ± 600 V Automatically measures, time-stamps and stores cell/string
More information5 to100 Amperes Linear Power Supply/Charger (120 Volt 60Hz) (220 Volt 50Hz)
5 to100 Amperes Linear Power Supply/Charger (120 Volt 60Hz) (220 Volt 50Hz) Products Options 120 volt 60Hz AC input, 54 volt 5 to 100 Amp output Linear Charger: 220/240 volt 50/60Hz AC input, 54 volt 5
More informationx x 60 mm, 700 gm. Wall mounted enclosure, 1 Kg. Weatherproof, high impact GF ABS. Remote control and monitoring with debug features
Smart Hub Intelligent Energy Management and IoT Hub Unit (CT200i) General Dimension and weight 202.73 x 267.45 x 60 mm, 700 gm Dimension with standard cover 268 x 204 x 56 mm Dimension with weatherproof
More informationALL PSU Ltd ROTATION+ 6kVA - 10kVA PARALLEL ON LINE DOUBLE CONVERSION
ALL PSU Ltd Unit D6 Laser Quay, Culpeper Close Medway City Estate, Rochester, Kent, ME2 4HU Phone: 01634-725527 Fax: 01634-739111 E-mail: sales@allpsu.co.uk Web: www.allpsu.co.uk ROTATION+ 6kVA - 10kVA
More informationIRM-5000P. insulation resistance meter. Vanguard Instruments Company, Inc.
IRM-5000P insulation resistance meter Vanguard Instruments Company, Inc. www.vanguard-instruments.com IRM-5000P insulation resistance meter The IRM-5000P is a microprocessor-based, high-voltage, insulation-test
More informationxlogic xlogic is a latest generation Micro-plcs, compact and expandable CPU, replacing mini PLCs, multiple timers, relays and counters etc.
xlogic THE PERFECT ALTERNATIVE TO LOW COST PLCs AND BASIC RELAYS IN THIS BROCHURE: ELC-18 series Standard CPU ELC-18 series Economy CPU ELC-18 series extensions ELC-12 series CPU ELC-12 series extensions
More informationGeneral information. Display. Supply voltage. Input current. Encoder supply. Output current
Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information
More informationUWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION
UWE-1707 SERIES CONTENTS ELECTRONIC WEIGHING INDICATOR OPERATION MANUAL 1. SPECIFICATIONS PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE SCALE 2. INSTALLATION 3. ROUTINE OPERATION
More informationREQUIREMENTS FOR WIRELESS, WEB-BASED MONITORING EQUIPMENT AND SERVICES FOR PUMP STATION APPLICAITONS
REQUIREMENTS FOR WIRELESS, WEB-BASED MONITORING EQUIPMENT AND SERVICES FOR PUMP STATION APPLICAITONS MANUFACTURER REQUIREMENTS The Manufacturer of the equipment and provider of related services shall provide
More informationDisplay. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory
Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB Display with display Supply
More informationGeneral information. Display. Supply voltage. Input current
Datasheet SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 8 DI 24V DC; 6 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information Engineering
More informationMIRRIN. Multi-Channel Load Logger MODEL: LL400 User Manual 1 GETTING STARTED INTRODUCTION CONNECTIONS
Contents MIRRIN Multi-Channel Load Logger MODEL: LL400 User Manual 1 GETTING STARTED... 3 1.1 INTRODUCTION... 3 1.2 CONNECTIONS... 3 1.3 KIT 5 1.3.1 Accessories... 5 1.3.2 Options... 5 1.4 POWER MODES...
More informationMulti-instrument Communication, MIC-2 MKII DIN Quick Start Guide
Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Warnings and legal information Installation and terminals Communication I/O options Alarming Utility software More information Specifications
More information