Innovation in Power Control

Size: px
Start display at page:

Download "Innovation in Power Control"

Transcription

1 Innovation in Power Control Revo C Catalog 2017

2 WITH REVO C YOU WILL NEVER BE ALONE CD AUTOMATION WILL GIVE YOU A REMOTE SERVICE SUPPORT ALL OVER THE WORLD VIA SMARTPHONE. Wide range of communication protocols: Connectivity of REVO C it s a premium and all the most popular protocol. Modbus RTU, Ethernet TCP, Profibus, Profinet, WiFi and USB port for data transfer. RS VDC OUTPUT +24 VDC OUTPUT DATA LOGGING RETRANSMIT FAN POWER UNIT CONTROL BOARD ANALOG INPUT ANALOG INPUT Auxiliary Power Controller Electronics Voltage sensing Zero cross sensing 2 Digital Input Enable Select feedback Local remote Set firing time Industrial Communication Profibus DP Modbus TCP Profinet 2nd modbus RTU (485) SD Memory Analog Retransmit 0 to 10 V 4 to 20 ma Backup Power User interface Communications 2 Analog Input Set point Feedback Current limit DC Power Supply Dry contact switches Potentiometers USB Device Configuration Software connections Data log file transfer Fan Power 120 or 240 VAC Monitor operation Mechanical RelayOutput Alarm Annunciation WiFi Configuration Monitor operation 2

3 CONNECTIVITY AND CONFIGURATION READ Set Point Alarm Voltage Power Current Heater Break Alarm SCR Short Circuit Alarm WRITE Set Point One by one Configuration Parameters 3

4 CD AUTOMATION CONNECT APP Download it Free of Charge YOU WILL NEVER BE ALONE.....WE GIVE YOU OUR REMOTE APP SERVICE! THE CD AUTOMATION APP WIL WORK BOTH APPLE AND ANDROID SYSTEM On this Page there are just the most important screen shot where is possible to select different functionalities: Monitor: With this function is possible to select one of the REVO C and to see the screen shot on the right with written overview. Configuration: We call it Setting where you can tap the Icon rapresenting your load connection and and Down Load the suggested configuration. Remote Service: With this feature assistance is possible to download the configuration REVO C open comments in a proper space and mail it automatically. You will receive in return CD Automation suggestions. Connection: It s possible to anable or disable Wi-Fi Overview: On this Shot Screen is possible to select the REVO C unit inside a cabinet and to see: Status: RUN, ON, DI.1, DI.2 Alarms: SC short Circuit of one or both Thyristors. HB For partial or total Load Failure with capacity to diagnostic failure of one element over 5 in parallel. TH Thermal temperature of Heat Sink in Alarm conditions. CL Current Limit active. Values: Voltage and Current in Engineering units with % Power indication. Select Setting: This facility makes your Life easier. The procedure to use it is very simple. On this page you scroll all the Icon up to when you find your drawing, you touch it and after the APP will ask you The type of Load that are. Normal Resistance, Cold Resistance (the resistance when is cold is have a very low value and increase with temperature up to 16 Times). Transformer primary coupled on secondary with Cold or Normal Resistance. When the above are selected you can Download the suggested Recipe. On this Shot Screen is posible to select the REVO C unit inside a cabinet and to see: Values: Voltage and Current in Engineering units with % Power indication Anable and Disable the REVO C Local Remote facility % P over (value adjustable) Current Limit Set Point Current Limit value in amps and in % 4

5 CONFIGURATOR SOFTWARE FAST TUNE Here are rapresented few pages of the Thyristor Configurator. The page on the left is used to configure all CD Automation products in FAST MODE. On left side there are all the wiring used. The operator select the application and declare the Type of Load that appears automatically (see the example where you can select Normal Resistance, Infrared Medium and long or Short Infrared waveform). When this selection is done on the right appear the recipe. Before to Down Load the operator can Change the Recipe parameter TEST UNIT This page of Thyristor Configurator is very useful and can be used to test all CD Automation Products. On it is possible to read and to write and to select: Voltage, Current and Power Read Out, Input Signal analog or SSR, Control Mode Selection V,I and VxI Firing Types: Half Cycle, Single Cycle, Burst Firing, Delayed Triggering Phase Angle and Soft Start Current Limit Status and Setted value. On this page is possible to activate Load Analizer that is very usefull and is as a small Oscilloscope where is possible to see the output wave form (Up to ten Variable). LOAD ANALIZER On this page the operator can select and Analize up to 10 proces variable. This feature is very important because the operator can verify if the waveform is in line with its expectations. In addition this Feature is very useful also Trouble Shooting. PROCESS VARIABLE LOGGING In REVO C Storage: xxgb SD Memory Card with programmable Logging Intervals. On other CD Automation Products the open window for logging is a Fix value internal. 5

6 FAMILY SIZE AND DIMENSIONS REVO Connect it s an Universal product range based on very powerfull micro. Current Range from 30 to 700 A Available from 1 Phase 2 Phase and 3 Phase to drive 3 Phase Loads. Its main features is the Connectivity and all the most popular Field Bus are available including WI FI (see in Ordering coding). Universal because all inputs, all firing and control mode can be configured via: Smartphone using CD Automation Connect-APP or via personal computer with CD Automation Configurator Software. CD Automation APP and Configurator Software are available free of Charge. By Phone or PC is also possible to select the suggested Recipe via ICON and Download it to REVO C (in this case you don t buy just a REVO C but the CD Automation Know How to drive your application) SR9 H 121 x W 72 x D 185-1,15kg. 1 PHASE 35-40A SR10 H 121 x W 108 x D 185-1,76kg. 2 PHASE 35-40A SR11 H 121 x W 144 x D 185-2,4kg. 3 PHASE 35-40A SR15 H 273 x W 93 x D 170-3,6kg. 1 PHASE A SR16 H 273 x W 186 x D 170-7,0kg. 2 PHASE A SR17 H 273 x W 279 x D ,6kg. 3 PHASE A S11 H 440 x W 137x D ,5kg. 1 PHASE A S12 H 520 x W 137 x D kg. 2 PHASE A S13/S14 H 440/520 x W 262 x D /22kg. 3 PHASE A 6

7 THE CHOISE IS INTERNAL OR EXTERNAL FUSES? UP TO 160A UP TO 210A UP TO 160A UP TO 210A 38,1 114,3 196,9 196,9 COMPETITOR COMPETITOR TOTAL AREA TOTAL AREA XXX cm 2 XXX cm 2 External Fuses Internal Fuses External Fuses Internal Fuses POWER CONTROL UNIT WITH INTERNAL FUSES You save space about 60% Fuse I2t selection done by CD Automation Validity of 100 KA short circuit test because has been done with same components and wiring Save labor to connect with power cable the Fuse Holder to Thyristor Power Control Unit Your cabinet become 60% less in dimension and price POWER CONTROL UNITS WITH EXTERNAL FUSE AND FUSE HOLDER More space necessary for your enclosure More space necessary in the factory where the enclosure will be allocated Do you know how much cost the space? If all the device are two time in dimensions you need two time space in your factory. UP TO 160A UP TO 210A UP TO 160A UP TO 210A 38,1 114,3 196,9 196,9 COMPETITOR COMPETITOR TOTAL AREA TOTAL AREA 616 cm cm 2 External Fuses Internal Fuses External Fuses Internal Fuses 7

8 FEATURES AND BENEFITS TRADITIONAL SYSTEM REVO C SYSTEM REVO C POWER CONTROLLER RANGE Current Range from 35 to 700 A Controlled Phases 1-2 or 3 Phases suitable to drive Normal Resistance, Cold Resistance and transformers Voltage rating 480V and 600V and 690V on some ratings. FEATURES AND BENEFITS REVO C Family integrate inside the produt: Semiconductor Fuses + Thyristors and current transformers. This save a lot of space and labor to mount and to connect Fuses. This make you secure that the 100 KA short circuit current rating is the real value because the shorrt circuit test has been done with same fuses and same support. This rating is very important because define the compliance with NEC and give the labelling value for all panels On your request short circuit current rating documentation can be supplied. Robust SCR designe to meet rugged industrial environments Easy Acces to fuses just opening the frontal door Easy acces to the Thyristor opening the frontal door Easy access to circuit board mounted internally to the front door cul 508 Listed WE ARE ABLE TO KEEP THE DIMENSION SMALLER BECAUSE WE HAVE: Fuses inside the Thyristor unit Heat Sink with very hight efficency thermal resistance (low value C/W ) In addition with fuses mounted inside the unit the Heat Sink become longer and efficency of Heat Sink become better. Part of air ventilation is used for fuse cooling 8

9 GENERAL FEATURES Fully Software Configurable Current rating Approvals Voltage All types of firing mode OLED display on front Unit Integrated Data Logging Current Control Voltage Control Power Control Diagnostic Heater Bakeout Integrate Fuse Quick and easy access to Fuses REVO C is fully Software configurable 30 to 700A for 1-2Phase unit and up to 500A for 3 Phase Unit CE-EMC and cul 508 Listed V only available => 225 A Half Cycle, Single Cycle, Burst Firing, Delayed Triggering Phase Angle and Soft Start This display give better operator interface and delivers use-friendly intuitive messages Storage:xxGB SD Memory Card with programmable Logging Intervals This feature is always available for both RMS and pick Control Normally used when Voltage Control Mode is selected Normally used when Power Control Mode is selected Powerfull Diagnostic has been implemented and when a alarm occurs the OLED Display give the messages in clear words Protect the Heathers on Start Up and eliminate labor and time to control wet heater This reduce labor and space and gives the possibility to use a part of fan cooling air to reduce the temperature of semiconductor fuses and reduce the mounting space inside the cabinet (see the comparison in the Bulletin) When open the frontal door Fuses and Thyristors are on front Industry-leading and Serviceability Generous sizing of Thyristors and Thermal Parts using hight efficency Heatsink Temperature sensor is mounted inside the units and when overcurrent occurs or Enable troubleshooting with helpful thermal system diagnostics there is high temperature inside the cabinet an alarm message appears. If the Heat Sink temperature rise a second High limit alarm switch Off the Unit 100 KA Short Circuit Current rating (SCCR) up to 600V Enable greater protection in case of Short Circuit (on request we can supply the test) Wide range of communication protocols Wi Fi Modbus RTU Ethernet TCP Profibus Profinet USB device on front unit for configuration Energy Counter Totalizer Layer based Firmware Special Algorithm for Short Wave form IR Lamp Remote service Automatic Selection of the configuration as a function of wiring and load type Fully compatible with REVO M and REVO CL serie Universal Input Universal Firing Universal Control Mode External Feed Back Control board has been engineered to plug on it different Field Bus boards This is low cost option and we suggest to use it to make possible the Smart Phone support because you can have many functions like Alarm Overview, Configuration via Icon. Remote Service and read out for each REVO C inside the cabinet Voltage, Current and Power Standard Option Option Option Standard easily and safety normally used to configure the REVO C Eliminate the user having to work in a high voltage environment because the unit is powered through USB connection This is available as an option and can be useful to define the cost per hour of heating system This is an important Feature because allows to add application software or customer software without to debug the existing one using half cycle to minize the flickering In addition a special soft start curve. This feature is available when Wi-Fi and Smart Phone are available. Use it and You will never be alone This feature is a big help for operator because we give you a recipe suggestion based on wiring and type of load. The selection is done via Icon available on Smart Phone or on Configuration Software This is an important Feature because allows to substitute old REVO with REVO C The number of terminal blocks is the same to facilitate the substitution The std analog inputs 4:20mA and 0:10V and SSR Configurable via Software Half Cycle, Single Cycle, Burst Firing, Delayed Triggering Phase Angle and Soft Start REVO C can be configured for Current, Voltage Power feed back or open loop An external signal 0:10v can be the requested control mode High precision measurement (True RMS Value for V,I and VxI).=< 1% Integrate Load Analyzer This is an important Feature that can help the operator for troubleshooting problems. This is a Real Wave Form Load Monitoring Free configuration Software A very easy and Powerful Configurator Software is availble Free of Charge on HB and Sc Alarm Alarm for Partial or Total Load Failure and Short Circuit on SCR with Electromechanical Relay output 1A at 30 Vdc or 0,5A at 125 Vac 9

10 REVO C 1PH SIZE SR9 SIZE SR15 SIZE S11 Technical Specification Dimensions: See size and dimensions page 6 Load type: Normal Resistance,Infrared Short,Medium and Long,Transformar Primary and Silicon Carbide element Inputs: 4:20mA, 0:10V, SSR and ModBus as std and different Field Bus Listed in the Product Coding Firing mode: Half Cycle,Single Cycle,Burst Firing,Delayed Triggering, Phase Angle with or without Soft Start Control Mode: Voltage,Current and Power or V2 and I2 with additional Transfer to VxI RS485 port. RTU Modbus Protocol and other Field Bus listed in Product Coding USB: port integrated for configuration in safety mode (No Load and Auxiliary Voltage needed) Unit Powered Through USB 100 KA: Short Circuit Current rating (SCCR) up to 600V cul and CE + EMC approved Option See below the types of options and their combination for Code generation Energy Totalizer Data Logging WiFi HB Alarm to diagnostic partial or Total Load Failure and Thyristor Short Circuit Tools A very easy and Powerful Configurator Software is availble Free of Charge on Connect CD Automation APP is also available free of charge to communicate via Wi-Fi I LIMIT HB WIFI LOGGING TOTALIZER CODE NOTES I LIMIT (CURRENT LIMIT) This option is used to keep the overcurrent inside setted limit. It s necessary to drive primary transformers and cold resistance HB Alarm for partial or total load failure and Short Circuit on SCR (relay output). 9 A B C D E F G H I J K L M N O P Q WiFi Option that allow to communicate with a smartphone. From smartphone via a CD Automation App to read inside a cabinet the Current, Voltage, Power and Energy totalization and in addition is possible to charge parameter of Thyristor Unit without to open the cabinet door and to move on process and see the result of product quality changing parameters. APP Free of charge download it from Google Play or Apple Store. DATA LOGGER This feature is important to see the historical data of parameter like Current, Voltage and Power and can be useful to diagnostic a fault. ENERGY TOTALIZER This function totalize the energy consumption of the load allowing the calculation of Heating Treatment. R S T U V 10

11 CONNECTIVITY see note 1 L/R F RS-485 INPUT RS485 POT 10K 0-10V 4-20mA SSR OPTIONS HB SCR cc HB+SCR cc An/Out Config Digital Input Alarm Relay Output Std MODBUS RS485 FIRING Delay Trig. Single Cycle Burst Firing BF+Soft Start Zero Crossing Phase Angle CONTROL MODE V I VxI REVO C 1 PH ORDER CODE: REVO C 1PH R C 1 _ - CURRENT FUSES CONTROL MODE 11 description description code note description code Note 35A Fuse + Fuse Holder Included Open Loop O 40A Fuse + Fuse Holder Included Voltage U 60A Fixed Fuses Included Voltage Square Q 90A Fixed Fuses Included Current I 120A Fixed Fuses Included Current Square A 150A Fixed Fuses Included Power VxI W 180A Fixed Fuses Included A Fixed Fuses Included OPTION A Fixed Fuses Included description code Note 400A Fixed Fuses Included No Option 0 500A Fixed Fuses Included option code see previous page table A Fixed Fuses Included A Fixed Fuses Included FAN VOLTAGE A Fixed Fuses Included description code Note No Fan < 120A 0 MAX VOLTAGE 7 Fan 110V >= 120A 1 description code note Fan 220V >= 120A Std Version V V 6 APPROVALS V 7 description code Note CE EMC For European Market O VOLTAGE SUPPLY AUX. 8 CUL us + CE EMC For American & European Market L 2 description code note 100/120Vac 1 LOAD TYPE /208/230/240Vac 2 description code Note 277Vac 3 1 PH Normal Resistance 0 380/415/480Vac 5 1 PH IRSW Infrared Short Wave 1 600Vac 6 1 PH MoSi2 Heaters 2 690Vac 7 1 PH SiC Heaters 3 1 PH Transformer Coupled with Normal Resistance 4 INPUT 9 1 PH Transformer Coupled with MoSi2 Heaters 5 description code note 1 PH Transformer Coupled with SiC Resistance 6 SSR S 1 PH Transformer Coupled with UV Lamp 7 0:20mA B 4:20mA A COMMUNICATION AND RETRANSMISSION 16 0:10V V description description code Note 10KPot K No Retransmission 0 N 1 Modbus RTU Retransmission 4:20mA 1 FIRING START OPTION 10 Retransmission 0:10V 2 description description code note No Retransmission 3 Single Cycle No Soft Start C N 2 Modbus RTU Retransmission 4:20mA 4 Linear Soft Starter S Retransmission 0:10V 5 No Soft Start H No Retransmission 6 Half Cycle Linear Soft Starter L N 1 Profibus DP + N 1 Modbus RTU Retransmission 4:20mA 7 Soft Start for Infrared Lamp I Retransmission 0:10V 8 Burst Firing No Soft Start B No Retransmission 9 Linear Soft Starter J N 2 Profinet DP + N 1 Modbus RTU Retransmission 4:20mA A Phase Angle No Soft Start P Retransmission 0:10V B Linear Soft Starter E No Retransmission C Delayed Triggering No Soft Start D N 2 Modbus TCP + N 1 Modbus RTU Retransmission 4:20mA D Linear Soft Starter T Retransmission 0:10V E Zero Crossing No Soft Start Z Note 1: Fixed Fuses over 40A Linear Soft Starter R Note 2: No cul approved 800A 11

12 REVO C 2PH SIZE SR10 SIZE SR16 SIZE S14 Technical Specification Dimensions: See size and dimensions page 6 Load type: Normal Resistance,Infrared Short,Medium and Long,Transformar Primary using Delayed Triggering Inputs: 4:20mA, 0:10V, SSR and ModBus as std and different Field Bus Listed in the Product Coding Firing mode: Burst Firing, Delayed Triggering Control Mode: Voltage,Current and Power or V2 and I2 with additional Transfer to VxI RS485 port. RTU Modbus Protocol and other Field Bus listed in Product Coding USB: port integrated for configuration in safety mode (No Load and Auxiliary Voltage needed) Unit Powered Through USB Complay with EMC and cul 100 KA: Short Circuit Current rating (SCCR) up to 600V Option See below the types of options and their combination for Code generation Energy Totalizer Data Logging WiFi HB Alarm to diagnostic partial or Total Load Failure and Thyristor Short Circuit Tools A very easy and Powerful Configurator Software is availble Free of Charge on Connect CD Automation APP is also available free of charge to communicate via Wi-Fi I LIMIT HB WIFI LOGGING TOTALIZER CODE NOTES A B C D E F I LIMIT (CURRENT LIMIT) This option is used to keep the overcurrent inside setted limit. It s necessary to drive primary transformers and cold resistance HB Alarm for partial or total load failure and Short Circuit on SCR (relay output). WiFi Option that allow to communicate with a smartphone. From smartphone via a CD Automation App to read inside a cabinet the Current, Voltage, Power and Energy totalization and in addition is possible to charge parameter of Thyristor Unit without to open the cabinet door and to move on process and see the result of product quality changing parameters. APP Free of charge download it from Google Play or Apple Store. DATA LOGGER This feature is important to see the historical data of parameter like Current, Voltage and Power and can be useful to diagnostic a fault. ENERGY TOTALIZER This function totalize the energy consumption of the load allowing the calculation cost of Heating Treatment. 12

13 CONNECTIVITY see note 1 L/R F RS-485 INPUT RS485 POT 10K 0-10V 4-20mA SSR FIRING Burst Firing Zero Crossing OPTIONS HB SCR cc HB+SCR cc An/Out Config Digital Input Alarm Relay Output MODBUS Std RS485 CONTROL MODE V VxI I REVO C 2 PH ORDER CODE: REVO C 2PH R C 2 _ - CURRENT FUSES CONTROL MODE 11 description description code note description code Note 30A Fuse + Fuse Holder Included Open Loop O 35A Fuse + Fuse Holder Included Voltage U 40A Fuse + Fuse Holder Included Voltage Square Q 60A Fixed Fuses Included Current I 90A Fixed Fuses Included Current Square A 120A Fixed Fuses Included Power VxI W 150A Fixed Fuses Included A Fixed Fuses Included OPTION A Fixed Fuses Included description code Note 300A Fixed Fuses Included No Option 0 400A Fixed Fuses Included option code see previous page table A Fixed Fuses Included A Fixed Fuses Included FAN VOLTAGE A Fixed Fuses Included description code Note 700A Fixed Fuses Included No Fan < 120A 0 800A Fixed Fuses Included Fan 110V >= 120A 1 Fan 220V >= 120A Std Version 2 MAX VOLTAGE 7 description code note APPROVALS V 4 description code Note 600 V 6 CE EMC For European Market O 690V 7 CUL us + CE EMC For American & European Market L 2 VOLTAGE SUPPLY AUX. 8 LOAD TYPE 15 description code note description code Note 100/120Vac 1 Normal Resistive with 3 Phase Star Connection 0 200/208/230/240Vac 2 Normal Resistive Load with three Phase Delta & Star Connection 1 277Vac 3 IRSW Infrared Short wave with 3 Phase Star Connection 2 380/415/480Vac 5 IRSW Infrared Short wave with 3 Phase Delta Connection 3 600Vac 6 690Vac 7 COMMUNICATION AND RETRANSMISSION 16 description description code Note INPUT 9 No Retransmission 0 description code note N 1 Modbus RTU Retransmission 4:20mA 1 SSR S Retransmission 0:10V 2 0:20mA B No Retransmission 3 4:20mA A N 2 Modbus RTU Retransmission 4:20mA 4 0:10V V Retransmission 0:10V 5 10KPot K No Retransmission 6 N 1 Profibus DP + N 1 Modbus RTU Retransmission 4:20mA 7 FIRING START OPTION 10 Retransmission 0:10V 8 description description code note No Retransmission 9 Burst Firing No Soft Start B N 2 Profinet DP + N 1 Modbus RTU Retransmission 4:20mA A Zero Crossing No Soft Start Z Retransmission 0:10V B No Retransmission C Note 1: Fixed Fuses over 40A N 2 Modbus TCP + N 1 Modbus RTU Retransmission 4:20mA D Note 2: No cul approved 800A Retransmission 0:10V E 13

14 REVO C 3PH SIZE SR11 SIZE SR17 SIZE S14 Technical Specification Dimensions: See size and dimensions page Load type: Normal Resistance,Infrared Short,Medium and Long,Transformar Primary using Phase Angle Inputs: 4:20mA, 0:10V, SSR and ModBus as std and different Field Bus Listed in the Product Coding Firing mode: Burst Firing, Delayed Triggering and Phase Angle with or without Soft Start Control Mode: Voltage,Current and Power or V2 and I2 with additional Transfer to VxI RS485 port. RTU Modbus Protocol and other Field Bus listed in Product Coding USB: port integrated for configuration in safety mode (No Load and Auxiliary Voltage needed) Unit Powered Through USB Complay with EMC and cul 100 KA: Short Circuit Current rating (SCCR) up to 600V Option See below the types of options and their combination for Code generation Energy Totalizer Data Logging WiFi HB Alarm to diagnostic partial or Total Load Failure and Thyristor Short Circuit Tools A very easy and Powerful Configurator Software is availble Free of Charge on Connect CD Automation APP is also available free of charge to communicate via Wi-Fi I LIMIT HB WIFI LOGGING TOTALIZER CODE NOTES I LIMIT (CURRENT LIMIT) This option is used to keep the overcurrent inside setted limit. It s necessary to drive primary transformers and cold resistance A B C D E F G HB Alarm for partial or total load failure and Short Circuit on SCR (relay output). WiFi Option that allow to communicate with a smartphone. From smartphone via a CD Automation App to read inside a cabinet the Current, Voltage, Power and Energy totalization and in addition is possible to charge parameter of Thyristor Unit without to open the cabinet door and to move on process and see the result of product quality changing parameters. H I J K L M APP Free of charge download it from Google Play or Apple Store. DATA LOGGER This feature is important to see the historical data of parameter like Current, Voltage and Power and can be useful to diagnostic a fault. N O P Q ENERGY TOTALIZER This function totalize the energy consumption of the load allowing the calculation cost of Heating Treatment. R S T U V 14

15 CONNECTIVITY see note 1 L/R F RS-485 INPUT RS485 POT 10K 0-10V 4-20mA SSR FIRING Burst Firing Zero Crossing OPTIONS HB SCR cc HB+SCR cc An/Out Config Digital Input Alarm Relay Output MODBUS RS485 CONTROL MODE V VxI I REVO C 3 PH ORDER CODE: REVO C 3PH R C 3 _ - CURRENT FUSES CONTROL MODE 11 description description code note description code Note 30A Fuse + Fuse Holder Included Open Loop O 35A Fuse + Fuse Holder Included Voltage U 40A Fuse + Fuse Holder Included Voltage Square Q 60A Fixed Fuses Included Current I 90A Fixed Fuses Included Current Square A 120A Fixed Fuses Included Power VxI W 150A Fixed Fuses Included A Fixed Fuses Included OPTION A Fixed Fuses Included description code Note 300A Fixed Fuses Included No Option 0 400A Fixed Fuses Included option code see previous page table A Fixed Fuses Included A Fixed Fuses Included FAN VOLTAGE A Fixed Fuses Included description code Note 700A Fixed Fuses Included No Fan < 120A 0 800A Fixed Fuses Included Fan 110V >= 120A 1 Fan 220V >= 120A Std Version 2 MAX VOLTAGE 7 description code note APPROVALS V 4 description code Note 600 V 6 CE EMC For European Market O 690V 7 CUL us + CE EMC For American & European Market L 2 VOLTAGE SUPPLY AUX. 8 LOAD TYPE 15 description code note description code Note 100/120Vac 1 Normal Resistive with 3 Phase Star Connection 0 200/208/230/240Vac 2 Normal Resistive Load with three Phase Delta & Star Connection 1 277Vac 3 IRSW Infrared Short wave with 3 Phase Star Connection 2 380/415/480Vac 5 IRSW Infrared Short wave with 3 Phase Delta Connection 3 600Vac 6 690Vac 7 COMMUNICATION AND RETRANSMISSION 16 description description code Note INPUT 9 No Retransmission 0 description code note N 1 Modbus RTU Retransmission 4:20mA 1 SSR S Retransmission 0:10V 2 0:20mA B No Retransmission 3 4:20mA A N 2 Modbus RTU Retransmission 4:20mA 4 0:10V V Retransmission 0:10V 5 10KPot K No Retransmission 6 N 1 Profibus DP + N 1 Modbus RTU Retransmission 4:20mA 7 FIRING START OPTION 10 Retransmission 0:10V 8 description description code note No Retransmission 9 Burst Firing No Soft Start B N 2 Profinet DP + N 1 Modbus RTU Retransmission 4:20mA A Linear Soft Starter J Retransmission 0:10V B Phase Angle No Soft Start P No Retransmission C Linear Soft Starter E N 2 Modbus TCP + N 1 Modbus RTU Retransmission 4:20mA D Delayed Triggering No Soft Start D Retransmission 0:10V E Zero Crossing No Soft Start Z Note 1: Fixed Fuses over 40A Linear Soft Starter R Note 2: No cul approved 800A 15

16 16 INTEGRATED FIELDBUS

17 SYSTEM ARCHITECTURE WITH DIFFERENT FIELDBUS CHAIN CONNECTION STAR CONNECTION 17

18 Italy CD Automation Srl Via Picasso, 34/ Legnano MI Italy T F sales@cdautomation.com CD Automation Srl (Facility) Cantalupo MI Italy India M/s Toshcon CD Automation Pvt. Ltd. H1-75 Gegal Industrial Area Ajmer India T /3/4/5 T /2/3 info@toshcon.com England CD Automation UK Ltd Unit 9 Harvington Business Park Brampton Road, Eastbourne East Sussex, BN22 9BN England T info@cdautomation.co.uk

Innovation in Power Control

Innovation in Power Control Internal Fuses on complete range 30 to 800A 100 ka Short Circuit Current (SCCR) up to 600V Voltage Supply 480-600-690V OLED Display for easy Diagnostic & Configuration All Firing & Control Mode available

More information

Innovation in Power Control

Innovation in Power Control Internal Fuses on complete range 30 to 800 100K K Short Circuit Current (SCCR) Voltage Supply 480-600-690V OLED Display for easy Diagnostic & Configuration ll Firing & Control Mode available Wi Fi and

More information

Multi-Channel SCR Power Controller Suitable to control Electric Heaters and IR Lamps in Industrial Heating Systems

Multi-Channel SCR Power Controller Suitable to control Electric Heaters and IR Lamps in Industrial Heating Systems Multi Channel Power Control Suitable to communicate with PLC & Multiloop Dedicated to solve applications Space & wiring reduction Most popular Field Bus available CE EMC and cul listed Elimination of power

More information

ASPYRE Power Controllers. Modular and Scalable Power Controller Family Ideal for a Wide Range of Applications SPECIFICATION SHEET

ASPYRE Power Controllers. Modular and Scalable Power Controller Family Ideal for a Wide Range of Applications SPECIFICATION SHEET SPECIFICATION SHEET ASPYRE Power Controllers Modular and Scalable Power Controller Family Ideal for a Wide Range of Applications Watlow s new ASPYRE power controller family is flexible and scalable, and

More information

ASPYRE Power Controllers. Modular and Scalable Power Controller Family Ideal for a Wide Range of Applications SPECIFICATION SHEET

ASPYRE Power Controllers. Modular and Scalable Power Controller Family Ideal for a Wide Range of Applications SPECIFICATION SHEET SPECIFICATION SHEET ASPYRE Power Controllers Modular and Scalable Power Controller Family Ideal for a Wide Range of Applications Watlow s new ASPYRE power controller family is flexible and scalable, and

More information

ASPYRE Power Controllers. Modular and Scalable Power Controller Family Ideal for a Wide Range of Applications SPECIFICATION SHEET

ASPYRE Power Controllers. Modular and Scalable Power Controller Family Ideal for a Wide Range of Applications SPECIFICATION SHEET SPECIFICATION SHEET ASPYRE Power Controllers Modular and Scalable Power Controller Family Ideal for a Wide Range of Applications Watlow s new ASPYRE power controller family is flexible and scalable, and

More information

ASPYRE Power Controllers. Modular and Scalable Power Controller Family Ideal for a Wide Range of Applications SPECIFICATION SHEET

ASPYRE Power Controllers. Modular and Scalable Power Controller Family Ideal for a Wide Range of Applications SPECIFICATION SHEET SPECIFICATION SHEET ASPYRE Power Controllers Modular and Scalable Power Controller Family Ideal for a Wide Range of Applications Watlow s new ASPYRE power controller family is flexible and scalable, and

More information

THYRO-FAMILY SCR POWER CONTROLLERS THYRO-S THYRO-A THYRO-AX THYRO-PX

THYRO-FAMILY SCR POWER CONTROLLERS THYRO-S THYRO-A THYRO-AX THYRO-PX THYRO-FAMILY SCR POWER CONTROLLERS THYRO-S THYRO-A THYRO-AX THYRO-PX THYRO-FAMILY DIGITAL SCR POWER CONTROLLERS LEADING TECHNOLOGY, PROVEN SOLUTIONS No other SCR power ler series offers the flexibility

More information

ASPYRE. with an intelligent power controller family that simplifies your application while offering

ASPYRE. with an intelligent power controller family that simplifies your application while offering ASPYRE with an intelligent power controller family that simplifies your application while offering cutting-edge features Modular and Smart Design Easy to Use and Service > Easy to read real character r

More information

THYRO-FAMILY SCR POWER CONTROLLERS

THYRO-FAMILY SCR POWER CONTROLLERS THYRO-FAMILY SCR POWER CONTROLLERS THYRO-S THYRO-A THYRO-AX THYRO-PX 2018 Advanced Energy Industries, Inc. Leading Technology, Proven Solutions Thyro-Family Digital SCR Power Controllers No other SCR power

More information

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS MICROFUSION THREE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC Output 16, 32, 50, 80 Amps (@ 50 C 6000 ft) Control Features Microprocessor-based controller /

More information

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3. Line A Inverse parallel scrs Load a Line B FUSION SCR POWER O delta CONTROLLERS Line c inverse parallel scrs Load C FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC or DC Output AC Models: 50-1200

More information

FUSION COMPACT. Load a. Line A. Inverse parallel scrs. Line B. Line c. inverse parallel scrs. Load C SCR POWER. O delta CONTROLLERS

FUSION COMPACT. Load a. Line A. Inverse parallel scrs. Line B. Line c. inverse parallel scrs. Load C SCR POWER. O delta CONTROLLERS Line A Inverse parallel scrs Load a Line B COMPACT SCR POWER CONTROLLERS O delta Line c inverse parallel scrs Load C 1 Compact Brochure Rev 3.51 www.ccipower.com 1-800-765-2799 FEATURES Auto-Ranging Input

More information

EZ-ZONE ST. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy SPECIFICATION SHEET

EZ-ZONE ST. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy SPECIFICATION SHEET EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy EZ-ZONE ST 75 ampere configuration SPECIFICATION SHEET EZ-ZONE ST 40 ampere full configuration with mechanical

More information

Revo PC. USER S MANUAL Rev. 05/2011

Revo PC. USER S MANUAL Rev. 05/2011 USER S MANUAL Rev. 05/2011 Revo PC 00003 CD Automation S.r.l. Via Picasso 34/36-20025 Legnano (MI) ITALY Tel +39 0331 577479 Fax +39 0331 579479 E-Mail: info@cdautomation.com - WEB: www.cdautomation.com

More information

EZ-ZONE ST. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy

EZ-ZONE ST. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy EZ-ZONE ST 75 ampere configuration 40 ampere full configuration with mechanical contactor configuration with only the controller and SSR EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements

More information

REVO C Serial Communication Manual

REVO C Serial Communication Manual USER S MANUAL Rev. 08/2018 Preliminary REVO C Serial Communication Manual 0007 1 Sommario 1 MODBUS-RTU communication protocol... 3 Communication Terminals 30-40A (SR9-SR10-SR11) 3 1.1.1 RS485 STANDARD

More information

THYRO-FAMILY. Thyro-S Thyro-A Thyro-AX Thyro-P

THYRO-FAMILY. Thyro-S Thyro-A Thyro-AX Thyro-P THYRO-FAMILY Thyro-S Thyro-A Thyro-AX Thyro-P DIGITAL POWER CONTROLLER State-of-the-Art Technology Industries/Applications Automotive industry Chemical industry and mineral oil industry Crystal growing

More information

Adaptable power control

Adaptable power control Adaptable power control EPack-2PH compact SCR power controllers Three phase 2 leg control Designed for fast integration and optimum efficiency Product at a glance OEMs and system integrators need to be

More information

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1 4/8/2015 52 nd Annual OTCO WW Workshop W/WW Product Overview ACQ550 Slide 1 Drive Basics Why Use Adjustable Speed Drives? Reduced Energy Consumption Improved Process Control / Efficiency Increased Product

More information

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC The PCI Series Phase Angle Fired SCR Power Controls 25-1200 AMPS 120-600 VAC Precise power control for complex SCR applications. ROBICON 1996 Distributed Worldwide by www.mcgoff-bethune.com Applications

More information

THYRO-S THYRO-A THYRO-AX THYRO-PX

THYRO-S THYRO-A THYRO-AX THYRO-PX THYRO-FAMILY = ACCESSORIES THYRO-S THYRO-A THYRO-AX THYRO-PX 2018 Advanced Energy Industries, Inc. Enhance Your Thyro-Family THYRO-FAMILY SCR POWER CONTROLLERS Thyro-Family Accessories No other SCR power

More information

Adaptable power control

Adaptable power control Adaptable power control EPack-3PH compact SCR power controllers Three phase 3 leg control Designed for fast integration and optimum efficiency Product at a glance OEMs and system integrators need to be

More information

Essential Power Control

Essential Power Control Essential Power Control EPack TM Lite-2PH Compact SCR Power Controllers Three Phase 2 Leg Control Simplicity Without Compromise On Performance Product at a Glance The end user, the machine builder or the

More information

Controls. Reduced Power Cost Extended Heater Life Less Maintenance Improved Process Products Stable Process Temperature. 4232/4233 Features

Controls. Reduced Power Cost Extended Heater Life Less Maintenance Improved Process Products Stable Process Temperature. 4232/4233 Features 40 Series SCR-Zero Crossover Control 00 to 00 Amps Louvered, Fan Cooled Enclosures Main Disconnect Switch with Shunt Trip 08-600 Volt Control Power Transformer 4 NEMA or NEMA Leg, Phase MaxPac II DOT Fired

More information

Adaptable power control

Adaptable power control Adaptable power control EPack-PH compact SCR power controllers Designed for fast integration and optimum efficiency Product at a glance OEMs and system integrators need to be able to react quickly to customer

More information

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III Compact DC Drive Package The delivers a DC drive package that integrates the intelligence of the Mentor II with a space saving design that incorporates many accessories typically required in the North

More information

REVO CL Serial Communication Manual

REVO CL Serial Communication Manual USE S MANUAL ev. 09/2014 EVO CL Serial Communication Manual 00009 CD Automation S.r.l. Via Picasso 34/36-20025 Legnano (MI) ITALY Tel +39 0331 577479 Fax +39 0331 579479 E-Mail: info@cdautomation.com -

More information

EZ-ZONE. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy

EZ-ZONE. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy EZ-ZONE ST EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy The new EZ-ZONE ST integrated control loop solid state controller from Watlow offers complete thermal

More information

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter Standard Options Model 4100 Position Indicating Meter A percent-of-full-travel meter is supplied with a trim potentiometer resistor, terminal block and connectors. A potentiometer is required in the actuator

More information

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018 Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018 Tags: P-8 1800RPM Premium Efficient Motor 460/3/60 Pump and Motor Weight: 183lbs

More information

USER S MANUAL. DAS-G01 The Power of Tomorrow

USER S MANUAL. DAS-G01 The Power of Tomorrow USER S MANUAL DAS-G01 The Power of Tomorrow Richmond Heights 2018 0 USER S MANUAL DAS-G01 The Power of Tomorrow Richmond Heights 2018 Page 1 USER'S MANUAL TABLE OF CONTENTS Page # 1.0 GENERAL INFORMATION...

More information

JUMO TYA 201 Single-Phase SCR Power Controller For controlling resistive/inductive loads

JUMO TYA 201 Single-Phase SCR Power Controller For controlling resistive/inductive loads Data sheet 709061 Page 1/21 JUMO TYA 201 Single-Phase SCR Power Controller For controlling resistive/inductive loads The JUMO TYA 201 represents a consistent further development of the JUMO power controller

More information

Power supplies CP-E, CP-S and CP-C range NEW! CP-E Range

Power supplies CP-E, CP-S and CP-C range NEW! CP-E Range Power supplies CP-E, CP-S and CP-C range CP-E Range The new CP-E range power supplies M odern switch mode AC to DC power supplies are a vital component in most information gathering systems, energy management,

More information

WHAT YOU NEED TO KNOW ABOUT SCR POWER CONTROLLERS FUNCTIONS, FEATURES, AND EFFICIENCIES

WHAT YOU NEED TO KNOW ABOUT SCR POWER CONTROLLERS FUNCTIONS, FEATURES, AND EFFICIENCIES WHAT YOU NEED TO KNOW ABOUT SCR POWER CONTROLLERS FUNCTIONS, FEATURES, AND EFFICIENCIES ABSTRACT Temperature regulation is required in nearly every manufacturing process, typically for the purposes of

More information

USER S MANUAL Rev. 11/2003 PT -KP. for PT 3X00 & Multidrive

USER S MANUAL Rev. 11/2003 PT -KP. for PT 3X00 & Multidrive USER S MANUAL Rev. 11/2003 PT -KP for PT 3X00 & Multidrive Fuji Electric Systems Co., Ltd. No.1, Fuji-machi, Hino-shi, Tokyo 191-8502 JAPAN Tel +81-42-585-6201 Fax +81-42-585-6187 E-Mail: info@fic-net.jp

More information

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D Specification Number: 23 09 33 Product Name: FRENIC-Eco AC Drives for Variable Torque Fan & Pump Applications (1-125Hp at 208/230V and 1-900Hp at 460V) PART 1: GENERAL 1.01 SUMMARY A. This specification

More information

Adaptable power control

Adaptable power control Adaptable power control EPack-3PH compact SCR power controllers Three phase 3 leg control Designed for fast integration and optimum efficiency Product at a glance OEMs and system integrators need to be

More information

Built-in features Built-in simplicity Built for fans & pumps

Built-in features Built-in simplicity Built for fans & pumps GE Built-in features Built-in simplicity Built for fans & pumps AF-600 FP Fan & Pump Drives imagination at work Built for variable torque Specifically designed for fan and pump applications, the AF-600

More information

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis. A21 DIMMER CABINET SPECIFICATION. GENERAL. A.) Overview. 1.) The dimmer cabinets shall be fully digital, designed specifically for architectural and entertainment lighting applications, and shall consist

More information

E-Learning, DC drives DCS800 Hardware D5 D7, part 2

E-Learning, DC drives DCS800 Hardware D5 D7, part 2 E-Learning, DC drives DCS800 Hardware D5 D7, part 2 August 24, 2010 Slide 1 Objectives After completing this module, you will be familiar with: Function of POW-4 board Internal field exciter FEX-4 25 Function

More information

SSW06. Soft Starters.

SSW06. Soft Starters. The is WEG s third generation Soft Starter line. The keypad, with dual display, has red LED digits which provide visibility and make programming easier. Integral bypass contacts eliminate heat dissipation

More information

Power Meter PowerMonitor 500

Power Meter PowerMonitor 500 ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION PowerMonitor 500 NOTICE: The specification guidelines in this document are intended to aid in the specification of products. Specific

More information

Technical Explanation for Power Controllers

Technical Explanation for Power Controllers CSM_Power_s_TG_E_5_2 Introduction What Is a Power? A Power continuously adjusts the power consumed by a heater with phase control or optimum cycle control mainly by receiving an analog signal, such as

More information

Electrostatic Precipitator Controller PIACS DC4

Electrostatic Precipitator Controller PIACS DC4 Electrostatic Precipitator Controller PIACS DC4 2 Better technology Better technology, better user experience PIACS DC4 delivers User experience like never before More efficient control strategies to meet

More information

SmartVFD HVAC and BYPASS

SmartVFD HVAC and BYPASS SmartVFD HVAC and BYPASS The Smart Choice for Energy Savings. Saving Energy the Smart Way Buildings consume more than 70 percent of the electricity produced in North America and roughly half of that is

More information

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green Richmond Heights Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller Presentation Agenda 1. Introduction To Richmond Heights 2. Smart Universal Controller Features Of DAS-G01 3. DAS-G01

More information

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW) Product data sheet Characteristics ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/400...440V(37kW) Complementary Assembly style Function available Power supply voltage limits Main Range of

More information

ABB Three Phase String inverter

ABB Three Phase String inverter ITALY, JULY 2017 ABB Three Phase String inverter TRIO-TM-50.0/60.0 Product Manager EPPE PG Solar TRIO-50/60.TL-OUTD Today offer TRIO-50.0/60.0-TL-OUTD main features Developed for Commercial, industrial

More information

Product Description Page. Remote user interface and communications device 409

Product Description Page. Remote user interface and communications device 409 Product Description Page EZ-ZONE RUI and Gateway Remote user interface and communications device 409 Serial Converters Devices that bridge between serial networks 410 Combined Branch and Semiconductor

More information

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW) Characteristics soft starter-ats22-control 220V-power 230V(18.5kW)/400...440V(37kW)/500V(45kW) Price* : 683.00 GBP Main Range of product Altistart 22 Product or component type Product destination Product

More information

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h Characteristics soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h Complementary Assembly style Function available Power supply voltage limits Main Range of product Altistart

More information

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS ELK. ETK COMPACT BASIC CONTROL - SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS TIMER - SOFT START OUTPUT

More information

RFD-200 TM. Test a Wide Variety of Relays in their Outdo FEATURES AT A GLANCE. Auxiliary AC/DC Power Supply. RFD-200 S2 Ampere Meters

RFD-200 TM. Test a Wide Variety of Relays in their Outdo FEATURES AT A GLANCE. Auxiliary AC/DC Power Supply. RFD-200 S2 Ampere Meters Ergonomic Design a Make Performance RFD-200 TM Vanguard s Model RFD-200 S2 is a portable relay test set that delivers performance verification testing of electromechanical, electronic, and microprocessorbased

More information

Integrated Multi-Function

Integrated Multi-Function The panel mount controller offers control options that reduce system complexity and thermal loop ownership cost. It can be ordered as a PID controller, an over/under limit controller or its functions can

More information

POWER ELECTRONICS / SD700 SERIES SD700 VARIABLE SPEED DRIVES

POWER ELECTRONICS / SD700 SERIES SD700 VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES SD700 VARIABLE SPEED DRIVES SD700 SERIES is the core of the family, available from 1.5kW to 2200kW [1], a voltage range from 230VAC to 690VAC and available 6, 12, 18 and

More information

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA The SR series on line double conversion UPS with full time Digital Signal Processor control technology is the perfect solution for mission critical users who demand high reliability, availability and performance

More information

West Instruments. The MLC compact multi-loop controller... MLC ends the control or integration compromise

West Instruments. The MLC compact multi-loop controller... MLC ends the control or integration compromise The MLC 9000+ compact multi-loop controller... MLC 9000+...ends the control or integration compromise Why the MLC 9000+? Use the MLC 9000+ as a discrete controller mounted behi either as a stand-alone

More information

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW) Characteristics soft starter-ats22-control 220V-power 230V(15kW)/400...440V(30kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component

More information

BMS Steam Station Solutions

BMS Steam Station Solutions BMS Steam Station Solutions rtk@circor.com www.circorenergy.com Compact Programmable Controller Touch Screen Operator Panel MP-02 CPU Modem / Router Remote management using a SMARTphone Remote management

More information

User Manual. JS-ICON 624 PACK Portable Dimmer Pack. JOHNSON SYSTEMS INC. Spring

User Manual. JS-ICON 624 PACK Portable Dimmer Pack. JOHNSON SYSTEMS INC. Spring User Manual JS-ICON 624 PACK Portable Dimmer Pack JOHNSON SYSTEMS INC. Spring 2007 Table of Contents JS-ICON 624 DMX JS-ICON 624 CC 6-2.4kW Dimming Strip JS-ICON 624 ND 6-2.4kW Relay Strip Introduction...3

More information

DPS SERIES DC POWER SUPPLIES

DPS SERIES DC POWER SUPPLIES DPS SERIES: 15kW - 60kW Key features: 15kW to 60kW Models Higher Power Configurations Available 3U Compact Form Factor Voltage Ranges up to 1200 Vdc Current Ranges up to 3000 Adc High-Speed Precision Metering

More information

EZ-ZONE. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy

EZ-ZONE. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy EZ-ZONE ST EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy Watlow s new EZ-ZONE ST integrated control loop solid state controller offers complete thermal system

More information

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21 Characteristics variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21 Main Range of product Product or component type Device application Device short name Variant Product destination Mounting

More information

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS SECTION 26 29 13.16 PART 1 - GENERAL 1.1 THE REQUIREMENT A. General: The CONTRACTOR shall provide solid-state reduced voltage motor starters, complete and operable, in accordance with the Contract Documents.

More information

Industrial Control SE-607

Industrial Control SE-607 Industrial Control SE-607 Controller and visualization combined as an automation solution with infrared touch operation Trend-setting industrial controls for heat treatment plants The controller is equipped

More information

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics. Characteristics soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Main Range of product Altistart 22 Product or component type Product destination Product specific application

More information

Equipment Short-Circuit Current Rating and Available Fault Current

Equipment Short-Circuit Current Rating and Available Fault Current Equipment Short-Circuit Current Rating and Available Fault Current Dan Neeser Field Application Engineer Eaton s Bussmann Business Dan.Neeser@CooperIndustries.com Agenda Interrupting Rating & Series Rating

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW) Characteristics soft starter-ats22-control 220V-power 230V(4kW)/400...440V(7.5kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component

More information

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter Install Guide Revision C (12/18) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Revision C (12/18) Turn off all power supplying equipment

More information

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp) Characteristics softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp) Main Range of product Altistart 22 Product or component type Product destination Product specific application

More information

ADJUSTABLE SPEED DRIVES. GX7 Series

ADJUSTABLE SPEED DRIVES. GX7 Series ADJUSTABLE SPEED DRIVES GX7 Series Toshiba GX7 Toshiba s GX7 Series PWM adjustable speed drive is a severe duty drive built to handle all conventional applications in the industry, ranging from the simplest

More information

Thyro-Family. Thyro-S Thyro-A Thyro-AX Thyro-P

Thyro-Family. Thyro-S Thyro-A Thyro-AX Thyro-P Thyro-Family Thyro-S Thyro-A Thyro-AX Thyro-P STATE-OF- THE-ART- TECHNOLOGIE DIGITAL POWER CONTROLLER AEG Power Solutions presents the new Thyro-Family with the digital power controllers Thyro-S, Thyro-A,

More information

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW) Characteristics soft starter-ats22-control 220V-power 230V(110kW)/400...440V(220kW) Complementary Assembly style Function available Power supply voltage limits Main Range of product Altistart 22 Product

More information

aerl PRODUCT DATASHEET MAXIMIZER TM RANGE PRODUCT OVERVIEW COOLMAX SR - Wall Mount Australian Energy Research Labs AER G2 v5 1 February 2016

aerl PRODUCT DATASHEET MAXIMIZER TM RANGE PRODUCT OVERVIEW COOLMAX SR - Wall Mount Australian Energy Research Labs AER G2 v5 1 February 2016 PRODUCT OVERVIEW The AERL COOLMAX SR is a high efficiency, buck only, common positive Maximum Power Point Tracker (MPPT). It is the latest development in the AERL MAXIMIZER TM Range, which was pioneered

More information

Technical Manual Nova: Cabinet Security Management System (CSMS)

Technical Manual Nova: Cabinet Security Management System (CSMS) Technical Manual Nova: Cabinet Security Management System (CSMS) KP_nova_TM_160501_EN 1 Publication May, 2016, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com/nova

More information

Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F

Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F RMS Rainwater Harvesting Series 100 Controller Specifications Measurement Performance Contacting Conductivity ph Range 0-10,000 µs/cm Range -2 to 16 ph units Resolution 1 µs/cm Resolution 0.01 ph units

More information

ADXL Series SIMPLE, EFFICIENT AND SAFE MOTOR CONTROL

ADXL Series SIMPLE, EFFICIENT AND SAFE MOTOR CONTROL SOFT STARTERS ADXL Series SIMPLE, EFFICIENT AND SAFE MOTOR CONTROL Simplicity The ADXL series of soft starters is equipped with a backlit LCD icon display and NFC connectivity for quick and easy configuration,

More information

MLC 9000 Bus Compatible PID

MLC 9000 Bus Compatible PID MLC 9000 Bus Compatible PID Modbus, DeviceNet, Profibus Compatable The MLC 9000 is a unique, stand alone PID control solution to use instead of discrete DIN controllers. Reduce Wiring Costs Clean up the

More information

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers. General Information CFW10 CFW100 CFW08 CFW500 CFW700 CFW701 CFW11 EDP11 CFW11M SSW05 SSW07 GPH2 TPH2 The is WEG s third generation Soft Starter line. The keypad, with dual display, has red LED digits which

More information

Lowering Lifecycle Costs

Lowering Lifecycle Costs Lowering Lifecycle Costs with Intelligent Motor Control Centers Standards Certification Education & Training Publishing Conferences & Exhibits Speakers: Presented and Authored by Jeff M. Miller, PE, ENV

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW) Product datasheet Characteristics ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/400...440V(7.5kW) Complementary Assembly style Function available Supply voltage limits Main Range of product

More information

CD3000E-REVO E Serial Communication Manual

CD3000E-REVO E Serial Communication Manual USE S MANUAL ev. 02/2015 CD3000E-EVO E Serial Communication Manual 00005 CD Automation S.r.l. Via Picasso 34/36-20025 Legnano (MI) ITALY Tel +39 0331 577479 Fax +39 0331 579479 E-Mail: info@cdautomation.com

More information

SmartWire-DT In panel and on machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators

SmartWire-DT In panel and on machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators SmartWire-DT In panel and on machine wiring solutions Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators SmartWire-DT Changing the way panels... Reduce cost throughout

More information

Universal Motor Controller UMC22-FBP. Excellent motor protection and control ATEX ABB

Universal Motor Controller UMC22-FBP. Excellent motor protection and control ATEX ABB Universal Motor Controller UMC-FBP Excellent motor protection and control ATEX ABB FieldBusPlug: the concept ABB s communicative product family comprises a wide range of switching, controlling and automation

More information

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection Product datasheet Characteristics ATS22D75S6U Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product

More information

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter. www.sordselectric.com MA7200 Sensorless Vector AC Inverter Features and Benefits Sensorless Vector The MA7200 has precise speed and torque control for the most demanding system performance and simple set-up

More information

Table of Contents. Chapter 1: Getting Started. Chapter 2: Specifications

Table of Contents. Chapter 1: Getting Started. Chapter 2: Specifications Chapter 1: Getting Started Introduction...1 2 The Purpose of this Manual...1 2 About Getting Started...1 2 Supplemental Manuals and Other Help...1 2 Technical Support...1 2 Conventions Used...1 3 Key Topics

More information

ENGINEERED SOLUTIONS. Solutions for Any Application. us.mitsubishielectric.com/fa/en/

ENGINEERED SOLUTIONS. Solutions for Any Application. us.mitsubishielectric.com/fa/en/ ENGINEERED SOLUTIONS Solutions for Any Application us.mitsubishielectric.com/fa/en/ Engineered Solutions for Any Application Manufactured to the highest standards in UL approved facilities, the Engineered

More information

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21 Characteristics variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21 Main Range of product Product or component type Device application Device short name Variant Product destination

More information

4 LOOP MODULAR POWER CONTROLLER

4 LOOP MODULAR POWER CONTROLLER GFX- LOOP MODULAR POWER CONTROLLER Main features independent loop control unit. Compact, ready to use, equipped also with fieldbus interface. Main application Packaging Extrusion Thermoforming Injection

More information

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies ADC7520 SERIES 1600W Battery Chargers and Power Supplies Wide output adjustment range 0 72VDC Analog control by external 0-5VDC voltage Temp.comp charging, sense as on option Power fail relay alarm Master-Slave

More information

Extruder Controls ExtruVision S

Extruder Controls ExtruVision S Extruder Controls ExtruVision S ExtruVision S - The compact system solution for controlling, visualization, and operating extrusion systems Combination of control panel BA Touch with 5.7'' monitor and

More information

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications... .6 Contents Standards and Certifications............... Product Selection....................... Technical Data and Specifications........... Dimensions............................ Learn Online Page V3-T-04

More information

CLA-VAL Control Panel

CLA-VAL Control Panel Power from Flowing Water Description Integral P.I.D functions Graphics based programming Auto / Manual Control Local or Remote set point Over-rides Lockable cabinet for security Max. power consumption

More information

Revolutionizing control wiring

Revolutionizing control wiring SmartWire-DT Panel Wiring Solutions Revolutionizing control wiring 797-6925 Fax: (215) 221-1201 www.royalelectric.com SmartWire-DT Changing the way panels are wired. Reduce cost throughout the value chain.

More information

RT4F-110V/25A RECTIFIER

RT4F-110V/25A RECTIFIER The RT4F-110V/25A is a hot-pluggable switched mode rectifier (SMR) module designed to provide up to 25A of output current into a 110V nominal system. Examples of such systems are 60 cells lead acid (136V

More information

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection Product datasheet Characteristics ATS22C17Q Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product

More information

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V) E510 Compact Drive IP 20/ NEMA 1 0.5-40 HP (230V) 1-75 HP (460V) Control Mode Application & Selection Guide The E510 compact AC Drive is an easily configurable product that controls many motor driven applications.

More information

Digital multimeters DMG

Digital multimeters DMG Digital multimeters DMG 600-610 ENERGY AND AUTOMATION POWER OF ENERGY SAVING Digital multimeters DMG 600-610 are capable of viewing the measurements with high accuracy on the wide LCD display, which allow

More information