Test Asset Optimization Services Power Line Utilization Module (PLUM) DATA SHEET
|
|
- Melinda Atkinson
- 5 years ago
- Views:
Transcription
1 Test Asset Optimization Services Power Line Utilization Module (PLUM) DATA SHEET
2 Description A Power Line Utilization Module (PLUM) is a device used to monitor the utilization and health parameters of an instrument in real time. This monitoring occurs both during the instruments normal operation and during its idle time in the R&D lab or production floor. To determine instrument utilization, the PLUM measures power fluctuations over time and monitors GPIB traffic. To determine instrument health, the PLUM measures temperature, humidity, shock, current and voltage. These utilization and health parameter trends are captured and recorded in the PathWave Asset Advisor. Utilization parameter Health parameters % (minutes used / hour) Temperature Humidity Shock Current Voltage Collecting, analyzing and interpreting utilization and health data improves preventative maintenance management, avoids instrument downtime, saves time in Out-of-Tolerance (OOT) analysis, and identifies under-utilized assets. For example, maintenance and downtime can be avoided by monitoring the excessive heat, humidity or current as these can lead to an instrument failure. OOT Root Cause Analysis can take less time as the health data can provide insights when an OOT driving event occurred. Taking action on utilization and health data will reduce capital and operating expenses. The PLUM data is captured by the PathWave Asset Advisor. A PLUM device is an external module that sits in-line with the AC power supply and runs on instruments that do not have a true CPU or host controller. If there is a loss in connectivity, the PLUM collects and stores the data for one month, depending on how the data collection frequency is set. At the time of re-connection, the PLUM sends all the stored data to the PathWave Asset Advisor. As the storage capacity of the PLUM is reached, the PLUM data is overridden using a first-in first-out logic. Page 2
3 The utilization and health data is associated to a specific instrument by its unique identifier in the PathWave Asset Advisor. No measurement or device under test (DUT) data is captured by the PLUM or sent to the PathWave Asset Advisor. GPIB GPIB Controller Figure 1. PLUM shown with instrument, controller and GPIB Features Utilization To determine utilization, PLUMs measure power fluctuations captured in a % (minutes used / hour). The PLUM analyzes the GPIB traffic and registers commands sent to the assets it s connected to as utilization events. The update rate is user configurable between 5 minutes and 24 hours. Figure 2. Asset utilization of an instrument with a PLUM configured to the PathWave Asset Advisor Page 3
4 Health To determine instrument health, PLUMS have temperature, humidity, current, and voltage sensors and a three-axis accelerometer to capture physical shock data. The benefit of capturing and monitoring this information is to maximize the performance of the instrument and to reduce the risk of failure. Color Green Yellow Red Meaning Instrument performing within specification Instrument approaching specification limits and requires close monitoring Instrument performing out of specification with risk of imminent failure Figure 3. Asset Health of an instrument with a PLUM configured to the PathWave Asset Advisor Temperature The value of measuring the environmental temperature of an instrument is to ensure that the instrument is not operating at too high or too low a temperature. If the instrument is used in environments where the temperature is too high, the instrument ages prematurely, requires more frequent calibrations and experiences a higher risk of failure. If the instrument is used in environments where the temperature is too low, the instrument may require more frequent calibration to remain within specifications. Page 4
5 Humidity The value of measuring the environmental humidity surrounding the instrument is to avoid unnecessary instrument failure. If the relative humidity is too high, condensation can occur and, if the relative humidity is too low, there is the risk of static electricity, resulting in electrical shorts and instrument failure. Shock The value of measuring shock is to monitor if the instrument is dropped or if the instrument rack is jarred by human error. Sufficient shock can result in a printed circuit board losing its connection, resulting in instrument failure or incorrect measurements. Current The benefit of measuring current is to determine any significant changes in the instrument operation. If current drawn to the instrument is higher than normal, it could be an indication of a part failure. For example, the instrument fans may operate at maximum power, drawing additional current, to cool the instrument in a hot environment. Monitoring current may prevent an instrument failure. Voltage The benefit of measuring voltage is to ensure that the instrument is used within its designed specifications. Most instruments are designed to operate at some voltage tolerance near 120 or 240 Volts. If the instrument operates at too low or too high a voltage, it may permanently damage some components. Voltage measurements can monitor disruptions in the power source, such as brown-outs, so that the data would be available to alert the user to power off the instrument. Data transmission alternatives Data can be collected from the PLUM in two ways: 1 WiFi Data can be transmitted from the PLUM to PathWave Asset Advisor via WiFi network. 2 LAN Data can be transmitted from the PLUM to PathWave Asset Advisor via LAN. A hub or switch may be required with the LAN option. Page 5
6 Specifications Peripheral Interfaces WLAN b/g/n, 2.4 GHz, interior antenna Bluetooth On Board Bluetooth 4.0 module, interior antenna Ethernet 1x10/100M GPIB 1x GPIB monitor interface Sensor Temperature -40 to +85 C Humidity 0 to 100% Accelerometer ±16 G Current 10 Amps Voltage 85 to 265 VAC Power Input Wide Range ( VAC with ±10% ), C14 Terminal Consumption 1.8 W Average (without WLAN) Mechanical Dimensions 100 x 60 x 43 mm (Box) Weight 0.4 Kg Enclosure Black Plastic Environment Condition Temperature Operating: -25 to +60 C; Storage: -40 to +85 C Humidity 5 to 95% RH at 25 to 35 C (Non-Condensation) Cooling Mode No fan Safety Information Warning Statements and Symbols Caution and Warning notices are used in this document are described below. A notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a notice until the indicated conditions are fully understood and met. WARNING A WARNING denotes a hazard. It calls attention to an operating procedure, practice or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met. Page 6
7 General Safety Notices This product has been designed and tested in accordance with accepted industry standards, and has been supplied in a safe condition. The documentation contains information and warnings that must be followed by the user to ensure safe operation and to maintain the product in a safe condition. WARNING No operator serviceable parts inside. Refer servicing to qualified personnel. To prevent electrical shock do not remove covers. WARNING For continued protection against fire hazard, replace fuses, and or circuit breakers only with same type and ratings. The use of other fuses, circuit breakers or materials is prohibited. The Mains wiring and connectors shall be compatible with the connector used in the facilities electrical system. Failure, to ensure adequate earth grounding by not using the correct components may cause product damage, and serious injury. Install the instrument so that the detachable power cord is readily identifiable and is easily reached by the operator. The detachable power cord is the instrument disconnecting device. It disconnects the mains circuits from the mains supply before other parts of the instrument. This instrument has auto-ranging line voltage input;, be sure the supply voltage is within the specified range and that voltage fluctuations do not to exceed 10 percent of the nominal supply voltage. This device provides no overcurrent protection for the DUT to which it is connected. It is expected that the DUT itself will provide overcurrent protection for its circuitry. Page 7
8 Best Practices for PLUM Use Post these instructions on or near the instrument that has a PLUM attached for continuous reference. PLUM Placement Ensure that the PLUM is attached to the instrument using double sided tape and placed in a position that will not receive undue fan exhaust, jolts or bumps from near by instruments or racks. Misplacement of the PLUM could produce inaccurate or false temperature, humidity or accelerometer readings. If PLUM is not attached directly to the instrument, also ensure to avoid PLUM placement in areas receiving exhaust fan heat or potential for bumps that will produce false accelerometer readings. PLUM Placement with Wi-Fi Connectivity enabled Initial placement of the PLUM during installation was optimized for Wi-Fi signal connectivity to PathWave Asset Advisor. In case of instrument movement and the PLUM is disconnected, it is best to put the PLUM back in its original placement to ensure Wi-Fi connection is enabled. Instrument Movement Ensure the PLUM travels with the instrument if will be utilized in a different location. All PLUMs are matched to their specific instrument. If the PLUM must be disconnected, for example sending the instrument out for service, ensure that the PLUM is re-attached to the same instrument per the Asset ID# on the PLUM label. Also, follow PLUM Placement guidelines above. Instrument GPIB Address Changes Ensure that GPIB Address for the PLUM is kept constant per the PLUM label. If GPIB address must be changed contact your PathWave Asset Advisor Site Administrator to have the PLUM GPIB address re-configured. Page 8
9 Requirements PathWave Asset Advisor - Track and Control application PathWave Asset Advisor - Utilization and Health application Startup Services Related Services PathWave Asset Advisor - Application Note EN Learn more at: For more information on Keysight Technologies products, applications or services, please contact your local Keysight office. The complete list is available at: This information is subject to change without notice. Keysight Technologies, 2018, Published in USA, July 18, 2018, EN Page 9
Digital Multimeter Damage Prevention
Digital Multimeter Damage Prevention Performing measurements with a digital multimeter (DMM) is very common in today s world. Technicians use multimeters for equipment servicing, engineers use multimeters
More informationInstallation Job Aid for VSP 4850GTS
Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe
More informationInstallation Job Aid for Ethernet Routing Switch 3600 Series
Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions
More informationQUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.
PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA
More informationInstallation Job Aid for VSP 4450GTX-HT- PWR+
Installation Job Aid for VSP 4450GTX-HT- PWR+ Notices Release 6.1.0.0 NN46251-305 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs
More informationQUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!
QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationBCM2 Series Branch Circuit Monitors Quick Setup Guide
BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationPM Series Power Meter
PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See
More informationMDM 011-Z1 Regen Resistor
MDM 011-Z1 Regen Resistor Date of creation: 10.04.2017 Version date: 10.04.2017 Article number: 09-402-011-Z1-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax: 06274/4321-18
More informationRZ5/RZ5D/RZ6 Processor. Operator s Manual
RZ5/RZ5D/RZ6 Processor Operator s Manual RZ5/RZ5D/RZ6 Processor Operator s Manual Copyright 2010-2013 Tucker-Davis Technologies, Inc. (TDT). All rights reserved. No part of this manual may be reproduced
More informationOperating instructions. Speed monitor D / / 2014
Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5
More information* * Agilent Power Distribution Unit (PDU) Installation Guide
Agilent Power Distribution Unit (PDU) Installation Guide For use with Agilent PDU kits and PDU installation kits for Agilent instrument racks June 2008 Edition 7 E0608 *5000-0039* 5000-0039 Notice The
More informationInstallation Job Aid for Ethernet Routing Switch 5900 Series
Installation Job Aid for Ethernet Routing Switch 5900 Series Notices NN47211-301 Issue 05.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs
More informationPart No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A
Part No. Z1-109-820, IA001705 Jul. 2016 OPERATION MANUAL High Voltage Digitalmeter 149-10A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.
More informationRZ2 BioAmp Processor. Operator s Manual
RZ2 BioAmp Processor Operator s Manual RZ2 BioAmp Processor Operator s Manual Copyright 2008-2013 Tucker-Davis Technologies, Inc. (TDT). All rights reserved. No part of this manual may be reproduced or
More informationOperating instructions AS-i SmartLine module AC3200 AC /00 06/2016
Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target
More informationInstallation RA5112-C-16A-C20. Basic Rack Power Distribution Unit
Installation RA5112-C-16A-C20 Basic Rack Power Distribution Unit Contents Before You Begin........................1 Safety and grounding information..........1 How to Install the Rack PDU...............2
More informationPart No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A
Part No. Z1-109-820, IA001704 Mar. 2011 OPERATION MANUAL High Voltage Digitalmeter 149-10A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.
More informationLine reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4
Safety information 1 General 2 SINAMICS SINAMICS G120P Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.6 11/2013 A5E32845290B AA
More informationPart No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A
Part No. Z1-109-920, IA001723 Nov. 2005 OPERATION MANUAL High Voltage Digitalmeter 149-30A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.
More informationOperating instructions. Switching amplifier DN0210 DN / / 2015
Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5
More informationG5 PDU Installation Guide
G5 PDU Installation Guide 1 Contents Before You Begin... 3 Overview... 3 Important Safety Information... 3 Required Tools... 5 Section 1 Introduction... 6 Classification Overview... 6 Features... 7 Form
More informationThe power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.
The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings
More informationHP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions
HP UPS R/T3000 ERM Installation Instructions Overview The ERM consists of two battery packs in a 2U chassis. The ERM connects directly to a UPS R/T3000 or to another ERM. Up to two ERM units can be connected.
More informationLaboratory Switch Mode Power Supply Series. Instruction Manual
Laboratory Switch Mode Power Supply Series Instruction Manual Model 72-8340 1.0 ~ 60VDC 0 ~ 1.6A 72-8345 1.0 ~ 36VDC 0 ~ 3A 72-8350 1.0 ~ 20VDC 0 ~ 5A Copyright 2008, all rights reserved Tenma Test Equipment
More informationOperating instructions. Standstill monitor A / / 2011
Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II
More informationEC Series. Safety Guide
EC Series Safety Guide R5906018/02 01/07/2017 Barco Inc, Image Processing 3078 Prospect Park Drive, Rancho Cordova, CA, 95670, USA Phone: +1 916 859-2500 Fax: +1 916 859-2515 Support: www.barco.com/en/support
More informationInstalling the Cisco AS5400XM Universal Gateway
CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,
More informationH Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION
H Series PLC EH-150 Analog input module EH-AXH8M Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction manual and all the
More informationHITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions
HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction
More informationQUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!
QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationINSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:
DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated
More informationSafegard V4 Panel. Installation Datasheet. Safegard V4 Panel Installation Instructions and Datasheet release 1.7 August 2016
Safegard V4 Panel Installation Datasheet ELECTROSTATIC SENSITIVE DEVICE This product forms part of a life safety system. Failure to correctly store, handle, install and maintain the product will directly
More informationFirmware Guide. Keysight PXIe Chassis Family
Firmware Guide Keysight PXIe Chassis Family Notices Keysight Technologies, Inc. 2018 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or
More informationNTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY
NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY USER MANUAL Keep this manual in a safe place for quick reference at all times. This manual contains important safety and operation instructions for correct
More informationQUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter
QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices.
More informationAgilent OBSAI Protocol Tester
Agilent OBSAI Protocol Tester Hardware Reference Guide Agilent Technologies Notices Agilent Technologies, Inc. 2008 No part of this manual may be reproduced in any form or by any means (including electronic
More informationInt3233. Soldering Station. Instruction Manual
Int3233 Soldering Station Instruction Manual Thank you for purchasing the Aoyue int 3233 Soldering Station. Please read the manual before using the unit. Keep manual in accessible place for future reference.
More informationAgilent E2943A/E2944A ATCA Probes for Advanced Switching Interconnect
Agilent E2943A/E2944A ATCA Probes for Advanced Switching Interconnect Hardware Setup Guide Agilent Technologies Notices Agilent Technologies, Inc. 2005 No part of this manual may be reproduced in any form
More informationiconverter 2-Module Power Chassis
iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by
More informationSymmetra PX 160. Maintenance Bypass Enclosure. Installation 05/
Symmetra PX 160 Maintenance Bypass Enclosure Installation 05/2014 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries
More informationD610H, D610H MKII, D610S, D610T dimmer pack. user manual
D610H, D610H MKII, D610S, D610T dimmer pack user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de
More informationPlease read these instructions carefully before installing This will ensure an easy start and a great first customer experience with TS4 installation
Please read these instructions carefully before installing This will ensure an easy start and a great first customer experience with TS4 installation INTERACTIVE INSTALLATION AND SAFETY MANUAL FOR TS4:
More informationModels 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide
Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide Safety precautions Observe the following safety precautions before using this product and any associated instrumentation.
More informationAgilent 70612B K18 Switch Matrix
Agilent 70612B K18 Switch Matrix Hardware Reference Manual Agilent Technologies COPYRIGHT 2000 AGILENT TECHNOLOGIES, INC. ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED IN ANY FORM OR
More informationTPC25 active crossover. user manual
TPC25 active crossover user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 25.09.2017,
More informationInstallation and Operation Back-UPS BR1000G-IN / BR1500G-IN
Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Important Safety Information Read the instructions carefully to become familiar with the equipment before trying to install, operate, service
More informationInstalling and Configuring Rialto Analytic Appliances
Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation
More informationFHOTON WI-FI MODULE Owner's Manual
FHOTON WI-FI MODULE Owner's Manual BEFORE GETTING STARTED Read and follow safety instructions. Refer to product data plate(s) for additional operating instructions and specifications. ATTENTION IMPORTANT
More informationUV Power Flood. User Manual. Order code: EQLED029
UV Power Flood User Manual Order code: EQLED029 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CARE- FULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please make
More informationInstallation Guide SMT 2200/3000 VA Input/Output Hardwire Kit
Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit Important Safety Messages SAVE THESE INSTRUCTIONS - This section contains important instructions that should be followed during installation
More informationInnoMedia Business VoIP ATA Models
InnoMedia Business VoIP ATA Models MTA8328-4, MTA8328-8, MTA8328-24 Quick Installation Guide Important Safety Instructions Protective Earthing Protective earthing is used as a safeguard. This equipment
More informationLF3-400 Three Phase Frequency Converter, Operation and Maintenance.
Vision House. 41 Brunel Road, Churchfields Industrial Estate, St. Leonards-on-Sea East Sussex. TN38 9RT. United Kingdom Sales & Service : 01424 856 172 magnuspower.sales@akersolutions.com magnuspower.service@akersolutions.com
More informationUniversal AC Power Source + AC Power Analyzer
User's Guide Universal AC Power Source + AC Power Analyzer Model 380820 Introduction Congratulations on your purchase of the Extech Model 380820. This Universal AC Power Source and AC Power Analyzer can
More informationPV Rapid Shutdown device
PV Rapid Shutdown device Installation and Operation Manual Solis-RSD-1G(1:1) Solis-RSD-1G(2:2) Manufacturer: Ginlong (Ningbo) Technologies Co.,Ltd., Ningbo, Zhejiang, P.R.China US Office: 565 Metro Pl.
More informationLine reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation
Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.7 04/2014 A5E00331462A Legal
More informationOPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual
OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS Model Nos. OPR065-48S / OPR065-48R Manual Revision F July 2009 Optimal Power Supplies LLC www.optimal-power.com i
More information3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE
3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE -ST-01 Page 1 of 10 November 2016 2016 Copyright Lite-On Technology Corporation ALL RIGHTS RESERVED. Lite-On is a trademark of Lite-On Technology
More informationMAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS
MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...
More informationModel HM-535 Power Supply Installation and Service Instructions
Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS
More informationHCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control
HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control 1. INTRODUCTION User Manual This family of efficient, upgraded SMPS with small form factor,
More informationOperating instructions Evaluation system for flow sensors VS / / 2013
Operating instructions Evaluation system for flow sensors VS3000 7097 / 0 07 / 203 Contents Preliminary note...2 2 Safety instructions...3 3 Function and features... Mounting.... Mounting of the sensors...
More informationAutomated Tuner System Power Distribution Hub
User Guide Automated Tuner System Power Distribution Hub Model MT1020B MT1020-340 (Rev B) 12/11 User Guide Automated Tuner System Power Distribution Hub Model MT1020B 2900 Inland Empire Boulevard Ontario,
More informationSeries 8000 RF Signal Switch Solution
RF Signal Switch Solution Operation Manual Operation Manual, Part Number 07508000 006, Rev. B, Oct 7, 2014 All technical data and specifications in this publication are subject to change without prior
More informationUser's Guide. Model W 3-in-1 Switching DC Power Supply
User's Guide Model 382260 80W 3-in-1 Switching DC Power Supply Introduction Congratulations on your purchase of the Extech 80W 3-in-1 Switching DC Power Supply. The Model 382260 has three output ranges
More informationInstallation, Operation and Maintenance Manual
Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,
More informationPanel Installation Datasheet
ACTIONPAC LNS5 & SAFEGARD V5 Panel Installation Datasheet ELECTROSTATIC SENSITIVE DEVICE This product forms part of a life safety system. Failure to correctly store, handle, install and maintain the product
More informationMODEL 805 USER MANUAL
MODEL 805 USER MANUAL All Rights Reserved Page 1 of 12 UNPACKING & INSPECTION Save all packing materials they are required for returns and warranty service. Inspect the 805 and packing materials for any
More informationUTAH-100/XHDA SERIES
Utah Sandar AS User Manual & Installation Guide UTAH-100/XHDA SERIES SD & HD3G Digital Distribution 1:4 & 1:8 CONTENTS CONTENTS... 2 INTRODUCTION... 3 WARRANTY... 3 DOCUMENT REVISION HISTORY... 3 SAFETY
More informationD1210H dimmer pack. user manual
D1210H dimmer pack user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 13.08.2015,
More informationSeries 8000 RF Signal Switch Solution
RF Signal Switch Solution Operation Manual Operation Manual, Part Number 07508000-006, Rev. A, May 17, 2013 All technical data and specifications in this publication are subject to change without prior
More informationObtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx
Preface Obtaining Documentation and Submitting a Service Request, page xvii Safety s, page xvii Safety Guidelines, page xx Obtaining Documentation and Submitting a Service Request For information on obtaining
More informationPR3400 Series 1.4Mp USB Cameras Hardware Guide
PR3400 Series 1.4Mp USB Cameras Hardware Guide Manufactured by: SPOT Imaging Solutions, a division of Diagnostic Instruments, Inc. 6540 Burroughs Ave. Sterling Heights, MI 48314-2133 USA Toll-Free: 866-604-SPOT
More informationGirard Awnings R ACMC Motor Controller (Last revised on May 10, 2008) A Visionary Awning Control by
Girard Awnings R ACMC Motor Controller (Last revised on May 10, 2008) R A Visionary Awning Control by Girard AC Motor Controller Installation Guide ACMC Revision 2.08 May 10, July 2008 ACMC Installation
More informationModel 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 8020-KHV Kelvin Keithley Triaxial Connector Card Description The Model 8020-KHV Keithley HV Connector
More informationADC7520 SERIES. 1600W Battery Chargers and Power Supplies
ADC7520 SERIES 1600W Battery Chargers and Power Supplies Wide output adjustment range 0 72VDC Analog control by external 0-5VDC voltage Temp.comp charging, sense as on option Power fail relay alarm Master-Slave
More informationErrata. Agilent References in this manual. About this manual. Support for your product
Errata Agilent References in this manual NOTICE: This document contains references to Agilent Technologies. Agilent s former Test and Measurement business has become Keysight Technologies. For more information,
More informationLVN5200A-R2, rev. 1, Hardware Installation Guide
LVN5200A-R2 LVN5250A-R2 LVN5200A-R2, rev. 1, Hardware Installation Guide Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support
More informationInstalling the IPS 4345 and IPS 4360
CHAPTER 4 Installing the IPS 4345 and IPS 4360 Contents This chapter describes the Cisco IPS 4345 and the IPS 4360, and includes the following sections: Installation Notes and Caveats, page 4-1 Product
More informationDPX-620III 6-Ch. dimmer pack. user manual
DPX-620III 6-Ch. dimmer pack user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 28.08.2017,
More informationInstalling the Cisco ATA
CHAPTER 2 This section provides instructions for installing the Cisco ATA 186 and Cisco ATA 188. Before you perform the installation, be sure you have met the following prerequisites: Planned the network
More informationOmnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual
Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,
More informationBS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0
BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY
More informationInstallation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules
Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules This document provides the installation and removal instructions for the AC and DC input power supply and fan modules
More informationWa r n i n g-wa r n i n g-wa r n i n g
Installation Instructions of the Power Analyzer Wa r n i n g-wa r n i n g-wa r n i n g Read and understand this manual before connecting device. Death, fire or serious injury can occur from using equipment
More informationELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS
ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE 1. Circuit Breaker Tripping 2. Circuit Overload 3. Short Circuit 4. Ground Fault 5. Ground Fault Circuit Interrupter (GFCI) Tripping SAFETY PRECAUTIONS Basic
More informationInstallation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL
Model name: BMS-LSV6UL INTELLIGENT SERVER Thank you very much for purchasing this TOSHIBA INTELLIGENT SERVER. Please read this manual carefully beforehand for proper installation of the SERVER. NOTE This
More informationFeatures: Example of use
RS64 v1.0 RS64 6-ports switch with power supply for 4 IP cameras, RACK Edition: 1 from 10.01.2018 Supercedes the edition: ---------- EN** Features: Switch 6 ports 4 PoE ports 10/100Mb/s (data transfer
More informationOPERATOR S MANUAL 9000U ISOLATOR
OPERATOR S MANUAL 9000U ISOLATOR Masibus Automation And Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Ph: 91 79 23287275-79 Fax: 91 79 23287281,
More informationGE Digital Energy. Power Quality
GE Digital Energy Power Quality INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Enhanced Thermal Protection (ETP) Series Wall Mounted Medium and High Exposure Surge Protective Devices (SPDs)
More informationMini Digital Multimeter
User Manual Mini Digital Multimeter Model MN15A Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech MN15A MultiMeter. The MN15A offers
More informationP216. Condenser fan speed controller. Product bulletin. Features
P216 Condenser fan speed controller Product bulletin These controllers are designed for speed variation of single phase motors, especially for fan speed control on air cooled condensers. Head pressure
More informationCrossfire. User Manual. Order code: EQLED061
Crossfire User Manual Order code: EQLED061 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please make sure
More informationOwner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series
Owner s Manual 19 Pro Series Rack Mount (RK) Faceplate Isolate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) Colours Restore. Power Conditioners Audio / Video Power Isolation
More informationINSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1
INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1 TOSHIBA Corporation 2004 All Rights Reserved. ( Ver. 1.6 ) Safety Precautions Before using this product, please read this chapter carefully. This
More informationEOS-6000 Series Optical A/B Switch User Manual DC Version
EOS-6000 Series Optical A/B Switch User Manual DC Version For more information on this and other products: Contact Sales at EMCORE 626-293-3400, or visit www.emcore.com. Table of Contents Table of Contents...2
More informationATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318
ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16
More informationInstallation and Operations Manual. Electronic copies available at (Rev_ )
Installation and Operations Manual Electronic copies available at www.aquariitech.com/downloads/axceleronmanual Axceleron Installation and Operations Manual AXCELERON FIXTURE INSTALLATION... 1 Introduction...
More informationSmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs
MAN0969-02 PAGE 1 Mix577/977 Module ` SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs 1 SPECIFICATIONS Analog Inputs High Resolution Steady State Current 120mA @ 24v
More informationDS-1H05 Ethernet-over-Coax Extender. User Manual
DS-1H05 Ethernet-over-Coax Extender User Manual Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to DS-1H05-T,
More information