ABPM. Operating Manual. Part 2: Hardware, description of device for custo screen 300/400/pediatric

Size: px
Start display at page:

Download "ABPM. Operating Manual. Part 2: Hardware, description of device for custo screen 300/400/pediatric"

Transcription

1 Operating Manual ABPM 1 Safety Hardware 3 Software 4 Hygiene Part : Operating characteristics: For automatic ABPM measurements lasting up to 7 hours MHW 0005 DK 1664 Version 001 1/01/018

2 018 custo med GmbH This Operating Manual may not be copied in its entirety or in part, duplicated in any form or by any means or translated into another language without the prior written consent of custo med GmbH. The manufacturer reserves the right to change the information in this Operating Manual without prior notice. The current version can be downloaded from our website: CAUTION: This Operating Manual is part of a modular system, consisting of four parts. All four parts must be downloaded from the Internet or from a CD to ensure the Operating Manual is complete. MHW 0005 DK 1664 Version 001 1/01/018 custo med GmbH [] ABPM Hardware, custo screen 300/400/pediatric page

3 Operating Manual ABPM 1 Safety Hardware 3 Software 4 Hygiene Part : Table of contents.1 Symbols on the devices Intended use..1 custo screen 300/ custo screen pediatric Part names, components for the recording Device operation.4.1 custo screen 300/400/pediatric recorder Elements in the display Error codes and their causes Attaching the recorder to the patient Patient instructions Technical data and system requirements Manufacturer s declaration regarding EMC EC Declaration of Conformity List of product components and accessories MHW 0005 DK 1664 Version 001 1/01/018 custo med GmbH [] ABPM Hardware, custo screen 300/400/pediatric page 3

4 ABPM.1 Symbols on the devices Manufacturer: custo med GmbH, Maria-Merian-Str. 6, 8551 Ottobrunn, Germany CE mark Safety class classification of medical electrical equipment according to DIN EN (Type BF) custo screen 300/400: The device is suitable for children aged ten and older (not for newborns and small children). custo screen pediatric: The device is suitable for children aged between three and twelve years (not for newborns and small children). Non-ionising electromagnetic radiation, device contains an RF transmitter (the radio unit of custo screen 300 is not active) Symbol on the custo screen 400 recorder for the insertion direction of the mini SD card (custo flash card mini) The sticker specifies the date when the next metrological check is due. Contact your authorised custo med dealer Ottobrunn MTK gültig bis: Observe the Operating Manual Separate collection of electrical and electronic equipment, do not dispose with domestic waste MHW 0005 DK 1664 Version 001 1/01/018 custo med GmbH [] ABPM Hardware, custo screen 300/400/pediatric page 4

5 . Intended use..1 custo screen 300/400 custo screen 300/400 is an ABPM recorder with an internal power supply which is used to record and evaluate the blood pressure behaviour of a patient. The recording time can last for up to 7 hours. custo screen 300/400 is perfectly safe for use by patients with a pacemaker. The system is intended for use by trained specialist staff or physicians in clinics and medical practices. Patients are only allowed to use the recording device after receiving instruction by trained specialist staff. Patients who are not capable of understanding and following the instructions given are not allowed to use the device. This applies in particular to senile patients or patients suffering from dementia. The device is not suitable for unsupervised use with unconscious patients... custo screen pediatric custo screen pediatric is an ABPM recorder with an internal power supply which is used to record and evaluate the blood pressure behaviour of children. The recording time can last for up to 7 hours. custo screen pediatric is intended for use by general practitioners and medical specialists and also designed for hospitals and clinics. custo screen pediatric is intended for use on children 1). The device is not suitable for newborns and small children (patients must be aged at least: 3 years). 1) Definition according to DIN EN :016-0: Newborns < 1 month Toddlers < 3 years Children > 3 years Before an examination can be carried out, a physician's approval must be obtained and one of the parents must have received detailed instruction by trained specialist staff. The device must not be used for recordings on child patients who are not able to endure the examination. The device is not suitable for unsupervised use with unconscious patients. It is only permitted to carry out an examination if it is ensured that the child patient is supervised during the entire period of recording as there is a risk of strangulation. MHW 0005 DK 1664 Version 001 1/01/018 custo med GmbH [] ABPM Hardware, custo screen 300/400/pediatric page 5

6 .3 Part names, components for the recording custo screen 300/400/pediatric ABPM recorder (custo screen pedriatric featuring child-friendly motifs on the battery compartment cover, see the illustrations on the right) Cuff with retainer standard, additional cuff sizes are available, see Chapter.7 Technical data and system requirements and.10 List of product components and accessories Carrying case for the ABPM recorder Carrying belt, depending on the type of recorder in different lengths: custo screen 300/400: 17 cm, optionally 155 cm long custo screen pediatric: Child belt 96 cm Batteries (set of 3) Mignon 1.5 Volt, type AA custo com IR infrared interface USB extension cable.0, type B mini,.0 m MHW 0005 DK 1664 Version 001 1/01/018 custo med GmbH [] ABPM Hardware, custo screen 300/400/pediatric page 6

7 Tip: custo screen protect hygiene set Six washable fleece pads for more hygiene and comfort when wearing the blood pressure cuff. Worn underneath the cuff with the soft side on the skin. MHW 0005 DK 1664 Version 001 1/01/018 custo med GmbH [] ABPM Hardware, custo screen 300/400/pediatric page 7

8 .4 Device operation.4.1 custo screen 300/400/pediatric recorder Inserting the batteries or rechargeable batteries Open the battery compartment as depicted and insert three commercially available batteries. The direction of insertion is shown on the illustrations in the battery compartment. Functional elements of the device On/off switch: for switching the recorder on and off I = on 0 = off Infrared interface for transmitting data between custo screen 300/400/pediatric and PC Cuff port (BNC) Card slot for mini SD card (only with custo screen 400) Function key for starting and stopping measurements Display for displaying results and messages MHW 0005 DK 1664 Version 001 1/01/018 custo med GmbH [] ABPM Hardware, custo screen 300/400/pediatric page 8

9 .4. Elements in the display Sys: Systolic blood pressure Dia: Diastolic blood pressure P: Pulse Battery: Lights up if the batteries are weak If the blood pressure measurement has been carried out successfully... systole, diastole and pulse will be displayed three times in succession During the data transmission between the recorder and the PC... "PC" is shown on the display (the light-emitting diode of the custo com IR infrared interface flashes) In the event of erroneous measurements... an error code is shown on the display, e.g. "E06" MHW 0005 DK 1664 Version 001 1/01/018 custo med GmbH [] ABPM Hardware, custo screen 300/400/pediatric page 9

10 .4.3 Error codes and their causes Error when reading or writing the time Internal electric double-layer capacitor (energy store for the time) discharged Insert batteries, switch device on Thresholds are fallen below or exceeded Sys: < 70 mmhg > 70 mmhg, Dia: < 40 mmhg > 155 mmhg Sys - Dia: < 15 mmhg HR: < 35/min > 0/min Measurement is repeated automatically Pressure discharge rate outside the given limits Valve is leaking or defective Customer service Disturbed measurement Too many movement artefacts Cuff slipped or not tight enough Attach the cuff carefully and keep the arm steady during the measurement Battery voltage too low Insert new batteries or freshly charged rechargeable batteries into the recorder Pressure sensors transmit different values Cuff tube kinked BNC port at the recorder or cuff tube dirty One of the pressure sensors is faulty Remove cuff from device, connect it again and repeat procedure If the error persists, call customer service Pressure increase is too slow Cuff is not connected or cuff/valve is leaking/defective Connect cuff if necessary Check cuff (sealing ring in connection present/ok?) If the error persists, call customer service MHW 0005 DK 1664 Version 001 1/01/018 custo med GmbH [] ABPM Hardware, custo screen 300/400/pediatric page 10

11 Pressure increase is too fast Cuff tube is kinked, valve system is clogged Align the cuff tube If the error persists, call customer service Discharge period is too long Cuff tube is kinked, valve is defective Customer service if multiple occurrences during a recording Error when determining diastole Cuff attached incorrectly, marking is not situated on the artery, movement artefacts Attach the cuff carefully and keep the arm steady during the measurement Error when determining systole Cuff attached incorrectly, marking is not situated on the artery, movement artefacts Attach the cuff carefully and keep the arm steady during the measurement In the event of an erroneous measurement, the measurement is repeated after two minutes. If errors occur that are not listed here, switch the device off and back on again. Repeat the desired step. If the error persists, contact your authorised custo med dealer. MHW 0005 DK 1664 Version 001 1/01/018 custo med GmbH [] ABPM Hardware, custo screen 300/400/pediatric page 11

12 .5 Attaching the recorder to the patient Attaching the blood pressure cuff Make sure to select the correct cuff size for the patient. Each cuff contains information for which arm circumference it is suited, e.g. standard 4 3 cm. Attach the cuff to the left upper arm, two to three centimetres above the crook of the arm. Apply the cuff in such a way that the marking is situated on the brachial artery. The cuff must not be attached too firmly. It should still be possible to fit approximately two fingers between the arm and the cuff. Lay the cuff tube from the left shoulder over the right shoulder to the right hip. There the recorder will be placed later. Fix the cuff and the tube to the patient s body. This serves to avoid erroneous measurements due to incorrect positioning of the cuff or tube. Use professional fixing aids with a low level of adhesive residues. Attaching the belt with the carrying case Attach the carrying case to the carrying belt. Put the carrying belt on the patient. The case should be positioned on the patient s right hip. Put the switchedon recorder into the carrying case and close it with the hook and loop fastener. Connect the cuff tube to the recorder as illustrated. Sample measurement Press the function key in order to carry out a sample measurement. Take care that the patient keeps still during the measurement. In the event of an erroneous measurement, improve the fitting of the cuff and the tube. If the sample measurement is successful, patient and recorder are ready for recording. MHW 0005 DK 1664 Version 001 1/01/018 custo med GmbH [] ABPM Hardware, custo screen 300/400/pediatric page 1

13 .6 Patient instructions Handling of the recorder The day on which the recording is made should be planned as normally as possible (no day off, no exceptional events). The switched-on recorder and the cuff must also be worn during the night. No x-rays must be taken on the day of recording. Sources of interference, such as stimulation current devices, are to be avoided. Each measurement is announced with a beep (unless this function is deactivated in custo diagnostic). Using default settings, the measurements are performed every 15 minutes during the day and every 30 minutes during the night. The recorder must be protected against extreme cold, heat, moisture, dirt and mechanical impact. No showers, no visits to the swimming pool and sauna. The patient is not allowed to remove the batteries or rechargeable batteries or modify the device in any way. Do not leave small children unattended with the device. Risk of strangulation with provided cables and belts, risk of suffocation from small parts that could be swallowed. Avoiding erroneous measurements The patient must keep still during the measurement. The cuff tube must not be kinked. A repeat measurement is automatically performed two minutes after an erroneous measurement. If several measurements are erroneous (especially E6, E1-4 and E5-8), it should be checked if the cuff is still positioned correctly. The marker should be located on the brachial artery and the cuff should be positioned on the arm so that approximately two fingers fit between the cuff and the arm. For further causes of erroneous measurements, see Chapter.4.3 Error codes and their causes Discomfort during the recording If the patient experiences discomfort during a recording, e.g. caused by a too high cuff pressure, the patient must contact his/her physician. The patient can stop the measurements at any time by pressing the function key or by opening the cuff s hook and loop fastener. Pregnant women should consider their individual physical endurance and contact their physician, if necessary. MHW 0005 DK 1664 Version 001 1/01/018 custo med GmbH [] ABPM Hardware, custo screen 300/400/pediatric page 13

14 .7 Technical data and system requirements custo screen 300/400/pediatric Measurement method Measuring range Oscillometric measurement procedure, Automatic zero balancing custo screen pediatric Heart rate 35 0 beats / min Systolic blood pressure mmhg Diastolic blood pressure mmhg Measurement accuracy [mmhg] custo screen 300/400 Heart rate 35 0 beats / min Systolic blood pressure mmhg Diastolic blood pressure mmhg custo screen pediatric Systole Diastole Deviation from the average value Standard deviation 3 3. custo screen 300/400 Systole Diastole Deviation from the average value Standard deviation Meets the requirements of the ESH International Protocol 010 Max. number of measurements 500 Max. recording time 7 hours for ABPM recordings 4 hours for Holter ABPM recordings (custo screen 400) Duration of one measurement approx. 30 seconds Measuring intervals Can be set to 5 to 90 minutes in the software Standard: every 15 minutes during the day, every 30 minutes at night Cuff pressure custo screen pediatric max. 00 mmhg custo screen 300/400 max. 300 mmhg pediatric 300/400 Cuff sizes Cuff with retainer standard 4 3 cm and compatibility with the Cuff with retainer x-large 3 40 cm recorder types Cuff with retainer xx-large cm Bandage cuff pediatric 14 0 cm Bandage cuff small, child 0 4 cm Bandage cuff standard 4 3 cm Bandage cuff xx-large cm Data transmission Infrared interface with USB port (IrDA standard) mini SD card for Holter ABPM (custo screen 400) Power supply 3 Mignon 1.5 V, type AA 3 rechargeable batteries, Ni-MH, 1. V, min mah MHW 0005 DK 1664 Version 001 1/01/018 custo med GmbH [] ABPM Hardware, custo screen 300/400/pediatric page 14

15 Operating conditions Temperature +10 C C Air humidity % rh Air pressure hpa Transport and storage Temperature -0 C C conditions Air humidity % rh Air pressure hpa Dimensions Size approx. 100 * 66 * 6 mm (L * W * H) Weight approx. 159 g (without batteries) Classification Device with internal power supply Type BF Class IIa Applied standards DIN EN , DIN EN , IEC , DIN EN, , Directive 93/4/EEC MHW 0005 DK 1664 Version 001 1/01/018 custo med GmbH [] ABPM Hardware, custo screen 300/400/pediatric page 15

16 General system requirements Operating system Windows 7 SP1 with current updates (3 bit and 64 bit operating system) Windows 8 (3 bit and 64 bit operating system) Windows 8.1 (3 bit and 64 bit operating system) Windows 10 (3 bit and 64 bit operating system) Windows Server 003 (3 bit and 64 bit operating system) Windows Server 008 (3 bit and 64 bit operating system) Windows Server 008 R Windows Server 01 Windows Server 01 R older versions are not supported PC The PC hardware should meet the minimum requirements of the operating system used. Provide additional RAM (1 GB) for custo diagnostic. Please ensure that there is sufficient free space on the hard disk for the custo diagnostic evaluations. The PC must meet the requirements of the safety standard DIN EN for information technology equipment. File sizes of the evaluations Holter approx. 15 MB (max. 60 MB) ABPM: approx. 18 KB (max. 51 KB) Holter ABPM: approx. 0 MB (max. 5 MB) Resting ECG: approx. 00 KB (for an ECG of approx. 10 sec.) Stress ECG: approx. 6 MB (for an ECG of approx. 0 min.) CPET: refer to stress ECG Spirometry: approx. 50 KB (max. 56 KB) Rehab: approx. 6 MB (for approx. 45 min. of exercise) MCT: approx MB for 4-hour ECG Hardware & ports DVD or CD-ROM drive, USB port MHW 0005 DK 1664 Version 001 1/01/018 custo med GmbH [] ABPM Hardware, custo screen 300/400/pediatric page 16

17 Recommended system requirements Computer Intel Core i3-cpu with HD graphics GB RAM 56 GB SSD or SSHD (for single-position systems TB HDD) 1 GBit network connection (not for single-position systems) Fanless Dual-DVI (or DP) graphics card (for CPET) Windows 8.1 x64 (PRO version for joining a domain) Ports One USB.0 port per USB device (preferably not USB 3.0) One COM port each for ergometer and treadmills (serial) At least Version 4.0 if Bluetooth is installed otherwise can be deactivated in the BIOS Monitor 0 TFT with DVI or DP port Full HD resolution Dual-TFT for spiroergometry Printer 600 dpi Monochrome (colour recommended for CPET) USB.0 port or network connection PCL-enabled (increases printing speed with the suitable driver) MHW 0005 DK 1664 Version 001 1/01/018 custo med GmbH [] ABPM Hardware, custo screen 300/400/pediatric page 17

18 .8 Manufacturer's declaration regarding EMC (electromagnetic compatibility) according to DIN EN :007 Manufacturer's declaration electromagnetic emissions The custo screen 300/400/pediatric ABPM recorder is designed for use in the electromagnetic environment stated below. The customer or user of the custo screen 300/400/pediatric should make sure that it is used in such an environment. Emission measurements RF emissions according to CISPR11 custo screen 300 custo screen pediatric RF emissions according to CISPR11 custo screen 400 (no electromagnetic energy is emitted during ABPM recordings, only during Holter ABPM recordings with a radio connection to the ECG transmitter) RF emissions according to CISPR11 Harmonics according to IEC Voltage fluctuations/flickers according to IEC Compliance Group 1 custo screen 300 custo screen pediatric Group custo screen 400 during Holter ABPM recordings Class B Not applicable Not applicable Electromagnetic environment - guidelines custo screen 300 / custo screen pediatric uses RF energy only for its internal function. Its level of RF emission is therefore very low and is unlikely to be sufficient to interfere with other electronic devices. custo screen 400 must emit electromagnetic energy in order to perform its intended function. Other electronic devices in the vicinity may be affected. custo screen 300/400 is designed for use in all establishments, including domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes. Manufacturer s declaration electromagnetic immunity The custo screen 300/400/pediatric ABPM recorder is designed for use in the electromagnetic environment stated below. The customer or user of the custo screen 300/400/pediatric should make sure that it is used in such an environment. Immunity tests Electrostatic discharge (ESD) according to IEC IEC test level Compliance level ± 6 kv contact discharge ± 8 kv air discharge Electromagnetic environment - guidelines ± 6 kv contact discharge ± 8 kv air discharge Floors should be made of wood or concrete or be equipped with ceramic tiles. If the floor is provided with synthetic material, the relative air humidity must be at least 30 %. Fast transient electric interference factors/bursts according to IEC Surges according to IEC ± kv for net wires ± 1 kv for input and output wires ± 1 kv push-pull voltage ± kv push-push voltage Not applicable The quality of the supply voltage should correspond to that of a typical business or clinical environment. Not applicable The quality of the supply voltage should correspond to that of a typical business or clinical environment. Voltage drops, short-time interruptions and fluctuations in the supply voltage according to IEC < 5 % U T for 0.5 periods (> 95 % drop) 40 % U T for 5 periods (60% drop) 70 % U T for 5 periods (30% drop) < 5 % U T for 5 s (> 95 % drop) 3 A/m Not applicable The quality of the supply voltage should correspond to that of a typical business or clinical environment. If the user of the custo screen 300/400 requires continued operation, even if interruptions in the energy supply occur, it is recommended to supply the custo screen 300/400 from an uninterruptible power supply. Magnetic field with supply frequency (50/60 Hz) according to IEC A/m Magnetic fields with mains frequency should correspond to the typical values of a business and clinical environment. COMMENT: U T is the alternating supply voltage prior to application of test levels MHW 0005 DK 1664 Version 001 1/01/018 custo med GmbH [] ABPM Hardware, custo screen 300/400/pediatric page 18

19 Manufacturer s declaration electromagnetic immunity The custo screen 300/400/pediatric ABPM recorder is designed for use in the electromagnetic environment stated below. The customer or user of the custo screen 300/400/pediatric should make sure that it is used in such an environment. Immunity tests IEC test level Compliance level Electromagnetic environment - guidelines Portable and mobile radio sets should not be used at a closer distance to the device including the leads than the recommended protective distance which is determined according to the equation of transmitting frequency. Recommended protective distance: Conducted RF disturbances according to IEC V effective value 150 KHz to 80 MHz [U 1 ] V Not applicable d = (3.5/U1) P d = (3.5/E 1 ) P 80 MHz to 800 MHz Radiated RF disturbances according to IEC V/m 80 MHz to.5 GHz 3 V/m d = (7/E 1 ) P 800 MHz to.5 GHz with P as the nominal power of the transmitter in watt (W) according to the indications of the transmitter manufacturer and d as the recommended protective distance in meters (m). According to an examination on site a) the field strength of stationary radio transmitters should be lower than the compliance level with regard to all frequencies. In the vicinity of devices carrying the following symbol, interference is possible: COMMENT 1: With 80 MHz and 800 MHz the higher frequency range is valid. COMMENT : These guidelines may not apply in every case. The propagation of electromagnetic variables is influenced by absorptions and reflections of buildings, objects and people. a) The field strength of stationary transmitters, such as e.g. base stations of mobile phones and land mobile radios, amateur radio stations, AM and FM broadcasting as well as television networks cannot be exactly predetermined theoretically. In order to determine the electromagnetic environment regarding the stationary transmitters, a study of the location should be considered. If the measured field strength exceeds the abovementioned compliance levels at the location where the device is used, the device should be watched in order to prove the intended functions. If unusual performance features are observed, it may be necessary to take additional measures, for example reorienting or relocating the device. MHW 0005 DK 1664 Version 001 1/01/018 custo med GmbH [] ABPM Hardware, custo screen 300/400/pediatric page 19

20 Recommended protective distances between portable and mobile RF telecommunication devices and custo screen 300/400/pediatric custo screen 300/400/pediatric is designed for operation in an electromagnetic environment in which the RF transients are controlled. The user can help avoid electromagnetic interference by maintaining the minimum distance between portable and mobile RF telecommunication devices (transmitters) and the device depending on the power output of the communication device, as indicated below. Protective distance depending on the transmitting frequency in m Nominal power of the transmitter 150 khz to 80 MHz 80 MHz to 800 MHz 800 MHz to.5 GHz W d= (3.5/U1) P d= (3.5/E 1 ) P d= (7/E 1 ) P 0.01 Not applicable Not applicable Not applicable Not applicable Not applicable For transmitters whose maximum nominal power is not indicated in the above table, the recommended protective distance d can be determined in meters (m), using the equation affiliated with the corresponding column. P is the maximum nominal power of the transmitter in watt (W) according to the indications of the manufacturer of the transmitter. COMMENT 1: With 80 MHz and 800 MHz the higher frequency range is valid. COMMENT : These guidelines may not apply in every case. The propagation of electromagnetic variables is influenced by absorptions and reflections of buildings, objects and people. MHW 0005 DK 1664 Version 001 1/01/018 custo med GmbH [] ABPM Hardware, custo screen 300/400/pediatric page 0

21 .9 EC Declaration of Conformity MHW 0005 DK 1664 Version 001 1/01/018 custo med GmbH [] ABPM Hardware, custo screen 300/400/pediatric page 1

22 MHW 0005 DK 1664 Version 001 1/01/018 custo med GmbH [] ABPM Hardware, custo screen 300/400/pediatric page

23 .10 List of product components and accessories Set no. Set name Part no. Qty. Set/product designation custo screen custo screen 400 recorder Cuff standard with retainer blue 0011/C 1 Carrying belt standard 17 cm Neoprene carrying case for blood pressure recorder ) 1 SD card mini GB incl. adapter 003 1) 3 Batteries AA LR6 Mignon 1.5 Volt custo ECG set 3 K Only for Holter ABPM with custo screen custo guard /R custo belt 3 red custo belt 1/3 red extender custo charger single T 1 Power supply unit with four switch plugs custo guard 3 ECG cable 55551/Z 1 Adjustable neck strap (for custo guard 3 ECG cable and custo flash 5xx) 1169 Starter kit for custo screen combi Only for Holter ABPM with custo screen ) 1 Card reader USB.0 incl. micro USB cable USB connection cable custo com IR infrared interface custo screen custo screen 300 recorder Cuff standard with retainer blue 0011/C 1 Carrying belt standard 17 cm Neoprene carrying case for blood pressure recorder 003 1) 3 Batteries AA LR6 Mignon 1.5 Volt custo screen pediatric custo screen pediatric recorder Cuff with retainer standard Bandage cuff small, child Bandage cuff pediatric 0015/C 1 Carrying belt for children 96 cm Neoprene carrying case pediatric Battery compartment cover set for screen pedriatric 003 1) 3 Batteries AA LR6 Mignon 1.5 Volt 1170 Starter kit for custo COM IR USB connection cable custo com IR infrared interface 1) The part numbers of the IT accessories or consumables may change. MHW 0005 DK 1664 Version 001 1/01/018 custo med GmbH [] ABPM Hardware, custo screen 300/400/pediatric page 3

24 Accessories Part no. Set/product designation Blood pressure cuffs 3070 Cuff with retainer standard 307 Cuff with retainer x-large 3073 Cuff with retainer xx-large 3071 Bandage cuff small, child 3075 Bandage cuff standard 3076 Bandage cuff xx-large 3078 Bandage cuff pediatric 3077 custo screen protect hygiene set: Six fleece pads for custo med blood pressure cuffs in the sizes standard, XL, XXL and a washing bag Carrying belts 0011/C Carrying belt standard 17 cm 001/C Carrying belt long 155 cm 0015/C Carrying belt for children 96 cm Carrying cases 3060 Neoprene carrying case for blood pressure recorder 3066 Neoprene carrying case pediatric for blood pressure recorder Recorder parts Battery compartment cover set for screen pedriatric (4 motifs) ECG accessories Only for Holter ABPM with custo screen ) SD card mini GB incl. adapter 1011 ECG cable guard /Z Adjustable neck strap (for custo guard 3 ECG cable and custo flash 5xx) Adapter set for custo guard 3: Cable adapter for adhesive electrodes Coding rings for cable adapter and guard Neck strap for custo guard case 3064 Carrying case for custo guard 1011 Cable adapter set for adhesive electrodes for custo guard 3: Cable adapter for adhesive electrodes Coding rings for cable adapter and guard /R custo belt 3 red custo belt 1/3 red extender 3064 custo guard carrying case when using cable adapters 3065 Neck strap for custo guard carrying case custo charger single set: custo charger single T Power supply unit with four switch plugs 1601 micro USB cable.0, A-plug, 1.5 m for custo kybe, watch, charger 1) The part numbers of the IT accessories or consumables may change. MHW 0005 DK 1664 Version 001 1/01/018 custo med GmbH [] ABPM Hardware, custo screen 300/400/pediatric page 4

25 Manufacturer's contact details: custo med GmbH Maria-Merian-Straße Ottobrunn Germany Phone: +49 (0) Fax: +49 (0) info@customed.de Internet:

Spirometry. Operating Manual. Part 2: Hardware, description of device for custo spiro mobile

Spirometry. Operating Manual. Part 2: Hardware, description of device for custo spiro mobile Operating Manual Spirometry 1 Safety Hardware 3 Software 4 Hygiene Part : Operating characteristics: A spirometry testing device for the evaluation of pulmonary function MHW 0009 DK 1690 Version 001 17/01/018

More information

Resting and Stress ECG

Resting and Stress ECG Operating Manual Resting and Stress ECG 1 Safety Hardware 3 Software 4 Hygiene Part : Operating characteristics: 1-channel PC ECG, Resting & stress ECG MHW 0013 - DK 1716 Version 001-3/0/018 018 custo

More information

Resting and Stress ECG

Resting and Stress ECG Operating Manual Resting and Stress ECG 1 Safety Hardware 3 Software 4 Hygiene Part : Operating characteristics: 1-channel PC ECG, Resting & stress ECG MHW 001 DK 1713 Version 00 09/05/018 018 custo med

More information

Technical Specifications Micromedical VisualEyes 515 VisualEyes 525 by Interacoustics

Technical Specifications Micromedical VisualEyes 515 VisualEyes 525 by Interacoustics VisualEyes 515 and VisualEyes 525 - Technical Specifications Page 0 Technical Specifications Micromedical VisualEyes 515 VisualEyes 525 by Interacoustics D-0109757-B 2017/05 VisualEyes 515 and VisualEyes

More information

#

# INSTALLATION MANUAL Contents Getting To Know Your AVANT HIT+ TM... 3 Setting up the System... 4 Software Installation... 5 Driver Installation Windows 7... 8 Driver Installation Windows XP... 11 Accessories...

More information

measurement device with built-in Blood Pressure targets. Instruction Manual

measurement device with built-in Blood Pressure targets. Instruction Manual measurement device with built-in Blood Pressure targets. Instruction Manual EN 1 recommended guidelines of the European Society of Hypertension (ESH) 1, American Heart Association (AHA) 2 3, American Diabetes

More information

CDRPan. User Guide FOR PANORAMIC SYSTEMS. Schick Technologies, Inc th Avenue Long Island City, New York 11101

CDRPan. User Guide FOR PANORAMIC SYSTEMS. Schick Technologies, Inc th Avenue Long Island City, New York 11101 CDRPan FOR PANORAMIC SYSTEMS User Guide Schick Technologies, Inc. 31-00 47 th Avenue Long Island City, New York 11101 (718) 937-5765 (718) 937-5962 (FAX) Part Number B1051008 Rev. B Copyright 2004 by Schick

More information

Site~Rite Prevue Ultrasound System and Site~Rite Prevue+ Ultrasound System Technical Manual

Site~Rite Prevue Ultrasound System and Site~Rite Prevue+ Ultrasound System Technical Manual Site~Rite Prevue Ultrasound System and Site~Rite Prevue+ Ultrasound System Technical Manual 9770088 System Technical Manual 3 Table of Contents Section 1 Statement of Purpose 2 2.1 2.2 2.3 System Overview

More information

WM+PD Digital Sphygmomanometer

WM+PD Digital Sphygmomanometer WM+PD4001163 Digital Sphygmomanometer 1. Dear Customers Congratulations on purchasing a state-of-the-art A&D sphygmomanometer, one of the most advanced monitors available on the market today. Designed

More information

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Arm Cuff. Model HEM-711AC

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Arm Cuff. Model HEM-711AC INSTRUCTION MANUAL Automatic Blood Pressure Monitor with Arm Cuff Model HEM-711AC ENGLISH ESPAÑOL CONTENTS Before Using the Monitor Introduction..........................................2 Important Safety

More information

#0086.

#0086. Contents Getting to Know Your AVANT REM series... 3 Computer Requirements...... 4 Avant REM+.. 5 Avant REMsp.. 6 Transducer and Accessories 7 Connecting the Speaker 8 Software Installation... 9 EMC Precautions

More information

INSTRUCTION MANUAL. IntelliSense Automatic Blood Pressure Monitor with Easy Wrap Cuff. Model HEM-773AC

INSTRUCTION MANUAL. IntelliSense Automatic Blood Pressure Monitor with Easy Wrap Cuff. Model HEM-773AC R INSTRUCTION MANUAL IntelliSense Automatic Blood Pressure Monitor with Easy Wrap Cuff Model HEM-773AC TABLE OF CONTENTS Introduction...3 Notes on Safety...4 Know Your Unit...5 Quick Reference Guide...6

More information

#0086.

#0086. INSTALLATION MANUAL Contents Getting to Know Your AVANT A2D+... 3 Software Installation... 5 Driver Installation Windows 7... 8 Loading Calibration Files... 11 EMC Precautions... 12 Safety... 15 Limited

More information

Control Panel CP600 CP651, CP651-WEB

Control Panel CP600 CP651, CP651-WEB DATA SHEET Control Panel CP600 CP651, CP651-WEB 1 Ordering Data Part No. Description Product Life Cycle Phase 1SAP551100R0001 CP651, control panel, TFT graphical display, single-touch screen, 10.4, Active

More information

Instructions for use. 3year. Upper arm BASIS CONTROL. The number 1 blood pressure monitor in German pharmacies* Also suitable for:

Instructions for use. 3year. Upper arm BASIS CONTROL. The number 1 blood pressure monitor in German pharmacies* Also suitable for: Instructions for use Upper arm BASIS CONTROL The number 1 blood pressure monitor in German pharmacies* Arrhythmia detection Clinically validated 3year WARRANTY Also suitable for: Diabetics Kidney disease

More information

1 Re-Timer Instruction Manual

1 Re-Timer Instruction Manual Congratulations. You now own the world s most advanced light therapy device. Please read this manual carefully before using the device. Visit us at www.re-timer.com if you have any questions. 1 Re-Timer

More information

91370 SL2600 Compact Monitor

91370 SL2600 Compact Monitor Summary The Ultraview SL 2600 is a versatile compact monitoring system with a 12.1-inch resistive touchscreen display. Dual-battery slots allow this monitor to be used in transport, as well as at the bedside.

More information

Control Panel CP600 CP635, CP635-B, CP635-WEB

Control Panel CP600 CP635, CP635-B, CP635-WEB DATA SHEET Control Panel CP600 CP635, CP635-B, CP635-WEB 1 Ordering Data Part No. Description Product Life Cycle Phase 1SAP535100R0001 CP635, control panel, TFT graphical display, single-touch screen,

More information

Accurate home blood pressure measurements with the WatchBP Home. Instruction Manual

Accurate home blood pressure measurements with the WatchBP Home. Instruction Manual Accurate home blood pressure measurements with the WatchBP Home. Instruction Manual EN 3 Microlife WatchBP Home is the world s first digital blood pressure measurement device that strictly follows European

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200F, CPU 1214 FC, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY 125 KB General information

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200F, CPU 1215 FC, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24VDC; 10 DO 24V DC 0.5A; 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

SL2400 Compact Monitor

SL2400 Compact Monitor Summary The Ultraview SL 2400 is a compact monitoring system with a 10.4-inch resistive touchscreen display. Dual-battery slots allow this monitor to be used in transport, as well as at the bedside. The

More information

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version Ordering Data DATA SHEET TU520 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 214 400 R0001 1SAP 414 400 R0001 TU520-ETH, PROFINET I/O terminal unit, 24 VDC, spring

More information

TU531, TU532 Terminal Unit

TU531, TU532 Terminal Unit Ordering Data DATA SHEET TU531, TU532 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 217 200 R0001 1SAP 217 000 R0001 1SAP 417 000 R0001 TU531, terminal unit, 230 VAC,

More information

STANDARD OPERATING PROCEDURE TONOPORT V

STANDARD OPERATING PROCEDURE TONOPORT V Page 1 of 24 1. Scope This Standard Operating Procedure (SOP) applies to the staff and students using the Tonoport V in the Pharmacy Practice Resource Unit (PPRU) at the Pharmacy Department, University

More information

Control Panel CP600 CP635-FB, CP635-FW

Control Panel CP600 CP635-FB, CP635-FW DATA SHEET Control Panel CP600 CP635-FB, CP635-FW 1 Ordering Data Part No. Description Product Life Cycle Phase 1SAP535110R6001 CP635-FB, control panel, TFT graphical display, single-touch projected Active

More information

TF501, TF521 Terminal Bases

TF501, TF521 Terminal Bases Ordering Data DATA SHEET TF501, TF521 Terminal Bases 1 Ordering Data Part No. Scope of delivery Product life cycle status 1SAP 117 000 R0271 1SAP 317 000 R0271 1SAP 117 200 R0271 1SAP 317 200 R0271 TF501-CMS,

More information

SOMNOwatch plus. valid from 18 June 2013

SOMNOwatch plus. valid from 18 June 2013 SOMNOwatch plus valid from 18 June 2013 INDEX 1 SOMNOwatch TM plus Sets - Multi-channel 2 SOMNOwatch TM plus Sets - One-channel 3 SOMNOwatch TM plus Upgrade Sets - Multi-channel 4 SOMNOwatch TM plus Upgrade

More information

Version 1.0 December isappos 4 / isappos 5 Scanner Jacket

Version 1.0 December isappos 4 / isappos 5 Scanner Jacket User Manual Version 1.0 December 2016 isappos 4 / isappos 5 Scanner Jacket Copyright Copyright 2016 All Rights Reserved Manual Version 1.0 The information contained in this document is subject to change

More information

User's Manual. LEICKE Sharon ActivityTracker for smartphones with Bluetooth. Product number: WD67206

User's Manual. LEICKE Sharon ActivityTracker for smartphones with Bluetooth. Product number: WD67206 User's Manual LEICKE Sharon ActivityTracker for smartphones with Bluetooth Product number: WD67206 PACKAGE CONTENTS Before attempting to use this device, please check the packaging and make sure the following

More information

Quick Start Guide CJB1950ALAAB

Quick Start Guide CJB1950ALAAB Quick Start Guide 1 CJB1950ALAAB www.sar-tick.com This product meets applicable national SAR limits of 2.0W/kg. The specific maximum SAR values can be found in the section of this user guide. When carrying

More information

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Arm Cuff. Model HEM-711AC ESPAÑOL ENGLISH

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Arm Cuff. Model HEM-711AC ESPAÑOL ENGLISH INSTRUCTION MANUAL Automatic Blood Pressure Monitor with Arm Cuff Model HEM-711AC ENGLISH ESPAÑOL TABLE OF CONTENTS Before Using the Monitor Introduction..................................................3

More information

STANDARD OPERATING PROCEDURE TENSOVAL COMFORT

STANDARD OPERATING PROCEDURE TENSOVAL COMFORT Page 1 of 13 1. Scope This Standard Operating Procedure (SOP) applies to the staff and students using the Tensoval Comfort in the Pharmacy Practice Resource Unit (PPRU) at the Pharmacy Department, University

More information

1-Fiber Detachable DVI module, DVFX-100

1-Fiber Detachable DVI module, DVFX-100 Manual Contents www.opticis.com 1-Fiber Detachable DVI module, User s Manual Manual Contents 1-0 Welcome, Product Description 1-1 System Requirements for Setup 1-2 Installation 1-3 Self-EDID Programming

More information

TMT470L Temperature Transmitter

TMT470L Temperature Transmitter Technical information TMT470L Temperature Transmitter OEM components for compact thermometer/cable transmitter. 2/3 or 4-wire Pt100 can be connected. 4 to 20 ma transmitter, programmable via PC. Application

More information

TO65DS. 65" TOTEM Displays

TO65DS. 65 TOTEM Displays 65" TOTEM Displays PANEL MONITOR CONNECTIVITY H-Freq 67.5 khz Max. Pixel Freq. 74.25 MHz External Control V-Freq 60 Hz Cabinet T05 Backlight Type EDGE TYPE LED (DUAL STRING) Panel Type a-si TFT Tv Panel

More information

User manual. PhysioPortWin. PC-Software for Ambulatory Blood Pressure Monitor (ABPM)

User manual. PhysioPortWin. PC-Software for Ambulatory Blood Pressure Monitor (ABPM) User manual PC-Software for Ambulatory Blood Pressure Monitor (ABPM) PAR Medizintechnik GmbH & Co. KG Sachsendamm 6 10829 Berlin Germany 0482 Contents 1. GENERAL INFORMATION... 5 1.1 To this manual...

More information

Scout-S Station Controller

Scout-S Station Controller Scout-S Station Controller Substation Automation Scout-S Station Controller The Scout-S Station Controller is a SCADA enabled remote terminal unit (RTU) with a data concentrator, event reporter, and built-in

More information

Instructions for use. Upper arm BASIS. The blood pressure monitor for beginners to be used on your upper arm. Also suitable for: year WARRANTY

Instructions for use. Upper arm BASIS. The blood pressure monitor for beginners to be used on your upper arm. Also suitable for: year WARRANTY Instructions for use Upper arm BASIS The blood pressure monitor for beginners to be used on your upper arm Display Clinically validated Also suitable for: year WARRANTY Diabetics Kidney disease Pregnant

More information

MINER-S Station Controller

MINER-S Station Controller MINER-S Station Controller Substation Automation MINER-S Station Controller The MINER-S Station Controller is a SCADA enabled fixed point remote terminal unit (RTU) with a data concentrator, event reporter,

More information

Medimaging Integrated Solution Inc.

Medimaging Integrated Solution Inc. Medimaging Integrated Solution Inc. (MiiS) 1F, No. 7, R&D Rd II, Hsinchu Science Park, Hsinchu, TAIWAN 30076, R.O.C Issued date: Jan. 30, 2012 1 of 20 TABLE OF CONTENTS 1. Category 2. Symbols 3. Warnings

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, AC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA MEMORY: 50 KB General information

More information

testo 176 Data loggers

testo 176 Data loggers 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com testo 176 Data loggers Instruction manual 1 Contents 1 Contents 1 Contents...31

More information

TWINHEAD. Plug-In PC - PLUGTH series for Panasonic Professional Displays. Operating Instructions. PN1H (Model number PLUGTH series) English

TWINHEAD. Plug-In PC - PLUGTH series for Panasonic Professional Displays. Operating Instructions. PN1H (Model number PLUGTH series) English TWINHEAD English PN1H (Model number PLUGTH series) Plug-In PC - PLUGTH series for Panasonic Professional Displays Operating Instructions Before connecting, operating, or adjusting this product, please

More information

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with ComFit Cuff. Model BP755 ESPAÑOL ENGLISH BP755

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with ComFit Cuff. Model BP755 ESPAÑOL ENGLISH BP755 INSTRUCTION MANUAL Automatic Blood Pressure Monitor with ComFit Cuff Model BP755 BP755 ENGLISH ESPAÑOL CONTENTS Before Using the Monitor Before Using the Monitor Introduction...........................................3

More information

CardioMessenger Smart

CardioMessenger Smart CardioMessenger Smart Transmitter for BIOTRONIK Home Monitoring Technical Manual Doc. Id.: tbd_a Index 399229_ATechnical ManualCardioMessenger Smart 2 3 Table of Contents Introduction...................................................

More information

User manual Model: VIU-800 Brand:

User manual Model: VIU-800 Brand: User manual Model: VIU-800 Brand: - 1 - This manual s main purpose is to introduce the correct way of using the Voter Identification Unit / Electronic Voting Machine (hereinafter referred to as "the device").

More information

TO65SS 65 SINGLE SIDED TOTEM VERTICAL DIGITAL SIGNAGE DISPLAY

TO65SS 65 SINGLE SIDED TOTEM VERTICAL DIGITAL SIGNAGE DISPLAY PRODUCT SPECIFICATION Date:08.01.2017 TO65SS 65 SINGLE SIDED TOTEM VERTICAL DIGITAL SIGNAGE DISPLAY 1 SPECIFICATIONS TO65SS Panel H-Freq 67.5 khz Max. Pixel Freq. 74.25 MHz V-Freq 60 Hz Cabinet T05 Backlight

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1217C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT ONBOARD I/O: 10 DI 24V DC; 4 DI RS422/485; 6 DO 24V DC; 0,5A; 4 DO RS422/485; 2 AI 0-10V DC, 2 AQ 0-20MA; POWER SUPPLY: DC

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information

Safety Standards. Model Number:

Safety Standards. Model Number: 080AAS12 A Highlights & Features Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Low touch current (

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, AC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA

More information

Safety Standards. Model Number:

Safety Standards. Model Number: 060BAS12 A Highlights & Features Meet Efficiency Level VI Safety Approvals to IEC 60601-1 3rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Low touch current (

More information

Safety Standards. Model Number:

Safety Standards. Model Number: 060AAS19 B Highlights & Features Meet Efficiency Level VI Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Low touch current (

More information

ELECTRONIC PULSE MASSAGER ZX-581 USER MANUAL. Care for Your Loved Ones facebook.com/nursalonline

ELECTRONIC PULSE MASSAGER ZX-581 USER MANUAL. Care for Your Loved Ones   facebook.com/nursalonline ELECTRONIC PULSE MASSAGER ZX-581 USER MANUAL Care for Your Loved Ones www.nursal.co/warranty facebook.com/nursalonline ACTIVATE YOUR 12 MONTH WARRANTY & GET EXCLUSIVE GIFT Register within 2 weeks after

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 100 KB General information Firmware

More information

Operating Instructions for Orderman Sol & Sol+

Operating Instructions for Orderman Sol & Sol+ Operating Instructions for Orderman Sol & Sol+ 2010 by Orderman GmbH Bachstrasse 59, 5023 Salzburg Austria www.orderman.com Errors and misprints excepted. Duplication, reproduction or distribution, even

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 6 DI 24V DC; 4 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information Product

More information

MCG Technical Manual

MCG Technical Manual MCG Technical Manual MCG Technical Manual Premier Heart, LLC New York, 2017 Premier Heart, LLC Port Washington, New York, USA c 2017 Premier Heart, LLC. All rights reserved. Revision 2.2.1 Contents 1.

More information

TO65SS 65" TOTEM Displays

TO65SS 65 TOTEM Displays 65" TOTEM Displays Take the advantage of impulsive advertising with Finlux totems. Its robust design and flexibility make the totems perfect choice for variety of applications. PANEL H-Freq Max. Pixel

More information

Control Panel CP600-eCo CP604, CP604-B

Control Panel CP600-eCo CP604, CP604-B DATA SHEET Control Panel CP600-eCo CP604, CP604-B 1 Ordering Data Part No. Description Product Life Cycle Phase 1SAP504100R0001 CP604, control panel, TFT graphical display, single-touch screen, 4.3, Active

More information

testo 176 Datenlogger testo 176 Data loggers testo 176 Enregistreur de données Bedienungsanleitung Instruction manual Mode d'emploi

testo 176 Datenlogger testo 176 Data loggers testo 176 Enregistreur de données Bedienungsanleitung Instruction manual Mode d'emploi testo 176 Datenlogger Bedienungsanleitung testo 176 Data loggers Instruction manual testo 176 Enregistreur de données Mode d'emploi 1 Contents 1 Contents 1 Contents...31 2 Safety and the environment...32

More information

PDD-300 pulsed diode driver

PDD-300 pulsed diode driver rev 1.08 / 2019 02 13 PDD-300 pulsed diode driver User manual Warning! This equipment may be dangerous. Please read user manual before starting operations. Important note. Please measure output with adequate

More information

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, AC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA

More information

CM592 PROFIBUS Communication Module

CM592 PROFIBUS Communication Module Ordering Data DATA SHEET CM592 PROFIBUS Communication Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 173 200 R0001 1SAP 373 200 R0001 CM592-DP, communication module PROFIBUS

More information

Safety Standards. Model Number:

Safety Standards. Model Number: 150AAS12 F/B Highlights & Features Meet DOE Level VI and ErP Lot 7 Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Low touch current (

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

Safety Standards. Model Number:

Safety Standards. Model Number: 090AAS15 F/B Highlights & Features Meet Efficiency Level VI Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Low touch current (

More information

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with ComFit TM Cuff. Model HEM-711DLX ESPAÑOL ENGLISH

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with ComFit TM Cuff. Model HEM-711DLX ESPAÑOL ENGLISH INSTRUCTION MANUAL Automatic Blood Pressure Monitor with ComFit TM Cuff Model HEM-711DLX ENGLISH ESPAÑOL TABLE OF CONTENTS Before Using the Unit Introduction..............................................3

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/RLY, ONBOARD I/O: 8 DI 24V DC; 6 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Product

More information

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Engineering

More information

MD300 C5 Pediatric Oximeter

MD300 C5 Pediatric Oximeter MD300 C5 Pediatric Oximeter Specially designed to fit a wide range of pediatric patients Displays pulse rate and oxygen saturation Powered by 2 AAA batteries One button on/off 12 month warranty About the

More information

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ``` 400AUS24 B Highlights & Features Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Low touch current (

More information

DATASHEET. Ultra Capacitor Charger, UCC-4

DATASHEET. Ultra Capacitor Charger, UCC-4 DATASHEET Ultra Capacitor Charger, UCC-4 Easy installation Monitoring and surveillance of operation Balancing to save energy 90-450 V DC 3.5A Output Modular Ultra Capacitor system Document no.: 4921260003

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information

FL MC 2000E (SM40) LC

FL MC 2000E (SM40) LC IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Datasheet SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 8 DI 24V DC; 6 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information Engineering

More information

MINER-S Station Controller. Substation Automation

MINER-S Station Controller. Substation Automation Substation Automation MINER-S Station Controller incorporates traditional RTU functions with new technology in a compact design MINER-S Station Controller combines the functions of a traditional RTU with

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS SCOPE OF DELIVERY 1 Transmitter incl. lithium battery (3V, CR2032) 1 Chest strap (consisting of a transmitter and elastic strap) Item no. RUNBT1, type: TD00290 The elastic strap

More information

CM597 Ethernet Communication Module

CM597 Ethernet Communication Module Ordering Data DATA SHEET CM597 Ethernet Communication Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 173 700 R0001 1SAP 373 700 R0001 CM597-ETH, communication module Ethernet

More information

Safety Standards. Model Number:

Safety Standards. Model Number: 060AAS15 B Highlights & Features Meet Efficiency Level VI Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Low touch current (

More information

General information Engineering with Programming package. Display with display

General information Engineering with Programming package. Display with display Datasheet SIPLUS S7-1200 CPU 1212C AC/DC/RLY -40... +70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7212-1BE31-0XB0. COMPACT CPU, AC/DC/RELAY, ONBOARD I/O: 8 DI 24V DC 6 DO RELAY 2A 2 AI 0-10V DC, POWER

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information

More information

English Français. Instruction Manual B. 7 series Blood Pressure Monitor Model BP761CANN

English Français. Instruction Manual B. 7 series Blood Pressure Monitor Model BP761CANN English Français 7 series Blood Pressure Monitor Model BP761CANN Instruction Manual 2298824-1B English Product includes: El producto incluye: Battery Set jeu depiles Monitor Tensiomètre ComFit Cuff Brassard

More information

Instruction for use V

Instruction for use V Sierningstrasse 14 A-4521 Schiedlberg Austria Tel.: (43)-7251-22240-0 Fax: (43)-7251-22240-39 office@gtec.at, http://www.gtec.at Instruction for use Copyright 2011 g.tec medical engineering GmbH printed

More information

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes Datasheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY:

More information

English. Instruction Manual A. 7 series Blood Pressure Monitor Model BP761CAN. Français

English. Instruction Manual A. 7 series Blood Pressure Monitor Model BP761CAN. Français English Français 7 series Blood Pressure Monitor Model BP761CAN Instruction Manual 2298824-1A i English Product includes: Le produit inclut : Battery Set jeu depiles Monitor Tensiomètre ComFit Cuff Brassard

More information

Safety Standards. Model Number: Unit Weight:

Safety Standards. Model Number: Unit Weight: MEA-250A24C Highlights & Features Meet Efficiency Level VI Safety Approvals to IEC 60601-1 3.1 Ed. & IEC 60950-1 Compliant with IEC 60601-1-2 3 th and 4 th Ed. Requirements IP22 ingress protection rating

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Engineering

More information

Activity meter. Operating Instructions. AM 1400 adevital Activity. with Bluetooth and data management in linked app

Activity meter. Operating Instructions. AM 1400 adevital Activity. with Bluetooth and data management in linked app Activity meter with Bluetooth and data management in linked app Operating Instructions AM 1400 adevital Activity Subject to technical changes as a result of product improvements. Operating Manual_AM1400_EN_131214_REV001

More information

RT4F-110V/25A RECTIFIER

RT4F-110V/25A RECTIFIER The RT4F-110V/25A is a hot-pluggable switched mode rectifier (SMR) module designed to provide up to 25A of output current into a 110V nominal system. Examples of such systems are 60 cells lead acid (136V

More information

Miccus Stealth Mini. Water Resistant Sport Headphones Featuring Bluetooth 5 Wireless Technology. Model No.: MSMSH-50

Miccus Stealth Mini. Water Resistant Sport Headphones Featuring Bluetooth 5 Wireless Technology. Model No.: MSMSH-50 Miccus Stealth Mini Water Resistant Sport Headphones Featuring Bluetooth 5 Wireless Technology Model No.: MSMSH-50 Contents: Introduction & Overview................................... 2 Specifications

More information

RT4F-48V/50A-WAC RECTIFIER

RT4F-48V/50A-WAC RECTIFIER The RT4F-48V/50A-WAC is a switched mode rectifier (SMR) module designed to provide up to 58A of output current into a 48V nominal system, over a wide range of AC input voltage. This rectifier has been

More information

Quick Start Guide. For Android Tablet TR10RS1

Quick Start Guide. For Android Tablet TR10RS1 Quick Start Guide For Android Tablet TR10RS1 Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet *** SPARE PART*** SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General

More information

1 General Classification Definition of the H&B Application Classes Assignment of the H&B Application Classes to Devices...

1 General Classification Definition of the H&B Application Classes Assignment of the H&B Application Classes to Devices... Data Sheet 10/72-0.11EN Maestro UX Standard Data Contents: 1 General............................................................. 2 2 Classification.........................................................

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, AC/DC/RLY, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA MEMORY: 75 KB Display with

More information