RM-BC. DIN Rail Mount BCD to SSI Converter. Quality System
|
|
- Bryan Carr
- 5 years ago
- Views:
Transcription
1 RMBC DIN Rail Mount BCD to SSI Converter Quality System
2 Introduction This manual addendum contains information for the installation of the RMBC BCD to SSI (synchronous serial interface). The RMBC converter is designed to be used with model PMSSI, RMSSI or LDSSI display units. BCD, strobe and address input signal may be of the voltage free type s up to VDC. See "Electrical installation" chapter for requirements for various input voltage levels. The power supply is V or to VDC. The RMBC is a DIN rail mounting module and clips easily onto standard rails 35mm rails (EN500). Plug in electrical connections simplify installation and removal for service. The plug in terminals accept wires of up to.5mm INPUTS INPUTS 96 9 Model RMBC INPUTS The BCD data address and strobe correspond to display digits as shown below. i.e. digit is the right most display digit which is the least significant digit. Digit Digit Digit 6 Digit 5 Digit Digit 3 Digit Digit Page of 0 RMBCMAN.0
3 Mechanical installation The dimensions of the RMBC are shown in the diagram below. The RMBC is designed for DIN rail, horizontal mounting. The instrument snaps onto 35mm DIN standard rails (EN500). To install the unit simply clip onto the rail shown below. To remove lever the lower arm downwards as illustrated below DIMENSIONS mm INPUTS INPUTS 96 INPUTS 35mm 0mm Max. component height 35mm CLIPPING THE INSTRUMENT ONTO THE DIN RAIL AND REMOVAL FROM THE DIN RAIL To remove from DIN rail place broad bladed screwdriver under the clip lower arm and lever the arm downwards to pull the clip away from the DIN rail. Note that two clips are used on this mounting. Page 3 of 0 RMBCMAN.0
4 3 Electrical Installation The RM Rail Mount Process Module is designed for continuous operation and no power switch is fitted to the unit. It is recommended that an external switch and fuse be provided to allow the unit to be removed for servicing. The terminal blocks allow for wires of up to.5mm to be fitted. 3. bit parallel input connections Display unit settings Set disp = Addr, SEt OPER = bc RP, 5 & s RP RP RP, & input s RP LK RP LK LK, & INPUTS INPUTS 96 INPUTS Digit Digit Input circuit BCD bit input parallel connection LK Digit Digit BCD BCD RP RP Link to centre for Link to centre for voltage Page of 0 RMBCMAN.0
5 3. bit strobed input connections Display unit settings Set disp = Strb, SEt OPER = bc RP, 5 & s RP, & input s RP RP LK RP LK RP LK, & INPUTS INPUTS 96 INPUTS digit digit 3 digit digit BCD data Input circuit BCD bit input strobed connection LK BCD data strobe BCD digit digit 3 3 digit digit 0 9 RP RP Link to centre for Link to centre for voltage Page 5 of 0 RMBCMAN.0
6 3.3 bit addressed input connections Display unit settings Set disp = Addr, SEt OPER = bc RP, 5 & s RP, & input s RP RP LK RP LK RP LK, & INPUTS INPUTS 96 INPUTS Address Address Address Address BCD data Input circuit BCD bit input addressed connection LK address & strobe input Address BCD data input Address 3 Address Address 0 9 RP RP BCD Address input Digit addressed Link to centre for Link to centre for voltage Status Inactive Inactive Inactive Inactive Inactive Active Inactive Active Inactive Inactive Active Active Active Inactive Inactive Active Inactive Active Active Active Inactive Active Active Active Page 6 of 0 RMBCMAN.0
7 3. bit parallel input connections Display unit settings Set disp = PARL, SEt OPER = bc RP, 5 & s RP RP RP, & input s RP LK RP LK LK, & INPUTS INPUTS 96 INPUTS Digit 6 Digit 5 Digit Digit 3 Digit Digit Input circuit BCD bit input parallel connection LK Digit 6 Digit 5 BCD RP Link to centre for Link to centre for voltage LK Digit Digit RP Link to centre for Link to centre for voltage Digit Digit RP RP Page of 0 Link to centre for Link to centre for voltage RMBCMAN.0
8 3.5 bit strobed input connections Display unit settings Set disp = Strb, SEt OPER = bc RP, 5 & s RP, & input s RP RP LK RP LK RP LK, & INPUTS INPUTS 96 INPUTS digit digit digit 6 digit 5 digit digit 3 digit digit BCD data Input circuit BCD bit input strobed connection LK BCD data strobe digit 6 digit 5 digit 6 digit 5 3 digit digit 3 digit 0 digit 9 Not used BCD RP RP Page of 0 Link to centre for Link to centre for voltage RMBCMAN.0 Link to centre for Link to centre for voltage
9 3.6 bit addressed input connections Display unit settings Set disp = Addr, SEt OPER = bc RP, 5 & s RP, & input s RP RP LK RP LK RP LK, & INPUTS INPUTS 96 INPUTS Address Address Address Address BCD data Input circuit BCD bit input addressed connection LK input Address BCD data strobe input address input BCD Not used input Address Address 6 Address 5 3 RP RP Link to centre for Link to centre for voltage RP RP Address input Digit addressed Status Inactive Inactive Inactive Inactive Inactive Active Inactive Active Inactive Inactive Active Active Active Inactive Inactive Active Inactive Active Active Active Inactive Active Active Active Link to centre for Link to centre for voltage Page 9 of 0 RMBCMAN.0
10 3. Output connections The output from this unit is designed to be connected to a model PMSSI, LDSSI or RMSSI display/controller. See the appropriate model manual for electrical input and setup details. V or VDC V or VDC Clock B Clock A Data B Data A Power supply (non isolated) Use twisted pair overall screened cable Clock B Clock A Data B Data A Model PMSSI, RMSSI or LDSSI 3. Power supplies Power supplies required are V or to VDC. Supplies are non isolated (common ground or ve). DC current consumption is less than 30mA. 3.9 Link settings Links LK, LK and are used to select (to at 5VDC) or (to ) for the input lines. Place the link supplied between the centre connector and if the input signals are s from a switch, relay etc. or select if voltage signals are used. 3.0 s s RP, & are fitted for use as current limiting s on all the signal input lines. The value of the chosen depends on the level of the input voltage as sown in the table below. Input type or voltage networks RP, RP & 00Ω 5 volt input 00Ω volt input KΩ volt input KΩ volt input KΩ 3. Timing for strobe and address operation. As shown below the strobe line must become active no later than 0uS from the data and address lines becoming active. The strobe must be held active up to at least 0uS before the data and address lines become inactive. When the strobe is active the input is transparent i.e. if the data changes whilst the strobe is active then the change in the data input will be passed to the output. Date will be held whilst the strobe is inactive. The strobe must be active for at least 5uS. If more than one strobe is active then more than one digit will change. In addressed operation modes the strobe input is still needed before new data can be accepted. If necessary the strobe can be tied to a permanently active state. Data & address lines (example shown as active low) lines (example shown as active low) Setup time 0uS max. time 5uS Min. Hold time 0uS max. Page 0 of 0 RMBCMAN.0
SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER
SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting
More informationDigital Frequency Divider INSTRUCTION MANUAL CONTENTS. 1. Working Principle Installation Setting Up Technical Data 4.
Digital Frequency Divider INSTRUCTION MANUAL CONTENTS 1. Working Principle 2 2. Installation 2 3. Setting Up 3 4. Technical Data 4 Code: 189/1a 1 WORKING PRINCIPLE The DFD has been designed to generate
More informationAMALGAMATED INSTRUMENT CO PTY LTD ACN: LD-BC Binary/BCD/Gray Code Large Digit Display Operation and Instruction Manual
LD-BC Binary/BCD/Gray Code Large Digit Display Operation and Instruction Manual AMALGAMATED INSTRUMENT CO PTY LTD ACN: 00 589 9 Unit 5, 8 Leighton Place Hornsby NSW 077 AUSTRALIA Telephone: +6 976 Facsimile:
More informationSDM-8I8O. Expansion Module 8 digital inputs, 8 digital outputs. Manufactured for
Version 1.2 20.01.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationUsers Manual. TABLE OF CONTENTS 1 WORKING PRINCIPLE Operating limits Applications... 2
instrumentación para fluidos Digital frequency divider DFD-2 E Users Manual TABLE OF CONTENTS 1 WORKING PRINCIPLE... 2 1.1 Operating limits... 2 1.2 Applications... 2 2 INSTALLATION... 2 2.1 Mains connection...
More informationProcess displays For current and voltage
Features Voltage input TRMS-AC/DC up to 600 V Current input AC/DC 1 A, 5 A and shunt (precision resistor) 60 or 100 mv With 2 or 4 limits Display range can be linearised Min, Max, Hold functions 4 20 ma
More informationSDM-6RO. Expansion Module 6 relay outputs. Manufactured for
Version 1.0 5.02.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationRS485 MODBUS Module 8I8O
Expansion Module 8 digital inputs, 8 digital outputs Version 2.2 12/01/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the
More informationSDM-8AO. Expansion Module 8 analog outputs. Manufactured for
Version 1.0 16.05.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationTypical Input current at 1.15A 0.65A 60 Watt 24VDC / 2.5A. 1.84A 1.0A 120 Watt 24VDC / 5.0A
SmartPower TM The Autotech SmartPower is a DC switching power supply with 24V output Voltage. This user friendly power supply has two 7-segment LED displays for voltage and current monitoring. This DC
More information9000C INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING... 3 CONNECTION 3 INSTALLATION.. 4 ORDERING CODE 4 TROUBLE SHOOTING 4
Doc.Ref.No.:m92E/om/101 INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING... 3 CONNECTION 3 INSTALLATION.. 4 ORDERING CODE 4 TROUBLE SHOOTING 4 ISOLATED CONVERTER 9000C SERIES 9000C Series
More informationINSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3
INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page
More information170 ADI VDC - 16 Pt. Discrete Input Module Base
24 VDC - 16 Pt. Discrete Input Module Base 11 At a Glance Purpose This chapter describes the 170 ADI 340 00 TSX Momentum I/O base. In This Chapter This chapter contains the following sections: For This
More informationADDJOG User Guide 7/30/10. Overview
ADDJOG User Guide 7/30/10 Overview The ADDJOG is a PLC expansion board used to add digital inputs and outputs to a compatible host PLC. The ADDJOG has 64 open collector outputs and 64 non-isolated inputs.
More informationicex-cmtm General specs and Installation guide
icex-cmtm General specs and Installation guide 1. General view 2. Specifications 2.1. Common specs: Ethernet 1 x 10/100Base/T, RJ45 connector with traffic and link LED Serial Interface 1 x RS232/485 USB
More informationRS485 MODBUS Module 16I-M
Version 2.0 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationXT-9100 Technical Bulletin
System 9100 Technical Manual 636.4 Technical Bulletins Section Technical Bulletin Issue Date 0896 XT-9100 Technical Bulletin XT-9100 Extension Module/XP-910x Expansion Modules Page 3 Introduction 3 SX
More informationExpansion Module HZS 541-1S
Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs
More informationExpert I/O 1000 Hardware User Manual
Revision 4 January 6, 2010 2008-2010 Dajac Inc. All Rights Reserved. www.dajac.com sales@dajac.com Contents EXPERT I/O 1000...2 PIN CONFIGURATION...2 USB...3 DC IN...4 +B1/+B...4 +5V Output...4 +24V Input...4
More informationRSTI-EP Slice I/O. PROFINET Scanner EPXPNS001. GFK-2965C November 2017
November 2017 Ethernet Ports PWR, SF, BF, MT, LINK 1, ACT 1, LINK 2, and ACT 2 LEDs Door for Micro USB Port PROFINET Scanner Power Supply LED RSTI-EP Slice I/O PROFINET Scanner The PROFINET Scanner is
More informationDRC & MVP Series. Power Amplifiers MVP DRC Friendship Drive, Magnolia, TX Tel.: Fax:
DRC & Series DRC 4 Friendship Drive, Magnolia, TX 7755 Tel.: 8-59-7768 Fax: 8-59-749 www.hyvair.com DRC GENERAL FEATURES STANDARD FEATURES Easily configured using software or hand held interface LED indication
More informationRS485 MODBUS Module 6RO
Version 2.0 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationInstallation Manual CCL 20 D PTZ camera controller unit DIN-rail mounting
Installation Manual PTZ camera controller unit DIN-rail mounting CIB-tech I n t r o d u c t i o n The is a PTZ (Pan Tilt Zoom) video camera control unit, part of the CIB-tech automation system. The can
More informationBENCHMARK MEDIA SYSTEMS, INC.
BENCHMARK MEDIA SYSTEMS, INC. RLY-106 Instruction Manual 1.0 Introduction...1 2.0 Input and Output Connections...1 2.1 Connection Alternatives...2 3.0 Relay Ratings...2 4.0 Applications...4 4.1 Audio Signal
More information02/11/2015
24 x 48 Hour CTR24 non-backlit model Part number 87622162 Display : 8-digit LCD, height 8 mm Built-in module for voltage inputs 10 260 VAC/DC () 4 timing ranges : 99,999.99 hrs - 99,999.59 hrs - 999,999.9
More informationRemote I/O Product Specification
Table of Contents 1. Product Overview... 1 1.1 Product List:... 1 1.1.1 Coupler List:... 1 1.1.2 Digital I/O List:... 1 2. Fieldbus Coupler... 2 2.1 CANopen Specifications... 2 2.2 Ethernet TCP/IP Specifications...
More informationNon-communicating room controllers
3 882 DESIGO RXA Non-communicating room controllers RXA29.1 For fan-coil systems The RXA29.1 room controller are used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil systems,
More informationINSTALLATION INSTRUCTIONS
www.altroniccontrols.com INSTALLATION INSTRUCTIONS EXACTA 21 MONITORING AND CONTROL SYSTEM CAUTION: The EXACTA 21 CONTROL SYSTEM is CSA CERTIFIED FOR use in Class I, GROUPS C & D, Division 2 hazardous
More informationOverview. The DIN-RS232 has three primary functions: Isolated parallel RS-232 interface Fused power distribution Animatics peripheral expansion bus
user s guide DIN - RS232 user s manual 2 Overview The DIN-RS232 is a DIN rail mount breakout for SmartMotor RS-232 communications. It allows a single master to communicate with up to eight SmartMotors
More informationRemote I/O Product Specification
Table of Contents 1. Product Overview... 1 1.1 Product List:... 1 1.1.1 Coupler List:... 1 1.1.2 Digital I/O List:... 1 2. Fieldbus Coupler... 2 2.1 CANopen Specifications... 2 2.2 Ethernet TCP/IP Specifications...
More informationThe DVT Ethernet IO Module (CON-IOE)
The DVT Ethernet IO Module (CON-IOE) Revision 4 (11/11/04) DVT Corporation DVT Corporation Installation of DVT Ethernet IO Module (CON-IOE) Hardware Mechanical Installation: The CON-IOE is designed to
More informationUSBCNC USB Disk Key reader for CNC Controls Machine Mount instructions
USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions 2008-2015 Calmotion LLC, All rights reserved Calmotion LLC 21720 Marilla St. Chatsworth, CA 91311 www.calmotion.com Introduction This
More informationI2C-IN830M, I2C-IN830MA 8-Input Optocouplers I2C-bus, DIN rail supports
I2C-IN83M, I2C-IN83MA 8-Input Optocouplers I2C-bus, DIN rail supports Features PCF8574 and PCF8574A I2C chips upport khz I2C bus frequency On-board I2C bus pull-up resistors Address by 3 jumpers for use
More informationDIO-0808RN-USB. N Series for USB Isolated Digital I/O Unit(8ch Relay Output, 8ch DI) DIO-0808RN-USB 1. Ver.1.02
N Series for USB Isolated Digital I/O Unit(8ch Relay Output, 8ch DI) DIO-0808RN-USB *The above photograph is DIO-1616HN-USB. * Specifications, color and design of the products are subject to change without
More informationPepperl+Fuchs Fieldbus Power Hub for Redundant Fieldbus Power
Pepperl+Fuchs Fieldbus Power Hub for Redundant Fieldbus Power The Fieldbus Power Hub connects to one or two +24 VDC input power supplies and provides redundant fieldbus power to up to four fieldbus segments.
More informationRS 485 Mini Modbus 1AO
RS 485 Mini Modbus 1AO Version 1.0 14/08/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained
More informationDigital Modules AS-i in IP20, 22,5 mm
Digital Modules AS-i in 22,5 mm Cost efficient solution in IP20 (Figure similar) Figure Type Housing s digital digital voltage (sensor supply) (1) Output voltage (actuator supply) (2) AS-i connection (3)
More informationMINI MCR-SL-UI-REL(-SP)
Configurable Threshold Value Switch Data Sheet 11/2004 Method of Operation The configurable 3-way threshold value switch MINI MCR-SL-UI-REL(-SP) is used to control and monitor analog standard signals.
More informationSignal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information
Signal conditioning instruments for level switches Conductive VEGATOR C VEGATOR VEGATOR Product Information Content Content Product description..........................................................................
More informationRSTI-EP Slice I/O. EtherCAT Network Adapter Module EPXETC001. GFK-2967B Septembery 2016
Septembery 2016 RSTI-EP Slice I/O EtherCAT Network Adapter Module PWR, BF, MT, L/A IN, L/A OUT, RUN, and ERROR LEDs Ethernet Ports Door for Micro USB Port EtherCAT Network Adapter Power Supply LED The
More informationLVX Control Unit. Features:
Date 2013-02-28 Control Unit Features: Most parameters can be defined as required for your interfaces. You decide which information is output and how. Fast cycle times, just a few µs/beam. Maximum beam-count
More informationFaults on the system Proximity switch connection technology:
Speed monitor for connection to a base unit from the PNOZmulti modular safety system Approvals Unit features Monitoring of 2 independent axes Connection of 2 incremental encoders or 4 proximity switches
More informationTechnical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL
Technical documentation LIGHT CONTROL PANEL For use on seagoing vessels Change status Version Date Author Checked Remark 0.1 07.08.2008 STO HN 1. Edition Page 1 of 26 Table of contents 1. Application and
More informationF101, F102, F104. Relcom Installation Instructions. Fieldbus Power Supply F101-PS
F101, F102, F104 Fieldbus Power Supply F101-PS Installation Instructions Relcom www.mtl-fieldbus.com CONTENTS PAGE 1 OVERVIEW 2 2 DESCRIPTION 2 3 COMPONENTS AND ACCESSORIES 2 4 MECHANICAL 3 4.1 Mounting
More informationRS485 MODBUS Module 8AO
Version 1.3 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationUSBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version
USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version 2015 Calmotion LLC, All rights reserved Calmotion LLC 21720 Marilla Street Chatsworth, CA 91311
More informationBackplane. Allen-Bradley. System integration. Backplane
Backplane System integration Allen-Bradley Backplane Backplanes designed for minimum overall life cycle costs Simple, reliable and professional design Using standard cost-optimised DIN-rail devices Flexible
More informationOMNITERM LPI & LPD Loop Powered Isolators DATASHEET. Model C2063B LPI (single) & C2462A LPD (dual) 4-20mA Loop Powered Isolators.
Model C0B (single) & CA LPD (dual) 0mA Loop Powered Isolators Features Isolate any instrument current loop to 0ac Powered by the current loop no power supply required Lowest volt drop < Volts at 0 ma (,V
More informationABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS
Characteristics battery control module - 24..28.8 V DC - 24 V - 20 A - for regulated SMPS Main Range of product Product or component type Input voltage Output voltage Maximum output current Phaseo Battery
More informationMINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:
Extract from the online catalog MINI MCR-SL-UI-2I-NC Order No.: 2864176 4-way signal duplicator for electrical isolation and duplication of analog signals with screw connection, standard configuration
More informationZ-LINE Z201 Z-L LINE. AC Current. to DC ma/v isolator/converter CONVERTERS AND INTERFACES. Electric parameters conv verters
CONVERTERS AND INTERFACES AC Current Z-LINE Z201 to DC ma/v isolator/converter Z-L LINE Electric parameters conv verters INPUT:N.1 channel current 0..5 Aac or 0..10 Aac OUTPUT:N.1 channel current 0..20,
More informationData Sheet for Joysticks
Finger Joystick Series 87 Dual redundant outputs IP67 sealed lever heights: 8mm and 60mm 5 lever colors Series 87 is offering paddle joysticks of high precision and quality - claims that are not only supported
More informationDisplay and Monitoing Units
Display and Monitoing Units DISPLAY AND MONITOrING UNITS 13 The universal display unit HDA 5500 provides the means of visualizing and further processing the signals from our sensors. The unit is designed
More informationOTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m
Characteristics I/O distributed module OTB - Ethernet TCP/IP - 0..100 m Main Range of product Product or component type Integrated connection type Mar 31, 2018 Modicon OTB I/O distributed module Discrete
More information170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0
170 ADM 850 10 10 to 60 VDC Module Base / 170 ADO 830 30 6 Pt. Relay Out Module Base Version 1.0 31005197 00 Safety Information NOTICE Read these instructions carefully, and look at the equipment to become
More informationRS485 MODBUS Module 8I8RO
Expansion Module 8 digital inputs, 8 relay outputs Version 1.0 3.12.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device.
More informationRM4-2NO & RM8-2NO 180x77x65 (RM8 size) RM8-1C. RM8-2C & RM16-2C 202.5x77x68 (RM8 size) 8 or changeover. Yes. Yes.
Introduction Products offer a range of relay modules designed to provide Programmable controllers, PLC's and Microprocessor systems a power switching capability to their standard solid state outputs. The
More informationSignal Adapter. Signal Output. Power Input. Modell-Zug Elektronix Signal Adapter U.S.A. Momentary. Auxillary. Switch. Outputs
Adapter 1. Introduction Thank you for purchasing this product. The Adapter was specially designed to provide universal operation of the new generation of Märklin color light signals 74371, 74380, and 74391.
More informationEM2020 Selectable AC transducer A (UK)
Installation and start up instructions EM2020 Selectable AC transducer 4189300016A (UK) Watt or var transducer Supply and measuring voltage up to 690V Configuration via PC-interface possible FAGET 35 mm
More informationABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS
Characteristics battery control module - 24..28.8 V DC - 24 V - 40 A - for regulated SMPS Main Range of product Product or component type Input voltage Output voltage Maximum output current Complementary
More information- NLS NAVIGATION LIGHT CONTROL
Technical documentation - NLS 3000 - NAVIGATION LIGHT CONTROL For use on seagoing vessels Change status Version Date Author Checked Remark 0.1 07.08.2008 STO HN 1. Edition 0.2 29.09.2010 STO TK Changes
More informationAutoranging True RMS Multimeter User Manual
Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.
More informationMCU-9201MT22 venetian blind controller
MCU-9201MT22 venetian blind controller It is strongly recommended to read and follow the instructions in this manual carefully, before you start installing or programming a system. Installation, configuration
More informationUSER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series
USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series TEMPSEN DEVICES Plot No : 2&3, Balaji Nagar, 4 th Street, Mettukuppam, Thoraipakkam, Chennai-600097 Tele fax : +91-44-24581758,Mobil
More informationNEW Series SSH Output to 75A, 510 Vac with Diagnostics High Industrial Performance (HIPpak) Solid-State Relays
FEATURES/BENEFITS Zero-cross models with system diagnostics Very low zero-cross turn-on voltage Input and output protection and control LED standard IP20 protection by flaps on terminals With double removable
More informationNetBiter I/O Extender User Manual
User Manual Part no. 0920-9999-009 IntelliCom Innovation AB Pilefeltsgatan 73 SE-302 50 Halmstad SWEDEN Phone +46 35 17 29 90 Fax +46 35 17 29 09 email info@intellicom.se www www.intellicom.se Revision
More informationI/O Expansion Module Installation & Reference
Overview The In-Sight vision sensor supports up to ten discrete inputs and ten discrete outputs. Two inputs and two outputs are built-in to the In-Sight processor. The remaining eight inputs and outputs
More informationT M. IRDH375 Series. Digital Ground Fault Monitor / Ground Detector For Ungrounded (Floating) AC/DC Systems. Technical Bulletin NAE / 09.
T M 1 IRDH375 Series Digital Ground Fault Monitor / Ground Detector For Ungrounded (Floating) AC/DC Systems Technical Bulletin NAE101051 / 09.013 IRDH375 Series Digital ground fault monitor / ground detector
More informationOperation and Maintenance Manual
VM Series Operation and Maintenance Manual VM - Voltage Monitor VM-100-24 V VM-100-48 V VM-100-125 V VM-100-250 V EAGLE EYE POWER SOLUTIONS All Rights Reserved. 1 The Voltage Monitor series reads battery
More informationRSTI-EP Slice I/O. Digital Output Module
GFK-2959B December 2015 RSTI-EP Slice I/O Digital Output Modules EP-2214, EP-2614, EP-2634, EP-2218, EP-225F Relay Output Module Solid-state Relay Output Module EP-2814 Module Status LED Channel Status
More informationUNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN
1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,
More informationInstruction Manual. ICENI/TB-02 Terminal Block Module (Type 2) Pub_ Issue 1
Instruction Manual ICENI/TB-02 Terminal Block Module (Type 2) Pub_3652 - Issue 1 Regulateurs Europa Ltd 2014 The contents of this document are the exclusive Property of Regulateurs Europa Ltd They must
More informationDisplays Transducers. Displays and transducers
JJ Displays JJ Transducers Displays and transducers DS_Displays_and_transducers 06/2016 225 Displays and transducers Our electronic devices for flow and volume measurement are suitable for all SIKA flow
More informationInstallation and commissioning guide SmartLink PSD Power Supply Module (DC)
Installation and commissioning guide SmartLink PSD Power Supply Module (DC) Rev. 1 September 2012 Part No. 4417551 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15
More informationEasy Analog RNB130. Technical Information. Primary switched-mode power supply
Technical Information Easy Analog RNB130 Primary switched-mode power supply Your benefits Small housing, 35 mm (1.38") width High availability Wide range input - can be used world-wide Power reserve (Power
More informationTRIO-DIODE/12-24DC/2X10/1X20
Redundancy module INTERFACE Data sheet 104278_en_00 1 Description PHOENIX CONTACT 20100423 Features TRIO DIODE is the DINrail mountable redundancy module from the TRIO POWER product range. Using the redundancy
More informationMBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit
MBP68300 SERIES AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters Modular Construction AC-distribution 3pcs of MCBs Manual bypass switch BPU69000 Dual External static switch
More informationEXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.
EXPANSION PERIPHERAL CVM-R10 C (Code 7 70 217 ) INSTRUCTION MANUAL ( M 981 170 / 00 A ) (c) CIRCUTOR S.A. ------ CVM-R10 C Peripheral --------------- Pag. 1 CVM-R10C EXPANSION PERIPHERAL 1.- DESCRIPTION
More informationRSTI-EP Slice I/O Digital Input Modules EP-1214, EP-1218, EP-1318, EP-125F, EP-1804 Digital Input Module with Time Stamp EP-12F4
GFK-2975C August 2016 Module Status LED Channel Status LEDs Digital Input Connector Ground 24 V DC FE Digital Input Module RSTI-EP Slice I/O Digital Input Modules EP-1214, EP-1218, EP-1318, EP-125F, EP-1804
More informationVZBs. Power PCB Relay RT2 2 pole 8 A, DC and AC-coil. Features. Contact data
Features 2 C/O or 2 N/O contacts Sensitive coil 400 mw DC- or AC-coil 5 kv / 10 mm coil-contact Protection class II (VDE 0700) Height 15.7 mm Sockets with PCB-type or screw-type terminals Applications
More informationTable of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7
User's Manual: Series 330I Model 330I DC-Powered Three-Way Isolator Table of Contents Page Introduction... 2 Description....2 Specifications....3 Installation.. 5 Calibration.. 6 General Maintenance...7
More information170 ADO VDC - 32 Pt. Discrete Output Module Base
31001697 9/2010 170 ADO 350 00 24 VDC - 32 Pt. Discrete Output Module Base 27 Overview This chapter describes the 170 ADO 350 00 TSX Momentum I/O base. What's in this Chapter? This chapter contains the
More informationHEATIT Z-WATER. Regulator for water-based heating systems. Installation guide. Analog inputs - Firmware ver
HEATIT Z-WATER Installation guide 01.07.2017 Regulator for water-based heating systems Analog inputs - Firmware ver. 1.0 Ver 2017-A 2 yr Thermo-Floor AS, Østre Totenvei 24, NO-2816 Gjøvik, Norway, Phone:
More informationMODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)
Super-mini Terminal Block Signal Conditioners M5-UNIT CURRENT LOOP SUPPLY Functions & Features Powering a 0 ma DC current loop Applicable to smart transmitters Isolation between the input and output Fast
More informationFP-PS-4. Features. Installation
OPERATING INSTRUCTIONS FP-PS-4 FieldPoint Power Supply These operating instructions describe the installation, features, and characteristics of the FP-PS-4. Features The FP-PS-4 is a FieldPoint power supply
More informationDSP240-LPI Inverter Controller Card. Technical Brief
DSP240-LPI Inverter Controller Card Technical Brief September 2006 Manual Release 3.0 Card Revision 3.0 Copyright 2001-2006 Creative Power Technologies P.O. Box 714 MULGRAVE Victoria, 3170 Tel: +61-3-9543-8802
More information4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current
Quattro-Relais Quattro Relay 4 Quattro Relay 4A4 Standard type / With LED and protection diode on request Quattro-Relais Order Code Order Code Quattro Relay 4 A 4 4 V DC N Type of relay Quattro Relay 4
More informationMEASURING AND TESTING INSTRUMENTS
MEASURING AND TESTING INSTRUMENTS Whether measuring temperature, current or voltage testing the right measuring tool can facilitate the everyday work. If one wants to perform several measuring tasks at
More informationLANCNC FTP Data Server for CNC Controls Machine Mount instructions
LANCNC FTP Data Server for CNC Controls Machine Mount instructions 2008-2016 Calmotion LLC, All rights reserved Calmotion LLC 21720 Marilla Street Chatsworth, CA 91311 www.calmotion.com Introduction This
More informationTime Counters mini "h", DC Version
Type 633-DC Time Counters mini "h", DC Version Type 633.0 Type 633.7 Type 633.8 High shock resistance Miniature dimensions Electrical connections in standard grid Suitable for PCB mounting Machine-solderable
More informationWP-Line 351 MK ll Combi I/O. control systems. Optimized I/O Combi module. 2 serial COM-ports
Optimized I/O Combi module 2 serial COM-ports 16 digital outputs/26 digital inputs/4 high-speed counter inputs 4 analog outputs/8 analog inputs/8 PT100 inputs/2 thermistor inputs Compact design Improved
More informationFP-1600 FieldPoint Quick Start Guide
FP-1600 FieldPoint Quick Start Guide What You Need to Get Set Up 1 Network Module Mounting Hardware (DIN rail or panel mount accessory) Terminal Base(s) I/O Module(s) Install the Network Module DIN Rail
More informationMODULES FOR SAFETY AND MONITORING
MODULES FOR SAFETY AND MONITORING Woertz AG Hofackerstrasse 47, P.O. Box 948, CH-43 Muttenz, Switzerland Tel. ++4 6 / 466 33 33, Fax ++4 6 / 46 96 06 http://www.woertz.ch Woertz-USA 5 Discovery Drive,
More informationDigital SSI Converter DIGICON V2
Digital SSI Converter V2 Type: DK/SSS Version 2 Digitronic Auf der Langwies 1 D - 65510 Hünstetten-Wallbach Tel. +49 6126 9453-0 Fax -42 Internet: http://www.digitronic.com E-Mail: mail@digitronic.com
More informationOHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L
AC PROGRAMMABLE TRANSDUCERS MODBUS OR LONWORKS DESCRIPTION The DMT-1000 is a programmable transducer with an RS-485 bus interface (MODBUS ). It supervises several variables of a poly-phase electrical power
More informationRotary Measurement Technology Absolute Encoders, Singleturn
-20 to 85 C High rotational speed Temperature Shock/ vibration resistant Short-circuit proof Reverse polarity protection Rugged Highest shock resistance on the market: ( 200 g (2,500 m/s 2 )), 6 ms acc.
More informationIMC-21 Quick Installation Guide
IMC-21 Quick Installation Guide Moxa Industrial Media Converter Edition 5.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777
More informationManual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel
Manual# 1006495 Installation Manual 200E Series DCU 210E/208E Engine Panel RP 210E/220E Remote Panel Installation Manual for the Marine Pro 200E Series ~~~ DCU 210E/208E Diesel Engine Control Unit RP 210E/220E
More informationTwo-hand relay modules SRB 201ZH 44 Schmersal Industrial switching systems
SR 2ZH A 23 3 3 X S2 S A. K K2 PROTECT SR 2ZH Dimensions Two-hand module to DIN EN 574 (997) type III C Plug-in terminals 2 safety enabling outputs feedback output with NC function (floating contact) Electronic
More informationUser Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX
User Manual MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX CE MARKING This equipment complies with the requirements relating to electromagnetic compatibility, EN 55022 class A for ITE, the
More information