Weighing Electronics Stand-alone integrators
|
|
- Olivia Park
- 5 years ago
- Views:
Transcription
1 Overview pplication operates with any solids flowmeter with up to two strain gauge load cells or LVDT sensor. The SF500 processes sensor signals for accurate flow rate and totalized weight of bulk solids. It can take on lower level control functions traditionally handled by other devices, and it supports popular industrial communication buses. Its proven load cell balance function eliminates matching of load cells. The PID function may be used for rate control of pre-feeding devices and/or control of additives with two internal PID controllers. Operating in tandem with two or more solids flowmeters or weighfeeders, the SF500 may be used for ratio blending and controlling additives. Batching, load out, and alarm functions are also provided by the SF500. Dolphin Plus software may be used for programming the unit with a PC. is a full feature integrator for use with solids flowmeters. Benefits utomatic zero and electronic span calibration larms for rate or diagnostic error On-board Modbus, optional PROFIBUS DP, PROFINET, Modbus TCP/IP, EtherNet/IP, and DeviceNet On-line calibration and dual PID control with optional analog I/O card Multi-point linearizer for high turn down accuracy Up to 8 multi-spans for application of more than one flow condition and/or material Moisture meter input with optional analog I/O card for calculation of dry weight /8 Siemens WT
2 Technical specifications Mode of operation Power supply Measuring principle Typical application Input Flowmeter integrator Compatible with SITRNS solids flowmeters or equivalent 1 or load cell models Compatible with LVDT equipped solids flowmeters, with use of optional interface board (remotely mounted) Standard C version V C ± 10 %, 50/60 Hz, 55 V max. Fuse FU3 = G, MP, 50 V Slo Blo DC version V DC, 6 W max. Fuse FU = 3.75 resettable (not user replaceable) Load cell/lvdt uto zero m uxiliary Output m Load cell/lvdt conditioner card Remote totalizer 1 Remote totalizer Relay output Measuring accuracy Resolution ccuracy Rated operating conditions 0 45 mv DC per load cell or LVDT interface card Dry contact from external device See optional m I/O board 5 discrete inputs for external contacts, each programmable for either: display scrolling, totalizer 1 reset, zero, span, multi-span, print, batch reset, PID function, or on-line calibration Programmable 0/ m, for rate, optically isolated, 0.1 % of 0 m resolution, 750 load max. (see optional m I/O board) 10 V DC compensated excitation for strain gauge type, cells max., 150 m max. Contact closure ms duration Solid state relay contact 30 V DC, 100 m max. Max. contact on-resistance = 36 ohms Max. off-state leakage = 1 Contact closure ms duration Solid state relay contact rated 40 V C/DC, 100 m max. Max. contact on-resistance = 36 ohms Max. off-state leakage = 1 5 alarm/control relays, 1 SPST Form relay contact per relay, rated 5 at 50 V C, non-inductive or 30 V DC 0.0 % of full scale 0.1 % of full scale Controls and displays Display Programming Memory Communications pprovals Options Illuminated 5 x 7 dot matrix liquid crystal display with lines of 40 characters each Via local keypad and/or Dolphin Plus interface Program stored in non-volatile FLSH ROM, upgradeable via Dolphin Plus interface Parameters stored in battery backed RM, 3 V NED 5003LC or equivalent, 10 year life Two RS 3 ports One RS 485 port SmartLinx compatible CE, CS US/C, FM, RCM, EC, KCC Dolphin Plus: Windows based software interface. Refer to associated product documentation. SmartLinx modules: protocol specific modules for interface with popular industrial communications systems. Refer to associated product documentation. LVDT interface card: for interface with LVDT based solids flowmeters m I/O board - Inputs: programmable 0/4 0 m for PID control or online calibration, optically isolated, 0.1 % 0 m resolution, 00 input impedance - Outputs: programmable 0/4 0 m for PID control or rate output, optically isolated, 0.1 % of 0 m resolution, 750 load max - Output supply: isolated 4 V DC at 50 m, short circuit protected mbient conditions Location Indoor/outdoor mbient temperature C (-5 +1 F) Relative humidity/ingress protection Suitable for outdoor/ Type 4X/NEM 4X/IP65 Installation category II Pollution degree 4 Design Material (enclosure) Polycarbonate Dimensions 09Wx85Hx9Dmm (8.Wx11.Hx3.6Dinch) Weight.6 kg (5.7 lb) Siemens WT /9
3 Selection and ordering data 1) ) rticle No. Order code full feature, powerful integrator designed for use with solids flowmeters 7MH Click on the rticle No. for the online configuration in the PI Life Cycle Portal. Input voltage C voltage DC voltage 3 uxiliary input/output boards 1) None Board with analog inputs and analog outputs B Feature software Standard uxiliary memory None 0 Data communications ) SmartLinx Ready 0 SmartLinx PROFIBUS DP module SmartLinx DeviceNet module 3 SmartLinx PROFINET module 4 SmartLinx EtherNet/IP module 5 SmartLinx Modbus TCP/IP module 6 Enclosures Standard enclosure, no entry holes 1 Standard enclosure, 4 entries, for M0 glands Trade approval stickers No trade approval sticker Not legal for Canadian and EU trade sticker B pprovals CE, CSUS/C, FM, RCM Further designs Please add "-Z" to article no. and specify order code(s). Stainless steel tag (69 mm x 50 mm), Y15 Measuring-point number/identification (max 7 characters), specify in plain text. Stainless steel, sun/weather shield S x 305 x 03 mm (14 x1 x 8 inch) (finished unit is field mounted with enclosure) Manufacturer's test certificate: C11 ccording to EN LVDT conditioner card mounted and connected for G1 use with LVDT flowmeters Stainless steel enclosure, 304 (1.4301), [406 x 305 x 15 mm (16 x 1 x 6 inch), Type 4X, IP66; (finished unit is mounted inside enclosure)] With window 11 Without window 1 Painted mild steel, [406 x 305 x 15 mm (16 x 1 x 6 inch), Type 4, IP65; (finished unit is mounted inside enclosure)] With window 13 Without window 14 Painted mild steel, anti-vibration enclosure with 15 viewing window [406 x 305 x 03 mm (16 x 1 x 8 inch), Nema/Type 4, IP66; (finished unit is mounted inside enclosure)] Painted mild steel, heated enclosure with viewing 35 window for use down to -50 C (-58 F) (finished unit is mounted inside enclosure) 483 x 584 x 03 mm (19 x 3 x 8 inch) Instruction manuals rticle No. SF500, English 5E SF500, German 5E Note: the instruction manual should be ordered as a separate item on the order. ll literature is available to download for free, in a range of languages, at This device is shipped with the Siemens Level and Weighing manual DVD containing the complete instruction manual library. dditional instruction manuals SmartLinx PROFIBUS DP, English 7ML1998-1Q03 SmartLinx PROFIBUS DP, German 7ML1998-1Q33 SmartLinx DeviceNet, English 7ML1998-1BH0 Note: the appropriate SmartLinx instruction manual should be ordered as a separate line on the order. LVDT Conditioner Card Manual, English 7ML1998-5EF01 LVDT Conditioner Card Manual, German 7ML1998-5EF31 ll literature is available to download for free, in a range of languages, at This device is shipped with the Siemens Level and Weighing manual DVD containing the complete instruction manual library. 1) ) Required for PID control and online calibration. Required for industrial communications. /10 Siemens WT
4 Selection (continued) and ordering data Optional equipment uxiliary I/O card spare LVDT Conditioners in NEM 4 enclosure (to interface LVDT belt scale without internal pre-amplifier) Cables to connect BW500/SF500 keypad to motherboard SITRNS RD100 Remote displays - see RD100 on page /1 SITRNS RD00 Remote displays - see RD00 on page /3 SITRNS RD300 Remote displays - see RD300 on page /7 SITRNS RD500 web, datalogging, alarming, Ethernet, and modem support for instrumentation - see on page /31 Spare parts Display card Lid with overlay and keypad SF500 motherboard, C SF500, motherboard, DC Fuse,, 50 V, BW500, BW500/L, and SF500, spare Keypad spare for BW500, BW500/L, and SF500 LVDT card spare PROFINET IO module Modbus TCP/IP, EtherNet/IP module PROFIBUS DP module DeviceNet module rticle No. 7MH773-1BJ 7MH773-1J 7MH773-1CB 7ML MH773-1F 7MH773-1G 5E E MH773-1DG 7MH773-1CD 5E ML1830-1PM 7ML1830-1PN 7ML1830-1HR 7ML1830-1HT /11
5 Dimensional drawings 16 (0.6) 09 (8.) 17 (6.8) Lid screws (6 places) 9 (3.6) Non-metallic enclosure does not provide grounding between connections. Use grounding type bushings and jumpers. 67 (10.5) 85 (11.) Conduit entry Mounting hole (4 places) Lid Enclosure Customer supplied mounting screws, dimensions in mm (inch) Schematics Cable Load cell excitation Load cell inputs Speed sensor V+ 11 S+ 1 S- 13 V- 14 SHLD15 SIG 16 COM 17 CNST 18 +EXC 19 SHLD 0 Speed sensor signal level 1 M+ 1 LC+ LC- 3 LCB+ 4 LCB- 5 SHLD 6 LCC+ 7 LCC- 8 LCD+ 9 LCD- 10 SHLD M- 3 SHLD 4 UX1 5 UX 6 UX3 7 UX4 8 UX5 9 COM 30 - Z COM 3 RX 33 SHLD 34 B(+) 35 (-) 36 COM 37 SHLD 40 One load cell: - Non-sensing: Belden 8404, 4 wire shielded, 0 WG (0.5 mm ) or equivalent, 150 m (500 ft) max. - Sensing: Belden 960, 6 wire shielded, 0 WG (0.5 mm ) or equivalent, 300 m (1 000 ft) max. Two load cells: - Non-sensing: Belden 960, 6 wire shielded, 0 WG (0.5 mm ) or equivalent, 150 m (500 ft) max. - Sensing: Belden 8418, 8 wire shielded, 0 WG (0.5 mm ) or equivalent, 300 m (1 000 ft) max. uto zero: Belden 8760, 1 pair, twisted/shielded, 18 WG (0.75 mm ) or equivalent, 300 m (1 000 ft) max. Remote total: Belden 8760, 1 pair, twisted/shielded, 18 WG (0.75 mm ) or equivalent, 300 m (1 000 ft) max. RS 3 RS 485 TX 31 B(+) 38 (-) RLY RLY RLY RLY RLY5 50 SHLD 51 T1 + 5 T1-53 SHLD 54 T + 55 SHLD 57 T - 56 SHLD 57 L1 58 L/N DC version connections /1 Siemens WT
Weighing Electronics Stand-alone integrators
Siemens AG 017 Overview Benefits Automatic zero and electronic span calibration Alarms for rate, load, speed, or diagnostic error On-board Modbus, optional PROFIBUS DP, PROFINET, Modbus TCP/IP, EtherNet/IP,
More informationSiemens AG Criteria Milltronics BW100 Milltronics BW500 Milltronics SF500 Applications and compatibility
Weighing Electronics Stand-lone Integrators Siemens G 009 Introduction Overview Integrators process sensor signals into operating data for continuous in-line weighing. They can take over basic control
More informationWeighing Electronics
Siemens AG 011 Weighing Electronics / Stand-alone Integrators / Introduction /3 Milltronics BW100 /7 Milltronics BW500 /11 Milltronics SF500 /15 Accessories /15 Dolphin Plus Software /16 SITRANS RD100
More informationLevel Measurement Continuous level measurement Ultrasonic controllers
Overview is a versatile short to mediumrange ultrasonic single and multivessel level monitor/controller for virtually any application in a wide range of industries. Application can be used with various
More informationLevel Measurement Continuous level measurement - Ultrasonic controllers
Continuous level measurement Ultrasonic controllers Overview is a versatile short to mediumrange ultrasonic single and multivessel level monitor/controller for virtually any application in a wide range
More informationInstruction Manual April 2001 CCUMASS SF500
ACCUMASS SF500 Instruction Manual April 2001 CCUMASS SF500 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected
More informationInstruction Manual April milltronics SF500
Instruction Manual April 2007 milltronics SF500 Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment.
More informationContinuous level measurement Ultrasonic controllers
Siemens AG 0 Overview is a complete ultrasonic level controller for monitoring and control of water distribution and wastewater collection systems, with energy-saving algorithms. Benefits Monitoring and
More informationIntegrators. Milltronics BW500 and BW500/L. Operating Instructions 04/2014. Milltronics
Integrators Milltronics BW500 and BW500/L Operating Instructions 04/2014 Milltronics Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect
More informationSITRANS L Level instruments
Overview Technical specifications Mode of Operation Measuring principle Ultrasonic level measurement Measuring range 0.3 to 1 m (1 to 0 ft), transducer dependent Measuring points 1 or 2 Input Analog 0
More informationLevel Measurement. Continuous level measurement - Ultrasonic controllers. SITRANS LU01 and LU02. 5/156 Siemens FI Overview.
SITRANS LU and LU Siemens AG Overview Overview The SITRANS LU is an ultrasonic long-range level controller for liquids and solids in a single vessel up to 6 m ( ft). Handheld programmer shown is an accessory
More informationLevel instruments. Continuous level measurement - Ultrasonic controllers SITRANS LUC500. 5/146 Siemens FI
SITRANS LUC00 Siemens AG 009 Overview SITRANS LUC00 is a complete ultrasonic level controller for monitoring and control of water distribution and wastewater collection systems, with energy-saving algorithms.
More informationACCUMASS BW500. Instruction Manual PL-565 April Rev 1.0
ACCUMASS BW500 Instruction Manual PL-565 April 1999 33455650 Rev 1.0 Ultrasonic level Radar A t Milltronics, we endeavour to design equipment that is simple to use and reliable in its operation, with the
More informationInstruction Manual July milltronics BW 500
Instruction Manual July 2004 milltronics BW 500 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment.
More informationFlow Measurement SITRANS F US Clamp-on
Overview SITRNS FUS1010 is the most versatile clamp-on ultrasonic flow display transmitter available today. It can operate in either Wide- Beam Transit time or Reflexor (Doppler) mode, making it suitable
More informationACCUMASS BW500. Instruction Manual May 2002 ACCUMASS BW500
ACCUMASS BW500 Instruction Manual May 2002 ACCUMASS BW500 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected
More informationLevel Measurement. Continuous level measurement Ultrasonic controllers. SITRANS LUT400 series 5/337. Overview
Overview The Siemens controllers are compact, single point, long-range ultrasonic controllers for continuous level or volume measurement of liquids, slurries, and solids, and high accuracy monitoring of
More informationIntegrators. Title page without bleed in RGB. Milltronics BW500 and BW500/L. Operating Instructions
Title page without bleed in RGB Bufferzone Find any font sizes for the text fields in the Panel "Paragraph styles"! The image must not touch with the Bufferzone. Background coolgray 20%, without history
More informationLevel measurement. Continuous level measurement Ultrasonic controllers. SITRANS LUT400 series. 4/146 Siemens FI Overview
Level measurement SITRNS LUT00 series Siemens G 2013 Overview pplication The SITRNS LUT00 comes in three different models, depending on the application, level of performance and functionality required:
More informationLevel instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview
Overview The is a universal input, panel mount remote digital display for process instrumentation. Benefits Easy setup and programming via front panel buttons or remotely using RD software Display readable
More informationFlow Measurement SITRANS F US Clamp-on
Overview SITRNS FUG1010 clamp-on non-intrusive ultrasonic flow transmitter is ideal for natural and process gas applications, including checkmetering, allocation, production, storage and gas fired power
More informationSITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview
Overview The combination of sensor SONO 3300 sensor and FUS060 transmitter is ideal for applications within the general industry. Measurements are independent of liquid temperature, density, pressure and
More informationECHOMAX XPS-10 ULTRASONIC TRANSDUCER
Datasheet ECHOMX XPS-10 ULTRSONIC TRNSDUCER Supplied by.com Call us on + (0)118 916 920 Email info@27able.com Overview transducers use ultrasonic technology to measure level in a wide range of liquids
More informationContinuous level measurement Ultrasonic transducers
Siemens G 2013 Overview transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing effect reduces blanking distance
More informationContinuous level measurement Ultrasonic transducers
Siemens G 2012 Level measurement Overview EchoMax XPS/XCT transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing
More informationLevel Measurement. Continuous level measurement Ultrasonic controller. SITRANS LUT400 series 5/337. Overview
Overview The Siemens controllers are compact, single point, long-range ultrasonic controllers for continuous level measurement of liquids, slurries, and solids, and high accuracy monitoring of open channel
More informationLevel Measurement Continuous level measurement - Ultrasonic controllers
SITRANS LUT00 series Overview The SITRANS LUT00 series controllers are compact, single point, long-range ultrasonic controllers for continuous level or volume measurement of liquids, slurries, solids,
More informationLevel Measurement Continuous level measurement Ultrasonic controllers
Overview The Siemens controllers are compact, single point, long-range ultrasonic controllers for continuous level or volume measurement of liquids, slurries, and solids, and high accuracy monitoring of
More informationSITRANS F flowmeters SITRANS F US. SITRANS FUS1010 Standard clamp-on. 4/270 Siemens FI Overview
SITRNS F flowmeters Siemens G 2009 Overview SITRNS FUS1010 is the most versatile clamp-on ultrasonic flow display computer available today. It can operate in either Wide- Beam Transit-Time or Reflexor
More informationContinuous level measurement Radar transmitters
Overview Configuration Mounting on a nozzle Min. clearance: 10 (0.4) Installation min. 1 000 (39) is a 2-wire 2 GHz pulse radar level transmitter for continuous monitoring of solids in storage vessels
More informationLevel Measurement Continuous level measurement - Ultrasonic controllers
SITRANS LUT00 series Overview The SITRANS LUT00 series controllers are compact, single point, long-range ultrasonic controllers for continuous level or volume measurement of liquids, slurries, solids,
More informationFlow Measurement. SITRANS F US Clamp-on. SITRANS FUG1010 (Gas) 4/336 Siemens FI Overview
Siemens G 2010 Overview pplication SITRNS FUG1010 is ideal for most natural and process gas industry applications, including: Checkmetering llocation Flow survey verification Lost and unaccounted for (LUF)
More informationContinuous level measurement Ultrasonic transducers
Siemens G 2012 Level Measurement Overview Echomax XPS/XCT transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing
More informationSITRANS F flowmeters SITRANS F US. SITRANS FUH1010 Oil clamp-on. 4/294 Siemens FI
SITRNS F flowmeters Siemens G 2009 Overview Standard volume (net) or mass flowmeters ( standard volume / mass ) Exceptional repeatability is maintained, independent of changes in temperature, density or
More informationSiemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.
Overview Configuration Mounting on a nozzle Min. clearance: 10 (0.4) Installation min. 1 000 (39) is a 2-wire 2 GHz pulse radar level transmitter for continuous monitoring of solids in storage vessels
More informationSiemens AG Continuous level measurement Ultrasonic controllers
Overview The Siemens controllers are compact, single point, long-range ultrasonic controllers for continuous level or volume measurement of liquids, slurries, and solids, and high accuracy monitoring of
More informationCOMPU - M INTEGRATOR. Instruction Manual PL-453. July PRR 1.0
COMPU - M INTEGRATOR Instruction Manual PL-453 July 1995 33454530 PRR 1.0 TABLE OF CONTENTS Section Page GENERAL INFORMATION SPECIFICATIONS The Compu-M 1 1 Compu-M 2 1 Current Output Isolator 2 2 Cabling
More informationLevel instruments. Continuous level measurement - Radar transmitters SITRANS LR560. 5/2 Siemens FI Overview.
Overview onfiguration 2-wire, 78 GHz FMW radar level transmitter for continuous monitoring of solids in silos to a range of 100 m (329 ft). enefits rugged stainless steel design for industrial applications
More informationWTX120. Legal-for-trade industrial weighing terminal. Special features. Data sheet
WTX120 Legal-for-trade industrial weighing terminal Special features - Connection of up to 8 SG load cells (350 ohm) via plug terminals - Display resolution up to 30,000, legal for trade up to 10,000e
More informationCOMPU-M INTEGRATOR. Instruction Manual PL-516 April Rev. 2.2
COMPU-M INTEGRATOR Instruction Manual PL-516 April 2001 33455160 Rev. 2.2 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product
More informationFlow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI
Overview The MAG 6000 I/6000 I Ex de is a microprocessorbased transmitter with a buildin alphanumeric display in several languages. The transmitters evaluate the signals from the associated electromagnetic
More informationWeighing Electronics SIWAREX - PLC-based weighing electronics
Overview Design is a compact technology module in SIMATIC S7-100 and allows direct connection to S7-100 components via a sliding connector. The rail mounting of the 70 mm (.76 inch) wide weighing module
More informationLevel Measurement Continuous level measurement - Ultrasonic transmitters
Overview Configuration is a short-range integrated ultrasonic level transmitter. This general purpose, 2-wire, to 20 ma loop powered transmitter is ideal for liquids, slurries, and bulk materials in open
More informationFlow Measurement SITRANS F US Inline
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More informationEU Type Examination Certificate
EU Type Examination Certificate No. DK0199.486 Revision 1 DAD14x.y NON-AUTOMATIC WEIGHING INSTRUMENT Issued by DELTA Danish Electronics, Light & Acoustics EU - Notified Body No. 0199 In accordance with
More informationEC Type-Approval Certificate
EC Type-Approval Certificate No. DK 0199.492 FT-10 / FT-10 Fill / FT-10 Flow NON-AUTOMATIC WEIGHING INSTRUMENT Issued by DELTA Danish Electronics, Light & Acoustics EU - Notified Body No. 0199 In accordance
More informationEC Type Examination Certificate
EC Type Examination Certificate No. DK 0199.514 FT-10 Fill AUTOMATIC GRAVIMETRIC FILLING INSTRUMENT Issued by DELTA Danish Electronics, Light & Acoustics EU - Notified Body No. 0199 In accordance with
More informationFlow Measurement. SITRANS F US Clamp-on. SITRANS FUG1010 (Gas) 4/336 Siemens FI Overview
Flow Measurement Siemens G 2010 Overview pplication SITRNS FUG1010 is ideal for most natural and process gas industry applications, including: Checkmetering llocation Flow survey verification Lost and
More informationSITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195
Overview MASS 6000 is based on the latest developments within digital signal processing technology engineered for high performance, fast flow step response, fast batching applications, high immunity against
More informationFlow Measurement SITRANS F C
Overview MASS 6 is based on digital signal processing technology engineered for high performance, fast flow step response, fast batching applications, high immunity against process noise, easy to install,
More informationLevel Measurement Continuous level measurement - Ultrasonic transmitters
Overview Configuration is a short-range integrated ultrasonic level transmitter. It is intrinsically safe (ATEX, CSA, FM, IECEx, NEPSI), 2 wire, to 20 ma loop powered, ideal for liquids, slurries, and
More informationMIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET
& DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)
More informationFlow Measurement SITRANS F US Inline
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More informationQ-LINK SMART BYPASS. SIZING INFORMATION TABLE Q-Link Variable Frequency Drive - 3-Phase 208 VAC 230 VAC VAC HP FLA HP FLA HP FLA TECHNOLOGIES
Q-LINK SMRT BYPSS 1 28, 208 480VC, 3Ø UL Type 1 Enclosure The is an integrated solution for critical applications without compromising for communications and motor protection. Unlike traditional bypasses,
More informationMIC-2 Multi-instrument DATA SHEET
Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules
More informationFlow Measurement SITRANS F M
low sensor MAG P Overview Mode of operation The flow measuring principle is based on araday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage
More informationINTECONT Tersus Mass flow rate measurement
INTECONT Tersus Mass flow rate measurement Maximum reliability Legal-for-trade ability accuracy Automated commissioning and adjustment Cost-effective compact system Application The INTECONT Tersus control
More informationFlow Measurement SITRANS F US Clamp-on
Overview SITRANS FUG1010 clamp-on non-intrusive ultrasonic flow transmitter is ideal for natural and process gas applications, including checkmetering, allocation, production, storage and gas fired power
More informationMeasuring Amplifier DMS 50 Weight - Force - Pressure - Torque with strain gauges
+49-(0)40-670 73-0 Fax +49-(0)40-670 73-288 info@martens-elektronik.de www.ghm-messtechnik.de Measuring mplifier DMS 50 Weight - Force - Pressure - Torque with strain gauges Features M Bridge sensitivity
More informationA0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT
A0-10 ANALOG OUTPUT Instruction Manual April 2001 NALOG OUTPUT Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on araday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationCharacteristics and functioning
Characteristics and functioning 1/1 enod4-t Characteristics and functioning 216702-C_NU-eNod4T-ETH-E-0314 2/2 enod4-t Characteristics and functioning 216702-C_NU-eNod4T-ETH-E-0314 1 ENOD4 PRODUCT RANGE...
More informationCharacteristics and functioning
Characteristics and functioning 1/27 enod4-c Characteristics and functioning NU-eNod4C-ETH-E-1014_216706-A 1 ENOD4 PRODUCT RANGE... 4 1.1 General presentation... 4 1.2 Versions and options... 4 1.2.1 Versions...
More informationLAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description
Description LAUREL ELECTRONICS, INC. Features Laureate Digital Panel Meter for Load Cell & Microvolt Input 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999
More informationLevel Measurement Continuous level measurement - Ultrasonic transducers
Overview transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing effect reduces blanking distance Optional foam
More informationPN DN FIG. 660D-BATT+670D-BATT 661D-BATT+670D-BATT SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE KAT KAT-06...
1 2 BATTERY-OPERATED WATER METER MAG 8000 MAG 8000 is a comprehensive meter which intelligent information and high performance measurement as well as the easy to install concept take cost of ownership
More informationMeasurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/221
Siemens AG 2011 Flow Measurement Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track)
More informationThe IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.
IQ300 Wall Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high
More informationFlow Measurement SITRANS F C
Overview MASS 6 is based on digital signal processing technology engineered for high performance, fast flow step response, fast batching applications, high immunity against process noise, easy to install,
More informationINTECONT PLUS for Measuring Systems
INTECONT PLUS for Measuring Systems % Compact weighing electronics for continuous measuring systems % Integrated display and control panel % Optimal communication structures thanks to modular fieldbus
More informationBACnet. b3810 Series Local Controllers
BACnet b380 Series Local Controllers The Andover Continuum TM b380 series controllers are designed for control of Air Handling Units, Roof Top Units, and other mechanical plant equipment. 0 Features Choose
More informationCERTIFICATE of EU TYPE-APPROVAL
CERTIFICATE of EU TYPE-APPROVAL No. DK 0199.183 Revision 1 Boston / Vegas / California / Kansas NON-AUTOMATIC WEIGHING INSTRUMENT Issued by DELTA Danish Electronics, Light & Acoustics EU - Notified Body
More informationLCI User Manual mantracourt.com
LCI User Manual mantracourt.com LCI Load Cell Junction Box with Fault Monitor Contents Chapter 1 Introduction to the LCI... 2 Chapter 2 Installing the LCI... 3 Chapter 3 Setting up the LCI... 4 Sequence
More informationAndover ContinuumTM Infinet II
Andover ContinuumTM Infinet II i2920 System Controllers The Andover Continuum Infinet II i2920 System Controller is designed to meet the needs of your most demanding control and monitoring applications
More informationThe IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.
IQ240 Panel Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high
More informationCommunication settings: Network configuration can be done via the Anybus IP configuration setup tool or via the on board Web server
SmartLinx EtherNet/IP instruction and use APPLICATION GUIDE Objective: Show the user how to configure and use an EtherNet/IP SmartLinx communication module. AG082415 While every effort was made to verify
More informationMIC-2 MKII, Multi-instrument DATA SHEET
MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)
More informationEngineering Specifications HydroRanger 200. Multi-Functional Level Control System
General Engineering Specifications HydroRanger 200 Multi-Functional Level Control System Scope This section describes the requirements for a multi-functional level controller system. Under this item, the
More informationEZ-ZONE RM MULTI-LOOP CONTROLLER
EZ-ZONE MULTI-LOOP CONTROLLER EZ-ZONE Introduces High-Density s Which Integrate Temperature, Process, Limit and Power Control from 1 to 152 Loops The EZ-ZONE controller family simplifies thermal system
More informationAndover ContinuumTM Infinet II
Andover ContinuumTM Infinet II The i80 Series controllers are designed for control of Air Handling Units, Roof Top Units, and other mechanical plant equipment. Features 0 Choose the i80 model with the
More informationAndover ContinuumTM. b3850 Series Terminal Controllers
TM b3850 Series Terminal Controllers The TM b3850 series controllers are native BACnet controllers that communicate on an RS-485 field bus as Master devices using the MS/TP BACnet protocol. 02 Features
More informationLCI Load Cell Junction Box with Fault Monitor
LCI Load Cell Junction Box with Fault Monitor User Manual www.mantracourt.co.uk The LCI Load Cell Failure Alarm Manual Chapter 1 Introduction to the LCI...2 Chapter 2 Installing the LCI...3 Figure 2.1
More informationPresented By. NicolScales.com Contact Us
Presented By Dallas Ft Worth Austin Houston NicolScales.com 800.225.8181 Contact Us Nicol Scales & Measurement is an ISO Accredited Calibration Company that has provided calibration, repair and sales of
More informationThermo Scientific AquaPro Multi-Input Intelligent Process Analyzer
Thermo Scientific AquaPro Multi-Input Intelligent Process Analyzer Thermo Scientific AquaPro provides accurate, user-friendly in-line monitoring of process applications from power generation to municipal
More informationSeries TFXB Ultra. Transit Time Ultrasonic Flow Meter, Clamp-on, Liquid, Single-Channel
Series TFXB Ultra Transit Time Ultrasonic Flow Meter, Clamp-on, Liquid, Single-Channel Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic flow measurement transmitter
More informationWeight controller Maxxis 5
Weight controller For maximum weighing process control The innovative weight controller is suitable for the most diverse of applications from multi-component dosing to one-component filling and counting
More informationAiRanger DPL Plus. Dual-Point Ultrasonic Level Measurement System
AiRanger DPL Plus Dual-Point Ultrasonic Level Measurement System Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic dual-point level scanner controller with transceiver
More informationLine A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.
Line A Inverse parallel scrs Load a Line B FUSION SCR POWER O delta CONTROLLERS Line c inverse parallel scrs Load C FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC or DC Output AC Models: 50-1200
More informationLevel instruments. Point level measurement - Capacitance switches. Pointek CLS300 5/31
Level instruments Overview The unique modular design of the provides a wide range of configurations, process connections, extensions and approvals to meet the temperature and pressure requirements of specific
More informationUSER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020
USER MANUAL MULTI COLOR MODEL : ARC2020 ACCSYS ELECTRONICS 140/6B, GOLDEN INDUSTRIAL ESTATE, JAWAHARLAL NEHRU ROAD, GERUGAMBAKKAM, CHENNAI - 600122 Tel: 044 60505599 / 60505511 E-mail : sales@accsyselectronics.com
More informationMICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS
The MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS Mighty-5 DPM MODELS Micro-P & Mighty-1 Mighty-1 Micro-P ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters and
More informationFlow Measurement SITRANS F C
Overview Benefits It is compact and light, fitting neatly into dense piping arrangements Easy maintenance because modules can be exchanged rapidly Effective separation of measurement from plant vibration
More informationNetwork configuration can be done via the Anybus IP configuration setup tool or via the on board Web server.
SmartLinx EtherNet/IP instruction and use Objective: Show the user how to configure and use a EtherNet/IP SmartLinx communication module. AG052813 While every effort was made to verify the following information,
More informationUSER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series
USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series TEMPSEN DEVICES Plot No : 2&3, Balaji Nagar, 4 th Street, Mettukuppam, Thoraipakkam, Chennai-600097 Tele fax : +91-44-24581758,Mobil
More informationTPE 1464 Series Pressure Transducer
TPE 1464 Series Pressure Transducer Description The KMC TPE 1464 series of pressure transducers incorporate a gauge pressure transmitter featuring low hysteresis, excellent repeatability, and longterm
More informationMulti-Point Gas Detection and Control System
Multi-Point Gas Detection and Control System DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control system for various gas, temperature and humidity detection, control and
More informationBACnet. b3867 Terminal Controllers
BACnet b3867 Terminal Controllers The Andover Continuum TM b3867 is a native BACnet controller that communicates on an RS-485 field bus as a Master device using the MS/TP BACnet protocol. 02 Features Product
More informationLCp-100 Weight Indicator/Transmitter
Precision Force and Weight Measurement Technologies LCp-100 Weight Indicator/Transmitter Process Applications: Mix Tanks Blenders Reactors Product Description Hardware Features 1 Million Count Resolution,
More informationMicro Motion Model 2200S 2-Wire Transmitter with MVD Technology
Product Data Sheet PS-001094, Rev. C September 2009 Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology The Micro Motion Model 2200S 2-wire transmitter enables the use of reliable and accurate
More informationFlow Measurement SITRANS F M. Transmitter MAG 5000/6000 4/33. Overview
Siemens G 2010 Flow Measurement Transmitter MG 5000/6000 Overview Design The transmitter is designed as either IP67 NEM X/6 enclosure for compact or wall mounting or 19" version as a 19 insert as a base
More information