1 OIT-3165 Operator Interface Installation Manual Information furnished by EMERSON Motion Control is believed to be accurate and reliable. However, no responsibility is assumed by EMERSON Motion Control for its use. EMERSON Motion Control reserves the right to change the design or operation of the equipment described herein and any associated motion products without notice. EMERSON Motion Control also assumes no responsibility for any errors that may appear in this document. Information in this document is subject to change without notice. P/N Rev.: A1 Date: December 31, EMERSON Motion Control. All Rights Reserved.
2 OIT-3165 Operator Interface Installation Manual 1998 EMERSON Motion Control. All Rights Reserved. Document Number: No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of EMERSON Motion Control. EMERSON Motion Control is a registered trademark of EMERSON Motion Control. EMERSON Motion Control is a subsidiary of Emerson Electric Company. Printed in U.S.A. December 1998, Revision A1 Microsoft and Windows are registered trademarks of Microsoft Corporation. Maple Systems and OITware are trademarks of Maple Systems, Inc. These instructions do not purport to cover all details or variations in equipment, nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the Purchaser s purposes the matter should be referred to the local Authorized Dealer or EMERSON Motion Control s Service Department. This document has been prepared to conform to the current released version of the hardware and software system. Because of our extensive development efforts and our desire to further improve and enhance the product, inconsistencies may exist between the product and documentation in some instances. Call your customer support representative if you encounter an inconsistency. 2
3 Customer Service EMERSON Motion Control 1365 Park Road Chanhassen, Minnesota U.S.A. EMERSON Motion Control offers a wide range of services to support our customer s needs. Listed below are some examples: Service Support (612) service@emersonemc.com EMERSON Motion Control s products are backed by a team of professionals who will service your installation wherever it may be. Our customer service center in Minneapolis, Minnesota is ready to help you solve those occasional problems over the telephone. Our customer service center is available 24 hours a day for emergency service to help speed any problem solving. Also, all hardware replacement parts, should they ever be needed, are available through our customer service organization. When you call, please be at your computer, have your documentation in hand, and be prepared to provide the following information: Product version number, found by choosing About from the Help menu. The type of controller or product you are using. Exact wording of any messages that appear on your screen. What you were doing when the problem occurred. How you tried to solve the problem. Need on-site help? EMERSON Motion Control provides service, in most cases, the next day. Just call EMERSON s customer service center when on-site service or maintenance is required. Training Services (612) EMERSON Motion Control maintains a highly trained staff of instructors to familiarize customers with EMERSON Motion Control s products and their applications. A number of courses are offered, many of which can be taught in your plant upon request. 3
4 OIT-3165 Operator Interface Installation Manual Application Engineering (612) An experienced staff of factory application engineers provides complete customer support for tough or complex applications. Our engineers offer you a broad base of experience and knowledge of electronic motion control applications. Bulletin Board System (612) EMERSON Motion Control maintains a BBS which provides you access to software updates, and technical information and services. Communications protocol:300 to 28,800 baud, N, 8, 1 FAX (612) You can FAX questions and comments to EMERSON Motion Control. Just send a FAX to the number listed above. Internet Website Sales (612) sales@emersonemc.com 4
5 Document Conventions Manual conventions have been established to help you learn to use this manual quickly and easily. As much as possible, these conventions correspond to those found in other Microsoft Windows documentation. Menu names and options are printed in bold type: the File menu. Dialog box names begin with uppercase letters: the Axis Limits dialog box. Dialog box field names are in quotes: Field Name. Button names are in italic: OK button. Source code is printed in Courier font: Case ERMS. In addition, you will find the following typographic conventions throughout this manual. bold italic This ALL CAPITALS SMALL CAPS KEY1+KEY2 example: (Alt+F) KEY1,KEY2 example: (Alt,F) Represents Characters that you must type exactly as they appear. For example, if you are directed to type a:setup, you should type all the bold characters exactly as they are printed. Place holders for information you must provide. For example, if you are directed to type filename, you should type the actual name for a file instead of the word shown in italic type. Directory names, file names, key names, and acronyms. Non-printable ASCII control characters. A plus sign (+) between key names means to press and hold down the first key while you press the second key. A comma (,) between key names means to press and release the keys one after the other. 5
6 OIT-3165 Operator Interface Installation Manual Safety Instructions General Warning Failure to follow safe installation guidelines can cause death or serious injury. The voltages used in the product can cause severe electric shock and/or burns, and could be lethal. Extreme care is necessary at all times when working with or adjacent to it. The installation must comply with all relevant safety legislation in the country of use. Qualified Person For the purpose of this manual and product, a qualified person is one who is familiar with the installation, construction and operation of the equipment and the hazards involved. In addition, this individual has the following qualifications: Is trained and authorized to energize, de-energize, clear, ground and tag circuits and equipment in accordance with established safety practices. Is trained in the proper care and use of protective equipment in accordance with established safety practices. Is trained in rendering first aid.! WARNING For the purpose of this manual and product, Warning indicates death, severe personal injury or substantial damage CAN result if proper precautions are not taken.! CAUTION For the purpose of this manual and product, Caution indicates minor personal injury or property damage CAN result if proper precautions are not taken. NOTE: For the purpose of this manual and product, Note: indicates information about the product or the respective part of the manual which is essential to highlight. 6
7 OIT-3165 Operator Interface Table of Contents Control Panel Design Guidelines Control Panel Grounding Power Supply Selection OIT Cable Routing Other Steps to Improve Noise Immunity OIT Installation Create Custom Slide-In Legend Prepare Panel for OIT Mounting Mount OIT to Panel Connect OIT to Power Connect OIT to PLC/Host OIT Configuration Wiring Connect OIT to PC for Configuration Cable Diagrams Custom Keypad Slide-In Legends Predefined Keypad Templates Blank Legend for Photocopying Creating a Computer-Generated Slide-In Legend Installing a Slide-In Legend OIT-3165 Hardware Specifications OIT-3165 Dimensions
8 OIT-3165 Operator Interface Control Panel Design Guidelines Note: In this manual, the term "PLC" refers to either a PLC, Motion Controller or Servo Drive. Note: The OITware-200 Configuration Software is a product of Maple Systems, Inc. Pay careful attention to the placement of system components and associated cable routing. These items can significantly enhance the performance and integrity of your control application. Control Panel Grounding The control panel should be connected to a good, high-integrity earth ground both for safety considerations and shielding purposes. This must be a reliable earth ground with a low-resistance path. The ideal earth ground would be a copper grounding rod located close to the OIT and the control panel. Hinged doors on control panels do not provide a long term electrical connection to the rest of the enclosure. Corrosion develops over time and prevents good electrical contact. For this reason, a separate wire braid should be installed from the hinged control panel to the rest of the enclosure. 3
9 OIT-3165 Operator Interface Installation Manual Power Supply Selection The power supply used to power the OIT should have an output between +12 and +30 VDC. The voltage should measure between +12 and +30V at the OIT between Pins 1 and 2 of the power connector. A 24 VDC, 1.2 amp linear power supply dedicated to the OIT is recommended. The power cable for the OIT should be 18AWG 2-conductor wire with a shield wire and protective shield (foil or braid). The shield of the OIT power cable must be connected to earth ground at both ends of the cable. Please refer to the Connect OIT to Power section for more information. A power line filter installed at the AC input to the OIT power supply is highly recommended as a safeguard against conducted RF noise, which is often present on factory power lines. The wires connecting the output of the power line filter to the power supply should be kept as short as possible to minimize any additional noise pickup. The case of the power line filter should be connected to a quiet earth ground. The power line filter should have a current rating of at least three amps with common mode and differential mode attenuation. The power supply that provides power to the OIT should not be used to power switching relays or solenoids unless noise filter caps are connected to each relay. 4
10 Control Panel Design Guidelines OIT Cable Routing Always route the OIT communication cable and power cable away from any AC voltage or PLC/host control wires. Never bundle the OIT cables together with 120 VAC power wires or with relay wiring. Try to keep at least 8 inches (20.32 cm) of separation between the OIT cables and other power wiring. If voltages greater than 120 VAC are used in the system, greater separation is required. If the OIT cables must come near AC wiring, make sure they cross at 90 degrees. Running AC power wires in a separate grounded conduit is the preferred method for electrical noise reduction. Keep the lengths of the OIT cables as short as possible. Do not coil excess cable and place it next to AC powered equipment. Other Steps to Improve Noise Immunity Always install the OIT s rear cover. This provides a shield against electrical noise which can be generated in the control panel by relays, motors, power lines, and/or high frequency equipment. Ensure that all rear cover mounting screws are properly secured. Any equipment used in the enclosure that operates at high frequency or high current levels can be covered with a grounded metal shield. 5
11 OIT-3165 Operator Interface OIT Installation It is necessary to follow all installation procedures described in this chapter for electrical noise immunity. Your EMERSON Motion Control OIT is designed to connect easily to your PLC. External connectors provide quick connection for power and communications wiring. There is one serial port with an RJ-45 shielded jack. This port is used to connect to the PLC and to configure the OIT. A separate three-position terminal block is supplied to provide power to the OIT. Create Custom Slide-In Legend Please refer to the Custom Keypad Slide-in Legends section for details. Prepare Panel for OIT Mounting The OIT-3165 is mounted to a control panel from the front. For a proper NEMA 4/12 seal, you will need: A panel with a maximum thickness of inches (3.2 mm). A panel with a minimum thickness of 16-gauge (0.059 inches; 1.5 mm) steel or 10-gauge (0.102 inches; 2.6 mm) aluminum. Thinner panels may bow between the mounting studs, requiring the use of a stiffener on the rear. The surface of the panel, where the panel comes into contact with the gasket, must be free of scratches, pits, and other features that prevent the gasket from sealing properly. 7
12 OIT-3165 Operator Interface Installation Manual The diagram below shows the dimensions of the panel cutout required for proper installation. The panel cutout should be cleaned and deburred before the OIT is installed. 8
13 OIT Installation Mount OIT to Panel 1. Gently position the OIT with the studs through the panel mounting holes. 2. Secure the OIT by installing the four #6-32UNC mounting nuts using a 5/16 inch socket wrench or nut driver. 9
14 OIT-3165 Operator Interface Installation Manual! CAUTION Do not torque the 4 mounting nuts to over 15 pound-inches. Over torquing can strip the threads or pull the studs loose. RE-INSTALLING: Because the gasket will take a set to the panel, be sure to re-install any OIT to the same panel cutout when a NEMA 4/12 seal is required. Connect OIT to Power The power cable for the OIT should be 18AWG 2-conductor wire with a shield wire and protective shield foil. Note: The power connector on the OIT has M3 slotted screws. 10
15 OIT Installation Connect OIT to PLC/Host Each PLC/host supported by the OIT-3165 has its own wiring requirements. EMERSON Motion Control offers pre-constructed OIT-to-PLC communication cables for communicating with E Series drives and AXIMA multi-axis controllers. They are built and tested for high reliability and are strongly recommended. 1. Connect the RJ-45 plug end of the communication cable into the serial port on the OIT. 11
16 OIT-3165 Operator Interface Installation Manual 2. Ensure that the locking tab has secured the plug. 3. Route the communication cable to the PLC/host. Refer to the OIT Cable Routing section for more information. 4. Connect the other end of the cable to the PLC/host and tighten the cable screws. 12
17 OIT-3165 Operator Interface OIT Configuration Wiring The OIT-3165 must be configured for a particular protocol before use. The OITware-200 software (used on a computer with Windows 3.1 or later) is used for OIT configuration. Connect OIT to PC for Configuration To configure the OIT-3165 using the OITware-200 Configuration Software, remove the PLC/host cable from the serial port on the OIT and connect the OIT to the computer using an RS-232 serial communications cable (P/N OIT-PC- 232-XXX, EMERSON Motion Control). The configuration cable should be connected to the proper COM port on your computer, then attached to the serial port on the OIT. See Figure 7 below for serial port pin assignments. Figure 1 Cable, OIT-3165 to PC, RS-232, OIT-PC-232-XXX Figure 2 Cable, OIT-3165 to EN Drive, RS-232, OIT-EN-232-XXX 13
18 OIT-3165 Operator Interface Installation Manual Figure 3 Cable, OIT-3165 to EN Drive, RS-485, OIT-PC-485-XXX Figure 4 Cable, OIT-3165 to AXIMA, RS-485, OIT-AX-485-XXX 14
19 OIT Configuration Wiring Cable Diagrams 15
20 OIT-3165 Operator Interface Installation Manual 16
21 OIT-3165 Operator Interface Custom Keypad Slide-In Legends The OIT-3165 has a graphic overlay covering the keypad. This overlay contains a clear window that allows you to insert your own legend to customize the keypad s text, colors, and graphics. This legend can be inexpensively made and is environmentally sealed when installed. The slide-in legend can be made on any non-glossy stock between inches (0.1 mm) and inches (0.2 mm) thick by using any of the following methods: Photocopy one of the predefined keypad templates. Photocopy the blank legend and hand illustrate. Use the dimensions to create a computer generated legend. Predefined Keypad Templates If you have chosen one of the predefined keypad templates in OITware-200, you can photocopy the corresponding slide-in legend from Figure 8. 17
22 OIT-3165 Operator Interface Installation Manual 18
23 Custom Keypad Slide-In Legends Blank Legend for Photocopying The blank legend in Figure 9 can be photocopied and hand illustrated. 19
24 OIT-3165 Operator Interface Installation Manual When photocopying: Use only non-glossy stock which is inches ( mm) thick. Check photocopy accuracy with the printed check dimension. When illustrating: Use the tick marks to locate the switch centers. Refer to the computer generated legend dimensions if unsure. Note: Pressing the center of the switch is critical for switch actuation. Recommended key size is inches [12.7 mm] square. Background colors should extend to the solid lines. All text and graphics should be 0.07 inches [1.78 mm] within the solid lines. Note: Do not affix anything to the legend using glue, tape, stickers, etc. Creating a Computer-Generated Slide-In Legend The dimensions in Figure 10 can be used to create a computer generated legend. When creating: Dimensions are in inches [mm]. Recommended key size is inches [12.7 mm] square. Note: Pressing the center of the switch is critical for switch actuation. Background colors should extend to the upper and lower edges of the legend and to the 2 vertical lines marked BACKGROUND. All text and graphics should be within the dashed rectangle. When printing: Use only non-glossy stock which is inches ( mm) thick. 20
25 Custom Keypad Slide-In Legends Check printing accuracy with the printed check dimension. Installing a Slide-In Legend To replace the factory installed legend with your own: 1. Ensure all paints, inks and fixative are thoroughly dry and will not transfer. 2. Place the unit face down on a clean protective surface. 3. Locate the legend access slot along the right side of the cover. 4. Remove the tape from the existing legend and then pull the legend out. 5. Slide in the new legend (refer to Figure 11). Note: be gentle avoid wrinkling, which makes it hard to push the legend in if the legend moves around too much, put a curl in the paper The legends are made long to facilitate removal. 21
26 OIT-3165 Operator Interface Installation Manual 6. Once installed, tape the end of the legend to the cover to secure it. 22
27 OIT-3165 Operator Interface OIT-3165 Hardware Specifications Mechanical Material: Aluminum sealed to NEMA 4/12 when panel mounted Mounting: Panel Wiring: Unit is field-wired by user to external power plug and shielded RJ-45 communications connectors Weight: 1 pound (0.45 kg) Environmental Operating Temp: +32 to +122 F (0 to +50 C) Storage Temp: -4 to +158 F (-20 to +70 C) Electric Noise Immunity (pending CE approval) Emissions: EN55011 (Group 1, Class B) Generic commercial, light, and heavy industrial environments EN Generic domestic and light industrial environments EN Generic heavy industrial environment Immunity: EN Generic domestic and light industrial environments EN Generic heavy industrial environment Power Requirements Input Voltage: 12 to 30 VDC Power Usage: 2.5 watts typical Display Display Type: Backlit Liquid Crystal Display (LCD) 5 x 7 dot matrix with cursor Display Character Size: 2 lines of 20 characters, 0.19 inches (4.8 mm) high Display Viewing Angle: Approximately 90 degrees Keypad Key Type: Membrane switch with custom legending (all keys) Feedback: Audible Layout: 24 user-definable keys arranged in 3 rows 23
28 OIT-3165 Operator Interface Installation Manual Operational Life: Three million operations Communications Serial Port: RS-232, RS-422, or RS-485 Baud Rates: 300, 600, 1200, 2400, 4800, 9600, or 19.2k Internal Features Memory: 128K x 8 Flash PROM for firmware protocol and configuration data no battery required 24
29 OIT-3165 Hardware Specifications OIT-3165 Dimensions 25
PanelView Plus/VersaView CE Terminals and Display Modules
Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3
More informationGraphic Display Unit/Human Machine Interface M 3919A
SYNCHRONIZING Graphic Display Unit/Human Machine Interface M 3919A Graphic Display Unit (GDU) and Touch Screen Human Machine Interface (HMI) for Communicating with One or Two M-4272 Digital Motor Bus Transfer
More informationUSP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10
UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for
More informationGraphic Display Unit/Human Machine Interface M-3909
SYNCRHONIZING Graphic Display Unit/Human Machine Interface M-3909 Graphic Display Unit (GDU) and Touch Screen Human Machine Interface (HMI) for Communicating with One or Two M-4272 Digital Motor Bus Transfer
More informationAdapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout
Installation Instructions Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout Catalog Numbers 2711-NR5T, 2711P-RAT12E2 Topic Page About This Publication 1 Important User Information 2 About
More informationInstallation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.
Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable
More informationThis guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).
Vision OPLC Installation Guide Models 230/260/280/290 (Non-color Screens) This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). General Description Vision OPLCs
More informationCOOPER POWER SERIES. RS-485 digital communications accessory board installation and operation instructions. Voltage Regulators MN225074EN
Voltage Regulators MN225074EN Effective March 2017 Supersedes January 2012 (S225-40-7) RS-485 digital communications accessory board installation and operation instructions COOPER POWER SERIES DISCLAIMER
More information*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition).
PowerCore Model MPC-20 Installation Manual *Approved by CSA for non-hazardous locations (Group Safety Publication IEC 61010-1 Third Edition). Products covered in this document comply with European Council
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UIA-0402N Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for
More informationIO-AO6X I/O Expansion Module 6 Isolated Analog Outputs
IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UID-0808THS Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for
More informationUniStream HMI Panel. CPU-for-Panel
UniStream HMI Panel Installation Guide USP-070-B10,USP-104-B10, USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for industrial automation. This
More informationA1. Multilin EPM 4600 Meter Displays DIS3500/DIS5700. Quick Start Guide. GE Digital Energy
GE Digital Energy Multilin EPM 4600 Meter Displays DIS3500/DIS5700 Quick Start Guide Product version: 1.0x GE publication code: 1601-0500-A1 (GEK-119644) 1601-0500-A1 Copyright 2014 GE Multilin Inc. All
More informationSeries Amp Pad Mount Quick Connect Input and Output Power Panels
Series 300 2000-4000 Amp Pad Mount Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury.
More informationAXIMA Installation Manual
AXIMA Installation Manual P/N 400328-00 Rev.: A1 Date: October 31, 1997 1997 EMERSON Motion Control. All Rights Reserved. P/N 4002 AXIMA Installation Manual Information furnished by EMERSON Motion Control
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UID-0808R, UID-0808T, UID-1600,UID-0016R, UID-0016T Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides
More informationThe information in this chapter will enable you to: Understand the product's basic functions & features
C H A P T E R ➀ Chapter Objective Product Description The information in this chapter will enable you to: Understand the product's basic functions & features Introduction The RP240 is designed to operate
More informationInstallation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.
Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UIS-04PTN Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for
More informationTemperature. Power requirements. Weight. Dimensions
Installing the Tracer Summit BMTX Building Control Unit Ordering numbers: BMTX001AAB000, BMTX001AAB010, BMTX001AAB001, BMTX001AAB011, BMTX001BAB000, BMTX001BAB010, BMTX001BAB001, BMTX001BAB011, BMTX001DAB000
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Wide Modules Installation Guide UID-W1616R, UID-W1616T Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide
More informationVapor Monitor Interface Module
Manual No: 577013-951 Revision: A Vapor Monitor Interface Module Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the
More information* * Agilent Power Distribution Unit (PDU) Installation Guide
Agilent Power Distribution Unit (PDU) Installation Guide For use with Agilent PDU kits and PDU installation kits for Agilent instrument racks June 2008 Edition 7 E0608 *5000-0039* 5000-0039 Notice The
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-COM Modules Installation Guide UAC-01RS2,UAC-02RS2,UAC-02RSC Uni-COM is a family of communication modules that are compatible with the UniStream control platform. This guide provides basic installation
More informationSeries Amp Quick Connect Input and Output Power Panels
Series 300 1200-1600 Amp Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury. WARNING is
More informationInView Marquee Message Display
Installation Instructions InView Marquee Message Display Introduction These instructions show how to change the serial address and how to mount InView series signs with NEMA Types 4, 4X, and 12 enclosures.
More information170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0
170 ADM 850 10 10 to 60 VDC Module Base / 170 ADO 830 30 6 Pt. Relay Out Module Base Version 1.0 31005197 00 Safety Information NOTICE Read these instructions carefully, and look at the equipment to become
More informationManual No: Revision: F. Relay Output Modules. Installation Guide
Manual No: 576013-614 Revision: F Relay Output Modules Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties
More informationVision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120.
Vision OPLC Installation Guide Vision120 This guide provides basic information for Unitronics Vision120. General Description V120 OPLCs are micro-oplcs, rugged programmable logic controllers that comprise
More informationSINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS
SINAMICS G130 Operating Instructions 03/2013 SINAMICS s Safety information 1 General information 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5
More informationHigh Frequency Power Supply Board IS200HFPRG_A
g GEI-100312 GE Industrial Systems High Frequency Power Supply Board IS200HFPRG_A Safety Symbol Legend Indicates a procedure or condition that, if not strictly observed, could result in personal injury
More informationInstalling Your 1394 Drive Interface Module
Installation Instructions Installing Your Drive Interface Module (Catalog Number -DIM) Introduction This publication provides installation instructions for adding the Drive Interface Module to your system.
More informationAltivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216
Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216 Instruction Bulletin 30072-452-48 Retain for future use. 30072-452-48 Altivar 61/71 Heatsink Fan Kits VZ3V1212 and VZ3V1216
More informationGV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000
GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000 Instruction Manual D2-3390-2 The information in this manual is subject to change without notice. Throughout this manual, the
More informationModels beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)
Models beginning with 2M, 2L or 2X Series 2000 Multiple Meter Units (MMUs) Product Description Technical Specifications Installation Instructions February 28 th, 2013 List of Figures...2 List of Tables...2
More informationUniStream CPU-for-Panel
UniStream CPU-for-Panel Installation Guide USC-P-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for industrial automation. This guide provides basic
More informationCOOPER POWER SERIES. Input/Output (I/O) module installation instructions. Voltage Regulators MN225067EN
Voltage Regulators MN225067EN Effective November 2016 Supersedes June 2014 (S225-70-13) COOPER POWER Input/Output (I/O) module installation instructions SERIES DISCLAIMER OF WARRANTIES AND LIMITATION OF
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Vision OPLC V350-35-R34/V350-J-R34 Installation Guide The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder
More informationEXPRESS SETUP. PanelMate 1700 Series PanelMate Power Pro. Cutler-Hammer
EXPRESS SETUP PanelMate 1700 Series PanelMate Power Pro Cutler-Hammer Installation Unpacking Carefully remove all equipment from the packing cartons and inspect all parts for damage in shipment. Check
More informationTRC-190 User s Manual
First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement
More informationPS/IO Circuit Board Retrofit
S&C 6800 Series Automatic Switch Controls PS/IO Circuit Board Retrofit Table of Contents Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this Instruction Sheet....
More informationModel 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit
More informationInstallation Instructions
Installation Instructions (Cat. No. 1794-TBN) 6 1 5 9 4 2 3 10 6 7 8 Component Identification 1 Female flexbus connector 2 Terminal base unit (1794-TBN) 3 Male flexbus connector 4 Keyswitch Set to the
More informationUser Interface Terminal for nvent RAYCHEM NGC Systems Installation Instructions DESCRIPTION TOOLS REQUIRED. Nonhazardous Locations LR67275
NGC-UIT-ORD User Interface Terminal for nvent RAYCHEM NGC Systems Installation Instructions DESCRIPTION The nvent RAYCHEM NGC-UIT-ORD is a panel mounted display used in conjunction with other approved
More informationTRC-190 User s Manual
User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only
More informationClipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems
Clipsal Bus Couplers Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems Instruction Bulletin Retain for future use. Clipsal Bus Couplers 63249-420-236A2 Instruction
More informationF1000 User's Manual. (Version: V1.01)
(Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...
More informationINSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B
INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM Doc. 6001051 Rev B Page 2 of 7 Doc 6001051 Rev B IMPORTANT NOTICES The Mini-Key system is a very reliable and easy to use system. However, damage could
More informationMODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT
MODEL INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT A. GENERAL. The Federal Model is a solid-state
More informationShutter Assembly Guide Frame Accessory
Shutter Assembly Guide Frame Accessory SIZE: FS1 3-pole Cat. No.: WLG3SHUT1L For Use With: Circuit Breaker Adapters WLG _ 13 Installation Instructions Instruction No.: 923 99902 176 Danger Peligro Danger!
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Wide Modules Installation Guide UIS-WCB1 Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide as Uni-I/O
More informationPowerFlex 755 Transition Section and Splicing Kit for Floormount Drives and CENTERLINE 2100 Motor Control Centers
Installation Instructions PowerFlex 755 Transition Section and Splicing Kit for Floormount Drives and CENTERLINE 2100 Motor Control Centers Topic Page Introduction, Compatibility 1 Additional Resources
More informationInstallation manual plugs and connectors with screw connection (16/32 A)
EN Installation manual plugs and connectors with screw connection (16/32 60003213 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3
More informationVision OPLC V TR6/V350-J-TR6
Vision OPLC V350-35-TR6/V350-J-TR6 Installation Guide The Unitronics V350-35-TR6/V350-J-TR6 offers the following onboard I/Os: 8 Digital Inputs, configurable via wiring to include 2 Analog (current/voltage)
More informationSolar Combiner Enclosure
Installation Instructions Solar Combiner Enclosure Catalog Numbers 1000-SB006, 1000-SB012 Topic Page Description 1 Important Safety Instructions 3 Nameplate Data 4 Planning for Installation 4 Install the
More informationPowerLogic High Density Metering System 1-Meter Enclosure
PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these
More informationKBMG MULTI-SPEED BOARD
TM INSTALLATION AND OPERATION MANUAL KBMG MULTI-SPEED BOARD KB Part No. 8833 Multi-Speed Board for KBMG Series Regenerative Drive Pending! See Safety Warning on Page 1 The information contained in this
More informationInstallation Guide SMT 2200/3000 VA Input/Output Hardwire Kit
Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit Important Safety Messages SAVE THESE INSTRUCTIONS - This section contains important instructions that should be followed during installation
More informationEX-RC1 Remote I/O Adapter
EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter
More informationThermocouple Input Module Product Specifications and Installation Data
Thermocouple Input Module Product Specifications and Installation Data 1 DESCRIPTION The Horner APG Thermocouple Input Modules allow thermocouple temperature sensors to be directly connected to the PLC
More informationInstallation & Operation Guide
Installation & Operation Guide Direct Digital VAV Controllers KMD-7001/7051 - VAV Terminal Units KMD-7002/7052 - Dual Duct VAV Units KMD-7003/7053 - Fan Induction Units 907-019-01C 1 Introduction This
More informationEP/2 Installation Instructions
1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in
More informationLine reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4
Safety information 1 General 2 SINAMICS SINAMICS G120P Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.6 11/2013 A5E32845290B AA
More informationWiring Best Practices
Form Number F-2825 Issue Date Jan 3, 2018 Revision Date Jun 5, 2018 Wiring Best Practices Selecting, planning, and routing wires. Waterous Company 125 Hardman Avenue South South Saint Paul, MN 55075 (651)
More informationConfigurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English
Configurable Output Distribution 120V / 208V / 240V 60Hz User Manual English TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS.......................... 1 GLOSSARY OF SYMBOLS....................................
More informationPackage Contents. GP Options (Made by Digital)
When connecting the power cord terminals to the GP, be sure the cord has first been unplugged from the power outlet to prevent the possibility of an electric shock. With the exception of changing the GP's
More informationInstallation & Operation Guide
Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1 Introduction This section provides a brief
More information5401 and 5402 Digital I/O Modules
50 and 50 Digital I/O Modules Installation, Operation and Maintenance Setup Manual 5/9/0 Safety Information The information provided in this documentation contains general descriptions and/or technical
More informationUNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN
1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,
More informationThis 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.
Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 (440) 248-0400 Fax: (440) 248-6168 www.keithley.com Model 4200-RM Rack Mount Kit Packing List Introduction NOTE This 4200-RM Rack Mount
More informationSINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS
SINAMICS G130 Operating instructions 03/2011 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Voltage Sensing Module 10 (VSM10) Mechanical installation 3 Electrical installation 4 Technical
More informationFailure to comply with appropriate safety guidelines can cause severe injury or property damage.
Vision OPLC V350-35-B1/V350-J-B1 Installation Guide The Unitronics V350-35-B1/V350-J-B1 offers the following features: I/O configurations can be added via Expansion Modules. General Description V350 OPLCs
More informationUniversal AC Power Source + AC Power Analyzer
User's Guide Universal AC Power Source + AC Power Analyzer Model 380820 Introduction Congratulations on your purchase of the Extech Model 380820. This Universal AC Power Source and AC Power Analyzer can
More informationThe identified danger could cause physical and property damage.
Samba OPLC SM35-J-T20 Installation Guide The Unitronics SM35-J-T20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder Inputs 8 Transistor
More informationAnalyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK
Instruction Sheet PN 51A-54epH/rev J October 2010 ph/orp HART Model 54e ph/orp Analyzer/Controller For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. ESSENTIAL
More information5504 Thermocouple Analog Input Module
550 Thermocouple Analog Input Installation, Operation and Maintenance Setup Manual 5/9/0 Safety Information The information provided in this documentation contains general descriptions and/or technical
More informationS Reclosers Kyle Type VXE Electronic Control SCADA Input/Output Board Installation and Operation Instructions
Reclosers Kyle Type VXE Electronic Control SCADA Input/Output Board Installation and Operation Instructions Cooper Power Systems Service Information S0-6- Applicable to VXE5 reclosers serial number 006
More informationSecured Series: Hub Plus Kit Single Door Controller Package Installation Manual
Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into
More informationLine Impedance Stabilization Network (LISN)
Model 3816/2 Line Impedance Stabilization Network (LISN) User Manual ETS-Lindgren Inc. reserves the right to make changes to any product described herein in order to improve function, design, or for any
More informationLighting Control Panel 16 and 24 INSTALLATION INSTRUCTIONS
PRECAUTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. CAUTION: USE COPPER CONDUCTOR ONLY CAUTION: RISK OF ELECTRICAL SHOCK. To prevent electrical shock, turn off power at the circuit breaker before installing
More informationM215 (M215-60) Safety
M215 QUICK INSTALL GUIDE M215 (M215-60) Safety Important Safety Information This document contains important instructions to use during installation and maintenance of the Enphase M215 Microinverter. To
More informationKinetix 300 Memory Module Programmer
Kinetix 300 Memory Module Programmer Catalog Number 2097-PGMR Topic About the Memory Module Programmer 1 Parts List 3 Batteries Operation 4 Using Memory Module Programmer 6 Switch On/Off Memory Module
More informationFujitsu Stylistic ST4000 Series TABLET DOCK USER S GUIDE
Fujitsu Stylistic ST4000 Series TABLET DOCK USER S GUIDE DECLARATION OF CONFORMITY according to FCC Part 15 Responsible Party Name: Fujitsu PC Corporation Address: 5200 Patrick Henry Drive Santa Clara,
More informationPowerFlex DC Drive Frame B Pulse Transformer Circuit Board
Installation Instructions PowerFlex DC Drive Frame B Pulse Transformer Circuit Board ATTENTION: Only qualified personnel familiar with DC drives and associated machinery should plan or implement the installation,
More informationModel 7705 Control Module
www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be
More informationInstallation Notes TII Model 341 Protector
Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow
More informationEntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation
The EntraGuard Bronze is a residential telephone keypad entry system which allows a homeowner to communicate directly with visitors and provide access by using any phone extension in the home. Because
More informationUser s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual
User s Manual ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1
More informationRelay Contact Output Modules
Relay contact output modules offer dry circuits, that is, circuits without leakage current. Leakage currents are present on solid-state outputs; these currents are capable of energizing highly sensitive
More informationSPiiPlusEC Network Manager Installation Guide November2014 Document Revision: 02
SPiiPlusEC Network Manager Installation Guide November2014 Document Revision: 02 SPiiPlusEC Release Date: November2014 Copyright ACS Motion Control Ltd.2014. All rights reserved. Changes are periodically
More informationMultilin EPM 4600 Metering Solution
GE Digital Energy Multilin EPM 4600 Metering Solution Multi-feed Power and Energy Metering Solution Quick Start Guide GE publication code: 1601-0297-A2 (GEK-119590A) 1601-0297-A2 Copyright 2014 GE Multilin
More informationModel SPDT Switch Module
Model 4148 48 SPDT Switch Module 90900210 Page 1 All technical data and specifications in this publication are subject to change without prior notice and do not represent a commitment on the part of Giga-tronics,
More informationSINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS
SINAMICS G130 Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Voltage Sensing Module 10 (VSM10) Mechanical installation 3 Electrical installation 4 Technical
More informationIndustrial SBU Product User s Manual
Industrial SBU Product User s Manual EUROPEAN COUNTRIES WARNING This is a Class A product. In a domestic environment this product may cause radio interference in which the user may be required to take
More informationSITRANS F. Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel. Introduction 1. Installing/Mounting 2. Hardware Installation Instructions
Introduction 1 Installing/Mounting 2 SITRANS F Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel Hardware Installation Instructions 1/2010 A5E02518333A Revision 04 Legal information Warning notice
More informationInstallation Guide V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ.
Vision OPLC V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ. General Description V1210 OPLCs are programmable logic controllers that comprise a built-in operating
More informationInstallation Job Aid for Ethernet Routing Switch 3600 Series
Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions
More informationInnoMedia Business VoIP ATA Models
InnoMedia Business VoIP ATA Models MTA8328-4, MTA8328-8, MTA8328-24 Quick Installation Guide Important Safety Instructions Protective Earthing Protective earthing is used as a safeguard. This equipment
More informationInstallation Instructions & User Manual
Installation Instructions & User Manual ZONEMASTER PRO AC Panel Transient Voltage Surge Suppressors The Wiremold Company In US: 60 Woodlawn Street, West Hartford, CT 06110 800-621-0049 FAX 860-232-2062