Cobalt 8 Pre-Installation & Site Preparation Guide
|
|
- Bernadette Benson
- 5 years ago
- Views:
Transcription
1 Congratulations on your acquisition of an Escher-Grad Cobalt8 Platesetter. These are some of the finest and most reliable equipment of their kind in the industry. Used properly and in their appropriate environmental conditions, these systems are designed to give you years of productive operation. This document covers essential issues requiring attention and preparation before the delivery and installation of your Escher-Grad equipment. Please read through it carefully and use the Site Preparation Planner and Checklist to help ensure a trouble-free installation (located at the end of this document). Choosing the Right location & Room / Operating Requirements The first step is to find a suitable, clean location within your building for the Escher-Grad imaging system. This would preferably be located on the ground floor to facilitate installation. The foundation must be solid in order to minimize vibration. Also, the surface must be reasonably level. The floor surface should be an insulating material such as linoleum or acrylic tile. Carpet is not recommended, because it generates dust and static electricity. The plate processor, plate rack, air compressor, and a small desk for the Rip Server must be considered during floor planning. The Cobalt 8 Platesetter requires a grounded Amps or Amps line. It also must have a dedicated electrical breaker that cannot be used for any other device. The electrical outlet must be within 60" (152 cm) from the rear left corner of the Platesetter, and should have four available outlets (sockets). Escher-Grad will accommodate any national standards of power plugs, voltages and frequencies. Be sure to indicate your requirements in terms of line voltage and receptacle type on your Purchase Order. Compressed air is required for the Cobalt 8 Platesetter. Escher-Grad provides a stand-alone air compressor that is enclosed in a noise reduction cabinet. This air Compressor requires a grounded Amps or Amps line. It also must have a dedicated electrical breaker that cannot be used for any other device. The electrical outlet must be within 36 (90 cm) from the stand-alone compressor location. The stand-alone compressor must be within 25 feet of the right rear corner of the Platesetter. Escher-Grad will accommodate any national standards of power plugs, voltages and frequencies. Be sure to indicate your requirements in terms of line voltage and receptacle type on your Purchase Order. The Rip or ImageSpool Workstation will also need a wall outlet within four feet of the Platesetter. For new line installations ask the electrician to install a four-outlet socket, otherwise a power bar will be required. A 1200VA UPS or similar line regulation unit is strongly recommended to protect your Platesetter. Please note that any mechanical or electrical damage to the system that is caused by power fluctuation, surge, or failure, is not covered by either warranty or standard service agreements. Dust & dirt control is essential. Dust defects on a plate can greatly reduce productivity. As a minimum, we strongly recommend the installation of an air-filtering unit capable of removing dust particles between 5 and 50 µm in size. Seasonal variations in humidity and temperature must be taken into consideration when planning for the Platesetter installation. You may need to install an air conditioner, humidifier or dehumidifier. When choosing an air-conditioning system, consider that the Platesetter and the RIP / Imagespool workstation can generate up to 4200 BTU/hr. Please refer to the processor installation guide for information regarding the generation of additional heat by the processor. It is strongly recommended to install an instrument to measure temperature and humidity. Escher-Grad Technologies Inc. May 2002 Page 1 of 9
2 OPERATING RANGE Temperature, C/ F 19/66 20/68 21/70 22/72 23/73 24/75 25/77 Maximum RH, % Minimum RH, % OPTIMUM OPERATING RANGE Temperature, C/ F 20/68 21/70 22/72 23/73 24/75 Maximum RH, % WARNING: Exceeding the Operating Temperature Range will trigger a failsafe that will prevent the user from imaging. The failsafe will reset when the room temperature has returned to the operating range. Cobalt 8 Platesetter dimensions Platesetter 64.5" [1637 mm] Length Platesetter Width 35.75" [907 mm] Platesetter Height 40.75" [1032 mm] Figure 1. Cobalt 8 front view Figure 2. Cobalt 8 - side view Clearances Additional floor space required for operation and maintenance of the Platesetter: Top Front Sides Rear 60" [1524 mm] 48" [1220 mm] 48" [1220 mm] 12 [305 mm] Escher-Grad Technologies Inc. May 2002 Page 2 of 9
3 Cobalt 8 Packaging Table 1 shows the crated dimensions and weight of the Cobalt 8 and the EG-8274 Air Compressor. Unpacking the Platesetter and peripherals should be done under the physical supervision of an Escher-Grad Service Engineer. However, should your company have the necessary experience and skilled staff to safely unpack the equipment, please advise the Escher-Grad Customer Services Coordinator. Once the Platesetter has been removed from the palette it is the Customer s responsibility to ensure that the equipment is moved to the designated area. The Customer is also responsible for the safe storage of all packaging and crating material. If in the advent of a future move or shipment, replacement costs of the crating and/or packaging material, and shipping charges will be borne by the Customer. Damages due to unauthorized packing materials will void your warranty. Table 1 Crated Dimensions and Weight Product Length Width Height Weight Cobalt 8 68" 41" 60" 1200 lbs 1727 mm 1041 mm 1524 mm 715 kgs EG " 21.5" 33" 220 lbs Compressor 635 mm 546 mm 838 mm 100 kgs NOTE: If you don t have a loading dock and require a truck with a lift-gate, please contact your Escher- Grad Representative first. Unpacking your Cobalt 8 Platesetter You will need; A standard Philips #2 bit with reversing drill or screw driver Lift Truck capable of lifting the Cobalt8 from the palette. (See Cobalt8 dimensions bellow for lifting points) ¾ or 19mm open ended box wrench or socket with ratchet to remove the shipping bolts. Bottom view of palette Escher-Grad Technologies Inc. May 2002 Page 3 of 9
4 Processing Media Please consult the Escher-Grad Web site for the up-to-date list of approved media. Examples of approved media are: AGFA Lithostar LAP-V Mitsubishi SDP Alpha V LASTRA / WESTERN LITHOTECH LV-1 FUJI Brillia LP-NV Processor The plate processing facility must be set up prior to the Escher-Grad equipment installation. Water Outlet (if required) The water supply flow rate and pressure must meet the plate processor's minimum specifications. Water Control Panel (if required) Controls the water temperature and pressure and filters dirt particles in the water.. Drain (if required) Must be close to the plate processor to dispose of rinse water. Environmental Considerations When disposing of chemicals, you must respect local, provincial, state and federal environmental laws. Silver Recovery (if required) Consult your local plate supplier. Sink Recommended for washing processor rollers and guides during processor maintenance. Safelight Each type of plate has its own specific safelight requirements. Contact your plate distributor or visit the manufacturer s web site. It is critical for plate handling time, plate quality, and ink take up on the press that you use the plate manufacturers recommended spec only. Escher-Grad Technologies Inc. May 2002 Page 4 of 9
5 Site Preparation Guide Site configuration information (required) Plate brand to be used Plate processor to be used Safelight type to be used Is there a Plate Reader / Halftone dot meter on site? Yes Model to be used Is there a dedicated telephone line available to connect the RIP/PlateSetter modem? Yes Telephone Number: No What is the mechanism for dialup support/diagnostics? What are the typical resolutions and halftone line-screen settings in use? Please give a brief description of the type of jobs created at this site (i.e. books, catalogs, magazines, posters, maps, etc. and whether they are primarily color or monochrome) Site configuration information (optional) Proofing to be used Means of color management to be used RIP / ImageSpool Server parameters Processor speed RAM Number and size of installed SCSI disks Operating system and service pack PCI slots available Escher-Grad Technologies Inc. May 2002 Page 5 of 9
6 Physical space Electrical Check path to the room noting dimensions of all hallways, corners, and doorways Space meets minimum access requirements for service Platesetter dedicated power line has been installed. Compressor dedicated power line has been installed. Voltage and breaker size is adequate, and power outlet is installed and properly grounded. Sufficient electrical sockets are available for the Rip or ImageSpool Workstation. Distance from the power source to the equipment connection is adequate Environment Processor exhaust has been considered Typical room temperature: Typical room humidity: Humidity and Temperature control is installed and operational Humidity and Temperature is within operational limits. (Refer to page 2) Water Supply (For Processor only, if required) Available according to processor manufacturer spec Not available yet but to be completed by: Drainage (For Processor only, if required) Supplies Lighting Available according to processor manufacturer spec Not available yet but to be completed by: Not available Arranged for 1 box (50 Plates) of 31.5 x 40.5 (800 x 1030 mm) plate size to be on hand on date of installation. This is required for geometrical calibration and linearization. Type: Arranged for chemicals to be on hand on date of installation. Adequate supply of chemicals for the plate processor is available Type: Safelights installed and comply with plate manufacturers spec White light for maintenance and service available Escher-Grad Technologies Inc. May 2002 Page 6 of 9
7 Personnel Arranged for the services of a plumber when needed for servicing Arranged for the services of an electrician when needed for servicing Equipment Is a lift gate truck required? Equipment required for moving the Platesetter is available: (forklift, jigger, dollies) Working environment Flat table at least 35 (890 mm) x 45 (1143mm) available for calibration purposes Magnifier min 8-10X, available Plate handling gloves, available (if required) RIP connectivity to the network provided UPS Installed (please refer to page 4 of this document if the decision is made not to install a UPS); Telephone set available adjacently to the imaging unit RIP / ImageSpool configuration What type of connection will be used to connect the RIP to the rest of the network? 10 BaseT 100 BaseT 1000 BaseT Other - Specify: Do you need the RIP to be installed with a specific IP address on the existing network? Yes Specify: No the IP address will be set between: and Do you need the RIP to be installed with a specific Host/Machine name? Yes Specify: No the Host/Machine name will be set as: EG-<Company Name> Will the RIP be installed in a network where subnets are defined and masking ranges need to be set? Yes Specify: No Net mask will be set as: Escher-Grad Technologies Inc. May 2002 Page 7 of 9
8 What protocol/connection will be used to send files to the RIP server? Macintosh LaserWriter connection (AppleTalk) Macintosh Apple Share connection (Local) Both Macintosh LaserWriter and Apple Share connections (AppleTalk and Local) PC LaserWriter connection (Cops Talk using AppleTalk) PC AppleTalk connection (Cops Talk using Local) Both PC LaserWriter and Apple Share connections (Cops Talk using both AppleTalk and Local) PC PC/NFS or equivalent (Local) PC Windows NT Apple Share services (AppleTalk and Local) OPI server. Please specify the type of connection to the RIP. (i.e.: AppleTalk or Local, the make and version number of the OPI software in use and the hardware platform it is running on). Print Spooler without OPI. Please specify the type of connection to the RIP. (i.e. AppleTalk or Local, the make and version number of the spooler software in use and the hardware platform it's running on). PC NetBEUI protocol (Windows Networking). PC IPX/SPX protocol (NetWare) PC TCP/IP protocol Other. Please specify the type of connection to the RIP. (i.e. AppleTalk or Local, the make and version number of the software in use and the hardware platform it is running on). Which imposition software package/s are in use at this site? Please specify both product name/s and version number/s None Escher-Grad Technologies Inc. May 2002 Page 8 of 9
9 Will the RIP be imaging onto more than one device? Yes (Please specify the number and type of devices) No Will the RIP be connected to existing peripherals (i.e. hard disk/s, CD-ROM drives, tape units)? Yes (Please specify) No Please list all plate and thickness sizes that you will be using. PLEASE FAX PAGES 5-9 TO ESCHER-GRAD CUSTOMER SERVICE. FAX# (514) Please note: Any costs incurred due to delays during installation directly related to incorrect information in this Pre-Installation Checklist will be at the Customer's expense. Any costs/damages incurred due to incorrect installation and use of third party equipment (such as processors, etc.) directly affecting the general operation of an Escher-Grad PlateSetter will be at the customer's expense I hereby confirm that the above information is complete and correct. Name (please print) Title (please print) Signature Date Escher-Grad Technologies Inc. May 2002 Page 9 of 9
Pre-installation Manual
Pre-installation Manual Rinse Gum Unit 85-125-165 Pre-installation Manual Rinse Gum Unit 85-125-165 T11018 Edition BA, March 2006 This book has part no 51477 0-2 Introduction Part 0: Introduction This
More informationTA Instruments Installation Requirements for Microcalorimeter Systems
TA Instruments Installation Requirements for Microcalorimeter Systems Thank you for ordering a Microcalorimeter system from TA Instruments. To ensure that installation of that system goes as smoothly as
More informationTA Instruments Installation Requirements for Microcalorimeter Systems
TA Instruments Installation Requirements for Microcalorimeter Systems Thank you for ordering a Microcalorimeter system from TA Instruments. To ensure that installation of that system goes as smoothly as
More informationNano DSC and MCDSC. Site Preparation Guide
Nano DSC and MCDSC Site Preparation Guide Revision A Issued May 2017 Table of Contents Table of Contents... 1 Ideal Setup... 2-3 MCDSC... 2 Nano DSC... 3 System Components... 4 Instrument Measurements...
More informationICS Entrance Management Sign Installation Guide. Version 1.0
ICS Entrance Management Sign Installation Guide Version 1.0 Thank you for purchasing your new ICS Entrance Management System (EMS) from Innovative Control Systems, Inc. Installation Overview This document
More informationicore Kiosk system Installation Guide
icore Kiosk system Installation Guide The reproduction, transmission or use of this document or its contents is not permitted without express authority. Offenders will be liable for damages. All rights,
More informationUser Safety. Electrical Safety. Phaser 4500 Laser Printer
User Safety Your printer and the recommended supplies have been designed and tested to meet strict safety requirements. Attention to the following information will ensure the continued safe operation of
More informationTAM Air Isothermal Calorimeter. Site Preparation Guide
TAM Air Isothermal Calorimeter Site Preparation Guide Revision B Issued June 2017 Table of Contents Table of Contents... 1 Ideal Setup... 2 System Components... 3 Instrument Measurements... 4 Utility Requirements...
More informationCustomer Responsibilities
For Research Use Only. Not for use in diagnostic procedures. Thank you for purchasing the Agilent G5590A BenchCel Workstation. To get you started and to assure a successful and timely installation, please
More informationSite Readiness Guide. September 2015
Site Readiness Guide September 2015 Copyright This document is provided "as-is." Information and views expressed in this document, including URL and other Internet website references, may change without
More informationFOX-50 Heat Flow Meter
FOX-50 Heat Flow Meter Site Preparation Guide Revision A Issued June 2016 Page 1 Table of Contents Table of Contents... 1 Ideal Setup... 2 System Components... 3 Instrument Measurements... 4 Utility Requirements...
More informationTA Instruments Installation Requirements for Microcalorimeter Systems
TA Instruments Installation Requirements for Microcalorimeter Systems Thank you for ordering a Microcalorimeter system from TA Instruments. To ensure that installation of that system goes as smoothly as
More informationSite Readiness Guide. October 2017
Site Readiness Guide October 2017 Copyright This document is provided "as-is." Information and views expressed in this document, including URL and other Internet website references, may change without
More informationDealer Name. Dealer Contact. Phone Number. Customer Name. Installation Address. Customer Phone Number. Customer Contact for Installation
Page 1 of 5 DPX System Pre-Installation Checklist Installation will not be scheduled until this form is completed and returned to Anne Wedrogowski, via fax 914-921-2495, or Email Awedrogowski@mitsubishiimaging.com
More informationLatex 110 Printer. Site preparation guide
Latex 110 Printer Site preparation guide 2015 Hewlett-Packard Development Company, L.P. 1st edition Legal notices The information contained herein is subject to change without notice. The only warranties
More informationNOTE: All facility requirements must be met before 3D Systems Customer Support can schedule a trip to your facility to install the printer.
Facility Guidelines This section provides details relating to site selection, site preparation and readiness of the facility to accept and install the ProJet Professional Printing System. Discuss appropriate
More informationCary 50. Pre-Installation Manual
Cary 50 Pre-Installation Manual Notices Agilent Technologies, Inc. 1999, 2006 and 2011 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or
More informationBroadband Automatic Disconnect Switch. User Manual
Reset/Test Primary/ Primary Broadband Automatic Disconnect Switch User Manual Local Power Remote Pwer Local 63V Fault Secondary Select Secondary 220V Normal 990-1929 09/2004 Introduction Introduction
More informationInstallation. MGE Galaxy 3500 and Smart-UPS VT. Maintenance Bypass, Distribution and Transformer Cabinet
Installation MGE Galaxy 3500 and Smart-UPS VT Maintenance Bypass, Distribution and Transformer Cabinet American Power Conversion Legal Disclaimer The information presented in this manual is not warranted
More informationModel 7416LED
INSTALLATION INSTRUCTIONS FOR Model 7416LED www.sportablescoreboards.com 1 Table of Contents DESCRIPTION... 3 THE SCOREBOARD SYSTEM SHOULD INCLUDE THE FOLLOWING PARTS:... 3 INSTRUCTIONS FOR REPORTING SHIPPING
More informationTOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models
TOT Series Manual North American CE and UK Models CE Models UK Models North American Models Table of Content 1. Important Safety Instructions 2. Description Shipping Carton & Packing Material Placement
More informationTOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown
TOT Series Manual North American and International Models - without optional faceplate Receptacle Panel of International Models, CE model shown North American Models Table of Content 1. Important Safety
More informationMIC-3001/8. 3U/4U CompactPCI Enclosure for Rack Mounting. User Manual
MIC-3001/8 3U/4U CompactPCI Enclosure for Rack Mounting User Manual Copyright The documentation and the software included with this product are copyrighted 2004 by Advantech Co., Ltd. All rights are reserved.
More informationDiscovery SDT650. Site Preparation Guide. Revision A Issued March Page 1
Discovery SDT650 Site Preparation Guide Revision A Issued March 2017 Page 1 Table of Contents Table of Contents... 2 Ideal Setup... 3 System Components... 4 Instrument Measurements... 5 Utility Requirements...
More informationBenchmark Plus Microplate Reader User Manual. This Instrument for Laboratory Use Only Rev C
Benchmark Plus Microplate Reader User Manual This Instrument for Laboratory Use Only 4100172 Rev C 4100172 Rev C Benchmark Plus System with Incubator Catalog Number 170-6930 Benchmark Plus Reader with
More informationCustomer Responsibilities
For Research Use Only. Not for use in diagnostic procedures. Thank you for purchasing an Agilent G5573A Bravo NGS Option A. To get you started and to assure a successful and timely installation, please
More informationInstallation Job Aid for Ethernet Routing Switch 3600 Series
Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions
More informationCisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2
Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,
More informationESV3000 ETDRS Illuminated Cabinet INSTRUCTION MANUAL
ESV000 ETDRS Illuminated Cabinet INSTRUCTION MANUAL ACTUAL SIZE LETTER FOOT METER SIZE 0 0 80 24 24M 6 50 40 2 25 20 16 19 15 12 9.5 7.5 6 4.8 Developed by Lea Hyvärinen, M.D. FOR TESTING AT FEET ( METERS)
More informationOwner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series
Owner s Manual 19 Pro Series Rack Mount (RK) Faceplate Isolate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) Colours Restore. Power Conditioners Audio / Video Power Isolation
More informationLVN5200A-R2, rev. 1, Hardware Installation Guide
LVN5200A-R2 LVN5250A-R2 LVN5200A-R2, rev. 1, Hardware Installation Guide Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support
More informationdedicated KVM switch and rackmount screen technology User Manual CV-1201D DVI-D KVM Designed and manufactured by Austin Hughes
dedicated KVM switch and rackmount screen technology User Manual CV-1201D DVI-D KVM Designed and manufactured by Austin Hughes 751 Legal Information First English printing, October 2002 Information in
More informationE-Series Site Preparation Guide
E-Series Site Preparation Guide September 2017 215-11797_A0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 10 Specifications of the model 3040 40U cabinet...
More informationInstallation Job Aid for VSP 4850GTS
Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe
More informationInstallation Job Aid for VSP 4450GTX-HT- PWR+
Installation Job Aid for VSP 4450GTX-HT- PWR+ Notices Release 6.1.0.0 NN46251-305 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs
More informationMODEL 3312 LED
INSTALLATION INSTRUCTIONS FOR MODEL 3312 LED www.sportablescoreboards.com 1 Table of Contents DISCRIPTION... 3 THE SCOREBOARD SYSTEM SHOULD INCLUDE THE FOLLOWING PARTS:... 3 INSTRUCTIONS FOR REPORTING
More informationThe power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.
The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings
More informationIMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING (SAVE THESE INSTRUCTIONS): This manual contains important instructions that should be followed during installation
More informationDOT MATRIX PRINTER SP6000 SERIES
DOT MATRIX PRINTER SP6000 SERIES Hardware Manual < Approval: CEL > Trademark acknowledgments SP6000 : Star Micronics Co., Ltd. Notice All rights reserved. Reproduction of any part of this manual in any
More informationMIC-3001/8. 3U/4U CompactPCI. Enclosure for Rackmounting
MIC-3001/8 3U/4U CompactPCI Enclosure for Rackmounting Copyright Notice This document is copyrighted, 1999. All rights are reserved. The original manufacturer reserves the right to make improvements to
More informationDisplayMaker UV Curable Inkjet Printers
DisplayMaker UV Curable Inkjet Printers Site Preparation Guide for the DisplayMaker 72UVR, DisplayMaker 72UVX, and DisplayMaker 98UVX ColorSpan is a registered trademark of MacDermid ColorSpan, Inc. Other
More information2 Your printer. To get up and running with your. EPSON Stylus COLOR 850, you ll need to: Set up the printer
Copyright 1998 by Epson America, Inc. To print this image, see step 3 in your Start Here guide for step-by-step instructions. Be sure to use the EPSON Photo Quality Glossy Paper found in your free EPSON
More informationObtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx
Preface Obtaining Documentation and Submitting a Service Request, page xvii Safety s, page xvii Safety Guidelines, page xx Obtaining Documentation and Submitting a Service Request For information on obtaining
More informationiconverter 2-Module Power Chassis
iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by
More informationThermal Diffusivity Instruments DLF-2 with EM-1600
Thermal Diffusivity Instruments DLF-2 with EM-1600 Site Preparation Guide Revision A Issued February 2017 Table of Contents Table of Contents... 1 Ideal Setup... 2-3 System Components... 3 Instrument Measurements...
More informationDell MD1280 Storage Enclosure Getting Started Guide
Dell MD1280 Storage Enclosure Getting Started Guide Regulatory Model: SP-2584, E11J Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.
More informationModel: VA/230W UPS Backup System
IMPORTANT SAFETY INSTRUCTIONS (SAVE THESE INSTRUCTIONS) This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of unit.
More informationChapter 1: About the POPnetserver 2000
ABOUT THE POPNETSERVER 2000 Chapter 1: About the POPnetserver 2000 Introduction The POPnetserver is a network file server that can be used to increase network storage on LAN-based networks in minutes.
More informationTABLET DOCK USER S GUIDE
Fujitsu Stylistic ST Series Tablet PC TABLET DOCK USER S GUIDE Warning Handling the cord on this product will expose you to lead, a chemical known to the State of California to cause birth defects or other
More informationPower Supply (48Vdc, 2.5A)
Telecommunications Group Section 855-180-201 Equipment Issue 1 Fourth Printing, September 2006 8551-80 Power Supply (48Vdc, 2.5A) Compliant with UL Standard 60950, Second Edition* CONTENTS PAGE Part 1.
More informationInstallation and Operation Back-UPS BR1000G-IN / BR1500G-IN
Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Important Safety Information Read the instructions carefully to become familiar with the equipment before trying to install, operate, service
More information60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application
WWW.PHIHONG.COM 60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3bt Standard Non-Vented Case with Mounting Bracket
More informationUser Manual RKD-KVM-20 / RKDS-KVM-20. WRKD-KVM-19 / WRKDS-KVM-19 Series. Series
User Manual RKD-KVM-20 / RKDS-KVM-20 Series - 1U 20" LCD keyboard drawer - Resolution up to 1600 x 1200 - Full range KVM options WRKD-KVM-19 / WRKDS-KVM-19 Series - 1U widescreen 19" LCD keyboard drawer
More informationXBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE
XBDM 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL www.xpcc.com 2013 Xtreme Power Conversion Corporation. All rights reserved. Table of Contents IMPORTANT SAFETY INSTRUCTIONS:... 4 INTRODUCTION...
More informationDiscovery Hybrid Rheometer
Discovery Hybrid Rheometer Site Preparation Guide Revision F Issued September 2018 Table of Contents Table of Contents... 2 Ideal Setup... 3 System Components... 4 Instrument Measurements... 5 Utility
More information1. Carefully unpack the um260 s shipping carton and check the contents for damage.
um260 Installation Manual um260 Installation Chapter 4 um260 MICRO MONITOR INSTALLATION This section of the um260 Micro Monitor Installation Manual describes the requirements and procedures for installing
More informationBURSON. Burson Soloist Headphone Amplifier / Pre Amplifier. User Manual. Want free warranty extension? Please read page 6 for details I II III
Burson Soloist Headphone Amplifier / Pre Amplifier User Manual Want free warranty extension? Please read page 6 for details BURSON I II III L M H HHHISOLOI Thank You. All of us at Burson Audio would like
More informationWhat s in the Box. Table of Contents
Table of Contents 1. What s in the Box 2. Warning 2. Overview 3. Quick Start Guide 4. Rear Panel 5. Front Panel 5. DC trigger 5. Logo trim tool 6. Troubleshooting Guide 7. Warranty and Service 8. Contact
More informationPDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL
PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL 1 IMPORTANT SAFETY INSTRUCTION READ FIRST This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure-voltage
More informationIBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems
IBM United States Hardware Announcement 111-139, dated July 26, 2011 IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems Table of contents 1 Overview 3 Publications
More informationIPR-150 INSTALLATION GUIDE 150KVA Three-Phase Release 1.0
INSTALLATION GUIDE 150KVA Three-Phase Release 1.0 USER MANUAL TABLE OF CONTENTS INTRODUCTION... 4 Audience... 4 Related Documentation... 4 Support... 4 Specifications... 4 SAFETY... 6 RECEIVING... 6 DESCRIPTION...
More informationToll Free: Tel: Fax:
Toll Free: 1-888-865-6888 Tel: 510-226-8368 Fax: 510-226-8968 Email: sales@rackmountmart.com User Manual LCDK 1070 DVI-D KVM Legal Information First English printing, October 2002 Information in this document
More informationAll company and product names are or Registered Trademarks of their respective owners.
Install guide No part of this documentation may be reproduced in any form whatsoever or be stored in any data retrieval system without prior written permission of the copyright owners. This documentation
More informationJunos WebApp Secure 5.0 Hardware Guide
Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a
More informationHP StorageWorks. XP24000/XP20000 Disk Array Site Preparation Guide
HP StorageWorks XP4000/XP0000 Disk Array Site Preparation Guide Part Number: AE00-96055 Seventh edition: October 010 Legal and notice information Copyright 008, 010 Hewlett-Packard Development Company,
More informationTempco Instruction Manual
Tempco Instruction Manual 1/16 DIN Solid State Temperature Controller Relay Output Solid State Output For Heating Model Numbers: TEC-901, TEC-902, TEC-905 Temperature controls in this series are designed
More informationUser Manual Back-UPS BE650MC
User Manual Back-UPS BE650MC Inventory Back-UPS ES 650 bu075b This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with fluids, or where there is excessive
More informationMIC Advantech CompactPCI. Modular Industrial Computer. 10U high 8-slot enclosure with CT bus and rear I/O for CompactPCI backplane
MIC-3081 10U high 8-slot enclosure with CT bus and rear I/O for CompactPCI backplane Advantech CompactPCI Modular Industrial Computer Copyright Notice This document is copyrighted, 2003. All rights are
More informationKM-4800w. Installation Guide
KM-4800w Installation Guide TABLE OF CONTENTS page 1 Installation Requirements 2 2 Unpacking 3 2. 1 Unpacking 3 2. 2 Confirmation of Accessories 5 3 Leveling the Machine 7 4 Setup of the Roll Deck 9 5
More informationUniversal AC Power Source + AC Power Analyzer
User's Guide Universal AC Power Source + AC Power Analyzer Model 380820 Introduction Congratulations on your purchase of the Extech Model 380820. This Universal AC Power Source and AC Power Analyzer can
More informationOPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM
OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM Document No. 101052 Rev. 01 PAGE 2 INDEX 1 1 TECHNICAL SUMMARY... 4 1.1 BRIEF
More informationBurson Audio DA-160 Audio DAC User Manual
Burson Audio DA-160 Audio DAC User Manual www.bursonaudio.com Want free warranty extension? Please read page 7 for details. Burson Audio U1 U2 C T H L THANK YOU...3 TEAM BURSON...3 UNPACKING...4 THE ACCESSORY
More informationRADCOM s Platform Specifications. Valid from Version 7.10
Valid from Version 7.10 RADCOM Ltd., November 2006 IP Notices: 2006 RADCOM Ltd. All rights reserved. RADCOM is a trademark of RADCOM Ltd. in Israel and/or other countries. Microsoft Windows and Microsoft
More informationFAZE 800 FT PRO USER MANUAL. Version: 1.2. ROBE Lighting s.r.o. Czech Republic
FAZE 800 FT PRO USER MANUAL Version: 1.2 ROBE Lighting s.r.o. Czech Republic www.robe.cz FAZE 800 FT PRO Table of contents 1. Introduction 4 2. Cautions 4 3. Opening the package and inspecting the machine
More informationEZ Switch EZ Connect N SMCFS1601/SMCFS2401
EZ Switch EZ Connect N Draft 16/24-Port 11n Wireless Fast Ethernet USB2.0 Adapter Switch SMCFS1601/SMCFS2401 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered
More information4170 POS System Installation Guide
4170 POS System 4170 Installation Guide Thank you for selecting UTC RETAIL s innovative Model 4170 Point of Sale solution! This Installation Guide will help you efficiently install the 4170 POS. The document
More informationGEU Port Gigabit Switch
GEU-0522 5-Port Gigabit Switch Table Of Contents 1. INTRODUCTION... 3 1.1 Product Briefs... 3 1.2 Product Features... 3 1.3 Hardware Introduction... 4 2. CONNECTING THE SWITCH... 5 2.1 Package Contents...
More informationOracle Public Cloud Machine Deploying Oracle Database Exadata Cloud at Customer. Release
Oracle Public Cloud Machine Deploying Oracle Database Exadata Cloud at Customer Release 17.2.3 E89135-03 December 2017 Oracle Public Cloud Machine Deploying Oracle Database Exadata Cloud at Customer, Release
More informationE-Tool Mobile Manager 6 Drawer Rugged Managed (Rev. 0)
E-Tool Mobile Manager 6 Drawer Rugged Managed (Rev. 0) Part # 563-0113-F04-00 Part # 563-0113-F31-00 Publication # 095-2021-000-00 Rev. B www.tracewell.com/platforms/ietm/ietmlanding.php 1 614-846-6175-800-848-4525
More informationIBM Systems. Quick start guide for IBM System p5 505 ( )
IBM Systems Quick start guide for IBM System p5 505 (9115-505) 1 Before you begin This Quick start guide contains an abbreviated set of setup instructions designed to help you quickly unpack and set up
More information16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch
12 Omnitron Systems Technology, Inc. Omnitron Systems Technology, Inc. 1 FlexSwitch TM 600X 16/24 Port /0 -Sensing Dual Speed Ethernet Switch User s ual 27 Mauchly #201, Irvine, CA 92618 (949) 250-65 Fax:
More informationUser s Manual (Model A) isappos 9/12 Stand
User s Manual (Model A) isappos 9/12 Stand Section 1 Overview The Jacket (unit: mm) Package Contents Aluminum base plate Aluminum Stand body Jacket for ipad 1 x Micro-USB cable (For charging and data syncing)
More informationSECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS
SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS CONTENTS PAGE 1. GENERAL... 5-1 1.1. Introduction... 5-1 1.2. Equipment Layout Requirements... 5-1 2. EQUIPMENT FRAMES... 5-2 2.1. Introduction...
More informationInstalling the Cisco MDS 9020 Fabric Switch
CHAPTER 2 This chapter describes how to install the Cisco MDS 9020 Fabric Switch and its components, and it includes the following information: Pre-Installation, page 2-2 Installing the Switch in a Cabinet
More informationPS8 - II. Professional Power Sequencer. User s Manual
PS8 - II Professional Power Sequencer User s Manual IMPORTANT SAFETY INSTRUCTIONS READ FIRST This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure.
More informationBEETLE /Fusion Compact. Installation Guide
BEETLE /Fusion Compact Installation Guide The reproduction, transmission or use of this document or its contents is not permitted without express authority. Offenders will be liable for damages. All rights,
More informationFacility Requirements Guide. ProJet X60 Series. INCLUDES: ProJet 160 ProJet 260C ProJet 360 ProJet 460Plus ProJet 660Pro ProJet 860Pro
Facility Requirements Guide ProJet X60 Series INCLUDES: ProJet 160 ProJet 260C ProJet 360 ProJet 460Plus ProJet 660Pro ProJet 860Pro 1 Description: This procedure serves as a checklist to ensure that all
More informationExpectation Setting Document for Splash PCI E320 Digital Front End for DocuColor 5750
Customer Support The erox Customer Support Centers are available to you 24 hours a day, 7 days a week to provide general information, answer questions and take service calls. You can reach the Customer
More informationPrinted on recycled paper with at least 10% post-consumer content. Setup Guide
Printed on recycled paper with at least 10% post-consumer content Setup Guide All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form
More informationLine Interactive 1000VA/1400VA/2000VA Uninterruptible Power System
USER MANUAL Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System 614-06762-00 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for Line Interactive
More informationUser s Manual. LumiVision series. A Designer s X-ray film illuminator. Walnut, CA U.S.A. By LCD TV Technology
User s Manual A Designer s X-ray film illuminator By LCD TV Technology series Point A Technologies, Inc. Walnut, CA U.S.A. FCC RF INTERFERENCE STATEMENT NOTE: This equipment has been tested and found to
More informationSpecifications for Modular Sound Shadow Sound Masking Sound Management Group, LLC.
Specifications for Modular Sound Shadow Sound Masking Sound Management Group, LLC. 1.01 General Requirements This section details general requirements for plenum sound masking installations. 1.1 Contract
More informationdedicated KVM switch and rackmount screen technology User Manual CV-801 PS/2 DB-15 KVM Designed and manufactured by Austin Hughes
dedicated KVM switch and rackmount screen technology User Manual PS/2 DB-15 KVM Designed and manufactured by Austin Hughes 751 Legal Information First English printing, October 2002 Information in this
More informationStaff Workstation Model 795
Staff Workstation Model 795 Site Planning Guide 3M Library Systems 3M Center, Building 225-4N-14 St. Paul, Minnesota 55144-1000 www.3m.com/library Copyright 2000-2001, 2004 3M IPC. All rights reserved.
More informationModels 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide
Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide Safety precautions Observe the following safety precautions before using this product and any associated instrumentation.
More informationHP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions
HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W
More informationProtect It! 7-Outlet Surge Protector, 6-ft. Cord, 1080 Joules, Fax/Modem Protection, RJ11
Protect It! 7-Outlet Surge Protector, 6-ft. Cord, 1080 Joules, Fax/Modem Protection, RJ11 MODEL NUMBER: SUPER6TEL Highlights 7 outlets / 6-ft. cord 1080 joule rating Modem/fax surge protection $50,000
More informationdedicated KVM switch and rackmount screen technology User Manual IP-S101 Combo KVM Extender Designed and manufactured by Austin Hughes
dedicated KVM switch and rackmount screen technology User Manual IP-S101 Combo KVM Extender Designed and manufactured by Austin Hughes 751 Legal Information First English printing, October 2002 Information
More informationPOWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 120 Volt
POWER AVAILABILITY 2U POD USER MANUAL Power Output Distribution 120 Volt TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS.......................................... 1 GLOSSARY OF SYMBOLS..................................................
More informationUSER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power
Critical Power USER MANUAL Uninterruptible Power Supply Line-interactive VCL Series UPS 400 600 800 1000 1500 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland
More information