SED2 Variable Frequency Drives Startup, Operation, and Maintenance Manual

Size: px
Start display at page:

Download "SED2 Variable Frequency Drives Startup, Operation, and Maintenance Manual"

Transcription

1 SED2 Variable Frequency Drives Startup, Operation, and Maintenance Manual Item Number , Rev. 012

2

3 SED2 Variable Frequency Drives Startup, Operation, and Maintenance Manual

4

5 NOTICE The information contained within this document is subject to change without notice and should not be construed as a commitment by Siemens Building Technologies, Inc. Siemens Building Technologies, Inc. assumes no responsibility for any errors that may appear in this document. All software described in this document is furnished under a license and may be used or copied only in accordance with the terms of such license. SERVICE STATEMENT Control devices are combined to make a system. Each control device is mechanical in nature and all mechanical components must be regularly serviced to optimize their operation. All Siemens Building Technologies, Inc. branch offices and authorized distributors offer technical support programs that will ensure your continuous, trouble-free system performance. For further information, contact your nearest Siemens Building Technologies, Inc. representative. CREDITS Product or company names mentioned herein may be the trademarks of their respective owners. Copyright 2003 by Siemens Building Technologies, Inc. TO THE READER Your feedback is important to us. If you have comments about this manual, please submit them to technical.editor@siemens.com. Printed in U.S.A.

6

7 Table of Contents Table of Contents How To Use This Manual... 1 Manual Organization... 1 Manual Notations... 2 Where To Send Comments... 2 Reference Documents... 2 Safety Instructions... 3 General... 3 Environmental Compatibility and Disposal... 4 Mechanical Installation... 5 Product Numbers... 5 Frame Sizes... 6 Interpreting Serial Numbers and Date Codes... 7 Output Ratings... 8 Accessories Environmental Conditions Dimensions and Mounting for IP20 SED2s Overall Dimensions and Mounting Specifications Mounting Dimensions Mounting Instructions Gland Plate Installation and Conduit Connections Dimensions and Mounting for NEMA Type 1 SED2s Overall Dimensions and Mounting Specifications Mounting Dimensions Mounting Instructions Dimensions and Mounting for IP54, NEMA Type 12 SED2s Overall Dimensions and Mounting Specifications Mounting Dimensions Mounting Instructions Electrical Installation Extended Storage: Conditioning of Capacitors Input Power and Motor Connections Operation in Ungrounded Systems Siemens Building Technologies, Inc. i

8 SED2 VFD Startup, Operation, and Maintenance Manual Ungrounded Systems and Y Capacitor Access to Connection Terminals Motor Frequency and Unit of Measurement DIP Switches Input Power and Motor Terminal Layout Tightening Torque for Input Power and Motor Connections Cable Cross-Sections for Input Power and Motor Cables Input Power Connection Motor Cable Length Motor Connection (Wye "Y"/Star or Delta Configuration) Direction of Motor Rotation Motor Overload Protection Connection of Multiple Motors Analog Input DIP Switches Control Terminal Connections Control Terminal Layout Analog and Digital I/O Control Terminal Connections Parameters Overview Parameter Structure Parameter Indexes SED2 Operator Panels Overview Basic Operator Panel (BOP) Advanced Operator Panel (AOP) BOP Display and Pushbuttons Commissioning Motor Nameplate Data for Parameter Settings Prerequisites to Startup Procedure SED2 (stand-alone) Startup Procedure Quick Commissioning Procedure ii Siemens Building Technologies, Inc.

9 Table of Contents Additional Parameter Settings Flying Start Automatic Restart Vdc Controller Pulse Frequency Reset to Factory Defaults Network Communications Changing Individual Parameter Digits Maintenance Prerequisites General Inspection and Cleaning Muffin Fan Inspection and Cleaning Re-energize Unit DC Bus Integrity Test Contactors and Switches Motor Bearing Wear Troubleshooting Reading Faults Resetting Faults Troubleshooting the Operator Panel Troubleshooting Using the Operator Panel Fault Codes Warning Messages Replacement Parts Repair Technical Specifications Appendix A: Parameters, Defaults, and Settings Appendix B: SED2 Point Maps Glossary Siemens Building Technologies, Inc. iii

10

11 How to Use This Manual How To Use This Manual This manual is written for users of Siemens Building Technologies, Inc. SED2 Variable Frequency Drives (VFDs). It contains information to install, commission, and set parameters for SED2s in order to provide effective and trouble-free operation. Manual Organization This manual contains the following sections: Section How to Use this Manual Safety Instructions Mechanical Installation Electrical Installation Parameters SED2 Operator Panels Commissioning Maintenance Troubleshooting Replacement Parts Repairs Appendix A: Parameters, Defaults, and Settings Appendix B: SED2 Point Maps Glossary Description Describes the organization of this manual, its notations, and lists reference documents. Presents general safety regulations, guidelines, and recommendations. Provides information for mounting and installing a SED2. Provides information for installing and terminating SED2 wiring. Provides an overview about SED2 parameters. Provides an overview about the SED2 Basic Operator Panel and its pushbuttons Describes how to commission and start a SED2 for operation. Provides preventive maintenance information. Lists SED2 fault codes, and warning messages. Provides a list of SED2 replacement parts. Provides repair information. Provides a table of SED2 parameters with the number, title, and user access level. Provides a SED2 P1 point map for APOGEE Automation Systems and a SED2 N2 point map for Johnson Controls, Inc. systems. Defines terms related to the SED2. Siemens Building Technologies, Inc. 1

12 SED2 VFD Startup, Operation, and Maintenance Manual Manual Notations Notation Symbol Meaning DANGER: WARNING: CAUTION: Indicates that personal injury, or loss of life may occur if you do not perform a procedure as specified. Indicates that personal injury, or equipment damage may occur if you do not perform a procedure as specified. Indicates that equipment damage, or loss of data may occur if you do not perform a procedure as specified. Where To Send Comments Your feedback is important to us. If you have comments about this manual, please submit them to technical.editor@siemens.com. Reference Documents SED2s control the speed of fan and pump motors. SED2s can also be programmed to manage many other motor functions and limits set by parameters, which are programmed using the SED2 keypad. See the SED2 VFD Parameter Reference Guide ( ) for more details and a complete listing of the SED2 parameters. The following SED2 documentation is available from your local Siemens Building Technologies, Inc. representative: SED2 VFD AOP Operating Instructions ( ), operating instructions and procedures for the SED2 Advanced Operator Panel. SED2 VFD Conventional Bypass Operating Instructions ( ), start-up and operation of the SED2 Conventional Bypass Option. SED2 VFD Electronic Bypass Operating Instructions ( ), start-up, application, and operation of the SED2 Electronic Bypass Option. SED2 VFD LON Interface Option Operating Instructions ( ), startup and operation of the SED2 LON Interface Option. 2 Siemens Building Technologies, Inc.

13 Safety Instructions Safety Instructions General The following general guidelines are provided for your safety, to prevent damage, and to extend the service life of the SED2 product and any connected equipment. Read this information carefully. Specific Warnings, Cautions, and Notes are provided in the relevant sections of this manual. WARNING: The SED2 uses hazardous voltages and controls potentially dangerous rotating mechanical parts. Noncompliance with warnings, or failure to follow the instructions contained in this manual, can result in loss of life, severe personal injury, or serious damage to property/equipment. Only authorized personnel should work on this equipment, and only after becoming familiar with all local regulations and ordinances, safety notices, and procedures in this manual. Successful and safe operation of this equipment depends upon its proper handling, installation, operation, and maintenance. Before doing any installation and commissioning procedures, you must read all safety instructions and warnings, including all warning labels attached to the equipment. Ensure that the warning labels are legible and replace missing or damaged labels. Observe the regulations of safety codes whenever working with live equipment and high-voltage installations. Also, use suitable tools and protective equipment. Prevent any unauthorized person from accessing or approaching this equipment. NOTE: Keep this manual near the equipment and available to all users. Siemens Building Technologies, Inc. 3

14 SED2 VFD Startup, Operation, and Maintenance Manual Environmental Compatibility and Disposal The SED2s are developed and manufactured using materials and processes that take full account of environmental issues and which comply with environmental standards. For disposal at the end of the SED2 service life or in the event of its replacement, note the following: For disposal purposes, this product is defined as waste derived from electrical and electronic equipment ( electronic waste ) and must not be disposed of as household waste. This applies particularly to the PCB assembly. Always use the most environmentally compatible method of disposal, in line with the latest developments in environmental protection, recycling, and waste management. Observe all local legislation and applicable laws. Always aim for maximum re-use of the basic materials, and minimum environmental stress. Observe any notes about materials and disposal that may be attached to individual components. Use local depots and waste management companies, or see your supplier or manufacturer to return used products or to obtain further information on environmental compatibility and waste disposal. Special handling of components such as electrolytic capacitors and LCD panels may in some cases be compulsory by law or environmentally desirable. The SED2 is delivered in re-usable packaging. Please retain this packaging for later use or in case you need to return the product. 4 Siemens Building Technologies, Inc.

15 Mechanical Installation Mechanical Installation Product Numbers The following chart shows SED2 product numbers: Your Product Number: S E D 2 - Example Product Number: S E D / 2 2 X Model: SED2- kw: 0.37, 0.55, 0.75, 1.1, 1.5, 2.2, (use 2 to 4 spaces 3, 4, 5.5, 7.5, 11, 15, 18.5, 22, 30, 37, 45, 55, 75, 90 plus a divider "/") Voltage: 2 = 200 to = 380 to = 500 to 600 NEMA: 2 = (IP20) 1 = NEMA Type 1 5 = NEMA Type 12 (IP54) * Other: X = Other (leave blank) * Available with Voltage Codes 3 and 4. Example shown: SED2-0.75/22X = SED2 only, 0.75 kw (1 hp), 200V to 240V, open type IP20. Siemens Building Technologies, Inc. 5

16 SED2 VFD Startup, Operation, and Maintenance Manual Frame Sizes The following chart shows SED2 IP20 and NEMA Type 1 (drive only) frame sizes and power ranges. HP kw V A B C D E F 480V A B C D E F 575V C The following chart shows SED2 IP54, NEMA Type 12 (drive only) frame sizes and power ranges. HP kw V 575V B C C D E F 6 Siemens Building Technologies, Inc.

17 Mechanical Installation Interpreting Serial Numbers and Date Codes Each SED2 has a manufacturing/serial number. The date of manufacture, or the date code, is part of the serial number. The following examples show how to interpret the date code and serial code. Example 1: A SED2 manufactured April 21, 2000 with a serial number. X A M Indicates manufacturing location Year: Month: M = 00 N = 01 O = 02 P = 03 Q = 04 Jan = 1, Feb = 2,... Sept = 9, Oct = O, Nov = N, Dec = D Day: 01 through 31 A separator to facilitate reading of the serial number. Six-digit serial number in the range of 1 through Example 2: A SED2 manufactured July 24, 2001 with a serial number. T - N Indicates manufacturing location Year: Month: M = 00 N = 01 O = 02 P = 03 Q = 04 Jan = 1, Feb = 2,... Sept = 9, Oct = O, Nov = N, Dec = D Day: 01 through 31 Product number Five-digit serial number in the range of 1 through Siemens Building Technologies, Inc. 7

18 SED2 VFD Startup, Operation, and Maintenance Manual Output Ratings Table 1 shows SED2 product numbers and the associated output ratings. Voltage (±10%) Table 1. SED2 Product Numbers and Output Ratings. Product Number IP20 NEMA Type 1 IP54, NEMA Type 12 Output Rating HP kw Output Current Max. (amps) Frame Size SED2-0.37/22X SED2-0.37/21X A SED2-0.55/22X SED2-0.55/21X A SED2-0.75/22X SED2-0.75/21X A SED2-1.1/22X SED2-1.1/21X B SED2-1.5/22X SED2-1.5/21X B SED2-2.2/22X SED2-2/21X B SED2-3/22X SED2-3/21X C SED2-4/22X SED2-4/21X C SED2-5.5/22X SED2-5.5/21X C SED2-7.5/22X SED2-7.5/21X C SED2-11/22X SED2-11/21X D SED2-15/22X SED2-15/21X D SED2-18.5/22X SED2-18.5/21X D SED2-22/22X SED2-22/21X E SED2-30/22X SED2-30/21X E SED2-37/22X SED2-37/21X F SED2-45/22X SED2-45/21X F SED2-0.37/32X SED2-0.37/31X A SED2-0.55/32X SED2-0.55/31X A SED2-0.75/32X SED2-0.75/31X A SED2-1.1/32X SED2-1.1/31X SED2-1.1/35X A * SED2-1.5/32X SED2-5/31X SED2-1.5/35X A * SED2-2.2/32X SED2.2/31X SED2-2/35X B SED2-3/32X SED2-3/31X SED2-3/35X B SED2-4/32X SED2-4/31X SED2-4/35X B SED2-5.5/32X SED2-5.5/31X SED2-5.5/35X C SED2-7.5/32X SED2-7.5/31X SED2-7/5/35X C SED2-11/32X SED2-11/31X SED2-11/35X C SED2-15/32X SED2-15/31X SED2-15/35X C SED2-18.5/32X SED2-18.5/31X SED2-18.5/35X D SED2-22/32X SED2-22/31X SED2-22/35X D SED2-30/32X SED2-30/31X SED2-30/35X D SED2-37/32X SED2-37/31X SED2-37/35X E SED2-45/32X SED2-45/31X SED2-45/35X E SED2-55/32X SED2-55/31X SED2-55/35X F SED2-75/32X SED2-75/31X SED2-75/35X F SED X SED2-90/31X SED2-90/35X F * IP54, NEMA Type 12 drives start at Frame Size B. 208V to 240V (3-Phase) 380V to 480V (3-Phase) 8 Siemens Building Technologies, Inc.

19 Mechanical Installation Voltage (±10%) 500V to 600V (3-Phase) Table 1. SED2 Product Numbers and Output Ratings. (Continued) Product Number IP20 NEMA Type 1 IP54, NEMA Type 12 Output Rating HP kw Output Current Max. (amps) Frame Size SED2-0.75/42X SED2-0.75/41X C SED2-1.1/42X SED2-1.1/41X SED2-1.1/45X C SED2-1.5/42X SED2-1.5/41X SED2-1.5/45X C SED2-2.2/42X SED2-2.2/41X SED2-2.2/45X C SED2-3/42X SED2-3/41X SED2-3/45X C SED2-4/42X SED2-4/41X SED2-4/45X C SED2-5.5/42X SED2-5.5/41X SED2-5.5/45X C SED2-7.5/42X SED2-7.5/41X SED2-7.5/45X C SED2-11/42X SED2-11/41X SED2-11/45X C SED2-15/42X SED2-15/41X SED2-15/45X C SED2-18.5/42X SED2-18.5/41X SED2-18.5/45X D SED2-22/42X SED2-22/41X SED2-22/45X D SED2-30/42X SED2-30/41X SED2-30/45X D SED2-37/42X SED2-37/41X SED2-37/45X E SED2-45/42X SED2-45/41X SED2-45/45X E SED2-55/42X SED2-55/41X SED2-55/45X F SED2-75/42X SED2-75/41X SED2-75/45X F SED2-90/42X SED2-90/41X SED2-90/45X F Siemens Building Technologies, Inc. 9

20 SED2 VFD Startup, Operation, and Maintenance Manual Accessories SED 2 accessories include the following: Gland Plates SED2-GL-A, Gland Plate, Frame A (included with NEMA Type 1) SED2-GL-B, Gland Plate, Frame B (included with NEMA Type 1) SED2-GL-C, Gland Plate, Frame C (included with NEMA Type 1) BOP/AOP Door Mounting Kits SED2-Door-Kit1, BOP/AOP Single Inverter Door Mounting Kit SED2-Door-Kit2, AOP Multi-Inverter Door Mounting Kit Protection Shields (included with NEMA Type 1) SED2-PS-A, Protection Shield, Frame A SED2-PS-B, Protection Shield, Frame B SED2-PS-C, Protection Shield, Frame C SED2-PS-DE, Protection Shield, Frame D, E Operator Panel SED2-BOP1, Basic Operator Panel (included with all SED2s) SED2-AOP1, Advanced Operator Panel LON Interface Option SED2-LONI/F Modbus Interface Cable SED2-MODBUS1, Converts SED2 USS bus to Modbus RTU 10 Siemens Building Technologies, Inc.

21 Mechanical Installation Environmental Conditions Install the SED2 in a heated, indoor-controlled environment that is free of moisture and conductive contaminants, such as condensation and dust. The air entering the unit for ventilation or cooling must be clean and free of corrosive materials. If installed in a confined space, remove the heat from the area by ventilation or by air conditioning equipment. The ambient temperature must be between 14 F and 104 F ( 10 C and 40 C) and the relative humidity must be 0% to 95% non-condensing. Do not mount unit in direct sunlight. Storage Temperature: Maximum temperature: +158 F (+70 C) * Minimum temperature: 40 F ( 40 C) Operating Temperature: Maximum temperature: +104 F (+40 C) * Minimum temperature: +14 F ( 10 C) * Be aware of the potential increase in temperature inside a control cabinet (de-rating is required; contact the factory). Humidity: Maximum 95% rh (non-condensing) Altitude: The SED2 can be installed at altitudes up to 3280 ft (1000 m) above sea level with no reduction in output current rating (contact the factory). NOTE: If installing the SED2 at an altitude higher than 3280 ft (1000 m) above sea level, de-rating is required. Location: Do not install the SED2 in an area that is exposed to repeated shock or vibration, water hazards, or atmospheric pollutants such as dust and corrosive gases. EMI and RFI: Do not install the SED2 near powerful sources of electromagnetic interference (EMI) and radio frequency interference (RFI) without a suitable filter. Siemens Building Technologies, Inc. 11

22 SED2 VFD Startup, Operation, and Maintenance Manual Dimensions and Mounting for IP20 SED2s Overall Dimensions and Mounting Specifications Table 2. Overall Dimensions of IP20 SED2 in Inches (Millimeters). Frame Size Height Width Depth Mounting Specification Tightening Torque lb-in (Nm) Weight lb (kg) A 6.8 (173) 2.9 (73) 5.9 (149) 2 x M4 Bolts, Nuts, and Washers, or Connecting to DIN rail 22 (2.5) 2.9 (1.3) B 8.0 (202) 5.9 (149) 6.8 (172) 4 x M4 Bolts, Nuts, and Washers 22 (2.5) 7.5 (3.4) C 9.6 (245) 7.3 (185) 7.7 (195) 4 x M5 Bolts, Nuts, and Washers 26 (3.0) 12.1 (5.5) D 20.5 (520) 10.8 (275) 9.6 (245) 4 x M8 Bolts, Nuts, and Washers 115 (13) 35.3 (16) E 25.6 (650) 10.8 (275) 9.6 (245) 4 x M8 Bolts, Nuts, and Washers 115 (13) 44.1 (20) F 33.5 (850) 13.8 (350) 12.6 (320) 4 x M8 Bolts, Nuts, and Washers 221 (25) 116 (53) 12 Siemens Building Technologies, Inc.

23 Mechanical Installation Mounting Dimensions Frame Size A 0.22 (5.5) 6.3 (160) Frame Size B Frame Size C 0.19 (4.8) 6.9 (174) 0.22 (5.5) 8.0 (204) 0.17 (4.5) 5.4 (138) 6.9 (174) Frame Size D Frame Size E 0.68 (17.5) Frame Size F 0.59 (15) 0.68 (17.5) 19.1 (486) 24.3 (616) 31.9 (810) VFD0012R1 9.3 (235) 9.3 (235) 11.8 (300) Figure 1. Mounting Dimensions of IP20 SED2 in Inches (Millimeters). Mounting Instructions The IP20 SED2 can mount side-by-side without space in between units. There must be a minimum clearance at the top and bottom for ventilation and equipment access. SIEMENS V min. SIEMENS Frame Size V min Minimum Clearance in Inches (Millimeters) A, B, C 4 (100) D, E 11-3/4 (300) F 13-3/4 (350) SED2 SED2 VFD0143R1 V min. Mounting Clearance Note: If fitted with a protective shield, allow 12-inches (305 mm) of space between each SED2 to allow for sufficient heat dissipation. Siemens Building Technologies, Inc. 13

24 SED2 VFD Startup, Operation, and Maintenance Manual Gland Plate Installation and Conduit Connections CAUTION: Bonding between conduit connections is not automatic and must be provided as part of the installation. Each bonding conductor must be equal or greater in crosssection to the power supply cable. Installation: Ground Conduit Connections:.90 (22.8) Ground VFD0002R1 Figure 2. Gland Plate Installation and Conduit Connection Diameters for Frame Size A. 14 Siemens Building Technologies, Inc.

25 Mechanical Installation Installation: Conduit Connections: Ground Frame Size B Frame Size C VFD0003R1.90 (22.8).74 (18.8).90 (22.8) 1.10 (28).74 (18.8) Figure 3. Gland Plate Installation and Conduit Connection Diameters for Frame Size B and C (28) Siemens Building Technologies, Inc. 15

26 ON SED2 VFD Startup, Operation, and Maintenance Manual PE 1.77 (45.0) 1.77 (45.0) 1.77 (45.0) VFD0062R (28.4).90 (22.8) Figure 4. Conduit Connection Diameters for Frame Size D and E in Inches (Millimeters). 4.4 (112) 1.8 (46) 13.5 (343) 6.8 (173) 1.8 (46).3 (58) o 0.25 (6) 1.4 o (36) 9.0 (229) o 6.1 (155) o 3.5 (89).35 (9) VFD0091R1 1.5 (38) 1.0 (25) 14.0 (356) Figure 5. Conduit Connection Diameters (Bottom View) for Frame Size F in Inches (Millimeters). 16 Siemens Building Technologies, Inc.

27 Mechanical Installation Dimensions and Mounting for NEMA Type 1 SED2s Overall Dimensions and Mounting Specifications Table 3. Overall Dimensions of NEMA Type 1 SED2 Assembled with a Protective Shield and a Gland Plate. Dimensions in Inches (Millimeters). Frame Size Height Width Depth Mounting Specification Tightening Torque lb-in (Nm) Weight lb (kg) A 9.1 (231) 2.9 (73) 5.9 (149) 2 x M4 Bolts, Nuts, and Washers, or Connecting to DIN rail 22 (2.5) 3.2 (1.5) B 11.8 (300) 5.9 (149) 6.8 (172) 4 x M4 Bolts, Nuts, and Washers 22 (2.5) 8.3 (3.8) C 13.8 (351) 7.3 (185) 7.7 (195) 4 x M5 Bolts, Nuts, and Washers 26 (3.0) 13.6 (6.2) D 24.6 (625) 10.8 (275) 9.6 (245) 4 x M8 Bolts, Nuts, and Washers 115 (13) 37.5 (17.1) E 29.7 (754) 10.8 (275) 9.6 (245) 4 x M8 Bolts, Nuts, and Washers 115 (13) 46.4 (21.1) F 54.5 (1384) 16.0 (406) 14.0 (356) 4 x M8 Bolts, Nuts, and Washers 221 (25) 200 (91) Siemens Building Technologies, Inc. 17

28 SED2 VFD Startup, Operation, and Maintenance Manual Mounting Dimensions Frame Size A 0.22 (5.5) 6.3 (160) Frame Size B 0.19 (4.8) 6.9 (174) Frame Size C 0.22 (5.5) 8.0 (204) 0.17 (4.5) 5.4 (138) 6.9 (174) Frame Size D 0.68 (17.5) 19.1 (486) Frame Size E 0.68 (17.5) 24.3 (616) Frame Size F 0.59 (15) 51 (1295) VFD0092R2 9.3 (235) 9.3 (235) 15 (381) Figure 6. Mounting Dimensions of NEMA Type 1 SED2 in Inches (Millimeters). Mounting Instructions The NEMA Type 1 SED2 must have a minimum clearance at the top and bottom for ventilation and equipment access. In addition, allow 12-inches (305 mm) of space between each SED2 to allow for sufficient heat dissipation. V min. SIEMENS 12 Inches (305 mm) V min. SIEMENS Frame Size V min Minimum Clearance in Inches (Millimeters) A, B, C 4 (100) D, E 11-3/4 (300) F 13-3/4 (350) SED2 SED2 VFD0143R1 V min. V min. 18 Siemens Building Technologies, Inc.

29 Mechanical Installation Dimensions and Mounting for IP54, NEMA Type 12 SED2s Overall Dimensions and Mounting Specifications Table 4. Overall Dimensions and Mounting Clearances for IP54, NEMA Type 12 SED2. Dimensions in Inches (Millimeters). Frame Size Overall Dimensions Mounting Clearance Height Width Depth Top Bottom Sides Mounting Specification Tightening Torque lb-in (Nm) Weight lb (kg) B 15.2 (385) 10.6 (270) 10.6 (268) 5.9 (150) 5.9 (150) 3.9 (100) 4 x M6 Bolts, Nuts, and Washers 44 (5) 22 (10) C 23.9 (606) 13.8 (350) 11.2 (284) 5.9 (150) 5.9 (150) 3.9 (100) 4 x M6 Bolts, Nuts, and Washers 44 (5) 42 (19) D 27.0 (685) 14.2 (360) 13.9 (353) 7.9 (200) 7.9 (200) 5.9 (150) 4 x M8 Bolts, Nuts, and Washers 115 (13) 77 (35) E 34.8 (885) 14.2 (360) 17.8 (453) 7.9 (200) 7.9 (200) 5.9 (150) 4 x M8 Bolts, Nuts, and Washers 115 (13) 105 (48) F 45.3 (1150) 17.7 (450) 18.6 (473) 11.8 (300) 9.8 (250) 5.9 (150) 4 x M8 Bolts, Nuts, and Washers 177 (20) 178 (81) Siemens Building Technologies, Inc. 19

30 SED2 VFD Startup, Operation, and Maintenance Manual Mounting Dimensions Frame Size B 0.19 (4.8) 13.5 (343) Frame Size C 0.22 (5.5) 22.2 (564) 9.1 (230) 12.3 (313) Frame Size F Frame Size E 0.59 (15) Frame Size D 0.68 (17.5) 0.68 (17.5) 25.5 (647) 33.5 (847) 43.8 (1112) VFD0013R (310) 12.2 (310) 15.7 (400) Figure 7. Mounting Dimensions of IP54, NEMA Type 12 SED2 in Inches (Millimeters). 20 Siemens Building Technologies, Inc.

31 Mechanical Installation Mounting Instructions There must be a clearance of at least 5-7/8 inches (150 mm) in all directions. A good bonding between the SED2 and the metal backplate is necessary to ensure good grounding and low RFI (radio frequency interference). If necessary, remove some backplate paint and/or use toothed washers to ensure safety and EMC (electro-magnetic compatibility). Earth braid screened armored cable provides the best bond. V min. SIEMENS SIEMENS S min. S min. S min. SED2 SED2 VFD0144R1 V min. Frame Size S min Minimum Clearance in Inches (Millimeters) V min Minimum Clearance in Inches (Millimeters) B, C 5-7/8 (150) 5-7/8 (150) D, E 5-7/8 (150) 11-3/4 (300) F 5-7/8 (150) 13-3/4 (350) NOTE: Install the SED2 vertically for optimum cooling. Do not obstruct the vents on the SED2. Additional ventilation may be required if the SED2 is mounted horizontally. Siemens Building Technologies, Inc. 21

32 SED2 VFD Startup, Operation, and Maintenance Manual Electrical Installation DANGER: To ensure safe operation of the SED2, authorized persons must install and commission it in full compliance with the warnings, cautions, and notes in this manual. Authorized persons must also follow general and regional installation and safety regulations regarding working with high voltages as well as relevant regulations for the correct use of tools and protective equipment. The SED2 must be grounded (per IEC 536, Class 1, NEC and other relevant industry standards). Extremely hazardous conditions may result if the SED2 is not correctly grounded. NOTE: IP20 and NEMA Type 1 SED2s can operate in ungrounded systems if the Y capacitor is disconnected or removed. IP54, NEMA Type 12 SED2s cannot operate in ungrounded systems. See the Operation in Ungrounded Systems section for more details. The SED2 is suitable for use in a circuit capable of delivering not more than 10,000 symmetrical amperes, for a maximum voltage of 240/480/575V when protected by a time delay Type J, H, or K fuse or circuit breaker. Always wait 5 minutes after disconnecting the SED2 from the power source before performing any work. The DC link capacitors of all SED2s remain charged with dangerous voltages for 5 minutes after all power sources have been disconnected. When working on IP20 units, note that live parts are exposed. Do not touch these parts. In cases where a fault in the input or output power wiring could cause significant equipment damage or severe physical injury (such as potentially dangerous short circuits), use additional external precautions to ensure safe operation (such as independent limit switches and mechanical interlocks). 22 Siemens Building Technologies, Inc.

33 Electrical Installation Extended Storage: Conditioning of Capacitors After an extended period of storage, recharge the capacitors in the SED2. Calculate the storage time from the date of manufacture or the date code, and not from the date of delivery. (See the Interpretation of Serial Numbers and Date Codes section for more details.) The recharge procedure varies according to the storage period as follows: Period of Storage Required Action Total Preparation Time 1 year or less Recharging not required. No preparation 1 to 2 years Before issuing the run command, connect the SED2 to input power for one hour. 2 to 3 years Use a variable AC power source as follows: Apply 25% of the input voltage for 30 minutes. Increase the voltage to 50% for an additional 30 minutes. Increase the voltage to 75% for an additional 30 minutes. Increase the voltage to 100% for an additional 30 minutes. The SED2 is then ready for operation. 1 hour 2 hours 3 or more years Use a variable AC power source as follows: Apply 25% of the input voltage for 2 hours. Increase the voltage to 50% for an additional 2 hours. Increase the voltage to 75% for an additional 2 hours. Increase the voltage to 100% for an additional 2 hours. The SED2 is then ready for operation. CAUTION: 8 hours After an extended period of storage, if capacitors are not properly recharged, catastrophic damage to the drive can result. Siemens Building Technologies, Inc. 23

34 SED2 VFD Startup, Operation, and Maintenance Manual Input Power and Motor Connections DANGER: Make certain that the motor rated full load amps (FLA) does NOT exceed the rated output current of the SED2 controlling it. When multiple motors are simultaneously operated by the SED2, the sum of all motor rated FLA values must be less than or equal to the SED2 controlling them. Never switch on the SED2 with it open. Always isolate the input power cables before connecting them to the SED2. Always use insulated tools when working on input power and motor terminals. Ensure that terminal covers are securely replaced after connecting the input power and motor cables. WARNING: Verify that the SED2 and motor are correctly rated for the input power voltage. Verify that the input power cables are correctly sized for the anticipated use. Confirm that appropriate circuit breakers or fuses have been installed between the input power supply and the SED2. Never use high-voltage insulation test equipment on any cables connected to the SED2. 24 Siemens Building Technologies, Inc.

35 Electrical Installation Operation in Ungrounded Systems IP20 and NEMA Type 1 SED2s can operate in ungrounded systems if the Y capacitor is disconnected or removed. They remain in operation when an input ground fault occurs. In the event of an output ground fault, the SED2 switches off and displays fault code F0001. NOTE: IP54, NEMA Type 12 SED2s cannot operate in ungrounded systems. Ungrounded Systems and Y Capacitor In ungrounded systems, remove or disconnect the Y capacitor (and install an output choke/load reactor) per Figures 8 through VFD060R1 Figure 8. Disconnecting Y Capacitor in SED2 Frame Size A. Siemens Building Technologies, Inc. 25

36 ON SED2 VFD Startup, Operation, and Maintenance Manual VFD0061R1 Figure 9. Disconnecting Y Capacitor in SED2 Frame Size B and C. PE Torx driver T20 M4 Screw 5192Z03en Figure 10. Disconnecting Y Capacitor in SED2 Frame Size D and E. 26 Siemens Building Technologies, Inc.

37 Electrical Installation T30 Torx screwdriver M6 VFD0063R1 Figure 11. Disconnecting Y Capacitor in SED2 Frame Size F. Siemens Building Technologies, Inc. 27

38 SED2 VFD Startup, Operation, and Maintenance Manual Access to Connection Terminals To access input power and output motor connection terminals, remove the cover, operator panel, terminal cover, and I/O module per Figures 12 through 17. The I/O module is located under the operator panel. In frame sizes A through C/IP20, and NEMA Type 1 SED2s, the operator panel directly connects to the I/O module. In frame sizes D through F, and all IP54 NEMA Type 12 SED2s, the operator panel connects to the I/O module via a cable. In all SED2s, the control module is located under the I/O module. 1 2 VFD0064R1 VFD0065R1 Figure 12. Removing Operator Panel (All Frame Sizes) VFD0066R1 VFD0067R1 Figure 13. Removing Terminal Cover (All Frame Sizes). Figure 14. Removing I/O Module (All Frame Sizes). 28 Siemens Building Technologies, Inc.

39 Electrical Installation 1 VFD0068R1 Figure 15. Removing Cover on Frame Sizes B and C VFD0069R1 6 Figure 16. Accessing Connection Terminals for Frame Sizes D and E. Siemens Building Technologies, Inc. 29

40 SED2 VFD Startup, Operation, and Maintenance Manual VFD0070R1 Figure 17. Accessing Connection Terminals for Frame Size F. 30 Siemens Building Technologies, Inc.

41 Electrical Installation Motor Frequency and Unit of Measurement DIP Switches In all versions of the SED2, DIP switches for selecting motor frequency and unit of measurement are located on the control module under the I/O module. (See Access to Connection Terminals section for disassembly instructions.) DIP Switch Position Function 2 * ON OFF North American operation (60 Hz, hp). European operation (50 Hz, kw), factory default. 1 OFF Not for customer use. NOTE: This switch must be OFF for correct operation. * Set DIP switch 2 ON (60 Hz, hp) for all North American installations. DIP SWITCHES ON 1 2 VFD0145R1 Figure 18. Location of Motor Frequency and Unit of Measurement DIP Switches on Control Module. Siemens Building Technologies, Inc. 31

42 SED2 VFD Startup, Operation, and Maintenance Manual Input Power and Motor Terminal Layout DANGER: The following terminals carry hazardous voltages even when the SED2 is not running: Input power terminals: L1, L2, L3 Motor terminals: U, V, W Link terminals: DC-, DC+/B+, DC/R+, B- (not for customer use) L3 R+ DC B- L2 DC+ DC- L1 U V W VFD0071R1 PE (Ground) (Ground) Figure 19. Input Power and Motor Terminal Layout for SED2 Frame Size A. L3 L2 L1 DC- DC+ B+ DC R+ B - U V W PE VFD0072R1 PE (Ground) (Ground) Figure 20. Input Power and Motor Terminal Layout for SED2 Frame Size B and C. 32 Siemens Building Technologies, Inc.

43 Electrical Installation L1 L2 L3 DC- DC+ B+ DC R+ B- U V W VFD0073R1 PE (Ground) (Ground) Figure 21. Input Power and Motor Terminal Layout for SED2 Frame Size D and E. R+ B+ B+ DC- B- DC+ DC+ DC+ L1 L2 L3 U V W PE VFD0074R1 PE (Ground) (Ground) Figure 22. Input Power and Motor Terminal Layout for SED2 Frame Size F. Siemens Building Technologies, Inc. 33

44 SED2 VFD Startup, Operation, and Maintenance Manual Tightening Torque for Input Power and Motor Connections Frame size A B C D E F Tightening torque lb-in (Nm) 9.7 (1.1) 13.3 (1.5) 19.9 (2.25) 88.5 (10) max (10) max. 442 (50) Cable Cross-Sections for Input Power and Motor Cables Table 5. Cable Cross-Sections for Input Voltage Range 3Ø AC 200V through 240V. Maximum Output rating kw (hp) Input Power Cable Minimum Cross- Section AWG (mm 2 ) Maximum Cross- Section AWG (mm 2 ) Minimum Cross- Section AWG (mm 2 ) Motor Cable Maximum Cross- Section AWG (mm 2 ) 0.37 (.50) 17 (1) 13 (2.5) 17 (1) 13 (2.5) 0.55 (.75) 17 (1) 13 (2.5) 17 (1) 13 (2.5) 0.75 (1.0) 17 (1) 13 (2.5) 17 (1) 13 (2.5) 1.1 (1.5) 17 (1) 9 (6) 17 (1) 9 (6) 1.5 (2.0) 15 (1.5) 9 (6) 17 (1) 9 (6) 2.2 (3.0) 13 (2.5) 9 (6) 17 (1) 9 (6) 3 (4.0) 11 (4) 7 (10) 15 (1.5) 7 (10) 4 (5.0) 11 (4) 7 (10) 11 (4) 7 (10) 5.5 (7.5) 11 (4) 7 (10) 11 (4) 7 (10) 7.5 (10) 7 (10) 2 (35) 7 (10) 2 (35) 11 (15) 5 (16) 2 (35) 16 (5) 2 (35) 15 (20) 5 (16) 2 (35) 5 (16) 2 (35) 18.5 (25) 3 (25) 2 (35) 5 (16) 2 (35) 22 (30) 2 (35) 2 (35) 2 (35) 2 (35) 30 (40) 0 (50) -5 (150) 0 (50) -5 (150) 37 (50) -2 (70) -5 (150) -2 (70) -5 (150) 45 (60) -2 (70) -5 (150) -3 (95) -5 (150) 34 Siemens Building Technologies, Inc.

45 Electrical Installation Table 6. Cable Cross-Sections for Input Voltage Range 3Ø AC 380V through 480V. Maximum Output rating kw (hp) Input Power Cable Minimum Cross- Section AWG (mm 2 ) Maximum Cross- Section AWG (mm 2 ) Minimum Cross- Section AWG (mm 2 ) Motor Cable Maximum Cross- Section AWG (mm 2 ) 0.37 (.50) 17 (1) 13 (2.5) 17 (1) 13 (2.5) 0.55 (.75) 17 (1) 13 (2.5) 17 (1) 13 (2.5) 0.75 (1.0) 17 (1) 13 (2.5) 17 (1) 13 (2.5) 1.1 (1.5) 17 (1) 13 (2.5) 17 (1) 13 (2.5) 1.5 (2.0) 17 (1) 13 (2.5) 17 (1) 13 (2.5) 2.2 (3.0) 17 (1) 9 (6) 17 (1) 9 (6) 3 (4.0) 17 (1) 9 (6) 17 (1) 9 (6) 4 (5.0) 17 (1) 9 (6) 17 (1) 9 (6) 5.5 (7.5) 13 (2.5) 7 (10) 13 (2.5) 7 (10) 7.5 (10) 11 (4) 7 (10) 11 (4) 7 (10) 11 (15) 9 (6) 7 (10) 9 (6) 7 (10) 15 (20) 7 (10) 2 (35) 7 (10) 2 (35) 18.5 (25) 7 (10) 2 (35) 7 (10) 2 (35) 22 (30) 5 (16) 2 (35) 5 (16) 2 (35) 30 (40) 3 (25) 2 (35) 3 (25) 2 (35) 37 (50) 3 (25) 2 (35) 2 (35) 2 (35) 45 (60) 2 (35) -5 (150) 2 (35) -5 (150) 55 (75) -2 (70) -5 (150) -2 (70) -5 (150) 75 (100) -2 (70) -5 (150) -3 (95) -5 (150) 90 (125) -2 (70) -5 (150) -3 (95) -5 (150) Siemens Building Technologies, Inc. 35

46 SED2 VFD Startup, Operation, and Maintenance Manual Table 7. Cable Cross-Sections for Input Voltage Range 3Ø AC 500V through 600V. Maximum Output rating kw (hp) Minimum Cross- Section AWG (mm 2 ) Input Power Cable Maximum Cross- Section AWG (mm 2 ) Minimum Cross- Section AWG (mm 2 ) Motor Cable Maximum Cross- Section AWG (mm 2 ) 0.75 (1.0) 17 (1) 7 (10) 17 (1) 7 (10) 1.1 (1.5) 17 (1) 7 (10) 17 (1) 7 (10) 1.5 (2.0) 17 (1) 7 (10) 17 (1) 7 (10) 2.2 (3.0) 17 (1) 7 (10) 17 (1) 7 (10) 3 (4.0) 17 (1) 7 (10) 17 (1) 7 (10) 4 (5.0) 17 (1) 7 (10) 17 (1) 7 (10) 5.5 (7.5) 15 (1.5) 7 (10) 15 (1.5) 7 (10) 7.5 (10) 13 (2.5) 7 (10) 13 (2.5) 7 (10) 11 (15) 11 (4) 7 (10) 11 (4) 7 (10) 15 (20) 9 (6) 2 (35) 9 (6) 2 (35) 18.5 (25) 9 (6) 2 (35) 9 (6) 2 (35) 22 (30) 7 (10) 2 (35) 7 (10) 2 (35) 30 (40) 5 (16) 2 (35) 5 (16) 2 (35) 37 (50) 3 (25) 2 (35) 5 (16) 2 (35) 45 (60) 3 (25) -5 (150) 3 (25) -5 (150) 55 (75) 0 (50) -5 (150) 2 (35) -5 (150) 75 (100) -2 (70) -5 (150) 0 (50) -5 (150) 90 (125) -2 (70) -5 (150) 0 (50) -5 (150) 36 Siemens Building Technologies, Inc.

47 Electrical Installation Input Power Connection DANGER: As supplied, the SED2 must be grounded (per IEC 536, Class 1, NEC and other relevant industry standards). Extremely hazardous conditions can occur if the SED2 is not correctly grounded. Use only permanently wired input power connections. Only hard-wired input power connections are permissible. Use Class 1 60/75 copper wire only. The cross-section of the ground-bonding conductor must be at least equal to the input power cables. The following terminals can carry hazardous voltages even when the SED2 is not running: Input power terminals: L1, L2, L3 Motor terminals: U, V, W Link terminals: DC-, DC+/B+, DC/R+, B- (not for customer use) Connect input power to SED2 terminals L1, L2, and L3 (Figures 19 through 22). Siemens Building Technologies, Inc. 37

48 SED2 VFD Startup, Operation, and Maintenance Manual Motor Cable Length Maximum motor cable length is 164 ft (50m). Motor cable length is given to ensure performance of only the SED2, not the suitability of the motor when connected to a SED2 at this distance.! 1. Never run control or drive input wires in the same conduit as the drive output wires. 2. Keep the distance from the drive to the motor as short as possible to maximize motor life. 4. If a disconnect is mounted on the load side of your drive, it is desirable to wire an auxiliary contact to the drive that will disable drive operation when the disconnect opens. (The wiring for this contact must not be run in the same conduit as the drive output wires). SED2 M VFD0014R2 3. If needed, use SBT-specified input line reactors to ensure a good impedance match with your drive. 5. Inverter duty motors are recommended. Install motors within their guidelines. Use dv/dt filters, output reactors, or other load conditioners as applicable or as specified by the motor manufacturer. Figure 23. Motor Cable Installation Notes. NOTE: If connecting multiple motors to one SED2, the total length of the individual motor cables must not exceed the maximum motor cable length. 38 Siemens Building Technologies, Inc.

49 Electrical Installation Motor Connection (Wye "Y"/Star or Delta Configuration) DANGER: Do not use the SED2 with a motor of higher nominal power rating than the SED2, or a nominal power less than half that of the SED2. Only operate the SED2 when the nominal current (P0305) is set to match motor rating continuous current. The motor nameplate indicates the required supply voltage and method of connection. In general, larger 400/690V motors connect in a delta ( ) configuration and smaller 230/400V motors connect in a Wye Y or star configuration (Figure 24). Connect motor wiring to SED2 terminals U, V, and W (Figures 19 through 22). MOTOR TERMINALS U1 V1 W1 U1 V1 W1 VFD0029R2 W2 U2 V2 W2 U2 V2 Wye "Y" Figure 24. Delta and Star (Wye, Y) Motor Connections. Siemens Building Technologies, Inc. 39

50 SED2 VFD Startup, Operation, and Maintenance Manual Direction of Motor Rotation To change the direction of motor rotation, cross-connect two of the output conductors on the SED2 (Figure 25). This is the desired method for changing rotation. NOTE: The Reverse Output Phase Sequence parameter (P1820) can also reverse the direction of rotation. However, if the SED2 is reset to factory defaults, P1820 is reset to OFF. U U SED2 V V M W W U V VFD0030R1 SED2 V W U W M Figure 25. Direction of Motor Rotation. 40 Siemens Building Technologies, Inc.

51 Electrical Installation Motor Overload Protection WARNING: The SED2 is capable of providing internal motor overload protection in accordance with UL508C, Section 42. Accurately configure motor parameters for the motor overload protection to operate correctly. See Motor I 2 t Temperature Reaction parameter (P0610); I 2 t is On by default. Motor overload protection also can be provided using an external PTC temperature-thermistor sensor (disabled by default via Motor Temperature Sensor parameter (P0601)). During operation below nominal speed, the cooling effect of the fans mounted to the motor shaft is reduced. Therefore, most motors require de-rating if operated continuously at low frequencies. To ensure that motors are protected from overheating under these conditions, mount a PTC temperature-thermistor sensor to the motor and connect it to the control terminals of the SED2. NOTE: To enable the switch-off function with a PTC temperaturethermistor sensor, set Motor Temperature Sensor parameter (P0601) to 1 for PTC temperature-thermistor sensor. Use a shielded cable to connect the PTC temperature-thermistor sensor. 14 SED2 CONTROL TERMINALS VFD0031R1 15 Figure 26. External Motor Overload Protection. Siemens Building Technologies, Inc. 41

52 SED2 VFD Startup, Operation, and Maintenance Manual Connection of Multiple Motors The SED2 can control several motors in parallel as long as all of the motors have the same power rating. When multiple motors connect to the SED2 in parallel, the motors cannot operate individually. NOTES: SED2 5192Z10 1. When determining the required power, take into account the total current from all the motors (or the total of all ratings). 2. The sum of all individual motor cable lengths must not exceed the maximum motor cable length. M 1 M 2 M 3 M 4 M n I M1..M n I SED2, max. P M1..M n P SED2, max. Figure 27. SED2 Connection to Multiple Motors. 42 Siemens Building Technologies, Inc.

53 Electrical Installation Analog Input DIP Switches WARNING: When using analog inputs, the DIP switches must be correctly set and the analog inputs correctly configured before being enabled. If this is not done, the motor may start inadvertently. After completing settings for motor frequency and unit of measurement DIP switches, and wiring for input power and motor connections, reattach the I/O module. For all versions of the SED2, the DIP switches used to configure the analog inputs are located on the I/O module. (See Access to Connection Terminals section for disassembly instructions.) DIP Switch Position Function 1 2 OFF OFF ON OFF OFF ON Analog Input 1, voltage 0 to 10 Vdc, factory default. Analog Input 1, Ni 1000 sensor input with parameter setting P0756[0]=5. Analog Input 1, current 0 to 20 ma. Analog Input 2, voltage 0 to 10 Vdc, factory default. Analog Input 2, Ni 1000 sensor input with parameter setting P0756[1]=5. Analog Input 2, current 0 to 20 ma. Siemens Building Technologies, Inc. 43

54 SED2 VFD Startup, Operation, and Maintenance Manual DIP SWITCHES ON VFD0146R Figure 28. Location of Analog Input DIP Switches on I/O Module. Control Terminal Connections Control Terminal Layout The control terminals (Figures 29 and 30) are located on the I/O module. The I/O module is identical for all versions of the SED2. The I/O module is located under the operator panel. (See the Access to Connection Terminals section for disassembly instructions.) Connect control wiring to SED2 control terminals 1 through 30 per sitespecific drawings. See the Analog and Digital I/O Control Terminal Connections section for examples of connections. 44 Siemens Building Technologies, Inc.

55 Electrical Installation NOTE: 1. Use only shielded cables for control cables. 2. Route control cables in separate cable trunks at least 7-3/4 inches (20 cm) away from motor and power cables. After completing analog input DIP switch settings and wiring for control terminal connections, reattach the SED2 cover and operator panel. AIN1 On = [A], 0-20 ma Off = [V], 0-10 V ON RL1 NC RL1 NO RL1 RL2 COM NC RL2 NO RL2 COM AIN2 On = [A], 0-20 ma Off = [V], 0-10 V AOUT AOUT PTC A PTC B DIN 5 DIN 6 AOUT AOUT ISO V P+ N V 0V AIN 1+ AIN 1- DIN 1 DIN 2 DIN 3 DIN 4 ISO 24V AIN 2+ AIN 2- VFD0017R Figure 29. SED2 Control Terminals on I/O Module. NOTES: 1. Analog inputs 1 and 2 can be optionally configured for direct connection of a Ni 1000 temperature sensor. The sensor connects between terminals 4 and 2 or 11 and to 10 Vdc analog inputs connect between terminals 2 and ma to 20 ma and 4 ma to 20 ma analog inputs connect between terminals 3 and 4. When using a 4 ma to 20 ma input, DIP switches must be set to appropriate input. Siemens Building Technologies, Inc. 45

56 SED2 VFD Startup, Operation, and Maintenance Manual Drive Parameters P0003 User acces level P0010 Commissioning parameter filter r0026 VFD DC-link voltage r P0040 Energy consumption meter P0100 US / Europe r r0209 Performance data P P1028 Frequency setpoint P P1110 Frequency adjustment 200 to 240V, 3OAC 380 to 480V, 3OAC 500 to 600V, 3OAC L1 L2 L3 Analog Inputs 1 and 2 P P0762 L1L2L3 PE Ni 1000 Ni 1000 Digital Input P0700 Command source P P0706 P0705 counter P P0725 NPN / PNP P P0708 Analog Inputs 1 and 2 configured as digital inputs PE V: 0 to 10V 2 to 10V I: 0 to 20 ma 4 to 20 ma V: 0 to 10V 2 to 10V I: 0 to 20 ma 4 to 20 ma AI1 0V AI2 +10Vdc +0Vdc A/D A/D 0V 28 Isolated 0V (output) 9 Isolated 50 ma at 18 to 32Vdc (output) 5 DI1 6 DI2 7 DI3 8 DI4 16 DI5 17 DI6 opto isolated DC/R+ DC/B+ Motor Parameters r r0035 Motor performance data P P0313 Standard data P0340 Calculation of motor parameters P P0640 Motor protection P1910 Motor data identification P2000 Reference frequency CPU + 12 D/A AO D/A AO V, 2A or 230V, 1A 20 U V W PE PE 21 Relay Output V, 2A or 230V, 1A M 3 Drive Features P1270 Enable essential mode P P1212 Automatic restart V: 0 to 10V 2 to 10V I: 0 to 20 ma 4 to 20 ma V: 0 to 10V 2 to 10V I: 0 to 20 ma 4 to 20 ma Relay Output 2 Analog Output r P0781 Digital Output P P0732 r r0748 BOP r0000 P0005 r r0039 PTC P0601 PID P2200 Enable PID P P2231 Fixed setpoint P r2260 PID setpoint P P2305 Standard setpoint P r2272 PID feedback Motor PTC RS-485 BOP (Standard) AOP (Optional) AOP See AOP Operating Instructions Communications P r Figure 30. SED2 Terminal Connections and Related Parameters. 46 Siemens Building Technologies, Inc.

57 Electrical Installation Analog and Digital I/O Control Terminal Connections Figures 31 through 35 show typical analog and digital input/output control terminal connections. WARNING: When using analog inputs, the DIP switches must be correctly set and the analog inputs correctly configured before enabling them. If this is not done, the motor may start inadvertently. VFD0048R1 PNP or NPN DIN1 DIN2 DIN3 DIN4 DIN5 DIN6 DC-ISOLATED ISOLATED +24 Vdc (OUTPUT) ISOLATED 0 Vdc (OUTPUT) Figure 31. Digital Inputs 1 through 6. EXTERNAL 0-10V EXTERNAL 0-20 ma VFD0022R SPEED POTENTIOMETER V 2 0 V VFD 24V dc Powered 0-20 ma Device (Power consumption cannot exceed 100 ma) 2 ma 3 4 VFD0050R1 4.7k OHM MINIMUM 3 AIN1+ 4 AIN1-10 AIN2+ 11 AIN2- A/D A/D VFD0021R1 24V ac Power 9 28 Figure 32. Analog Inputs 1 and 2. Siemens Building Technologies, Inc. 47

58 SED2 VFD Startup, Operation, and Maintenance Manual VFD0049R1 DIN7 3 4 DIN Figure 33. Connection of Analog Inputs 1 and 2 as Digital Inputs 7 and 8. VFD0150R1 120V, 2A or 230V, 1A 120V, 2A or 230V, 1A RELAY OUTPUT 1 RELAY OUTPUT 2 Figure 34. Digital Outputs 1 and 2. VFD0051R1 D / A D / A + 12 AOUT AOUT2-27 V: 0-10 V 2-10 V I: 0-20mA 4-20mA V: 0-10 V 2-10 V I: 0-20mA 4-20mA ANALOG OUTPUT r P0781 Figure 35. Analog Outputs 1 and Siemens Building Technologies, Inc.

59 Parameters Parameters Overview The SED2 uses parameters to define the required operating characteristics, such as motor data, ramp times, and maximum and minimum frequency. Users enter and modify the SED2 parameters using the Basic Operator Panel, the Advanced Operator Panel, or a serial interface. Each parameter consists of the letter "r" or "P", followed by four numbers, such as r0000 or P0010. The letter "r" identifies read-only parameters. The letter "P" identifies programmable parameters. Parameter Structure Figure 36 depicts the structure of the SED2 parameters. User Access Level parameter (P0003) selects the access level for using the parameters (1=standard, 2=extended, or 3=expert). The access level selected via parameter P0003 determines the number of parameters that are accessible by the user. For most applications, the Standard (1) and Extended (2) levels are sufficient. The factory default setting is P0003=1 (Standard). The filters of Parameter Filter parameter (P0004) categorize the parameters that are available via the access level according to functionality. The filters/categories enable a more focused operational approach. If parameter P0004=0 for no filter/category, then all parameters for a selected user access level are available. NOTE: Some parameters are intended for commissioning only and can be viewed as a function of this filter. In order to set these parameters, P0010 must be set to 1 (quick commissioning). Parameter Indexes Certain parameters have indexes. The indexes provide subsets of a particular parameter function and group together closely related parameter type information. The Parameter Reference Guide (Document Number ) lists any indexes associated with a parameter. Siemens Building Technologies, Inc. 49

60 SED2 VFD Startup, Operation, and Maintenance Manual The following indexes are associated with P0700, P1000, and digital input and output parameters: IN000 (AUTO), 1st command data set (CDS) IN001 (HAND), 2nd command data set (CDS) The following indexes are associated with analog input and output parameters: IN000, Analog input 1, AO1 IN001, Analog input 2, AO2 NOTE: Throughout this manual, a parameter number followed by [0] or [1] denotes index number 000 or 001 respectively. P0004=22 PI Controller P0004=2 Inverter Unit P0004=21 Alarms, Warnings, and Monitoring P0003=3, Access Level Expert P0004=3 Motor Data P0003=2, Access Level Extended P0004=20 Communication P0003=1, Access Level Standard P0004=7 Commands and Digital I/O P0004=13 Motor Control P0004=8 Analog I/O P0004=12 Drive Features P0004=10 Setpoint Channel and Ramp Generator VFD0019R1 P0004=8, P0003=2 Parameters in Access Levels 1 and 2 associated with Analog I/O are Available P0004=8 Analog I/O P0004=8, P0003=3 Parameters in Access Levels 1, 2, and 3 P0004=8, P0003=1 associated with Parameters in Analog I/O are Available Access Levels 1 associated with Analog I/O are Available Figure 36. SED2 Parameter Access Levels and Filters. 50 Siemens Building Technologies, Inc.

61 SED2 Operator Panels SED2 Operator Panels Overview The SED2 includes the Basic Operator Panel (BOP) mounted as standard. An Advanced Operator Panel (AOP) is available as an option. Figure 37. Basic Operator Panel (BOP). Figure 38. Advanced Operator Panel (AOP). NOTES: 1. On initial startup, the SED2 display values alternate between 0.0 Hz (zero) and the speed it would be running if it were given a start command. 2. The BOP or AOP can connect to or disconnect from the SED2 without switching off power. Basic Operator Panel (BOP) The BOP provides access to the parameters of the SED2 and allows for application-specific settings of the SED2. The parameters and measured values are shown in a 5-digit LCD display. The BOP can mount directly onto the SED2 or, alternatively, it can mount into a control cabinet door using a special installation kit (SED2-DOOR-KIT1 or SED2-DOOR-KIT2). The BOP cannot store parameter data. Siemens Building Technologies, Inc. 51

SED2 Variable Frequency Drives

SED2 Variable Frequency Drives May 9, 0 SED Variable Frequency Drives Description The SED variable frequency drives are designed specifically for HVA applications. The SED supports a wide variety of digital and analog I/O for diverse

More information

HVAC Products. Introducing the SED2 Variable Frequency Drives

HVAC Products. Introducing the SED2 Variable Frequency Drives HVAC Products Introducing the SED2 Variable Frequency Drives Designed Specifically for HVAC Applications From a global leader in drives technology and innovation, now comes a drive specifically configured

More information

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

SED2 Variable Frequency Drives with Electronic (E) Bypass Options SED2 Variable Frequency Drives with Electronic (E) Options Description The E- Options are companion packages for the family of SED2 Variable Frequency Drives (s). For information on the family of SED2

More information

SED2 Variable Frequency Drives

SED2 Variable Frequency Drives Building Technologies SED2 Variable Frequency Drives More standard features Means better control of HVAC applications The global leader in Heating, Ventilation and Air Conditioning (HVAC) products and

More information

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options Submittal Sheet SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options Description The Bypass Options are companion packages for the family of SED2 Variable Frequency Drives. For information

More information

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

SED2 VFD NEMA Type 3R Bypass/Air Conditioner SED2 VFD NEMA Type 3R Bypass/Air Conditioner Description The NEMA Type 3R Bypass with Air Conditioner allows SED2 to be employed in a harsh environment. The SED2 is designed specifically for HVAC applications

More information

SED2 VFD NEMA Type 3R and 3R Harsh Environment (3RHE) Bypass Operating Instructions

SED2 VFD NEMA Type 3R and 3R Harsh Environment (3RHE) Bypass Operating Instructions SED2 VFD NEMA Type 3R and 3R Harsh Environment (3RHE) Bypass Operating Instructions Item Number 125-3377, Rev. FA SED2 VFD NEMA Type 3R and Type 3R Harsh Environment (3RHE) Bypass Operating Instructions

More information

SED2 Variable Frequency Drives

SED2 Variable Frequency Drives SED2 Variable Frequency Drives Startup Procedure and Checklist Document No. 155-718 Table of Contents Prerequisites...1 Preparing for SED2 VFD Startup...1 HVAC Startup Procedure for SED2 with Bypass Option...4

More information

BT300 HVAC Drives. Designed for HVAC. Description. Technical Specification Sheet Document No March 4, 2013

BT300 HVAC Drives. Designed for HVAC. Description. Technical Specification Sheet Document No March 4, 2013 Technical Specification Sheet Document No. 149-711 March 4, 2013 BT300 HVAC Drives Designed for HVAC Figure 1. BT300 HVAC Drive without and with Integral Disconnect. Description Siemens Industry's BT300

More information

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1 IO-PT4 I/O Expansion Module 4 PT100 Inputs (-50 to 460 C) The IO-PT4 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 4 PT100 inputs

More information

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options BT300 HVAC Drives Electronic Bypass (E-Bypass) Options Description The BT300 Electronic Bypass (E-Bypass) Options are companion packages for the family of BT300 Variable Frequency Drives (VFDs). For information

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

SED2 Variable Frequency Drives

SED2 Variable Frequency Drives SED2 Variable requency Drives Description The SED2 variable frequency drives are designed specifically for HVA applications. The SED2 supports a wide variety of digital and analog I/O for diverse control

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase Characteristics variable speed drive ATV310-0.75 kw - 1 hp - 380...460 V - 3 phase Main Range of product Altivar Easy 310 Product or component type Product specific application Assembly style Device short

More information

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ATV12H018M2 variable speed drive ATV kW hp V - 1ph Characteristics variable speed drive ATV12-0.18kW - 0.25hp - 200..240V - 1ph Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly

More information

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual User s Manual ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1 200 HP)

More information

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase Characteristics variable speed drive ATV310-3 kw - 4 hp - 380...460 V - 3 phase Complementary Product destination Main Range of product Altivar Easy 310 Product or component type Product specific application

More information

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW) Characteristics soft starter-ats22-control 220V-power 230V(15kW)/400...440V(30kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component

More information

Table of Contents. Safety. Attention. Warnings

Table of Contents. Safety. Attention. Warnings Solstart Miniature Soft Starter 8-58A, 220-600V Instruction Manual Ver. 21.2. 2002 Table of Contents Page Subject 3 Starter Selection 4 Installation Notes 5 Wiring 6 Starter Settings & Start-up Procedure

More information

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2 dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Operating Instructions Safety information 1 General 2 Mechanical installation 3 Electrical

More information

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink Characteristics variable speed drive ATV12-2.2kW - 3hp - 200..240V - 3ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly

More information

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - on base plate Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.6 11/2013 A5E32845290B AA

More information

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs The IO-DI8-TO8 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 8 digital inputs,

More information

PowerFlex 400 AC Drive Guide Specification

PowerFlex 400 AC Drive Guide Specification PowerFlex 400 AC Drive Guide Specification Adjustable Frequency Drives with Bypass 3.0 50HP @ 208V AC 3.0 350HP @ 480V AC PART 1 GENERAL 1.01 Quality Assurance A. The manufacturer shall have minimum 5

More information

SINUS PENTA 6. ACCESSORIES 6.1. BRAKING RESISTORS APPLICATION TABLES 111/209

SINUS PENTA 6. ACCESSORIES 6.1. BRAKING RESISTORS APPLICATION TABLES 111/209 INSTALLATION. ACCESSORIES.. BRAKING RESISTORS... APPLICATION TABLES From size S to size S, inverters are supplied with a built-in braking module. The braking resistor is to be connected outside the inverter

More information

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate Characteristics variable speed drive ATV12-0.75kW - 1hp - 200..240V - 3ph - on base plate Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

COMBIMASTER 411 & MICROMASTER 411

COMBIMASTER 411 & MICROMASTER 411 COMBIMASTER 411 & MICROMASTER 411 English Getting Started Guide Issue 07/05 This Getting Started Guide allows for easy and efficient commissioning of the Siemens COMBIMASTER 411 and MICROMASTER 411 Inverters.

More information

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW) Characteristics soft starter-ats22-control 220V-power 230V(18.5kW)/400...440V(37kW)/500V(45kW) Price* : 683.00 GBP Main Range of product Altistart 22 Product or component type Product destination Product

More information

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter. www.sordselectric.com MA7200 Sensorless Vector AC Inverter Features and Benefits Sensorless Vector The MA7200 has precise speed and torque control for the most demanding system performance and simple set-up

More information

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated

More information

Siemens Industrial s

Siemens Industrial s SINAMICS G130 Operating Instructions 05/2010 SINAMICS Siemens Industrial s Sinusoidal filter Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical

More information

SMVector Additional I/O Module Installation and Operation Manual

SMVector Additional I/O Module Installation and Operation Manual SMVector Additional I/O Module Installation and Operation Manual About These Instructions This documentation applies to the optional Additional I/O module for the SMVector inverter and should be used in

More information

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs The IO-DI8-TO8 and IO-DI8-TO8-L are I/O expansion modules that can be used in conjunction with specific Unitronics OPLC controllers. The

More information

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink Product datasheet Characteristics ATV12H075M3 variable speed drive ATV12-0.75kW - 1hp - 200..240V - 3ph - with heat sink Complementary Main Range of product Altivar 12 Product or component type Product

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW) Characteristics soft starter-ats22-control 220V-power 230V(4kW)/400...440V(7.5kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component

More information

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D Specification Number: 23 09 33 Product Name: FRENIC-Eco AC Drives for Variable Torque Fan & Pump Applications (1-125Hp at 208/230V and 1-900Hp at 460V) PART 1: GENERAL 1.01 SUMMARY A. This specification

More information

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW) Product data sheet Characteristics ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/400...440V(37kW) Complementary Assembly style Function available Power supply voltage limits Main Range of

More information

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN 1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,

More information

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.7 04/2014 A5E00331462A Legal

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW) Product datasheet Characteristics ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/400...440V(7.5kW) Complementary Assembly style Function available Supply voltage limits Main Range of product

More information

Easy To Use OEMS Take Note

Easy To Use OEMS Take Note MA7200 Features Sensorless Vector Precise speed and torque control for the most demanding system performance. Simple set-up through autotuning function. The MA7200 can be operated in sensorless vector

More information

S66 Series Electronic Fan Speed Control

S66 Series Electronic Fan Speed Control FANs 121, 125, 1628.3 Product/Technical Bulletin S66 Issue Date 0918 S66 Series Electronic Fan Speed Control The S66 Series Electronic Fan Speed Control is designed to modulate the speed of single-phase,

More information

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection Product datasheet Characteristics ATS22C17Q Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product

More information

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/ Symmetra PX 160 Maintenance Bypass Enclosure Installation 05/2014 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries

More information

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW. CENTRIFLOW PUR 3D (A, PLUG B, C, D) FAN GMPM FC101 AND SLIDE IN FREQUENCY ROTOR CASSETTE CONVERTER QUICK GUIDE FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS

More information

PowerLogic High Density Metering System 1-Meter Enclosure

PowerLogic High Density Metering System 1-Meter Enclosure PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V) E510 Compact Drive IP 20/ NEMA 1 0.5-40 HP (230V) 1-75 HP (460V) Control Mode Application & Selection Guide The E510 compact AC Drive is an easily configurable product that controls many motor driven applications.

More information

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001 SLATE Digital I/O Module R8001D4001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform

More information

Analog Monitor Installation Manual

Analog Monitor Installation Manual Analog Monitor Installation Manual Part Number: 144-23919 Copyright 2011 Magnetek 1. Preface and Safety Magnetek manufactures products used as components in a wide variety of industrial systems and equipment.

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

User guide. SRC Pumpdrive with SmartRun functionality, dedicated for waste water pump station

User guide. SRC Pumpdrive with SmartRun functionality, dedicated for waste water pump station User guide SRC 311 - Pumpdrive with SmartRun functionality, dedicated for waste water pump station Table of Contents Table of Contents Introduction and Safety...2 SRC 311...2 Electromagnetic Compatibility...4

More information

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS SINAMICS G130 Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Voltage Sensing Module 10 (VSM10) Mechanical installation 3 Electrical installation 4 Technical

More information

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp) Characteristics softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp) Main Range of product Altistart 22 Product or component type Product destination Product specific application

More information

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVLF

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVLF AC variable speed drive for use with AC induction motors V/F control + Auto-torque compensation function Input voltage ranges: 1-ph 200~240V, 3-ph 380~480V 2 frame sizes Conforms to EMC standard EN 61800-3

More information

Zenith DS9000 Dispensing System

Zenith DS9000 Dispensing System Page Date: 04/2009 Zenith DS9000 Dispensing System Installation & Operation Manual Page 2 Table of Content Introduction... 3 Control Specification... 4 Wiring Diagram... 5 Wiring Instructions... 6 Field

More information

SMVector Additional I/O Module Installation and Operation Manual

SMVector Additional I/O Module Installation and Operation Manual SMVector Additional I/O Module Installation and Operation Manual About These Instructions This documentation applies to the optional Additional I/O module for the SMVector inverter and should be used in

More information

PumpDrive. Self -cooling, motor-independent frequency inverter. Brief Instructions

PumpDrive. Self -cooling, motor-independent frequency inverter. Brief Instructions Brief Instructions PumpDrive 4070.801/2--11 Self -cooling, motor-independent frequency inverter Mounting variants: Motor mounting (MM) Wall mounting (WM) Cabinet mounting (CM) Brief Instructions 1 About

More information

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVFF

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVFF ype VariFlex 3 RVFF RVFF AC variable speed drive for use with AC induction motors Sensorless vector control or V/F, SLV, PMSLV with space vector PWM mode Input voltage ranges: 3-ph 480VAC 150%/1Hz (vector

More information

AF-600 FP TM Fan & Pump Drive. (230V to 60HP, 460/575V to 125HP Operating Instructions

AF-600 FP TM Fan & Pump Drive. (230V to 60HP, 460/575V to 125HP Operating Instructions GE AF-600 FP TM Fan & Pump Drive (230V to 60HP, 460/575V to 125HP Operating Instructions Safety Safety WARNING HIGH VOLTAGE! Frequency converters contain high voltage when connected to AC mains input power.

More information

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS SINAMICS G130 Operating instructions 03/2011 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Voltage Sensing Module 10 (VSM10) Mechanical installation 3 Electrical installation 4 Technical

More information

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs The IO-DI8-RO8 and IO-DI8-RO8-L are I/O expansion modules that can be used in conjunction with specific Unitronics OPLC controllers. The

More information

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Characteristics variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Main Range of product Altivar 32 Product or component type Product destination Product specific application

More information

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h Characteristics soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h Complementary Assembly style Function available Power supply voltage limits Main Range of product Altistart

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

QUICK START GUIDE. vau4/3. Frequency converter.   operating instructions /12 operating instructions QUICK START GUIDE Frequency converter vau4/3 28100241101 12/12 1 Safety information Warning of electrical shock! Danger to life! Electrical shock can cause serious injury or even

More information

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection Product datasheet Characteristics ATS22D75S6U Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808THS Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2 Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,

More information

P216 Series Condenser Fan Speed Controller

P216 Series Condenser Fan Speed Controller P216 Series Condenser Fan Speed Controller Installation Instructions P216xxx-x Part No. 24-85895-18, Rev. D Issued 27 August 2015 Applications Refer to the QuickLIT website for the most up-to-date version

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018 Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018 Tags: P-8 1800RPM Premium Efficient Motor 460/3/60 Pump and Motor Weight: 183lbs

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Wide Modules Installation Guide UIS-WCB1 Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide as Uni-I/O

More information

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P dv/dt filter plus Voltage Peak Limiter Operating Instructions Mechanical installation 3 Electrical installation 4 Maintenance and servicing 5 Technical

More information

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection Product datasheet Characteristics ATS22D47S6U Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product

More information

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW) Characteristics soft starter-ats22-control 220V-power 230V(110kW)/400...440V(220kW) Complementary Assembly style Function available Power supply voltage limits Main Range of product Altistart 22 Product

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact Characteristics variable speed drive ATV320-0.37kW - 380...500V - 3 phase - compact Main Range of product Product or component type Product specific application Device short name Format of the drive Product

More information

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O 8 173 TX-I/O niversal modules TXM1.8 TXM1.8-ML Two fully compatible versions: TXM1.8: 8 inputs/outputs with LED signal / fault indication TXM1.8-ML: As TXM1.8, but with additional local override facility

More information

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics. Characteristics soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Main Range of product Altistart 22 Product or component type Product destination Product specific application

More information

Model 2380 Rack-Mount Kit

Model 2380 Rack-Mount Kit Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 2380 Rack-Mount Kit Installation Instructions Introduction The Model 2380 Fixed Rack-Mount

More information

EQ5 SERIES Quick Start Guide for Constant Torque Applications

EQ5 SERIES Quick Start Guide for Constant Torque Applications EQ5 SERIES Quick Start Guide for Constant Torque Applications PN EQ5QSCT, Revision: 0.02, April 4 th 2009 EQ5 Drive Quick Start Guide for Constant Torque Applications Contents Page Introduction... 3 1.

More information

V E2B Snap-in I/O Module

V E2B Snap-in I/O Module V200-18-E2B Snap-in I/O Module The V200-18-E2B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously

More information

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVFF

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVFF ype VariFlex 3 RVFF RVFF AC variable speed drive for use with AC induction motors Sensorless vector control or V/F, SLV, PMSLV with space vector PWM mode Input voltage ranges: 3-ph 480VAC 50%/Hz (vector

More information

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Installation & Operating Instructions

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Installation & Operating Instructions AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP 200 480 Volt 1 & 3 Phase Installation & Operating Instructions IP20 Easy Start Up Guide AC Supply Connection Supply Voltage 3 Phase Units : Connect L1 L2

More information

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact Characteristics variable speed drive ATV320-0.75kW - 200...240V - 1 phase - compact Main Range of product Product or component type Product specific application Device short name Format of the drive Product

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Wide Modules Installation Guide UID-W1616R, UID-W1616T Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide

More information

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp)

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp) Characteristics soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp) Product availability : Stock - Normally stocked in distribution facility Price* : 1468.00 USD Main Range

More information

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3 Overview Safety notes 1 SITOP power supply Manual Description, device design, dimension drawing 2 Mounting/removal 3 Mounting position, mounting clearances 4 Installation 5 Technical data 6 Safety, approvals,

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

V E1B Snap-in I/O Module

V E1B Snap-in I/O Module V200-18-E1B Snap-in I/O Module The V200-18-E1B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

User Guide. IP20 & IP66 (NEMA 4X) AC Variable Speed Drive. Installation and Operating Instructions. 1 Quick Start Up kW (0.

User Guide. IP20 & IP66 (NEMA 4X) AC Variable Speed Drive. Installation and Operating Instructions. 1 Quick Start Up kW (0. 1 Quick Start Up User Guide IP20 & IP66 (NEMA 4X) AC Variable Speed Drive 0.37 22kW (0.5 30HP) 110 480V Installation and Operating Instructions 1 Quick Start Up 1 1. Quick Start Up... 4 1.1. Important

More information

Assembly and Commissioning Instructions AC Drive VersiDrive i... /Pro

Assembly and Commissioning Instructions AC Drive VersiDrive i... /Pro electronic Assembly and Commissioning Instructions AC Drive VersiDrive i... /Pro Quality is our Drive. VD i PRO IP20 Easy Start Up Guide AC Supply Connection Supply Voltage 3 Phase Units : Connect L1 L2

More information

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA

More information