Specifications. Inputs. Outputs. Recip Velocity. Signal. Front Panel LEDs OK LED. Input Impedance TX/RX LED. Sensor Compatibility.

Size: px
Start display at page:

Download "Specifications. Inputs. Outputs. Recip Velocity. Signal. Front Panel LEDs OK LED. Input Impedance TX/RX LED. Sensor Compatibility."

Transcription

1 3500/70M Recip Impulse/Velocity Monitor ently Nevada sset ondition Monitoring Description The 3500/70M Recip Impulse Velocity / Monitor is a 4-channel monitor that can be used as part of the reciprocating compressor solutions package for monitoring compressor crankcase and crosshead vibration. The monitor accepts input from seismic transducers, conditions the signal to derive various vibration measurements, and compares the conditioned signals with userprogrammable alarms. Each channel of the 3500/70M can be programmed using the 3500 Rack onfiguration Software to perform one of the following functions: Impulse Recip Recip Velocity Note: The monitor channels are programmed in pairs and perform up to two of these functions at a time. hannels 1 and 2 can perform one function, while hannels 3 and 4 perform another (or the same) function. The primary purposes of the 3500/70M monitor are to provide: 1. machinery protection by continuously comparing monitored parameters against configured alarm set points to drive alarms, and 2. essential machine information for both operations and maintenance personnel. Each channel, depending on configuration, typically conditions its input signal into various parameters called static values. Users can configure lert setpoints for each active static value and Danger set points for any two of the active static values. Rev. (11/08) Page 1 of 11

2 Specifications Specified at 25 (77 F), voltages referenced to monitor common unless specified otherwise. Inputs Signal Input Impedance Sensor ompatibility ccepts from 1 to 4 velocity or acceleration transducer signals. 10 k Ω ( Input), >1 MΩ (Velocity Input). Recip Velocity Outputs Front Panel LEDs OK LED TX/RX LED 3.94 mv/(mm/s) (100 mv/(in/s)), or user-selected mv/(mm/s) ( mv/(in/s). Indicates the 3500/70M is operating properly. Indicates the 3500/70M is communicating with other modules in the 3500 rack. Special Inhibit Power onsumption Sensitivity Velomitor Piezo-Velocity Sensor Velomitor X Piezo- Velocity Sensor Velomitor T Velocity Transducer ccelerometer Transducer ccelerometer Transducer ontact closure, 5 390µ typical. 7.7 watts, typical ypass LED Transducer Power Supply Voltage urrent Output Impedance Protection Indicates the 3500/70M is in ypass Mode. -22 Vdc minimum 40 m maximum; (15 m maximum on startup to guarantee no fold back) 20 Ω typical operating; 1000 Ω typical under fold back conditions. Foldback current 15.4 to 24.9 m Impulse Recip 10 mv/(m/s 2 ) (100 mv/g), or user-selected mv/(m/s 2 ) (5 115 mv/g). 10 mv/(m/s 2 ) (100 mv/g), or user-selected mv/(m/s 2 ) (5 115 mv/g). uffered Transducer Outputs: Output Impedance The front of each monitor has one coaxial connector for each channel. 550 Ω typical. Rev. (11/08) Page 2 of 11

3 Protection Not OK Filter Each connector is short-circuit protected. -3 d at 2400 z, 1-pole, Low- Pass Recorder: Static values +4 to +20 m proportional to monitor full-scale. The user selects one static data value from each channel to be used for that channel s recorder value. Filter Quality igh-pass Smoothing filter, 8-revolution average value. Voltage ompliance 4-pole (80 d per decade, 24 d +12 Vdc maximum. Low-Pass Load Resistance Resolution Update rate ccuracy 600 Ω maximum µ maximum <100 msec. orner selection: 4-pole (80 d per decade, 24 d Peak 3 db corner RMS 3 d corner igh-pass z z Low-Pass z z Signal onditioning Impulse ccuracy and start Within ±0.05 m, ±0.14 m over temperature range. Within ± 0.33% of full-scale typical, ± 1% maximum. Exclusive of filters. Recip ccuracy Frequency Response ias Filter Not OK Filter Within ± 0.33% of full-scale typical, ± 1% maximum. Exclusive of filters. -3 d at 0.01 z, 1-pole, Low-Pass and duration Frequency Response ias Filter 0 to 359, 1 resolution. 1 to 360, 1 resolution. -3 d at 0.01 z, 1-pole, Low-Pass Peak static values RMS static values -3 d at 2400 z, 1-pole, Low- Pass -3 d at 0.3 z, 1-pole, Low-Pass -3 d at 0.1 z, 1-pole, Low-Pass Rev. (11/08) Page 3 of 11

4 Filter Quality igh-pass Low-Pass orner selection igh-pass Low-Pass Recip Velocity ccuracy Velomitor Frequency Response ias filter Not OK filter Integration filter 4-pole (80 d per decade, 24 d 4-pole (80 d per decade, 24 d Peak 3 db corner Integrate and/or RMS 3 d corner z z z z Within ± 0.33% of full-scale typical, ± 1% maximum. Exclusive of filters. dditional accuracy degradation occurs when full scale signal levels are low: Full Scale 0-0.5: ±3% Typical Full Scale 0-1.0: ±2% Typical Full Scale 0-2.0: ±1% Typical -3d at 0.09 z, 1-pole, Low Pass -3 d at 2400 z, 1-pole, Low Pass -3 db at 0.34 z, 1-pole, Low-Pass RMS static values Peak static values 1X & 2X Vector Filter Filter Qualityigh- Pass Low-Pass: orner selection: -3 d at 0.1 z, 1-pole, Low-Pass -3 d at 0.3 z, 1-pole, Low-Pass onstant Q filter with bandwidth = ± 3% running speed (Q=16.7). 4-pole (80 d per decade, 24 d 2-pole (40 d per decade, 12 d Non-RMS 3 d corner RMS 3 d corner igh-pass z z z (T) Low-Pass z z larms larm Set points: Users can set lert levels for each value measured by the monitor. In addition, users can set Danger set points for any two of the values measured by the monitor. ll alarm set points are set using the 3500 Rack onfiguration Software. larms are adjustable and can normally be set from 0 to 100% of full-scale for each measured value. The exception is when the full-scale range exceeds the range of the transducer. In this case, the software will limite the setpoint to the range of the transducer. ccuracy of alarms is within 0.13% of the desired value. larm Time Delays: larm delays can be programmed using software, and can be set as follows for all channel types: Rev. (11/08) Page 4 of 11

5 lert Danger Static Values Impulse Recip Recip Velocity From 1 to 60 seconds in 1 second intervals. From 1 to 60 seconds in 0.5 second intervals or 0.1 seconds. Static values are measurements used to monitor the machine. The Recip Impulse / Velocity Monitor returns static values from one of the following channel types: Direct, ias Voltage, six (6) useradjustable crank angle bands with peak or RMS acceleration in the band. Direct, 1X mplitude, 2X mplitude (defined as: RMS or peak acceleration or velocity) and 1X Phase, 2X Phase and ias Voltage. Direct, 1X mplitude, 2X mplitude (defined as: RMS or peak velocity or peak-to-peak displacement),and 1X Phase, 2X Phase and ias Voltage Note: ias Voltage contains no information about the condition of the machinery being monitored but is provided only for monitor system diagnostics. arrier Parameters Proximitor arrier ircuit Parameters The following parameters apply for both S-NRTL/ and ENELE approvals. Vmax () = V () = V hannel Parameters (Entity) Seismic arrier ircuit Parameters hannel Parameters (Entity) Environmental Limits Operating Temperature With Internal/External Termination I/O Module With Internal arrier I/O Module (Internal Termination): Storage Temperature umidity () = 2.82 m Rmin () = Ω () = 4985 Ω Vmax = 28.0 V Imax = m Rmin () = Ω () = 4985 Ω Vmax () = V Imax () = 91.8 m Rmin () = 297 Ω Vmax = V Imax = 91.8 m Rmin () = 297 Ω -30 to +65 (-22 F to +150 F) 0 to +65 (32 F to +150 F) -40 to +85 (-40 F to +185 F). 95%, non-condensing. Imax () = m Rev. (11/08) Page 5 of 11

6 E Mark Directives EM Directives: ertificate of onformity: EN Radiated Emissions onducted Emissions EN Electrostatic Discharge Radiated Susceptibility EN 55011, lass EN 55011, lass EN , riteria ENV 50140, riteria E Mark Low Voltage Directives: ertificate of onformity: EN : Safety Requirements azardous rea pprovals S/NRTL/ pproval Option (01) ertification Number lass I, Div 2 Groups,,, D Ta = -30 to +65 (-22 F to +150 F) S (LR 26744) onducted Susceptibility Note: When used with Internal arrier I/O Module, refer to specification sheet Electrical Fast Transient Surge apability Magnetic Field ENV 50141, riteria EN , riteria EN , riteria Physical Monitor Module (Main oard) Dimensions (eight x Width x Depth): for approvals information mm x 24.4 mm x mm (9.50 in x 0.96 in x 9.52 in). EN , riteria Weight: Power Supply Dip EN , riteria I/O Modules (non-barrier) 0.91 kg (2.0 lb.). Radio Telephone ENV 50204, riteria Dimensions (eight x Width x Depth): mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in). Weight: 0.20 kg (0.44 lb.). Rev. (11/08) Page 6 of 11

7 I/O Modules (barrier) Dimensions (eight x Width x Depth): Weight: mm x 24.4 mm x mm (9.50 in x 0.96 in x 6.42 in) kg (1.01 lb.). Rack Space Requirements System 1 T Software Firmware: 3500/70M Firmware 3500/22M TDI Firmware Version 5.10 Version 2.30 Version 1.30 Monitor Module: I/O Modules: 1 full-height front slot. 1 full-height rear slot. Ordering onsiderations General External Termination locks cannot be used with Internal Termination I/O Modules. When ordering I/O Modules with External Terminations, the External Termination locks and ables must be ordered separately. The 3500 Internal arrier specification sheet (part number ) should be consulted if the Internal arrier Option is selected. Software / Firmware ompatibility The 3500/70M Module requires the following (or later) firmware and software revisions: Software: 3500/01 onfiguration Software 3500/02 Data cquisition Software 3500/03 Operator Display Software Version 3.70 Version 2.50 Version 1.50 Ordering Information Recip Impulse/Velocity Monitor 3500/70-XX-XX : I/O Option 0 1 Prox/Velom I/O Module with Internal Terminations 0 2 Prox/Velom I/O Module with External Terminations 0 3 Internal arrier, 4 accelerometers 0 4 Internal arrier, 2 accelerometers, 2 Velomitors 0 5 Internal arrier, 4 Velomitors : gency pproval Option 00 None 01 S/NRTL/ External Termination locks Recorder External Termination lock (Euro Style connectors). Recorder External Termination lock (Terminal Strip connectors). Proximitor/Velomitor External Termination lock (Euro Style connectors). Proximitor/Velomitor External Termination lock (Terminal Strip connectors). Rev. (11/08) Page 7 of 11

8 ables 3500 Transducer (XDR) Signal to External Termination (ET) lock able XXXX-XX : able Length feet (1.5 metres) feet (2.1 metres) feet (3 metres) feet (7.5 metres) feet (15 metres) feet (30.5 metres) : ssembly Instructions 0 1 Not ssembled 0 2 ssembled 3500 Recorder Output to External Termination (ET) lock able XXXX-XX : able Length feet (1.5 metres) feet (2.1 metres) feet (3 metres) feet (7.5 metres) feet (15 metres) feet (30.5 metres) : ssembly Instructions 0 1 Not ssembled 0 2 ssembled Spares I/O Module with Internal arriers (Internal Terminations) (4 x Prox/ccel). I/O Module with Internal arriers (Internal Terminations) (2 x Prox/ccel + 2 x Velomitor). I/O Module with Internal arriers (Internal Terminations) (4 x Velomitor). Prox/Velom I/O Module with Internal Terminations. Prox/Velom I/O Module with External Terminations. 3500/70M Prox/Velom I/O Module ten-pin connector shunt. Internal I/O Module connector header, Euro Style, 8 pin. Used on I/O modules and /70M Impulse/Velocity Monitor. 3500/70M Recip Impulse/Velocity Monitor Manual Internal I/O Module connector header, Euro Style, 10 pin. Used on I/O modules , Internal I/O Module connector header, Euro Style, 12 pin Rev. (11/08) Page 8 of 11

9 Graphs and Figures 1. Status LEDs 2. uffered Transducer Outputs 3. Prox/Velom I/O Module, Internal Terminations, Prox/Velom I/O Module, External Terminations, Figure 1: Front and rear view of the Recip Impulse / Velocity Monitor Rev. (11/08) Page 9 of 11

10 RRIER PROXIMITOR I/O MODULE RRIER PROX/SEISMI I/O MODULE RRIER SEISMI I/O MODULE 1 2 SLD SLD 1 2 SLD SLD 1 2 SLD SLD I.S. IRUITS I.S. IRUITS I.S. IRUITS SEE SIDE PNEL SEE SIDE PNEL SEE SIDE PNEL 3 4 SLD SLD 3 4 SLD SLD 3 4 SLD SLD IN RET RE1 RE2 RE3 RE4 IN RET RE1 RE2 RE3 RE4 IN RET RE1 RE2 RE3 RE4 SIELD SIELD SIELD arrier I/O module for connecting four ccelerometer sensors arrier I/O module for connecting two ccelerometer sensors and two Velomitor sensors arrier I/O module for connecting four Velomitor sensors Figure 2: arrier I/O Modules for the ImpulseRecip Impulse / Velocity Monitor Rev. (11/08) Page 10 of 11

11 opyright ently Nevada LL ently Parkway South, Minden, Nevada US Phone: Fax: ll rights reserved. ently Nevada, Proximitor, System 1, and Velomitor are trademarks of General Electric ompany. Rev. (11/08) Page 11 of 11

3500/77M Recip Cylinder Pressure Monitor

3500/77M Recip Cylinder Pressure Monitor 3500/77M Recip Cylinder Pressure Monitor Bently Nevada Asset Condition Monitoring Description The 3500/77M Recip Cylinder Pressure Monitor is a 4-channel monitor that accepts input from Bently Nevada approved

More information

3500/45 Position Monitor

3500/45 Position Monitor 3500/45 Position Monitor Bently Nevada Asset Condition Monitoring Description The 3500/45 Position Monitor is a 4-channel monitor that accepts input from proximity transducers, Rotary Position Transducers

More information

3500/53 Electronic Overspeed Detection System

3500/53 Electronic Overspeed Detection System 3500/53 Electronic Overspeed Detection System Description The Bently Nevada Electronic Overspeed Detection System for the 3500 Series Machinery Detection System provides a highly reliable, fast response,

More information

3500/77M Recip Cylinder Pressure Monitor

3500/77M Recip Cylinder Pressure Monitor 3500/77M Recip Cylinder Pressure Monitor Product Datasheet Bently Nevada* Asset Condition Monitoring Description The 3500/77M Recip Cylinder Pressure Monitor is a 4-channel monitor that accepts input from

More information

3500/15 Power Supply. Description

3500/15 Power Supply. Description 3500/15 Power Supply Description The 3500 Power Supplies are half-height modules and must be installed in the specially designed slots on the left side of the rack. The 3500 rack can contain one or two

More information

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring 3500/15 Power Supply Bently Nevada* Asset Condition Monitoring Description The 3500 Power Supplies are half-height modules and must be installed in the specially designed slots on the left side of the

More information

3500 Internal Barriers Product Datasheet Bently Nevada* Asset Condition Monitoring

3500 Internal Barriers Product Datasheet Bently Nevada* Asset Condition Monitoring GE Measurement & Control 3500 Internal Barriers Product Datasheet Bently Nevada* Asset Condition Monitoring Description 3500 Internal Barriers are intrinsically safe interfaces that provide explosion protection

More information

3500/65 16-Channel Temperature Monitor

3500/65 16-Channel Temperature Monitor 3500/65 16-Channel Temperature Monitor Bently Nevada* Asset Condition Monitoring Description The 3500/65 monitor provides 16 channels of temperature monitoring and accepts both resistance temperature detector

More information

3500/45E Position Monitor

3500/45E Position Monitor 3500/45E Position Monitor Bently Nevada* Asset Condition Monitoring Description The 3500/45E Position Monitor is a 4-channel monitor that accepts input from proximity transducers, Rotary Position Transducers

More information

3500/50E Tachometer Module

3500/50E Tachometer Module 3500/50E Tachometer Module Bently Nevada* Asset Condition Monitoring Description The 3500/50E Tachometer Module is a 2-channel module that accepts input from proximity probes or magnetic pickups (except

More information

3500/92 Communication Gateway

3500/92 Communication Gateway 3500/92 Communication Gateway Description The 3500/92 Communication Gateway module provides extensive communication capabilities of all rack monitored values and statuses for integration with process control

More information

3500/25 Enhanced Keyphasor*Module

3500/25 Enhanced Keyphasor*Module 3500/25 Enhanced Keyphasor*Module Product Datasheet Bently Nevada* Asset Condition Monitoring Description The 3500/25 Enhanced Keyphasor Module is a half-height, two-channel module used to provide Keyphasor

More information

3500/23E Transient Data Interface

3500/23E Transient Data Interface 3500/23E Transient Data Interface Bently Nevada* Asset Condition Monitoring Description The 3500/23E Transient Data Interface (TDI) is the interface between the 3500 ENCORE monitoring system and GE s System

More information

3500/33 16-Channel Relay Module Bently Nevada* Asset Condition Monitoring

3500/33 16-Channel Relay Module Bently Nevada* Asset Condition Monitoring 3500/33 16-Channel Relay Module Bently Nevada* Asset Condition Monitoring Description The 16-Channel Relay Module is a full-height module that provides 16 relay outputs. Any number of 16-Channel Relay

More information

3500/32M 4-Channel Relay Module

3500/32M 4-Channel Relay Module 3500/32M 4-Channel Relay Module Bently Nevada* Asset Condition Monitoring Description The 4-Channel Relay Module is a full-height module that provides four relay outputs. Any number of 4-Channel Relay

More information

3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring

3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring 3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring Description The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring system and GE s System 1* machinery

More information

3500/22M Transient Data Interface

3500/22M Transient Data Interface Specifications and Ordering Information 3500/22M Transient Data Interface Description The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring system and Bently Nevada s System

More information

3500/23E Transient Data Interface

3500/23E Transient Data Interface 3500/23E Transient Data Interface Bently Nevada* Asset Condition Monitoring Description The 3500/23E Transient Data Interface (TDI) is the interface between the 3500 ENCORE monitoring system and GE s System

More information

3500/95 System Integrated PC Display Bently Nevada* Asset Condition Monitoring

3500/95 System Integrated PC Display Bently Nevada* Asset Condition Monitoring 3500/95 System Integrated PC Display Bently Nevada* Asset Condition Monitoring Description The 3500/95 System Integrated PC Display provides local or remote visual indication of all 3500 Machinery Protection

More information

9200, Seismoprobe

9200, Seismoprobe 9200, 74712 Seismoprobe Description Bently Nevada Seismoprobe Velocity Transducer Systems are designed to measure absolute (relative to free space) bearing housing, casing, or structural vibration. The

More information

and High Temperature Velomitor * System

and High Temperature Velomitor * System 330750 and 330752 High Temperature Velomitor * System Bently Nevada* Asset Condition Monitoring Description The standard 330500 Velomitor* Piezo-velocity Sensor has a limited temperature range it can be

More information

Velomitor * Piezo-velocity Sensor

Velomitor * Piezo-velocity Sensor Velomitor * Piezo-velocity Sensor Bently Nevada* Asset Condition Monitoring Description Velomitor * Piezo-velocity Sensors measure absolute (relative to free space) bearing housing, casing, or structural

More information

1900/65A General Purpose Equipment Monitor

1900/65A General Purpose Equipment Monitor 1900/65A General Purpose Equipment Monitor Bently Nevada* Asset Condition Monitoring Description The 1900/65A General Purpose Equipment Monitor is designed to continuously monitor and protect equipment

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

3500/22M Transient Data Interface Module

3500/22M Transient Data Interface Module 3500/22M Transient Data Interface Module Product Datasheet Bently Nevada* Asset Condition Monitoring Description The 3500/22M Transient Data Interface (TDI) is the interface between the 3500 monitoring

More information

1701/05 FieldMonitor* Terminal Base Bently Nevada* Asset Condition Monitoring

1701/05 FieldMonitor* Terminal Base Bently Nevada* Asset Condition Monitoring 70/05 FieldMonitor* Terminal Base Bently Nevada* Asset Condition Monitoring Description The 70/05 Terminal Base is the mounting platform for the FieldMonitor* system for applications where transducers

More information

Vibration Transducer Interface

Vibration Transducer Interface Vibration Transducer Interface Description The Vibration Transducer Interface (VTI) is a galvanic isolation solution provided by GE s Bently Nevada product line. With the use of galvanic isolation, an

More information

Description. Specifications

Description. Specifications R Specifications and Ordering Information 1701/15 FieldMonitor Proximitor Input Monitor for Radial Vibration and Thrust Position The 1701/15 FieldMonitor Proximitor Input Monitor is a 2-channel device

More information

9200, Seismoprobe* Velocity Transducers

9200, Seismoprobe* Velocity Transducers 9200, 74712 Seismoprobe* Velocity Transducers Product Datasheet Bently Nevada* Asset Condition Monitoring Description Bently Nevada* Seismoprobe Velocity Transducer Systems are designed to measure absolute

More information

9200, Seismoprobe * Bently Nevada* Asset Condition Monitoring

9200, Seismoprobe * Bently Nevada* Asset Condition Monitoring 9200, 74712 Seismoprobe * Bently Nevada* Asset Condition Monitoring Description Bently Nevada Seismoprobe * Velocity Transducer Systems are designed to measure absolute (relative to free space) bearing

More information

2300 Vibration Monitors

2300 Vibration Monitors 2300 Vibration Monitors Product Datasheet Bently Nevada* Asset Condition Monitoring Description The 2300 Vibration Monitors provide cost-effective continuous vibration monitoring and protection capabilities

More information

Description. Specifications and Ordering Information 9200, 74712, Seismoprobe Velocity Transducer System

Description. Specifications and Ordering Information 9200, 74712, Seismoprobe Velocity Transducer System R Specifications and Ordering Information 9200, 74712, 47633 Seismoprobe Velocity Transducer System Description Bently Nevada Seismoprobe Velocity Transducer systems are designed to measure absolute (relative

More information

and High Temperature Velomitor * System

and High Temperature Velomitor * System 330750 and 330752 High Temperature Velomitor * System Product Datasheet Bently Nevada* Asset Condition Monitoring Description The standard 330500 Velomitor* Piezo-velocity Sensor has a limited temperature

More information

Velomitor* CT Velocity Transducer

Velomitor* CT Velocity Transducer 190501 Velomitor* CT Velocity Transducer Product Datasheet Bently Nevada* Asset Condition Monitoring Description The Velomitor CT Velocity Transducer is a low-frequency version of our standard Velomitor

More information

Operation and Maintenance Manual. 3500/42 Proximitor/Seismic Monitor Module. Part Number Rev. H (07/07)

Operation and Maintenance Manual. 3500/42 Proximitor/Seismic Monitor Module. Part Number Rev. H (07/07) Operation and Maintenance Manual 3500/42 Proximitor/Seismic Monitor Module Part Number 129773-01 Rev. H (07/07) 3500/42 Proximitor/Seismic Monitor Module Operation and Maintenance Manual Copyright 1995

More information

Description. Improved Startup/Shutdown Data Collection: New Ethernet Link to Data Manager* 2000 computers. View Transient Plots during machine SU/SD

Description. Improved Startup/Shutdown Data Collection: New Ethernet Link to Data Manager* 2000 computers. View Transient Plots during machine SU/SD TDXnet* Bently Nevada* Asset Condition Monitoring Description The TDXnet Communications Processor provides the interface between our compatible (see note) machinery protection systems and our on-line machinery

More information

2300 Vibration Monitors

2300 Vibration Monitors 2300 Vibration Monitors Product Datasheet Bently Nevada* Asset Condition Monitoring Description The 2300 Vibration Monitors provide cost-effective continuous vibration monitoring and protection capabilities

More information

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications MSR 2400R Rugged Power System for Military and Heavy Duty Applications 2400 W modular power system Power supply or battery charging systems Parallel n+1 connection, up to 90A Series connection, up to 360VDC

More information

Bently Nevada 60M100 Monitor Bently Nevada* Asset Condition Monitoring

Bently Nevada 60M100 Monitor Bently Nevada* Asset Condition Monitoring Bently Nevada 60M100 Monitor Bently Nevada* Asset Condition Monitoring Description The 60M100 Condition Monitoring System provides continuous on-line monitoring of Wind Turbine machine trains using sophisticated

More information

Protection Cards for AMS 6500 Classic Systems

Protection Cards for AMS 6500 Classic Systems Protection Cards for AMS 6500 Classic Systems A6740-10 16-Channel Output Relay Module A6740-12 16-Channel Output Relay Module A6125 Case Piezoelectric Vibration Monitor A6120 Case Seismic Vibration Monitor

More information

15-80 ka surge protection Hz line frequency <.5 ns response time Available in units noted from 15-1,200 Amps

15-80 ka surge protection Hz line frequency <.5 ns response time Available in units noted from 15-1,200 Amps Series Filters with Transient Voltage Surge Suppression Islatrol Series Two stage, high-frequency noise filter and high-energy current diverter available from 5 mp single phase to 1200 mp three phase.

More information

Description. System Event List Alarm Event List All module and channel data Current alarm data (quick view) Nine custom display options.

Description. System Event List Alarm Event List All module and channel data Current alarm data (quick view) Nine custom display options. 3500/94M VGA Display Product Datasheet Bently Nevada* Asset Condition Monitoring The 3500/94M VGA Display uses a standard color VGA monitor with Touch Screen technology to display 3500 data. This product

More information

PART NUMBER REVISION E, 3300 SYSTEM COMPATIBILITY GUIDE

PART NUMBER REVISION E, 3300 SYSTEM COMPATIBILITY GUIDE PART NUMBER 104003-01 REVISION E, 3300 SYSTEM COMPATIBILITY GUIDE 104003-01 3300 System Compatibility Guide NOTICE READ THE FOLLOWING BEFORE INSTALLING OR OPERATING EQUIPMENT Bently Nevada Corporation

More information

3500/08 Diagnostics Access Panel

3500/08 Diagnostics Access Panel Part number 136275-01 Revision A, June 2005 3500/08 Diagnostics Access Panel Operation and Maintenance Manual Copyright 1997 Bently Nevada LLC All Rights Reserved. The information contained in this document

More information

991 Thrust Transmitter Bently Nevada* Asset Condition Monitoring

991 Thrust Transmitter Bently Nevada* Asset Condition Monitoring 991 Thrust Transmitter Bently Nevada* Asset Condition Monitoring Description The 991 Thrust Transmitter is intended primarily for the original equipment manufacturers (OEMs) of centrifugal air compressors

More information

3500 ENCORE System Overview Bently Nevada* Asset Condition Monitoring

3500 ENCORE System Overview Bently Nevada* Asset Condition Monitoring 3500 ENCORE System Overview Bently Nevada* Asset Condition Monitoring Description The 3500 ENCORE System provides continuous, online monitoring suitable for machinery protection applications and is designed

More information

Valve and Case Expansion Monitor Specifications

Valve and Case Expansion Monitor Specifications Valve and Case Expansion Monitor Specifications The Valve and Case Expansion Monitor is designed for high reliability for the plant s most critical rotating machinery. This 1-slot monitor is used together

More information

DTM Distributed Transmitter Monitor

DTM Distributed Transmitter Monitor DTM20 Seismic Vibration Distributed Transmitter-Monitor (Acceleration, Velocity, Displacement) The DTM20 distributed Seismic vibration transmitter-monitor provides a simple and cost-effective solution

More information

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES Two cards providing 8 channels of temperature and process monitoring for VM 600 systems 8 channels of software selectable

More information

H-series (Rectifier Module)

H-series (Rectifier Module) H-series (Rectifier Module) Overview: The rectifier modules provide unprecedented power density and power levels in a true plug and play format. With a wide range of available voltages, power ratings,

More information

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS Installation Manual 1180 METRIX Experience Value 8824 Fallbrook Dr. Houston, TX 77064, USA Tel: 1-281-940-1802 After Hours Technical Assistance: 1-713-702-8805

More information

YTM Series Digital-Transmitter-Monitor

YTM Series Digital-Transmitter-Monitor YTM101 Seismic Vibration Digital-Transmitter-Monitor (Acceleration, Velocity, Displacement) The YTM101 Seismic vibration transmitter-monitor provides a simple and cost-effective solution for monitoring

More information

Isolated Process Current Input with Loop Power 7B35

Isolated Process Current Input with Loop Power 7B35 Isolated Process Current Input with Loop Power 7B35 FEATURES Single-channel signal conditioning current input module that interfaces with two-wire transmitters. Module provides a precision output of either

More information

21000,24701 Proximity Probe Housing Assemblies Bently Nevada Asset Condition Monitoring

21000,24701 Proximity Probe Housing Assemblies Bently Nevada Asset Condition Monitoring 21000,24701 Proximity Probe Housing Assemblies Bently Nevada Asset Condition Monitoring Description Proximity Probe Housing Assemblies Bently Nevada offers two all-metal Proximity Probe Housing Assemblies

More information

RT4F-48V/50A-WAC RECTIFIER

RT4F-48V/50A-WAC RECTIFIER The RT4F-48V/50A-WAC is a switched mode rectifier (SMR) module designed to provide up to 58A of output current into a 48V nominal system, over a wide range of AC input voltage. This rectifier has been

More information

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Voltage Input 7B31 FEATURES Interfaces, amplifies, and filters unipolar and bipolar voltage inputs. Module provides a precision output of either +1 V to +5 V or 0 V to +10 V, linear with temperature.

More information

RT12-240V/2.4kW Rectifier Specification

RT12-240V/2.4kW Rectifier Specification The RT12-240V/2.4kW is a switched mode rectifier (SMR) module that delivers up to 2.4kW of output power (and up to 11A output current) into a 240V nominal DC system. The RT12 suits AC supply voltages between

More information

991 Thrust Transmitter Bently Nevada* Asset Condition Monitoring

991 Thrust Transmitter Bently Nevada* Asset Condition Monitoring 991 Thrust Transmitter Bently Nevada* Asset Condition Monitoring Description The 991 Thrust Transmitter is intended primarily for the original equipment manufacturers (OEMs) of centrifugal air compressors

More information

GEN series G070A. Data sheet. Torque/RPM adapter. Special features

GEN series G070A. Data sheet. Torque/RPM adapter. Special features GEN series G070A Torque/RPM adapter Data sheet Special features - Connect up to two torque transducers - Connect to T12/T40B using standard cables - RS422 differential input signals for highest immunity

More information

RT4F-120V/20A-WAC RECTIFIER

RT4F-120V/20A-WAC RECTIFIER The RT4F-120V/20A-WAC is a switched mode rectifier/charger module designed to provide up to 20A of output current into a 120V nominal system. This charger has been designed for use in conjunction with

More information

RT4B-110V/12A RECTIFIER

RT4B-110V/12A RECTIFIER The RT4B-110V/12A is a switched mode rectifier (SMR) module designed to provide up to 12A of output current into a 110V nominal system. It can be used with or without a cooling fan. With a fan it runs

More information

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Voltage or Current Input 7B30 FEATURES Interfaces, amplifies and filters unipolar and bipolar millivolt and voltage inputs. Provides a protected precision output of either +1 V to +5 V or 0 V

More information

Operation and Maintenance Manual Bently Nevada Asset Condition Monitoring. 3500/25 Enhanced Keyphasor Module. Part Number Rev.

Operation and Maintenance Manual Bently Nevada Asset Condition Monitoring. 3500/25 Enhanced Keyphasor Module. Part Number Rev. Operation and Maintenance Manual Bently Nevada Asset Condition Monitoring 3500/25 Enhanced Keyphasor Module Part Number 129770-01 Rev. N (03/08) 3500/25 Enhanced Keyphasor Module Operation and Maintenance

More information

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Process Current Input 7B32 FEATURES Interfaces, amplifies and filters a process-current input. Module provides a precision output of either +1 V to +5 V or 0 V to +10 V, linear with temperature.

More information

Electronic Vibration Switch PMC/BETA 440 & 450

Electronic Vibration Switch PMC/BETA 440 & 450 PMC/BETA & Features Built-in alarm time delay Reduce false triggering Velocity triggering provides protection at all frequencies Displacement triggering available for low speed machinery Sensitivity is

More information

Isolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Process Current Output 7B39 FEATURES Interfaces, isolates and filters a 0 V to + 10 V or +1 V to +5 V input signal. Provides an isolated process current output of 0 ma to 20 ma or 4 ma to 20

More information

ICS Regent. Monitored Digital Input Modules 24 VDC (T3411) PD-6031

ICS Regent. Monitored Digital Input Modules 24 VDC (T3411) PD-6031 ICS Regent PD-6031 Monitored Digital Input Modules 24 VDC (T3411) Issue 1, March, 06 Monitored digital input modules provide input sensing for 16 field input devices. With a line monitor device installed

More information

Relion 611 series. 611 series Type Test Certificate

Relion 611 series. 611 series Type Test Certificate Relion 611 series 611 series Document ID: 1MRS757466 Issued: 2016-02-22 Revision: B Product version: 2.0 Copyright 2016 ABB. All rights reserved Table of contents Table of contents Section 1 Section

More information

Datasheet. Overview. Temperature Monitoring Module

Datasheet. Overview. Temperature Monitoring Module Datasheet Temperature Monitoring Module Overview The Temperature Monitoring Module (TMM) accepts from one to six 2-, 3-, and 4-wire RTDs and/or thermocouples (both grounded and ungrounded tip) in any combination

More information

Model 7705 Control Module

Model 7705 Control Module www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be

More information

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation

More information

3300 RAM and NSv Proximity Transducer System

3300 RAM and NSv Proximity Transducer System 33 RAM and NSv Proximity Transducer System Description The 33 RAM and NSv Proximity Transducer system is intended for centrifugal air compressors, refrigeration compressors, process gas compressors and

More information

REVISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 13/12/08 Specification Release 13/12/08 S. Sadot A1 13/02/09

REVISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 13/12/08 Specification Release 13/12/08 S. Sadot A1 13/02/09 Electrical Specification for: CPCI - 6U - DC - 600W Telkoor Part Number: 900-6113-0000 SCALE RELEASE DATE 13/12/08 SHEET 1 OF 7 REVISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective

More information

CSI 9330 Vibration Transmitter

CSI 9330 Vibration Transmitter O-9330-070110 C 9330 Vibration Transmitter Continuously monitors critical machinery in process applications and other industrial environments Interfaces with existing alarm, control and monitoring systems

More information

IOC4T. Input / output card. » From the Vibro-Meter product line» Signal interface card with 6 channels, for the MPC4 machinery protection card

IOC4T. Input / output card. » From the Vibro-Meter product line» Signal interface card with 6 channels, for the MPC4 machinery protection card FEATURES» From the Vibro-Meter product line» Signal interface card with 6 channels, for the MPC4 machinery protection card» Screw terminal strip (48 terminals) for all input / output connections» Contains

More information

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1 Manual PCD3.C90 Revision History Date Modification Asked by: Version 14.09.09 E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1 22.09.09 Added E/A Bus Connector PCD3.K116 Müller.R 1.2 06.01.10

More information

KEPCO GIVES YOU ZERO-UP PROGRAMMABILITY IN AN AFFORDABLE POWER MODULE

KEPCO GIVES YOU ZERO-UP PROGRAMMABILITY IN AN AFFORDABLE POWER MODULE 146-1915 More than switch mode boxes with wide-range a-c/d-c input power factor correction and current-share capacity... KEPCO GIVES YOU ZERO-UP PROGRAMMABILITY IN AN AFFORDABLE POWER MODULE RKW 300W 92

More information

200150, & Accelerometers Bently Nevada* Asset Condition Monitoring

200150, & Accelerometers Bently Nevada* Asset Condition Monitoring 200150, 200155 & 200157 Accelerometers Bently Nevada* Asset Condition Monitoring Description The 20015x Accelerometers are general purpose, wide frequency, case-mounted seismic transducers designed for

More information

GSP750 Series. 750 Watts. AC-DC Power Supplies. Models & Ratings. Input

GSP750 Series. 750 Watts.   AC-DC Power Supplies. Models & Ratings. Input C-DC Power Supplies 750 Watts 900 W Peak Power Rating for 100 ms Universal 80-264 VC Input IT & Medical Safety pprovals 1.0 W Standby Power -40 C to +70 C Operation Remote On/Off 5 V/3 Standby Output 3

More information

(877) CPCI-3U Series. Input Voltage Range AC Input. Input Voltage Range 48VDC Input. Input Voltage Range 24/28VDC Input

(877) CPCI-3U Series. Input Voltage Range AC Input. Input Voltage Range 48VDC Input. Input Voltage Range 24/28VDC Input (877) 634-0982 www.digipwr.com 200 300 Watt Compact PCI Power Supply Product Specification Universal AC Input with PFC, 48VDC or 24/28VDC Input Key Product Features Up to 3U Cabinet Environmentally Rugged

More information

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Voltage Input 3B30 / 3B31 FEATURES Interfaces, amplifies, & filtersanalog input voltages. Narrow-bandwidth (3Hz) single-channel single conditioning. Module provides simultaneous precision voltage

More information

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017 ICS Regent PD-6017 Relay Output Modules Low Power and High Power (T3446L and T3446H) Issue 1, March, 06 Relay output modules provide control of eight user output loads. Two types of relay output modules

More information

PRODUCT DESCRIPTION. Vertically cooled 2RU rectifiers with wide range of output modules available.

PRODUCT DESCRIPTION. Vertically cooled 2RU rectifiers with wide range of output modules available. High Efficiency Module Eltek V-series rectifiers provide industry-leading efficiency in a 2 RU footprint. Reliability, scalability, and hot-swap capability make for optimal system design and cost-effective

More information

RT7-48V/6kW Specification

RT7-48V/6kW Specification The RT7-48V/6kW is a 3 phase, active power factor corrected, switched mode rectifier (SMR) module designed to provide up to 6kW of output power (100A nominal) into a 48V nominal system. This rectifier

More information

Line Impedance Stabilization Network (LISN)

Line Impedance Stabilization Network (LISN) Model 3816/2 Line Impedance Stabilization Network (LISN) User Manual ETS-Lindgren Inc. reserves the right to make changes to any product described herein in order to improve function, design, or for any

More information

Revision Issue Date Pages Affected A0 08/14/2006 ALL Modify From CP-8120 Specification Rev:ED by Customer given.

Revision Issue Date Pages Affected A0 08/14/2006 ALL Modify From CP-8120 Specification Rev:ED by Customer given. REVISION HISTORY Revision Issue Date Pages Affected Description A0 08/14/2006 ALL Modify From CP-8120 Specification Rev:ED by Customer given. 11/06/2006 ALL Rev:A0 CR1 Rescription CUST PN:40012100W A 40012100W

More information

CPCI - 6U - AC - 600W

CPCI - 6U - AC - 600W Electrical Specification for: CPCI - 6U - AC - 600W Telkoor Part Number: 900-6115-0000 SCALE RELEASE DATE 13/12/08 SHEET 1 OF 7 REVISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective

More information

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES Interfaces, amplifies, protects& filters wide-bandwidth (h0 khz) single-channel analog voltage inputs. Module provides simultaneous precision voltage

More information

TM3DI16 module TM3-16 inputs

TM3DI16 module TM3-16 inputs Characteristics module TM3-16 inputs Main Range of product Product or component type Range compatibility Jun 30, 2018 Modicon TM3 Discrete input module Modicon M241 Modicon M251 Modicon M221 Discrete input

More information

ECF40 Series. 40 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

ECF40 Series. 40 Watts.   AC-DC Power Supplies. Models & Ratings. Mechanical Details 40 Watts 40 W Convection Rating 1.5 by 3 Footprint Low 1.1 Profile High Efficiency Medical and ITE pprovals High Power Density Less than 0.15 W No Load Input Power 3 Year Warranty The ECF40 series is designed

More information

Isolated Current Output 5B39 FEATURES APPLICATIONS PRODUCT OVERVIEW

Isolated Current Output 5B39 FEATURES APPLICATIONS PRODUCT OVERVIEW Isolated Current Output 5B39 FEATURES Converts a High-level analog input voltage into a floating proportional output current. Output current of 4 to 20 ma or 0 to 20 ma across loads from 0Ω to 750Ω. High

More information

CPCI - 6U - DC - 350W

CPCI - 6U - DC - 350W Electrical Specification for: CPCI - 6U - DC - 350W Telkoor Part Number: 900-6001-0000 Approvals Name Date Written by: S. Sadot 13/3/08 Engineering: M. Heller 13/3/08 Sales & Marketing: B. Steinfeld 13/3/08

More information

4-Pole Relay. 2 Coil. [V] Hz A1 A2 60 Hz A24 A1 A20 A2

4-Pole Relay. 2 Coil. [V] Hz A1 A2 60 Hz A24 A1 A20 A2 ulletin - Product Overview/Product Selection ulletin - Industrial Relay ontact cartridges convertible from.o. to.. and vice versa EM V coils Pneumatic timing unit Solid-state timing unit Overlap contacts

More information

RT4F-110V/25A RECTIFIER

RT4F-110V/25A RECTIFIER The RT4F-110V/25A is a hot-pluggable switched mode rectifier (SMR) module designed to provide up to 25A of output current into a 110V nominal system. Examples of such systems are 60 cells lead acid (136V

More information

Proximity Vibration / Position / Phase Reference Transmitters

Proximity Vibration / Position / Phase Reference Transmitters Proximity Vibration / Position / Phase Reference Transmitters Seismic Vibration Transmitters kmo turbo GmbH Friedrichstr. 59 88045 Friedrichshafen Germany Phone: +49 7541 95289-0 Fax: +49 7541 95289-20

More information

Series MV2000 MEDIUM VOLTAGE HIGH CURRENT POWER SUPPLIES

Series MV2000 MEDIUM VOLTAGE HIGH CURRENT POWER SUPPLIES FEATURES 2kW output power Output voltages from 20V to 300V High Packing Density - 2kW in 1U Parallel/series operation Stackable, cooling is front to rear Active Power Factor Correction Custom options available

More information

Arc protection relay. Features Three-phase overcurrent function. Application

Arc protection relay. Features Three-phase overcurrent function. Application Arc protection relay REA 10_ Page 1 Issued: May 1999 Status: New Data subject to change without notice Features Three-phase overcurrent function Loop-type or radial sensor fibre for arc detection Two high-speed

More information

ACCESS 9340/9360 Meter Input/Output Module

ACCESS 9340/9360 Meter Input/Output Module Installation Manual PMIM-IOMOD-0208 ACCESS 9340/9360 Meter Input/Output Module 9340-60-I/O2222 and 9340-60-I/O26 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the

More information

Isolated, Voltage or Current Input 7B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Voltage or Current Input 7B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Voltage or Current Input 7B41 FEATURES Interfaces, amplifies and filters unipolar and bipolar voltage inputs. Module provides a precision output of either +1 V to +5 V or 0 V to +10 V. All 7B41

More information

Chapter. Accessories. In This Chapter...

Chapter. Accessories. In This Chapter... ccessories hapter In This hapter... ccessories Overview... - / Power dapter... - / Power dapter imensions... - / Power dapter Installation... - -SU -pin to Terminal lock dapters... - Non-glare Screen overs...

More information