1 Vibration Transducer Interface Description The Vibration Transducer Interface (VTI) is a galvanic isolation solution provided by GE s Bently Nevada product line. With the use of galvanic isolation, an earth ground is not required in the hazardous area. Isolating transformers used in the galvanic isolation technique provide a physical barrier to prevent high voltages from being transferred from the safe area to the hazardous area. The safe area and hazardous area are isolated from each other, and can have two separate grounding points without the possibility of ground loops occurring. The Vibration Transducer Interface has been designed, engineered, and manufactured by Measurement Technology Limited to our design specifications. The Vibration Transducer Interface incorporates three-port isolation. The transducer, monitor, and power supply circuits each have separate grounding points, since the three circuits are isolated from each other. Therefore, +24 Vdc plant power, with its own ground, can be used to provide power to the Vibration Transducer Interface without creating ground loops. With the use of our1800/10 power supplies, 110 Vac or 220 Vac can also be used to power the Vibration Transducer Interface. Two power supplies can be installed in one housing. The following Bently Nevada transducer systems can be used with the Vibration Transducer Interface: 3300 XL Proximity Transducer System mm/8 mm Proximity Transducer System mm/8 mm Proximity Transducer PROXPAC Accelerometer Accelerometer Interface Module (part number ) Aeroderivative Interface Module (part number 86517) 3300 REBAM MicroPROX Proximity Transducer System 7200 REBAM MicroPROX Proximity Transducer System Page 1 of 8
2 The following Bently Nevada monitors can be used with the Vibration Transducer Interface: 3500/25 Keyphasor Monitor 3500/40 Proximitor Monitor 3500/42 Proximitor /Seismic Monitor 3500/44 Aeroderivative Monitor 3500/45 Differential Expansion/ Thrust Position Monitor 3500/50 Tachometer Monitor 3500/53 Overspeed Protection System 3300/16 Dual Vibration Monitor 3300/20 Dual Thrust Monitor 3300/25 Dual Accelerometer Monitor 3300/26 Dual Accelerometer RMS Monitor 3300/50 Tachometer 3300/52 Reverse Rotation Monitor 3300/53 Overspeed Protection System 3300/54 Dual REBAM Monitor 3300/61 Dual Vector Monitor 3300/81 Six-channel Rod Drop Monitor 3300/95 Aeroderivative Filter Module/Vibration Monitor 2201/02 System Monitor 2201/03 Four-channel PLC Monitor 2201/06 Low Speed Machine Monitor Page 2 of 8
3 Specifications Electrical Supply Voltage (Vs): Power Requirements, Vs: Isolation: Power Dissipation Within Unit: Minimum Transducer Supply Voltage (Terminals 2 and 6) Versus Load Current: Max Cross-Talk Noise Between Adjacent Isolators: The following specifications apply at 20 C (68 F) for one channel, unless otherwise noted, the temperature coefficient is 50 ppm/ C (+10 C to +65 C) and 100 ppm/ C (-20 C to +10 C). +20 Vdc to +35 Vdc. 88 ma at +20 Vdc, 80 ma at +24 Vdc, 63 ma at +35 Vdc. 250 Vac between input, power, and output circuits. 1.7 W Vdc at 12 ma, Vdc at 15 ma, Vdc at 22 ma. 11.3mV peak-to-peak (4mv RMS). Signal Range (Terminals 5 and 6, 7 and 8): Signal Input Impedance (Terminals 5 and 6): Signal Output Impedance (Terminals 7 and 8): DC Transfer Error: AC Transfer Error: Voltage Bandwidth: Phase Delay: Line Fault Detection: -20 Vdc to -0.5 Vdc. 10K Ω -1%, +2%. 20 Ω. ± 100 mv. ± 1% from 0 to 1 khz; -5% to +1% from 1 to 10 khz; -10% to +1% from 10 to 20 khz. -3 db at 43 khz (typical). Less than 14 µ sec, equivalent to: -1 degree at 200 Hz; -3 degrees at 600 Hz; -5 degrees at 1 khz; -50 degrees at 10 khz; -100 degrees at 20 khz. If signal input line breaks (opens), signal output drops to approximately 0V. Page 3 of 8
4 Monitor Leadwire Length: Transducer Leadwire Length: LED Indicators: Safety Description Terminals 2 to 4: Terminals 5 to 6: Hazardous Area Classifications: 30 metres (100 feet) maximum between monitor and Vibration Transducer Interface. For all applicable transducer systems: 305 metres (1000 feet) maximum between transducer module and Vibration Transducer Interface. The capacitance, inductance, and L/R parameters of the cable must be appropriate for the hazardous area classification. One green LED on top of module indicating power to module and two green LEDs on backplane indicating power sources are available V, 94 ma, 0.66 W. Non-energy-storing apparatus; 1.2 V, 0.1 A, 20 µj, and 25 mw. Approvals for hazardous areas for all compatible transducer systems are certified by BASEEFA / CENELEC for Zone 0, IIC, T4-6 except the Aeroderivative Interface Module, which is approved by SIRA /CENELEC for Zone 1, IIC, T4. Environmental Limits Operating Temperature: Storage Temperature: Relative Humidity: Enclosure Base: Lid: Finish Base: Lid: Lid fasteners: Protection: Permitted location: Ambient temperature limits: -20 C to + 65 C (-4 F to F). -40 C to +80 C (-40 F to +176 F). To 95%, noncondensing. GRP (glass-fiber-reinforced polycarbonate). Transparent high-strength polyester. Light gray. Transparent. Captive screws Dust-tight and water-jet proof to IEC529: IP65 Safe area. -20 C to +50 C (-4 F to +122 F), typical. Page 4 of 8
5 Ordering Information Note: When 3300 or 2201 monitors are ordered for use with the Vibration Transducer Interface, the monitors must be configured for no barriers. The 3500 monitors are configured for use with the Vibration Transducer Interface using the 3500/01 Rack Configuration Software. Vibration Transducer Interface AXX-BXX-CXX-DXX-EXX-FXX-GXX-HXX-IXX A: Housing Option 0 0 No housing required 0 1 With housing B: Position 1 Module C: Position 2 Module D: Position 3 Module E: Position 4 Module F: Position 5 Module G: Position 6 Module H: Position 7 Module I: Position 8 Module Power Supply (1800/10) AXX-BXX-CXX-DXX A Housing Option 0 0 No housing required 0 1 With housing B: Input Voltage to 135 Vac to 255 Vac C: Agency Approval 0 0 No Approvals D: Number of Power Supplies 0 1 One 0 2 Two Accessories Spares Power supply fuse. One fuse is installed in the backplane when it is shipped. MTL 4031 Isolator Page 5 of 8
6 Field wiring diagram Vibration Transducer Interface Figure 1: Vibration Transducer Interface Terminals Figure 2: Vibration Transducer Interface Dimensions are in millimetres (inches) Page 6 of 8
7 Figure 3: Vibration Transducer Interface Housing (also for use with power supplies) Dimensions are in millimetres (inches) Page 7 of 8
8 Figure 4: Vibration Transducer Interface Power Supply Dimensions are in millimetres (inches) Bently Nevada, PROXPAC, MicroPROX, Keyphasor, Proximitor and REBAM are trademarks of General Electric Company. Copyright Bently Nevada LLC Bently Parkway South, Minden, Nevada USA Phone: Fax: All rights reserved. Page 8 of 8
3500 Galvanic Isolator Interface Bently Nevada* Asset Condition Monitoring
3500 Galvanic Isolator Interface Bently Nevada* Asset Condition Monitoring Description The 3500 Galvanic Isolator Interface is an intrinsically safe interface that can be located between a transducer system
More information21000,24701 Proximity Probe Housing Assemblies Bently Nevada Asset Condition Monitoring
21000,24701 Proximity Probe Housing Assemblies Bently Nevada Asset Condition Monitoring Description Proximity Probe Housing Assemblies Bently Nevada offers two all-metal Proximity Probe Housing Assemblies
More information3500 Internal Barriers Product Datasheet Bently Nevada* Asset Condition Monitoring
GE Measurement & Control 3500 Internal Barriers Product Datasheet Bently Nevada* Asset Condition Monitoring Description 3500 Internal Barriers are intrinsically safe interfaces that provide explosion protection
More information3500/53 Electronic Overspeed Detection System
3500/53 Electronic Overspeed Detection System Description The Bently Nevada Electronic Overspeed Detection System for the 3500 Series Machinery Detection System provides a highly reliable, fast response,
More information3500/15 Power Supply. Description
3500/15 Power Supply Description The 3500 Power Supplies are half-height modules and must be installed in the specially designed slots on the left side of the rack. The 3500 rack can contain one or two
More information3500/15 Power Supply Bently Nevada* Asset Condition Monitoring
3500/15 Power Supply Bently Nevada* Asset Condition Monitoring Description The 3500 Power Supplies are half-height modules and must be installed in the specially designed slots on the left side of the
More information21022 Dual Axial Probe Housing Assembly Bently Nevada* Asset Condition Monitoring
21022 Dual Axial Probe Housing Assembly Bently Nevada* Asset Condition Monitoring Description The 21022 Dual Axial Probe Housing Assembly consists of two proximity probes installed in an externally mounted
More information3500/25 Enhanced Keyphasor*Module
3500/25 Enhanced Keyphasor*Module Product Datasheet Bently Nevada* Asset Condition Monitoring Description The 3500/25 Enhanced Keyphasor Module is a half-height, two-channel module used to provide Keyphasor
More information3500/77M Recip Cylinder Pressure Monitor
3500/77M Recip Cylinder Pressure Monitor Bently Nevada Asset Condition Monitoring Description The 3500/77M Recip Cylinder Pressure Monitor is a 4-channel monitor that accepts input from Bently Nevada approved
More information3500/45 Position Monitor
3500/45 Position Monitor Bently Nevada Asset Condition Monitoring Description The 3500/45 Position Monitor is a 4-channel monitor that accepts input from proximity transducers, Rotary Position Transducers
More information3500/45E Position Monitor
3500/45E Position Monitor Bently Nevada* Asset Condition Monitoring Description The 3500/45E Position Monitor is a 4-channel monitor that accepts input from proximity transducers, Rotary Position Transducers
More information9200, Seismoprobe
9200, 74712 Seismoprobe Description Bently Nevada Seismoprobe Velocity Transducer Systems are designed to measure absolute (relative to free space) bearing housing, casing, or structural vibration. The
More informationCase Expansion Transducer Systems
Case Expansion Transducer Systems Product Datasheet Bently Nevada* Asset Condition Monitoring Description Thermal Case Growth Measurements in Large Turbines An important position measurement in Turbine
More informationDescription. Specifications
R Specifications and Ordering Information 1701/15 FieldMonitor Proximitor Input Monitor for Radial Vibration and Thrust Position The 1701/15 FieldMonitor Proximitor Input Monitor is a 2-channel device
More information991 Thrust Transmitter Bently Nevada* Asset Condition Monitoring
991 Thrust Transmitter Bently Nevada* Asset Condition Monitoring Description The 991 Thrust Transmitter is intended primarily for the original equipment manufacturers (OEMs) of centrifugal air compressors
More information3300 RAM and NSv Proximity Transducer System
33 RAM and NSv Proximity Transducer System Description The 33 RAM and NSv Proximity Transducer system is intended for centrifugal air compressors, refrigeration compressors, process gas compressors and
More information1701/05 FieldMonitor* Terminal Base Bently Nevada* Asset Condition Monitoring
70/05 FieldMonitor* Terminal Base Bently Nevada* Asset Condition Monitoring Description The 70/05 Terminal Base is the mounting platform for the FieldMonitor* system for applications where transducers
More information3500/77M Recip Cylinder Pressure Monitor
3500/77M Recip Cylinder Pressure Monitor Product Datasheet Bently Nevada* Asset Condition Monitoring Description The 3500/77M Recip Cylinder Pressure Monitor is a 4-channel monitor that accepts input from
More informationTrendmaster* Galvanic Isolator
162459-01 Trendmaster* Galvanic Isolator Product Datasheet Bently Nevada* Asset Condition Monitoring Description The Trendmaster Galvanic Isolator enables the Trendmaster system to connect to intrinsically
More information991 Thrust Transmitter Bently Nevada* Asset Condition Monitoring
991 Thrust Transmitter Bently Nevada* Asset Condition Monitoring Description The 991 Thrust Transmitter is intended primarily for the original equipment manufacturers (OEMs) of centrifugal air compressors
More informationDescription. Improved Startup/Shutdown Data Collection: New Ethernet Link to Data Manager* 2000 computers. View Transient Plots during machine SU/SD
TDXnet* Bently Nevada* Asset Condition Monitoring Description The TDXnet Communications Processor provides the interface between our compatible (see note) machinery protection systems and our on-line machinery
More information3500/50E Tachometer Module
3500/50E Tachometer Module Bently Nevada* Asset Condition Monitoring Description The 3500/50E Tachometer Module is a 2-channel module that accepts input from proximity probes or magnetic pickups (except
More informationVelomitor * Piezo-velocity Sensor
Velomitor * Piezo-velocity Sensor Bently Nevada* Asset Condition Monitoring Description Velomitor * Piezo-velocity Sensors measure absolute (relative to free space) bearing housing, casing, or structural
More information3300 XL 11mm Proximity Transducer System
33 XL 11mm Proximity Transducer System Bently Nevada* Asset Condition Monitoring Description Transducer System The 33 XL 11 mm Proximity Transducer System consists of: 33 XL 11 mm probe 33 XL 11 mm extension
More information9200, Seismoprobe* Velocity Transducers
9200, 74712 Seismoprobe* Velocity Transducers Product Datasheet Bently Nevada* Asset Condition Monitoring Description Bently Nevada* Seismoprobe Velocity Transducer Systems are designed to measure absolute
More information3500 ENCORE System Overview Bently Nevada* Asset Condition Monitoring
3500 ENCORE System Overview Bently Nevada* Asset Condition Monitoring Description The 3500 ENCORE System provides continuous, online monitoring suitable for machinery protection applications and is designed
More informationDescription. Specifications and Ordering Information 9200, 74712, Seismoprobe Velocity Transducer System
R Specifications and Ordering Information 9200, 74712, 47633 Seismoprobe Velocity Transducer System Description Bently Nevada Seismoprobe Velocity Transducer systems are designed to measure absolute (relative
More informationVelomitor* CT Velocity Transducer
190501 Velomitor* CT Velocity Transducer Product Datasheet Bently Nevada* Asset Condition Monitoring Description The Velomitor CT Velocity Transducer is a low-frequency version of our standard Velomitor
More information9200, Seismoprobe * Bently Nevada* Asset Condition Monitoring
9200, 74712 Seismoprobe * Bently Nevada* Asset Condition Monitoring Description Bently Nevada Seismoprobe * Velocity Transducer Systems are designed to measure absolute (relative to free space) bearing
More informationIntrinsically Safe Barriers
Intrinsically Safe Barriers Description Page No. Safety Barriers 464-472 Din Rail Isolated Barriers 473-488 477 Intrinsically Safe Barriers Product Overview We have simplified intrinsic safety! Cooper
More information3500/95 System Integrated PC Display Bently Nevada* Asset Condition Monitoring
3500/95 System Integrated PC Display Bently Nevada* Asset Condition Monitoring Description The 3500/95 System Integrated PC Display provides local or remote visual indication of all 3500 Machinery Protection
More information3500/33 16-Channel Relay Module Bently Nevada* Asset Condition Monitoring
3500/33 16-Channel Relay Module Bently Nevada* Asset Condition Monitoring Description The 16-Channel Relay Module is a full-height module that provides 16 relay outputs. Any number of 16-Channel Relay
More information深圳市永旭伟业贸易有限公司. Description. a mm probe 1, 2 a 3300 XL extension cable (ref ) a 3300 Proximitor Sensor 3, 4, 5 (ref )
Specifications and Ordering Information 3300 5mm Transducer Patents: 5,016,343; 5,126,664; 5,351,388; and 5,685,884 R Description Transducer System The 3300 5mm Proximity Transducer System consists of:
More information3300 XL NSv Proximity Transducer System
Specifications and Ordering Information 33 XL NSv Proximity Transducer System Patents: 5,16,343; 5,126,664; 5,351,388; 5,685,884 Description Transducer System The 33 XL NSv Proximity Transducer system
More information3500/65 16-Channel Temperature Monitor
3500/65 16-Channel Temperature Monitor Bently Nevada* Asset Condition Monitoring Description The 3500/65 monitor provides 16 channels of temperature monitoring and accepts both resistance temperature detector
More informationand High Temperature Velomitor * System
330750 and 330752 High Temperature Velomitor * System Bently Nevada* Asset Condition Monitoring Description The standard 330500 Velomitor* Piezo-velocity Sensor has a limited temperature range it can be
More information3500/92 Communication Gateway
3500/92 Communication Gateway Description The 3500/92 Communication Gateway module provides extensive communication capabilities of all rack monitored values and statuses for integration with process control
More information3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring
3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring Description The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring system and GE s System 1* machinery
More information3300 XL High Temperature Proximity System
3300 XL High Temperature Proximity System Product Datasheet Bently Nevada* Asset Condition Monitoring Description Gas and steam turbines can produce temperatures hot enough to damage or destroy conventional
More informationTURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet
Process Automation IS Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to solve the problems associated with the
More information1900/65A General Purpose Equipment Monitor
1900/65A General Purpose Equipment Monitor Bently Nevada* Asset Condition Monitoring Description The 1900/65A General Purpose Equipment Monitor is designed to continuously monitor and protect equipment
More informationPART NUMBER REVISION E, 3300 SYSTEM COMPATIBILITY GUIDE
PART NUMBER 104003-01 REVISION E, 3300 SYSTEM COMPATIBILITY GUIDE 104003-01 3300 System Compatibility Guide NOTICE READ THE FOLLOWING BEFORE INSTALLING OR OPERATING EQUIPMENT Bently Nevada Corporation
More informationMTL830 SERIES. Cuts installation and cable costs for all IS hazardous-area circuits
830 SERIES Cuts installation and cable costs for all IS hazardous-area circuits Reduce the cost of installing hazardous-area cabling Save installation time, space and weight Highlight problems quickly
More information3500/32M 4-Channel Relay Module
3500/32M 4-Channel Relay Module Bently Nevada* Asset Condition Monitoring Description The 4-Channel Relay Module is a full-height module that provides four relay outputs. Any number of 4-Channel Relay
More information5 Fieldbus Technology
5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically
More informationZener Barriers Bulletin 937Z
Technical Data Zener Barriers Bulletin 937Z Topic Page Introduction 2 Mounting 2 Housing 3 Operating Principle 3 Specifications 6 Introduction Allen-Bradley Zener barriers are a cost-effective solution
More informationI-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS
I-7520 RS-232 to RS-485 Converter I-7510 RS-485 Repeater RS-232 RS-485 I-7000 SERIES Common Specifications Isolation voltage: 3000VDC Speed: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115000 Dual watchdog
More informationOperating Instructions
Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on
More information3500/22M Transient Data Interface Module
3500/22M Transient Data Interface Module Product Datasheet Bently Nevada* Asset Condition Monitoring Description The 3500/22M Transient Data Interface (TDI) is the interface between the 3500 monitoring
More informationRanger* Pro Wireless Condition Monitoring
Ranger* Pro Wireless Condition Monitoring Datasheet Bently Nevada* Asset Condition Monitoring Product Datasheet The Ranger* Pro Wireless Condition Monitoring wireless vibration sensor allows you to monitor
More informationAPPLICATION GUIDE. Interface Modules IM Series.
Interface Modules IM Series APPLICATION GUIDE www.turck.com Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to
More informationSafety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.
Safety Barriers Description Safety barriers limit the energy fed to an intrinsically safe circuit so that neither sparks nor thermal effects (hot surfaces) can cause an explosion. CEAG safety barriers
More information3500/23E Transient Data Interface
3500/23E Transient Data Interface Bently Nevada* Asset Condition Monitoring Description The 3500/23E Transient Data Interface (TDI) is the interface between the 3500 ENCORE monitoring system and GE s System
More informationTermination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.
Termination Board HiCTB08-SCT-C-SC-RA Features Assembly For 8 modules V DC supply Supported signal types: DI/DO/AI/TI/AO Hazardous area: screw terminals, blue Safe area: screw terminals, black Function
More informationIsolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated Voltage Input 7B31 FEATURES Interfaces, amplifies, and filters unipolar and bipolar voltage inputs. Module provides a precision output of either +1 V to +5 V or 0 V to +10 V, linear with temperature.
More information3500/23E Transient Data Interface
3500/23E Transient Data Interface Bently Nevada* Asset Condition Monitoring Description The 3500/23E Transient Data Interface (TDI) is the interface between the 3500 ENCORE monitoring system and GE s System
More information3300 XL NSv* Proximity Transducer System Bently Nevada* Asset Condition Monitoring
33 XL NSv* Proximity Transducer System Bently Nevada* Asset Condition Monitoring Description The 33 XL NSv* Proximity Transducer system is intended for use with centrifugal air compressors, refrigeration
More informationOperating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505
Operating Instructions Intrinsically Safe Isolation Relay for Switches Model: REL-6003 manual_rel-6_0505 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating
More informationProximity Transducers, Seismic Sensors and Accessories
8mm, 5mm Proximity Probe TM0180 and TM0105 Systems Introduction to proximity probe transducers Proximity probe transducers are used to measure the static and dynamic distance between the target and the
More informationTermination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.
Features Assembly System board for Honeywell Safety Manager For 6-channel AI card SAI-60m For 6 modules Recommended module: HiC05 (AI) 4 V DC supply Hazardous area: pluggable screw terminals, blue Non-hazardous
More informationIsolated Process Current Input with Loop Power 7B35
Isolated Process Current Input with Loop Power 7B35 FEATURES Single-channel signal conditioning current input module that interfaces with two-wire transmitters. Module provides a precision output of either
More informationIsolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated Process Current Input 7B32 FEATURES Interfaces, amplifies and filters a process-current input. Module provides a precision output of either +1 V to +5 V or 0 V to +10 V, linear with temperature.
More informationand High Temperature Velomitor * System
330750 and 330752 High Temperature Velomitor * System Product Datasheet Bently Nevada* Asset Condition Monitoring Description The standard 330500 Velomitor* Piezo-velocity Sensor has a limited temperature
More informationIsolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated, Voltage or Current Input 7B30 FEATURES Interfaces, amplifies and filters unipolar and bipolar millivolt and voltage inputs. Provides a protected precision output of either +1 V to +5 V or 0 V
More informationFLEX Ex Spring Clamp Terminal Base
Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification
More informationInstallation & Operation Manual
Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas
More informationApprovals Quick Reference Guide Country Specific Ordering Options Bently Nevada* Asset Condition Monitoring
GE Measurement & Control Approvals Quick Reference Guide Country Specific Ordering Options Bently Nevada* Asset Condition Monitoring Document Summary This reference guide represents an overview of all
More informationDigital Output Module 8-Channel Version for Zone 1 Series 9475/
www.stahl.de > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >
More information3300 XL 11mm Proximity Transducer System
33 XL 11mm Proximity Transducer System Bently Nevada* Asset Condition Monitoring Description Transducer System The 33 XL 11 mm Proximity Transducer System consists of: 33 XL 11 mm probe 33 XL 11 mm extension
More informationDual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx
D224 Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx D224 Front View KEY FEATURES SIL1 / IEC 61508:2010 compliant Dual Channel Speed and Ratio Monitor with
More informationTermination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.
Features Assembly System board for Honeywell Universal Safety IO System board for Honeywell Universal Process IO For 6-channel cards USIO and UPIO For 6 modules Recommended modules: HiC8R (DI), HiC85R
More information8mm, 5mm Proximity Probe TM0180 and TM0105 Systems
8mm, 5mm Proximity Probe TM0180 and TM0105 Systems Introduction to proximity probe transducers Proximity probe transducers are used to measure the static and dynamic distance between the target and the
More information3500/08 Diagnostics Access Panel
Part number 136275-01 Revision A, June 2005 3500/08 Diagnostics Access Panel Operation and Maintenance Manual Copyright 1997 Bently Nevada LLC All Rights Reserved. The information contained in this document
More information3300 XL 8mm Proximity Transducer System
33 XL 8mm Proximity Transducer System Description The 33 XL 8 mm Proximity Transducer System consists of: a 33 XL 8 mm probe a 33 XL extension cable a 33 XL Proximitor Sensor 1 The system provides an output
More information3300 XL 8mm Proximity Transducer System Bently Nevada* Asset Condition Monitoring
33 XL 8mm Proximity Transducer System Bently Nevada* Asset Condition Monitoring Description The 33 XL 8 mm Proximity Transducer System consists of: One 33 XL 8 mm probe, One 33 XL extension cable 1, and
More informationtechnical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas
technical datasheet technical datasheet MTL0 Displays Loop-powered indicators for hazardous areas Loop powered -0mA Field and panel mounting Environmental protection to IP7 Easy to configure Number of
More informationAssembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail
Switch Amplifier KCD-SR-Ex.LB Features Assembly -channel isolated barrier V DC supply (Power Rail) Dry contact or NAMUR inputs Usable as signal splitter ( input and outputs) Relay contact output Fault
More informationDigital Output Module 8-Channel Version for Zone 2 Series 9475/
> 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in
More informationMODEL SW6000 & SM6100 CENELEC INSTRUCTIONS
MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS Installation Manual 1180 METRIX Experience Value 8824 Fallbrook Dr. Houston, TX 77064, USA Tel: 1-281-940-1802 After Hours Technical Assistance: 1-713-702-8805
More informationECT Signal Isolator/Converter
August 1997 Now with Dual I/O Channels Data Sheet 2.02 Description The family of signal isolators and converters delivers economical solutions for a wide variety of signal interface applications. Isolator
More informationLevel-Lance Model 5400A
Sales Manual Section 100 PRODUCT SPECIFICATION 5400A GENERAL DESCRIPTION The ROBERTSHAW Level-Lance Model 5400A is a microprocessor based, multi-point On-Off capacitance type level detection system. Utilizing
More informationProximity Transducers, Seismic Sensors and Accessories
PVTVM s Proximity Selection Guide Part Number (Initial Prefix) TM0105 TM0180 TM0110 TM0120 Tip Size 5mm 8mm 11mm 25mm Model Type Standard, Standard, Standard, 7200 compatible 7200 compatible 7200 compatible
More informationDigital Output Module 4-Channel Version for Zone 1 Series 9475/
www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ib > Suitable for Ex i hydraulic valves and solenoid valves > Additional Ex i control input for (in accordance with IEC 61508 through
More informationOperation and Maintenance Manual. 3500/42 Proximitor/Seismic Monitor Module. Part Number Rev. H (07/07)
Operation and Maintenance Manual 3500/42 Proximitor/Seismic Monitor Module Part Number 129773-01 Rev. H (07/07) 3500/42 Proximitor/Seismic Monitor Module Operation and Maintenance Manual Copyright 1995
More informationDeltaV Bulk Power Supplies
DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to
More informationProximity Transducers, Seismic Sensors and Accessories
11mm Proximity Probe TM0110 System Linear range The 11mm probe has up to 4mm (160mil) linear range. The TM0110 probe is recommended when a longer linear range is required. The TM0110 proximity probe system
More informationIsolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated, Process Current Output 7B39 FEATURES Interfaces, isolates and filters a 0 V to + 10 V or +1 V to +5 V input signal. Provides an isolated process current output of 0 ma to 20 ma or 4 ma to 20
More information5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
5B Series 16 Channel Backplane 5B01 FEATURES Mix and Match 5B Series I/O Module Capability Factory Mutual (FM) Approved Approved for Use in Class I, Division2, Groups A, B, C, and D Locations. CE Certified:
More informationAssembly MAU. MUX 4 Channels 8 Channels Zone 1
Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.
More informationInstallation & Operation Manual
Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas
More informationAnalyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK
Instruction Sheet PN 51A-54epH/rev J October 2010 ph/orp HART Model 54e ph/orp Analyzer/Controller For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. ESSENTIAL
More informationPHOENIX CONTACT - 12/2007
Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel
More informationM-series Intrinsically Safe I/O
DeltaV Distributed Control System Product Data Sheet M-series Intrinsically Safe I/O Features full system modularity Reduces system footprint Decreases installation time and expense Plug-and-play installation
More informationDigital Output Module 4-Channel Version for Zone 1 Series 9475/
www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >
More informationModel 7705 Control Module
www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be
More informationADAPT 3701/46 Hydro Monitor Bently Nevada* Asset Condition Monitoring
ADAPT 3701/46 Hydro Monitor Bently Nevada* Asset Condition Monitoring Advanced Distributed Architecture Platform Technology - ADAPT GE s Bently Nevada Advanced Distributed Architecture Platform Technology,
More information3500/22M Transient Data Interface
Specifications and Ordering Information 3500/22M Transient Data Interface Description The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring system and Bently Nevada s System
More informationProximity Vibration / Position / Phase Reference Transmitters
Proximity Vibration / Position / Phase Reference Transmitters Seismic Vibration Transmitters kmo turbo GmbH Friedrichstr. 59 88045 Friedrichshafen Germany Phone: +49 7541 95289-0 Fax: +49 7541 95289-20
More informationIsolated Process Current Output 3B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated Process Current Output 3B39 FEATURES Interfaces, isolates, & filters a 0 to +10V or -10V to +10V input signal and provides an isolated process current output across loads of 0 to 850Ω.. Intended
More informationApprovals Quick Reference Guide Country Specific Ordering Options Bently Nevada* Asset Condition Monitoring
GE Measurement & Control Approvals Quick Reference Guide Country Specific Ordering Options Bently Nevada* Asset Condition Monitoring Document Summary This reference guide represents an overview of all
More information