More outlets. More flexibility. Highest quality.

Size: px
Start display at page:

Download "More outlets. More flexibility. Highest quality."

Transcription

1 The New ProGrade PU Zero-U Rack Mounted abinet PUs with Outlets More outlets. More flexibility. Highest quality. 00-0V Single-Phase 0/ 0V -Phase 0 00 & V -Phase & 0 Looking for more outlets, more flexibility & and professional grade quality in a smaller form factor? Introducing our new ProGrade : outlet Smart PU so you can pack more power and more devices into your data center racks. The high outlet count of mixed outlets makes the it the one PU to power blade or traditional servers. The outlets have a middle display that can be inverted, for overhead or under the floor power, and our next-generation locking receptacles. When paired with Server Technology s locking power cords, you ll have peace of mind knowing that your servers will stay safely plugged into the cabinet PU. These network addressable Smart Us support an additional link unit using a single IP address as well as temperature & humidity probes ( via the master, via the link unit). The ProGrade is now available with the PU Power Pivot, which provides a 90 degree rotatable power cord making it the ultimate PU with the flexibility to mount in racks with either overhead or raised floor power feeds. vailable capacities include 0-0V 0, 0V, -Phase elta and Wye 0V 0, 00/0V, and /0V 0. Features Include Power Pivot Per Inlet Power Sensing Link to an expansion U Temp & Humidity Monitoring Network Monitoring Input urrent Monitoring Locking Outlets ranch ircuit Protection utton Mounting

2 The New ProGrade PU Zero-U Rack Mounted abinet PUs with Outlets Models North merica Master Expansion Input Input urrent Input Plug STV-0 SEV V, 0/0 Hz 0 (e-rated ) NEM L-0P, 0 ft ( m) cord STV-0M SEV-0M 0 V, -phase Wye, 0/0 Hz 0 (e-rated ) NEM L-0P, 0 ft ( m) cord STV-0V SEV-0V 0 V, -phase Wye, 0/0 Hz 0 (e-rated 0) S, 0 ft ( m) cord STV-0 SEV-0 0/ V, -phase Wye, 0/0 Hz 0 (e-rated ) IE 009 P+N+G, hr (Red), 0 ft ( m) cord STV-0 SEV-0 0/ V, -phase Wye, 0/0 Hz 0 (e-rated ) IE 009 P+N+G, hr (Red), 0 ft ( m) cord STV-0Z SEV-0Z 0/ V, -phase Wye, 0/0 Hz 0 (e-rated ) NEM L-0P, 0 ft ( m ) cord Global Master Expansion Input Input urrent Input Plug STV-0K SEV-0K 0 V, 0/0 Hz IE 009 P+G, hr (lue), m (0 ft) cord STV-0J SEV-0J 0/00 V, -phase Wye, 0/0 Hz IE 009 P+N+G, hr (Red), m (0 ft) cord STV-0K SEV-0K 0/00 V, -phase Wye, 0/0 Hz IE 009 P+N+G, hr (Red), m (0 ft) cord Specifications Input PIPS Monitoring Parameters: Input current (), voltage (V), power (kw), apparent power (V), power consumption (W-hr), crest factor, power factor Meets or exceeds NSI. for +/- % illing Grade ccuracy (independently tested by UL) Power cord: Top-entry with PU Power Pivot Output* Type: () IE 00/ and () IE 00/9 Voltage: 00-0 V * Note: Models S[ ]V-0M include an unmonitored 00-0 V NEM -0R auxiliary outlet isplay S[ ]V-0[ ]: () Input current LE, auto-rotating S[ ]V-0[ ] and S[ ]V-0[ ]: () Input line current LEs, auto-rotating Temperature/Humidity Sensors () ombination temperature/humidity sensor inputs per Master or Expansion PU ranch ircuit Protection ompliant to UL 090-, UL 9 Model S[ ]V-0 S[ ] V-0 S[ ]V-0 Number of branches and Type of ranch ircuit Overload Protection, UL9 double-pole, single-throw 0 circuit breakers, UL9 double-pole, single-throw 0 circuit breakers, UL9 single-pole, single-throw 0 circuit breakers imensions and Weights Model imensions (LxWx) Shipping imensions (LxWx) Shipping Weight S[ ]V x. x. in. ( x x mm) x x in. (9 x x cm) lb. (. kg) S[ ] V x. x. in. ( x x mm) x x in. (9 x x cm) lb. (0 kg) S[ ]V x. x. in. ( x x mm) x x in. (9 x x cm) lb. (0 kg)

3 The New ProGrade PU Zero-U Rack Mounted abinet PUs with Outlets Specifications (ontinued) Interface and Protocol Support Master PU 0-00 Mbps Ethernet (RJ- connector) RS- serial (RJ- connector) () temperature/humidity sensor inputs (RJ-) Link port (RJ-) Web browser and serial interface HTTP/HTTPS, SSLv/TLSv, SSHv, Telnet SNMPv and v (TRPS, GET, SET) IPv and IPv LPv/LPS, TS+, RIUS Warranty years ertifications North merica ctuvus Mark to UL 090-: 00 and N/S. No F lass, Part EM to EN 0 lass, EN 0, ISPR lass Global TUVGS Mark to EN 090-: 00 + F lass, Part EM to EN 0 lass, EN 0, ISPR lass E Mark RoHS/WEEE Environmental Requirements Operating Storage Temperature to 0 F (0 to 0 ) -0 to F (-0 to ) Relative Humidity % to 90% non-condensing % to 90% non-condensing ccessories escription Temperature/Humidity Sensor Environmental Monitor ontrol Unit Part Number EMTH-- EMU-- Server Technology LockedIn Power ord Options UL Rated UL Rated Plug onnector Length olor Part Number. ft (0. m) lack -S-.0 ft (0.9 m) lack (Red) -S-F(FR).0 ft (. m) lack (Red) -S-N(NR) 0.0 ft ( m) lack -S-W 9.0 ft (0.9 m) lack -S9-F 9.0 ft (. m) lack -S9-N 0. ft (0. m) lack -S0-0.0 ft (0.9 m) lack -S0-F 0.0 ft (. m) lack -S0-N 0 9. ft (0. m) lack -S ft (0.9 m) lack (Red) -S09-F(FR) ft (. m) lack (Red) -S09-N(NR) VE Rated Plug onnector Length olor Part Number 0. m (0 in) lack -S-V.0 m (9 in) lack (Red) -S-GV(GS).0 m ( in) lack (Red) -S-PV(PS) 0.0 m (9 in) lack -S0-GV 0.0 m ( in) lack -S0-PV m (0 in) lack -S09-V m (9 in) lack (Red) -S09-GV(GS) m ( in) lack (Red) -S09-PV(PS) * Note: the bend of the angled cords is referenced with the ground pin at the top Server Technology, Inc. 0 version. Information in this document is subject to change without notice. Sentry and Server Technology are trademarks of Server Technology, Inc. Printed in US.

4 The New ProGrade PU Zero-U Rack Mounted abinet PUs with Outlets S[ ]V-0 SERVER TEHNOLOGY, IN PROPRIETRY INFORMTION THIS OUMENT IS THE SOLE PROPERTY OF SERVER TEHNOLOGY, IN. THE RELESE OF T ONTINE IN THIS OUMENT N THE REPROUTION OF THIS OUMENT, IN WHOLE OR IN PRT, WITHOUT THE WRITTEN PERMISSION OF SERVER TEHNOLOGY, IN IS PROHIITE. RoHS OMPLINT REVISION HISTORY ZONE REV ESRIPTION TE PPROVE - INITIL ESIGN //0 JSL/V E." MOUNTING PTTERN /9/0 JSL/V THESE OMMOITIES, TEHNOLOGY OR SOFTWRE WERE EXPORTE FROM THE UNITE STTES IN ORNE WITH THE EXPORT MINISTRTION REGULTIONS. IVERSION ONTRRY TO U.S. LW IS PROHIITE. NOTES:. IMENSIONS RE IN MILLIMETERS N [ ] RE IN INHES.. IMENSIONS RE NOMINL. INFORMTION SUJET TO HNGE WITHOUT NOTIE.. [9.00] 9. [.] 9. [.]. [.9] 0.0 [0.9]. [.] 99. [.] 0.0 [0.9]. [.9] 99. [.] 9. [.]. [.] 9. [.] X. [0.0]. [9.0]. [.] 9. [.]. [.9]. [9.0]. [.] TOLERNES UNLESS OTHERWISE SPEIFIE (UNLESS OTHERWISE SPEIFIE) * INTERPRET RWING IW SME Y LINER IMENSIONS: * IMENSIONING & TOLERNING IW SME Y.M-00.X = ±.00 * REMOVE LL URRS N SHRP EGES. R MX.XX = ±.00 * IMENSIONS RE IN MILLIMETERS.XXX = ±.0 * IMENSIONL LIMITS PPLY FTER PLTING/OTING. O NOT SLE RWING NGULR IMENSIONS: THIR NGLE PROJETION X = ± X.X = ±. X.XX = ±. SERVER TEHNOLOGY, IN. RWING TITLE: 00 Sandhill rive Reno, NV 9 OUTLINE RWING, Smart Pips V SYMOLS MTERIL: Q # = RITIL IM. S = OSMETI SURFE FINISH: SIZE GE OE WG NO. REV 09V0-00- SLE: NONE OF SHEET

5 The New ProGrade PU Zero-U Rack Mounted abinet PUs with Outlets S[ ] V-0 SERVER TEHNOLOGY, IN PROPRIETRY INFORMTION THIS OUMENT IS THE SOLE PROPERTY OF SERVER TEHNOLOGY, IN. THE RELESE OF T ONTINE IN THIS OUMENT N THE REPROUTION OF THIS OUMENT, IN WHOLE OR IN PRT, WITHOUT THE WRITTEN PERMISSION OF SERVER TEHNOLOGY, IN IS PROHIITE. RoHS OMPLINT REVISION HISTORY ZONE REV ESRIPTION TE PPROVE - INITIL ESIGN //0 JSL/V E." MOUNTING PTTERN /9/0 JSL/V THESE OMMOITIES, TEHNOLOGY OR SOFTWRE WERE EXPORTE FROM THE UNITE STTES IN ORNE WITH THE EXPORT MINISTRTION REGULTIONS. IVERSION ONTRRY TO U.S. LW IS PROHIITE. NOTES:. IMENSIONS RE IN MILLIMETERS N [ ] RE IN INHES.. IMENSIONS RE NOMINL. INFORMTION SUJET TO HNGE WITHOUT NOTIE.. [9.00] 9. [.] 9. [.] 0.0 [0.9] 99. [.]. [.9]. [.] 0.0 [0.9]. [.9] 99. [.] 9. [.]. [.] 9. [.] X. [0.0]. [9.0]. [.] 9. [.]. [.9]. [9.0]. [.] TOLERNES UNLESS OTHERWISE SPEIFIE (UNLESS OTHERWISE SPEIFIE) * INTERPRET RWING IW SME Y LINER IMENSIONS: * IMENSIONING & TOLERNING IW SME Y.M-00.X = ±.00 * REMOVE LL URRS N SHRP EGES. R MX.XX = ±.00 * IMENSIONS RE IN MILLIMETERS.XXX = ±.0 * IMENSIONL LIMITS PPLY FTER PLTING/OTING. O NOT SLE RWING NGULR IMENSIONS: THIR NGLE PROJETION X = ± X.X = ±. X.XX = ±. SERVER TEHNOLOGY, IN. RWING TITLE: 00 Sandhill rive Reno, NV 9 OUTLINE RWING, Smart Pips V SYMOLS MTERIL: Q # = RITIL IM. S = OSMETI SURFE FINISH: SIZE GE OE WG NO. 09V0 SLE: NONE -00- REV SHEET OF

6 The New ProGrade PU Zero-U Rack Mounted abinet PUs with Outlets S[ ]V-0 SERVER TEHNOLOGY, IN PROPRIETRY INFORMTION THIS OUMENT IS THE SOLE PROPERTY OF SERVER TEHNOLOGY, IN. THE RELESE OF T ONTINE IN THIS OUMENT N THE REPROUTION OF THIS OUMENT, IN WHOLE OR IN PRT, WITHOUT THE WRITTEN PERMISSION OF SERVER TEHNOLOGY, IN IS PROHIITE. RoHS OMPLINT REVISION HISTORY ZONE REV ESRIPTION TE PPROVE - INITIL ESIGN //0 JSL/V E." MOUNTING PTTERN /9/0 JSL/V THESE OMMOITIES, TEHNOLOGY OR SOFTWRE WERE EXPORTE FROM THE UNITE STTES IN ORNE WITH THE EXPORT MINISTRTION REGULTIONS. IVERSION ONTRRY TO U.S. LW IS PROHIITE. NOTES:. IMENSIONS RE IN MILLIMETERS N [ ] RE IN INHES.. IMENSIONS RE NOMINL. INFORMTION SUJET TO HNGE WITHOUT NOTIE.. [9.00] 9. [.] 9. [.] 0.0 [0.9]. [.9]. [.] 99. [.] 0.0 [0.9]. [.9] 99. [.] 9. [.]. [.] 9. [.] X. [0.0]. [9.0]. [.] 9. [.]. [.9]. [9.0]. [.] TOLERNES UNLESS OTHERWISE SPEIFIE (UNLESS OTHERWISE SPEIFIE) * INTERPRET RWING IW SME Y LINER IMENSIONS: * IMENSIONING & TOLERNING IW SME Y.M-00.X = ±.00 * REMOVE LL URRS N SHRP EGES. R MX.XX = ±.00 * IMENSIONS RE IN MILLIMETERS.XXX = ±.0 * IMENSIONL LIMITS PPLY FTER PLTING/OTING. O NOT SLE RWING NGULR IMENSIONS: THIR NGLE PROJETION X = ± X.X = ±. X.XX = ±. SERVER TEHNOLOGY, IN. RWING TITLE: 00 Sandhill rive Reno, NV 9 OUTLINE RWING, Smart Pips V SYMOLS MTERIL: Q # = RITIL IM. S = OSMETI SURFE FINISH: SIZE GE OE WG NO. 09V0 SLE: NONE -00- REV SHEET OF HEQURTERS - NORTH MERI Server Technology, Inc. 00 Sandhill rive Reno, NV 9 United States Tel...0 Fax sales@servertech.com Western Europe, Middle East and frica Server Technology Fountain ourt Victoria Square Victoria Street St. lbans L TF United Kingdom + (0) Tel + (0) 0 Fax salesint@servertech.com entral Europe, Eastern Europe and Russia Niederlassung eutschland Server Technology LL 9 Wuppertal Germany Tel: x 0 Fax: salesint@servertech.com P Server Technology Room 0, /F, Future Plaza - How Ming Street, Kwun Tong, Hong Kong irect line: Fax Line: salesint@servertech.com

CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. Available in Basic, Metered, and Smart PDU models.

CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. Available in Basic, Metered, and Smart PDU models. CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. You ve never seen anything like this before. TM Introducing the PDU Power Pivot, the newest patented innovation from Server Tech, inventors of

More information

Models. Specifications

Models. Specifications CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. You ve never seen anything like this before. Intro- TM ducing the PDU Power Pivot, the newest patented innovation from Server Tech, inventors

More information

Sentry Metered, Smart, and Switched High Density 30 Receptacle 208VAC, 3-Phase 30A Products

Sentry Metered, Smart, and Switched High Density 30 Receptacle 208VAC, 3-Phase 30A Products Sentry Metered,, and High Density 30 Receptacle 208VAC, 3-Phase 30A Products The shift to 3-Phase power in North American data centers has driven demand for PDUs with increased flexibility. Mixed C13 /

More information

Server Technology Technical Data Sheet

Server Technology Technical Data Sheet Technical Data Sheet -48VDC Switched Rack PDU 48DCWB-04-4X125-E0NB: 24kW (4) 125A Inputs and (4)125A Max Outputs Sep 2016 Version 1.0 This Intelligent PDU and Remote Power Manager minimizes the impact

More information

Fail-Safe Power Redundancy

Fail-Safe Power Redundancy Fail-Safe Power Redundancy Automatic Transfer Switch for Single-Cord Devices The Server Technology Fail-Safe Transfer Switch (FSTS) provides fail-over redundancy to single or dual power supply servers

More information

Server Technology Inc.

Server Technology Inc. Server Technology Inc. Alternating Phase Power Distribution at the Data Center Rack PDU White Paper STI-100-012 2013-April-18 By Steve Hammond, Product Manager, Server Technology Headquarters Server Technology,

More information

CS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link)

CS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link) CS-10H0A413H3 (Master) CL-10H0A413H3 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while

More information

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link)

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link) CS-12HDE444C8 (Master) CL-12HDE444C8 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while

More information

METRIC. Gamma Vacuum BOTTOM VIEW MOUNTING HOLE PATTERN E 25S-XX-2V-XX

METRIC. Gamma Vacuum BOTTOM VIEW MOUNTING HOLE PATTERN E 25S-XX-2V-XX 0 E WG. NO. SH. (. ) [.] THIS RWING HS EEN GENERTE N IS MINTINE Y PRO/ENGINEER SYSTEM. (. ) [.] (. ) [.] ( 0. ) [.] (. ) [.9] IM FTHRU MM INH S 9.. KG 9.. SO 9.. FI 0.. OV.. VR 0..9 LE 0.. M x.0 x. OP

More information

C2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) Key Features

C2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) Key Features C2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) The Server Technology PRO2 Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine

More information

CS-24VD-L30MA (Master) Key Features. CL-24VD-L30MA (Link)

CS-24VD-L30MA (Master) Key Features. CL-24VD-L30MA (Link) CS-24VD-L30MA (Master) CL-24VD-L30MA (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while

More information

How do I... If you manage a datacenter, we have a solution for you.

How do I... If you manage a datacenter, we have a solution for you. If you manage a datacenter, we have a solution for you. How do I... Distribute power to all the equipment in the cabinet? Reboot remote servers and network devices? Know when the cabinet temperature is

More information

How do I... Sentry Power Manager Rack-Level Data Center Power Monitoring & Management. If you manage a datacenter, we have a solution for you.

How do I... Sentry Power Manager Rack-Level Data Center Power Monitoring & Management. If you manage a datacenter, we have a solution for you. Rack-Level Data Center Power Monitoring & Management If you manage a datacenter, we have a solution for you. How do I... Get ultra-reliable power distribution within the data center along with the ability

More information

Server Technology Inc.

Server Technology Inc. Server Technology Inc. Power Efficiency Gains by Deploying 415 VAC Power Distribution in North American Data Centers White Paper STI-100-008 2011-Sept-22 Headquarters Server Technology, Inc. 1040 Sandhill

More information

Density in the Data Center

Density in the Data Center Density in the Data Center INDUSTRY BRIEF Aug 2014 Density in the datacenter refers to the electric power consumed per square foot of floor space (or unit volume of space), number of servers, and the cooling

More information

Introducing Server Technology s PRO1 Rack Power Distribution Unit

Introducing Server Technology s PRO1 Rack Power Distribution Unit Introducing Server Technology s PRO1 Rack Power Distribution Unit Purpose This technical note provides an introduction to the features of the PRO1 hardware and user interface. What is the PRO1? The PRO1

More information

Tripp Lite Network-Grade Power Distribution Units (PDUs)

Tripp Lite Network-Grade Power Distribution Units (PDUs) T N L P P L T O N U L L T N # 9 5-3 0 8 4 Tripp Lite Network-rade Power istribution Units (PUs) Tripp Lite Network-rade PUs are extremely reliable multiple-outlet strips that distribute power from a UPS

More information

PART NUMBER THIS DRAWING IS A CONTROLLED DOCUMENT. DIMENSIONING AND TOLERANCING PER ASME Y14.5M-2009 DIMENSIONS: mm

PART NUMBER THIS DRAWING IS A CONTROLLED DOCUMENT. DIMENSIONING AND TOLERANCING PER ASME Y14.5M-2009 DIMENSIONS: mm THIS RWING IS UNPULISHE. OPYRIGHT 0 RELESE FOR PULITION 0 LO GP LL RIGHTS RESERVE. Y IST 00 P LTR HET SINK X LIGHT PIPE ESRIPTION TE WN PV RELESE TO PROUTION PR0 KQ SH REVISE PER EO0 FE0 JW SH REVISE PER

More information

Power Distribution Units for Data Centers

Power Distribution Units for Data Centers BRC_PowerMax_INT_Draft_I.qxp_Layout 1 9/11/17 2:00 PM Page 2 Power Distribution Units for Data Centers WWW.SIEMON.COM PowerMax Power Distribution Units 2 Siemon s PowerMax line of PDUs range from basic

More information

RELEASE OF NEW 5 TOUCHSCREEN DISPLAY

RELEASE OF NEW 5 TOUCHSCREEN DISPLAY RELESE OF NEW TOUHSREEN ISPLY LL 909 ESRIPTION SEKEEPER has designed a new touchscreen display that takes all of the features of the 3. display and incorporates them into a sleek new display that also

More information

Power Distribution. For technical support call Online catalog available at leviton.com 461

Power Distribution. For technical support call Online catalog available at leviton.com 461 INDEX FLX Series... 463 Switched Series... 464 Metered Series... 465 P1000 Series... 466 5500 & 5505 Series... 467 4500 Series... 468 For technical support call 800-824-3005 Online catalog available at

More information

OPTIONAL OSD REMOTE P/N E (1 INCLUDED WITH TOUCHMONITOR)

OPTIONAL OSD REMOTE P/N E (1 INCLUDED WITH TOUCHMONITOR) PROPRIETRY TO ELO TOUH SOLUTIONS, IN. N SHLL NOT E ISLOSE OTHER THN TO NEESSRY EMPLOYEES OR SUPPLIERS WITHOUT THE EXPRESS WRITTEN ONSENT OF ELO TOUH SOLUTIONS IN. Y ISIONS ESRIPTION -- KJN INITIL RELESE

More information

5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA

5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA Management Interface The management interface for this PDU model is transitioning to a new technology platform. The new interface can be distinguished by a USB-A port (for EnviroSense2 modules) in place

More information

25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA

25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA 25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC 309 60A Red 415V, 0U, TAA MODEL NUMBER: PDU3XEVSR6G60B Highlights 25.2kW 240V 3-phase switched 1.8m

More information

Server Technology White Paper

Server Technology White Paper Server Technology White Paper WP Bottom-Up Data Center Power Management White Paper STI-100-017 2016-April Overview Outlet switching and outlet-level power measurements are critical for the modern data

More information

IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide

IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide The IBM 1U Switched and Monitored Power Distribution Units (PDUs) make it quick and simple to deploy, protect, and

More information

Power Xpert Branch Circuit Monitor

Power Xpert Branch Circuit Monitor Technical Data TD150021E Power Xpert ranch ircuit Monitor Introduction The Power Xpert ranch ircuit Monitor (PX M) meter module strip provides SI 12.20 0.5% revenue class branch circuit metering in panelboard

More information

Specifications: Air Driven Tube Cutter P S RTM. (805)

Specifications: Air Driven Tube Cutter P S RTM.  (805) Specifications: ir riven Tube utter The NEW 000 The new 000 lever actuated cutter was developed by PSR to internally cut non-ferrous and ferrous tubes within condensers, chillers and similar vessels with

More information

(n1.43 [36]) (n1.31 [33]) (0.69 [18])

(n1.43 [36]) (n1.31 [33]) (0.69 [18]) REV PPROVED INITIL RELESE //6 MP D D (n. [6]) (n. []) (.8 [8]) (0.69 [8]) NEOPRENE WSHER /8-8 UNEF- THRED SUPPLIER PRINT EPTNE: [ ] ccept drawing/specification: No changes needed: [ ] This part is RoHS

More information

A23 ECR SEP2017 WW RR A24 ECR MAY2018 KD FL N#0.30

A23 ECR SEP2017 WW RR A24 ECR MAY2018 KD FL N#0.30 THIS RWING IS UNPULISHE. OPYRIGHT 0 Y RELESE FOR PULITION LL RIGHTS RESERVE. 0 LO IST ES 00 P LTR ESRIPTION TE WN PV ER0 SEP0 WW RR ER00 0MY0 K FL N#0.0 M#0.0 NOTE HOUSING HS RST OMPLINT KEYING, LTHING,

More information

Polar PDUs POWER MANAGEMENT

Polar PDUs POWER MANAGEMENT Polar Power Distribution Units (PDUs) provide the ultimate solution for combining cabinet level power management, environmental monitoring, and cabinet access control in multi-tenant and enterprise data

More information

A & LIFT BASE INFORMATION HEIGHT DIM A MM [INCH]

A & LIFT BASE INFORMATION HEIGHT DIM A MM [INCH] 9 [ ] 9 [ ] 0 [ 9 ] [ ] 0 [ 9 ] [ ] 9 [ ] 9 [ ] LTERNTOR EN [ ] RITOR EN X 09 [ 9. ] X [ 9. ] FIXE IR INTKE LOUVER (STNR) X [ 0.0 ] OUTLET SILENER 0 [ ] [ 9 ] OOR REMOVE 0 [ 9 ] INTKE ESS 9 [ ] [ 0 ] 9

More information

Switched, Outlet Level Monitoring

Switched, Outlet Level Monitoring Part Number Power Configuration Physical Configuration RCURN082-102D20TL5-OD Switched, Outlet Level Monitoring 20A, 120V, 1.9kW 19in / 483mm Horizontal Description The RCURN082-102D20TL5-OD provides hands-on

More information

w. linear performance warranty. Safer Solar Panel-level disconnect to remotely deactivate modules Arc, fire and safety hazard mitigation

w. linear performance warranty. Safer Solar Panel-level disconnect to remotely deactivate modules Arc, fire and safety hazard mitigation Mono Multi Solutions The Optimized Solution OMPTILE WITH MOST TRIN MOULES Safer Solar Panel-level disconnect to remotely deactivate modules rc, fire and safety hazard mitigation 50-75 w POWER OUTPUT range

More information

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R APC Metered Rack PDU, Input: 120V, Input Connections: NEMA L5-20P, Cord Length: 10 feet ( 3.05 meters ), Output: 120V, Output Connections:

More information

LITESPEED. A comprehensive selection of our most popular LED products. 10 Day Quick Ship Program

LITESPEED. A comprehensive selection of our most popular LED products. 10 Day Quick Ship Program LITESPEE comprehensive selection of our most popular LE products. 0 ay Quick Ship Program PERIMETER/REESSE SLOT URVE RETILINER PROGRM RULES LITESPEE Shipment within 0 business days from receipt of released,

More information

Chapter. Specifications. In this Chapter...

Chapter. Specifications. In this Chapter... Specifications hapter In this hapter... vailable Models... - E-SML-RN and E-SML-R Specifications... - E-SML and E-TL Specifications... - E-TL, E-TL and E-TL Specifications... - E-SML-RN, E-SML-R, E-SML

More information

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial SmartOnline 100-127V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial MODEL NUMBER: SU3000RTXLCD3U Description Tripp Lite Smart Online UPS systems

More information

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13 Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13 APC Metered Rack PDU, Input: 230V, Input Connections: IEC-320 C14, Cord Length: 10 feet ( 3.05 meters ), Output: 230V, Output Connections:

More information

SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Pre-installed WEBCARDLX Network Interface, USB, DB9 Serial

SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Pre-installed WEBCARDLX Network Interface, USB, DB9 Serial SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Pre-installed WEBCARDLX Network Interface, USB, DB9 Serial MODEL NUMBER: SU1500RTXL2UN Highlights 1500VA / 1.5kVA / 1200

More information

SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial

SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial MODEL NUMBER: SU3000RTXL3UHV Highlights 3000VA / 3kVA / 2400 watt on-line double-conversion

More information

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord APC Metered Rack PDU, Input: 208V 3PH, Input Connections: Hubbell CS8365C, Cord Length: 10 feet ( 3.05 meters ), Output:

More information

MULTIPORT SERVICE TERMINALS (MST)

MULTIPORT SERVICE TERMINALS (MST) MULTIPORT SERVIE TERMINLS (MST) s (TE) FTTX infrastructure solutions are designed from the ground up to meet the unique requirements of FTTX networks. esigned for operational efficiency and scalability,

More information

Data Center Power: Managing for Energy Efficiency and Cost Savings

Data Center Power: Managing for Energy Efficiency and Cost Savings Data Center Power: Managing for Energy Efficiency and Cost Savings White Paper STI-100-013 November 2013 HEADQUARTERS - NORTH AMERICA Server Technology, Inc. 1040 Sandhill Drive Reno, NV 89521 United States

More information

CENTER/REVERSED OUTER ,

CENTER/REVERSED OUTER , 8 THIS RWING IS UNPULISHE. OPYRIGHT RELESE FOR PULITION Y LO IST GP LL RIGHTS RESERVE. 00 P LTR GE SSEMLY GSKET FLNGE EMI GSKET. ONTT HIKLET HIKLET LIGNMENT LIP SLE EMI SPRINGS REVISE PER EO0089 0UG PP

More information

ES 00 NTS 1 5 A7 RAST 2.5 TAB HEADER ASSY TH, VERTICAL, EXTERNAL LOCKING

ES 00 NTS 1 5 A7 RAST 2.5 TAB HEADER ASSY TH, VERTICAL, EXTERNAL LOCKING 2 THIS RWING IS UNPULISHE. OPYRIGHT 2 Y RELESE FOR PULITION LL RIGHTS RESERVE. 2 LO IST ES P LTR ESRIPTION TE WN PV ER2 JUN2 M.T YH.M.2 2. ER NOV2 GRZ T ER MY2 WW RR NOTE SEE SHEET FOR VILLE ONFIGURTIONS

More information

RCOBN PH6TL21-D Power Monitoring, Outlet Level. Part Number

RCOBN PH6TL21-D Power Monitoring, Outlet Level. Part Number Part Number Power Configuration Physical Configuration RCOBN248-102PH6TL21-D Power Monitoring, Outlet Level 20A, 120/208V WYE, 5.7kW 66 in Vertical Description RCOBN248-102PH6TL21-D provides site managers

More information

UPS Series. features: uninterruptible power supply. what great systems are built on.

UPS Series. features: uninterruptible power supply. what great systems are built on. uninterruptible power supply uninterruptible power supply with energy saver design that is optimized to address the needs of A/V systems features: Pure Sine Wave technology with Automatic Voltage Regulation

More information

G GRCOW PH6PS6-D-IP44 Power Monitoring, Outlet Level. Part Number

G GRCOW PH6PS6-D-IP44 Power Monitoring, Outlet Level. Part Number Part Number Power Configuration Physical Configuration G1306 -- GRCOW246-103PH6PS6-D-IP44 Power Monitoring, Outlet Level 32A,, 7.3kW 72 in / 1829 mm Vertical Description G1306 -- GRCOW246-103PH6PS6-D-IP44

More information

Innovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s

Innovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s Structure Source PDU s Innovative Power Engineering High Quality Power Distribution for the Data Centre structure source Making the complex, simple structure source product range Rack and Server Power

More information

Chapter. Specifications - Terminal Bases and Power Supplies. In This Chapter:

Chapter. Specifications - Terminal Bases and Power Supplies. In This Chapter: Specifications - hapter Terminal ases and Power Supplies In This hapter: TK-0(-) I/O Terminal ase... TK-(-) I/O Terminal ase... TK-0, TK-0 Power Supply... alculating the Power udget... Managing the Power

More information

Solutions Guide for Cisco UCS B and C Series Servers

Solutions Guide for Cisco UCS B and C Series Servers Solutions Guide for Cisco UCS B and C Series Servers The Cisco Unified Computing System is a next-generation data center platform that unites compute, network, storage access, and virtualization into a

More information

Bulletin 1494H Heavy Duty Safety Switches

Bulletin 1494H Heavy Duty Safety Switches ulletin H Heavy uty Safety isconnect Switches Product Overview/Product Selection Fusible and Non-Fusible Type ulletin H Heavy uty Safety Switches switch ratings Type, R, or enclosures V: -phase, -phase,

More information

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack, LCD display, USB, DB9 Serial

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack, LCD display, USB, DB9 Serial SmartOnline 100-127V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack, LCD display, USB, DB9 Serial MODEL NUMBER: SU3000RTXLCD2U Description Tripp Lite Smart Online UPS systems

More information

PRELIMINARY ISOMETRIC VIEW SCALE 8: ISOMETRIC VIEW SCALE 8: ISOMETRIC VIEW SCALE 8:1 GASKET FLANGE EXTERNAL

PRELIMINARY ISOMETRIC VIEW SCALE 8: ISOMETRIC VIEW SCALE 8: ISOMETRIC VIEW SCALE 8:1 GASKET FLANGE EXTERNAL THIS RWING IS UNPULISHE. OPYRIGHT Y RELESE FOR PULITION LL RIGHTS RESERVE. P LTR ESRIPTION TE WN PV 4 REVISE 04UG JV E TOP GE EXTERNL EMI GSKET GSKET FLNGE UPTE VIEWS 9SEP JV E UPTE VIEWS 0FE JV E UPTE

More information

550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure

550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure 550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure MODEL NUMBER: AV550SC Highlights 4 AC outlets (including 1 delayon outlet for router) Automatic recycle/reset

More information

SmartOnline 6kVA On-Line Double-Conversion UPS, 6U Rack/Tower, V Hardwire output

SmartOnline 6kVA On-Line Double-Conversion UPS, 6U Rack/Tower, V Hardwire output SmartOnline 6kVA On-Line Double-Conversion UPS, 6U Rack/Tower, 200-240V Hardwire output MODEL NUMBER: SU6000RT3UHVXL Highlights 6000VA / 6kVA / 4200W on-line double-conversion UPS 200/208/220/230/240V

More information

Power Distribution Units for Data Centers

Power Distribution Units for Data Centers WWW.SIEMON.COM Power Distribution Units for Data Centers PowerMax Power Distribution Units Siemon s PowerMax line of PDUs range from basic and metered for simple, reliable and cost-effective power distribution,

More information

PREDATOR HD. Product Brochure. Dual lamp unit shown (covers SIR250SW, 250SWL and SIR275 products), other colours available.

PREDATOR HD. Product Brochure. Dual lamp unit shown (covers SIR250SW, 250SWL and SIR275 products), other colours available. PRETOR H Product rochure ual lamp unit shown (covers SIR50SW, 50SWL and SIR75 products), other colours available. Product rochure PRETOR H IP68 FULL 080P HIGH EFINITION VIEO High Speed High efinition Ruggedised

More information

How do I... If you manage a datacenter, we have a solution for you. Sentry : Cabinet Power Distribution Unit Product Family : Metered CDU.

How do I... If you manage a datacenter, we have a solution for you. Sentry : Cabinet Power Distribution Unit Product Family : Metered CDU. If you manage a datacenter, we have a solution for you. How do I... Distribute power to all the equipment in the cabinet? Distribute and load balance 3-phase power? Monitor True RMS input current? Reboot

More information

Chapter. Accessories. In This Chapter...

Chapter. Accessories. In This Chapter... ccessories hapter In This hapter... ccessories Overview... - / Power dapter... - / Power dapter imensions... - / Power dapter Installation... - -SU -pin to Terminal lock dapters... - Non-glare Screen overs...

More information

SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, SNMPWEBCARD Option, LCD Display, USB, DB9 Serial

SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, SNMPWEBCARD Option, LCD Display, USB, DB9 Serial SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, SNMPWEBCARD Option, LCD Display, USB, DB9 Serial MODEL NUMBER: SMART1500RM2U Highlights 1500VA / 1.5kVA / 1350W line interactive

More information

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview Overview You cannot control what you cannot monitor. The new brings state of the art management and control to rack mounted power distribution units (PDU) to prevent over provisioning of power from restricting

More information

SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module

SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module MODEL NUMBER: SV20KS1P0B Highlights Scalable capacity up

More information

POWER DISTRIBUTION UNITS (PDUs)

POWER DISTRIBUTION UNITS (PDUs) P R O D U C T D ATA S H E E T POWER DISTRIBUTION UNITS (s) for CPI Rack and Cabinet Systems K E Y F E AT U R E S Distribute power to multiple devices from a single power connection NEMA, California Style

More information

POWER DISTRIBUTION UNITS

POWER DISTRIBUTION UNITS POWER DISTRIBUTION UNITS Efficient and safe power distribution for information systems and datacenters POWER DISTRIBUTION UNITS > THE SOLUTION Power distribution units Eurolan s extensive product range

More information

15-80 ka surge protection Hz line frequency <.5 ns response time Available in units noted from 15-1,200 Amps

15-80 ka surge protection Hz line frequency <.5 ns response time Available in units noted from 15-1,200 Amps Series Filters with Transient Voltage Surge Suppression Islatrol Series Two stage, high-frequency noise filter and high-energy current diverter available from 5 mp single phase to 1200 mp three phase.

More information

The -3Ph extension on a product indicates a 3 Phase power product.

The -3Ph extension on a product indicates a 3 Phase power product. Power Terms Glossary 20-Amp Power Input Support: 20-amp Power Input Support. IEC320/C20 power inlet receptacles supports any power cord with IEC320/C19 power connector (PTCORD-XX). 24-Character Outlet

More information

SmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 3U Rack/Tower, Extended Run, WEBCARDLX Network Interface, LCD, USB, DB9

SmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 3U Rack/Tower, Extended Run, WEBCARDLX Network Interface, LCD, USB, DB9 SmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 3U Rack/Tower, Extended Run, WEBCARDLX Network Interface, LCD, USB, DB9 MODEL NUMBER: SU3000RTXLCD3N Highlights Zero transfer time suitable for advanced

More information

HPE Intelligent Power Distribution Unit Installation Instructions

HPE Intelligent Power Distribution Unit Installation Instructions HPE Intelligent Power Distribution Unit Installation Instructions Important safety information For important safety, environmental, and regulatory information, see Safety and Compliance Information for

More information

Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity

Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications AC Power For Business-Critical Continuity Liebert GXT3, 5kVA-10kVA UPS Systems: Big Protection, Small Package Today

More information

NHD WF-ATXI#-T

NHD WF-ATXI#-T NH-7.0-800480WF-TXI#-T TFT (Thin-Film-Transistor) olor Liquid rystal isplay Module NH- Newhaven isplay 7.0-7.0 iagonal 800480-800xRGx480 pixels WF- Model - uilt-in driver / No ontroller T- White LE backlight

More information

E-ACLM-V E-ACLM-P12/8/18 AC LINE MONITORS Installation and Operation Manual

E-ACLM-V E-ACLM-P12/8/18 AC LINE MONITORS Installation and Operation Manual NTI R NETWORK 1275 Danner Dr Tel:330-562-7070 TECHNOLOGIES Aurora, OH 44202 Fax:330-562-1999 INCORPORATED www.networktechinc.com ENVIROMUX Series E-ACLM-V E-ACLM-P12/8/18 AC LINE MONITORS Installation

More information

SmartPro LCD 120V 1500VA 900W Line-Interactive UPS, Extended Run, 2U Rack/Tower, LCD Display, USB, DB9 Serial

SmartPro LCD 120V 1500VA 900W Line-Interactive UPS, Extended Run, 2U Rack/Tower, LCD Display, USB, DB9 Serial SmartPro LCD 120V 1500VA 900W Line-Interactive UPS, Extended Run, 2U Rack/Tower, LCD Display, USB, DB9 Serial MODEL NUMBER: SMART1500LCDXL Highlights 1500VA / 1.5kVA 2U rack/tower 120V line interactive

More information

ANY EQUIVALENT AVIATION GRADE HARDWARE MAY BE USED. Detail A HEAT SHIELD SEE PAGE 5 FOR ASSEMLBY B. Detail B. Detail C A. Detail D

ANY EQUIVALENT AVIATION GRADE HARDWARE MAY BE USED. Detail A HEAT SHIELD SEE PAGE 5 FOR ASSEMLBY B. Detail B. Detail C A. Detail D ISIONS ESRIPTION TE THIS IS ONLY PPLILE TO PFS-0 THIS IS ONLY PPLILE TO POWERFLOW S/N 0, 0 N HIGHER, UNLESS EXHUST HS EEN ONVERTE TO THIS ONFIGURTION. 0 etail HET SHIEL SEE PGE FOR SSEMLY etail 9 0 etail

More information

SmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules

SmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules SmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules MODEL NUMBER: SV40KM2P2B Highlights Scalable capacity up to

More information

PDU Solutions. PDU Solutions

PDU Solutions. PDU Solutions Canovate offers a full range of PDU s from basic and metered ones to IP PDU s with per socket switching capability and wireless sensor connectivity. Our PDU s can be used in the most complex ISP and Colocation

More information

PDU Inspired by Your Data Center. W IEC PDU Series

PDU Inspired by Your Data Center. W IEC PDU Series PDU Inspired by Your Data Center W IEC PDU Series Intelligent kwh PDU - W series Power Efficiency Management With today s increasing demand for high technology power management solutions, PDU kwh measurement

More information

Product Catalog. ATEN NRGence Energy Intelligence PDU

Product Catalog. ATEN NRGence Energy Intelligence PDU Product atalog TEN NRGence Energy Intelligence PDU 2017 2018 Simply etter onnections Our Vision Simply etter onnections has always been at the heart of the TEN brand. It means providing innovative solutions

More information

SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial

SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU16000RT4U Description Tripp Lite 16kVA SmartOnline

More information

Hardwired Uninterruptible Power Supply

Hardwired Uninterruptible Power Supply 96-01160 / rev. 1 / 08-15-11 Hardwired Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Hardwired Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs

More information

TEE-STL BLK 1/2" (SCH 80) TEE-STL BLK 1/2" REGULATOR-TWO STAGE REGULATOR-TWO STAGE

TEE-STL BLK 1/2 (SCH 80) TEE-STL BLK 1/2 REGULATOR-TWO STAGE REGULATOR-TWO STAGE RELESE TE WG 00-0-000 PIPE-STL LK /" (SH 0) ZONE ISION REOR TE FTR-ORIG 00-0-000 TUING-OPPER /" O T- 00-0-000 TEE-STL LK /" (SH 0) 00-0-000 TUING-OPPER /" O T- 00-0-000 TEE-STL LK /" 00-0-000 PIPE-STL

More information

Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection

Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection MODEL NUMBER: AV88SATG Highlights 8 outlets / 8-ft. cord 2880 joule rating Auto/Manual switch offers GREEN

More information

24-Port Gigabit Ethernet Switch w/ 12 Outlet PDU, 2 SFP and 8 PoE+ Ports, 120W

24-Port Gigabit Ethernet Switch w/ 12 Outlet PDU, 2 SFP and 8 PoE+ Ports, 120W Cat6A cables, such as Tripp Lite's N261-Series, are recommended for optimal performance 24-Port Gigabit Ethernet Switch w/ 12 Outlet PDU, 2 SFP and 8 PoE+ Ports, 120W MODEL NUMBER: NSU-G24C2P08 Description

More information

VITUS 32. Large Industrial Solution. Features. Industrial Panel PC in metal cased

VITUS 32. Large Industrial Solution. Features. Industrial Panel PC in metal cased Large Industrial Solution Industrial Panel P in metal cased VITUS 32 Intel ore i3/i5/i7 Mobile Features - E F G H Power Keylock US Gigabit LN VI- VI- OM VG Industrial Panel P in metal cased isplay L TFT

More information

Server Technology, Inc.

Server Technology, Inc. Server Technology, Inc. Planning, Implementing and Application of Cabinet Power Distribution Units White Paper STI-100-007 Headquarters Server Technology, Inc. 1040 Sandhill Drive Reno, NV 89521 United

More information

Application. Contents of Package. Inspect the CyberSwitch upon receipt. The package should contain the following items:

Application. Contents of Package. Inspect the CyberSwitch upon receipt. The package should contain the following items: Overview CyberPower power manager CyberSwitch is the ultimate power control center to manage multiple network devices via the Internet. After installing the hardware and setting up an IP address, this

More information

Protect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11

Protect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11 Protect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11 MODEL NUMBER: SUPER7TEL Highlights 7 outlets / 7-ft. cord 2520 joule rating Modem/fax surge protection $75,000

More information

SmartOnline V 1kVA 800W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartOnline V 1kVA 800W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial SmartOnline 100-120V 1kVA 800W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU1000RTXL2UA Highlights 1000VA / 1kVA / 800 watt on-line double-conversion

More information

OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES

OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES www.unipowerco.com Manual No. PDUAC1USM-2 pduac1us-man-rev2-0115.indd 2015 UNIPOWER LLC All Rights Reserved NORTH AMERICA 3900 Coral Ridge Drive,

More information

SmartOnline 120V 1kVA 900W Double- Conversion UPS, 2U, Extended Run, Network Card Options, LCD display, USB, DB9 Serial

SmartOnline 120V 1kVA 900W Double- Conversion UPS, 2U, Extended Run, Network Card Options, LCD display, USB, DB9 Serial SmartOnline 120V 1kVA 900W Double- Conversion UPS, 2U, Extended Run, Network Card Options, LCD display, USB, DB9 Serial MODEL NUMBER: SU1000RTXLCD2U Highlights 1000VA / 1kVA / 900W on-line double-conversion

More information

NOTES UNLESS OTHERWSE SPEIFIE,. 0.00 E N. 0.00 NILOX FE MX PRINT WITH =.. 0.00 E N ITEM ESRIPTION PRT NUMER QTY. UOM NOTES SSY, HMER, V. HiFlow 90SYSS E. SSEMLY ROSS SHFT 90SYSS E. METRI IR YLINER, RHS

More information

SmartPro 120V 1.05kVA 705W Line-Interactive UPS, Tower, 120V, USB port

SmartPro 120V 1.05kVA 705W Line-Interactive UPS, Tower, 120V, USB port SmartPro 120V 1.05kVA 705W Line-Interactive UPS, Tower, 120V, USB port MODEL NUMBER: SMART1050 Highlights 1.05kVA / 1050VA line interactive tower UPS system 120V output, Corrects brownouts and overvoltages

More information

Q-LINK SMART BYPASS. SIZING INFORMATION TABLE Q-Link Variable Frequency Drive - 3-Phase 208 VAC 230 VAC VAC HP FLA HP FLA HP FLA TECHNOLOGIES

Q-LINK SMART BYPASS. SIZING INFORMATION TABLE Q-Link Variable Frequency Drive - 3-Phase 208 VAC 230 VAC VAC HP FLA HP FLA HP FLA TECHNOLOGIES Q-LINK SMRT BYPSS 1 28, 208 480VC, 3Ø UL Type 1 Enclosure The is an integrated solution for critical applications without compromising for communications and motor protection. Unlike traditional bypasses,

More information

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting. UPS operation and display panel can rotate 90 degrees, which provides upright viewing for users. Liebert GXT3 UPS Includes These Outstanding Features: Flexibility: Rack/tower configuration. The versatile

More information

Chapter. Accessories. In this Chapter...

Chapter. Accessories. In this Chapter... ccessories hapter In this hapter... ccessories...- -more Micro Programming Software...- E-EOM Ethernet ommunication Module...- -SU -pin 0-degree ommunication Port dapter...- -SU -pin to Terminal lock dapters...-

More information

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch MODEL NUMBER: SU8000RT4U Description Tripp Lite 8kVA SmartOnline

More information

MODEL NUMBER: B IP4

MODEL NUMBER: B IP4 Free NetCommander-AXS Management Software is available for access and control of all of your Tripp Lite NetCommander IP KVM switches (B070 and B072 series). From a single interface, you can access server

More information

SmartOnline V 3kVA 2.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartOnline V 3kVA 2.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial SmartOnline 200-240V 3kVA 2.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SUINT3000RTXL2U Description 3000VA / 3kVA / 2500 watt on-line, double-conversion

More information

Protect It! 7-Outlet Surge Protector, 6-ft. Cord, 1080 Joules, Fax/Modem Protection, RJ11

Protect It! 7-Outlet Surge Protector, 6-ft. Cord, 1080 Joules, Fax/Modem Protection, RJ11 Protect It! 7-Outlet Surge Protector, 6-ft. Cord, 1080 Joules, Fax/Modem Protection, RJ11 MODEL NUMBER: SUPER6TEL Highlights 7 outlets / 6-ft. cord 1080 joule rating Modem/fax surge protection $50,000

More information