HPE Intelligent Power Distribution Unit Installation Instructions
|
|
- Maximilian Wade
- 5 years ago
- Views:
Transcription
1 HPE Intelligent Power Distribution Unit Installation Instructions Important safety information For important safety, environmental, and regulatory information, see Safety and Compliance Information for Server, Storage, Power, Networking, and Rack Products, available at the Hewlett Packard Enterprise website ( oducts). NOTE: The HPE Intelligent Power Distribution Unit (ipdu) is intended for use only with information technology equipment (ITE) loads in racks or similar computer room applications. Extension Bars ship with some kits. These Extension Bars are designed for use with Compaq/HPE Power Distribution Core Units and HPE Uninterruptible Power Systems (UPSs). The Extension Bars can be used with other power sources, provided that the source includes branch circuit overcurrent protection not exceeding 20. WRNING: To reduce the risk of personal injury from electric shock, do not remove the cover. There are no field-serviceable or user-serviceable components inside. WRNING: risk of personal injury from electric shock and hazardous energy levels exists. The installation of options and routine maintenance and service of this product must be performed by individuals who are knowledgeable about the procedures, precautions, and hazards associated with C power products. WRNING: The F900, F901 and F model PDUs must only be used on 240/415 circuits. 240/415 5 W wye power systems are not standardized in North merica and Japan and may be distributed using NEM L22 receptacles normally intended for 277/480 systems. To reduce the risk of fire and electric shock, be certain to connect the 415 models only to a receptacle wired for 240/415. Follow these safety precautions when connecting multiple hardware components to power sources. Copyright 2009, 2016 Hewlett Packard Enterprise Development LP The information contained herein is subject to change without notice. The only warranties for Hewlett Packard Enterprise products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein. Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. WRNING: To reduce the risk of personal injury or damage to the equipment: Plug the input power cord into a grounded (earthed) electrical outlet that is located near the equipment and is easily accessible. Be sure that the load products connected to the Intelligent Power Distribution Unit (ipdu) are adjusted for, or otherwise capable of operation from the same line voltage supplying the ipdu. Failure to verify the voltage can lead to severe equipment damage. Do not overload the ipdu. The total input current of all equipment connected to each output cannot exceed the total output marked on the ipdu. Part Number: February 2016 Edition: 6
2 WRNING: To reduce the risk of personal injury from high-leakage current, verify earth connection before connecting the power supply. The summation of input power for multiple pieces of information technology equipment through the use of power products can result in high-leakage currents. If the total system leakage current for a system of components exceeds 3.5 m: The use of a detachable input power cord is prohibited. The input power cord must be securely attached, and it should be connected to the C mains by hardwiring or through the use of a non-residential, industrial-style plug that maintains positive earth connection. If the total system leakage current through the ground conductor exceeds 5% of the input current per line under normal ope conditions, the system loads should be divided among multiple power connections. Core Unit features Flexible mounting in 0U, 1U, or 2U configurations (depending on your, maximizing rack space (no additional parts are required for mounting) Overcurrent and short-circuit protection for each output (UL-489-listed circuit breakers) outlets to power Extension Bars, Intelligent Extension Bars, or other C20 plug-compatible equipment Easy identification and reset of overload circuits (circuit breakers move to Off position), minimizing downtime Power cord retention Recessed circuit breaker handles to prevent inadvertent power-off Core Unit components Overview These installation instructions are provided to assist qualified personnel with the installation of the Intelligent Power Distribution Unit (ipdu). IMPORTNT: The appearance of the ipdu might vary depending on the specific unit installed. The input voltage of a single ipdu is 200 to 240 C. The input voltage of a three ipdu is 200 to 240 C or 380 to 415 C, depending on the model. For more information about any of the topics covered in this document, and for safety information and regulatory notices, see the Intelligent Power Distribution Unit User Guide on the Hewlett Packard Enterprise website ( ipdu components Callout Description 1 Display Module 2 Core Unit 3 Extension Bar 4 Intelligent Extension Bar Callout Description 1 Circuit breaker for load segment 1 ( if 2 Circuit breaker for load segment 2 ( B if 3 Circuit breaker for load segment 3 ( C if 3 4 Circuit breaker for load segment 4 ( if 5 Circuit breaker for load segment 5 ( B if 6 Circuit breaker for load segment 6 ( C if 3 7 Serial connector for additional ipdu connection 8 Serial connector for Display Module connection 9 Network connector 10 Reset button* 11 outlet for load equipment power or Extension Bar attachment (load segment 6, C 12 outlet for load equipment power or Extension Bar attachment (load segment 5, B 13 outlet for load equipment power or Extension Bar attachment (load segment 4,
3 Callout Description 14 outlet for load equipment power or Extension Bar attachment (load segment 3, C 15 outlet for load equipment power or Extension Bar attachment (load segment 2, B 16 outlet for load equipment power or Extension Bar attachment (load segment 1, *When you press the Reset button, power to the outlets is maintained. Management functionality is momentarily lost while the components reset. 12-outlet Core Unit components Callout Description 1 Circuit breaker for load segment 7 ( if 2 Circuit breaker for load segment 8 ( B if 3 Circuit breaker for load segment 9 ( C if 3 4 Circuit breaker for load segment 10 ( if 3 5 Circuit breaker for load segment 11 ( B if 3 6 Circuit breaker for load segment 12 ( C if 3 7 Circuit breaker for load segment 1 ( if 8 Circuit breaker for load segment 2 ( B if 9 Circuit breaker for load segment 3 ( C if 3 10 Circuit breaker for load segment 4 ( if 11 Circuit breaker for load segment 5 ( B if 12 Circuit breaker for load segment 6 ( C if 3 13 outlet for load equipment power or Extension Bar attachment (load segment 12, C Callout Description 14 outlet for load equipment power or Extension Bar attachment (load segment 11, B 15 outlet for load equipment power or Extension Bar attachment (load segment 10, 16 outlet for load equipment power or Extension Bar attachment (load segment 9, C 17 outlet for load equipment power or Extension Bar attachment (load segment 8, B 18 outlet for load equipment power or Extension Bar attachment (load segment 7, 19 outlet for load equipment power or Extension Bar attachment (load segment 6, C 20 outlet for load equipment power or Extension Bar attachment (load segment 5, B 21 outlet for load equipment power or Extension Bar attachment (load segment 4, 22 outlet for load equipment power or Extension Bar attachment (load segment 3, C 23 outlet for load equipment power or Extension Bar attachment (load segment 2, B 24 outlet for load equipment power or Extension Bar attachment (load segment 1, 25 Reset button* 26 Network connector 27 Serial connector for Display Module connection *When you press the Reset button, power to the outlets is maintained. Management functionality is lost momentarily while the components reset. Display Module features Two-digit LED display that shows the current in each ipdu, load segment/extension Bar, or Intelligent Extension Bar outlet in tenths Three scroll buttons to scroll through values Two interior LEDs, which indicate power and alarms One exterior LED, which indicates normal operation During normal conditions, all ipdu component LEDs illuminate green. The blue UID illuminates on the Extension Bars to indicate which component corresponds to the current that appears on the Display Module.
4 Display Module components Intelligent Extension Bar components The total of the Intelligent Extension Bar is. Callout Description 1 LED numeric display for amperage of load segments/extension Bars and Intelligent Extension Bar outlets 2 LED numeric display for PDU current selection (display corresponds to PDU current) 3 LED numeric display for load segment/extension Bar current selection (display corresponds to load segment/extension Bar current) 4 LED numeric display for Intelligent Extension Bar outlet current selection (display corresponds to Intelligent Extension Bar outlet current) 5 Scroll button for Intelligent Extension Bar outlet current selection display (Outlet) 6 Scroll button for load segment/extension Bar current selection display (Ext Bar) 7 Scroll button for PDU current selection display (PDU) 8 Serial port for host computer connection 9 Serial port for Core Unit connection 10 Reset button* 11 larm LED 12 Power LED *When you press the Reset button, power to the outlets is maintained. Management functionality is momentarily lost while the components reset. Intelligent extension bar features (if included) Multiple power outlets, conveniently located for quick and easy equipment power connections Green power indicator for the Intelligent Extension Bar and each individual outlet Blue UID indicator for the component that corresponds to the current that appears on the ipdu Display Module Manual on/off control for each Intelligent Extension Bar, outlet, and outlet UID using the ipdu web interface ttached 2.4-m (8-ft) input power cords Callout Description 1 Row of green power indicators (one for each outlet) 2 Row of blue UID indicators (one for each outlet) 3 Row of five managed 10, C13 outlets 4 Row of outlet number identification labels (one for each outlet) Regardless of the installation orientation, the outlet closest to the top of the rack is always outlet number 1.* 5 Reset button** 6 Green power indicator for the Intelligent Extension Bar 7 Blue UID indicator for the Intelligent Extension Bar Not shown 2.4-m (8-ft) input power cord *If you change the orientation while the Intelligent Extension Bar is powered, you must press the extension bar's Reset button to apply the new outlet configuration. **When you press the Reset button, power to the managed outlets is maintained. Management functionality is momentarily lost while the Intelligent Extension Bar resets. Extension Bar features (if included) Multiple power outlets, conveniently located for quick and easy equipment power connections Green power indicator Blue UID indicator that illuminates when the Extension Bar current appears on the ipdu Display Module Manual on/off control for each Extension Bar UID using the ipdu web interface ttached 2.4-m (8-ft) input power cords Power cord retention Power cord retention
5 Extension Bar components The total of the Extension Bar is. Display Module (1) Serial cable (1) Core Unit cord retention bracket (1) Tie wraps Hardware mounting screws Extension Bar hardware (if included) This kit might contain extra pieces of hardware for your convenience. Callout Description 1 Five 10, C13 outlets 2 Green power indicator 3 Blue UID indicator m (8-ft) input power cord Kit contents Core Unit hardware 6-Outlet Core Unit: This document 0U mounting brackets (2) 1U mounting brackets (2) Display Module (1) Serial cable (2) Core Unit cord retention bracket (1) Tie wraps Hardware mounting screws 6-Outlet Core Unit with Extension Bars: This document 0U mounting brackets (2) 1U mounting brackets (2) Display Module (1) Serial cable (2) Core Unit cord retention bracket (1) Power cord retention brackets (4) Power cord retention bands Tie wraps Extension Bar hardware Hardware mounting screws 12-Outlet Core Unit: This document 2U mounting brackets (2) Model F531 F532 F534 INTL Number of Extension Bars Required tools Number of brackets Number of Extension Bar power cord retention bands Number of Core Unit tie wraps Phillips screwdriver T-25 Torx driver Cage nut insertion tool (included with your original rack hardware)
6 Installing the Core Unit Installing the Core Unit cord retention bracket The Core Unit cord retention bracket is shown for clarification in the following diagram, though installation of the Core Unit cord retention bracket is optional. Installing the 1U or 2U brackets The rack ears are reversible, so the ipdu can be installed with either the circuit breakers or the power cords facing forward. Two ipdus can be mounted in either a 1U or 2U configuration by mounting one ipdu in the front of the rack and the other ipdu in the rear of the rack. Installing the 0U brackets
7 Installing the Core Unit in the rack The Core Unit can be mounted in the rack two different ways, depending on whether you install the 0U brackets () or the 1U brackets (B) on the Core Unit. Installing the 1U or 2U Core Unit in a square-hole rail NOTE: Use the M6 screws and cage nuts that shipped with the rack when installing in a square-holed rail.
8 Installing the 0U Core Unit 3. ttach the provided screws through the holes on the perforated door. 4. Connect the serial cable to the serial connector on the Core Unit. Installing the Intelligent Extension Bars (if included) Intelligent extension bars are 5U in height and provide five outlets in a 5U space. IMPORTNT: Regardless of the installation orientation, the outlet closest to the top of the rack is always outlet number 1. If you change the orientation after initial installation, you must press the Reset button to apply the new outlet configuration. Installing the Display Module 1. Connect the serial cable to the PDU serial connector on the Display Module. 2. Install the Display Module on the inside of the rack door.
9 Installation of the cord retention bracket is optional. Installing the Extension Bars using a single configuration (if included) Extension bars are 5U in height and provide five outlets in a 5U space.
10 The cord retention bracket (1) is shown for clarification in the following diagram, though installation of the cord retention bracket is optional. The cord retention brackets (1) are shown for clarification in the following diagram, though installation of the cord retention brackets is optional. Installing the Extension Bars using a double configuration (if included) The double extension bar configuration provides ten outlets in a 5U space.
11 Connecting the ground bonding cable The ground bonding screw is provided as an attachment point for conductors. Use a ground bonding cable if the rack contains any conductors for the purpose of functional grounding or bonding of ungrounded metal parts. The ground bonding cable is not included in this kit. Connecting devices When connecting devices, distribute the loads evenly across the to remain within the capability of the Extension Bars and Core Unit. Do not overload the ipdu. The total current of all equipment connected to each output cannot exceed the total output marked on the ipdu. Connecting the ipdu to the power source WRNING: To prevent injury from electric shock or damage to the equipment: Plug the input line cord into a grounded (earthed) electrical outlet that is installed near the equipment and is easily accessible. Do not disable the grounding plug on the input line cord. The grounding plug is an important safety feature. Do not use extension cords. Connect the ipdu to a grounded utility power outlet. The C branch circuit overcurrent protection should be sized according to the standard of the plug configuration on each model. The maximum overcurrent for each model is listed in "Connecting devices ("Connecting the ipdu to the power source" on page 11)." Core Unit F520 F521 F522 F533 F523 F525 INTL Input of Core Unit 24 Single 40 Single Single Max branch circuit breaker Individual outlet and style per 50 per 60 per 32 circuit breaker oltage F526 INTL per F527 INTL per F F F538 INTL
12 Core Unit F900 N F901 N F902 N Input of Core Unit Max branch circuit breaker 20 per 30 per 30 per Individual outlet and style circuit breaker *For ipdus, each is defined as follows: Phase segments 1, 4, 7, and 10 Phase B segments 2, 5, 8, and 11 Phase C segments 3, 6, 9, and 12 oltage Server spatial ordering can be achieved by connecting the Intelligent Extension Bars numbering from the bottom of the rack. Insight Control power management v6.2 draws the servers in order based on this best practice so that only minimal arrangement is needed to place the servers in the actual U position in the rack. Extension Bar Total of Extension Bar Outlet style F528 C13 F547 Intelligent C13 Individual outlet 10 No 10 Yes Outlet monitor and control Extension Description Bar for ipdu -1 Power Feed Segment 1-2 Power Feed Segment 2-3 Power Feed Segment 3 Extension Description Bar for ipdu B B-1 Power Feed B Segment 1 B-2 Power Feed B Segment 2 B-3 Power Feed B Segment 3
13 Extension Description Bar for ipdu -4 Power Feed Segment 4-5 Power Feed Segment 5-6 Power Feed Segment 6 Extension Description Bar for ipdu B B-4 Power Feed B Segment 4 B-5 Power Feed B Segment 5 B-6 Power Feed B Segment 6 Checking the Display Module LED indicator Check that the LED indicator that is visible when the rack door is closed (1) illuminates or flashes. iewing current on the Display Module To view the current of ipdu components: 1. Press the Display Module button that corresponds to the component. o PDU Scrolls through the PDUs in the ipdu installation. For the 12-Outlet ipdu, the display shows: U Upper ipdu L Lower ipdu o LS Scrolls through the ipdu load segments/extension Bars in the ipdu installation. o Outlet Scrolls through the Intelligent Extension Bar outlets in the ipdu installation. On the 12-Outlet ipdu, outlets U1-6 correspond to outlets L7-12. The current selection displays in the LED numeric display above the corresponding button. NOTE: When a load segment has an Intelligent Extension Bar attached, the mps numeric LED display alternates between the load segment value and the outlet value. The Outlet numeric LED display simultaneously alternates between the outlet number and "-" to indicate the load segment total current. 2. Continue to press the button to scroll through the components until the display shows the desired current selection. The blue UID indicator illuminates on the Extension Bar or Intelligent Extension Bar outlet to indicate which current is displayed. Launching a terminal emulation program Connecting a host computer Connect a serial cable between the PC serial connector on the Display Module and the serial connector on a host computer. This connection is used to configure and access the ipdu through a terminal emulation program, as well as to upgrade the ipdu. CUTION: You cannot bypass the Display Module and connect a host computer directly to the ipdu. The host computer must be connected to the Display Module to ensure proper communication with the ipdu. Connecting the network cable Connect a standard Ethernet cable between the network connector on the Core Unit and a network jack. This connection is used to access the ipdu through telnet or the web interface. Checking the circuit breakers If power to a device is interrupted, check the circuit breakers and reset if necessary. If power is still not restored, contact your Hewlett Packard Enterprise authorized service representative. NOTE: HyperTerminal is the serial communication program provided with Microsoft Windows and is used in this section as an example for setting up a terminal emulation session. If you are using another utility, the steps might be different. 1. Be sure that you have connected a host computer. 2. On the host computer, click Start, and select Programs>ccessories>Communications>HyperTerminal. The Connection Description window appears. 3. Enter a description, select an icon for the connection, and then click OK. The Connect To window appears. 4. Select the serial connector on the host computer to which the serial cable is attached, and then click OK. The COM Properties window appears. 5. Select the following parameter values, and then click OK. o o o o o Bits per second Data bits 8 Parity None Stop bits 1 Flow control None
14 Configuring the ipdu for remote access 1. Be sure that you have connected a network cable to the Core Unit. IMPORTNT: The ipdu has a fixed setting to auto-negotiate the line speed and cannot be forced to a certain speed such as 10 Mbps or 100 Mbps. When connected to a network switch, the switch port must be set to auto-negotiate. uto-negotiation mode is the recommended industry standard setting and the ipdu will negotiate at the highest possible speed up to 100 / Full Duplex if the network switch supports this option. 2. Be sure that you have connected a serial cable to the Display Module and the host computer with an open terminal emulation session. 3. Press the Reset button on either the Display Module or the Core Unit. On the terminal emulation session screen running on the host computer, the POST executes, and the following prompt appears: Press any key in 5 seconds to enter the Service menu. 4. Press a key to enter the HPE Intelligent PDU Service Menu. 5. On the Service Menu, enter 1 at the prompt to select Module Configuration. The Intelligent PDU Main menu appears. Use the Main menu to configure the minimum settings required to access the ipdu remotely using telnet or the web interface. You can configure other settings using this menu in conjunction with a terminal emulation program or a telnet connection. 6. If your network includes a DHCP server, you can reserve the ipdu IP address using the information provided on the MC address label. -or- If your network is not configured with a DHCP server: a. On the Main menu, enter 1 at the prompt to open the Network Configuration submenu. b. Enter 1 at the prompt to open the IPv4 Network Configuration submenu. c. Enter 4 at the prompt, and then change the boot mode to static IP. d. Enter 1 at the prompt, and then enter the IP address of the ipdu. e. Enter 2 at the prompt, and then enter the subnet mask of the ipdu. f. Enter 3 at the prompt, and then enter the default gateway of ipdu. g. Enter 0 at the prompt to return to the Main menu. 7. Configure web access: a. On the Main menu, enter 1 at the prompt to open the Network Configuration submenu. b. Enter 4 at the prompt to open the Web ccess Configuration submenu. c. Use the submenu options to enable or disable web access, and then configure the associated port, if necessary. 8. Configure telnet access: a. On the Main menu, enter 1 at the prompt to open the Network Configuration submenu. b. Enter 3 at the prompt to open the Remote Console Configuration submenu. c. Use the submenu options to enable or disable telnet access, and then configure the associated port, if necessary. 9. Enter 0 at the prompt to return to the Main menu. 10. Enter 0 at the prompt to exit the configuration utility. 11. Enter s at the prompt to save the settings and close the configuration utility. ccessing the web interface CUTION: It is highly recommended that browser access to the ipdu is isolated from outside access using a firewall or isolated network. 1. Launch a supported browser. The browser window appears. 2. In the ddress field (Microsoft Internet Explorer) or the Location field (Mozilla and Firefox), enter: where xxx.xxx.xxx.xxx is the IPv4 or IPv6 address, and port is the HTTPS port. The default port is 443. The log in screen appears. 3. Enter the user name in the User Name field. The default user name is admin. 4. Enter the password in the Password field. The default password is admin. 5. Select the appropriate language in the Language dropdown box. 6. Click Sign In. The HPE Intelligent PDU web interface appears.
HP Intelligent Modular Power Distribution Unit User Guide
HP Intelligent Modular Power Distribution Unit User Guide Part Number 572153-001 March 2010 (First Edition) Copyright 2010 Hewlett-Packard Development Company, L.P. The information contained herein is
More informationHPE Intelligent Power Distribution Unit User Guide
HPE Intelligent Power Distribution Unit User Guide Abstract This document includes installation, configuration, and operation information for the HPE Intelligent Power Distribution Unit. This document
More informationHP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions
HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W
More informationHP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions
HP UPS R/T3000 ERM Installation Instructions Overview The ERM consists of two battery packs in a 2U chassis. The ERM connects directly to a UPS R/T3000 or to another ERM. Up to two ERM units can be connected.
More informationHP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.
HP R/T2200 UPS Installation Instructions Overview The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. For more information about any of the topics covered in this document, see
More informationG5 PDU Installation Guide
G5 PDU Installation Guide 1 Contents Before You Begin... 3 Overview... 3 Important Safety Information... 3 Required Tools... 5 Section 1 Introduction... 6 Classification Overview... 6 Features... 7 Form
More informationQuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview
Overview You cannot control what you cannot monitor. The new brings state of the art management and control to rack mounted power distribution units (PDU) to prevent over provisioning of power from restricting
More informationhp uninterruptible power system r12000 xr models installation instructions
hp uninterruptible power system r000 xr models installation instructions Overview These instructions show how to install an uninterruptible power system (UPS). For detailed information about the UPS, refer
More informationHPE UPS R5000 User Guide
HPE UPS R5000 User Guide Abstract This document includes installation, configuration, and operation information for the HPE UPS R5000. This document is for the person who installs and maintains power products.
More informationSwitched Rack Power Distribution Unit
Switched Rack Power Distribution Unit AS-216-520-30A-L530 Installation and Quick Start Contents Product Description and Inventory...................... 1 AS-216-520-30A-L530....................... 1 Additional
More informationQuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview
Overview You cannot control what you cannot monitor. The new brings state of the art management and control to rack mounted power distribution units (PDU) to prevent over provisioning of power from restricting
More informationRaritan PXE. Quick Setup Guide. Safety Precautions. Before You Begin. Mounting the PXE. Unpacking the PXE. Zero U Size. 1U Size
Raritan PXE Quick Setup Guide Thank you for purchasing the Raritan PXE intelligent power distribution unit (PDU). The intended use of the PXE is distribution of power to information technology equipment
More informationQuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview
Overview You cannot control what you cannot monitor. The new brings state of the art management and control to rack mounted power distribution units (PDU) to prevent over provisioning of power from restricting
More informationInstalling and Managing the Switch
CHAPTER 2 This chapter describes how to install and manage the Cisco SFS 7008 system hardware and contains these sections: Safety, page 2-2 Preparing the Site, page 2-3 Rack-Mounting the Switch, page 2-4
More informationAruba JL311A Cable Guard Installation Instructions
Aruba JL3A Cable Guard Installation Instructions Abstract Use this guide to assist in the basic installation of the Aruba JL3A Cable Guard on select Aruba 8 port switches. *500-97* Part Number: 500-97
More informationInstalling the Cisco Unified Videoconferencing 3545 MCU
CHAPTER 2 Installing the Cisco Unified Videoconferencing 3545 MCU The Cisco Unified Videoconferencing 3545 MCU works together with a Cisco Unified Videoconferencing 3545 EMP Enhanced Media Processor (EMP)
More informationHP LaserJet MFP Analog Fax Accessory 300. Supplemental Information
HP LaserJet MFP Analog Fax Accessory 300 Supplemental Information HP LaserJet MFP Analog Fax Accessory 300 Supplemental Information Copyright Information 2005 Copyright Hewlett-Packard Development Company,
More informationHP Uninterruptible Power Supplies Overview
NOTE: Additional information on these and additional HP UPS products at: http://h18004.www1.hp.com/products/servers/proliantstorage/power-protection/index.html Description HP rack mountable UPSs, designed
More informationQUICK SETUP GUIDE. Raritan PXE. Safety Precautions. Before You Begin. Mounting the PDU. Unpacking the PXE. 1U Size
QUICK SETUP GUIDE Raritan PXE Thank you for purchasing the Raritan PXE intelligent power distribution unit (PDU). The intended use of the PXE is distribution of power to information technology equipment
More informationQuickSpecs. HPE Metered and Switched Power Distribution Units (PDU) Overview
HPE Metered and Switched Power Distribution Units (PDU) Overview Looking for a power distribution unit that meets the demands of high temperature operating environments and provides monitoring and switching
More informationThe power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.
The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings
More informationInstallation RA5112-C-16A-C20. Basic Rack Power Distribution Unit
Installation RA5112-C-16A-C20 Basic Rack Power Distribution Unit Contents Before You Begin........................1 Safety and grounding information..........1 How to Install the Rack PDU...............2
More informationQuickSpecs. HP Remote Monitoring Power Distribution Units. Overview
QuickSpecs Overview (PDU) provide rack level power monitoring over the network. With billing grade accuracy these PDUs are excellent choices for data centers wanting to make the most of circuit capacity
More informationPower Xpert Meter 2000 Gateway Card Kit
Quick Start Guide IL02601011E PXM 2250 PXM 2260 IQ 250 IQ 260 Power Xpert Meter 2000 Gateway Card Kit Table of Contents Remove the Meter From Service.... 2 Disconnect Power Connections, CTs, and Modbus....
More informationQuickSpecs. HPE Standard Series G2 Basic Power Distribution Units (PDU) Overview. Basic, reliable power distribution for your HPE IT solutions
Overview Basic, reliable power distribution for your HPE IT solutions G2 Basic PDUs are designed to work precisely with HPE Infrastructure and Compute solutions and guarantee a compatible fit for use with
More informationHP R/T3000 G2 UPS User Guide
HP R/T3000 G2 UPS User Guide Abstract This document includes installation, configuration, and operation information for the HP R/T3000 G2 UPS. This document is for the person who installs and maintains
More informationQuickSpecs. HPE Basic Power Distribution Units (PDU) Overview
Overview HPE Basic PDUs are designed to provide reliable and cost effective power distribution for your Hewlett Packard Enterprise and non-hewlett Packard Enterprise IT racks. Offering simple 0U and 1U
More informationHP UPS R5500 User Guide
HP UPS R5500 User Guide Part Number 351643-004A September 2007 (Fourth Edition) Copyright 2003, 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without
More informationHPE BladeSystem c3000 Enclosure Quick Setup Instructions
HPE BladeSystem c3000 Enclosure Quick Setup Instructions Part Number: 446990-007 2 Site requirements Select an installation site that meets the detailed installation site requirements described in the
More informationSmartZone Gateway- Enabled M Series Rack PDU
SmartZone Gateway- Enabled M Series Rack PDU User Manual Release 1.0 Issue 1.0 Copyright 2014 Panduit Corp. All rights reserved. No part of this book shall be reproduced, stored in a retrieval system,
More informationQuickSpecs. HP Basic Power Distribution Units (bpdu) Overview
Overview HP Basic PDUs are designed to provide reliable and cost effective power distribution for your HP and non-hp IT racks. Offering simple 0U and 1U installation options, HP Basic PDUs are available
More informationInstallation and Getting Started Guide. HP ProCurve 600/610 External Power Supplies. PoE. Power over Ethernet Devices
Installation and Getting Started Guide HP ProCurve 600/610 External Supplies www.hp.com/go/hpprocurve PoE over Ethernet Devices HP ProCurve 600/610 External Supplies Installation and Getting Started Guide
More informationPower Xpert Meter 2000 Gateway Card Kit
Quick Start Guide IL02601011E Rev. 2 December 2011 PXM 2250 PXM 2260 IQ 250 IQ 260 Power Xpert Meter 2000 Gateway Card Kit Table of Contents Remove the Meter From Service.... 2 Disconnect Power Connections,
More informationSetting Up Your Cisco Unified Videoconferencing 3515 MCU
CHAPTER 2 Setting Up Your Cisco Unified Videoconferencing 3515 MCU This section describes the following topics: Physical Description, page 2-1 Preparing for Installation, page 2-2 Verifying the Package
More informationPower Xpert Meter 2000 Gateway Card Kit
Quick Start Guide IL02601011E PXM 2250 PXM 2260 IQ 250 IQ 260 Power Xpert Meter 2000 Gateway Card Kit Table of Contents Remove the Meter From Service... 2 Disconnect Power Connections, CTs, and Modbus....
More informationCodian IP VCR IP VCR 2200 Series
Codian IP VCR IP VCR 2200 Series Getting Started Codian IP VCR IP VCR 2200 Series Getting Started Copyright Codian 2006. All rights reserved. This Getting Started Guide may not be copied, photocopied,
More informationRetired. Full Rack Vertical PDU Model (Ideal for 36U to 47U racks)
Overview The HP Monitored PDUs allow administrators and facility personnel to monitor current draw directly at the rack and per PDU. HP Monitored PDUs are available in both 1 phase and 3 phase and in single
More informationQuickSpecs. HPE Standard Series G2 Basic Power Distribution Units (PDU) Overview. Basic, reliable power distribution for your HPE IT solutions
Overview Basic, reliable power distribution for your HPE IT solutions G2 Basic PDUs are designed to work precisely with HPE Infrastructure and Compute solutions. Designed for use with HPE Standard, Advanced,
More informationInstalling Cisco RP-Series PDUs
This chapter contains the following sections: Preparing to Install an RP-Series PDU, page 1 Installing a Zero-U PDU, page 1 Installing a 1RU or 2RU PDU, page 7 Preparing to Install an RP-Series PDU Before
More informationHPE FlexNetwork NJ5000 5G PoE+ Walljack Switch(JH237A)
HPE FlexNetwork NJ5000 5G PoE+ Walljack Switch(JH237A) Quick Start Guide 5998-7330R The information in this document is subject to change without notice. Copyright 2016 Hewlett Packard Enterprise Development
More informationPanduit Basic Rack PDU with Local Meter
Panduit Basic Rack PDU with Local Meter User Manual Release 1.0 Issue 1.0 Copyright 2014 Panduit Corp. All rights reserved. No part of this book shall be reproduced, stored in a retrieval system, or transmitted
More informationReplacing the Battery HP t5730 and t5735 Thin Clients
Replacing the Battery HP t5730 and t5735 Thin Clients Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows
More informationInstalling the Cisco SFS 3504 Server Switch
CHAPTER 3 This chapter describes how to mount your Cisco SFS 3504 Server Switch on a rack, boot the Cisco SFS 3504 Server Switch, and configure basic services. For advanced configuration information, see
More informationPanduit Basic Rack PDU
Panduit Basic Rack PDU User Manual Release 1.0 Issue 1.0 Copyright 2014 Panduit Corp. All rights reserved. No part of this book shall be reproduced, stored in a retrieval system, or transmitted by any
More informationHPE UPS Network Module User Guide
HPE UPS Network Module User Guide Abstract This document includes installation, configuration, and operation information for the HPE UPS Network Module. This document is for the person who installs and
More informationFor details on using the LX, access online help from the application, or download help in PDF format from the Support page on Raritan's website.
Dominion LX Quick Setup Guide Thank you for your purchase of the Dominion LX. The LX is the industry's highest quality, most affordable digital KVM (Keyboard, Video, Mouse) switch for your growing SMB
More informationQuickSpecs. HPE Modular Power Distribution Units (Zero-U/1U Modular PDUs) Overview
HPE Modular Power Distribution Units (Zero-U/1U Modular s) Overview HPE Modular s have a unique modular architecture designed specifically for data center customers who want to maximize power distribution
More information* * Agilent Power Distribution Unit (PDU) Installation Guide
Agilent Power Distribution Unit (PDU) Installation Guide For use with Agilent PDU kits and PDU installation kits for Agilent instrument racks June 2008 Edition 7 E0608 *5000-0039* 5000-0039 Notice The
More informationQuickSpecs. HPE G2 Metered Power Distribution Units. Overview HPE G2 Metered Power Distribution Units
Overview Setting new standards for reliable power distribution and metering HPE Advanced Series G2 Metered PDUs are designed to work precisely with HPE Infrastructure and Compute solutions, providing a
More informationDX 32xx and DX 36xx Quick Start
Release 5.2 9 August 2006 Part No. 093-1816-000 Revision 1 Welcome to the Juniper DX 3200 and 3600 series data center application acceleration platforms. This quick start describes how to install a DX
More informationNote: All of PXC data is available on the PX3 support page. Simply visit Support page > Choose a Product > select "PX3." QS Rule.
QUICK SETUP GUIDE Raritan PXC Thank you for purchasing the PXC intelligent power distribution unit (PDU). The intended use of PXC is distribution of power to information technology equipment such as computers
More informationCisco TelePresence Supervisor MSE 8050
Cisco TelePresence Supervisor MSE 8050 Installation Guide 61-0012-09 July 2014 Contents General information 3 About the Cisco TelePresence Supervisor MSE 8050 3 Port and LED location 3 LED behavior 3 Installing
More informationMetered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R
Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R APC Metered Rack PDU, Input: 120V, Input Connections: NEMA L5-20P, Cord Length: 10 feet ( 3.05 meters ), Output: 120V, Output Connections:
More information16Hi HARDWARE INSTALLATION GUIDE
16Hi HRDWRE INSTLLTION GUIDE Table of Contents Section 1 Ratings....................................................................... 3 Section 2 Site Preparation................................................................
More informationDX Application Acceleration Platform Quick Start
DX Application Acceleration Platform Quick Start Release 5.3 22 June 2007 Part No. 093-1816-001 Revision 3 Welcome to the Juniper DX 3200 and 3600 series data center application acceleration platforms.
More informationQuickSpecs. HPE Intelligent Power Distribution Unit (PDU) Overview
Overview You cannot control what you cannot monitor. The new brings state of the art management and control to rack mounted PDUs to prevent over provisioning of power which may restrict growth in your
More informationHP Rackmountable 3 Phase Uninterruptible Power Systems Overview
Overview Crowded data centers and racks filled to capacity with storage devices, monitors, servers communications devices, and other equipment are driving the need for uninterruptible power with increased
More informationUPS R3000 XR Maintenance and Service Guide
UPS R3000 XR Maintenance and Service Guide First Edition (September 2000) Part Number 221891-001 Spare Part Number 223932-001 Compaq Computer Corporation Notice 2000 Compaq Computer Corporation COMPAQ,
More informationHP BIOS Serial Console User Guide. Part Number March 2003 (Second Edition)
HP BIOS Serial Console User Guide Part Number 306147-002 March 2003 (Second Edition) 2003 Hewlett-Packard Development Company, L.P. Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation.
More informationPower distribution solutions for the ProLiant DL580 G2 server
Power distribution solutions for the ProLiant DL580 G2 server Introduction... 2 Symbols in text... 2 Executive summary... 2 Glossary... 2 ProLiant DL580 G2 server power requirements... 3 Power distribution
More informationBroadband Automatic Disconnect Switch. User Manual
Reset/Test Primary/ Primary Broadband Automatic Disconnect Switch User Manual Local Power Remote Pwer Local 63V Fault Secondary Select Secondary 220V Normal 990-1929 09/2004 Introduction Introduction
More informationHP PDU Best Practices
HP PDU Best Practices Abstract... 2 Introduction... 2 Product Highlights... 2 HP PDU Models Available... 2 Modular PDUs... 2 Modular PDUs... 3 Monitored PDUs... 3 HP Modular PDU Advantages... 4 HP Monitored
More informationNGFW Security Management Center Appliance. for Forcepoint Next Generation Firewall Hardware Guide. Revision B
NGFW Security Management Center Appliance for Forcepoint Next Generation Firewall Hardware Guide Revision B Contents Introduction on page 2 Find product documentation on page 2 Supported software on page
More informationMetered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord
Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord APC Metered Rack PDU, Input: 208V 3PH, Input Connections: NEMA L21-20P, Cord Length: 10 feet ( 3.05 meters ), Output: 208V,
More informationMetered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13
Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13 APC Metered Rack PDU, Input: 230V, Input Connections: IEC-320 C14, Cord Length: 10 feet ( 3.05 meters ), Output: 230V, Output Connections:
More informationQUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!
QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationQuickSpecs. HPE Intelligent Power Distribution Unit (PDU) Overview
Overview You cannot control what you cannot monitor. The new brings state of the art management and control to rack mounted PDUs to prevent over provisioning of power which may restrict growth in your
More informationReadyNAS OS 6 Rack-Mount Hardware Manual
Rack-Mount Hardware Manual Model ReadyNAS 2120 ReadyNAS 2120 v2 ReadyNAS 3130 ReadyNAS 3138 ReadyNAS 3220 ReadyNAS 3312 ReadyNAS 4220 ReadyNAS 4312 ReadyNAS 4360 April 2017 202-11272-08 350 E. Plumeria
More informationInstalling the Cisco MDS 9020 Fabric Switch
CHAPTER 2 This chapter describes how to install the Cisco MDS 9020 Fabric Switch and its components, and it includes the following information: Pre-Installation, page 2-2 Installing the Switch in a Cabinet
More informationSetting Up Your Cisco Unified Videoconferencing 3500 Gateway
CHAPTER 2 Setting Up Your Cisco Unified Videoconferencing 3500 Gateway This section describes the following topics: Physical Description, page 2-1 Preparing for Installation of the Cisco Unified Videoconferencing
More informationNew G2 features allow for greater management of power and environment in IT racks
Overview New G2 features allow for greater management of power and environment in IT racks HPE Enterprise Series G2 Metered and Switched PDUs are designed to work precisely with HPE Infrastructure and
More informationWall-Mounting your HP TouchSmart. User Guide
Wall-Mounting your HP TouchSmart User Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein
More informationQUICK SETUP GUIDE. Raritan PX3 and PX2. Safety Precautions. Before You Begin. Unpacking the PX2/PX3. Zero U Size. 1U and 2U Size
QUICK SETUP GUIDE Raritan PX3 and PX2 Thank you for purchasing the Raritan intelligent power distribution unit (PDU) -- PX3 or PX2. The intended use of PX2/PX3 is distribution of power to information technology
More informationCisco TelePresence Video Communication Server. Getting started
Cisco TelePresence Video Communication Server Getting started D14350.04 November 2010 Contents Contents Contents 2 General information 3 About the Cisco TelePresence Video Communication Server (Cisco VCS)
More information25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA
25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC 309 60A Red 415V, 0U, TAA MODEL NUMBER: PDU3XEVSR6G60B Highlights 25.2kW 240V 3-phase switched 1.8m
More informationManual Version: V1.00. Video Decoder User Manual
Manual Version: V1.00 Video Decoder User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. Copyright Copyright 2016 Zhejiang
More informationLX-1000 Quick Start Instructions E
451-0321E This document is intended to help you get your LX-1000 unit up and running quickly. It includes basic hardware installation, how to obtain IP information, and how to perform a software installation
More informationJuniper Secure Analytics Quick Start Guide
Juniper Secure Analytics Quick Start Guide The instructions in this guide help you connect the Juniper Secure Analytics (JSA) appliance to your network. For details, see the JSA Hardware Guide at http://www.juniper.net/techpubs/en_us/release-independent/jsa/information-products/p
More informationMetered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord
Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord APC Metered Rack PDU, Input: 208V 3PH, Input Connections: Hubbell CS8365C, Cord Length: 10 feet ( 3.05 meters ), Output:
More informationBCM2 Series Branch Circuit Monitors Quick Setup Guide
BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationCHASSIS-1. Form number 7660
VideoBridge Chassis Unit CHASSIS-1 Quick Installation Guide Form number 7660 Table of Contents 1 2 3 4 5 About this Quick Installation Guide...3 Quick Quick Installation Guide...3 Safety...3 Verifying
More informationLiebert MicroPOD 230V
AC Power For Business-Critical Continuity Liebert MicroPOD 230V User Manual TABLE OF CONTENTS 1.0 IMPORTANT SAFETY INSTRUCTIONS...........................................1 2.0 GLOSSARY OF SYMBOLS..................................................2
More informationMcAfee Network Security Platform
NTBA Appliance T-1200 and T-600 Quick Start Guide Revision C McAfee Network Security Platform This guide is a high-level description of how to install and configure McAfee Network Threat Behavior Analysis
More informationCompaq Ultra-Dense Server Deployment in Telecommunications (Telco) Racks
Guidelines June 2000 Prepared by: Storage Products Group Compaq Computer Corporation Contents Introduction...3 Rack Warnings...4 Telco Rack Option Kit for Compaq ProLiant DL360 Server Installation...5
More informationSetting new standards for reliable power distribution and metering
Overview Setting new standards for reliable power distribution and metering HPE G2 Switched PDUs are designed to work precisely with HPE Infrastructure and Compute solutions, providing a highly accurate
More informationQuick start guide for p5 520 ( )
Quick start guide for p5 520 (9111-520) 1 Before you begin This Quick start guide contains an abbreviated set of setup instructions designed to help you quickly unpack and set up a standard system. Users
More informationCisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2
Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,
More informationHP Proliant DL360 G6 Carrier-Grade Server Read Before Install
HP Proliant DL360 G6 Carrier-Grade Server Read Before Install Carrier-Grade Instructions HP Part Number: COOPE-RRTF1 Published: September 2010 Edition: 1 Copyright 2010 Hewlett-Packard Development Company,
More informationMetro-Optical Transport Access Nodes
OnSite 1052 & 1063 Series Metro-Optical Transport Access Nodes Quick Start Guide Important This is a Class A device and isnot intended for use in a residential environment. Part Number: 07MOS10xx-QS, Rev.
More informationHardware overview. Package contents MSM710, documentation, power supply, self-adhesive rubber feet.
In MSM710 Controller Quickstart This Quickstart applies to both the MSM710 Access Controller (J9328A) and the MSM710 Mobility Controller (J9325A). This Quickstart introduces the HP ProCurve Networking
More informationUser Manual. Per Port Monitoring Models
User Manual Per Port Monitoring Models Table of Contents 1. Introduction... 1 2. Package Contents... 2 3. Function... 3 4. Installation... 5 5. Web Interface... 6 1. Introduction The ServerLink Per Port
More informationHPE PSR300-12A & PSR300-12D1
HPE PSR300-12A & PSR300-12D1 Power Supplies User Guide 5998-1604s Part number: 5998-1604s Document version: 6PW103-20160405 Copyright 2015, 2016 Hewlett Packard Enterprise Development LP The information
More informationIBM UPS5000 HV Uninterruptible Power Supply for IBM System x Product Guide
IBM UPS5000 HV Uninterruptible Power Supply for IBM System x Product Guide The IBM UPS5000 HV is a 5 KVA rack-mountable uninterruptible power supply (UPS) that utilizes advanced backup power technology
More informationQUICK SETUP GUIDE. Raritan PX3TS. Safety Precautions. Front View. What's Included
QUICK SETUP GUIDE Raritan PX3TS The PX3TS transfer switch provides AC power to rack IT equipment from one of two AC power sources, and automatically selects which source powers the load based on power
More informationHP 527 Dual Radio ac Unified Wired-WLAN Walljack
HP 527 Dual Radio 802.11ac Unified Wired-WLAN Walljack Installation Guide Part number: 5998-7087a Document version: 6W101-20150318 Legal and notice information Copyright 2015 Hewlett-Packard Development
More informationQUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.
PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA
More informationLatex 110 Printer. Site preparation guide
Latex 110 Printer Site preparation guide 2015 Hewlett-Packard Development Company, L.P. 1st edition Legal notices The information contained herein is subject to change without notice. The only warranties
More informationOPERATIONS MANUAL. n.form I/O Expander (RACK MOUNT) Document Number: Rev B
OPERATIONS MANUAL n.form I/O Expander (RACK MOUNT) Document Number: 200-0009 Rev B table of contents INTRODUCTION FEATURES & CAPABILITIES 1 WIRING General I/O Configuring The System Using The System 4
More informationApplication. Contents of Package. Inspect the CyberSwitch upon receipt. The package should contain the following items:
Overview CyberPower power manager CyberSwitch is the ultimate power control center to manage multiple network devices via the Internet. After installing the hardware and setting up an IP address, this
More informationThis manual describes the installation, setup and operation of this equipment in details.
About This Manual This manual describes the installation, setup and operation of this equipment in details. Please read it carefully to make sure you can operate the multiplexer correctly. Important Avoid
More information