Intelligent-Remote Monitoring (3) Power Circuit Environmental Port (4) Power Outlet Level (5) PDU De-Rated Power Watts (W) PDU Nominal.
|
|
- Brianna Bruce
- 6 years ago
- Views:
Transcription
1 Enclosure Power Distribution Units (PDUs) (continued) PDU Selection: Basic, with ocal Monitoring and Intelligent Highly secure access with admin, control and view-only accounts Intuitive Ethernet-based firmware with alarm or SNMP trap features prevents downtime with early notification of power threshold breaches SNMP (MIB) enabled for compatibility with all leading DCiM packages Integrated environmental monitoring capabilities; monitor temperature, air flow, humidity and dew point via optional connected sensors Internal memory for up to two week of trending of critical parameters for clear understanding of power allocation and usage PDU mounted display option for local current or power monitoring, making phase balancing easier (the PDU itself is not phase balancing) Intelligent PDU Options and Features Remote aggregate, circuit or receptacle power monitoring for granular PUE measurement Switched (on/off) options allow remote outlet management and equipment reboot with sequential delay features; avoid power interruption due to inrush current, equipment start up in desired sequence PDU Firmware, Trending Page Intelligent-Remote Monitoring () Belden PDU ocal Display/ Monitoring Current Basic (B) ocal () Current (C) Power (P) Power (O) Switched (S) () (2) (2) (2) Power Circuit Environmental evel Port (4) Power evel (5) Switched (6) Optional PDU Firmware, Alarm Setting Page tes: () ocal current/amp meter, monitoring at circuit level for multi-circuit PDU. (4) Remote IP-based environmental monitoring, (2) port per PDU. Requires external sensor, refer to accessories (p. 78) for selection. (2) ocal power meter provides Amps, Volts, Watts, Volt-Amps, kwh and Power Factor. (5) Remote IP-based receptacle level monitoring, Amps, Volts, Watts, kwh. () Remote functions (IP-based) accessible via web browser. (6) Remote IP-based receptacle level switching (on/off) with configurable time delay. Intelligent PDU Communication and Environmental Monitoring Ports Power, Cooling and Air Handling Relations Branch Circuit Rating (A) Nameplate Volts (V) Volts Actual Delivered (V) Phase* PDU minal PDU De-Rated Power Watts (W) Power (W) PDU De-Rated Power (kw) PDU De-Rated Power (BTU/hr.) AC Tons** (BTU/00) Air Volume*** ( CFM* kw) , ,400, , ,9.9 6, ,0 2, , ,,28., ,0 4, , ,400 7,280 7., ,480 9, , , ,0, , ,900 5, , ,800, ,69.4, 6 /8 8 7,97 5, , /8 8 0,795 8,66 29, , /8 8 7,992 2, , ,72 48 /8 8 2,66 7, , , /8 8 6,027 28, , , /8 8 45,0 6, , , 50 /8 8 54,040 4, , ,84 6 2/400 2,856, ,69.4, 2/400 2,785 6, ,56 4.7,992 PDU Nameplate Current Rating (A) *-Phase power is calculated by multiplying single phase by the square root of or.7. **Tons of air conditioning required to remove heat from associated IT load. ***The volume of air that is typically required by the IT equipment for each kw of IT load can typically range from 80 to 40 CFM. CFM was used for calculation..800.beden. ( ) 7
2 Single-Phase PDUs Front View 9F-000 Rear View 9F-000 U isted Single-Phase PDUs : B = Basic; = ocal Monitored 9B2-00 De-Rated Amps (A)/ Power (kw) Volts (V) Thermal /Qty Circuit Breaker On-Off Switch Surge Monitoring- Supression ocal Mounting (4) x W x D (in.) 9BF-00 B.4 5/ 5-5P 6 5-5R/6 Rack - 9" 7 x.72 x.75 9BF-002 B.4 5/ 5-5P 6 5-5R/6 Rack - 9" 7 x.72 x.75 9BF-0800 B.4 5/ 5-5P 8 5-5R/8 x.6 x.6 9F / 5-5P 0 5-5R/0 Power Rack - 9" 7 x.72 x 4.5 9BF-400 B.4 5/ 5-5P 4 5-5R/ x.6 x.6 9BG B.9 / 5-P 8 5-R/8 x.6 x.6 9BG-000 B.9 / 5-P 0 5-R/0 Rack - 9" 7 x.72 x.75 9G-000 B.9 / 5-P 0 5-R/0 Power Rack - 9" 7 x.72 x 4.5 9BG-400 B.9 / 5-P 4 5-R/ x.6 x.6 9BG2-400 B.9 / 5-P 4 5-R/ x.6. x.6 9BG-4002 B.9 / 5-P 4 5-R/ x.6. x.6 9BG B.9 / 5-P 4 5-R/ x.6. x.6 9H / 5-P 5-R/ Magnetic Breaker Power 9B /8 6-P 2 C-/2 Magnetic Breaker Power Rack - 9" 7 x.72 x 6.5 9B /8 6-P C-/ + C-9/6 Magnetic Breaker Power tes: () Standard cord length is 0 ft. For other lengths, change dd digit in part # (ex: 9PB2-dd0 would be 9PB2-080 = 8 ft). Available in 2, 4, 6, 8, 0, 5, ft. (2) Standard cord exits from chassis face; top of chassis exit () Standard PDU chassis color is black, custom color overlay Front View 9PG2-000 Rear View 9PG2-000 U isted Single-Phase PDUs : P = Remote Power Monitored; O = Monitored tes: De-Rated Amps (A)/ Power (kw) Volts (V) () Standard cord length is 0 ft. For other lengths, change dd digit in part # (ex: 9PB2-dd0 would be 9PB2-080 = 8 ft). Available in 2, 4, 6, 8, 0, 5, ft. /Qty 9OB2-00 Thermal Circuit Breaker (2) Standard cord exits from chassis face; top of chassis exit () C-, refers to receptacles with locking feature. On-Off Switch Monitoring-ocal/ Remote Environmental Monitoring (4) Standard PDU chassis color is black, custom color overlay (5) These PDUs have no Surge Supression. Mounting (4) x W x D (in.) 9PG2-000 P.9 / 5-P 0 5-R/0 + 0 Magnetic Power/Aggregate - 2 Port Rack - 9" 7 x.72 x 6.5 9PB2-00 P 5 /8 6-P C-/ + C-9/6 Magnetic Breaker Power/Circuit Breaker - 2 Port.25 9PB2-002 P 5 /8 6-P C-/ + C-9/6 Magnetic Breaker Power/Circuit Breaker - 2 Port 72 x 2 x PB P 5 /8 6-P 42 C-/6 + C-9/6 Magnetic Breaker Power/Circuit Breaker - 2 Port 70 x 2 x OB2-00 O 5 /8 6-P C-/8 + C-9/6 Magnetic Breaker Power/Circuit Breaker Port 72 x 2.25 x BEDEN. ( )
3 -Phase PDUs 9I2-00 ZPB8-06IBBPS5 U isted -Phase PDUs : B = Basic; = ocal Monitored De-Rated Amps (A) Power (kw) x Phases Input Volts (V)/ Output Volts (V) /Qty(s) Circuit Breaker MonitoringMounting (Amp/Qty) ocal/remote x W x D (in.) 9I x Ph. /8 WYE/8 2-P C-/ + C-9/6 Amp (X,Y,Z)/ Dog House - 9J2-00 x Ph. /8 WYE/8 2-P C-/ + C-9/6 /D Amp (X,Y,Z)/ Dog House - 9BJ2-00 B x Ph. /8 WYE/ & 8 2-P C-/ + C-9/ + 5-R/6 /D Amp (X,Y,Z)/ Dog House - 9C2-00 x Ph. 2/400 WYE/2 22-P C-/ + C-9/6 Amp (X,Y,Z)/ Dog House - 9C-00 x Ph. 2/400 WYE/2 C-/ + C-9/6 Amp (X,Y,Z)/ Dog House - 9D x Ph. 2/400 WYE/2 22-P C-/ + C-9/6 /D Amp (X,Y,Z)/ Dog House - 9D x Ph. 2/400 WYE/2 C-/ + C-9/6 /D Amp (X,Y,Z)/ Dog House - 9B-200 B 7. x Ph. 8 Delta/8 2 C-9/2 + 0 /6 Breaker/ Rack - 9" 7 x.4 x 9 Dog House - 9B-00 B 7. x Ph. 8 Delta/8 C-/2 + C-9/2 /6 Breaker/ x 2. x.45 Dog House - tes: () Standard cord length is 0 ft. For other lengths, change dd digit in part # (ex: 9PB2-dd0 would be 9PB2-080 = 8 ft). Available in 2, 4, 6, 8, 0, 5, ft. (2) Standard cord exits from chassis face; top of chassis exit () C-, refers to receptacles with locking feature. (4) Ex: /D, D refers to double pole breakers (A in this case). (5) Standard PDU chassis color is black, custom color overlay (6) These PDUs have no Surge Supression or On/Off Switch. (7) PDU Dog House hosts the circuit breaker and protrude from the PDU chassis by.44". 9PC OJ2-00 U isted -Phase PDUs De-Rated Amps (A) Power (kw) x Phases Input Volts (V)/ Output Volts (V) /Qty(s) x Ph. /8 WYE/8 2-P 44 C-/6 + C-9/6 + 5-R/2 Power/X, Y, Z - 2 Port 70 x 2 x 2.25 Dog House - x Ph. /8 WYE/8 2-P C-/ + C-9/6 /D Current/Current Dog House - O x Ph. /8 WYE/8 2-P C-/ + C-9/6 /D Power/X, Y, Z + 72 x 2.25 x Port Dog House - 9OC2-00 O x Ph. 2/400 WYE/2 22-P C-/8 + C-9/6 Power/X, Y, Z Port Dog House - 9OD-00 O 6.6 x Ph. 2/400 WYE/2 C-/8 + C-9/6 /6 Power/X, Y, Z + 72 x 2.25 x Port Dog House - 9P-00 P 7. x Ph. 8 Delta/8 4P, 4W C-/ + C-9/6 /6D 9PC P 5.8 9CJ2-00 C 9OJ2-00 tes: () Standard cord length is 0 ft. For other lengths, change dd digit in part # (ex: 9PB2-dd0 would be 9PB2-080 = 8 ft). Available in 2, 4, 6, 8, 0, 5, ft. (2) Standard cord exits from chassis face; top of chassis exit () C-, refers to receptacles with locking feature. (4) Ex: /D, D refers to double pole breakers (A in this case). (5) Standard PDU chassis color is black, custom color overlay.800.beden. ( ) Circuit Breaker MonitoringEnviron. (Amp/Qty) (4) ocal/remote Monitoring Power/X, Y, Z - 2 Port x W x D (in.) 72 x 2. x.45 Dog House - (6) These PDUs have no Surge Supression or On/Off Switch. (7) PDU Dog House hosts the circuit breaker and protrude from the PDU chassis by.44". (8) All these -Phase PDUs are vertically mounted. 75 : C = Remote Current Monitored; P = Power Monitored; O = Monitored
4 Single- and -Phase PDUs Front View 9SG Rear View 9SG U isted Single- and -Phase PDUs : S = Remotely Switched 9SJ2-00 9SJ2-002 De-Rated Amps (A) Power (kw) x Phases Input Volts (V)/ Output Volts (V) / Circuit Breaker Qty(s) (Amp/Qty) (4) Monitoring-ocal/ Remote Mounting (5) 9SG-0800 S.9 / 5-P 8 5-R/8 Power/Agg Power Rack - 9" 9SG S.9 or. or 8/ or 8 C- 8 C-/8 Power/Agg + Rack - 9" 9SB2-00 S 5 8/8 6-P 9SJ2-00 S x Ph. /8 WYE/8 2-P 9SJ2-002 S x Ph. /8 WYE/8 2-P 9SC-00 S x Ph. 2/400 WYE/2 9SC-002 S x Ph. 2/400 WYE/2 9SC2-00 S x Ph. 2/400 WYE/2 22-P 9SC2-002 S x Ph. 2/400 WYE/2 22-P 9SD-00 S 6.6 x Ph. 2/400 WYE/2 9SD-002 S 6.6 x Ph. 2/400 WYE/2 9SD2-00 S 6.6 x Ph. 2/400 WYE/2 22-P 9SD2-002 S 6.6 x Ph. 2/400 WYE/2 22-P 9S-00 S 7.2 x Ph. 8 Delta/8 9S-002 S 7.2 x Ph. 8 Delta/8 C-/ + C-9/4 C-/8 + C-9/6 C-/8 + C-9/6 C-/2 + C-9/ C-/2 + C-9/ C-/2 + C-9/ C-/2 + C-9/ C-/2 + C-9/ C-/2 + C-9/ C-/2 + C-9/ C-/2 + C-9/ C-/8 + C-9/6 C-/8 + C-9/6 /2D Power/Agg, Circuit, /D Power/Agg, Circuit /D Power/Agg, Circuit, Power/Agg, Circuit Power/Agg, Circuit, Power/Agg, Circuit Power/Agg, Circuit, /6 Power/Agg, Circuit /6 Power/Agg, Circuit, /6 Power/Agg, Circuit /6 Power/Agg, Circuit, /6D Power/Agg, Circuit /6D Power/Agg, Circuit, x W x D (in.) 7 x.72 x 8.5 Dog House - 7 x.72 x 8.5 Dog House - 70 x 2.5 x 2.25 Dog House - 70 x 2.5 x 2.25 Dog House - 70 x 2.5 x 2.25 Dog House - Dog House - Dog House - Dog House - Dog House - Dog House - Dog House - Dog House - Dog House x 4 x.45 Dog House x 4 x.45 Dog House - tes: () Standard cord length is 0 ft. For other lengths, change dd digit in part # (ex: 9PB2-dd0 would be 9PB2-080 = 8 ft). Available in 2, 4, 6, 8, 0, 5, ft. 9SG Power Cord is sold separately. (2) Standard cord exits from chassis face; top of chassis exit () C-, refers to receptacles with locking feature. (4) Ex: /D, D refers to double pole breakers (A in this case). (5) Standard PDU chassis color is black, custom color overlay (6) These PDUs have no On/Off Switch or Surge Supression. (7) PDU Dog House hosts the circuit breaker and protrude from the PDU chassis by.44". (8) All these Single- and -Phase PDUs have a Switched and a 2-port Environmental Monitor BEDEN. ( )
5 PDU Accessories Mounting, Cord Management and Cord Set Description Belden Part Number Tool-ess PDU Mounting Panel (for XM and XS Style Enclosures) XVMP04 XVMP0450 XVMP0480 XVMP0 XVMP050 XVMP080 XVMP042 XVMP04502 XVMP04802 XVMP02 XVMP0502 XVMP0802 acing-pdu Mounting Panel,.5"W, 42RU, Black acing-pdu Mounting Panel,.5"W, 45RU, Black acing-pdu Mounting Panel,.5"W, 48RU, Black acing-pdu Mounting Panel, 7"W, 42RU, Black acing-pdu Mounting Panel, 7"W, 45RU, Black acing-pdu Mounting Panel, 7"W, 48RU, Black acing-pdu Mounting Panel,.5"W, 42RU, White acing-pdu Mounting Panel,.5"W, 45RU, White acing-pdu Mounting Panel,.5"W, 48RU, White acing-pdu Mounting Panel, 7"W, 42RU, White acing-pdu Mounting Panel, 7"W, 45RU, White acing-pdu Mounting Panel, 7"W, 48RU, White 7" acing-pdu mounting panel.5" acing-pdu mounting panel Tool-ess PDU Mounting Panel (for XN Style Enclosures) PDU Mounting Bracket Double, Post Mounting 2 PDU Side-by-Side Facing Into Enclosure PDU Mounting Bracket Single, Rear Facing Pair PDU Mounting Bracket Rear Facing Pair Between Frames PDU Mounting Bracket Rear Facing Pair Between Frames with Extension Manager Panel, 42RU X 7.0"W, Black Manager Panel, 45RU X 7.0"W, Black Manager Panel, 48RU X 7.0"W, Black Manager Panel, 42RU X 7.0"W, CO White Manager Panel, 45RU X 7.0"W, CO White Manager Panel, 48RU X 7.0"W, CO White Tool-ess PDU Mounting Panel (for XSS Seismic Enclosures) XNPM0 XNPM02 XNPM0 XNPM04 XNVP4290 XNVP4590 XNVP4890 XNVP42902 XNVP45902 XNVP48902 Mounting Brackets Cable PDU Manager Rear Panel, 44RU, Rear, Black Cable PDU Manager Rear Panel, 44RU, Rear, with 6 Rings, Black Cable PDU Manager Rear Panel, 44RU, Rear, CO White Cable PDU Manager Rear Panel, 44RU, Rear, with 6 Rings, CO White Tool-ess PDU Mounting Panel (for XSN Seismic Enclosures) XSN44VRPM0 XSN44VRPM XSN44VRPM02 XSN44VRPM2 Cable PDU Manager Rear Panel, 44RU, Rear, Black Cable PDU Manager Rear Panel, 44RU, Rear, with 6 Rings, Black Cable PDU Manager Rear Panel, 44RU, Rear, CO White Cable PDU Manager Rear Panel, 44RU, Rear, with 6 Rings, CO White Power Cord Management XSN44VRPM0 XSN44VRPM XSN44VRPM02 XSN44VRPM2 Quick Mount Base XMR0 XMR0 XSK0 XCTM AX0078 AX00784 Cord Set* (C/C9, C9/C - U - cu isted) C to C4 n-ocking Cord Set - Y" ong Black C to C4 n-ocking - 6" ong Black C to C4 n-ocking - 48" ong Black C9 to C n-ocking Cord Set - Y" ong Black C9 to C n-ocking - 6" ong Black C9 to C n-ocking - 48" ong Black C ocking to C4 - " ong Blue C ocking to C4 - " ong Orange C9 ocking to C - " ong Blue C9 ocking to C - " ong Orange C ocking to C4-9" ong Blue C ocking to C4-9" ong Orange C9 ocking to C - 9" ong Blue C9 ocking to C - 9" ong Orange CSCC4yyBK CSCC46BK CSCC448BK CSC9CyyBK CSC9C6BK CSC9C48BK CSCC4B CSCC4OR CSC9CB CSC9COR CSCC49B CSCC49OR CSC9C9B CSC9C9OR ocking Cord Set* *Built within the plug housing on the female end (C/C9) of the cord, the patented integrated locking mechanism is protected against vibration and external elements that can easily dislodge other plug securing solutions, like external locking clips and guides. This self-contained locking mechanism engages with any standard IEC male connector (C4/C). The cord locking feature is only available at the device-end of the cord sets. A power strip with locking receptacles must be available to secure these cords to the PDU. tes: yy = 2,, = cord length 2 to 96 inches; 2 inch increments..800.beden. ( ) 77 Cable Management Ring Plastic (Qty = 5) " x.5" Reversible Cable Management Ring Kit (Qty = 5) 2.5"W x "D Slack Management Spool Kit (includes 2 spools) Quick Mount Base (Qty=0) with Fastener, for /4" Holes Velcro Cable Ties, 25 per Roll, 8" x 0.5"W Velcro Cable Ties, 25 per Roll, 2" x 0.5"W Cable Management Ring (Plastic)
6 Power Distribution Unit Configuration Guide Please select the desired configuration and specifications and submit to Belden. Power Availability Quantity Required First Unit Required by Date Electrical Configuration Power Input Quantity** Input S Input 5-5P P P 25 5-P 25 6-P 6-P 4-P 25/ 2-P x ~ /8 WYE 5-P 25 6-P 4-P 25/ 5-P x ~ Delta 2-P x ~ /8 WYE IEC C- Inlet ( Cord) /6* 25 or 2 Pole/ Wire /6* /2* Pole/4 Wire ~ 2 Pole/ Wire /2* /2* Pole/4 Wire ~ 2 Pole/ Wire /6* /2* Pole/4 Wire ~ Cord ength tes: *Rating for CE Products **Quantity = # of Circuits Phone Target Price Comparable Competitive Unit Brand/Model# Power Input Quantity S 5-5R Duplex R Individual R Duplex R Duplex 25 5-R Individual 25 5-R 25 6-R Duplex 6-R 5-R 25 6-R IEC C- 5/0* 25 or IEC C-9 /6* 25 or Other - Please Specify Physical Configuration Dimensional imits ength Width Height Hardwire Options Quantity** Additional Information Mounting Orientation 6" Wire Tails with Removable Plate Flexible Conduit Terminal Block Horizontal Project Timeline Power Switch Monitoring - with Cover Current ocal - Current (Amps) Only - Scrolling Display (Volts, Amps, Watts, Power Factor) Environmental Circuit Breakers (required by NEC in some units) rd Party Testing - Compliance U isted Surge Supression Current Remote - Circuit evel - evel Remote Switching Isolated Ground UR - U Recognized FCC Part 5 Class A CE ne Required Other - Please Specify BEDEN. ( )
7 and Configuration Chart NEMA s and s Straight-Blade P 5-5R 25 5-P 5-R P 5-5R /8 x ~ WYE 2-P 2-R 25 5-P 5-R 2/400 x ~ WYE 22-P 22-R 25 5-P 5-R /8 x ~ WYE 2-P 2-R 6-P 6-R 2/400 x ~ WYE 22-P 22-R 6-P 6-R x ~ Delta 5-P 5-R 25/ 4-P 4-R 25/ 4-P 4-R 50 x ~ Delta /6* 25 or Twist-ock Straight-Blade Twist-ock Straight-Blade Straight-Blade 6-P 6-R Twist-ock Twist-ock California Style IEC s and s Power Inlet Power 5/0* 25 or /6* /2* 2P, W 2P, W /6* /2* 2P, W 2P, W /2* /2 2P, W 2P, W /6* 2/400* x ~ WYE /2* 2/400* x ~ WYE C-4 C- Pin & Sleeve Power Inlet Power C- C-9 Pin & Sleeve *Rating for CE Products What is -Phase WYE? -Phase Delta from 8V Source -Phase Delta from /8V Source X Phase X Phase Ground Z Phase Y Phase 8V (XY) Z Phase Ground 2-P 8V (XY) Y Phase 8V (ZX) 8V (ZX) Y Phase V (XN) 8V (YZ) A -Phase Delta is a 4-wire configuration consisting of -Phase conductors (X, Y and Z) and a Ground. Without the neutral present, only phase-to-phase wiring is possible. The potential between any 2-Phase conductors is typically 8V. Phase WYE Phase Delta X Phase Neutral 5-P A -Phase Delta /8V WYE is a 5-wire configuration consisting of -Phase conductors (X, Y and Z), Neutral and Ground. The potential between any 2-Phase conductors is 8V. The potential between any phase and neutral is V. This configuration can be wired to provide V, 8V or a combination of both voltages within one PDU..800.BEDEN. ( ) What is -Phase Delta? 8V (YZ) Z Phase V (YN) V (ZN) Neutral Ground 79
Intelligent-Remote Monitoring (3) Environmental Port (4) Power Outlet Level (5)
Faster. Enclosure Power Distribution Units (PDUs) (continued) PDU Selection: Basic, with Local and Intelligent PDU mounted display option for local current or power monitoring, making phase balancing easier
More informationRack- and Panel-Mount Power Distribution Units (PDUs)
Spec-00193 Cable and Power Management Power Distribution Units (PDUs) Rack- and Panel-Mount Power Distribution Units (PDUs) FEATURES Power on/off LED indicates whether power is available at the PDU External
More informationPower Distribution. For technical support call Online catalog available at leviton.com 461
INDEX FLX Series... 463 Switched Series... 464 Metered Series... 465 P1000 Series... 466 5500 & 5505 Series... 467 4500 Series... 468 For technical support call 800-824-3005 Online catalog available at
More informationPolar PDUs POWER MANAGEMENT
Polar Power Distribution Units (PDUs) provide the ultimate solution for combining cabinet level power management, environmental monitoring, and cabinet access control in multi-tenant and enterprise data
More informationPower Monitoring (RCX)
Power Monitoring (RCX) Geist s Power Monitoring PDUs provide a comprehensive remote view of your installation s power utilization. In addition to Amps, Volts, Real Power, Apparent Power, Power Factor and
More informationPDU. InfraPower POWER AUSTI AUSTIN AUSTIN AUSTIN 3 PHASE WSI WI WS W MD BASIC. Enclosure Power Management Solutions
PDU A AUSTI POWER 3 PHASE WSI WI WS W MD BASIC Temperature & Humidity Sensors A pair of sensors can be connected to one single W series PDU meter. 3 PHASE Free Management Software Manager enhances the
More informationRack- and Panel-Mount Power Distribution Units (PDUs)
Spec-00193 Cable and Power Management Power Distribution Units (PDUs) Rack- and Panel-Mount Power Distribution Units (PDUs) FEATURES INDUSTRY STANDARDS UL/cUL 60950 listed UL 1449 (Surge protector models
More informationFrequently Asked Questions
Q. What is the power metering accuracy on CPI econnect PDUs? A. The power metering accuracy on CPI econnect PDUs is ±1% for each breaker. Meters are included in Monitored, Monitored, Switched and Switched
More informationPOWER DISTRIBUTION UNITS (PDUs)
P R O D U C T D ATA S H E E T POWER DISTRIBUTION UNITS (s) for CPI Rack and Cabinet Systems K E Y F E AT U R E S Distribute power to multiple devices from a single power connection NEMA, California Style
More informationInnovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s
Structure Source PDU s Innovative Power Engineering High Quality Power Distribution for the Data Centre structure source Making the complex, simple structure source product range Rack and Server Power
More informationPower Distribution Units for Data Centers
WWW.SIEMON.COM Power Distribution Units for Data Centers PowerMax Power Distribution Units Siemon s PowerMax line of PDUs range from basic and metered for simple, reliable and cost-effective power distribution,
More informationThe -3Ph extension on a product indicates a 3 Phase power product.
Power Terms Glossary 20-Amp Power Input Support: 20-amp Power Input Support. IEC320/C20 power inlet receptacles supports any power cord with IEC320/C19 power connector (PTCORD-XX). 24-Character Outlet
More informationCS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link)
CS-12HDE444C8 (Master) CL-12HDE444C8 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while
More informationSwitched, Outlet Level Monitoring
Part Number Power Configuration Physical Configuration RCURN082-102D20TL5-OD Switched, Outlet Level Monitoring 20A, 120V, 1.9kW 19in / 483mm Horizontal Description The RCURN082-102D20TL5-OD provides hands-on
More informationRCOBN PH6TL21-D Power Monitoring, Outlet Level. Part Number
Part Number Power Configuration Physical Configuration RCOBN248-102PH6TL21-D Power Monitoring, Outlet Level 20A, 120/208V WYE, 5.7kW 66 in Vertical Description RCOBN248-102PH6TL21-D provides site managers
More informationPDU - Overview / Non-Intelligent PDU s
PDU - Overview / Non-Intelligent PDU s InfraPower Rack Power Distribution Units InfraPower Rack PDU Range Switched (Outlet kwh PDU) Monitored (kwh PDU) Metered Basic WSi WS W MD Basic Outlet Measurement
More informationTripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.
POWER DISTRIBUTION UNITS Tripp Lite rack power distribution for high-density IT environments. Introduction 2-3 Basic 4 Metered 5 Monitored 6 Switched 7 ATS 8 Hot-Swap 8 INTRODUCTION Tripp Lite Rack increase
More informationPower Distribution Units for Data Centers
BRC_PowerMax_INT_Draft_I.qxp_Layout 1 9/11/17 2:00 PM Page 2 Power Distribution Units for Data Centers WWW.SIEMON.COM PowerMax Power Distribution Units 2 Siemon s PowerMax line of PDUs range from basic
More informationInspired by Your Data Center. Intelligent W Series : 3 - Phase 208V
Inspired by Your Data Center Intelligent W Series : 3 - Phase 208V Three Phase for Rising Power Usage High power density has been implemented in applications such as high-end network switches, storage
More informationG5 PDU Installation Guide
G5 PDU Installation Guide 1 Contents Before You Begin... 3 Overview... 3 Important Safety Information... 3 Required Tools... 5 Section 1 Introduction... 6 Classification Overview... 6 Features... 7 Form
More informationCS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link)
CS-10H0A413H3 (Master) CL-10H0A413H3 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while
More informationCS-24VD-L30MA (Master) Key Features. CL-24VD-L30MA (Link)
CS-24VD-L30MA (Master) CL-24VD-L30MA (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while
More informationMetered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord
Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord APC Metered Rack PDU, Input: 208V 3PH, Input Connections: NEMA L21-20P, Cord Length: 10 feet ( 3.05 meters ), Output: 208V,
More informationG GRCOW PH6PS6-D-IP44 Power Monitoring, Outlet Level. Part Number
Part Number Power Configuration Physical Configuration G1306 -- GRCOW246-103PH6PS6-D-IP44 Power Monitoring, Outlet Level 32A,, 7.3kW 72 in / 1829 mm Vertical Description G1306 -- GRCOW246-103PH6PS6-D-IP44
More information25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA
25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC 309 60A Red 415V, 0U, TAA MODEL NUMBER: PDU3XEVSR6G60B Highlights 25.2kW 240V 3-phase switched 1.8m
More informationMetered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord
Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord APC Metered Rack PDU, Input: 208V 3PH, Input Connections: Hubbell CS8365C, Cord Length: 10 feet ( 3.05 meters ), Output:
More informationHow do I... If you manage a datacenter, we have a solution for you. Sentry : Cabinet Power Distribution Unit Product Family : Metered CDU.
If you manage a datacenter, we have a solution for you. How do I... Distribute power to all the equipment in the cabinet? Distribute and load balance 3-phase power? Monitor True RMS input current? Reboot
More informationMetered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13
Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13 APC Metered Rack PDU, Input: 230V, Input Connections: IEC-320 C14, Cord Length: 10 feet ( 3.05 meters ), Output: 230V, Output Connections:
More informationPanduit Basic Rack PDU with Local Meter
Panduit Basic Rack PDU with Local Meter User Manual Release 1.0 Issue 1.0 Copyright 2014 Panduit Corp. All rights reserved. No part of this book shall be reproduced, stored in a retrieval system, or transmitted
More informationSECTION SWITCHBOARDS
SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS
More information5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA
Management Interface The management interface for this PDU model is transitioning to a new technology platform. The new interface can be distinguished by a USB-A port (for EnviroSense2 modules) in place
More informationCisco CRS 16-Slot Chassis Power Systems
This chapter includes the following sections: Power specifications are provided in Technical Specifications Power Systems Overview, on page 1 Power Component Information Common to the Two Types of Power
More informationSwitched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.
Switched XPDU 15A Model User & Installation Manual www.xpcc.com 2014. All rights reserved. (Rev 10/02/14) Table of Contents Introduction...4 PDU Package...4 Function...4 Interface...4 Installation...5
More informationipdu Pocket Guide NORTH AMERICA
Best in Class Outlet Density Optimal Form Factors Superior Reliability TM ipdu Pocket Guide NORTH AMERICA Welcome to the Panduit G5 Series of PDU s and Accessories Quality & Reliability 3-Year standard
More informationUser Manual. Per Port Monitoring Models
User Manual Per Port Monitoring Models Table of Contents 1. Introduction... 1 2. Package Contents... 2 3. Function... 3 4. Installation... 5 5. Web Interface... 6 1. Introduction The ServerLink Per Port
More informationAPC APPLICATION NOTE #74
#74 Configuration of InfraStruXure for Data Centers to Support Dell PowerEdge 1855 Abstract Many companies are making plans to incorporate Dell PowerEdge Blade Servers into their data center applications.
More informationCAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. Available in Basic, Metered, and Smart PDU models.
CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. You ve never seen anything like this before. TM Introducing the PDU Power Pivot, the newest patented innovation from Server Tech, inventors of
More informationQUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!
QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationBCM2 Series Branch Circuit Monitors Quick Setup Guide
BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationCisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2
Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,
More informationPDU Inspired by Your Data Center. W IEC PDU Series
PDU Inspired by Your Data Center W IEC PDU Series Intelligent kwh PDU - W series Power Efficiency Management With today s increasing demand for high technology power management solutions, PDU kwh measurement
More informationThe Basics of Selecting Rack-Mount Power Distribution Units (PDUs) and Power Strips
WHITE PAPER The Basics of Selecting Rack-Mount Power Distribution Units (PDUs) and Power Strips By David Knapp Product Marketing Manager Chatsworth Products (CPI) Published: January 2019 US & Canada +1-800-834-4969
More informationPDI Modular Compact Remote Power Panel
Guide Specifications (Revision 000, 6/17/2016) 1 GENERAL 1.1 Summary These specifications describe requirements for a remote power panel (RPP) distributing power to sensitive loads. These specifications
More informationECO PDU Power Distribution Unit
ECO PDU Distribution Unit PE6108/PE6208/PE8108/PE8208 ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage.
More informationMetered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R
Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R APC Metered Rack PDU, Input: 120V, Input Connections: NEMA L5-20P, Cord Length: 10 feet ( 3.05 meters ), Output: 120V, Output Connections:
More informationBasic PDU Modules SW Meter PDU SW Meter Switch PDU SW Three Phase PDU. How to install 11-12
01-02 Basic PDU 03-04 Modules 05-06 SW Meter PDU 07-08 SW Meter Switch PDU 09-10 SW Three Phase PDU 11-12 How to install Safewell Basic PDU Series Model:SW-1U-8IEC13-K Product Description Size 19 * 1U
More informationAcquiSuite Ally 48 Advanced Branch Circuit Monitor
AcquiSuite Ally 48 Advanced Branch Circuit Monitor AMC48-MD AMC48-ED Split Core CT Split Core CT Ally Rogowski Rope CT DESCRIPTION The AcquiSuite Ally 48 is the perfect companion to the data acquisition
More informationipdu Pocket Guide INTERNATIONAL
Best in Class Outlet Density Optimal Form Factors Superior Reliability TM ipdu Pocket Guide INTERNATIONAL Welcome to the Panduit G5 Series of PDU s and Accessories Quality & Reliability 3-Year standard
More informationANI SWH. PDU: Per Outlet Control and Total Current Monitoring INSTRUCTION MANUAL
ANI-15115-08SWH PDU: Per Outlet Control and Total Current Monitoring INSTRUCTION MANUAL 122 Rose Ln., Suite 303, Frisco, Texas 75034 TOLL FREE: 1-877-ANEUTRON TOLL: (469) 362-9228 Email: sales@a-neutronics.com
More informationSECTION ( ) LIGHTING CONTROL PANELBOARD
(26 24 16.02) LIGHTING CONTROL PANELBOARD PART 1 GENERAL 1.01 SCOPE A. The Contractor shall furnish and install Lighting Control Panelboards as specified and as shown on the contract drawings. B. The Lighting
More informationInstruction Manual Basic Rack PDU VP7541 and VP9571A
Instruction Manual Basic Rack PDU VP7541 and VP9571A VertivCo.com/geist Table of Contents Specifications... 3 Overview... 3 Environmental... 3 Temperature... 3 Humidity... 3 Elevation... 3 Electrical...
More informationBS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0
BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY
More informationQuickSpecs. HPE G2 Metered Power Distribution Units. Overview HPE G2 Metered Power Distribution Units
Overview Setting new standards for reliable power distribution and metering HPE Advanced Series G2 Metered PDUs are designed to work precisely with HPE Infrastructure and Compute solutions, providing a
More informationPanduit Basic Rack PDU
Panduit Basic Rack PDU User Manual Release 1.0 Issue 1.0 Copyright 2014 Panduit Corp. All rights reserved. No part of this book shall be reproduced, stored in a retrieval system, or transmitted by any
More informationQuickSpecs. HPE Metered and Switched Power Distribution Units (PDU) Overview
HPE Metered and Switched Power Distribution Units (PDU) Overview Looking for a power distribution unit that meets the demands of high temperature operating environments and provides monitoring and switching
More informationInspired by Your Data Center. Intelligent W Series : 3 - Phase 400V
Inspired by Your Data Center Intelligent W Series : 3 - Phase 400V Three Phase for Rising Power Usage High power density has been implemented in applications such as high-end network switches, storage
More informationIBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide
IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide The IBM 1U Switched and Monitored Power Distribution Units (PDUs) make it quick and simple to deploy, protect, and
More informationModels. Specifications
CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. You ve never seen anything like this before. Intro- TM ducing the PDU Power Pivot, the newest patented innovation from Server Tech, inventors
More informationSmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch
SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch MODEL NUMBER: SU8000RT4U Description Tripp Lite 8kVA SmartOnline
More informationLiebert MPX Rack Power Distribution Unit (PDU) Guide Specifications 1.0 GENERAL 1.1 SUMMARY
1.1 SUMMARY Liebert MPX Rack Power Distribution Unit (PDU) Guide Specifications 1.0 GENERAL This specification defines the electrical and mechanical characteristics and requirements for a continuous-duty,
More information30, 50, and 60 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units
30, 50, and 60 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to enable intelligent
More informationInstruction Manual. Rack PDU XP Series. geistglobal.com
Instruction Manual Rack PDU XP Series geistglobal.com Table Of Contents 3 Table of Contents Specifications 4 Overview... 4 Environmental... 4 Tem perature... 4 Hum idity... 4 Elevation... 4 Electrical...
More informationConfigurable power distribution
Configurable power distribution 60 150 kva The easy-to-deploy for data centers with custom requirements Configured to order, factoryassembled power distribution for IT equipment in any size data center
More informationIntelligent W Series : 3 - Phase 208V 20A / 30A. Inspired by Your Data Center
Intelligent W Series : 3 - Phase 208V 20A / 30A Inspired by Your Data Center Three Phase for Rising Power Usage High power density has been implemented in applications such as high-end network switches,
More informationIntelligent PDUs. Best in Class Outlet Density Optimal Form Factors Superior Reliability
TM Intelligent PDUs Best in Class Outlet Density Optimal Form Factors Superior Reliability SmartZone G5 Value Proposition Quality & Reliability High Temp High Power Density Hot-Swappable and Upgradable
More informationTripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.
POWER DISTRIBUTION UNITS Tripp Lite rack power distribution for high-density IT environments. Introduction 2-3 Basic 4 Metered 5 Monitored 6 Switched 7 ATS 8 Hot-Swap 8 INTRODUCTION Tripp Lite Rack increase
More informationPOWER CABLES FOR MISSION CRITICAL FACILITIES
POWER CABLES FOR MISSION CRITICAL FACILITIES UL LISTED, MISSION-CRITICAL POWER CABLES MANUFACTURED AND TESTED IN A CONTROLLED ENVIRONMENT With 24-Hour Turn-Around, an unprecedented number of receptacles,
More informationInspired by Your Data Center. 1-Phase Intelligent PDU IEC Outlet 208V / 230V
Inspired by Your Data Center 1-Phase Intelligent PDU IEC Outlet / 230 Intelligent kwh PDU - W series Power Efficiency Management With today s increasing demand for high technology power management solutions,
More informationpower.apitech.com Standard Solutions
power.apitech.com Standard Solutions Standard Commercial Solutions Section 3 Section 2 Section 1 Satellite Strips, Basic Power Strips AC and DC SMARTStart Power Strip Accessories Power Distribution Considerations
More informationThe power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.
The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings
More informationManaged Rack PDU MPH2 More efficient Simpler Better
Managed Rack PDU MPH2 More efficient Simpler Better MPH2 Managed Rack PDU The newly developed Managed Rack PDU MPH2 TM is a power supply system with monitoring and control functions. Standout features
More informationSmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules
SmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules MODEL NUMBER: SV40KM2P2B Highlights Scalable capacity up to
More informationSetting new standards for reliable power distribution and metering
Overview Setting new standards for reliable power distribution and metering HPE G2 Switched PDUs are designed to work precisely with HPE Infrastructure and Compute solutions, providing a highly accurate
More informationPrisma II Platform. Optoelectronics
Optoelectronics Prisma II Platform Description In optical transmission systems, the network platform forms the foundation of the product family. The Prisma II platform provides network operators with the
More informationInspired by Your Data Center. 1-Phase Intelligent PDU Outlets for 230V
Inspired by Your Data Center 1-Phase Intelligent PDU Outlets for 30V Intelligent kwh PDU - W series Power Efficiency Management With today s increasing demand for high technology power management solutions,
More informationZonit μats TM Users Guide μats1-lv Version 1.2
Zonit μats TM Users Guide μats1-lv Version 1.2 Table of Contents Product Overview...2 Pre-Installation Considerations...2 Product Features...3 Installation...4 Optional Accessories...4 μats TM Operational
More informationTable of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4
User Manual Table of Contents 1. Introduction... 1 2. Package Contents... 2 3. Function... 3 4. Installation... 2 5. Web Interface... 4 1. Introduction The ServerLink PDU is a network ready device designed
More informationAPC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications
APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications The Cisco Unified Computing System is a next-generation data center platform that unites compute, network,
More information16 and 32 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units
16 and 32 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to enable intelligent
More information20 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units
20 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to enable intelligent management
More informationECO PDU PE7108/PE7208
PE7108/PE7208 ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage. The PE7108 / PE7208 eco PDUs are intelligent
More informationSmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module
SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module MODEL NUMBER: SV20KS1P0B Highlights Scalable capacity up
More informationQUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!
QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationGFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding
GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding AU1-10R AU1-10P FR1-R EU1-P Cat. No. Drawing Configuration Australian GFCI (RCD) angle plug. trip. 10 ampere 230 volt, 50 Hz. 20 watt maximum. Test
More information16 and 32 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units
16 and 32 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units SPECIFICATION SHEET specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to
More informationInspired by Your Data Center. 1-Phase Intelligent PDU US NEMA Outlet 110V
Inspired by Your Data Center 1-Phase Intelligent PDU US Outlet 110V Intelligent kwh PDU - W series Power Efficiency Management With today s increasing demand for high technology power management solutions,
More informationCisco Prisma II Platform
Cisco Prisma II Platform In optical transmission systems, the network platform forms the foundation of the product family. The Cisco Prisma II platform provides network operators with the unique features
More information550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure
550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure MODEL NUMBER: AV550SC Highlights 4 AC outlets (including 1 delayon outlet for router) Automatic recycle/reset
More informationPDU Solutions. PDU Solutions
Canovate offers a full range of PDU s from basic and metered ones to IP PDU s with per socket switching capability and wireless sensor connectivity. Our PDU s can be used in the most complex ISP and Colocation
More informationECO PDU PE5108/PE5208
1 NRGence Energy Intelligence Solutions PE5108/PE5208 ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage.
More informationSmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System
SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System MODEL NUMBER: SVX120KL Highlights 120kVA / 120kW modular, scalable, 3-phase, Large-Frame tower
More informationExcel Power Distribution
www.excel-networking.com Excel Power Distribution Section 7 In this Section: Pages Power Distribution Units 154 Efficiency Measurements 154 Excel Modular PDU Range 155 Excel Standard PDUs 156 Excel Intelligent
More informationQuickSpecs. HPE Standard Series G2 Basic Power Distribution Units (PDU) Overview. Basic, reliable power distribution for your HPE IT solutions
Overview Basic, reliable power distribution for your HPE IT solutions G2 Basic PDUs are designed to work precisely with HPE Infrastructure and Compute solutions and guarantee a compatible fit for use with
More informationSmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial
SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU16000RT4U Description Tripp Lite 16kVA SmartOnline
More informationAll power outlet units include 10' power cords, mounting brackets, screws, unit packaging:
30, 50, and 60 Amp PanView iq TM (PViQ TM ) Switched with Per Outlet Monitoring specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to enable intelligent management
More informationSpecification Sheet: HT SERIES
Specification Sheet: HT SERIES HT Series: High Specification 19 Enclosures Hi-tech Series of 19 enclosures, supplied in self assembly (flat pack) format for ease of transportation and storage. Manufactured
More informationC2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) Key Features
C2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) The Server Technology PRO2 Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine
More informationBS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL
BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax: +31
More informationDeploying High Power to IT Equipment Racks
1 Deploying High Power to IT Equipment Racks A White Paper from Raritan 2 Table of Contents Overview...3 Trends in Data Center Power Deployment...3 Drivers for High Power Racks...4 Data Center Power Distribution
More information30 Amp PanView iq TM (PViQ TM ) Switched with Per Outlet Monitoring and Environmental Power Outlet Units. specifications. technical information
SPECIFICATION SHEET specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to enable intelligent management of the in-cabinet power usage. This system helps to quickly