1 S&C IntelliRupter PulseCloser Fault Interrupter Outdoor Distribution, 15.5 kv through 38 kv

2 IntelliRupter PulseCloser Fault Interrupter Tomorrow s Technology Available Today S&C s IntelliRupter PulseCloser Fault Interrupter is a breakthrough in overhead and underground distribution system protection. This unitized package of fault-interrupting and control components can operate as a stand-alone fault interrupter or, with appropriate options, can be integrated into a SCADA system and/or an S&C IntelliTeam SG Automatic Restoration System. IntelliRupter fault-interrupting devices feature S&C s revolutionary PulseClosing Technology a unique means for verifying that the line is clear of faults before initiating a close operation. PulseClosing Technology is superior to conventional reclosing. It greatly reduces stress on system components, as well as voltage sags experienced by customers upstream of the fault. Overhead System Applications IntelliRupter fault interrupters provide outstanding protection on overhead systems through 38 kv. They are available in upright-crossarm and compact-crossarm mounting configuration models, with or without an integrated, hookstick-operated disconnect for visible air-gap isolation of switched-open circuits. See Figure 1. IntelliRupter fault interrupters provide full liveswitching performance under all ice conditions circuit making, circuit breaking, and advanced fault interrupting are accomplished within the interrupters. There are no external moving parts. On disconnect-equipped models, the disconnect is interlocked with the interrupters to ensure they are open prior to opening or closing the disconnect. The interrupting devices may be operated with the disconnect in either position. A status point is provided for remote monitoring of disconnect position. IntelliRupter fault interrupters are factoryassembled on a stainless-steel base and include: Three-pole vacuum interrupters rated 630 amperes continuous, 16,000 amperes interrupting at 15 kv, and 12,500 amperes interrupting at 27 kv and 38 kv. A continuous current rating of 800 amperes applies with a 2 ft./sec. wind, similar to conductor ratings. Unique magnetic latching actuators for the interrupters, providing single-phase tripping/ single-phase lockout, single-phase tripping/ three-phase lockout, or three-phase tripping/ three-phase lockout. Interrupters can be manually tripped by means of a manual lever, operable from the ground with an extendostick. High-accuracy sensors, for three-phase monitoring of line current and three-phase monitoring of line voltage on both sides of the interrupters. Sensing accuracy is ±0.5% for both voltage and current. Total system accuracy for fault detection, including sensing, control, and interrupting time is ±2%. One or two integral power modules, which derive energy directly from the distribution line. Control power can alternately be derived from an external power supply. Open/close indicator for each phase. External power supply connector. Permits pre-installation uploading and downloading of configuration settings, plus radio programming and battery charging, as applicable, indoors in your service center or lab. Manually actuated OPEN/CLOSE/READY lever, operable from the ground with an extendostick. Manually actuated ground trip blocking lever, operable from the ground with an extendostick. Manually actuated hot-line tag lever to enable or disable a hot line tag or disable an electronically set hot line tag, operable from the ground with an extendostick. Control group, featuring a hookstick-removable protection and control module and communication module, mounted in the base. It s easily configured from the safety and security of your vehicle parked near the base of the pole, using a secure Wi-Fi communication link to a laptop computer. Unique multi-function status indicator. Shows that the control group is operating normally. Blink rate changes when Wi-Fi connection is made, control power is lost, or position of OPEN/CLOSE/ READY lever is changed. Separate hot line tag indicator shows a set tag. Integrated Global Positioning System. Provides 1-ms accurate time-stamping of events to speed post-event analysis, as well as IntelliRupter fault interrupter location data for entry into your graphical information system. Provisions for three surge arresters on each side of IntelliRupter fault interrupters. Factory-installed and wired MacLean Power Systems Zforce Type ZHP (Heavy Duty) polymer-housed metal-oxide surge arresters are optionally available. Single-point lifting means, for convenient rigging and hoisting during installation. 2

3 Figure 1. Top: A Disconnect-Style IntelliRupter PulseCloser Fault Interrupter in the uprightcrossarm mounting configuration. Bottom: Non-Disconnect Style IntelliRupter PulseCloser Fault Interrupter in the upright-crossarm mounting configuration. 3

4 Underground System Applications Pad-Mounted Style IntelliRupter fault interrupters provide full live-switching performance on underground systems through 27 kv. Circuit making, circuit breaking, and use of a pulse of current to detect the presence of a fault are accomplished within the interrupters. The factory-assembled, freestanding, self-supporting enclosure meets the requirements of ANSI C for enclosure integrity and includes provisions for cable entrance and exit through the bottom. See Figure 2. Pad-Mounted Style IntelliRupter fault interrupters are available with or without an integrated disconnect for visible air-gap isolation of switched-open circuits. The interrupters may be operated with the disconnect in either position. A status point is provided for remote monitoring of disconnect position. Pad-Mounted Style IntelliRupter fault interrupters feature: Three-pole vacuum interrupters rated 630 A continuous, 16,000 A interrupting at 15 kv, and 12,500 A interrupting at 27 kv. Unique magnetic latching actuators for the interrupters, providing single-phase tripping/singlephase lockout, single-phase tripping/three-phase lockout, or three-phase tripping/three-phase lockout. Interrupters can be manually tripped by means of a manual OPEN/CLOSE/READY lever. High-accuracy sensors, for three-phase monitoring of line current and three-phase monitoring of line voltage on both sides of the interrupters. Sensing accuracy is ±0.5% for both voltage and current. Total system accuracy for fault detection, including sensing, control, and interrupting time is ±2%. Choice of an integral power module, which derives energy directly from the distribution feeder, or an external power supply for use with user-furnished control power. Open/close indicator for each phase. External power supply connector. Permits pre-installation uploading and downloading of configuration settings, plus radio programming and battery charging, as applicable, indoors in your service center or lab. Manually actuated OPEN/CLOSE/READY lever. Manually actuated GROUND TRIP BLOCK toggle switch. Manually actuated HOT-LINE TAG toggle switch to enable or disable a hot line tag or disable an electronically set hot line tag. Control group, featuring a protection and control module and communication module, mounted in the low-voltage compartment. It s easily configured from the safety and security of your vehicle parked near the Pad-Mounted Style IntelliRupter fault interrupter, using a secure Wi-Fi communication link to a laptop computer. The modules can be easily removed using the module stub handle furnished. Unique multi-function status indicator. Shows that the control group is operating normally. Blink rate changes when Wi-Fi connection is made, control power is lost, or the position of the OPEN/CLOSE/ READY lever is changed. A separate HOT LINE TAG indicator shows a set tag. 4

5 Integrated Global Positioning System. Provides 1-ms accurate time-stamping of events to speed post-event analysis, as well as Pad-Mounted Style IntelliRupter fault interrupter location data for entry into your graphical information system. Controlled access to enclosure compartments. S&C s Penta-Latch Mechanism provides automatic door latching and permits padlocking only when the door is securely latched. Doors can only be opened with a pentahead socket wrench or tool. Long-lasting enclosure protection. The enclosure is protected from corrosion by S&C s Ultradur Finishing System. The roof is undercoated with an insulating no-drip compound. A resilient closed-cell gasket on the enclosure bottom flange protects the finish from being scratched during installation, and isolates it from the alkalinity of a concrete foundation. Terminals equipped with 600-ampere bushings (with studs). Bushing interfaces are in accordance with ANSI/IEEE Standard 386 and accept all standard separable insulated connectors. Parking stands are provided adjacent to each bushing. Grounding provisions, suitable for use with separable insulated connectors and related accessories, are located in the termination compartment. Hinged roof section over the cable-termination compartment, allowing easy cable pulling during installation. The cable-termination compartment accommodates either single 600-ampere deadbreak connectors equipped with elbow-style surge arresters, or two stacked 600-ampere deadbreak connectors without elbow-style surge arresters. Elbow-style surge arresters are required on both sides of Pad-Mounted Style IntelliRupter fault interrupters when installed on a feeder to protect it from surges beyond its ratings. When installed in a substation or at the base of a riser/dip pole, surge arresters are only required on the load side of Pad-Mounted Style IntelliRupter fault interrupters. Figure 2. A Pad-Mounted Style IntelliRupter PulseCloser Fault Interrupter. 5

6 Fault Testing with a PULSE... Instead of a BANG! Conventional reclosers stress the circuit with fault current every time they reclose into a fault. But after IntelliRupter fault interrupter interrupts a fault, it uses PulseClosing Technology to intelligently test for fault current before closing. The oscillograms in Figure 3 show the remarkable difference in current versus time during fault testing with a conventional recloser and an IntelliRupter fault interrupter. The relative let-through energy, in I 2 t, of an operation using PulseClosing Technology is typically less than 5% of a conventional reclosing operation, as shown in Figure 4. Current versus time conventional recloser fault from phase wire to grounded neutral Current versus time lntellirupter PulseCloser Fault Interrupter fault from phase wire to grounded neutral Figure 3. PulseClosing Technology drastically reduces overcurrent stress on the system, as shown here for a permanent phase-wire to grounded-neutral fault. 5,000,000 Conventional Reclosing 4,000,000 Ampere 2 Seconds 3,000,000 2,000,000 For more information on PulseClosing Technology, see Applications Assessment Of PulseClosing Technology on S&C s website, at: sandc.com/applicationassessment 1,000,000 Pulseclosing 0 0 2,000 4,000 6,000 8,000 10,000 Current, Amperes Figure 4. Relative let-through energy for a typical 5-kA fault. 6

7 Innovative Technology Is the Key After clearing a fault, a conventional recloser simply recloses the interrupters to test for continued presence of the fault. If the fault is still there, the interrupters are tripped again. Then, after a time delay, the interrupters are reclosed. With each reclosing operation, even the fastest recloser feeds a significant amount of energy into the fault, resulting in system-damaging stress and voltage sags. Figure 5 shows how a conventional recloser operates in response to a permanent single-phase-toground fault. The uncontrolled closing often results in asymmetric fault current, significantly increasing peak energy into the fault. But after an IntelliRupter fault interrupter clears a fault, it tests for continued presence of the fault using S&C s advanced magnetic actuator design, coupled with unique PulseClosing Technology. IntelliRupter fault interrupters intelligently close at a precise point on the voltage wave, resulting in a short pulse that s less than half the symmetrical fault current. Figure 6 shows how IntelliRupter fault interrupters operate in response to a permanent single-phaseto-ground fault, with a typical current pulse of just 5 milliseconds. With IntelliRupter fault interrupters, your system only experiences overcurrent stress from the initial fault not from every reclosing operation. Component life is extended, eliminating costly replacement. PulseClosing Technology also dramatically reduces through-faults a leading cause of premature aging of substation transformers. And power quality is improved since use of PulseClosing Technology doesn t disturb source-side customers with irritating voltage sags and blinks. Fully Compatible with IntelliTeam SG Automatic Restoration System IntelliRupter fault interrupters can take full advantage of S&C s IntelliTeam SG Automatic Restoration System. IntelliTeam SG is the latest generation of S&C s field-proven automatic restoration system. Its Rapid Self-Healing feature accomplishes restoration in seconds. The IntelliTeam SG system includes a setup tool IntelliTeam Designer which greatly simplifies configuration and deployment. The IntelliTeam SG system uses all available alternate sources to restore unfaulted line segments, without overloading any part of the system. The system minimizes the number of customers experiencing an extended power interruption, tremendously improving your system. Average Interruption Duration Index. IntelliTeam SG can handle multiple contingencies, too. Initial trip First PulseClose operation Initial trip First reclose operation Second reclose operation Figure 5. Conventional reclosing in response to a permanent fault. Second PulseClose operation Figure 6. Response to a permanent fault with PulseClosing Technology. The opposite-polarity pulse detects magnetizing inrush current; if the transformer is not faulted, IntelliRupter fault interrupter closes. For more information on the IntelliTeam SG Automatic Restoration System, see S&C Descriptive Bulletin on S&C s website, at: sandc.com/

8 Enhanced Performance in Loop Restoration Applications IntelliRupter fault interrupters enhance the performance of existing loop-restoration schemes using conventional reclosers. They eliminate the need to subject the alternate circuit in the loop to a fault when closing the tie. Just replace the recloser in the tie position with an IntelliRupter fault interrupter to take advantage of PulseClosing Technology. Even greater benefits can be achieved in loop schemes where all protective points use IntelliRupter fault interrupters. The device s fast interrupters and accurate sensing and control enable significant reductions in protection margins. With the negligible effect PulseClosing Technology has on source-side customers, the system can be segmented as needed without sacrificing protection. And with IntelliRupter fault interrupters protecting the loop, customers won t experience voltage sags on their good circuit during testing of a faulted circuit! Complaints and costly claims will be greatly reduced. Improved Reliability IntelliRupter fault interrupters improve reliability on both loop and radial circuits by overcoming the limits of conventional coordination methods. Seriesconnected IntelliRupter fault-interrupting devices can be configured so that after one device opens to isolate a fault, those downstream with the same settings also open. When power returns, the IntelliRupter fault interrupters use the PulseFinding Fault Location Technique to restore service. This technique automatically recovers from situations where an upstream device overreaches or otherwise miscoordinates with a downstream device. Here s an example: The feeder in Figure 7 includes a recloser, A1, and an IntelliRupter fault interrupter, A2. Due to tight or improper coordination, both devices trip in response to a fault downstream of the IntelliRupter Fault Interrupter. Figure 7. PulseFinding Fault Location Technique with an upstream recloser. When the recloser closes, in the next step of its operating sequence, it won t see the fault. So it remains closed. IntelliRupter fault interrupters, upon sensing return of voltage, use a pulse of current to detect the presence of a fault. The pulses are too short to initiate time-overcurrent timing of the recloser, so the recloser won t trip. If the fault is no longer present during the pulsing sequence, the IntelliRupter fault interrupter closes. The system is fully restored. If, however, the fault persists, the IntelliRupter fault interrupter locks out. But service is restored to customers served from the feeder section between the recloser and IntelliRupter fault interrupter. Those customers only experience a momentary outage from tripping of the recloser. If A2 were a recloser instead of an IntelliRupter fault interrupter, the system wouldn t be able to recover from the miscoordination between A1 and A2 because each reclose operation puts full fault current on the system. Both devices would again time and trip. Ultimately, A1 would lock out. With the IntelliRupter fault interrupter, more series-connected protective devices can be applied for better sectionalization. Each uses a pulse, in turn, to verify that its line segment is unfaulted, and then closes to restore service. Only the IntelliRupter fault interrupter closest to the fault locks out. IntelliRupter fault interrupters never close into a fault. Cold-load inrush is mitigated because only one line segment is energized with each closing. IntelliRupter fault interrupters don t need to communicate with each other to take advantage of this enhanced coordination and inrush mitigation. For more information on the enhanced performance and improved reliability provided by IntelliRupter fault interrupter, see Advancing the State of Looped Distribution Feeders on S&C s website, at: sandc.com/766-t83 A New Concept in Controls IntelliRupter fault interrupters are available with several kinds of control groups. Each offers easy configuration and operation and examination of waveforms and events using secure wireless communication to a nearby laptop computer. The control group includes a protection and control module and a communication module. See Figure 8. This flexible, low-maintenance arrangement offers excellent immunity to surges and noise induced by normal power-line events, such as faults and lightning strikes, and in the case of IntelliRupter fault interrupters for overhead system applications minimizes pole clutter. IntelliRupter fault interrupters are powered from the distribution line through the integral power module(s) or the external power supply, if furnished. The protection and control module provides pointon-wave closing to minimize asymmetric fault current and inrush current. It features a complete set of protection and control functions, including: Simultaneous independent directional phase ground, negative-sequence, and sensitive-earth 8

9 time-overcurrent, instantaneous-overcurrent, and definite-time elements Directional blocking of overcurrent elements Over/under voltage elements Over/under frequency elements Phase unbalance detection Synchronization check Cold-load pickup modifier Comprehensive diagnostics are included, too. A 20-channel GPS chip set provides 1-ms accurate time-stamping of events to speed post-event analysis, as well as IntelliRupter fault interrupter location data for your graphical information system. Select the control group that meets your needs: Standard Control Group. This control group is ideal for: IntelliTeam SG Automatic Restoration System applications. Teams use peer-to-peer communication, real-time data, and distributed intelligence to make automatic operating decisions. No central processing or SCADA is required, though fully supported. Each IntelliRupter fault interrupter must be furnished with an S&C SpeedNet Radio or other approved communication device. Automatic source-transfer applications using two IntelliRupter fault interrupters. The IntelliRupter fault interrupters ensure a high degree of critical-load continuity by minimizing interruptions resulting from loss of a source. For high-speed automatic source transfer, each IntelliRupter fault interrupter must be furnished with an S&C SpeedNet Radio or other approved communication device. Non-communicating IntelliRupter fault interrupters can also perform automatic source transfer using PulseClosing Technology. Automatic loop-restoration applications using normally closed IntelliRupter fault interrupters or conventional reclosers, with a normally open IntelliRupter fault interrupter switching point. The feeder on either side of the switching point can be fed from a different source. If a fault occurs on either feeder, the normally closed devices in that feeder open, then test the circuit using PulseClosing Technology (or reclosing) sequentially to sectionalize and isolate the fault. Service is automatically restored to unfaulted line segments by closing the normally open IntelliRupter fault interrupter. Intelligent fuse-saving applications. The IntelliRupter fault interrupter improves upon conventional fuse saving techniques. Based on fault current magnitude, an IntelliRupter fault interrupter automatically determines whether a fuse-saving fast trip should be used. At high fault currents, a fast trip isn t used, thus reducing momentary disturbances on the feeder. Wide-area SCADA applications. Each IntelliRupter fault interrupter must be furnished with an S&C SpeedNet Radio or other approved communication device. Stand-alone (non-communicating) applications. Communication Module Status Indicator (white LED) Flashes for ½ second every 30 seconds: Normal operation Pulsates dim to bright: Wi-Fi connected On 10 seconds, then flashes for ½ second every 30 seconds: Wi-Fi disconnected. Or Open/Close command from interrupter OPEN/ CLOSE READY lever, Wi-Fi, or SCADA On ½ second every second: Settings mismatch or error condition Off: IntelliRupter fault interrupter not powered or not functioning properly HOT-LINE TAG Indicator (amber LED) Flashes for ½ second every 2 seconds: Hot line tag applied Off: All hot line tags removed Protection and Control Module Figure 8. Control group includes protection and control module and communication module. 9

10 Approved communication devices permit configuration, operation, interrogation, and software maintenance of IntelliRupter fault interrupter from any location having access to the communication system, using IntelliLink Remote Setup Software. No batteries are required for stand-alone applications and applications with operating times of 30 seconds or less; ac line voltage must be available on the IntelliRupter fault interrupter side with the integral power module, or control power must be available from the external power supply, if furnished. The standard control group includes IntelliTeam SG Bronze-level software allows multiple IntelliRupter fault interrupters to be used in two source-restoration systems. When furnished with optional IntelliTeam SG Gold-level software, the standard control group software allows multiple IntelliRupter fault interrupters to be used in applications with three or more sources. IntelliTeam Designer configuration and license-management software unlocks IntelliTeam SG software, making setup fast and easy. Standard Control Group with Battery Backup. This control group is suitable for the same applications as the standard control group. It additionally includes batteries which support operation for a minimum of four hours after loss of ac line voltage on both sides of IntelliRupter fault interrupter, permitting extended dead-line switching. Universal Control Group. This control group is suitable for the same applications as the standard control group with battery backup. It additionally includes either IntelliTeam SG Gold-level software and IntelliTeam Designer configuration and license-management software or an IntelliTeam II Automatic Restoration System software license. When the former is specified, the universal control group may be used in IntelliTeam SG applications with three or more sources. When the latter is specified, the universal control group is suitable for IntelliTeam II applications. Easy Up Easy On IntelliRupter fault interrupter is totally self-contained an especially important consideration in overhead system applications. All major components including sensors, control group, surge arresters, control power, and disconnect (on disconnect style models) are included on the IntelliRupter fault interrupter base and go up in one easy, single-point lift. See Figure 9. Figure 9. Typical Disconnect Style IntelliRupter fault interrupter installation. Includes optional wildlifeprotection feature. Just mount an IntelliRupter fault interrupter on the utility pole and make a single ground connection to the base. Then screw the antenna for the wide-area network radio onto a connector on the base. Connect the high-voltage lines, and you re done! The IntelliRupter fault interrupter features embedded current and voltage sensors that eliminate the cost, clutter, and complexity of separately mounted sensors. There s no control enclosure or control cable to install, either. Because the IntelliRupter fault interrupter is directly powered from the line, there s no external potential transformer to install, no grounding issues to worry about. IntelliRupter fault interrupter installation typically takes about two hours or as little as one hour after your crews get experienced. 10

11 Compare the clean-looking IntelliRupter fault interrupter installation with that of a conventional recloser. See Figure 10. The photos really tell the story. Figure 11. An IntelliRupter fault interrupter has no external control or sensor cables. Figure 10. A typical conventional recloser installation. Control cables are vulnerable to damage from ice, rodents, and vandals. And sensor cables increase exposure to damage from lightning and power surges, and complicate grounding. IntelliRupter fault interrupter eliminates these potential problems. It doesn t have any external control or sensor cables! Compare the cable-less IntelliRupter fault interrupter in Figure 11 with the many-cabled conventional recloser in Figure 12. Figure 12. A conventional recloser has many external control and sensor cables. 11

12 Easy Operation The control group is easy to configure before installation. And it s just as easy to configure after installation, from the security of your vehicle parked up to 150 feet away, as shown in Figure 13. Just establish the secure Wi-Fi connection using your laptop computer and you re ready to go. The Wi-Fi transceiver in the communication module provides encrypted wireless point-to-point communication to your PC operating under the IEEE b standard. Extensive security features prevent unauthorized access. You can open and close lntellirupter fault interrupter, set hot-line tags, and change protection profiles using the simple operation screens. See Figure 14. Detailed logs, oscillography data, and other operational information can be readily accessed and transferred over the wireless link. Software upgrades too. And if an S&C SpeedNet Radio or other approved wide-area network radio has been furnished and it supports configuration through its serial port it can be configured through the wireless link as well. When IntelliRupter fault interrupter is set for remote operation, your dispatcher can test its electrical operation, as well as the entire SCADA control path, including communication. Figure 14. IntelliRupter fault interrupter operation screen. Figure 13. IntelliRupter fault interrupter control group is configured and operated using a secure Wi-Fi communication link. 12

13 If a PC isn t available, an IntelliRupter fault interrupter can be opened and closed and hot-line tags set using a hookstick from the ground or a bucket truck, as shown in Figure 15. Should module replacement ever be necessary, it s easily performed as well, as shown in Figure 16. There s no need to reconfigure an IntelliRupter fault interrupter a memory module in the base remembers all the settings. Figure 15. An IntelliRupter fault interrupter can be opened and closed and hot-line tags set using a hookstick. Figure 16. A protection and control module and communication module are easy to change out, if replacement is ever necessary. 13

14 Construction of IntelliRupter Fault Interrupters for Overhead System Applications A B C D E G F H I J K L Figure 17. A Disconnect-Style IntelliRupter fault interrupter in upright-crossarm mounting configuration, rated 15.5 kv maximum. A B C D E 60-Hertz Ratings 14 Integrated voltage sensors on both sides of lntellirupter fault interrupter provide highly accurate sensing across entire temperature range. Integrated current sensors provide extremely flat response, from low-level load currents through fault current levels, ensuring reliable measurements critical for system analysis. Sensors are molded into interrupter housings for all-weather durability. Integrated pole-mounting bracket is designed for easy installation; prevents tilting. Integral power module is fed from one side of an lntellirupter fault interrupter or, optionally, two integral power modules are fed from a different phase on both sides to maximize availability of control power. This eliminates cost and complexity of separately mounted control power transformers. Integrated disconnect provides visible air gap isolation for dead-line work and facilitates operational testing. Mechanically interlocked with interrupters. Optional factory-installed and wired surge arresters on both sides of an lntellirupter fault interrupter. Simplifies installation. See Figure 26. F HOT-LINE TAG lever. See Figure 23. G GROUND-TRIP BLOCK lever. See Figure 24. H Disconnect OPEN/CLOSE lever. See Figure 22. I Interrupter OPEN/CLOSE/READY lever. See Figure 20. J Control group features hookstick-removable protection and control module and communication module. Multi-function status light indicates control group is operating normally. Hot-line tag light indicates set tag. See Figure 8. K Stainless steel base provides outstanding corrosion-resistance, even in the harshest environments. L Interrupter OPEN/CLOSED indicator. See Figure 21. kv Amperes, RMS Minimum Maximum BIL Continuous Interrupting, Symmetrical amperes with a minimum wind velocity of 2 ft/sec.

15 A C B E F G I K L Figure 18. A Non-Disconnect Style IntelliRupter fault interrupter in upright-crossarm mounting configuration, rated 38 kv maximum. J A B C E Integrated voltage sensors on both sides of an IntelliRupter fault interrupter provide highly accurate sensing across the entire temperature range. Integrated current sensors provide extremely flat response, from low-level load currents through fault current levels, ensuring reliable measurements critical for system analysis. Sensors are molded into interrupter housings for all-weather durability. Integrated pole mounting bracket is designed for easy installation; prevents tilting. Integral power module is fed from one side of an lntellirupter fault interrupter or, optionally, two integral power modules are fed from a different phase on both sides to maximize availability of control power. Eliminates cost and complexity of separately mounted control power transformers. Optional factory-installed and wired surge arresters on both sides of an lntellirupter fault interrupter. Simplifies installation. See Figure 26. F HOT-LINE TAG lever. See Figure 23. G GROUND-TRIP BLOCK lever. See Figure 24. I Interrupter OPEN/CLOSE/READY lever. See Figure 20. J Control group features hookstick-removable protection and control module and communication module. Multi-function status light indicates control group is operating normally. Hot-line tag light indicates set tag. See Figure 8. K Stainless-steel base provides outstanding corrosion-resistance, even in the harshest environments. L lnterrupter OPEN/CLOSED indicator. See Figure

16 A B E D C Figure 19. A Non-Disconnect Style lntellirupter fault interrupter in compact-crossarm mounting configuration, rated 27 kv maximum. Furnished with features suitable for substation application. A Wildlife protection. See Figure 25. B Control group is furnished with factory-installed and wired fiber-optic modem. C Mounting pedestal is available in 9.5 and 12-foot versions. D E External power supply interface box (furnished with external power supply) provides plenty of room for fiber-optic connections. External power supply permits IntelliRupter fault interrupter to be powered from a pole-top transformer or substation battery. 16

17 Interrupter fault interrupter OPEN/CLOSE/READY lever for manually opening and closing interrupters. Pull the OPEN lever down to open the interrupters. The Open position can be tagged if desired. Interrupters can be tripped during an outage; control power isn t required. Open interrupters are mechanically prevented from closing. Pull the CLOSE lever down once for the first closing profile. Pull the lever twice for the second closing profile. Control power must be available. Interrupter OPEN/CLOSED indicator on each phase is large and reflective for easy viewing, day or night. It s attached directly to the operating rod no complicated linkage to break. Figure 21. Interrupter OPEN/CLOSED indicator, one at each pole. Left: Red (closed) target. Right: Green (open) target. Reversed-color targets are optionally available. Figure 20. Interrupter OPEN/CLOSE/READY lever. Top: Opening interrupters. Bottom: Closing interrupters. Figure 22. Disconnect OPEN/CLOSE lever, which can only be operated when interrupters are open. 17

18 HOT-LINE TAG LEVER for setting and releasing tags for energized line work. A tag can be set locally using the lever or the secure Wi-Fi communication link, or remotely using SCADA. Normally, a tag is removed the same way it was applied. However, the lever can be used to remove remotely set tags too. This approach meets NESC 442.E requirements, which allow local removal of a remotely set tag if local indication of the tag is provided a HOT-LINE TAG indicator is furnished on the protection and control module. GROUND-TRIP BLOCK lever for temporarily blocking ground overcurrent protection elements when bypassing IntelliRupter fault interrupter. Can optionally also block sensitive-earth overcurrent elements and circuit testing. Figure 23. HOT-LINE TAG lever. Left: Manually applying hot-line tag. Right: Hot-line tag applied and tagged. Figure 24. GROUND-TRIP BLOCK lever. Left: Applying ground-trip blocking. Right: Ground-trip blocking applied and tagged. 18

19 Optional external trip interface. The external trip interface allows hardwire connections from the substation equipment to be decoded and sent to the control through an optical connection, providing complete electrical isolation between the substation control voltages and the IntelliRupter control system. Integrating the IntelliRupter fault interrupter into the substations allows S&C s PulseClosing Technology to directly protect substation transformers. This feature will allow connections to backup relays, transformer and bus differential protection relays, control house indicators, switches, and other substation protection, allowing it to be tripped at protection speeds for these applications. This feature has been designed to work with S&C s IntelliTeam SG Automatic Restoration System, allowing the substation protection to integrate seamlessly with the industry s fastest self-healing system. In addition to the substation application, this new feature also opens opportunities for integrating with distributed energy resources because the IntelliRupter fault interrupter s accurate sensors and directional protection capabilities make it an ideal choice for those applications. The external trip feature provides six inputs and five outputs. See Table 1 for a list of the inputs and outputs with their functional descriptions. The customer interface will accept dc voltages ranging from 19 Vdc to 180 Vdc, allowing it to operate with 24-V, 48-V, and 125-V substation batteries. It can also operate from 102 Vac to 208 Vac. Table 1. Input/Output Descriptions Type Name Description Input Open Sends an open command to the control; the IntelliTeam system will treat this as a manual operation Input Trip Sends an open command to the control; the IntelliTeam system will treat this as a protection operation Input Close Sends a close command to the control Input Hot Line Tag Applies Hot Line Tag Input Ground Trip Block Applies Ground Trip Block Input Maintenance Mode Prevents all operation of the IntelliRupter fault interrupter; satisfies the requirements for the ANSI Device Designation 69 Output Open Contacts closed when the IntelliRupter fault interrupter is open Output Close Contacts closed when the IntelliRupter fault interrupter is closed Output Hot Line Tag Contacts closed when Hot Line Tag has been applied by the manual lever, IntelliLink software, through SCADA, or the external interface Output Ground Trip Block Contacts closed when Ground Trip Block has been applied by the manual lever, IntelliLink software, through SCADA, or the external interface Output Error Contacts closed when the link between the control and customer interface is not functioning or when the control is in an error state 19

20 Blade cover Tap cover Figure 25. Optional wildlife protection. Reduces wildlife-related nuisance outages. Figure 27. Optional bracket-mounted antenna. Extends four feet from the base; attaches at either end. Includes 900 MHz, 3 dbd-gain omnidirectional antenna or 900 MHz, 9 dbd gain directional Yagi antenna, plus cable and hardware. Also available: bracket only. For other options and ratings, see S&C Specification Bulletins and 766A-31. Figure 26. Optional MacLean Power Systems Zforce Type ZHP (Heavy Duty) polymer-housed metal-oxide surge arresters. Factory-installed and wired. 20

21 Construction of IntelliRupter Fault Interrupters for Underground System Applications B A C D E Figure 28. A Disconnect Pad-Mounted Style IntelliRupter fault interrupter, rated 15.5 kv maximum. A Protection and Control Module and Communication Module is located in low-voltage compartment. B C Interrupter OPEN/CLOSE/READY lever. See Figures 29 and 30. D Interlock lever bar provides means to lock interrupters in open position. E Visible load-break disconnect. Ground trip block and hot-line tag are located in low-voltage compartment. 60-Hertz Ratings kv Amperes, RMS Minimum Maximum BIL Continuous Interrupting, Symmetrical

22 Interrupter OPEN/CLOSE/READY lever for manually opening and closing interrupters. To open the interrupters, slide the interlock bar to the right and pull the interrupter OPEN/CLOSE/READY lever forward. The Open position can be tagged, if desired, by sliding interlock bar to the left with the interrupter open/close/ready lever in the Open position. Interrupters can be tripped during an outage; control power isn t required. Open interrupters are mechanically prevented from closing. Figure 29. Interrupter OPEN/CLOSE/READY lever in the Open position. To close the interrupters, slide the interlock bar to the left with interrupter OPEN/CLOSE/ READY lever in the Ready position. Then, push the interrupter OPEN/CLOSE/READY lever forward once for the first closing profile. Push the interrupter OPEN/CLOSE/READY lever forward twice for the second closing profile. Control power must be available. Figure 30. Left: Interrupter OPEN/CLOSE/READY lever in Ready position. Right: Interrupter OPEN/CLOSE/READY lever in Close position. 22

23 Accessories Figure 31. Module handle fitting. Attaches to the hookstick with universal fitting. Permits field installation and removal of protection and control module and communication module. Includes prong tor operating lntellirupter fault interrupter levers. Figure 34. Module stub handle. Permits installation and removal of the protection and control module and communication module in your service center or Iab. When permitted by utility operating practice, can be used by a gloved individual to install and remove modules in the field. External power supply connector Figure 32. Wi-Fi tester. Simulates connection to communication module. Confirms your laptop computer can establish secure Wi-Fi connection to the lntellirupter fault interrupter. Also demonstrates use of Wi-Fi security keys. For indoor use only. Figure 35. Power supply. Powers the protection and control module and communication module, installed in the base or low-voltage compartment in your service center or lab. Permits open, close, and pulsing operations, preinstallation uploading and downloading of configuration settings, programming of radio, and charging of radio batteries, as applicable. For indoor use only. Figure 33. Docking station. Powers the protection and control module and communication module, removed from the base or low-voltage compartment in your service center or lab. Permits pre-installation uploading and downloading of configuration settings, programming of radio, and charging of radio batteries, as applicable. For indoor use only. Other Accessories: Spare 12-Vdc, 8-Ampere-hour battery pack for communication module. Battery charger output harness. For connecting battery pack to an 800-mA, current-limited 12-Vdc lead-acid battery charger. Detailed instruction manual. Includes printed copies of all IntelliRupter fault interrupter instruction sheets, erection drawings, and reference drawings. 23

24 Why Choose IntelliRupters Fault Interrupters Instead of Conventional Reclosers? Consider all the important features included as standard on IntelliRupter PulseCloser Fault Interrupters that are either unavailable or only available at substantial additional cost on conventional reclosers. IntelliRupter fault interrupter is clearly the intelligent choice. Table 2. IntelliRupter Fault Interrupter Features and Benefits Standard Feature PulseClosing Technology PulseFinding Fault Location Technique IntelliRupter PulseCloser Fault Interrupter Increases equipment life Eliminates voltage sags Reduces conductor slap Improves coordination Benefits Reduces arc flash energy Allows testing of underground circuits Conventional Reclosers Not available Simplifies coordination Improves segmentation Not possible Intelligent Fuse Saving Capability Reduces number of disturbances on a feeder Improves SAIDI without negatively impacting MAIFI Not possible IntelliTeam SG Automatic Restoration System Capability Improves reliability in critical areas of distribution system Quickly initiates service restoration after a fault Requires S&C IntelliNode Interface Module Loop Restoration Capability Improves reliability of looped circuits Eliminates voltage sags Possible, but without PulseClosing Technology Automatic Source-Transfer Capability Improves reliability of facilities with critical loads May require optional hardware Variety of Single-Phase and Three-Phase Tripping and Lockout Capabilities Easy tailored to the requirements of each application Can reduce number of disturbances on a feeder, improving MAIFI Optional, if possible Wi-Fi Communication and Configuration Permits configuration and operation from the security of your vehicle Extensive security features prevent unauthorized access Optional High-Resolution Waveform Capture and Viewing Software with GPS Time Stamping Speed post-event analysis Typically lower resolution. GPS time stamping is optional High-Accuracy Integrated Current Sensing and Voltage Sensing on Both Sides of Device Self-Powered ±0.5% current sensing accuracy, for load currents through fault currents ±0.5% voltage sensing accuracy Eliminates cost of potential transformer and fusing Simplifies grounding Eliminates cost of sensor mountings and cables Simplifies grounding Reduces installation time and cost Reduces installation time and cost Limited-range integrated current sensing may be optionally available. High-accuracy integrated voltage sensing may be optionally available Optional Base-Mounted Controls Eliminates cost of control enclosure and cables Simplifies grounding Reduces installation time and cost Not available Integrated Disconnect Models Cuts installation time Interlocked operation Position is reported to SCADA Not available Quick Installation Ten-Year Control Warranty Single-point lifting eliminates need for framing Includes mounting bracket Heightens confidence in quality of the control No enclosure to mount Simplifies antenna connection Factory installed and wired surge arrestors are optional Ten-year hardware warranty is optional Installation typically takes twice as long. Mounting bracket is optional. Surge arresters may not be available Ten-year warranty on certain controls only. Ten-year warranty on hardware is not available For more information on Intelligent Fuse Saving, see A New Fuse-Saving Philosophy on S&C s website, sandc.com/newfusesaving. 24

25 Let S&C s Power Systems Solutions Professionals Help You Maximize the Benefits of IntelliRupter Fault Interrupter and IntelliTeam SG Automatic Restoration System The IntelliRupter fault interrupter and an IntelliTeam SG system will completely change the way you think about designing distribution systems for reliability and optimum functionality. S&C s Power Systems Solutions team of automation, system planning, and engineering experts have extensive experience helping electric utilities apply S&C s automation tools. They can get you up to speed quickly avoiding the time-consuming learning curve that might otherwise be required. Using their experience with S&C s IntelliRupter fault interrupter and the IntelliTeam SG system, the Power Systems Solutions team has developed approaches for fully integrating distribution automation into even the most complex circuit configurations, ensuring your system works right the first time. They ll help you apply the IntelliRupter fault interrupter and IntelliTeam SG system to: Improve reliability Defer capital expenditures Reduce costs Manage aging assets Key considerations in the evaluation process include: Analysis of costs versus benefits Review of load levels and transfer capacity Determination of critical customer needs Determination of geographic concerns Determination of reliability impacts S&C can also provide critical engineering and field service expertise to ensure successful implementation of your distribution automation solution, including: Engineering Services Coordination studies to evaluate protection settings End-to-end communication system design to make sure your system works right, today and in the future IntelliTeam SG factory acceptance testing, which simulates your system to ensure automation design performs as expected IntelliTeam SG site automation testing, which simulates events on site to ensure automation settings and demonstrate communication infrastructure functionality 25

26 Field Services Communication surveys SCADA integration Commissioning Training Engineering, Procurement, Construction (EPC) Services Project management Construction management And S&C can provide services to evaluate the performance of your IntelliRupter fault interrupters and IntelliTeam SG system after commissioning, including: System inspection and data collection Remote monitoring for system health reports System event evaluation System communication evaluation Post-installation benefit analysis No other supplier offers the latest in distribution automation technology plus assistance in applying and implementing this technology so you ll realize the maximum return on your investment. Contact your local S&C Sales Office today for more information. 26

27

28 Descriptive Bulletin January 15, 2018 S&C Electric Company , all rights reserved Offices Worldwide sandc.com

S&C IntelliRupter PulseCloser. Outdoor Distribution 14.4 kv and 25 kv

S&C IntelliRupter PulseCloser. Outdoor Distribution 14.4 kv and 25 kv S&C IntelliRupter PulseCloser Outdoor Distribution 14.4 kv and 25 kv Descriptive Bulletin 766-30 February 7, 2006 New Publication 2006 IntelliRupter PulseCloser Tomorrow s Technology Available Now S&C

More information

S&C IntelliRupter PulseCloser Fault Interrupter Overhead Source-Transfer Application

S&C IntelliRupter PulseCloser Fault Interrupter Overhead Source-Transfer Application Overhead Source-Transfer Application Detailed Functional Specification Guide 1.0 GENERAL 1.01 The automated distribution fault-interrupting system shall conform to the following specification. 1.02 The

More information

S&C IntelliRupter PulseCloser Outdoor Distribution (15.5 kv and 27 kv)

S&C IntelliRupter PulseCloser Outdoor Distribution (15.5 kv and 27 kv) Outdo Distribution (15.5 kv and 27 kv) Detailed Functional Specification Guide 1.0 GENERAL 1.01 The automated distribution fault interrupting system shall confm to the following specification. 1.02 The

More information

S&C 6801M Automatic Switch Operator

S&C 6801M Automatic Switch Operator S&C 6801M Automatic Switch Operator for Overhead Distribution Switches and Disconnects Simple, Economical Switch Automation S&C s 6801M Automatic Switch Operators make it easy to automate new or existing

More information

Specifications. S&C Pad-Mounted Style IntelliRupter PulseCloser Fault Interrupter Outdoor Distribution (15.5 kv and 27 kv)

Specifications. S&C Pad-Mounted Style IntelliRupter PulseCloser Fault Interrupter Outdoor Distribution (15.5 kv and 27 kv) Outdoor Distribution (155 kv and 27 kv) Specifications Conditions of Sale STANDARD: The seller s standard conditions of sale set forth in Price Sheets 150 and 181 apply, except as modified by the SPECIAL

More information

Product Description. S&C IntelliNode Interface Module. Table of Contents. Instruction Sheet

Product Description. S&C IntelliNode Interface Module. Table of Contents. Instruction Sheet S&C IntelliNode Interface Module Product Description Table of Contents Section Page Section Page Introduction Qualified Persons.......................... 2 Read this Instruction Sheet..................

More information

IntelliTeam II Automatic Restoration System

IntelliTeam II Automatic Restoration System No system is too complex to automate with... IntelliTeam II Automatic Restoration System Introduced in 1997, the IntelliTeam Automatic Restoration System was the first product of its kind. Using peer-to-peer

More information

2012 Grid of the Future Symposium. Demonstration of Pulsecloser Applications and Benefits in Ameren s Distribution Automation Program

2012 Grid of the Future Symposium. Demonstration of Pulsecloser Applications and Benefits in Ameren s Distribution Automation Program 21, rue d Artois, F-75008 PARIS CIGRE US National Committee http : //www.cigre.org 2012 Grid of the Future Symposium Demonstration of Pulsecloser Applications and Benefits in Ameren s Distribution Automation

More information

DNP Points List and Implementation

DNP Points List and Implementation S&C IntelliRupter PulseCloser Fault Interrupter Outdoor Distribution (15.5 kv, 27 kv, and 38 kv) DNP Points List and Implementation Table of Contents Section Page Section Page Introduction...1 Status Points...2

More information

Elastimold Molded Vacuum Recloser - MVR

Elastimold Molded Vacuum Recloser - MVR Subject: Elastimold Recloser Technical Specification Date: 4/24/12 File: MVR-RS-0412 Page: 1 of 6 1.0 SCOPE Elastimold Molded Vacuum Recloser - MVR 1.1 This specification covers electrical and mechanical

More information

Primary Injection Test Procedure

Primary Injection Test Procedure S&C IntelliRupter PulseCloser Fault Interrupter Outdoor Distribution (15.5 kv, 27 kv, and 38 kv) Primary Injection Test Procedure Table of Contents Section Page Section Page Introduction Qualified Persons....

More information

Products Portfolio. Pole mounted Vacuum Recloser

Products Portfolio. Pole mounted Vacuum Recloser Products Portfolio Pole mounted Vacuum Recloser Efacec Switchgear Efacec Switchgear is a leading company in Portugal and a worldwide reference in the development of solutions for power generation, transmission,

More information

Advanced Fuse-Saving Techniques. T. ROUSAN Ameren Illinois USA. J. JERMAKOWICZ S&C Electric Company USA

Advanced Fuse-Saving Techniques. T. ROUSAN Ameren Illinois USA. J. JERMAKOWICZ S&C Electric Company USA 21, rue d Artois, F-75008 PARIS CIGRE US National Committee http : //www.cigre.org 2015 Grid of the Future Symposium Advanced Fuse-Saving Techniques T. ROUSAN Ameren Illinois USA J. JERMAKOWICZ S&C Electric

More information

Installation. Section Page Section Page NOTICE

Installation. Section Page Section Page NOTICE S&C IntelliRupter PulseCloser Fault Interrupter Outdoor Distribution (15.5 kv, 27 kv, and 38 kv) Installation Table of Contents Section Page Section Page Introduction Qualified Persons.... 2 Read this

More information

S&C Scada-Mate Switching Systems Outdoor Distribution (14.4 kv through 34.5 kv)

S&C Scada-Mate Switching Systems Outdoor Distribution (14.4 kv through 34.5 kv) Outdo Distribution (14.4 kv through 34.5 kv) Detailed Functional Specification Guide 1.0 GENERAL 1.01 The automated distribution switching system shall confm to the following specification. 1.02 The loadbreak

More information

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage Overhead solutions Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage Overhead switching products Brochure Your outdoor overhead distribution

More information

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV 16346-1 3a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

DNP Points List and Implementation

DNP Points List and Implementation S&C 6800 Series Automatic Switch Control DNP Points List and Implementation Table of Contents Section Page Section Page DNP Points List for 6801 Controls...1 6801 Status Points...2 6801 Double-bit Status

More information

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical Issued for Review Section 26 28 16.01 Air Circuit Breakers Page 1 of 7 PART 1 GENERAL 1.1 GENERAL.1 This specification serves to define requirements for a replacement of low voltage circuit breaker of

More information

Operation. S&C IntelliRupter PulseCloser Fault Interrupter Outdoor Distribution (15.5 kv, 27 kv, and 38 kv) Table of Contents

Operation. S&C IntelliRupter PulseCloser Fault Interrupter Outdoor Distribution (15.5 kv, 27 kv, and 38 kv) Table of Contents S&C IntelliRupter PulseCloser Fault Interrupter Outdoor Distribution (15.5 kv, 27 kv, and 38 kv) Operation Table of Contents Section Page Section Page Introduction Qualified Persons.... 2 Read this Instruction

More information

DNP Points List and Implementation for Universal Controls

DNP Points List and Implementation for Universal Controls S&C 6800 Series Automatic Switch Control DNP Points List and Implementation for Universal Controls Table of Contents Section Page Section Page DNP Points List for 6801 Universal Controls...1 6801 Status

More information

Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3

Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3 www.entecene.co.kr Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3 General features We, ENTEC introduce a Solid Insulated Vacuum Recloser encapsulated with

More information

LineScope. Smart Power Monitor. Bulletin DB50C18. US Patent Nos , , and B2

LineScope. Smart Power Monitor. Bulletin DB50C18. US Patent Nos , , and B2 Bulletin DB50C18 LineScope Smart Power Monitor US Patent Nos. 9664710, 9746498, and 9810720B2 14000 Rt. 993, Trafford, PA 15085 p 724-864-4177 f 724-864-9040 e sales@cleavelandprice.com The LineScope Overview

More information

Specifications. S&C Scada-Mate Switching System Outdoor Distribution (14.4 kv through 34.5 kv) For Remote Supervisory Control

Specifications. S&C Scada-Mate Switching System Outdoor Distribution (14.4 kv through 34.5 kv) For Remote Supervisory Control Outdoor Distribution (14.4 kv through 34.5 kv) For Remote Supervisory Control Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheets 150 and 181 apply,

More information

ENhanced TEChnology. Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1

ENhanced TEChnology.   Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1 ENhanced TEChnology www.entecene.co.kr Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1 General features We, ENTEC introduce a Solid Insulated Vacuum Recloser encapsulated

More information

Specif ications. S&C Remote Supervisory Vista Underground Distribution Switchgear Outdoor Distribution (15.5 kv through 38 kv)

Specif ications. S&C Remote Supervisory Vista Underground Distribution Switchgear Outdoor Distribution (15.5 kv through 38 kv) Outdoor Distribution (15.5 kv through 38 kv) Specif ications Conditions of Sale STANDARD: The seller s standard conditions of sale set forth in Price Sheet 150 apply, except as modified under "SPECIAL

More information

Maximizing protection coordination with self-healing technology

Maximizing protection coordination with self-healing technology Supersedes December 2011 Daniel P. Roth, Distribution Automation Technical Manager, Eaton s Cooper Power Systems Abstract Much of the Smart Grid initiative includes the installation of new recloser and

More information

Medium Voltage Metal-Enclosed Power Capacitor Banks

Medium Voltage Metal-Enclosed Power Capacitor Banks 66 Carey Road Queensbury, NY 12804 Ph: (518) 792-4776 Fax: (518) 792-5767 www.nepsi.com sales@nepsi.com Medium Voltage Metal-Enclosed Power Capacitor Banks General Northeast Power System s (NEPSI's) medium

More information

Specifications. S&C IntelliNode Interface Modules. Conditions of Sale

Specifications. S&C IntelliNode Interface Modules. Conditions of Sale Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheets 150 and 181 apply, except as modified by the SPECIAL WARRANTY PROVISIONS and WARRANTY QUALIFICATIONS

More information

Source-Transfer Application Guide

Source-Transfer Application Guide S&C Model 6802 Automatic Switch Control Source-Transfer Application Guide Table of Contents Section Page Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this

More information

Siemens FuseSaver New half-cycle circuit breaker for rural smart grids to minimize operating costs of feeder and spur lines

Siemens FuseSaver New half-cycle circuit breaker for rural smart grids to minimize operating costs of feeder and spur lines Siemens FuseSaver New half-cycle circuit breaker for rural smart grids to minimize operating costs of feeder and spur lines Authors: Dr. Brett Watson, Siemens Ltd., PO Box 4833, Loganholme, QLD 4129, Australia

More information

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet Specification sheet PLT Breaker-based transfer switch open, closed or soft transition 800 3000 amps Description PLT breaker-based transfer switches are designed for operation and switching of electrical

More information

Docking Station Instructions

Docking Station Instructions S&C IntelliRupter PulseCloser Fault Interrupter Outdoor Distribution (15.5 kv, 27 kv, and 38 kv) Docking Station Instructions Table of Contents Section Page Section Page Introduction Qualified Persons...

More information

SERIES SD3800 / SD3810 SPECIFICATION

SERIES SD3800 / SD3810 SPECIFICATION SERIES SD3800 / SD3810 SPECIFICATION SOLID DIELECTRIC SINGLE SIDED 15 KV & 25 KV PADMOUNTED VACUUM LOAD INTERRUPTERS AND VACUUM FAULT INTERRUPTERS WITH VISIBLE DISCONNECTS MANUALLY OPERATED / REMOTELY

More information

Medium Voltage Metal-Enclosed Harmonic Filter Systems

Medium Voltage Metal-Enclosed Harmonic Filter Systems 66 Carey Road Queensbury, NY 12804 Ph: (518) 792-4776 Fax: (518) 792-5767 www.nepsi.com sales@nepsi.com Medium Voltage Metal-Enclosed Harmonic Filter Systems General NEPSI s armorvar, medium voltage metal-enclosed

More information

ENhanced TEChnology. Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver.

ENhanced TEChnology.  Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver. ENhanced TEChnology www.entecene.co.kr Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Ver. 081226 General features We, ENTEC introduce a Solid Insulated Vacuum Recloser

More information

INSTALLATION PRODUCTS CAA GROUP OCTOBER 2018 Elastimold. Tru-Break switchgear module

INSTALLATION PRODUCTS CAA GROUP OCTOBER 2018 Elastimold. Tru-Break switchgear module INSTALLATION PRODUCTS CAA GROUP OCTOBER 2018 Elastimold Tru-Break switchgear module Tru-Break switchgear module agenda Design platform and value Product specifications Operation Configuration examples

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

High-Reliability Fault-Clearing System solution. Application Guide. Outdoor Distribution (15.5 kv through 38 kv) S&C ELECTRIC COMPANY

High-Reliability Fault-Clearing System solution. Application Guide. Outdoor Distribution (15.5 kv through 38 kv) S&C ELECTRIC COMPANY S&C Remote Supervisory V ista Outdoor Distribution (15.5 kv through 38 kv) Electric utility customers are increasingly concerned about the frequency and duration of outages they are experiencing, and are

More information

Specif ications. S&C Alduti-Rupter Switches Outdoor Distribution (14.4 kv through 69 kv)

Specif ications. S&C Alduti-Rupter Switches Outdoor Distribution (14.4 kv through 69 kv) S&C Alduti-Rupter Switches Outdoor Distribution ( through 69 ) Specif ications Conditions of Sale STANDARD: The seller s standard conditions of sale set forth in Price Sheet apply, except as modified under

More information

NU-LEC. Loop Automation. Reclosers & Sectionalizers

NU-LEC. Loop Automation. Reclosers & Sectionalizers NU-LEC Loop Automation Reclosers & Sectionalizers 1 NU-LEC LLC NU-LEC LLC is a wholly unit of NU-LEC Industries, Pty, Ltd. Sales and service center for United States, Canada, and the Caribbean. Warehouse

More information

SECTION DISCONNECT SWITCHES

SECTION DISCONNECT SWITCHES SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification

More information

S&C Micro-AT Source-Transfer Controls PHOTO SHEET. For use in S&C Metal-Enclosed Gear

S&C Micro-AT Source-Transfer Controls PHOTO SHEET. For use in S&C Metal-Enclosed Gear S&C Micro-AT Source-Transfer Controls are designed for use in S&C Metal-Enclosed Switchgear and Source- Transfer Pad-Mounted Gear, in conjunction with power-operated S&C Mini-Rupter Switches or S&C Alduti-Rupter

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

FCIs reduce fault-locating times and improve reliability metrics, especially the Customer Average Interruption Duration Index (CAIDI).

FCIs reduce fault-locating times and improve reliability metrics, especially the Customer Average Interruption Duration Index (CAIDI). 1 Intelligent electronic devices (IEDs) are the preferred choice for modernizing the grid. Communication among networks of robust IEDs designed for protection, control, and monitoring (PCM) of the power

More information

S Sectionalizers Types TVS15 and TVS27 Time Voltage Sectionalizer Installation and Operation Instructions. Contents

S Sectionalizers Types TVS15 and TVS27 Time Voltage Sectionalizer Installation and Operation Instructions. Contents Sectionalizers Types TVS15 and TVS27 Time Voltage Sectionalizer Installation and Operation Instructions Service Information S270-30-1 Figure 1. Kyle Type TVS Time-Voltage Sectionalizer. Contents 010032KM

More information

Voltage Sag Simulator

Voltage Sag Simulator For use with all DPI s & VDC s 120/208/240V 50/60Hz LEADERS IN VOLTAGE-DIP PROOFING Contents Introduction to the DPI... 3 Theory of DPI operation... 3 Description -... 4 Operation... 5 Sag Simulation...

More information

Solid Dielectric Switchgear Catalog S-trid13

Solid Dielectric Switchgear Catalog S-trid13 Solid Dielectric Switchgear Providing load and fault interrupting switching for systems rated through 38kV, 800A continuous, 12.5 and 16kA symmetrical interrupting Vault or padmount designs Submersible

More information

Specifications. S&C Scada-Mate CX Switching System Outdoor Distribution (14.4 kv and 25 kv)

Specifications. S&C Scada-Mate CX Switching System Outdoor Distribution (14.4 kv and 25 kv) S&C Scada-Mate CX Switching System Outdoor Distribution (14.4 kv and 25 kv) For Remote Supervisory Control or Automatic Source Transfer Specifications Conditions of Sale STANDARD: Seller s standard conditions

More information

S&C M Series Switch Operator. Sophisticated Microprocessor Control of Overhead Distribution Switches

S&C M Series Switch Operator. Sophisticated Microprocessor Control of Overhead Distribution Switches S&C M Series Switch Operator Sophisticated Microprocessor Control of Overhead Distribution Switches S&C s M Series Switch Operator is a fully integrated, microprocessor-based operator that lets you automate

More information

VisoVac padmount fault interrupter

VisoVac padmount fault interrupter Network Protector Catalog Data CA024003EN New Issue VisoVac padmount fault interrupter General The medium voltage padmount vacuum fault interrupter from Eaton delivers economical, reliable and flexible

More information

PS/IO Circuit Board Retrofit

PS/IO Circuit Board Retrofit S&C 6800 Series Automatic Switch Controls PS/IO Circuit Board Retrofit Table of Contents Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this Instruction Sheet....

More information

1. Coordination of series-rated devices is permitted where indicated on Drawings.

1. Coordination of series-rated devices is permitted where indicated on Drawings. SECTION 16055 - OVERCURRENT PROTECTIVE DEVICE COORDINATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

Product Description. S&C 5800 Series Automatic Switch Control S&C ELECTRIC COMPANY TABLE OF CONTENTS

Product Description. S&C 5800 Series Automatic Switch Control S&C ELECTRIC COMPANY TABLE OF CONTENTS S&C 5800 Series Automatic Switch Control Product Description TABLE OF CONTENTS Section Page INTRODUCTION Qualified Persons............................... 2 Read this Instruction Sheet.......................

More information

OSM PRODUCT GUIDE. OSM AUTOMATIC CIRCUIT RECLOSER 15kV, 27kV & 38kV Models

OSM PRODUCT GUIDE. OSM AUTOMATIC CIRCUIT RECLOSER 15kV, 27kV & 38kV Models OSM PRODUCT GUIDE OSM AUTOMATIC CIRCUIT RECLOSER 15kV, 27kV & 38kV Models 1. Product Guide OSM Automatic Circuit Recloser 15kV 27kV 38kV Models Introduction INTRODUCTION The OSM15, OSM27 and OSM38 automatic

More information

SmartClose 3-phase, Synchronous Close Vacuum Capacitor Switch

SmartClose 3-phase, Synchronous Close Vacuum Capacitor Switch installation instructions SmartClose 3-phase, Synchronous Close Vacuum Capacitor Switch 2013 Hubbell Incorporated hpsliterature@hubbbell.com hubbbellpowersystems.com The equipment covered by these installation

More information

7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching

7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching 7000 SERIES Power Switching Solutions Fig. 2: Four pole, Closed Transition Switch rated 1000 Amperes in Type 1 enclosure. Closed Transition Switching Closed Transition Switches feature main contacts that

More information

Diamondback. Solid Dielectric Load Break Switch Catalog. Distributed By;

Diamondback. Solid Dielectric Load Break Switch Catalog. Distributed By; Solid Dielectric Load Break Switch Catalog Distributed By; p G&W headquarters in Bolingbrook, IL USA Company profile Since 1905, G&W Electric has helped energize the world with innovative power system

More information

MiCOM P122C Time-Overcurrent Protection

MiCOM P122C Time-Overcurrent Protection Protection Relays 01 MiCOM P122C Time-Overcurrent Protection Customer Benefits 1A/5A software setting 4 function keys Compact unit for flush and wall-surface mounting Comprehensive measurements Disturbance

More information

What is a Deadfront and Separable Arrester

What is a Deadfront and Separable Arrester What is a Deadfront and Separable Arrester ArresterFacts 025 What are Deadfront and Separable Arresters Photo ArresterWorks Separable Arrester sketch Courtesy Tyco Electronics Deadfront Arrester Photo

More information

Solid Dielectric Switchgear

Solid Dielectric Switchgear CATALOG GW5-TS09 MARCH, 2009 Solid Dielectric Switchgear Providing load and fault interrupting switching for systems rated through 38kV, 800A continuous, 12.5kA symmetrical interrupting Submersible vault

More information

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM Engineering Specification Electrical Networks TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V Version: 1 Issued: March 2014 Owner: Electrical Networks Asset

More information

Siemens Fusesaver and Remote Control Unit 3AD8

Siemens Fusesaver and Remote Control Unit 3AD8 Catalog HG 11.43 Edition 2017 Siemens Fusesaver and Remote Control Unit 3AD8 Medium-Voltage Equipment siemens.com/fusesaver 2 Siemens Fusesaver and Remote Control Unit 3AD8 Siemens HG 11.43 2017 R-HG11-FR-001.tif

More information

Operating and Diagnostic Instructions for IntelliTeam SG Automatic Restoration System

Operating and Diagnostic Instructions for IntelliTeam SG Automatic Restoration System S&C IntelliRupter PulseCloser Fault Interrupter Outdoor Distribution (15.5 kv, 27 kv, and 38 kv) Operating and Diagnostic Instructions for IntelliTeam SG Automatic Restoration System Table of Contents

More information

PTAD Poletop Motor and Controller for Unitized Overhead Switches

PTAD Poletop Motor and Controller for Unitized Overhead Switches Bulletin DB-38A09 PTAD Poletop Motor and Controller for Unitized Overhead Switches 14000 Rt. 993, Trafford, PA 15085 (724) 864-4177 FAX (724) 864-9040 E-mail: sales@cleavelandprice.com Poletop Switch Motor

More information

Specifications. S&C Micro-AT Source-Transfer Control. In Weatherproof Enclosure

Specifications. S&C Micro-AT Source-Transfer Control. In Weatherproof Enclosure In Weatherproof Enclosure Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply. SPECIAL TO THIS PRODUCT: APPLICATION NOTE: The S&C Micro-AT

More information

Voltage Dip-Proofing Inverter

Voltage Dip-Proofing Inverter Voltage Dip-Proofing Inverter DPI54S / 54L Series Models 120V & 208/230 50/60Hz Contents: Introduction...3 Theory of operation...3 Specifications...5 Up-time considerations...6 Installation Guide...7 Test

More information

New Tools for Managing Smart Switching Devices. C.A. MCCARTHY S&C Electric Company USA

New Tools for Managing Smart Switching Devices. C.A. MCCARTHY S&C Electric Company USA 21, rue d Artois, F-75008 PARIS CIGRE US National Committee http : //www.cigre.org 2014 Grid of the Future Symposium New Tools for Managing Smart Switching Devices C.A. MCCARTHY S&C Electric Company USA

More information

ELG4125: System Protection

ELG4125: System Protection ELG4125: System Protection System Protection Any power system is prone to 'faults', (also called short-circuits), which occur mostly as a result of insulation failure and sometimes due to external causes.

More information

Electrical Demand Specification (Reference SOP: )

Electrical Demand Specification (Reference SOP: ) Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3

More information

MiCOM P521. Fast Feeder Differential Protection

MiCOM P521. Fast Feeder Differential Protection 01 Fast Feeder Differential Protection The relay provides high-speed two-ended current differential unit protection of overhead lines and underground cables in applications such as ring mains and parallel

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................

More information

Grid Automation packaged solutions Optimal automation of medium voltage grids

Grid Automation packaged solutions Optimal automation of medium voltage grids Grid Automation packaged solutions Optimal automation of medium voltage grids Application principles of the Zone concept Grid Automation (GA) packaged solutions The zone concept offers a method to analyze

More information

Quantum Chargers Enhanced AC Line Transient Immunity

Quantum Chargers Enhanced AC Line Transient Immunity Introduction Quantum Chargers Enhanced AC Line Transient Immunity By: Nasser Kutkut, PhD, DBA Advanced Charging Technologies Inc. This white paper outlines the most common AC power quality disturbances

More information

Square D Meter Centers. A Comprehensive. Selection. Time-Saving, Reliable. Solutions

Square D Meter Centers. A Comprehensive. Selection. Time-Saving, Reliable. Solutions Square D Meter Centers A Comprehensive Selection of Time-Saving, Reliable Solutions VERSATILITY. DESIGN SUPERIORITY. SELECTION. Installation simplicity. The largest selection of meter centers in the industry.

More information

Voltage Dip-Proofing Inverter

Voltage Dip-Proofing Inverter Voltage Dip-Proofing Inverter DPI53S / 54L Series Models 120V & 208/230 50/60Hz LEADERS IN VOLTAGE DIP-PROOFING Contents: Introduction...3 Theory of operation...3 Specifications...5 Up-time considerations...6

More information

Rapier GX Gas Enclosed Load Break Switch and Sectionaliser up to 38kV with automation or remote control options ENGINEERING BRILLIANT SOLUTIONS

Rapier GX Gas Enclosed Load Break Switch and Sectionaliser up to 38kV with automation or remote control options ENGINEERING BRILLIANT SOLUTIONS Rapier GX Gas Enclosed Load Break Switch and Sectionaliser up to 38kV with automation or remote control options ENGINEERING BRILLIANT SOLUTIONS RAPIER GX Gas Enclosed Switch Our new RAPIER GX, pole-mounted

More information

PG&E Points List for Universal Controls

PG&E Points List for Universal Controls S&C 6800 Series Automatic Switch Control PG&E Points List for Universal Controls Table of Contents Section Page Section Page PG&E Points List for 6802/3 Universal Controls. 1 Response Limit...2 6802/3U

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................

More information

Industries. Switchgear Interlock Applications. Process safety Control. Power Distribution Power Generation Power Transmission.

Industries. Switchgear Interlock Applications. Process safety Control. Power Distribution Power Generation Power Transmission. Switchgear Interlock Applications Data Sheet Industries Power Distribution Power Generation Power Transmission Type DM Access Interlock with Spring Bolt Type PPS Interlock Quick-Trip ARC Flash Reduction

More information

MV overhead feeder automation

MV overhead feeder automation MV overhead feeder automation by John Cossey, Nu-Lec Industries Electricity providers are under immense pressure to improve the reliability of supply to their customers. Providers have a number of options

More information

5800 Series Non-IntelliTEAM Universal Automatic Switch Control PG&E SCADA Points List

5800 Series Non-IntelliTEAM Universal Automatic Switch Control PG&E SCADA Points List S&C Electric Company 5800 Series Non-IntelliTEAM Universal 5800 Series Non-IntelliTEAM Universal PG&E SCADA Points List PG&E SCADA Points List for: 5801 Universal Control with USBP0S0X Software and 5802

More information

WiAutoLink Frequently Asked Questions

WiAutoLink Frequently Asked Questions Rev. 0 December 2014 Page 1 of 8 WiAutoLink Frequently Asked Questions December 2014 1 Rev. 0 December 2014 Page 2 of 8 Table of Contents 1 Background... 4 1.1 What is the WiAutoLink Single Phase Electronic

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

Specifications. S&C IntelliNode Interface Modules

Specifications. S&C IntelliNode Interface Modules Specifications Conditions of Sale STANDARD: The seller s standard conditions of sale set forth in Price Sheets 150 and 181 apply, except as modified by the SPECIAL WARRANTY PROVISIONS and WARRANTY QUALIFICATIONS

More information

Loop Automation. Technical Manual for the ADVC Controller Range

Loop Automation. Technical Manual for the ADVC Controller Range Loop Automation Technical Manual for the ADVC Controller Range Contents List of Figures 5 List of Tables 7 Acronyms 7 Symbols 7 Introduction 8 About this Manual 8 ADVC Controller Firmware Version 9 WSOS

More information

Current Limiting Protector

Current Limiting Protector CLiP Current Limiting Protector For systems rated 2.8-38kV, and continuous currents through 5000A Arc Flash and Arc Blast Reduction Network Protection SCADA Adaptable Indoor or Outdoor Application Professional

More information

DC Outdoor Power Supply/Chargers

DC Outdoor Power Supply/Chargers DC Outdoor Power Supply/Chargers Installation Guide Models Include: WayPoint3 WayPoint7-2.5A @ 12VDC or 24VDC. - 6A @ 12VDC or 24VDC. - 115/230VAC input. - 115VAC input. WayPoint5 WayPoint7V - 4A @ 12VDC

More information

Meter Enclosure and Equipment Standards

Meter Enclosure and Equipment Standards Meter Enclosure and Equipment Standards (a) (b) General Requirements: CITY OF OCALA UTILITY SERVICES METER ENCLOSURE AND EQUIPMENT STANDARDS: (1) To avoid the costs associated with having to replace unacceptable

More information

Redundant Bus Protection Using High-Impedance Differential Relays. Josh LaBlanc

Redundant Bus Protection Using High-Impedance Differential Relays. Josh LaBlanc Redundant Bus Protection Using High-Impedance Differential Relays Josh LaBlanc Purpose Discuss the configuration of the bus under study, and touch on the needs for redundant protection on the bus. Briefly

More information

Wi-Fi and Security Administration

Wi-Fi and Security Administration S&C PulseCloser Fault Interrupter Outdoor Distribution (15.5 kv, 27 kv, and 38 kv) Wi-Fi and Security Administration Table of Contents Section Page Section Page Introduction Qualified Persons...2 Read

More information

It is acceptable to place all required information in the main element (such as G4010) and delete the sub-elements provided in this template.

It is acceptable to place all required information in the main element (such as G4010) and delete the sub-elements provided in this template. 6. ENGINEERING SYSTEMS REQUIREMENTS G40 SITE ELECTRICAL UTILITIES SYSTEMS REQUIREMENTS SITE ELECTRICAL UTILITIES TEMPLATE 02/18 Instructions for using this template: There are template files for each UNIFORMAT

More information

Performance. Reliability. Simplicity. A smarter grid requires an intelligent recloser.

Performance. Reliability. Simplicity. A smarter grid requires an intelligent recloser. NOVA NX-T recloser with Form 6 control COOPER POWER SERIES Performance. Reliability. Simplicity. A smarter grid requires an intelligent recloser. Evolving technology requires smarter solutions up and down

More information

Specifications. S&C 6802 and 6803 Automatic Switch Controls

Specifications. S&C 6802 and 6803 Automatic Switch Controls Specifications Conditions of Sale STANDARD: The seller s standard conditions of sale set forth in Price Sheet 150 apply, except as modified by the SPECIAL WARRANTY PROVISIONS and WARRANTY QUALIFICATIONS

More information

OVP2. The Over-Voltage Protector 2 (OVP2) Technical Literature

OVP2. The Over-Voltage Protector 2 (OVP2) Technical Literature The Over-Voltage Protector 2 (OVP2) Technical Literature INTRODUCTION The Over-Voltage Protector (OVP) design has been established since 1999 as the premier explosion-proof (Division 1) protection device

More information

InHand Wireless. As an important sector of smart grid building, smart distribution network faces the

InHand Wireless. As an important sector of smart grid building, smart distribution network faces the InHand Wireless Overhead Line System Overhead Line Sensor Key Features: Innovative low current (10A) auto power-harvesting technology, maintains network connection and reliable operation Advanced electronic

More information

Substation Automation Products. Line differential protection RED670 Relion 670 series

Substation Automation Products. Line differential protection RED670 Relion 670 series Substation Automation Products Line differential protection RED670 Relion 670 series For maximum reliability of your power system The RED670 IED (Intelligent Electronic Device) is designed for protection,

More information

Specifications. S&C Line-Rupters. For Line and Cable Switching. Outdoor Transmission (115 kv through 230 kv) Conditions of Sale

Specifications. S&C Line-Rupters. For Line and Cable Switching. Outdoor Transmission (115 kv through 230 kv) Conditions of Sale Outdoor Transmission ( kv through 230 kv) For Line and Cable Switching Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply, except as modified

More information

We put the now in knowledge Today s solutions built on a century of innovation and expertise

We put the now in knowledge Today s solutions built on a century of innovation and expertise PRODUCT OVERVIEW We put the now in knowledge Today s solutions built on a century of innovation and expertise Knowledge. It s what helps you make the next right decision about your critical assets. And

More information