Temperature-Guard TG 50 Pt100/Pt Thermocouple J, K, N, S

Size: px
Start display at page:

Download "Temperature-Guard TG 50 Pt100/Pt Thermocouple J, K, N, S"

Transcription

1 Temperature-Guard TG 50 Pt100/Pt Thermocouple J, K, N, S Features M Input Pt100, Pt1000 and Thermocouples J, K, N, S M Measuring range programmable M Basic accuracy 0.1 % +/- 1 Digit M Simulator function M Fault monitoring for break of wire and short-circuit in the measuring circuit M Programmable fault function nalog output min. or max. overflow larm outputs min. or max. function M 4 alarm outputs, relay SPDT M Isolated analog output 0/ m; 0/ V DC M Full 3-port isolation General The Temperature-Guard has inputs for temperature probes RTD (Pt100/Pt1000) and thermocouple J, K, N and S. Simple programming, up to 4 alarm outputs (SPDT) and optional available fully isolated free programmable analog output 0/ m; 0/ V DC offers a lot of solutions for temperature monitoring. Peak value indication for minimum and maximum measured temperature are stored in the background and can be read out from the display at any time. Short information Programming The device is programmed by frontal buttons, in connection with the LCD display. Inputs RTD (Pt100/Pt1000), 3-wire connection or thermocouple type J, K, N or S. larm outputs The alarm outputs can be programmed as max. or min. function. Switch-on delay and switch-off delay time is programmable from 1 s up to 9 h. The switching status is displayed through LED s. Fault function fault in the measuring circuit could be monitored (break of wire/short-circuit). The switching function of the analog and alarm output(s) is programmable in case of an fault

2 Technical data Power supply Supply voltage : 230 V C ±10 %, 115 V C ±10 %, or 24 V DC ±15 % Power consumption : < 5 V Operating temperature : C ( F) Rated voltage : 250 VC acc. to EN between input/relay output/analog output/supply voltage degree of pollution 2, overvoltage category III Test voltage : 4 kv DC between input/relay output/analog output/supply voltage -conformity Standardize IEC /2004 IEC (ESD) IEC (E-field) IEC (Magnetic filed) IEC (Voltage dip) IEC (Burst) IEC (Surge) IEC (HF current feed) IEC (Burst) IEC (Surge) IEC (HF current feed) IEC (Burst) IEC (Surge) IEC (HF current feed) Case C power supply connection DC power supply connection Input/output, signal/control 4 kv/8 kv contact/air 10 V/m 30 /m 0.5 period, ±100% 2 kv 1 kv L/N, 2 kv L,N/PE 3 V 2 kv 1 kv L/N, 2 kv L,N/PE 3 V 1 kv 1 kv L/N/PE 3 V Result B dispensed with B CISPR16-1/16-2 Radiated interference Passed Inputs Fault detection : Break of wire (RTD,Thermocouple) and short-circuit (only RTD) Input : Pt100 (3-wire) C / C Pt1000 (3-wire) C / C : Thermo couple (TC) Type J C / C Type K C Type N C Type S C cold junction compensation integrated Basic accuracy : <0.1 %, ±1 Digit Temperature coefficient : 0.01 %/K Outputs larm outputs 1-4 nalog output ccuracy Fault function : Relay SPDT < 250 V C < 250 V < 2 cosn 0.3, < 300 V DC < 40 W <2 : 0/ m burden 500 Ω; 0/ V burden >500 Ω, galv. isolated, output changes automatically (burden impedance dependent) : 0.2 %;TK 0.01 %/K : For break of wire or short-circuit detection -belongs to the model- nalog output 0 m, < 3.6 m or > 21.5 m programmable larm output(s) min. or max. function programmable : Graphic LCD- 128x64 pixel, white background illuminated Case : Polyamide (P) 6.6, UL94V-0, DIN rail mounting TS 35 Weight : approx. 450 g Connection : Screw terminals mm² (WG ) Protection : Case IP30, terminals IP20, German BGV 3-2 -

3 Connection diagram Supply voltage nalog output 0/ m, 0/ V DC larm outputs 1-4 Pt100/Pt wire, 2-wire (link terminal 35-36) Thermocouples type J, K, N, S Dimensions Terminals Terminals Terminals Terminals

4 Controls and indicators Device name Measured value Input probe larm output 1 larm output 2 larm output 3 larm output 4 Power-ON LED Parameter button Up/down buttons Description The operation of the device is implemented in 2 levels. The required parameter is called up with the button. The selection within a parameter and the setting-adjustment of a value is implemented with the buttons and. Button combinations (press buttons simultaneously): + 1 parameter back + Parameter is set to "0" or minimum value. fter the switching on the supply voltage, the device initializes itself. In the display the message indicating device type and software version is shown. fter the initialization, the device is running in the working level. The peak value storage is called up and the setpoints of the alarm outputs can be programmed. The configuration level is called up by activation of the button for 2 seconds. In this case, all parameters which determine the properties of the device are programmed. fter the last menu item, or if no button is pressed for longer than 2 minutes, a skip-back into the working level is implemented automatically and the current measured value is indicated in the display. The configuration level can be exited at any time by holding down button for 2 seconds. Error reports In case of occurring faults, the messages are shown on the display in plain text. This simplifies location of the error. See explanation page 10. Operational startup reference! The device is preset with an ex-works default setting. Therefore it must be adapted to each special application. See Page

5 Note on the representation Parameter appears only with corresponding configuration Parameter appears only with corresponding equipment version Working level Description 25.0C Input: Pt100 Temperature 25.0C 1: : : : Input: Pt100 ctual-value displays Change between the two representations for the actual-value display with the buttons and. Only the current value can either be displayed or, in addition, the adjusted values for the switching points of the alarm outputs. This selection is stored and is also retained after a voltage breakdown. Peak value display MX 35.0C MIN 0.0C Reset with Peak value display for minimum and maximum measured value. Deletion of the values with the button or with every power cut-off. Setpoint Fault det. Input larm output 1 MIN Setpoint alarm output 1 (switching function MIN or MX) llocation of the fault detection in the measuring circuit (it belongs to the input; break of wire or short-circuit) Setpoint 20.0C MX Setpoint alarm output 2 (switching function MIN or MX) Setting possible from Digit larm output 2 Note: Setpoints for alarm outputs have to be configured in the same way

6 Configuration level Description (represented values are default settings) 25.0C Working level Input: Pt100 1 Language Input Press 2s 1.1 deutsch english Select language User Language deutsch english 2 Language Input 2.1 Input signal Pt100 Pt1000 Input signal RTD: Pt100 : C/ C Pt1000 : C/ C Thermocouples: Type J : Fe-CuNi C/ C Type K : NiCr-Ni C Type N : NiCrSi-NiSi C Type S : Pt10Rh-Pt C 2.2 Dgital filter Input signal OFF Digital filter OFF or in steps of 0.5 s in the range from s 3 Input 3.1 Contrast 65% contrast Setting possible from % 3.2 Unit C F unit C F Continue page 7-6 -

7 3.3 Decimal place Number of decimal places 0; 0.0 Only available with RTD and thermocouple probe type J. 3.4 Correction 0 C Measured value correction Setting possible from Digit 4 Output 4.1 nalog output 0-20m 4-20m (2-10V) Selection of the analog output 0-20m (0-10 V DC) or 4-20 m (2-10 V DC) utomatic changeover to voltage signal in case of load impedance > 500 Ω. 4.2 Start value 0C Start value analog output Setting possible from Digit nalog output 4.3 End value nalog output 100C End value analog output Setting possible from Digit Note: If start value > end value the output works with a decreasing characterisitc. 4.4 Correct. analog output NO YES Correction analog output NO YES Continue page Continue page 8-7 -

8 4.4.1 Correct. analog output 4.000m Correction start value analog output Setting possible in the range ±2 m or ±1 V Start value (2.000V) Correct. analog output m Correction end value analog output Setting possible in the range ±2 m or ±1 V End value (10.000V) 4.5 Fault action >21 m <3.6 m nalog output (>10.5V) Fault action of the analog output for break of wire or short-circuit in the measuring circuit. > 21m at analog output 0-20/4-20 m <3.6 m at analog output 4-20m (2-10 V) 0 m at analog output 0-20 m (0-10 V) 4.6 larm output 1 OFF Limit Function OFF Function alarm output 1 OFF Limit Monitoring of the measuring value Fault det. Break of wire or short-circuit Limit/Fault det larm output 1 NO NC Switching function Fault det larm output 1 MIN MX Direction of action Switching function alarm output 1 NO, NC Limit Direction of action alarm output 1 MIN, MX Setpoint MX 100C Setpoint alarm output 1 Setting possible from digit larm output 1 Continue page

9 Switching hysteresis 1C Hysteresis alarm output 1 Setting possible from digit larm output Switch-on delay time 0:00:00 h : mm : ss larm output 1 Switch-on delay time alarm output 1 Setting possible from 0:00: :00:00 (h:mm:ss) Switch-off delay time 0:00:00 h : mm : ss larm output 1 Switch-off delay time alarm output 1 Setting possible from 0:00: :00:00 (h:mm:ss) Note: The parameter settings for have to be configured in the same way. 4.7 Simulation 25C Simulation Der works as actuator. The analog output changes in the programmed range. Setting possible in the programmed range This parameter will not be excited automatically after 120 seconds. 5 Output Lock 5.1 Parameter lock OFF CONFIG Parameter lock OFF : no parameters locked CONFIG : Configuration level locked LL : all parameters locked Continue page

10 6 Lock Code 6.1 Factory settings Code 0000 Code for Factory settings 7 Code End 25.0C Return to the working level Input: Pt

11 Error reports Caution! Parameter locked switched on Description The parameter can not be changed, because the parameter lock for the configuration level, or work and configuration level, is switched on. Caution! Undervoltage Supply voltage to low Caution! XX Parameter error Please check t the check-up of the parameter memory, XX errors are detectet. The incorrect parameter are resetted to the factoty settings. Please check and correct parameters if necessary. Caution! XX Parameter error Calibration necessary s before, but the factory settings are incorrect. The device must be checked at works. Change of decimals? Some parameters not representable! dapt parameters automatically? Yes No Change of decimal places While changing number of decimal places, some parameters can be converted, but however, not represented! Selection "No" : Change of the decimal places is not carried out. Selection "Yes" : Decimal places are changed automatically, where the affected parameters are set to the maximum possible value. subsequent verification of the accepted parameters is absolutely necessary. Fault input Input: 9999C Break of wire or short-circuit in the measuring circuit. Text Input: 9999C is flashing

12 Ordering code Input 3 Pt100 Pt1000 Thermocouple 3-wire 3-wire J (Fe-CuNi) K (NiCr-Ni) N (NiCrSi-NiSi) S (Pt10Rh-Pt) C/ C C/ C C/ C C C C 2. larm outputs 2R 2 Relay outputs 3. larm outputs 00 not installed 2R 2 Relay outputs 4. nalog output 00 not installed O nalog output 1, 2; SPDT 3, 4; SPDT 0/ m; 0/ V DC 5. Supply voltage V C V C 5 24 V DC ± 10 % ± 10 % ± 15 % Hz Hz 6. Options 00 without option Works configuration according to customer specifications. 01/08-V

Measuring Amplifier DMS 50 Weight - Force - Pressure - Torque with strain gauges

Measuring Amplifier DMS 50 Weight - Force - Pressure - Torque with strain gauges +49-(0)40-670 73-0 Fax +49-(0)40-670 73-288 info@martens-elektronik.de www.ghm-messtechnik.de Measuring mplifier DMS 50 Weight - Force - Pressure - Torque with strain gauges Features M Bridge sensitivity

More information

Safety Temperature Limiter TT-STL 50

Safety Temperature Limiter TT-STL 50 GmbH Postal address: House address Fon (+49) 0 22 42-8703-0 Postbox 1261 Löhestr. 37 Fax (+49) 0 22 42-8703-20 http: // www.tematec.de 53759 Hennef 53773 Hennef e-mail: team@tematec.de Safety Temperature

More information

Setpoint adjuster SG 9648 Output standard signals 0/ ma or 0/ V DC

Setpoint adjuster SG 9648 Output standard signals 0/ ma or 0/ V DC adjuster SG 9648 Output standard signals 0/4... 20 ma or 0/2... 10 V DC Features M LEDDisplay 14.2 mm red M Display range ± 9999(0) digit M Indicating range and decimal point free programmable M Set point

More information

JUMO Quantum PID100/PID200/PID300

JUMO Quantum PID100/PID200/PID300 Data sheet 702020 Page 1/12 JUMO Quantum PID100/PID200/PID300 Universal PID Controller Series Brief description The Quantum series is available in the three DIN formats 48 mm x 48 mm, 48 mm x 96 mm, and

More information

Standard-Signal-Panelmeter S 9648 Industry standard signals - integrated transmitter-supply - potentiometer

Standard-Signal-Panelmeter S 9648 Industry standard signals - integrated transmitter-supply - potentiometer Martens Elektronik GmbH Kiebitzhörn 18 D22885 Barsbüttel/Germany www.martenselektronik.de F+49(0)40670 730 Fax +49(0)40670 73288 J info@martenselektronik.de StandardSignalPanelmeter S 9648 Industry standard

More information

Setpoint adjuster SG 1010 Output standard signals 0/ ma or 0/ V DC

Setpoint adjuster SG 1010 Output standard signals 0/ ma or 0/ V DC Setpoint adjuster SG 1010 Output standard signals 0/4... 20 ma or 0/2... 10 V DC Features M LEDDisplay 14.2 mm red M Display range ± 9999(0) Digit M Indicating range and decimalpoint programmable M Setpoint

More information

Universal counter UZ 9648 Counting - length measurement - metering - positioning

Universal counter UZ 9648 Counting - length measurement - metering - positioning +49-(0)40-670 73-0 Fax +49-(0)40-670 73-288 info@martens-elektronik.de www.ghm-messtechnik.de Universal counter UZ 9648 Counting - length measurement - metering - positioning Features M LED-Display 14.2mm

More information

Standard Signal Meter S 1010

Standard Signal Meter S 1010 GHMMesstechnik GmbH Standort Martens Kiebitzhörn 18 D22885 Barsbüttel / Germany +49(0)40670 730 Fax +49(0)40670 73288 info@martenselektronik.de www.ghmmesstechnik.de Standard Signal Meter S 1010 Industry

More information

Conductivity-Panelmeter LF 9648 Conductivity measurement with 2-and 4-electrode cells

Conductivity-Panelmeter LF 9648 Conductivity measurement with 2-and 4-electrode cells Conductivity-Panelmeter LF 9648 Conductivity measurement with 2-and 4-electrode cells Features M LED-Display 14.2 mm red M Indicating range 2000(0) Digit M Measuring ranges programmable from 0... 2.000

More information

JUMO diraview 104/108/116/132

JUMO diraview 104/108/116/132 Page 1/19 JUMO diraview 104/108/116/132 Digital indicator Brief description The digital indicator series comprises five freely configurable, universally usable devices in various DIN formats to display

More information

JUMO safetym TB/TW 08 Temperature limiter, monitor as per DIN EN

JUMO safetym TB/TW 08 Temperature limiter, monitor as per DIN EN JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

Tank-Display TA 1010 Content measurement for different formed tanks by hydrostatic pressure or distance measurement Features

Tank-Display TA 1010 Content measurement for different formed tanks by hydrostatic pressure or distance measurement Features +49-(0)40-670 73-0 Fax +49-(0)40-670 73-288 info@martens-elektronik.de www.ghm-messtechnik.de Tank-Display TA 1010 Content measurement for different formed tanks by hydrostatic pressure or distance measurement

More information

Data sheet Video Recorder LINAX A303

Data sheet Video Recorder LINAX A303 1 Technical data 1.1 Input 1.1.1 Analog multi-function input channel 1-6 Measured variable, measuring range To IEC 60873-1: An additional display error of -/+ 1 digit is permitted for every measured value.

More information

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7 M. K. Juchheim GmbH & Co UK USA Jumo Instrument Co. Ltd. Jumo Process Control Inc. 36035 Fulda, Germany Temple Bank, Riverway 735 Fox Chase Phone (0661) 6003-0 Harlow, Essex CM20 2TT Coatesville, PA 19320

More information

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064 Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window

More information

Controller. Applications. Characteristics. Extruder machines Heating control systems Facility engineering Wide range of instrumentation

Controller. Applications. Characteristics. Extruder machines Heating control systems Facility engineering Wide range of instrumentation GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Controller Characteristics System Output Case 2-point-controller, 3-point-controller,

More information

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

MINI MCR-SL-UI-2I(-SP)(-NC)

MINI MCR-SL-UI-2I(-SP)(-NC) Data Sheet 03/2005 Product Description Features Configurable signal duplicator MINI MCR-SL-UI-2I(-SP)(-NC) is used to electrically isolate, condition, amplify, and filter analog standard signals. On the

More information

Paperless recorder Ecograph

Paperless recorder Ecograph Technical information TI075R/09/en Mat. no.: 51001521 Paperless recorder Ecograph Economical and time saving recorder operates without the need for paper or pens and is unusually simple to operate Application

More information

Remote I/O Product Specification

Remote I/O Product Specification Table of Contents 1. Product Overview... 1 1.1 Product List:... 1 1.1.1 Coupler List:... 1 1.1.2 1.1.3 Digital I/O List:... 1 Analog I/O List:... 1 2. Fieldbus Coupler... 2 2.1 CANopen Specifications...

More information

Phase loss monitor CM-PBE Phasemonitor for over and undervoltage CM-PVE Ordering details

Phase loss monitor CM-PBE Phasemonitor for over and undervoltage CM-PVE Ordering details Phase loss monitor CM-PBE Phasemonitor for over and undervoltage CM-PVE 1SVR 550 882 F 9500 CM-PBE Yellow LED - state of relay voltage and single-phase supply voltage for phase failure Monitoring of neutral

More information

TB 45 Temperature limiter / monitor

TB 45 Temperature limiter / monitor TB 45 Temperature limiter / monitor Compact design Suitable for heating and refrigeration processes For all thermocouple types and resistive sensors Display & operating functions Communication functions

More information

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES Two cards providing 8 channels of temperature and process monitoring for VM 600 systems 8 channels of software selectable

More information

JUMO itron 04/08/16/32 Compact microprocessor controllers

JUMO itron 04/08/16/32 Compact microprocessor controllers JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

MINI MCR-SL-PT100-UI(-SP)(-NC)

MINI MCR-SL-PT100-UI(-SP)(-NC) Configurable Temperature Transducer for PT100 Data Sheet 04/2005 Functions MINI MCR-SL-PT100-UI(-SP)(-NC) is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection

More information

Speed indicator DR 1010 Revolution per minute - speed - flow

Speed indicator DR 1010 Revolution per minute - speed - flow Speed indicator DR 1010 Revolution per minute speed flow Features M LEDDisplay 14.2 mm red M Display range 0... 99999 M 0... 3 decimal points or floating point programmable M Inputs for switching contacts,

More information

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS ELK. ETK COMPACT BASIC CONTROL - SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS TIMER - SOFT START OUTPUT

More information

Alarm Unit DG 3200 Control And Monitor Standard Signals

Alarm Unit DG 3200 Control And Monitor Standard Signals Alarm Unit DG 3200 Control And Monitor Standard Signals With the Alarm Unit DG 3200 DRAGO is extending its offer on high-functional and high-reliable components of the interface technique. The Alarm Unit

More information

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet 2CDC 251 113 F0004 CT-AHS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the

More information

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet 2CDC 251 116 F0004 1 5 2 4 3 6 Characteristics Single-function ON-delay and OFF-delay timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the time delay Remote potentiometer

More information

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable 70 Series - Line monitoring relay 70 Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring

More information

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704, EP GFK-2960B November 2017

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704, EP GFK-2960B November 2017 November 2017 Module Status LED Channel Status LEDs Digital Input Connector Ground 24 V DC FE Analog Input Module RSTI-EP Slice I/O Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704,

More information

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features: User Manual M1 Thermocouple type K, B, S, N, E, T, R, L, J Technical features: red display of -1999 9999 digits (optional: green, orange or blue display) minimal installation depth: 97 mm without plug-in

More information

02/11/2015

02/11/2015 DIN Rail Mount 22.5 mm TU2R1 Part number 88865305 Product with 1 relays (88 865 100/103/105/115/125/135/145/155/185/503) : Replaced by the 17,5 mm range For instance : previous part number 88 865 XXX /

More information

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018 September 2018 Module Status LED Channel Status LEDs Digital Input Connector Ground 24 V DC FE Analog Input Module RSTI-EP Slice I/O Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664,

More information

Preset for output value APPLICATIONS

Preset for output value APPLICATIONS UNIFLEX CI 45 Universal transmitter Compact design Display & operating functions Communication features High resolution Fast cycle times Two universal inputs & universal output Two relay outputs Counter/

More information

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet 1SVR 430 221 F7300 2 1 3 Characteristics Switching relay ON-delay approx. 10 ms 1, 2 or 3 c/o contacts Switching relay with gold-plated contacts Width 22.5 mm Approvals e f GOST CCC CT-IRS 1 U/R: green

More information

XU1-DC DC voltage relay. (June 1998) Manual XU1-DC (Revision New)

XU1-DC DC voltage relay. (June 1998) Manual XU1-DC (Revision New) XU1-DC DC voltage relay (June 1998) Manual XU1-DC (Revision New) Woodward Manual XU1-DC GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information

More information

Digital Panel Meters Modular signal s conditioner Type USC-DIN

Digital Panel Meters Modular signal s conditioner Type USC-DIN Digital Panel Meters Modular signal s conditioner Type DIN Linearization of V and A inputs up to 6 points Multiinput modular signal s conditioner 0.% RDG basic accuracy TRMS AC current and voltage measurements

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

XE2 DC current relay for loss of excitation protection. Manual XE2 (Revision A)

XE2 DC current relay for loss of excitation protection. Manual XE2 (Revision A) XE2 DC current relay for loss of excitation protection Manual XE2 (Revision A) Woodward Manual XE2 GB Woodward Governor Company reserves the right to update any portion of this publication at any time.

More information

02/11/2015

02/11/2015 DIN Rail Mount 22.5 mm ETM2 Part number 84874023 Version ETM : Controls temperature of machines using built-in PTC probes Line break or probe short-circuit detection Version ETM2 / ETM22 : Fault latching

More information

08/07/2015

08/07/2015 DIN Rail Mount 22.5 mm TUR1 Part number 88865105 Product with 1 relays (88 865 100/103/105/115/125/135/145/155/185/503) : Replaced by the 17,5 mm range For instance : previous part number 88 865 XXX /

More information

Color hybrid recorder alpha-log

Color hybrid recorder alpha-log Technical Information TI 044R/09/ae/02.96 Part No. 500 74896 Color hybrid recorder alpha-log Universal compact recorder, 1 to 6 analog inputs, with automatic wind up system for 210 ft. (64 m) roll chart

More information

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature Page 1/7 JUMO ecotrans 03 Microprocessor transmitter/ switching device for /Redox voltage and temperature with a 2-line LCD for mounting on a 35 mm DIN rail Brief description Depending on the configuration,

More information

JUMO STB/STW Safety temperature limiter, Safety temperature monitor as per DIN EN 14597

JUMO STB/STW Safety temperature limiter, Safety temperature monitor as per DIN EN 14597 Data heet 701150 age 1/13 JUMO TB/TW afety temperature limiter, afety temperature monitor as per DIN EN 14597 Brief description The safety temperature limiter (TB) and the safety temperature monitor (TW)

More information

Electronic timer CT-ERD.12

Electronic timer CT-ERD.12 2CDC 251 092 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied

More information

Panel Meter Economical Panel Meter for Process, Temperature and Electrical Measurement

Panel Meter Economical Panel Meter for Process, Temperature and Electrical Measurement 8 DN Multisignal Panel Meter Economical Panel Meter for Process, Temperature and Electrical Measurement DP20 TM DP20 meter shown smaller than actual size. OME s new multisignal panel meter delivers high-performance

More information

MINI MCR-SL-UI-REL(-SP)

MINI MCR-SL-UI-REL(-SP) Configurable Threshold Value Switch Data Sheet 11/2004 Method of Operation The configurable 3-way threshold value switch MINI MCR-SL-UI-REL(-SP) is used to control and monitor analog standard signals.

More information

XU1-E Earth fault voltage relay. (August 1996) Manual XU1-E (Revision New)

XU1-E Earth fault voltage relay. (August 1996) Manual XU1-E (Revision New) XU1-E Earth fault voltage relay (August 1996) Manual XU1-E (Revision New) Woodward Manual XU1-E GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information

More information

Contact protection relay

Contact protection relay Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts

More information

TM3TM3 module TM3-2 temperature inputs and 1 analog output

TM3TM3 module TM3-2 temperature inputs and 1 analog output Characteristics module TM3-2 temperature inputs and 1 analog output Main Range of product Product or component type Range compatibility Analogue input number 2 Analogue input type Analogue output number

More information

Limit signalling function for any type of input signal... DESCRIPTION

Limit signalling function for any type of input signal... DESCRIPTION TB 45 Temperature limiter / monitor Compact design Suitable for heating and refrigeration processes For all thermocouple types and resistive sensors Display & operating functions Communication functions

More information

DINALOG A 144 x 36 A1400 Light-Strip Indicator

DINALOG A 144 x 36 A1400 Light-Strip Indicator DINALOG A x 6 A00 Light-Strip Indicator -9-0-0 /.00 Front panel dimensions: x 6 mm Light-strip indicator with 7 high-contrast LEDs Red LED display color Digital display range for portrait format: 999 to

More information

JUMO ctron 04/08/16 Compact controller with timer and ramp function

JUMO ctron 04/08/16 Compact controller with timer and ramp function JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 3603 Fulda, Germany Phone: 49 661 60030 Fax: 49 661 6003607 Email: mail@jumo.net Internet: www.jumo.net JUMO

More information

RE92.CHECKMATE. Dual loop controller for industry purpose. measuring inputs. Automatic parameter selection according to the controlled object

RE92.CHECKMATE. Dual loop controller for industry purpose. measuring inputs. Automatic parameter selection according to the controlled object RE92.CHECKMATE. Dual loop controller for industry purpose. Simple and user-friendly service Safety and reliability guaranteed thanks to: - installation category III - proper galvanic isolation - noise

More information

Installation Instructions Temperature transmitter TAA /00 06/2011

Installation Instructions Temperature transmitter TAA /00 06/2011 Installation Instructions Temperature transmitter TAA431 706042/00 06/2011 Contents 1 Functions and features...3 2 Installation...4 2.1 Addressing...4 2.2 Mechanical installation...4 2.3 Connection to

More information

iologik 4000 Series (M) Modules

iologik 4000 Series (M) Modules iologik 4000 Series (M) s Remote I/O modules Features and Benefits I/O expansion without a backplane Active communication with MX-AOPC UA Server Supports SNMP v1/v2c Easy configuration with Modular ioadmin

More information

Interface technology and switching devices

Interface technology and switching devices Highly compact signal conditioners - MI Analog Pro 3-way signal conditioners Page 326 Highly compact signal conditioners - MI Analog Pro Temperature transducers for resistance thermometers and thermocouples

More information

The Indicator with 3 Limit Contacts

The Indicator with 3 Limit Contacts A 1200 The Indicator with 3 Limit Contacts Format: Installation depth: 96x48 mm (1/8-DIN) 122 mm Description and Operating Manual ELOTECH Industrieelektronik GmbH Verbindungsstrasse 27 D 40723 HILDEN FON

More information

TM3TI4 module TM3-4 inputs temperature

TM3TI4 module TM3-4 inputs temperature Characteristics module TM3-4 inputs temperature Main Range of product Product or component type Range compatibility Analogue input number 4 Analogue input type Complementary Analogue input resolution Permissible

More information

JUMO DICON 401/501 Universal profile controllers/generators

JUMO DICON 401/501 Universal profile controllers/generators JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

VR660 / A200R Programmable Modular Controller System

VR660 / A200R Programmable Modular Controller System consisting of -channel top-hat rail controller modules (VR660) and a display and operating unit (A00R) Local bus Application The VR660 top-hat rail controller permits the design of autarkic, freely programmable

More information

SINGLE-CHANNEL PROCESS INDICATOR series 8001

SINGLE-CHANNEL PROCESS INDICATOR series 8001 SINGLE-CHANNEL PROCESS INDICATOR series 8001 Analog Inputs - all inputs available in one unit - Pt100 RTD type DIN 43 760 or GOST 6651-78 (range from 0 to +600 C) - TC type: J - range from 0 to +600 C

More information

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet 2CDC 251 002 F0003 CT-ERD 6 5 1 2 3 4 1 7 selectable time ranges, from 0.05 s to 100 h, for the adjustment of the time delay 2 Potentiometer with direct reading scale for the fine adjustment of the time

More information

Digital Temperature Controllers MR301/302

Digital Temperature Controllers MR301/302 mikrorem d.o.o. m e r n o r e g u l a c i o n a o p r e m a Digital Temperature Controllers MR301/302 User's Manual doc. 0488A-01/12 "MIKROREM" d.o.o., Braće Spasić 4A, 32000 ČAČAK tel/fax: +381 (32) 370

More information

High-powered control system for sophisticated processes

High-powered control system for sophisticated processes High-powered control system for sophisticated processes regulation control recording visualization easy to use freely configurable integrated PLC telemaintenance network-compatible Gigabit-Ethernet Compact

More information

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

English. Operating manual. Universal transmitter UT125.  Save for later reference. Companies / brands of GHM English Operating manual Universal transmitter UT125 Companies / brands of GHM www.ghm-messtechnik.de Save for later reference. Table of contents page 1. Intended use (areas of application)... 3 1.1 Safety

More information

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web:  -   [! -CMT-10-AO-RC-S [!-] General ordering data Type -CMT-10-AO-RC-S Order No. 1510470000 Version Current-measuring transducer GTIN (EAN) 4050118319583 Qty. 1 pc(s). -CMT-10-AO-RC-S Technical data Dimensions

More information

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet Electronic timer CT-WD 2CDC 251 003 F0003 CT-WD 6 5 1 2 3 4 1 7 selectable time ranges, from 0.05 s to 100 h, for the adjustment of the pulse time 2 Potentiometer with direct reading scale for the fine

More information

Pressure switch RE B/ Type HEDE10.../1/ Operating instructions

Pressure switch RE B/ Type HEDE10.../1/ Operating instructions Pressure switch Type HEDE10.../1/ RE 30276-B/10.10 Replaces: 06.10 Operating instructions 2/20 Bosch Rexroth AG HEDE10.../1/ RE 30276-B/10.10 Contents 1 Overview of menu...3 2 Safety note... 4 3 Operating

More information

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300 Monitoring Technique VARIMETER PRO Multifunction Measuring Relay MK 93N, MH 93 268581 Product description MK 93N MH 93 The universal measuring relays MK 93N / MH 93 of the VARIMETER PRO series monitor

More information

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet CDC 51 1 F000 1 7 6 5 8 Characteristics Single-function impulse-off timer One device includes 10 time ranges, from 0.05 s to 00 h, for the adjustment of the pulse time c/o contacts nd c/o contact can be

More information

APPLICATIONS. Furnaces and ovens Burners and boilers Weighing and batching Process control Plastics processing... DESCRIPTION

APPLICATIONS. Furnaces and ovens Burners and boilers Weighing and batching Process control Plastics processing... DESCRIPTION Digital 280-1 Digital Indicator BluePort Front interface and BlueControl Software Maintenance manager and error list Large 5-digit display Limit values with hysteresis, time gate and gradient ON/OFF and

More information

Modular Panel Meter Series EDM 35

Modular Panel Meter Series EDM 35 Modular Panel Meter Series EDM 35 CONTENTS Page 1. Introduction 2 1.1 Getting Started 2 1.2 Overall Description 3 1.3 Features 3 1.4 Block Schematic 4 2. Unit Description 4 2.1 Modules 4 2.2 Main Unit

More information

70 SERIES. Line monitoring relay

70 SERIES. Line monitoring relay 70 SRIS 70 SRIS lectronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window Mode, Phase

More information

Process Indicator PA308

Process Indicator PA308 GmbH ostal address:: House address Fon () 0 00 ostfach Löhestr. Fax () 0 00 http: // www.tematec.de Hennef Hennef email: team@ tematec.de Data heet A0 age / rocess Indicator A0 Digital Indicator, microprocessorcontrolled,

More information

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Linearized RTD Input 5B34 FEATURES Amplifies, Protects, Filters, and Isolates Analog Input. Linearize a wide variety of 2 & 3 wire RTDs. (True 4-wire RTD measurements are provided by the 5B35).

More information

DINALOG A 96 x 24. Programmable quasi-analogue bar graph meters. Technical characteristics DINALOG A 96 x 24

DINALOG A 96 x 24. Programmable quasi-analogue bar graph meters. Technical characteristics DINALOG A 96 x 24 Bar graph displays For process control, automation, and laboratory applications Current, voltage, resistance, frequency and temperature Up to 0.5% resolution DINALOG A 96 x 24 Programmable quasi-analogue

More information

Electronic timer CT-AHD.22

Electronic timer CT-AHD.22 2CDC 251 093 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied

More information

Cube67 - Modular I/O station

Cube67 - Modular I/O station Compact modules Cube67 DI16 C 8xM12 Cube67 DI8 C 4xM12 Cube67 DI8 C 8xM8 Digital inputs Art.-No. UL 56602 UL 56612 UL 56622 approx. 50 ma approx. ma Terminator integrated Configuration PIN 2 input/diagnostic

More information

English. Operating manual. Limit switch GS125. Keep for future reference. Ventures / brands of GHM

English. Operating manual. Limit switch GS125.  Keep for future reference. Ventures / brands of GHM English Operating manual Limit switch GS125 Ventures / brands of GHM www.ghm-messtechnik.de Keep for future reference. Table of contents Page 1. Intended use (areas of application)... 3 1.1 Safety signs

More information

preliminary ISOMETER isoev425 with coupling device AGH420 Preliminary datasheet

preliminary ISOMETER isoev425 with coupling device AGH420 Preliminary datasheet with coupling device GH420 Insulation monitoring device for unearthed DC circuits (IT systems) for charging electric vehicles Preliminary edition Preliminary datasheet TD106038en /.2012 with coupling device

More information

Voltage supply. AC 110 to 240 V +10/-15 %, 48 to 63 Hz AC/DC 20 to 30 V, 48 to 63 Hz. Interfaces

Voltage supply. AC 110 to 240 V +10/-15 %, 48 to 63 Hz AC/DC 20 to 30 V, 48 to 63 Hz. Interfaces DATAVU 6 Datasheet The DataVU 6 paperless recorder features a resistive touchscreen and an intuitive, icon-based operation and visualization concept that makes it very easy to use. There are different

More information

APPLICATION. Data acquisition Remote I/O I/O extension DESCRIPTION CONSTRUCTION

APPLICATION. Data acquisition Remote I/O I/O extension DESCRIPTION CONSTRUCTION RM 200 Modular I/O system open MODBUS Ethernet Plug-in I/O modules Suitable for CANopen/PROFIBUS-DP/MODBUS/Ethernet Modules for numerous sensors and signals 2, 4 or 8 channels, depending on module version

More information

TECHNICAL DATA SHEET. ProVU 4 Advanced Temperature Controller. Features. Description

TECHNICAL DATA SHEET. ProVU 4 Advanced Temperature Controller. Features. Description ProVU 4 Advanced Temperature Controller ¼ DIN Format Graphical / text LCD Display (red/green) Profiling option Datalogging option (data, alarms & events) 5 language (English, French, German, Italian, Spanish)

More information

Ecograph T. Technical Information. Multi Channel Recorder Display, record, communicate

Ecograph T. Technical Information. Multi Channel Recorder Display, record, communicate Technical Information Multi Channel Recorder Display, record, communicate Applications The instrument can be used in many processes and industries: Quality and quantity monitoring in the water/ wastewater

More information

GIR 230 TC Version 1.1

GIR 230 TC Version 1.1 E33.0.12.6C-02 Manual for connection and operation of the GIR 230 TC Page 1 of 14 Manual for connection and operation of GIR 230 TC Version 1.1 E33.0.12.6C-02 Manual for connection and operation of the

More information

SSR - Supplies - Relays

SSR - Supplies - Relays GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 SSR - Supplies - Relays System Solid State Relays from 25 up to 125 A Relay

More information

TM3TI4 module TM3-4 inputs temperature

TM3TI4 module TM3-4 inputs temperature Characteristics module TM3-4 inputs temperature Complementary Analogue input resolution Permissible continuous overload Input impedance LSB value Conversion time Sampling duration Main Range of product

More information

Printing recorder with text printing and 24-character LED dot-matrix display. Brief description. Overview of functions. Features

Printing recorder with text printing and 24-character LED dot-matrix display. Brief description. Overview of functions. Features JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F Approvals a culus f CCC CT-BS Circuit diagram Marker label Marks g c CE C-Tick Order data

More information

02/11/2015

02/11/2015 35 mm - 1 Relay 8A OUR1 Part number 88867105 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external

More information

Indicomp 4 Bargraph Indicator

Indicomp 4 Bargraph Indicator Data Sheet 10/30-2.16-EN Indicomp 4 Bargraph Indicator Display is optionally LCD active: self-luminuous green on black self-luminuous green on blue LCD passive: self-luminuous black on light grey 2 input

More information

Thermocouples Resistance thermometer Resistance transmitter Potentiometer Voltage Current. for floating contacts or PLC level Functions:

Thermocouples Resistance thermometer Resistance transmitter Potentiometer Voltage Current. for floating contacts or PLC level Functions: M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA Continous voltage monitoring Mains fluctuation detection Detects voltage drop / short interruptions of at least 10ms Prevents undefined states in switching and control systems Generates reset pulse after

More information

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS I-7520 RS-232 to RS-485 Converter I-7510 RS-485 Repeater RS-232 RS-485 I-7000 SERIES Common Specifications Isolation voltage: 3000VDC Speed: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115000 Dual watchdog

More information

UNIVERSAL TRANSDUCER AR594

UNIVERSAL TRANSDUCER AR594 APAR - SALES OFFICE 05-090 Raszyn, ul. Gałczyńskiego 6, Poland Tel. +48 22 101-27-31, +48 22 853-49-30 E-mail: automatyka@apar.pl Website: www.apar.pl USER INSTRUCTION UNIVERSAL TRANSDUCER AR594 Version

More information

Three-phase monitoring relay

Three-phase monitoring relay 2CDC 251 044 F0t08 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet 2CDC 251 056 F0t07 Features Rated control supply voltage 24-48 V DC, 24-240 V AC Single-function ON-delay timer One device includes 10 time ranges (0.05 s - 300 h) 1 c/o contact 2 LEDs for status indication

More information