VFS 2 Video Fiber Scope User s Guide. Test & Inspection

Size: px
Start display at page:

Download "VFS 2 Video Fiber Scope User s Guide. Test & Inspection"

Transcription

1 VFS 2 Video Fiber Scope User s Guide Test & Inspection

2

3 VFS 2 Video Fiber Scope User s Guide Test & Inspection , AFL Telecommunications, all rights reserved. VFS Revision B Specifications are subject to change without notice.

4 Limited Warranty One Year Limited Warranty All Noyes products are warranted against defective material and workmanship for a period of one year from the date of shipment to the original customer. Any product found to be defective within the warranty period will be repaired or replaced by Noyes. In no case will Noyes liabilities exceed the original purchase price of the product. Exclusions The warranty on your equipment shall not apply to defects resulting from the following: Unauthorized repair or modification Misuse, negligence, or accident CE Information These instruments have been designed and tested to comply with the relevant sections of any applicable specifications including full compliance with all essential requirements of all applicable EU Directives. Returning Equipment To return equipment, please contact Noyes to obtain additional information and a Service Request (S.R.) number. To allow us to serve you more efficiently, please include a brief description specifying the reason(s) for the return of the equipment. AFL Telecommunications Noyes 16 Eastgate Park Road Belmont, NH Phone: Fax:

5 Contents Safety Information... iii Section 1: General Information Contacting Noyes Customer Service... 1 Unpacking and Inspection... 1 Feature Overview... 2 Required Accessories... 3 Section 2: Functional Description VFS 2 Inspection Probe... 4 VFS 2 Display Unit... 6 VCP 1 Video Capture Port... 8 Section 3: Operating Instructions Installing Adapter Tips VFS 2 Adapter Tips Using Adapter tips with blue Delrin end piece Using the VFS 2 universal cap adapter Connecting the VFS 2 Probe to a Display or VCP 1 unit Focusing Inspecting Connectors with Probe and Display i

6 Transferring images to a PC Inspecting Connectors with Probe and VCP 1 Unit Examples of Fiber Images Section 4: General Care and Maintenance General Care Lens Care To inspect the lens To clean the lens Charging the VFS 2 Display Battery Section 5: Specifications Optical Specifications VFS 2 Probe Specifications VFS 2 Display Specifications VCP 1 Video Capture Port Specifications ii

7 Safety Information!!!! WARNING! Use only the specified AC adapter. Use of another type of AC adapter can damage the instrument and create the danger of fire and electrical shock. WARNING! To avoid the danger of fire and electrical shock: Never use a voltage that is different from that for which the AC adapter is rated. Do not plug the unit into a power outlet that is shared by other devices. Never modify the power cord or excessively bend, twist, or pull it. Do not allow the power cord to become damaged. Do not place heavy objects on the power cord or expose it to heat. Never touch the AC adapter while your hands are wet. Should the power cord become seriously damaged (internal wiring exposed or shorted), contact the manufacturer to request servicing. CAUTION! To avoid serious eye injury, never look directly into optical outputs of fiber optic network equipment, test equipment, patch cords, or test jumpers. Always assume that optical outputs are on. CAUTION! The VFS 2 should be protected from accidental drops at all times. A drop on the tip end of the probe can cause damage which would prevent use of the probe. Drops iii

8 in other areas can lead to misalignment or damage as well. If the fiber end-face image appears to be distorted or is off the display screen, the unit should be returned to the factory for repair and/or calibration.! NOTICE! The VFS 2 Probe, VFS 2 Display, and VCP 1 Video Capture Port contain no user-serviceable components inside. Except for changing batteries in the VFS 2 Display, these instruments must be returned to Noyes for repair. Opening instruments shall void the factory warranty. IMPORTANT! Although the VFS 2 Probe has been designed to operate in a wide range of environmental conditions, care should be taken when handling or storing any precision optical equipment such as the VFS 2 probe. iv

9 Section 1: General Information The purpose of this User s Guide is to explain how to use and maintain Noyes test equipment. Please check our web site at (click on Products > Noyes Test & Inspection) for updates to this manual, software updates, and additional application information. If you have any questions about your instruments and recommended accessories, or if you need technical or sales support, please contact Noyes Customer Service. Contacting Noyes Customer Service You may call Noyes Customer Service between 8 a.m. and 5 p.m., United States Eastern Time, as follows: Phone: Fax: Web: (click on Products > Noyes Test & Inspection) Unpacking and Inspection These instruments have been carefully packed in accordance with standard shipping procedures. Examine the equipment for damage that may have occurred during shipment. If you find any damage, please contact Noyes. 1

10 2 Feature Overview The VFS 2 is a small extremely versatile Video Fiber Scope designed for the inspection of fiber optic connectors and couplers. The VFS 2 retains the superior image quality associated with Noyes inspection products. The unique optical-knuckle allows the user to orient the VFS 2 Probe head in virtually any direction. This feature allows the user to view connectors that may be located in tight or difficult locations. With a Probe head length of less than 8 cm (3.25 ), access into crowded/ cramped quarters becomes a reality. The VFS 2 resolves ¾ micron scratches keeping with our standard of quality end-face images. This unit is designed for one-handed operation and with the optical-knuckle feature, the unit is equally easy for both right and left handed individuals. The new precision adapter tips for the VFS 2 Inspection Probe ease getting fiber images in the viewing area. These tips ensure the optics will view into the alignment sleeve, thus simplifying centering the fiber. An adapter tip must be left on the Probe at all times to protect the objective lens. The VFS 2 Inspection Probe may be paired with the VFS 2 high-resolution 3.5 (diagonal) Display or the VCP 1 Video Capture Port. The VFS 2 Display is a compact, portable unit that provide hours of continuous operation as well as rechargeable battery. The VCP 1 Video Capture Port allows the user to inspect fiber optic end-faces and capture viewed images on a PC. The VCP 1 simply attaches via a standard USB A plug connector to a computer and offers plug and play installation. With the supplied easy-to-use software, fiber end images can be saved and organized for analyzing, printing, and archiving.

11 To ensure proper operation, it is important to keep all optical connections and surfaces free from dirt, oils, or other contaminants. Proper cleaning techniques must be performed on fiber connectors, connector adapters, and optical ports. Refer to the section on maintenance for more information on cleaning methods. Always replace protective dust caps. Required Accessories The VFS 2 Inspection Probe requires an adapter tip that matches the connector type to be inspected. Adapter tips for all standard connector types are available. For an up-to-date list of adapter tips contact Noyes, or visit our web site at (click on Products > Noyes Test & Inspection > Accessories & Services). A supply of cotton tipped swabs (single or double ended) and commercial lens cleaner is recommended for cleaning the optical port on the Probe. Also, a can of filtered compressed air is useful for blowing contaminates out of connector adapter tips. For cleaning connector end-faces on test jumpers and in fiber frames or adapters, Noyes recommends using our exclusive FCC2 non-hazardous cleaning fluid and CCT molded cleaning tips. CCT cleaning tips and FCC2 cleaning fluid may be combined into FCP1 fiber optic cleaning kits. Noyes offers a complete selection of FCP1 cleaning kits for field cleaning. The FCP1 Series of kits delivers compact, safe, easy to use, reliable cleaning for all types of fiber optic connector end-faces. Visit our web at (click on Products > Noyes Test & Inspection > Cleaning Supplies) for more information. 3

12 Section 2: Functional Description 4 VFS 2 Inspection Probe The VFS 2 is a small extremely versatile video fiber scope with a Probe head length of less than 8 cm (3.25 ) specially designed for inspecting fiber oiptic terminations that may be located in tight or difficult locations. 1 Probe head - The VFS 2 rotating Probe head may be positioned to any angle. The full 360 degree rotation of the head allows unparalleled access to connectors and bulkhead adapters. 2 Lens tube - This tube contains the internal lens. Also, it accepts various precision adapter tips. 3 Optical port - This is the internal lens. 4 Adapter tip - The VFS 2 Probe requires an adapter tip that matches the connector type to be inspected. Select the appropriate adapter and mount it on the Lens tube, replacing the universal tip that should be kept on the VFS 2 Probe at all other times for protection. The precision adapter tips for the VFS 2 ease getting fiber images in the viewing area. These tips ensure the optics will view into the alignment sleeve, thus simplifying centering the fiber. 5 Focus wheel - Used for focusing adjustments. Turn slowly the knurled focus wheel until the fiber end-face image is viewed in sharp focus. If needed, reverse the rotation of the focus wheel and continue to focus until the best resolution and contrast of the displayed fiber end-

13 face image is achieved. 6 Modular RJ11 connector - Used to connect the VFS 2 Probe to the VFS 2 Display unit or Video Capture Port (VCP 1) Figure 2-1: VFS 2 Inspection Probe 5

14 VFS 2 Display Unit The VFS 2 Display unit is a portable high-resolution 3.5-inch video display designed to interface with the VFS 2 Probe. The VFS 2 Probe in conjunction with the VFS 2 Display allows inspecting fiber optic connectors without need of removing them from their bulkhead adapters. 1 VFS 2 Display unit screen (8.9 cm) diagonal color TFT-LCD display. Provides images equivalent to 250x magnification of fiber optic terminations being inspected with the VFS 2 Probe. 2 [Probe] port - The RJ11 jack provides power to and receives signal from the VFS 2 Inspection Probe. 3 [Video out] port - This port provides connection to an external monitor or to a PC via an interface cable. 4 Battery status indicators: - Identify battery conditions as follows: Red indicator [ON] - Low battery condition. Battery requires charging. Green indicator [BLINKING] - Battery is charging. Green indicator [ON] - Battery is fully charged. 5 [Power] port - This is the interface for the AC power adapter/charger. [Power] port provides AC power to the Display unit for operation and battery recharging. When an AC adapter/ charger is plugged in, the battery will be charged whether the power switch is ON or OFF. 6 [Power] switch - Turns the VFS 2 Display unit and VFS 2 Probe On or Off. 6

15 1 NOYES AFL Telecommunications VFS2 VIDEO FIBER SCOPE DISPLAY PROBE VIDEO OUT CHG / 18V Figure 2-2: VFS 2 Video Display (front and bottom views) 7

16 VCP 1 Video Capture Port The VCP 1 Video Capture Port is an interfacing module that provides high-speed composite video signal to a digital format conversion for capturing and displaying video data on a PC. The VCP 1 simply attaches via a standard USB connector to your computer and offers plug and play installation. When used in conjunction with the VFS 2 Probe, the VCP 1 Video Capture Port allows the user to inspect fiber optic end-faces and capture viewed images on a computer. With the supplied easy-to-use software, fiber end images can be saved and organized for analyzing, printing, and archiving. For a complete description of the Video Capture software, refer to the User s Guide supplied with the software. 1 [Probe] port located on the top panel - [Probe] port - the RJ11 jack provides a video input for a composite video signal from the VFS 2 Probe. The VFS 2 modular connector (RJ11) to be plugged into the VCP 1 [Probe] port 2 [Active] indicator - The red LED will turn on when the video capture software (supplied with the VCP 1 unit) identifies the VCP 1 unit on the USB line. 3 [Snap shot] button - This is the video capture button for single shot video capture. Press this button to capture the displayed image. 4 USB A plug connector - Used to connect the VCP 1 to a PC. 8

17 VFS 2 modular connector - RJ Active 2 Snap Shot VCP1 VIDEO CAPTURE PORT NOYES AFL Telecommunications 4 Figure 2-3: VCP 1 Video Capture Port 9

18 Section 3: Operating Instructions This section describes the operation of the VFS 2 Probe and Display or VCP 1 unit for inspecting installed fiber optic connectors. Installing Adapter Tips Figure 3-1 illustrates the following procedures. 1 Select the appropriate adapter tip that matches the connector type to be inspected. 2 Before installing the selected adapter tip, remove the universal adapter tip supplied with the VFS 2 Inspection Probe (or any other installed tip). Note: In order to distinguish an adapter tip from the internal lens tube, each tip has a knurled (grooved) finger grip area near the base. 3 To unscrew the installed adapter tip from the end of the VFS 2 Probe, twist it with a counterclockwise motion as viewed from the adapter tip end. 4 Gently slip the adapter tip off the end of the internal lens tube and return it to the provided storage container. 5 Be sure that the lens tube is retracted fully by turning the focus wheel counterclockwise as viewed from the tip end. 6 Gently slide the adapter tip to be installed over the lens tube being careful not to contact the 10

19 small lens opening. 7 Twist the adapter tip clockwise in order to screw it into the end of the VFS 2 Probe (FINGER TIGHT ONLY!). Adapter tip Internal lens tube Focus wheel Knurled area Tip base Lens opening Figure 3-1: Adapter tip installation 11

20 12 VFS 2 Adapter Tips Using Adapter tips with blue Delrin end piece Adapter tips, which have a definite orientation such as the ASC shown in the illustration below, may have the blue end piece, which may be rotated to a convenient position. To rotate the blue end piece: 1 Insert the blue end piece into the connector being inspected. 2 Hold the VFS 2 Probe and the black [base] portion of the adapter tip in one hand. 3 Hold the blue end piece and connector being inspected in the other hand. 4 The Probe and the [base] may now be rotated as one unit while the blue end piece is prevented from rotating. Example: It may be convenient to have the Probe body pointed downward when inserted into a connector patch panel. Re-adjust as needed for different situations. Note: The blue end-piece should not be removed from the adapter tip. When removing the adapter tip from the VFS 2 Probe, be sure to unscrew the black [base] as usual. Blue end piece [Base] portion of the Adapter tip Hold the Probe and the [base] in one hand

21 Using the VFS 2 universal cap adapter The VFS 2 universal cap adapter provides expanded options for inspection a wide variety of connector types. It must be handled with additional care beyond that given to the standard VFS 2 due to mechanical considerations. Please follow the instructions below when installing the universal cap adapter to the VFS 2 Probe and also when attaching each Noyes adapter cap to the universal cap adapter. 1 Thread the universal cap adapter into the VFS 2 Probe, and then tighten it using the knurled area at the Probe end (FINGER TIGHT ONLY!). 2 When attaching a Noyes adapter cap to the universal cap adapter, hold the straight section of the universal cap adapter firmly as each Noyes adapter cap is gently screwed onto the end. 3 Once installed, each Noyes adapter cap can be panned in any X-Y direction as follows: Gently twist the engraved lock ring toward the unlock direction until it is only lightly snugged down. As needed, move the installed Noyes adapter cap to center either the fiber end or to inspect adjacent areas of the ferrule. If desired, the lock ring can then be gently turned in the lock direction to hold the position. 4 Removal of a Noyes adapter cap or the universal cap adapter itself is the reverse of the directions provided above. Note: Use caution not to rotate the probe head against the probe body while the universal cap adapter is attached. 13

22 Connecting the VFS 2 Probe to a Display or VCP 1 unit 1 Plug the modular connector (RJ11) at the end of the VFS 2 coiled cord into the mating RJ11 jack - Probe port on the Display or VCP 1 unit. 2 Note the orientation of the VFS 2 modular connector as there is a tab that must be aligned on the connector and mating RJ11 jack. 3 To unplug the VFS 2 Probe, gently squeeze the tab on the modular connector and pull it straight out from the mating RJ11 jack - Probe port. mating RJ11 jack on the Display or VCP 1 unit modular connector at the end of the VFS 2 Probe coiled cord tab 14 Figure 3-2: Connecting the VFS 2 Probe to a Display or VCP 1 unit.

23 Focusing 1 The fiber end-face image is brought into sharp focus by turning the knurled, silver focus wheel located in the probe head. 2 At some point, you may see an image of the light source used in the scope. Continue turning the focus wheel slowly until the fiber end-face is viewed in sharp focus. 3 Reverse direction if the focus wheel reaches the end of its range without obtaining an image. Note: A good method for achieving optimum focus is to approach the best focus from one direction of motion of the focus wheel. Also, be sure that the VFS 2 Probe tip is fully inserted into the connector under inspection, or that the connector ferrule is fully inserted into the tip for universal tips or other tip styles. focus wheel probe head. Figure 3-3: Focusing 15

24 Inspecting Connectors with Probe and Display 1 Select the appropriate adapter tip that matches the connector to be inspected. 2 Place the selected adapter tip on the internal lens tube. 3 Plug the VFS 2 Probe cord into the probe port on the Display unit. 4 Insert the adapter tip into the connector to be inspected. If needed, the Probe head rotates to inspect those hard to reach connectors. 5 To bring the fiber end-face image into view, turn the focus wheel slowly until the fiber end-face is viewed in sharp focus. 6 If you are unable to bring the image into focus, check that the adapter tip is screwed on tightly, then try again (FINGER TIGHT ONLY!). Transferring images to a PC Depending upon the application, it may be desirable to produce documentation of the inspected connectors. The VFS 2 Display unit allows transferring of the displayed image to a computer. This process requires a video cable and a computer that is equipped with an external or internal video digitizer capable of handling NTSC signal. To send the video signal from the VFS 2 Display unit to a computer: 1 Plug one end of the video cable into the Video Out port on the VFS 2 Display and the other end into the Video In port on the digitizer. 16

25 2 Insert the VFS 2 Probe into the connector to be inspected. If needed, the Probe head rotates to inspect those hard to reach connectors. 3 To bring the fiber end-face into view, turn the focus wheel slowly until the fiber end-face is viewed in sharp focus. 4 If you are unable to bring the image into focus, check that the adapter tip is screwed on tightly, then try again (FINGER TIGHT ONLY!). 5 The VFS 2 Display Unit is now rerouting the video signal to the digitizer. Refer to the digitizer's user's guide for additional information on capturing, saving, and printing the displayed connector image. 17

26 Inspecting Connectors with Probe and VCP 1 Unit 1 From the supplied CD-ROM, install the driver and Video Capture software to your computer. Note: For a complete description of the Video Capture software, refer to the User s Guide supplied with the software. 2 With the Video Capture software installed, plug the VCP 1 Video Capture Port into the USB port. 3 With the VCP 1 connected to the USB port, plug the VFS 2 Probe into the RJ11 jack - Probe port on the VCP 1. 4 Open the Video Capture software and select acquire image. 5 The red LED - [Active] indicator on the VCP 1 will turn on when the software identifies the VCP 1 unit on the USB line. 6 Insert the VFS 2 Probe into the connector to be inspected. 7 Observe the fiber image on the screen and focus the image by rotating the focus wheel on the VFS 2 Probe. 8 To capture the displayed image press the [Snap shot] button on the VCP 1 or click on the [Capture] button on the screen. 18

27 Examples of Fiber Images Various examples of fiber end-face images ranging from excellent to very poor conditions. Excellent condition Uncleaned, lint or dust Scratches and dirt Severely scratched face Cleaning residue, water or alcohol 19

28 Section 4: General Care and Maintenance 20 General Care The VFS 2 Inspection Probe is a precision optical device. As such, there are certain parts of the Probe that cannot be protected from abuse due to the small geometry required to interface with modern fiber optic connectors. The VFS 2 should be protected from accidental drops at all times. A drop on the tip end of the Inspection Probe can cause damage, which would prevent use of the Probe. Drops in other areas can lead to misalignment or damage as well. If the fiber end-face image appears to be distorted or is off the display screen, the unit should be returned to the factory for repair and/or calibration. Lens Care Contact with the small lens at the end of the Probe lens tube should be avoided. Adapter tips should be installed by gently sliding over the end of the lens tube as mentioned earlier. This action will not harm the lens. If the face of the small lens becomes contaminated, the image quality will be degraded. The lens must be kept free from dirt or other contaminants. It should be cleaned as needed using the instructions on the following page.! CAUTION! Remove Probe power for the following procedures.

29 To inspect the lens 1 Hold the VFS 2 Probe at an angle to room lighting. 2 Examine the lens with a magnifying glass. 3 If the lens surface does not appear to be clean and free of fingerprints, dust, or other contaminants, it should be cleaned. To clean the lens To access the lens, first remove the adapter tip that may be installed. Lens removal is not recommended. 1 To remove the installed adapter tip, twist it with a counterclockwise motion as viewed from the adapter tip end. 2 Gently slip the adapter tip off the end of the internal lens tube. 3 Using a double ended cotton swab (such as a Q-tip) or two single ended swabs, apply a single drop of lens cleaner to one end of a swab. Touch it to the lens, apply gentle pressure and rotate gently several times. 4 Immediately, use the dry end of a swab to repeat the action. This cleans the lens and removes remaining moisture. 5 Using a can of filtered compressed air (held vertically), blow out any contaminants from the adapter tip 6 Once completed, replace the adapter tip over the internal lens tube being careful not to contact the small lens opening. Twist the adapter tip clockwise in order to screw it into the end of the VFS 2 Probe. Finger tighten only! 21

30 Charging the VFS 2 Display Battery When the Low Battery indicator illuminates RED, the internal battery requires recharging. To recharge the internal battery, connect the AC power adapter/charger to the AC adapter/charger port and a wall outlet. The battery will charge in 4 hours. PROBE VIDEO OUT CHG / 18V Battery status indicators: Low Battery indicator Red LED ON - low battery condition; battery requires charging. AC adapter/charger port Provides AC power to the Display unit for operation and battery recharging. Green LED BLINKING - battery is charging. Green LED ON - battery is fully charged. 22 Figure 4-1: Charging the VFS 2 display battery.

31 Section 5: Specifications Optical Specifications Field of view Magnification Resolution Video output VFS 2 Probe Specifications Operating temperature Storage temperature Humidity Probe weight Probe body size (L x W x D) Probe head size (with FC adapter), (L x W x D) 500 microns diagonal (300 microns vertical, 400 microns horizontal) 180x on 3.5 display ¾ micron scratch NTSC 0 to +50 C -20 to +60 C 0 to 90% (non-condensing) 0.4 lb (0.2 kg) 6.3 x 1.3 x 1.3 in (15.9 x 3.3 x 3.3 cm) 3.1 x 1.0 x 0.6 in (7.9 x 2.5 x 1.5 cm) Specifications are subject to change without notice. 23

32 VFS 2 Display Specifications Display screen size Display package with protective boot size Weight Power Battery life with VFS 2 probe Operating temperature Storage temperature Humidity Li-Ion battery pack charging temperature Li-Ion battery pack recharging time AC Power Adapter 3.5 inch TFT NTSC 9.0 x 2.0 x 4.7 in (22.9 x 5.1 x 11.9 cm) 2 lb (0.9 kg) Li-Ion battery pack or AC adapter > 4 hours 0 to 50 C -20 to +60 C 0 to 90% RH non-condensing -10 to +45 C 4 hours AC Input :100 to 240 V, Hz, 1A DC Output : 18 V, 2.5 A Specifications are subject to change without notice. 24

33 VCP 1 Video Capture Port Specifications Interface type Operating system Video input Output Analog video format Video capture resolution Snap shot Video capture format(s): Power source USB data bandwidth Weight Size (L x W x D) USB Windows 98 / 98SE / ME / 2000 / XP Noyes RJ11 connector USB Standard (VCP 1 is a Twain compatible device using supplied software) NTSC or PAL 640 x 480 pixels Single button to capture still images at 640 x 480 pixels JPEG ma (max) through USB port to 6 foot cord 4Mbps - 8Mbps isochronous 0.25 lb (0.11 kg) 4.0 x 2.2 x 1.0 in (10.2 x 5.6 x 2.5 cm) Specifications are subject to change without notice. 25

34

35 Thank you for choosing Noyes Test & Inspection 16 Eastgate Park Road Belmont, NH Phone: Fax: NOYES ISO 9001 CERTIFIED Test & Inspection

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide 2004-2009, AFL Telecommunications, all rights reserved. COM4-00-1001 Revision E, 2009-06-16 Specifications

More information

OFS 300 Optical Fiber Scope User s Guide

OFS 300 Optical Fiber Scope User s Guide T e s t & I n s p e c t i o n OFS 300 Optical Fiber Scope User s Guide OFS 300 Optical Fiber Scope User s Guide T e s t & I n s p e c t i o n 2002, AFL Telecommunications, all rights reserved. OFS1-00-1000

More information

CSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide

CSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide CSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide www.aflglobal.com or (800) 321-5298, (603) 528-7780 Limited Warranty All NOYES test equipment products

More information

FOCIS Flex - No Wireless Fiber Optic Connector Inspection System User Guide

FOCIS Flex - No Wireless Fiber Optic Connector Inspection System User Guide Test & Inspection FOCIS Flex - No Wireless Fiber Optic Connector Inspection System User Guide www.aflglobal.com or (800) 321-5298, (603) 528-7780 Table of Contents Safety Information....3 How to View Device

More information

VIS Video Inspection Scope

VIS Video Inspection Scope User s Guide VIS 300 - Video Inspection Scope VIS1-00-2000, Rev A, 6-09-10 Specifications subject to change without notice Contents Section 1 - General Overview A. Contact ODM for customer service B. Unpacking

More information

GVIS Video Inspection Scope

GVIS Video Inspection Scope User s Guide GVIS 300 - Video Inspection Scope GVIS1-00-2000, Rev A, 6-09-20 Specifications subject to change without notice Contents Section 1 - General Overview A. Contact Tempo for customer service

More information

VPC-64/ VPX-64 VIDEO POLE CAMERA OPERATION MANUAL

VPC-64/ VPX-64 VIDEO POLE CAMERA OPERATION MANUAL VPC-64/ VPX-64 VIDEO POLE CAMERA OPERATION MANUAL RESEARCH ELECTRONICS INTERNATIONAL 455 Security Drive Algood, TN 38506 U.S.A. +1 931-537-6032 http://www.reiusa.net/ COPYRIGHT RESEARCH ELECTRONICS INTERNATIONAL

More information

Fiber Optic Prism Switch USER S MANUAL

Fiber Optic Prism Switch USER S MANUAL Fiber Optic Prism Switch USER S MANUAL Warranty Newport Corporation warrants this product to be free from defects in material and workmanship for a period of one year from the date of shipment. If found

More information

Copyright Black Box Corporation. All rights reserved.

Copyright Black Box Corporation. All rights reserved. Copyright 1999. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax 724-746-0746 JUNE 1999 FT990A FT991 FT992 FT993 Fiber Optic Inspection Scope CUSTOMER

More information

OLS Series Light Sources, OPM Series Optical Power Meters, and Optical Loss Test Kits Quick Reference Guide

OLS Series Light Sources, OPM Series Optical Power Meters, and Optical Loss Test Kits Quick Reference Guide OLS Series Light Sources, OPM Series Optical Power Meters, and Optical Loss Test Kits Quick Reference Guide Warranty All NOYES test equipment products are warranted for a period of (1) one year from the

More information

OPERATION MANUAL SERIES BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085

OPERATION MANUAL SERIES BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085 OPERATION MANUAL SERIES 123000 BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA 01086 33 Airport Road, Westfield, MA 01085 Tel: (413) 562-3606 Fax: (413) 568-9809 Email: iti@scopes.com www.scopes.com

More information

User's Guide Video Borescope Model BR200

User's Guide Video Borescope Model BR200 User's Guide Video Borescope Model BR200 Introduction Congratulations on your purchase of this Extech BR200 Video Borescope. This instrument was designed for use as a remote inspection device. It can be

More information

OPERATION MANUAL SERIES MICRO BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085

OPERATION MANUAL SERIES MICRO BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085 OPERATION MANUAL SERIES 124000 MICRO BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA 01086 33 Airport Road, Westfield, MA 01085 Tel: (413) 562-3606 Fax: (413) 568-9809 Email: iti@scopes.com

More information

CONTENDER LED FRESNEL SPOT FOCUSING LIGHT USER MANUAL

CONTENDER LED FRESNEL SPOT FOCUSING LIGHT USER MANUAL CONTENDER LED FRESNEL SPOT FOCUSING LIGHT USER MANUAL Contender INTRODUCTION THANK YOU FOR CHOOSING GENARAY The Genaray Contender is a compact and versatile light that s ideal for still and tabletop photography,

More information

AirPro Surveyor 2 Manual

AirPro Surveyor 2 Manual AirPro Surveyor 2 Manual AirPro Surveyor Specifications Table of Contents Size 3/8 x 7 1/2 x 4 3/8 Weight 4.6 lbs. 2094 g Dynamic Range 1-1000 ml/min. total flow/constant flow Flow Capacity (8 Hrs.) 1000

More information

User Guide. Video Borescope. Models BR200 and BR250

User Guide. Video Borescope. Models BR200 and BR250 User Guide Video Borescope Models BR200 and BR250 Introduction Congratulations on your purchase of this Extech BR200 (17mm camera head) or BR250 (9mm camera head) Video Borescope. This instrument was designed

More information

Richter Optica. Instructions for Model: S-2 Dual Power Stereo Microscope

Richter Optica. Instructions for Model: S-2 Dual Power Stereo Microscope Richter Optica 6122 Innovation Way Carlsbad, California 92009 (800) 942-0528 US TOLL FREE (760) 438-0528 INTERNATIONAL Instructions for Model: S-2 Dual Power Stereo Microscope Eyepieces Post Diopter Adjustment

More information

M200 Handheld OTDR User s Guide

M200 Handheld OTDR User s Guide WWW.EXFIBER.COM M200 Handheld OTDR User s Guide Test & Inspection Limited Warranty One Year Limited Warranty All Noyes products are warranted against defective material and workmanship for a period of

More information

ViewConn Pro VC-8200

ViewConn Pro VC-8200 ViewConn Pro VC-8200 1. Introducing ViewConn 2. Using ViewConn Pro 3. Optional Integrated Optical Power Meter 4. Specifications Safety Fiber optic lasers use light wavelengths not visible to the human

More information

Video Borescope Inspection Camera

Video Borescope Inspection Camera Owner's Manual Video Borescope Inspection Camera Model 82027 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance

More information

User's Guide. Video Borescope. Model BR100

User's Guide. Video Borescope. Model BR100 User's Guide Video Borescope Model BR100 Introduction Congratulations on your purchase of this Extech BR100 Video Borescope. This instrument was designed for use as an inspection device. It can be used

More information

User's Guide. Video Borescope. Models BR200 and BR250

User's Guide. Video Borescope. Models BR200 and BR250 User's Guide Video Borescope Models BR200 and BR250 Introduction Congratulations on your purchase of this Extech BR200 (17mm camera head) or BR250 (9mm camera head) Video Borescope. This instrument was

More information

User Guide. HAWKEYE CLASSIC VIDEO BORESCOPES (Non-Articulating) Hawkeye Classic Video Borescope. Hawkeye Classic Video Borescope - Set Up

User Guide. HAWKEYE CLASSIC VIDEO BORESCOPES (Non-Articulating) Hawkeye Classic Video Borescope. Hawkeye Classic Video Borescope - Set Up User Guide Hawkeye Classic Video Borescope HAWKEYE CLASSIC VIDEO BORESCOPES (Non-Articulating) Table of Contents Set Up... Page 2 Operation.. Page 4 Troubleshooting Page 12 Specifications. Page 13 Hawkeye

More information

3M Duplex Polishing Machine 6851-E with Universal Dual Holder Instructions

3M Duplex Polishing Machine 6851-E with Universal Dual Holder Instructions 3M Duplex Polishing Machine 6851-E with Universal Dual Holder Instructions Safety Information Read, understand and follow all safety information contained in these user instructions prior to use of the

More information

Richter Optica. Instructions for: S6-BL, S6-TS, S6-SPS, S6-ILST Models

Richter Optica. Instructions for: S6-BL, S6-TS, S6-SPS, S6-ILST Models Richter Optica info@richter-optica.com Instructions for: S6-BL, S6-TS, S6-SPS, S6-ILST Models Trinocular port for c-mount adapter Zoom Knob Focusing Holder Clamp Diopter adjustable eyepieces Magnification

More information

Medimaging Integrated Solution Inc.

Medimaging Integrated Solution Inc. Medimaging Integrated Solution Inc. (MiiS) 1F, No. 7, R&D Rd II, Hsinchu Science Park, Hsinchu, TAIWAN 30076, R.O.C Issued date: Jan. 30, 2012 1 of 20 TABLE OF CONTENTS 1. Category 2. Symbols 3. Warnings

More information

FOCIS Flex Fiber Optic Connector Inspection System User Guide

FOCIS Flex Fiber Optic Connector Inspection System User Guide Test & Inspection FOCIS Flex Fiber Optic Connector Inspection System User Guide www.aflglobal.com or (800) 321-5298, (603) 528-7780 Table of Contents Safety Information....4 General Information...5 FOCIS

More information

PM-100 SERIES. Operation Guide. Power Meter V

PM-100 SERIES. Operation Guide. Power Meter V PM-100 SERIES Power Meter Operation Guide V5.27.16 Contents 1 Introduction...2 2 Warranty...2 3 Safety Information...3 4 Preparing for Operation...3 4.1 Unpacking the instrument...3 4.2 Discharged batteries...3

More information

OFL 200 Single-mode Optical Time Domain Reflectometer User s Guide

OFL 200 Single-mode Optical Time Domain Reflectometer User s Guide OFL 200 Single-mode Optical Time Domain Reflectometer User s Guide T e s t & I n s p e c t i o n OFL 200 Single-mode Optical Time Domain Reflectometer User s Guide T e s t & I n s p e c t i o n 2004-2007,

More information

TM-SERIES TABLE MOUNTING BRACKETS USER S GUIDE

TM-SERIES TABLE MOUNTING BRACKETS USER S GUIDE MODEL TM1278 FOR THE UNITED STATES SHOWN ABOVE MANUAL PART NUMBER: 400-0061-003 PRODUCT REVISION: 0 TM-SERIES TABLE USER S GUIDE INTRODUCTION TABLE OF CONTENTS Thank you for purchasing the TM-Series Mounting

More information

I-CAM PLUS USER MANUAL

I-CAM PLUS USER MANUAL I-CAM PLUS USER MANUAL 1. I-CAM PLUS Intraoral Camera 1.1 Features The I-CAM PLUS Intraoral Camera provides live video display, freeze, and capture capabilities for dental imaging. Displays live video

More information

HCC-CW-201A. CWDM Analyzer. Operation Guide

HCC-CW-201A. CWDM Analyzer. Operation Guide CWDM Analyzer Operation Guide Table of Contents Description... 3 Features... 3 Specifications... 4 Safety Information... 5 Preparing for Operation... 6 Unpacking the instrument... 6 Front keys definition...

More information

Handheld Video Microscope

Handheld Video Microscope Handheld Video Microscope SAFETY SUMMARY Personnel concerned with the operation of this instrument must thoroughly understand and follow the safety guidelines below. The manufacturer assumes no liability

More information

User Guide. Control Box. RoscoLED TM.

User Guide. Control Box. RoscoLED TM. RoscoLED TM Control Box User Guide This guide applies to the following RoscoLED Control Box models: RoscoLED Control Box 300W/Static White (293 22250 0000) RoscoLED Control Box 400W/VariWhite (293 22260

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

INSPECTION TOOL. Inspection Video Camera with Color LCD Monitor. EU Environmental Protection. Model: 8802LE,8803LE. Model: 8802LE,8803LE

INSPECTION TOOL. Inspection Video Camera with Color LCD Monitor. EU Environmental Protection. Model: 8802LE,8803LE. Model: 8802LE,8803LE INSPECTION TOOL Inspection Video Camera with Color LCD Monitor Model: 8802LE,8803LE EU Environmental Protection Waste electrical products should not be disposed of with household waste. Please recycle

More information

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR National Optical & Scientific Instruments Inc. 6508 Tri-County Parkway Schertz, Texas 78154 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR MODEL DC6-163 COMPOUND BIOLOGICAL MICROSCOPE WITH DIGITAL

More information

IPM Scope CAM ITEM # 2860CAM. Operation Manual

IPM Scope CAM ITEM # 2860CAM. Operation Manual IPM Scope CAM ITEM # 2860CAM Operation Manual Contents Overview 3 Keys and Indicators 4 Inserting the Battery 6 USB Connection 6 Device Setup 7 Getting the Best Image 8 Operation 9 Warranty 12 CE Declaration

More information

Fujitsu Stylistic ST4000 Series TABLET DOCK USER S GUIDE

Fujitsu Stylistic ST4000 Series TABLET DOCK USER S GUIDE Fujitsu Stylistic ST4000 Series TABLET DOCK USER S GUIDE DECLARATION OF CONFORMITY according to FCC Part 15 Responsible Party Name: Fujitsu PC Corporation Address: 5200 Patrick Henry Drive Santa Clara,

More information

User Manual. Trinocular Stereo Microscope

User Manual. Trinocular Stereo Microscope User Manual Trinocular Stereo Microscope Model V434 XV434 Series MicroscopeNet.com Table of Contents i. Caution.. 1 ii. Care and Maintenance... 2 1. Component Illustration... 3 2. Installation 4 3. Operation....6

More information

INSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE

INSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE INSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE TeleMatrix Copyright 2005 COMPLIANCE AND SAFETY As specified by FCC regulation, we are required to inform you of specific governmental

More information

User Manual. Rack Mount Display Monitor RMP-161-F17A. 6U 17.3 inch Rack Mount Display Monitor. Options : - AV, S-video input - Touchscreen

User Manual. Rack Mount Display Monitor RMP-161-F17A. 6U 17.3 inch Rack Mount Display Monitor. Options : - AV, S-video input - Touchscreen User Manual Rack Mount Display Monitor RMP-161-F17A 6U 17.3 inch Rack Mount Display Monitor Options : - AV, S-video input - Touchscreen Contents < Part. 1 > RMP-161-F17A 1.1 Package Content 1.2 Structure

More information

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR National Optical & Scientific Instruments Inc. 6508 Tri-County Parkway Schertz, Texas 78154 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR MODEL DC5-163 COMPOUND BIOLOGICAL MICROSCOPE WITH DIGITAL

More information

Start Here. All-in-One Printer. Print Copy Scan

Start Here. All-in-One Printer. Print Copy Scan Start Here All-in-One Printer Print Copy Scan Note: A USB 2.0 cable is required to connect your Kodak All-in-One printer to your Windows or Macintosh OS computer. Available in the Kodak online store or

More information

INSTRUCTIONS FOR MODEL C-1028 COMPOUND MICROSCOPE

INSTRUCTIONS FOR MODEL C-1028 COMPOUND MICROSCOPE INSTRUCTIONS FOR MODEL C-1028 COMPOUND MICROSCOPE Eyepiece (ocular lens) Eyepiece tube Head of microscope Objective turret (nosepiece) Arm Objective lens Stage Clips Condenser lens Stage Safety rack stop

More information

C-pan arm USERS INSTRUCTIONS

C-pan arm USERS INSTRUCTIONS C-pan arm USERS INSTRUCTIONS Designed 1 of 12 and made in Denmark Thanks for purchasing a 9.Solutions product. With great passion, we design our products to be as versatile as possible. We hope that our

More information

ACCU-SCOPE INC. 73 Mall Drive Commack, NY Phone: (631) Fax: (631)

ACCU-SCOPE INC. 73 Mall Drive Commack, NY Phone: (631) Fax: (631) 3065 ZOOM STEREO MICROSCOPE SERIES INSTRUCTIONS ACCU-SCOPE INC. 73 Mall Drive Commack, NY 11725 Phone: (631) 864-1000 Fax: (631) 543-8900 E-mail: info@accu-scope.com www.accu-scope.com Head Locking Screw

More information

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS SEE SAFETY WARNING ON PAGE 6 SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY IS DESIGNED TO BE USED WITH KBAC 3G SERIES DRIVES ONLY KBAC 3G SERIES MODELS CONTAIN THE "(3G)" DESIGNATOR ON THE PRODUCT LABEL

More information

ESV1018 Quantum Illuminator Cabinet INSTRUCTION MANUAL

ESV1018 Quantum Illuminator Cabinet INSTRUCTION MANUAL ESV1018 Quantum Illuminator Cabinet INSTRUCTION MANUAL Universal Power Supply EVS1018 Illuminated Cabinet Battery Pack: Optional Charts Charts HOTV Charts Letter Charts and Tumbling E More charts available

More information

DCS200/DCS200-09/DCS DCS300/DCS300-09/DCS355

DCS200/DCS200-09/DCS DCS300/DCS300-09/DCS355 THE SEEKER 200 SERIES & THE SEEKER 300 SERIES VIDEO INSPECTION SYSTEMS DCS200 (shown) DCS300 (shown) DCS200/DCS200-09/DCS200-05 DCS300/DCS300-09/DCS355 USER S MANUAL Please read this manual carefully and

More information

OMM200 and OMM200T. Metallurgical Microscope

OMM200 and OMM200T. Metallurgical Microscope OMM200 and OMM200T Metallurgical Microscope Instruction Manual (Please read the manual carefully before using the microscope) Contents Safety ----------------------------------------------------------------------------

More information

LED FOLDING WORKLIGHT TM

LED FOLDING WORKLIGHT TM LED FOLDING WORKLIGHT TM LED LIGHT POWERSTRIP USB CHARGING ITM. / ART. 689211 Model: LM55812 CARE & USE INSTRUCTIONS IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY For assistance with assembly

More information

SCT-MMA / SCT-SMA Fiber Optic Adapters

SCT-MMA / SCT-SMA Fiber Optic Adapters SCT-MMA / SCT-SMA Fiber Optic Adapters USER MANUAL ENGLISH i SAFETY WARNINGS Read First: Safety and Operational Information The international electrical symbols used on the instrument or in this manual

More information

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR National Optical & Scientific Instrument Inc. 6508 Tri-County Parkway Schertz, Texas 78154 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR MODEL DC4-156-S COMPOUND BIOLOGICAL MICROSCOPE WITH DIGITAL

More information

Maintenance station. For DePuy Synthes Power Tools Electric Pen Drive and Air Pen Drive Systems. instructions for use

Maintenance station. For DePuy Synthes Power Tools Electric Pen Drive and Air Pen Drive Systems. instructions for use Maintenance station For DePuy Synthes Power Tools Electric Pen Drive and Air Pen Drive Systems instructions for use Table of Contents introduction 2 operating instructions 3 Care and Maintenance 6 Troubleshooting

More information

TOUPCAM QUICK GUIDE INSTALLATION MANUAL

TOUPCAM QUICK GUIDE INSTALLATION MANUAL TOUPCAM QUICK GUIDE INSTALLATION MANUAL January 2013 1 WARNING! TO AVOID THE RISK OF FIREOR ELECTRICAL SHOCK. NEVER EXPOSE THIS PRODUCTTOWATEROR OPERATEIN AHIGH HUMIDITYENVIRONMENT. Keep camera away from

More information

TABLET DOCK USER S GUIDE

TABLET DOCK USER S GUIDE Fujitsu Stylistic ST Series Tablet PC TABLET DOCK USER S GUIDE Warning Handling the cord on this product will expose you to lead, a chemical known to the State of California to cause birth defects or other

More information

UMTI [UMTI USER MANUAL] User s Manual. Handheld Surveillance Thermal Camera

UMTI [UMTI USER MANUAL] User s Manual. Handheld Surveillance Thermal Camera Handheld Surveillance Thermal Camera UMTI User s Manual [UMTI USER MANUAL] Trademark Acknowledgements SATIR is trademark of SATIR Europe (Ireland) Ltd. Other names and products not mentioned above may

More information

FT-20 Fire Training Fog Machine User Manual English

FT-20 Fire Training Fog Machine User Manual English FT-20 Fire Training Fog Machine User Manual English 2018 Antari Lighting and Effects Ltd. 1 User Manual - English Safety Information Please read the following safety information carefully before operating

More information

Richter Optica. Instructions for Model F-1 Compound Microscope

Richter Optica. Instructions for Model F-1 Compound Microscope Richter Optica 6122 Innovation Way Carlsbad, California 92009 (800) 942-0528 US TOLL FREE (760) 438-0528 INTERNATIONAL Instructions for Model F-1 Compound Microscope Ocular Lens (eyepiece) Eyepiece Tube

More information

USER MANUAL. User Manual 17 / 19 LCD. NVP117 / NVP119 1U LCD Console Drawer. Options : - AV / DVI-D / HDMI / Audio - Full Range KVM - DC power

USER MANUAL. User Manual 17 / 19 LCD. NVP117 / NVP119 1U LCD Console Drawer. Options : - AV / DVI-D / HDMI / Audio - Full Range KVM - DC power USER MANUAL 17 / 19 LCD NVP117 / NVP119 1U LCD Console Drawer Options : - AV / DVI-D / HDMI / Audio - Full Range KVM - DC power Contents < Part. 1 > NVP117 / NVP119 1.1 Package Content 1.2 Structure Diagram

More information

PM-204A/B. Power Meter. Operation Guide

PM-204A/B. Power Meter. Operation Guide Power Meter Operation Guide Contents 1. Introduction...3 2. Warranty...3 3. Safety Information...3 4. Preparing for Operation...4 4.1. Unpacking the instrument...4 4.2. Discharged batteries...4 4.3. AC

More information

User Manual. Rack Mount Display Monitor - 4K RMP-161-4K17. 7U 17.3 inch Rack Mount Display Monitor

User Manual. Rack Mount Display Monitor - 4K RMP-161-4K17. 7U 17.3 inch Rack Mount Display Monitor User Manual Rack Mount Display Monitor - 4K RMP-161-4K17 7U 17.3 inch Rack Mount Display Monitor Options : - DC 9~36V power input - Touchscreen - AR hardness glass Contents < Part. 1 > RMB-17W-4K 1.1 Package

More information

Richter Optica. Instructions for Model: HSX1 High School Microscope

Richter Optica. Instructions for Model: HSX1 High School Microscope Richter Optica info@richter-optica.com Instructions for Model: HSX1 High School Microscope Eyepiece 360 Rotatable Head Objectives Carrying Handle Revolving Nosepiece Rack Stop Slide Holder Focus Tension

More information

ESV1200 Quantum Illuminator Cabinet INSTRUCTION MANUAL

ESV1200 Quantum Illuminator Cabinet INSTRUCTION MANUAL ESV1200 Quantum Illuminator Cabinet INSTRUCTION MANUAL Universal Power Supply ESV1200 Illuminated Cabinet Charts Charts HOTV Charts Letter Charts 2 ESV1200 Quantum Viewer Table Of Contents Introduction.......

More information

Prestigio P371 Users manual

Prestigio P371 Users manual Prestigio P371 Users manual 1. IMPORTANT INFORMATION WARNING: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS MONITOR TO LIQUIDS OR MOISTURE. HIGH VOLTAGE EXISTS ON THIS MONITOR. DO NOT REMOVE THE

More information

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution! 1170 POS SYSTEM 1170 INSTALLATION GUIDE Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution! This Installation Guide will help you efficiently install the 1170 POS. The document

More information

User Manual. Confocal System

User Manual. Confocal System User Manual Confocal System 503301 - User Manual for the Confocal System Contents 1. Introduction... 3 2. Safety Summary... 3 3. Trademarks and Copyrights... 4 4. Contact Information... 4 5. Documentation

More information

User Manual. Binocular Stereo Microscope. MicroscopeNet.com

User Manual. Binocular Stereo Microscope. MicroscopeNet.com User Manual Binocular Stereo Microscope Model K2213 Series MicroscopeNet.com Table of Contents i. Caution... 1 ii. Care and Maintenance... 1 1. Components Illustration... 2 2. Installation... 3 3. Operation...

More information

FTE-6000 Hand Held Tuneable Laser Source

FTE-6000 Hand Held Tuneable Laser Source FTE-6000 Hand Held Tuneable Laser Source USER S MANUAL Avoid Exposure Laser Radiation Emitted From The Aperture This product conforms to CDRH standards for laser product Per 21 CFR 1040.10 & 1040.11 Table

More information

INSTRUCTIONS. Congratulations on selecting your new Carson binoculars! Specifications

INSTRUCTIONS. Congratulations on selecting your new Carson binoculars! Specifications INSTRUCTIONS Congratulations on selecting your new Carson binoculars! With reasonable care, your binoculars will provide you with years of enjoyment. In order to achieve optimum performance, please read

More information

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

Video Borescope Inspection Camera

Video Borescope Inspection Camera User Manual Video Borescope Inspection Camera Model BR80 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech BR80 Video Borescope.

More information

AFC-3000 Automated Optical Connector Ferrule Cleaner

AFC-3000 Automated Optical Connector Ferrule Cleaner AFC-3000 Automated Optical Connector Ferrule Cleaner USER MANUAL AFC-3000 Automated Optical Connector Ferrule Cleaner User Manual 14 Heath Wood Lane, Chestnut Hill MA 02467-2685 US Tel +1 617 232-6224

More information

Power TracKer VII. User s Manual 2006 AVID. Multi Mode Reader. Manufactured under one or more of the following Patents:

Power TracKer VII. User s Manual 2006 AVID. Multi Mode Reader. Manufactured under one or more of the following Patents: Power TracKer VII User s Manual 2006 AVID Multi Mode Reader Manufactured under one or more of the following Patents: 5,235,326-5,266,926-5,559,507 6,172,609 FCC ID: IOL-134-AV1028 The device complies with

More information

fire cam 1080 user manual

fire cam 1080 user manual fire cam 1080 user manual OVERVIEW 1. LED 2. Power / Shutter 3. Rear Cap 4. Mode Switch 5. USB 6. Micro SD Card Slot 7. Battery 8. Microphone 9. 1080P / 720P Mode Switch INITIAL SET UP 1. Make sure the

More information

PIXIM Micro Dome Camera

PIXIM Micro Dome Camera PIXIM Micro Dome Camera DWC-MC355T ABOUT MANUAL Before installing and using the camera, please read this manual carefully. Be sure to keep it handy for future reference. 07132012 PRECAUTIONS Do not open

More information

Richter Optica. Instructions for Model: MDS2 Middle School Microscope

Richter Optica. Instructions for Model: MDS2 Middle School Microscope Richter Optica info@richter-optica.com Instructions for Model: MDS2 Middle School Microscope Eyepiece 360 Rotatable Head Revolving Nosepiece Carrying Handle Objectives Rack Stop Stage Stage Clips Disc

More information

User s Guide. RP7000S Series Single-Ended Active Probe. Nov RIGOL Technologies, Inc.

User s Guide. RP7000S Series Single-Ended Active Probe. Nov RIGOL Technologies, Inc. User s Guide RP7000S Series Single-Ended Active Probe Nov. 2013 RIGOL Technologies, Inc. Guaranty and Declaration Copyright 2013 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information RIGOL

More information

Visit us at

Visit us at TM PRO3000 Toner and Probe Users Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com PN 2440799 (English) October 2005 2005 Fluke

More information

Rev. F January 13, 1999 Part Number: OFL Operations Manual for the OFL 100 Mini-OTDR

Rev. F January 13, 1999 Part Number: OFL Operations Manual for the OFL 100 Mini-OTDR Rev. F January 13, 1999 Part Number: OFL1-00-1000 Operations Manual for the OFL 100 Mini-OTDR Contents Page 1.0 General Information... 1 1.1 Unpacking and Inspection... 1 1.2 Precautions... 1 1.3 Recommended

More information

Congratulations on selecting your new Carson binoculars!

Congratulations on selecting your new Carson binoculars! Congratulations on selecting your new Carson binoculars! With reasonable care, your binoculars will provide you with years of enjoyment. In order to achieve optimum performance, please read the instructions

More information

User Manual. 1U LCD Keyboard Drawer. KwikDraw - A Series. Manual. IT and Instrumentation for industry. - With KVM options - 15", 17, 19 screen size

User Manual. 1U LCD Keyboard Drawer. KwikDraw - A Series. Manual. IT and Instrumentation for industry. - With KVM options - 15, 17, 19 screen size User Manual 1U LCD Keyboard Drawer KwikDraw - A Series - With KVM options - 15", 17, 19 screen size 1.1 Important Safeguards Please read all of these instructions carefully before you use the device. Save

More information

DT-900 Techstrobe Operation Manual

DT-900 Techstrobe Operation Manual DT-900 Techstrobe Operation Manual Remove battery pack prior to recharging. Do not use the adapter as an external source for the techstrobe. DT-900 handheld stroboscope operates at HIGH VOLTAGE inside

More information

User Manual. Binocular Zoom Stereo Microscope with Boom Stand. MicroscopeNet.com

User Manual. Binocular Zoom Stereo Microscope with Boom Stand. MicroscopeNet.com User Manual Binocular Stereo Microscope with Boom Stand Model W42C1 Series MicroscopeNet.com Table of Contents i. Caution.. 1 ii. Care and Maintenance... 1 1. Component Illustration... 2 2. Installation...3

More information

CS Contractor Series Live PON OTDR

CS Contractor Series Live PON OTDR CS260-10 Contractor Series Live PON OTDR User Guide www.aflglobal.com or (800) 321-5298, (603) 528-7780 Table of Contents Safety Information... 4 General Information... 5 Contacting Customer Service...5

More information

VGA RESOLUTION PROBE USER S MANUAL

VGA RESOLUTION PROBE USER S MANUAL VGA RESOLUTION PROBE USER S MANUAL P16181HP P16182HP P16183HP Please read this manual carefully and thoroughly before using this product. TABLE OF CONTENTS Introduction.......................................

More information

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR National Optical & Scientific Instruments Inc. 6508 Tri-County Parkway Schertz, Texas 78154 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR MODEL 205-RLED (formerly Model 205) COMPOUND MICROSCOPE

More information

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR National Optical & Scientific Instruments Inc. 6508 Tri-County Parkway Schertz, Texas 78154 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR MODELS #446TBL, #447TBL AND #448TBL STEREOSCOPIC MICROSCOPES

More information

VADDIO /CANON BU-SERIES PTZ CAMERAS

VADDIO /CANON BU-SERIES PTZ CAMERAS Camera and Electronic Products for Integrators Installation and User Guide VADDIO /CANON BU-SERIES PTZ CAMERAS Canon BU-45H Outdoor & BU-50H Indoor PTZ Cameras including Vaddio accessories for easy integration

More information

Handheld Video Magnifier

Handheld Video Magnifier Zoomax TM Snow Handheld Video Magnifier V1.1 1 Contents Description...3 Accessories...3 Compositions:...4 Operation...5 Battery installation...5 Charging the battery...6 Install short strap...6 Operation

More information

PMI Borescope Lizard 100 Series User Guide

PMI Borescope Lizard 100 Series User Guide PMI Borescope Lizard 100 Series User Guide Thank you very much for purchasing Lizard 100 borescope. Be sure to read this Instruction manual before using, for operating it safely and correctly. Please keep

More information

Table of Contents. Chapter 1. Safety Precautions Notice Chapter 2. Components and accessories Chapter 3. Camera components...

Table of Contents. Chapter 1. Safety Precautions Notice Chapter 2. Components and accessories Chapter 3. Camera components... P. 770.270.1394 F. 770.270.2389 865 Marathon Parkway Lawrenceville GA 30046 P. 770.270.1394 F. 770.270.2389 865 Marathon Parkway Lawrenceville GA 30046 Table of Contents Chapter 1. Safety Precautions Notice...

More information

To connect the AC adapter:

To connect the AC adapter: Replacing the AC Adapter Replacing the AC Adapter 3 Plug the power cord into a wall outlet. The power indicator turns on. To connect the AC adapter: Connect the power cord to the AC adapter. Power indicator

More information

Operation Manual. for Micromas ter I Micros copes. T his manual covers catalog numbers : S 11031, S 11033, and S 11035

Operation Manual. for Micromas ter I Micros copes. T his manual covers catalog numbers : S 11031, S 11033, and S 11035 Operation Manual for Micromas ter I Micros copes T his manual covers catalog numbers : S 11031, S 11033, and S 11035 General Operation Thank you for purchasing a Micromaster I microscope. This instrument

More information

PA Series. Available in 6.0MP and 8.0MP

PA Series. Available in 6.0MP and 8.0MP Camera Quick Install Guide PA Series Available in 6.0MP and 8.0MP Thank you for purchasing a PA Series CCTV Surveillance Camera. This Quick Install Guide covers basic setup, installation and use of your

More information

WallVIEW PTZ Systems WallVIEW 50i PTZ, WallVIEW 100 PTZ and WallVIEW 70 PTZ Pan/Tilt/Zoom Camera Systems

WallVIEW PTZ Systems WallVIEW 50i PTZ, WallVIEW 100 PTZ and WallVIEW 70 PTZ Pan/Tilt/Zoom Camera Systems Camera and Electronic Products for Integrators Installation and User Guide WallVIEW PTZ Systems WallVIEW 50i PTZ, WallVIEW 100 PTZ and WallVIEW 70 PTZ Pan/Tilt/Zoom Camera Systems Figure 1: WallVIEW Systems

More information

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power Critical Power USER MANUAL Uninterruptible Power Supply Line-interactive VCL Series UPS 400 600 800 1000 1500 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland

More information

COBEX RECORDERS, INC.

COBEX RECORDERS, INC. INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS FOR CIRCULAR CHART RECORDERS COBEX RECORDERS, INC. CAUTION: IT IS IMPORTANT THAT THESE INSTRUCTIONS BE READ BEFORE INSTALLING THE INSTRUMENT. KEEP THESE

More information

TABLET DOCK USER S GUIDE

TABLET DOCK USER S GUIDE Fujitsu Stylistic ST5100 Series Tablet PC TABLET DOCK USER S GUIDE Warning Handling the cord on this product will expose you to lead, a chemical known to the State of California to cause birth defects

More information