Modular Block Converter Systems

Size: px
Start display at page:

Download "Modular Block Converter Systems"

Transcription

1 SATCOM Technologies Modular Block Converter Systems C-Band Hot-swappable, plug-in upconverter and downconverter modules Dual, redundant, hot-swappable power supplies Excellent frequency stability over temperature Built-in monitoring of individual modules and overall system performance ternal/external auto-switch 5 or 10 MHz reference Overview The General Dynamics SATCOM Technologies Modular Block Converter (MBC) System eliminates downtime and maximizes performance and ease of repair by providing fully modular systems for up conversion or down conversion. Leveraging patented technology and field-proven architecture, all of the critical system components are hot-swappable without the removal of power and can be removed from the front of the chassis with the exception of the fan assembly which is accessible from the rear panel. Hot-Swappable Architecture The converters can be configured for single-thread operation or for 1:1 or 1:2 redundancy. a redundant system, a backup converter can be switched in automatically or manually to replace a faulted unit; the faulted module may be removed and replaced while the others remain operational. The system design leverages a blindmate backplane for front panel removal for converters, power supplies, logic card, and color touchscreen. The design enables fast and easy repair with continuous operation, achieving MTTR of less than 3 minutes. Features nfront hot-swappable plug-in modules (RF, PS, touch screen, and logic card) navailable in stand-alone, 1:1 redundancy, and 1:2 redundancy configurations ncolor touch-screen user interface ntcp/ip embedded page to monitor and control system functions, and send alerts nethernet or Serial I/O M&C interface nstandard 19 rack panel, 3.5 high (2 RU), with 22 chassis slides; chassis is 24 deep Preliminary

2 User terface Leading Edge Software The MBC is equipped with a color touch-screen for local control along with a leading-edge TCP/IP embedded Web Page software package. The software can be configured for remote monitoring, while allowing virtual factory access to monitor the converter modules key performance parameters such as temperature, current, and voltage. The user interface features secure login with user privilege level controls. nconverter modules feature an autoselection reference that automatically phase locks to an external 5 or 10 MHz reference when present, or uses its internal high stability reference when the external reference is not detected. nbuilt-in RF module monitoring & control capabilities: ngain Adjust or attenuation control nexternal Reference Level nexternal Reference Frequency nreference Phase Lock nlo Phase Lock nmodule Current nmodule -On Self-Test nmodule Temperature RF Module Bands nconverters put LO Frequency put Model GHz 5.15 GHz nconverters MHz (inverted) DCDX put LO Frequency put Model MHz 4.9 GHz GHz UCBX Operating Functions nmonitors and controls two or three redundant RF modules of a single type in either a 1:1 (two module) or 1:2 (three module) configuration. nmonitors and controls one or two independent, single-thread modules. nmonitors the internal power supply modules for faults. nfront panel controls and status indicators nethernet terface: nsnmpv1/2/3 nhttp (Web page) nfirmware dates via secure protocol nrs-232/485/422 Serial terface nredundant Control Modes: nauto Mode: A faulted RF module is automatically switched off line and replaced with the backup unit. nmanual Mode: Allows manual control over which unit is online, via the front panel, serial port, or network. Auto-recovery and Sparing nthe MBC senses loss-of-lock conditions and component failures to initiate switching to a redundant converter. Users have the capability of setting up alert s, along with remote monitoring capability via embedded TCP/IP web status pages. Replacement of any component can be accomplished within minutes. nsparing of the MBC is dependent upon the user. nactive components nconverter nlogic Board n Supply ntouchscreen nfan Assembly Cooling Fans n The MBC has two cooling fans mounted on an easy-to-replace fan assembly.

3 Modular Block Converter Systems MBC System Block Diagrams n1-for-1 (1:1) Redundant converter System n1-for-2 (1:2) Redundant converter System Supply #1 Supply #1 Supply #2 Passive Splitter 10 MHz Ext Ref Supply #2 Passive Splitter 10 MHz Ext Ref Pol #1 Converter #1 Converter #2 Blindmate Backplane Online Online Offline Converter #1 Converter #3 Converter #2 Blindmate Backplane Pol #1 Offline Offline Pol #2 Touch Screen Local Control Offline Touch Screen Local Control Pol #2 Main Logic Board = Front panel access for ease of replacement Switch Assembly Main Logic Board Switch Assembly = Front panel access for ease of replacement n1-for-1 (1:1) Redundant converter System n1-for-2 (1:2) Redundant converter System Supply #1 Supply #2 Passive Splitter 10 MHz Ext Ref Supply #1 Supply #2 Passive Splitter 10 MHz Ext Ref Pol #1 Converter #1 Converter #2 Touch Screen Local Control Blindmate Backplane Online Online Offline Offline Converter #1 Converter #3 Converter #2 Touch Screen Local Control Blindmate Backplane Pol #1 Offline Offline Pol #2 Pol #2 Main Logic Board = Front panel access for ease of replacement Switch Assembly Main Logic Board Switch Assembly = Front panel access for ease of replacement

4 converter Module Performance Parameter Notes Min. Nom./Typ. Max. Units RF put At maximum gain -10 m RF put VSWR IF put VSWR Ratio Return Loss 19.1 Ratio Return Loss :1 1.5 :1 LO Leakage -50 m Reference put Frequency Auto Detect 5 or 10 MHz Reference put At module m put at 1 Compression (P 1 ) IF put, at max. gain m 3rd Order tercept Point IF put, at max. gain m Gain At max. gain setting Gain Step Resolution 0.5 Adjustable Gain Range 25 Gain Flatness Gain Stability -Band Spurious Full band, at max. gain Per 40 MHz, at max. gain Over temperature Per week, constant temp. Per week and over temp. Signal-related Non-signal-related Harmonics At IF c Noise Figure At maximum gain Temperature Range Voltage Operating Storage ± 1.0 ± 0.5 ± 1.5 When there is only one value on a line, the Nom./Typ. column is a nominal value; otherwise it is a typical value. Typical values are intended to illustrate typical performance, but are not guaranteed. Reference Performance 0-40 Parameter Notes Min. Nom./Typ. Max. Units ternal Reference Standard Aging per day Aging after 10 years External Reference Requirements Frequency Frequency Tolerance Level Impedance Ref PLL Bandwidth Ext. Ref. Phase Noise Req to +50 C ±30 ±1 ±500 All subbands At module 10 Hz Offset 100 Hz Offset 1 khz Offset 10 khz Offset or 10 ±0.5 When there is only one value on a line, the Nom./Typ. column is a nominal value; otherwise it is a typical value. Typical values are intended to illustrate typical performance, but are not guaranteed. 50 ± 1 ± c m Vdc W C C MHz ppm m ohms Hz m/hz m/hz m/hz m/hz

5 Modular Block Converter Systems converter Module Performance Parameter Notes Min. Nom./Typ. Max. Units IF put -7 m IF put VSWR RF put VSWR Ratio Return Loss 14 Ratio Return Loss : :1 LO Leakage -50 m Reference put Frequency Auto Detect 5 or 10 MHz Reference put At module m put at 1 Compression (P 1 ) RF put, at max. gain m 3rd Order tercept Point RF put, at max. gain m Gain At max. gain setting Gain Step Resolution 0.5 Adjustable Gain Range 25 Gain Flatness Gain Stability -Band Spurious Full band, at max. gain Per 40 MHz, at max. gain Over temperature Per week, constant temp. Per week and over temp. Signal-related Non-signal-related Noise Figure At maximum gain Temperature Range Voltage Operating Storage ± 1.0 ± 0.5 ± 1.5 When there is only one value on a line, the Nom./Typ. column is a nominal value; otherwise it is a typical value. Typical values are intended to illustrate typical performance, but are not guaranteed ± 1 ± c m Vdc W C C Reference Performance Parameter Notes Min. Nom./Typ. Max. Units ternal Reference Standard Aging per day Aging after 10 years External Reference Requirements Frequency Frequency Tolerance Level Impedance Ref PLL Bandwidth Ext. Ref. Phase Noise Req. 0 to +50 C ±30 ±1 ±500 All subbands At module 10 Hz Offset 100 Hz Offset 1 khz Offset 10 khz Offset or 10 ±0.5 When there is only one value on a line, the Nom./Typ. column is a nominal value; otherwise it is a typical value. Typical values are intended to illustrate typical performance, but are not guaranteed MHz ppm m ohms Hz m/hz m/hz m/hz m/hz

6 Phase Noise Performance Maximum c/hz at converter converter 10 Hz Offset Hz Offset khz Offset khz Offset khz Offset MHz Offset System Performance The redundant modular block downconverter or upconverter system generally has the same performance as the individual converter modules with the following exceptions: Parameter RF port VSWR IF port VSWR System RF Losses (typ.) System IF Losses (typ.) Gain Flatness (typ.) Noise Figure Reference put Specification 1.3:1 max. (17.7 RL) 1.9:1 max. (10.1 RL) 2 1 Add ±0.3 to module specification Add +2 to module specification -5 to +5 m; 0 m typical Supply Parameter Specification AC put (dual line input) Vac, Hz; 60 W typical DC put 12 V, 250 W over 0 to +50 C Connector terfaces Parameter Specification RF/IF put Type N, 50 ohms (standard); SMA, 50 ohms (option) IF/RF put Type N, 50 ohms (standard); SMA, 50 ohms (option) 10 MHz External Reference put BNC Female Network RJ-45/CAT 5 Ethernet Serial I/O DB-9 (RS-232, RS-422, RS-485:2, RS-485:4)

7 J4 J5 J6 WARNING Hazardous moving parts Keep away from moving fan blades J1 J2 J3 J7 Modular Block Converter Systems line Drawing [667] 0.65 [16] [606] AC 2 AC 1 AC INPUT: Vac, Hz IEC :C14 FACTORY USE ONLY / V; 6.0/3.0A; 50/60 Hz - Fusing V: 250V 6.3A SLO-BLO V: 250V 3.15A SLO-BLO - Consult O&M manual for installation instructions. - Refer servicing to qualified personnel. USB - FIRMWARE UPGRADE PORT NETWORK CAN SERIAL I/O SERIAL I/O - DB9 GND TERMINAL - #8-32 HARDWARE PROVIDED WIRE SIZE: GA NETWORK - CAT 5 ETHERNET REMOVE DISPLAY TO ACCESS POWER SUPPLY MODULES REAR PANEL AIR EXHAUST POINTS DANGER RISK OF ELECTRIC SHOCK. Disconnect all sources of supply prior to servicing [483] [461] STATUS ONLINE MODULE 2 J1-6 TYPE N (F) - 50 OHM SEE CHART STATUS ONLINE MODULE 3 (OFFLINE) SEE NOTE 2 - CONNECTOR OPTION STATUS ONLINE MODULE 1 10 MHz EXTERNAL REFERENCE INPUT BNC (F) - 50 OHM MBC-2XXXX-X BLOCK CONVERTER RF: XX.XX-XX.XX GHz LO: XX.XX GHz IF> XXX-XXXX MHz IF/RF CONNECTORS: DESIGNATOR FUNCTION J1 POL 1 IN J2 OFFLINE IN J3 POL 2 IN DESIGNATOR FUNCTION J4 POL 1 OUT J5 OFFLINE OUT J6 POL 2 OUT NOMINAL LENGTH 22 [559] EXTENDED LENGTH 44 [1118] MAX [11] 1.75 [44] 0.86 [22] 3.47 [88] NOTES: 1. DIMENSIONS ARE IN INCHES [MM]. 2. SMA CONNECTOR (50 OHM) OPTION AVAILABLE. 3. CHASSIS WEIGHT, INCLUDING SLIDES (WITH NO RF MODULES INSTALLED) IS APPROXIMATELY 21.8 lb (9.9 kg). CHASSIS WEIGHT WITH 3 RF MODULES INSTALLED IS APPROXIMATELY 32.4 lb (14.7 kg). 4. MATING CONNECTORS INCLUDED BUT NOT SHOWN. AIR INTAKE POINTS ALONG FRONT PANEL Part Number/Ordering formation Top-Level Configuration cludes rack chassis with 2 power supply modules and choice of 1 (single-thread), 2 (1:1 redundant), or 3 (1:2 redundant) RF modules: Configuration Single-thread, no redundancy (1 RF module)...x 1:1 Redundant (2 identical RF modules)...1 1:2 Redundant (3 identical RF modules)...2 Module Identifier (see below)...xxxx Rear Panel RF connectors Type N, 50 ohms (Standard)...X SMA, 50 ohms (Option) Note: Standard configuration includes only one type of RF module per chassis. RF Modules... To order single modules separately: MBC- BCM- converters C-Band GHz in, 5.15 GHz LO, MHz out... DCDX (inverted spectrum) converters C-Band MHz in, 4.9 GHz LO, GHz out... UCBX Note: To order a blank module cover plate, use part number MPAN PS modules can also be ordered separately, part number AMAX Spares Kit cludes 1 Fan Assembly, 1 Supply Module, 1 Logic Module, and 1 Display Module. Converter modules sold separately.

8 SATCOM Technologies Phone: General Dynamics. All rights reserved. General Dynamics reserves the right to make changes in its products and specifications at anytime and without notice. All trademarks indicated as such herein are trademarks of General Dynamics. All other product and service names are the property of their respective owners. Reg. U.S. Pat. and Tm. Off Rev. - Preliminary

S-Band Redundant LNA Systems

S-Band Redundant LNA Systems S-Band Redundant LNA Systems LRS-1000 Series Introduction Redundant LNA systems minimize system downtime due to LNA failure by providing a spare LNA and an automatic means of switching to the spare upon

More information

Cisco Prisma II Platform

Cisco Prisma II Platform Cisco Prisma II Platform In optical transmission systems, the network platform forms the foundation of the product family. The Cisco Prisma II platform provides network operators with the unique features

More information

Ku-Band Solid-State Power Amplifier

Ku-Band Solid-State Power Amplifier PKM14S200R Ku-Band Solid-State Power Amplifier This high power solid-state amplifier offers an output power of 200 watts across the standard 14.0 to 14.5 GHz satellite uplink band. Built for reliable,

More information

Prisma II Platform. Optoelectronics

Prisma II Platform. Optoelectronics Optoelectronics Prisma II Platform Description In optical transmission systems, the network platform forms the foundation of the product family. The Prisma II platform provides network operators with the

More information

Compact Redundancy Switch 2:1 RSCC-2

Compact Redundancy Switch 2:1 RSCC-2 Compact Redundancy Switch 2:1 RSCC-2 The WORK Microwave Redundancy Switch RSCC-2 is compact solution for a 2:1 Redundancy System. It can be used for upconverters, downconverters, modulators and modulator-upconverters.

More information

Compact Redundancy Switch 2:1 RSCC-2

Compact Redundancy Switch 2:1 RSCC-2 Compact Redundancy Switch 2:1 RSCC-2 The WORK Microwave Redundancy Switch RSCC-2 is a compact solution for a 2:1 redundancy system. It can be used for upconverters, downconverters and with special firmware

More information

C-Band Solid-State Power Amplifiers

C-Band Solid-State Power Amplifiers PCD6S350R, PCD6S400R C-Band Solid-State Power Amplifiers These high power solid-state amplifiers offer output powers of 350 or 400 watts across the standard 5.850 to 6.425 GHz satellite uplink band. Built

More information

Redundancy Switch Controller 1:1 RSCM1

Redundancy Switch Controller 1:1 RSCM1 Visit us at www.work-microwave.com Redundancy Switch Controller 1:1 The WORK Microwave redundancy switch 1:1 is used for 1:1 redundancy configurations for Upconverters, Downconverters, Modulator-Upconverters,

More information

Instruction Manual Model Block Translator

Instruction Manual Model Block Translator Instruction Manual Model 2083-1010 Block Translator May 2018, Rev. 0 1250>1200 G=-10.0 REF = AUTO - I MENU MODEL 2083 TRANSLATOR CROSS TECHNOLOGIES INC. REMOTE POWER ALARM EXECUTE Data, drawings, and other

More information

1:1 C-Band LNA Redundancy System

1:1 C-Band LNA Redundancy System RSS1:1-C General Description : The Orbital redundant switch system was designed to minimize system outage using a waveguide, coaxial switche to provide a spare in the event of a failure. Various configurations

More information

Series 8000 RF Signal Switch Solution

Series 8000 RF Signal Switch Solution RF Signal Switch Solution Operation Manual Operation Manual, Part Number 07508000 006, Rev. B, Oct 7, 2014 All technical data and specifications in this publication are subject to change without prior

More information

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1584-25 Splitter December 2009 Rev B MITOR 1 MITOR 2 A B MODEL 1584 DIVIDER CROSS TECHNOLOGIES C. Data, drawings, and other material contained herein are proprietary to Cross Technologies,

More information

SLC ultra low jitter Clock Synthesizer 2 MHz to 7 GHz

SLC ultra low jitter Clock Synthesizer 2 MHz to 7 GHz SLC ultra low jitter Clock Synthesizer 2 MHz to 7 GHz Datasheet The SLC is a very affordable single or dual clock 7 GHz synthesizer that exhibits outstanding phase noise and jitter performance in a very

More information

464K PRELIMINARY 3-STAGE SOLID STATE SWITCH SYSTEMS 464K SALIENT FEATURES SYSTEM OPERATION 464K DESCRIPTION

464K PRELIMINARY 3-STAGE SOLID STATE SWITCH SYSTEMS 464K SALIENT FEATURES SYSTEM OPERATION 464K DESCRIPTION 3-STAGE SOLID STATE SWITCH SYSTEMS PRELIMINARY SALIENT FEATURES SYSTEM OPERATION 3-stage non-blocking solid state switch matrix High density: 65,536 equivalent crosspoints in one mainframe Built-in self

More information

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1582-10M Protection Switch January 2009 Rev O ALARMS MENU OUTPUT = CH1 AUTO POWER 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 CH2 REMOTE EXECUTE Data, drawings, and other

More information

Series 8000 RF Signal Switch Solution

Series 8000 RF Signal Switch Solution RF Signal Switch Solution Operation Manual Operation Manual, Part Number 07508000-006, Rev. A, May 17, 2013 All technical data and specifications in this publication are subject to change without prior

More information

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF Instruction Manual Model 2082-1972 Power Supply July 2012, Rev. B MODEL 2082 POWER SUPPLY CROSS TECHNOLOGIES INC. PRIMARY PWR AC BUC +48V AUX BUC TX SELECT 48V +18V/48V LNB RX +18V ANT CNTR +29V AC 18V

More information

NI PXIe-1062Q Power Supply Shuttle

NI PXIe-1062Q Power Supply Shuttle USER GUIDE NI PXIe-1062Q Power Supply Shuttle The NI PXIe-1062Q power supply shuttle is a replacement part for the NI PXIe-1062Q chassis. Caution This power supply is not compatible with any other National

More information

Cisco DCM Series D9901 Digital Content Manager IP Video Gateway

Cisco DCM Series D9901 Digital Content Manager IP Video Gateway Cisco DCM Series D9901 Digital Content Manager IP Video Gateway Today s video contribution networks are evolving rapidly with the dual drivers of increased demand, for high-definition TV, and a need for

More information

LASER PLUS OPERATING INSTRUCTIONS

LASER PLUS OPERATING INSTRUCTIONS LASER PLUS OPERATING INSTRUCTIONS Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 E-Mail: salessupport@olsontech.com 025-370403 REV X9 www.olsontech.com 12/16/03 TABLE OF CONTENTS SYSTEM OVERVIEW

More information

Each amplifier can be remote controlled via the standard IEEE-488 GPIB.

Each amplifier can be remote controlled via the standard IEEE-488 GPIB. SOLID-STATE AMPLIFIERS A330/A340 SERIES 20 WATTS CW 1.0 GHz - 4.0 GHz DESCRIPTION The 3.5" high A330 series and the 5.25" high A340 series of medium power microprocessor based instrumentation and subsystem

More information

ELECTROMECHANICAL SWITCH MATRICES

ELECTROMECHANICAL SWITCH MATRICES ELECTROMECHANICAL SWITCH MATRICES Electromechanical MS-Series Multiple Switches 1RU Model 2RU Model Features Configuration Operating Manual Control Remote Control Impedance Multiple Switches (bidirectional):

More information

TABLE OF CONTENTS 1. OVERVIEW... 1

TABLE OF CONTENTS 1. OVERVIEW... 1 TABLE OF CONTENTS 1. OVERVIEW... 1 1.1. SPECIFICATIONS... 1 1.1.1. Electrical... 1 1.1.2. Compliance... 2 1.1.3. Physical... 2 1.2. COOLING... 2 1.2.1. Fan Exhaust... 2 1.3. MOUNTING... 3 1.4. POWER...

More information

Series 8900 LAN. Operation Manual. Part Number (example configuration) Part Number (example configuration)

Series 8900 LAN. Operation Manual. Part Number (example configuration) Part Number (example configuration) Series 8900 LAN Part Number 90570300 (example configuration) Part Number 90570300-001 (example configuration) Operation Manual Operation Manual, Part Number 07508900-001, Rev. B, February 26, 2013 All

More information

464kB SOLID STATE SWITCH SYSTEMS. 464kB SALIENT FEATURES SYSTEM OPERATION. 464kB DESCRIPTION

464kB SOLID STATE SWITCH SYSTEMS. 464kB SALIENT FEATURES SYSTEM OPERATION. 464kB DESCRIPTION SOLID STATE SWITCH SYSTEMS SALIENT FEATURES 3-stage non-blocking solid state switch matrix High density: 65,536 equivalent cross points in one mainframe sizes to meet unique requirement:, 224 x 224, 192

More information

464kA. 256x256 SOLID STATE SWITCH SYSTEMS. 464kA SALIENT FEATURES SYSTEM OPERATION. 464kA DESCRIPTION

464kA. 256x256 SOLID STATE SWITCH SYSTEMS. 464kA SALIENT FEATURES SYSTEM OPERATION. 464kA DESCRIPTION 256x256 SOLID STATE SWITCH SYSTEMS SALIENT FEATURES 3-stage non-blocking solid state switch matrix High density: 65,536 equivalent cross points in one mainframe Bus frames to form larger systems Built-in

More information

464kC SOLID STATE SWITCH SYSTEMS. 464kc SALIENT FEATURES SYSTEM OPERATION. 464kC DESCRIPTION

464kC SOLID STATE SWITCH SYSTEMS. 464kc SALIENT FEATURES SYSTEM OPERATION. 464kC DESCRIPTION 464kC SOLID STATE SWITCH SYSTEMS 464kc SALIENT FEATURES 3-stage non-blocking solid state switch matrix High density: 65,536 equivalent cross points in one mainframe sizes to meet unique requirement:, 224

More information

Cisco MCS 7845-H1 Unified CallManager Appliance

Cisco MCS 7845-H1 Unified CallManager Appliance Data Sheet Cisco MCS 7845-H1 Unified CallManager Appliance THIS PRODUCT IS NO LONGER BEING SOLD AND MIGHT NOT BE SUPPORTED. READ THE END-OF-LIFE NOTICE TO LEARN ABOUT POTENTIAL REPLACEMENT PRODUCTS AND

More information

CPCI System Subrack 3 U

CPCI System Subrack 3 U User s Manual Product No.: Doc-No: 63972-224_R1.1 April 18, 2011 Rev. Date updated Change R1.0 January 14, 2008 Initial Release R1.1 April 18, 2011 Fan Tray with mini compression latch Impressum: Schroff

More information

Summit Virtual Chassis Design and Installation Guide

Summit Virtual Chassis Design and Installation Guide Summit Virtual Chassis Design and Installation Guide Extreme Networks, Inc. 10460 Bandley Drive Cupertino, California 95014 (888) 257-3000 http://www.extremenetworks.com Published: June 1998 Part No: 120031-00

More information

4164 Switch Matrix System Description

4164 Switch Matrix System Description On the New Frontiers of Precision A Quantum Switch for the Better Precision 4164 Switch Matrix High Density Programmable 64x64 Switch Matrix System The Precision 4164 Switch Matrix System is a reliable

More information

A0750 AC-DC POWER MODULE

A0750 AC-DC POWER MODULE FEATURES High power density, 7.7W / in³ Net Weight:< 2.2 KG Low profile : 40.8mm (fit 1U 19 shelf R2250 series) Efficiency: 77% ~ 86 % typical Power factor correction (meet IEC1000-3-2 requirements) Overvoltage

More information

FS2000 Series Fast Switching Synthesizer

FS2000 Series Fast Switching Synthesizer Supports hundreds of fast switching, high spectral purity applications. Features: Ultra-fast Switching

More information

CPCI System Subrack 1 U

CPCI System Subrack 1 U User s Manual Product No.: Doc-No: 63972-165_R1.0 January 14, 2008 Rev. Date updated Change R1.0 January 14, 2008 Initial Release Impressum: Schroff GmbH D-75334 Straubenhardt, Germany The details in this

More information

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE Introduction Unpacking The NI PXI-1042 power supply shuttle is a replacement part for the PXI-1042 chassis. To minimize downtime caused by a power-supply failure,

More information

3+1 U CPCI Serial System

3+1 U CPCI Serial System 3+ U CPCI Serial System User s Manual Product Number: 4579-46/47/48/49/40/4/4/43/44 Doc-No: 6397-349_R.0 January 06 R.0 January 06 Initial Release Impressum: Schroff GmbH Langenalber Str. 96-00 75334 Straubenhardt,

More information

Installing the IPS 4345 and IPS 4360

Installing the IPS 4345 and IPS 4360 CHAPTER 4 Installing the IPS 4345 and IPS 4360 Contents This chapter describes the Cisco IPS 4345 and the IPS 4360, and includes the following sections: Installation Notes and Caveats, page 4-1 Product

More information

CMX18 FEATURES A 18-SLOT 3U PXI EXPRESS CHASSIS

CMX18 FEATURES A 18-SLOT 3U PXI EXPRESS CHASSIS 83-0062-000 15A D A T A S H E E T CMX18 18-SLOT 3U PXI EXPRESS CHASSIS FEATURES 18-slot PXI Express chassis with 1 system controller slot, 6 peripheral slots, 10 hybrid slots, and 1 timing slot High bandwidth

More information

CSPS-6K (Shelf Type) POWER you need POWER SHELF

CSPS-6K (Shelf Type) POWER you need POWER SHELF CSPS-6K (Shelf Type) REV: 081418 SHELF PRODUCT FEATURES: Hot pluggable n+1 Redundancy Controlled, measured and reported by TCP/IP Modular design for accommodating high power applications 19 Inch Rack Mount

More information

VME64x System Subrack 8 U

VME64x System Subrack 8 U User s Manual Product No.: Doc-No: 63972-158 Revision: R1.1, November 14, 2008 Rev. Date updated Change R1.0 November 19, 2007 Initial release R1.1 November 14, 2008 Part no. FCM added Impressum: Schroff

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

CAN enabled The retifier can be monitored and controlled through analogue signals. It is also equipped with a CAN signal bus.

CAN enabled The retifier can be monitored and controlled through analogue signals. It is also equipped with a CAN signal bus. D CAR0948TN -48V/850W rectifier Product Features High power density: 19.2W / inch delta; 1160W/L Constant output power Fits in 19 high, ETSI compliant Wide input range (90VAC 280VAC) Outdoor operating

More information

The SFP BG meets international safety requirements and is CE marked to the Low Voltage Directive (LVD). Datacom Distributed Power Systems

The SFP BG meets international safety requirements and is CE marked to the Low Voltage Directive (LVD). Datacom Distributed Power Systems Ideal server form factor optimizes, space, efficiency, and load variations High efficiency maximized between 30-80% load conditions Unconditionally stable under any load condition Wide input voltage range

More information

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-CH Rev. X1 E-Mail: salessupport@olsontech.com

More information

Installation Job Aid for VSP 4450GTX-HT- PWR+

Installation Job Aid for VSP 4450GTX-HT- PWR+ Installation Job Aid for VSP 4450GTX-HT- PWR+ Notices Release 6.1.0.0 NN46251-305 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output MODEL NUMBER: SU10KRT3/1X Highlights 10,000VA (10kVA) SmartOnline 6U rack/tower UPS 3 phase, 4-Wire + Ground,

More information

IFL MICROWAVE PHOTONICS LINKS TO 30 GHZ

IFL MICROWAVE PHOTONICS LINKS TO 30 GHZ MICROWAVE PHOTONICS LINKS TO 30 GHZ WDM MUX AND DEMUX NETWORKS DUAL REDUNDANT POWER SUPPLIES FULLY HOT SWAPPABLE UPTO SIXLINK MODULESPER 1RURACK RACK IFL interfacility ilit link systems Linear Photonics

More information

DX/256x256 SERIES SOLID STATE DIGITAL SWITCHING SYSTEMS

DX/256x256 SERIES SOLID STATE DIGITAL SWITCHING SYSTEMS BULLETIN DX256-2 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 sales@cytec-ate.com DX/256x256 SERIES SOLID STATE DIGITAL SWITCHING SYSTEMS CYTEC's DX/256x256 Series Switching Systems are based

More information

CAR0548TN. Product Features. Benefits. -48V/ 500W rectifier

CAR0548TN. Product Features. Benefits. -48V/ 500W rectifier -48/ 500W rectifier Product Features Constant output power Universal input No derating at low mains Extended temperature range Active load sharing Hot swap- fault tolerant Worldwide certification Benefits

More information

RT12-240V/2.4kW Rectifier Specification

RT12-240V/2.4kW Rectifier Specification The RT12-240V/2.4kW is a switched mode rectifier (SMR) module that delivers up to 2.4kW of output power (and up to 11A output current) into a 240V nominal DC system. The RT12 suits AC supply voltages between

More information

Procedure to Install an IO Expansion Cage Assembly in a Maxum II Modular Oven Analyzer

Procedure to Install an IO Expansion Cage Assembly in a Maxum II Modular Oven Analyzer Procedure to Install an IO Expansion Cage Assembly in a Maxum II Modular Oven Analyzer Difficulty Level: Medium Estimated time to execute: 1 Hour Revision History Issue Date Reason 001 5/31/2016 Initial

More information

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents. User Guide CPSMP-205 110 240 VAC Power Supply Module: PointSystem CPSMC1800-200 Accessory CPSMC1900-100 Accessory Contents Contents...1 Description...1 Cautions and Warnings...2 Definitions...2 Power supply

More information

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter ClearCube FO-065-1200 series 12-Port Media Converter ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter User s Manual 1 ClearCube Connectivity Systems F6151 Media Converter

More information

VME64x System Subrack 1 U

VME64x System Subrack 1 U User s Manual Product No.: Doc-No: 63972-157_R1.0 November 09, 2007 Rev. Date updated Change R1.0 November 09, 2007 Initial Release Impressum: Schroff GmbH D-75334 Straubenhardt, Germany The details in

More information

DISTRIBUTION AMPLIFIER SYSTEMS

DISTRIBUTION AMPLIFIER SYSTEMS 99984 DISTRIBUTION AMPLIFIER SYSTEMS 99984 SYSTEM SALIENT FEATURES 128 differential inputs 16 differential input cables with 26-pin HD connectors 896 buffered, SE outputs with ground sense (seven groups

More information

RADIAN TPCMQ24 SERIES 24VDC Input 1RU Rack-Mount DC-DC Front-Ends 1000W and 1200W 1000W INDUSTRIES & APPLICATIONS

RADIAN TPCMQ24 SERIES 24VDC Input 1RU Rack-Mount DC-DC Front-Ends 1000W and 1200W 1000W INDUSTRIES & APPLICATIONS RADIAN TPCMQ24 SERIES 24VDC Input 1RU Rack-Mount DC-DC Front-Ends 48DC @ 1000W and 1200W 54.4VDC @ 1000W INDUSTRIES & APPLICATIONS FEATURES Telecom Cable Utilities Government Industrial Isolated 5V, ¼

More information

Specification Sheet S2561E-001 Single-Ended Flexible 256x256 Analog Switching Array Building Block to 1024x1024 System S2561E

Specification Sheet S2561E-001 Single-Ended Flexible 256x256 Analog Switching Array Building Block to 1024x1024 System S2561E Specification Sheet S256E-00 Single-Ended Flexible 256x256 Analog Switching Array Building Block to 024x024 System S256E January 2009 Applications Audio, Data or Video routing E audio switching Production

More information

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply Sorensen DLM 600 Series Half Rack Programmable DC Power Supply high, half rack (8.5 inches) wide; no top or bottom clearance spacing required. rms, noise as low as 15mV p-p. 0-5kΩ. 375 600 W 5 300 V 2

More information

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out SmartOnline 200-240V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out MODEL NUMBER: SU10KRT3/1X Highlights 10,000VA (10kVA)

More information

1.2 Intel Server Chassis SC5400BASE Summary

1.2 Intel Server Chassis SC5400BASE Summary Introduction Intel Server Chassis SC5400BASE Customization Panels Unpainted Rack Top Cover Slim Line CDROM/USB Floppy Kit Intel Server Chassis SC5400BRP 10-pack Branding / Customization Panels Unpainted

More information

Cisco MCS 7825-I1 Unified CallManager Appliance

Cisco MCS 7825-I1 Unified CallManager Appliance Data Sheet Cisco MCS 7825-I1 Unified CallManager Appliance THIS PRODUCT IS NO LONGER BEING SOLD AND MIGHT NOT BE SUPPORTED. READ THE END-OF-LIFE NOTICE TO LEARN ABOUT POTENTIAL REPLACEMENT PRODUCTS AND

More information

RADCOM s Platform Specifications. Valid from Version 7.10

RADCOM s Platform Specifications. Valid from Version 7.10 Valid from Version 7.10 RADCOM Ltd., November 2006 IP Notices: 2006 RADCOM Ltd. All rights reserved. RADCOM is a trademark of RADCOM Ltd. in Israel and/or other countries. Microsoft Windows and Microsoft

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

1073N. Channel Amplifier. User Manual Issue 1.3

1073N. Channel Amplifier. User Manual Issue 1.3 1073N Channel Amplifier User Manual 527-404 Health & Safety Notice For your own safety and for the protection of others, please observe the following safety precautions: Read these instructions. Keep these

More information

Product Overview. Cisco ME 6524 Ethernet Switch (ME-C6524GS-8S) CHAPTER

Product Overview. Cisco ME 6524 Ethernet Switch (ME-C6524GS-8S) CHAPTER 2 7 CHAPTER This chapter describes the Cisco ME 00 series Ethernet switches and contains these sections: Cisco ME 2 Ethernet Switch (ME-C2GS-8S), page - Cisco ME 2 Ethernet Switch (ME-C2GT-8S), page -7

More information

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1582-45L Data Switch September 2010, Rev A REMOTE LOCAL SWITCH STATUS SELECT REMOTE LOCAL LOCAL SELECT CHANNEL SELECT POWER MODEL 1582 SWITCH CROSS TECHNOLOGIES, INC. Data, drawings,

More information

Cisco D9036 Modular Encoding Platform

Cisco D9036 Modular Encoding Platform Cisco D9036 Modular Encoding Platform Product Overview The Cisco D9036 Modular Encoding Platform provides multi-resolution, multi-format encoding for applications requiring high levels of video quality.

More information

CT-400 FEATURES. A Price/Performance Breakthrough for VXI Mainframes. Modular Power Supply Assembly. Over 1100 Watts of Usable Power

CT-400 FEATURES. A Price/Performance Breakthrough for VXI Mainframes. Modular Power Supply Assembly. Over 1100 Watts of Usable Power data sheet CT-400 Modular 13-slot C-size VXIbus Mainframe FEATURES A Price/Performance Breakthrough for VXI Mainframes Modular Power Supply Assembly Over 1100 Watts of Usable Power Highly Efficient, Quiet

More information

Chassis-based Media Converters

Chassis-based Media Converters Media Converters with Individual Metal Case Housing. DMC-615SC DMC-1002 Management Module DMC-1000 Chassis Chassis-based Media Converters System Overview The Chassis-based Media Converters include a number

More information

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA The SR series on line double conversion UPS with full time Digital Signal Processor control technology is the perfect solution for mission critical users who demand high reliability, availability and performance

More information

EthernetConnect and IP/Analog Fiber Accessories POWER SUPPLIES, RACK CHASSIS WITH INTERNAL POWER SUPPLY

EthernetConnect and IP/Analog Fiber Accessories POWER SUPPLIES, RACK CHASSIS WITH INTERNAL POWER SUPPLY PRODUCT SPECIFICATION transmission and power EthernetConnect and IP/Analog Fiber Accessories POWER SUPPLIES, RACK CHASSIS WITH INTERNAL POWER SUPPLY Product Offerings USRACK/EURACK: Rack Chassis with Internal

More information

Tracewell S42 for VXS/V64x

Tracewell S42 for VXS/V64x Data Sheet 567 Enterprise Drive Westerville, OH 43081 1.800.848.4525 phone 614.846.6175 fax 614.846.4450 www.tracewellsystems.com Tracewell S42 for VXS/V64x Ultra-lightweight Rugged Performance System

More information

Optimux-34 Fiber Optic Multiplexer

Optimux-34 Fiber Optic Multiplexer Data Sheet Optimux-34 Multiple E1, Ethernet, or High-speed Data over E3 or Fiber, up to 110 km (68 miles) Up to 16 E1 links, high-speed data, and Ethernet traffic multiplexed into one E3 copper or fiber

More information

6220 Ethernet-Based Voltage Measurement Module

6220 Ethernet-Based Voltage Measurement Module 6220 Ethernet-Based Voltage Measurement Module Features 12 voltage inputs 16-bit, 100-kHz per channel sample rate ±10V input range Eight digital I/O Simultaneous sampling BNC connectors Multiple trigger

More information

DPA 7000 PATENTS PENDING TELEPHONE AND LINE ANALYZER

DPA 7000 PATENTS PENDING TELEPHONE AND LINE ANALYZER TM TELEPHONE AND LINE ANALYZER DPA 7000 PATENTS PENDING TELEPHONE AND LINE ANALYZER PATENTS PENDING The TALAN represents state-of-the-art capability to rapidly and reliably detect and locate illicit tampering

More information

Chapter 2 BladeStation Enclosure

Chapter 2 BladeStation Enclosure Chapter 2 BladeStation Enclosure Cubix BladeStation is an enclosure that provides power and cooling to multiple Cubix Blade Servers. It consists of a steel case, a mid-plane, an Input / Output (I / O)

More information

RF0250 RF1100 RF1200 RF1300 RF1600

RF0250 RF1100 RF1200 RF1300 RF1600 RF0250 RF1100 RF1200 RF1300 RF1600 Power Amplifier User Manual Issue 5 September 2017 LAPLACE INSTRUMENTS LTD Page 1 Page 2 Caution This unit produces high RF-power. It must be assured that maximum radiation

More information

LFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

LFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00 Features 4 x 2 x 1 Inches Form factor 225 Watts with Forced Air Cooling Approval to EN60601 3 rd Edition Efficiencies upto 94% -40 to 70 degree operating temperature* Dual fusing 12V / 0.5A Fan Output,

More information

Installing and Configuring Rialto Analytic Appliances

Installing and Configuring Rialto Analytic Appliances Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation

More information

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions... Table of Contents Quick Install Guide page 1 EN English Table of Contents 1. Introduction... 2 1.1 Safety... 2 1.2 Rack System Precautions... 2-3 1.3 ESD Precautions... 3... 3 1... 3 2 Fitting PSU s...

More information

QUALITROL QTMS Transformer Monitoring System

QUALITROL QTMS Transformer Monitoring System QUALITROL QTMS Transformer System Providing the Missing Piece in Your Condition Based Platform Modular design; full customization of monitoring parameters to meet specification Reduce installation and

More information

Installation Job Aid for Ethernet Routing Switch 5900 Series

Installation Job Aid for Ethernet Routing Switch 5900 Series Installation Job Aid for Ethernet Routing Switch 5900 Series Notices NN47211-301 Issue 05.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

3/4 U CPCI Serial Case System

3/4 U CPCI Serial Case System 3/4 U CPCI Serial Case System User s Manual Product Number: 4579-634 Doc-No: 6397-345_R.0 October 05 R.0 October 05 Initial Release Impressum: Schroff GmbH Langenalber Str. 96-00 75334 Straubenhardt, Germany

More information

Installation Job Aid for VSP 4850GTS

Installation Job Aid for VSP 4850GTS Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe

More information

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply Sorensen DLM 600 Series Half Rack Programmable DC Power Supply High Power Density: 600 watts in 1U (1.75 inches) high, half rack (8.5 inches) wide; no top or bottom clearance spacing required. Near Linear

More information

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control 1. INTRODUCTION User Manual This family of efficient, upgraded SMPS with small form factor,

More information

Lightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide

Lightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide Lightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide 1800 19th Street / Bakersfield, CA 93301 / Tel: 661.716.7600 / Toll Free: 877.447.6244 / www.lightspeedsystems.com Table of Contents

More information

NVE40K Installation Guide

NVE40K Installation Guide NVE40K Installation Guide INFORMATION TO USER CAUTION RISK OF ELECTRIC SHOCK, DO NOT OPEN! CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE.

More information

Junos WebApp Secure 5.0 Hardware Guide

Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a

More information

Power Enclosure Components

Power Enclosure Components Power Enclosure Components HP BladeSystem p-class 1U Power Enclosure Exploded View Figure 1-5 HP BladeSystem p-class 1U power enclosure exploded view Illustrated Parts Catalog 20 HP BladeSystem p-class

More information

User Guide Ku Band Solid State Amplifiers - SSPA

User Guide Ku Band Solid State Amplifiers - SSPA User Guide Ku Band Solid State Amplifiers - SSPA Outdoor Band Solid State Amplifier System User Guide This section provides general information for the UPCOM TECHNOLOGIES line of Outdoor Solid State Amplifers

More information

SWITCH SOLUTIONS SWITCH MATRIX CATALOG ELECTROMECHANICAL MATRIX SOLID STATE MATRIX FIBER OPTIC MATRIX FULLY INTEGRATED SYSTEMS

SWITCH SOLUTIONS SWITCH MATRIX CATALOG ELECTROMECHANICAL MATRIX SOLID STATE MATRIX FIBER OPTIC MATRIX FULLY INTEGRATED SYSTEMS SWITCH MATRIX CATALOG SWITCH SOLUTIONS ELECTROMECHANICAL MATRIX SOLID STATE MATRIX FIBER OPTIC MATRIX FULLY INTEGRATED SYSTEMS OUR EXPERTISE, YOUR SWITCH SOLUTION SINCE 1945 Our Experience As the world

More information

RT4F-110V/25A RECTIFIER

RT4F-110V/25A RECTIFIER The RT4F-110V/25A is a hot-pluggable switched mode rectifier (SMR) module designed to provide up to 25A of output current into a 110V nominal system. Examples of such systems are 60 cells lead acid (136V

More information

Brochure. ION Multi-Service Integration Platform. Integrate. Optimize. Navigate. Transition Networks Brochure.

Brochure. ION Multi-Service Integration Platform. Integrate. Optimize. Navigate. Transition Networks Brochure. Brochure ION Multi-Service Integration Platform Integrate. Optimize. Navigate. Transition Networks Brochure The ION Platform Overview The ION Multi-Service Integration Platform offers first-rate solutions

More information

SINGLEstream Link Aggregation Tap (SS-100)

SINGLEstream Link Aggregation Tap (SS-100) SINGLEstream Link Aggregation Tap (SS-00) Optional 3-Unit Rack Mount Datacom Systems SINGLEstream 0/00 Link Aggregation Tap provides a superior solution for 4x7 monitoring of full-duplex Ethernet links.

More information

In-Series and Between-Series Adapters SMA

In-Series and Between-Series Adapters SMA Adapters SMA In-Series and Between-Series Adapters SMA If your choice of SMA Adapter is not shown in this section, please refer to the Table below to determine other possible locations. Should you not

More information

RF switch network. RFB 2000, RFC 2010 or 2020

RF switch network. RFB 2000, RFC 2010 or 2020 RFB 000, RFC 010 or 00 The can be configured to switch RF signals in a wide range of automatic test systems. Various switch configurations are available, connecting one input to either two or six outputs.

More information

Premium Online Series

Premium Online Series Premium Online Series UPS backup power systems backup protection with double conversion that isolates and conditions output power for clean, consistent, reliable power features: Permanent connection to

More information

ECHO AIO TEST INTERFACE

ECHO AIO TEST INTERFACE ECHO AIO TEST INTERFACE Product Manual June 2017 2017 Echo Digital Audio Contents INTRODUCTION... 2 AIO CONFIGURATIONS... 3 AIO DIMENSIONS AND WEIGHT (ALL MODELS):... 5 SAFETY INSTRUCTIONS... 6 INSTALLATION...

More information

AMU1-CHD+MK2 AUDIO MONITORING UNIT

AMU1-CHD+MK2 AUDIO MONITORING UNIT AMU1-CHD+MK2 AUDIO MONITORING UNIT Handbook TSL Products Units 1-2, First Avenue, Globe Park, Marlow, Bucks, SL7 1YA Telephone +44 (0)1628 564610 This Page is Blank SAFETY Installation. Unless otherwise

More information