1 Reliability in Surge Protection Wind Turbine installation

2 Windmill generators are equipment especially exposed to the risks of lightning and transitory overvoltages : due to their height and to their location on high or/and isolated spots, the probability of direct lightning strikes is much higher than for traditional installations. In case of lightning strike, windmill generators are usually designed to drain the lightning current in a safe way, but internal equipments (generator, management, control/commands, sensors.) will be submitted to transient surges induced by the phenomena: in order to ensure the necessary operation and to improve the windmill generator s global reliability, surge protectors are necessary and will have to be installed at the entrance of the various sensitive equipments. 7 Obstruction Lighting Datalines LED OBSTA FLASH DLU / DLA Datalines SPD 90V 8 230V / 00V 2 DU33S-000G/WD 3-phase Type 2 SPD - 90V DS3S-90/WD AC Type 2 SPD DS230-8DC Type 2 SPD 8DC DS20-230/G 0/G Single-phase Type 2 SPD DS3S-00 3-phase Type 2 SPD for 00V 3 DS23VG-90 3-phase Type SPD 90V 3

3 Surge protector and obstruction lighting for wind turbines Obstruction lighting 7 Sensor Control cabinet (Blade management) Control cabinet (control pitch) Motor «Pitch System» connection Rotor Control cabinet (nacelle direction / Yaw) Sensor Motor Stator connection 2 Power cabinet 8 Energy supply cabinet «Yaw system» Monitoring cabinet Weather sensor link Surge protectors for windmill generators are divided in different categories : Surge protectors for AC network that may receive a part of the lighting current : Type surge protectors (eg : DS23VG-90 General power supply cable 3-phase 00V supply Dataline Surge protectors for AC network submitted to induced or coupled surges: Type 2 surge protectors (eg: DS3S-00, DU33S-000/WD.) Surge protectors for communication network or sensor (eg. DLU or DLA range) Transformer Nacelle monitoring system 3 Main power supply Outdoor communication link NB : Typical configuration that may vary according to the windturbine manufacturer and the type of installations.

4 3-phase surge protectors Citel range DU33S-000/WD/G DS3S-90 DS3S-00 Network 3-phase + Neutral 00/90 V 3-phase 00/90 V 3-phase 00 V DU33S-000/WD/G SPD type Type 2 Type 2 Type 2 Nominal discharge current ka 20 ka 20 ka Maximal discharge current 00 ka 0 ka 0 ka Screw terminal 3 mm² max Screw terminal 3 mm² max Screw terminal 2 mm² max DS3S-90 Mounting DIN Rail DIN Rail DIN Rail End of life disconnection + Indicator disconnection + Indicator disconnection + Indicator Remote signalling Yes Yes Yes Dimensions (width) mm mm mm DS3S-00 Référence CITEL Network DS23VG-90 3-phase 00/90 V SPD type Type +2+3 DS23VG-90 Single-phase surge protector Nominal discharge current Maximum lighting current 0/30µs Maximal discharge current Mounting End of life Remote signalling Dimensions (width) 30 ka 7 ka 00 ka Screw terminal 3 mm² max DIN Rail disconnection + Indicator Yes 270 mm Référence CITEL Single-phase DS20-230/G 230 V SPD type Type 2 DS20-230/G Nominal discharge current Maximal discharge current Mounting End of life Remote signalling Dimensions (width) 20 ka 0 ka Screw terminal 2 mm² max DIN Rail disconnection + Indicator Option (DS20S-230/G) 8 mm

5 8V DC surge protector CITEL range DC power supply DS230-8DC 8V DC SPD type Type 2 DS230-8DC Nominal discharge current Maximal discharge current Mounting End of life Remote signalling Dimensions (width) ka 30 ka Screw terminal 0 mm² max DIN Rail SPD disconnection + Indicator On Option (DS230S-8DC) 8 mm Dataline SPD DLA DLU CITEL range DLA range DLU range Format Pluggable SPD Monoblock SPD Typical application Datalines Datalines Configuration pair + shield pair + shield Nominal line voltage 2 V, 2 V, 0 V 2 V, 2 V, 0 V Maximum line current 300 ma 300 ma Nominal discharge current ka ka Maximal discharge current 20 ka 20 ka Mounting DIN Rail DIN rail OBSTA Obstruction lighting OBSTA P/N Main characteristics Power supply Max. consumption 3720 White only 8 Vdc < 7 W 372 Red only 8 Vdc < 2 W 3722 Bi color 8 Vdc < 7 W 3723 White only 20/230 Vac < 7 W 372 Red only 20/230 Vac < 2 W 372 Bi color 20/230 Vac < 7 W Main characteristics Luminous output Color Beam spread Day Night Day Night Vertical Horizontal Flashes per minute Red only 2000 Cd Red White only Cd 2000 Cd White White Bi color Cd 2000 Cd White Red

6 Reliability in Surge Protection BR30802 Document could be modified without notice Head office CITEL-2CP 2, rue Troyon 923 Sèvres CEDEX France Tél. : Fax : contact@citel.fr Web : Factory CITEL-2CP 3 impasse de la Blanchisserie BP 02 Reims CEDEX France Tél. : Fax : contact@citel.fr Germany CITEL Electronics GmbH Alleestrasse, Tor D-793 Bochum Germany Tél. : Fax : info@citel.de Web : USA CITEL Inc. 008 USA Today Way Miramar, FL3302 USA Tel : (9) Fax : (9) info@citel.us Web site : China Shanghai Citel Electronics Co,Ltd 99 Kang Yi Road Kang Qiao Industrial Zone 203 Pudong, Shanghai P.R. CHINA Tél. : Fax : shanghai@citel2cp.com Web : Czech Republic CITEL ELECTRONICS Kundratka 7A 8000 Praha Czech Republic Tél. : Fax : citel@citel.cz Web : Russia CITEL RUSSIA Bolchaya Pochtovaya Str 2B/ RU-0082 Moscow Russia Tél. : info@citel.ru Web : India CITEL INDIA A - - South Extension, Part-II New Delhi India Tél. : indiacitel@gmail.com Web :

Reliability in Surge Protection. LED lighting.

Reliability in Surge Protection. LED lighting. Reliability in Surge Protection LED lighting www.citel.fr LED Lighting systems Installation of Surge Protectors MLP MSB6 Single-phase compact AC surge protector for architectural outdoor lighting Single-phase

More information

Reliability in Surge Protection. Surge Protection. for Security Systems.

Reliability in Surge Protection. Surge Protection. for Security Systems. Reliability in Surge Protection Surge Protection for Security Systems www.citel.us The components used in outdoor security systems are highly susceptible to lightning surges. If your security systems are

More information

Reliability in Surge Protection. for Security Systems

Reliability in Surge Protection. for Security Systems Reliability in Surge Protection SURGE PROTECTION for Security Systems CITEL - 2 rue Troyon - 92316 Sèvres Cedex - France Téléphone : +33 1 41 23 50 23 - contact@citel2cp.com - www.citel2cp.com Almost all

More information

Reliability in Surge Protection. LED Lighting Systems.

Reliability in Surge Protection. LED Lighting Systems. Reliability in Surge Protection for LED Lighting Systems www.citel.us LED Lighting Systems Installation of Surge Protectors Surge Protective Devices for LED Outdoor Lighting In recent years, there has

More information

Intelligent Transportation Systems

Intelligent Transportation Systems Reliability in Surge Protection for Intelligent Transportation Systems www.citel.us Surge Protective evices for Traffic ontrol Message isplay PTZ amera Traffic Sensors Traffic light Gate utomatic Payment

More information

Reliability in Surge Protection. Surge Protection. AC & DC Power Photovoltaic Coaxial Telecom Gas Discharge Tubes.

Reliability in Surge Protection. Surge Protection. AC & DC Power Photovoltaic Coaxial Telecom Gas Discharge Tubes. Reliability in Surge Protection Surge Protection AC & DC Power Photovoltaic Coaxial Telecom Gas Discharge Tubes www.citel.us CITEL Established in 1937, CITEL is the global leader in the development and

More information

Reliability in Surge Protection. Photovoltaic Systems.

Reliability in Surge Protection. Photovoltaic Systems. Reliability in Surge Protection Photovoltaic Systems www.citelcp.com Roof top installations For low power PV applications, i.e. residences and small offices, it is necessary to consider surge protecting

More information

SURGE PROTECTOR. lighting. for.

SURGE PROTECTOR. lighting. for. SURGE PROTECTOR for lighting www.citel2cp.com LED Lighting systems Installation of Surge Protectors MLP MSB6 Single-phase compact AC surge protector for architectural outdoor lighting Single-phase AC surge

More information

Reliability in Surge Protection. Surge Protection. AC & DC Power Photovoltaic Coaxial Telecom Gas Discharge Tubes.

Reliability in Surge Protection. Surge Protection. AC & DC Power Photovoltaic Coaxial Telecom Gas Discharge Tubes. Reliability in Surge Protection Surge Protection AC & DC Power Photovoltaic Coaxial Telecom Gas Discharge Tubes www.citel.us CITEL Established in 1937, CITEL is the global leader in the development and

More information

M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS

M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS G1 Outdoor Surge Protector for AC/Traction network VP range Dimensions (in mm) 19 M8 44 73 diam. 47 6 mm² Electrical

More information

Lightning & Surge Protection for Wind Turbine Systems

Lightning & Surge Protection for Wind Turbine Systems Lightning & Surge Protection for Wind Turbine Systems Product Selection Guide Table of Contents Technologies for Wind Turbine Protection 3 Protective Device Recommendations 4 Class I Strikesorb Surge Protection

More information

Surge protection for closed-circuit television systems (CCTV) Guide for support in planning and installation. Building Connections

Surge protection for closed-circuit television systems (CCTV) Guide for support in planning and installation. Building Connections Surge protection for closed-circuit television systems (CCTV) Guide for support in planning and installation Building Connections Application Camera systems are used to monitor rooms, buildings and outdoor

More information

Surge Protection Devices Ex9UE2

Surge Protection Devices Ex9UE2 Surge Protection Devices Ex9UE2 Surge Protection Devices Type 2 (Class II, T2, C) Tested according to EN 61643-11 Maximum continuous operational voltage U c from 275 V up to 440 V AC Versions with 1+0,

More information

Surge Protection for Surveillance Systems

Surge Protection for Surveillance Systems Surge Protection for Surveillance Systems 1-in-1 Protection for Network Cameras 2-in-1 Protection for Power and Audio/Video Signals 3-in-1 Protection for Power, Audio/Video and PTZ Control Signals Application:

More information

Surge & Filter Protection Addressing your industrial power quality needs.

Surge & Filter Protection Addressing your industrial power quality needs. Surge & Filter Protection Addressing your industrial power quality needs. BULLETIN 983 INTRODUCING SURGE & FILTER PROTECTION SURGE & FILTER PROTECTION Rockwell Automation is pleased to introduce the Bulletin

More information

DBPApplication. PD Devices Ltd. Unit 1, Old Station Yard, South Brent, Devon. TQ10 9AL (0)

DBPApplication. PD Devices Ltd. Unit 1, Old Station Yard, South Brent, Devon. TQ10 9AL (0) DBP Series Data Protection Designed for business and industrial applications, these products provide protection for local area networks, CCTV/video equipment, computer serial communication interfaces and

More information

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany Lightning and Surge Protection of Photovoltaic Installations 1 Lightning and Surge Protection for PV Installations 2 Safeguard from Risks Ups, that was the insurance policy of my house!! 3 Why Lightning

More information

Top to Bottom Protection & Monitoring Solutions

Top to Bottom Protection & Monitoring Solutions Top to Bottom Protection & Monitoring Solutions It s our business to help yours thrive. Top Controller & Converter Generator Pitch Controller Data and DC Power Supply Lines Customized Solutions & Special

More information

AI561 Analog Input Module

AI561 Analog Input Module Ordering Data DATA SHEET AI561 Analog Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R1101 AI561, analog input module, 4 AI, U/I 1TNE 968 901 R3101 1TNE 968

More information

Lightning Current Equipotential Bonding SPDs

Lightning Current Equipotential Bonding SPDs Lightning Current Equipotential Bonding SPDs Introduction Furse is a world leader in the design, manufacture, and supply of earthing and lightning protection systems. Over 100 years of experience makes

More information

Lightning and surge protection for wind turbines

Lightning and surge protection for wind turbines Lightning and surge protection for wind turbines Information from DEHN Due to their vast exposed surface and height, wind turbines are vulnerable to direct lightning strikes. Since the risk of lightning

More information

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection CONTA-ELECTRONICS CONTA-PROTECT overvoltage protection When choosing the correct device for overvoltage protection, it is important to consider the regulations VDE 110-1, IEC 61643-1, EN 61643-11 and VDE

More information

DI572 Digital Input Module

DI572 Digital Input Module Ordering Data DATA SHEET DI572 Digital Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 230 500 R0000 1TNE 968 901 R3101 1TNE 968 901 R3102 1TNE 968 901 R3103 1TNE 968

More information

Autoprotected Surge Arresters New OVR Plus range

Autoprotected Surge Arresters New OVR Plus range Autoprotected Surge Arresters New OVR Plus range A complete solution with the OVR PLUS range Thanks to its continuous innovation on surge protection, ABB improves constantly its offer by launching on the

More information

Overvoltage Protection

Overvoltage Protection Overvoltage Protection OVR Range FRSOX 0100 03 GB ABB Lightning Protection Group 1 Main causes of transient overvoltages The solution: ABB OVR Surge Protective Device Range Lightning strike A lightning

More information

DI561 Digital Input Module

DI561 Digital Input Module Ordering Data DATA SHEET DI561 Digital Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2101 1TNE 968 901 R3101 1TNE 968 901 R3103 1TNE 968 901 R3105 DI561, digital

More information

White Paper Surge Protective Devices in Automatic Transfer Switches

White Paper Surge Protective Devices in Automatic Transfer Switches White Paper Surge Protective Devices in Automatic Transfer Switches Standby power systems provide emergency power, legally required power, or optional standby AC power during utility outages. Standby AC

More information

Surge Protection & Monitoring Solutions for Photovoltaic Systems

Surge Protection & Monitoring Solutions for Photovoltaic Systems Surge Protection & Monitoring Solutions for Photovoltaic Systems Raycap Products Provide the Ultimate Lightning Surge Protection for Photovoltaic Systems The remote locations, exposed surface areas and

More information

Commercial and Industrial LV Power Protection

Commercial and Industrial LV Power Protection Commercial and Industrial LV Power Protection Surge protection in Australia Tristan King Contents Introduction... 1 What is a Surge?... 1 Surge Protection Device... 2 Surge Protection Categories... 2 Category

More information

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects of transient over voltages caused by

More information

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards Extract from the online catalog SFP 1-5/120AC Order No.: 2920667 Device surge protection filter to limit powerful surge voltages, mounting on NS 35. Commercial data EAN 4046356158558 Pack 1 pcs. Customs

More information

PHOTOVOLTAIC PLANTS Comprehensive lightning protection

PHOTOVOLTAIC PLANTS Comprehensive lightning protection PHOTOVOLTAIC PLANTS Comprehensive lightning protection 1. Introduction Photovoltaic (PV) plants are composed of many panels supported on large metal structures, located in open areas and normally highly

More information

AO523 Analog Input Module

AO523 Analog Input Module Ordering Data DATA SHEET AO523 Analog Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 250 200 R0001 1SAP 450 200 R0001 AO523, analog output module, 16 AO, U/I, 12 bits

More information

FP-PS-4. Features. Installation

FP-PS-4. Features. Installation OPERATING INSTRUCTIONS FP-PS-4 FieldPoint Power Supply These operating instructions describe the installation, features, and characteristics of the FP-PS-4. Features The FP-PS-4 is a FieldPoint power supply

More information

DC561, digital input/output module,

DC561, digital input/output module, Ordering Data DATA SHEET DC561 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2001 DC561, digital input/output module, 16 configurable inputs/outputs,

More information

Advancing Serial-to-Ethernet Technology

Advancing Serial-to-Ethernet Technology Advancing Serial-to-Ethernet Technology As a market leader, Moxa continues to lead the development of reliable, convenient, and efficient serial-to-ethernet technology for today s growing networking challenges.

More information

Peak/Valley Hold Unit (PVHU) User Manual V3.00

Peak/Valley Hold Unit (PVHU) User Manual V3.00 Peak/Valley Hold Unit (PVHU) User Manual V3.00 Part Number: DO-UM0084/30/UE Applies to Firmware Version: V3.01 Reference: Peak_Valley Hold Unit (PVHU) User Manual.docx Date: 30 May 2016 Version: 3.00 Peak/Valley

More information

AC panel transient voltage surge suppressors

AC panel transient voltage surge suppressors Instruction sheet MTL surge protection INS 801-481 Rev G ZoneSentinel range AC panel transient voltage surge suppressors Introduction This document explains how to install the ZoneSentinel range of AC

More information

DX561 Digital Input/Output Module

DX561 Digital Input/Output Module Ordering Data DATA SHEET DX561 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2301 1TNE 968 901 R3101 DX561, digital input/output module, 8 DI

More information

TU531, TU532 Terminal Unit

TU531, TU532 Terminal Unit Ordering Data DATA SHEET TU531, TU532 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 217 200 R0001 1SAP 217 000 R0001 1SAP 417 000 R0001 TU531, terminal unit, 230 VAC,

More information

Digital Frequency Divider INSTRUCTION MANUAL CONTENTS. 1. Working Principle Installation Setting Up Technical Data 4.

Digital Frequency Divider INSTRUCTION MANUAL CONTENTS. 1. Working Principle Installation Setting Up Technical Data 4. Digital Frequency Divider INSTRUCTION MANUAL CONTENTS 1. Working Principle 2 2. Installation 2 3. Setting Up 3 4. Technical Data 4 Code: 189/1a 1 WORKING PRINCIPLE The DFD has been designed to generate

More information

DC562, digital input/output module,

DC562, digital input/output module, Ordering Data DATA SHEET DC562 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 231 900 R0000 1TNE 968 901 R3101 1TNE 968 901 R3102 1TNE 968 901 R3103 1TNE

More information

TT-2-PE-M-24DC. Extract from the online catalog. Order No.:

TT-2-PE-M-24DC. Extract from the online catalog. Order No.: Extract from the online catalog TT-2-PE-M-24DC Order No.: 2920641 Modular terminal block with two-stage surge protection for one operated floating double conductor, disconnect knife on both signal paths,

More information

DEHN tests and analyses DEHN Test Centre.

DEHN tests and analyses DEHN Test Centre. DEHN tests and analyses DEHN Test Centre www.dehn-international.com 2 Powerful: Lightning current tests up to 400 ka (10/350 µs) DEHN protects. Our task is to protect persons, buildings, installations

More information

SURGE PROTECTION OPTION

SURGE PROTECTION OPTION Reliable Continuous Energy PV FOR TELECOM Installation Guide Gen 4 PVT Panels ENHANCED SURGE PROTECTION OPTION Manual Rev 4.4 Apollo Solar -- Gen 4 PVT Enhanced Surge Protection Option Page - 1 - IMPORTANT

More information

US Catalog March Surge protective devices (SPDs) UL range

US Catalog March Surge protective devices (SPDs) UL range US Catalog March 017 Surge protective devices (SPDs) UL range Surge protective devices (SPDs) UL range Introduction 1 1 OVR surge protective devices Joslyn surge protective devices Marketing tools 4 US

More information

SPM Series. Plug-in Surge Protection

SPM Series. Plug-in Surge Protection SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects

More information

Surge Protection Devices and Surge Protection Kit

Surge Protection Devices and Surge Protection Kit Surge and Surge Kit SPD s protect electrical and electronic equipment against transients, originating from lightning, switching of transformers, lighting and motors 3. Main protection - class 3 To cut-down

More information

Monitoring products K8 SERIES. C o m p l e t e r a n g e i n m m w i d e h o u s i n g. Advanced Industrial Automation

Monitoring products K8 SERIES. C o m p l e t e r a n g e i n m m w i d e h o u s i n g. Advanced Industrial Automation Monitoring products K8 SERIES C o m p l e t e r a n g e i n 2 2. 5 m m w i d e h o u s i n g Advanced Industrial Automation Omron s K8 series of monitoring products provides you with first-class quality

More information

AO561 Analog Output Module

AO561 Analog Output Module Ordering Data DATA SHEET AO561 Analog Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R1201 AO561, analog output module, 2 AO, U/I 1TNE 968 901 R3102 Terminal

More information

Industrial motor controller for brushed DC motors 24 VDC

Industrial motor controller for brushed DC motors 24 VDC Industrial motor controller for brushed DC motors 24 VDC Design for output currents up to 6 A Control with the following functions: - reversal of direction of rotation - overcurrent shutdown - overcurrent

More information

Company Profile Surge Protective Devices

Company Profile Surge Protective Devices Company Profile Surge Protective Devices Who we are What we do SALTEK is a leading Czech based company specialising in the development and production of Surge Protective Devices. SALTEK offers a complete

More information

AC Surge Protection Devices

AC Surge Protection Devices AC Surge Protection Devices FLEXIBLE, INNOVATIVE SOLUTIONS FOR INFOCOM SYSTEM PROTECTION pioneers in surge protection Joslyn is recognized worldwide as the pioneer in the design, development and manufacture

More information

Lightning and Surge Arresters

Lightning and Surge Arresters Lightning and Surge Arresters 5/4 Product overview 5/5 Lightning arresters, requirement category I (B) 5/6 Combined arresters, requirement category I (B) and II (C) 5/7 Single-pole surge arrester, requirement

More information

TF501, TF521 Terminal Bases

TF501, TF521 Terminal Bases Ordering Data DATA SHEET TF501, TF521 Terminal Bases 1 Ordering Data Part No. Scope of delivery Product life cycle status 1SAP 117 000 R0271 1SAP 317 000 R0271 1SAP 117 200 R0271 1SAP 317 200 R0271 TF501-CMS,

More information

Surge Protective Devices OVR Series - Enclosed SPD Mining and Aggregates

Surge Protective Devices OVR Series - Enclosed SPD Mining and Aggregates Application note Surge Protective Devices OVR Series - Enclosed SPD Mining and Aggregates ABB OVR Series Electrical surges can be a real downer. Sherwood Construction's stone quarry in Tulsa, Oklahoma,

More information

Increased Safety for Switchgear Cabinets CI Arresters with Integrated Backup Fuse

Increased Safety for Switchgear Cabinets CI Arresters with Integrated Backup Fuse Increased Safety for Switchgear Cabinets CI Arresters with Backup Fuse www.dehn-international.com 1 fuse 1 2 fuse monitoring 2 3 Considerable space saving 3 Innovative solution to save space in the switchgear

More information

SPM Series Plug-in Surge Protection

SPM Series Plug-in Surge Protection SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects

More information

PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment

PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment NTSA has developed the ultimate solution for protecting

More information

Surge Protective Device

Surge Protective Device Surge Protective Device LED Light / Machine protection SPD Class 2 LT-C34G801W General Information LT-C and LT-HC series Surge Protective Devices are for protection of indirect lightning. They are designed

More information

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version Ordering Data DATA SHEET TU520 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 214 400 R0001 1SAP 414 400 R0001 TU520-ETH, PROFINET I/O terminal unit, 24 VDC, spring

More information

BLITZDUCTOR XTU Universal lightning current / surge arrester

BLITZDUCTOR XTU Universal lightning current / surge arrester Pluggable DIN Rail Mounted SPDs Combined lightning current and surge arrester Max. discharge capacity for balanced data interfaces Capable of carrying lightning currents up to 10 ka (10/50 μs) For installation

More information

2U Congestion Alert Rack Insert for UK

2U Congestion Alert Rack Insert for UK 2U Congestion Alert Rack Insert for UK 2U Congestion Alert Rack Insert for UK The 2U congestion alert rack insert comes fully assembled, wired and ready to be installed in a rack. The rack provides communications,

More information

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.:

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.: Extract from the online catalog PT 2X2-HF-24 DC-ST Order No.: 2839729 The illustration shows the version PT 2x2-HF-12 DC-ST Protective plug PT with HF protective circuit for two 2-core floating signal

More information

BS th Edition wiring regulations Furse overview

BS th Edition wiring regulations Furse overview BS 7671 18th Edition wiring regulations Furse overview Transient overvoltage protection TRANSIENT OVERVOLTAGE PROTECTION - RISK ASSESSMENT TO BS 7671 Furse electronic systems protection Enhanced solutions

More information

NTS-protect. Description of GPS antenna and NTS time server connection via system lightning protector system /NTS-3000, NTS-4000, NTS-5000/

NTS-protect. Description of GPS antenna and NTS time server connection via system lightning protector system /NTS-3000, NTS-4000, NTS-5000/ NTS-protect Description of GPS antenna and NTS time server connection via system lightning protector system /NTS-3000, NTS-4000, NTS-5000/ SAFETY INSTRUCTIONS! This are the important Safety Instructions

More information

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14 Leutron Lightningand Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices Seite 0 von14 Novelties 2003 Combi Surge Protectors Leutron GmbH, 70771 Leinfelden-Echterdingen, Deutschland

More information

16 way 19 1½U enclosure with rear cable management tray NPGZM-16-NJ. ½U high front mounting cable management tray

16 way 19 1½U enclosure with rear cable management tray NPGZM-16-NJ. ½U high front mounting cable management tray Features: Connects 75 ohm coaxial and 120 ohm twisted pair cabling systems Supports all G.703 data rates up to 34 Mbps Snap-in modules are easy to install and maintain Field expandable and upgradable Various

More information

DSP 600 SERIES Distribution Surge Protector

DSP 600 SERIES Distribution Surge Protector B O W T H O R P E T V S S DSP 600 SERIES Distribution Surge Protector DSP1/600 DSP1A/600 DSP3/600 DSP3A/600 DSP1N/600 DSP3N/600 DSP1L/600 DSP3L/600 Installation Instructions Description and Operation The

More information

PT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.:

PT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.: Extract from the online catalog PT 5-HF- 5 DC-ST Order No.: 2838762 The illustration shows variant PT 5-HF-12 DC-ST Protective plug PT with HF protective circuit for 4 signal wires. Nominal voltage: 5

More information

Lightning and Surge Protection for PV Systems

Lightning and Surge Protection for PV Systems Lightning and Surge Protection for PV Systems Application Note (AU) Phillip Tompson Introduction Like all electrical equipment photovoltaic systems can be damaged by both direct and indirect lightning

More information

PRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters

PRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters Type 1 and 2 LV surge s The Type 1 range of surge s meets the normative withstand capability of wave type 10/350 μs (8/20 μs for Type 2 surge s). It is suitable for use with, TN-C and 230 V IT earthing

More information

PT 3-PB-ST. Extract from the online catalog. Order No.:

PT 3-PB-ST. Extract from the online catalog. Order No.: Extract from the online catalog PT 3-PB-ST Order No.: 2858030 Surge protection plug for the base element, normal mode voltage coarse and fine protection for two floating signal wires in IT, common mode

More information

Electronic timer CT-ERD.12

Electronic timer CT-ERD.12 2CDC 251 092 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied

More information

VAL-CP-1S-175. Extract from the online catalog. Order No.:

VAL-CP-1S-175. Extract from the online catalog. Order No.: Extract from the online catalog VAL-CP-1S-175 Order No.: 2859479 Pluggable type 2 arrester (surge arrester) for 1-phase current supply networks with separate N and PE (3-conductor system: L1, N, PE), with

More information

TM258LD42DT4L compact base M I/O - 24 V DC

TM258LD42DT4L compact base M I/O - 24 V DC Characteristics compact base M258-42 + 4 I/O - 24 V DC Main Range of product Product or component type Product specific application Discrete I/O number 42 Analogue input number 4 Discrete output number

More information

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO Characteristics compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO Main Range of product Product or component type Complementary Enclosure material Colour Input/Output number

More information

TT-2-PE- 24DC. Extract from the online catalog. Order No.:

TT-2-PE- 24DC. Extract from the online catalog. Order No.: Extract from the online catalog TT-2-PE- 24DC Order No.: 2838186 Modular terminal block with three-stage surge protection for a floating double conductor, separate ground connection, nominal voltage: 24

More information

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.: Extract from the online catalog TT-ST-M-2-PE-24DC Order No.: 2858904 TERMITRAB, spring-cage modular terminal block with integrated surge protection and disconnect knives, for assembly on NS 35/7.5, voltage

More information

Industrial motor controller for brushed DC motors 24 VDC

Industrial motor controller for brushed DC motors 24 VDC Industrial motor controller for brushed DC motors 24 VDC Design for output currents up to 6 A Control with the following functions: - reversal of direction of rotation - overcurrent shutdown depends on

More information

External level devices for conductive point level switch

External level devices for conductive point level switch SENSORS FOR FOOD AND BIOPHARMA. Product Information VNV-2, ZNV-2 CONTROLS External level devices for conductive point level switch Application/Specified usage Point level detection of aqueous, conductive

More information

VAL-CP-3S-350. Extract from the online catalog. Order No.:

VAL-CP-3S-350. Extract from the online catalog. Order No.: Extract from the online catalog VAL-CP-3S-350 Order No.: 2859521 Commercial data EAN 4017918977610 Pack 1 Pcs. Customs tariff 85363030 Weight/Piece 388.83 g Product key J020 Catalog page information Page

More information

Click Desktop Kit. Click Desktop Kit

Click Desktop Kit. Click Desktop Kit Click Desktop Kit Click Desktop Kit The Click Desktop Kit is a desktop-mounted set that gives you the building blocks necessary to work with your Click modules at your computer, whether you re testing

More information

PT 2X2-24DC-ST. Extract from the online catalog. Order No.:

PT 2X2-24DC-ST. Extract from the online catalog. Order No.: Extract from the online catalog PT 2X2-24DC-ST Order No.: 2838228 The illustration shows version PT 2x2-5DC-ST Protective plug PT with protective circuit for two 2-core floating signal circuits. Nominal

More information

AX521 Analog Input/Output Module

AX521 Analog Input/Output Module Ordering Data DATA SHEET AX521 Analog Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 250 100 R0001 1SAP 450 100 R0001 AX521, analog input/output module, 4 AI,

More information

TM258LD42DT4L compact base M I/O - 24 V DC

TM258LD42DT4L compact base M I/O - 24 V DC Characteristics compact base M258-42 + 4 I/O - 24 V DC Main Range of product Product or component type Product specific application - Discrete I/O number 42 Analogue input number 4 Discrete output number

More information

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply

More information

NEW surge protective devices

NEW surge protective devices NEW surge protective devices For use in low-voltage systems For overhead power lines and buildings Made in EU ABOUT COMPANY INTRODUCTION Company ELEKTROMEHANIKA & BB d.o.o. was established from recent

More information

Priva Blue ID Digital input module DI4/DI8/DI16

Priva Blue ID Digital input module DI4/DI8/DI16 Priva Blue ID Digital input module Modular design An Priva Blue ID DI4 Digital input module, Priva Blue ID DI8 Digital input module or Priva Blue ID DI16 Digital input module are used to take status and

More information

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.: Extract from the online catalog MINI-DC-UPS/12DC/4 Order No.: 2866598 Uninterruptible power supply with integrated power supply unit, 4 A, in combination with MINI-BAT/12/DC 1.6 Ah or 2.6 Ah Commercial

More information

TM3DI16G module TM3-16 inputs spring

TM3DI16G module TM3-16 inputs spring Characteristics module TM3-16 inputs spring Main Range of product Product or component type Range compatibility Modicon TM3 Discrete input module Modicon M221 Modicon M241 Modicon M251 Discrete input number

More information

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications. EN ADAMCZEWSKI Elektronische Messtechnik GmbH Felix-Wankel-Str. 13 / 74374 Zaberfeld Tel. +49 (0)7046-875 Fax +49 (0)7046-7678 vertrieb@ad-messtechnik.de Operating Instructions Supply Isolation Amplifier

More information

NPort 5100 Series Quick Installation Guide

NPort 5100 Series Quick Installation Guide NPort 5100 Series Quick Installation Guide Edition 4.0, November 2015 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

Hazardous Area Protection

Hazardous Area Protection Hazardous Area Protection Global Solutions in Hazardous Area Surge and Lightning Protection Intrinsic Safety When instrumentation is installed in a potentially explosive environment steps must be taken

More information

TM258LF42DT compact base M I/O - 24 V DC - CANopen

TM258LF42DT compact base M I/O - 24 V DC - CANopen Characteristics compact base M258-42 I/O - 24 V DC - CANopen Main Range of product Product or component type Product specific application Discrete I/O number 42 Discrete output number Modicon M258 Logic

More information

TM258LF42DT compact base M I/O - 24 V DC - CANopen

TM258LF42DT compact base M I/O - 24 V DC - CANopen Characteristics compact base M258-42 I/O - 24 V DC - CANopen Main Range of product Product or component type Product specific application - Discrete I/O number 42 Discrete output number Complementary Discrete

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12

More information

SPM91 DIN Rail Single Phase Energy Meter Installation & Operation Manual V1.0

SPM91 DIN Rail Single Phase Energy Meter Installation & Operation Manual V1.0 SPM91 DIN Rail Single Phase Energy Meter Installation & Operation Manual V1.0 ZHUHAI PILOT TECHNOLOGY CO., LTD. I Danger and warning! This device can be installed only by professionals. The manufacturer

More information

SPD Catalogue. SPD Catalogue. for AC applications

SPD Catalogue. SPD Catalogue. for AC applications SPD Catalogue SPD Catalogue for AC applications Eaton and Cooper united. Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability and make

More information

Transmitters. Model 310 Programmable Analog. User Manual. XMT-UM EN-07 (July 2015)

Transmitters. Model 310 Programmable Analog. User Manual. XMT-UM EN-07 (July 2015) Transmitters Model 310 Programmable Analog XMT-UM-01653-EN-07 () User Manual Transmitters, Model 310 Programmable Analog CONTENTS Description 3 Scope and Purpose 3 Mechanical Installation 3 Location 3

More information