Based Technology SIMOCRANE. Drive-Based Technology. Preface. System overview. Hardware interfaces. Software structure. DCC blocks.

Size: px
Start display at page:

Download "Based Technology SIMOCRANE. Drive-Based Technology. Preface. System overview. Hardware interfaces. Software structure. DCC blocks."

Transcription

1 Drive- Based Technology Preface System overview 1 SIMOCRANE Operating Instructions Hardware interfaces 2 Software structure 3 DCC blocks 4 Communication 5 Commissioning 6 Standard applications and adaptation options 7 Spare parts / accessories 8 A Appendix valid for SIMOCRANE V1.0 SP1 Hardware - SINAMICS CU firmware V4.5 (for cranes) 07/2012

2 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: Trademarks WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Industry Sector Postfach NÜRNBERG GERMANY P 08/2012 Technical data subject to change Copyright Siemens AG All rights reserved

3 Preface This document is part of the SIMOCRANE product. It describes the DCC blocks for crane technology, control via PROFIBUS DP or terminals (I/O) and the standard application solution for cranes. The standard application is suitable for both "Ready-to-Run" applications (parameterization only) and "Ready-to-Apply" applications (adapted by users). Prerequisite (area of validity) This manual is valid for use with SINAMICS S120 in conjunction with the following product versions: Hardware: SINAMICS CU310-2 Firmware V4.5 (for cranes) Software: STARTER V4.3.1 SINAMICS DCC V2.2 SP1 option package SIMOCRANE V1.0 SP1 Additional information The latest information about SINAMICS products, product support, and FAQs can be found on the Internet here ( The latest information about SIMOCRANE products, product support, and FAQs can be found on the Internet here ( You can find information about Crane Application Notes on the Internet here ( Application support for cranes Operating Instructions, 07/2012 3

4 Preface Product support for SIMOCRANE Use the following addresses to receive support for your SIMOCRANE products: Support request in the Internet: Europe hotline Tel.: +49 (0) Fax: +49 (0) support.automation@siemens.com America hotline Tel.: Fax: support.america.automation@siemens.com Asia/Pacific hotline Tel.: Fax: support.asia.automation@siemens.com Additional support We also offer training courses to help you familiarize yourself with SIMOCRANE Drive- Based Technology. You can find more information here ( If you have any additional questions please contact your local Siemens sales person. 4 Operating Instructions, 07/2012

5 Table of contents Preface System overview Hardware interfaces Handling a CU310-2 CF card CU310-2 interfaces BOP20 Basic Operator Panel Software structure Closed-loop control structure DCC blocks General information DCC block MasterSwitch DCC block StartPulse DCC block PreLimitSwitch DCC block OverSpeed DCC block CurrentDistribution DCC block LoadDependingFieldWeak Communication Task distribution Configuring the PROFIBUS connection Communication SIMATIC SINAMICS Communication SINAMICS SIMATIC Configuring the I/O connection Commissioning General information Controlling the crane taking the PROFIdrive profile into account Switch on the drive Switch off the drive Mechanical motion stop SINAMICS drive object Cranes DCC blocks Function (DCC block) "Load-dependent field weakening" Theoretical basics and equations Commissioning instructions Generating the measured variables...77 Operating Instructions, 07/2012 5

6 Table of contents Compensating the frictional torque Correcting the efficiency Calculating the physical size of the load Criteria for enabling field weakening Load curves in examples Example 1: Constant power Example 2: Curve is specified (no constant power) The trace function Recording DCC input and output parameters Standard applications and adaptation options Standard application, SingleAxis Setpoint channel StartPulse in combination with brake control Master-slave operation for SingleAxis Expanding a standard application and DCC chart Data units Converting a BiCo parameter into an adjustable parameter Spare parts / accessories A Appendix A.1 List of References A.2 Abbreviations A.3 Differences to Basic Technology from a terminology perspective Operating Instructions, 07/2012

7 System overview 1 A sector solution based on the platform of SIMOTION / SINAMICS SIMOCRANE Basic Technology was launched into the market in the middle of The new platform based on SIMATIC + SIMOTION + SINAMICS is available for both harbor and industrial cranes. The solution covers high-performance crane applications and allows a modular, scalable closedloop control system for all types of cranes (Ref. [6]) by adding the Advanced Technology (e.g. Sway Control). However, in the meantime, the industrial crane market has developed further at a fast rate. As a consequence, in recent years a broad range of applications for mid-performance cranes has been opened up. With SIMOCRANE, Siemens Crane meets the challenges of this market. The new mid-performance crane solution will not take market share from SIMOCRANE Basic Technology. In fact, the SIMOCRANE perfectly adapts this high performance solution to the mid-performance market. SIMOCRANE is drive-based and offers a compact functional scope within the SINAMICS environment. Highlights of are fast commissioning by using standard applications and a high degree of flexibility through the appropriate adaptation possibilities. SIMOCRANE encompasses the following features: All of the functions that have been proven in practice and required for mid-performance applications can be found on the new SINAMICS platform for parameterization. Preconfigured standard applications for hoist and trolley/gantry with control via I/O signals or PROFIBUS DP (ready-to-run, parameterization only, selection using a script). Can be adapted for customer-specific requirements - "Ready-to-apply" (for adaptation by the user). V1.0 SP1 special feature The SIMOCRANE V1.0 with SINAMICS CU310 was launched on the market at the end of The innovation of the SINAMICS CU310-2 developed a crane-specific SINAMICS firmware so that the CU310-2 can operate the PM340 Power Modules, PM Chassis and PM250. The focus of the new version SIMOCRANE Drive-Based Technology V1.0 SP1 is the adaptation to the market requirement and the further developed SINAMICS software and hardware. The functional scope has been moderately expanded for the new version. The new onboard I/O on the CU310-2 simplifies the control of the standard application. This saves the need for an additional Terminal Module for simple applications. Other customer requirements are taken into account in applications, such as digital master switch, combination between StartPulse and SINAMICS brake control system, commissioning using the BOP20, etc. Operating Instructions, 07/2012 7

8 System overview Scope of supply The previous SIMOCRANE V1.0 with SINAMICS CU310 (order number: 6GA7270-1AA10-0AA0) package will continue to be sold. In parallel, the SIMOCRANE V1.0 SP1 with SINAMICS CU310-2 (order number: 6GA7270-1AA11-0AA0) package is supplied. This means as customer you can choose between these two packages depending on the project and the system. The SIMOCRANE scope of delivery includes: SIMOCRANE V1.0 One memory card (CF card) with the firmware version for SINAMICS S120 (V2.6.2) One CD with Cranes DCC blocks Standard applications Documentation SIMOCRANE V1.0 SP1 One memory card (CF card) with crane-specific firmware version for SINAMICS S120 (V4.5) One CD with Cranes DCC blocks Standard applications Documentation 8 Operating Instructions, 07/2012

9 System overview Functional scope Table 1-1 SIMOCRANE functional scope No. Function Brief description 1 Load-dependent field weakening Using the LoadDependingFieldWeak DCC block, a supplementary speed setpoint is calculated dependent on the load. This speed increase for partial loads above the rated speed is required for cranes to increase the handling capacity. 2 Prelimit switch (selectable limiting) Using this DCC block, when a pre-defined pre-limit switch is reached, the drive velocity can be limited. 3 Start pulse Using this DCC block, "load sag" when starting hoisting gear with a suspended load is prevented. 4 Current distribution monitoring This DCC block is used to compare the current setpoint or actual value of the master and slave. A message is generated if a specified difference is exceeded. 5 Master switch Using this DCC block, the drive can be moved with a fine sensitivity via a directly connected master switch for manual positioning. 6 Overspeed monitoring Using the DCC block OverSpeed, the overspeed can be monitored or a setpoint-actual value deviation can be identified (this is not a fail-safe function). 7 Time-optimized positioning for a single axis 8 Master-slave closed-loop torque control Using the function module "basic positioning" in SINAMICS, the drive can be moved to the target position as quickly as possible and precisely with the specified maximum velocity and acceleration/deceleration. Master-slave operation is used if two motors are connected to a common shaft. The master operates either in the closed-loop speed or position controlled mode, the slave operates in the closed-loop torque controlled mode. The master sends the torque as torque setpoint to the slave. The communication between master-slave drive must be performed as part of the application solution. 9 Brake control The simple or extended brake control allows the user to parameterize rather than program the control. The combination of start pulse and brake control simplifies the engineering and commissioning for the user. 10 Safety Integrated If required, the SINAMICS Safety Integrated basic and extended functions are available for the user, e.g. STO, SLS. Operating Instructions, 07/2012 9

10 System overview 10 Operating Instructions, 07/2012

11 Hardware interfaces Handling a CU310-2 CF card The firmware and parameters with the factory settings are stored on the CF card inserted in the CU310-2 Control Unit. Note The CF card may only be inserted in the Control Unit when in the no-voltage condition. 2.2 CU310-2 interfaces The CU310-2 DP Control Unit (PROFIBUS) is a control module for single-motor drives in which the open-loop and closed-loop control functions of the drive are implemented. It controls the Power Modules in the blocksize format via the PM-IF interface. The Chassis Power Modules are controlled from the Control Unit via the DRIVE-CLiQ interface. The CU310-2 DP is hot-pluggable. It can be used as of firmware version 4.5 (for cranes). The table shows an overview of the interfaces on the CU310-2 DP. Table 2-1 Overview of the interfaces on the CU310-2 DP Type Number Isolated digital inputs 11 Non-isolated digital inputs/outputs 8 Isolated digital output 1 Non-isolated analog input 1 DRIVE-CLiQ interface 1 PROFIBUS interface 1 Serial interface (RS232) 1 Encoder interface (HTL/TTL/SSI) 1 LAN (Ethernet) 1 Temperature sensor input 1 EP terminal 1 Test sockets 3 Operating Instructions, 07/

12 Hardware interfaces 2.2 CU310-2 interfaces Figure 2-1 CU310 DP-2 interfaces The interface to the Power Module is located at the rear of the CU310-2 DP. Figure 2-2 CU310-2 DP interface to the Power Module (PM-IF) 12 Operating Instructions, 07/2012

13 Hardware interfaces 2.2 CU310-2 interfaces Figure 2-3 CU310-2 DP connection example For additional information refer to Ref. [1] Operating Instructions, 07/

14 Hardware interfaces 2.3 BOP20 Basic Operator Panel 2.3 BOP20 Basic Operator Panel Figure 2-4 BOP20 Basic Operator Panel The BOP20 Basic Operator Panel is a basic operator panel with six keys and a backlit display unit. It can be inserted in the SINAMICS CU310-2 DP Control Units or CU310-2 PN and operated there. Functional scope Entering parameters and activating functions Display of operating modes, parameters, alarms and faults Displays and keys RUN S P C FN P Figure 2-5 BOP20 displays and keys 14 Operating Instructions, 07/2012

15 Hardware interfaces 2.3 BOP20 Basic Operator Panel Table 2-2 Display top left 2 positions RUN top right 2 positions Displays Meaning The active drive object of the BOP is displayed here. The displays and key operations always refer to this drive object. It illuminates when the displayed drive is in the RUN state (in operation). The following is displayed in this field: More than 6 digits: characters that still exist but are not visible (e.g. "r2": two characters to the right are not visible, "L1": one character to the left is not visible) Faults: selects/displays other drives with faults Designation of BICO inputs (bi, ci) Designation of BICO outputs (bo, co) The source object of a BICO interconnection to a drive object differs from the active one S It illuminates when at least one parameter was changed and the value was not transferred to the non-volatile memory. P It illuminates when the value for a parameter becomes effective only after pressing the P key. C It illuminates when at least one parameter was changed and the calculation for consistent data management has still not been initiated. Below, 6 digit Displays, e.g. parameters, indices, faults and alarms. Table 2-3 BOP20 keys 1) Key Name Effect FN P ON 2) OFF 2) Functions 3) Parameter Raise Lower Power-up the drives for which the "ON/OFF1", "OFF2" or "OFF3" commands should come from the BOP. Power-down the drives for which the "ON/OFF1", "OFF2" or "OFF3" commands should come from the BOP. The effect of this key depends on the current display. The effect of this key depends on the current display. These keys depend on the current display; use these keys to set the displayed values higher or lower. 1) The structure of the BOP control word corresponds to the structure of the PROFIBUS control word. 2) The effect of this key can be defined using the appropriate BICO parameterization (for example, you can use this key to control all axes concurrently). 3) The effect of this key to acknowledge faults can be defined using the appropriate BICO parameterization. Operating Instructions, 07/

16 Hardware interfaces 2.3 BOP20 Basic Operator Panel Note Further information about the BOP20 is contained in the SINAMICS S120 Commissioning Manual. 16 Operating Instructions, 07/2012

17 Software structure 3 Every main drive has a speed setpoint channel, generated in the graphic programming language "Drive Control Charts" (DCC), and additionally monitors various functions (e.g. current distribution monitoring, overspeed). All crane-specific technologies are implemented in a DCC chart. The number and functionality of the DCC blocks in this chart are identical for all main drives. The DCC blocks not required must be disabled in the execution system in the STARTER expert list in order to avoid any unnecessary computational load. Note When scripting is used, the connections for the DCC blocks and the control after selection of the drive type (hoist or trolley), communication (PROFIBUS DP or terminals) and masterswitch type (digital or analog) are performed automatically. Figure 3-1 Software structure using control via PROFIBUS DP as example Operating Instructions, 07/

18 Software structure 3.1 Closed-loop control structure 3.1 Closed-loop control structure A speed setpoint is read in from the S7 or from the Onboard Terminals. This speed setpoint is connected to the input of the Crane DCC block MasterSwitch. The setpoint is then transferred to the main setpoint channel of the SINAMICS basic system after processing via the DCC blocks LoadDependingFieldWeak and PreLimitSwitch; refer to the following diagrams. Figure 3-2 Hoist setpoint channel using the example of control via PROFIBUS Figure 3-3 Gantry/trolley setpoint channel using the example of the control via PROFIBUS 18 Operating Instructions, 07/2012

19 Software structure 3.1 Closed-loop control structure Speed path The setpoint speed is first interconnected to the block MasterSwitch in the DCC. If the master switch functionality is to be used, then the master switch curve must be configured and enabled. Otherwise, the speed setpoint is directly connected from the input to the block output without any change. The speed setpoint is then connected to the LoadDependingFieldWeak block (only for hoisting gear applications). When traveling at a constant speed in the rated speed range, this block determines the load. The maximum speed is limited as a function of the load. The speed setpoint is further connected to the PreLimitSwitch block. Depending on the control, the setpoint speed is reduced. Finally, the setpoint speed is interconnected with the main setpoint of the SINAMICS basic system. Note The StartPulse function is combined with the SINAMICS brake control, see Section StartPulse in combination with brake control (Page 95). Note The output signal of the digital master switch is evaluated by the application and interconnected with the DigitalMasterSwitch DCC block. The output of the digital master switch supplies an incremental speed setpoint, see Section Setpoint channel (Page 91). Operating Instructions, 07/

20 Software structure 3.1 Closed-loop control structure 20 Operating Instructions, 07/2012

21 DCC blocks General information The SIMOCRANE Cranes DCC blocks contain the crane technology functions. Note Each main drive has a DCC chart that contains the crane-technology functions. The DCC chart is closed and the DCC blocks are adapted to the requirements of the application via the appropriate parameters in the expert list. Additional DCC applications can be implemented using a separate DCC chart under the Control Unit or under another drive object. For additional information on this topic, refer to Expanding a standard application and DCC chart (Page 98) or Ref. [3] Note There is no online help in the expert list for the user-defined parameters. WARNING Material damage as well as injury to personnel can occur if the preconfigured run sequence inside of the DCC blocks is changed. If not otherwise noted, then the following statements apply to all DCC blocks: Firmware version STARTER: Software V4.3.1 or higher SINAMICS: Firmware V4.5 (for cranes) Configuration The DCC blocks can be configured in cyclic tasks. Any delays (dead times) must be avoided in the setpoint channel in configuring cyclic tasks. The following sequence is recommended when all blocks are configured in one execution level: 1. Master switch 2. LoadDependingFieldWeak (is only required for hoisting gear applications) 3. PreLimitSwitch 4. StartPulse (is only required for hoisting gear applications) Operating Instructions, 07/

22 DCC blocks 4.1 General information 5. OverSpeed 6. CurrentDistribution (is only required for synchronous operation or master-slave applications) Setting tip Master switch LoadDependingFieldWeaking PreLimitSwitch StartPulse OverSpeed CurrentDistribution p21000[0] = [3005] PRE basic positioner p21000[1] = [3005] PRE basic positioner p21000[2] = [3005] PRE basic positioner p21000[3] = [3005] PRE basic positioner p21000[4] = [3005] PRE basic positioner p21000[5] = [3005] PRE basic positioner Explanation All inputs/outputs of DCC blocks have a pre-assigned value. The value can be pre-assigned from two locations: If the input/output is not assigned, the default value applies. The input/output is linked to a parameter from the DCC block. Internally, SINAMICS DCC operates only with percentage values, i.e. if a speed value is linked to a DCC block input, the absolute value in revolutions per minute is not used, but rather a percentage value in the DCC block. The conversion from absolute to percentage values is always implemented using the reference value in parameters p2000 to p2003 or r2700 to r2703. This is the reason that the following declaration applies for the reference values: p2000 = r2700 = reference speed reference frequency ( p1082 = maximum speed) p2001 = r2701 = reference voltage p2002 = r2702 = reference current p2003 = r2703 = reference torque Note All reference data must be normalized to their maximum value: nmax = nreference = 100% = nrated + nfw (maximum speed = reference speed = rated speed + field weakening speed) Imax = Ireference = 100% = Irated + Ioverload (maximum current = reference current = rated current + overload current) Mmax = Mreference = 100% = Mrated + Moverload (maximum torque = reference torque = rated torque + overload torque) 22 Operating Instructions, 07/2012

23 DCC blocks 4.1 General information Connections and data types The connection name must often be shortened due to the restricted number of characters. The shortened designators of the data types and prefixes are listed in the following table. Prefix DCC Elementary designations (designators) Value range bo BOOL Bit (1) TRUE, FALSE b BYTE Byte (8) 16# #FF b WORD Word (16) -2**15...2**15-1 b DWORD Double word (32) -2**31...2**31-1 i INT Integer number (16) -2**15...2**15-1 i DINT Double integer number (32) -2**31...2**31-1 r REAL Floating-point number (32) Refer to IEC 559 Connection type Abbreviation IN OUT Connection type Input Output Examples Table 4-1 DCC blocks bocommandopenbrake BOOL Input Open brake rinspeedsetpointpls REAL Input Speed input value booutenablefieldweak BOOL Output Field weakening active Note "in" or "out" is not included in every connection name, but only then, if otherwise the connection names would be the same. Example: rinspeedsetpointms routspeedsetpointms Operating Instructions, 07/

24 DCC blocks 4.2 DCC block MasterSwitch Note In the expert list in STARTER, the name of the DCC block is used as a prefix for the parameter name, so that an allocation can be made to the particular DCC block, i.e. in STARTER: [parameter number] [name of the DCC block]_[parameter name] in these operating instructions: [parameter number] "[parameter name]" Example: in STARTER: p22000 MasterSwitch_rInSpeedSetpointMS in these operating instructions: p22000 "rinspeedsetpointms". Note If a DCC input is linked with a value from the basic unit, then an automatic conversion is made to the drive connectors that have associated units. If an interconnection is established to this input from another DCC chart, then this value may only be in the range -2.0 to In SINAMICS DCC, 100% corresponds to a value of 1.0, i.e. 200% corresponds to a value of DCC block MasterSwitch Symbol 24 Operating Instructions, 07/2012

25 DCC blocks 4.2 DCC block MasterSwitch Short description Using the MasterSwitch DCC block - for manual positioning - the drive can be moved with a fine sensitivity via a directly connected master switch. This DCC block has a 6-point polygon function. Mode of operation The master switch supplies a setpoint that is directly proportional to its angle of deflection. In order that for low deflection angles lower speed setpoints are obtained than those that correspond linearly to the deflection angle, the master switch setpoint is passed through a non-linear function. This allows the drive to be precisely positioned in the manual mode. For low deflection angles, this results in lower speed changes than for the same change of the deflection angle in the medium and higher deflection range. The non-linear function is realized in quadrant I using 6 adjustable straight-line sections, whereby the zero point is given. Quadrant III is mirrored as a result of the inputs from quadrant I. The inputs p22002 "bopositivedeflection" (positive deflection) and p22003 "bonegativedeflection" (negative deflection) are read in. Depending on the polarity read in, either a positive or a negative speed setpoint is output at the block output. Only 1 input may be active at any time. However, if both inputs are active at the same time, or both inputs are not active, then the block outputs a speed setpoint of ZERO at its output. Further, for a positive setpoint input at the block input and if input p22003 "bonegativedeflection" is set, then a negative speed setpoint is given at the block output. For a negative setpoint input at the block input and if input p22003 "bopositivedeflection" is set, then a positive speed setpoint is given at the block output. The polarity of the setpoint input at the block input p22000 "rinspeedsetpointms" is not taken into account. Operating Instructions, 07/

26 DCC blocks 4.2 DCC block MasterSwitch Figure 4-1 Non-linear modeling of the master switch Note The inputs p22002 "bopositivedeflection" and p22003 "bonegativedeflection" are decisive for the polarity of the speed setpoint at the block output. The polarity of the setpoint input at the block input is not taken into account. WARNING Ensure that you enter the correct values for the polygon function parameter! Input parameters p22004, p22006, p22008, p22010, p22012 and p22014 "rx1deflectionparameter" to "rx6deflectionparameter" and p22005, p22007, p22009, p22011, p22013 and p22015 "ry1speedparameter" to "ry6speedparameter" must be assigned in an ascending sequence. Proper operation of the block cannot be guaranteed if you do not set the parameters correctly. For the X polygon parameters ("rx1deflectionparameter" to "rx6deflectionparameter"), the percentage value of the degree of deflection is entered. For the Y polygon parameters ("ry1speedparameter" to "ry6speedparameter"), the percentage value of the reference or maximum speed is entered. 26 Operating Instructions, 07/2012

27 DCC blocks 4.2 DCC block MasterSwitch Connections SINAMICS Parameter No. Name Connection type Default assignment Data type Meaning p22000 rinspeedsetpointms IN 0% REAL Master switch input value, conversion degree of deflection p22001 boenablemasterswitch IN 0 BOOL Enabling the master switch function If this function is enabled, then the master switch setpoint is influenced by the master switch curve. p22002 bopositivedeflection IN 0 BOOL Master switch deflected in the positive direction. p22003 bonegativedeflection IN 0 BOOL Master switch deflected in the negative direction. p22004 rx1deflectionparameter IN 5.0 REAL Degree of deflection [%] p22005 ry1speedparameter IN 5.0 REAL Speed [%] p22006 rx2deflectionparameter IN 10.0 REAL Degree of deflection [%] p22007 ry2speedparameter IN 10.0 REAL Speed [%] p22008 rx3deflectionparameter IN 25.0 REAL Degree of deflection [%] p22009 ry3speedparameter IN 25.0 REAL Speed [%] p22010 rx4deflectionparameter IN 50.0 REAL Degree of deflection [%] p22011 ry4speedparameter IN 50.0 REAL Speed [%] p22012 rx5deflectionparameter IN 75.0 REAL Degree of deflection [%] p22013 ry5speedparameter IN 75.0 REAL Speed [%] p22014 rx6deflectionparameter IN REAL Degree of deflection [%] p22015 ry6speedparameter IN REAL Speed [%] r22016 routspeedsetpointms OUT 0.0 REAL Master switch output value [%] For hoisting gear applications, this output must be connected to input p22130 "rinspeedsetpoint" at the LoadDependingFieldWeak block. For long travel applications, this output must be connected to input p22050 "rinspeedsetpointpls" at the PreLimitSwitch block. Operating Instructions, 07/

28 DCC blocks 4.3 DCC block StartPulse 4.3 DCC block StartPulse Symbol Brief description Using the StartPulse DCC block, when starting hoisting gear with a suspended load, socalled "load sag" is either prevented or reduced. Note The block is only required for hoisting gear applications. In hoisting gear applications, the block must be activated in the execution system (p21000[n]). For all other applications, the block must be deactivated in the execution system (p21000[n]). Mode of operation For hoisting gear, when starting - and therefore when opening the hoisting gear brakes - with freely suspended load, often the load undesirably sags. The cause is the missing torque that must first be established from the time when the command "open brake" is issued, which involves the processing time of the system. This means that when the command to open the brake is issued, the corresponding torque for the load must be available to prevent the load from sagging. This is achieved using the start pulse. To do this, the torque at the output of the speed controller at standstill is retentively saved with p22071 "rtorquevalueretain" before the brake is closed. The speed controller is set to the retentively saved value using parameter r22077 "rsettorquevalue" when the signal to open the brake is output. This means that the torque is quickly established - therefore preventing load sag. The direction of the start pulse is always in the hoisting direction. In addition, using parameter p22076 "rstartpulsetime", the time that output parameter r22078 "bosettorque" remains available can be specified in milliseconds. The schematic of the logic circuitry is shown in the following diagram. WARNING Incorrect start pulse values may lead to injury and material damage. 28 Operating Instructions, 07/2012

29 DCC blocks 4.3 DCC block StartPulse Figure 4-2 Mode of operation of the DCC block StartPulse Connections SINAMICS parameter number Name Connection type Default assignment Data type Meaning p22070 boenablebrakestorevalue IN 0 BOOL Enable signal to save the actual torque when closing the brake and to set the actual torque when opening the brake. Only when the input has been set, is the block ready to save values or to output saved values. If the input is not set, the outputs are always FALSE and ZERO. p22071 rtorquevalueretain IN 0% REAL Torque setpoint from the speed controller (I component) [%]. The input must be connected to SINAMICS parameter r1482[0]. p22072 bocommandopenbrake IN 0 BOOL "Open brake" signal The input must always be set with a positive edge in order to control the r22078 output. p22073 bocommandclosebrake IN 0 BOOL "Close brake" signal p22074 boenablefixedvalue IN 0 BOOL Enables the fixed torque setpoint instead of the actual output value of the speed controller (I component). p22075 rtorquevalue IN 0% REAL Torque setpoint from the higher-level control [%]. p22076 rstartpulsetime IN REAL Longest period that the output signal "bosettorque" [ms] remains available. Operating Instructions, 07/

30 DCC blocks 4.4 DCC block PreLimitSwitch SINAMICS parameter number Name Connection type Default assignment Data type Meaning r22077 rsettorquevalue OUT 0.0 REAL Torque setpoint [%] The output must be connected to SINAMICS parameter p1478[0]. r22078 bosettorque OUT 0 BOOL Signal to set the torque when opening the brake. The output must be connected to SINAMICS parameter p1477[0]. Note In the standard applications, the StartPulse function is combined with the SINAMICS brake control, see Section StartPulse in combination with brake control (Page 95). 4.4 DCC block PreLimitSwitch Symbol Short description The speed of the drive can be influenced using the DCC block PreLimitSwitch. 30 Operating Instructions, 07/2012

31 DCC blocks 4.4 DCC block PreLimitSwitch Mode of operation This function prevents that the drive moves with full speed to the limit switch or to the safety buffer. A total of three different speed limits can be configured. When a BERO proximity switch is passed, the bit matching the BERO proximity switch is set and therefore the setpoint speed limited. The reference or maximum speed must be interconnected to speed limit 1. As a consequence, the speed is limited to the reference or maximum speed. Speed limits 2 to 3 are controlled through inputs p22051 "Bit1LimitSpeed" and p22052 "Bit2LimitSpeed". Speed limit 4 is controlled via p22053 "boprelimitswitch". Selecting speed limiting Bit1LimitSpeed p22051 Bit2LimitSpeed p22052 PreLimitSwitch p22053 Speed limiting 1 (p22054) FALSE FALSE FALSE Speed limiting 2 (p22055) TRUE FALSE FALSE Speed limiting 3 (p22056) FALSE TRUE FALSE Speed limiting 4 (p22057) no influence no influence TRUE Setting the speed limits: The speed limits should be set as follows: Speed limit 1 (p22054) > speed limit 2 (p22055) Speed limit 2 (p22055) > speed limit 3 (p22056) Speed limit 3 (p22056) > speed limit 4 (p22057) Setting tip: Speed limiting 1 = Reference or maximum speed Speed limiting 2 = 50% of the reference or maximum speed Speed limiting 3 = 25% of the reference or maximum speed Speed limiting 4 = 5% of the reference or maximum speed Operating Instructions, 07/

32 DCC blocks 4.4 DCC block PreLimitSwitch Figure 4-3 Mode of operation of the DCC PreLimitSwitch Connections SINAMICS Parameter No. Name Connection type Default assignment Data type Meaning p22050 rinspeedsetpointpls IN 0% REAL Speed input value [%] For hoisting gear applications, this input must be connected to output r22156 "routspeedsetpoint" at the LoadDependingFieldWeak block. For long travel applications, this input must be connected to output r22016 "routspeedsetpointms" at the MasterSwitch block. p22051 bobit1limitspeed IN 0 BOOL Select speed limitation, bit 1 p22052 bobit2limitspeed IN 0 BOOL Select speed limitation, bit 2 p22053 boprelimitswitch IN 0 BOOL Selects prelimit switch limiting p22054 rlimit1 IN REAL Speed limiting 1 This limit should be set as maximum speed [%]. p22055 rlimit2 IN 50.0 REAL Speed limiting 2 [%] p22056 rlimit3 IN 25.0 REAL Speed limiting 3 [%] 32 Operating Instructions, 07/2012

33 DCC blocks 4.5 DCC block OverSpeed SINAMICS Parameter No. Name Connection type Default assignment Data type Meaning p22057 rlimit4 IN 5.0 REAL Speed limiting 4 [%] r22058 routspeedsetpointpls OUT 0.0 REAL Speed output value [%] The output must be connected to SINAMICS parameter p1070[0]. 4.5 DCC block OverSpeed Symbol Brief description Using the DCC block OverSpeed, the overspeed can be monitored or a setpoint-actual value deviation can be identified. Mode of operation Note The overspeed can also be directly handled in the SINAMICS; see function diagram 8010 in the SINAMICS S 120/150 List Manual (Ref. [2]). Using this function, the actual speed can be monitored for an overspeed condition and a setpoint-actual value deviation detected. A limit is defined for the setpoint-actual value deviation. If the actual speed exceeds this limit for the parameterized delay time p22040 "rdelaytime", then output r22041 "booverspeed" is set. This limit is the sum of the speed setpoint p22030 "SpeedSetpoint" and the offset p22039 "roffset". The setpoint-actual value monitoring is activated using input p22038 "boenablesetpointactualmonitoring". Operating Instructions, 07/

34 DCC blocks 4.5 DCC block OverSpeed The overspeed detection is implemented in the software for various speeds (field weakening operation and rated speed). If the specified offset (p22039 "roffset") is exceeded for one of the two speeds for longer than the parameterized delay time, then this is signaled using output r22041 "booverspeed". If the drive is in the field-weakening range, the actual speed is compared with the setpoint speed from the load-dependent field weakening p22034 "rafterrampgenspeed". If the actual speed is greater than the setpoint speed from the load-dependent field weakening plus the configured permissible deviation, then an overspeed condition is identified and is output at the block output. The speed setpoint of the load-dependent field weakening is only used as comparison value if the drive is in the field-weakening range and field-weakening operation has been enabled for the drive. The comparison value of the load-dependent field weakening is used until the determined load is reset. The overspeed monitoring is sent from SINAMICS via PROFIBUS in the application status word 1, bit 3. In SINAMICS, the signal is connected to the onboard I/O by means of BICO technology, see the table below. The SIMATIC S7 is connected to the SINAMICS CU onboard I/Os via a wire connection, reads in this signal and evaluates the signal status. Output r22041 "booverspeed" is reset using parameter p22037 "boreset". The p22037 "boreset" parameter should be connected with the r "Acknowledge fault" parameter. The r22041 "booverspeed" output parameter for PROFIBUS DP and for I/O should be connected with the p2082[3] "application_status_word_1, bit 3" parameter and the p746 "Digital output 16" parameter, respectively. Table 4-2 Interconnection of the overspeed signal Drives Terminal CU output Hoist 1 X DO Operating Instructions, 07/2012

35 DCC blocks 4.5 DCC block OverSpeed Figure 4-4 DCC block OverSpeed, variable "boenablesetpointactualmonitoring" = FALSE Note The rated speed must be input in the unit [rpm] at input p22032 "rratedspeed". The reference or maximum speed must be connected in unit [rpm] with display parameter r2700 at input p22033 "rreferencespeed". The block does not work correctly otherwise. Operating Instructions, 07/

36 DCC blocks 4.5 DCC block OverSpeed Figure 4-5 DCC block OverSpeed, variable "boenablesetpointactualmonitoring" = TRUE 36 Operating Instructions, 07/2012

37 DCC blocks 4.5 DCC block OverSpeed Connections SINAMICS parameter number Name Connection type Default assignment Data type Meaning p22030 rspeedsetpoint IN 0% REAL Setpoint speed [%] The input must be connected to SINAMICS parameter r0062. p22031 ractualspeed IN 0% REAL Actual drive speed [%] The input must be connected to SINAMICS parameter r0063. p22032 rratedspeed IN REAL Rated speed [rpm] p22033 rreferencespeed IN 0% REAL Reference or maximum speed [rpm] The input must be connected to SINAMICS parameter r2700. p22034 rafterrampgenspeed IN 0% REAL Speed setpoint from the loaddependent field weakening [%]. The input must be connected to output r22159 "raddsetpointspeedafterpli" of the LoadDependingFieldWeak block. p22035 boenablefieldweak IN 0 BOOL Field weakening active The input must be connected to output r22158 "booutenablefieldweak" of the LoadDependingFieldWeak block. p22036 boresetloadcurrent IN 0 BOOL Load is reset from the load-dependent field weakening. p22037 boreset IN 0 BOOL Reset the "booverspeed" output. The input must be connected with the SINAMICS r "Acknowledge fault" parameter. p22038 boenablesetpointactualm on IN 0 BOOL Activation of the setpoint-actual value monitoring. p22039 roffset IN 10.0 REAL Offset input [%] p22040 rdelaytime IN REAL Delay time in [ms] r22041 booverspeed OUT 0 BOOL Overspeed active - PROFIBUS DP: p2082[3] - I/O: p746 Operating Instructions, 07/

38 DCC blocks 4.6 DCC block CurrentDistribution 4.6 DCC block CurrentDistribution Symbol Short description The currents of the master and slave are monitored using the DCC block CurrentDistribution. An error message is generated if a deviation is exceeded. Mode of operation Note This block is only required for synchronous operation or master-slave applications. In these applications, the block must be activated in the execution system (p21000[n]). For all other applications, the block must be deactivated in the execution system (p21000[n]). This function can be used for master-slave operation or synchronous operation. The block monitors that the total current of both drives is distributed evenly. However, for crane applications this is not always the case. In synchronous operation, the current setpoint is monitored for the two drives. In masterslave operation, the current actual value between the two drives is monitored; refer to the following diagram. If the difference of the setpoint currents of both drives exceeds the configured values for deviation and duration, then output r22037 "bofaultcurrentmonitoring" is set. NOTICE The reference current from SINAMICS from display parameter r2702 must be connected at input p22035 "rreferencecurrent". 38 Operating Instructions, 07/2012

39 DCC blocks 4.6 DCC block CurrentDistribution Figure 4-6 Principle of the current distribution monitoring Operating Instructions, 07/

40 DCC blocks 4.6 DCC block CurrentDistribution Connections SINAMICS Parameter No. Name Connection type Default assignment Data type Meaning p22090 rmastercurrent IN 0% REAL Master current setpoint [%] In synchronous operation, the input must be connected with the master SINAMICS parameter r0077. In master-slave operation, the input must be connected with the master SINAMICS parameter r0078. p22091 rslavecurrent IN 0% REAL Slave current setpoint [%] In synchronous operation, the input must be connected with the slave SINAMICS parameter r0077. In master-slave operation, the input must be connected with the slave SINAMICS parameter r0078. p22092 boenablecurrentmon IN 0 BOOL Enables the current comparison monitoring p22093 rdelaytime IN 20.0 REAL Delay time [ms] If a deviation occurs between the master and slave current, the output r22097 "bofaultcurrentmonitoring" is only set if the delay time has expired. p22094 rparameterlimit IN 10.0 REAL Deviation threshold [%] The master and the slave current are subtracted and then compared with the deviation threshold. p22095 rreferencecurrent IN 0% REAL Reference current [A] The input must be connected to SINAMICS parameter r2702. p22096 bomasterslaveorsynchop eration IN 0 BOOL Operating mode for master-slave or synchronous operation Current distribution is only monitored in master-slave operation or in synchronous operation. r22097 bofaultcurrentmonitoring OUT 0 BOOL Error message if the difference of the current setpoints of both drives exceeds the configured values for deviation and time. r22098 rcurrentdifference OUT 0.0 REAL Actual result of the subtraction between master and slave [A] 40 Operating Instructions, 07/2012

41 DCC blocks 4.7 DCC block LoadDependingFieldWeak 4.7 DCC block LoadDependingFieldWeak Symbol Brief description For closed-loop control drives in various operating situations an attempt is made to increase the speed above the rated speed. Using the LoadDependingFieldWeak DCC block, a supplementary speed setpoint is calculated dependent on the load. This speed increase for partial loads above the rated speed is required for cranes to increase the handling capacity. This is implemented using the motor characteristic that should be saved. Note This block is only required for hoisting gear applications. In hoisting gear applications, the block must be activated in the execution system (p21000[n]). For all other applications, the block must be deactivated in the execution system (p21000[n]). Mode of operation When field weakening is selected, e.g. from the master switch, then depending on the load, the permissible speed setpoint is given as speed limit in the setpoint input. Operating Instructions, 07/

42 DCC blocks 4.7 DCC block LoadDependingFieldWeak When traveling at constant rated speed, the load actual value is determined from the torque. The maximum speed setpoint must be available at the block input; further, the actual speed must have approximately reached the rated speed and field weakening must have been enabled. This state must be pending for the time parameterized in p22161 "rdetectionconstmove" after which the torque calculation is started. The input at the p22161 parameter is limited to minimum 100 ms in order to reliably detect a constant speed. When there are sufficient measuring points, the measurement is stopped and an arithmetic mean value is generated from these points. There must be at least 25 measuring points in order to generate a mean value. To calculate the load, the frictional torque is subtracted from this total torque and when lowering, an efficiency correction is applied. After the stationary load actual value has been calculated, depending on the determined torque, the permissible speed setpoint for constant power P = PN for field weakening is generated (using the motor characteristic, implemented as parameterizable 6 point polygon function). The permissible speed setpoint after the measurement is used as speed limit for the setpoint input. The determined load is only reset at standstill, i.e. the drive must be stationary, parameter p22133 "bonostandstill" is not set (FALSE). After this, the load can be reset with a rising positive edge at parameter p22141 "boresetloadtorque". WARNING This setting should only be carried out by qualified personnel. Particular attention must be paid to the reduced breakdown torque of the motor in the field weakening range. An appropriate safety margin must be added to the data provided by the machine manufacturer. WARNING The rated speed in unit [rpm] must be entered at input p22135 "rratedspeed" and the reference or maximum speed (p22136 "rreferencespeed") must be connected to SINAMICS display parameter r2700. The block does not work correctly otherwise. 42 Operating Instructions, 07/2012

43 DCC blocks 4.7 DCC block LoadDependingFieldWeak Figure 4-7 Motor characteristic, speed to weight as a percentage Operating Instructions, 07/

44 DCC blocks 4.7 DCC block LoadDependingFieldWeak Figure 4-8 Sequencer and principle of the DCC block WARNING Ensure that you enter the correct values for the polygon function parameter! Input parameters p22144 "rx1loadparameter" to p22154 "rx6loadparameter" must be assigned in an ascending sequence and input parameters p22145 "Y1SpeedParameter" to p22155 "Y6SpeedParameter" must be assigned in a descending sequence. Proper operation of the block cannot be guaranteed if you do not set the parameters correctly. 44 Operating Instructions, 07/2012

45 DCC blocks 4.7 DCC block LoadDependingFieldWeak Connections SINAMICS parameter number Name Connection type Default assignment Data type Meaning p22130 rinspeedsetpoint IN 0% REAL Speed setpoint [%] For hoisting gear applications, this input must be connected to output r22016 "routspeedsetpointm" at the MasterSwitch. p22131 ractualspeed IN 0% REAL Speed actual value [%] The input must be connected to SINAMICS parameter r0063. p22132 boenablefieldweak IN DCC BOOL Enabling field weakening. p22133 bonostandstill IN 0 BOOL Standstill signal, zero speed signal. The input must be connected to SINAMICS parameter r FALSE = standstill TRUE = no standstill p22134 rloadnormfactor IN 1.0 REAL Load conversion factor from current value to the physical unit tons. p22135 rratedspeed IN REAL Rated speed (base speed) [rpm]. p22136 rreferencespeed IN 0% REAL Reference or maximum speed (base speed + field weakening speed) [rpm]. The input must be connected to SINAMICS parameter r2700. p22137 rtorquesetpoint IN 0% REAL Torque setpoint [%] The input must be connected to SINAMICS parameter r0079. p22138 rtorquesmoothtime IN REAL Smoothing time for the torque [ms]. p22139 raddtorquebeforepli IN 0.0 REAL Offset [%] of the weighted torque before the motor curve. p22140 raddsetpointafterpli IN 0.0 REAL Offset [%] for the speed setpoint after the motor curve. p22141 boresetloadtorque IN 0 BOOL Reset the torque measurement p22142 refficiency_eta IN REAL 1/η 2 ; (efficiency correction between hoisting and lowering) [%]. p22143 rfrictiontorque IN 3.0 REAL Frictional torque [%] p22144 rx1loadparameter IN 0.0 REAL Load parameter value X1 [%] p22145 ry1speedparameter IN REAL Speed value Y1 [%] p22146 rx2loadparameter IN 50.0 REAL Load parameter value X2 [%] p22147 ry2speedparameter IN REAL Speed value Y2 [%] p22148 rx3loadparameter IN 60.0 REAL Load parameter value X3 [%] p22149 ry3speedparameter IN 80.0 REAL Speed value Y3 [%] p22150 rx4loadparameter IN 70.0 REAL Load parameter value X4 [%] p22151 ry4speedparameter IN 70.0 REAL Speed value Y4 [%] p22152 rx5loadparameter IN 80.0 REAL Load parameter value X5 [%] Operating Instructions, 07/

46 DCC blocks 4.7 DCC block LoadDependingFieldWeak SINAMICS parameter number Name Connection type Default assignment Data type Meaning p22153 ry5speedparameter IN 60.0 REAL Speed value Y5 [%] p22154 rx6loadparameter IN REAL Load parameter value X6 [%] p22155 ry6speedparameter IN 50.0 REAL Speed value Y6 [%] p22161 rdetectionconstmove IN REAL Delay time for constant-speed detection [ms]; values less than 100 ms are not accepted. r22156 routspeedsetpoint OUT 0.0 REAL Effective total speed setpoint [%] For hoist applications, this output must be connected to input p22050 "rinspeedsetpointpls" at the PreLimitSwitch block. r22157 rloadwithnormfactor OUT 0.0 REAL Evaluated actual position value [e.g. in tons, depending on r22134 "rloadnormfactor"]. r22158 booutenablefieldweak OUT 0 BOOL Field weakening active (all measurements are valid). r22159 raddsetpspeedafterpli OUT 0.0 REAL Effective speed setpoint in [%] relative to rmaximumvelocity. r22160 rcountsmeasurerange OUT 0.0 REAL Number of sampling operations for the measurement 46 Operating Instructions, 07/2012

47 Communication 5 The drive can be controlled via terminals (I/O) or via PROFIBUS DP. For control via terminals, only the on-board terminals are required. For PROFIBUS DP communication between the higher-level SIMATIC S7 control and the drive, a maximum of 16 process data each are provided for the send and receive directions. 5.1 Task distribution The following list provides an overview of task distribution between SIMATIC S7 and SINAMICS. SIMATIC S7 (if available) Crane overview I/O signal processing Safety-related monitoring Setpoint and control commands for main drives SINAMICS Crane technology in DCC Ramp-function generator Closed-loop speed control Closed-loop current control Monitoring, if required Positioning, if required Brake control (combined with StartPulse in a standard application) Safety Integrated function, if necessary Master-slave closed-loop torque control, if necessary Prerequisites In order to establish disturbance-free communication between the two parties, the reference data in SIMATIC and SINAMICS modules must be identically configured. The reference data must be normalized to the maximum data. Operating Instructions, 07/

48 Communication 5.1 Task distribution The following parameters are involved in the modules: SIMATIC Reference speed Reference voltage Reference current Reference torque SINAMICS p2000 = r2700 = reference speed reference frequency ( p1082 = maximum speed) p2001 = r2701 = reference voltage p2002 = r2702 = reference current p2003 = r2703 = reference torque Note All reference data must be normalized to their maximum value: nmax = nreference = 100% = nrated + nfw (maximum speed = reference speed = rated speed + field weakening speed) Imax = Ireference = 100% = Irated + Ioverload (maximum current = reference current = rated current + overload current) Mmax = Mreference = 100% = Mrated + Moverload (maximum torque = reference torque = rated torque + overload torque) The definition for the relationship between the percentage value and hexadecimal value is shown in the following table and in the following diagram. If only positive values are used in the process data, then the value range is doubled; this means that the range starts at 0 and can be increased up to 65,535 (UINT, 0 to FFFF). Table word: Connector Percentage value Hexadecimal value 0 16# # ,994 16#7FFF # #C000 0,006 16#1 48 Operating Instructions, 07/2012

49 Communication 5.2 Configuring the PROFIBUS connection Figure 5-1 Representing the value range of a word 5.2 Configuring the PROFIBUS connection The type and baud rate of the communication between SIMATIC and SINAMICS is configured in the HW-Configuration. Communication uses PROFIBUS. Communication between SIMATIC and SINAMICS is implemented using a telegram defined for (16 process data on the send side / 16 process data on the receive side). The standard telegram is extended to a free telegram (999) with 16 process data each on the send and receive sides. Note Parameter p0922 must be set to a free telegram (999) when configuring the system. With the execution of the script from the selection screen, the communication interconnection is automatically set to the correct values for the telegram data words, see Section Standard application, SingleAxis (Page 90). The address ranges for communications between SIMATIC and SINAMICS should be configured as follows. These addresses can be adapted in the HW-Configuration. Table 5-2 Address ranges of the drives Drives Address a range, I/O (peripherals) in bytes Hoist Trolley Long travel Long travel Operating Instructions, 07/

50 Communication 5.2 Configuring the PROFIBUS connection Scripts are available in the standard project. They can be used to automatically execute all the communication interconnections in SINAMICS; also see Chapter Communication SIMATIC SINAMICS (Page 52) and Communication SINAMICS SIMATIC (Page 54). In the standard application, the script (Com_S7_IO) is executed automatically from a selection screen, see Section Standard application, SingleAxis (Page 90). The script file (e.g. Com_S7_IO) is started with Accept and execute. The script file is run through and all of the necessary communication connections are generated. Note The script file should be executed offline. The changes then have to be downloaded to the drive. The script file to establish communication with the S7 control has the same name for all main drives (hoist, trolley, gantry) - namely "Com_S7_IO". The reference data should be checked and adapted in every script file. The torque setpoint (p1503) of the slave (e.g. Gantry_2) must be linked to the torque setpoint (r0079) of the master (e.g. Gantry_1) because it is not executed in the script. All connections, which are established by the script, are listed in the STARTER output window. Further, a report can be generated. The report can be saved on the hard disk. 50 Operating Instructions, 07/2012

51 Communication 5.2 Configuring the PROFIBUS connection Figure 5-2 Accepting and executing the script file You can see the actual status of the script execution in the output window. Operating Instructions, 07/

52 Communication 5.2 Configuring the PROFIBUS connection Communication SIMATIC SINAMICS Table 5-3 Process data SIMATIC SINAMICS PZD Signal name Remarks 1 Control word_1 See below, Table "Control word_1" 2 Speed setpoint The speed setpoint is specified as normalized value as a percentage (%) hex = dec = 100 % The PZD 2 must be connected with parameter p22000 "rinspeedsetpointms". 3 Control word_2 See below, Table "Control word_2" 4 Application control word_1 See below, Table "Application control word_1" 5 Setpoint for the start pulse_s7 Only for the hoist The setpoint for the start pulse is specified as normalized value as a percentage (%) hex = dec = 100 % If the setpoint for the start pulse is to be specified by the control, then PZD 5 must be connected with parameter p22075 "rtorquevalue" Free Application-related area Table 5-4 Control word_1 Bit Signal name Remarks 0 ON / OFF1 A drive is switched-on and switched-off with ON / OFF1. This signal must be connected with parameter p0840 "ON/OFF1". 1 OFF2 OFF2 must be set, otherwise the drive cannot be switched on. If input OFF2 is withdrawn when the drive is switched on, the pulses are inhibited and the motor coasts down. This signal must be connected with parameter p0844 "OFF2". 2 OFF3 OFF3 must be set - otherwise the drive cannot be switched on. If input OFF3 is withdrawn when the drive is switched on, the motor is stopped with the configured down ramp and is then switched off. This signal must be connected with parameter p0848 "OFF3". 3 Pulse enable The setpoint is only accepted and the travel command only executed when the pulse enable input is set. This signal must be connected with parameter p0852 "Operation Enable". 4 Ramp-up generator enable The ramp-function generator is enabled by setting this bit. The ramp-function generator output is set to zero when this bit is reset. This signal must be connected with parameter p1140 "Rampfunction generator enable". 5 Free 52 Operating Instructions, 07/2012

53 Communication 5.2 Configuring the PROFIBUS connection Bit Signal name Remarks 6 Enable setpoint The speed setpoint in front of the ramp-function generator is enabled when this input is set. This signal must be connected with parameter p1142 "Speed Setpoint enable". 7 Acknowledge fault When this input is set, any fault that is present is acknowledged as soon as the cause of the fault has been removed. This signal must be connected with parameter p2103 "Acknowledge faults". 8 Enable speed controller The speed controller is enabled by setting this bit. The speed control is inhibited with a low signal. As a consequence, a travel command cannot be executed, however the motor remains magnetized. This signal must be connected with parameter p0856 "Speed controller enable". 9 Free 10 Master control by the PLC This bit must be set, otherwise no commands from the higherlevel control are accepted. This signal must be connected with parameter p0854 "Master control by PLC". 11 Free 12 Select, closed-loop speed / torque controlled operation 13 Free 14 Free 15 Free A changeover is made between closed-loop speed and torque control when this input is set. This signal must be connected with parameter p1501 "Changeover between closed-loop speed/torque control". Table 5-5 Control word_2 Bit Signal name Remarks 0 Select drive data set DDS bit 0 1 Select drive data set DDS bit Free By selecting drive data set, it is possible to toggle between different drive data sets by controlling bits "DDS bit 0" and "DDS bit 1". The signal "Select drive data set DDS bit0" must be connected with parameter p0820 "Drive Data Set selection DDS bit 0" and the signal "Select drive data set DDS bit1" must be connected with parameter p0821 "Drive Data Set selection DDS bit 1". Operating Instructions, 07/

54 Communication 5.2 Configuring the PROFIBUS connection Table 5-6 Application control word_1 Bit Signal name Remarks 0 Enable start pulse With the high signal, a torque setpoint specified from the S7 is set for a configurable time. This signal must be connected with the p22070 "boenablebrakestorevalue" parameter. 1 Enable setpoint/actual value monitoring With the high signal, the setpoint/actual value monitoring is activated in the DCC block OverSpeed. This signal must be connected with parameter p22038 "boenablesetpointactualmon". 2 Enable field weakening With the high signal, the drive is permitted to operate in field weakening above its rated speed. This signal must be connected with parameter p22132 "boenablefieldweak". 3 Reset load memory With the high signal, the load actual value saved in the DCC block LoadDependingFieldWeak is reset. This signal must be connected with parameter p22141 "boresetloadtorque". 4 Select speed limitation, bit 1 Two different speed limits can be selected using bit 1 and bit 5 Select speed limitation, bit 2 2. If bit 1 and bit 2 are not selected, then the maximum speed acts as limit. The "Select speed limit bit1" signal must be connected with parameter p22051 "bobit1limitspeed" - and the "Select speed limiting bit2" signal must be connected with parameter p22052 "bobit2limitspeed". 6 Select speed prelimit switch With the high signal, a changeover is made to the configured prelimit switch speed (approx. 5% of the maximum speed). This signal must be connected with parameter p22053 "boprelimitswitch" Free Communication SINAMICS SIMATIC Table 5-7 Process data SINAMICS SIMATIC PZD Signal name Remarks 1 Status_word_1 see below, Table "Status word_1" Parameter r2089[0] "Send binector-connector converter status word, Status word 1" must be connected with parameter p2051[0]. 2 Speed actual value The speed actual value (r0063) is sent, referred to the reference value. The reference value is the maximum value. nmax = nreference = nrated + nfw = 100 % 4000 hex = dec = 100 % Parameter r0063[0] "Actual speed value, unsmoothed" must be connected with parameter p2051[1]. 54 Operating Instructions, 07/2012

55 Communication 5.2 Configuring the PROFIBUS connection PZD Signal name Remarks 3 Status_word_2 See below, Table "Status_word_2" Parameter r2089[1] "Send binector-connector converter status word, Status word 2" must be connected with parameter p2051[2]. 4 Application_status_word_1 See below, Table "Application_status_word_1" Parameter r2089[2] "Send binector-connector converter status word, free Status word 3" must be connected with parameter p2051[3]. 5 Fault numbers The actual fault code is sent as word. Parameter r2131 "Current fault code" must be connected with parameter p2051[4]. 6 Smoothed total current actual value The current actual value smoothed (r0068[1]) is sent, referred to the reference value. The reference value is the maximum value. Imax = Ireference = Irated + IOverload = 100 % 4000 hex = dec = 100 % Parameter r0068[1] "Absolute current actual value" must be connected with parameter p2051[5]. 7 Load actual value The determined load actual value is sent (only for hoist, e.g.: kg or tons). The determined load value from 0 to 65,535 (UINT) is sent to the S7. The normalization factor for the load current in physical units (tons) must be parameterized in DCC block LoadDependingFieldWeak. Parameter r22157 "rloadwithnormfactor" must be connected with parameter p2051[6]. 8 Smoothed torque actual value The smoothed torque actual value (r0080[1]) is sent, referred to the reference value. The reference value is the maximum value. Mmax = Mreference = Mrated + MOverload = 100 % 4000 hex = dec = 100 % Parameter r0080[1] "Torque actual value" must be connected with parameter p2051[7]. 9 Alarm numbers The actual alarm code is sent as word. Parameter r2132 "Current alarm code" must be connected with parameter p2051[8] Free Application-related area Operating Instructions, 07/

56 Communication 5.2 Configuring the PROFIBUS connection Table 5-8 Status_word_1 Bit Signal name Remarks 0 Ready to be switched on If a high signal is available at the bit, then this means that the power supply is switched on and the electronics has been initialized. Parameter r0899 bit0 "Ready for switching on" must be connected with the binector-connector converter in parameter p2080[0]. 1 Ready If a high signal is available at the bit, then this means that voltage is connected to the Line Module. Parameter r0899 bit1 "Ready for operation" must be connected with the binector-connector converter in parameter p2080[1]. 2 Operation enable If a high signal is available at the bit, then this means that the electronics and the pulses have been enabled and the drive accelerates up to the setpoint that has been entered. Parameter r0899 bit2 "Ready for operation" must be connected with the binector-connector converter in parameter p2080[2]. 3 Fault active If a high signal is present at the bit, this indicates that the drive has a fault and is therefore non-operational. After acknowledgment and after the cause has been successfully removed, the drive goes into the switch-on inhibit state. Parameter r2139 bit3 "Fault present" must be connected with the binector-connector converter in parameter p2080[3]. 4 Coasting down active (OFF2) If a high signal is available at the bit, then this signifies that no OFF2 is active. Parameter r899 bit4 "No coasting active" must be connected with the binector-connector converter in parameter p2080[4]. 5 Quick stop active (OFF3) If a high signal is available at the bit, then this signifies that no OFF3 is active. Parameter r0899 bit5 "No quick stop active" must be connected with the binector-connector converter in parameter p2080[5]. 6 Switch on inhibit If a high signal is available at the bit, then this signifies that a restart is only possible using OFF1 followed by ON. Parameter r0899 bit6 "Switching on inhibited active" must be connected with binector-connector converter in parameter p2080[6]. 7 Alarm active If a high signal is available at the bit, then this means that the drive is in operation again and acknowledgment is not required. Parameter r2139 bit7 "Alarm present" must be connected with the binector-connector converter in parameter p2080[7]. 8 Speed setpoint-actual value deviation within the tolerance range If a high signal is available at the bit, then this means that the actual value is within the tolerance range. Parameter r2197 bit7 "Speed setp act val deviation in tolerance t_off" must be connected with the binectorconnector converter in parameter p2080[8]. 9 Control request to PLC If a high signal is available at the bit, then this means that the automation system is requested to accept master control. Parameter r0899 bit9 "Control requested" must be connected with the binector-connector converter in parameter p2080[9]. 56 Operating Instructions, 07/2012

57 Communication 5.2 Configuring the PROFIBUS connection Bit Signal name Remarks 10 f or n comparison value reached or exceeded 11 I, M or P limit reached or exceeded If a high signal is available at the bit, then this means that the f or n comparison value has been reached or exceeded. Parameter r2199 bit1 "f or n comparison value reached or exceeded" must be connected with the binector-connector converter in parameter p2080[10]. If a high signal is available at the bit, then this means that the I, M or P limit has not been reached or was exceeded. Parameter r1407 bit7 "Torque limit reached" must be connected with the binector-connector converter in parameter p2080[11]. 12 Holding brake open If a high signal is available at the bit, then this means that the holding brake is activated. Parameter r0899 bit12 "Holding brake open" must be connected with the binector-connector converter in parameter p2080[12]. 13 No motor overtemperature alarm If a high signal is present at the bit, this indicates that the ramp-function generator is active. 14 n_act >= 0 If a high signal is available at the bit, this means that the speed setpoint 0. Parameter r2197 bit3 "n_act >=0" must be connected with the binector-connector converter in parameter p2080[14]. 15 No alarm, thermal power unit overload If a high signal is present at the bit, this indicates that there is no alarm due to thermal overload of the drive converter. With a low signal an alarm is present due to thermal overload of the power unit. Parameter r2135 bit15 "Alarm power unit terminal overload" must be connected with the binector-connector converter in parameter p2080[15]. Operating Instructions, 07/

58 Communication 5.2 Configuring the PROFIBUS connection Table 5-9 Status_word_2 Bit Signal name Remarks 0 Drive data set DDS active, bit 0 1 Drive data set DDS active, bit 1 The active drive data set bit 0 is signaled back using the high signal. Parameter r0051 Bit0 "Drive Data Set DDS effective, bit 0" must be connected with the binector-connector converter in parameter p2081[0]. The active drive data set bit 1 is signaled back using the high signal. Parameter r0051 bit1 "Drive Data Set DDS effective, bit 1" must be connected with the binector-connector converter in parameter p2081[1]. 2-9 Free 10 Upper torque limit active The active upper torque limit is signaled back using the high signal. Parameter r1407 bit8 "Upper torque limit active" must be connected with the binector-connector converter in parameter p2081[10]. 11 Lower torque limit active The active lower torque limit is signaled back using the high signal. Parameter r1407 bit9 "Lower torque limit active" must be connected with the binector-connector converter in parameter p2081[11] Free Table 5-10 Application_status_word_1 Bit Signal name Remarks 0 Torque set The set torque for the duration of the output signal r22078 "bosettorque" is signaled back using the high signal. Parameter r22078 bit0 "bosettorque" must be connected with the binector-connector converter in parameter p2082[0]. 1 Current distribution monitoring responded With the high signal, the current distribution monitoring has responded. Parameter r22097 bit0 "bofaultcurrentmonitoring" must be connected with the binector-connector converter in parameter p2082[1]. 2 Field weakening enabled With the high signal, field weakening has been enabled. Parameter r22158 bit0 "booutenablefieldweak" must be connected with the binector-connector converter in parameter p2082[2]. 3 Overspeed monitoring responded 4-15 Free With the high signal, the overspeed monitoring has responded. Parameter r22041 bit0 "booverspeed" must be connected with the binector-connector converter in parameter p2082[3]. 58 Operating Instructions, 07/2012

59 Communication 5.3 Configuring the I/O connection 5.3 Configuring the I/O connection A solution with terminals (analog input, digital inputs and digital outputs) is shown in the following for basic single-axis crane operation without using a higher-level control. Note With the execution of the script from the selection screen, the I/O connection automatically interconnects to the correct parameters; refer to the table below and Section Standard application, SingleAxis (Page 90). Note When using multi-motor operation for gantry or trolley, each motor is monitored using its own circuit breaker. For each drive group, the monitoring function is connected in series, i.e. for a voltage of 24 V everything is OK - and for a voltage of 0 V, then the monitoring function has responded. The monitoring signal is connected to the onboard digital inputs of the SINAMICS Control Unit. To shut down the relevant drive group, this monitoring signal is connected to OFF2. As soon as the monitoring function trips the circuit breaker, then this drive group is shut down with OFF2. Example of a distributed single-axis solution with 1 CU for each axis: SINAMICS CU1 digital input 10 (X121.10) group Trolley_1 SINAMICS CU2 digital input 10 (X121.10) group Trolley_2 SINAMICS CU3 digital input 10 (X121.10) group Gantry_1 SINAMICS CU4 digital input 10 (X121.10) group Gantry_2 Operating Instructions, 07/

60 Communication 5.3 Configuring the I/O connection Table 5-11 Pre-assignment of the analog input, digital inputs and digital outputs of the CU310-2 Terminal Signal name Remarks DI0 = X121.1 DI1 = X121.2 DI2 = X121.3 DI3 = X121.4 DI8 = X121.7 DI9 = X121.8 DI10 = X DI11 = X DI12 = X DI13 = X DO14 = X DO15 = X AI0+ = X AI0- = X DI16 = X Speed specification 1; positive direction Speed specification 1; negative direction Speed specification 2 / free Speed specification 3 / free Speed specification 4 / free ON / OFF1 OFF2 Acknowledge fault Enable start pulse Enable setpoint / actual value monitoring Fault active Open brake Analog master switch setpoint Free / EP terminal Speed specification 1; positive direction of rotation specification. Control Unit p21501 = r722.0 Drive Object p22002 = r722.0 Master switch deflected in the positive direction. Speed specification 1; negative direction of rotation specification. Control Unit p21502 = r722.1 Drive Object p22003 = r722.1 Master switch deflected in the negative direction. Speed specification 2 / free Control Unit p21503 = r722.2 Speed specification 3 / free Control Unit p21504 = r722.3 Speed specification 4 / free Control Unit p21505 = r722.4 The drive is switched on and off using ON / OFF1. Drive Object p840 = r722.8 OFF2 must be set, otherwise the drive cannot be switched on. If input OFF2 is withdrawn when the drive is switched on, the pulses must be inhibited and the motor coasts down. Drive Object p844 = r722.9 When this input is set, any pending fault is acknowledged as soon as the fault cause has been remedied. Drive Object p2103 = r With a high signal, a constant torque setpoint or a torque setpoint issued from the S7 as a function of the load is set for a configurable time. Drive Object p22070 = r A high signal activates the setpoint / actual value monitoring in the DCC_OverSpeed block. Drive Object p22038 = r If a high signal is present at the bit, this indicates that the drive has a fault and is therefore non-operational. The drive switches to "switch-on inhibited" once the fault has been acknowledged and the cause has been remedied. Control Unit p744 = r A high signal present at the bit indicates that the brake must be opened. Control Unit p745 = r The master switch setpoint is specified in the range from 0 to 10 V. Drive Object p22000 = r752 This input is used as EP terminal for activated Safety Integrated Basic Functions. 60 Operating Instructions, 07/2012

61 Communication 5.3 Configuring the I/O connection Terminal Signal name Remarks DI17 + = X DI17 - = X Free / EP terminal This input is used as EP terminal for activated Safety Integrated Basic Functions. DI18 = X DI19 + = X DI19 - = X DI20 = X DI21 + = X DI21 - = X DI22 + = X DI22 - = X D016 = X Enable field weakening Reset load memory Select speed limitation, bit 1 Select speed limitation, bit 2 Select speed prelimit switch Overspeed active / free A high signal permits the drive to operate beyond its rated speed in field weakening. Drive Object p22132 = r The high signal resets the actual load value saved in the LoadDependingFieldWeak DCC block. Drive Object p22141 = r Two different speed limits can be selected using bit 1 and bit 2. If bit 1 and bit 2 are not selected, then the maximum speed acts as limit. Bit 1: Drive Object p22051 = r Bit 2: Drive Object p22052 = r A high signal is used to switch to the configured prelimit switch speed (approx. 5% of the maximum speed). Drive Object p22053 = r A high signal at this bit means that the speed controller is active. Control Unit p746 = r22041 Operating Instructions, 07/

62 Communication 5.3 Configuring the I/O connection Figure 5-3 CU310-2 pre-assignment in standard applications 62 Operating Instructions, 07/2012

63 Commissioning 6 NOTICE The polarity rules must be paid attention to: Hoisting gear: Hoisting speed is POSITIVE, with ascending position values. Lowering speed is NEGATIVE, with descending position values. Long travel: Travel to the right, POSITIVE speed with ascending position values. Travel to the left, NEGATIVE speed with descending position values. Trolley: Travel towards the ship, POSITIVE speed with ascending position values. Travel towards the shore, NEGATIVE speed with descending position values. 6.1 General information The scope of delivery is described in the chapter titled System overview (Page 7). The CD contains several archived projects (ZIP format) with a SINAMICS CU310-2 and the cranes DCC blocks. Using a project from the CD 1. Copy the archived project from the CD to the hard disk. 2. Dearchive the project (unzip). 3. Import the project into STARTER using XML import. 4. The imported project can be used as basis for the application. Transferring DCC blocks into the customer application project If a customer application project already exists, then you can take the cranes DCC blocks from one of the projects archived on the CD. To do so, proceed as follows: 1. Execute the steps 1. to 3. as described above. 2. Open both of the projects in STARTER (the project imported into STARTER and the customer application project). 3. Copy the blocks of the imported project into the Windows clipboard. 4. Insert the DCC blocks into the customer application project. 5. This means that these DCC blocks are now also available in the customer application project. Operating Instructions, 07/

64 Commissioning 6.1 General information Further, the CD also contains standard applications for various crane types (see Chapter Standard applications and adaptation options (Page 89)). We recommend the following procedure for commissioning a SINAMICS drive. Figure 6-1 Overview of the commissioning The user can open the appropriate standard application using STARTER. The following data needs to be checked and adapted if necessary: Motor Module data in the drive object Motor and encoder data in the drive object Reference data in the drive object Execution of script files for the relevant drive object 64 Operating Instructions, 07/2012

65 Commissioning 6.1 General information Crane-specific technologies (DCC): Adaptation of the master switch curve in the DCC block MasterSwitch Adaptation of the torque-speed characteristic in the DCC block LoadDependingFieldWeak Adaptation of the rated speed (rratedspeed) in the DCC blocks Adaptation of the prelimit switch speed in the DCC block PreLimitSwitch etc. The adapted standard application must be loaded to the CompactFlash (CF) card, once all necessary settings have been successfully made. When commissioning has been completed, a RAM to ROM store operation must be performed to ensure that the user program is copied to the CF card for retentive storage. Communication via PROFIBUS between the S7 and SINAMICS is preconfigured in the standard projects; further information can be found in the chapter titled Communication (Page 47). The commissioning procedure is described below. Before users start the commissioning procedure, they should ensure that the motor data and encoder data in the SINAMICS drive object match those of their real system. This should be checked in the configuration data of the SINAMICS drive object (refer to following diagram). The user also has to ensure that the reference speed (p2000) and maximum speed (p1082) for SINAMICS match the reference speed and maximum speed for SIMATIC. In SINAMICS, the reference parameters p2000 to p2003 must be checked. Operating Instructions, 07/

66 Commissioning 6.2 Controlling the crane taking the PROFIdrive profile into account Figure 6-2 Configuration file DO Hoist_1 6.2 Controlling the crane taking the PROFIdrive profile into account The control of the drive is now subsequently shown in an example; for more detailed information see Ref. [6] Switch on the drive The drive is switched on as follows: Select OFF2 and OFF3. OFF2 and OFF3 checkback signals are output after one program cycle. "Ready to power up" is also output. These signals switch OFF1. After one further cycle, "Ready" is signaled. 66 Operating Instructions, 07/2012

67 Commissioning 6.2 Controlling the crane taking the PROFIdrive profile into account The drive command, the pulse enable, and the speed controller enable magnetize the motor. As soon as magnetization is complete, operation is enabled and the brake is released. If "Brake released" is signaled back, the ramp-function generator and the setpoint can be enabled. A "positive" or "negative" command causes the drive travel to start after one program cycle and a signal is sent back indicating that the axis is in motion. Figure 6-3 Start the drive Operating Instructions, 07/

68 Commissioning 6.2 Controlling the crane taking the PROFIdrive profile into account Switch off the drive The drive is switched off as follows: Cancel the "positive" or "negative" command and the travel task. Once the ramp-down time has elapsed, the checkback signals "Direction of travel "positive" or "negative" and f or n comparison value reached or exceeded are reset. The brake closes. When the "Brake closed" message is output, the pulse enable is canceled. After one program cycle, a low signal is issued back at "Enable operation" and OFF1 is canceled. After one further cycle, the drive is no longer ready to start. Deactivating OFF2 and OFF3 disables the ready to start condition and checkback signals OFF2 and OFF3 change to the low level. Figure 6-4 Stop the drive 68 Operating Instructions, 07/2012

69 Commissioning 6.3 SINAMICS drive object Mechanical motion stop The S7 transmits the signal "Mechanical stop". At the same time, the commands OFF2, "Close brake", "Disable ramp-function generator", and "Inhibit pulse enable" are activated. Figure 6-5 Mechanical stop 6.3 SINAMICS drive object Basic procedure 1. Enter the motor data according to the rating plate. 2. Enter the following motor values for any number (n_items) of motors connected in parallel: Rated voltage: p0304 Vrated Rated current: p0305 Irated n_units Rated power: p0307 Prated n_units Rated power factor: p0308 cos_φrated Rated efficiency: p0309 ηrated Rated frequency: p0310 frated Rated speed: p0311 nrated 3. In order to set the motor model as accurately as possible, enter the SINAMICS parameters p0230, p0233 and p0235 for each motor in accordance with the system configuration. Note If this value is incorrectly preset for a motor with a separate winding system, extreme torque surges will occur when the drive is switched on. Operating Instructions, 07/

70 Commissioning 6.3 SINAMICS drive object 4. Determine the total cable resistance (Motor Module to motor) for each motor and enter the result in SINAMICS parameter p Enter the motor series reactor (if installed) in SINAMICS parameter p0353. Stationary measurement After having checked all of the prerequisites, carry out a stationary measurement in SINAMICS for each Motor Module (i.e. hoist, gantry, trolley, etc.). Note Prior to the standstill measurement: After having entered all data, go online to the corresponding drive object and verify the data specified above or adapt it accordingly. Initially set SINAMICS parameter p0340 to a value of 2. After parameter p0340 has returned to 0, it must be set again to a value of 3. The following values are determined in the stationary measurement: Equivalent circuit diagram data Stator resistance Leakage inductances IGBT forward voltage or compensation for the IGBT interlock times Tips after the stationary measurement In operation, check the flux actual value: With the correct rating plate data and successfully set MOT ID, the actual flux value (r0084) is 100% and below field weakening. Check over the complete speed range up to field weakening, e.g. while accelerating. If a rotating measurement cannot be performed, if necessary, manually correct the magnetizing current and magnetizing inductance: Correct the rated magnetizing current (p0320) until an actual flux value (r0084) of 100% is reached over the entire speed range up to field weakening. If the rated magnetizing current is still not correct, then deviations will be visible - especially in the range up to 30% nrated. If the drive can be rotated freely (without load or with only slight load), the correct value of the magnetizing current (r0029) can be read-out when operating in the speed range 60% nrated up to 80% nrated and entered in p Operating Instructions, 07/2012

71 Commissioning 6.3 SINAMICS drive object The magnetizing inductance (p0360) cannot be corrected directly. The drive keeps the product p0320 p0360 (rated flux) constant and changes p0360 depending on p0320. The value r1787 = 0 is displayed (correction value Lh adaptation) if the correct rated magnetizing current was set (p0320). Note After having carried out the standstill measurement, do not forget to copy RAM data to ROM and to transfer all of the data to the offline project. To do this, select Upload to PG and then save. Note The stationary measurement is available in the Project Navigator under SINAMICS Drive object (e.g. Hoist_1) in the menu item Commissioning. Figure 6-6 Stationary measurement Operating Instructions, 07/

72 Commissioning 6.3 SINAMICS drive object Checking the direction of rotation After the stationary measurement has been successfully completed, then the direction of rotation should first be checked. If the motors have still not been installed, the SINAMICS control panel should be used to check the direction of rotation. Otherwise, the direction of rotation should be checked via the PLC (S7) or via terminals (I/O) - i.e. when the motor is rotating in the positive direction. The encoder must then supply positive values. If it is no longer possible to interchange the phases, the direction must be reversed in SINAMICS using parameter p1821. Please note that for several drive data sets with different motors, this change must be made for all of the data sets involved. Note You can find more detailed information about using the control panel in Chapter 4.3 "Using the operator control panel" in document Ref. [4]. Rotating measurement The rotating measurement with speed controller optimization should then be carried out. The rotating measurement function should only be initiated if the motor can freely rotate. Otherwise, it is not permissible that this function is executed. The following values are determined in the rotating measurement: The magnetizing characteristic is measured The magnetizing current is measured The speed controller is optimized The acceleration pre-control is set The ratio between the total moment of inertia and the motor is set 72 Operating Instructions, 07/2012

73 Commissioning 6.3 SINAMICS drive object Figure 6-7 Rotating measurement If the rotating measurement cannot be initiated, then the speed control loop should either be optimized by re-calculating the control parameters or manually using the controller. If the moment of inertia was entered, the control parameters are calculated using the automatic parameterization (p0340 = 4). The controller parameters are defined in accordance with the symmetrical optimum as follows: Tn = 4 Ts Kp = 0.5 r0345 / Ts Kp = 2 r0345 / Tn (Ts = total of short deceleration times) Sum of the short deceleration times, vector operation with encoder: Speed actual value smoothing time p1441 and speed controller, speed actual value smoothing time p1442 Sum of the short deceleration times, vector operation without encoder: Speed controller, speed actual value smoothing time p1452 Note As a general rule, the lowest possible actual speed smoothing values should be selected for normal operation. When the encoders are well shielded, a smoothing value of 0 can be entered. If a setting of 0 is entered, the above formulas no longer apply. In this case, Tn should be set to 0, Kp so that there is no overshoot, and then Tn increased until the desired controller performance is obtained. Operating Instructions, 07/

74 Commissioning 6.3 SINAMICS drive object If oscillation develops with these settings, reduce the speed controller gain Kp manually. Actual speed value smoothing can also be increased (standard procedure for gearless or high-frequency torsional oscillation) and the controller calculation performed again because this value is also used to calculate Kp and Tn. The following relationships apply for optimization: If Kp is increased, the controller becomes faster and overshoot is increased. If Tn is reduced, the controller also becomes faster and the overshoot is also increased. When setting the speed control manually, the simplest approach is to first define the dynamic response via Kp (and actual speed value smoothing), so that the integral time can be subsequently reduced as much as possible. When doing this, the closed-loop control must also remain stable in the field-weakening range. Reducing the controller gain will generally dampen any oscillations in the closed-loop speed control. Another possible option is to increase the smoothing time in p1452. However, the accuracy of the control will diminish if smoothing is set too high. The integral output of the speed controller can be monitored via r1482 and the limited controller output (torque setpoint) via r1508. Tips regarding speed optimization Adjusting the switchover from current model ("open-loop controlled") to voltage model ("closed-loop controlled"): p1752 = 300 [rpm]: Switchover speed p1756 = 20 [%]: Hysteresis These two values have proven themselves to be useful in practice, however, they can be adapted as required. Complete commissioning by operating the drive across the entire speed range and checking that operation is smooth in order to exclude universal shaft/gear problems. The trolleys excite the natural resonance of the crane structure when the speed changes quickly. This is not in the control loop of the trolley; but represents the reference system. To prevent damage caused by excited oscillations: Kp low, Tn high, adaptation The integrator has a tendency towards saturation which leads to overshoot of the end position and subsequent retraction 74 Operating Instructions, 07/2012

75 Commissioning 6.4 Cranes DCC blocks Acceleration precontrol for the known mass Problem: Mass varies with/without load (e.g. container); precontrol with approx % With precontrol, relieve the I component as far as possible: Also observe r1482; r1481; r0080 and r0078 in the trace. The precontrol function is available in the Project Navigator under the SINAMICS Drive object (e.g. Hoist_1) in the menu item Open-loop/closed-loop control > speed setpoint filter > Precontrol The precontrol function can be set accordingly using p0342 Ratio of total/motor moment of inertia and p1496 Acceleration precontrol scaling Setpoint/actual value smoothing balancing Actual value smoothing should be kept to a minimum; high values increase overshoot - setpoint smoothing provides a more constant velocity due to the motion profile (master switch setpoint) 6.4 Cranes DCC blocks The DCC blocks must be configured for the various tasks; also see Chapter DCC blocks (Page 21). MasterSwitch block The master switch curve must be configured if the DCC_MasterSwitch block is used. PreLimitSwitch block The speed limits must be adapted in the DCC_PreLimitSwitch block. CurrentDistribution block (relevant for trolley and hoisting gear) The deceleration time and the parameter threshold must be adapted as required in the DCC_CurrentDistribution block. StartPulse block (only relevant for hoist) The I component of the speed controller is saved in the DCC_StartPulse block when the "Close brake" command is issued. When the "Release brake" command is issued, the speed controller is set with this saved I component. LoadDependingFieldWeaking block (only relevant for hoist) The load-dependent curve must be entered in the DCC_LoadDependingFieldWeaking block and the factors must be determined in the commissioning phase; refer to Function (DCC block) "Load-dependent field weakening" (Page 76). OverSpeed block When required, the parameter threshold is adapted in the DCC_OverSpeed block in order to identify an overspeed condition. Operating Instructions, 07/

76 Commissioning 6.5 Function (DCC block) "Load-dependent field weakening" 6.5 Function (DCC block) "Load-dependent field weakening" For closed-loop control drives in various operating situations an attempt is made to increase the speed above the rated speed. This is used, for example, for hoisting gear of cranes to increase the handling capacity. However, the maximum speed in the rated speed range that can be achieved at rated flux is determined by the maximum permissible voltage. This means that an increase above this speed cannot be achieved by increasing the voltage; both for DC and also AC drives, this is only possible using field weakening. However, with field weakening the available torque is reduced. This means that field weakening is only possible if also a reduced torque is demanded. For a hoisting gear, this is e.g. only possible for partial loads that are less than the rated load. The permissible speed ω for the (maximum) rated power P = PN for this speed increase is determined using P = M ω in the rated speed range at initially constant flux dependent on the required torque. In this case, the upper speed limit is the maximum permissible speed for the motor. A measure for required load torque in the rated speed range is the current in the steadystate phase, which is directly proportional to load torque. The DCC block calculates the steady-state (static) component of the torque, which must be provided for the prevailing torque from the total torque in the rated speed range. The total torque is then corrected to take into account the frictional torque, which then results in the torque that is available for the load. For reasons of accuracy, the arithmetic mean value is used for the calculation. Further, dependent on the calculated torque, the permissible speed setpoint for field weakening for P = PN is generated using the motor power characteristic Theoretical basics and equations The steady-state load torque is calculated using the following torque equation. Mmotor = Mload + Mfriction Mmotor : Motor torque Mload : Load torque (this is required) Mfriction : Frictional torque WARNING This setting should only be carried out by qualified personnel. Particular attention must be paid to the reduced breakdown torque of the motor in the field weakening range. Add a safety margin to the data provided by the machine manufacturer. 76 Operating Instructions, 07/2012

77 Commissioning 6.5 Function (DCC block) "Load-dependent field weakening" Commissioning instructions Generating the measured variables Sufficient measurements must be made in order to obtain a realistic value when determining the average torque in the constant speed phase. The arithmetic average value is generated by integrating all of the values obtained in a measuring window in the constant speed phase. This constant speed must be pending for the time parameterized in p22161 "rdetectionconstmove" after which the torque calculation is started. The input at the p22161 parameter is limited to minimum 100 ms in order to reliably detect a constant speed. The number of measurements can be read-out in "rcountsmeasurrange". For a new measurement, at standstill, the old measurement must be deleted (the measurement is deleted using a positive edge at "boresetloadtorque"), otherwise, no new load and no new field weakening speed are determined. If the old measurement is not deleted, then the values last determined are available at the output of the DCC block. For the hoisting direction, the following always applies: Acceleration must be POSITIVE (100% at the rated acceleration time). The actual speed value must be POSITIVE (100% at the field weakening speed). Current actual value (100% at the rated motor current) must be POSITIVE. Note If a new measurement is to be made, then it is absolutely necessary that a positive edge is applied to connection "boresetloadtorque". Operating Instructions, 07/

78 Commissioning 6.5 Function (DCC block) "Load-dependent field weakening" Table 6-1 Parameter number Standard assignment of the setting connections before commissioning Name Value Description p22134 rloadnormfactor 1.0 Adaptation factor to convert into a physical quantity The conversion is made using the formula: Load[t] = measured value * rloadnormfactor + raddtorquebeforepli p22138 rtorquesmoothtime 120 ms Smoothing time for the torque [ms] Rough order of magnitude: 0 ms 200 ms p22139 raddtorquebeforepli 0.0 Offset to determine the load: Load[t] = measured value * rloadnormfactor + raddtorquebeforepli p22142 refficiency_eta 100 % Adaptation factor (referred to the rated load) for the difference in efficiency when raising and lowering Rough order of magnitude: 110 % % p22143 rfrictiontorque 0.0 % Frictional component (referred to the rated load) for the torque Rough order of magnitude: 1 % - 3 % This corresponds to the torque value to be compensated p22161 rdetectionconstmove 250 ms Delay time for constant-speed detection [ms]; values less than 100 ms are not accepted Note The orders of magnitude listed in the above table are guide values only. Table 6-2 Parameter number Important outputs of the DCC block for commissioning Name Value Description r22156 routspeedsetpoint - Speed setpoint logically combined with the master switch setpoint r22157 rloadwithnormfactor - Evaluated load actual value r22158 booutenablefieldwea - Enable field weakening k r22159 raddsetpointafterpli % Supplementary speed setpoint with offset relative to "rreferencespeed" after motor curve r22160 rcountsmeasurerange - Number of sampling operations for the measurement 78 Operating Instructions, 07/2012

79 Commissioning 6.5 Function (DCC block) "Load-dependent field weakening" Compensating the frictional torque Mmotor = Mload + Mfriction Setting instructions Note If at all possible, perform the measurements with the motor in a warm state with warm gearbox oil. 1. Move the empty drum at constant rated speed (nrated) in the hoisting direction. 120 ms has proven itself as a good value for parameter p22138 "rtorquesmoothtime". However, this value can be individually adapted. 2. In parameter r0079 "rtorquesetpointtotal" read the frictional torque and convert the absolute value into a percentage, taking into account the reference torque in parameter p2003. The calculation is made according to the following formula: p22143 [%] = (r0079 [Nm] x 100 [%]) / (p2003 [Nm]) 3. Repeat your measurement in the hoisting direction. 4. Enter the mean value (approx. 1 % to 3 %) into parameter p22143 "rfrictiontorque". This means that the frictional current will be taken into account at the output, parameter r22157 "rloadwithnormfactor" Correcting the efficiency The efficiency correction is used to ensure that with the same load, the velocity when lowering is identical to the velocity when hoisting (raising). For hoisting and lowering, in order to determine the same load actual value at different current values, it is necessary to multiply the value present when lowering in the parameter r22157 "rloadwithnormfactor" by the factor 1/η 2. The setting is made with parameter p22142 "refficiency_eta". Parameter r22157 "rloadwithnormfactor" should neither change when hoisting nor when lowering. As a result, the efficiency correction value will always be 100% for hoisting and 100 % for lowering. This will be illustrated in the following calculation as example. Operating Instructions, 07/

80 Commissioning 6.5 Function (DCC block) "Load-dependent field weakening" Example calculation Saved value with the rated load, hoisting: Parameter r22157 "rloadwithnormfactorhoisting = 98 % Saved value with the rated load, lowering: Parameter r22157 "rloadwithnormfactorlowering = 82 % Calculated value (refficiency_eta) = % Setting instructions Move the rated load in the hoisting direction and then in the lowering direction at constant rated speed (nrated motor), assuming refficiency_eta = 100% (default setting) repeat this measurement several times. And note down the mean values of " rloadwithnormfactorhoisting" and " rloadwithnormfactorlowering". Calculate the refficiency_eta corresponding to the specified example. Note Apply a positive edge at input "boresetloadtorque" after every measurement. Check the settings by hoisting and lowering the rated load (up to the rated speed) several times. In so doing, parameter r22157 "rloadwithnormfactor" should no longer change when hoisting and lowering. Adapt the factor in parameter p22142 "refficiency_eta" (approx. 115 %) to keep the change between hoisting and lowering as low as possible. Note When lowering, if a load higher than the actual load is determined, a higher value of "rloadwithnormfactor" while lowering with respect to hoisting ensures that the drive is not overloaded when braking the load. This setting is only necessary for the case where the load should be determined while lowering (e.g. when starting with lowering). For normal applications, it is sufficient if the determined load is only re-calculated again if the load has changed. Normally, this is only possible after the spreader has taken-up a new load. This means that the signals "Twistlocks open" and "Twistlocks closed" can be used to set a positive edge of the signal "boresetloadcurrent". This allows the load to be recalculated. 80 Operating Instructions, 07/2012

81 Commissioning 6.5 Function (DCC block) "Load-dependent field weakening" Calculating the physical size of the load The determined load can be converted to a physical quantity (e.g. tons) using connections "rloadnormfactor" and "raddcurrentbeforepli". Calculation example: When hoisting a rated load of 45 t, "rloadwithnormfactor" indicates a value of 85 %. A constant load can be added (e.g. in tons) using "raddtorquebeforepli" Criteria for enabling field weakening Field weakening is not enabled or is inhibited as long as parameter p22132 "boenablefieldweak" is set to false. While field weakening is not enabled, the master switch setpoint is limited to the rated speed. As soon as field weakening is enabled (parameter r22158 "booutenablefieldweak" = True), the master switch setpoint is limited to the calculated load-dependent speed setpoint. The criteria to enable field weakening dependent on the speed actual value and speed setpoint are described in the following: The speed setpoint in parameter p22130 "rinspeedsetpoint" is interrogated at the input of the DCC block for a value greater than 95% of the reference speed (parameter p22136 "rreferencespeed"). The speed actual value in parameter p22131 "ractualspeed" is interrogated at the input of the DCC block for a value greater than 90% of the rated speed (parameter p22135 "rratedspeed"). The input in parameter p22132 "boenablefieldweak" must be set. This constant speed must be pending for the time parameterized in p22161 "rdetectionconstmove" after which the torque calculation is started. The input at the p22161 parameter is limited to minimum 100 ms in order to reliably detect a constant speed. Load determination is only started if the conditions mentioned above are fulfilled. As soon as this operation has been completed, field weakening is enabled and the speed setpoint is increased corresponding to the configured motor characteristic. Operating Instructions, 07/

82 Commissioning 6.5 Function (DCC block) "Load-dependent field weakening" Load curves in examples If current values were converted into a physical quantity using parameter p22134 "rloadnormfactor", then the value "Load (Nm)" is directly specified in tons instead of like before as a percentage of the torque. See the following tables Example 1: Constant power Figure 6-8 Load-dependent field weakening, example 1 Load (X) Speed (Y) p22144 "X1" = 50 % p22145 "Y1" = 100 % p22146 "X2" = 60 % p22147 "Y2" = 83.3 % p22148 "X3" = 70 % p22149 "Y3" = 71.4 % p22150 "X4" = 80 % p22151 "Y4" = 62.5 % p22152 "X5" = 90 % p22153 "Y5" = 55.5 % p22154 "X6" = 100 % p22155 "Y6" = 50 % 82 Operating Instructions, 07/2012

83 Commissioning 6.5 Function (DCC block) "Load-dependent field weakening" WARNING If excessively high torque values occur during constant-velocity travel, then the speed (Y2-Y5) must be reduced. The initial points for load or speed (X1 or Y1) as well as end points X6 and Y6 are fixed. The intermediate load points (X2-X5) can assume any values. The corresponding intermediate values for speed (Y2-Y5) are calculated according to the formula above. We recommend that the first points along the curve are selected close to one another as the speed is inversely proportional to the load. If a linearized motor curve is used, it must be ensured that the points along the motor curve (X1 to X6; Y1 to Y6) lie below the motor curve for constant power Example 2: Curve is specified (no constant power) This example is valid under the following conditions: It is not possible to utilize the motor power. The customer has supplied a load curve which specifies his technical requirements T Speed 100 % T Speed, refer to the curve supplied by the customer T Speed 50 % The current required to hoist 40 tons at rated speed (no field weakening) must first be determined. The current is directly proportional to the load. If, for a load of 40 tons, a current of 86% is measured, then for a 15 ton load the current should be 32% The curve can be calculated using the following formula: n: Speed Q: Load X: Constant Y: Constant With the data used above: equating to Operating Instructions, 07/

84 Commissioning 6.5 Function (DCC block) "Load-dependent field weakening" Result after inserting (constant): X = and Y = Figure 6-9 Load-dependent field weakening, example 2 Load (X) Speed (Y) p22144 "X1" = 32 % p22145 "Y1" = 100 % p22146 X2" = 45 % p22147 "Y2" = 77.0 % p22148 "X3" = 55 % p22149 "Y3" = 66.7 % p22150 "X4" = 65 % p22151 "Y4" = 59.6 % p22152 "X5" = 76 % p22153 "Y5" = 53.9 % p22154 "X6" = 86 % p22155 "Y6" = 50.0 % 84 Operating Instructions, 07/2012

85 Commissioning 6.5 Function (DCC block) "Load-dependent field weakening" WARNING If excessively high current values occur during constant-velocity travel, then the speed (Y2-Y6) must be reduced. The initial points for load or speed (X1 or Y1) as well as end points X6 and Y6 are fixed. The intermediate load points (X2-X5) can assume any values. The corresponding intermediate values for speed (Y2-Y5) are calculated according to the formula above. We recommend that the first points along the curve are selected close to one another, as the speed is inversely proportional to the load and to the offset. If a linearized motor curve is used, it must be ensured that the points along the motor curve (X1 to X6; Y1 to Y6) lie below the motor curve for constant power. Operating Instructions, 07/

86 Commissioning 6.6 The trace function 6.6 The trace function The trace function can be used to record measured values over a defined period depending on trigger conditions. The trace function is parameterized and operated via the parameterization and commissioning tool STARTER. Note Please refer to the STARTER online help for more information about parameterizing and operation. Up to eight recording channels per recorder Device clock cycles of SINAMICS S120 trace for single traces and endless trace: 4 channels: ms (Vector) 8 channels: 4 ms (Vector) It is possible that time slice 4 ms may not be available due to the system property. In this case, the next higher time slice is used. Two independent trace recorders per Control Unit Endless trace After the last trace parameters have been written to, the drive automatically starts again from the beginning with writing into the trace memory (ring buffer function). Triggering Without triggering (recording immediately after start) Triggering on signal - either signal edge or signal level Trigger delay and pretrigger possible STARTER parameterization and commissioning tool Automatic or adjustable scaling of display axes Signal measurement via cursor Adjustable trace cycle: Integer multiples of the basic sampling time Averaging the trace values If a float value is recorded with a cycle which is slower than the device cycle, the values recorded will not be averaged. This is achieved using parameter p4724. Parameter p4724[0...1] "Trace averaging in the time range" is set to "0" in the basic setting. Indices "0" and "1" stand for the two trace recorders, each with eight channels. Parameter p4724 must be set to "1" if the values that have been recorded are to be averaged. 86 Operating Instructions, 07/2012

87 Commissioning 6.6 The trace function Recording DCC input and output parameters The DCC input and output parameters can be recorded using the trace function. Ensure that you select the drive object (e.g. Hoist_1). All parameters of this drive object can then be seen. The DCC output parameters of the individual blocks can also be seen, and can be recorded using the trace function. In, in the DCC speed setpoint channel, several output parameters from DCC blocks are connected with the input of the subsequent DCC block - and therefore have the same value as the inputs of the following block. As a consequence, these output parameters can be recorded as input of the following (downstream) block. Figure 6-10 Trace signal selection Example for Hoist_1: For hoist applications, the output of the MasterSwitch (r22016) DCC block must be interconnected with the input of the DCC_LoadDependingFieldWeak (p22130) block. By recording output parameter r22016 then the input value for input p22130 is also automatically recorded. Operating Instructions, 07/

88 Commissioning 6.6 The trace function 88 Operating Instructions, 07/2012

89 Standard applications and adaptation options 7 The standard applications and adaptation options are described in this chapter. DCC chart expansion, data units, scaling data received from the control and changing a parameter type are described in the adaptation options. Delivery of the projects is described in the standard applications. The following table lists the standard applications included in the scope of supply. These serve as a starting basis for Ready-to-Run as well as Ready-to-Apply applications. Users can copy the standard applications from the CD supplied to a hard disk. The project must then be dearchived (unzipped) and imported into the STARTER engineering tool using XML import. Table 7-1 Standard applications Project Function module Number of axes Control Master switch type Control mode Control Unit SingleAxis Adaptation DriveAxis Hoist or Gantry or Trolley 1 PROFIBUS DP or terminals (I/O) Analog or digital Closed-loop speed control CU310-2 SingleAxis master-slave torque control Hoist_1 Hoist_2 2 PROFIBUS DP or terminals (I/O) Analog or digital Closed-loop speed control, master-slave operation, only for Hoist_1 and Hoist_2 CU310-2 Master is speed controlled Slave is torque controlled Note The script is a supporting tool for the application. When required, this script can be expanded, so that no guarantee can be accepted for a complete match. Note The commissioning can also be performed with a BOP20, see Section BOP20 Basic Operator Panel (Page 14). Operating Instructions, 07/

90 Standard applications and adaptation options 7.1 Standard application, SingleAxis 7.1 Standard application, SingleAxis In the standard application "SingleAxis", a drive object (DriveObject) with the name "DriveAxis" is created at a SINAMICS CU The know-how-protected Crane DCC library is located below this drive object. In addition, an executable script is provided in the "Scripts" folder. When this script is started, a dialog window based on the Internet Explorer is opened. You can either select the "Hoist" and "Gantry/Trolley" function module in this dialog window. Depending on your selection, the DCC blocks required are connected. Then select whether the drive is to be controlled via PROFIBUS DP or terminals (I/O). When selecting the communication via ONBOARD I/O you can choose between an analog and a digital master switch setpoint. With the selection, the interface is preconfigured via the script file; see Communication (Page 47). In addition, you can specify the path and name of the log file. This allows the scripting run to be checked to ensure that it is correct. Figure 7-1 Dialog box to select the function module and communication interface 90 Operating Instructions, 07/2012

91 Standard applications and adaptation options 7.1 Standard application, SingleAxis Note The script must be contained in the script folder under the associated hoist, gantry or trolley drive object. Otherwise, it will not be executed correctly or fully; for more information concerning script execution, see Section Configuring the PROFIBUS connection (Page 49). Note The SingleAxis standard application is created for a drive object with encoder. If the "Gantry/trolley" drive does not have an encoder, the STARTER tool must be used to delete the encoder in the project drive configuration Setpoint channel DigitalMasterSwitch DCC block When executing the script file, two types of setpoint input are offered for communication via terminal assignment. You can choose between analog input or digital input for specifying a setpoint. You can parameterize several speed setpoints for the digital input. The parameterized fixed speed setpoints act when digital inputs are selected. Symbol Note One of the input parameters p23000 or p23001 must be set otherwise "0 (zero)" is issued at the block output. Operating Instructions, 07/

92 Standard applications and adaptation options 7.1 Standard application, SingleAxis Brief description The open DigitalMasterSwitch DCC block configured for the Control Unit causes four different, fixed setpoints to act when the inputs are selected. Note The configuration of the run sequence is described in Section General information (Page 21). Figure 7-2 Overview of digital master switches Mode of operation Different velocity specifications are configured as percentage in the parameters p23021 to p These velocity specifications can then be controlled by selecting the parameters p23000 to p The parameters p23000 and p23001 specify the direction of rotation. If parameter p23000 is active, the axis turns in the positive direction. The axis then turns in the negative direction when parameter p23001 becomes active. The drive stops when both inputs are active. Connections SINAMICS parameter number Name Connectio n type Default assignment Data type Meaning p23000 bospeedlimit1_posdirection IN 0 BOOL Select speed specification 1; positive direction of rotation specification. p23001 bospeedlimit1_negdirection IN 0 BOOL Select speed specification 1; negative direction of rotation specification. p23002 bospeedlimit2 IN 0 BOOL Select speed specification 2 p23003 bospeedlimit3 IN 0 BOOL Select speed specification 3 p23004 bospeedlimit4 IN 0 BOOL Select speed specification 4 p23021 rspeedlimit1 IN 10 REAL Speed specification 1 as percentage p23022 rspeedlimit2 IN 30 REAL Speed specification 2 as percentage p23023 rspeedlimit3 IN 60 REAL Speed specification 3 as percentage p23024 rspeedlimit4 IN 100 REAL Speed specification 4 as percentage r23050 routspeedsetpointdigitalms OUT 0 REAL Effective speed setpoint 92 Operating Instructions, 07/2012

93 Standard applications and adaptation options 7.1 Standard application, SingleAxis Note The DigitalMasterSwitch DCC block should be added to the same run sequence as all DCC blocks (see Section DCC blocks (Page 21)). This block should be calculated before the MasterSwitch DCC block. Set speed setpoints The various speed setpoints should be set as follows: Speed specification 4 (p23024) > speed specification 3 (p23023) Speed specification 3 (p23023) > speed specification 2 (p23022) Speed specification 2 (p23022) > speed specification 1 (p23021) The speed setpoints act as follows: Table 7-2 Speed setpoints setting bospeedlimit1_ posdirection p23000 bospeedlimit1_ negdirection p23001 bospeedlimit2 p23002 bospeedlimit3 p23003 bospeedlimit FALSE FALSE FALSE FALSE FALSE 0 TRUE TRUE no influence no influence no influence 0 Effective setpoint Table 7-3 Speed setpoints setting for the positive direction bospeedlimit1_ posdirection p23000 bospeedlimit1_ negdirection p23001 bospeedlimit2 p23002 bospeedlimit3 p23003 bospeedlimit Effective setpoint TRUE FALSE FALSE FALSE FALSE Positive; speed specification 1 TRUE FALSE TRUE FALSE FALSE Positive; speed specification 2 TRUE FALSE TRUE TRUE FALSE Positive; speed specification 3 TRUE FALSE TRUE TRUE TRUE Positive; speed specification 4 Operating Instructions, 07/

94 Standard applications and adaptation options 7.1 Standard application, SingleAxis Table 7-4 Speed setpoints setting for the negative direction bospeedlimit1_ posdirection p23000 bospeedlimit1_ negdirection p23001 bospeedlimit2 p23002 bospeedlimit3 p23003 bospeedlimit Effective setpoint FALSE TRUE FALSE FALSE FALSE Negative; speed specification 1 FALSE TRUE TRUE FALSE FALSE Negative; speed specification 2 FALSE TRUE TRUE TRUE FALSE Negative; speed specification 3 FALSE TRUE TRUE TRUE TRUE Negative; speed specification 4 MasterSwitch DCC block Note Information about the analog master switch can be found in Section DCC block MasterSwitch (Page 24). The main drive is operated in the control mode "closed-loop speed control". Figure 7-3 Standard application, SingleAxis CAUTION For hoisting applications, "Speed control without motor encoder" control mode is not permitted for safety reasons. 94 Operating Instructions, 07/2012

95 Standard applications and adaptation options 7.1 Standard application, SingleAxis StartPulse in combination with brake control The StartPulse DCC block should be used in combination with the SINAMICS braking control. After the command to open the brake, the appropriate torque must be applied for the load to prevent load sag. This is achieved using the start pulse. To do this, the torque at the output of the speed controller at standstill is retentively saved with p22071 "rtorquevalueretain" before the brake is closed. The speed controller is set to the retentively saved value using parameter r22077 "rsettorquevalue" when the signal to open the brake is output. This means that the torque is quickly established - therefore preventing load sag. The parameter p22072 "bocommandopenbrake" should be interconnected with parameter r / r The parameter p22073 "bocommandclosebrake" should be interconnected with parameter r Figure 7-4 CU310-2 hoist using the example of control via PROFIBUS Figure 7-5 CU310-2 (gantry/trolley) using the example of the control via PROFIBUS Operating Instructions, 07/

96 Standard applications and adaptation options 7.2 Master-slave operation for SingleAxis 7.2 Master-slave operation for SingleAxis The master-slave closed-loop torque control is used when two drives are connected to a common shaft. The master operates in the closed-loop speed controlled mode, the slave in the closed-loop torque controlled mode. The master sends the torque as torque setpoint to the slave. Master-slave operation is networked using a TM31 module and via the analog interface, i.e. the torque setpoint from the master is sent to the analog output of the TM31 module, which belongs to the master. For the slave, this value is read-in via the analog input of the TM31 module which belongs to the slave - and is used as torque setpoint. CAUTION For hoisting applications, "Speed control without motor encoder" control mode is not permitted for safety reasons. Figure 7-6 Overview, master-slave operation The main drives are operated in the control mode "closed-loop speed control". Further, it is possible to operate Hoist_1 (master) and Hoist_2 (slave) in the master-slave mode. 96 Operating Instructions, 07/2012

97 Standard applications and adaptation options 7.2 Master-slave operation for SingleAxis Figure 7-7 Master-slave operation Operating Instructions, 07/

98 Standard applications and adaptation options 7.3 Expanding a standard application and DCC chart 7.3 Expanding a standard application and DCC chart In all standard applications, the know-how protected Crane DCC blocks are saved under the drive objects. As a consequence, this DCC chart cannot be opened under the drive objects and application-specific DCC configurations cannot be made on the DCC chart. In general, a new DCC chart can be created under the SINAMICS CU control unit, see figure below. This chart can be configured in a user-specific way. For standard applications, a DCC chart (User-DCC) already exists under the control unit. The customer-specific requirements can be implemented in this DCC chart. Figure 7-8 Inserting a chart via PROFIBUS DP 98 Operating Instructions, 07/2012

99 Standard applications and adaptation options 7.4 Data units 7.4 Data units The input and output variables of a DCC block can be declared in the form of an adjustable parameter as well as in the form of a BiCo parameter. Only connections of a DCC block declared as BiCo parameters can be connected to the connector inputs (CI) and connector outputs (CO) of the drive. All block interfaces declared as BiCo parameters are per-unit variables. This means that calculations are performed with per-unit signal values within DCC. (1.0 corresponds to 100%). The conversion to the drive connectors - that have associated units - is performed automatically. If an interconnection is established to the Crane DCC blocks from another DCC chart, then this value may only move in the range -2.0 to This corresponds to a value range from % up to +200 %. If a connector output of DCC is interconnected with the basic device, this will always be interpreted as a referred value of the basic system. The absolute value in the basic device with the associated unit now depends on which unit and therefore which reference variable the selected connector input has in the basic system. When interconnecting the connector input for speed setpoint p1070 (function plan 3030), the per-unit (referred) output value from the DCC chart will automatically be multiplied with the reference variable "Reference speed" p2000 (in the example p2000 = 1500 rpm). In the SINAMICS basic system, a speed setpoint of 1800 rpm ( = p2000 * 1.2 = 1500 rpm * 1.2) will thus become effective. For BiCo interconnections to the basic system, it must therefore always be observed whether absolute variables or per-unit (referred) variables are being used in DCC. When interconnected with a connector input of the basic system with associated units, the connector output of the DCC chart will always (internally) be multiplied with its reference variable (with physical unit). Operating Instructions, 07/

100 Standard applications and adaptation options 7.5 Converting a BiCo parameter into an adjustable parameter 7.5 Converting a BiCo parameter into an adjustable parameter The input and output variables of a DCC block can be declared as input and output parameters in the form of an adjustable parameter as well as in the form of a BiCo parameter. You can identify the type of declaration using the comments of the block connection; see the diagram below. For more information, please refer to Ref. [3]. Figure 7-9 Structure of the block connection comment The following distinction must be made when declaring block outputs: Without asterisk: A pure display parameter that cannot be interconnected although it can be recorded using the trace function. With asterisk: A BiCo parameter for input and output of a DCC block can also be interconnected. The range from 0 to 4499 is available for the parameter numbers: The parameter type (adjustable or BiCo parameter) of the crane DCC blocks is permanently defined. Users can no longer change this. The setpoint input (p22000) of the master switch block is a BiCo parameter and this cannot be re-configured to become an adjustable parameter. However, there are two possibilities to enter fixed values at this input: 100 Operating Instructions, 07/2012

101 Standard applications and adaptation options 7.5 Converting a BiCo parameter into an adjustable parameter Possibility 1 In STARTER, in the setpoint channel of the drive object (tab, fixed setpoint wiring fixed setpoints), interconnect fixed value 1 as a percentage (p2900) to input p It is then possible to enter fixed setpoints via parameter p2900. Figure 7-10 Fixed setpoint interconnection Possibility 2 1. In STARTER, insert a DCC chart or expand an existing DCC chart under the CU, see Section Expanding a standard application and DCC chart (Page 98). Operating Instructions, 07/

102 Standard applications and adaptation options 7.5 Converting a BiCo parameter into an adjustable parameter 2. Create a DCC block (NOP1, type real) in this chart. Declare input parameter (@1000 Fixed Input Value) and output parameter (@*1001 Output Value), see figure below. Figure 7-11 DCC block 102 Operating Instructions, 07/2012

103 Standard applications and adaptation options 7.5 Converting a BiCo parameter into an adjustable parameter 3. Compile the DCC chart from STARTER. Figure 7-12 Compiling a DCC chart Operating Instructions, 07/

104 Standard applications and adaptation options 7.5 Converting a BiCo parameter into an adjustable parameter 4. The two new parameters can now be seen under the expert list of the CU. Figure 7-13 New parameters are visible 104 Operating Instructions, 07/2012

105 Standard applications and adaptation options 7.5 Converting a BiCo parameter into an adjustable parameter 5. The setpoint input of the master switch in the crane DCC block can be interconnected with the output parameter. Figure 7-14 Interconnecting the master switch setpoint Operating Instructions, 07/

106 Standard applications and adaptation options 7.5 Converting a BiCo parameter into an adjustable parameter 6. Finally, the new DCC block must be activated in the execution system, otherwise the block will not be computed. This can be executed as follows. Select the new DCC chart in the project navigator. In the shortcut menu (right mouse button), select "Set selection of runtime groups". Insert the new block into the execution system. Figure 7-15 Inserting the DCC block into the runtime group 7. Values can now be specified for the fixed setpoint. Observe the value range; see General information (Page 21). 106 Operating Instructions, 07/2012

Description and Tutorial for. SIMOCRANE Drive-Based Technology V1.0 SP1 HF2. with Sinamics CU 310-2

Description and Tutorial for. SIMOCRANE Drive-Based Technology V1.0 SP1 HF2. with Sinamics CU 310-2 Description and Tutorial for SIMOCRANE Drive-Based Technology V1.0 SP1 HF2 with CU 310-2 Product Management May 2015, Erlangen, Germany Overview Siemens Solution for Mid-Performance Crane Application A

More information

SIMOCRANE Drive-Based Sway Control

SIMOCRANE Drive-Based Sway Control Preface Fundamental safety instructions 1 SIMOCRANE Operating Instructions System description 2 Hardware interfaces 3 Function description 4 Installation/uninstallation 5 Commissioning 6 Parameters 7 Function

More information

SIMOCRANE Drive-Based Technology V1.0 SP2 Description and Tutorial

SIMOCRANE Drive-Based Technology V1.0 SP2 Description and Tutorial SIMOCRANE Drive-Based Technology V1.0 SP2 Description and Tutorial SIMOCRANE Product Portfolio S I M O C R A N E Crane Technology Crane Management System Advanced Technology High Performance (Remote) CMS

More information

Readme SiVArc V14 SP1 Update 6

Readme SiVArc V14 SP1 Update 6 Product version 1 Improvements in Update 6 2 Readme 05/2018 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as

More information

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3 Getting Started - Startdrive Introduction 1 Connecting the drive unit to the PC 2 Startdrive SINAMICS Getting Started Creating a project 3 Going online and incorporating devices 4 Commissioning the drive

More information

SIMATIC/SINAMICS. Getting started with SINAMICS V90 PN on S Motion Control. Fundamental safety instructions 1. Introduction

SIMATIC/SINAMICS. Getting started with SINAMICS V90 PN on S Motion Control. Fundamental safety instructions 1. Introduction Fundamental safety instructions 1 Introduction 2 SIMATIC/SINAMICS Getting started with SINAMICS V90 PN on S7-1500 Motion Control Getting Started Prepare the configuration 3 Create a project 4 Creating

More information

Siemens Spares. SIMOCRANE Drive-Based Sway Control. Preface. Fundamental safety instructions 1. System description 2. Hardware interfaces 3

Siemens Spares. SIMOCRANE Drive-Based Sway Control. Preface. Fundamental safety instructions 1. System description 2. Hardware interfaces 3 Preface Fundamental safety instructions 1 SIMOCRANE Operating Instructions System description 2 Hardware interfaces 3 Function description 4 Installation/uninstallation of 5 Commissioning 6 Parameters

More information

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of Inter Project Engineering Team engineering via Inter Project Engineering TIA Portal Basics of "Inter Project Engineering" 1 Creating an IPE file 2 Importing an IPE file 3 Team engineering via Inter Project Engineering Getting Started

More information

Power module PM-E DC24V/8A RO SIMATIC. ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface. Properties.

Power module PM-E DC24V/8A RO SIMATIC. ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface. Properties. Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) SIMATIC ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface Properties 1 Parameters 2 Diagnostics 3 Configuring 4 Manual

More information

SIMOTION. SIMOTION SCOUT Reading and Writing Drive Data. Preface. Fundamental safety instructions 1. Description 2.

SIMOTION. SIMOTION SCOUT Reading and Writing Drive Data. Preface. Fundamental safety instructions 1. Description 2. Preface Fundamental safety instructions 1 SIMOTION SIMOTION SCOUT Description 2 Function block 3 Example of an application 4 Function Manual Appendix A 04/2014 Legal information Warning notice system This

More information

Siemens Automation Products

Siemens Automation Products Introduction 1 Configuring the hardware in the offline mode 2 Startdrive Startdrive Getting Started SINAMICS S120 in Startdrive Getting Started Connecting the drive unit with the PC and going online 3

More information

Cycle and response times SIMATIC. S Cycle and response times. Preface. Documentation guide. Program processing 2. Cyclic program processing 3

Cycle and response times SIMATIC. S Cycle and response times. Preface. Documentation guide. Program processing 2. Cyclic program processing 3 Preface Documentation guide 1 SIMATIC S7-1500 Program processing 2 Cyclic program processing 3 Event-driven program processing 4 Function Manual 02/2014 A5E03461504-02 Legal information Warning notice

More information

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties.

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties. Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) SIMATIC ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface Properties 1 Parameters 2 Diagnostics 3 Configuring 4 Manual 06/2010

More information

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) SIMATIC ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Manual Preface Documentation guide 1 Product overview 2 Connecting 3 Parameter

More information

S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control

S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control Getting Started - Commissioning a CPU Introduction 1 31xC: Closed-loop control Preparation 2 SIMATIC S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control Learning units 3 Further Information

More information

MindSphere. Visual Explorer. Introduction. User roles for "Visual Explorer" Connecting "Visual Explorer" to MindSphere data. Creating Visualizations

MindSphere. Visual Explorer. Introduction. User roles for Visual Explorer Connecting Visual Explorer to MindSphere data. Creating Visualizations Introduction 1 User roles for "Visual Explorer" 2 MindSphere Connecting "" to MindSphere data 3 Creating Visualizations 4 Getting Started 06/2018 Legal information Warning notice system This manual contains

More information

Output Cams and Measuring Inputs SIMOTION. SIMOTION SCOUT Output Cams and Measuring Inputs. Preface. Output Cam TO - Part I. Cam Track TO - Part II

Output Cams and Measuring Inputs SIMOTION. SIMOTION SCOUT Output Cams and Measuring Inputs. Preface. Output Cam TO - Part I. Cam Track TO - Part II Preface 1 Output Cam TO - Part I 2 SIMOTION SIMOTION SCOUT Cam Track TO - Part II 3 Measuring Input TO - Part III 4 Function Manual 11/2010 Legal information Legal information Warning notice system This

More information

SIMOTION. Motion Control Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler 4.

SIMOTION. Motion Control Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler 4. Preface 1 Overview 2 SIMOTION Motion Control Configuring 3 Working with the SIMOTION Task Profiler 4 Function Manual Valid as from Version 4.4 04/2014 Legal information Warning notice system This manual

More information

Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual

Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual Class documentation COMOSKDictionary COMOS Trademarks 1 General 2 KDictionary 3 Platform Class documentation COMOSKDictionary Programming Manual 04/2012 A5E03777026-01 Legal information Legal information

More information

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1 Options for Accessing Documentation 1 Notes on the Product Documentation 2 SIMATIC Notes on the PCS 7 V8.0 SP2 system documentation 3 Process Control System PCS 7 PCS 7 system documentation - Readme V8.0

More information

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS SINAMICS G130 Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Voltage Sensing Module 10 (VSM10) Mechanical installation 3 Electrical installation 4 Technical

More information

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken. Preface Overview 1 SIMATIC Process Control System PCS 7 Advanced Process Functions Operator Manual Operating Manual Material management 2 Material lot management 3 Storage location management 4 Parameter

More information

Deckblatt. APL Operator Guide SIMATIC PCS 7. Application description June Applikationen & Tools. Answers for industry.

Deckblatt. APL Operator Guide SIMATIC PCS 7. Application description June Applikationen & Tools. Answers for industry. Deckblatt SIMATIC PCS 7 Application description June 2011 Applikationen & Tools Answers for industry. Industry Automation and Drive Technologies Service & Support Portal This article is taken from the

More information

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example Introduction 1 Application example 2 Industrial Controls Motor management and control devices SIMOCODE pro - Application examples Application Manual Example circuits control functions 3 Further application

More information

ST (6ES7132-6FD00-0BB1)

ST (6ES7132-6FD00-0BB1) SIMATIC ET 200SP Digital output module DQ 4x24..230VAC/2A ST (6ES7132-6FD00-0BB1) Manual Edition 02/2014 Answers for industry. DQ 4x24..230VAC/2A ST Preface Guide to documentation 1 SIMATIC ET 200SP DQ

More information

SITOP UPS1600 under STEP 7 V5. SITOP UPS1600 under STEP 7 V5. Introduction. Safety notes. Description 3. Assigning the IP address

SITOP UPS1600 under STEP 7 V5. SITOP UPS1600 under STEP 7 V5. Introduction. Safety notes. Description 3. Assigning the IP address Introduction 1 Safety notes 2 Description 3 Getting Started Assigning the IP address 4 Installing and configuring the SITOP UPS1600 in STEP 7 5 V5 Parameterizing the SITOP UPS1600 6 Legal information Warning

More information

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O Digital electronic module 4DI DC24V HF (6ES7131-4BD01-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 04/2007 A5E01077141-01

More information

SITOP UPS1600 under STEP 7 V13. SITOP UPS1600 under STEP 7 V13. Introduction. Safety notes. Description. Assigning the IP address

SITOP UPS1600 under STEP 7 V13. SITOP UPS1600 under STEP 7 V13. Introduction. Safety notes. Description. Assigning the IP address Introduction 1 Safety notes 2 Description 3 Assigning the IP address 4 SITOP UPS1600 under STEP 7 V13 Getting Started Installing and configuring the SITOP UPS1600 in STEP 7 5 V13 Parameterizing the SITOP

More information

Parameter 1. Faults and alarms 2 SIMOCRANE. Truck Positioning System (TPS) Parameter Manual. applies to SIMOCRANE TPS Version 1.1

Parameter 1. Faults and alarms 2 SIMOCRANE. Truck Positioning System (TPS) Parameter Manual. applies to SIMOCRANE TPS Version 1.1 1 Faults and alarms 2 SIMOCRANE Parameter Manual applies to SIMOCRANE TPS Version 1.1 03/2012 Legal information Warning notice system This manual contains notices you have to observe in order to ensure

More information

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface. Properties 1. Parameters 2. Diagnostics 3.

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface. Properties 1. Parameters 2. Diagnostics 3. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface Properties 1 Parameters 2 Diagnostics 3 Configuring 4 Manual 04/2007 A5E01119980-01

More information

SINAMICS POLYGON. Master-value-dependent characteristic functionality. Function Manual

SINAMICS POLYGON. Master-value-dependent characteristic functionality. Function Manual s SINAMICS POLYGON Master-value-dependent characteristic functionality Function Manual Edition 10/2015 s Preface Fundamental safety instructions 1 SINAMICS POLYGON Master-value-dependent characteristic

More information

SIMOTION. SIMOTION SCOUT Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler. Function Manual 05/2009

SIMOTION. SIMOTION SCOUT Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler. Function Manual 05/2009 SIMOTION SIMOTION SCOUT SIMOTION SIMOTION SCOUT Preface 1 Overview 2 Configuring 3 Working with the SIMOTION Task Profiler 4 Function Manual 05/2009 Legal information Legal information Warning notice system

More information

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1] Loading the block library 1 Deleting program block Main [OB1] 2 TIA Portal SIMATIC Getting Started Copying program blocks 3 Copying tag tables 4 Compiling a project 5 Load project into the CPU 6 03/2013

More information

COMOS. Platform Class documentation RevisionMaster_dll. Class: RevisionInfo 1. Class: RevisionMaster 2. Programming Manual

COMOS. Platform Class documentation RevisionMaster_dll. Class: RevisionInfo 1. Class: RevisionMaster 2. Programming Manual Class: RevisionInfo 1 Class: RevisionMaster 2 COMOS Platform Class documentation RevisionMaster_dll Programming Manual 03/2017 V10.2.1 A5E39859923-AA Legal information Warning notice system This manual

More information

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme Validity 1 Improvements in STEP 7 2 SIMATIC Improvements in WinCC 3 05/2017 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety,

More information

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4. Security information 1 Overview 2 SIMATIC Process Control System PCS 7 Notes on Installation 3 Notes on usage 4 Readme 04/2016 A5E36515375-AA Legal information Warning notice system This manual contains

More information

SIMOTION. Motion control Output Cams and Measuring Inputs. Preface 1. Fundamental safety instructions 2. Output Cam TO - Part I 3

SIMOTION. Motion control Output Cams and Measuring Inputs. Preface 1. Fundamental safety instructions 2. Output Cam TO - Part I 3 Preface 1 Fundamental safety instructions 2 SIMOTION Motion control Output Cam TO - Part I 3 Cam Track TO - Part II 4 Measuring Input TO - Part III 5 Function Manual Valid as of Version 4.4 04/2014 Legal

More information

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.6 11/2013 A5E32845290B AA

More information

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS SINAMICS G130 Operating instructions 03/2011 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Voltage Sensing Module 10 (VSM10) Mechanical installation 3 Electrical installation 4 Technical

More information

Counting, measurement and position. detection SIMATIC. S7-1500, ET 200MP, ET 200SP Counting, measurement and position detection.

Counting, measurement and position. detection SIMATIC. S7-1500, ET 200MP, ET 200SP Counting, measurement and position detection. Counting, measurement and position detection SIMATIC S7-1500, ET 200MP, ET 200SP Counting, measurement and position detection Function Manual Preface Documentation guide 1 The basics of counting, measurement

More information

Performance data abgn SCALANCE W770/W730 SIMATIC NET. Industrial Wireless LAN Performance data abgn SCALANCE W770/W730.

Performance data abgn SCALANCE W770/W730 SIMATIC NET. Industrial Wireless LAN Performance data abgn SCALANCE W770/W730. Performance data 802.11 abgn SCALANCE W770/W730 Technical data 1 SIMATIC NET Industrial Wireless LAN Performance data 802.11 abgn SCALANCE W770/W730 Reference Manual 07/2014 C79000-G8976-C370-01 Legal

More information

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information SIMATIC Automation Tool features 1 Known problems 2 SIMATIC S7/HMI SIMATIC Automation Tool V3.1 SP1 product information Product Information V3.1 SP1, 05/2018 A5E43714043-AA Legal information Warning notice

More information

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O Power module PM-E DC24..48V/AC24..230V (6ES7138-4CB11-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Configuring 4 04/2007

More information

Performance data abgn PCIe Minicard MPCIE-R1-ABGN-U3 SIMATIC NET

Performance data abgn PCIe Minicard MPCIE-R1-ABGN-U3 SIMATIC NET Performance data 802.11abgn PCIe Minicard MPCIE-R1-ABGN-U3 Technical specifications 1 SIMATIC NET Industrial Wireless LAN Performance data 802.11abgn PCIe Minicard MPCIE-R1-ABGN-U3 Reference Manual 07/2014

More information

RF-MANAGER simulator SIMATIC. RFID-Systems RF-MANAGER simulator. Simulating projects. Compact Operating Instructions 06/2010 A5E

RF-MANAGER simulator SIMATIC. RFID-Systems RF-MANAGER simulator. Simulating projects. Compact Operating Instructions 06/2010 A5E Simulating projects 1 SIMATIC RFID-Systems Compact Operating Instructions 06/2010 A5E01074276-03 Legal information Legal information Warning notice system This manual contains notices you have to observe

More information

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken. Trademarks 1 Introduction 2 COMOS Operations Working with the "" plugin 3 Working with the " Diagram" plugin 4 User interface reference 5 Operating Manual 04/2012 A5E03778386-01 Legal information Legal

More information

SINAMICS SINAMICS G120. Frequency inverter with Control Units CU240E-2 CU240E-2 DP CU240E-2 F CU240E-2 DP-F. Function Manual Safety Integrated 07/2010

SINAMICS SINAMICS G120. Frequency inverter with Control Units CU240E-2 CU240E-2 DP CU240E-2 F CU240E-2 DP-F. Function Manual Safety Integrated 07/2010 SINAMICS G120 Frequency inverter with Control Units CU240E-2 CU240E-2 DP CU240E-2 F CU240E-2 DP-F Function Manual Safety Integrated 07/2010 SINAMICS Answers for industry. Safety Integrated Function Manual,

More information

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s Safety information 1 General information 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5

More information

First Steps in Commissioning CPU. 31xC: Positioning with digital output SIMATIC

First Steps in Commissioning CPU. 31xC: Positioning with digital output SIMATIC First Steps in Commissioning CPU 31xC: Positioning with digital output Introduction 1 Preparation 2 SIMATIC S7-300 First Steps in Commissioning CPU 31xC: Positioning with digital output Learning units

More information

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL. Product Information Mixed Configuration ET 200SP / ET 200AL SIMATIC ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL Product Information Preface Application planning 1 Mounting 2 Connection

More information

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E s General Information 1 Connection 2 Automatic Transfer Controller User Interface 3 Menus 4 Remote Control Software Manual Edition 01/2010 A5E02469028-01 Legal information Warning notice system This manual

More information

Configuration limits for products of the SIMATIC NET PC Software V8.1 SIMATIC NET

Configuration limits for products of the SIMATIC NET PC Software V8.1 SIMATIC NET Configuration limits for products of the SIMATIC NET PC Software V8.1 SIMATIC NET Configuration limits for products of the SIMATIC NET PC Software V8.1 Application manual Communications partners and configuration

More information

SINAMICS G120 SINAMICS G120C

SINAMICS G120 SINAMICS G120C SINAMICS G120 SINAMICS G120C frequency inverter SINAMICS G120 frequency inverter with the Control Units CU240E-2 CU240E-2 F CU240E-2 DP CU240E-2 DP-F Safety Integrated Function Manual 01 2011 SINAMICS

More information

Industrial Controls. Motor management and control devices SIMOCODE pro. Introduction 1. Configuring a reversing starter. List of abbreviations

Industrial Controls. Motor management and control devices SIMOCODE pro. Introduction 1. Configuring a reversing starter. List of abbreviations Introduction 1 Configuring a reversing starter 2 Industrial Controls A List of abbreviations Motor management and control devices Getting Started 05/2018 A5E40507294002A/RS-AB/002 Legal information Warning

More information

BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC. ET 200SP BaseUnits. Preface. Guide to the documentation 1. Product overview 2

BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC. ET 200SP BaseUnits. Preface. Guide to the documentation 1. Product overview 2 BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC ET 200SP BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) Manual Preface Guide to the documentation 1 Product overview 2 BaseUnits for I/O modules 3 BaseUnits

More information

Spring Training Atlanta, GA

Spring Training Atlanta, GA Spring Training 2007 - Atlanta, GA Sinamics S120 Work Shop with CU310 DP Sinamics S120 Overview featuring CU310 DP AC / AC demo unit Lab 1 Lab 2 Lab 3 Lab 4 Lab 5 CU310 DP Servo & Vector Drive Commissioning

More information

Application example Single-axis application. SIMOCRANE Drive-Based Sway Control V1.0 SP2. Siemens Industry Online Support

Application example Single-axis application. SIMOCRANE Drive-Based Sway Control V1.0 SP2. Siemens Industry Online Support Application example Single-axis application SIMOCRANE Drive-Based Sway Control V1.0 SP2 https://support.industry.siemens.com/cs/ww/en/view/109483531 Siemens Industry Online Support Legal information Legal

More information

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions SIMATIC Ident RFID systems Compact Operating Instructions Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to

More information

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0) 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32- SIMATIC Preface 1 Properties 2 Diagnostics 3 ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32- Manual 10/2015

More information

Key Panels Library SIMATIC HMI. Key Panels Library. Preface 1. Installation of Key Panels Library. Working with the Key Panels Library

Key Panels Library SIMATIC HMI. Key Panels Library. Preface 1. Installation of Key Panels Library. Working with the Key Panels Library Preface 1 Installation of Key Panels Library 2 SIMATIC HMI Working with the Key Panels Library 3 Function description 4 Configuration Manual 11/2011 A5E03740571-01 Legal information Legal information Warning

More information

SIMATIC. Process Control System PCS 7 Advanced Process Functions Operator Manual. Preface. Security information 1. Overview 2. Material management 3

SIMATIC. Process Control System PCS 7 Advanced Process Functions Operator Manual. Preface. Security information 1. Overview 2. Material management 3 Preface Security information 1 SIMATIC Process Control System PCS 7 Advanced Process Functions Operator Manual Operating Manual Overview 2 Material management 3 Material lot management 4 Storage location

More information

Primary Setup Tool (PST) SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Description. Software installation 2

Primary Setup Tool (PST) SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Description. Software installation 2 Preface Description 1 SIMATIC NET Industrial Ethernet / PROFINET Software installation 2 Functions 3 Configuration Manual 07/2014 C79000-G8976-C204-06 Legal information Warning notice system This manual

More information

SIMOCRANE Drive-Based Sway Control V1.0 SP1 HF1 Siemens AG All Rights Reserved. siemens.com/cranes

SIMOCRANE Drive-Based Sway Control V1.0 SP1 HF1 Siemens AG All Rights Reserved. siemens.com/cranes Siemens Cranes, November 2016 SIMOCRANE Drive-Based Sway Control V1.0 SP1 HF1 siemens.com/cranes Siemens Cranes Our product portfolio S I M O C R A N E Crane Technology Crane Management System Advanced

More information

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2 Use with 0 to 70 C ambient temperature SIMATIC Preface 1 Product combination 2 Product family 3 Process Control System PCS 7 Use with 0 to 70 C ambient temperature System Manual 02/2015 A5E35458345-AA

More information

SIMOCRANE SC integrated OHBC, Gantry crane

SIMOCRANE SC integrated OHBC, Gantry crane Foreword Basic safety instructions (software) 1 SIMOCRANE Operating Instructions System description 2 Description of the AddOn sway control system 3 Adding the AddOn sway control system to the user 4 project

More information

SIMOCRANE Drive-Based Sway Control V1.0 SP2

SIMOCRANE Drive-Based Sway Control V1.0 SP2 SIMOCRANE Drive-Based Sway Control V1.0 SP2 siemens.com/cranes SIMOCRANE Product Portfolio High Performance Mid Performance Crane Management System (Remote) CMS CMS Lean SIMOCRANE Crane Technology Advanced

More information

PD PA AP How To Configure Maxum II TimeServer Access

PD PA AP How To Configure Maxum II TimeServer Access Designating the TimeServer on the Analyzer 1 Running a TimeServer as an Application 2 Allowing the TimeServer Application Through the Firewall 3 PD PA AP How To Configure Maxum II TimeServer Access Application

More information

PN/CAN LINK Configuring the "CANopen manager" and "CANopen slave" operating modes TIA Portal V14, SIMATIC S7 https://support.industry.siemens.com/cs/ww/en/view/109751077 Siemens Industry Online Support

More information

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2.

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2. Security information 1 Preface 2 SIMATIC Configuration 3 Process Control System PCS 7 Configuration McAfee Endpoint Security 10.5 Installation Manual 03/2018 A5E44395618-AA Legal information Warning notice

More information

Block Library Motor Starter SIRIUS for SIMATIC PCS 7

Block Library Motor Starter SIRIUS for SIMATIC PCS 7 Industrial Controls Block Library Motor Starter SIRIUS for SIMATIC PCS 7 SIRIUS Motor Starter PCS 7 Library V7.1+SP2 / SIRIUS Motor Starter PCS 7 Library V8 Migration 8.0+SP1 Getting Started Edition 08/2013

More information

Industrial Controls. SIMOCODE pro SIMOCODE pro PCS 7 Library. Preface. Security information. Product specific security. information.

Industrial Controls. SIMOCODE pro SIMOCODE pro PCS 7 Library. Preface. Security information. Product specific security. information. Industrial Controls SIMOCODE pro Preface 1 Product specific security Security information 2 information 3 Introduction 4 5 References 6 List of Abbreviations 7 10/2018 A5E36558134002A/RS-AB/002 Legal information

More information

Device manual SINAMICS SINAMICS G120. Distributed inverter box Control cabinet for wall or floor mounting.

Device manual SINAMICS SINAMICS G120. Distributed inverter box Control cabinet for wall or floor mounting. Device manual SINAMICS SINAMICS G120 Control cabinet for wall or floor mounting Edition 06/2018 www.siemens.com/drives Safety note 1 Description 2 SINAMICS SINAMICS G120 Manual Mounting 3 Connection 4

More information

SIMATIC. Process control system PCS 7 Operator Station (V9.0 SP1) Security information 1. Preface 2

SIMATIC. Process control system PCS 7 Operator Station (V9.0 SP1) Security information 1. Preface 2 SIMATIC Process control system PCS 7 Configuration Manual Valid for PCS 7 as of V9.0 SP1 Security information 1 Preface 2 The PCS 7 Operator Station 3 Introduction to OS configuration 4 Setting the languages

More information

Siemens Industrial s

Siemens Industrial s SINAMICS G130 Operating Instructions 05/2010 SINAMICS Siemens Industrial s Sinusoidal filter Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical

More information

Siemens Drives & PLCs

Siemens Drives & PLCs Automation System S7-300: Getting Started CPU 31xC: Commissioning Introduction 1 Preparation 2 SIMATIC S7-300 Automation System S7-300: Getting Started CPU 31xC: Commissioning Learning units 3 Further

More information

Digital output module. DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) SIMATIC

Digital output module. DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) SIMATIC Digital output module DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) SIMATIC S7-1500/ET 200MP Digital output module DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) Manual Preface Documentation guide 1 Product overview

More information

IO-Link Master (6ES7147-4JD00-0AB0) SIMATIC. ET 200pro IO-Link Master (6ES7147-4JD00-0AB0) Preface. Documentation guide. Product overview.

IO-Link Master (6ES7147-4JD00-0AB0) SIMATIC. ET 200pro IO-Link Master (6ES7147-4JD00-0AB0) Preface. Documentation guide. Product overview. IO-Link Master (6ES7147-4JD00-0AB0) SIMATIC ET 200pro IO-Link Master (6ES7147-4JD00-0AB0) Manual Preface Documentation guide 1 Product overview 2 Wiring 3 Parameters/address space 4 Diagnostics alarms

More information

party software COMOS Platform Third-party software Trademarks 1 Requirements for the system environment Third-party software releases Operating Manual

party software COMOS Platform Third-party software Trademarks 1 Requirements for the system environment Third-party software releases Operating Manual Third- party software Trademarks 1 Requirements for the system environment 2 COMOS releases 3 Platform Operating Manual 08/2011 A5E03638321-01 Legal information Legal information Warning notice system

More information

SIMATIC. Process Control System PCS 7 PCS 7 Documentation (V8.1) Options for Accessing Documentation 1. Documentation for the Planning Phase 2

SIMATIC. Process Control System PCS 7 PCS 7 Documentation (V8.1) Options for Accessing Documentation 1. Documentation for the Planning Phase 2 Options for Accessing Documentation 1 Documentation for the Planning Phase 2 SIMATIC Process Control System PCS 7 Documentation for the Realization Phase 3 Documentation on commissioning, operation, diagnostics

More information

Class: POptions 1 COMOS. Platform Class documentation POptions_dll. Programming Manual 04/2014 A5E AA

Class: POptions 1 COMOS. Platform Class documentation POptions_dll. Programming Manual 04/2014 A5E AA 1 COMOS Platform Programming Manual 04/2014 A5E32035508-AA Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to

More information

Examples for SIMATIC IPC Support. Package for VxWorks SIMATIC. Industrial PC Examples for SIMATIC IPC Support Package for VxWorks

Examples for SIMATIC IPC Support. Package for VxWorks SIMATIC. Industrial PC Examples for SIMATIC IPC Support Package for VxWorks Examples for SIMATIC IPC Support Package for VxWorks Importing examples in Wind River Workbench V4 1 Examples for the DMAPI interface 2 SIMATIC Example for function calls of the hardware-dependent functions

More information

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode Global FW Rulesets SIMATIC NET Industrial Ethernet Security Preface 1 Firewall in standard mode 2 Firewall in advanced mode 3 Configuring a VPN tunnel 4 Configuring remote access via a VPN tunnel 5 Getting

More information

SIMATIC. ET 200S distributed I/O. 4 IQ-SENSE module (6ES7138-4GA00-0AB0) Preface. 4 IQ-SENSE module (6ES7138-4GA00-0AB0) Parameters 2.

SIMATIC. ET 200S distributed I/O. 4 IQ-SENSE module (6ES7138-4GA00-0AB0) Preface. 4 IQ-SENSE module (6ES7138-4GA00-0AB0) Parameters 2. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O 4 IQ-SENSE module (6ES7138-4GA00-0AB0) Manual Preface 4 IQ-SENSE module (6ES7138-4GA00-0AB0) 1 Parameters 2 Diagnostics 3 Control interface

More information

PROFIenergy product information SIMATIC. ET 200SP PROFIenergy product information. PROFIenergy 1. Product Information 12/2015 A5E AH

PROFIenergy product information SIMATIC. ET 200SP PROFIenergy product information. PROFIenergy 1. Product Information 12/2015 A5E AH PROFIenergy 1 SIMATIC ET 200SP Product Information 12/2015 A5E03871936-AH Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety,

More information

Operator Station (V8.0) SIMATIC. Process Control System PCS 7 Operator Station (V8.0) Preface 1. The PCS 7 Operator Station

Operator Station (V8.0) SIMATIC. Process Control System PCS 7 Operator Station (V8.0) Preface 1. The PCS 7 Operator Station SIMATIC Process Control System PCS 7 Configuration Manual Preface 1 The PCS 7 Operator Station 2 Introduction to OS configuration 3 Setting languages 4 Configuring OS data in SIMATIC Manager 5 Configuring

More information

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2 dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Operating Instructions Safety information 1 General 2 Mechanical installation 3 Electrical

More information

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional Setting up security in STEP 7 Professional SIMATIC NET Industrial Ethernet Security Setting up security in STEP 7 Professional Preface 1 User interface and menu commands 2 Basic configuration 3 Firewall

More information

SIMATIC. Component Based Automation SIMATIC imap STEP 7 AddOn Creating PROFINET components. Preface. Creating PROFINET components in STEP 7

SIMATIC. Component Based Automation SIMATIC imap STEP 7 AddOn Creating PROFINET components. Preface. Creating PROFINET components in STEP 7 SIMATIC Component Based Automation SIMATIC Component Based Automation SIMATIC imap STEP 7 AddOn Creating PROFINET components Configuration Manual Preface Creating PROFINET components in STEP 7 1 SIMATIC

More information

SIMATIC. Automation Systems S7-300 CPU 317T-2 DP: Controlling a SINAMICS S120. Introduction. Preparation 2. Learning units 3. Further Information 4

SIMATIC. Automation Systems S7-300 CPU 317T-2 DP: Controlling a SINAMICS S120. Introduction. Preparation 2. Learning units 3. Further Information 4 SIMATIC Programmable Logic Controllers S7 300 SIMATIC Programmable Logic Controllers S7 300 CPU 317T-2 DP: Controlling a SINAMICS S120 SIMATIC Automation Systems S7-300 CPU 317T-2 DP: Controlling a SINAMICS

More information

Basic Functions for Modular. Machines SIMOTION. Motion Control Basic Functions for Modular Machines. Preface

Basic Functions for Modular. Machines SIMOTION. Motion Control Basic Functions for Modular Machines. Preface Basic Functions for Modular Machines SIMOTION Motion Control Basic Functions for Modular Machines Function Manual Preface Overview of the functionality of modular machines 1 Synchronizing SIMOTION devices

More information

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Preface 1. Additional documentation 2. Functions of the PCS 7 OS in process mode 3

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Preface 1. Additional documentation 2. Functions of the PCS 7 OS in process mode 3 Preface 1 Additional documentation 2 SIMATIC Process Control System PCS 7 Operating Instructions Functions of the PCS 7 OS in process mode 3 PCS 7 OS process mode - user interface 4 System operator inputs

More information

Siemens Spares COMOS. Operations Inspection. Introduction 1. Working with the "Inspection" plugin 2. Working with the "Inspection diagram" plugin 3

Siemens Spares COMOS. Operations Inspection. Introduction 1. Working with the Inspection plugin 2. Working with the Inspection diagram plugin 3 Introduction 1 Working with the "" plugin 2 COMOS Operations Working with the " diagram" plugin 3 Compatibility with P&ID and Isometrics 4 User interface reference 5 Operating Manual 04/2015 A5E32083790-AA

More information

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1 Preface Connecting SCALANCE S615 to the WAN 1 SIMATIC NET VPN tunnel between SCALANCE S615 and 2 SINEMA RC Server Industrial Ethernet Security Getting Started 07/2017 C79000-G8976-C390-02 Legal information

More information

Digital input module. DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) SIMATIC. ET 200AL Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) Preface

Digital input module. DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) SIMATIC. ET 200AL Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) Preface Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) SIMATIC ET 200AL Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) Manual Preface Documentation guide 1 Product overview 2 Wiring 3 Parameters/address

More information

Continuous Function Chart Getting. Started SIMATIC. Process Control System PCS 7 Continuous Function Chart Getting Started.

Continuous Function Chart Getting. Started SIMATIC. Process Control System PCS 7 Continuous Function Chart Getting Started. Continuous Function Chart Getting Started SIMATIC Process Control System PCS 7 Continuous Function Chart Getting Started Getting Started Preface 1 Creating a closed loop with a simulated process 2 Testing

More information

Class: DocumentManager 1 COMOS. Platform Class documentation DocumentManager_dll. Programming Manual 03/2017 V10.2.

Class: DocumentManager 1 COMOS. Platform Class documentation DocumentManager_dll. Programming Manual 03/2017 V10.2. Class: DocumentManager 1 COMOS Platform Class documentation DocumentManager_dll Programming Manual 03/2017 V10.2.1 A5E39863290-AA Legal information Warning notice system This manual contains notices you

More information

Applications & Tools. Control of the Safety Integrated Extended Functions of the SINAMICS S110 via the fail-safe inputs of the CU305 SINAMICS S110

Applications & Tools. Control of the Safety Integrated Extended Functions of the SINAMICS S110 via the fail-safe inputs of the CU305 SINAMICS S110 Cover sheet Control of the Extended Functions of the SINAMICS S110 via the fail-safe inputs of the CU305 SINAMICS S110 Application example November 2011 Applications & Tools Answers for industry. Industry

More information

MindSphere. MindConnect IoT Extension Getting Started. Introduction to MindSphere. Prerequisites 2. Preparations 3. MindConnect IoT Extension

MindSphere. MindConnect IoT Extension Getting Started. Introduction to MindSphere. Prerequisites 2. Preparations 3. MindConnect IoT Extension Introduction to MindSphere 1 Prerequisites 2 MindSphere MindConnect IoT Extension Getting Started Preparations 3 MindConnect IoT Extension 4 Verify data in Fleet Manager 5 Getting Started 07/2018 Legal

More information

SINAMICS. Safety. SINAMICS G120, G120C, G120D, G110M, SIMATIC ET 200pro FC-2 inverters. Function Manual

SINAMICS. Safety. SINAMICS G120, G120C, G120D, G110M, SIMATIC ET 200pro FC-2 inverters. Function Manual Safety Function Manual SINAMICS SINAMICS G120, G120C, G120D, G110M, SIMATIC ET 200pro FC-2 inverters Safety functions integrated in the drive - Safety Integrated Edition 01/2017 www.siemens.com/drives

More information

Software Kit. Automatic Door Controls. SIDOOR Software Kit. Introduction 1. General safety instructions. Installation. Uninstalling the software 4

Software Kit. Automatic Door Controls. SIDOOR Software Kit. Introduction 1. General safety instructions. Installation. Uninstalling the software 4 Introduction 1 General safety instructions 2 Automatic Door Controls SIDOOR Operating Instructions Installation 3 Uninstalling the software 4 Sidoor User Software 5 HCS12 Firmware Loader 6 Sidoor Manager

More information