CONDUCTOR W4. Installation instruction for W4.1 and W To mount the controller. Controller. Mounting on a DIN rail

Size: px
Start display at page:

Download "CONDUCTOR W4. Installation instruction for W4.1 and W To mount the controller. Controller. Mounting on a DIN rail"

Transcription

1 CONDUCTOR W Installation instruction for W. and W. 00 Controller To mount the controller. Mounting on a DIN rail Figure. Overview of the Controller. Pos. Product marking. Pos. Termination resistance. = The unit is the last node in the network = The unit is the first node in the network = The unit is situated between the first and last nodes Pos. Modular Contact / ModBUS RTU units (pressure sensor and room unit) Pos. Inputs: Wiring terminals for the connection of sensors. Pos. DIP switch for ModBUS RTU. (=on) boosts the controller to Modbus address (=on) access to Modbus register via BMS system (requires a restart of the controller) Pos. LED, indicates the status of the controller. Pos. Input and output for signal to external relay. Pos. Outputs: Wiring terminals for the connection of valve and damper actuators. Figure. To mount the controller. Pos. Plastic hooks Pos. Supporting surface Pos. DIN rail Pos. Snap-on fastener. To be installed above a false ceiling If a DIN rail is NOT available pre-mounted or is not available, the controller can be appropriately mounted above the false ceiling (not on the module). Product Identification Label Conductor RE W Modbus Adress Artnr: 00 RF id: 000 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIII Figure. Product identification label on the controller. Pos. Name of the product. Pos. ModBus RTU address default from factory. Pos. Part number. Pos. Controller ID number. Figure. To mount the controller. Pos. Supporting surface, NOT for the comfort module or climate beam. Pos. Screws. a. Secure the controller by means of screws in the upper lefthand and the lower right-hand corners. Use screws suitable for the supporting surface.

2 CONDUCTOR W.- W. (Hotel/Office) Monitoring system via ModBus Figure. CONDUCTOR W.: Integral Components 0 Controller Room unit Presence detector/ Key card Pressure sensor CO External temp. sensor Valve actuator Ventilation damper incl. damper actuator Conductor RE Conductor RU DETECT Occupancy/ SYST SENSO SYST PS DETECT Quality CONDUCTOR T-TG SYST TS- ACTUATOR b V NC CRTc -aaa- (aaa = dimension) Connect the presence sensor, check application parameter P_0 Connect the window contact, check application parameter P_0 Connect the pressure sensor to the Modular contact. Set the address on sensor: SA =, EA = Check application parameters P_, P_0 and P_. (P_0 allways 0 in appl W.) 0 Room unit RJ Modular contact Pressure sensor RJ Modular contact Data (B) MODBUS RS Data (A) Earth Data (B) MODBUS RS Data (A) Earth Resistance Temperature sensor 0 KTY + V AC -G0 0V 0 0V 0V Presence detector 0-0V +V AC -G0 Valve actuator, cooling -G0 +V Valve actuator, heating 0 -G0 +V -G0 Damper, supply air (SA) 0-0V +V -G0 Damper, extract air (EA) 0-0V +V 0-0V Signal CO +V AC -G0 Figure. Wiring diagram, CONDUCTOR W. Swegon reserves the right to alter specifications 00

3 CONDUCTOR W.- W. (Conference) Monitoring system via ModBus Figure. CONDUCTOR W.: Integral Components 0 Controller Room unit Presence detector Pressure sensor CO External temp. sensor Valve actuator Ventilation damper incl. damper actuator Conductor RE Conductor RU DETECT Occupancy SYST PS DETECT Quality CONDUCTOR T-TG SYST TS- ACTUATOR b V NC CRTc aaa- (aaa = dimension) Connect the presence sensor, check application parameter P_0 Connect the window contact, check application parameter P_0 Connect the pressure sensor to the Modular contact. Set the address on sensor: SA =, SA =, EA = Check application parameters P_, P_0 and P_. 0 Room unit RJ Modular contact Pressure sensor RJ Modular contact Data (B) MODBUS RS Data (A) Earth Data (B) MODBUS RS Data (A) Earth Resistance Temperature sensor 0 KTY Valve actuator, heating +V X -G0 + V AC -G0 0V 0 0V 0V Presence detector 0-0V +V AC -G0 Valve actuator, cooling -G0 +V 0 -G0 Damper, supply air (SA) 0-0V + V -G0 Damper, supply air (SA) 0-0V +V -G0 Damper, extract air (EA) 0-0V +V 0-0V Signal CO +V AC -G0 Figure. Wiring diagram, CONDUCTOR W. 00 Swegon reserves the right to alter specifications

4 CONDUCTOR W.- b a Figure. Wireless: xaaa, (pos a), Cable: RJ (pos b). Main menu Setup Figure 0. To mount the room unit (thermostat). Pos. Front piece. Pos. Back piece. Pos. Screws suitable for the supporting surface. Recommended installation height RU = standard height for light switches RU should not be exposed to direct sunlight, or other disturbing heat sources. Room air should be able to circulate around the front and sides of the RU. Enter code Service menu Regulator adjust Settings System info General Param. Appl. Param. Alarms k-factor SA Norm SA l/s Boost SA l/s Room unit no. Room temp. Serial Number Battery Level Enter code Enter code k-factor SA Boost SA l/s k-factor EA Offset l/s RF pair-up Language Application Sw. ver. RE Sw. ver. RU Parameter value P_0 ModBus address Min 0 Max Parameter values P_0 or room units Min 0 Max FirstTime func Temp C Temp H RF Quality Temp.calibration Energy saving Backlight Basescreen mode Set point step Commissioning Figure. Overview over the menu system of the room unit. Swegon reserves the right to alter specifications 00

5 CONDUCTOR W.- Room unit overview RF pair-up (When RJ not used) 0 Main menu Setup <Exit Select> OK sek. Figure. Overview of the main image of the room unit. Press code <Exit > Pos. Cursor key for moving DOWN. Pos. Cursor key for moving to the LEFT. Pos. Heating/cooling. Pos. Battery charge status/window status. Pos. Current airflow. Pos. Operating mode. Pos. Current temperature. Pos. Carbon dioxide content. Pos. Occupancy status Pos 0. Cursor key for moving UP. Pos. Cursor key for moving to the RIGHT. Pos. OK key. <Exit <Exit ModBUS RF pair-up RF Quality 0 RF pair-up Select>... Select> Conductor RE W Modbus Adress Artnr: 00 RF id: 000 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIII Product identification label on the controller. 00 Swegon reserves the right to alter specifications

6 CONDUCTOR W.- Conductor to BMS and SuperWise First and middle zone Last RE in zone Last zone Last RE in zone 0 WARNING: All electrical installation, including wiring the actuators, valve actuators and various sensors is to be carried out by the electrical contractor or the systems contractor. Safety precautions / Responsibility It is the responsibility of the user to do the following: Assess all the risks involved in the activities which are related to this instruction. Make sure that all necessary safety precautions are made be-fore starting the activities which are related to this instruction. For US and Canada market WARNING: The power feeding shall be a Low Voltage class circuit. Swegon reserves the right to alter specifications 00

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities MiG2 CONTROLLERS 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities The MiG2 controllers incorporate: 2 Inputs (Configurable as Resistive, 0 10V, 0 20mA or 4 20mA) 2 or 4 Relay Outputs

More information

Communicative controller for VAV systems

Communicative controller for VAV systems FCR015 Communicative controller for VAV systems Summary FCR015 is a communicative controller for heating and cooling panels and a VAV (variable air volume) damper. It measures temperature and CO 2 concentration

More information

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications 3 834 DESIO RX Individual room controllers for fan-coil systems, chilled ceilings and radiators, with MARK-compatible bus communications RXC20.1 RXC21.1 The RXC20.1 and RXC21.1 controllers are used for

More information

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function MXIO Compact I/O module Summary The MXIO multiple I/O compact module is a microprocessor-controlled, communicative module with the I/O mix optimized for larger HVAC control applications. The module uses

More information

HLS34 Modbus FCU/VAV Controllers installation instructions

HLS34 Modbus FCU/VAV Controllers installation instructions HLS34 Modbus FCU/VAV Controllers installation instructions The HLS34 is specifically designed for individual room temperature and zone control applications. The controllers have built-in RS-485 channel

More information

Pre-programmed room controller with display and communication

Pre-programmed room controller with display and communication revision 10 2017 RC-C3DOC Pre-programmed room controller with display and communication RC-C3DOC is a complete pre-programmed room controller from the Regio Midi series intended to control heating, cooling

More information

RC-CDTO. Pre-programmed room controller with display, communication and three-point control

RC-CDTO. Pre-programmed room controller with display, communication and three-point control revision 02 2016 RC-CDTO Pre-programmed room controller with display, communication and three-point control RC-CDTO is a complete pre-programmed room controller from the Regio Midi series intended to control

More information

Non-communicating room controllers

Non-communicating room controllers 3 882 DESIGO RXA Non-communicating room controllers RXA29.1 For fan-coil systems The RXA29.1 room controller are used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil systems,

More information

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display UC102 Communicative heating controller Summary UC102 is a communicative room heating controller with two inputs and one PWM output for control of a radiator or electrical heater. It can work autonomously,

More information

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station s 3 836 3836P01 Desigo TRA PL-Link IO Block Use with PXC3 series room automation station RXM39.1 The PL-Link IO Block contains the inputs and outputs controlled by a room automation station via PL-Link.

More information

Control systems. Efficient room control

Control systems. Efficient room control Control systems Efficient room control AIRCONTROL Efficient room control with X-AIRCONTROL Humidity Occupancy Increasingly demanding requirements on energy efficiency as well as the latest EU regulations

More information

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor 3 036 Room emperature Controller with 7-Day ime Switch, LCD and opt Remote emperature Sensor for heating systems RDE201 2-position control with ON/OFF output for heating Operating modes: normal operation

More information

Modbus RTU/TCP GOLD RX/PX/CX/SD, GENERATION C/D Applicable to program version 1.05 and newer versions

Modbus RTU/TCP GOLD RX/PX/CX/SD, GENERATION C/D Applicable to program version 1.05 and newer versions Modbus RTU/TCP GOLD RX/PX/CX/SD, GENERATION C/D Applicable to program version 1.05 and newer versions Overview ModBus can access single addresses or multiple addresses simultaneously; either reading or

More information

RCF-230CTD. Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater

RCF-230CTD. Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater revision 03 2012 RCF-230CTD Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater RCF-230CTD is a room controller intended

More information

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN 1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,

More information

Smart Equipment Controls (SEC)

Smart Equipment Controls (SEC) Smart Equipment Controls (SEC) Product Bulletin SE-SPU1001-0, SE-SPU1002-0, SE-SPU1011-0, SE-SPU1011-0, SE-SPU1012-0, SE-SPU1004-0, SE-FDD1001-0, SE-ECO1001-0, SE-COM1001-0 Code No. LIT-12011934 Issued

More information

RCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs

RCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs revision 11 2013 RCF-230CD Communicating room thermostat for fan-coil applications with on/off outputs RCF-230CD intended to control heating and/or cooling in 2- or 4-pipe installations. Setpoint and fan

More information

CONTENTS CONTROLLERS room controllers room units control units PRODUAL 3 CATALOGUE

CONTENTS CONTROLLERS room controllers room units control units PRODUAL 3 CATALOGUE Catalogue 207 CONTENTS CONTROLLERS... 4 room controllers... 5 room units... 29 control units... 24 PRODUAL 3 CATALOGUE T U R KU I C T C ON T R OL L E R S Multifunctional controllers for optimal performance

More information

Control system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication

Control system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication X X testregistrierung Control system Type Central BMS interface DCP-FSL II-Stand-alone Pressure independent control valve Straight-way valve Modular, stand-alone room control system, specially for decentralised

More information

Options Overview. February 6, Ben Newell

Options Overview. February 6, Ben Newell Options Overview February 6, 2018 Ben Newell CERV2 Configuration Unitary All-in-One System Heat pump and dampers Fans same ECM fans as current CERV Fresh air and return filters (nom. 10 x20 ) Integrated

More information

7-day room temperature controller

7-day room temperature controller s 2 205 7-day room temperature controller Heating or cooling applications REV24.. Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display

More information

Weekday / weekend room temperature controller

Weekday / weekend room temperature controller s 2 203 Weekday / weekend room temperature controller Heating applications REV17.. Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display

More information

USER MANUAL. Longo programmable controller LPC-2.AQ1 Air Quality module. Version 1

USER MANUAL. Longo programmable controller LPC-2.AQ1 Air Quality module. Version 1 USER MANUAL Longo programmable controller LPC-2.AQ1 Air Quality module Version 1 SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +386(0)5 388 44 00 / e-mail: info@smarteh.si / www.smarteh.si

More information

SE7600E Series Application Guide

SE7600E Series Application Guide SE7600E Series Application Guide Schneider Electric SE7600E Series RTU Controller with IAQ Control Application Guide CONTENTS Solution Overview 2 Product Overview 3 Features & Benefits 3 System Overview

More information

STRA-17 Room controller. Installation and maintenance manual. Content

STRA-17 Room controller. Installation and maintenance manual. Content Content Installation preparations... Wiring diagram...3 Display handling...5 Technical data...6 Configuration...7 Operating modes...7 Controller modes...7 Activation operating modes...7 Control states...8

More information

FCU-MULTI Modbus Fan Coil Unit Controller

FCU-MULTI Modbus Fan Coil Unit Controller Product Sheet CT2.61 Controller Type FCU-MULTI FCU-MULTI Modbus Fan Coil Unit Controller FCU-MULTI is completely stand-alone operating room controller designed for room heating, cooling, ventilation, lighting

More information

DESCRIPTION OF MODBUS CONNECTION

DESCRIPTION OF MODBUS CONNECTION DESCRIPTION OF MODBUS CONNECTION MODBUS CONNECTION There is a possibility to control Air Handling Unit (AHU) from external management system (BMS), which work with MODBUS data processing. For MODBUS connection

More information

7-day room temperature controller

7-day room temperature controller s 2 208 7-day room temperature controller Heating applications REV34.. Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display and large

More information

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems. MXPLC Compact PLC process station Summary The MXPLC is a programmable process station with integrated I/O module with the I/O mix optimized for larger HVAC control applications. The multi-interface process

More information

Temperature controller Ducted systems

Temperature controller Ducted systems 2 725 Temperature controller Ducted systems Standard model without zoning functions RRV851 Multifunctional controller used for central control of ducted HVAC systems in combination with a QAX850 master

More information

EXOcompact. Third generation freely programmable controllers

EXOcompact. Third generation freely programmable controllers revision 1 013 EXOcompact Third generation freely programmable controllers Small, compact controller with different types of communication, with or without built-in display. EXOcompact can be used either

More information

Room Temperature Controller

Room Temperature Controller 3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:

More information

Pre-programmed room controller with display and communication

Pre-programmed room controller with display and communication revision 01 2014 RC-C3DOC Pre-programmed room controller with display and communication RC-C3DOC is a complete pre-programmed room controller from the Regio Midi series intended to control heating, cooling

More information

AIAS. Technical description

AIAS. Technical description Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains AIAS - and Efficient Heating Demand Products Controlled Tunnel Ventilation Fans 1 / 4 AIAS Technical description 2 / 9 AIAS -

More information

Semi flush-mounted room temperature controllers with LCD

Semi flush-mounted room temperature controllers with LCD s 3 077 RDD310 RDE410 Semi flush-mounted room temperature controllers with LCD For heating systems RDD310 RDE410 RDD310 and RDE410 features: Operating voltage AC 230 V 2-position control with On / Off

More information

IMIO100 IMIO105. DDC controllers. Summary

IMIO100 IMIO105. DDC controllers. Summary IMIO100 IMIO105 DDC controllers Summary DDC (Direct digital control) controller IMIO100 and IMIO105 are free programmable process stations with ARM Cortex M4 processor and OS FreeRTOS. They contain one

More information

SuperWISE II / SuperWISE II SC

SuperWISE II / SuperWISE II SC USER MANUAL SuperWISE II / SuperWISE II SC From software version 1.30 Content Explanation to abbreviations:... 2 General... 3 Log in... 3 Identification... 4 Explanation to abbreviations: The abbreviation

More information

SuperWISE Web Page Manual

SuperWISE Web Page Manual SuperWISE Web Page Manual SuperWISE, program version 1.14 1. General SuperWISE has a built-in web server that enables you to monitor, enter and change the settings on the various controllers in the WISE/Conductor

More information

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options. TUC03 Configurable Terminal Unit Controller Product Bulletin The TUC03 Configurable Terminal Unit Controller is designed specifically to provide direct digital control of terminal unit applications with

More information

Field selectable application type and room module series, via dip-switches on controller

Field selectable application type and room module series, via dip-switches on controller TUC03 Plus Configurable Terminal Unit Controller Product bulletin The TUC03 Plus configurable Terminal Unit Controller is specifically designed to provide an improved BACnet integration. It allows the

More information

RCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs

RCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs revision 04 2016 RCF-230CAD Room controller with communication for fancoil applications with two analogue 0...10 V DC outputs Intended to control heating and/or cooling in 2- or 4-pipe installations. Setpoint

More information

RVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting

RVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting G2522en Heating controller Installation Instructions RVL470 1 Installation 1.1 Place of installation In a dry room, e.g. the boiler room Mounting choices: In a control panel (on the inner wall or on a

More information

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02 s 3 878 RXL Room controller RXL24.1 Communicating controller for chilled ceiling and radiator applications CC-02 The RXL24.1 room controller is used for temperature control in individual rooms. For chilled

More information

Room unit with PPS2 interface

Room unit with PPS2 interface 1 626 Room unit with PPS2 interface for use with: controllers with a PPS2 interface QAA88.3 Room temperature measurement Key buttons for adjustment of the room temperature setpoint Key buttons for operating

More information

FCU-4 FAN COIL CONTROLLER

FCU-4 FAN COIL CONTROLLER FCU-4 FAN COIL CONTROLLER BACnet Enabled Description The FCU-4 is designed to provide complete control of fan coil units. The FCU-4 incorporates all the inputs and outputs to ensure that this advanced

More information

Control system for rotary heat exchanger EQRB, L=3,4

Control system for rotary heat exchanger EQRB, L=3,4 Installation instructions, drive system EQRB, L=3.4 sizes 005-072 General description A speed controlled drive system specifically adapted to drive rotary heat exchangers. No tuning is necessary. All control

More information

Non-communicating room controllers

Non-communicating room controllers 3 881 DESIO RXA on-communicating room controllers For fan-coil systems RXA20.1 RXA21.1 RXA22.1 The RXA20.1, RXA21.1 and RXA22.1 room controllers are used for temperature control in individual rooms. For

More information

Small distributed I/O module

Small distributed I/O module MLIO Summary Application Function Small distributed I/O module Small I/O module MLIO is a microprocessor-controlled, communiccative module for installation outside the control panel. It is used for topologies

More information

Supplementary operating instructions for your air curtain system Controller TMC 500

Supplementary operating instructions for your air curtain system Controller TMC 500 Supplementary operating instructions for your air curtain system Controller TMC 500 (Translation of the original) Serial number: Year: Please quote this number when contacting customer service! Date 08.04.2016

More information

Installation, Start-up and Operating Instructions

Installation, Start-up and Operating Instructions Installation, Start-up and Operating Instructions EVOLUTION SMART SENSOR FOR ZONING Cancels: NEW II ZONESMS-0-1 7-04 NOTE: Read the entire instruction manual before starting the installation. This symbol

More information

IQ-MP Gateway. Version apr Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel :

IQ-MP Gateway. Version apr Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel : IQ-MP Gateway Version 4.009 28. apr. 2011 Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel : +45 8880 7580 www.electrocom.dk p. 2 Description The IQ-MP Gateway is a communications module, which

More information

Product and Application Description

Product and Application Description Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design

More information

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A) Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow

More information

USER S MANUAL. DAS-G01 The Power of Tomorrow

USER S MANUAL. DAS-G01 The Power of Tomorrow USER S MANUAL DAS-G01 The Power of Tomorrow Richmond Heights 2018 0 USER S MANUAL DAS-G01 The Power of Tomorrow Richmond Heights 2018 Page 1 USER'S MANUAL TABLE OF CONTENTS Page # 1.0 GENERAL INFORMATION...

More information

Temperature controller Multi-zone ducted systems

Temperature controller Multi-zone ducted systems 2 727 emperature controller ulti-zone ducted systems ulti-zone model with up to six zone outputs RRV856 ultifunctional controller used for central control of ducted HVAC systems in combination with QAX850

More information

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000 1 542 1542P03 1542P01 1542P02 QXA2001 QXA2000 AQX2000 Condensation Monitor QXA2000 QXA2001 The QXA2000 condensation monitor is used to avoid damage due to condensation on chilled ceilings and in HVAC plant.

More information

Semi flush-mounted room temperature controllers with LCD

Semi flush-mounted room temperature controllers with LCD s 3 077 RDD310 RDE410 Semi flush-mounted room temperature controllers with LCD For heating systems RDD310 RDE410 RDD310 and RDE410 features: Operating voltage AC 230 V 2-position control with On / Off

More information

RCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs

RCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs revision 01 2015 RCF-230CAD Communicating room controller for fan-coil applications with two analogue 0...10 V DC outputs RCF-230CAD intended to control heating and/or cooling in 2- or 4-pipe installations.

More information

CDD4 Series Room CO2 Transmitter Installation Instructions

CDD4 Series Room CO2 Transmitter Installation Instructions CDD4 Series Room CO2 Transmitter Installation Instructions Introduction The CO2 transmitter uses Infrared Technology to monitor CO2 levels and outputs a linear 4-20 ma or 0-5/0-10 Vdc signal. Options include

More information

METASYS N2 open GOLD RX/PX/CX/SD, GENERATION C/D Applicable to program version 1.05 and newer versions

METASYS N2 open GOLD RX/PX/CX/SD, GENERATION C/D Applicable to program version 1.05 and newer versions METASYS N2 open GOLD RX/PX/CX/SD, GENERATION C/D Applicable to program version 1.05 and newer versions Metasys N2 open Metasys nodes contains up to 256 Virtual Objects. These virtual objects can be either

More information

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL 2 INTRODUCTION First and foremost we would like to thank you for purchasing this product. Our commitment to satisfying our customers can be seen

More information

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication 3 870 DESIO RXB Room controller for chilled ceilings and radiators with EIB bus communication RXB10.1 The RXB10.1 controller is used for temperature control in individual rooms: For chilled ceilings and

More information

MOD-RI Room Interface Modules with Modbus

MOD-RI Room Interface Modules with Modbus Product sheet MOD3.00 Type MOD-RI MOD-RI Room Interface Modules with Modbus The MOD-RI are room interface modules designed to provide room control interface for the building management systems. The MOD-RI

More information

TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company

TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display HTC 5 Features Australian Made and designed Power can be either 24V or 240V AC 10 Amp (Resistive) Potential free relay contacts

More information

Smart heating system. with wireless thermostats & smartphone control for every room. Get the most out of any water based underfloor heating

Smart heating system. with wireless thermostats & smartphone control for every room. Get the most out of any water based underfloor heating Smart heating system with wireless thermostats & smartphone control for every room Get the most out of any water based underfloor heating DETAILED OVERVIEW Control the heating in your home from anywhere.

More information

Room Temperature Controller

Room Temperature Controller 3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:

More information

Heating Circuit Controller

Heating Circuit Controller 2 706 Synco living Heating Circuit Controller RRV918 RF-controlled heating circuit controller for up to 8 heating circuits RF communication based on KNX standard (868 MHz, bidirectional) Connection facility

More information

Universal Controller

Universal Controller 3 342 Universal Controller For comfort control in HVAC & R-Systems Standalone electronic universal controller with P or PI response Operating voltage in accordance to type AC 24 V Control application selectable

More information

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM RTD-RA Installation Instructions 37.50 LEDS 4 3 2 1 D English Installation Instructions 80.00 80.00 ALL DIMENSIS IN MM C realtime Control Systems A B LEDS 4 3 2 1 D S21 J3 J6 1 2 3 4 J5 5 6 7 0V S1 0V

More information

EYE 200: DDC single-room controller, ecos200

EYE 200: DDC single-room controller, ecos200 Product data sheet 94.200 EYE 200: DDC single-room controller, ecos200 How energy efficiency is improved Individual unitary control, fan coil units, chilled-beam control system, etc. Features Part of the

More information

ABB i-bus KNX HCC/S Heating/cooling circuit controller

ABB i-bus KNX HCC/S Heating/cooling circuit controller ABB i-bus KNX HCC/S 2.2.1.1 Heating/cooling circuit controller Description of product The device is a modular DIN rail component (MDRC) in pro M design. It is intended for installation in distribution

More information

Dip Switch settings.

Dip Switch settings. Smart Temp Australia P/L EC 02 Multifunction Module Instruction Manual Ver 1.0 Preface The EC 02 module is a dedicated companion module for exclusive use with the Smart Temp SMT 770 thermostat (firmware

More information

rcc.1081 Installation Instructions

rcc.1081 Installation Instructions rcc.1081 Installation Instructions Table of Contents Introduction...1 Specifications...2 Mounting...3 Wiring...5 Wiring Method...7 BACnet Network Wiring...8 Setting BACnet Address...9 Setting the BACnet

More information

Installation manual CF8-W-Disp-AL

Installation manual CF8-W-Disp-AL Installation manual CF8-W-Disp-AL CO 2 transmitter with two relays mounted in industrial housing prepared for Modbus communication protocol 4 7 8 8 6 3 2 5 Wall plate 5 Snap-in lid 2 PCB (Factory supplied

More information

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers OEM CLIMATIX TM Room unit QAA822 with2- wire interface For use with Climatix controllers Remote control of air conditioning unit Mandík Measurement of the room temperature Buttons for starting, setting

More information

2001VT Temp & CO 2. - air quality sensor/controller NOTE!!! Manual for Installation. General. SenseAir AB

2001VT Temp & CO 2. - air quality sensor/controller NOTE!!! Manual for Installation. General. SenseAir AB 2001VT Temp & CO 2 - air quality sensor/controller Manual for Installation SenseAir AB EM_2001VT _rev4/dec. -00 General The IAQ-sensor 2001 VentoThermostat is a carbon dioxide and temperature monitor and

More information

User Manual BURCHARTH/BSK OK-1

User Manual BURCHARTH/BSK OK-1 H User Manual BURCHARTH/BSK OK-1-2.8 Graphic Screen - 2 Part Control Panel (Mainboard + Room Panel) - Aspirator, Vantilator 3 Level Speed Control - Automatic/Manuel Mode - 3 Stage Heater Control - English/Turkish

More information

Temperature Controller (Heat Pumps)

Temperature Controller (Heat Pumps) 3 347 Temperature Controller (Heat Pumps) For comfort control in HVAC & R systems Standalone electronic controller Programmable controller with preconfigured applications Three universal inputs for Ni1000,

More information

OP10. Pre-programmed, configurable controller for simple applications

OP10. Pre-programmed, configurable controller for simple applications revision 10 2013 OP10 Pre-programmed, configurable controller for simple applications The Optigo OP10 range of controllers can be set to handle everything from temperature or humidity control to control

More information

Super WISE Web Page Manual

Super WISE Web Page Manual Super WISE Web Page Manual Super WISE, program version 1.25 We reserve the right to make design modifications without prior notice. www.swegon.com 1 Contents Super WISE, program version 1.25... 1 Super

More information

Millennium Simplicity Elite Parameter Points and Quirks

Millennium Simplicity Elite Parameter Points and Quirks Millennium Simplicity Elite Parameter Points and Quirks How to access, view and change parameter settings Program Button Test Reset UP Alarms Change Data Address Down 1. Push the Program button once. The

More information

Indoor Unit Controller (IUC) Quick Reference and Fault Diagnosis

Indoor Unit Controller (IUC) Quick Reference and Fault Diagnosis Indoor Unit Controller (IUC) Quick Reference and Fault Diagnosis Date: 1 November 2015 Issue: 1 IUC software version: 1.5 Index 1. Introduction... 2 2. List of units with IUC... 2 3. Features and functions...

More information

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 574-294-2511 CANADA Dometic Corporation 46 Zatonski, Unit 3 Brantford, ON N3T 5L8 CANADA 519-720-9578 For Service Center

More information

Millenium II +: general characteristics

Millenium II +: general characteristics Millenium II +: general characteristics Starter kit Blind Temperature sensors Special starter kits Bare board Power supply Level detection Local extensions Accessories Standard Expandable Adjacent extensions

More information

Desigo RXA Room controllers without bus communications Range overview. CA2S3880en_ Building Technologies

Desigo RXA Room controllers without bus communications Range overview. CA2S3880en_ Building Technologies s Desigo RXA Room controllers without bus communications Range overview CA2S3880en_01 2012-08-30 Building Technologies Desigo TM RXA Room controllers without bus communications Contents Desigo RXA......

More information

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications s 3 856 Desigo RXC Room controller RXC39.5 Communicating room controller for fan-coil applications The RXC39.5 room controller is used for temperature control in individual rooms. For fan-coil systems

More information

Room controller STRA-17

Room controller STRA-17 Room controller STRA-17 Application example Room 2 Room 3 Room 4 SCADA EXOline alt. RS485 Modbus Transformer STRZ-24 (Required component) STRA-17 is a preprogrammed room controller intended to control

More information

USER'S GUIDE BARD-LINK TM LC /LC SOLID STATE DUAL UNIT LEAD/LAG CONTROLLER & TEC-EYE HAND-HELD DIAGNOSTIC TOOL

USER'S GUIDE BARD-LINK TM LC /LC SOLID STATE DUAL UNIT LEAD/LAG CONTROLLER & TEC-EYE HAND-HELD DIAGNOSTIC TOOL USER'S GUIDE BARD-LINK TM LC1000-100/LC1500-100 SOLID STATE DUAL UNIT LEAD/LAG CONTROLLER & TEC-EYE HAND-HELD DIAGNOSTIC TOOL Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead,

More information

TAC Xenta 121-FC Programmable Fan Coil Application

TAC Xenta 121-FC Programmable Fan Coil Application TAC Vista TAC Xenta 121-FC Programmable Fan Coil Application TAC Xenta 121-FC is an easily programmable controller intended for both 2-pipe and 4-pipe applications, with or without re-heat. It can be configured

More information

Temperature controller for multi-zone ducted systems

Temperature controller for multi-zone ducted systems 2 727 emperature controller for multi-zone ducted systems RRV856 ultifunctional controller used for central control of ducted HVAC systems in combination with QAX850 and QAW850 room units. ulti-zone model

More information

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions DIFFERENTIAL PRESSURE Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 OPERATIONAL

More information

24-hour room temperature controller

24-hour room temperature controller s 2 201 24-hour room temperature controller Heating applications REV13.. Use Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display and

More information

ISOMETER isoev425 with coupling device AGH420

ISOMETER isoev425 with coupling device AGH420 with coupling device AGH420 Insulation monitoring device for unearthed DC circuits (IT systems) for charging electric vehicles Preliminary datasheet isoev425_d00126_02_d_xxde/09.2015 with coupling device

More information

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13 s 3 875 RXB Room controller Communicating room controller for fan-coil applications FC-13 RXB39.1 The RXB39.1 room controller is used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil

More information

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS MAKING MODERN LIVING POSSIBLE Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new Controller.

More information

RTD-W Installation Instructions

RTD-W Installation Instructions RTD-W Installation Instructions 0V +V POWER 15-24VDC 0V S1 S2 S3 0V S4 S5 S6 English RTD-W Installation Instructions 100.00 RTD-W Control Interface realtime Control Systems 24VAC/30VDC, 1A REMC P1 P2 RS485

More information

USER GUIDE TEHR LU / TEHR-M

USER GUIDE TEHR LU / TEHR-M V1.1.1 (19.9.216) 1 (6) This user guide is for devices with the software version 1.1.1 or newer. MOUNTING WIRING The device can be installed in dry surroundings (IP2) by screws on the wall surface or on

More information

Heating Circuit Controller

Heating Circuit Controller 2 705 Synco 900 Heating Circuit Controller RRV912 RF-controlled heating circuit controller for up to 2 heating circuits RF communication based on KNX standard (868 MHz, bidirectional) Connection facility

More information

FEATURES AND BENEFITS. Installation and operation. Controller

FEATURES AND BENEFITS. Installation and operation. Controller DFC 350 & 450 DISPLACEMENT FREE COOLING Function The Dantherm Displacement Free Cooling (DFC) unit is a slim, passive cooling solution designed to remove excess heat from rooms with sensitive equipment.

More information

Compact universal controllers

Compact universal controllers 7 867 Compact universal controllers RWF55... The RWF55 is used mainly for controlling the temperature or pressure in oil- or gas-fired heating plants. If the relevant parameters are set, the RWF55 can

More information