About Suntex. Online Measurement and Control. Portable and Laboratory Instruments. ISO 9001: 2000 Certificated since 2001
|
|
- Claribel Osborne
- 5 years ago
- Views:
Transcription
1
2 About Suntex Suntex Instruments Company Ltd., established in 1982, has gained prestige and trust from our customers for dedication of providing professional, high-quality water analysis products and first-rate customer service. Online Measurement and Control Through 30 years experience and innovation, Suntex has launched its fifth generation of ph transmitter PC-3110, we called it intelligent transmitter, in The new intelligent transmitter series includes ph/orp, Conductivity/Resistivity, and Dissolved Oxygen models which are the most important parameters in the process controlling. The intelligent transmitter features for 1/4 DIN housing with IP65 protection, graphical menu, last calibration and overview of setting at a glance, and auto-sense backlight display, etc. There are also RS-485 Modbus models and PID controlling models to satisfy various demands. All of them are the proof of our continuous research and development to make the online measurement and controlling easier and more reliable. 30 Years Quality Solution & Service Portable and Laboratory Instruments The accuracy and reliability of the Suntex portable and Laboratory instruments is guaranteed by the online measurement experience. Suntex provides a variety of ph/orp, Conductivity/Resistivity/TDS/ Salinity portable and benchtop meters to universities, research centers, environment inspection labs, and applications of various industries. There are also Colony Counter, COD Thermoreactor, Hotplate & Stirrer, and Automatic Waterstill for most of general laboratories usage. ISO 9001: 2000 Certificated since 2001 Suntex has been certificated by TUV Management Service GmbH, Germany since 2001 for Distribution of Instruments & Equipments and Development and Production of Meters & Transmitters. 2
3 Main Applications Wastewater PC-3100 Pure water EC-430/410 Industrial Process PC-3110 Cooling water / Boiler water / Scrubber EC-4110 Application table for parameters of SUNTEX online transmitters ph/orp Cond/Res D.O. Cl2 Turb/S.S ION Wastewater Pure water Cooling water Boiler water Scrubber Surface water Drinking water Electronics Industry Chemical Industry Food & Beverage Industry Pharma Industry Fish farm Swimming Pool 3
4
5
6
7 ph/orp How to build a ph Measurement System G F C E D B A A Immersion system in open basin B Measurement in very variable water levels, or lakes with a float C Flow-through system D 1/2 & 3/4 pipe mounted system E 1 pipe mounted system F Side-entry system in vessel G Top-entry system in closed vessel There are four major elements to make a complete measurement system. 1. Transmitter: to translate the sensor s reading into a displayed measurement and transfer the data to the process control system 2. Sensor: directly mounted in the field to measure solutions 3.Cable: to transmit the signal between a sensor and a transmitter 4.Sensor Housing: to hold the sensor, protect the sensor in the measurement solutions, and to connect to the extension cable 7
8 SUNTEX Intelligent Transmitter PC-3110RS 7 Intelligent Value-Added Features Trace mode Set up from 3 mins to four weeks duration of the measured value trend graph to help you master the process history 1 Real-time chart mode 3 minutes real-time dynamic graph to help you realize recent development in control 2 RS-485 MODBUS protocol Provides long-distance, multiple values and configuration info transmission and anti-electrical signal protection 3 Events logbook Actions, current output out of range, power outages and error records, no need for standby and record them anymore 4 8
9 The all new intelligent transmitter's user-friendly interface and intelligent information design, making the RS model not just for RS-485 communication. It not only allows settings of RS-485 digital transmission easier, but also provides trace record map, real-time dynamic graphics display in the measurements mode; for calibration, it provides 5-point regression calculation calibration, product adjustment and user-tailored ph/temp. data table calibration mode. There is also a 50 events logbook for user to realize all the actions, current out of range, power outage, entries of setup & calibration menu, and error occurrences for users to master the whole situation. The new PC-3110RS makes the functional designs of intelligent transmitters to the extreme, to meet customers' requirement of ease of operation and the maximization of process safety, and will position Suntex transmitter in the leader of quality and innovation. 5 points calibration & regression calculation Accurate, wide-range calibration to improve your process safety 5 Product adjustment Measured value can be adjusted to the same as lab sample value to eliminate error concerns 6 ph/temp. Define cal. mode Accept all kinds of standard buffers, self-built 5 ph/temp. data table, and directly auto calibration with user-tailored buffer settings 7 9
10 Applications: Industrial Process Chemical Process Water & Wastewater Treatment Biochemistry Scrubber Recycling Environmental protection Features: 96 x 96mm Intelligent ph/orp Transmitter Waterproof and dustproof design Solution-ground design eliminating interference of ground potential Large LCM with auto-sense backlight and contrast setting function User-friendly operation with text and graphic illustration, clear signs and easy to understand Multi-Cal calibration, Tech. and NIST buffer automatic recognition Max. 3-point calibration and the calibration line calculated by linear regression, the last calibration data displayable With password and multi-key design-security protection enhancement Automatic temperature compensation, NTC30K or PT 1000 selectable Two sets of isolated current output at DC 0/4~20mA, max. load 500Ω Hi/Lo, Hi/Hi, Lo/Lo selectable two limited contact outputs with programmable set-points and hysteresis Gradually continuous sample measurements average function to enhance stability Automatic sensor clean function with programmable time interval LED indicated alarm or washing status signal IP 65 (NEMA 4X) CE approved PC-3110RS / PC-3110RS-P Only: Measuring value can be selected for figure or chart display Trace mode can display historical measured value curve from 3-minute to 4-week program Equipped with logbook function Max. 5-point calibration, with customer definition buffer setting and calibration curve, which can be displayed Equipped with one analog output and RS-485 interface Field correction function Product adjustment function for field correction 10 PC-3110-P / PC-3110RS-P Only: Equipped with PID control function to maximize the stability of process
11 PC-3110/PC-3110RS Specifications: PC-3110 PC-3110-P PC-3110RS PC-3110RS-P Measuring modes Ranges Resolution ph ORP Temp. ph ORP Temp. ph Accuracy ORP Temp. Repeatability Temperature compensation Ambient Temperature Input Impedance Display Analog output 1 ph/orp/temp ~16.00 ph -1999~1999 mv -30.0~ ph 1 mv 0.1 ± 0.01 ph ± 1 digit ± 0.1% ±1 digit ± 0.2 ±1 digit ±0.05pH Automatic with NTC 30KΩ or PT-1000 Manual adjustment 0~50 >10 12 Ω Large LCM with auto-sense backlight and contrast function Text mode Text, Chart or Trace mode Isolated DC 0/4~20mA corresponding to ph/orp, max. load 500Ω Analog output 2 Isolated DC 0/4~20mA corresponding to Temp., max. load 500Ω - Serial Interface - RS-485(MODBUS RTU or ASCII) Logbook - 50 data records Calibration mode Setting Activate Any, Tech & NIST, Three Points 240VAC, 0.5A max. (recommend) Any, Tech, NIST & Custom definition buffer setting table, Five Points Hi/Lo, Hi/Hi, Lo/Lo selectable two limited programmable, ON/OFF - *PID Control - *PID Control Wash 240VAC, 0.5A max. (recommend) Time ON:0~99min.59sec. OFF:0~999 hours59min. Voltage output DC ± 12V, 1W max. Power Supply 100~240VAC±10%, 9W max., 50/60 Hz Installation Wall or pipe or panel mounting Dimensions 96 mm x 96 mm x 132 mm (H x W x D), 1/4 DIN Cut off Dimensions 93 mm x 93 mm (H x W) Weight 0.5 kg Protection IP 65 (NEMA 4X) *PID Control Function: P, PI, PD, PID control *PID Control Output: Pulse Length, Pulse Frequency, Analogout What s included? 2 Panel Mounting clips, ph 4, ph 7 buffer solutions, Plastic L shaped electrode holder support, Precision driver for wiring Optional Accessories: ph electrode 2. ORP electrode PT-1000 ATC probe 4. NTC 30KΩ ATC probe 5. Field indication transmitter 6. ph buffer solutions 7. ORP buffer solutions 8. Cleaning solutions 9. Junction box 10. Flow-through chamber 11. Immersion electrode holder 1M, 2M and 3M 12. Industrial electrode protection housing/fitting 13. Extension cable 14. Sensor cleaning kit Sun shield Stainless holder support base
12 Applications: RO System Cooling water Industrial process Features: Pure water Boiler water Water treatment 2-Electrode 96 x 96mm Intelligent conductivity/resistivity transmitter Waterproof and dustproof design Compatible with conductivity or resistivity measurement 4-Electrode Compatible with 2- or 4-electrode conductivity cell User-friendly operation with text and graphic illustrations, clear signs and easy to understand Large LCM with auto-sense backlight and contrast setting function With password and multi-key design-security protection enhancement Automatic temperature compensation with NTC30K or PT1000 Temperature coefficient compensation by non-linear or linear Two sets of isolated current output at DC 0/4~20mA, max. load 500Ω Hi/Lo, Hi/Hi, Lo/Lo selectable two limited contact outputs with programmable set-points and hysteresis Gradually continuous sample measurements average function to enhance stability Automatic sensor clean function with programmable time interval LED indicated alarm or washing status signal IP 65 (NEMA 4X) EC-4110RS only: Measuring value can be selected for figure or chart display Trace mode can display historical measured value curve from 3-minute to 4-week program Equipped with logbook function Equipped with one analog output and RS-485 interface 12
13 EC-4110/EC-4110RS Specifications: Range Resolution EC-4110 EC-4110RS Measuring modes Conductivity/Resistivity Conductivity 0.00 us/cm~200.0 ms/cm in 5 ranges; Auto or Fixed Resistivity 0.00~20.00 MΩ cm Temp ~130.0 Conductivity 0.01 / 0.1 / 1 μs/cm 0.01 / 0.1 ms/cm Resistivity 0.01 MΩ cm Temp. 0.1 Conductivity ± 1% (± 1 digit) Accuracy Resistivity ± 1% (± 1 digit) Temp. ± 0.2 (± 1 digit) Cell constant cm -1 fixed, freely selectable ~19.99 cm -1 Calibration Temperature compensation Automatic with three kinds of built-in standard solutions Manual cell-constant adjustment Automatic with NTC 30K / PT 1000 or manual adjustment Temperature coefficient Linear compensation at 0.00%~40.00% Non-linear compensation for natural water Ambient temperature 0~50 Storage temperature -10~70 Setting Display Analog output 1 Large LCM with auto-sense backlight and contrast function Text mode Text, Chart or Trace mode Isolated DC 0/4~20mA corresponding to measuring range, max. 500Ω Analog output 2 Isolated DC 0/4~20mA corresponding to temperature, max. 500Ω - Serial interface - RS-485 (MODBUS RTU or ASCII) Logbook - 50 data records Activate 240VAC, 0.5A max. (recommend) Hi/Lo, Hi/Hi, Lo/Lo selectable two limited programmable, ON/OFF Wash 240VAC, 0.5A max. (recommend) Activate ON:0~99 min. 59 sec. OFF:0~999 hours 59 min. Power supply 100~240VAC ± 10%, 5W max., 50/60 Hz Installation Wall or pipe or panel mounting Dimensions 96 mm x 96 mm x 132 mm (H x W x D), 1/4 DIN Cut out dimensions 93 mm x 93 mm (H x W) Weight 0.5 Kg Protection IP 65 (NEMA 4X) What s included? 2 Panel Mounting clips, Precision driver for wiring Optional accessories: 1. 2-electrode conductivity cell 2. 4-electrode conductivity cell 3. Resistivity cell, 0.01/0.05/ Specific cable 5M, 10M, 20M, 30M or other length upon request 5. Standard solution, 84/1413us and 12.88ms 6. Flow through tees 7. Flow chamber 8. Sun shield 9. Immersion sensor holder 1M, 2M, and 3M 10. L shaped sensor holder support base
14 Applications: Water and wastewater treatment Fermentation Industrial Process Environment Features: 96 x 96mm Intelligent D.O. transmitter Waterproof and dustproof design Compatible with WTW TriOxmatic D.O. sensors or Mettler Toledo InPro D.O. sensors Measuring unit: %, ppm, mg/l Salinity correction & Atmospheric pressure correction User-friendly operation with text and graphic illustration, clear signs and easy to understand Large LCM display with auto-sense backlight and contrast setting function Sensor slope performance display Sensor self diagnosis for TriOxmatic 700 D.O. sensor Simultaneous display of measurement value and temperature Automatic temperature compensation Two sets of isolated current output DC 0/4~20mA, Max.500Ω Hi/Lo, Hi/Hi, Lo/Lo selectable two limited contact outputs with programmable set-points and hysteresis Gradually continuous sample measurements average function to enhance stability With password and multi-key design-security protection enhancement Automatic sensor clean function with programmable time interval LED indicated alarm or washing status signal IP 65 (NEMA 4X) WTW D.O. sensor Mettler Toledo D.O. sensor DC-5110RS only: Measuring value can be selected for figure or chart display Trace mode can display historical measured value curve from 3-minute to 4-week program Equipped with logbook function Equipped with one analog output and RS-485 interface 14
15 DC-5110/DC-5110RS Specifications: DC-5110 DC-5110RS Measuring mode Measuring range Resolution % / ppm / mg/l / TEMP. % 0 ~ 600% (Depends on the sensor) mg/l 0~60.00 mg/l (Depends on the sensor) ppm 0~60.00 ppm (Depends on the sensor) Temp. 0~140 C (Depends on the sensor) % 0.1 % mg/l 0.01 mg/l / mg/l ppm 0.01 ppm / ppm Temp. 0.1 % mg/l Accuracy ppm Temp. Temperature Compensation Salinity correction Pressure correction Ambient temperature Storage temperature Display Analog output 1 ±0.5%±1Digit ±0.2 C±1Digit with temperature error correction function NTC 30K or NTC 22K automatic compensation or manual adjustment 0.0 ~ 45.0 ppt ~ bar / 7.25 ~ psi / 500~2500 mmhg manual adjustment 0~50 C -10~70 C Large LCM with auto-sense backlight sensor for auto contrast function Text mode Text, Chart or Trace mode Isolated DC 0/4~20mA corresponding to measurement, max. load 500Ω Analog output 2 Isolated DC 0/4~20mA corresponding to temperature, max. load 500Ω - Serial interface - RS-485 (MODBUS RTU or ASCII) Logbook - 50 event records Setting 240VAC, 0.5A Max. (recommend) Activate Hi/Lo, Hi/Hi, Lo/Lo selectable two limited programmable, ON/OFF Wash 240VAC, 0.5A Max. (recommend) Time ON:0~99min. 59 sec. OFF:0~999 hours 59 min. Voltage output DC±8V Max. 0.5W Power supply 100V~240VAC ±10%~50/60Hz, 5W max. Installation Wall or Pipe or Panel mounting Dimensions 96 mm 96 mm 132 mm (H W D), 1/4 DIN Cut out dimensions 93 mm 93 mm (H W) Weight 0.5Kg Protection IP 65 (NEMA 4X) What s included? 2 Panel Mounting clips, Plastic L shaped electrode holder support, Precision driver for wiring Optional accessories: 1. D.O. sensor 2. Membrane kit 3. Electrolyte 4. Cleaning solution 5. Immersive protection holder 1M, 2M and 3M 6. Junction box 7. Extension cable 8. Auto clean kit 9. Stainless holder support base
16 ph/orp PC-3100 ph/orp Transmitter Robust protection and precise integration The PC-3100 series ph/orp transmitter has rugged IP 65 enclosure and can be wall, panel, pipe mounted for installation in almost any industrial application. The PC-3100RS offers RS-485 interface to support digital communication to your PLC. The transmitters inherit our reliable technology which features in accurate, robust, and easy to use functions. Applications: Water treatment Chemical process Biochemical process Wastewater treatment Electrical process Food and beverage process Features: ph, ORP, Temperature measurement IP 65 waterproof and dustproof design Back-lit LCD with ON/OFF/Auto programmable illumination Two sets of isolated current output DC 0/4~20mA corresponding to measurement and temperature Two Hi/Lo Limited contact outputs; Set points with programmable hysteresis function Automatic temperature compensation Gradually continuous sample measurements average function to enhance stability Wash function with programmable time-interval control LED indication alarm or wash status signal Password protection PC-3100RS with one analog output and one RS-485 interface PC-3100 PC-3100RS ph Measuring ORP range Temperature Temperature Compensation Input impedance Display Analog output ~ ph, ±0.01 (± 1Digit) ~ 1999 mv, ±1mV (± 1Digit) -30.0~130.0 C, ±0.2 C (± 1Digit) Automatic with PT-1000 or NTC 30K or manual adjustment Ω Back-lit LCD display with auto-sense on/off/auto illumination Isolated DC 0/4~20 ma corresponding to measurement, max load 500Ω Analog output 2 Isolated DC 0/4~20 ma corresponding to temperature, max load 500Ω - Serial interface - RS-485 (MODBUS RTU or ASCII) Calibration mode Any, Tech & NIST buffer, Two points Any, Tech & NIST buffer,three points Setting Activate 240 VAC, 0.5A max. (recommend) Hi/Lo two limited programmable relay outputs, ON/OFF Wash 240 VAC, 0.5A max. (recommend) Time ON: 0~9999 sec. / OFF: 0~999.9 hours Ambient temperature 0 ~ 50 C Storage temperature -20 ~ 70 C Voltage output DC ±12V Power Supply 100V~240VAC±10% 50/60Hz Installation Wall mounting, Pipe mounting, Panel mounting Dimensions 144 mm x 144mm x 115 mm (H x W x D), 1/2 DIN Cut off dimensions 138 mm x 138 mm (H x W) Weight 0.8 kg Protection IP 65 (NEMA 4X) What s included? 4 Panel mounting clips, ph4, ph7 buffer solutions, Plastic L shaped electrode holder support base 16
17 Conductivity EC-4300 Conductivity Transmitter Perfect integration with salinity measurement The EC-4300 series conductivity transmitter has rugged IP 65 enclosure and can be wall, panel, pipe mounted for installation in almost any industrial application. The EC-4300RS offers RS- 485 interface to support digital communication to your PLC. The transmitters inherit our reliable technology which features in accurate, robust, and easy to use functions. Applications: RO System Cooling Water Industrial Process Boiler Feed Water Ultra Pure Water System Water Treatment Features: Conductivity, Resistivity, Salinity, Temperature measurement IP 65 waterproof and dustproof design Back-lit LCD with ON/OFF/Auto programmable illumination Two set of isolated current output DC 0/4~20mA corresponding to measurement and temperature Hi/Lo Limited contact output; Set point and hysteresis programmable Automatic temperature compensation Gradually continuous sample measurements average function to enhance stability Wash function with programmable time-interval control LED indication alarm or wash status signal Password protection EC-4300RS with one analog output and one RS-485 interface EC-4300 EC-4300RS Conductivity 0.000μS/cm~200.0 ms/cm in 6 ranges / Auto, ±1% (± 1Digit) Measuring Resistivity 0.00~20.00MΩ cm, ±1% (± 1Digit) range Salinity 0.0~70.0 ppt, ±1% (± 1Digit) Temperature -30.0~130.0 C, ±2 C (± 1Digit) Cell constant 0.01, 0.1, 0.5, cm -1 fixed, freely selectable ~19.99cm -1 Temperature Compensation Automatic with PT-1000 or NTC 30K or manual adjustment Temperature coefficient Linear compensation from 0.00~20.00% Non-Linear Compensation for natural water Display Back-lit LCD display with auto-sense on/off/auto illumination Analog output 1 Isolated DC 0/4~20 ma corresponding to measurement, max load 500Ω Analog output 2 Isolated DC 0/4~20 ma corresponding to temperature, max load 500Ω - Serial interface - RS-485(MODBUS RTU or ASCII) Setting Activate 240 VAC, 0.5A max. (recommend) Hi/Lo two limited programmable relay outputs, ON/OFF Wash 240 VAC, 0.5A max. (recommend) Time ON: 0~9999 sec. / OFF: 0~999.9 hours Ambient temperature 0 ~ 50 C Storage temperature -20 ~ 70 C Power Supply 100 ~ 240 VAC ±10%, 50~60 Hz Installation Wall mounting, Pipe mounting, Panel mounting Dimensions 144mm x 144mm x 115 mm (H x W x D), 1/2 DIN Cut off dimensions 138mm x 138 mm (H x W) Weight 0.8 kg Protection IP 65 (NEMA 4X) What s included? 4 Panel mounting clips 17
18 Dissolved Oxygen DC-5300 D.O. Transmitter Precise calculation in various applications The DC-5300 D.O. transmitter has rugged IP 65 enclosure and can be wall, panel, and pipe mounted for installation in mainly wastewater, fish farm, environment and fermentation applications. Its excellent signal processor and precise salinity and pressure compensation make DC the extremely powerful instruments you can trust. Applications: Wastewater treatment Fish Cultivation Environment Fermentation Features: Concentration and saturation of dissolved oxygen measurement Measurement unit: ppm, mg/l, %, C Compatible with WTW TriOxmatic 690 & 700, and Mettler Toledo InPro 6050 & 6800 sensors Back-lit LCD with ON/OFF/Auto programmable illumination Two sets of isolated current output DC 0/4~20mA corresponding to measurement and temperature Two Hi/Lo Limited contact outputs; Set points with programmable hysteresis function Salinity correction & atmospheric pressure correction Gradually continuous sample measurements average function to enhance stability Wash function with programmable time-interval control Display of the last calibration time and sensor slope Password protection DC-5300RS with one analog output and one RS-485 interface 18 DC-5300 DC-5300RS 0.0 ~ 600.0%, (Depends on the sensor) % ±0.5% of reading(± 1Digit) Measuring 0.00~60.00 ppm, (Depends on the sensor) range ppm ±0.5% of reading(± 1Digit) & 0.00~60.00 mg/l, (Depends on the sensor) Accuracy mg/l ±0.5% of reading(± 1Digit) Temperature 0.0~140.0 C, (Depends on the sensor), ±0.2 C (± 1Digit) Temperature Compensation 0~50 C NTC 30K or NTC 22K automatic compensation 0~50 C manual adjustment Salinity correction 0.0 ~ 45.0 ppt Pressure correction ~ bar or 7.25 ~ psi manual adjustment Display Back-lit LCD display with auto-sense on/off/auto illumination Calibration mode One point or two points calibration Analog output 1 Isolated DC 0/4~20 ma corresponding to measurement, max load 500Ω Analog output 2 Isolated DC 0/4~20 ma corresponding to temperature, max load 500Ω - Serial interface - RS-485(MODBUS RTU or ASCII) Setting 240 VAC, 0.5A max. (recommended) Activate Hi/Lo two limited programmable relay outputs, ON/OFF Wash 240 VAC, 0.5A max. (recommended) Time ON: 0~9999 sec. / OFF: 0~999.9 hours Ambient temperature 0 ~ 50 C Storage temperature -20 ~ 70 C Voltage output DC ±8V, Max 0.5W Power Supply 100 ~ 240 VAC±10%, 50~60 Hz Installation Wall mounting, Pipe mounting, Panel mounting Dimensions 144 mm x 144mm x 115 mm (H x W x D), 1/2 DIN Cut off dimensions 138 mm x 138 mm (H x W) Weight 0.8 kg Protection IP 65 (NEMA 4X) What s included? 4 panel mounting clips, Plastic L-shaped electrode holder support base
19 Chlorine/Ozone CT-6300 Chlorine/Ozone Transmitter Extremely powerful and valuable The CT-6300 transmitter has rugged IP 65 enclosure and can be wall, panel, pipe mounted in almost any industrial application. When compatible with residual chlorine electrodes or ozone electrode, the complete system is extremely powerful of detecting the free chlorine or ozone in drinking water, swimming pool applications. The transmitter inherits our reliable technology which features in accurate, robust, and easy to use functions. Applications: Swimming pool Drinking water Industrial process Water treatment Features: Sensor type: Both two-wire and four-wire compatible Automatic function: auto cal, self-test, and error code indication IP 65 waterproof and dustproof design Back-lit LCD with ON/OFF/Auto programmable illumination Two sets of isolated current output DC 0/4~20mA corresponding to measurement and temperature Two Hi/Lo Limited contact outputs; Set points with programmable hysteresis function Automatic temperature compensation Gradually continuous sample measurements average function to enhance stability Wash function with programmable time-interval control LED indication alarm or wash status signal Display of the last calibration time and sensor slope Password protection CT-6300RS with one analog output and one RS-485 interface CT-6300 CT-6300RS Measuring mode Residual Chlorine / O 3 / Temperature Cl ~ ppm(mg/l) ±0.5%±1Digit, depends on sensor Measuring O ~20.00 ppm(mg/l) ±0.5%±1Digit, depends on sensor range Temperature -10 ~ 110 C ±0.2 C Resolution 0.01ppm(mg/l), 0.1 C Temperature compensation Automatic with PT-1000 / NTC-30K or manual adjustment Display Back-lit LCD display with auto-sense on/off/auto illumination Analog output 1 Isolated DC 0/4~20 ma corresponding to measurement, max load 500Ω Analog output 2 Isolated DC 0/4~20 ma corresponding to temperature, max load 500Ω - Serial interface - RS-485(MODBUS RTU or ASCII) Setting 240 VAC, 0.5A max. (recommended) Activate Hi/Lo two limited programmable relay outputs, ON/OFF Wash 240 VAC, 0.5A max. (recommended) Time ON: 0~9999 sec. / OFF: 0~999.9 hours Ambient temperature 0~50 C Storage temperature -20~70 C Voltage output DC±8V Max. 0.5W Power Supply 100V ~ 240VAC±10%, 50/60Hz Installation Wall mounting, Pipe mounting, Panel mounting Dimensions 144 mm x 144mm x 115 mm (H x W x D), 1/2 DIN Cut off dimensions 138 mm x 138 mm (H x W) Weight 0.8 kg Protection IP 65 (NEMA 4X) What s included? 4 Panel mounting clips 19
20 Turbidity/SS TC-7100 Turbidity/SS Transmitter Robust protection and precise integration The TC-7100 series Turbidity / Suspended solids transmitter has rugged IP 65 enclosure and can be wall, panel, pipe mounted for installation in almost any industrial application. The TC-7100RS offers RS-485 interface to support digital communication to your PLC. The transmitters inherit our reliable technology which features in accurate, robust, and easy to use functions. Applications: Water treatment Surface water Wastewater treatment Industrial process Features: Turbidity, Suspended solids, and Temperature measurement 5 points calibration IP 65 waterproof and dustproof design Back-lit LCD with ON/OFF/Auto programmable illumination Isolated current output DC 0/4~20mA corresponding to measurement Two Hi/Lo Limited contact outputs ; Set points with programmable hysteresis function Gradually continuous sample measurements average function to enhance stability Wash function with programmable time-interval control LED indication alarm or wash status signal Password protection TC-7100 Measuring unit Turbidity: NTU, FTU, FNU Suspended solids: ppm, mg/l Measuring range Depends on sensors(0~100ntu, 0~500NTU, 0~3000NTU, 0~1000ppm) Resolution AUTO. (0.01/ 0.1/ 1) Signal average interval 0~60 sec. selectable / default 30 sec. Display Back-lit LCD display with auto-sense on/off/auto illumination Analog output Isolated DC 0/4~20 ma corresponding to measurement, max load 500Ω Setting Activate 240 VAC, 0.5A max. (recommended) Hi/Lo two limited programmable relay outputs, ON/OFF Wash 240 VAC, 0.5A max. (recommended) Time ON: 0~9999 sec. / OFF: 0~999.9 hours Ambient temperature 0 ~ 50 C Storage temperature -20 ~ 70 C Voltage output DC ±12V Power Supply 100V~240VAC±10%, 50/60Hz Installation Wall mounting, Pipe mounting, Panel mounting Dimensions 144 mm x 144mm x 115 mm (H x W x D), 1/2 DIN Cut off dimensions 138 mm x 138 mm (H x W) Weight 0.8 kg Protection IP 65 (NEMA 4X) What s included? 4 Panel mounting clips 20
21 Ion Selective IT-8100 ION Transmitter Proven performance for demanding field The IT-8100 Ion transmitter has rugged IP 65 enclosure and can be wall, panel, pipe mounted in almost any industrial application. When compatible with fluoride ion selective electrodes, the complete system is extremely powerful of detecting the F - ion in wastewater of semiconductor, solar panel, LCD industries. The transmitter inherits our reliable technology which features in accurate, robust, and easy to use functions. Applications: Wastewater treatment of semiconductor, solar panel, and LCD industries Features: ISE method of ion measurement provides excellent selectivity Automatic function: auto cal, self-test, and error code indication IP 65 waterproof and dustproof design Back-lit LCD with ON/OFF/Auto programmable illumination Two sets of isolated current output DC 0/4~20mA corresponding to measurement and temperature Two Hi/Lo Limited contact outputs; Set points with programmable hysteresis function Automatic temperature compensation Gradually continuous sample measurements average function to enhance stability Wash function with programmable time-interval control LED indication alarm or wash status signal Password protection IT-8100 Method Ion Selective electrode method Ion type X -- / X - / X + / X ++ Measuring unit mv / ppm / mg/l Concentration 0.00~20.00 / 0.0~200.0 / 0~2000 / 0~20000 / Auto range Measuring mv ~ ±0.01% range Temperature -10 ~ 110 C ±0.2 C Resolution (ppm) Auto (0.01 / 0.1 / 1) ppm Temperature compensation Automatic with PT-1000 / NTC-30K or manual adjustment Calibration mode Two or three points calibration, Offset calibration (13 range selectable) Display Back-lit LCD display with auto-sense on/off/auto illumination Analog output 1 Isolated DC 0/4~20 ma corresponding to measurement, max load 500Ω Analog output 2 Isolated DC 0/4~20 ma corresponding to temperature, max load 500Ω Setting 240 VAC, 0.5A max. (recommended) Activate Hi/Lo two limited programmable relay outputs, ON/OFF Wash 240 VAC, 0.5A max. (recommended) Time ON: 0~9999 sec. / OFF: 0~999.9 hours Ambient temperature 0~50 C Storage temperature -20~70 C Voltage output DC ±12V Power Supply 100V~240VAC±10%, 50/60Hz Installation Wall mounting, Pipe mounting, Panel mounting Dimensions 144 mm x 144mm x 115 mm (H x W x D), 1/2 DIN Cut off dimensions 138 mm x 138 mm (H x W) Weight 0.8 kg Protection IP 65 (NEMA 4X) What s included? 4 Panel mounting clips, Plastic L shaped electrode holder support base 21
22 Conductivity How to build a Conductivity Measurement System F B E C D A A Immersion system in open basin B Flow-through system C 1/2 pipe mounted system D 3/4 pipe mounted system E Side-entry system in vessel F Top-entry system in closed vessel There are four major elements to make a complete measurement system 1. Transmitter: to translate the sensor s reading into a displayed measurement and transfer the data to the process control system 2. Sensor: directly mounted in the field to measure solutions 3. Cable: to transmit the signal between a sensor and a transmitter 4. Sensor Connection: to install the sensor and connect to the system, and protect the sensor in the measurement solutions 22
23 Conductivity Illustration of Sensor Installation 2-Electrode Sensor 4-Electrode Sensor Correct Installation Less than 28 mm Less than 28 mm Flow Flow To avoid bubbles To avoid bubbles Incorrect Installation Insufficient immersion Insufficient immersion Flow Flow Insufficient immersion Insufficient immersion Flow Flow 23
24 ph/orp PC-100/PC-110 ph/orp Panel Meter Compact and Pragmatic The PC-100 & PC-110 ph/orp monitors utilize microprocessor technology to provide you enhanced capabilities with economical price. Furthermore, they can be used as a second meter for receiving mv, or ma signal from other transmitter and show with various of measurement units. The PC-100 features for sample monitoring and the PC-110 offers one relay output to sufficiently activate your process system. Applications: Water treatment Pure water System Clean room Wastewater treatment Scrubber Electronics process Features: 48 x 96 mm Microprocessor ph/orp Monitor & Controller As a second meter to receive mv, ma signal from other transmitter User-friendly operation Automatic temperature compensation Compatible with Pt-1000 and NTC 30K temperature probe Isolated current output DC 0/4~20mA Gradually continuous sample measurements average function to enhance stability PC-110 offers one relay contact output, one set point with programmable hysteresis function PC-100 PC-110 ph Measuring ORP Range Temperature & Accuracy mv ma Measurement unit on display Temperature Compensation Input impedance Display Analog output ~ ph, ±0.01pH (± 1Digit) ~ 1999 mv, ±0.1% (± 1Digit) -30.0~110 C, ±0.1 C -2000~+2000mV ±0.1%(±1Digit) 0.00~20.00mA ±0.1%(±1Digit) ph, μs/cm, ms/cm, MΩ cm, mg/l, ppm, C, F, %, mv, ma, None unit Automatic with PT-1000 or NTC 30K or manual adjustment Ω LCD display Isolated DC 0/4~20 ma corresponding to measurement, max load 500Ω Setting VAC, 0.5A max. Activate - Hi/Lo one relay output Working temperature 0~50 C Storage environment -20~70 C Power Supply 100V~240VAC±10%, 50/60Hz Installation Panel mounting Dimensions 48 mm x 96mm x 110 mm (H x W x D), 1/8 DIN Cut off dimensions 44 mm x 92 mm (H x W) Weight 0.25 kg What s included? 2 Panel mounting clips 24
25 Conductivity EC-410/EC-430 Conductivity Monitor Compact and Pragmatic The EC-410 & EC-430 conductivity monitors utilize microprocessor technology to provide you enhanced capabilities with economical price. The compact design fits in small space installation. The EC-410 features for water quality monitoring and the EC-430 offers one relay output to sufficiently activate your process system. Applications: RO System Cooling Water Industrial Process Boiler Feed Water Pure Water System Water Treatment Features: 48 x 96 mm Microprocessor Water Quality Monitor & Controller Compatible with both Conductivity and resistivity measurement Compatible with 2-Electrode or 4-Electrode Sensors Automatic temperature compensation Compatible with Pt-1000 and NTC 30K temperature probe Linear and non-linear temperature coefficient Isolated current output DC 4~20mA Gradually continuous sample measurements average function to enhance stability EC-430 offers one relay contact output, one set point with programmable hysteresis function EC-410 EC-430 Measuring Conductivity 0.00μS/cm~200.0 ms/cm in 5 ranges, ±1% (± 1Digit) Range Resistivity 0.00~20.00MΩ cm, ±1% (± 1Digit) & Accuracy Temperature -10~110.0 C, ±0.5 C Cell constant 0.01, 0.05, 0.1, 0.5, cm -1 fixed, freely selectable 0.008~19.99cm -1 Temperature Compensation Automatic with PT-1000 or NTC 30K or no compensation Temperature Conductivity coefficient Resistivity Display Analog output Non-Linear Compensation Linear compensation from 0.00~40.00% Non-Linear Compensation LCD display Isolated DC 4~20 ma corresponding to measurement, max load 500Ω Setting VAC, 0.5A max. Activate - Hi/Lo one relay output Ambient temperature 0 ~ 50 C Storage temperature -20 ~ 70 C Power Supply 100V~240VAC±10%, 50/60Hz Installation Panel mounting Dimensions 48 mm x 96mm x 110 mm (H x W x D), 1/8 DIN Cut off dimensions 44 mm x 92 mm (H x W) Weight 0.25 kg What s included? 2 Panel mounting clips 25
26 Accessories ph/orp Transmitter Accessories PH-300T Accessional ph / ORP Transmitter The PH-300T accessional ph/orp transmitter is designed for signal conversion when distance from sensor to original transmitter is over than 30m, or when environment is interfered by electromagnetic and so on. 26 Sensor Protection Holders PP-100A PP-100A PP-100AN PP-100AP PP-100AE Protective Electrode Holder for ph/orp electrode, 1M Incl. Waterproof cap Protective Electrode Holder for ph/orp electrode, 1M Incl. Junction Box Protective Electrode Holder for ph/orp electrode with NTC 30K temperature probe, 1M, Incl. Junction Box Protective Electrode Holder for ph/orp electrode with PT-1000 temperature probe, 1M, Incl. Junction Box Protective Electrode Holder for ph/orp electrode with solution ground, 1M, Incl. Junction Box Extension cable for sensors RG-58 Extension cable for ph/orp sensor (per meter) F94009-BK Extension cable for ph/orp sensor with temperature probe or solution ground probe (per meter) Electrode housings 8-IF03 ph/orp sensor inline housing 8-TF03 ph/orp sensor bypass chamber Protection holder s accessories A Stainless L Shaped Electrode Holder Support Base( Stainless Support Base is designed for PP Electrode Holders which length is longer than 1 meter; or for PP Electrode Holders which are immersed in a running basin.) 8-CH-10 ph/orp sensor auto clean kit 8-SF01 Protection holder float for measurement in variable water levels or in lakes, etc. Standard buffers 8-03 Buffer solution, ph4.00, 500 ml 8-04 Buffer solution, ph7.00, 500 ml 8-23 Buffer solution, ph10.00, 500ml mol/l KCl solution, 60ml mol/l KCl solution, 500ml Simulator PS150 ph/mv signal simulator Sun shield Sun Shield with Pipe Mounting kit Sun Shield with Wall Mounting kit
27 Conductivity 8-24X Series Conductivity Sensor 4-Electrode Design The 8-24X series conductivity sensors apply the state of art 4-Electrode measurement principle to accurately measure medium to high conductivity solutions. Its modular cable and sensor design provides the most convenience of sensor re-installation. The sensor is a HF resistant one, while the sensor can stand higher temperature up to 120 C. Specifications / (gray) 8-242(light yellow) Type 4-electrode sensor 4-electrode sensor 4-electrode sensor Range (μs/cm) 1.00μs~200.0ms/cm 1.00μs~200.0ms/cm 1.00μs~200.0ms/cm Working Temp. 0~80 C 0~80 C 0~120 C Pressure range at 25 C (77 ) 0~7 bar 0~7 bar 0~7 bar Electrode Material Titanium, CPVC Monel, CPVC Titanium, PVDF Body Material CPVC CPVC PVDF HF Resistant electrode - Yes - Temperature Sensor NTC 30K NTC 30K NTC 30K Cell Constant 0.5 cm cm cm -1 Process Connection 3/4" NPT 3/4" NPT 3/4" NPT Insertion length 40 mm 40 mm 40 mm Max. length 120 mm 120 mm 120 mm Compatible, Cable length 5, 10, 20, 30m 5, 10, 20, 30m 5, 10, 20, 30m Accessory Sensor Connection 8-TF01 3/4 T-Connector Cable Cable length 5 m 10 m 20 m 30 m T-Connector Ø22mm 0.87" 40mm 1.57" 120mm 4.72" 3/4" NPT 8-24X Series Cable 27
28 Conductivity 8-22X Series Resistivity Sensor 2-Electrode Design The 8-22X series resistivity sensors are designed for measuring very low conductivity solutions. With different cell constant, the 8-22X sensors provide different range of the ultra-pure/pure water measurement. Its modular cable and sensor design provides the most convenience of sensor re-installation. 8-22X Series Specifications Type 2-electrode sensor 2-electrode sensor 2-electrode sensor Typical application Ultra-pure water Pure water R.O. system Range (μs/cm) (MΩ cm) 0.05μs~20.0μs/cm 0.00~20.0MΩ cm 0.05μs~100.0μs/cm 0.00~20.0MΩ cm 0.1μs~200.0μs/cm 0.00~10.0MΩ cm Working Temp. 0~80 C 0~80 C 0~80 C Pressure range at 25 C (77 ) 0~7 bar 0~7 bar 0~7 bar Electrode Material Titanium Titanium Titanium Body Material CPVC CPVC CPVC Temperature Sensor NTC 30K NTC 30K NTC 30K Cell Constant 0.01 cm cm cm -1 Process Connection 3/4" NPT 3/4" NPT 3/4" NPT Insertion length 63 mm 63 mm 48 mm Max. length 144 mm 144 mm 129 mm Compatible, Cable length 5, 10, 20, 30m 5, 10, 20, 30m 5, 10, 20, 30m T-Connector Bypass chamber Accessory Sensor Connection 8-TF01 8-TF02 3/4 T-Connector 3/4 NPT bypass chamber Cable Cable length 5 m 10 m 20 m 30 m Cable 144mm 129mm 63mm 2.48" 48mm Ø17mm 0.67" Ø17mm 0.67" C = 0.1 3/4" NPT 3/4" NPT 8-221/ CELL CONSTANT 28
29 Conductivity Fixed Cable Resistivity Sensor 8-11 Series Resistivity Cell The 8-11 Series resistivity cells feature in both economical and robust design. The cells are designed for measuring in very low conductivity solutions of resistivity measurement Series Specifications Type 2-electrode sensor 2-electrode sensor Range(MΩ cm) 1.0~20.0MΩ cm 1.0~20.0MΩ cm Electrode Material SS 316L SS 316L Temperature Sensor NTC 30K NTC 30K Cell Constant 0.05 cm cm -1 Process Connection 1/2" NPT 1/2" NPT Insertion length 90 mm 90 mm Cable length 10 m 20 m Accessory Sensor Connection 8-TF021 1/2 NPT bypass chamber Ø12.7mm 0.5" 1/2" NPT Bypass chamber 90mm 5.54" 150mm 5.91" 8-11 Series 29
30 Accessories D.O. Transmitter Accessories D.O. Sensor 690 D.O. Sensor, with 7m cable 620 Replacing membrane kit for D.O. Sensor (2pc) Sensor Protection Holder DO DO-100 Protective Electrode Holder for DO sensor, 1M, Incl. waterproof cap Protective Electrode Holder for DO sensor, 1M, Incl. Junction Box Protection holder s Accessory Plastic L Shaped Electrode Holder Support Base 00416A Stainless L Shaped Electrode Holder Support Base (Designed for immersing in a running basin) 8-SF01 Protection holder float for measurement in variable water levels or in lakes, etc. 8-CH-20 D.O. sensor head auto clean kit Extension cable for sensor F94008-G Extension cable for 690 D.O. sensor (per meter) Sun shield Sun Shield with Pipe Mounting kit Sun Shield with Wall Mounting kit DO D.O. Sensor 8-CH-20 D.O. auto-clean kit Residual Chlorine Transmitter Accessories Residual Chlorine Sensor Residual Chlorine Sensor, (4P, 0-20ppm, operating range ph5.5~8.0) Cable for Residual Chlorine Sensor, (10m) 8-TF-04 Flow through chamber for Chlorine Sensor Sun shield Sun Shield with Pipe Mounting kit Sun Shield with Wall Mounting kit 8-SF01 Chlorine sensor 30
31 Accessories Turbidity/Suspended Solids Transmitter Accessories Turbidity/Suspended Solids Sensor TC-100 TC-500 TC ~100 NTU Turbidity Sensor, 0 ~ 40 C, cable length 10m, Immersion in open tanks 0~500 NTU Turbidity Sensor, 0 ~ 40 C, cable length 10m, Immersion in open tanks 0~3000 NTU Turbidity Sensor, 0 ~ 40 C, cable length 10m, Immersion in open tanks 0~1000 ppm Suspended Solids sensor, 0 ~ 40 C, cable length TCS m, Immersion in open tanks Sensor Protection Holder DO-100 Protective Electrode Holder for Turbidity/S.S. sensor, 1M, Incl. waterproof cap, sensor mounting kit Protection holder s Accessory 00416A Stainless L Shaped Electrode Holder Support Base 8-SF01 Protection holder float for measurement in variable water levels or in lakes, etc. Standard solutions Standard solution 1000 NTU, 500c.c Standard solution 4000 NTU, 500c.c. Sun shield Sun Shield for TC-7100 with Pipe Mounting kit Sun Shield for TC-7100 with Wall Mounting kit Turbidity/S.S. Sensor Wall mounted Sun Shield Ion Transmitter Accessories F - Ion Sensor F - ISE combinated electrode (measuring free F - ion in solutions) with ATC, 5m cable, range: 0.20~20000ppm F - Process_F Limitation: ph 5~10, conductivity: min. 500 μs/cm, flow rate: 1~20cm/s, Temp.: 0~50 C Sensor Protection Holder Protective Electrode Holder for F - sensor, 1M, PP-100F Incl. Waterproof cap Protective Electrode Holder for F - sensor, 1M, PP-100F Incl. Junction box (when combined with extension cable) Protection holder s Accessory F94009-BK Extension cable for F - ION sensor (per meter) Stainless L Shaped Electrode Holder Support Base (Designed for 00416A immersing in a running basin) Protection holder float for measurement in variable water levels 8-SF01 or in lakes, etc. Standard solution F - ion standard solution 1000ppm, 475 ml Pipe mounted Sun Shield 31
32 13F., No.31, Lane 169, Kangning St., Xizhi Dist., New Taipei City 22180, Taiwan Tel: Fax: C Online /Technical data subject to alternations / Quality Systems ISO 9001
About Suntex. Online Measurement and Control. Portable and Laboratory Instruments
About Suntex Suntex Instruments Co., Ltd. established in 1982 in Taiwan, has gained prestige and trust from our customers for dedication of providing professional, high-quality water analysis products
More informationHow to build a Conductivity Measurement System
How to build a Measurement System F B E C D A A Immersion system in open basin B Flow-through system C 1/2 pipe mounted system D 3/4 pipe mounted system E Side-entry system in vessel F Top-entry system
More informationIntelligent SUNTEX EC4110(RS) Conductivity Transmitter
Cond.. Res. C Intelligent SUNTEX EC4110(RS) Conductivity Transmitter Principle Conductivity, which is highly dependent on the amount of dissolved salts, is a measurement of the level of ion concentration
More informationMultiparameter Waterproof Meters. Multiparameter measurement in compact, IP67 rated waterproof enclosures
Multiparameter Waterproof Meters Multiparameter measurement in compact, IP67 rated waterproof enclosures HI98194 Features HI98194 Multiparameter Waterproof Meter ph, ORP, EC, TDS, Resistivity, Salinity,
More informationIndustrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4
Product Selection Guide Industrial Analyzers 1 Controllers 2 Transmitters 3 Monitors 4 Laboratory and Field Benchtop Meters 5 Field Meters 5 Benchtop Controllers 7 Pocket Meters & Testers 9 Accessories
More informationMultiparameter Waterproof Meters. Multiparameter measurement in compact, IP67 rated waterproof enclosures
Multiparameter Waterproof Meters Multiparameter measurement in compact, IP67 rated waterproof enclosures HI98195 Features HI98195 Multiparameter Waterproof Meter ph, ORP, EC, TDS, Resistivity, Salinity,
More informationProfessional Waterproof Meters. ph, ph/ise, EC/TDS and DO
Professional Waterproof Meters ph, ph/ise, EC/TDS and DO HI9819X Series Professional Waterproof Meters New Quick Connect Probes (HI98190, HI98192 and HI98193 only) Benchtop Performance in a Portable Meter
More informationHI 9828 Multiparameter Water Quality Meter...
HI 9828 Multiparameter Water Quality Meter... Backlit LCD can display up to 12 Measurements at a time Feature Highlights Display up to 12 parameters Graphic LCD with backlight Meter features IP67 and probe
More informationHanna Instruments HI9819X Multiparameter series
Hanna Instruments HI9819X series www.hannainst.com HI98194 Waterproof Meter ph / mv, ORP, EC, TDS, Resistivity, Salinity, Seawater σ, Dissolved Oxygen, Atmospheric Pressure and Waterproof IP67 rated waterproof,
More informationHandheld Water Quality Meters 100 Series
ph ORP Ion Conductivity Resistivity TDS DO Salinity Handheld Water Quality Meters 100 Series METERS 2 YEAR W A R R A N T Y M A D E I N J A P A N www.horiba-laqua.com In the lab, in the field or anywhere
More informationHandheld Water Quality Meters 100 Series
ph ORP Ion Conductivity Resistivity TDS DO Salinity Handheld Water Quality Meters 100 Series METERS 2 YEAR W A R R A N T Y M A D E I N J A P A N www.horiba-laqua.com In the lab, in the field or anywhere
More informationProfessional waterproof meters. ph, ph/ise, EC/TDS and DO
Professional waterproof meters ph, ph/ise, EC/TDS and DO HI9819X series Professional waterproof meters New quick connect probes (HI98190, HI98192 and HI98193 only) Benchtop performance in a portable meter
More informationHI 9828 Multiparameter Water Quality Meter...
HI 9828 Multiparameter Water Quality Meter... Backlit LCD can display up to 12 Measurements at a time Feature Highlights Display up to 12 parameters Graphic LCD with backlight Meter features IP67 and probe
More informationMicroprocessor SUNTEX EC-410/430. Conductivity Monitor
Microprocessor SUNTEX EC-410/430 Conductivity Monitor EC-410 μs/cm ms/cm MΩ cm 4-20mA Output ISOLATED 4-20mA OUTPUT Accurate measurement and signal transmission.. EC-430 Microprocessor Conductivity Monitor
More informationCX3100 Intelligent Conductivity Transmitter
CX3100 Intelligent Conductivity Transmitter Operation Manual CX3100 CONTENTS Precautions for Installation Brief Instruction 1 1. Specifications 4 2. Assembly and Installation 2.1 Transmitter Installation
More informationELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:
BOECO PORTABLE PH/ORP/TEMP METER MODEL PT-380 A Simultaneous displays ph or mv and temperature. A Convenient calibration with automatic buffer recognition of European and US buffer sets. Calibration data
More informationProfessional Waterproof Meters
HI9819X Series Professional Waterproof Meters New Quick Connect Probes (HI98190, HI98192 and HI98193 only) Benchtop Performance in a Portable Meter The HI9819X series of meters combine all of the features
More informationBenchtop Multi-parameter Water Quality Meter
LMPWM-A Series Benchtop multi-parameter water quality meter LMPWM-A series is comes with different measurement modes for quality and testing of water on different parameters. It measures ph, Conductivity,
More informationResearch Grade Meters. ph, ISE, EC and DO. Laboratory bench meters with a color, graphic display and capacitive touch keypad
Research Grade Meters ph, ISE, EC and DO Laboratory bench meters with a color, graphic display and capacitive touch keypad HI5000 Series Research Grade Meters Overview HI5000 Series Research Grade Meters
More informationSolutions to the Most Challenging Environments
Solutions to the Most Challenging Environments Short Catalog Feb, 2017 AM-2300 Multi-Input, Multi-Parameter Controller Inputs for four 4-20 ma sensors of any kind in any combination: ph, ORP, conductivity,
More informationph and Electrochemistry
Portable Meters Portable Meters At-a-Glance Selection Guide Take your measurements into the great outdoors. Our Orion Star A series portable meters are built rugged and waterproof for dependable performance.
More informationProfiLine Handhelds. For ph, ISE, Dissolved Oxygen and Conductivity
ProfiLine Handhelds For ph, ISE, Dissolved Oxygen and Conductivity ProfiLine Single Parameter Instruments Data-logging Ground Water Wastewater Surface waters Quality Fishfarming 3110 Series and 3205 :
More informationPlug & Play Analytical Solutions Making Basic Measurements Easy
easy Line easy Line Plug & Play analytics Complete solution package Easy commissioning & installation Plug & Play Analytical Solutions Making Basic Measurements Easy easy Line A Complete Solution Package
More information200CRS Single-Channel Conductivity/Resistivity Measurement System THORNTON. Leading Pure Water Analytics
THORNTON Leading Pure Water Analytics - NIST Traceable Calibration - Two Analog Outputs Standard - Three-Wire Temperature Measurement - Wide Range of Sensor and Cable Selections 200CRS Single-Channel Conductivity/Resistivity
More informationProfiLine Single Parameter Instruments Data-logging Communication Ground Water Wastewater Mobile Lab Measurements Surface waters Measurements Communic
ProfiLine Handhelds For ph, ISE, Dissolved Oxygen and Conductivity ProfiLine Single Parameter Instruments Data-logging Communication Ground Water Wastewater Mobile Lab Measurements Surface waters Measurements
More information200 Series Handheld Water Quality Meters
200 Series Handheld Water Quality Meters ph ORP Dissolved Oxygen Conductivity Resistivity Total Dissolved Solids Salinity METERS 3 YEARS W A R R A N T Y MADE IN JAPAN www.horiba-laqua.com 200 Series Handheld
More informationportable waterproof multiparameter meter
water resistant battery powered interchangeable electrode DIN connection replaceable electrode portable waterproof multiparameter meter Professional testing and analysis out in the field is supported by
More informationVersatile Transmitter Series For Intelligent Measurement Solutions. INGOLD Leading Process Analytics
INGOLD Leading Process Analytics Transmitter Series M400 / M420 / M300 Transmitters Extended ISM functions Easy handling Intuitive user interface Multi-parameter Versatile Transmitter Series For Intelligent
More informationHandheld Water Quality Meters 100 Series
ph ORP Ion Conductivity Resistivity TDS DO Salinity Handheld Water Quality Meters 100 Series METERS 2 YEAR W A R R A N T Y M A D E I N J A P A N www.horiba-laqua.com In the lab, in the field or anywhere
More informationSignet 9900 Transmitter
Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Panel Mount Field Mount NEW! Modbus Module supports RS485 Serial Modbus Communications Multiple sensor types supported with
More informationTransmitter Series M400 / M300 transmitters Extended ISM functions Easy handling Intuitive user interface Multi-parameter
INGOLD Leading Process Analytics Transmitter Series M400 / M300 transmitters Extended ISM functions Easy handling Intuitive user interface Multi-parameter Versatile Transmitter Series For Intelligent Measurement
More informationResearch Grade Meters. ph, ISE, EC and DO. Laboratory bench meters with a color, graphic display and capacitive touch keypad
Research Grade Meters ph, ISE, EC and DO Laboratory bench meters with a color, graphic display and capacitive touch keypad HI5000 Series Research Grade Meters Overview HI5000 Series Research Grade Meters
More informationElectrochemistry Meters. Series SD (IP 67 waterproof) Electrochemistry Meters
Electrochemistry Meters Series SD (IP 67 waterproof) 82 The new AQUALYTIC SD series comprises a range of compact, easy-to-use, hand-held instruments for the accurate measurement of ph, ORP, Con, TDS or
More informationLAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER
LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER The Model 1575e uses the latest in microprocessor capability, giving the user a high level of application flexibility. A large illuminated graphics
More informationMicroprocessor ph/orp Controller
PC3030A/PC-3050 Microprocessor ph/orp Controller Operating Manual CONTENTS 1 Specifications... 2 Assembly and installation... 2.1 Precautions for installation.. 2.2 Install the controller on the wall mount
More informationQuality Electrochemical Analysis Professional Meters Basic Meters Sensors
Quality Electrochemical Analysis Professional Meters Basic Meters Sensors Sartorius Electrochemistry: ph Conductivity DO Meters Quality and Convenience Sartorius approach is to offer a complete range of
More informationMicroprocessor Resistivity & Conductivity Monitor/Controller EC410 / EC430. Operation Manual
Microprocessor Resistivity & Conductivity Monitor/Controller EC410 / EC430 Operation Manual INDEX 1 Specifications 2 Assembly and installation 2.1 Precautions for installation 2.2 Installation of controller
More informationSignet Conductivity Electrodes
Signet 2839-2842 Conductivity Electrodes Features ± 1% accuracy - Custom calibration certificate provided Dual-threaded Compact electrode length for easy in-line installation in small pipe sizes Triple
More informationResearch Grade Meters
HI5521 HI5522 Research Grade Meters ph/orp/ise and EC/TDS/Resistivity/Salinity and Temperature bench Conductivity/TDS Measure up to Eight Parameters HI5521 and HI5522 are research grade benchtop instruments
More informationThermo Scientific AquaPro Multi-Input Intelligent Process Analyzer
Thermo Scientific AquaPro Multi-Input Intelligent Process Analyzer Thermo Scientific AquaPro provides accurate, user-friendly in-line monitoring of process applications from power generation to municipal
More informationQuality Electrochemical Analysis Professional Meters Basic Meters Sensors
Quality Electrochemical Analysis Professional Meters Basic Meters Sensors Sartorius Electrochemistry: ph Conductivity DO Meters Quality and Convenience Sartorius approach is to offer a complete range of
More informationWK7200. Water Quality Test Kit USER S MANUAL
WK7200 USER S MANUAL Water Quality Test Kit INTRODUCTION: Thank you for selecting model WK7200 microprocessor-based waterproof Water Quality Test Kit. It is used to measure a wide range of ph, ORP, Conductivity,
More informationFiveGo. FiveGo Portable Instruments ph mv / ORP Conductivity TDS Dissolved Oxygen. Simplify Your Mobile Lab Quality Measurement for the Budget Minded
FiveGo FiveGo Portable Instruments ph mv / ORP Conductivity TDS Dissolved Oxygen Simplify Your Mobile Lab Quality Measurement for the Budget Minded Introducing the FiveGo TM Series Keeping ph Measurements
More informationfor measuring ph values and redox potential, conductivity and dissolved oxygen Content
for measuring ph values and redox potential, conductivity and dissolved oxygen Content Portable ph meters with GLP functions handylab ph 11 and handylab ph 12 Page 32 Technical data handylab LF 11, handylab
More informationResolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F
RMS Rainwater Harvesting Series 100 Controller Specifications Measurement Performance Contacting Conductivity ph Range 0-10,000 µs/cm Range -2 to 16 ph units Resolution 1 µs/cm Resolution 0.01 ph units
More informationSingle Parameter Meters Lightweight and versatile ph, EC and DO meters that can be used in portable, wall-mount and benchtop configurations
Single Parameter Meters Lightweight and versatile ph, EC and DO meters that can be used in portable, wall-mount and benchtop configurations Digital electrodes edge performs measurements through its unique
More informationConductivity Transmitters
Conductivity Transmitters CDTX-90 Series Starts at $ 576 Electronics Only Display in µs, ms, kω, MΩ, ppm (TDS) Simulate Function Programmable Temperature Compensation Relay Options Dual Output Option Allows
More informationGPS Multiparameter Meters
HI9829 GPS Meters ph/orp/ise, EC/TDS/ Resistivity/Salinity/Seawater, Turbidity, DO, Temperature and Atmospheric Pressure Logging Logging from probe or meter Fast Tracker Tag Identification System Sensor
More informationProLab 1. ProLab 1000: ph for the professional. ph Meter ProLab 1000: Superior technique in a classy metal body. Precise measurements
ProLab 1000: ph for the professional ProLab 1000: Superior technique in a classy metal body Precise measurements With a measuring range of -2.000 up to +20.000 ph and an accuracy of 0.003 ph the ProLab
More informationRange. Body Material. Max. Press ms K=0, C 4 bar Glass Graphite 13.5 PG Full integrated 5-meter cable
Conductivity Range Conductivity 0 20 μs; 0 200 μs; 0 2.000 μs; 0 20.000 μs; 0 200.000 μs Resolution 0,01 μs; 0,1 μs; 1 μs; μs Avaiable versions with double parameter 4238-22 [ph/orp - Conductivity] 4293-22
More informationMXD70 SERIES. Instrumentation to meet your Process Requirements. Features.
MXD70 SERIES Instrumentation to meet your Process Requirements Features The innovative MXD70 series of process instruments brings a new dimension to analytical process measurements with the modular design
More informationWaterproof Tester ph - mv - Conductivity - TDS - Salinity - Temperature
2 Waterproof Tester ph - mv - Conductivity - TDS - Salinity - Temperature makes ph and conductivity easy Applications: Agriculture - treatment of waters and wastewaters - hydroponic crops and aquariums
More informationDouble-channel measuring and control instrument for free chlorine and ph-value - additionaly ORP optional
Double measurement of free chlorine and ph -optionally with additional ORP measurement Easy and safe operation by plain text menu guidance Log book function Graphical trend display of the last 3 h applications
More informationNeon pr. ph/ ORP measurement. Applications. Description
Easy handling by graphical menue Fitting for your application by modular setup Simple firmware update and configuration using SD-card Applications Process Water Drinking Water / Beverages Waste Water Treatment
More informationIntroduction: Features:
Index Features:... 3 Specifications:... 4 Accessories:... 5 Functions of Keyboard:... 7 Preparation:... 8 ... 8 ... 8 Calibration:... 8 ... 8 ... 9 ...
More informationHQd DIGITAL METERS. A customized solution for water quality testing that takes the guesswork out of your measurements. Easy to Use in the Field
HQd DIGITAL METERS & IntelliCAL PROBES A customized solution for water quality testing that takes the guesswork out of your measurements. Easy to Use in the Field The wide variety of rugged probe options
More informationWaterproof Construction. Notepad Function. Automatic Datalogging. Automatic Calibration. Good Laboratory Practices. Serial Interface Port
Waterproof Construction At TPS we know that working in wet areas is sometimes unavoidable. The 90 series is designed for rugged field applications in wet environments. The enclosure, keypad and connectors
More informationOperation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter
Operation Manual MODEL 2TX 2-wire Isolated ph/orp Transmitter 0 2TX CONTENTS INITIAL INSPECTION.....2 INTRODUCTION......2 ASSEMBLY...3 PREPARATION....4 CONNECTING THE ELECTRODE...4 CONNECTING THE TEMPERATURE
More informationUser's Guide. Online Meters. PH / ORP / TDS / Conductivity.
User's Guide Online Meters PH / ORP / TDS / Conductivity www.rakiro.net Introduction Continuous monitoring of PH / ORP is commonly required in a wide variety of industries ranging from water, chemical,
More informationEC-4310 Intelligent Conductivity Transmitter. Operation Manual
EC-4310 Intelligent Conductivity Transmitter Operation Manual CONTENTS Precautions for installation Brief Instruction 1 1. Specifications 4 2. Assembly and installation 2.1 Transmitter installation 5 2.2
More informationT80 Universal Transmitter S80 Intelligent Sensors
T80 Universal Transmitter S80 Intelligent Sensors Presented by: January 2012 ELECTRO-CHEMICAL DEVICES T80 Universal Transmitter One Transmitter for Multiple Measurements ph ORP Dissolved Oxygen All Specific
More informationph 8+ DHS ph- mv - Temperature GLP - USB Data Logger - RS232 printer
Bench meters ph 8+ DHS ph- mv - Temperature GLP - USB Data Logger - RS232 printer ph 80+ DHS ph - mv - ION - Temperature GLP - GMP - USB Data Logger - RS232 printer DHS Digital High Sensor Intelligent
More informationProcess Analysis Systems. Stratos Pro A4 MSPH/MSPH. Chem Energy Pharm Food Water. Connection
Process Analysis Systems Chem Energy Pharm Food Water Stratos Pro A4 MSPH/MSPH Connection Connection of Memosens interface of 4-wire device with 2 Memosens sensors Model used: Stratos Pro A401N MSPH/MSPH
More informationMemoRail. Compact. Cost-efficient. Digital. Plug & Measure with the new analyzers for Memosens. ph ORP Cond Oxy Temp.
Compact. Cost-efficient. Digital. Plug & Measure with the new analyzers for Memosens ph ORP Cond Oxy Temp The Essence of Measuring is the first genuinely compact, digital analyzer for measuring ph values,
More informationFiveGo. FiveGo Portable Instruments ph mv / ORP Conductivity TDS Dissolved Oxygen. Simplify Your Mobile Lab Quality Measurement for the Budget Minded
FiveGo FiveGo Portable Instruments ph mv / ORP Conductivity TDS Dissolved Oxygen Simplify Your Mobile Lab Quality Measurement for the Budget Minded Introducing the FiveGo TM Series Keeping ph Measurements
More informationWaterproof Testers. ph - mv - ORP - Conductivity - TDS - Salinity - Temperature
Tester 4 Waterproof Testers ph - mv - ORP - Conductivity - TDS - Salinity - Temperature makes ph and conductivity easy Applications: Agriculture - treatment of waters and wastewaters - hydroponic crops
More information703 Laboratory Conductivity Meter
703 Laboratory Conductivity Meter Sensoface Sensoface monitors the sensor and measuring equipment and provides information on sensor selection and handling. It reports clock memory loss and requests regular
More informationFiveGo. FiveGo Portable Instruments ph mv / ORP Conductivity TDS Dissolved Oxygen. Simplify Your Mobile Lab Quality Measurement for the Budget Minded
FiveGo FiveGo Portable Instruments ph mv / ORP Conductivity TDS Dissolved Oxygen Simplify Your Mobile Lab Quality Measurement for the Budget Minded Introducing the FiveGo TM Series Keeping ph Measurements
More informationTransmitter / Controller Series J dtrans ph 01, Rd 01, Lf 01, Rw 01, Az 01
Transmitter / Controller Series J dtrans ph 01, Rd 01, Lf 01, Rw 01, Az 01 with C-UL-US approval PR 20004 GB ph mv ms/cm µs/cm M xcm Transmitter / Controller Series J dtrans ph 01, Rd 01, Lf 01, Rw 01,
More informationThermo Scientific Orion Star A214 ph/ise Benchtop Meter
Orion Star A Meters Keep turning the pages for more great finds. Thermo Scientific Orion Star A214 / Benchtop Meter The Thermo Scientific Orion Star A214 / Benchtop Meter is the ideal choice for dedicated
More informationMMT330 Series Moisture and Temperature Transmitters for Oil
MMT330 Series Moisture and Temperature Transmitters for Oil Features Continuous online measurement of moisture in oil Ball-valve installation no need to shut down the process or drain the oil Proven Vaisala
More informationOPERATION MANUAL MODEL TT-LP
TURTLE TOUGH OPERATION MANUAL MODEL TT-LP 2-Wire Isolated ph/orp Transmitter turtletough.com.au CONTENT INITIAL INSPECTION 3 INTRODUCTION 3 ASSEMBLY 4 PREPARATION 5 Connection Diagram of Turtle Tough Sensors
More informationInstruments and Capabilities (Panel Mount and Standalone) By: Thornton Leading Pure Water Analytics
Instruments and Capabilities (Panel Mount and Standalone) Table of Instrument Models and Capabilities. ph & Dissolved Instrument System Resistivity Conductivity ORP Oxygen Flow 770MAX Multiparameter Analyzer/Transmitter
More informationType Multichannel Transmitter/Controller multicell for Flow and Analytical Sensors
Type 8619 Multichannel Transmitter/Controller multicell for Flow and Analytical Sensors Type 8619 Product Features and Resulting Advantages multicell Modular multivariable remote transmitter/controller
More informationWTW Multi 340i/3400i Portable Meters
WTW Multi 340i/3400i Portable Meters The rugged, versatile Multimeter This waterproof (IP 66) instrument with battery or optional line adaptor also meets the requirements of IP 67 and is optimally suited
More informationPortavo 904 X Multi. Multiparameter Ex
Multiparameter Ex Portavo 904 X Multi The world's only portable device for liquid analysis with ATEX approval for measurements up to zone 0/1. Ideal for applications in the process industry. For the first
More informationinolab 7000 Series Accurate. Compliant. Sensitive. The inolab family: Advanced measuring technology offers new functions including automatic AutoRead
inolab 7000 Series MEASUREMENT OF ph, ISE, CONDUCTIVITY AND DISSOLVED OXYGEN ACCURATE, COMPLIANT AND SENSITIVE inolab 7000 Series Accurate. Compliant. Sensitive. The inolab family: Advanced measuring technology
More informationControl and automatic dosing
Control and automatic dosing For public and residential pools Control Basic and Control Basic Plus Control Basic Next Optima and Optima Next dosing pumps Panels for the galvanic and amperometric control
More informationAs a result, our corporate philosophy is focused on total customer satisfaction. The Headquarter of Adwa Instruments is located in Szeged, Hungary:
Adwa Instruments Founded in 1998, Adwa Instruments is one of the leading manufacturers of instrumentation to measure, Conductivity, ORP, Dissolved Oxygen and erature for Research and Industry. Headquartered
More information+GF+ SIGNET Conductivity/Resistivity Transmitter Instructions
GF SIGNET 8850 Conductivity/Resistivity Transmitter Instructions ENGLISH 8850.090 A9/99 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to
More informationCX2000 Intelligent Conductivity Transmitter
CX2000 Intelligent Conductivity Transmitter Operation Manual Lin 10.00mS/cm MTC PM 12:00 2013/04/10 25.0 C ACT B.L. SETUP CAL MODE ENTER Conductivity Transmitter CX2000 S/N: 123456789 1 ISO 9001-2008 Cercate
More informationThe Model 703 offers a wide range of practical features to meet the numerous requirements of everyday measuring tasks.
Laboratory Meters The requirements for lab measurements become stricter every day. Quality assurance and measurement documentation in accordance with GLP are a must in many areas. 703 Laboratory Conductivity
More information*suitable both for membrane sensors or chlorine open cell
CTRL POOL THE SIMPLE, RELIABLE, COST EFFECTIVE SYSTEMS FOR SMALL POOLS CTRL POOL is a compact system, with single or dual controller and peristaltic dispensers all in one enclosure. CTRL POOL is extremely
More informationSmart Conductivity. Reliable and Accurate Conductivity/Resistivity Measurement. THORNTON Leading Pure Water Analytics
Smart Conductivity THORNTON Leading Pure Water Analytics 770MAX Conductivity/ Resistivity Sensors ASTM & NIST Traceable Calibration Smart Sensor Technology Two & Four Electrode Designs NPT & Tri-Clamp
More informationControllers. Water Treatment
Water Treatment Controllers Walchem integrates its advanced sensing, instrumentation, fluid handling and communications technologies to deliver reliable and innovation solutions to the global water treatment
More informationResolution selectable from 0.01 and ph. Range ph. Accuracy ± ph
ph Resolution selectable from 0.01 and 0.001 ph Range -2.000 16.000 ph Accuracy ± 0.002 ph Data logging Manual log on demand manual log on stability Interval logging Temperature readout ( C or F) Automatic
More informationField-Lab Analysers for ph, mv, Conductivity, TDS, Salinity, Dissolved Oxygen, Turbidity & Temperature
[Add this page to the Navigation view to display hyperlinks here] [Add this page to the navigation structure to display a page banner here] TPS Australia - Quality instruments since 1968. Field-Lab Analysers
More informationResolution selectable from 0.01 and ph. Range to ph. Accuracy ± ph
ph EC DO ph Resolution selectable from 0.01 and 0.001 ph Range -2.000 to 16.000 ph Accuracy ± 0.002 ph Data logging Manual log on demand Manual log on stability Interval logging Temperature readout ( C
More informationBXD17 Series. Features. Analytical instrumentation for your measurement applications.
BXD17 Series Analytical instrumentation for your measurement applications. Features Single parameter instrument with temperature measurement capabilities Custom IP66 NEMA 4X (144 x 144mm) enclosure Versatile
More informationThe Art of Measuring. Compact. Cost-efficient. Digital. Plug & Measure with the new analyzers for Memosens. MemoRail
The Art of Measuring. Compact. Cost-efficient. Digital. Plug & Measure with the new analyzers for Memosens The Essence of Measuring is the first genuinely compact, digital analyzer for measuring ph values,
More informationHQd Digital Meters and IntelliCAL Probes
DATA SHEET HQd Digital Meters and IntelliCAL Probes Electrochemistry HQd Digital Meters Guided Calibrations All Hach HQd Digital Meters provide an intuitive user interface with guided calibration and check
More informationElectrodes ph EC DO /14 dge 2 P/L e
ph EC DO ph Resolution selectable from 0.01 and 0.001 ph Range -2.000 16.000 ph Accuracy ± 0.002 ph Data logging Manual log on demand Manual log on stability Interval logging Temperature readout ( C or
More informationOperation Manual. Hand-held Conductivity/Salinity/TDS/ Temperature Meter 3010M
Operation Manual Hand-held Conductivity/Salinity/TDS/ Temperature Meter 3010M CONTENTS GENERAL INTRODUCTION...2 INITIAL INSPECTION......2 WATER PROOF.......2 INSTALLING THE BATTERIES.....3 DISPLAY & KEYS
More information770MAX Conductivity/Resistivity Sensors THORNTON. Leading Pure Water Analytics
THORNTON Leading Pure Water Analytics - ASTM & NIST Traceable Calibration - Smart Sensor Technology - Two & Four Electrode Designs - NPT & Tri-Clamp Connections 770MAX Conductivity/Resistivity Sensors
More informationOperation Manual. MODEL ph6175. Microcomputer Based ph/orp/temperature Benchtop Meter
Operation Manual MODEL ph6175 Microcomputer Based ph/orp/temperature Benchtop Meter ph6175 0 CONTENTS GENERAL INTRODUCTION...2 INITIAL INSPECTION......2 POWER INPUT.......2 INSTALLING THE BATTERIES.....3
More informationEndress Hauser CUM 740. Measuring Transmitter for Turbidity and Solids Content ISO The Power of Know How
Technical Information TI 232C/07/en 51504297 Measuring Transmitter for Turbidity and Solids Content The transmitter is used for optical solid matter content measurement in clear and turbid water and in
More informationThe Art of Measuring. Compact Transmitter with Modbus Interface. MemoRail Modbus
The Art of Measuring. Compact Transmitter with Modbus Interface MemoRail Modbus MEMO SENS MemoRail Modbus A 1405 N Compact and Inexpensive. MemoRail Modbus is a space-saving transmitter with Modbus RTU
More informationsc200 UNIVERSAL CONTROLLER Applications
sc200 UNIVERSAL CONTROLLER Applications Drinking Water Wastewater Industrial Water Power One Controller for the Broadest Range of Sensors. Choose from 30 digital and analog sensor families for up to 17
More informationJUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature
Page 1/7 JUMO ecotrans 03 Microprocessor transmitter/ switching device for /Redox voltage and temperature with a 2-line LCD for mounting on a 35 mm DIN rail Brief description Depending on the configuration,
More informationGRUNDFOS ALLDOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers for conductivity measurement 50/60 Hz
GRUNDFOS ALLDOS DATA BOOKLET Measuring amplifiers and controllers for conductivity measurement 50/60 Hz TM042232 if Contents Product features Conex DIS 3 3 Identification Type key,, controller 4 Type key,,
More information