1 Model T28 Transmitter Product Training Presented by: Joe Bradley October 2009 ELECTRO-CHEMICAL DEVICES

2 Model T28 Transmitter Two Wire Transmitter Loop Powered Ω Measurement Choices ph ORP Specific Ion Dissolved Oxygen Conductivity Resistivity Displays Measured Parameter and engineering Units Percent Output (4-20 ma) Temperature C or F

3 Model T28 Transmitter FM and CSA approved Transmitter Explosion Proof FM and CSA Class I, Division I, Groups C G Intrinsically Safe FM Approved Class I, II, III, Division I, Groups A G 300 series Stainless Steel NEMA 7C

4 Model T28 Transmitter Calibrate and Configure Through the Lens Glass ECD Magnetic Screwdriver Never Need To Open the Instrument Magnetically Activated Keys Hall Effect switches The presence of a Magnetic Field causes electrons in the Hall Element to deflect creating a voltage. Click

5 Model T28 Transmitter Modular design Precision Machined from 300 series Stainless Steel Electronics Module mechanically Isolated from Wiring Electronic Modules are Easily Removed Screw off the Front Cover, Unplug the Module, No Tools needed

6 Model T28 Transmitter Covers are easily Removed Display can be rotated ± 90 to accommodate a variety of Installation and Viewing angles Rear Cap contains Wiring diagram Electronics modules are interchangeable Remove/Replace the modules for Diagnostic Maintenance or Calibration in the shop

7 T28 Navigation Vertical Adjustment Keys are Above the Display UP Key on the Left Hand Side DOWN Key on the Right Hand Side Vertical Adjustment Keys Scroll UP or DOWN Through Screens Increase or Decrease Numeric Values

8 T28 Navigation Horizontal Adjustment Keys are Below the Display Left Horizontal Key Right Horizontal Key Horizontal Adjustment Keys Move the Cursor Left or Right Enter a Menu Line with the Right Horizontal Key Exit a Menu Line and Save the entry with the Left Horizontal Key. Activate the multiple times until the cursor has moved all the way to the left.

9 T28 Start Up Screen Power Up the T28 24 VDC at 500 ohms Minimum 14 VDC Maximum 50 VDC Start Up Screen appears for 30 Seconds Serial Number: 1068 Software Version: 2.26 Copyright ECD 2009 Automatically switches to the HOME SCREEN upon completion of Start Up Diagnostics

10 T28 HOME SCREENS HOME SCREEN Measured Parameter, Eng. Units % 4-20 ma Output Temperature, C or F Measured Parameters Resistivity, RS, M (Meg Ohms) ph Dissolved Oxygen, DO, ppm ORP, (mv) Specific Ion, ppm Conductivity, ms, us

11 T28 ph Manual Mode Before Starting a Calibration put the Transmitter in Manual Mode 4-20 ma Output HOLD Function Enter Manual Mode Magnetically activate the Right Horizontal Arrow key An M will appear in front of the % Output The T28 output is now under manual control Exit Manual Mode Magnetically Activate the Left Horizontal Arrow Key Move to the Diagnostic Screen Magnetically Activate the Down Arrow Key

12 T28 ph Diagnostic Screen Diagnostic Screen Raw mv input from the ph sensor Zero Point from Last Calibration No Cursor, therefore No Entry, Information Only Move to the Calibration Screens Magnetically Activate the Down Arrow Key

13 T28 ph Calibration, Zero Point The 1 ph Screen allows Zero Point Calibration (ph 7) or Standardization to Grab sample Place the sensor in ph 7 buffer Start the Calibration Magnetically Activate the Right Horizontal Key If ph 7 is not displayed use the Key to move the cursor to the insertion point and use the or to adjust the value. Accept the Calibration when the mv reading has stabilized Magnetically Activate the Left Horizontal Arrow Key Each Activation moves the Cursor one slot to the Left When the Cal line reappears the Calibration has been Saved

14 T28 ph Calibration, Standardize Start a Standardization Magnetically Activate the Right Horizontal Key Adjust the ph value to agree with a Grab Sample Use the Key to move the cursor to the insertion point use the to adjust the value Largest Digit first Accept the Calibration when the mv reading has stabilized Magnetically Activate the Left Horizontal Arrow Key Each Activation moves the Cursor one slot to the Left When the Cal line reappears the Calibration has been Saved Scroll down to the Cal Line by Activating the Key

15 T28 ph Calibration Cal is the mv offset in ph 7 buffer Most ph sensors are designed to read 0 mv in ph 7. If the Cal value is greater than 60 mv replace the electrode The Cal value is the actual mv reading, ignore the 60 mv replacement note above if a solution other than ph 7 is used To reset the Cal value to the factory default, 0 mv Use the key to enter a line Scroll down to the 2 ph Screen

16 T28 ph Calibration, Slope The 2 ph Screen is the Slope Calibration Screen, mv/dec Place the sensor in ph 4.01 buffer ph 4.0 recommended but any solution greater than 2 ph units away from the Zero point calibration value can be used Start the Calibration Magnetically Activate the Right Horizontal Key If ph 4 is not displayed use the Key to move the cursor to the insertion point and use the or to adjust the value. Accept the Calibration when the mv/dec reading has stabilized Magnetically Activate the Left Horizontal Arrow Key Each Activation moves the Cursor one slot to the Left When the Cal line reappears the Calibration has been Saved

17 T28 ph Calibration, Slope Cal is the mv/ph Slope Most ph sensors are designed to read 59 mv/decade of change Calculated from the two Calibrations, 1 ph and 2 ph Values below 50 mv/dec indicate the sensor needs cleaning or replacement To reset the Cal value to the factory default, mv/dec Use the key to enter the Cal line, it automatically resets Scroll down to the Output Screen

18 T28 Output, 4 ma Set Up The default 4-20 ma Output setting is 0-14 ph To Change the 4 ma setting Magnetically activate the Right Horizontal Arrow key Use the Left Horizontal Arrow key to move the Cursor to the digit to be changed Use the Up Arrow key to adjust the value Save the New 4 ma Setting Magnetically Activate the Left Horizontal Arrow Key Each Activation moves the Cursor one slot to the Left When the Cursor has returned to the position _4 the setting has been Saved Scroll down to the 20 ma line using the Down Arrow key

19 T28 Output, 20 ma Set Up To Change the 20 ma setting Magnetically activate the Right Horizontal Arrow key Use the Left Horizontal Arrow key to move the Cursor to the digit to be changed Use the Up Arrow key to adjust the value Save the New 20 ma Setting Magnetically Activate the Left Horizontal Arrow Key Each Activation moves the Cursor one slot to the Left When the Cursor has returned to the position _4 the setting has been Saved Scroll down to the Trim and Units Screen using the Down Arrow key

20 T28 Trim and Units Screen The Trim C Line allows the Temperature Sensor to be Calibrated (trimmed) If the Displayed Temperature of the T28 does not agree with the Known Temperature in the process then Adjust the Trim C Line Magnetically activate the Right Horizontal Arrow key Use the Left Horizontal Arrow key to move the Cursor to the digit to be changed Use the or Arrow keys to adjust the value until the correct Temperature is displayed Save the Change Magnetically Activate the Left Horizontal Arrow Key Scroll down to the Units Line using the

21 T28 Trim and Units Screen The Unit Line allows the display of C or F Magnetically Activating the Right Horizontal Arrow key toggles between C and F There is no entry into the line it just toggles back and forth Return to the HOME Screen Magnetically Activate the Up Arrow Key 9X Exit Manual Mode as described earlier

22 T28 Transmitter Training The T28 Transmitter is Calibrated and Running live. Thank You Continue on to a Calibration Screen addendum for: Dissolved Oxygen Conductivity Electro-Chemical Devices 1681 Kettering Irvine, CA

23 T28 Dissolved Oxygen Calibration The 1DO Screen is the Zero Point Calibration. The Dissolved Oxygen sensor must be in a zero oxygen environment. Start the Calibration Magnetically Activate the Right Horizontal Key Accept the Calibration when the mv reading has stabilized Magnetically Activate the Left Horizontal Arrow Key Each Activation moves the Cursor one slot to the Left When the Cal line reappears the Calibration has been Saved Scroll down to the 2DO Screen using the Down Arrow key

24 T28 Dissolved Oxygen Calibration The 2DO Screen is the Span Calibration Typically an Air Cal (100%) Any known O 2 environment can be used (8.25 ppm) Start the Calibration Magnetically Activate the Right Horizontal Key Enter the DO value Use the Key to move the cursor to the insertion point use the to adjust the value Largest Digit first Accept the Calibration when the mv reading has stabilized Magnetically Activate the Left Horizontal Arrow Key

25 T28 Cond. Calibration (MAX) Scroll down to the MAX Screen MAX is the Measurement Range Typically Sensor Value x 2.5 Set the MAX Value Magnetically Activate the Right Horizontal Key Use the Left Horizontal Arrow key to move the Cursor to the digit to be changed Use the or Arrow keys to adjust the value until the correct value is displayed Save the MAX Magnetically Activate the Left Horizontal Arrow Key When the Cursor is below the M the MAX value has been Saved

26 T28 Cond. Calibration (Pct/ C) Scroll Down to the Pct/ C Line Temperature compensation Most solutions vary % per C Enter and Adjust the Pct/ C (optional) Magnetically Activate the Right Horizontal Key Use the Left Horizontal Arrow key to move the Cursor to the digit to be changed Use the or Arrow keys to adjust the value until the correct value is displayed Use the Left Horizontal Arrow Key to Save the value Scroll up to the Dry Screen using the Up Arrow key (3X)

27 T28 Cond. Calibration (Dry) Dry Cal Sets the Zero Point The Cond. Sensor must be dry and in air Start the Dry Cal Magnetically Activate the Right Horizontal Arrow key An asterisk and diagnostic number will appear The Diagnostic should trend towards 75 When the Asterisk disappears save the calibration Save the Dry Cal Magnetically Activate the Left Horizontal Arrow Key When the Cursor is below the D the Dry value has been Saved Scroll Down to the Buffer Screen using the Down Arrow key

28 T28 Cond. Calibration (Buffer) Buffer Input is the Span Calibration Use a Calibration solution (most accurate) or Resistor value = Cell constant / Conductance Ω = 55/conductivity value in Siemens Enter a Value and Start the Calibration Magnetically Activate the Right Horizontal Key Use the Left Horizontal Arrow key to move the Cursor to the digit to be changed Use the or Arrow keys to adjust the value until the correct value is displayed When the Asterisk disappears save the calibration Save the Calibration Use the Left Horizontal Arrow Key to Save the value

T80 Universal Transmitter S80 Intelligent Sensors

T80 Universal Transmitter S80 Intelligent Sensors T80 Universal Transmitter S80 Intelligent Sensors Presented by: January 2012 ELECTRO-CHEMICAL DEVICES T80 Universal Transmitter One Transmitter for Multiple Measurements ph ORP Dissolved Oxygen All Specific

More information

Description, continued

Description, continued DL424/425 DirectLine Sensor Module for DL5000 Dissolved Oxygen Probes Overview 70-82-03-48 4/02 Page of 8 Specification The DirectLine DL424/425 Sensor Modules are part of a family of products developed

More information

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4 Product Selection Guide Industrial Analyzers 1 Controllers 2 Transmitters 3 Monitors 4 Laboratory and Field Benchtop Meters 5 Field Meters 5 Benchtop Controllers 7 Pocket Meters & Testers 9 Accessories

More information

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK Instruction Sheet PN 51A-54epH/rev J October 2010 ph/orp HART Model 54e ph/orp Analyzer/Controller For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. ESSENTIAL

More information

INSTRUCTION MANUAL MODEL T80 UNIVERSAL TRANSMITTER T80 IMC13

INSTRUCTION MANUAL MODEL T80 UNIVERSAL TRANSMITTER T80 IMC13 INSTRUCTION MANUAL MODEL T80 UNIVERSAL TRANSMITTER T80 IMC13 SCREEN MAP CAL (Calibration) CONFIG (Configuration) INFO (Information) SIM (Simulate) Auto Cal 1 (Offset) using Calibration Solution Cal 2 (Slope)

More information

Thermo Scientific Orion Star A329 Portable ph/ise/conductivity/rdo/do Meter. Instruction Sheet

Thermo Scientific Orion Star A329 Portable ph/ise/conductivity/rdo/do Meter. Instruction Sheet English ph / ISE / COND / RDO / DO Thermo Scientific Orion Star A329 Portable ph/ise/conductivity/rdo/do Meter Instruction Sheet Preparation Power Source 1. Power adapter (sold separately) a. Select the

More information

Signet ph/orp Transmitter * *

Signet ph/orp Transmitter * * Loop 7 6 5 Signet 8750- ph/orp *-8750.090-* CAUTION! Contents 0.0 ph 5.0C Signet ph/orp. Installation. Panel Installation gasket panel terminals mounting bracket 96 mm (.8 in.) 8050 8 mm (. in.) Optional

More information

WK7200. Water Quality Test Kit USER S MANUAL

WK7200. Water Quality Test Kit USER S MANUAL WK7200 USER S MANUAL Water Quality Test Kit INTRODUCTION: Thank you for selecting model WK7200 microprocessor-based waterproof Water Quality Test Kit. It is used to measure a wide range of ph, ORP, Conductivity,

More information

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller Operation Manual TX10 1/8 DIN Microcomputer Based /ORP Controller 11751 Markon Drive Garden Grove, CA. 92841 U.S.A. pg. 1 CONTENTS GENERAL INTRODUCTION.....3 INITIAL INSPECTION......3 USING THE Sensorex

More information

MODEL 692P TWO-WIRE ph TRANSMITTER. Manual No. 692P Revision 9-898

MODEL 692P TWO-WIRE ph TRANSMITTER. Manual No. 692P Revision 9-898 MODEL 692P TWO-WIRE ph TRANSMITTER Manual No. 692P Revision 9-898 INSTRUMENT SETUP GUIDE This manual contains detailed instructions for all operating aspects of this instrument. Read Part One for a general

More information

Research Grade Meters

Research Grade Meters HI5521 HI5522 Research Grade Meters ph/orp/ise and EC/TDS/Resistivity/Salinity and Temperature bench Conductivity/TDS Measure up to Eight Parameters HI5521 and HI5522 are research grade benchtop instruments

More information

Introduction: Features:

Introduction: Features: Index Features:... 3 Specifications:... 4 Accessories:... 5 Functions of Keyboard:... 7 Preparation:... 8 ... 8 ... 8 Calibration:... 8 ... 8 ... 9 ...

More information

OPERATION MANUAL MODEL TT-LP

OPERATION MANUAL MODEL TT-LP TURTLE TOUGH OPERATION MANUAL MODEL TT-LP 2-Wire Isolated ph/orp Transmitter turtletough.com.au CONTENT INITIAL INSPECTION 3 INTRODUCTION 3 ASSEMBLY 4 PREPARATION 5 Connection Diagram of Turtle Tough Sensors

More information

Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F

Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F RMS Rainwater Harvesting Series 100 Controller Specifications Measurement Performance Contacting Conductivity ph Range 0-10,000 µs/cm Range -2 to 16 ph units Resolution 1 µs/cm Resolution 0.01 ph units

More information

1. Installation. 2. Configuration - Operation. 3. Specifications. Safety

1. Installation. 2. Configuration - Operation. 3. Specifications. Safety Safety 1. Installation 1.1 OP_ext: Services 1.2 Driver Card Installation 1.3 Sensor Types 1.4 Sensor Wiring 1.5 Controller Wiring 2. Configuration - Operation 2.1 Replaces ph Sensor 2.2 AS -Flex Series

More information

Contents. 1. Installation

Contents. 1. Installation ENGLISH 8750.090 C/0 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents. Installation. Specifications. Electrical

More information

+GF+ SIGNET ph/orp Transmitter Instructions

+GF+ SIGNET ph/orp Transmitter Instructions GF SIGNET 8750 ph/orp Transmitter Instructions ENGLISH 8750.090 A9/99 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury.

More information

Thermo Scientific Orion Star A326 Portable ph/rdo/do Meter. Instruction Sheet

Thermo Scientific Orion Star A326 Portable ph/rdo/do Meter. Instruction Sheet English ph / RDO / DO Thermo Scientific Orion Star A326 Portable ph/rdo/do Meter Instruction Sheet Preparation Power Source 1. Power adapter (sold separately) a. Select the appropriate wall socket plug

More information

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph ph Resolution selectable from 0.01 and 0.001 ph Range -2.000 16.000 ph Accuracy ± 0.002 ph Data logging Manual log on demand manual log on stability Interval logging Temperature readout ( C or F) Automatic

More information

and Multiparameter Meters

and Multiparameter Meters and Multiparameter Meters 54650-23 ph Menu Options Table 1 How to Change ph Menu Options Setup Setup 1 Time Setup 2 Date Setup 3 Year Setup 4 Temperature Units Setup 5 Display Lock Setup 6 Measurement

More information

Research Grade Meters. ph, ISE, EC and DO. Laboratory bench meters with a color, graphic display and capacitive touch keypad

Research Grade Meters. ph, ISE, EC and DO. Laboratory bench meters with a color, graphic display and capacitive touch keypad Research Grade Meters ph, ISE, EC and DO Laboratory bench meters with a color, graphic display and capacitive touch keypad HI5000 Series Research Grade Meters Overview HI5000 Series Research Grade Meters

More information

User Manual. Thermo Scientific Orion Star A320 Series

User Manual. Thermo Scientific Orion Star A320 Series User Manual Thermo Scientific Orion Star A320 Series Electrochemistry Portable Meters 68X000443 Revision A June 2015 Important Note Please read this user guide thoroughly before using your meter. Any use

More information

Thermo Scientific Orion Star A325 Portable ph/conductivity Meter. Instruction Sheet

Thermo Scientific Orion Star A325 Portable ph/conductivity Meter. Instruction Sheet English ph / COND Thermo Scientific Orion Star A325 Portable ph/conductivity Meter Instruction Sheet Preparation Power Source 1. Power adapter (sold separately) a. Select the appropriate wall socket plug

More information

Analyze IT Analytical Instruments Two-Wire ph, ORP, plon Transmitters

Analyze IT Analytical Instruments Two-Wire ph, ORP, plon Transmitters Data Sheet D-NPA-TB82PH_2 Analyze IT Analytical Instruments Two-Wire ph, ORP, plon Transmitters Model TB82PH Series Designed With the Real World in Mind Easy to use menus guide the operator through set-up,

More information

User s Guide PHUTX601. Multi-parameter Transmitter. Shop online at. omega.com For latest product manuals: omegamanual.

User s Guide PHUTX601. Multi-parameter Transmitter. Shop online at. omega.com   For latest product manuals: omegamanual. User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info PHUTX601 Multi-parameter Transmitter OMEGAnet Online Service omega.com Internet e-mail info@omega.com

More information

Thermo Scientific Orion Star A324 Portable ph/ise Meter. Instruction Sheet

Thermo Scientific Orion Star A324 Portable ph/ise Meter. Instruction Sheet English ph / ISE Thermo Scientific Orion Star A324 Portable ph/ise Meter Instruction Sheet Preparation Power Source 1. Power adapter (sold separately) a. Select the appropriate wall socket plug plate.

More information

+GF+ SIGNET Conductivity/Resistivity Transmitter Instructions

+GF+ SIGNET Conductivity/Resistivity Transmitter Instructions GF SIGNET 8850 Conductivity/Resistivity Transmitter Instructions ENGLISH 8850.090 A9/99 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to

More information

CDTX-45T Portable Toroidal Conductivity Meter

CDTX-45T Portable Toroidal Conductivity Meter CDTX-45T Portable Toroidal Conductivity Meter Table of Contents TABLE OF FIGURES... 4 PART 1 - INTRODUCTION... 5 1.1 General... 5 1.2 Features... 5 1.3 CDTX-45T System Specifications... 7 1.4 CDTX-45T

More information

ph 300 ph 301 ph 302 Microprocessor GLP Bench-top ph/mv/ise/ C Meters Instruction Manual

ph 300 ph 301 ph 302 Microprocessor GLP Bench-top ph/mv/ise/ C Meters Instruction Manual Instruction Manual ph 300 ph 30 ph 302 Microprocessor GLP Bench-top ph/mv/ise/ Meters Rel mv ppm ph DATE TIME MEM mv ppm ph INTV WRONG m BUF 2 s LOG 3 ON OFF PAPER PRINT ph302 ph METER RANGE / TIME PGM

More information

Instruction Sheet PN 51A-6081C/rev.A June Model 6081-C Wireless Contacting Conductivity Transmitter

Instruction Sheet PN 51A-6081C/rev.A June Model 6081-C Wireless Contacting Conductivity Transmitter Instruction Sheet PN 51A-6081C/rev.A June 2009 Model 6081-C Wireless Contacting Conductivity Transmitter ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Rosemount Analytical designs, manufactures,

More information

General Purpose ph/orp Sensor

General Purpose ph/orp Sensor Instruction Sheet PN 51A-399VP/rev.J January 2011 Model 399VP General Purpose ph/orp Sensor SPECIFICATIONS Sensor Type: General purpose 399VP Measured Range: ph: ACCUGLASS 0-14 ORP: -1500 to +1500 mv Percent

More information

High Voltage DC Meter

High Voltage DC Meter High Voltage DC Meter Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications

More information

Analytical Instruments Two-Wire ph, ORP, plon Transmitters

Analytical Instruments Two-Wire ph, ORP, plon Transmitters Data Sheet Analytical Instruments Two-Wire ph, ORP, plon Transmitters Model TB82PH Series Designed With the Real World in Mind Easy to use menus guide the operator through set-up, calibration and maintenance

More information

KOBOLD PDA Series Digital Pressure Transmitter

KOBOLD PDA Series Digital Pressure Transmitter KOBOLD PDA Series Digital Pressure Transmitter PDA-153 Series User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh, PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com

More information

Solutions to the Most Challenging Environments

Solutions to the Most Challenging Environments Solutions to the Most Challenging Environments Short Catalog Feb, 2017 AM-2300 Multi-Input, Multi-Parameter Controller Inputs for four 4-20 ma sensors of any kind in any combination: ph, ORP, conductivity,

More information

INSTRUCTION MANUAL ORP-METER MODEL COR-01

INSTRUCTION MANUAL ORP-METER MODEL COR-01 INSTRUCTION MANUAL ORP-METER MODEL COR-01 EL-221, MIDC Electronic Zone, Mhape, Navi Mumbai-400701. Tel: 022-61944000 CHAPTER 1 INTRODUCTION CONTECH ORP meter measures ph and mv, can used for Oxidation

More information

Operation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

Operation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller Operation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller 11751 Markon Drive Garden Grove, CA. 92841 U.S.A. pg. 1 CONTENTS GENERAL INTRODUCTION.....3 INITIAL INSPECTION......3

More information

Microprocessor ph/orp Controller

Microprocessor ph/orp Controller PC3030A/PC-3050 Microprocessor ph/orp Controller Operating Manual CONTENTS 1 Specifications... 2 Assembly and installation... 2.1 Precautions for installation.. 2.2 Install the controller on the wall mount

More information

ph/orp Meter SD Card real-time Datalogger

ph/orp Meter SD Card real-time Datalogger User's Guide ph/orp Meter SD Card real-time Datalogger Model SDL100 Introduction Congratulations on your purchase of the Extech SDL100 ph/orp Meter, an SD Logger Series meter. This meter displays and stores

More information

User's Guide. Online Meters. PH / ORP / TDS / Conductivity.

User's Guide. Online Meters. PH / ORP / TDS / Conductivity. User's Guide Online Meters PH / ORP / TDS / Conductivity www.rakiro.net Introduction Continuous monitoring of PH / ORP is commonly required in a wide variety of industries ranging from water, chemical,

More information

Versatile Transmitter Series For Intelligent Measurement Solutions. INGOLD Leading Process Analytics

Versatile Transmitter Series For Intelligent Measurement Solutions. INGOLD Leading Process Analytics INGOLD Leading Process Analytics Transmitter Series M400 / M420 / M300 Transmitters Extended ISM functions Easy handling Intuitive user interface Multi-parameter Versatile Transmitter Series For Intelligent

More information

Handheld Water Quality Meters 100 Series

Handheld Water Quality Meters 100 Series ph ORP Ion Conductivity Resistivity TDS DO Salinity Handheld Water Quality Meters 100 Series METERS 2 YEAR W A R R A N T Y M A D E I N J A P A N www.horiba-laqua.com In the lab, in the field or anywhere

More information

HIGH-VOLTAGE DC METER

HIGH-VOLTAGE DC METER HIGH-VOLTAGE DC METER Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications

More information

Integrated Instruction Manual WP 600 Series Meters

Integrated Instruction Manual WP 600 Series Meters Integrated Instruction Manual WP 600 Series Meters ph 600/ 610/ 620, COND 600/610, DO 600, PC 650, PD 650, CD 650, PCD 650 68X415307 Rev. 1 Oct 07 Part of Thermo Fisher Scientific Technology Made Easy...

More information

Single Parameter Meters Lightweight and versatile ph, EC and DO meters that can be used in portable, wall-mount and benchtop configurations

Single Parameter Meters Lightweight and versatile ph, EC and DO meters that can be used in portable, wall-mount and benchtop configurations Single Parameter Meters Lightweight and versatile ph, EC and DO meters that can be used in portable, wall-mount and benchtop configurations Digital electrodes edge performs measurements through its unique

More information

Instrumentation for Process Analytics

Instrumentation for Process Analytics Instrumentation for Process Analytics Transmitters, Analyzers, & Automated Systems digital and analog analytical loops Analytical Measurements Can Be Painful We re Changing the Status Quo of Process Analytics

More information

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions Specialists in Liquid Level Indication MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions Section: M500 Bulletin: M500.31 Date: 05-17-16 Supersedes: 09-30-11 1. INTRODUCTION

More information

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter Operation Manual MODEL 2TX 2-wire Isolated ph/orp Transmitter 0 2TX CONTENTS INITIAL INSPECTION.....2 INTRODUCTION......2 ASSEMBLY...3 PREPARATION....4 CONNECTING THE ELECTRODE...4 CONNECTING THE TEMPERATURE

More information

Thermo Scientific Orion Star A214 Benchtop ph/ise Meter. Instruction Sheet

Thermo Scientific Orion Star A214 Benchtop ph/ise Meter. Instruction Sheet English ph / ISE Thermo Scientific Orion Star A214 Benchtop ph/ise Meter Instruction Sheet Preparation Power Source 1. Power adapter (included with meter) a. Select the appropriate wall socket plug plate.

More information

Dissolved Oxygen Meter Kit DOK. Instruction Manual

Dissolved Oxygen Meter Kit DOK. Instruction Manual Dissolved Oxygen Meter Kit 850081DOK Instruction Manual Contact : EASTERN ENERGY CO.,LTD. (HEAD OFFICE) 40/4 Vitoondumri Rd., Banbueng, Banbueng, Chonburi 20170 Tel: 0-3844-6117, Fax: 0-3844-6200 Email:

More information

Benchtop Multi-parameter Water Quality Meter

Benchtop Multi-parameter Water Quality Meter LMPWM-A Series Benchtop multi-parameter water quality meter LMPWM-A series is comes with different measurement modes for quality and testing of water on different parameters. It measures ph, Conductivity,

More information

OPERATING INSTRUCTIONS FOR LXT-220. Dissolved Oxygen Controller DANGER

OPERATING INSTRUCTIONS FOR LXT-220. Dissolved Oxygen Controller DANGER OPERATING INSTRUCTIONS FOR LXT-220 Dissolved Oxygen Controller P/N Mxxxxx ECO: DANGER Toxic gases and or flammable liquids may be present in this monitoring system. Personal protective equipment may be

More information

Safety. 1. Installation 1.1 CR:Services 1.2 Driver Card Installation 1.3 Sensor Types 1.4 Sensor Wiring

Safety. 1. Installation 1.1 CR:Services 1.2 Driver Card Installation 1.3 Sensor Types 1.4 Sensor Wiring Safety 1. Installation 1.1 CR:Services 1.2 Driver Card Installation 1.3 Sensor Types 1.4 Sensor Wiring 2. Configuration - Operation 2.1 Setup-Calibration 2.2 Diagnostics 3. Specifications Safety 100mV

More information

English. Operating manual. Multiparameter portable instrument HD Keep for future reference. Companies / Brands of GHM

English. Operating manual. Multiparameter portable instrument HD Keep for future reference. Companies / Brands of GHM English Operating manual Multiparameter portable instrument HD98569 Companies / Brands of GHM www.deltaohm.com Keep for future reference. TABLE OF CONTENTS Introduction... 6 Display Description... 7 Keyboard

More information

+GF+ SIGNET 5800CR Conductivity/Resistivity Monitor Instructions

+GF+ SIGNET 5800CR Conductivity/Resistivity Monitor Instructions GF SIGNET 5800CR Conductivity/Resistivity Monitor Instructions ENGLISH 35800CR.0901 D1/98 CAUTION! Refer to instruction manual for more details. Remove power to unit before wiring input and output connections.

More information

Research Grade Meters. ph, ISE, EC and DO. Laboratory bench meters with a color, graphic display and capacitive touch keypad

Research Grade Meters. ph, ISE, EC and DO. Laboratory bench meters with a color, graphic display and capacitive touch keypad Research Grade Meters ph, ISE, EC and DO Laboratory bench meters with a color, graphic display and capacitive touch keypad HI5000 Series Research Grade Meters Overview HI5000 Series Research Grade Meters

More information

SIGNET ph/orp Transmitter

SIGNET ph/orp Transmitter SIGNET 8750- ph/orp Transmitter ENGLISH 3-8750.090- D-4/03 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents.

More information

DO Meter Kit. Instruction Manual

DO Meter Kit. Instruction Manual DO Meter Kit 850048 Instruction Manual DO Meter Kit 850048 Copyright 2013 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted in any

More information

ph/orp 300 (Cat. No ) MICROCOMPUTER BASED OPERATION MANUAL ph /ORP/ Temperature CONTROLLER Phone: , Fax:

ph/orp 300 (Cat. No ) MICROCOMPUTER BASED OPERATION MANUAL ph /ORP/ Temperature CONTROLLER Phone: , Fax: OPERATION MANUAL /ORP 300 (Cat. No. 0580212) MICROCOMPUTER BASED /ORP/ Temperature CONTROLLER 625 East Bunker CT, Vernon Hills, IL 60061-1844 Phone: 800-32-4340, Fax: 847-247-2929 E-mail: info@coleparmer.com,

More information

HI 3220 HI 3221 HI 3222

HI 3220 HI 3221 HI 3222 Instruction Manual HI 3220 HI 3221 HI 3222 Calibration Check ph/mv/ise/temperature Bench Meters WARRANTY The HI 322x series are guaranteed for two years against defects in workmanship and materials when

More information

Electrodes ph EC DO /14 dge 2 P/L e

Electrodes ph EC DO /14 dge 2 P/L e ph EC DO ph Resolution selectable from 0.01 and 0.001 ph Range -2.000 16.000 ph Accuracy ± 0.002 ph Data logging Manual log on demand Manual log on stability Interval logging Temperature readout ( C or

More information

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process and Ratiometric Signals Features Reads process signals from ±200 mv to ±600V or ±2 ma to ±5A full scale Ratiometric mode for bridges and

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation

More information

Multiparameter Waterproof Meters. Multiparameter measurement in compact, IP67 rated waterproof enclosures

Multiparameter Waterproof Meters. Multiparameter measurement in compact, IP67 rated waterproof enclosures Multiparameter Waterproof Meters Multiparameter measurement in compact, IP67 rated waterproof enclosures HI98194 Features HI98194 Multiparameter Waterproof Meter ph, ORP, EC, TDS, Resistivity, Salinity,

More information

KOBOLD Compact Electronics

KOBOLD Compact Electronics KOBOLD Compact Electronics User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com Manual-compactelectronics_2262002

More information

Explosion-Proof Gauge Pressure Transmitter

Explosion-Proof Gauge Pressure Transmitter Technology Solutions T EK-B AR 3120A Explosion-Proof Gauge Pressure Transmitter PRESSURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The Tek-Bar

More information

Cole-Parmer Instrument Company

Cole-Parmer Instrument Company Operating Instructions Cole-Parmer ph/orp 350 ph/orp Transmitter Cole-Parmer Instrument Company 625 East Bunker Court, Vernon Hills, Illinois 60061 Tel: 1-847-549-7600 or Toll-free: 1-800-323-4340 Fax:

More information

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph ph EC DO ph Resolution selectable from 0.01 and 0.001 ph Range -2.000 16.000 ph Accuracy ± 0.002 ph Data logging Manual log on demand manual log on stability Interval logging Temperature readout ( C or

More information

LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER

LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER The Model 1575e uses the latest in microprocessor capability, giving the user a high level of application flexibility. A large illuminated graphics

More information

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights HygroFlex & HygroClip-EX HygroFlex series may be used together with the intrinsically safe HygroClip-EX probes. The relative humidity and temperature can be displayed and output as analog signals. Calculated

More information

OPERATING INSTRUCTION MANUAL MODEL P/R60 & P/R65 DIFFERENTIAL PH & ORP PROBES

OPERATING INSTRUCTION MANUAL MODEL P/R60 & P/R65 DIFFERENTIAL PH & ORP PROBES OPERATING INSTRUCTION MANUAL MODEL P/R60 & P/R65 DIFFERENTIAL PH & ORP PROBES N116-19 REV. 10 Water Analytics, Inc. 100 School Street Andover, MA 01810 Tel: (978) 749-9949 (855) 747-7623 Fax: (978) 749-9961

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. TB84PH ph /ORP / pion transmitter

ABB MEASUREMENT & ANALYTICS DATA SHEET. TB84PH ph /ORP / pion transmitter ABB MEASUREMENT & ANALYTICS DATA SHEET TB84PH ph /ORP / pion transmitter 2 TB 8 4PH P H /ORP / P I ON TR AN S MIT TE R DS/ TB8 4PH-E N RE V. D Measurement made easy Hazardous area rated transmitter with

More information

Temperature process values at a glance

Temperature process values at a glance Temperature process values at a glance PERFORMANCE MADE SMARTER COMMUNIC AT I ON F OUND AT I O N TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY 7501 Field mounted

More information

Portavo 904 X Multi. Multiparameter Ex

Portavo 904 X Multi. Multiparameter Ex Multiparameter Ex Portavo 904 X Multi The world's only portable device for liquid analysis with ATEX approval for measurements up to zone 0/1. Ideal for applications in the process industry. For the first

More information

ph-detector PHI 04D USER'S MANUAL

ph-detector PHI 04D USER'S MANUAL ph-detector PHI 04D USER'S MANUAL Labio a.s. Praha 2005 - 2-0 Introductory: ph-detector phi 04D is a digital instrument developed for accurate potentiometric monitoring, especially for measuring ph by

More information

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR LC1 MANUAL 062114 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features Dimensions WIRING

More information

Water Quality Meter. Water Quality Meter Kit. Instruction Manual

Water Quality Meter. Water Quality Meter Kit. Instruction Manual Water Quality Meter 850081 Water Quality Meter Kit 850086 Instruction Manual Contact : EASTERN ENERGY CO.,LTD. (HEAD OFFICE) 40/4 Vitoondumri Rd., Banbueng, Banbueng, Chonburi 20170 Tel: 0-3844-6117, Fax:

More information

The Art of Measuring. Multiparameter analyzers with Fieldbus technology. For analog, digital and Memosens sensors. Stratos

The Art of Measuring. Multiparameter analyzers with Fieldbus technology. For analog, digital and Memosens sensors. Stratos The Art of Measuring. Multiparameter analyzers with Fieldbus technology. For analog, digital and Memosens sensors Multi-Talents with Bus Communication With their exceptional functionality, reliability

More information

KOBOLD TDA Series Digital Temperature Transmitter

KOBOLD TDA Series Digital Temperature Transmitter KOBOLD TDA Series Digital Temperature Transmitter TDA-15 Series User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh, PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com

More information

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR QLC MANUAL 013114 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING

More information

MODEL 692E TWO-WIRE ELECTRODELESS CONDUCTIVITY TRANSMITTER

MODEL 692E TWO-WIRE ELECTRODELESS CONDUCTIVITY TRANSMITTER Manual No. 692E Revision 5-598 MODEL 692E TWO-WIRE ELECTRODELESS CONDUCTIVITY TRANSMITTER (selectable for conductivity or % concentration measurement) INSTRUMENT SETUP GUIDE This manual contains detailed

More information

Global Water globalw.com. Global Water. Instrumentation, Inc.

Global Water globalw.com. Global Water. Instrumentation, Inc. Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 T: 800-876-1172 Int l: (979) 690-5560, Fax: (979) 690-0440 E-mail : globalw@globalw.com PC300: Process Controller

More information

Safety. 2. Configuration - Operation 2.1 RTD Selection 2.2 Driver Test Header. 3. Diagnostics 3.1 ph Input 3.2 Temperature Input

Safety. 2. Configuration - Operation 2.1 RTD Selection 2.2 Driver Test Header. 3. Diagnostics 3.1 ph Input 3.2 Temperature Input Safety 1. Installation 1.1 PT:Services 1.2 erature Compensation of 1.3 Controller Services 1.4 Driver Card Installation 1.5 Sensor Part Numbers 1.6 Sensor Wiring 2. Configuration - Operation 2.1 Selection

More information

CII: Current Input, Isolated

CII: Current Input, Isolated Safety 1. Application CII Driver Card 2. Installation 2.1 Services 2.2 Driver Card Installation 2.3 Driver Wiring 3. Configuration - Operation 3.1 Diagnostics 3.2 Calibration 4. Specifications Safety Electrical

More information

Engineering Note: EN0047 Commissioning a Hydro-Probe with a Command Alkon EZCal Station

Engineering Note: EN0047 Commissioning a Hydro-Probe with a Command Alkon EZCal Station Engineering Note: EN0047 Commissioning a Hydro-Probe with a Command Alkon EZCal Station Summary: Products affected: Commissioning a Hydro-Probe with a Command Alkon EZCal Manual Station Hydro-Probe Models

More information

Cole-Parmer Instrument Company

Cole-Parmer Instrument Company Operating Instructions Cole-Parmer ph/orp 400 ph/orp Controller Cole-Parmer Instrument Company 625 East Bunker Court, Vernon Hills, Illinois 60061 Tel: 1-847-549-7600 or Toll-free: 1-800-323-4340 Fax:

More information

User Manual DOCUMENT #601119REF. EcoSense ph1000a. ph, mv (ORP), and Temperature Benchtop Meter USER MANUAL. English

User Manual DOCUMENT #601119REF. EcoSense ph1000a. ph, mv (ORP), and Temperature Benchtop Meter USER MANUAL. English User Manual DOCUMENT #601119REF EcoSense ph1000a ph, mv (ORP), and Temperature Benchtop Meter USER MANUAL English Item #601119REF Rev C, October 2017 For the latest version of this manual, visit ysi.com

More information

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual K0 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual Pneumatic Connection Single Acting Actuator (Spring Return): For single acting actuators Outlet Port 2 is to be plugged. Outlet Port

More information

ABB Automation. Advantage Series ph/orp/pion Analyzer. Type TB84pH. Specification. Simple menu programming (patent pending).

ABB Automation. Advantage Series ph/orp/pion Analyzer. Type TB84pH. Specification. Simple menu programming (patent pending). Type TB84pH Advantage Series ph/orp/pion Analyzer Specification Simple menu programming (patent pending). Online continuous sensor diagnostics. Two fully programmable isolated outputs: Zero to 20 ma and

More information

! Ranges from -45º to 650ºC. ! Rapid heating, cooling and settling. ! Switch test, ramp, step and preset functions

! Ranges from -45º to 650ºC. ! Rapid heating, cooling and settling. ! Switch test, ramp, step and preset functions DBC SERIES DBC 150/650 Series Dry Block Temperature Calibrators 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com! s from -45º to 650ºC! Rapid heating, cooling and settling!

More information

Series ULT Ultrasonic Level Transmitter

Series ULT Ultrasonic Level Transmitter Bulletin L-45 Series ULT Ultrasonic Level Transmitter Specifications - Installation and Operating Instructions 3 29/32 [99.21] 4 9/32 [108.74] 2X 1/2 NPT ø3 21/64 [84.53] 8 1/16 [204.79] Series ULT Ultrasonic

More information

GeneMate Benchtop ph Meters Operation Manual

GeneMate Benchtop ph Meters Operation Manual GeneMate Benchtop ph Meters Operation Manual TABLE OF CONTENTS SAFETY PRECAUTIONS.. 1 GETTING STARTED.... 1 INTRODUCTION..... 2 METER OVERVIEW..... 3 ph, mv & OXYGEN REDUCTION POTENTIAL (ORP) MEASUREMENT....

More information

Instruction Manual PN pH/rev.C April Model 2081 ph. Smart Microprocessor Analyzer

Instruction Manual PN pH/rev.C April Model 2081 ph. Smart Microprocessor Analyzer Instruction Manual PN 51-2081pH/rev.C April 2003 Model 2081 ph Smart Microprocessor Analyzer ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Rosemount Analytical designs, manufactures, and tests

More information

HI 9828 Multiparameter Water Quality Meter...

HI 9828 Multiparameter Water Quality Meter... HI 9828 Multiparameter Water Quality Meter... Backlit LCD can display up to 12 Measurements at a time Feature Highlights Display up to 12 parameters Graphic LCD with backlight Meter features IP67 and probe

More information

Transmitter / Controller Series J dtrans ph 01, Rd 01, Lf 01, Rw 01, Az 01

Transmitter / Controller Series J dtrans ph 01, Rd 01, Lf 01, Rw 01, Az 01 Transmitter / Controller Series J dtrans ph 01, Rd 01, Lf 01, Rw 01, Az 01 with C-UL-US approval PR 20004 GB ph mv ms/cm µs/cm M xcm Transmitter / Controller Series J dtrans ph 01, Rd 01, Lf 01, Rw 01,

More information

Control instruments GUARDIAN 2 - GUARDIAN 3

Control instruments GUARDIAN 2 - GUARDIAN 3 Control instruments GUARDIAN 2 - GUARDIAN 3 Table of contents 1. General informations... 3 2. Technical data... 3 3. GUARDIAN 2 connection diagram...4 3.1. TTL connection diagram for GUARDIAN 2 instrument...5

More information

TB84TE Conductivity transmitter 2-Electrode. Superior accuracy in low conductivity and pure water. applications

TB84TE Conductivity transmitter 2-Electrode. Superior accuracy in low conductivity and pure water. applications Data sheet DS/TB84TE EN Rev. C TB84TE Conductivity transmitter 2-Electrode Superior accuracy in low conductivity and pure water applications Smart key menu programming Superior accuracy in low conductivity

More information

Model 620A Maintenance and Calibration

Model 620A Maintenance and Calibration Model 0A Maintenance and Calibration CAUTION! See Ch Pg, A & B below prior to connecting inputs to TB of the A PCB. Determine Rev. of the A board on the Model 0/0A for correct input connections. Failure

More information

Operations Manual EcoSense ph100a

Operations Manual EcoSense ph100a Operations Manual EcoSense ph100a Portable ph, mv and Temperature Instrument English CONTENTS GENERAL INTRODUCTION... 3 INITIAL INSPECTION... 3 THE INSTRUMENT... 3 BATTERY INSTALLATION... 3 Battery Disposal...

More information

Do not open when energized or when an explosive atmosphere is present. Electrostatic hazard, clean only with damp cloth.

Do not open when energized or when an explosive atmosphere is present. Electrostatic hazard, clean only with damp cloth. D460/D470 Series - ATEX certified position transmitter nnnn II 2 GD ITS 11 ATEX 17431X Ex d IIC T* Gb Tamb -*ºC to +*ºC Ex tb IIIC T* Db Tamb -*ºC to +*ºC IP6X Ambient variation -60 C to +110 C (T4/T130

More information