We measure it. Everything under control: With testo Saveris TM, measurement data are under control everywhere.
|
|
- Rodney Dean
- 5 years ago
- Views:
Transcription
1 We measure it. Everything under control: With testo Saveris TM, measurement data are under control everywhere.
2 Saveris testo Saveris TM : Easy, safe and efficient measurement data monitoring The data monitoring system testo Saveris measures the temperature and humidity values of sensitive goods and products in ambient as well as in process conditions. The easy-to-use measurement system delivers safety and savings in time and costs thanks to automated measurement data recording. The transfer of the data takes place by wireless and/or Ethernet connection to a base station. This documents and monitors all measurement data. If limit values are exceeded, a whole range of different alarm options, such as SMS/ alarm or alarm relay is available. Remote alarms can even be given when the system is not connected to a running PC. 2
3 We measure it. In addition to this, transmitters of all measurement parameters with standard current/voltage interfaces can be integrated into the Saveris system. The integration of Testo transmitters as well as those of other manufacturers is possible. All recorded data are stored centrally in a software. At the same time, the Saveris software allows the extensive analysis and evaluation of all data gathered. 3
4 Saveris testo Saveris system overview Data monitoring for uninterrupted checks testo Saveris TM wireless probe Probe versions with internal and external temperature and humidity sensors allow the adaptation to every application. The radio probes are available with or without a display as an option. Current measurement data, the battery status and the quality of the radio link are shown on the display. testo Saveris TM router The radio link can be improved or lengthened in poor structural conditions by using a router. Several routers can of course be used in the testo Saveris system. At the same time, the serial switching of up to 3 routers V 2.0 offers highest flexibility in the wireless range. testo Saveris TM converter Through the connection of a converter to an Ethernet jack, the signal of a radio probe can be converted into an Ethernet signal. This combines the flexible connection of the radio probe with the use of the existing Ethernet even over long transmission paths. testo Saveris TM router V 2.0 testo Saveris TM converter V 2.0 Ethernet testo Saveris TM wireless probe testo Saveris TM analog coupler (Ethernet) testo Saveris TM analog coupler (wireless) Humidity transmitters testo Saveris TM analog coupler The two versions of the analog coupler (wireless / Ethernet) allow the inclusion of other measurement parameters into the testo Saveris monitoring system, by integrating all measurement transmitters with standarized current/voltage interfaces, e. g. 4 to 20 ma or 0 to 10 V. Humidity transmitters testo 6651/6681/6351/6381 Thanks to the integration of the humidity and differential pressure transmitters, measurement data monitoring is possible parallel to the control. This provides the solution for highest accuracy as well as for special applications (high humidity, trace humidity etc.) in compressed air, drying and air conditioning technology and in cleanroom applications. Find out more at 4
5 We measure it. testo Saveris TM Base The base is the heart of testo Saveris and can save 40,000 readings per measurement channel independently of the PC. This corresponds to around one year of memory capacity at a measuring rate of 15 minutes. The system data and alarms are visible via the display of the Saveris base. testo Saveris TM software The testo Saveris software offers simple operation and an intuitive user interface. The Saveris software is available in three different versions: as the basic version SBE (Small Business Edition), the PROF (Professional) software version with diverse additional options, or as the CFR version. The CFR software fulfils the requirements of the FDA s 21 CFR Part 11 and is thus validatable. Ethernet USB or Ethernet testo Saveris TM Base Ethernet testo Saveris TM Ethernet probe testo Saveris TM Software testo Saveris TM Ethernet probe In addition to the radio probes, probes can be used that are directly connected to the Ethernet. The existing LAN infrastructure can be used through this. This allows the data transfer from the probe to the base, even over long distances. 5
6 Saveris Overview of testo Saveris TM application areas Monitoring the foodstuff cooling chain Compliance with predefined temperature values is a decisive factor for quality in food production and is important for complying with legal hygiene standards. testo Saveris automates not only the monitoring of the ambient and production temperatures during production and storage, but also of defined temperature limit values during transport. The installation of wireless probes in delivery vehicles makes the complicated wiring of the driver s cabin unnecessary. Alarms are issued whenever the limit values are exceeded. The measurement data and any occurring alarms are saved centrally in a database and are accessible at any time. testo Saveris conforms to the EN standard. 6
7 We measure it. Monitoring in production, quality assurance and storage in industry In industry, a number of quality data must be recorded and monitored in the production, quality assurance and storage of products. testo Saveris automates the documentation of these data and alarms when limit values are exceeded. Products and processes are thus guaranteed at a high level of quality. testo Saveris is ideal for use in the monitoring and documentation of ambient and temperature data in production areas, storerooms, refrigerators and climate cabinets. The most varied applications are optimally covered by testo Saveris radio probes and/or Ethernet probes. 7
8 Saveris Overview of testo Saveris TM application areas Monitoring of processes in the pharmaceutical industry In the pharmaceutical industry, high demands are placed on the recording and monitoring of quality parameters. Constant documentation and monitoring during the production and storage of temperature-sensitive products such as medicines, blood products or cell cultures has long been considered an absolute must. testo Saveris automates the central documentation of measurement data as well as the safe monitoring of refrigerated and deep-freeze rooms, incubators and climate cabinets. The comprehensive alarm management allows fast alarming if limit values are violated. Thanks to a combination of wireless and/or Ethernet probes, the system is optimum for many different applications in the pharmaceutical industry. It goes without saying that the data monitoring system testo Saveris meets the requirements of 21 CFR Part 11. 8
9 We measure it. Monitoring of the building climate When monitoring the building climate, stable ambient conditions are especially necessary in museums and archives in order to protect sensitive and valuable objects. testo Saveris automates the central recording of all climate data. By issuing alarms when limit values are exceeded, testo Saveris protects valuable inventory from undesired temperature or humidity influences at all times. The radio probe can be flexibly attached to locations without the effort of routing cables. Monitoring of processes in research and development, laboratories and hospitals Research and development areas as well as laboratories and hospitals are responsible for the recording of ambient and process data in order to monitor sensitive products or machines. testo Saveris carries out the central documentation and monitoring of the measurement series. testo Saveris thus guarantees the simple and ure monitoring of climate and process data in air conditioning chambers, refrigerators, drying chambers, test benches or blood banks. At the same time, the Saveris software allows the extensive analysis and evaluation of all measurement data gathered. 9
10 Saveris testo Saveris software 1 Installation made easy Connect Saveris base to mains. The probes can now be logged on at the base: They are switched on in series and automatically identified by the base. The Saveris base is connected to the PC via USB or Ethernet. The software is installed on the PC with help from the installation wizard. The system is ready for configuration: Probe name, limit values, measuring cycles and alarms can be adapted to the individual measuring tasks. 2 Clear and always up-to-date The measurement data can always be shown as a graphic or table. Various probes can be compiled into groups. Logical units by measurement task are thus formed. The measurement data view over days, weeks or months is freely definable. The integrated calendar offers practical assistance here. Daily report Cold storage house zone: Hourly mean values on Time C freezer 1 %RH cold room 1 C refrigerator C drinks C freezer 2 C freezer 3 C freezer 4 3 Automated documentation Form and time of the reporting are predefined once. The creation and saving of reports as a PDF file now takes place automatically in accordance with the set conditions. The files are therefore ready to be printed at any time. Total maximum value Total mean value Total minimum value 10
11 We measure it. Small Business Edition (SBE), Professional (PROF) and CFR version Now more flexible with Professional software 4 The PROF (Professional) software version offers interesting additional functions beyond the attractive standard functions of the basic version SBE, e.g.: Client-server concept: The measurement data can be monitored by various PCs integrated into the network. Photographs of machines or rooms can be saved as a picture. The respective measurement values are shown directly at the position of the probe in the room or at the machine in these. The link between the location and the measurement value is thus very easily visualized (fig. 4). A comprehensive alarm management offers the option of alarming more than two people at the same time or in succession. Depending on the day of the week or the time, it is possible to choose whether the alarm is given as an and/or an SMS. 21 C 48 %RH 41 C 22 %RH 26 C 38 %RH Validatable CFR software 5 The CFR software fulfils the requirements of the FDA s 21 CFR Part 11 and is thus validatable. Overview of software features SBE PROF CFR Diagrams / tables / Alarm overview / PDF reports Calendar management Presentation of probe groups Alarm dispatch ( , SMS, relay) Comprehensive alarm management Automated update of measurement data ( Online mode ) Measurement data on background photo of measruement sites Integration in network (client-server) Allocation of access rights for stationary and mobile probe groups 21 CFR Part 11 compliant (validatable) Electronic signature Audit trail for tracing user activity Allocation of access rights on 3 user levels SBE software, incl. USB connecting cable base-pc PROF software, incl. USB connecting cable base-pc CFR software, incl. Ethernet connecting cable base-pc
12 Saveris testo Saveris Base The base is the heart of testo Saveris and can save 40,000 readings per measurement channel independently of the PC. The system data and alarms are visible via the display of the Saveris base. Display for showing alarms and system data Large data memory Issue of alarms via LED/relay SMS alarm (optional) Emergency battery integrated Up to 150 probes can be connected Connection option via USB or Ethernet Technical data Memory Dimensions Weight Protection class Housing material Radio frequency Power supply (absolutely necessary) Rech. batt. Oper. temp. Storage temp. Display Interfaces Connectable radio probe 40,000 values per channel (total max values) 225 x 150 x 49 mm approx g IP42 Die-cast zinc/plastic 2.4 GHz 6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals, power consumption 4 W Li-ion battery (for data back-up and for emergency SMS with failure of the power supply) -10 to +50 C -40 to +60 C graphical display, 4 control keys USB, radio, Ethernet max. 15 probes can be directly connected via radio interface, max. 150 total via radio / Router / Converter / Ethernet, max. 450 channels Alarm relay max. 1 A, max. 30 W, max. 60/25 V DC/AC, NC or NO contact GSM module 850/900/1800/1900 MHz not valid for Japan and South Korea Set up Table base and wall bracket included Firmware Version 2.X Ordering data 2.4 GHz Saveris base, radio frequency 868 MHz Note on the radio frequencies 2.4 GHz: non EU countries 2.4 GHz Saveris base, radio frequency 868 MHz, GSM module integrated (for SMS alarm) No mains units or antennas with magnetic base are contained in this ordering data. 12
13 We measure it. testo Saveris components: Router und Converter The radio link can be improved or lengthened in poor structural conditions by using a router. Several routers can of course be used in the testo Saveris system. At the same time, the serial switching of up to 3 routers V 2.0 offers highest flexibility in the wireless range. Through the connection of a converter to an Ethernet jack, the signal of a radio probe can be converted into an Ethernet signal. This combines the flexible connection of the radio probe with the use of the existing Ethernet even over long transmission paths. Radio Radio Radio Radio Ethernet Ethernet Saveris Router V 1.0 Saveris Router V 2.0 Saveris Converter V 1.0 Saveris Converter V 2.0 Use for Saveris Base Firmware Version V 1.X for Saveris Base Firmware Version V 2.X for Saveris Base Firmware Version V 1.X nonly for wireless probes Firmware Version 1.x for all Saveris Base Firmware versions only for wireless probes with Firmware Version V 2.X Dimensions Weight Power supply approx. 180 g 6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals, power consumption approx. 85 x 100 x 38 mm approx. 190 g 6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals, PoE, power consumption Oper. temp. Storage temp. Housing material Protection class Interfaces Connectable radio probe Router cascading Wall holder -20 to +50 C -40 to +60 C Plastic IP54 Radio Radio, Ethernet max. 5 max. 15 No Yes included 2.4 GHz Versions Saveris router, V 1.0,868 MHz, radio transmission medium Saveris router, V 2.0,868 MHz, radio transmission medium Saveris Cverter V 1.0, 868 MHz, converts the radio transmission medium to Ethernet Saveris Cverter V 2.0, 868 MHz, converts the radio transmission medium to Ethernet No mains units are contained in this ordering data. 13
14 Saveris testo Saveris components: Radio probe Probe versions with internal and external temperature sensors and with humidity sensors allow the adaptation to every application. The radio probes are available with or without a display as an option. Current measurement data, the battery status and the quality of the radio link are shown on the display. NTC internal 81 mm NTC internal 81 mm C / F TC external 81 mm TC external 81 mm Pt 100 external Internal sensor External probe Radio Probe type Measuring range Accuracy Resolution Probe type Measuring range (instrument) Accuracy (instrument) Resolution (instrument) Connection Saveris T1 Radio probe with internal NTC NTC -35 to +50 C ± 0.4 C (-25 to +50 C) ±0.8 C (remaining meas. range) 0.1 C Saveris T2 Radio probe with external probe connection and internal NTC, door contact NTC -35 to +50 C ± 0.4 C (-25 to +50 C) ±0.8 C (remaining meas. range) 0.1 C NTC -50 to +150 C ± 0.2 C (-25 to +70 C) ±0.4 C (remaining meas. range) 0.1 C NTC via Mini DIN socket, Door contact connection cable included in delivery (1.80 m) Saveris T3 2-channel radio probe with 2 external TC probe connections (TC characteristics can be selected) 0.1 C / TC Type S 1 C 2 TCs via TC socket, max. difference in potential 2 V Saveris Pt Radio probe with 1 external Pt100 probe connection TC Type K TC Type J Pt to C -100 to +750 C -200 to +600 C TC type T TC type S -200 to +400 C 0 to C ±0.5 C or 0.5% of reading) at +25 C ± 0.1 C (0 to +60 C) ±0.2 C (-100 to +200 C) ±0.5 C (remaining meas. range) 0.01 C 1 Pt100 via mini-din socket Dimensions (housing): Weight Battery life (Type: 4 x AA) Housing material Protection class Radio frequency Meas. cycle Memory Conformity with standards Oper. temp. Storage temp. Display (optional) Transmission distance Wall holder IP68 DIN EN to +50 C 80 x 85 x 38 mm approx. 240 g Battery life 3 years at +25 C; 3 years with Energizer L91 Photo lithium batteries for freezer applications Plastic IP GHz Standard 15 min, can be set from 1 min up to 24 h readings per channel -40 to +55 C (incl. batteries) 2-line LCD; 7 segments with symbols approx. 100 m free field at a frequency of 2.4 GHz included -20 to +50 C IP68 Versions Version without display Saveris T * 2.4 GHz Version with display Saveris T1 D * Saveris T * Saveris T2 D * Saveris T * Saveris T3 D * Saveris Pt * Saveris Pt D * The AA alkali manganese mignon batteries ( ) are contained in this ordering data (excepting analog coupler). Saveris probes are delivered with a calibration protocol of the works adjustment data. Calibration certificates must be ordered separately. * The Saveris Converter V 2.0 (order no ) is required for integration of Saveris wireless probes into systems with Base firmware V 1.X For more information please contact your Testo partner. 14
15 We measure it. testo Saveris components: Radio probe % RH NTC C / F and %RH % RH NTC % RH NTC ma V ma and V external internal external internal Radio Saveris H2 D Humidity radio probe Saveris H3 Humidity radio probe Saveris H4 D Radio probe with 1 external humidity probe connection Saveris U1 Radio probe with current/voltage input Internal sensor Probe type Measuring range Accuracy NTC Resolution 0.1 C Probe type NTC Humidity sensor Meas. range (instrument) -20 to +50 C 0 to +100 %RH 2) Accuracy (instrument) ± 0.5 C to 90 %RH: ±2 %RH at +25 C > 90 %RH: ±3 %RH at +25 C ±0,03 %RH/K ± 1 Digit Resolution (instrument) 0.1 C 0,1%/0.1 Ctd Connection fixed stump probe External probe -20 to +50 C ± 0.5 C Humidity sensor %RH ±3 %RH at +25 C ±0,03 %RH/K ±1 Digit 0.1 % / 0.1 Ctd NTC -20 to +70 Humidity sensor 0 to +100 %RH 2) ± 0.2 C see probes 0.1 C 0,1%/0.1 Ctd 1 x external humidity probe Mini DIN socket 1 channel: Current/voltage input 2-wire: ma 4-wire: 0/ ma, 0 to 1/5/10 V, load: max. 160 Ω at 24 V DC Current ±0.03 ma / 0.75 μa Voltage 0 to 1 V ±1.5 mv/39 μv Voltage 0 to 5 V ±7.5 mv / 0.17 mv Voltage 0 to 10 V ±15 mv / 0,34 mv ±0.02% of m.v./k deviating from nominal temperature 22 C 2/4-wire current/voltage input Service interface Mini DIN for adjustment Dimensions (housing): Weight Battery life (Type: 4 x AA) Housing material Protection class Radio frequency Meas. cycle Memory Oper. temp. Storage temp. Display (optional) Transmission distance Wall holder 85 x 100 x 38 mm approx. 256 g IP54 80 x 85 x 38 mm approx. 245 g Batery life 3 years at +25 C; 3 years with Energizer L91 Photo lithium batteries for freezer applications Plastic IP GHz Standard 15 min, can be set from 1 min up to 24 h readings per channel -20 to +50 C -40 to +55 C (incl. batteries) 2-line LCD; 7 segments with symbols approx. 100 m free field at a frequency of 2.4 GHz included approx. 85 x 100 x 38 mm approx. 240 g Supply: Mains unit 6.3 V DC, 20 to 30 V DC max. 25 V AC IP54 (no display) Versions Version without display 2.4 GHz Version with display Saveris H2 D * Saveris H * Saveris H3 D * Saveris H4 D * Saveris U * The AA alkali manganese mignon batteries ( ) are contained in this ordering data (excepting analog coupler). Saveris probes are delivered with a calibration protocol of the works adjustment data. Calibration certificates must be ordered separately. 1) Not for condensing atmosphere. For continuous applications in high humidity (>80 %RH at 30 C for >12 h, >60 %RH at >30 C for >12h), please contact us via * The Saveris Converter V 2.0 (order no ) is required for integration of Saveris wireless probes into systems with Base firmware V 1.X For more information please contact your Testo partner. 15
16 Saveris testo Saveris components: Ethernet probes The existing LAN infrastructure can be used through the Ethernet probe. This allows the data transfer from the probe to the base, even over long distances. Ethernet probes have a display. NTC external TC external C Pt 100 external Ethernet Saveris T1 E Saveris T4 E Saveris Pt E Ethernet probe with external NTC probe connection 4-channel Ethernet probe with 4 external TC probe connections Ethernet probe with external Pt100 probe connection External probe Probe type Measuring range (instrument) Accuracy (instrument) Resolution (instrument) Connection Dimensions (housing): Weight Supply Buffer battery Housing material Protection class Meas. cycle Memory Oper. temp. Storage temp. NTC -50 to +150 C ± 0.2 C (-25 to +70 C) ±0.4 C (remaining meas. range) 0.1 C 1 NTC via mini-din socket TC Type K TC Type J -195 to C -100 to +750 C TC type T TC type S -200 to +400 C 0 to C ±0.5 C or 0.5% of reading) 0.1 C / TC Type S 1 C 4 TCs via TC socket max. potential difference 50 V Mini-DIN service interface for adjustment is accessible externally Li-ion Plastic IP54 2 to 24 h readings per channel -20 to +60 C -40 to +60 C Pt to +600 C approx. 85 x 100 x 38 mm approx. 220 g 6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals, PoE Power consumption PoE Class 0 (typically 3 W) Display (optional) 2-line LCD; 7 segments with symbols Wall holder included Versions Saveris T1 E Saveris T4 E With display With display at +25 C ± 0.1 C (0 to +60 C) ±0.2 C (-100 to +200 C) ±0.5 C (remaining meas. range) 0.01 C 1 Pt100 via mini-din socket Saveris Pt E With display Saveris probes are delivered with a calibration protocol of the works adjustment data. Calibration certificates must be ordered separately. Mains units are not included in delivery. 16
17 We measure it. testo Saveris components: Ethernet probes % RH NTC % RH NTC C / F and %RH % RH NTC ma V ma and V external external external internal Ethernet Saveris H1 E Saveris H2 E Saveris H4 E Saveris U1 E Humidity Ethernet probe 1% Humidity Ethernet probe 2 % Ethernet probe with external humidity probe connection Radio probe with current/voltage input Probe type 1 channel: Current/voltage input Internal sensor External probe Measuring range Accuracy Probe type Measuring range (instrument) Accuracy (instrument) Resolution (instrument) Connection Dimensions (housing): Weight Supply Buffer battery Housing material Protection class Meas. cycle Memory NTC -20 to +70 C ± 0.2 C (0 to +30 C) ±0.5 C (remaining meas. range) 0.1 C Humidity sensor 0 to 100 %RH 1) to 90 %RH: ±(1 %RH +0.7 % of m.v.) at +25 C > 90 %RH: ±(1.4 %RH +0.7 % of m.v.) at +25 C 0.1% / 0.1 Ctd NTC -20 to +70 C ±0.5 C 0.1 C Humidity sensor 0 to 100 %RH 1) NTC -20 to +70 C 1) Humidity sensor 0 to 100 %RH 1) to 90 %RH: ±2 %rh ± 0.2 C see external probes at +25 C > 90 %RH: ±3 %rf at +25 C ± 0,03 %RH/K ± 1 Digit 0.1% / 0.1 Ctd 0.1 C 0.1%/0.1 Ctd 1 x external humidity probe Mini DIN socket Mini-DIN service interface for adjustment is accessible externally approx. 85 x 100 x 38 mm approx. 230 g approx. 254 g 6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals, PoE Li-ion Plastic IP54 2 to 24 h readings per channel Oper. temp. -20 to +60 C Storage temp. -40 to +60 C Power consumption PoE Class 0 (typically 3 W) Display (optional) 2-line LCD; 7 segments with symbols Wall holder included Versions Saveris H1 E Saveris H2 E Saveris H4 E With display With display With display wire: ma 4-wire: 0/ ma, 0 to 1/5/10V, load: max. 160 Ω at 24 V DC Current ±0.03 ma / 0.75 μa Voltage 0 to 1 V ±1.5 mv / 39 μv Voltage 0 to 5 V ±7.5 mv / 0.17 mv Voltage 0 to 10 V ±15 mv / 0.34 mv ±0.02% of m.v./k deviating from nominal temperature 22 C 1 x 2/4-wire current/voltage input Saveris U1 E no display Saveris probes are delivered with a calibration protocol of the works adjustment data. Calibration certificates must be ordered separately. Mains units are not included in delivery. 1) Not for condensing atmosphere. For continuous applications in high humidity (>80 %RH at 30 C for >12 h, >60 %RH at >30 C for >12h), please contact us via approx. 240 g no display Sintered caps for Saveris H1 E, H2 E and H2 D Ethernet probes Metal protective cap, Ø 12 mm for humidity probes, for measurement at flow velocities les than 10 m/s Stainless steel sintered filter, pore size 100 μm, sensor protection for dusty atmospheres or higher flow velocities, for measurement in high flow velocities or contaminated air Cap with wire fabric filter, Ø 12 mm Sintered PTFE filter, Ø 12 mm, for aggressive media, high-humidity applications (long-term measurements), high flow velocities) Testo saline pots for monitoring and humidity adjustment of humidity probes, 11.3% RH and 75.3% RH, incl. adapter for humidity probe, quick check or calibration of humidity probe
18 Saveris testo Saveris accessories: External temperature probes Pt Plug-in probes 100 Robust, Pt100 stainless steel food probe (IP65) Penetration probe Pt100 with ribbon cable, cable length 2 m, IP 54 Illustration Meas. range Accuracy t99 Ø 4 mm Connection: Fixed cable extended Connection cable for unlimited Pt100 stationary probes (4-wire technology), Cable length: 3 m, possible max. cable length: 20 m 125 mm 60 mm Ø 5 mm 15 mm Ø 3 mm 30 mm Ø 3.6 mm -50 to +400 C -50 to +180 C Class A (-50 to +300 C), Class B (rem. meas. range) Class A TC Plug-in probes Illustration Meas. range Accuracy t99 Stationary probe with stainless steel sheath, TC Type K Penetration probe TC with ribbon cable, Type K, cable length 2 m, IP 54 Magnetic probe, adhesive power approx. 20 N, with magnets, for measurements on metal surfaces, TC type K Magnetic probe, adhesive power approx. 10 N, with magnets, for higher temperatures, for measurements on metal surfaces, TC type K Pipe wrap probe for pipe diameters from 5-65 mm, with exchangeable measuring head, measuring range briefly up to +280 C, TC type K Pipe wrap probe with Velcro tape, for measuring temperatures on pipes with diameters up to max. 120 mm, Tmax +120 C, TC type K 40 mm Ø 6 mm Connection: Fixed cable 1.9 m 35 mm Fixed cable extended 75 mm Ø 20 mm Connection: Fixed cable 1.6 m 60 mm Ø 5 mm Ø 21 mm Connection: Fixed cable 1.2 m 395 mm 20 mm -50 to +205 C Class 2* to +170 C Class 2* to +400 C Class 2* -60 to +130 C Class 2* 5-50 to +120 C Class 1* Connection: Fixed cable 1.5 m Thermocouple with TC plug, flexible, length mm -50 to +400 C Class 2* mm, fibreglass, TC Type K Ø 1.5 mm Thermocouple with TC plug, flexible, length mm -50 to +400 C Class 2* mm, fibreglass, TC Type K Ø 1.5 mm Thermocouple with TC plug, flexible, length mm -50 to +250 C Class 2* mm, fibreglass, TC Type K Ø 1.5 mm Immersion measuring tip, flexible, TC type K 500 mm -200 to Class 1* Ø 1.5 mm C Immersion measuring tip, flexible, for measurements in air/exhaust gases (not suitable for mea mm C -200 to Class 1* surements in smelters Ø 3 mm 30 mm Ø 3.6 mm -40 to C Class The specified accuracy class of the Saveris radio and Ethernet probe is achieved using these external probes. *Acc. to norm EN , the accuracy of Class 1 refers to -40 to C (Type K), Class 2 to -40 to C (Type K), Class 3 to -200 to +40 C (Type K). 18
19 We measure it. testo Saveris accessories: External temperature and humidity probes NTC Plug-in probes Illustration Meas. range Probe accuracy t99 Stump probe, IP mm Ø 3 mm -20 to +70 ± 0.2 C (-20 to +40 C) ±0.4 C (+40.1 to +70 C) Stationary probe with aluminium sleeve, IP mm -30 to +90 C ± 0.2 C (0 to +70 C) * Ø 6 mm ±0.5 C (remaining meas. range) 190 Connection: Fixed cable; Cable length: 2.4 m Accurate immersion/penetration probe, cable 40 mm -35 to +80 C ± 0.2 C (-25 to C) * length 6 m, IP 67 Ø 3 mm Ø 3 mm ±0.4 C (remaining meas. range) 5 Connection: Fixed cable; Cable length: 6 m Accurate immersion/penetration probe, cable 40 mm -35 to +80 C ± 0.2 C (-25 to C) * length 1,5 m, IP 67 Ø 3 mm Ø 3 mm ±0.4 C (remaining meas. range) Connection: Fixed cable; Cable length: 1.5 m Penetration probe NTC with ribbon cable, cable length 2 m, IP 54 Wall surface temperature probe, e. g. for proof of structural damage in buildings Stainless steel NTC food probe (IP65) with PU line Pipe wrap probe with Velcro tape for pipe diameters of up to max. 75 mm, Tmax. +75 C, NTC 60 mm Ø 5 mm 30 mm Ø 3.6 mm Connection: Fixed cable; Cable length: 3 m 125 mm 15 mm Ø 4 mm Ø 3 mm Connection: Fixed cable; Cable length: 1.6 m 300 mm Connection: Fixed cable; Cable length: 1.5 m 30 mm -40 to +125 C ±0.5 % of reading (+100 to +125 C) ±0.2 C (-25 to +80 C) ±0.4 C (remaining meas. range) 8-50 to +80 C ± 0.2 C (0 to +70 C) to +150 C 2) ±0.5 % of reading (+100 to +150 C) 8 ±0.2 C (-25 to C) ±0.4 C (remaining meas. range) -50 to +70 ± 0.2 C (-25 to +70 C) ±0.4 C (-50 to C) * % RH Plug-in probes Illustration Meas. range Accuracy Humidity / temperature probe 12 mm -20 to +70 C, ±0,3 C Ø 12 mm 0 to +100 %RH ±2 %RH at +25 C ( %RH) ±0.03 %rf ±1 Digit Humidity / temperature probe 4 mm Ø 4 mm 0 to +40 C, 0 to +100 %RH ±0,3 C ±2 %RH at +25 C ( %RH) ±0.08 %rf ±1 Digit The specified accuracy class of the Saveris radio and Ethernet probe is achieved using these external probes. *Probe tested according to EN for suitability for the areas of transport and storage 2) Long-term measuring range to +125 C, briefly to +150 C or +140 C (2 minutes) 19
20 Saveris testo Saveris : Accessories Power supply Spare batteries for radio probes (4 x AA alkali manganese mignon batteries) Spare batteries for radio probes for operation below -10 C (4 x Energizer L91 Photo lithium) International mains unit V AC / 6.3 V DC; for mains operation or battery charging in intrument Mains unit (top-hat rail mounting) 90 to 264 VAC / 24 VDC (2.5 A) Mains unit (desktop) 110 to 240 VAC / 24 VDC (350 ma) Miscellaneous Magnetic foot aerial (dual band) 1 2 Magnetic foot aerial (dual band) with 3 m cable, for Base with GSM module (not suitable for USA, Canada, Chile, Argentina, Mexico) Antenna with magnetic foot (quad band) for Base with GSM module Alarm module (optical + audible), connectable to Base alarm relay, Ø 70 x 164 mm, 24 V AC/DC / 320 ma, permanent light: rot, permanent tone: buzzer approx. 2.4 khz (mains unit required) ID-No /1 2 Programming adapter (from Mini DIN to USB) for Base, Ethernet probes and Converters Saveris protective housing for protection from high-pressure cleaning and impact, IP 69 K suitable for wireless probes T1 / T1D / T2 / T2D / Pt / PtD / H4D Software SBE software, incl. USB connecting cable base-pc PROF software, incl. USB connecting cable base-pc CFR software, incl. Ethernet connecting cable base-pc Saveris adjustment software incl. connection cable to wireless and Ethernet probes Calibration certificates ISO temperature calibration certificate; temperature probe; calibration points -8 C, 0 C, +40 C; per channel/instrument (suitable for Saveris T1/T2) ISO temperature calibration certificate; temperature probe; calibration points -18 C, 0 C, +60 C; per channel/instrument (suitable for Saveris T1/T2) DAkkS temperature calibration certificate*; temperature probe; calibration points -20 C, 0 C, +60 C; per channel/instrument (suitable for Saveris T1/T2) ISO humidity calibration certificate; humidity probe; calibration points 11.3 % RH and 75.3 % RH at +25 C/+77 F; per channel/instrument DAkkS humidity calibration certificate*; humidity probe; calibration points 11.3 % RH and 75.3 % RH at +25 C/+77 F; per channel/instrument *Successor organization of the DKD Alarm module (visual + acoustic), can be connected to base alarm relay 3 Saveris protective housing 20
21 We measure it. testo Saveris set All components can be assembled individually by you. However, you also have the option of ordering a testo Saveris set. This can be supplemented with further components as required. Set: 868 MHz, consisting of base , 3 NTC radio probes without display , mains unit for base and SBE software incl. USB cable Set / 2.4 GHz Adjustment All testo Saveris probes are of course adjusted in the factory, as confirmed by an adjustment report. You can perform further calibrations or adjustments either yourself on site, via a service provider or in a calibration laboratory. The separate Saveris adjustment software is available for this. After successful adjustment, the current adjustment data is stored in the probe. At the same time, the adjustment software and the Saveris software accept this data so that the adjustment histories are available. Radio and Ethernet probes are connected to a cable via the service interface for adjustment. If you do not wish to perform your own calibration, Testo is available as a service provider. Saveris adjustment software incl. connection cable to wireless and Ethernet probes
22 Saveris Service Testo is a manufacturer of measuring instruments and measuring systems with a global presence, with 27 international subsidiaries and representatives in numerous countries. Naturally, testo also offers you onsite service. For questions regarding testo Saveris TM, from installation to retrofitting further system components, please refer to your competent contact in your country. You can find an overview of the nearest service location at 22
23 We measure it. 23
24 Saveris We measure it /msp/Si/Q/ Subject to change without notice.
Measurement data monitoring system
We measure it. Measurement data monitoring system testo Saveris Automated and uninterrupted measurement data recording Flexible system set-up with wireless or Ethernet probes in many probe versions C %RH
More informationMeasurement data monitoring system
Data sheet testo Saveris Measurement data monitoring system testo Saveris Automated and uninterrupted measurement data recording Flexible system set-up with wireless or Ethernet probes in many probe versions
More informationMeasurement data monitoring system
We measure it. Measurement data monitoring system testo Saveris Automated and uninterrupted measurement data recording C Stationary and mobile data monitoring in one system Flexible system set-up with
More informationMeasurement data monitoring system
Data sheet testo Saveris Measurement data monitoring system testo Saveris Automated and uninterrupted measurement data recording Stationary and mobile data monitoring in one system Flexible system set-up
More informationMeasurement data monitoring system
We measure it. Measurement data monitoring system testo Saveris Automated and uninterrupted measurement data recording C Stationary and mobile data monitoring in one system Flexible system set-up with
More informationWe measure it. Automated and uninterrupted measurement data recording. Flexible system set-up with wireless or Ethernet probes in many probe versions
We measure it. Measurement data monitoring system testo Saveris Automated and uninterrupted measurement data recording Flexible system set-up with wireless or Ethernet probes in many probe versions C %RH
More informationMeasurement data monitoring system testo Saveris.
Measurement data monitoring system testo Saveris. Automated and uninterrupted measurement data recording with comprehensive alarm management. testo Saveris testo Saveris: Easy, secure and efficient measurement
More informationMeasure, document, issue alarms. Automated with testo Saveris. Committing to the future
Measure, document, issue alarms. Automated with testo Saveris. Committing to the future testo Saveris : Simple, secure and efficient measurement data monitoring The testo Saveris measurement system measures
More informationMeasurement data monitoring system testo Saveris.
Measurement data monitoring system testo Saveris. Automated and uninterrupted measurement data recording with comprehensive alarm management. testo Saveris testo Saveris: Easy, secure and efficient measurement
More informationMeasurement data monitoring system testo Saveris.
Measurement data monitoring system testo Saveris. Automated and uninterrupted measurement data recording with comprehensive alarm management. Saveris testo Saveris: Easy, secure and efficient measurement
More informationWiFi data logger system
WiFi data logger system Saveris 2 temperature and humidity monitoring re-thought Data transfer by WiFi All measurement data always available, anywhere, on any instrument C %RH Alarms when limit values
More informationWiFi data logger system
Data sheet Saveris 2 WiFi data logger system Saveris 2 temperature, humidity and CO 2 monitoring re-thought C Data transfer by wireless LAN All measurement data always available, anywhere, on any instrument
More informationWiFi data logger system
WiFi data logger system Saveris 2 temperature and humidity monitoring re-thought Data transfer by wireless LAN All measurement data always available, anywhere, on any instrument Alarms when limit values
More informationNext Generation! We measure it. With the professional Testo data loggers, a new age begins for you. Logger series testo 174. Logger series testo 175
We measure it. Next Generation! With the professional Testo data loggers, a new age begins for you Logger series testo 174 Logger series testo 175 Logger series testo 176 testo 174, testo 175, testo 176
More informationAll measurement data. Always available. On any device. The WiFi data logger system testo Saveris 2. Analysis & Reports. Graphical presentation
Analysis & Reports Coldstore east 17.02.2015 to 19.02.2015 Graphical presentation 17/02/2015 18/09/2014 19/09/2014 Data logger 1 ( C) Data logger 2 ( C) Data logger 3 ( C) Tabular presentation Alarms All
More informationNext Generation! Committing to the future. With the professional Testo data loggers, a new age begins for you. Logger series testo 174
Committing to the future Next Generation! With the professional Testo data loggers, a new age begins for you Logger series testo 174 Logger series testo 175 Logger series testo 176 The new generation of
More informationNext Generation! We measure it. With the professional Testo data loggers, a new age begins for you. Logger series testo 174. Logger series testo 175
We measure it. Next Generation! With the professional Testo data loggers, a new age begins for you Logger series testo 174 Logger series testo 175 Logger series testo 176 We measure it. The right logger
More informationMiles Ahead of the Competition!
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com We measure it. Miles Ahead of the Competition! testo data loggers 174, 175 & 176
More informationMeasurement Solutions for Climate Applications in Industry
Committing to the future II/2009 Measurement Solutions for Climate Applications in Industry 2 Measurement Solutions for Climate Applications in Industry Measuring tasks in industry place a variety of complex
More informationF %RH. %rf CO 2. g/m 3. inch H₂O. hpa. Measure. Record. Monitor. Choose the right data loggers for your application now.
F %RH g C %rf CO 2 g/m 3 hpa inch H₂O td Measure. Record. Monitor. Choose the right for your application now. 1 You know your requirements - we have the right. How do you want to record your measurement?
More informationVAC analysis measuring instrument
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com VAC analysis measuring instrument testo 480 Cutting-edge technology for professionals
More informationInfrared temperature measuring instrument
Infrared temperature measuring instrument testo 845 The infrared thermometer with switch optics Non-contact measurement of surface temperature with reference accuracy ±0.75 C and fast measurement technology
More informationThe industrial humidity transmitter
The industrial humidity transmitter + probe series testo 661x Optimum adjustment concept thanks to adjustability of the entire signal chain incl. analog adjustment Ethernet, relay and analog outputs allow
More informationHumidity transmitter for critical climate applications
Humidity transmitter for critical climate applications testo 6651 Optimum adjustment concept thanks to adjustability of the entire signal chain incl. analog adjustment Ethernet, relay and analog outputs
More informationInfrared temperature measuring instrument
Infrared temperature measuring instrument testo 830 Fast, non-contact measurement of surface temperature Laser measurement point marker and large optics for exact measurement even at greater distances
More informationInfrared temperature measuring instrument
Infrared temperature measuring instrument testo 830 Fast, non-contact measurement of surface temperature Laser measurement point marker and large optics for exact measurement even at greater distances
More informationLog, Save, Print and Analyse Data On-Site Quickly and Efficiently
testo 175 / 177 Log, Save, Print and Analyse Data On-Site Quickly and Efficiently %RH td ma/v 2 Simply. More. Time. Time saving, highly flexible data handling on-site The new testo 175 data logger series
More informationThe industrial humidity transmitter
The industrial humidity transmitter + probe series testo 661x Optimum adjustment concept thanks to adjustment of the entire signal chain incl. analog adjustment Profibus, Ethernet, relay and analog outputs
More informationDifferential pressure
Differential pressure measuring instrument 521 Precise Pitot tube measurement Temperature-compensated differential pressure sensor in instrument Additional 2 probe inputs for the connection of further
More informationDifferential pressure measuring instrument
Differential pressure measuring instrument testo 526 Pressure measurement for all pressure ranges Temperature-compensated differential pressure sensor 0 to 2000 in instrument Additional 2 probe inputs
More informationtestostor 171 Instruction manual
testostor 171 Instruction manual en Contents Important information...4 Description...5 Connection instructions...7 Technical data...8 Requirements...12 Making backup copies...12 On the job... Installation...12
More informationDifferential pressure measuring instrument
Differential pressure measuring instrument testo 526 Pressure measurement for all pressure ranges Temperature-compensated differential pressure sensor 0 to 2000 in instrument Additional 2 probe inputs
More informationtesto 735 Compact Pro Series NEW! The working standard for temperature measurements
testo 735 Compact Pro Series NEW! The working standard for temperature measurements F An incredible six channels of temperature measurement The industry leading testo 735 provides two channels for thermocouples,
More informationDifferential pressure measuring instrument
Data sheet testo 526 Differential pressure measuring instrument testo 526 Pressure measurement for all pressure ranges Temperature-compensated differential pressure sensor 0 to 2000 in instrument Additional
More informationInfrared Temperature Measuring Instrument
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Infrared Temperature Measuring Instrument testo 830 Laser measurement point marker
More informationtesto Probe series testo 661x The industrial humidity transmitter We measure it. SPECIFICATIONS testo Probe series testo 661x
+ Probe series testo 661x SPECIFICATIONS Optimum adjustment concept thanks to adjustment of the entire signal chain incl. analog adjustment Profibus, Ethernet, relay and analog outputs allow optimum integration
More informationDifferential pressure measuring instrument
Data sheet testo 521 Differential pressure measuring instrument testo 521 Precise Pitot tube measurement Temperature-compensated differential pressure sensor in instrument Additional 2 probe inputs for
More informationtesto 175 Data loggers Instruction manual
testo 175 Data loggers Instruction manual 2 1 Contents 1 Contents 1 Contents 3 2 Safety and the environment 4 2.1. About this document 4 2.2. Ensure safety 5 2.3. Protecting the environment 5 3 Specifications
More informationRMS WIRELESS MINI LOGGER
RMS WIRELESS MINI LOGGER COMPACT, VERSATILE & FLEXIBLE Various models to measure and log humidity, temperature, lux and electrical values Stores up to 10 000 values Fail safe, due to internal battery and
More informationDifferential pressure measuring instrument
Differential pressure measuring instrument testo 510 Pocket-sized differential pressure measurement Differential pressure measurement 0 to 100 Flow velocity measurement possible with Pitot tube Temperature
More informationEBI 3x0 USB Data Loggers
60 Cold Chain and Process Monitoring EBI 3x0 USB Data Loggers EBI 3x0 USB Data Loggers Cold Chain Monitoring The easy to use data loggers with USB connection monitor the and/or humidity during transport
More informationEBI 3x0 USB Data Loggers
70 Cold Chain and Process Monitoring EBI 3x0 USB Data Loggers EBI 3x0 USB Data Loggers Cold Chain Monitoring The easy to use data loggers with USB connection monitor the and/or humidity during transport
More informationtesto 176 Data loggers
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com testo 176 Data loggers Instruction manual 1 Contents 1 Contents 1 Contents...31
More informationEBI 3x0 USB Data Loggers
70 EBI 3x0 USB Data Loggers Cold Chain Monitoring The easy to use data loggers with USB connection monitor the and/or humidity during transport and storage of sensitive goods like medicine, food, serums
More informationEBI 25 Wireless Data Logger System
62 EBI 25 Wireless Data Logger System The EBI 25 system for wireless monitoring of temperature, humidity and other measurements assures that perishable goods are produced and stored at the right conditions
More informationEBI 3x0 USB Data Loggers
60 EBI 3x0 USB Data Loggers Cold Chain Monitoring The easy to use data loggers with USB connection monitor the and/or humidity during transport and storage of sensitive goods like medicine, food, serums
More informationDATA LOGGERS Reliable solutions for monitoring your processes
www.sauermann.us DATA LOGGERS Reliable solutions for monitoring your processes Sauermann Data Loggers Innovation, Versatility, & Value Sauermann offers a comprehensive range of data loggers that cover
More informationData logger systems from ROTRONIC
Data logger systems from ROTRONIC RS-485 Logger, power supply via RS-485 network RS-485 Logger, power supply via RS-485 network RS-485 Logger, power supply via RS-485 network Logger with power supply RS-485
More informationMeasuring Instruments for Humidity
Committing to the future 2011 Measuring Instruments for Humidity %RH C C td hpa rpm aw CO 2 CO ma V Information Different measuring methods Requirements Gas or air humidity measurements are becoming more
More informationTEMPERATURE HUMIDITY PRESSURE ALL FOR YOUR WIRELESS MEASUREMENT AND DATA COLLECTION FROM ONE PROVIDER!
kiro solo CERTIFICATIONS Certificate DIN EN ISO 9001 : 2015 ESD-Certificate DIN EN 61340-5-1 TEMPERATURE HUMIDITY PRESSURE ALL FOR YOUR WIRELESS MEASUREMENT AND DATA COLLECTION FROM ONE PROVIDER! KIRO
More informationRMS Mini Wireless Data Logger
RMS Mini Wireless Data Logger 2016 ROTRONIC AG Bassersdorf Switzerland Table of Contents 1 Overview... 3 1.1 RMS System Overview... 3 1.2 Device Overview... 4 1.3 RMS Mini Data Logger... 5 1.4 Power Supply...
More informationx testo 400 The reference measuring instrument for A/C and ventilation systems Additional information at
The reference measuring instrument for A/C and ventilation systems Precision reference class measuring instruments have everything the professional user needs to complete complicated measurement tasks
More informationtesto 176 Datenlogger testo 176 Data loggers testo 176 Enregistreur de données Bedienungsanleitung Instruction manual Mode d'emploi
testo 176 Datenlogger Bedienungsanleitung testo 176 Data loggers Instruction manual testo 176 Enregistreur de données Mode d'emploi 1 Contents 1 Contents 1 Contents...31 2 Safety and the environment...32
More informationPI 500 Hand-held instrument for industry
PI 500 Hand-held instrument for industry The new PI 500 is an all-purpose hand-held measuring instrument for many applications in industry like e. g.: Flow measurement Pressure/vacuum measurement Temperature
More informationtesto 175 Instruction manual
testo 175 Instruction manual en Copyright All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical,
More informationDataNet Solution. Wireless intelligent logging network. Sense it. Manage it. H E
H.01.300-E-180626 www.tempco.be Sense it. Manage it. www.fourtec.com DataNet is an essential hardware and software solution that can empower any organization to monitor their environment using the ZigBee
More informationCLEAN ROOM PANEL - CRP5
RELIABLE MEASUREMENTS IN CLEAN ROOMS Measures differential pressure, humidity and temperature Designed specifically for clean rooms Removable humidity and temperature probes for simpler adjustment and
More informationRMS Mini Wireless Data Logger
2018 ROTRONIC AG Bassersdorf Switzerland Table of Contents 1 Overview... 3 1.1 RMS System Overview... 3 1.2 Device Overview... 4 1.3 RMS Mini Data Logger... 5 1.4 Power Supply... 5 1.5 Measured Parameters...
More informationThe flue gas analyzer with Longlife sensors and integrated draught/gas zeroing
The flue gas analyzer with Longlife sensors and integrated draught/gas zeroing testo 330-2 LL The flue gas analyser is a reliable companion regardless of whether it is for breakdowns or emergencies, monitoring
More informationPrecision Hand-held Thermometer
Precision Hand-held Thermometer measuring monitoring analysing Measuring range from -220 C... +1768 C Measuring accuracy starting with ±0.03% MV Large selection of temperature probes PT 100 or thermocouple
More informationMulti-functional precision thermometer CTR3000
Calibration technology Multi-functional precision thermometer CTR3000 WIKA data sheet CT 60.15 Applications Pharmaceutical industry Industry (laboratory, workshop and production) Temperature sensor and
More informationtesto LL Flue gas analysis with increased convenience and reliabilty
10 testo 330-1 LL Flue gas analysis with increased convenience and reliabilty You are looking at the technical edge. The extended service life of the sensors in testo 330-1 LL by up to 6 years for O 2
More informationLight intensity measuring instrument
We measure it. Light intensity measuring instrument testo 540 Pocket-sized Lux meter Sensor adapted to spectral sensitivity of the eye Lux Hold-function and max./min. values Display illumination Illustration
More informationtesto Probe series testo 661x The industrial humidity transmitter Committing to the future
Committing to the future + Probe series testo 661x SPECIFICATIONS Optimum adjustment concept thanks to adjustment of the entire signal chain incl. analog adjustment Profibus, Ethernet, relay and analog
More informationtesto 875 and testo 881 for professional building thermography
26 testo 875 and testo 881 for professional building thermography The testo 875 and testo 881 thermal imagers carry out fast and efficient tests on heating and air conditioning/ventilation systems. testo
More informationData Logging Solutions from Lascar Electronics
Data Logging Solutions from Lascar Electronics Remote Monitoring EL-BT-2 Bluetooth and Humidity Data Logging The EL-BT-2 data logger measures and stores over 1 million temperature and humidity readings.
More informationAvoid experiments in monitoring important parameters. Measuring instruments and solutions for the pharmaceutical, medical and healthcare industries
Avoid experiments in monitoring important parameters Measuring instruments and solutions for the pharmaceutical, medical and healthcare industries ABOUT ROTRONIC Swiss precision at the highest level Founded
More informationEE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310
is optimized for reliable measurement in demanding industrial applications. In addition to highly accurate measurement of relative humidity (RH) and temperature (T), the transmitter also calculates parameters
More informationTemperature Data Logger EBI 100
54 Data Logger EBI 100 Type EBI 10-T100 Measuring range -40 C... +150 C (-40 F...+302 F) 0.3 C (0.9 F) of +40 C... +150 C (-40 F... +302 F) 0.1 C (0.2 F) Memory 27,000 measured values Operating temperature
More informationHand-Held Thermometer Model CTH 6200
Testing and Calibration Technology Hand-Held Thermometer Model CTH 6200 WIKA Data Sheet CT 51.01 Applications Service industry Measurement and and control laboratories Industry (laboratory, workshop and
More informationEE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310
High-End Humidity and Temperature Transmitter for Demanding Process Control is optimized for reliable measurement in demanding industrial applications. In addition to highly accurate measurement of relative
More informationPRODUCT GUIDE. Your Data, Anytime, Anywhere.
PRODUCT GUIDE Your Data, Anytime, Anywhere www.tempro.be WiFi Sensors For Every Situation FilesThruTheAir offers a comprehensive environmental monitoring package, combining high specification WiFi sensors
More informationDew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410
Dew point set DS 400 for stationary dew point monitoring of refrigeration or adsorption dryers. The touch screen graphic display enables an intuitive operation and shows the progress of the measured values.
More informationCommitting to the future. Measurement Solutions for Production, Quality Control and Maintenance
Committing to the future 2010 Measurement Solutions for Production, Quality Control and Maintenance 2 Measurement Solutions for Production, Quality Control and Maintenance Measuring tasks in industry place
More informationBIOMERIEUX PERFORMANCE SOLUTIONS Quality & Compliance Services. How will Labguard watch over your quality?
BIOMERIEUX PERFORMANCE SOLUTIONS Quality & Compliance Services How will Labguard watch over your quality? Labguard 3D Services EVALUATION l Pre-installation evaluation with our experts to assess the installation
More informationIDS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors
IDS 400 mobile Affordable, mobile chart recorder Energy analysis - ow measurement - leakage calculation at compressed air systems Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party
More information1523/1524. Reference Thermometers. Measure, graph and record three sensor types with one tool
1523/1524 Reference Thermometers Measure, graph and record three sensor types with one tool Finally, a reference thermometer as versatile as you The 1523/24 Reference Thermometers from Fluke Calibration
More informationTRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights
HygroFlex & HygroClip-EX HygroFlex series may be used together with the intrinsically safe HygroClip-EX probes. The relative humidity and temperature can be displayed and output as analog signals. Calculated
More informationDMT345 and DMT346 Dewpoint Transmitters
DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications Features DMT345 measures humidity at temperatures up to 180 C (356 F) DMT346 measures humidity at temperatures up to 350 C (+662
More informationEE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)
is dedicated for reliable monitoring of lubrication, hydraulic and insulation oils as well as diesel fuel. In addition to highly accurate measurement of water activity (a w ) and temperature (T), calculates
More informationClass 220 KISTOCK. KT 220, KH 220 and KTT 220
Class 220 KISTOCK KT 220, KH 220 and KTT 220 Table of contents 1 Safety instructions...4 1.1 Precautions for use...4 1.2 Symbols used...4 2 Presentation of the device...5 2.1 Use...5 2.2 Applications...5
More informationDataSuite User Guide. Supporting: DataNet, DaqLink, MicroLite, MicroLogPRO II, PicoLite. FDA Title 21 CFR Part 11 Compliant.
ourtec FOURIERTECHNOLOGIES FDA Title 21 CFR Part 11 Compliant www.kongsgaarden.no www.fourtec.com www.fourtec.com DataSuite User Guide Supporting: DataNet, DaqLink, MicroLite, MicroLogPRO II, PicoLite
More informationtesto 6740 Instruction manual
testo 6740 Instruction manual en Preface 3 Preface Preface Dear Testo Customer Congratulations for choosing a Testo product. We hope that you will enjoy many years of using the product and that it will
More informationKISTOCK DATALOGGER KT 320 / KTT 320
KISTOCK DATALOGGER KT 30 / KTT 30 / Humidity / Voltage/ Current / Impulsion KEY POINTS Software for configuration and data visualisation freely downloadable Software for configuration and data processing
More informationtesto 184 Data logger Instruction manual
testo 184 Data logger Instruction manual 2 1 Safety and the environment 1 Safety and the environment 1.1. About this document Use > Please read this documentation through carefully and familiarize yourself
More informationMeasuring Instruments for Humidity
Measuring Instruments for Humidity Info Requirements Gas or air humidity measurements are becoming more and more important. Constant improvements to the technical processes, higher demands on quality and
More informationPTU300 Combined Pressure, Humidity and Temperature Transmitter
PTU300 Combined Pressure, Humidity and Temperature Transmitter For Demanding Applications Features Barometric pressure, humidity, and temperature measurement in one transmitter RS-232C serial interface
More informationChart recorder. DS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors
DS 400 mobile Affordable, mobile chart recorder Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party s Internal rechargeable Li-Ion batteries, approx. 8 h continous operation Easy
More informationJUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet
sales@jumo.co.uk info.us@jumo.net Page 1/9 JUMO PINOS L01 Calorimetric flow sensor Brief description The JUMO PINOS L01 flow sensor serves the measuring and monitoring of flow velocities of water and aqueous
More informationTechnical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291
TI01198C/07/EN/02.15 71288268 Products Solutions Services Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291 Portable multiparameter device for Memosens ph, conductivity and oxygen
More informationRefrigerated incubators with forced convection
KB series (E3.1) Incubators Refrigerated incubators with forced convection The most versatile incubator for microorganisms: The BINDER KB series controls a temperature range of -5 C to 100 C. With its
More informationDatasheet Thermal imager
Datasheet Thermal imager 875 the entry into professional thermography Detector size pixels C SuperResolution technology to 320 x 240 pixels Thermal sensitivity 50 mk Built-in digital camera with power
More informationMulti-Function Measuring Instruments
Committing to the future 2011 Multi-Function Measuring Instruments C %RH m/s hpa CO 2 Lux CO aw rpm ma V Information Measurement Engineering For Multi-Function Measuring Instruments Measurement and application
More informationSpecification for temperature sensor calibration setup
1. Item description Automated Temperature calibration setup made of: A. High accuracy temperature bath with internal and external reference probe, multiple sensors insert kits, carry case and other accessories.
More informationHLX31 Series. Multifunctional Industrial Transmitter for Humidity / Temperature / Dew Point / Absolute Humidity... Model A. Model B.
Series The precise and reliable measurement of humidity in industrial processes is gaining more and more importance. The multifunctional transmitters series offer the ideal solution. The result of many
More informationStandard Operating Procedure for the Kaye Validator AVS System
Document #: Revision: A Kaye Validator AVS Standard Operating Version 1.0 This is a version controlled document that is released with Amphenol internal approvals. The Approvals section is provided for
More informationHand-held thermometer Model CTH7000
Calibration technology Hand-held thermometer Model CTH7000 WIKA data sheet CT 55.50 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference
More informationCompressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture
Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture Residual oil content measurement OIL-Check 400 For permanent and highly precise measurement of the vaporous
More informationInput for universal probe* Inputs for thermocouple probes
Device reference Display Internal sensor External sensor Number Type Number Type Parameters Number of record points KT 220 - O KT 220 - N KH 220 - O KH 220 - N Yes No Yes No 1 Temperature 3 Temperature,
More informationJUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature
Page 1/7 JUMO ecotrans 03 Microprocessor transmitter/ switching device for /Redox voltage and temperature with a 2-line LCD for mounting on a 35 mm DIN rail Brief description Depending on the configuration,
More information