MOTOR PROTECTION CIRCUIT BREAKERS
|
|
- June Poole
- 5 years ago
- Views:
Transcription
1 MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm depth. SMB Thermal trip adjustment ranges 0.-32A (5 choices) Breaking capacity Icu at 400V: 00kA (ranges 0.-0A) 25kA (ranges 9-32A) Suitable for mounting in consumer switchboards with minimum 58mm depth. Wide adjustment range 0. to 00A Breaking capacity Icu 50kA (400V) up to 00A Suitable for isolation Comprehensive line of accessories Front mount contacts Automatic trip indicators High reliability and accuracy of tripping. PLANET -SWITCH SEC. PAGE Breakers SMA, SMB and SMC Breakers SM2A and SM3A Add-on blocks and accessories for SMA, SMB and SMC Add-on blocks and accessories for SM2A and SM3A Starters LMS Add-on blocks and accessories for LMS PAGE -2 PAGE -3 SMC Same characteristics per SMB breaker Suitable for mounting in consumer switchboards with minimum 45mm depth. SM2A Thermal trip adjustment ranges 28-50A (3 choices) Breaking capacity Icu at 400V: 50kA. Short-circuit tripping indicator, standard supplied on all circuit breakers, type SM. Reset the indicator, as illustrated, to restore the breaker. PAGE -3 PAGE -0 SM3A Thermal trip adjustment ranges 45-00A (4 choices) Breaking capacity Icu at 400V: 50kA. LMS25 Thermal trip adjustment ranges 0.-25A (3 choices) Breaking capacity Icu at 400V: 00kA (ranges A) 6kA (ranges 6.3-0A) 4kA (ranges 0-25A) Suitable for mounting in consumer switchboards with minimum 45mm depth.
2 L -2 With thermal and magnetic trip releases Motor protection circuit breakers SM up to 32A SMA... SMB... SMC... Order Thermal Short circuit Qty Wt code trip breaking per adjustment capacity pkg range at 400V Icu Ics [A] [ka] [ka] n [kg] Breaking capacity Icu 50kA at 400V. SMA SMA SMA SMA SMA Breaking capacity Icu 00kA (0.-0A) / 25kA (9-32A) at 400V. SMB SMB SMB SMB SMB SMB SMB SMB SMB SMB SMB SMB SMB SMB SMB Breaking capacity Icu 00kA (0.-0A) / 25kA (9-32A) at 400V. Suitable for mounting in modular consumer switchboards ❶. SMC 00❶ SMC 04❶ SMC 08❶ SMC 2❶ SMC 6❶ SMC 20❶ SMC 24❶ SMC 28❶ SMC 32❶ SMC 36❶ SMC 40❶ SMC 44❶ SMC 48❶ SMC 52❶ SMC 56❶ ❶ The SMC version consents to the mounting in enclosures and modular consumer switchboards with minimum depth of at least 45mm between the DIN rail and the opening. See page D-2 for exact breaker dimensions. No front-mount auxiliary contacts SMX... can be used. General characteristics The SM is a modern series of circuit breakers with thermal and magnetic trip releases and high breaking capacity. Motor control and protection, up to 5kW at 400V, are possible by choosing the suitable adjustment range, 0. to 32A. A magnetic trip indicator integrated on the SM breakers avoids dangerous closing operations during short-circuit conditions, previously disconnected by the breaker. The SM types are suitable for isolation according to IEC/EN standards. Their high breaking capacity consents to exclude protection fuses on the majority of the installations. Operational characteristics Rated insulation voltage Ui: 690V Rated impulse withstand voltage: 6kV Rated frequency: 50/60Hz Maximum rated current: 32A Number of adjustment ranges: SMA: 5 (9 to 32A) SMB: 5 (0. to 32A) SMC: 5 (0. to 32A) Breaking capacity: see table below Power dissipation: W Magnetic tripping: 2In max Thermal tripping class: 0A Phase failure sensitive Mechanical life: 00,000 cycles Electrical life: 00,000 cycles Mounting on 35mm DIN rail (IEC/EN 6075) Mounting position: Any Utilisation category: A Degree of protection: IP20. Certifications obtained: culus; GOST and CCC for SMB type only. Compliant with standards: IEC/EN , IEC/EN , IEC/EN max Nm NOTE: When more than one breaker are mounted, side by side, without leaving space between each to consent free air circulation on the breaker sides, and have simultaneous operation, the thermal trip adjuster must be positioned at a value 5% higher than the rated motor current. ovato max 2.3 Nm max Nm Lovato Breaking capacity Type Rated short-circuit breaking capacity [ka] Protection fuses when I > Icu (gl or gg fuses) ❷ 230V 400V 500V 690V 230V 400V 500V 690V Icu Ics Icu Ics Icu Ics Icu Ics [A] [A] [A] [A] SMA SMA SMB SMC SMB SMC SMB 32 / SMC SMB 36 / SMC SMB 40 / SMC SMB SMC ❷ Fuses are used only in those cases when the value of short-circuit current at the breaker installation point exceeds the breaking capacity of the breaker. Fuse not required. Add-on blocks/accessories pages -4 to 7 page D-2
3 With thermal and magnetic trip releases -3 Motor protection circuit breakers SM2A - SM3A up to 00A SM2A... Order Short circuit Short circuit Qty Wt code thermal breaking per trip capacity pkg adjustment at 400V range Icu Ics [A] [ka] [ka] n [kg] Breaking capacity Icu 50kA at 400V. SM2A SM2A SM2A Breaking capacity Icu 50kA at 400V. SM3A SM3A SM3A SM3A General characteristics The SM2A and SM3A types are circuit breakers with a wide adjustment range, 28 to 00A, in only two frame sizes enabling motor control and protection up to 45kW (400V). A magnetic trip indicator and padlockable operating handle are integrated on the SM2A and SM3A breakers. Both are suitable for isolation according to IEC/EN standards. Their high breaking capacity consents to exclude protection fuses on the majority of the installations. Operational characteristics Rated insulation voltage Ui: 690V Rated impulse withstand voltage: 6kV Rated frequency: 50/60Hz Maximum rated current: 50A (SM2A) and 00A (SM3A) Number of adjustment ranges: SM2A: 3 (28 to 50A) SM3A: 4 (45 to 00A) Breaking capacity: See table below Power dissipation: SM2A: 7.-20W SM3A: 0-38W Magnetic tripping: 3In max Thermal tripping class: 0 Phase failure sensitive Life (cycles): Mechanical Electrical (Ie AC3) SM2A 50,000 25,000 SM3A 50,000 25,000 Mounting: SM2A - Screw fixing or on 35mm DIN rail (IEC/EN 6075) SM3A - Screw fixing or on DIN rail 35mm (IEC/EN 6075) or 75mm (IEC/EN 6075) Mounting position: Any Utilisation category: A Degree of protection: IP00. Certifications obtained: GOST; culus, CSA. Compliant with standards: IEC/EN , IEC/EN , IEC/EN SM3A... NOTE: When more than one breaker are mounted, side by side, without leaving space between each to consent free air circulation on the breaker sides, and have simultaneous operation, the thermal trip adjuster must be positioned at a value 5% greater than the rated motor current. Breaking capacity Type Rated short-circuit breaking capacity [ka] Protection fuses when I > Icu (gl or gg fuses) ❶ 230V 400V 500V 690V 230V 400V 500V 690V Icu Ics Icu Ics Icu Ics Icu Ics [A] [A] [A] [A] SM2A 68 / SM2A SM2A SM3A SM3A SM3A 92 / SM3A ❶ Fuses are used only in those cases when the value of short-circuit current at the breaker installation point exceeds the breaking capacity of the breaker. Fuse not required. Add-on blocks/accessories pages -8 and 9 page D-3
4 -4 Add-on blocks and accessories for SM types Add-on blocks and accessories SMX... SMX2... SMX3 SMX5... SMX6... SMX8 0 SMX SMX SMX4... SMX90 30 SMX90 3 Order code Characteristics Qty Wt per pkg n [kg] Add-on auxiliary contacts. SMX 20❶ Front mount 2NO SMX ❶ Front mount NO+NC SMX2 Side mount NO+NC SMX2 02 Side mount 2NC SMX2 20 Side mount 2NO SMX3 Side-mount indicator contacts for thermal and magnetic tripping NO+NC❷ Undervoltage trip releases. SMX4 BC 0VAC 50/60Hz SMX4 CL 230VAC 50/60Hz SMX4 EA 400VAC 50/60Hz SMX5 CL 230VAC 50/60Hz with early-make contacts SMX5 EA 400VAC 50/60Hz with early-make contacts Shunt trip releases. SMX6 AF 24VAC 50/60Hz SMX6 BC 0VAC 50/60Hz SMX6 CL 230VAC 50/60Hz SMX6 EA 400VAC 50/60Hz Padlockable attachment for operating lever. SMX8 0 3 padlocks max Ø 5mm 0.02 Adjuster sealing kit. SMX8 2 For all types Padlockable door coupling handle. SMX8 4 3 padlocks maximum IP65. Yellow/red colour SMX8 5 3 padlocks maximum 0.70 IP65. Black colour Terminal block for busbar supply. SMX90 30 For all types Safety cover. SMX90 3 For unused busbar terminals Three-phase connection busbars 45mm spacing. SMX90 32 For 2 breakers without SMX90 33 For 3 breakers without SMX90 34 For 4 breakers without SMX90 35 For 5 breakers without Three-phase connection busbars 54mm spacing. SMX90 42 For 2 breakers complete with SMX90 43 For 3 breakers complete with SMX90 44 For 4 breakers complete with SMX90 45 For 5 breakers complete with ❶ Not suitable for fixing on SMC types. ❷ Tripping is indicated by flag indicator on front. General and operational characteristics ADD-ON AUXILIARY BLOCKS Snap on to the front or the right side of the breaker Maximum combination: 6 auxiliary contacts of which 2 on front (SMC excluded) and 4 on the side (2 normal contacts and 2 indicators) Conventional free air thermal current Ith: 6A (2.5A for SMX...) Rated insulation voltage Ui: 690V (250V for SMX...) Designation according to IEC/EN : C600 Q600 (C300 R300 for SMX...) ( or 2 wires): mm 2 or 8/4 AWG Width of side-mount auxiliary contacts equal to 0.5 standard DIN module. UNDERVOLTAGE TRIP RELEASE Connectable to the left side of the breaker Consumption in-rush/holding: 2/3.5VA Drop-out voltage: Us Pick-up voltage: Us ( or 2 wires): mm 2 or 8/4 AWG. SHUNT TRIP RELEASE Connectable to the left side of the breaker In-rush consumption: 20VA Operating limits: 0.7-.Us ( or 2 wires): mm 2 or 8/4 AWG. THREE-PHASE CONNECTION BUSBAR Imax 63A SMX mm spacing to reduce the width to the minimum SMX mm spacing to consent to fit one side-mount auxiliary contact block on the breaker connectable to terminal block for busbar supply: 4-25mm 2 or 0/4 AWG. TERMINAL BLOCK FOR BUSBAR SUPPLY Imax 63A : 4-25mm 2 or 0/4 AWG. Certifications obtained: GOST; culus for auxiliary contacts, releases and padlockable attachment for operating lever; CCC for SMX2... and SMX3 auxiliary contacts. Compliant with standards: IEC/EN , IEC/EN page D-2 and 3
5 Add-on blocks and accessories for SM types -5 SMX90 03 SMX7 0 SMX7 SMX7 35 SMX3 4 SMX3 42 SMX32 4 SMX90 0 SMX90 2 SMX90 4 SMX7 20 SMX7 40 Order code Characteristics Qty Wt per pkg n [kg] Rigid SM breaker-contactor connections. SMX90 03 For SM breaker with BG mini-contactor. SMX3 4 For SM breaker with BF09A-BF25A contactor. Complete with cover SMX3 42 For SM breaker with BF9D-BF25D and BF9L-BF25L contactor. Complete with cover SMX32 4 For SM breaker with BF26A-BF38A contactor. Complete with cover Adapter plates. SMX90 0 Adapter plate for direct-on-line starter (SM breaker and BG or BF09A-BF38A contactors) SMX90 2 Adapter plate for reversing contactor assembly (SM breaker and BG or BF09A-BF38A contactors) SMX90 4 Adapter plate for star-delta 0.04 starter (SM breaker and 45mm wide contactors BF09A-BF38A) SMX mm DIN rail (IEC/EN 6075) for cable bypass of contactor used with SMX90 4 plate SMX mm DIN rail extension for mm wide contactors Surface mount enclosures. SMX7 0 IP40. 00mm wide SMX7 ❶ IP40. 85mm wide Flush mount enclosure. SMX7 20 IP40. 02mm wide ACCESSORIES FOR ENCLOSURES. Padlockable rotary actuator. SMX7 30❷ IP65. Grey/black colour. 0.0 For SMX7 0 and SMX7 20 enclosures SMX7 35❷ IP65. Red-yellow colour. 0.0 For SMX7 0 and SMX7 20 enclosures Actuator with emergency stop button. SMX7 40❷ IP65. For SMX enclosure IP65 membrane complete with rim. SMX7 45 For SMX7 enclosure Neutral connection. SMX7 50 For SMX7 0 and SMX7 20 enclosures only Pilot light. 23 NEONV❸V Green NEONR❸V Red Marking elements. BFX30 Blank label for writing ❶ To obtain IP65 degree of protection, mount the SMX7 45 membrane. ❷ The device obtained with this actuator is not suitable for isolation per IEC/EN standards. ❸ Complete with required voltage. Available voltages: 24 / 0 / 220 / 380VAC. General and operational characteristics SM - CONTACTOR CONNECTION The SMX90 03, SMX3 4 and SMX32 4 rigid connections ally and mechanically fasten the breaker together with the contactor forming a single-unit starter for quick installation on 35mm DIN rail (IEC/EN 6075). STARTER ASSEMBLY ADAPTER PLATES The elements consent to preassemble starters and to form trim and compact single-unit equipment for quick and easy installation. The starter adapter plates install on 35mm DIN rail (IEC/EN 6075). SURFACE MOUNT ENCLOSURE Top or bottom entry: PG6 threaded knockouts for SMX mm knockouts for SMX7 Rear entry: 22.5mm knockouts Holds a SM breaker equipped with one side-mount contact block, one front-mount block (except for SMC) and either one shunt or undervoltage release Earth terminal included Operating temperature: C Storage temperature: C. FLUSH MOUNT ENCLOSURE Use with breaker, complete with front-mount (except for SMC) and side-mount blocks and one shunt or undervoltage release Earth terminal included 02x42.8mm cutout Operating temperature: C Storage temperature: C. ENCLOSURE ACCESSORIES PADLOCKABLE ROTARY ACTUATOR: Suitable for SMX7 0 or SMX7 20 type only Raises the degree of protection of the enclosure to IP65 3 padlocks maximum. ACTUATOR WITH EMERGENCY PUSH-BUTTON: Suitable for SMX7 only Raises the degree of protection of the enclosure to IP65. Certifications obtained: GOST; culus for SMX90 03, SMX3 4 and SMX32 4 connections. Compliant with standards: IEC/EN SMX7 45 page D-2 and 3
6 -6 Add-on blocks and accessories for SM types Combinations Front-mount contacts. Side-mount contacts. Undervoltage trip release. Shunt trip release. Side-mount contacts. Undervoltage trip release with auxiliary contacts. SMX4...❷ SMX6...❷ SMX5 SMX3❸ SMX2...❸ SMX3❸ SMX2...❸ SMX...❶ ❶ Not suitable for use with SMC type. ❷ Only one add-on block can be fixed on the left side of the breaker. ❸ One of the following combinations can be mounted on the right side of the breaker: One each of SMX3 and SMX2... or one only SMX3 or one only SMX2... Three-phase connection busbars SMX90 30 SMX90 35 SMX90 3 SMX90 34 SMX90 32 SMX90 33 Three-phase connection busbar, 45mm spacing (breakers without add-on blocks). SMX90 45 SMX90 30 SMX90 3 SMX90 44 SMX90 42 SMX90 43 Three-phase connection busbar, 54mm spacing (breakers with add-on blocks). page D-2
7 Add-on blocks and accessories for SM types -7 Combinations Rigid breaker-contactor connection and protection cover SM... SM... SM... SMX3 4 ❶ SMX3 42 ❷ SMX32 4 SMX90 03 BG... BF09-BF25 BF26A-BF38A Padlockable attachment for operating lever Adjuster sealing kit Padlockable door coupling handle SMX8 4 SMX8 5 SMX8 0 SMX8 2 Surface mount enclosure SMX7 0 or SMX7 Surface mount enclosure SMX7 complete with emergency stop button SMX7 40. ❸ SMX2... SMX3 SMX5... SMX... SMX7 40 SMX6... SMX4... Flush mount enclosure SMX7 20 SMX7 ❶ For BF09A-BF25A contactors. ❷ For BF09D-BF25D and BF09L-BF25L contactors. ❸ One only add-on block can be mounted on each side of the breaker. page D-2
8 -8 Add-on blocks and accessories for SM2A and SM3A types Add-on blocks and accessories SMX20 SMX2 SMX22... SMX23 Order code Characteristics Qty Wt per pkg n [kg] Add-on auxiliary contacts. SMX20 Front mount changeover SMX2 Front mount NO+NC SMX22 02 Side mount 2NC SMX22 Side mount NO+NC SMX22 20 Side mount 2NO SMX23 Side-mount indicator contacts (NO+NC) for thermal trip and (NO+NC) for magnetic trip ❶ Undervoltage trip releases. SMX24 BC 0VAC 50/60Hz 0.35 SMX24 CL 230VAC 50/60Hz 0.35 SMX24 EA 400VAC 50/60Hz 0.35 SMX25 CL 230VAC (50/60Hz) 0.35 with early-make contacts SMX25 EA 400VAC (50/60Hz) 0.35 with early-make contacts Shunt trip releases. SMX26 AF 24VAC 50/60Hz 0.35 SMX26 BC 0VAC 50/60Hz 0.35 SMX26 CL 230VAC 50/60Hz 0.35 SMX26 EA 400VAC 50/60Hz 0.35 Padlockable door coupling rotary actuator. SMX28 05 IP65. 3 padlocks maximum Black colour SMX28 0 IP65. 3 padlocks maximum Red/yellow colour ❶ See diagram on p. W-2 for the exact operation. General and operational characteristics ADD-ON AUXILIARY BLOCKS Insert on the top front or snap on the left side of the breaker Maximum combination: 8 auxiliary contacts of which 2 on front and 6 on the sides (2 normal contacts and 4 indicators) Conventional free air thermal current Ith: 0A (2.5A for SMX2 ) Rated insulation voltage Ui: 690V (250V for SMX20... and SMX2...) Designation according to IEC/EN : A600 Q300 (C300 R300 for SMX20... and SMX2...) ( or 2 wires): mm 2 or 8/4 AWG. UNDERVOLTAGE TRIP RELEASE Snap on to the right side of the breaker Consumption inrush/holding: 20.2/7.2 VA; 3/2.4 W Drop-out voltage: Us Pick-up voltage: Us ( or 2 wires): mm 2 or 8/4 AWG. SHUNT TRIP RELEASE Snap on to the right side of the breaker In-rush consumption: 20.2VA; 3W Operating voltage: 0.7-.Us ( or 2 wires): mm 2 or 8/4 AWG. Certifications obtained: GOST; culus and CSA for auxiliary contacts and releases. Compliant with standards: IEC/EN , IEC/EN SMX24... SMX25... SMX26... page D-3
9 Add-on blocks and accessories for SM2A and SM3A types -9 Combinations SMX24... SMX25... SMX26... L Lovato SMX23 SMX22... SMX20 SMX2 Padlockable door coupling rotary actuator SMX SMX28 0 L Lovato max. max 8 Ø 8mm page D-3
10 -0 Manual motor starters Manual motor starter LMS25 up to 25A LMS Order code Thermal Short circuit Qty Wt adjustment breaking per range capacity pkg at 400V Icu Ics [A] [ka] [ka] n [kg] Breaking capacity Icu at 400V: 00kA (0.-6.3A) / 4kA (0-25A) at 400V / 6kA (6.3-0A). LMS25 06T LMS25 025T LMS25 04T LMS25 063T LMS25 T LMS25 V6T LMS25 2V5T LMS25 4T LMS25 6V3T LMS25 0T LMS25 6T LMS25 20T LMS25 25T General characteristics The LMS25 manual motor starter is particularly suitable for controlling small operating machines. Releases and auxiliary contacts make it also suitable for more complex uses. Wall and flush-mount enclosures allow to install the LMS25 starter in the most disparate environmental conditions (dust, humidity, aggressive environmental agents, etc.). Operational characteristics Rated insulation voltage Ui: 690V Rated impulse withstand voltage: 6kV Rated frequency: 50/60Hz Maximum rated current: 25A 3 adjustment ranges 0. to 25A Breaking capacity: see table below Power dissipation: 2-5W Magnetic tripping: 2In max Thermal tripping class: 0 Phase failure sensitive Mechanical life: 00,000 cycles Electrical life 25A (AC3): 00,000 cycles Mounting on 35mm DIN rail (IEC/EN 6075) or screw fixing Mounting position: Any Utilisation category: A Degree of protection: IP20. Certifications obtained: GOST; culus. Compliant with standards: IEC/EN , IEC/EN , IEC/EN Breaking capacity Type Rated short-circuit breaking capacity [ka] Protection fuses when I > Icu (gl or gg fuses) ❶ 230V 400V 500V 690V 230V 400V 500V 690V Icu Ics Icu Ics Icu Ics Icu Ics [A] [A] [A] [A] LMS25 06T / LMS25 025T LMS25 04T / LMS25 063T LMS25 T / LMS25 V6T LMS252V5T LMS25 4T LMS25 6V3T LMS25 0T LMS25 6T LMS25 20T / LMS25 25T ❶ Fuses are used only in those cases when the short-circuit current value at the starter installation point exceeds the breaking capacity of the starter itself. Fuse not required. Add-on blocks/accessories page - page D-3
11 Add-on blocks and accessories for LMS25 types - Add-on blocks and accessories LMH... LMU... - LMA... SMX90 32 SMX90 30 LMZ - LMZ2 LMZ3 - LMZ4 LMZ05 LMZ06 Order code Characteristics Qty Wt per pkg n [kg] Add-on auxiliary contacts. Side mount. LMH 0 NC LMH 0 NO LMH NO + NC LMH 20 2NO Undervoltage trip release. LMU❶ To fit inside starter For all types Shunt trip release. LMA❶ To fit inside starter For all types Terminal block for busbar supply. SMX90 30 For all types Three-phase connection busbars 45mm spacing. SMX90 32 For 2 breakers without SMX90 33 For 3 breakers without SMX90 34 For 4 breakers without SMX90 35 For 5 breakers without Three-phase connection busbars 54mm spacing. SMX90 42 For 2 breakers complete with SMX90 43 For 3 breakers complete with SMX90 44 For 4 breakers complete with SMX90 45 For 5 breakers complete with Surface mount enclosures. LMZ 2 IP54. 80mm wide LMZ IP55. 80mm wide Flush mount enclosures. LMZ 4 IP4. 85mm wide 0.50 LMZ 3 IP55. 85mm wide 0.60 Accessories for enclosures. Locking mechanism. LMZ 05 3 padlocks maximum Emergency stop button. IP55 protection. LMZ 06 For all types Neutral connection. LMN PE For all types Pilot light. 23 NEONV❷V Green NEONR❷V Red Spare IP55 membrane complete with rim for enclosures. LMM For LMZ enclosures M25 to PG6 entry adapter. LM M25 PG6 For LMZ and LMZ2 enclosures ❶ Specify rated voltage. Add suffix 60 if frequency is 60Hz. Available voltages: 24 / 48 / 0 / indicate 220 / indicate 380 / indicate 440 / 480 and 575VAC. ❷ Indicate required voltage value. Available voltages: 24 / 0 / 220 / 380VAC. General and operational characteristics ADD-ON AUXILIARY CONTACTS Connectable to right or left side of starter Maximum combination: 4 auxiliary contacts Rated insulation voltage Ui: 500V Conventional free air thermal current Ith: 6A Operational current AC5: 3.5A 230V; 2A 400V Protection fuse (gl or gg): 6A maximum ( or 2 wires): mm 2 Width of the auxiliary contacts LMH... equal to 0.5 standard DIN43880 modules. UNDERVOLTAGE AND SHUNT TRIP RELEASES Must be fitted inside the motor starter. Undervoltage Shunt Release range Us Operating range Us 0.7-.Us On-load factor 00% THREE-PHASE CONNECTION BUSBAR Imax 63A SMX mm spacing to reduce the width to the minimum SMX mm spacing to consent to fit one sidemount auxiliary contact block on the breaker terminal block for busbar supply: 4-25mm 2 or 0/4 AWG. TERMINAL BLOCK FOR BAR SUPPLY Imax 63A : 4-25mm 2 or 0/4 AWG. SURFACE MOUNT ENCLOSURE Top or bottom entry: M25 threaded knockouts Rear entry: 5.5mm knockouts Up to two auxiliary contact blocks may be mounted Earth terminal included Operating termperature: C Storage termperature: C. FLUSH MOUNT ENCLOSURE Window size 70x5mm Up to two auxiliary contact blocks may be mounted Earth terminal included Operating termperature: C Storage termperature: C. ACCESSORIES FOR ENCLOSURES Locking mechanism: Prevents closing operation; 3 padlocks maximum. Emergency stop button: Turn to release Red push-button Ø 35mm NOTE: Once mounted on the enclosure, these accessories raise the degree of protection from IP4 to IP55. Certifications obtained: GOST; culus for auxiliary contacts and trip releases. Compliant with standards: IEC/EN , IEC/EN LMNPE 23 NEON...V page D-3
Motor protection circuit breakers
Wide adjustment range 0. to 00A IEC breaking capacity Icu 50kA (400V) up to 00A Suitable for isolation Comprehensive line of accessories Magnetic-only version Automatic trip indicators High reliability
More informationMOTOR & CIRCUIT PROTECTION
2 MOTOR & CIRCUIT PROTECTION Motor Protection Circuit Breakers p2-1 Motor Protection Relays p2-13 Thermistor Protection Relay p2-18 Fuse Holders p2-20 Miniature Circuit Breakers p2-23 Residual Current
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More informationIDE Load break switches for machine control Remotely trippable switch from 32 to 160 A
The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct
More informationIMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp
IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5
More informationJ7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1
Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload
More informationCircuit Breakers, Type CTI 25M, CTI 45MB, CTI 100
MAKING MODERN LIVING POSSIBLE Data sheet Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit and overload protection of motor applications cover together with the circuit
More informationApproved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.
Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit
More information63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.
comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power
More informationCircuit Breakers Type CTI 25M, CTI 45MB
Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More information3RV1 Circuit-Breakers
SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a
More informationSWITCH DISCONNECTORS 11
SWITCH DISCONNECTORS 16A to 1600A ratings Versions: direct operating handle, door coupling and in housing Wide range of accessories Types for photovoltaic applications up to 850A 1000VDC in DC21B duty
More informationOVERLOAD RELAYS POWER & ACTUATION PROVEN. series
POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be
More informationSwitch Disconnectors, Main and EMERGENCY-STOP Switches
General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)
More informationPush buttons and selectors
Accessories and spare parts 8 LM2T A130 8 LM2T A140 8 LM2T A185 8 LM2T AL... Order code Description Qty per Wt 8 LM2T A12❶ Coloured diffuser for 10 0.001 double touch buttons 8 LM2T A130 Threaded plug
More informationSiemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.
KD Switch Disconnectors SENTRON Edition December 01 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10 Electrical Installation Technology SENTRON SIVACON ALPHA
More informationCI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100
MKING MODERN LIVING POSSIBLE Technical brochure CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit- and overload protection of motor applications
More informationAThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.
www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer
More informationApproved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.
Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit
More information60103 Circuit Breaker
6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard
More informationSentron 3VT circuit breakers Simply Smart: First choice for power distribution
s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More informationlow voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters
CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor
More information100% electricity. Automatic transfer switch controllers ATL series
100% electricity Automatic transfer switch controllers ATL series Automatic transfer switch controllers Keep control around the clock General characteristics Rated auxiliary power supply: 220-230-240VAC
More informationMini Contactors & Overloads
108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)
More informationK1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm
Characteristics cam voltmeter switch - 3L and 3L-N - 60-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationSIRCO Load break switches for power distribution from 125 to 5000 A
The solution for Load break switches sirco_456_a_1_cat > Main switchboard > Distribution panel > Emergency breaking > Network coupling > Local safety breaking sirco-ac_001_a_1_cat SIRCO 3 x 250 A direct
More informationK1D012ULH cam changeover switch - 2-pole A - screw mounting
Characteristics cam changeover switch - 2-pole - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing
More informationMULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors
B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationMotor protection circuit breakers
R Motor protection circuit breakers Motor protection circuit breakers are used for start-up and protection of electric motors (industry, small machines, external use, agricultural machines, compressors,
More informationPower factor correction components Planet-SWITCH Planet-DIN Planet-LOGIC
Power factor correction components Planet-SWITCH Planet-DIN Planet-LOGIC 100% ity Automatic power factor regulators DCRK Digital programming 5 or 7 step configuration in 96x96mm housing 8 or 12 step configuration
More informationK1D004ACH cam switch - 4-pole A - for Ø 22 mm
Characteristics cam switch - 4-pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing mode Cam
More informationSiemens AG 2017 SENTRON. 3LD Main Control and EMERGENCY-STOP Switches. Catalog Extract LV 10. Edition 10/2017. siemens.com/switching-devices
Siemens AG 201 SENTRON 3LD Main Control and EMERGENCY-STOP Switches Catalog Extract LV 10 Edition 10/201 siemens.com/switching-devices Siemens AG 201 Related catalogs Low-Voltage Power Distribution and
More informationNF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC1010D0201 28/03/11 NFE-.. / NFZE-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)
More informationDisconnect Switches. Safe Switching and Disconnecting
IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as
More informationMAKING MODERN LIVING POSSIBLE. CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M Technical brochure
MKING MODERN LIVING POSSIBLE CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M - 100 Technical brochure 2 IC.PD.C00.5.02-520B3595 Danfoss /S (R-MC/mr) 08-2009 Contents Page Circuit Breakers/
More informationRM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary
Characteristics voltage control relay RM17-U - range 183..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Time delay
More informationK1B004TLH cam switch - 1 pole A - screw mounting
Characteristics cam switch - 1 pole - 30-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing mode Cam
More informationCI-tronic Reversing contactor Type RCI
Data sheet CI-tronic Reversing contactor Type RCI RCI reversing contactors are designed for demanding forward/reverse control of three-phase AC motors. The zero cross switching method ensures very fast
More informationSOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES
MANALL OPERATED CHANGEOER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application:
More informationMolded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for Type NZMH4-...
Circuit Breakers, 09/054 Moeller Electric Corporation Auxiliary Contacts for Type Contacts Type Suffix Price N.O. = normally open N.C. = normally closed when ordering with basic N.O. N.C. Standard auxiliary
More information194E FA 32 E P11 P11 6
Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable for padlocks) E-FA Painted Steel Enclosure
More information1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control
. Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT
More informationMG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD
United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL
More informationSwitches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors
6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or
More informationLow voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation.
Low voltage NG160 16 to 160 A Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation Catalogue 2010 NG160 circuit breaker Ready to install NG160 General contents Presentation
More informationRM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary
Characteristics voltage control relay RM35-U - range 194..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Time delay
More informationFUSERBLOC UL Fusible disconnect switches UL and CSA 30 to 800 A
Fuse protection The solution for > Motor load break. > Protection of industrial cabinet. > Electrical distribution. ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches
More informationXPSMP11123P module XPS-MP - 2 independent functions - 24 V DC
Characteristics module XPS-MP - 2 independent functions - 24 V DC Main Range of product Product or component type Safety module name Safety module application 1-Nov-2018 Preventa Safety automation Safety
More informationXCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11
Characteristics limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11 Complementary Tracks Switch actuation Electrical connection Contacts insulation form Positive opening Positive opening
More informationRM35TF V AC
Characteristics multifunction phase control relay RM35-T - range 194..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters
More informationK1K015NZ4 cam stepping switch - 2-pole A - screw mounting
Characteristics cam stepping switch - 2-pole - 60-12 A - screw mounting Complementary Number of steps 5 Main Range of product Product or component type Component name [Ith] conventional free air thermal
More informationRM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.
Characteristics voltage control relay RM17-U - range 9..15 V DC Price* : 70.64 GBP Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters
More informationDatasheet - SRB 301LC/B-24V
27.01.2016-00:27:16h Datasheet - SRB 301LC/B-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301LC/B Fit
More informationDatasheet SRB301ST 24V (V.2)
26.10.2016 05:03:31h Datasheet SRB301ST 24V (V.2) Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301ST Suitable
More informationDescription. Installation. Power supply
Air circuit breakers Special versions Series MEGT07 0V/500V/DC 50 up to 5000 A The air circuit breakers MEGT07 are suitable for use as disconnecting switch in DC distributions up to a rated voltage of
More informationSOFT STARTERS PLANET -LOGIC
SOFT STARTERS PAGE -2 ADXM...BP Rated starter current Ie 6 to 45A ratings Rated motor power 2.2 to 22kW at 400VAC Integrated by-pass relay Total protection against over-temperature Acceleration and deceleration
More informationIndicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green
22.5 mm 3.5 mm IP65 1 A 66 VAC Choose one component from each of the coloured sections to assemble a complete switch. For other options or further information please contact your local sales office. INDICATOR
More informationProtection Equipment
Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data
More information1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors
. Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................
More informationMotor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)
More informationM C. Ex d M-0... control, monitoring and signalling devices
Ex d M-0... control, monitoring and signalling devices M-0 M-0 series control, monitoring and signalling devices are installed as external accessories on Cortem 'Ex d' enclosures used in any industrial
More information3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017
3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationFUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A
Fuse protection The solution for > Motor on-load disconnect > Protection of industrial cabinet > Electrical distribution ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches
More informationZB5FG09 flush mounted selector switch head key pos stay put
Characteristics flush mounted selector switch head key 455 3 pos stay put Main Range of product OsiSense XC Series name Standard format Product or component type Limit switch Device short name XCKJ Sensor
More informationOrdering details. Approval. Classification. Global Properties :27:33h. Solenoid interlock / AZM 161I / AZM 161I B6R
13.06.2016 05:27:33h Datasheet AZM 161SK 12/12RI 024 B6R Solenoid interlock / AZM 161I / AZM 161I B6R right hand model Compact design Interlock with protection against incorrect locking. For very smal
More informationXCKS131 limit switch XCKS - thermoplastic roller lever - 1NC+1NO - snap action - Pg13
Characteristics limit switch XCKS - thermoplastic roller lever - 1NC+1NO - snap action - Pg13 Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 80.00 USD Main Range
More informationXCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20
Characteristics limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20 Main Range of product OsiSense XC Series name Standard format Product or component type Limit switch Device
More informationK1F006ALH cam switch - 6-pole A - screw mounting
Characteristics cam switch - 6-pole - 45-12 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting
More informationMotor Control Products Selection Guide
MKING MODERN LIVING POSSIBLE Motor Control Products Selection Guide Contactors, Relays, and Circuit Breakers www.danfoss.com/ia c o n t e n t s Minicontactors CI 5 Thermal Overload Relays TI 9C for Minicontactors
More informationProgram B3 318 Ø 22,5mm. Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320
Push Buttons Index Page Program B3 318 Ø 22,5mm Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320 Rotary Knobs and Swing Knobs 321 Illuminated Rotary Knobs and Swing Knobs 321
More informationOsiSwitch Limit Switches Innovation through modularity
OsiSwitch Limit Switches Innovation through modularity Osiswitch limit switches Simply Smart: Variable composition Note: All outline dimensions are in mm/inches Positive openings with rigid operators and
More informationXCKL115 limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland
Characteristics limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland Complementary Switch actuation Electrical connection Contacts insulation form Number of steps 1 Positive opening
More informationDatasheet - AZ 16-03ZVRK
23.07.2015-02:06:20h Datasheet - AZ 16-03ZVRK Safety switch with separate actuator / AZ 16 Preferred typ Thermoplastic enclosure Double-insulated Large wiring compartment 52 mm x 90 mm x 30 mm Multiple
More informationFor hoisting and mechanical handling, types XCR and XCK-MR For conveyor belt shift monitoring, type XCR-T
For hoisting and mechanical handling, types XCR and XCK-MR For conveyor belt shift monitoring, type XCR-T Presentation XCR With head for rotary movement operators, spring return to off position (1 contact
More information100% electricity. Power factor correction components
100% ity Power factor correction components Automatic power factor regulators DCRK Digital programming 5 or 7 step configuration in 96x96mm housing 8 or 12 step configuration in 144x144mm housing Capacitor
More informationSR2B201FU compact smart relay Zelio Logic - 20 I O V AC - clock - display
Characteristics compact smart relay Zelio Logic - 20 I O - 100..240 V AC - clock - display Main Range of product Product or component type Complementary Local display Number or control scheme lines Cycle
More informationMolded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)6(B)-...
Circuit Breakers, Disconnect Switches, Molded Case Switches 09/064 Moeller Electric Corporation Auxiliary Contacts for. Contacts Type Suffix Price N.O. = normally open N.C. = normally closed when ordering
More informationElectronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet
2CDC 251 116 F0004 1 5 2 4 3 6 Characteristics Single-function ON-delay and OFF-delay timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the time delay Remote potentiometer
More informationMolded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)9-...
Circuit Breakers, 09/074 Moeller Electric Corporation Auxiliary Contacts for Contacts Type Suffix Price N.O. = normally open N.C. = normally closed when ordering with basic device N.O. N.C. Standard auxiliary
More informationsirius Switching. Protecting. Starting. SIRIUS Product Overview
sirius Switching. Protecting. Starting. SIRIUS Product Overview S00 Design Direct-on-line starting Reversing duty Assembly kit for busbar mounting 0 mm: RA9 -C 0 mm: RA9 -D Consisting of: wiring kit busbar
More informationK1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm
Product data sheet Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal
More informationElectrical auxiliaries for ic60, iid, idpn Vigi, isw-na, RCA and ARA
for ic60, iid, idpn Vigi, isw-na, RCA and ARA b The electrical auxiliaries are combined with ic60 circuit breakers, iid residual current circuit breakers, remote tripping switch disconnector isw-na, RCA
More informationRE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O
Characteristics star-delta timing relay - 230VAC/440VAC - 1 C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Complementary Contacts type
More informationModular switch disconnectors and modular change-over switches
Modular switch disconnectors and modular change-over switches Modular switch disconnectors and modular change-over switches The new generation of modular switch disconnectors is guarantee of reliability
More informationmcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches
NEW P. 4 RX3 MCBs 63 A 4500 & 6000 prong type busbar MCBs, RCDs, add-on modules & accessories P. 9 DX3 RCBOs 63 A 6000 / 10 ka AC, A & Hpi type prong & fork type busbar P. 16 DX3 MCBs 63 A 50 ka mcbs,
More informationATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)
Characteristics soft starter-ats22-control 220V-power 230V(4kW)/400...440V(7.5kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG GERMANY This is to certify that representative samples of Motor Controllers, Magnetic (See following pages for additional
More informationXCKM102 limit switch XCKM - steel roller plunger - 1NC +1NO - snap action - Pg11
Characteristics limit switch XCKM - steel roller plunger - 1NC +1NO - snap action - Pg11 Main Range of product OsiSense XC Series name Standard format Product or component type Limit switch Device short
More informationDatasheet - SRB 402EM-24V
Print - Create PDF - Create EXCEL file 20.04.2011-18:31:35h Datasheet - SRB 402EM-24V Output expanders / SRB 402EM Expander module for contact expansion 4 safety contacts, STOP 0 2 Signalling outputs (Minor
More informationTechnical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit
Safety module CS DM-01 Technical data Housing PA 6.6 polyamide housing, self-extinguishing, V0 acc. to UL 94 Protection degree IP40 (housing), IP20 (terminal strip) Dimensions see page 283, design A Two-hand
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationElectronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts
Data sheet Electronic timer CT-SDS. Star-delta change-over with n/o contacts The CT-SDS. is an electronic timer from the CT-S range with Star-delta change-over and 7 time ranges. All electronic timers
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka
DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery
More informationReferences. References. Rating (A) Référence
DIRECT OPERATION T O O R D E R EXTERNAL OPERATION picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_128_a_1_cat acces_129_a_1_cat Direct handle
More information