Aquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors
|
|
- Philomena Rich
- 5 years ago
- Views:
Transcription
1 Aquaflair Air-cooled chillers and free-cooling chillers with double screw compressors BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz The all-in-one solution for your business need Combining cutting-edge technology with energy efficiency and environmental protection. > All the units are all-in-one and completely configurable for easy design and installation, guaranteeing continuous and quiet operations in multiple applications and environmental conditions. > Aquaflair chillers are designed to guarantee total cost of ownership (TCO) reduction and absolute integration in Tier III and IV mission-critical installations.
2 Focus on your core business The optimal solution for IT missioncritical applications > Cutting-edge technology with extensive tests for energy efficiency and continuous avaiability. > Energy savings, complete reliability, and total flexibility guarantee Total cost of ownership (TCO) reduction. > The all-in-one design and the complete configurability allow easy installation and tailored solutions to meet the specific needs of each critical application. Full-load operations in less than three minutes with specific settings permits: > Undersizing of the storage tanks > Continuous chilled water avaiability Units can be fully integrated into the latest generation TIER III and IV data center. The issue-free solution for industrial processes > Needs vary from heat absorption to the necessity to keep components, rooms, and working phases at controlled temperature conditions. > Reliability and easy adjustment of the cooling system to the specific application are key factors to ensure an uninterrupted production and to optimize the process reducing costs. Water inlet temperature up to +30 C (+86 F) and outlet temperature down to -10 C (+14 F) allow application in many industrial processes. ±0.2 C (0.36 F) Close control on water temperature allows use in high-precision applications like laser machineries or biomedical devices. Cooling for innovative building systems > Uniflair long experience on mission-critical installations guarantees investment optimization, short design and on-site operation, complete flexibility, and ease of maintenance. > Aquaflair units are usually installed in hospitals, hotels, and small and large buildings designed for smart operation. Units are natively integrated with Schneider Electric SmartStruxure platform and, with specific adaptor, with all the main BMS platforms. Units are totally assembled, cabled and refrigerant and oil charged in the factory for an easy and quick installation.
3 EER EER Energy efficiency [%] Water temperature [ C] Cooling device integration: The Optimize Management Management of the whole system is the only way to optimize energy consumption and to implement integrated control strategies. All the Schneider Electric cooling resources can therefore be linked* together in a network to maximize the operating parameters and the current required. Row and room cooling units communicate to the chiller, reducing the energy requirement by means of a tracking logic for the current thermal load. The chilled water temperature varies dynamically to minimize compressor consumption and maximize the use of free-cooling, while maintaining the optimum temperature in the data center. * Specific configuration may be required. How it works 0 1, ,0 15 3,0 4,0 5,0 6, EER Operating water temperature Number of units ON Energy saving improvement SUMMER WINTER With optimized management Traditional Min Med Tot Load Min Med Tot Load Comparison between a traditional solution and an optimized management logic Summer mode external temperature: 35 C (95 F) Free-cooling external temperature: 8 C (46.4 F) Load variation: 100 kw 300 kw Water set point: 12 C (53.6 F)
4 All in One Prepackaged solutions Uniflair chillers are designed to integrate the main electrical and hydraulic components onboard the units. In order to reduce the design and installation phases, free-cooling circuit, primary pumps, VSDs, and automatic transfer switches are available to be factory installed Thanks to this logic, the availability level is further increased since the usual single point of failure is removed, for instance: > The integrated ATS connects the unit to both the redundant power supplies. According to the line presence, the unit manages the connection while the control board operates due to the integrated backup system. > An additional external UPS* connection is available for critical components protection. > The default network connection allows for group management without a master or external device which could represent a critical item. > The possibility to choose onboard pumps guarantees better availability when compared to single external pump group. Variable speed driven onboard pumps Choosing the best solution for pumps is certainly one of the most important challenges for the designer. Uniflair chillers have an onboard pump group which can be inverter-driven. Variable speed driven pumps integrated in the units and driven by the chiller controller allow: > Increased efficiency due to the continuous speed adaption on the pressure drops of the circuit. > Increased flexibility and modularity. It is possible to change and adapt the available head pressure from the chiller terminal, guaranteeing on-site optimization and modular installations. > Reduction in capital expense, since a singlecircuit design can be easily applied, saving the extra cost for the additional devices typical of primary/secondary circuits and manifolds, tanks, and secondary pumps. * Specific configurations may be required.
5 Self management Advanced control strategies All the control software solutions for the Aqualflair range are developed by Schneider Electric and specifically designed for each unit configuration, in order to manage all the aspects of the unit. Availability: the monitoring devices onboard the unit allows a preventive maintenance and a check of the working operation while the system is functioning. Amperage monitoring: continuous supervision of the compressors absorbed current to signal possible discrepancies with the default values. Precision: advanced algorithms to accurately control the chilled water temperature. Quick restart: Providing full cooling capacity within three minutes after power failure, optimizing reliability and reducing the capital expense thanks to the downsizing of backup water tanks. Local area network: a shared control between all the available resources for energy optimization and management of emergency situations. Connectivity: the unit sends alarms and data points to manage critical building infrastructure from a single system. Additional network interfaces provide management by connecting the device directly to the network with a dedicated IP address. This eliminates the need for a proxy such as a server. Monitoring is available via Web browser with specific adaptor. Double and/or separate power supply When designing systems for which an uninterrupted service must be provided, reliability is fundamental. The possibility to connect the unit to a secondary power supply guarantees advantages on controls, restarting procedures, and maximize the operational reliability of the units. Installing secondary lines on data centers is a standard practice and Schneider Electric chillers are designed to offer a complete range of solutions to integrate the unit into the system. Main line Generator Main Line Generator Unit Unit
6 Continuous cooling High temperature management The BREC/F units are provided with modulating condensation control: > The influence of the external temperature variations on the condensation pressures are managed by varying the speed of the ventilating sections. > In the event the external temperatures are such that the maximum condensation pressure is reached even with the fans at maximum speed, the control software automatically reduces the capacity of the compressors, consequently reducing the condensation pressure and maintaining the unit in operation, even if with a lower capacity ( Unloading procedure ). Specific solutions for aggressive ambient conditions Units can be fitted with specific solutions in order to guarantee absolute reliability in any climatic condition between -40 C (-40 F) and +50 C (+122 F), including: > Metallic coil filter for sand protection > Cataphoresis treatment in order to protect the surfaces from corrosion > Low ambient temperature option (standard for BREF models) Functional and performance test Schneider Electric guarantees that all the chillers produced in the production facility located in Italy are fully tested at the end of the production process according to the relevant standards. However, it is possible, with previous request, to check the unit performance attending a Factory Admittance Test (FAT)*: these tests are carried-out on the unit in specific climatic conditions, in the R&D laboratories in Conselve (Italy). * Feasibility, costs and dates to be agreed upon in advance with the R&D team of Schneider Electric.
7 Energy consumption/year [kwh] Energy consumption/year [kwh] Free-cooling / Economizer Free-cooling is an efficient method to reduce energy consumption at low outside air temperatures, enhancing the energy optimization. According to the ambient temperature, the chilled water is partially or totally produced exploiting the thermal exchange with the external air. This significantly reduces the chillers energy impact. When the external air temperature is low enough, the microprocessor control system activates the freecooling pump, which circulates water inside special heat exchange coils. Water is cooled by external air brought in by the fans, which, together with the pump, are the only components that absorb energy. Intelligent free-cooling (IFC) Designing a reliable system means choosing units which are both intrinsically reliable and including N+1 or N+N redundancy logic. With IFC, all the available units are connected allowing chilled water to circulate through all the free-cooling coils, thus increasing the free-cooling surface and the benefit in terms of thermal dissipation: +7% +35% * Average values. On Schneider Electric free-cooling* On traditional systems* Glycol-free installations Designed for applications where the use of glycol is not allowed in the data center, this solution uses an intermediate heat exchanger to limit glycol in free-cooling circuit only, while using water in the main circuit. The careful selection and position of the intermediate heat exchanger allows the installation of the onboard main pump too, to minimize the efficiency losses typical of intermediate heat exchangers. delta T = 2 C (3.6 F) in the heat exchanger * Average values. Schneider Electric free-cooling OpEx savings -53% > Load: 1000 KW > Design water temperature: 10 C/15 C (50 F/59 F) -24% Location: Incheon (South Korea) Location: La Paz (Bolivia)
8 Standard features Range Cooling capacity: 350 1,200 kw Available versions - Basic - Compressors soundproof enclosures, vibrations absorbers and low fans speed regulation Refrigerant R134a Double screw compressors Exclusive Uniflair free-cooling system completely managed by the microprocessor control (only BREF model). Self-supporting frame in galvanized steel with panels finished in epoxy powders (color RAL9022). Two semi-hermetic double screw compressors with internal thermal protection, discharge shut-off valve, oil heaters, and anti-vibration supports. Two refrigerant circuits conforming to EC norms (PED 97/23/EC) in copper tubes including: filter dryer, flow indicator, electronic expansion valve managed by the control system, electrovalve on the liquid line, pressure switches, transducers, and manometers of high and low pressure. High efficiency shell and tube single passage evaporator. The heat exchanger is insulated with UV resistant closed cell expanded neoprene. Air side exchange coils with aluminum fins and internally grooved copper tubes. Water flow differential pressure switch. Acousti-Composite fans with electronic commutated motors (EC): sickle-blade axial fans, statically and dynamically balanced, made from composite materials for high efficiency and low acoustic impact with safety protection grilles. Modulating condensation control with fan speed regulation. Electrical panel conforming to EC norms (Directive 2006/95/EC and EMC 2004/108/EC, IP54) with general cut-off switch, power supply electrical distribution bars, acquisition of absorbed current, minimum (optional for BREC units) and maximum internal temperature control, fuses for compressors, fans and auxiliaries. Sequence phase, minimum and maximum power supply monitoring. Free-cooling pump regulated by microprocessor control (only BREF model). Microprocessor control system including: Local user terminal with external accessibility Outlet chilled water temperature regulation by means of an exclusive PID algorithm Electronic expansion valve managed by the control system Advanced control of cooling capacity by automatic set-point sensitivity regulation Refrigerant charge monitoring Monitoring of the absorbed current and checking of possible malfunctions Advanced antifreeze protection on evaporator Integrated LAN card for local network connection of a group of chillers Integrated clock card Integrated RS485 card Rotation of pump group setting functioning and start of pump in standby in the event of pump breakdown USB port Microprocessor control system, in addition, allows: Management of double set point from remote control Limiting of absorbed current on preset value or external signal Rapid quick start procedure to reach total cooling capacity within three minutes Free contact for general alarm and two for addressable alarms Remote ON-OFF switch Compatibility with BMS by means the main protocols: Modbus/RTU, Modbus over IP, LONworks, BacNET MS/TP, BacNET Over IP, Metasys, TCP/IP, SNMP, Trend and Konnex.
9 Construction options Double power supply with automatic integrated management on the active line. Economizer (permits an increase in both capacity and EER). Operation possible with external temperature up to 50 C (122 F) at full load. Ultra-low noise version with soundproof casing and mufflers for the compressors. Intelligent free-cooling for an increase in efficiency with unit in standby. Glycol-free version*. Partial condensation heat recovery. Suction shut-off valves on compressor. Integrated hydronic system with one or two circulation pumps (1+1 standby). Integrated hydronic system with one or two inveterdriven circulation pumps (1+1 standby)*. Condensing and free-cooling coils equipped with metal safety grilles and filters. Coil manifolds protection panels. Condensing and free-cooling coil cataphoresis or prepainting treatment*. The units can be supplied with the following external accessories: Remote user terminal for: - Entering of commands - Display unit status of alarms Spring anti-vibration kit. Flanged type hydraulic connection. Additional RS485 serial adaptor used to communicate with external BMS. LON FTT-10 serial adaptor used to communicate with external BMS managed with LON protocol. TCP/IP serial adaptor used to communicate with external BMS managed with SNMP protocol. * On request. Models BREC 3212 and BREF 3212 are available in High Temperature version only Models BREC 5612 and BREF 5612 are available under request. Please contact Schneider Electric technical department for further information
10 General technical data BREC/F units Model General data Compressors nr./type 2 / Screw Cooling circuits nr. 2 Evaporator nr. 1 Evaporator type type shell & tube Fans nr Dimensions Length mm Width mm Height mm Electrical data 460 V - 3 ph - 60 Hz FLA Standard T 1 A LRA Standard T 1 A FLI Standard T kw FLA High T 1 A LRA High T 1 A FLI High T kw Electrical data Pump and free-cooling pump Main pump FLA (460/3/60) A LRA (460/3/60) A Free cooling pump FLA (460/3/60) A LRA (460/3/60) A Electrical data 380 V - 3 ph - 60 Hz FLA Standard T 1 A LRA Standard T 1 A FLI Standard T kw FLA High T 1 A LRA High T 1 A FLI High T kw Electrical data Pump and free-cooling pump Main pump FLA (380/3/60) A LRA (380/3/60) A Free cooling pump FLA (380/3/60) A LRA (380/3/60) A : Values do not consider pump and free-cooling pump (that are option features). To include FLA and LRA of the pump and/or free cooling pump, add the corresponding values
11 BREC: Performance data Cooling capacity kw Absorbed power 1 kw EER 3,06 3,09 2,84 2,83 2,98 2,86 2,79 2,81 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Cooling capacity Kw Absorbed power 1,2 kw EER 3,23 3,26 2,94 2,92 3,09 2,96 2,88 2,90 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Compressors soundproof enclosures, vibrations absorbers and low fans speed regulation Unit without Economizer SKU Cooling capacity kw Absorbed power 1 kw EER 2,81 2,88 2,66 2,69 2,79 2,69 2,66 2,68 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Unit with Economizer SKU Cooling capacity kw Absorbed power 1,2 kw EER 3,01 3,07 2,82 2,81 2,95 2,85 2,81 2,85 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa : In this nominal condition, fans do not perform in low speed regulation mode Water temperature: 12/7 C (53.6/44.6 F) - External temperature: 35 C (95 F) Glycol 0%, refrigerant R134a - Fouling factor 0.0 m 2 C/W
12 BREC: Performance data Cooling capacity kw Absorbed power 1 kw EER 3,27 3,31 3,04 2,98 3,18 3,04 2,98 2,98 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Cooling capacity kw Absorbed power 1,2 kw EER 3,44 3,48 3,15 3,09 3,30 3,14 3,06 3,06 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa on request Compressors soundproof enclosures, vibrations absorbers and low fans speed regulation 5 Cooling capacity kw Absorbed power 1 kw EER 3,04 3,12 2,88 2,85 3,01 2,90 2,87 2,88 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Cooling capacity kw Absorbed power 1,2 kw EER 3,25 3,33 3,04 3,02 3,20 3,07 3,04 3,05 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa on request : In this nominal condition, fans do not perform in low speed regulation mode Water temperature: 15/10 C (59/50 F) - External temperature: 35 C (95 F) Glycol 0%, refrigerant R134a - Fouling factor 0.0 m 2 C/W
13 BREC: Performance data Cooling capacity kw Absorbed power 1 kw EER 3,61 3,66 3,38 3,27 3,51 3,34 3,29 3,26 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Cooling capacity kw Absorbed power 1,2 kw EER 3,81 3,87 3,51 3,40 3,66 3,46 3,36 3,31 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa on request on request on request on request 106 on request Compressors soundproof enclosures, vibrations absorbers and low fans speed regulation 5 Cooling capacity kw Absorbed power 1 kw EER 3,43 3,51 3,26 3,18 3,41 3,24 3,25 3,23 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Cooling capacity kw Absorbed power 1,2 kw EER 3,68 3,76 3,47 3,39 3,61 3,45 3,36 3,31 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa on request on request on request on request 106 on request 5 : In this nominal condition, fans do not perform in low speed regulation mode Water temperature: 20/15 C (68/59 F) - External temperature: 35 C (95 F) Glycol 0%, refrigerant R134a - Fouling factor 0.0 m 2 C/W
14 BREC: Performance data Cooling capacity kw Absorbed power 1 kw EER 2,63 2,66 2,44 2,47 2,56 2,47 2,40 2,44 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Cooling capacity kw Absorbed power 1,2 kw EER 2,77 2,80 2,54 2,52 2,64 2,55 2,47 2,48 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Compressors soundproof enclosures, vibrations absorbers and low fans speed regulation 5 Cooling capacity kw Absorbed power 1 kw EER 2,54 2,59 2,39 2,43 2,51 2,42 2,40 2,41 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Cooling capacity kw Absorbed power 1,2 kw EER 2,71 2,76 2,53 2,52 2,64 2,55 2,47 2,48 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa : In this nominal condition, fans do not perform in low speed regulation mode Water temperature: 12/7 C (53.6/44.6 F) - External temperature: 40 C (104 F) Glycol 0%, refrigerant R134a - Fouling factor 0.0 m 2 C/W
15 BREC: Performance data Cooling capacity kw Absorbed power 1 kw EER 2,82 2,86 2,62 2,61 2,74 2,63 2,58 2,59 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Cooling capacity kw Absorbed power 1,2 kw EER 2,97 3,01 2,71 2,67 2,82 2,70 2,61 2,61 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Compressors soundproof enclosures, vibrations absorbers and low fans speed regulation 5 Cooling capacity kw Absorbed power 1 kw EER 2,75 2,80 2,59 2,59 2,71 2,61 2,58 2,59 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Cooling capacity kw Absorbed power 1,2 kw EER 2,93 2,98 2,71 2,67 2,82 2,70 2,61 2,61 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa : In this nominal condition, fans do not perform in low speed regulation mode Water temperature: 15/10 C (59/50 F) - External temperature: 40 C (104 F) Glycol 0%, refrigerant R134a - Fouling factor 0.0 m 2 C/W
16 BREC: Performance data Cooling capacity kw Absorbed power 1 kw EER 2,24 2,27 2,08 2,12 2,19 2,10 2,07 2,08 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Unit with Economizer SKU Cooling capacity kw Absorbed power 1,2 kw EER 2,35 2,39 2,15 2,14 2,21 2,14 2,08 2,09 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Compressors soundproof enclosures, vibrations absorbers and low fans speed regulation 5 Cooling capacity kw Absorbed power 1 kw EER 2,23 2,27 2,08 2,12 2,19 2,10 2,07 2,08 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Unit with Economizer SKU Cooling capacity kw Absorbed power 1,2 kw EER 2,35 2,39 2,15 2,14 2,21 2,14 2,08 2,09 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa : In this nominal condition, fans do not perform in low speed regulation mode 6 : In this nominal conditions, the unit must be equipped with High Temperature option Water temperature: 12/7 C (53.6/44.6 F) - External temperature: 45 C (113 F) Glycol 0%, refrigerant R134a - Fouling factor 0.0 m 2 C/W
17 BREC: Performance data Cooling capacity kw Absorbed power 1 kw EER 2,42 2,45 2,24 2,25 2,33 2,24 2,20 2,20 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Unit with Economizer SKU Cooling capacity kw Absorbed power 1,2 kw EER 2,52 2,56 2,29 2,26 2,37 2,27 2,20 2,20 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Compressors soundproof enclosures, vibrations absorbers and low fans speed regulation 5 Cooling capacity kw Absorbed power 1 kw EER 2,42 2,45 2,24 2,25 2,33 2,24 2,20 2,20 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Unit with Economizer SKU Cooling capacity kw Absorbed power 1,2 kw EER 2,52 2,56 2,29 2,26 2,37 2,27 2,20 2,20 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa : In this nominal condition, fans do not perform in low speed regulation mode 6 : In this nominal conditions, the unit must be equipped with High Temperature option Water temperature: 15/10 C (59/50 F) - External temperature: 45 C (113 F) Glycol 0%, refrigerant R134a - Fouling factor 0.0 m 2 C/W
18 BREC: Performance data Unit without Economizer SKU Cooling capacity kw Absorbed power 1 kw EER 2,70 2,74 2,50 2,45 2,59 2,47 2,42 2,41 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Unit with Economizer SKU Cooling capacity kw Absorbed power 1,2 kw EER 2,80 2,85 2,53 2,47 2,63 2,48 2,40 2,37 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa on request Compressors soundproof enclosures, vibrations absorbers and low fans speed regulation 5 Unit without Economizer SKU Cooling capacity kw Absorbed power 1 kw EER 2,70 2,74 2,50 2,45 2,59 2,47 2,42 2,41 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Unit with Economizer SKU Cooling capacity kw Absorbed power 1,2 kw EER 2,80 2,85 2,53 2,47 2,63 2,48 2,40 2,37 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa on request : In this nominal condition, fans do not perform in low speed regulation mode 6 : In this nominal conditions, the unit must be equipped with High Temperature option Water temperature: 20/15 C (68/59 F) - External temperature: 45 C (113 F) Glycol 0%, refrigerant R134a - Fouling factor 0.0 m 2 C/W
19 BREC: Performance data Unit without Economizer SKU Cooling capacity kw Absorbed power 1 kw EER 1,87 1,92 1,76 1,80 1,84 1,77 1,74 1,75 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Unit with Economizer SKU , ,7 Cooling capacity kw Absorbed power 1,2 kw EER 1,95 1,99 1,81 1,80 1,83 1,77 1,74 1,73 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Compressors soundproof enclosures, vibrations absorbers and low fans speed regulation 5 Unit without Economizer SKU Cooling capacity kw Absorbed power 1 kw EER 1,87 1,92 1,76 1,80 1,84 1,77 1,74 1,75 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Unit with Economizer SKU , ,7 Cooling capacity kw Absorbed power 1,2 kw EER 1,95 1,99 1,81 1,80 1,83 1,77 1,74 1,73 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa : In this nominal condition, fans do not perform in low speed regulation mode 6 : In this nominal conditions, the unit must be equipped with High Temperature option 7 : In this nominal conditions, the unit works in Unloading mode Water temperature: 12/7 C (53.6/44.6 F) - External temperature: 50 C (122 F) Glycol 0%, refrigerant R134a - Fouling factor 0.0 m 2 C/W
20 BREC: Performance data Unit without Economizer SKU Cooling capacity kw Absorbed power 1 kw EER 2,03 2,06 1,89 1,91 1,97 1,88 1,86 1,86 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Unit with Economizer SKU , ,7 Cooling capacity kw Absorbed power 1,2 kw EER 2,10 2,14 1,92 1,90 1,96 1,88 1,84 1,83 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Compressors soundproof enclosures, vibrations absorbers and low fans speed regulation 5 Unit without Economizer SKU Cooling capacity kw Absorbed power 1 kw EER 2,03 2,06 1,89 1,91 1,97 1,88 1,86 1,86 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Unit with Economizer SKU , ,7 Cooling capacity kw Absorbed power 1,2 kw EER 2,10 2,14 1,92 1,90 1,96 1,88 1,84 1,83 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa : In this nominal condition, fans do not perform in low speed regulation mode 6 : In this nominal conditions, the unit must be equipped with High Temperature option 7 : In this nominal conditions, the unit works in Unloading mode Water temperature: 15/10 C (59/50 F) - External temperature: 50 C (122 F) Glycol 0%, refrigerant R134a - Fouling factor 0.0 m 2 C/W
21 BREF: Performance data Cooling capacity kw Absorbed power 1 kw 122,7 149,3 177,3 209,6 224,6 264,1 314,4 355,2 EER 3,67 3,73 3,45 3,32 3,61 3,40 3,35 3,31 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Free-cooling capacity kw FC absorbed power 5 kw 19,1 23,2 23,3 24,3 37,9 32,4 41,1 42,3 E.E.R. during free cooling 18,04 17,23 17,38 19,64 13,44 18,56 17,31 17,20 Cooling capacity kw Absorbed power 1,2 kw 134,6 163,6 200,2 236,1 252,2 299,4 361,8 407,1 EER 3,87 3,94 3,57 3,43 3,74 3,50 3,43 3,40 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa on request on request Free-cooling capacity kw FC absorbed power 5 kw 19,5 23,4 23,4 24,3 39,4 32,7 42,2 43,5 E.E.R. during free cooling 17,72 17,07 17,30 19,66 12,95 18,41 16,85 16,71 Compressors soundproof enclosures, vibrations absorbers and low fans speed regulation Unit without Economizer SKU Cooling capacity kw Absorbed power 1 kw 127,6 152,4 186,3 217,6 235,2 275,8 326,9 366,9 EER 3,28 3,45 3,09 3,02 3,24 3,07 3,08 3,06 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Free-cooling capacity kw FC absorbed power 5 kw 12,6 15,0 15,4 17,4 21,4 23,9 32,1 34,3 E.E.R. during free cooling 27,41 26,68 26,38 27,39 23,78 25,14 22,18 21,22 Unit with Economizer SKU Cooling capacity kw Absorbed power 1,2 kw 143,6 172,7 211,1 245,4 265,4 311,6 374,0 418,0 EER 3,45 3,57 3,28 3,21 3,45 3,27 3,26 3,25 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa on request Free-cooling capacity kw FC absorbed power 5 kw 13,9 15,8 17,8 20,0 25,4 22,2 37,0 39,0 E.E.R. during free cooling 24,82 25,33 22,72 23,88 20,11 27,12 19,24 18,62 5 : Data refer to fans and free cooling pump 6 : In this nominal condition, fans do not perform in low speed regulation mode Water temperature: 15/10 C (59/50 F) - External temperature: 30 C (86 F) Glycol 20%, refrigerant R134a - Fouling factor 0.0 m 2 C/W Free cooling data refer to an external temperature of 5 C (41 F)
22 BREF: Performance data Cooling capacity kw Absorbed power 1 kw 130,9 159,4 188,6 226,9 240,5 284,4 335,9 385,8 EER 4,03 4,12 3,82 3,59 3,95 3,69 3,67 3,59 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa on request on request Free-cooling capacity kw FC absorbed power 5 kw 19,5 23,4 23,4 24,2 31,4 32,6 41,9 43,2 E.E.R. during free cooling 17,70 17,06 17,30 19,75 16,23 18,46 16,97 16,84 Cooling capacity kw Absorbed power 1,2 kw 142,3 172,9 210,7 252,1 266,9 317,8 381,7 437,5 EER 4,24 4,35 3,94 3,74 4,11 3,83 3,77 3,69 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa on request on request on request on request 43 on request Free-cooling capacity kw FC absorbed power 5 kw 19,7 23,4 23,5 24,6 32,0 33,6 43,0 43,6 E.E.R. during free cooling 17,52 17,06 17,23 19,42 15,95 17,93 16,53 16,66 Compressors soundproof enclosures, vibrations absorbers and low fans speed regulation Unit without Economizer SKU Cooling capacity kw Absorbed power 1 kw 136,1 164,1 195,3 232,1 248,1 292,2 344,3 392,7 EER 3,64 3,77 3,53 3,39 3,67 3,46 3,48 3,44 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa on request Free-cooling capacity kw FC absorbed power 5 kw 13,7 15,7 17,5 19,7 24,5 27,1 36,0 38,4 E.E.R. during free cooling 25,13 25,48 23,17 24,21 20,79 22,19 19,77 18,91 Unit with Economizer SKU Cooling capacity kw Absorbed power 1,2 kw 148,9 179,5 217,5 257,1 274,9 324,6 386,4 440,1 EER 3,91 4,06 3,75 3,62 3,92 3,69 3,70 3,65 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa on request on request on request on request 49 on request Free-cooling capacity kw FC absorbed power 5 kw 15,5 17,7 19,9 22,1 27,7 30,6 40,8 42,5 E.E.R. during free cooling 22,24 22,55 20,39 21,60 18,38 19,66 17,44 17,12 5 : Data refer to fans and free cooling pump 6 : In this nominal condition, fans do not perform in low speed regulation mode Water temperature: 20/15 C (68/59 F) - External temperature: 30 C (86 F) Glycol 20%, refrigerant R134a - Fouling factor 0.0 m 2 C/W Free cooling data refer to an external temperature of 5 C (41 F)
23 BREF: Performance data Cooling capacity kw Absorbed power 1 kw 132,6 161,2 193,5 225,8 244,5 285,6 342,0 382,2 EER 3,19 3,25 2,98 2,90 3,12 2,95 2,91 2,90 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Free-cooling capacity kw FC absorbed power 5 kw 19,0 23,0 23,2 24,9 31,0 33,0 42,2 43,8 E.E.R. during free cooling 18,19 17,34 17,43 19,19 16,44 18,23 16,87 16,59 Cooling capacity kw Absorbed power 1,2 kw 148,8 180,5 222,6 258,8 280,3 329,1 400,5 446,2 EER 3,34 3,42 3,08 3,00 3,23 3,04 2,98 2,96 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa on request Free-cooling capacity kw FC absorbed power 5 kw 19,5 23,5 24,3 25,7 40,3 29,3 44,2 45,5 E.E.R. during free cooling 17,66 17,01 16,64 18,53 12,66 20,58 16,07 15,98 Compressors soundproof enclosures, vibrations absorbers and low fans speed regulation 6 Cooling capacity kw Absorbed power 1 kw 135,5 163,3 197,2 229,2 248,9 290,5 346,5 386,4 EER 2,97 3,07 2,84 2,78 2,97 2,82 2,81 2,82 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Free-cooling capacity kw FC absorbed power 5 kw 14,1 16,4 18,5 20,8 25,4 28,1 37,4 39,9 E.E.R. during free cooling 24,52 24,30 21,95 22,93 20,04 21,43 19,01 18,22 Cooling capacity kw Absorbed power 1,2 kw 152,8 184,4 226,7 261,3 285,0 332,2 401,7 446,2 EER 3,17 3,27 2,99 2,95 3,14 2,99 2,96 2,96 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa on request Free-cooling capacity kw FC absorbed power 5 kw 16,3 19,0 21,4 24,1 29,6 32,6 43,6 45,5 E.E.R. during free cooling 21,11 20,99 18,89 19,77 17,25 18,48 16,30 15,98 5 : Data refer to fans and free cooling pump 6 : In this nominal condition, fans do not perform in low speed regulation mode Water temperature: 15/10 C (59/50 F) - External temperature: 35 C (95 F) Glycol 20%, refrigerant R134a - Fouling factor 0.0 m 2 C/W Free cooling data refer to an external temperature of 5 C (41 F)
24 BREF: Performance data Cooling capacity kw Absorbed power 1 kw 141,2 171,7 205,0 242,9 260,5 305,9 364,0 413,4 EER 3,52 3,60 3,33 3,19 3,45 3,24 3,22 3,17 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa on request Free-cooling capacity kw FC absorbed power 5 kw 19,5 23,4 24,2 25,6 32,5 34,3 43,9 45,3 E.E.R. during free cooling 17,70 17,06 16,74 18,65 15,70 17,54 16,21 16,05 Cooling capacity kw Absorbed power 1,2 kw 156,1 189,7 232,7 274,9 294,1 347,4 422,0 480,0 EER 3,70 3,80 3,44 3,29 3,58 3,34 3,26 3,20 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa on request on request on request on request 77 on request Free-cooling capacity kw FC absorbed power 5 kw 20,4 24,2 25,0 26,0 33,8 35,3 44,3 44,7 E.E.R. during free cooling 16,95 16,45 16,20 18,33 15,10 17,07 16,04 16,25 Compressors soundproof enclosures, vibrations absorbers and low fans speed regulation 6 Cooling capacity kw Absorbed power 1 kw 143,3 173,3 207,4 244,6 263,2 308,3 365,4 414,0 EER 3,36 3,46 3,23 3,12 3,36 3,17 3,18 3,16 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Free-cooling capacity kw FC absorbed power 5 kw 16,1 18,8 21,0 23,7 28,9 31,8 42,2 44,8 E.E.R. during free cooling 21,38 21,28 19,24 20,15 17,68 18,91 16,85 16,22 Cooling capacity kw Absorbed power 1,2 kw 158,4 192,0 234,0 274,9 295,2 347,4 422,0 480,0 EER 3,59 3,70 3,40 3,29 3,56 3,34 3,26 3,20 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa on request on request on request on request 77 on request Free-cooling capacity kw FC absorbed power 5 kw 18,3 21,3 24,1 26,0 33,0 35,3 44,3 44,7 E.E.R. during free cooling 18,87 18,71 16,83 18,33 15,45 17,07 16,04 16,25 5 : Data refer to fans and free cooling pump 6 : In this nominal condition, fans do not perform in low speed regulation mode Water temperature: 20/15 C (68/59 F) - External temperature: 35 C (95 F) Glycol 20%, refrigerant R134a - Fouling factor 0.0 m 2 C/W Free cooling data refer to an external temperature of 5 C (41 F)
25 BREF: Performance data Cooling capacity kw Absorbed power 1 kw 143,8 174,6 211,0 243,4 266,6 308,5 372,1 412,6 EER 2,75 2,81 2,58 2,53 2,69 2,57 2,51 2,52 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Free-cooling capacity kw FC absorbed power 5 kw 19,6 23,7 24,7 26,4 39,1 31,0 43,8 45,3 E.E.R. during free cooling 17,63 16,80 16,37 18,08 13,05 19,44 16,24 16,06 Cooling capacity kw Absorbed power 1,2 kw 164,0 199,1 247,3 285,0 312,6 363,3 446,5 494,1 EER 2,88 2,95 2,66 2,59 2,77 2,61 2,54 2,52 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa on request Free-cooling capacity kw FC absorbed power 5 kw 20,7 25,0 25,5 26,5 33,9 40,3 44,4 45,6 E.E.R. during free cooling 16,67 15,98 15,90 18,02 15,06 14,93 16,00 15,95 Compressors soundproof enclosures, vibrations absorbers and low fans speed regulation 6 Cooling capacity kw Absorbed power 1 kw 144,5 174,8 211,6 243,8 267,4 309,1 372,1 412,6 EER 2,68 2,75 2,55 2,52 2,66 2,55 2,51 2,52 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Free-cooling capacity kw FC absorbed power 5 kw 17,0 20,1 22,8 25,4 30,9 34,1 43,8 45,3 E.E.R. during free cooling 20,32 19,89 17,76 18,76 16,53 17,67 16,24 16,06 Cooling capacity kw Absorbed power 1,2 kw 164,6 199,6 247,3 285,0 312,6 363,3 446,5 494,1 EER 2,86 2,93 2,66 2,59 2,77 2,61 2,54 2,52 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa on request Free-cooling capacity kw FC absorbed power 5 kw 19,8 23,7 25,5 26,5 33,9 40,3 44,4 45,6 E.E.R. during free cooling 17,39 16,86 15,90 18,02 15,06 14,93 16,00 15,95 5 : Data refer to fans and free cooling pump 6 : In this nominal condition, fans do not perform in low speed regulation mode Water temperature: 15/10 C (59/50 F) - External temperature: 40 C (104 F) Glycol 20%, refrigerant R134a - Fouling factor 0.0 m 2 C/W Free cooling data refer to an external temperature of 5 C (41 F)
26 BREF: Performance data Cooling capacity kw Absorbed power 1 kw 152,6 185,5 222,9 261,6 282,9 330,0 396,2 446,6 EER 3,06 3,14 2,88 2,78 2,99 2,82 2,77 2,74 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Free-cooling capacity kw FC absorbed power 5 kw 20,5 24,7 25,5 26,5 33,8 35,2 44,4 45,6 E.E.R. during free cooling 16,86 16,15 15,91 18,01 15,08 17,09 16,02 15,95 7 Cooling capacity kw Absorbed power 1,2 kw 171,4 208,2 258,5 303,1 326,6 383,4 469,7 530,7 EER 3,21 3,29 2,94 2,82 3,06 2,85 2,77 2,72 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa on request on request on request on request Free-cooling capacity kw FC absorbed power 5 kw 21,2 25,5 25,5 26,2 34,1 35,3 44,5 45,2 E.E.R. during free cooling 16,26 15,65 15,90 18,19 14,95 17,03 15,99 16,10 Compressors soundproof enclosures, vibrations absorbers and low fans speed regulation 6 Cooling capacity kw Absorbed power 1 kw 152,8 185,6 222,9 261,6 282,9 330,0 396,2 446,6 EER 3,03 3,11 2,88 2,78 2,99 2,82 2,77 2,74 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Free-cooling capacity kw FC absorbed power 5 kw 19,3 22,9 25,5 26,5 33,8 35,2 44,4 45,6 E.E.R. during free cooling 17,87 17,40 15,91 18,02 15,08 17,08 16,02 15,95 7 Cooling capacity kw Absorbed power 1,2 kw 171,4 208,2 258,5 303,1 326,6 383,4 469,7 530,7 EER 3,21 3,29 2,94 2,82 3,06 2,85 2,77 2,72 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa on request on request on request on request Free-cooling capacity kw FC absorbed power 5 kw 21,2 25,5 25,5 26,2 34,1 35,3 44,5 45,2 E.E.R. during free cooling 16,26 15,65 15,90 18,19 14,95 17,03 15,99 16,10 5 : Data refer to fans and free cooling pump 6 : In this nominal condition, fans do not perform in low speed regulation mode 7 : In this nominal conditions, the unit must be equipped with High Temperature option Water temperature: 20/15 C (68/59 F) - External temperature: 40 C (104 F) Glycol 20%, refrigerant R134a - Fouling factor 0.0 m 2 C/W Free cooling data refer to an external temperature of 5 C (41 F)
27 BREF: Performance data Cooling capacity kw Absorbed power 1 kw 156,1 189,6 230,4 264,8 292,2 335,2 406,5 447,9 EER 2,35 2,41 2,20 2,17 2,28 2,18 2,13 2,14 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Free-cooling capacity kw FC absorbed power 5 kw 20,2 24,8 25,0 26,3 33,1 31,0 43,4 44,9 E.E.R. during free cooling 17,06 16,10 16,18 18,15 15,43 19,39 16,40 16,18 Unit with Economizer SKU Cooling capacity kw Absorbed power 1,2 kw 181,6 220,3 276,1 315,6 351,5 403,2 498,4 548,2 EER 2,44 2,51 2,25 2,19 2,32 2,19 2,14 2,12 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Free-cooling capacity kw FC absorbed power 5 kw 20,8 25,2 25,4 26,5 33,7 30,7 44,3 45,5 E.E.R. during free cooling 16,62 15,82 15,93 18,01 15,12 19,61 16,06 15,96 Compressors soundproof enclosures, vibrations absorbers and low fans speed regulation 6 Cooling capacity kw Absorbed power 1 kw 156,1 189,6 230,4 264,8 292,2 335,2 406,5 447,9 EER 2,35 2,41 2,20 2,17 2,28 2,18 2,13 2,14 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Free-cooling capacity kw FC absorbed power 5 kw 20,2 24,8 25,0 26,3 33,1 31,0 43,4 44,9 E.E.R. during free cooling 17,06 16,10 16,18 18,15 15,43 19,39 16,40 16,18 Unit with Economizer SKU Cooling capacity kw Absorbed power 1,2 kw 181,6 220,3 276,1 315,6 351,5 403,2 498,4 548,2 EER 2,44 2,51 2,25 2,19 2,32 2,19 2,14 2,12 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa on request Free-cooling capacity kw FC absorbed power 5 kw 20,8 25,2 25,4 26,5 33,7 30,7 44,3 45,5 E.E.R. during free cooling 16,62 15,82 15,93 18,01 15,12 19,61 16,06 15,96 5 : Data refer to fans and free cooling pump 6 : In this nominal condition, fans do not perform in low speed regulation mode 7 : In this nominal conditions, the unit must be equipped with High Temperature option Water temperature: 15/10 C (59/50 F) - External temperature: 45 C (113 F) Glycol 20%, refrigerant R134a - Fouling factor 0.0 m 2 C/W Free cooling data refer to an external temperature of 5 C (41 F)
28 BREF: Performance data Unit without Economizer SKU Cooling capacity kw Absorbed power 1 kw 165,1 200,8 243,4 283,5 308,7 357,5 432,5 484,7 EER 2,63 2,69 2,46 2,39 2,55 2,40 2,35 2,34 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Free-cooling capacity kw FC absorbed power 5 kw 20,7 25,2 25,4 26,5 33,6 35,1 44,1 45,5 E.E.R. during free cooling 16,67 15,85 15,96 18,02 15,18 17,17 16,11 15,98 Unit with Economizer SKU ,8 Cooling capacity kw Absorbed power 1,2 kw 189,2 229,6 287,7 335,2 364,0 423,2 522,8 587,8 EER 2,71 2,80 2,48 2,39 2,57 2,39 2,32 2,28 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa on request Free-cooling capacity kw FC absorbed power 5 kw 21,1 25,5 25,5 26,4 34,0 35,3 44,5 45,5 E.E.R. during free cooling 16,36 15,67 15,88 18,08 14,99 17,03 15,97 16,00 Compressors soundproof enclosures, vibrations absorbers and low fans speed regulation 6 Unit without Economizer SKU Cooling capacity kw Absorbed power 1 kw 165,1 200,8 243,4 283,5 308,7 357,5 432,5 484,7 EER 2,63 2,69 2,46 2,39 2,55 2,40 2,35 2,34 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa Free-cooling capacity kw FC absorbed power 5 kw 20,7 25,2 25,4 26,5 33,6 30,8 44,1 45,5 E.E.R. during free cooling 16,67 15,85 15,96 18,02 15,18 19,55 16,11 15,98 Unit with Economizer SKU ,8 Cooling capacity kw Absorbed power 1,2 kw 189,2 229,6 287,7 335,2 364,0 423,2 522,8 587,8 EER 2,71 2,80 2,48 2,39 2,57 2,39 2,32 2,28 Water flow l/h Evaporator pressure drop 3 kpa Available head pressure 4 kpa on request Free-cooling capacity kw FC absorbed power 5 kw 21,1 25,5 25,5 26,4 34,0 30,0 44,5 45,5 E.E.R. during free cooling 16,36 15,67 15,88 18,08 14,99 20,09 15,97 16,00 5 : Data refer to fans and free cooling pump 6 : In this nominal condition, fans do not perform in low speed regulation mode 7 : In this nominal conditions, the unit must be equipped with High Temperature option 8 : In this nominal conditions, the unit works in Unloading mode Water temperature: 20/15 C (68/59 F) - External temperature: 45 C (113 F) Glycol 20%, refrigerant R134a - Fouling factor 0.0 m 2 C/W Free cooling data refer to an external temperature of 5 C (41 F)
29 BREC - Operating limits > Units can operate with chilled water outlet temperature > 20 C, while these operations must be checked with Schneider Electric > Units equipped with subcooling economizer can operate continuously in areas out of the limits by switchingoff the economizer. This operation is automatically carried out by the control board and it allows to operate at the limits as per units without economizer > Operating conditions in areas out of the limits above are managed automatically by the control board. This unloading procedure allows operation, although with a lower cooling capacity (no high pressure trip)
30 BREF - Operating limits > Units can operate with chilled water outlet temperature > 20 C, while these operations must be checked with Schneider Electric > Units equipped with subcooling economizer can operate continuously in areas out of the limits by switchingoff the economizer. This operation is automatically carried out by the control board and it allows to operate at the limits as per units without economizer > Operating conditions in areas out of the limits above are managed automatically by the control board. This unloading procedure allows operation, although with a lower cooling capacity (no high pressure trip) > Operations with ambient temperature lower than -5 C are possible on request
31 SmartStruxture solution SmartStruxure solution enables you to monitor, measure, and optimize your building s performance throughout its life cycle saving energy while saving money. Because you can t control what you don t measure, SmartStruxure solution facilitates the exchange and analysis of data from energy, lighting, fire safety, and HVAC. The intelligent energy management approach Your complex energy challenges require a stronger and more effi cient collaboration between your organization s key stakeholders. They demand comprehensive solutions that include enterprise-wide management of power, IT, HVAC, and security, with a level of intelligence that involves system dynamics across segments, platforms, and providers. Schneider Electric SmartStruxure platform integrates multiple systems on one network to reduce training, operations, maintenance, and energy costs, which improves comfort and increases productivity. Combining industry-standard technology with an easyto- use interface, SmartStruxure produces an integrated building management solution that is reliable, flexible, and cost-effective. Full integration of environmental control as well as facility and energy management in a single software package allows you to customize SmartStruxure for any building and security management application. Integrated and intelligent systems deliver choices SmartStruxure gives customers the freedom to select products from a wide range of suppliers, yielding true vendor independence. SmartStruxure runs on Microsoft Windows with standard LAN communication on Ethernet or fi ber optics using TCP/IP and standard network equipment. Field bus communication features open LonWorks, Modbus, and/or BACnet technology, which are used by more than 3,000 vendors worldwide. TCP/IP offers a variety of networking architecture options Using TCP/IP, SmartStruxure host workstations can communicate across the Internet and existing commercial WAN/LANs. The SmartStruxure flexible architecture makes it highly scalable SmartStruxure is well suited for any building management application, regardless of the size, the business, number of buildings, or what distances separate the buildings. SmartStruxure manages multicampus applications just as efficiently as single, small sites. Aquaflair range is natively integrated with Schneider Electric SmartStruxure Unifl air chillers allow a complete and easy integration into SmartStruxure. Units are able to send alarms and data points to the system in order to manage and optimize any critical infrastructure from a local or remote location.
32 June Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies.
Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.
Aquaflair Uniflair TRAC, TRAF and TRAH Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors 120-350kW Uniflair TRA ranges 115-350kW Air-cooled Chillers Cooling, Free cooling
More informationAquaflair. BREC/F and BCEC/F kw
Aquaflair Air-cooled chillers and free-cooling chillers with screw or oil-free centrifugal compressors equipped with adiabatic system BREC/F and BCEC/F 350-1350 kw Dualism for evolution: the combination
More informationAIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS
RAH 913 K AIR R-407C R-134a Series RAH... from 307 to 1879 kw - from 1 to 4 circuits The air cooled chillers of RAH series are extremely compact units so to reduce the installation spaces and weights.
More informationAIR COOLED HEAT PUMPS WITH SCREW COMPRESSORS AND AXIAL FANS
PAH 2802 T K AIR R-407C R-134a Series PAH... T K from 205 to 778 kw - 2 circuits The air cooled heat pumps of PAH.T series are designed for outdoor installation and are particularly suitable for industrial
More informationCHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw
IT COOLING CLOSE CONTROL AIR CONDITIONERS CHILLED WATER HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw 3 Versions available Single chilled water coil Double chilled water coil High temperature IT COOLING
More informationPrecision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers
Precision Cooling for Business-Critical Continuity Liebert HPC-S Designed for the Efficient Cooling of Small Data Centers Liebert HPC-S: Enhanced Efficiency Freecooling Chiller Higher energy costs, limited
More informationMotivair MLC-SC Air-Cooled Scroll Chillers Tons
INNOVATE DESIGN APPLY www.motivaircorp.com Motivair MLC-SC Air-Cooled Scroll Chillers 100 285 Tons OUR BUSINESS IS COOLING YOURS. When commercial grade isn t enough Businesses who function in today s advanced
More informationRack cooling solutions for high density racks management, from 10 to 75 kw
Rack cooling solutions for high density racks management, from 10 to 75 Superior efficiency, high reliability, low energy consumption Modern data center are characterized by 24/7 operation all year long.
More informationNew Design Strategies for Energy Saving. Intelligent free-cooling
New Design Strategies for Energy Saving Intelligent free-cooling Intelligent New strategies for energy saving When designing mission critical systems for processing applications or highly technological
More informationglide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA
99 glide air cooled liquid chillers ND free cooling chillers glider 178 1328 Energy Class More efficient + B C D E F G Less efficient R134a CLSS SHELL C E C FREE COOLING 100 air cooled liquid chiller and
More informationProduct Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres
Product Brochure DENCO Close Control Units Row-DENCO High Density Cooling for Data Centres Data Centre Cooling Through a history in close control, we have developed a broad and deep understanding of how
More informationCTC Low Temperature Process Chillers
INNOVATE DESIGN APPLY CTC Low Temperature Process Chillers 5-500 Tons OUR BUSINESS IS COOLING YOURS TM When commercial grade isn t enough When it comes to process cooling, every application is unique in
More informationCHAPTER 1. Unit CHA/IK/WP CHA/CLK CHA/ML/ST CHA/ML/ST CHA/ML/ST 182-P 302-P 50-51
CHAPTER AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Unit Page CHA/IK/WP - CHA/CLK 8 - CHA/ML/ST - CHA/ML/ST 9 8-9 CHA/ML/ST 8-P 0-P 0 - FROM, KW TO KW. CHA/IK/WP
More informationEcoflair Air Economizers
Ecoflair Air Economizers Cooling to maximize value for the cloud schneider-electric.com/ecoflair Life is On Schneider Electric 1 Ecoflair takes data center efficiency to new heights 2 Imagine cooling your
More informationMLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers
INNOVATE DESIGN APPLY www.motivaircorp.com MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers 60-500 Tons OUR BUSINESS IS COOLING YOURS TM When commercial grade isn t enough
More informationCHAPTER 3 WATERCOOLED & CONDENSERLESS LIQUID CHILLERS AND HEAT PUMPS FOR COMMERCIAL & INDUSTRIAL APPLICATION. REMOTE CONDENSERS
CHAPTER WATERCOOLED & CONDENSERLESS LIQUID CHILLERS AND HEAT PUMPS FOR COMMERCIAL & INDUSTRIAL APPLICATION. REMOTE CONDENSERS Unit Page CWW/K 8-9 CWW/K 8-P 0-P 0 - CWW/K 8 0 - MEA/K - MEA/K 8-P 0-P - RCA/K
More informationIT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw
IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE
More informationIT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw
IT COOLING EVAPORATIVE COOLING SYSTEM 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 8 TO 3 kw IT COOLING EVAPORATIVE COOLING SYSTEM ADIABATIC COOLING FOR HIGH EFFICIENCY - Variable
More informationPT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone
PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 0 Jl. Malibu Raya, Cengkareng Jakarta Barat 70 Indonesia Phone + 4 4 www.climanusa.com Marketing features prominent presence on the world
More informationAPPLIED SYSTEM AWS FAMILY FOR LARGE APPLICATIONS PRODUCT LEAFLET. Capacity from 600 to 2,010kWr. Engineered for flexibility and performance
APPLIED SYSTEM AWS FAMILY FOR LARGE APPLICATIONS Capacity from 600 to 2,010kWr Engineered for flexibility and performance PRODUCT LEAFLET THE AWS SERIES OFFERS TOP EFFICIENCY, LOW SOUND LEVELS AND FLEXIBLE
More informationAiredale International Air Conditioning Limited. Leeds Road, Rawdon Leeds, LS19 6JY, England
> For the latest information on our products please visit : www.airedale.com > Please refer to the technical manuals for more detailed information Your nearest Airedale distributor is: ISO 14001 EMS52086
More informationLiebert HPC Freecooling Chiller
Precision Cooling for Business-Critical Continuity Liebert HPC Freecooling Chiller Data Center Freecooling with 100% Compressor Back Up Whether a Data Center houses three or 1000 IT racks, deployment of
More informationReliability and extended operation
CLIMAVENETA TELECOMSOLUTIONS Units for mobile telecounication applications, with free cooling and full DC Inverter technology. 1,5 20. Low operational and maintenance costs Wide range of full inverter
More informationHIGH EFFICIENCY Central Chiller
Blending Conveying Drying Process Cooling Heat Transfer Size Reduction HIGH EFFICIENCY Central Chiller Energy Efficient Modular & Expandable Virtually Eliminate Downtime Available in 20-60 ton single units,
More informationGP SERIES Packaged Chillers
Blending Conveying Drying Process Cooling Heat Transfer Size Reduction GP SERIES Packaged Chillers Comprehensive Flexible Versatile Compact unitary designs available in a variety of configurations from
More informationCLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit
CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW The indirect evaporative free-cooling Air Handling Unit Flexible & Efficient 11 sizes from 30 kw up to 520 kw to fit your needs with maximum efficiency
More information4-step Chiller and Heat Pump Controller
4-step Chiller and Heat Pump Controller Technical Data Sheet GENERAL DESCRIPTION MODELS CODE MODEL DESCRIPTION MW324000 ECH 420 HEAT PUMP WITH 4 STEPS/ 2 CIRCUITS + MODBUS MW324005 ECH 420/V WITH SCREW
More informationMPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers
INNOVATE DESIGN APPLY www.motivaircorp.com MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers ½ - 100 Tons OUR BUSINESS IS COOLING YOURS. When commercial grade isn t enough Motivair is a world-class
More information2018 Product overview
2018 Product overview Project conditioning Evolution goes on During these years, the activity of EMICON has been developed with the production of liquid chillers for conditioning and industrial applications,
More informationChilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers
Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers DATA CENTER COOLING EXPERTISE Data Center managers have unique needs. Nortek Air Solutions listens
More informationChiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw
Chiller CG 010 to 130 Remote Air Cooled Condensers Engineering Data Manual 9.4 to 131 kw Specifications Unit identification CG. O. O55. FSC. R407C LN Configuration Refrigerant rpm fans Size Air flow Remote
More informationkyalfa V- VDD/VDD6 General Contents
General Contents. kyalfa V- VDD/VDD6 ky General Contents General Features A dry cooler is a forced convection air-cooled fluid cooler, designed for outdoor installation. Air is forced over the finned coil
More informationCooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS
Cooling > Highly efficient cooling products for any IT application. DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com End-to-End Cooling Solutions from the Closet to the Data
More informationSemi-hermetic Air-cooled Condensing Units
Semi-hermetic Air-cooled Condensing Units For Indoor and Outdoor Applications DFA-002-1 R22 R404A R507 R22 DFA Indoor Model Standard Features Bitzer OCTAGON series compressors up to 7 ½ HP. Dual adjustable
More informationDigital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect
Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect of Record: SPARCH Project Overview The project is located
More informationPrecision Cooling Mission Critical Air Handling Units
M I S S I O N C R I T I CA L C O O L I N G Precision Cooling Mission Critical Air Handling Units Global Expertise for Precision Cooling Solutions STULZ is a privately owned, global manufacturer of highly
More informationHIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity
ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) Product Specifications HIGH EFFICIENCY 15 and 17 TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208 / 230 Volt,
More informationClose-coupled cooling
Close-coupled cooling Intelligently controlled high-performance InRow cooling for the IT environment APC TM by Schneider Electric close-coupled cooling products provide a modular, scalable, and predictable
More informationControl system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication
X X testregistrierung Control system Type Central BMS interface DCP-FSL II-Stand-alone Pressure independent control valve Straight-way valve Modular, stand-alone room control system, specially for decentralised
More information30XAV & 30XWV. Air and water-sourced, variable-speed screw units. AquaForce with Greenspeed intelligence, Because you should not have to choose.
d e s i g n i n g i n n o v a t i v e s o l u t i o n s Air conditioning & HEATING SOLUTIONS F O R C E or Intelligence? AquaForce with Greenspeed intelligence, Because you should not have to choose. Air
More informationYour Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant
Your Solution For Energy and Cost Savings McQuay Packaged Chiller Plant Innovative Solutions for Your Chiller Plant McQuay packaged chiller plants provide energy efficient chillers integrated with pumps,
More informationBlue e+ chillers with the principle
Blue e+ chillers with the principle Blue e+ chillers The world s most efficient range of chillers. The principle: Efficient Energy savings of up to 70% thanks to DC inverter technology Flexible Worldwide
More informationPrecision Cooling for Business-Critical Continuity. Liebert HPC-M. The Data Center FreeCooling Chiller with the Lowest Impact on the Environment
Precision Cooling for Business-Critical Continuity Liebert HPC-M The Data Center FreeCooling Chiller with the Lowest Impact on the Environment Emerson Network Power, a division of Emerson Electric Co.,
More informationA Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System
A Data Center Heat Removal System That Saves... Infrastructure Power Water up to 40% up to 80% up to 85% Discover Inertech s Award-winning Data Center Heat Removal System A Cool Solution; A Breakthrough
More information09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD
Air-Cooled Condensers/Air-Cooled Fluid Coolers 09LD/GD 09GD 09LD/GD Nominal cooling capacity 281-987 kw The 09LD air-cooled condensers are designed for refrigeration plants where a halogenated hydrocarbon,
More informationLiebert HPC. Freecooling Scroll Chillers for the Efficient Cooling of Data Centers
Liebert HPC Freecooling Scroll Chillers for the Efficient Cooling of Data Centers Liebert HPC: Freecooling Solutions for Increased Data Center Efficiency and PUE of 1.1 Freecooling data center chillers
More informationTrailblazer AGZ-E air-cooled scroll chillers
Trailblazer AGZ-E air-cooled scroll chillers 30 to 240 tons with Variable Speed Condenser Fan Technology The right features, the right value, right now Intelligent Equipment AGZ-E 30 to 161 RapidRestore
More informationLarge Tonnage Chillers. Kingsley Hu Technical Support Engineer
Large Tonnage Chillers Kingsley Hu Technical Support Engineer Chongqing Plant Chiller Products Reference Projects Manufacturing Facility Major Milestones Global R&D Talent Production Line introduction
More informationWO P-NF-L-M-407c Spec Submittal
WO2-2-10000-2P-NF-L-M-407c Spec Submittal General Specifications WO2-2-10000(801304) Width: IN/CM 136.25/346.07 Height: IN/CM 84.5/214.63 Depth: IN/CM 41.7/105.92 Dry weight: LB/KG 4000/1814.37 Operational
More informationUser Guide. Multipipe Units CMAA / RTMA CNT-SVU004B-GB
User Guide Multipipe Units CMAA / RTMA CNT-SVU004B-GB USER GUIDE WARNING Supply the unit at least 24 hours before the initial startup to heat the compressor oil. In conditions of low water temperature,
More informationFuture of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power
Future of Cooling High Density Equipment Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power Agenda Issues facing the Data Center Managing the explosive
More informationAir-Cooled Series R Chiller
Air-Cooled Series R Chiller The next generation of Air-Cooled Helical Rotary Chillers ANOTHER RELIABLE SOURCE OF CHILLED WATER FROM TRANE The new industry standard f The next generation of the air-cooled
More informationNEOSTAR AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE HFC. 18 > 1240 kw. NEOSTAR POWER The choice of performance and low space requirement.
AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE Hard Discount - Supermarkets - Hypermarkets Refrigerated storage and transit stocking - Dispatch centres Food processing - Canteen kitchens HFC 18 >
More informationFilter Fan Unit LIGHT
Filter Fan Unit LIGHT Type LIGHT EC Technical Concept Technical Concept Filter Fan Unit LIGHT Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air to individual
More informationMCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH
MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal
More informationHigh-Efficiency Room Air Conditioners
High-Efficiency Room Air Conditioners High Efficiency Room Air Conditioners 1 Uniflair and EcoBreeze Air conditioners designed for precision environmental control of mission-critical applications ^ High
More informationTotal Modular Data Centre Solutions
Sector Data Centre Total Modular Data Centre Solutions www.airedale.com BRITISH MANUFACTURER ENERGY EFFICIENCY CONTROLS SERVICE TRAINING 01 Standardised Modular Designs to fit your needs Our modular system
More informationICS COOL ENERGY THE TEMPERATURE CONTROL SPECIALISTS
ICS COOL ENERGY THE TEMPERATURE CONTROL SPECIALISTS GLOBAL PRESENCE, LOCAL SERVICE WHERE WE MAKE IT WORK WHO WE MAKE IT WORK FOR ACCREDITATIONS i-chiller -10 C to 30 C 1.7 TO 505kW i-chiller COMPACT
More informationMCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH
MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH 1 Chilled and Hot Water Fan Coil Low Static 4-Pipe Nominal Size:
More informationSmoothAir Modular Precision Cooling
TM SmoothAir Modular Precision Cooling ODM/OEM/Customization+ Specialist Support+ Modular Precision Cooling for Smart, Reliable and Green MDC Solution Why Choose Us Products Support Customization Products
More informationLiebert PDX from 15 to 120 kw
Liebert PDX from 5 to 0 kw The Thermal Management Solution for Small and Medium Data Centers Electronic Expansion Valve Efficiency Digital Scroll Partial Load icom Control TCO Optimization Integrated Solution
More informationLiquid Cooling Package LCP Cooling Systems
Liquid Cooling Package LCP Cooling Systems 2 Rittal LCP The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure,
More informationMission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire
Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101 Nick Gangemi Regional Sales Manager Data Aire Agenda Exactly what are we talking about ASHRAE TC 9.9 Design best practices
More informationPassive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer
Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling Jeremiah Stikeleather Applications Engineer Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling While CRAH cooling has been
More informationCHILLERS & HEAT PUMPS DYNACIAT HIGH ENERGY PERFORMANCE WITHIN OPTIMISED FOOTPRINT
CHILLERS & HEAT PUMPS DYNACIAT HIGH ENERGY PERFORMANCE WITHIN OPTIMISED FOOTPRINT DYNACIAT: HIGH PERFORMANCE HEATING AND COOLING FOR MEDIUM-SIZED BUILDINGS To better meet customer needs and answer environmental
More informationLiebert PDX from 15 to 120 kw
Liebert PDX from 5 to 0 kw The Thermal Management Solution for Small and Medium Data Centers Electronic Expansion Valve Efficiency Digital Scroll Partial Load icom TM Control TCO Optimization Integrated
More informationMCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH
MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal
More informationU-Match Series DC Inverter Service Manual PRODUCT
PRODUCT 1 PRODUCT 1 MODELS LIST 1.1 Outdoor Unit Name Product Code Power Supply (V, Ph, Hz) Appearance GUHD24NS3GO CF090W0800 220-240V~ 50/60Hz GUHD36NS3GO CF090W0860 220-240V~ 50/60Hz GUHD42NS3GO CF090W0870
More informationSTANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request
PRODUCT DATA & SPECIFICATIONS Bulletin B40-BC-PDS Part # 1106712 PRODUCT SUPPORT web: b-rp.ca/bc email: multicompcu@b-rp.ca call: 1-844-893-3222 x524 scan: BC Combination Condensing Units Cooler/Freezer
More informationUPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications
INFINITE POWER Mission Critical Applications UPS UNINTERRUPTIBLE POWER SUPPLY centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw Rack-mountable modules designed for blades, data-center,
More informationLiebert HPC. Data Center Freecooling Chiller with 100% Compressor Back Up
Liebert HPC Data Center Freecooling Chiller with 100% Compressor Back Up Liebert HPC Freecooling Chiller Vertiv Vertiv designs, builds and services mission critical technologies that enable the vital applications
More informationRittal Cooling Solutions A. Tropp
1 Rittal Cooling Solutions Presented by Adam Tropp 2 Agenda Cooling Strategies Aisle Containment Chimney Solution Airstream Management Rittal Liquid Cooling Packages Data Monitoring 3 Cooling strategies.
More informationLiebert. PCW from 25 to 220 kw. Chilled Water Units Optimizing Data Center Efficiency
Liebert PCW from 25 to 220 kw Chilled Water Units Optimizing Data Center Efficiency LIEBERT PCW from 25 to 220 kw Vertiv Vertiv designs, builds and services mission critical technologies that enable the
More informationThe new generation of dedicated HVAC drives
The new generation of dedicated HVAC drives Contents Selection guides p. 8 Presentation p. 14 References p. 18 Bus and communication networks p. 26 Motor starters p. 28 Altivar 212 Orientated towards performance,
More informationCeiling Concealed Split System C Series
Brochure AP MCC C 07A Ceiling Concealed Split System C Series features: Microprocessor Controlled ith the microprocessor controlling the operation, the MCC model can offer comfortable room conditions according
More informationTechnical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC
Technical Concept Filter Fan Unit LIGHT Type LIGHT AC Type LIGHT EC Filter Fan Unit LIGHT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air
More informationWe design and produce special units for applications in air conditioning, refrigeration and air treatment systems, specifically developed to meet our
We design and produce special units for applications in air conditioning, refrigeration and air treatment systems, specifically developed to meet our clients requirements and with the lowest environmental
More informationTECHNICAL MANUAL WATER 300 C 5300 CV/06-00 GB
T E C H N I C A L M A N U A L TECHNICAL MANUAL C 5300 CV/06-00 GB GB The information contained in this document may be modified without prior notice and is in no way binding, even implicitly, for CLIMAVENETA.
More informationRack & Enclosure Systems
Knürr CoolTherm 4 35 KW Energy-efficient Server Cabinet Technology With Outstanding Benefits, To Minimize Energy Costs In The Data Center And Help Reduce Carbon Dioxide Emmisions Rack & Enclosure Systems
More informationCONDENSING UNITS UASL- JEC
FORM NO. A22-196 3 Supersedes Form No. A22-196 Rev. 2 CONDENSING UNITS Equipped with Comfort Control 2 System Serial communication enabled Increased system reliability and efficiency 32+ on-board diagnostic
More informationpco sistema programmable controllers Technology & Evolution
pco sistema programmable controllers Technology & Evolution pco sistema programmable controllers The pco Sistema is the result of Carel s years of experience in the design and manufacture of programmable
More informationMin. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,
ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) SXT+ Product Specifications HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208
More informationMAKING MODERN LIVING POSSIBLE. ADAP-KOOL Drive. A New Drive for Energy Efficiency AKD 102 REFRIGERATION & AIR CONDITIONING DIVISION
MAKING MODERN LIVING POSSIBLE REFRIGERATION & AIR CONDITIONING DIVISION ADAP-KOOL Drive A New Drive for Energy Efficiency AKD 102 2 The AKD 102 comes with a common user interface and covers power ratings
More informationLiquid Cooling Package LCP Cooling Systems
Liquid Cooling Package LCP Cooling Systems 2 Rittal LCP Rittal The System. The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative
More information7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America
7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer
More informationLiebert. PDX from 15 to 165 kw. Direct Expansion Solution for Small and Medium Data Centers
Liebert PDX from 5 to 65 Direct Expansion Solution for Small and Medium Data Centers LIEBERT PDX from 5 to 65 Vertiv Vertiv designs, builds and services mission critical technologies that enable the vital
More informationData Center Optimized Controls
Data Center Optimized Controls Controls Agenda 30 min. Emerson Control Products icom (Dynamic Thermal Optimization) 20 min. Station Rotation Station 1: Controller Challenge Station 2: Wireless Demo 5 min.
More informationMOLLIER DIAGRAM CAN BE IMPROVED!
MOLLIER DIAGRAM CAN BE IMPROVED! IMPROVED BASIC COOLING CIRCUIT PERFORMANCE EFFICIENCY USING AN ECONOMISER Eng. Jonny Malachi, VP Operations, Mashav Refrigeration and Air Conditioning Engineering Ltd.
More informationT66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management
T66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management Name Doug Demian Title Application Engineer Date November 7 & 8, 2012 Rev 5058-CO900C Copyright 2012 Rockwell
More informationInPac 600 Series Fully configurable severe duty and explosion proof HVAC and building pressurization systems 2 5 ton ::
Fully configurable severe duty and explosion proof HVAC and building pressurization systems 2 5 ton :: 7.0 17.5 kw Features and Benefits Built for critical applications Two-stages of cooling allows for
More informationLiebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability
Liebert AFC from 500 to 1450 kw The Adiabatic Freecooling Solution with Top-Tier Availability Liebert AFC, the Ideal Adiabatic Chilled Water Solution for Top-Tier Data Centers Emerson Network Power delivers
More informationEcotel Free Cool 5-15kW
Precision Air Conditioning Free-cooling Ecotel Free Cool 5-15kW + + Self-contained compact outdoor cabin cooler + + 100% free-cooling + + -48V DC supply option + + Easy serviceability (front component
More informationIT Air Conditioning Units
IT Air Conditioning Units Modern Flexible Effective Energy Saving CoolTeg Plus and CoolTop overview CoolTeg Plus CW CoolTeg Plus DX CoolTeg Plus XC CoolTop Installation Between IT racks On top of IT rack
More informationMagnitude magnetic bearing centrifugal chillers
Magnitude magnetic bearing centrifugal chillers 75-1500 tons Better Air, Better Outcomes Magnitude magnetic bearing centrifugal chillers deliver the energy savings that building owners demand under all
More informationHIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT
ENVIRONMENTALLY SOUND REFRIGERANT H4A4 DX 1400 Product Specifications HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1-phase, 60 Hz
More informationJ&M Fluidics, Inc. Company Product Overview
It s All about Building a Better Product for Our Clients! J&M Fluidics, Inc. Company Product Overview J&M Fluidics, Manufacturer of Air & Water-Cooled Process Chillers. Located in Telford, Pennsylvania
More information1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES
INDOOR COILS PRODUCT SPECIFICATIONS Horizontal Bulletin No. 20667 November 206 Supersedes August 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION CH 35-8 A - 2 F Unit Type CH = Indoor - Horizontal Series Nominal
More informationDatasheet.
Industrial Test & Mixing Equipment Bringing Test Innovation to you Datasheet This product datasheet has been provided by John Godrich & SJ Electronics in Partnership with BINDER www.johngodrich.co.uk www.sjelectronics.co.uk
More informationMGE Galaxy /900 kva
MGE Galaxy 9000 800/900 kva Data centers are becoming increasingly large, Blade Servers are demanding more power, and there is increasing demand from semi conductors for the digital economy. The MGE Galaxy
More informationLiebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability
Liebert AFC from 500 to 1450 kw The Adiabatic Freecooling Solution with Top-Tier Availability Liebert AFC, the Ideal Adiabatic Chilled Water Solution for Top-Tier Data Centers Emerson Network Power delivers
More information