Preliminary. Compact Global Modem Board
|
|
- Clarence Stewart
- 6 years ago
- Views:
Transcription
1 Preliminary XE5620SM February 2003 Compact Global Modem Board Description Xecom s XE5620SM is a complete modem on a compact PCB (daughter board). Xecom includes transferable FCC Part 68 Registration to the user of the XE5620SM. This allows the embedded system designer to easily add modem communications to his process control, remote monitoring, point-of-sale, or remote diagnostic system without additional FCC testing. Xecom s XE5620SM has a twenty percent smaller footprint than other modem daughter board products. This reduced footprint saves board space and allows the design engineer greater flexibility in placement of the modem within the host system. A variation of the XE5620SM, the XE5620SM-F, incorporates Flash memory onto the daughter board. The presence of Flash memory allows future updating of the modem code when features are added. Features * Small Size: by 1.00 by 0.3 * Data transfer at rates from 300 bps to 56 kbps using V.90, V.34bis, V.34, V.32bis, V.32, V.22bis, V.22, V.23, V.21, Bell 212A, and Bell 103 Protocols * Modem Control and Configuration via industry standard AT Commands. * Supports V.42 error correction and V.42bis data compression. * Nonvolatile memory stores modem configuration and permits stored number dialing. * Incorporates Fax send and receive capabilities controlled by Class 1 Fax commands. * Complete integrated DAA. * User Transferrable FCC Part 68 Registration * Complies with telephone networks around the world. * UL60950 Recognition * Low Power operation, 3.3 Volts, 300 milliwatts; XE5620SM/XE5620SM-F BLOCK DIAGRAM NVRAM Reset /TXD /RXD /RTS /DSR /DCD /CTS /DTR /RI Modem Controller ROM or Flash (XE5620SM-F) Analog Front End Global Telephone Line Interface (DAA) Tip Ring SPKR XECOM (1) XE5620SM
2 XE5620SM Mechanical Specifications a l h j k e g d (Top View) b f k j m j n k c Inches Millimeters Dimension Min Typ Max Min Typ Max a b c d e f g h j k l m n Note: All pins are.025 square XECOM (2) XE5620SM
3 XE5620SM Pin Configuration Top View Tip Ring VCC 14 /DCD 13 /CTS 12 /DSR 11 /RTS EXM 3 10 /RXD /Reset 4 9 /TXD SPKR 5 8 /DTR Gnd 6 7 /RI Pin Descriptions PIN NAME DESCRIPTION 1 Tip The Ring and Tip signals connect the modem to the telephone line. FCC Part 68 Rules require a 1500 volt isolation barrier between the telephone line and all other circuits. This isolation must be preserved throughout the system. The telephone company places a DC Battery voltage across Tip and Ring on public switched telephone lines. The XE5620SM operates regardless of the polarity of this Battery voltage. The Battery voltage drives up to 100 milliampere of DC loop current. UL60950 requires minimum creepage and clearances distances between the Tip and Ring traces and all other circuits. Clearance is the shortest distance between conductive circuits; creepage is the distance between conductive points along the surface 2 Ring The Ring and Tip signals connect the modem to the telephone line. FCC Part 68 Rules require a 1500 volt isolation barrier between the telephone line and all other circuits. This isolation must be preserved throughout the system. The telephone company places a DC Battery voltage across Tip and Ring on public switched telephone lines. The XE5620SM operates regardless of the polarity of this Battery voltage. The Battery voltage drives up to 100 milliampere of DC loop current. XECOM (3) XE5620SM
4 XE5620SM Pin Descriptions (continued) PIN NAME DESCRIPTION UL60950 requires minimum creepage and clearances distances between the Tip and Ring traces and all other circuits. Clearance is the shortest distance between conductive circuits; creepage is the distance between conductive points along the surface. 3 EXM EXM will be high when Flash memory is used, XE5620SM-F. Do not attach any signal to this pin. 4 RESET RESET is an active low input which initiates a modem hardware reset. RESET must be active for a minimum of 100 milliseconds for a proper modem reset sequence. No external reset is required; if none is used the RESET signal should be left open. 5 SPKR SPKR allows connection of a speaker to monitor modem operations. SPKR cannot directly drive a speaker; an amplifier with a minimum input impedance of 300 ohms is required. The signal on SPKR is controlled by the ATL and ATM commands. 6 Ground Ground provides the reference voltage for all host interface signals. 7 /RI The /RI signal reports on the presence of an incoming ring signal. When a ring occurs across Tip and Ring, the /RI output goes low and toggles with the cadence of the ring signal.. 8 /DTR /DTR is an active low input to the modem. An active /DTR signals the terminal is available for communications. The AT&D command determines how the modem interprets activity on /DTR. 9 /TXD /TXD provides the path for transmitted data and modem commands to be passed from the host controller to the modem. 10 /RXD /RXD provides the path for received data and modem responses to be sent from the modem to the host controller. 11 /RTS /RTS is an active low input to the modem. When hardware flow control is set, ab active /RTS indicates to the modem that the host has data to send. 12 /DSR /DSR is an active low output from the modem. An active /DSR indicates the modem link is established. The AT&S command controls when the XE5620SM asserts /DSR. 13 /CTS /CTS is an active low output from the modem. When hardware flow control is set, the modem asserts /CTS to indicate that it can accept data from the terminal equipment on /TXD. 14 /DCD /DCD is an active low output from the modem. An active /DCD indicates the presence of a valid carrier signal. The AT&C command controls when the XE5620SM asserts /DCD. 15 VCC VCC provides 3.3 volt power to the modem. XECOM (4) XE5620SM
5 XE5620SM Electrical Specifications Parameter Min Typ Max Units Comments VCC Volts ICC ma On Line ICC 25 ma On-Hook Ring Voltage Detected VRMS Type B Ringer Ring Frequency Detected Hz Type B Ringer Telephone Loop Current ma Line Impedance 600 Ohms Data Transmit level dbm DTMF Transmit Level dbm Avg over 3 second interval Voh 2.4 Volts Vol 0.4 Volts Vih 2.0 VCC+0.3 Volts Vil Volts XE5620SM ABSOLUTE MAXIMUM RATINGS Storage Temperature -25 O C to +85 O C 1 Maximum Operating Temperature Range 0 O C to +70 O C Maximum Time Above Eutectic (183 O C) Preheat Dwell Time 90 seconds 120 to 180 seconds 1 The XE5620SM can be ordered with an Operating Temperature of -40 O C to +85 O C at extra cost. Order XE5620SM-ITR or to specify Industrial Temperature Range (ITR). XECOM (5) XE5620SM
6 XE5620SM Typical Connection Diagram VCC XE5620SM TIP (1) FB1 F1 RJ11 Ring (2) FB2 F2 C1 C2 VCC (15) /DCD (14) /CTS (13) /DSR (12) VCC To Host Serial Port /RTS (11) /RXD (10) /TXD (9) /DTR (8) /RI (7) EXM (3) /RESET (4) SPKR (5) Gnd (6) C3 R U C4 C5 LS1 R2 Parts List for XE5620SM Typical Connection Diagram Reference Reference Designation Qty Description Designation Qty Description C1, C2 2 Cap. 470 pfd 2600V U1 1 National Semi LM386 C3, C4 2 Cap. 0.1 ufd 20% 16V LS1 1 Speaker, 8 Ohms C5 1 Cap. 100 ufd 20% 10V R1 1 Potentiometer, 10K FB1, FB2 2 Ferrite, TDK ACB2012L-120 R2 1 Resistor, 10 Ohms 20 % F1, F2 2 PTC, TR Notes: 1 FB1 and FB2 are ferrite beads which may be required for EMI filtering in your system. Without these components you may experience unintended radiation when the telephone cable is attached. We recommend selecting components such as the TDK ACB2012L-120 which provide a minimum of 100 ohms of impedance at frequencies above 100 MHz. 2. C1 and C2 are high-voltage capacitors which may be required for EMI filtering in your system. Without these components you may experience unintended radiation when the telephone cable is attached to your system. We recommend selecting components such as the Panasonic ECKDRS471. This 470 pfd, 3000 volt capacitor will direct the high frequency harmonics to the system ground. These capacitors must be rated at a minimum of 1500 volts to maintain the isolation required by FCC Part 68 Rules. 3. F1 and F2 are positive thermal coefficient (PTC) devices which protect the modem form excessive current flow. These devices are required for your system to pass UL Fuses may be used in place of the PTC s XECOM (6) XE5620SM
7 Country Selection Xecom has designed the XE5620SM to function in a wide variety of countries throughout the world. Below is a list of the available country configurations. Please contact Xecom if you have questions regarding a country not on this list. Countries Supported: COUNTRY Australia Austria Belgium Czech Republic Denmark Finland France Germany Greece Holland Iceland India Ireland Italy Japan AT COMMAND AT*NC40 AT*NC1 AT*NC2 AT*NC19 AT*NC3 AT*NC4 AT*NC5 AT*NC6 AT*NC17 AT*NC10 AT*NC28 AT*NC18 AT*NC7 AT*NC8 AT*NC43 COUNTRY Lichtenstein Luxembourg Namibia Norway Poland Portugal Russia South Africa Spain Sweden Switzerland Taiwan United Kingdom United States AT COMMAND AT*NC29 AT*NC9 AT*NC26 AT*NC11 AT*NC24 AT*NC12 AT*NC25 AT*NC27 AT*NC13 AT*NC14 AT*NC15 AT*NC20 AT*NC16 AT*NC22 NOTE: Country regulations permit Xecom to offer transferrable registration only in the United States, FCC Part 68 only. All other required certifications of systems using the XE5620SM are the responsibility of Xecom s customer. Xecom will assist our customers with any of these certifications. XECOM (7) XE5620SM
8 XE5620SM AT Commands The XE5620SM uses "AT" commands for configuration and control. This section describes the AT command format and lists the AT commands, Registers and Result codes. XE5620SM "AT" commands have two operational modes; Command Mode, Data Mode and FAX mode. Data Mode: The XE5620SM enters data mode after it connects to a remote modem and issues the appropriate result code. In the Data Mode the modem sends all data presented on Transmit Data (/TXD) to the remote modem and puts data from the remote modem onto Received Data (/RXD). When the modem exits data mode, it issues a "NO CARRIER" result code. Command Mode: The XE5620SM enters command mode on power-up, reset, a lost connection, or receipt of the escape code. In command mode the modem accepts commands from the host on transmit data. Appropriate result codes are returned on received data. Fax Mode: The XE5620SM enters Class 1 fax mode on receipt of AT+FCLASS=1. In fax mode commands and responses are issued at 19,200 bits per second; the character format is 8 bits no parity. The modem accepts fax commands only in fax mode. The A/, ATO, AT&T and escape commands are not valid in fax mode. Command Line Format Command lines issued to the modem follow a strict format. Each command begins with the prefix AT. The command buffer stores the command line and executes it upon receipt of a carriage return. Until executed, the command line can be edited with the backspace key. Command Prefix - Each command, except the A/ command, begins with the AT prefix. The "A" and "T" may be both upper case or both lower case but cannot be of different cases. The prefix identifies the speed and parity of the commands sent to the modem. The modem determines data rate by measuring the width of the incoming bits. Parity is determined by comparing the parity bits of the "A" and the "T." Command Line - Commands may be strung together in a single command line of up to 36 characters. Commands are executed in the sequence they appear. Spaces may be inserted into the command line but do not fill space in the command buffer. A carriage return terminates the command line and causes the commands to be executed. Register S3 allows the user to select a character other than a carriage return to terminate the command line. Command Buffer - The Command Buffer holds a maximum of 36 characters, including the AT prefix. If the command buffer overflows, the modem issues an "ERROR" result code and commands are not executed. Command Line Editing - The backspace edits a command line before it is executed. The backspace key, (Control and H simultaneously on some systems), erases the previous character in the command line. Register S5 allows the user to select a character other than a backspace to edit the command line. Re-Execute Last Command - The A/ command causes the modem to re-execute the last command line. This is the only command which does not require the "AT" prefix. Omitted Parameters - Most commands include a parameter which determines how the functions will be set. When the command parameter is omitted from the command string, it is assumed to be a 0. Escape Characters - A 3 character escape sequence may be entered to switch the modem into command mode while on line. The escape character, set by Register S2, must be entered 3 times in succession to execute the escape. An AT command must then be entered within the period defined by S12 to enter command mode. The default escape sequence is "+++." Result Codes - The modem issues a result code after each action. Result codes may be sent as full words, one or two digit numeric codes, or may be disabled all together. Each result code ends with a carriage return when numeric result codes are chosen. When full word result codes are chosen, a Line Feed and Carriage Return precede and follow each result code. XECOM (8) XE5620SM
9 XE5620SM AT Commands An asterisk indicates the factory default A - Answer Command - Bn - Select Communications Standard n=0 Selects CCITT standards * n=1 Selects Bell standards D - Dial Command - 0-9, A-D, #, * = Dialing Digits P = Pulse dial T = Tone dial W = Wait for dial tone, = Pause for the duration of = Wait for silence! = Switch hook flash ; = Return to the command state ^ = Enable Calling Tone S=n = Dial Stored Number n En - Command Echo n=0 Do not echo commands n=1 Enable command echo* Hn - Switch Hook Control - n=0 Switch hook relay opens n=1 Switch hook relay closes In - Modem Identification Ln - Speaker Volume - n=0 Speaker volume low n=1 Speaker volume low n=2 Speaker volume medium * n=3 Speaker volume high. Mn - Speaker Activity - n=0 Speaker off n=1 Speaker on until carrier received* n=2 Speaker remains on n=3 Speaker on after dialing until DCD detected. Nn - Modulation Selection n=0 Communication Rate set by AT*I Command n=1 Automatic Negotiation of Data Rate beginning at AT*I Setting. * On - On Line n=0 Return On Line with no retrain* n=1 Initiate retrain while returning On line. n=2 Initiate rate renegotiation while returning On line. Qn - Responses n=0 Send responses * n=1 No Responses Sr? - Interrogate Register - Sr=n - Set Register Value - Vn - Result Codes - n=0 Numeric Result Codes n=1 English Word Result Codes* Wn - CONNECT Result Code - n=0 Display CONNECT DCE Speed n=1 Display CONNECT DTE Speed n=2 Display CONNECT DCE Speed plus error control extension * n=3 Display CONNECT DTE Speed plus error control extension Xn - Result Code Set - n=0 Responses 0-4 n=1 Responses 0-5 & 10 n=2 Responses 0-6 & 10 n=3 Responses 0-5, 7 & 10 n=4 Responses 0-7 & 10* Zn - Reset - n=0 Reset and Recall Profile 0 * n=1 Reset and Recall Profile 1 &Cn - DCD Operation n=0 DCD is forced active n=1 DCD indicates a valid carrier signal * &Dn - DTR n=0 DTR is ignored n=1 When the modem is on-line DTR off switches it to the command mode and issues OK response. n=2 Modem disconnects if the host revokes DTR.* n=3 The modem performs a soft reset when DTR is revoked. &F - Reset Factory Defaults &Gn - Guard Timer - n=0 None * n=1 550 Hz Guard Timer n= Hz Guard Timer XECOM (9) XE5620SM
10 XE5620SM AT Commands &Kn - Flow Control n=3 RTS/CTS Flow Control * n=4 XON/XOFF Flow Control &Pn - Pulse Dial Make/Break Ratio n=0 39%/61% 10 PPS * n=1 33%/67% 10 PPS n=2 39%/61% 20 PPS n=3 33%/67% 20 PPS &Rn - Clear to Send n=0 Clear to Send follows Request to Send n=1 Clear to Send Active * &Sn - Data Set Ready n=0 Data Set Ready Forced Active * n=1 Data Set Ready on at Start of Modem handshake &Un - Protocol Selection n=0 V.90 * n=1 V.34Bis/V.34 n=2 V.32bis/V.22bis n=3 Bell 103 n=4 V.21 n=5 V.23 &V - View Active Configuration &Wn - Store Current Configuration n=0 Store Active Configuration in Profile 0 * n=1 Store Active Configuration in Profile 1 &Yn - Select Configuration to Recall n=0 Recall Configuration Profile 0 * n=1 Recall Configuration Profile 1 &Zn=x - Store dialing string x %Cn - Data Compression Control n=0 No Data Compression n=1 Data Compression Enabled * \Nn - Error Control Mode n=0 Normal Mode n=1 Direct Mode n=2 MNP Required n=3 MNP or Normal n=4 Auto Error Correction V.42 without ODP or ADP Phase Detection, MNP or Normal mode n=5 Auto Reliable Mode * n=6 V.42 without ODP or ADP Phase Detection required n=7 V.42 with ODP or ADP Phase Detection required \Vn - Protocol Result Code n=0 No Protocol Result code added to Response * n=1 Protocol Result code added to Response *Hn - Automatic Retrain n=0 Automatic Retrain Disabled n=1 Automatically retrain on poor signal quality *In - Select Maximum Connection Speed n= bps, n= bps, 28,000 with AT&U=0 n= bps, 29,333 with AT&U=0 n= bps, 30,666 with AT&U=0 n= bps, 32,000 with AT&U=0 n=5 12,000 bps, 33,333 with AT&U=0 n=6 14,400 bps, 34,666 with AT&U=0 n=7 16,800 bps, 36,000 with AT&U=0 n=8 19,200 bps, 37,333 with AT&U=0 n=9 21,600 bps, 38,666 with AT&U=0 n=10 24,000 bps, 40,000 with AT&U=0 n=11 26,400 bps, 41,333 with AT&U=0 n=12 28,800 bps, 42,666 with AT&U=0 n=13 31,200 bps, 44,000 with AT&U=0 n=14 33,600 bps *, 45,333 with AT&U=0 n=15 46,666 bps with AT&U=0 n=16 48,000 bps with AT&U=0 n=17 49,333 bps with AT&U=0 n=18 50,666 bps with AT&U=0 n=19 52,000 bps with AT&U=0 n=20 53,333 bps with AT&U=0 n=21 54,666 bps with AT&U=0 n=22 56,000 bps with AT&U=0 * XECOM (10) XE5620SM
11 XE5620SM AT Commands *NCn - Country Configuration n=1 Austria n=2 Belgium n=3 Denmark n=4 Finland n=5 France n=6 Germany n=7 Ireland n=8 Italy n=9 Luxembourg n=10 Holland n=11 Norway n=12 Portugal n=13 Spain n=14 Sweden n=15 Switzerland n=16 United Kingdom n=17 Greece n=18 India n=19 Czech Republic n=20 Taiwan n=21 reserved n=22 United States n=23 reserved n=24 Poland n=25 Russia n=26 Namibia n=27 South Africa n=28 Iceland n=29 Liechtenstein n=30 reserved n=31 reserved n=32 reserved n=33 reserved n=34 reserved n=35 reserved n=36 reserved n=37 reserved n=38 reserved n=39 reserved n=40 Australia *On - Transmit Level Selection (Note: This feature is not available in all country configurations.) n=0-11 dbm (default) n=1-12 dbm n=2-13 dbm n=3-14 dbm n=4-15 dbm n=5-16 dbm n=6-17 dbm n=7-18 dbm n=8-19 dbm n=9-20 dbm n=10-21 dbm n=11-22 dbm n=12-23 dbm n=13-24 dbm n=14-25 dbm n=15-26 dbm XECOM (11) XE5620SM
12 XE5620SM AT Class 1 FAX Commands AT+FCLASS? - Service Class Indication 0 = Configured as a data modem 1 = Configured for Service Class 1. AT+FCLASS=? - Service Class Capability 0 = Configured as a data modem 1 = Configured for Service Class 1. AT+FCLASS=n - Set Service Class 0 = Configured as a data modem 1 = Configured for Service Class 1. AT+FAE=n - Data/Fax Auto Answer 0 = Answer as a fax modem only 1 = Either a fax or data modem AT+FLO - Flow Control 0 = Flow Control Off 1 = XON/XOFF Flow Control Selected 2 = RTS/CTS Flow Control Selected * AT+FRH<mod> - Receive HDLC Data 3 V.21 Channel 2, 300 bps 24 V.27ter, 2400 bps 48 V.27ter, 4800 bps 72 V.29, 7200 bps 96 V.29, 9600 bps 97 V.17, 9600 bps 98 V.17 short train, 9600 bps 121 V.17, 12,000 bps 122 V.17 short train, 12,000 bps 145 V.17, 14,400 bps 146 V.17 short train, 14,400 bps AT+FRM<mod> - Receive Fax (see AT+FRH for "mod" values) AT+FRS<time> - Receive Silence AT+FRTn - Receive Test Data AT+FTH<mod> - Transmit HDLC Data (see AT+FRH for "mod" values) AT+FTM<mod> - Transmit Fax (see AT+FRH for "mod" values) AT+FTS<time> - Transmit Silence AT+FTTn - Transmit Test Data XECOM (12) XE5620SM
13 XE5620SM Modem Registers S0 S1 S2 S3 S4 S5 S6 Answer on nth Ring: S0 sets the modem to automatically answer on the nth ring. Setting S0 to 0 disables automatic answer. Range: 0 to 255 Units Rings Default 0 Ring Count: S1 is a read-only register showing the number of rings detected. If a ring is not detected within 8 seconds, S1 is reset to zero. Range: 0 to 255 Units Rings Default 0 Escape Character: S2 determines the ASCII escape character. Values of select valid characters; values from 128 to 255 disable the escape sequence. Range: 0 to 255 Units ASCII Character Default 43 (+) Line Termination Character: S3 determines the ASCII character which will terminate commands and modem responses. Range: 0 to 127 Units ASCII Character Default 13 (Carriage Return) Line Feed Character: S4 sets the ASCII character to act as a line feed character in modem responses. Range: 0 to 127 Units ASCII Character Default 10 (Line Feed) Backspace Character: S5 defines the ASCII character used as a backspace to edit the command line. Range: 0 to 127 Units ASCII Character Default 8 (Back Space) Dial Tone Wait Time: S6 determines how long the modem waits for dial tone before dialing. The Dial Tone Wait Time cannot be set to less than two seconds. Range: 3 to 7 Units Seconds Default 6 S7 S8 S9 S10 S11 S12 S13 Wait for Carrier after Dialing: S7 determines how long the modem waits for a valid carrier signal after dialing. Range: 1 to 255 Units Seconds Default 60 Comma Pause Time: S8 defines the duration of the pause initiated by a comma in the dialing string. The pause is generally used when waiting for a second dial tone. Range: 1 to 255 Units Seconds Default 2 Carrier Detect Response Time: S9 establishes the length of time the remote modem's carrier must be present to be recognized as valid. Range: 1 to 255 Units 0.1 Seconds Default 6 Carrier Off Disconnect Delay: S10 selects how long carrier must be lost before the modem disconnects. Note: If S10 is smaller than the value of S9 or S10 is set to 255, the modem will not automatically disconnect on loss of carrier. Range: 1 to 255 Units 0.1 Seconds Default 14 Tone Dialing Speed: S11 sets the duration and spacing of the dialing tones. S11 does not affect the pulse dialing. Range: 50 to 255 Units 1 Millisecond Default 95 Escape Code Guard Timer: S12 sets the escape sequence guard timer. If characters are received before or after the escape sequence, within the guard timer, the modem aborts the escape attempt and remains in data mode. Range: 0 to 255 Units 0.02 Seconds Default 50 Pulse Dialing : S13 permits pulse dialing to be disabled Register Setting Function 0 No Pulse Dialing 1 Pulse Dialing Allowed XECOM (13) XE5620SM
14 XE5620SM Modem Registers (continued) S14 S21 S22 Bit-mapped Register: S14 stores the values of Several AT Commands. Bit Function 0 Echo (ATE0) 1 Reserved 2 Result Codes (ATQ0) 3 Numeric Responses (ATV0) 4,5 Pulse Dialing Parameters (AT&P0) Bit-mapped Register: S21 stores the values of Several AT Commands. Bit Function 0-2 Reserved 3,4 DTR Condition (AT&D) 5 DCD Function (AT&C) 6 DSR Function (AT&S) 7 Reserved Bit-mapped Register: S22 stores the values of Several AT Commands. Bit Function 0-3 Speaker Control (ATL/ATM) 4,5,6 Response Set (ATX) 7 Reserved S95 S97 S98 Bit-mapped Register: S95 stores the modem s result code and modulation information. Bit Function 0, 1, 2 Result Code Selection 3 Modulation Selection 4-7 Reserved Bit-mapped Register: S97 stores the modem s error control and data compression information. Bit Function 0-2 Error Correction Selection 3-6 Reserved 7 Data Compression Selection Bit-mapped Register: S98 stores the automatic retrain and Flow control status. Bit Function 0, 1 Error Correction Selection 2, 3 Reserved 4-6 Flow Control Selection 7 Reserved S23 Bit-mapped Register: S23 stores the modem s active data format. Bit Function 0, 1,2,3 DTE Rate BPS 4,5 Parity 6,7 Reserved S30 Inactivity Timer: S30 determines how long the modem will remain on line with not data flowing. A 0 in this register disables the inactivity time out. Range: Units Minutes Default 0 XECOM (14) XE5620SM
15 XE5620SM Modem Responses Digits Verbose Description 0 OK Command Successful 1 CONNECT 300 bps connection 2 RING Ring signal detected 3 NO CARRIER Carrier not detected 4 ERROr Error in command line 5 CONNECT BPS Connection 6 NO DIAL TONE No dial tone detected 7 BUSY Busy signal detected 8 NO ANSWER No 5 sec. silence detected 9 CONNECT bps Connection 10 CONNECT bps Connection 11 CONNECT bps Connection 12 CONNECT bps Connection 13 CONNECT bps Connection 14 CONNECT ,000 bps Connection 15 CONNECT ,800 bps Connection 16 CONNECT ,200 bps Connection 17 CONNECT ,600 bps Connection 20 CONNECT ,400 bps Connection 21 CONNECT ,000 bps Connection 22 CONNECT ,400 bps Connection 23 CONNECT ,600 BPS Connection 24 CONNECT ,200 BPS Connection Digits Verbose Description 30 CONNECT ,400 bps Connection 31 CONNECT ,800 bps Connection 32 CONNECT ,200 bps Connection 33 CONNECT ,600 bps Connection 34 CONNECT V.90 28,000 bps Connection 35 CONNECT V.90 29,333 bps Connection 36 CONNECT V.90 30,666 bps Connection 37 CONNECT V.90 32,000 bps Connection 38 CONNECT V.90 33,333 bps Connection 39 CONNECT V.90 34,666 bps Connection 40 CONNECT V.90 36,000 bps Connection 41 CONNECT V.90 37,333 bps Connection 42 CONNECT V.90 38,666 bps Connection 43 CONNECT V.90 40,000 bps Connection 44 CONNECT V.90 41,333 bps Connection 45 CONNECT V.90 42,666 bps Connection 46 CONNECT V.90 44,000 bps Connection 47 CONNECT V.90 45,333 bps Connection 48 CONNECT V.90 46,666 bps Connection 49 CONNECT V.90 48,000 bps Connection 50 CONNECT V.90 49,333 bps Connection 51 CONNECT V.90 50,666 bps Connection 52 CONNECT V.90 52,000 bps Connection 25CONNECT1200TX/75RX V.23 Connection 1200 bps Transmit 75 bps Receive 53 CONNECT V.90 53,333 bps Connection 54 CONNECT V.90 54,666 bps Connection 26CONNECT75TX/1200RX V.23 Connection 75 bps Transmit 1200 bps Receive 55 CONNECT V.90 56,000 bps Connection 28 CONNECT BELL 300 Bell 300 bps Connection 29 CONNECT V21 V bps Connection XECOM (15) XE5620SM
16 FCC Instructions The XE5620SM complies with part 68 of the FCC Rules and Regulations. With each device shipped, there is a label which contains, among other information, the FCC Registration Number and Ringer Equivalence Number (REN) for this product. You must, upon request, provide this information to your telephone company. The mounting of this device in the final assembly must be made in such a manner as to preserve the high voltage protection between the TIP/RING Connection and the rest of the system. Typically, this may be accomplished by maintaining a minimum spacing 100 mils between the TIP/RING Traces to the RJ-11C Jack and low voltage portion of the system. No additional circuitry may be attached between TIP/RING and the telephone line connection, unless specifically allowed in the rules. The REN is useful to determine the quantity of devices you may connect to a telephone line and still have all of these devices ring when the number is called. In most, but not all areas, the sum of the RENs of all devices connected to one line should not exceed five (5.0). To be certain of the number of devices you may connect to the line, as determined by the REN, you should contact the local telephone company to determine the maximum REN for you calling area. If your system causes harm to the telephone network, the telephone company may discontinue service temporarily. If possible, they will notify you in advance. If advance notification is not practical, you will be notified as soon as possible. Your telephone company may make changes in its facilities, equipment, operations or procedures that could affect proper functioning of your equipment. If they do, you will be notified in advance to give you an opportunity to maintain uninterrupted telephone service. If you experience trouble with this device, please contact XECOM at (408) for information on obtaining service or repairs. The telephone company may ask you to disconnect this device from the network until the problem has been corrected or until you are sure that the device is not malfunctioning. The device may not be used on coin service lines provided by the telephone company (this does not apply to private coin telephone applications which use standard telephone lines). Connection to party lines is subject to state tariffs. XECOM (16) XE5620SM
17 Terms of Sale Devices sold by XECOM are covered by the warranty provisions appearing in its Terms of Sale only. XECOM makes no warranty, express, statutory, implied, or by description regarding the information set forth herein, or regarding the freedom of the described devices from patent infringement. XECOM makes no warranty of merchantability or fitness for any purposes. XECOM reserves the right to discontinue production and change specifications and prices at any time and without notice. This product is intended for use in normal commercial applications. Applications requiring extended temperature range, unusual environmental requirements, or high reliability applications, such as military, medical life-support or life-sustaining equipment, are specifically not recommended without additional processing and authorization by XECOM for such application. Xecom assumes no responsibility for the use of any circuitry other than circuitry embodied in a Xecom product. No other circuits, patents, or licenses are implied. Life Support Policy Xecom's products are not authorized for use as Critical Components in Life Support Devices or Systems. Life Support Devices or Systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform, when properly used in accordance with instructions provided in the labeling, can be reasonably expected to result in significant injury to the user. A Critical Component is any component of a life support device or system whose failure to perform can be reasonably expected to cause failure of the life support device or system, or to affect its safety or effectiveness. Copyright, Xecom 2003 While Xecom, Inc. has made every effort to ensure that the information presented here is accurate, Xecom will not be liable for any damages arising from errors or omission of fact. Xecom reserves the right to modify specifications and/or prices without notice. Product mentioned herein are used for identification purposes only and may be trademarks and/or registered trademarks of their respective companies. Xecom Incorporated 374 Turquoise Street, Milpitas, CA Ph: Fax: info@xecom.com XECOM (17) XE5620SM
xecom XE2486 Miniature 2400 bps Modem Module Description Features Block Diagram VCC Serial I/O ROM NVRAM Modem Controller Auxilliary I/O Tip
xecom Miniature 2400 bps Modem Module XE2486 8-97 Description Xecom's XE2486 is a miniature, low cost 2400 bit per second modem. It provides a complete modem, including necessary memory and the DAA in
More informationGlobal 56KBPS Modem in XExx14L Pin Out XE5614G BLOCK DIAGRAM
Preliminary XE5614G November 2004 Global 56KBPS Modem in XExx14L Pin Out Description Xecom's XE5614G brings Global connectivity to Xecom s XExx14L modem family. This permits existing designs which use
More informationLow Speed Modems for Dial and Leased Circuits 2400E (Standalone) 2400R (Rackmount)
Low Speed Modems for Dial and Leased Circuits 2400E-030-4 (Standalone) 2400R-030-4 (Rackmount) QUALITY COMMUNICATIONS PRODUCTS Made in the U.S.A. 11-1010-002 INTRODUCTION The Data Connect ST2400E-2 and
More informationRTU-COM PSTN AT. User Guide
1 RTU-COM PSTN AT User Guide V. 1.00 / Feb 2006 / Doc 40142 2 1. Introduction This document is a guide for change settings in the PSTN modem integrated in the RTU-COM. You have only access to change the
More informationAT Commands - Trust 56K PCI Modem - Executing commands
AT Commands - Trust 56K PCI Modem - www.trust.com/11709 Executing commands Your modem is in Command Mode upon power-on and is ready to receive and execute AT commands. The modem remains in Command Mode
More informationARC Modem Low Power Modem LP9624
Over a decade of service to the Data Commination Industry 800-926-0226 / 281-392-6333 ARC Modem Low Power Modem LP9624 After 5 seconds of inactivity, the unit automatically goes into power down mode The
More informationXE24S100 Block Diagram
XE24S100 June 2006 Xecom XE24S100 the Smallest, Complete 2.4 GHZ FHSS Transceiver Description The Xecom XE24S100 is a miniature 2.4 GHz Spread Spectrum transceiver. It includes all RF hardware and a micro-controller
More informationx2 AT Command Reference for TelePort 56 modems
x2 AT Command Reference for TelePort 56 modems Copyright 1997 Global Village Communication, Inc., and its Licensors. Portions Copyright 1989 1996, Thought Communications, Inc. All rights reserved. Fax
More informationZM24x Quick-Connect Industrial Modem. User s Manual
ZM24x Quick-Connect Industrial Modem User s Manual Version 1.1 2004 ZYPEX, Inc. All Rights Reserved 1 ZM24x Quick-Connect Industrial Modem Since the equipment explained in this manual has a variety of
More informationx2 COMMANDS & TECHNICAL REFERENCE
x2 COMMANDS & TECHNICAL REFERENCE NOTE: Until now, 33.6 Kbps was thought to be the practical limit for speed over standard phone lines. Now x2 technology shatters that barrier to bring you download speeds
More informationTelenetics dial modems are based upon Rockwell chipsets. These chipsets contain Rockwell's "AT" command set.
AT COMMAND SET and S-REGISTERS Telenetics dial modems are based upon Rockwell chipsets. These chipsets contain Rockwell's "AT" command set. A summary of the Rockwell command set for the PE2496 and PE14.4
More informationXE900S-500 Smart Spread Spectrum Transceiver. XE900S-500 Block Diagram
XE900S-500 June 2005 XE900S-500 Smart Spread Spectrum Transceiver Description The XE900S-500 combines a spread spectrum transceiver and micro-controller in a single, easy-touse, FCC Part 15 Registered
More informationPCMCIA Fax Modem 56K. User Manual
PCMCIA Fax Modem 56K User Manual FCC REGULATORY STATEMENTS FCC Part 68 Registration This device complies with FCC Part 68 rules, and the use of this device is subject to the following restrictions: 1.
More informationModem AT Command Set
Command Function Modem AT Command Set AT Attention - this precedes all commands except A/ and +++ A/ Execute previous command - does not require a A B0 B1 B2 D Dmn L W Causes the modem to go off hook.
More informationManual Reference. Modem Commands. S35i, C35i, M35i
Manual Modem s for the SIEMENS Mobile Phone S35i, C35i, M35i page 1 of 7 The command descriptions or example sequences in this document imply no liability or warranty in any way. The author therefore will
More informationRS K Ext Modem. User Manual
RS-232 56K Ext Modem User Manual Content 1. Introduction... 2 2. Features... 3 3. Installation... 4 3.2.1 Installation Procedures for Windows 64 bits (XP/Win7/Vista)... 6 3.2.2 Installation Procedures
More informationTP560i. TP560i 56Kbps Data/Fax/Voice Modem Chip Set PCI Bus Interface. User s Manual AT Command Set
TP560i 56Kbps Data/Fax/Voice Modem Chip Set PCI Bus Interface User s Manual AT Command Set Introduction This is a high performance ITU-V.90 56Kbps modem; Computer can make connection with remote terminal,
More informationSutron Voice Modem Operation Manual
Sutron Voice Modem Operation Manual Models: 8080-0005-1 and -2 TABLE OF CONTENTS Overview...1 Jumpers and Connections...2 Recommended Jumper Settings...2 Operation with the Xpert/Xlite...3 Operation with
More informationChapter 5 AT Commands
Chapter 5 AT Commands GENERAL This chapter describes commands used to select options and to operate the modem. Some options depend on or are restricted by the mode of operation. COMMAND CATEGORIES The
More informationZM56 High-Speed Industrial Modem. Command Summary. 1 ZM56 High-Speed Industrial Modem
ZM56 High-Speed Industrial Modem Command Summary 1 ZM56 High-Speed Industrial Modem AT Command Summary Command AT ATA ATDT ATE0 ATE1 ATH ATH1 ATI ATO ATS Description Attention Prefix Precedes all commands
More information4.3 Ingenico Telium OS modem specific commands
4.3 Ingenico Telium OS modem specific commands 4.3.1 Command: return to command mode Syntax : void esc_command (void) 4.4 AT Commands The AT commands are used to: C operational parameters, Establish a
More informationINSTALLATION MANUAL TD33/V.90 TD-33 TD33/V.90 US. Tele Modem V.90/K56flex or V Westermo Teleindustri AB 2001 REV. A. Galvanic Isolation
TD33/V.90 TD-33 TD33/V.90 US INSTALLATION MANUAL Galvanic Isolation 6179-2203 Transient Protection Balanced Transmission CE Approved Westermo Teleindustri AB 2001 REV. A Tele Modem V.90/K56flex or V.34
More informationCMM 900-3W USER GUIDE
CMM 900-3W USER GUIDE AMPS Cellular Modem Module (3W) Page 1 of 1 Table of Contents 1. PRODUCT OVERVIEW...3 1.1 Features:... 3 1.2 Serial Port Pins:... 5 1.3 Applications:... 5 1.4 Your package includes:...
More informationCPC2400E. Embedded Modem Module INTEGRATED CIRCUITS DIVISION. Applications. Approvals UL/C-UL: FCC Reg. # LVRPHL MD-E
Embedded Modem Module Features Easy Integration Small Footprint 1.00" x 2.50" Full Duplex 2400bps Low Power Consumption V.24 DTE Interface Single +5V Supply Operation Supported Protocols: V.22bis, V.23,
More informationIP568x 56K V.90 / V.92 Modem Single Chip
Features Data mode capabilities: ITU-T V.90 ITU-T V.92 (Upgradeable) ITU-T V.34 ITU-T V.32bis, V.32 ITU-T V.22bis,V.22 ITU-T V.23, V.21 Bell 212 Bell 103 FAX mode capabilities: ITU-T V.17, V.29, V.27ter,
More informationG D I. Sunnyvale GENERAL DEVICES & INSTRUMENTS, Inc. MODEL 2400SA. Stand Alone Smart Modem. Revision C
G D I Sunnyvale GENERAL DEVICES & INSTRUMENTS, Inc. MODEL 2400SA Stand Alone Smart Modem Revision C GENERAL The GDI Model 2400SA is a Hayes compatible Dial-up modem, operating at speeds up to 2400 baud.
More informationThe modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface
DESCRIPTION The modems are a series of general-purpose industrial modems, which can be used for data communication through Public Switched Telephone Networks (PSTN). The modems can operate in 2-wire, full-duplex,
More informationTechMemo # B. AlphaEclipse and Alpha signs. See Alpha and AlphaEclipse sign data formats on page 13 for a list of signs.
TechMemo #01-0011B PRIORITY: Normal DATE: August 26, 2004 TITLE: ECO REFERENCE: PRODUCT(S) AFFECTED: SUMMARY: US Robotics 56k modem setup for AlphaEclipse and Alpha signs n/a AlphaEclipse and Alpha signs.
More informationOPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9870E
OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9870E 4-Port, RS232 Serial Module This document describes how to use the National Instruments 9870E and includes dimensions, pin assignments, and specifications
More informationMIU56 Industrial Modem
MIU56 Industrial Modem Designed for unattended sites Designed to survive harsh environmental conditions for unattended operation, such as remote monitoring. Dual Watchdog Timers which can restart the modem
More informationUser's Guide MD 14.4 Industrial Grade Dial Modems Book 1 of 2
User's Guide MD 14.4 Industrial Grade Dial Modems Book 1 of 2 (See Book 2 for AT Commands) Document No. 49-0002-001 Rev.A TABLE of CONTENTS 1. STANDARDS...Page 2 2. PRODUCT OVERVIEW...Page 3 3. GENERAL
More informationIC+ 56k External Data Fax Voice Modem IP568x User s Guide
IC + 56k External Data Fax Voice Modem IP568x FCC Requirements This equipment complies with Part 68 of the FCC Rules. On the bottom of this equipment is a label that contains, among other information,
More information:+,7(3$3(5 MODEM COMMANDS ARMADA 7000 FAMILY PERSONAL COMPUTERS CONTENTS ... October 1997 Prepared By Portables Division Compaq Computer Corporation
:+,7(3$3(5 October 1997 Prepared By Portables Division Compaq Computer Corporation CONTENTS chapter 1 Using Modem Commands 3 chapter 2 Basics of Cellular Phone Use 7 chapter 3 Basics of Digital Simultaneous
More informationIP568x 56K V.90 Modem Single Chip
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 128 39 127 40 126 41 125 42 124 43 123 44 122 45 121 46 120 119 118 47 48 49 117 50 116 51 115 52
More informationCanal+ Compatibility
Canal+ Compatibility Application Note The is a V.22bis (and lower speed) single chip data modem intended to be integrated in any device that requires transferring data over the PSTN (Public Switched Telephone
More informationRev. A FEBRUARY MD1276A Global 56K/V90 Modem User s Guide
0049-2200-001 Rev. A FEBRUARY 2004 0049-2200-500 MD1276A Global 56K/V90 Modem User s Guide Contents Introduction... 6 Installation... 7 Unpacking Your Hardware... 7 Additional Items You Need... 7 Hardware
More informationCellular modem and Transceiver
ARC CDL-900 Cellular modem and Transceiver ARC Electronics 1800-926 926-0226 / 281-392 392-6333 814 Wild Horse Vly Rd Suite "H" Katy, TX 77450 May 11, 1999 Cellular Data Link CDL 900 Point-to-Point Wireless
More informationDIN Rail Mounted Dial-up Modem Users Manual
DIN Rail Mounted Dial-up Modem Users Manual 366-100 Copyright 2002 Miille Applied Research Co., Inc. Houston, Texas Page 1 This page is left blank intentionally Page 2 Page 1 TABLE OF CONTENTS 1.1 General...
More information2001 ESS Technology, Inc. ALL RIGHTS RESERVED.
Copyright Notice Disclaimer Trademarks 2001 ESS Technology, Inc. ALL RIGHTS RESERVED. ESS Technology, Inc. makes no representation or warranties regarding the content of this document. The information
More informationOPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9871E
OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9871E 4-Port, RS485/RS422 Serial Module This document describes how to use the National Instruments 9871E and includes dimensions, pin assignments, and specifications
More informationUSER MANUAL. G.shdsl+ modem with G.703 interface TAHOE 671 FREEDOM OF COMMUNICATION
USER MANUAL G.shdsl+ modem with G.703 interface TAHOE 671 FREEDOM OF COMMUNICATION TABLE OF CONTENTS 1. Introduction... 1 2. Interfaces... 2 3. Modem configuration using built-in keyboard and LCD.4 4.
More informationTote-A-Fax TOTE-A-FAX DATA SPEED FAX SPEED CARRIER DETECT LOW BATTERY. August 1992 FX112A CUSTOMER SUPPORT INFORMATION
August 1992 FX112A Tote-A-Fax DATA SPEED FAX SPEED CARRIER DETECT LOW BATTERY TOTE-A-FAX CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX
More informationUser's Guide MD 14.4L Industrial Grade Dial Modems Book 1 of 2
User's Guide MD 14.4L Industrial Grade Dial Modems Book 1 of 2 (See Book 2 for AT Commands) Document No. 49-0002-001 Rev.A TABLE of CONTENTS 1. STANDARDS...Page 2 2. PRODUCT OVERVIEW...Page 3 3. GENERAL
More informationFAX/DATA MODEM OMNI 56K PCI USER'S MANUAL
FAX/DATA MODEM OMNI 56K PCI USER'S MANUAL i - FCC/DOC REQUIREMENTS i.1 FCC General Information i.2 FCC Notice i.3 DOC Notice 1 - COMMAND REFERENCE 1.1 General Command Information 1.2 AT Commands 1.2.a
More information#!!#!$! # #!!$!% #$!&#&! ##!$ #!!! $! # &! $!!!&%' #!#### # $(! !$ %!$'&!!(!%(!$##! #! %!$&! $!!#)!!'!!&#!!!$!!!!!!$!$!!! (!#!!! $# '!! #!
!" #!!#!$! # #!!$!% #$!&#&! ##!$ #!!! $! # &! $!!!&%' #!#### # $(!!$ %!$'&!!(!%(!$##! #! %!$&! $!!#)!!'!!&#!! $$$#!$!!!!!!$!$!!! (!#!!! $# '!! #! # (# (!!$! #!$!" (!!$!$! ' %!$%!! # (#! #! '!! #!! (!!#
More informationOPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR
1 OPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR Micro Seven, Inc. 1095-K N.E. 25 th Hillsboro, OR 97124 U.S.A. phone: 503-693-6982 fax: 503-693-9742, email to: sales@microseveninc.com www.microseveninc.com
More informationTS-Modem User s Manual
6, Inc. 16525 East Laser Drive Fountain Hills, AZ 85268 480-837-5200 FA 837-5300 info@embeddedx86.com http://www.embeddedx86.com/ This revision of the manual is dated June 5, 2009 All modifications from
More informationi-modul Modem 144/56k 3.0 basic Designer's Guide
i-modul Modem 144/56k 3.0 basic Designer's Guide Copyright July 12 INSYS MICROELECTRONICS GmbH Any duplication of this manual is prohibited. All rights on this documentation and the devices are with INSYS
More informationSocketModem. AT Commands Fax Commands Voice Commands. Reference Guide. SocketModem MT5600SMI SocketModem MT5656SMI
SocketModem SocketModem MT5600SMI SocketModem MT5656SMI AT Commands Fax Commands Voice Commands Reference Guide Copyright and Technical Support SocketModem Reference Guide MT5600SMI and MT5656SMI S000306C,
More informationOPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module
OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module This document describes how to use the National Instruments 9208E and includes dimensions, pin assignments,
More informationApplication Note: AN-146. Guidelines for Effective LITELINK Designs. AN-146-R03 1
Guidelines for Effective LITELINK Designs AN-146-R03 www.ixysic.com 1 1. Introduction Two of the important functions provided by LITELINK to the host systems are high-voltage isolation between the host
More informationISDN Module USER MANUAL
ISDN Module USER MANUAL Program version 1.06 isdn_en 08/08 IMPORTANT The equipment requires an external 12 V DC power supply unit with 500mA current capacity. Making any construction changes or unauthorized
More informationWinmodem PC Card. User s Manual
Winmodem PC Card User s Manual 3Com and the 3Com logo, U.S. Robotics and the U.S. Robotics logo are 3Com Corp. registered trademarks. IBM, IBM PC, PC/XT and PC/AT are International Business Machines Corporation
More informationEA-R03 Wireless Keypad Controller Kit Operating Instructions
Package Contents Normal Use EA-R02-202 Receiver EA-R03-103 Wireless Keypad Transmitter Keypad Mounting Packet Power/Auxiliary Connector Wire Harness Lock/Unlock Relay Connector Wire Harness User Instructions
More informationTRYMUS. 1. Overview. V.22bis/V.32bis/V.34/V.90/V.92 Modem Module with ISOmodem TM. and Global DAA. TRYMUS Corporation. Feature.
1. Overview Feature Data Modem Formats - ITU-T a. UM2404SM : 300bps to 2400bps b. UM2415SM : 300 bps to 14.4kbps c. UM2434SM : 300 bps to 33.6kbps d. UM2457SM : 300 bps to 56kbps e. UM2493SM : 300bps to
More informationSINAUT ST7 Analog Telephone Modem MD3
SINAUT ST7 Analog Telephone Modem MD3 Operating Instructions Edition 07/2002 SINAUT Telecontrol with SIMATIC S7 Overview 1 Mounting and Installation 2 SINAUT ST7 Analog Telephone Modem MD3 (Hardware Version
More informationAREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727.
AREA CODE CHANGE Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727. For any Paradyne telephone number that appears in this manual with an 813 area code,
More informationGeneral Operating, Maintenance and Installation Manual
General Operating, Maintenance and Installation Manual Hardware Platform for Protocol Converter Small Embedded Controller - SEC2-91056 Erlangen Telephone +49 9131 92076-0 Fax: +49 9131 92076-10 Internet:
More informationPreliminary. PACKAGE - 28-pin MLP (5mm X 5mm) Example Circuit Diagram CP V. 48MHz Oscillator. USB Function Controller 512B EEPROM
Preliminary Single-Chip USB to UART Bridge SINGLE-CHIP USB to UART DATA TRANSFER - Integrated USB Transceiver; No External Resistors Required - Integrated Clock; No External Crystal Required - Integrated
More informationDesigner's Guide. Socket Modem 336/56k basic 2.0
Designer's Guide Socket Modem 336/56k basic 2.0 Copyright July 12 INSYS MICROELECTRONICS GmbH Any duplication of this manual is prohibited. All rights on this documentation and the devices are with INSYS
More informationCommunicator ISDN 128 External
Communicator ISDN 128 External User s Manual Version 1.0 Copyright Statement No part of this manual may be reproduced or transmitted, in any form or by any means, electronic or mechanical, including photocopying,
More informationD56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7
D56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7 SECTION 4 - FRONT PANEL INDICATORS...8 SECTION 5 - INTERFACE SIGNALS...9 SECTION 6 -
More informationDPX-213 LOW POWER DATA MODEM USER MANUAL. 2400/1200/300bps MNP-5 Data Leased Line & Dial Network Modem
DPX-213 LOW POWER DATA MODEM USER MANUAL 2400/1200/300bps MNP-5 Data Leased Line & Dial Network Modem WARNING When operating the DPX213 from a DC supply ensure that any devices that are connected to the
More informationObsolete Product(s) - Obsolete Product(s)
8 line low capacitance EMI filter and ESD protection Main product characteristics Where EMI filtering in ESD sensitive equipment is required: LCD and camera for mobile phones Computers and printers Communication
More informationUser Module. AT Modem Emulator APPLICATION NOTE
User Module AT Modem Emulator APPLICATION NOTE USED SYMBOLS Used symbols Danger important notice, which may have an influence on the user s safety or the function of the device. Attention notice on possible
More informationProgramming and Using the Motorola V.3400 Modem for Remote Operation of the DDF6000
Programming and Using the Motorola V.3400 Modem for Remote Operation of the DDF6000 1.0 Introduction A Technical Application Note from Doppler Systems April 11, 1999 Version 3.x of the DDF6000, running
More informationNI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices
INSTALLATION GUIDE NI CB-7F-LP Connector Block for 7-Pin D-Sub Devices Introduction This installation guide describes how to install and connect signals to the NI CB-7F-LP connector block for use with
More informationedbox-100 SmartStack Box for PSTN
Red indication when connected SmartStack Box for PSTN User s Guide DOC0328101E_REV01_09.07.03 TABLE OF CONTENTS 1 GENERAL INFORMATION... 3 1.1 INTRODUCTION... 3 1.2 TECHNICAL FEATURES... 3 1.3 PACKAGE
More informationIML 560 USER GUIDE. Low Power 56Kbps Industrial modem. Version 1.2. December 6, AYANTRA Inc.
IML 560 USER GUIDE Low Power 56Kbps Industrial modem Version 1.2 December 6, 2002 AYANTRA Inc. Revision History Date Version Description By November 18, 2002 1.1 Initial Release - December 6, 2002 1.2
More informationAT Command Set and Register Summary for Cisco PVDM2 Digital Modems
AT Command Set and Register Summary for Cisco PVDM2 Digital Modems First Published: August 15, 2007 Last Updated: December 5, 2007 This document describes modem AT commands and S-registers for Cisco PVDM2-xxDM
More informationEXM K Baud V.32bis Modem Hardware Reference
EXM-31 14.4K Baud V.32bis Modem Hardware Reference RadiSys Corporation 15025 S.W. Koll Parkway Beaverton OR 97006 (503) 646-1800 FAX: (503) 646-1850 07-0255-00 May 1995 AT&T is a registered trademark of
More informationHSF FAX / MODEM USER'S GUIDE. SoftSoft. Ver 1.0
SoftSoft HSF FAX / MODEM USER'S GUIDE Ver 1.0 CTR-21 Compliance Statement The equipment has been approved in accordance with Council Decision 98/482/EC for pan- European single terminal connection to the
More informationProduct: Z34-SX, Z34-RX, Z34-SE, Z34-RE, Z32t-SX, Z32t-SE, Z32t-RX, Z32b-SX, Z32b-SE, Z32b-RX
Product: Z34-SX, Z34-RX, Z34-SE, Z34-RE, Z32t-SX, Z32t-SE, Z32t-RX, Z32b-SX, Z32b-SE, Z32b-RX Application: Leased Line Operation with Dial Backup/Auto-Restoral Basic leased line operation can be set using
More informationISDN OEM1. DesignGuide V1.2
ISDN OEM1 DesignGuide V1.2 Content ISDN OEM1...1 1 Objective...3 2 Product description...3 3 Software interfaces...4 3.1 Dialing procedures...4 3.2 AT commands...4 3.2.1 Configuration commands...4 3.2.2
More informationSMP75. Trisil for telecom equipment protection. Features. Description. Applications. Benefits
Trisil for telecom equipment protection Features bidirectional crowbar protection voltage: 8 V low leakage current: I R = 2 µa max holding current: I H = 15 ma min repetitive peak pulse current: I PP =
More informationSERVICE MANUAL MODEL SSP-363-E (FORMERLY SSP-365-E)
SSP-363-E-(SSP-365-E)-ADT1.03-ISSUE4.0 SERVICE MANUAL FOR MODEL SSP-363-E (FORMERLY SSP-365-E) STAINLESS STEEL PANEL TELEPHONE WITH 12 BUTTON AUTOMATIC DIALER EQUIPPED WITH ADT1.03 FIRMWARE Serving the
More informationNI 6521 Specifications
NI 6521 Specifications This document lists specifications for the NI 6521 device. All specifications are subject to change without notice. These specifications are typical at 25 C unless otherwise noted.
More informationSuperBus 2000 Phone Interface/Voice Module Installation Instructions
SuperBus 2000 Module Installation Instructions Product summary The SuperBus 2000 (PIV) Module provides phone and voice functions for the Concord, Concord 4, and Concord Express (v4) panels. The PIV module
More informationEMIF M8. 4-line IPAD low capacitance EMI filter and ESD protection in micro QFN package. Features. Applications. Description
4-line IPAD low capacitance EMI filter and ESD protection in micro QFN package Features EMI symmetrical (I/O) low-pass filter High efficiency in EMI filtering: -34 db at frequencies from 900 MHz to 1.8
More informationEVAL6235PD. L6235 three-phase brushless DC motor driver demonstration board. Features. Description
L6235 three-phase brushless DC motor driver demonstration board Features Operating supply voltage from 8 V to 52 V 5.6 A output peak current (2.8 A RMS ) Operating frequency up to 100 khz Non-dissipative
More informationAN2470 Application note TS4871 low voltage audio power amplifier Evaluation board user guidelines Features Description
Application note TS4871 low voltage audio power amplifier Evaluation board user guidelines Features TS4871 low voltage audio power amplifier with active low standby mode Operating range from V CC =2.2V
More informationAN2408 Application note
Application note 900mA standalone linear Li-Ion battery charger with thermal regulation Introduction One way to minimize the size and complexity of a battery charger is to use a linear-type charger. The
More informationwireless N 4-port router quick
wireless N ADSl2+ 4-port router quick install guide Models 524360 (annex A) & 524377 (annex b) INT-524360/524377-QIG-1208-01 Thank you for purchasing the INTELLINET NETWORK SOLUTIONS Wireless N ADSL2+
More informationUniversal communications device Metcom T A..
Universal communications device Metcom T A.. Manual Order-No. E 858-102 1 2 3 4 5 6 7 8 1 RUN-LED for power on 2 RI-LED: Ring Indication 3 DCD-LED: Data Carrier Detect 4 RxD-LED: Receive Data 5 TxD-LED:
More informationHYDROTHUNDER PARTS C H A P T E R F O U R
HYDROTHUNDER C H A P T E R F O U R PARTS WARNING: USE OF NON-MIDWAY PARTS OR CIRCUIT MODIFICATIONS MAY CAUSE SERIOUS INJURY OR EQUIPMENT DAMAGE! USE ONLY MIDWAY AUTHORIZED PARTS. For safety and reliability,
More informationSERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELEPHONE WITH OPTIONAL ADA FEATURE
WPP-531-D OR SSP-511-D-SPK1.07UNVLr1-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELEPHONE WITH OPTIONAL ADA FEATURE OR MODEL SSP-511-D STAINLESS STEEL PANEL TELEPHONE WITH OPTIONAL ADA
More informationPAA191STR. Dual Single-Pole, Normally Open OptoMOS Relays INTEGRATED CIRCUITS DIVISION
Dual Single-Pole, Normally Open OptoMOS Relays Parameter Rating Units Load Voltage 4 V P Load Current ma rms / ma DC On-Resistance (max 8 Features V rms Input/Output Isolation Low Drive Power Requirements
More informationLCA127STR. Single-Pole, Normally Open OptoMOS Relay INTEGRATED CIRCUITS DIVISION
Single-Pole, Normally Open OptoMOS Relay Parameter Ratings Units Blocking Voltage V P Load Current ma rms / ma DC On-Resistance (max Features 37V rms Input/Output Isolation Low Drive Power Requirements
More informationEMIF02-MIC01F2 2-line IPAD, EMI filter including ESD protection Features Application Description Complies with the standards:
2-line IPAD, EMI filter including ESD protection Features 2-line symetrical low-pass filter Lead-free package High-density capacitor High-efficiency EMI filtering Very small PCB footprint: 1.42 mm x 1.92
More informationEMIF01-SMIC01F2 IPAD. Single line EMI filter including ESD protection. Main application. Description. Benefits. Pin configuration (Bump side view)
IPAD Single line EMI filter including ESD protection Main application Single ended microphone in mobile phones and portable devices Description The is a highly integrated device designed to suppress EMI/RFI
More informationHost-Based Controller Modem AT Command Set
Data Addendum June 15, 1998 Version 1.1 Host-Based Controller Modem AT Command Set Contents Page Introduction AT Command Summary...2 AT Commands Reference...6 Test and Debug AT Commands...24 AT Commands
More informationAtrie 288LCD MODEM User's Manual
Atrie 288LCD MODEM User's Manual 288LCD MODEM USER'S MANUAL ATRIE TECHNOLOGY INC. ATRIE 336/288/144LCD MODEM USER'S MANUAL (Version 4) Atrie Technology Inc. 10th Floor, No.14, Lane 609, Sec. 5, Chung Hsin
More informationE&M (Ear and Mouth) Interface For OM200 SONET-OC3 Multiplexer
-& & (ar and outh) Interface For SONT-OC3 ultiplexer Chassis Chassis sizes of 2, 4, 6, and 16 slot. Optical data rate of 155bps Single or multimode fiber versions Point-to-point topology Add/drop topology
More informationEMIF M16. 8-line IPAD low capacitance EMI filter and ESD protection in micro QFN package. Features. Description.
8-line IPAD low capacitance EMI filter and ESD protection in micro QFN package Features EMI (I/O) low-pass filter High efficiency in EMI filtering: Greater than 30 db attenuation at frequencies from 900
More informationCerberus Division. Installation Instructions CERBERUS PYROTRONICS TM Model RDM-MXL. (Remote Diagnostics Module)
Cerberus Division Installation Instructions CERBERUS PYROTRONICS TM Model RDM-MXL Remote Diagnostics Module INTRODUCTION The CERBERUS PYROTRONICS TM Model RDM-MXL module (RDM for connection to the MXL
More informationAgilent 66000A 1200 W DC Modular Power System, GPIB
Agilent 66000A 1200 W DC Modular Power System, GPIB Data Sheet Speed and accuracy for test optimization 8-slot mainframe accepts up to 8 DC power modules 1200 W total DC power output, up to 150 W per module
More informationNI SMB-2145/2146/2147/2148
USER GUIDE NI SMB-2145/2146/2147/2148 Shielded Signal Accessories for NI 5751/5752 Adapter Modules The NI SMB-2145/2146/2147/2148 (NI SMB-214x) devices are shielded signal accessories for NI FlexRIO digitizer
More informationAB300-Series Automated Filter Wheels
AB300-Series Automated Filter Wheels User Manual 1049478 August 2006 1. Introduction 1.1 Mission Statement Our mission is to provide our customers with reliable products, on time, and at a fair price.
More informationSpectraGuard Sensor SS-300-AT-C-50 Technical Specifications
SpectraGuard Sensor SS-300-AT-C-50 Technical Specifications 1 Product Overview ITEM Product Name Model Number Power Supply SpectraGuard Sensor SS-300-AT-C-50 802.3af Class 0 Power Over Ethernet Nominal
More informationEasy Installation Guide
Easy Installation Guide Remote Engineer Router ServiceGate Remote Engineer B.V. De Parse 11, 8491 PJ, Akkrum The Netherlands +31 527 712 049 info@remoteengineer.eu www.remoteengineer.eu Package Contents
More information