1 Site Ethernet Interface Installation Manual PK XXXX 10/03 1 of 22
2 Second Edition A publication of Kaba Ilco, Inc Decarie Blvd. Montreal, Quebec Canada H4P 2G7 Printed in Canada, 2002 Copyright by Kaba Ilco, Inc., 2002 All rights reserved. No part of this booklet may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or by any information storage and retrieval system, without prior written permission from the Publisher. The information contained in this publication is accurate to the best of Kaba Ilco s knowledge. Specifications are subject to change without notice. PK XXXX 10/03 2 of 22 PK XXXX 10/03
3 Contents What is an SEI?...5 When do I use SEIs?...5 What are the network requirements?...8 What are the minimum Millenium software requirements?...8 What are the minimum Millenium PC requirements?...9 What are the wiring requirements?...9 What are the serial wiring pinouts?...9 What are the cabling distance limitations?...9 Where do I connect the SEI to the SCU?...10 How do I program the SEI?...11 Preparations...11 HyperTerminal...12 How do I program the SEI in Millenium?...18 What are the general specifications of an SEI?...20 SEI programming quick sheet PK XXXX 10/03
4
5 What is an SEI? The SEI (Site Ethernet Interface) connects a SCU (Site Control Unit) to an Ethernet network using TCP/IP (Transmission Control Protocol/Internet Protocol). In other words, the SEI lets you communicate through a network to a remote SCU. When do I use SEIs? You would usually use SEIs when you want to connect to SCU s that are remotely located away from the PC/Server. The main Millenium PC can be either a standalone PC or the Millenium Server if you are using the Millenium Server/Workstation configuration. Figure 1.Installation diagram showing the Millenium standard configuration. Ethernet Millenium Stand Alone PC SEI SCU Notice that you are connecting the SCU to an SEI instead of to the PC as you would normally do. Here, the SCU is communicating to the PC via the SEI. The SEI/SCU combo can be used ANYWHERE on a network and multiple SEI/SCU combos can be used on the same network. PK XXXX 10/03 5 of 22
6 Figure 2. Installation diagram showing the Millenium standard configuration and mixed communications. SCU #1 SEI SCU # 2 Ethernet Millenium Stand Alone PC SEI SCU #3 Notice that you are making 2 types of connections: SCU #1 to the Millenium PC SCUs #2 and #3 to SEIs. This is possible because Millenium communication modes. permits simultaneous use of different In this example, SCU #1 is connected to the Millenium PC and can communicate with one site while the SEI/SCU combos could be communicating with different sites or locations. 6 of 22 PK XXXX 10/03
7 Figure 3.Installation diagram showing the Millenium Server/Workstation configuration. Millenium Workstation Ethernet Millenium Server PC SEI SCU Millenium Workstation The SCU is communicating to the Millenium Server PC using the SEI and the Millenium Server PC is communicating with the workstations. The SEI/SCU combo can be used ANYWHERE on the network and multiple SEI/SCU combos can be used on the same network. PK XXXX 10/03 7 of 22
8 Figure 4.Installation diagram showing the Millenium configuration and mixed communication modes. Server/Workstation SCU #1 Modem SCU #2 Millenium Server PC Millenium Workstation SEI Ethernet SEI SCU #4 SCU #3 Millenium Workstation SCU #1 is communicating with the Millenium Server PC using a modem, SCU #2 is communicating with the Millenium Server PC using a null modem serial cable and SCUs #3 and #4 are communicating with the Millenium Server PC using SEIs. The Millenium Server PC is communicating with the Millenium Workstations. The SEI/SCU combo can be used ANYWHERE on the network and multiple SEI/SCU combos can be used on the same network. Notes: In all examples, SEIs and SCUs work as a pair. Buy at least 1 SCU for every 1 SEI installed. In some mixed communications installations, there can be more SCUs then SEIs but you can never have more SEIs. What are the network requirements? TCP/IP 10baseT (The SEI will not communicate on 100baseT) Static IP addresses What are the minimum Millenium software requirements? Millenium software version or higher. Millenium comes SEI ready with no additional software components needed. 8 of 22 PK XXXX 10/03
9 What are the minimum Millenium PC requirements? Networked PC Pentium class PC. 128 MB of RAM or higher. 10 GB Hard drive minimum. 1 CD-ROM drive 8X or higher. 1 Floppy drive. 1 Serial port (2 recommended). Windows 98 Se and above (Windows 2000 Sp3 recommended). 1 Ethernet card. What are the wiring requirements? From the SEI to the SCU : Standard Modem cable (DB-25 male/ DB- 9 female) From the Network connector to the SEI : RJ-45 cable Figure 5. RJ-45 network cable. What are the serial wiring pinouts? DB-25 to DB-9 2 to 3 3 to 2 4 to 7 5 to 8 6 to 6 7 to 5 8 to 1 20 to 4 22 to 9 The DB-25 connects to CH1 of the SEI The DB-9 connects to J3 of the SCU What are the cabling distance limitations? From the Network connector to the SEI: 300 ft (using CAT5 cabling.) From the SEI to the SCU: 50 ft. PK XXXX 10/03 9 of 22
10 Where do I connect the SEI to the SCU? Connect the SEI Channel 1 port (CH1) to the DB-9 port on the SCU (J3 port connector). Figure 6. SCU J3 port connector on the SCU. This is where you connect the SEI. Using a standard modem cable (DB-25 male/db-9 female), you connect the channel 1 port from the SEI to the J3 port on the SCU. Figure 7. SEI Note: Only the Channel 1 port connector is used with Millenium. 10 of 22 PK XXXX 10/03
11 How do I set up the SCU when using an SEI? Set the function switches (S5 switches) on the SCU for: Wired and RS-232. How do I program the SEI? The SEI needs to be programmed with vital information before connecting it to the SCU. HyperTerminal (a basic program that comes with Windows) is used for the programming procedure. Preparations A. Hardware and Software requirements. 1 PC with at least one serial port. This PC will be used to program the SEI. 1 Standard modem cable (DB-25 male/db-9 female). HyperTerminal program. PK XXXX 10/03 11 of 22
12 B. Information Requirements (from your customer s IT department). Serial port number you will be using to program the SEI with HyperTerminal (Usually, COM 1). IP address of the SEI. IP address of the Millenium PC (or the Millenium Server PC if using the Server/Workstation configuration).. The Gateway IP addresses (if any). The network class (A, B, or C) if your customer is using a subnet mask. Ask your customer s IT department the type of netmask they use: > Class A network > Class B network > Class C network. HyperTerminal Connect channel 1 of the SEI to the serial port of the PC using a standard modem cable (DB-25 male/db-9 female). TO PC Plug the AC adapter into a regular electrical outlet but DO NOT plug the other end into the SEI. Launch HyperTerminal. You will usually find this program by navigating from the start menu to: Programs -> Accessories -> HyperTerminal. 12 of 22 PK XXXX 10/03
13 Screen Shots PK XXXX 10/03 13 of 22
14 When launching HyperTerminal, the connection description dialog box will pop up. In the Name box, type SEI SETUP (or any other name you choose). Click on OK. The connect to dialog box will appear. Choose the Serial port number where you connected the SEI to the PC. Click on OK. A properties box will pop up, you MUST configure your port as shown below: 14 of 22 PK XXXX 10/03
15 Bits per Second: 9600 Data bits: 8 Parity: None Stop bits: 1 Flow control: None or Hardware Click OK. Hold down the x key on the computer keyboard while connecting power to the SEI. Keep holding the x key until you see: *** Lantronix Cobox Universal Thin Server *** To the AC adapter Serial Number Software Version V 4.5 Press Enter to go into Setup Mode PK XXXX 10/03 15 of 22
16 Please note the serial number will be different but the software version may be different or the same. Press Enter. The screen shown below appears: ***************** Channel 1 ***************** Baudrate 09600, I/F Mode 4C, Flow 00 Port Remote IP Adr: --- none ---, Port Connect Mode: D0 Disconn Mode: 00 Flush Mode: 00 Change Setup : 0 Server configuration 1 Channel 1 configuration 5 Expert Settings 6 Security 7 factory defaults 8 exit without save 9 save and exit Your choice? Press 0 IP Address: You will see Set Gateway IP Address (N) Netmask: Number of Bits for Host Part (0=default) Change telnet config password (N) SEI IP address You must type N if not used or the IP address if used 08 if Class C network (Netmask ) 24 If Class A network (Netmask ) 16 If Class B network (Netmask ) 00 if left at Default (Netmask ) N 16 of 22 PK XXXX 10/03
17 Once finished, you will see: Change Setup : 0 Server configuration 1 Channel 1 configuration 5 Expert Settings 6 Security 7 factory defaults 8 exit without save 9 save and exit Your choice? Type 1 You will see Baudrate (09600)? I/F Mode (4C)? Flow (00)? Port No (00000)? ConnectMode (C0)? Remote IP Address : Remote Port (00000)? DisConnMode (00)? FlushMode (00)? Pack Cntrl (00)? DisConnTime ( 00:00)?: SendChar 1 (00)? SendChar 2 (00)? You must type C D0 Millenium PC IP address or Millenium Server IP Address (if using the Server / Workstation configuration) : PK XXXX 10/03 17 of 22
18 Once the configuration finished, you will see: Change Setup : 0 Server configuration 1 Channel 1 configuration 5 Expert Settings 6 Security 7 factory defaults 8 exit without save 9 save and exit Your choice? Press 9 The SEI is now programmed How do I program the SEI in Millenium? Launch Millenium Setup Logon Click on Ports from the menu bar Choose SEI IP Addresses 18 of 22 PK XXXX 10/03
19 Type the SEI IP address and give it a name. Press the Assign arrow to save your changes Close Millenium setup Launch Millenium Log on Click on sites Program the SCU the usual way. Refer to the online help. Click on Communication PK XXXX 10/03 19 of 22
20 Choose the SEI name you previously programmed to link the SEI to the SCU Click OK Click Save The SEI and the SCU are programmed in Millenium. What are the general specifications of an SEI? PORTS Network: Ethernet: RJ45 (10BASE-T) and AUI Token Ring: STP (SubD9) and UTP (RJ45) Serial: (only one port can be used) DB25 RS232/RS422/RS485 serial port (DCE configuration) DB9 RS232 serial port (DTE configuration) DATA RATES 300bps to 115Kbps SERIAL LINE FORMATS MODEM CONTROLS FLOW CONTROL Characters: 7 or 8 data bits Stop bits: 1 or 2 Parity: odd, even, none RTS, CTS, DSR, DCD, DTR XON/XOFF; RTS/CTS 20 of 22 PK XXXX 10/03
21 MANAGEMENT Internal HTTP server SNMP (read only) Serial login Telnet login SYSTEM FIRMWARE Flash ROM standard: new software can be downloaded via Tftp or over serial port DIAGNOSTIC LEDS Good Link (green) Network transmit/receive data (yellow) Collisions (red) Diagnostic (red) Status (green) POWER REQUIREMENTS External adapter included as 110 VAC (-01 models) or 230 VAC (-02 models) Required input power of 250mA max. ENVIRONMENTAL Operating Temperature: 5 to 50C (41 to 122F) Storage Temperature: -40 to 66C (-40 to 151F) AGENCY LISTINGS PHYSICAL DIMENSIONS SHIPPING DIMENSIONS CE, FCC A, TUV, C/UL 0.9 x 2.5 x 3.5 in (2.3 x 6.4 x 9.0 cm) Weight: 0.8 lbs (.35kg) 4.5 x 9.5 x 7.5 in (11.5 x 24.2 x 19.1 cm) Weight: 3.0 lbs (1.5kg) PK XXXX 10/03 21 of 22
22 SEI programming quick sheet. BOLD characters must be entered exactly as shown. BOLD italic characters are Kaba Ilco suggested defaults. Characters in [Brackets] are entered only if applicable to your network. ***Basic parameters (Option 0 from the setup Menu). Ethernet Interface AUI (N) IP Address Set Gateway IP Address Gateway IP Address N SEI IP ADDRESS N [Gateway IP ADDRESS] (if any). Netmask: Number of Bits for Host Part [00] If you have a Class A Network [24] If you have a Class B Network [16] If you have a Class C Network [08] Change telnet config password N *** Channel 1 (Option 1 from the setup Menu). Baud rate 9600 I/F Mode 4C Flow 00 Port No Connect Mode Remote IP Address When not using the Millenium Network package When using the Millenium Network package D0 Millenium PC IP Address Millenium Server IP Address Remote Port DisConnMode 00 Flush Mode 84 Pack Cntrl 00 DisConnTime 10:00 SendChar 1 03 SendChar of 22 PK XXXX 10/03
Conettix ITS-D6682-INTL
Conettix ITS-D6682-INTL EN Installation Guide Ethernet Network Adapter Conettix ITS-D6682-INTL Installation Guide Contents Contents 1.0 Introduction... 3 1.1 Network Interface... 3 1.2 Serial Interface...
More informationTITLE: Device Server Configuration/Installation Manual
TITLE: Device Server Configuration/Installation Manual TechNote: 000269 Symptom: Error Message: Solution: 1: Device Server Introduction A: Overview B: Redirector Software C: Typical Installation 2: Hardware
More informationConettix ITS-D6682-UL
Conettix ITS-D6682-UL EN Installation Guide Ethernet Network Adapter Conettix ITS-D6682-UL Installation Guide Contents Contents 1.0 Introduction...3 1.1 Network Interface... 3 1.2 Serial Interface... 3
More informationRS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual
RS-232/422/485 to Copper or Fiber Ethernet Converter User s Manual Table Of Contents TABLE OF CONTENTS... 1 INTRODUCTION... 3 PRODUCT OVERVIEW... 3 PRODUCT FEATURES... 3 PACKING LIST... 4 LED INDICATORS...
More informationConettix ITS-D6686-INTL
Conettix ITS-D6686-INTL EN Installation Guide Ethernet Network Adapter Conettix ITS-D6686-INTL Installation Guide Contents Contents 1.0 Introduction... 3 1.1 Network Interface... 3 1.2 Serial Interface...
More informationConettix D6680. Installation Instructions. Ethernet Network Adapter
Conettix D6680 EN Installation Instructions Ethernet Network Adapter Conettix D6680 Installation Instructions Trademarks Trademarks Microsoft Windows 98SE, Windows ME, Windows 2000, Windows NT, MS-DOS,
More informationSCS1600/3200 Quick Start Guide
Secure Console Servers Quick Start Guide 2003 Copyright Lantronix is a trademark of Lantronix. All rights reserved. 900-233 Rev. D 11/03 QUICK START CONTENTS System Overview.......................................................2
More informationGE-DSH-73/82 and 82-POE Managed Switch Installation Sheet
GE Security GE-DSH-73/82 and 82-POE Managed Switch Installation Sheet Package Contents Thank you for purchasing the GE Security 7/8-Port Fast Ethernet + 2/3-Port Gigabit TP/SFP Combo Managed Switch. The
More informationNCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL
NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT
More informationConettix ITS-D6686-UL PRELIMINARY. Installation Guide. Ethernet Network Adapter
Conettix ITS-D6686-UL EN Installation Guide Ethernet Network Adapter Conettix ITS-D6686-UL Installation Guide Contents Contents 1.0 Introduction... 3 1.1 Network Interface... 3 1.2 Serial Interface...
More informationConettix ITS-D6686-UL
Conettix ITS-D6686-UL EN Installation Guide Ethernet Network Adapter Conettix ITS-D6686-UL Installation Guide Contents Contents 1.0 Introduction... 3 1.1 Network Interface... 3 1.2 Serial Interface...
More informationDocument Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index
Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index Technical Specifications 1 Installation Procedure 1 LED Indications 2 Configuration Procedure Configuration
More informationXPress DR+W Quick Start Guide
Industrial Device Server Quick Start Guide 2006 Copyright Lantronix is a trademark of Lantronix. All rights reserved. 900-446 Rev. A 10/06 XPRESS DR+W QUICK START CONTENTS What s In the Box..........................................................2
More information28-Port 10/100/1000Mbps with. 4 Shared SFP Managed Gigabit Switch WGSW / WGSW-28040P. Quick Installation Guide
28-Port 10/100/1000Mbps with 4 Shared SFP Managed Gigabit Switch WGSW-28040 / WGSW-28040P Quick Installation Guide Table of Contents 1. Package Content... 3 2. Requirements... 4 3. Terminal Setup... 5
More information24-Port Gigabit with 4 Optional 10G Slots. Layer 3 Managed Stackable Switch XGS Quick Installation Guide
24-Port Gigabit with 4 Optional 10G Slots Layer 3 Managed Stackable Switch XGS3-24040 Quick Installation Guide Table of Contents 1. Package Content... 3 2. Switch Management... 4 3. Requirements... 5 4.
More informationIndustrial Serial Device Server
1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device
More informationUSER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)
USER S MANUAL PH232Ex1 Doc No: PH232Ex1-UM-001 #1 RS-232 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...
More informationDGH A3000 Configuration Guide For use with DGH Modules
DGH A3000 Configuration Guide For use with DGH Modules Revision Date: 12/07/05 Version: 1.00 Contact Information: http://www.dghcorp.com Ph: (603) 622-0452 Fax: (603) 622-0487 Mailing Address: DGH Corporation
More informationNCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL
NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT
More informationNetBiter Serial Server User Manual
User Manual IntelliCom Innovation AB Linjegatan 3D SE-302 50 Halmstad SWEDEN Phone +46 35 18 21 70 Fax +46 35 17 29 09 email info@intellicom.se web www.intellicom.se Revision List Revision Date Author
More informationTel: Fax:
NP302 Series 2-port RS-232 232/485/422 to Ethernet Serial Server User manual Shenzhen 3onedata Technology Co.,Ltd Tel: +86-755-26702688 Fax: +86-755-26703485 www.3onedata.com Contents 1. Introduction...
More information24-Port 10/100/1000Mbps with. 4 Shared SFP Managed Gigabit Switch
24-Port 10/100/1000Mbps with 4 Shared SFP Managed Gigabit Switch WGSW-24040 / WGSW-24040R SGSW-24040 / SGSW-24040R SGSW-24040P / SGSW-24040P4 SGSW-24240 / SGSW-24240R SGSW-24040HP Quick Installation Guide
More information24-Port Gigabit with 4 Optional 10G Slots. Layer 3 Managed Stackable Switch XGS / XGS Quick Installation Guide
24-Port Gigabit with 4 Optional 10G Slots Layer 3 Managed Stackable Switch XGS3-24042 / XGS3-24242 Quick Installation Guide Table of Contents 1. Package Content... 3 2. Switch Management... 4 3. Requirements...
More informationWiSpan Quick Start Guide
Quick Start Guide 2008 Copyright Lantronix is a trademark of Lantronix. All rights reserved. 900-462 Rev. B 06/08 QUICK START CONTENTS What s In the Box..........................................................2
More informationRS232/RS485/RS422 to TCP/IP Converter ITEM NO.: RS007
RS232/RS485/RS422 to TCP/IP Converter ITEM NO.: RS007 RS007 is a universal data converter which support serial RS232, RS422 and RS485 to the TCP / IP intelligent communication converter, it offers RS485/RS422
More informationSERIAL TO ETHERNET CONVERTER E-P User Manual
SERIAL TO ETHERNET CONVERTER E-P132-100 User Manual 1 Table of Contents Introduction... 4 Overview.. 5 Package Checklist 6 Block Diagram 7 Product Features...8 Product Specifications 9 Converter Description
More informationAppendix A Cable Pinouts
Appendix A Cable Pinouts This appendix lists the cables and connector pinout assignments for the cables used with the ERX-7xx models and ERX-14xx models. Topic Page SRP I/O Module 163 CT1 and CE1 I/O Modules
More information8-Port 10/100Mbps + 2G TP/SFP Combo. Managed Industrial Switch ISW-1022M / ISW-1022MT / ISW-1022MP / ISW-1022MPT / ISW-1033MT
8-Port 10/100Mbps + 2G TP/SFP Combo Managed Industrial Switch ISW-1022M / ISW-1022MT / ISW-1022MP / ISW-1022MPT / ISW-1033MT Quick Installation Guide Table of Contents 1. Package Content... 3 2. Requirements...
More informationSCS100/200/400 Quick Start Guide
900-320 Rev. A 9/25/03 4:07 PM Page 1 Secure Console Servers 2003 Copyright Lantronix is a registered trademark of Lantronix, Inc. All rights reserved. 900-320 Rev. A 9/03 900-320 Rev. A 9/25/03 4:07 PM
More informationUser Manual A08. User Manual
A08 TABLE OF CONTENTS TABLE OF CONTENTS... 1 1. INTRODUCTION... 2 1.1. Key Features... 3 1.2. OS Requirement... 4 1.3. Specification... 4 1.4. Packing List... 4 2. OVERVIEW... 5 2.1. LED Definition...
More informationNetCom Mini. SCADA system Building automation system Self-service banking system Other remote and distributed serial devices control
Features Can control 1 x RS232 device located virtually anywhere (via Ethernet or Internet) LAN interface 10BaseT/100BaseTx Ethernet Configuration utility automatically finds NetCom Mini devices in the
More informationCable Pinouts. SRP I/O Module
Cable Pinouts A This appendix lists the cables and connector pinout assignments for the cables used with the ERX-7xx models and ERX-14xx models. Topic Page SRP I/O Module A-1 CT1 and CE1 I/O Modules A-4
More informationManagement Security Switch SGSD-1022 / SGSD-1022P SGSW-2840 / SGSW-2840P. Quick Installation Guide
Management Security Switch SGSD-1022 / SGSD-1022P SGSW-2840 / SGSW-2840P Quick Installation Guide Table of Contents 1. Package Content... 3 2. Requirements... 4 3. Terminal Setup... 5 4. Logon to the Console...
More information62532 (EN649) Ethernet Adapter
62532 (EN649) Ethernet Adapter INSTALLATION AND OPERATING INSTRUCTIONS For sales and Service in North America contact: ESD Systems.com www.esdsystems.com sales@esdsystems.com Phone: 508-485-7390 Fax: 508-480-0257
More informationEthernet Serial Server
Ethernet Serial Server Users Manual Eport-101, Eport-102, Eport-104, Eport108 1 INTRODUCTION... 1 1.1 FEATURES... 1 1.2 PRODUCT SPECIFICATIONS... 2 1.3 DEFAULT SETTINGS... 3 2 COMMUNICATION MODES... 4
More informationEtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X
EtherSeries EtherSeries CR-2 & CR-2-Opto User s Guide Revised October 7, 2013 Firmware Version 1.X TABLE OF CONTENTS SECTION 1 - DESCRIPTION... 2 SECTION 2 - SPECIFICATIONS... 4 SECTION 3 - INSTALLATION...
More informationLantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual
Lantech LSC-1102B SERIAL TO TCPIP CONVERTER User Manual V1.0 Sep 2016 Table of Contents 1. Introduction 3 Overview 4 Product Specifications 8 2. Description & Installation 10 Product Panel Views 10 LED
More informationMSS100 / MSS-VIA / MSS4 Quick Start Guide
Device Servers Quick Start Guide 2003 Copyright Lantronix is a registered trademark of Lantronix, Inc. All rights reserved. 900-321 Rev. A 11/03 QUICK START CONTENTS System Overview.......................................................2
More informationInstallation and User Guide
Installation and User Guide Trademarks and Notices Notice Comtrol Corporation. SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS OF THIS PRODUCT FOR A PARTICULAR PURPOSE. Comtrol
More informationWiBox 2100 Quick Start Guide
WIBOX 2100 Quick Start Guide 2004 Copyright Lantronix is a trademark of Lantronix. All rights reserved. 900-367 07/04 WIBOX 2100 QUICK START CONTENTS What s in the Box..........................................................2
More informationNetCom 413 PRO. Contact Online. More Pictures. Klick on the thumbnails for the large picture. Overview
VS Vision Systems GmbH / Part Number 676 Features Controls 4 RS232/422/485 devices located virtually anywhere via Ethernet or Internet Secure encryption on Ethernet LAN interface 10BaseT/100BaseTx Ethernet
More information24-Port Gigabit + 4-Port 10G SFP+ Slot. Layer 3 Stackable Managed Switch XGS Quick Installation Guide
24-Port Gigabit + 4-Port 10G SFP+ Slot Layer 3 Stackable Managed Switch XGS3-24042 Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Switch Management... 4 3. Requirements... 5 4.
More informationUSB Connectivity. USB Connectivity
Connectivity Product Selection Guides -to-serial Server Selection Guide.......................................-2 Hub Selection Guide................................................-4 -to-serial Converters
More information48-Port 10/100Mbps + 4 Gigabit TP / 2 SFP. Managed Switch WGSW Quick Installation Guide
48-Port 10/100Mbps + 4 Gigabit TP / 2 SFP Managed Switch WGSW-5242 Quick Installation Guide Table of Contents 1. Package Content... 3 2. Requirements... 4 3. Terminal Setup... 5 4. Logon to the Console...
More informationDomain 3000 Back Panel
Domain 3000 Back Panel The Domain 3000 has 25 I/O ports plus a connector for an external power supply (included) and an LED to indicate that the power is on. Typically, it is placed on a shelf or equipment
More informationDeviceMaster RTS 16-Port Hardware Installation
DeviceMaster RTS -Port Hardware Installation Red underscored text link to Internet URLs. Blue underscored text link to sections within this document or to another document in the library. Note: If you
More information48-Port 10/100/1000Base-T with 4 Shared SFP. Managed Gigabit Switch WGSW Quick Installation Guide
48-Port 10/100/1000Base-T with 4 Shared SFP Managed Gigabit Switch WGSW-48000 Quick Installation Guide Table of Contents 1. Package Content... 3 2. Requirements... 4 3. Terminal Setup... 5 4. Logon to
More information24-Port 100/1000X SFP + 4-Port 10G SFP+ Managed. Metro Ethernet Switch MGSW-28240F. Quick Installation Guide
24-Port 100/1000X SFP + 4-Port 10G SFP+ Managed Metro Ethernet Switch MGSW-28240F Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4 3. Wiring DC Power Inputs... 5
More informationINDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter
Document Name : User Manual for SC10EJ Serial to Ethernet Converter Page 1 of 10 INDEX 1. Technical Specifications 1 2. Modes of Operation 1 3. Configuring the SC10 EJ : Through Serial Port 2 a. Configuring
More informationGetting Started Guide for the Remote Access Dial-in Ethernet Modem 9300-RADES
Getting Started Guide for the Remote Access Dial-in Ethernet Modem 9300-RADES - Unpacking your 9300-RADES - Setting up 9300-RADES for an Ethernet Connection - Setting up 9300-RADES for a Modem Connection
More informationUDS1100 User Guide Part Number Revision D August 2008
UDS1100 User Guide Part Number 900-417 Revision D August 2008 Copyright & Trademark Contacts 2006, 2007, 2008 Lantronix. All rights reserved. No part of the contents of this book may be transmitted or
More informationEDS4100 Quick Start Guide
Quick Start Guide 2006 Copyright Lantronix is a trademark of Lantronix. All rights reserved. 900-419 Rev. A 03/06 QUICK START GUIDE CONTENTS What s In the Box.......................................................2
More informationEX-6014WI RS232 to WiFi Wireless Adapter, w/ Mounting Kit
EX-6014WI RS232 to WiFi Wireless Adapter, w/ Mounting Kit Thank you for purchasing this RS232 to WiFi Wireless Adapter (hereinafter referred to as WiFi-Adapter ), it is designed to communicate with RS232
More informationedbox-100 SmartStack Box for PSTN
Red indication when connected SmartStack Box for PSTN User s Guide DOC0328101E_REV01_09.07.03 TABLE OF CONTENTS 1 GENERAL INFORMATION... 3 1.1 INTRODUCTION... 3 1.2 TECHNICAL FEATURES... 3 1.3 PACKAGE
More informationInternational Headquarters. European Headquarters
VLINX VESP211 SERIAL SERVER Document Name: VESP211_R002_1116 Revision: March 2016 This product designed and manufactured in Ottawa, Illinois USA using domestic and imported parts by International Headquarters
More informationHardware Installation Guide Installation (x3350)
Title page Nortel Application Gateway 2000 Nortel Application Gateway Release 6.3 Hardware Installation Guide Installation (x3350) Document Number: NN42400-300 Document Release: Standard 04.03 Date: January
More informationFeatures and Benefits. User-friendly LCD panel for easy installation Adjustable termination and pull high/low resistors.
NPort 5400 Series 4-port RS-232/422/485 serial device servers Features and Benefits User-friendly LCD panel for easy installation Adjustable termination and pull high/low resistors Socket modes: TCP server,
More informationIndustrial 8-Port 10/100/1000T 802.3af/at PoE + 2-Port 100/1000X SFP Managed Switch with Wide Operating Temperature
Industrial 8-Port 10/100/1000T 802.3af/at PoE + 2-Port 100/1000X SFP Managed Switch with Wide Operating Temperature IGS-10020PT / IGS-10020HPT Quick Installation Guide Version 1.0 Table of Contents 1.
More informationecov-110 User s Manual (V0.9f_Eng)
ecov-110 User s Manual (V0.9f_Eng) 1. Product Introduction 2. Windows Utility 3. Web Console 4. Command Mode 5. Connection Test Appendix A. ecov-110 Firmware Upgrade Appendix B. ecov-110 Serial Advanced
More informationInternational Headquarters. European Headquarters
VLINX VESP211 SERIAL SERVER Document Name: VESP211_R002_0613 Revision: 2.0 -- February 2013 This product designed and manufactured in Ottawa, Illinois USA using domestic and imported parts by International
More informationCoBox-FL/CoBox-FL-IAP User Guide. Part Number Revision E 8/03
CoBox-FL/CoBox-FL-IAP User Guide Part Number 900-285 Revision E 8/03 Copyright and Trademark 2003, Lantronix. All rights reserved. No part of the contents of this book may be transmitted or reproduced
More informationNPort 5000AI-M12 Series
NPort 5000AI-M12 Series Railway 1, 2, and 4-port RS-232/422/485 serial device servers Features and Benefits Speedy 3-step web-based configuration COM port grouping and UDP multicast applications Real COM/TTY
More informationECOV-110 User s Manual
ECOV-110 User s Manual 1. Product Introduction 2. Windows Utility 3. Web Console 4. Command Mode 5. Connection Test Appendix A. ECOV-110 Firmware upgrade ECOV-110 1. ECOV-110 Product Introduction: 1.1.
More information5600 Series. 8 and 16-port Serial Device Servers. Features. Internet Readiness for up to 16 Serial Devices
5600 Series 8 and 16-port Features Up to 16 ports supporting RS-22, RS-422, or RS-485 operation Compact desktop model or standard 19-inch rackmount model Auto-detecting 10/100 Mbps Ethernet 15 KV ESD surge
More informationDT Desktop Series
5600-8-DT Desktop Series Compact 8-port Serial s Features 8 ports supporting RS-232, RS-422, or RS-485 operation Compact desktop size Auto-detecting 10/ 100 Mbps Ethernet 15 KV ESD surge protection for
More informationMODBUS/TCP TO SIEMENS G110/G120/MM440 APPLICATION
ICP PANEL-TEC MICROBRIDGE INSTALLATION AND OPERATION GUIDE MODBUS/TCP TO SIEMENS G110/G120/MM440 APPLICATION Revision History Revision Date Author Comments 000 02 June 2009 David Walker Initial release.
More informationinstallation manual SALES AND ADMINISTRATION (toll free)
installation manual SALES AND ADMINISTRATION 800.637.2645 (toll free) 217.442.0611 sales@timeomatic.com TECHNICAL SUPPORT 866.637.2645 (toll free) service@timeomatic.com www.watchfiresigns.com Quick Start-Up
More informationMotortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision
Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision 1.03.00 Motortronics / Phasetronics 1600 Sunshine Drive Clearwater, Florida 33765 Tel: 727-573-1819 Fax: 727-573-1803
More informationNET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2
NET101 RS232 / RS422 / RS485 to Ethernet Converter User s Manual Version 1.2 Copyright Information Copyright 2004-2005, Mega System Technologies, Inc. All rights reserved. Reproduction without permission
More informationIDS-141A/181A. Industrial 4-port/8-port slim type serial to Ethernet device server. Features. Introduction. DS-Tool
4/8 Port v1.5 / Dec, 2011 Features 4-port/8-port slim type serial to Ethernet device server Operating Modes : Virtual Com, Tunnel, TCP Server, TCP Client, UDP Multiple host devices : 5 host devices: Virtual
More informationACE PLUS CORP. APCON100 series Operation Manual RS-232 to Ethernet Converter
APCON100 series Operation Manual RS-232 to Ethernet Converter Page 1 of 24 APCON100 series Operation Manual Index Chapter 1 Specifications 2 Chapter 2 Introduction 3 Chapter 3 Easy Installation 4 Chapter
More informationArm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications
IA260 Series Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA Features and Benefits Cirrus Logic EP9315 Arm9 CPU, 200 MHz 128 MB RAM onboard, 32 MB flash disk
More informationEthernet-232 User s Manual
Ethernet-232 User s Manual Design Gateway Co., Ltd. Rev 1.0 (PD0503-6-00-01E) *** Please read this manual carefully before using Ethernet-232 *** Revision History Revision Date Detail of change 1.0 28
More informationDS-100. User s Manual. Signal bridge between RJ-45 and RS-232. Version 2.0
DS-100 Signal bridge between RJ-45 and RS-232 User s Manual Version 2.0 Copyright and Disclaimer Version 2.0 This guide is written for initial firmware version or later. Copyright & Disclaimer No part
More informationUsing the Lantronix WiBox with the CR800 or CR1000
5 Gould Road, PO Box 2155 New London, NH 03257 USA Voice: (603) 526-9800 info@canarysystems.com www.canarysystems.com Using the Lantronix WiBox with the CR800 or CR1000 Application Note #23 Revision 02/03/2017
More informationICP PANEL-TEC PEX3000 II
ICP PANEL-TEC PEX3000 II MODBUS PORT EXPANDER INSTALLATION AND OPERATION GUIDE REVISION HISTORY Revision Date Author Comments 000 29 Aug 2008 Keira Majors Initial release. 001 16 Sep 2008 David Walker
More informationRS-232/422/485 Over IP Adapter
RS-232/422/485 Over IP Adapter 1 port RS-232/422/485 Over IP Adapter NETRS2321E Actual product may vary from photo FCC Compliance Statement This equipment has been tested and found to comply with the limits
More informationEtherSeries Modbus Gateway EMB-2 User s Guide
EtherSeries Modbus Gateway EMB-2 User s Guide Revised March 25, 2004 Firmware Version 1.4 FCC Statement This device complies with the limits for a Class B digital device, pursuant to Part 15 of the FCC
More information1 port RS-232 Device Server
1 port RS-232 Device Server Ethernet RJ45 1 Port Transmit and receive and Ethernet Link and 100/10M LED drive. 10/100 Mbps, auto MDI/MDIX Gateway IP address Serial Interface 1 Port 15 KV ESD protection
More informationNote: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function
Appendix A Specifications This appendix lists the specifications for the BANDIT family of products. Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200
More informationTCP/IP Converter. EX-9132 Operation Manual for 8051 Series
TCP/IP Converter EX-9132 Operation Manual for 8051 Series First Edition, March 2005 Table of Contents 1. Introduction 3 Overview 4 Package Checklist 5 Block Diagram 6 Features 7 Product Specifications
More informationOperation Manual of EX9132CST-Series
Operation of EX9132CST-Series Serial to TCP/IP Converter (EX9132CST-2/ EX9132CST-RS485/ EX9132C-RS232) Version 1.0.0. 30.03.2017 Table of Contents 1 Introduction... 4 2 Overview... 5 2. 1 Package Checklist...
More informationOperation Manual of EX-9132C-2. Serial to TCP/IP Converter
Operation Manual of EX-9132C-2 Serial to TCP/IP Converter Version 1.1.0, 25th Jan. 2010 Table of Contents 1. Introduction 3 Overview 4 Package Checklist 4 Block Diagram 5 Features 6 Product Specifications
More informationLM300 Manager User Manual. Document Version: 1.1 LM300 Firmware Version: Bluetooth Firmware Version:
LM300 Manager User Manual Document Version: 1.1 LM300 Firmware Version: 2.0.1 Bluetooth Firmware Version: 7.5.4279 LM300 Bluetooth Ethernet Access Point LM300 Manager User Manual i Revision Date Description
More informationTotal Control System Application Guide
Total Control System Application Guide PPP Dial-in / IP Network / Channelized T1 HiPer ARC / HiPer DSP Part No. 1.024.1804-00 Version Number 1.0 Total Control System Application Guide Point-to-Point Protocol
More informationUser Manual Anybus Serial Server
User Manual Anybus Serial Server Rev. 1.20:1 HMS Industrial Networks AB Germany Japan Sweden U.S.A UK + 49-721 - 96472-0 + 81-45 - 478-5340 + 46-35 - 17 29 20 + 1-773 - 404-3486 + 44 (0) 1908-359301 ge-sales@hms-networks.com
More informationTRP-C37M User s Manual
TRP-C37M User s Manual MODBUS TCP to RTU/ASCII Gateway Printed OCT. 2010 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172
More informationFAST ETHERNET RACKMOUNT WEB-SMART SWITCH USER MANUAL
FAST ETHERNET RACKMOUNT WEB-SMART SWITCH USER MANUAL MODEL 505093 WITH OPTIONAL GIGABIT PORTS INT-505093-UM-0906-01 TABLE OF CONTENTS section page 1. Introduction & Features...3 2. Hardware Installation...3
More informationNetCom Plus 811 POE. Contact Online. More Pictures. Click on the thumbnails for the large picture. Overview
VS Vision Systems GmbH / Part Number 6681 NetCom Plus 811 POE Features Controls 8 RS232 devices located virtually anywhere via Ethernet, WLAN or Internet Supply via Power over Ethernet 802.3af LAN 1000/100/10
More informationSelect a Data Communication Interface
Printer Setup and Operation Select a Data Communication Interface Select a Data Communication Interface You may connect your print engine to a computer using one or more of the available connections. The
More informationProjectorNetTM Adapter Setup Guide
ProjectorNetTM Adapter Setup Guide Adapter networking 009-1301-00 *009-1301-00* Declaration of Conformity Declaration of Conformity Manufacturer: InFocus Corporation, 27500 SW Parkway Avenue, Wilsonville,
More informationES-446 PoE ETHERNET TO SERIAL DEVICE SERVER Ethernet 1 Port RS232 Power Over Ethernet PoE CONNECT, CONFIGURE, CONTROL YOUR SERIAL DEVICES.
GB AEOF 00031/11 ES-446 PoE ETHERNET TO SERIAL DEVICE SERVER Ethernet 1 Port RS232 Power Over Ethernet PoE CONNECT, CONFIGURE, CONTROL YOUR SERIAL DEVICES Features 1 Port RS-232 with Power over Ethernet
More informationPCL Port RS-232 Interface Card
PCL-858 8-Port RS-232 Interface Card Copyright Notice This documentation and the software included with this product are copyrighted 2001 by Advantech Co., Ltd. All rights are reserved. Advantech Co.,
More informationPre-Installation Information--S8700 IP Connect
Pre-Installation Information--S8700 IP Connect Avaya S8700 Media Server for IP Connect Configuration This job aid provides information, hardware, and tools required for installing an Avaya S8700 Media
More informationProduct Manual. 8-Port RS-232 USB to Serial Adapter Data Control Box. Coolgear, Inc. Version 1.1 September 2017 Model Number: USB-8COM
8-Port RS-232 USB to Serial Adapter Data Control Box Product Manual Coolgear, Inc. Version 1.1 September 2017 Model Number: USB-8COM 2 USB-8COM Product Manual Revision History Revision Date Author Comments
More informationABLELink. Modbus Gateway MB5000 Series User s Manual
ABLELink MB5000 Series User s Manual Version 1.1 Updated in March, 2010 TEL: 886-3-5508137 FAX: 886-3-5508131 http://www.atop.com.tw Table of Contents Table of Contents... 2 Introduction... 4 Features...
More informationNetCom Plus 411 (NetCom 411, NetCom 411 PRO)
VS Vision Systems GmbH / Part Number 6670 Main Features Ethernet to serial 4 port RS232 Virtual Com Port driver for Windows Secure Server with latest SSL/AES-256 encryption Operation in Driver Mode, TCP/IP
More informationNetCom Plus 111 (NetCom 111)
VS Vision Systems GmbH / Part Number 6640 Main Features Ethernet to serial 1 port RS232 Virtual Com Port driver for Windows Secure Server with latest SSL/AES-256 encryption Operation in Driver Mode, TCP/IP
More information8 TS4-DDH T i g e r S t o p M a n u a l D a t a D o w n l o a d i n g. May 2006 Version 3.5 ~ 4.72 Hardware
8 TS4-DDH T i g e r S t o p M a n u a l D a t a D o w n l o a d i n g May 2006 Version 3.5 ~ 4.72 Hardware Installation & User s Guide ESC Ethernet-to-Serial Converter SX Serial Extender IMPORTANT! TigerStop
More informationMGate 5105-MB-EIP Series
MGate 5105-MB-EIP Series 1-port Modbus RTU/ASCII/TCP-to-EtherNet/IP gateways Features and Benefits Protocol conversion between Modbus and EtherNet/IP Supports EtherNet/IP Scanner/Adapter Supports Modbus