CCIE Data Center Storage Networking. Fibre Channel Switching Configuration. Nexus 5500UP FC Initialization Allocate interfaces as type FC
|
|
- Abigayle Atkins
- 5 years ago
- Views:
Transcription
1 CCIE Data Center Storage Networking Fibre Channel Switching Configuration Nexus 5500UP FC Initialization Allocate interfaces as type FC slot 1 port type fc FC must start at top of module and count down Requires config save & reload Enable feature fcoe FC (and FCoE) features are not activated until FC_FEATURES_PKG is checked out
2 Fibre Channel Interfaces Like Ethernet, FC Auto Negotiation is on by default Port Type Trunk Mode Speed In cases where negotiation fails, static config is switchport mode [F FL E SD NP ] switchport trunk mode [on off auto] switchport speed [ ] Verified as show interface [brief] Fibre Channel Expansion Ports E_port - Expansion Port Inter Switch Link (ISL) On certain MDS line cards, E cannot be autonegotiated E_port requires dedicated rate-mode switchport rate-mode dedicated Similar to how port groupings work on Nexus 7K All ports on Nexus 5500 are dedicated rate mode
3 FC Trunking Expansion Ports TE_port Trunking Expansion Extended ISL, analogous to an 802.1Q Trunk Trunk negotiation is on for E ports trunk protocol enable show trunk protocol Manually configured as combination of switchport mode [e auto] switchport trunk mode [on auto] There is no switchport mode te command Like Ethernet trunks, all VSANs are allowed switchport trunk allowed vsan Verified as show interface fc1/1 [trunk vsan] SAN Port Channels Used to aggregate the bandwidth of physical links Ethernet PCs and SAN PCs use the same number space Created with link level channel-group 1 New members added with link level channel-group 1 force Port Channeling Protocol (PCP) enabled with PC link level channel mode active interface Port-Channel in MDS interface SAN-Port-Channel in Nexus Verified as show [san-]port-channel summary
4 Virtual SANs (VSANs) Use to segment Fabric Services into logical SAN Islands FLOGI, FC Domain, FC Name Server, Zoning, Aliases, etc. Configured as vsan database vsan 10 vsan 10 interface fc1/1 VSANs and EISLs All VSANs allowed on trunk ports by default Remotely un-configured VSANs automatically pruned off of trunks Similar to Ethernet Bridge Assurance To avoid merging fabrics, VSANs should be pruned manually switchport trunk allowed vsan FC Fabric Services Fibre Channel networks are connection oriented Nodes must first register with the control plane of the fabric before sending any traffic FC Fabric Services include FC Domain Principle Switch Election & assignment of Domain IDs FSPF Fabric Routing between Domain IDs FLOGI End station registers with the fabric and are assigned FCID FC Name Services / Directory Services Distributes FCID to pwwn/wwpn mappings through Fabric Zoning Controls which Initiators can talk to which Targets
5 FC Domain Principle Switch assigns Domain IDs to Fabric PS Election Based on lowest priority and SWWN Modified as fcdomain priority 1 vsan 1 Domain ID selection Dynamic from PS by default Static as fcdomain domain 0x51 [preferred static] Preferred requests Domain ID but will join without the assignment Static requests Domain ID and isolates itself without the assignment FC Domain FC Domain process restart Graceful as fcdomain restart vsan 1 Forced as fcdomain restart disruptive vsan 1 Not recommended Verified as show fcdomain [vsan] show fcdomain domain-list [vsan]
6 Fabric Shortest Path First Used to build an SPT through the fabric Similar logic to OSPF & IS-IS Domain-ID is the Node ID in the SPT Occurs automatically on a per-vsan basis Can be modified as Global fspf config vsan 1 Interface fspf [cost dead-interval hello-interval passive retransmit-interval] Verified as show fspf [database interface] [vsan] Fabric Login (FLOGI) All Initiators and Targets must FLOGI before sending any data into the Fabric Verified as show flogi database No configuration needed No FLOGI indicates a basic link-level negotiation problem
7 FC Name Services FCNS (AKA Directory Services) keeps a mapping of FCIDs to pwwns/wwpns Analogous to the IP ARP Cache End devices register with the FCNS after FLOGI show flogi database only shows local Initiators & Targets show fcns database shows everyone in the Fabric If Node did FLOGI but is not in everyone s FCNS, indicates the Fabric is broken E.g. VSAN is isolated, EISL allowed list is wrong, etc. Zoning Controls which Initiators can talk to which Targets Analogous to an ACL in the LAN/WAN world Zoning is required, not optional Default zone policy is to deny Can be changed to permit as zone default-zone permit vsan 1 system default zone
8 Soft vs. Hard Zoning Soft Zoning Initiator registers with FCNS to get Zoning Zoning enforced in the control plane but not data plane Initiator could manually mount the wrong Target Hard Zoning Initiator registers with FCNS to get Zoning Zoning enforced in the control plane and the data plane Initiator cannot manually mount the wrong Target NX-OS / SAN-OS runs Hard Zoning by default Zone vs. Zoneset Zone is used to create a mapping between pwwns/wwpns, FCIDs, Aliases, Interface, Domain-ID, etc. Zones are grouped together in a Zoneset I.e. Zoneset is the ACL, Zone is the ACE Zoneset is applied to the VSAN and then activated Makes the Full Zoneset become the Active Zoneset Zoneset must be re-activated after each change
9 Full vs. Active Zoneset Only one Zoneset per VSAN can be Active in the Fabric at a time Same logic as one ACL per interface per direction Full Zoneset is the one in the configuration Active Zoneset is the one being enforced in the Fabric By default only the Active Zoneset is advertised, not the Full Zoneset Can result in misconfigured or Isolated Fabric Zoning Configuration & Verification show zone status vsan 1 Display zone mode and default action (permit or deny) show zone Display full zone info show zone active Display the currently active zones show zoneset Display full zoneset info show zoneset active Display the currently active zoneset
10 Zoning Configuration & Verification clear zone database vsan 1 Deletes the local full zone but not the active one zoneset distribute full vsan 1 In global config enables full distribution when new E ports come up zoneset distribute vsan 1 In exec mode force the distribution of the full zoneset FC Aliases Zoning based on pwwn/wwpn is error-prone Zoning errors can be catastrophic to the Fabric FC Aliases give user-friendly names to WWNs, FCIDs, etc. Analogous to DNS in IP Configured as fcalias name Can be advertised through Zoneset distribution zoneset distribute vsan 1
11 Basic vs. Enhanced Zoning By default the Full Zoneset is local and the Active Zoneset is Fabric-wide Order of operations errors can corrupt the Active Zoneset Analogous to VTP deleting all your Ethernet VLANs Enhanced Zoning prevents this by locking the Fabric Ensures that people don t accidentally overwrite each other Using Enhanced Zoning Admin logs into any switch in the Fabric and starts to configure Zoning Lock is advertised to all switches in the Fabric Other admins cannot edit Zoneset until lock is released Lock is released by committing the Zoneset Configured as zone mode enhanced vsan system default zone mode enhanced
12 FC Device Aliases FC Aliases are locally significant Can be distributed through manual Zoneset distribution Still prone to becoming unsynchronized through the Fabric Device Aliases solve this problem Device Aliases serve the same purpose as FC Aliases Bind a pwwn/wwpn to a user-friendly name Difference is that the binding is advertised to the Fabric Using Device Aliases Device Aliases are advertised like Enhanced Zoning Device Alias session is created and lock is advertised to the Fabric Changes are made and committed Aliases are advertised through CFS and lock is removed Configured as device-alias database
13 Q&A
CCIE Data Center Storage Networking. Fibre Channel Switching
CCIE Data Center Storage Networking Fibre Channel Switching What is Fibre Channel? From a high level, replaces SCSI disk cable with a network From this To this What is Fibre Channel? Protocol stack primarily
More informationConfiguring Fibre Channel Interfaces
This chapter contains the following sections:, page 1 Information About Fibre Channel Interfaces Licensing Requirements for Fibre Channel On Cisco Nexus 3000 Series switches, Fibre Channel capability is
More informationConfiguring FCoE NPV. Information About FCoE NPV. This chapter contains the following sections:
This chapter contains the following sections: Information About FCoE NPV, page 1 FCoE NPV Model, page 3 Mapping Requirements, page 4 Port Requirements, page 5 NPV Features, page 5 vpc Topologies, page
More informationConfiguring a Dual Fabric SAN Environment
CHAPTER 10 Dual fabric SAN environments are an important configuration requirement. You can use CSM modules in combination with the Inter-VSAN Routing (IVR) feature to operate across two isolated fabrics.
More informationConfiguring PortChannels
This chapter provides information about PortChannels and how to configure the PortChannels. Finding Feature Information, page 1 Information About PortChannels, page 1 Prerequisites for PortChannels, page
More informationTroubleshooting Cisco Data Center Unified Fabric
Troubleshooting Cisco Data Center Unified Fabric Number: 642-980 Passing Score: 800 Time Limit: 120 min File Version: 1.0 http://www.gratisexam.com/ Exam A QUESTION 1 Which command displays the traffic
More informationConfiguring and Managing Zones
CHAPTER 19 Zoning enables you to set up access control between storage devices or user groups. If you have administrator privileges in your fabric, you can create zones to increase network security and
More informationF Commands CHAPTER. Send documentation comments to
CHAPTER 7 The commands in this chapter apply to the Cisco MDS 9000 Family of multilayer directors and fabric switches. All commands are shown here in alphabetical order regardless of command mode. Please
More informationDCNX5K: Configuring Cisco Nexus 5000 Switches
Course Outline Module 1: Cisco Nexus 5000 Series Switch Product Overview Lesson 1: Introducing the Cisco Nexus 5000 Series Switches Topic 1: Cisco Nexus 5000 Series Switch Product Overview Topic 2: Cisco
More informationContents. FCoE commands 0
Contents FCoE commands 0 FCoE mode commands 0 display fcoe-mode 0 fcoe-mode 0 VFC interface commands 2 bandwidth 2 bind interface 2 default 3 description 4 display interface vfc 5 fc mode 8 interface vfc
More informationIVR Zones and Zonesets
Information about, page 1 Default Settings, page 3 Licensing Requirements, page 3 Guidelines and Limitations, page 3 Configuring, page 4 Verifying IVR Configuration, page 11 Feature History, page 12 Information
More informationMDS 9020 Switch Interoperability
CHAPTER 10 This chapter describes how to connect the Cisco MDS 9020 fabric switch to a third-party switch, and it includes the following sections: Specifications, page 10-5 Expected Topology Behavior,
More informationCisco Nexus 5600 Series NX-OS SAN Switching Configuration Guide, Release 7.x
Cisco Nexus 5600 Series NX-OS SAN Switching Configuration Guide, Release 7.x Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000
More informationVerified Scalability for Cisco Nexus 5500 Series NX-OS Release 7.0(3)N1(1)
Verified Scalability for 5500 Series NX-OS Release 7.0(3)N1(1) This chapter contains the following sections: Overview of Verified Scalability, page 1 Verified Scalability for a Layer Switching Deployment,
More informationCisco MDS NX-OS Release 6.2Configuration Limits 2
Cisco MDS NX-OS Release 6.2 Configuration Limits Cisco MDS NX-OS Release 6.2Configuration Limits 2 Switch Level Fibre Channel Configuration Limits for Cisco MDS 9000 Series Switches 2 Fabric Level Fibre
More informationTroubleshooting Zones and Zone Sets
CHAPTER 14 This chapter describes how to identify and resolve problems that might occur while implementing zones and zone sets on switches in the Cisco MDS 9000 Family. It includes the following sections:
More informationHP FlexFabric 5700 Switch Series
HP FlexFabric 5700 Switch Series FCoE Command Reference Part number: 5998-6675 Software version: Release 2416 Document version: 6W100-20150130 Legal and notice information Copyright 2015 Hewlett-Packard
More informationCisco Nexus 5000 Series NX-OS SAN Switching Configuration Guide
Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883 Text Part Number: OL-xxxxx-xx THE
More informationAdvanced Fibre Channel Features
This chapter describes how to configure advanced Fibre Channel features. This chapter includes the following sections: and Concepts, page 1 and Concepts Fibre Channel Timeout Values You can modify Fibre
More informationConfiguring SAN Port Channel
Configuring SAN Port Channel This chapter contains the following sections: Configuring SAN Port Channels, page 1 Configuring SAN Port Channels SAN port channels refer to the aggregation of multiple physical
More informationSymbols. Numerics INDEX
INDEX Symbols *(wildcard) port security authorization 18-5 Numerics 16-port modules BB_credits 10-12 LEDs 10-15 preserving configurations 7-7 See also switching modules 32-port modules BB_credits 10-12
More informationManaging FLOGI, Name Server, FDMI, and RSCN Databases, page 1
Managing FLOGI, Name Server, FDMI, and RSCN Databases This chapter describes how to configure and manage FLOGI, name server FDMI, and RSCN databases. This chapter includes the following sections:, page
More informationNexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example
Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example Document ID: 116248 Contributed by Jim Hicks and Shelley Bhalla, Cisco TAC Engineers. May 01, 2014 Contents Introduction Prerequisites
More informationConfiguring Cisco Unified FEX Nexus 2348UPQ with Fiber Channel Interfaces
Configuring Cisco Unified FEX Nexus 2348UPQ with Fiber Channel Interfaces This chapter provides details about configuring native fiber channels on Cisco Nexus 2348UPQ FEX, and contains the following sections:
More informationContents. FCoE commands 1
Contents FCoE commands 1 FCoE mode commands 1 display fcoe-mode 1 fcoe-mode 1 VFC interface commands 3 bandwidth 3 bind interface 3 default 5 description 5 display interface vfc 6 fc mode 9 interface vfc
More informationCisco MDS 9000 Series Fabric Configuration Guide, Release 8.x
Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883 2018 Cisco Systems, Inc. All rights
More informationConfiguring and Managing Zones
CHAPTER 5 Zoning enables you to set up access control between storage devices or user groups. If you have administrator privileges in your fabric, you can create zones to increase network security and
More informationManaging FLOGI, Name Server, FDMI, and RSCN Databases
CHAPTER 17 Managing FLOGI, Name Server, FDMI, and RSCN Databases This chapter describes the fabric login database, the name server features, and Registered State Change Notification (RSCN) information
More informationInter-VSAN Routing Configuration
CHAPTER 16 This chapter explains the inter-vsan routing (IVR) feature and provides details on sharing resources across VSANs using IVR management interfaces provided in the switch. This chapter includes
More informationConfiguring SPAN. Configuring SPAN. SPAN Sources. This chapter includes the following sections: Configuring SPAN, page 1
This chapter includes the following sections:, page 1 SPAN Sources The Switched Port Analyzer (SPAN) feature (sometimes called port mirroring or port monitoring) selects network traffic for analysis by
More informationLarge SAN Design Best Practices Using Cisco MDS 9700 and MDS 9500 Multilayer Directors
White Paper Large SAN Design Best Practices Using Cisco MDS 9700 and MDS 9500 Multilayer Directors What You Will Learn As SANs continue to grow in size, many factors need to be considered to help scale
More informationP Commands. Send documentation comments to CHAPTER
CHAPTER 17 The commands in this chapter apply to the Cisco MDS 9000 Family of multilayer directors and fabric switches. All commands are shown here in alphabetical order regardless of command mode. See
More informationQuestion: 2 Which option accurately describes the implementation of Fabre Channel domain IDs?
Volume: 186 Questions Question: 1 What is the status of FC interface associated with ethernet 1/5 indicate? A. Trunk VSAN 11 is isolated B. Inteface vfc 5 is up and running for the assigned VSAN C. Trunk
More informationTroubleshooting Distributed Device Alias Services
CHAPTER 15 Troubleshooting Distributed Device Alias Services This chapter describes how to troubleshoot and resolve problems that might occur when using device aliases. It includes the following sections:
More informationOn the Cisco Nexus 5548 Switch, Fibre Channel ports and VSAN ports cannot be configured as ingress source ports in a SPAN session.
This chapter includes the following sections:, page 1 SPAN Sources The Switched Port Analyzer (SPAN) feature (sometimes called port mirroring or port monitoring) selects network traffic for analysis by
More informationN-Port Virtualization in the Data Center
N-Port Virtualization in the Data Center What You Will Learn N-Port virtualization is a feature that has growing importance in the data center. This document addresses the design requirements for designing
More information45 10.C. 1 The switch should have The switch should have G SFP+ Ports from Day1, populated with all
Addendum / Corrigendum Dated 29/09/2017 Tender Ref No. - 236/387/DCCS/2010/IREDA/1 Dated: 22/09/2017 Name of Project - Supply Installation and Support Services of Data centers S. No. Document Reference
More informationHP 6125XLG Blade Switch
HP 6125XLG Blade Switch FCoE Configuration Guide Part number: 5998-3726 Software version: Release 2306 Document version: 6W100-20130912 Legal and notice information Copyright 2013 Hewlett-Packard Development
More informationMDS 9000 Core with Brocade 3900/12000 Edge Topology
CHAPTER 6 MDS 9000 Core with Brocade 3900/12000 Edge Topology This chapter describes how to set up a basic core-edge topology with one MDS 9000 switch configured for interop mode 1 at the core and two
More informationUCS Engineering Details for the SAN Administrator
UCS Engineering Details for the SAN Administrator Craig Ashapa 2 First things first: debunking a myth Today (June 2012 UCS 2.02m) there is no FCoE northbound of UCS unless you really really really want
More informationHPE Knowledge Article
HPE Knowledge Article HPE FlexFabric 5900CP Switch Series - JG838A Switch Fiber Channel Configuration and Troubleshooting Cheatsheet Article Number mmr_sf-en_us000005602 Environment Working FC config with
More informationConfiguring and Managing Zones
Send documentation comments to mdsfeedback-doc@cisco.com CHAPTER 30 Zoning enables you to set up access control between storage devices or user groups. If you have administrator privileges in your fabric,
More informationCisco Nexus 9000 Series NX-OS FC NPV Configuration Guide, Release 9.x
Cisco Nexus 9000 Series NX-OS FC NPV Configuration Guide, Release 9.x First Published: 2018-07-11 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com
More informationPracticeTorrent. Latest study torrent with verified answers will facilitate your actual test
PracticeTorrent http://www.practicetorrent.com Latest study torrent with verified answers will facilitate your actual test Exam : 642-980 Title : Troubleshooting Cisco Data Center Unified Fabric (DCUFT)
More informationDell Networking MXL / PowerEdge I/O Aggregator with Cisco Nexus 5000 series NPV mode and Cisco MDS 9100 fabric switch Config Sheets
Dell Networking MXL / PowerEdge I/O Aggregator with Cisco Nexus 5000 series NPV mode and Cisco MDS 9100 fabric switch Config Sheets CLI Config Sheets Dell Networking Engineering November 2013 A Dell Deployment
More informationConfiguring VSANs and Interfaces
CHAPTER 3 You can achieve higher security and greater stability in Fibre Channel fabrics by using virtual storage area networks (VSANs). VSANs provide isolation among devices that are physically connected
More informationFibre Channel Gateway Overview
CHAPTER 5 This chapter describes the Fibre Channel gateways and includes the following sections: About the Fibre Channel Gateway, page 5-1 Terms and Concepts, page 5-2 Cisco SFS 3500 Fibre Channel Gateway
More informationConfiguring SPAN. Finding Feature Information. About SPAN. SPAN Sources
This chapter describes how to configure an Ethernet switched port analyzer (SPAN) to analyze traffic between ports on Cisco NX-OS devices. Finding Feature Information, on page 1 About SPAN, on page 1 Licensing
More informationAVANTUS TRAINING PTE LTD
Implementing Cisco Data Center Unified Fabric (DCUFI) 5 Days Instructor-Led Course Overview The Implementing Cisco Data Center Unified Fabric (DCUFI) v5.0 is a five-day instructor-led training course designed
More informationDell Networking MXL and PowerEdge I/O Aggregator with Cisco Nexus 5000 series fabric mode Config Sheets
Dell Networking MXL and PowerEdge I/O Aggregator with Cisco Nexus 5000 series fabric mode Config Sheets CLI Config Sheets Dell Networking Engineering November 2013 A Dell Deployment and Configuration Guide
More informationMDS to MDS Basic Configuration with FCIP
MDS to MDS Basic Configuration with FCIP Document ID: 47100 Contents Introduction Prerequisites Requirements Components Used Conventions Background Information Configure Network Diagram Configurations
More informationConfiguring Virtual Port Channels
This chapter contains the following sections: Information About vpcs vpc Overview Information About vpcs, on page 1 Guidelines and Limitations for vpcs, on page 11 Verifying the vpc Configuration, on page
More informationFCoE Cookbook for HP Virtual Connect
Technical whitepaper FCoE Cookbook for HP Virtual Connect Version 4.45 Firmware Enhancements August 2015 Table of contents Change History 6 Purpose 7 Overview 7 Requirements and support 7 Supported Designs
More information"Charting the Course... Implementing Cisco Data Center Infrastructure (DCII) Course Summary
Description Course Summary v6.0 is a five-day instructor-led course that is designed to help students prepare for the Cisco CCNP Data Center certification and for professional-level data center roles.
More informationConfiguring Virtual Port Channels
This chapter contains the following sections: Information About vpcs, page 1 Guidelines and Limitations for vpcs, page 10 Configuring vpcs, page 11 Verifying the vpc Configuration, page 25 vpc Default
More informationConfiguring Virtual Port Channels
This chapter contains the following sections: Information About vpcs, page 1 Guidelines and Limitations for vpcs, page 10 Verifying the vpc Configuration, page 11 vpc Default Settings, page 16 Configuring
More informationVerify that your username has network-admin privileges. Assign a new network administrator password if your username has network-admin privileges.
Troubleshooting Troubleshooting, page 1 Troubleshooting Recovering a Lost Password This section describes how to recover a lost network administrator password using the console port of the switch. You
More informationCisco Nexus B22 Blade Fabric Extender for IBM
Cisco Nexus B22 Blade Fabric Extender for IBM Design and Deployment Guide 2014 Cisco IBM. All rights reserved. Page 1 Contents Introduction... 3 Network Diagram... 3 Hardware Installation... 5 Fabric Extender
More informationInteroperability Guidelines for Non-Cisco Switches
APPENDIXA Interoperability Guidelines for Non-Cisco Switches This appendix includes information on changing interop modes and describes release-specific behavior for certain versions of Brocade, McData,
More informationFCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch
FCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch Document ID: 117280 Contributed by Padmanabhan, Cisco TAC Engineer. Mar 25, 2014 Contents Introduction Prerequisites Requirements
More informationMDS 9000 Switch and McData Dual Core Topology (Interop Mode 1)
5 CHAPTER MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1) This chapter describes how to set up a basic dual-core topology with an MDS 9000 switch configured for interop mode 1 and a McData
More informationImplementing Cisco Data Center Infrastructure v6.0 (DCII)
Implementing Cisco Data Center Infrastructure v6.0 (DCII) COURSE OVERVIEW: Implementing Cisco Data Center Infrastructure (DCII) v6.0 is a five-day instructor-led course that is designed to help students
More informationTroubleshooting N-Port Virtualization
CHAPTER 9 This chapter describes how to identify and resolve problems that can occur with N-Port virtualization. It includes the following sections: Overview, page 9-1 Initial Troubleshooting Checklist,
More informationVendor: Cisco. Exam Code: Exam Name: Introducing Cisco Data Center Technologies. Version: Demo
Vendor: Cisco Exam Code: 640-916 Exam Name: Introducing Cisco Data Center Technologies Version: Demo DEMO QUESTION 1 Which two Cisco Nexus 2000-Series Fabric Extenders support connections to both Cisco
More informationConfiguring Virtual Port Channels
Configuring Virtual Port Channels This chapter describes how to configure virtual port channels (vpcs) on Cisco Nexus 5000 Series switches. It contains the following sections: Information About vpcs, page
More informationIBM Europe Announcement ZG , dated February 13, 2007
IBM Europe Announcement ZG07-0221, dated February 13, 2007 Cisco MDS 9200 for IBM System Storage switches, models 9216i and 9216A, offer enhanced performance, scalability, multiprotocol capabilities, and
More informationQ&As. Troubleshooting Cisco Data Center Infrastructure. Pass Cisco Exam with 100% Guarantee
300-180Q&As Troubleshooting Cisco Data Center Infrastructure Pass Cisco 300-180 Exam with 100% Guarantee Free Download Real Questions & Answers PDF and VCE file from: 100% Passing Guarantee 100% Money
More informationCisco MDS 9000 Series NX-OS Interfaces Configuration Guide
Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883 2017 Cisco Systems, Inc. All rights
More informationConfiguring the Fibre Channel Gateway
CHAPTER 6 This chapter describes Fibre Channel gateway configuration and includes the following sections: Before You Begin, page 6-1 Administering the Fibre Channel Gateway, page 6-1 Pre-configuration
More informationConfiguring VLANs. Understanding VLANs CHAPTER
CHAPTER 14 This chapter describes how to configure normal-range VLANs (VLAN IDs 1 to 1005) and extended-range VLANs (VLAN IDs 1006 to 4094) on the Catalyst 3750 switch. It includes information about VLAN
More informationInteroperability Limitations
CHAPTER 2 This chapter describes the restrictions and limitations imposed on specific vendor switches when working in interoperability mode. It includes the following sections: Cisco MDS 9000 Family, page
More informationCCIE Data Center Written Exam ( ) version 1.0
CCIE Data Center Written Exam (350-080) version 1.0 Exam Description: The Cisco CCIE Data Center Written Exam (350-080) version 1.0 is a 2-hour test with 80 110 questions that will validate that a data
More informationManaging Zones and Zone Sets
mdsfeedback-doc@cisco.com.send CHAPTER 3 The Fabric Manager allows you to configure and monitor zones and zone sets (groups of zones) on the Cisco 9000 switch. Zoning allows you to set up access control
More informationDeploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024 and 8024F. Dell Networking Solutions Engineering March 2012
Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024 and 8024F Dell Networking Solutions Engineering March 2012 Revisions Date Description Authors March 2012 Rev. Kevin Locklear
More informationCisco.Actualtests v by.Dragan.81q
Cisco.Actualtests.640-916.v2013-10-26.by.Dragan.81q Number: 640-916 Passing Score: 825 Time Limit: 120 min File Version: 12.5 http://www.gratisexam.com/ Exam Code: 640-916 Exam Name: Introducing Cisco
More informationConfiguring VLANs. Understanding VLANs CHAPTER
CHAPTER 12 This chapter describes how to configure normal-range VLANs (VLAN IDs 1 to 1005) and extended-range VLANs (VLAN IDs 1006 to 4094) on the switch. It includes information about VLAN membership
More informationFibre Channel Zoning
Information About, page 1 Support for in Cisco UCS Manager, page 2 Guidelines and recommendations for Cisco UCS Manager-Based, page 4 Configuring, page 4 Creating a VSAN for, page 6 Creating a New Fibre
More informationDesign and Implementations of FCoE for the DataCenter. Mike Frase, Cisco Systems
Design and Implementations of FCoE for the DataCenter Mike Frase, Cisco Systems SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA unless otherwise noted. Member companies
More information"Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary
Description Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary v6.0 is a five-day instructor-led course that is designed to help students prepare for the Cisco CCNP Data Center
More informationCisco MDS 9000 Family NX-OS Interfaces Configuration Guide
Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide Cisco MDS NX-OS Release 6.2(1) April 2013 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com
More informationCONNECTRIX MDS-9250I SWITCH
Specification Sheet MDS-9250i CONNECTRIX MDS-9250I SWITCH Multipurpose Switch The Connectrix MDS-9250i Multilayer Switch offers up to forty 16 Gigabit per second (Gb/s) Fibre Channel ports, two 1/10 Gigabit
More informationConfiguring VLANs. Understanding VLANs CHAPTER
CHAPTER 10 This chapter describes how to configure normal-range VLANs (VLAN IDs 1 to 1005) and extended-range VLANs (VLAN IDs 1006 to 4094) on the switch. It includes information about VLAN membership
More informationConfiguring VLANs. Understanding VLANs CHAPTER
CHAPTER 11 This chapter describes how to configure normal-range VLANs (VLAN IDs 1 to 1005) and extended-range VLANs (VLAN IDs 1006 to 4094) on your Catalyst 3550 switch. It includes information about VLAN
More informationExam Questions
Exam Questions 640-916 DCICT Introducing Cisco Data Center Technologies https://www.2passeasy.com/dumps/640-916/ 1. An engineer is implementing an FCoE enabled port-channel trunk between two Nexus 5000
More informationDesigning SAN Using Cisco MDS 9000 Series Fabric Switches
White Paper Designing SAN Using Cisco MDS 9000 Series Fabric Switches September 2016 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 1 of 15 Contents What You
More informationFibre Channel Specialist Lab
Fibre Channel Specialist Lab 203.21 Enterprise Fabric Suite Zoning Operation Objective: This lab will demonstrate the configuration and management of zoning in a QLogic fabric. Unless noted, all operations
More informationCisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.0(4c)
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.0(4c) Release Date: April 5, 2011 Part Number: F0 This document describes the caveats and limitations for switches in the Cisco MDS 9000
More informationImplementing Smart Zoning On IBM Cisco SANs
Implementing Smart Zoning On IBM Cisco SANs What Is Smart Zoning Zoning on any SAN is used to limit what SAN devices can see other devices. This makes SANS easier to administer and limits the impact on
More informationGetting Started. Enabling SSH
This chapter provides an overview of the basic configurations that need to be completed before getting started with IOA-specific configurations: Enabling SSH, page 1 Enabling CFS, page 2 IP Access Lists,
More informationCONNECTRIX MDS-9132T, MDS-9396S AND MDS-9148S SWITCHES
SPECIFICATION SHEET Connectrix MDS Fibre Channel Switch Models CONNECTRIX MDS-9132T, MDS-9396S AND SWITCHES The Dell EMC Connecrix MDS 9000 Switch series support up to 32Gigabit per second (Gb/s) Fibre
More informationFC-SP and DHCHAP. Fibre Channel Security Protocol. Send documentation comments to CHAPTER
30 CHAPTER Fibre Channel Security Protocol () capabilities provide switch-switch and host-switch authentication to overcome security challenges for enterprise-wide fabrics. Diffie-Hellman Challenge Handshake
More informationConfiguring Users and Common Roles
Send documentation comments to mdsfeedback-doc@cisco.com. 26 CHAPTER Configuring Users and Common Roles The CLI and SNMP use common roles in all switches in the Cisco MDS 9000 Family. You can use CLI to
More informationFibre Channel Networking for the IP Network Engineer and SAN Core Edge Design Best Practices Chad Hintz Technical Solutions Architect BRKVIR-1121
Fibre Channel Networking for the IP Network Engineer and SAN Core Edge Design Best Practices Chad Hintz Technical Solutions Architect BRKVIR-1121 Session BRKVIR-1121 Abstract Fibre Channel Networking for
More informationThis appendix covers the following topics: Understanding the Concepts of Storage Networking Understanding the Storage Networking Protocols
This appendix covers the following topics: Understanding the Concepts of Storage Networking Understanding the Storage Networking Protocols Integrating SAN in Cisco Multilayer Switched Networks Implementing
More informationCisco Configuring Cisco Nexus 7000 Switches v3.1 (DCNX7K)
Course Overview View Course Dates & Register Today This course is designed for systems and field engineers who configure the Cisco Nexus 7000 Switch. This course covers the key components and procedures
More informationHP StorageWorks Fabric OS 6.1.2_cee1 release notes
HP StorageWorks Fabric OS 6.1.2_cee1 release notes Part number: 5697-0045 First edition: June 2009 Legal and notice information Copyright 2009 Hewlett-Packard Development Company, L.P. Copyright 2009 Brocade
More informationConfiguring FCoE NPV. FCoE NPV Overview. FCoE NPV Benefits
FCoE NPV Overview This chapter describes how to configure Fiber Channel over Ethernet (FCoE) N-port Virtulization (NPV) on Cisco NX-OS devices. FCoE NPV Overview, on page 1 VNP Ports, on page 3 Licensing
More informationVendor: Cisco. Exam Code: Exam Name: CCIE Data Center Written Exam. Version: Demo
Vendor: Cisco Exam Code: 351-080 Exam Name: CCIE Data Center Written Exam Version: Demo QUESTION 1 FabricPath brings the benefits of routing protocols to layer 2 network Ethernet environments. What are
More informationCisco Exam Questions & Answers
Cisco 642-997 Exam Questions & Answers Number: 642-997 Passing Score: 900 Time Limit: 120 min File Version: 36.4 http://www.gratisexam.com/ Cisco 642-997 Exam Questions & Answers Exam Name: Implementing
More informationConfiguring Enhanced Virtual Port Channels
This chapter contains the following sections: Information About Enhanced vpcs, page 2 Licensing Requirements for Enhanced vpc, page 4 Configuring Enhanced vpcs, page 4 Verifying Enhanced vpcs, page 5 Enhanced
More information