NEW! Roc LC Columns: The Reliable Cornerstone for Your LC Lab
|
|
- Owen Summers
- 5 years ago
- Views:
Transcription
1 LC s NEW! Roc LC s: The Reliable Cornerstone for Your LC Lab Conventional columns built for solid performance, exceptional value, and compact storage. Pure Chromatography
2 Roc LC s Conventional column built to be the cornerstone for your lab; pressure rated for any 00 bar system. Solid and reliable delivers the peak shape, reproducibility, ruggedness, and performance you demand. Exceptional value for routine analyses and large-volume workflows high-purity, fully porous silica backed by quality manufacturing features a variety of phases to fit most methods. Ideal for a wide range of applications from food to pharma; 5 phases cover 98% of USP methods. Newly designed minimal packaging for compact storage download serial #-specific certificates of analysis at Get more of what you want, and less of what you don t, with Roc LC columns from Restek. rder today at Roc Family of LC Phases C8 C8 Phenyl-Hexyl Cyano Silica N C H CH Si CH CH Si CH CH Si CH CH Si CH Si C8 Phenyl-Hexyl USP Phase Code L L7 L L0 L Stationary Phase Category C8, octadecylsilane C8, octylsilane phenyl cyano bare silica Ligand Type monomeric C8 monomeric C8 phenyl-hexyl cyanopropyl n/a Particle Size μm or 5 μm, spherical μm or 5 μm, spherical μm or 5 μm, spherical μm or 5 μm, spherical μm or 5 μm, spherical Pore Size 00 Å 00 Å 00 Å 00 Å 00 Å Surface Area 00 m /g 00 m /g 00 m /g 00 m /g 00 m /g Carbon Load 0% % 5% 8% n/a End-Cap yes yes yes yes n/a ph Range.5 to to to to to 8.0 Maximum Temperature 80 C 80 C 80 C 80 C 80 C Cyano
3 Roc n with These Dependable LC s Figure : ver,000 injections and Roc columns will still offer reliable performance, regardless of which dimension your method calls for % Efficiency vs # of Injections Roc 5 µm 75 bar x.6 mm 50 x.6 mm 50 x.6 mm 00 x.0 mm 50 x.0 mm 50 x.0 mm Figure : Add a Roc LC guard to further extend the life of your analytical column without impacting your retention, peak shape, or efficiency. Peaks (mg/ml). Uracil 0.0. Toluene.00. Naphthalene Biphenyl 0.06 With guard column : Roc C8 (cat.# 95565); Dimensions: 50 mm x.6 mm ID; ; Pore Size: 00 Å; Guard : Roc C8 0 mm,.0 mm ID, 5 µm (cat.# 95500); Temp.: 0 C; : Custom mix; Diluent: 50:50 Acetonitrile:water; Inj. Vol.: µl; : A: Water, B: Acetonitrile; Gradient (%B): 0.00 min (70%), Without guard column 8.00 min (70%); Flow:.0 ml/min; : 5 nm; :. k =.7 Asymmetry =.07 Plates/m = 97,5 k =.7 Asymmetry =.097 Plates/m = 9,05 LC_GN0565 Figure : From one column to the next, one lot to the next, Roc columns provide results you can trust time and time again. Reversed Phase Peaks tr (min). p-tolunitrile.7. -Butylbenzoic acid 5..,-Dimethylanisole 7.. Mefenamic acid p-xylene 9.7 Normal Phase Peaks tr (min). Benzene.5. Nitrobenzene..,,5-Trinitrobenzene 5.5.,-Dinitrotoluene 7. 5 Lot Lot 5 Lot Lot 5 Lot Lot LC_GN056 : Roc C8 (cat.# 95565); Dimensions: 50 mm x.6 mm ID; ; Pore Size: 00 Å; Temp.: 5 C; Inj. Vol.: 5 µl; : 0.05% Formic acid in water:0.05% formic acid in acetonitrile (0:60); Flow:.0 ml/min; : 0 nm; Cell Temp: 5 C; : LC_GN056 : Roc Cyano (cat.# 956E); Dimensions: 00 mm x.0 mm ID; Particle Size: µm; Pore Size: 00 Å; Temp.: 0 C; : Inj. Vol.: µl; : Water:acetonitrile (80:0); Flow: 0.6 ml/min; : 5 nm; Cell Temp.: 0 C; :. Find the entire Roc column line and order now at
4 Roc LC s from Restek Perform Better Than or Equal To s from ther Vendors Table I: Roc LC columns offer equivalent or better peak shape, retention, and resolution compared to FPP columns from other manufacturers under identical conditions (average values, n = 5). s Analyte tr Area Height USP Tailing Asymmetry (0%) k' Plate Number Resolution Ethylparaben.5,07,609 8, ,78 Roc 5.0,869,68, ,6.5 Ethylparaben.060,,6 5, ,7 Vendor A.889,860,659, , Ethylparaben.87,6,068 9, ,706 Vendor B.07,867,09 87, ,0 9.9 Ethylparaben.76,,099 5, ,6 Vendor C.580,868,7 70, ,700.9 Ethylparaben.57,99,87 57, ,78 Vendor D 5.86,77,785 8, ,95. Vendor E Ethylparaben.87,98,6, ,8 6.89,78,5 7, ,96.7 Chromatographic conditions for Table I and Figure (USP Monograph 8, ) All columns are C8 stationary phase (5 µm, 50 x.6 mm). Conditions are as follows. Mobile phase: water:acetonitrile (:); Flow rate: ml/min; Injection volume: 5 µl; : with UV detector, 80 nm; : 00 µg/ml ethinyl estradiol and 50 µg/ml ethylparaben in water:acetonitrile (:).
5 Figure : Count on Roc LC columns from Restek for outstanding chromatographic performance. Roc LC. Ethylparaben estradiol Roc C8 (cat.# 95565) Dimensions: 50 mm x.6 mm ID Pore Size: 00 Å Temp.: 0 C Inj. Vol.: 5 µl Flow (ml/min) %A , nm LC_EX058 Vendor A. Ethylparaben estradiol Vendor A C8 Dimensions: 50 mm x.6 mm ID Pore Size: 00 Å Temp.: 0 C Inj. Vol.: 5 µl Flow (ml/min) %A , nm LC_EX05 5
6 (Continued from page 5) Figure : Count on Roc LC columns from Restek for outstanding chromatographic performance. Vendor B. Ethylparaben estradiol Vendor B C8 Dimensions: 50 mm x.6 mm ID Pore Size: 0 Å Temp.: 0 C Inj. Vol.: 5 µl Flow (ml/min) %A , nm LC_EX050 Vendor C. Ethylparaben estradiol Vendor C C8 Dimensions: 50 mm x.6 mm ID Pore Size: 80 Å Temp.: 0 C Inj. Vol.: 5 µl Flow (ml/min) %A , nm LC_EX
7 (Continued from page 6) Figure : Count on Roc LC columns from Restek for outstanding chromatographic performance. Vendor D. Ethylparaben estradiol Vendor D C8 Dimensions: 50 mm x.6 mm ID Temp.: 0 C Inj. Vol.: 5 µl Flow (ml/min) %A , nm LC_EX05 Vendor E. Ethylparaben estradiol Vendor E C8 Dimensions: 50 mm x.6 mm ID Pore Size: 00 Å Temp.: 0 C Inj. Vol.: 5 µl Flow (ml/min) %A , nm LC_EX05 7
8 Get Roc Solid Performance CH Si CH Roc C8 s (USP L).0 mm.6 mm µm s 00 mm 95E mm 956E µm s 00 mm 955E mm 9556E mm 9557E H Si Silica Roc Silica s (USP L).0 mm.6 mm µm s 00 mm 950E mm 9506E µm s 00 mm 9505E mm 95056E mm 95057E C8 CH Si CH CH C8 Si C Cyano N CH Roc C8 s (USP L7).0 mm.6 mm µm s 00 mm 95E mm 956E µm s 00 mm 955E mm 9556E mm 9557E Roc Phenyl-Hexyl s (USP L).0 mm.6 mm µm s 00 mm 955E mm 9556E µm s 00 mm 9555E mm 95556E mm 95557E Roc Cyano s (USP L0).0 mm.6 mm µm s 00 mm 956E mm 9566E µm s 00 mm 9565E mm 95656E mm 95657E Roc LC Guard Cartridges Protect your Roc LC columns with minimal effect on retention, peak shape, or efficiency. Guard column cartridges require Roc guard column holder (cat.# 58). Description qty. 0 x.0 mm cat.# Roc C8 Guard Cartridge -pk Roc C8 Guard Cartridge -pk Roc Cyano Guard Cartridge -pk Roc Phenyl-Hexyl Guard Cartridge -pk Roc Silica Guard Cartridge -pk Roc LC Guard Holder Requires separate guard column cartridges (available from Restek). Description qty. cat.# Roc LC Guard Holder for 0 x.0 mm Roc Guard Cartridges ea. 58 Replacement PEEK Ferrules for Roc LC Guard Holder Description qty. cat.# Replacement PEEK Ferrules for Roc LC Guard Holder -pk. 69 Find the entire Roc column line and order now at Pure Chromatography Questions about this or any other Restek product? Contact us or your local Restek representative ( Restek patents and trademarks are the property of Restek Corporation. (See for full list.) ther trademarks in Restek literature or on its website are the property of their respective owners. Restek registered trademarks are registered in the U.S. and may also be registered in other countries. 08 Restek Corporation. All rights reserved. Printed in the U.S.A. Lit. Cat.# GNSSB-UNV
More Chemistries, More Choices For Your Toughest Separation Challenges
Ordering Guide More Chemistries, More Choices For Your Toughest Separation Challenges Agilent InfinityLab Poroshell 120 Columns Efficiently separate the widest variety of columns Based on superficially
More informationBrownlee SPP. HPLC and UHPLC Column Solutions with Superficially Porous Particle Technology
Brownlee SPP HPLC and UHPLC Column Solutions with Superficially Porous Particle Technology Say goodbye to the limitations of traditional columns. Break free from the constraints of your Liquid Chromatography
More informationHiQ sil TM HPLC Columns
www.kromatek.co.uk KYA Technologies of Japan KYA Technologies Corporation, Tokyo, Japan established in 1998 to develop a range of HPLC products. The latest product HiQ sil HS is a high performance silica
More informationAchieve FASTERLC. with Onyx Monolithic Silica HPLC Columns. Featuring: New Onyx HD Columns for Increased Efficiency!
Achieve FASTERLC with Onyx Monolithic Silica HPLC Columns Reduce run times Increase throughput Rapidly screen dirty or complex samples Featuring: New Onyx HD Columns for Increased Efficiency! Onyx Monolithic
More informationVertiSep TM GES. HPLC Columns. VertiSep TM GES HPLC Columns
High purity Silica offer high stability, efficiency, reproducibility Moderate pore size and surface area are perfect for general purpose High carbon loading C18 offers high degree of hydrophobicity for
More informationGuard Columns ---- HPLC Column Catalog
Guard ---- Guard s selection and Use 092 Cartridge Guard E 093 Cartridge Guard Ei (Non-metal type) 094 Guard for UHPLC 096 GL Cart 098 Packed Guard, Mini Guard 099 SILFILTER TM STD C18 4 Filters, Impurity
More informationSave Money. Kromasil Columns packed by Phenomenex
Replace your Kromasil and Save Money Kromasil Columns packed by Phenomenex OPTION 1 Direct 2 Replacement Chrom-Clone Guaranteed* direct replacement to Kromasil Significant cost savings OPTION Performance
More informationuntil now. NEW ZORBAX Eclipse Plus LC Columns No LC column has ever reliably produced such symmetrical peaks for basic compounds...
No LC column has ever reliably produced such symmetrical peaks for basic compounds... until now. NEW ZORBAX Eclipse Plus LC Columns ZORBAX Eclipse Column Portfolio I can t remember the last time I achieved
More informationAgilent s Newly Expanded ZORBAX Eclipse Plus LC Column Portfolio
Agilent s Newly Expanded ZORBAX Plus LC Column Portfolio No other LC columns have ever produced such superior peaks for bases, acids, and neutrals. Enhance your productivity with new options for fast and
More informationTechnical Overview. Introduction
Performance characteristics of the Agilent 12 Infinity Series Variable Wavelength Detectors Faster results, improved sensitivity and absolute data security Technical Overview Introduction The Agilent 12
More informationOptimizing System Dispersion on the Agilent 1290 Infinity II LC
Optimizing System Dispersion on the Agilent 1290 Infinity II LC The Agilent Ultralow Dispersion Kit Technical Overview Authors Bettina Schuhn and Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany
More informationAgilent s Newly Expanded ZORBAX Eclipse Plus LC Column Portfolio
Agilent s Newly Expanded ZORBAX Eclipse Plus LC Column Portfolio No other LC columns have ever produced such superior peaks for bases, acids, and neutrals. Enhance your productivity with new options for
More informationTrue Blue Performance
True Blue Performance Improved Data, Fewer Liner Changes, and Less Downtime Exceptionally inert Sky inlet liners with state-of-the-art deactivation improve trace-level analysis even with wool and now come
More informationAgilent 1260 Infinity Diode Array Detector
Agilent 126 Infinity Diode Array Detector Features, Technical Details, Specifications and Ordering Details 1 x higher sensitivity for HPLC and RRLC The Agilent 126 Infinity Diode Array Detector (DAD) features
More informationFlexar FX-20 LC Pump: Ultimate Performance and Flexibility for UHPLC and HPLC
P R O D U C T N O T E Liquid Chromatography Key Features Improved productivity compatible with all UHPLC columns, the Flexar FX-20 Pump can operate at pressures as high as 18,000 psi, providing throughput
More informationMinisart Syringe Filters Removal of Particles and Microorganisms from Liquids and Gases
58 Filtration Devices Minisart Syringe Filters Minisart Syringe Filters Removal of Particles and Microorganisms from Liquids and Gases Sample Preparation HPLC UHPLC Analytics Elimination of particles from
More informationFlexar FX-20 LC Pump: Ultimate Performance and Flexibility for UHPLC and HPLC
P R O D U C T N O T E Liquid Chromatography Key Features Improved productivity compatible with all UHPLC columns, the Flexar FX-20 Pump can operate at pressures as high as 18,000 psi, providing throughput
More informationFlexible Reliable Reproducible Secure Expandable Efficient
Flexible Reliable Reproducible Secure Expandable Efficient Challenges for modern Flash columns and systems: Maximum safety during use under pressure Increased column life time High separation efficiency
More informationCHROMABOND Flash cartridges
Flash chromatography outperforming the standard CHROMABOND Flash cartridges from the silica experts www.mn-net.com MN products for Flash chromatography Contents CHROMABOND Flash solutions separations from
More informationAgilent Max-Light Cartridge Cell Information for G4212A/B DAD and G7117A/B DAD
Agilent Max-Light Cartridge Cell Information for G4212A/B DAD and G7117A/B DAD Information about the Max-Light Cartridge Cells 2 Specifications 2 Description of the dispersion volume V(σ) 2 Recommendations
More informationAgilent 1290 Infinity with ISET
Agilent 1290 Infinity with ISET User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2011 No part of this manual may be reproduced in any form or by any means (including electronic storage
More informationVertiSep TM UPS. HPLC Columns. VertiSep TM UPS HPLC Columns
Ultra performance silica with excellent stability, efficiency and column-to-column reproducibility Ultra-high surface area offer ultra high resolution for gradient elution of difficulty separation compounds
More informationMICRO GC FUSION Micro GC Fusion 3/17/2014 1
MICRO GC FUSION 1 Micro GC Fusion The Next Generation Micro GC 2 Builds on an Innovative Tradition 3000 Micro GC Micro GC Fusion MTI Micro GC 3 Micro GC Fusion Feature Highlight New Chassis Design Aesthetic,
More informationAccessories for
Accessories for 29401400 Below, the accessories are grouped into Scope of delivery and Optional accessories. Please keep this printout at hand for ordering replacement material. These lists may be subject
More informationREACH FOR MORE CHOICES IN LC ANALYSIS. FLEXAR LC Systems HPLC and UHPLC Flexar LC / Flexar FX-20
REACH FOR MORE CHOICES IN LC ANALYSIS FLEXAR LC Systems HPLC and UHPLC Flexar LC / Flexar FX-20 LC SOLUTIONS FOR ALL YOUR APPLICATIONS 2 CHOOSE EXACTLY THE SYSTEM YOU NEED Whether you need conventional
More informationQuick Setup Instructions for the Knauer HPLC-System. Quick Setup Instructions for the Knauer HPLC-System For windows XP (using CHANCE vers. 2.
For windows XP (using CHANCE vers. 2.0) Compiled by P. Madl Vers. 1.0 June 2011 1 / 9 1. Hardware Setup: Result 1.1. Attach RS 232 interface cable (designated as PC) to COM-port-1 of the laptop. 1.2. connect
More informationWaters 600E Multisolvent Delivery System Quick Start Guide
Waters 600E Multisolvent Delivery System Quick Start Guide 34 Maple Street Milford, MA 01757 WAT174-04TP, Revision 3 NOTICE The information in this document is subject to change without notice and should
More informationAutomated Fraction Re-Analysis Does it really make sense?
Automated Fraction Re-Analysis Does it really make sense? Presented by: Udo Huber 1995 PHD in organic chemistry from the University Karlsruhe/Germany 1996-97 Postdoctoral fellow at the University of Hawai
More informationHuqun Liu, Varian Inc., Lake Forest CA
Rapid development of an LC method for separating high molecular weight degradants from a biopharmaceutical product using an automated Design of Experiments (DOE) approach. Introduction Huqun Liu, Varian
More informationAgilent 1290 Infinity with ISET
Agilent 1290 Infinity with ISET User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2012, 2013 No part of this manual may be reproduced in any form or by any means (including electronic
More informationEASY-nLC Virtual Instrument for Xcalibur 2.1.x Quick Reference Guide
EASY-nLC Virtual Instrument for Xcalibur 2.1.x Quick Reference Guide This guide describes how to install, configure, and use the Thermo EASY-nLC Virtual Instrument (VI) software with the Thermo Xcalibur
More informationStandard: 2 x 500 ml and 2 x 250 ml (safety) bottles with shut-off valve and 2 µm in-line filter. Built-in 4 channel He degasser.
The UltiMate Solvent Organizer 3.9 Specifications 3.9.1 Solvent Organizer Reservoirs Solvent Degassing Standard: 2 x 500 ml and 2 x 250 ml (safety) bottles with shut-off valve and 2 µm in-line filter.
More informationHICHROM. Chromatography Columns and Supplies. HPLC Columns & Materials Partisil & Partisphere. Catalogue 8. Hichrom Limited
HI Chromatography Columns and Supplies & Materials & Partisphere Catalogue 8 Hichrom Limited 1 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)118 930 3660 Fax: +44 (0)118
More informationFlash Chromatography. Sorbtech Purity Flash Cartridges. EZ Flash Cartridges. EZ Flash Systems. Flash Chrom.
Flash Chromatography Flash Chromatography includes a variety of plastic (polypropylene) columns and the associated equipment to perform this technique. Sorbtech Purity Flash Cartridges EZ Flash Cartridges
More informationcolumns IonSwift MAX-100 Anion-Exchange Column
columns IonSwift MAX- Anion-Exchange Column The IonSwift MAX- is a high-capacity anion-exchange column with selectivity similar to the IonPac AS-HC column. IonSwift is a new generation of separation media,
More informationChromQuest 5.0 Quick Reference Guide
ChromQuest 5.0 Quick Reference Guide This guide contains an overview of the ChromQuest chromatography data system, with topics organized by workflow. For more information, refer to the ChromQuest User
More informationSepacore X10 / X50 system Technical data sheet
Sepacore X10 / X50 system Technical data sheet Sepacore X10 and X50 flash chromatography systems address most requirements for the purification of organic compounds. Whether a crude synthesis mixture or
More informationRelease Note for Agilent LC and CE Drivers Revision A.02.17
Release Note for Agilent LC and CE Drivers Revision A.02.17 Introduction This release note provides important information for the release of Agilent LC and CE drivers A.02.17. The Agilent LC and CE Driver
More informationOperating Manual. High Performance Liquid Chromatograph. Scientific Equipment Center, Prince Of Songkla University
Operating Manual High Performance Liquid Chromatograph Agilent 1100 ; VWD, DAD, FLD and RID Scientific Equipment Center, Prince Of Songkla University Operating Manual High Performance Liquid Chromatograph
More informationAgilent 1290 Infinity 2D-LC Solution
Agilent 1290 Infinity 2D-LC Solution A new flexible and userfriendly 2D-LC solution for the most complex samples Michael Frank Marketing Manager Analytical HPLC LPSD, Waldbronn, Germany April, 13 th 2012
More informationMC Prochloraz, [phenyl- 14 C]- Lot A JH
Prochloraz, [phenyl- 14 C]- Lot 48-12-492-A-29131-JH A) All chromatograms were run using the HPLC method described on the Product Data Sheet. Concentrations and volumes: Standard solution concentration
More informationHarris: Quantitative Chemical Analysis, Eight Edition CHAPTER 05: QUALITY ASSURANCE AND CALIBRATION METHODS
Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 05: QUALITY ASSURANCE AND CALIBRATION METHODS 5-0. International Measurement Evaluation Program Sample: Pb in river water (blind sample) :
More informationeprep Sample Preparation Workstation
eprep Sample Preparation Workstation Robotic Sample Preparation for the Chromatography Laboratory Easy, precise and affordable workflow automation Area (mau*min) Highly Flexible and Adaptable The eprep
More informationANALYTICAL NovoGROM COLUMNS 3.0, 4.0, and 4.6 mm i.d.
ANALYTICAL NovoGROM COLUMNS 3.0, 4.0, and 4.6 mm i.d. The analytical NovoGROM HPLC column system is many-fold proven. These columns can be connected to any HPLC system either conventionally via 1/16" capillary,
More informationRelease Note for Agilent LC and CE drivers Revision A.02.14
Release Note for Agilent LC and CE drivers Revision A.02.14 Introduction This release note provides important information for the release of Agilent LC and CE drivers A.02.14. The 1260 Infinity II LC is
More informationChromatography Software Training Materials. Contents
Chromatography Software Training Materials This document contains information on how to build a method, start the instrument to acquire data, and then process the data using the Galaxie Program. You will
More informationEquipment Overview: Safety:
PerkinElmer Series 200 HPLC: Operating Procedure 12/2/11 R.C Equipment Overview: This document outlines the basic procedure for using the Sedex light scattering detector and the PE series 200 HPLC system
More informationSIMPLIFY. QUANTIFY. The Flexar SQ 300 MS. Spare Probe Assemblies / Dielectric Capillary. Calibration Solutions. Test Kits.
Flexar SQ 300 MS VERIFY. QUANTIFY. SIMPLIFY. The Flexar SQ 300 MS Ideal for a variety of analyses, this single quadrupole detector brings the unsurpassed sample insight of mass spectrometry to liquid chromatography
More information[ Oasis Sample Extraction Products ] SENSITIVITY IN ITS PUREST FORM
[ Oasis Sample Extraction Products ] SENSITIVITY IN ITS PUREST FORM 1 SENSITIVITY in ITS PUREST FORM Combining revolutionary sorbents with innovative hardware, Oasis products are the preeminent choice
More informationChromatography Data System
Chromatography Data System Single Platform - Simply Powerful CompassCDS is SCION Instruments universal Chromatography Data System designed for instrument control, data acquisition, processing and reporting.
More informationTrends in HPLC column technology and their application
Trends in HPLC column technology and their application About long Columns and small Particles S. Lamotte, GMC/C HPLC 0 Amsterdam 6 th -0 th June 0 Outline sub µm particles in fast HPLC: A critical view!
More informationSEMI-PREPERATIVE- and PREPARATIVE NovoGROM HPLC-Columns to 10.0 cm i.d. -
SEMI-PREPERATIVE- and PREPARATIVE NovoGROM HPLC-Columns - 0.8 to 10.0 cm i.d. - Semi-preparative- and preparative NovoGROM columns in various dimensions, made of stainless steel or glass are available
More informationDESCRIPTION. DataApex Clarity 32bit multi instrument chromatography station for Windows
wwwdataapexcom e-mail: clarity@dataapexcom DESCRIPTION DataApex Clarity 32bit multi instrument chromatography station for Windows Multi-detector instruments Easy to install and easy to use Graphical user
More informationAutomating HPLC Analytical Methods Development
Automating HPLC Analytical Methods Development By Graham Shelver, Varian Inc, Walnut Creek, CA and Richard Verseput, S-Matrix Corp, Eureka, CA Abstract There are many different ways that chromatographer
More informationHPLC Basics, Equipment, and Troubleshooting
HPLC Basics, Equipment, and Troubleshooting HPLC Basics, Equipment, and Troubleshooting explains chromatography in practical terms from the ground up COURSE HANDOUT: [SECTION 14] Troubleshooting & Diagnostics
More informationAgilent Splitter Kits
Agilent Splitter Kits Installation and Configuration This technical note describes the installation and configuration of the Agilent Splitter Kits in an Agilent 1260 Infinity Series System or an Agilent
More informationACQUITY UPLC Systems with 2D Technology Capabilities Guide
ACQUITY UPLC Systems with 2D Technology Capabilities Guide Revision A Copyright Waters Corporation 2012 All rights reserved Copyright notice 2012 WATERS CORPORATION. PRINTED IN THE UNITED STATES OF AMERICA
More informationRelease Note for Agilent LC and CE Drivers Revision A.02.16
Release Note for Agilent LC and CE Drivers Revision A.02.16 Introduction This release note provides important information for the release of Agilent LC and CE drivers A.02.16. The Agilent LC and CE Driver
More informationSilicon Planar PIN Photodiode PD70-01C/TR10
Features High sensitivity Low capacitance Short switching time Wide temperature range Small package Pb free The product itself will remain within RoHS compliant version. Descriptions The is high sensitivity,
More informationFusion AE LC Method Validation Module. S-Matrix Corporation 1594 Myrtle Avenue Eureka, CA USA Phone: URL:
Fusion AE LC Method Validation Module S-Matrix Corporation 1594 Myrtle Avenue Eureka, CA 95501 USA Phone: 707-441-0404 URL: www.smatrix.com Regulatory Statements and Expectations ICH Q2A The objective
More informationNew features and Workflow Enhancements Empower 3 Software
New features and Workflow Enhancements Empower 3 Software Mogens Hallas Nordic User Training 2011 Långvik, September 6th to 9th, 2011 2011 Waters Corporation 1 Empower 3 Architecture and operating systems
More informationSepacoreControl Software data sheet
SepacoreControl Software data sheet The software is able to control the Sepacore flash X and X5 chromatography system. Designed and developed with and for laboratories, the software is intuitive, easy
More informationAgilent G6855AA MassHunter Personal
Agilent G6855AA MassHunter Personal Forensic Toxicology Database Kit Quick Start Guide What is the MassHunter Personal Forensic Toxicology Database Kit? 1 Kit Content 2 Where to find more information 4
More informationAgilent G6854AA MassHunter Personal Pesticide Database Kit Quick Start Guide
Agilent G6854AA MassHunter Personal Pesticide Database Kit Quick Start Guide What is the MassHunter Personal Pesticide Database Kit? 1 Kit Content 2 Where to find more information 3 Before You Begin 4
More informationPerkinElmer Series 200 HPLC: Operating Procedure
PerkinElmer Series 200 HPLC: Operating Procedure Chem Eng 5503 Version 1.01 Last Update 8/9/07 This document outlines the basic operating procedure for the PE series 200 HPLC, UV/Vis and SEDEX Light Scattering
More informationParticle Methods in Abaqus: DEM vs. SPH
Particle Methods in Abaqus: DEM vs. SPH 2017 About this Course Course objectives In this course you will: Learn about the SPH technique for modeling violent free-surface fluid flow (such as wave impact)
More informationNexera-i Prominence-i
C196-E091 LC Systems Nexera-i Prominence-i -Series Plus intuitive Achieving Easier Operation innovative Advanced Interactive Design intelligent Smart Features Increase Work Efficiency Shimadzu's integrated
More informationS800 Spectrawave Visible Diode Array Spectrophotometer
6 SCANNING VISIBLE INSTRUMENT FOR EDUCATION OPTIMISED FOR THE TEACHING LABORATORY S800 Spectrawave Visible Diode Array Spectrophotometer ABSORBANCE, % TRANSMISSION, CONCENTRATION AND KINETICS LARGE, EASY
More informationAgilent GC/MSD Instructions
Agilent GC/MSD Instructions GC/MS SAMPLE PREPARATION: Sample Components to Avoid Completely: The following should never be injected: metals, strong acids or bases, salts, oligomeric and polymeric material.
More informationParticle Size Distribution Analysis of Porous Powders Using the Saturn DigiSizer 5200
Application Note 38 Particle Size Distribution Analysis of Porous Powders Using the Saturn DigiSizer 5200 Porous powders find application in many industries these days. These range from catalysts to pharmaceuticals;
More informationTechnical Data Sheet mm Silicon PIN Photodiode
Technical Data Sheet 2.75 5.25mm Silicon PIN Photodiode Features Fast response times High photo sensitivity Small junction capacitance Pb free Descriptions is a high speed and sensitive PIN photodiode
More informationIntroduction to the HPLC ChemStation and Acquisition
Introduction to the HPLC ChemStation and Acquisition In This Section, We Will Discuss: How to work in the Microsoft Windows Environment The structure of the ChemStation Software. How to set up an acquisition
More informationRelease Note for Agilent LC and CE Drivers Revision A.02.15
Release Note for Agilent LC and CE Drivers Revision A.02.15 Introduction This release note provides important information for the release of Agilent LC and CE drivers A.02.15. The Agilent LC and CE Driver
More informationCliquid and MPX Driver Software. Byron Kieser Director Small Molecule System Solutions
Cliquid and MPX Driver Software Byron Kieser Director Small Molecule System Solutions Cliquid Software 3.0 Improve your bottom line by reducing costs, increasing productivity and data quality using Cliquid
More informationPreparative. Chroma- tography
Preparative Chroma- tography en Sepacore Easy to use and efficient preparative chromatography Buchi is a leading world-wide supplier of core technologies in the areas of evaporation, purification, and
More informationProtein Quantification Kit (BCA Assay)
Protein Quantification Kit (BCA Assay) Booklet Item NO. KTD3001 Product Name Protein Quantification Kit (BCA Assay) ATTENTION For laboratory research use only. Not for clinical or diagnostic use Version
More informationSOLUTIONS RECERTIFICATION CALIBRATION AND UV/VIS REFERENCE MATERIALS. Photometric and Wavelength Accuracy Reference Material Set
UV/VIS REFERENCE MATERIALS CALIBRATION AND RECERTIFICATION SOLUTIONS Photometric and Wavelength Accuracy Reference Material Set Photometric and Wavelength Accuracy Reference Material Set A set of reference
More informationMassHunter Pesticides PCD or PCDL Quick Start Guide
MassHunter Pesticides PCD or PCDL Quick Start Guide What is the MassHunter Pesticides PCD or PCDL? 3 Kit Contents 4 Where to find more information Before You Begin 7 Installation 7 Required reagents and
More informationAutomating HPLC Analytical Method Development Fusion AE Software Program White Paper
Automating HPLC Analytical Method Development Fusion AE Software Program White Paper S-Matrix Corporation 1594 Myrtle Avenue Eureka, CA 95501, USA www.smatrix.com Introduction Chromatographic analytical
More information3 Starting the chiral HPLC and logging into LC Real Time Analysis.
Edition: 1.2 Date: 7-Oct-11 Page 1 of 5 1 Responsibilities. First person responsible: Mariëlle Delville. Second person responsible: Helene I.V. Amatdjais-Groenen. 2 Definitions. Read the information on
More informationMT Thymidine, [methyl- 3 H]- Lot A THN
MT-6036 Thymidine, [methyl- 3 H]- Lot 846-160-065-A-20110826-THN A) All chromatograms were run using the HPLC method described on the Product Data Sheet. Concentrations and volumes: Standard solution concentration
More informationNEW 1200 Infinity Series Raising the Standard in HPLC
NEW 12 Infinity Series Raising the Standard in HPLC Scaling LC performance while keeping method transferability a contradiction? UHPLC for Every Lab! 122 Infinity LC 126 Infinity LC 129 Infinity LC Stefan
More informationAgilent 1200 Infinity Series High Dynamic Range Diode Array Detector Solution
Agilent 1200 Infinity Series High Dynamic Range Diode Array Detector Solution User Guide Agilent Technologies Notices Agilent Technologies, Inc. 2014 No part of this manual may be reproduced in any form
More informationThermo. EASY-nLC User Guide for LC Devices
Thermo EASY-nLC 1200 User Guide for LC Devices 60053-97273 Revision A September 2015 2015 Thermo Fisher Scientific Inc. All rights reserved. AFC, EASY-nLC, EASY-Column, EASY-Spray, Foundation, LC TriPlus,
More informationANALYTICAL SYSTEMS. L3320 Autosampler with excellent accuracy and linearity. System configuration examples
ANALYTICAL SYSTEMS Modular HPLC system can be configured according to customer needs from components as follows: PDA Detector with wavelength range 200-800 nm with scanning possibility or UV-VIS Detector
More informationAccessories for
Accessories for 29420500 Below, the accessories are grouped into Scope of delivery and Optional accessories. Please keep this printout at hand for ordering replacement material. These lists may be subject
More informationGetting low-resolution GC-MS data on the JEOL GCMate Introduction
Getting low-resolution GC-MS data on the JEOL GCMate Introduction GC-MS is a technique that combines gas phase separation and mass-based detection/characterization of analytes. It s a very sensitive method
More informationSimply Irresistible! Limited Offer April 1 June 30, 2012
New Promotion April 1 June 0, 01 Limited April 1 June 0, 01 Simply Irresistible! New s for, Multi-channel Pipettes and New Promotion April 1 June 0, 01 Simply Irresistible! New! Quality, reliability, experience,
More informationChromeleon-PA Analyzer User s Guide Dionex Corporation
Chromeleon-PA Analyzer User s Guide 2003 Dionex Corporation Document No. 031964 Revision 01 October 2003 2003 by Dionex Corporation All rights reserved worldwide. Printed in the United States of America.
More informationSupramolecular Approach to Enzyme Sensing on Paper Discs Using Lanthanide Photoluminescence
Supporting Information for Supramolecular Approach to Enzyme Sensing on Paper Discs Using Lanthanide Photoluminescence Tumpa Gorai and Uday Maitra* Department of Organic Chemistry, Indian Institute of
More informationAgilent MassHunter Workstation Software 7200 Accurate-Mass Quadrupole Time of Flight GC/MS
Agilent MassHunter Workstation Software 7200 Accurate-Mass Quadrupole Time of Flight GC/MS Familiarization Guide Before you begin 3 Prepare your system 3 Prepare the samples required for data acquisition
More informationStreamline the Chromatographic Method Validation Process using Empower 2 Method Validation Manager
Streamline the Chromatographic Method Validation Process using Empower 2 Method Validation Manager Table of Contents Introduction... 3 Optimize your chromatographic method validation workflow... 4 Efficiently
More informationUV-6 Series Double Beam UV/Vis Spectrophotometers
UV-6 Series Double Beam UV/Vis Spectrophotometers Model UV-6100 UV-6100PC UV-6300 UV-6300PC avelength Range 190-1100nm 190-1100nm Spectral Bandwidth 1.8nm 1.8nm 1.0nm 1.0nm Optical System avelength Accuracy
More informationDionex ICS-2100 Ion Chromatography System
CHROMATOGRAPHY Thermo Scientific Dionex ICS-2100 Ion Chromatography System Product Specifications The Thermo Scientific Dionex ICS-2100 system is the first Reagent-Free ion chromatography system with electrolytic
More informationFor additional information, see these documents on the Breeze 2 software DVD:
R E L E A S E N O T E S Waters Breeze 2 Read these release notes before you install and operate Breeze 2. They contain information necessary to ensure successful liquid chromatography results, including:
More informationA. About this Manual
Section A. About this Manual A. About this Manual 1. Table of Contents 1. Table of Contents... 1 2. How to Use this User Manual... 2 3. General Introduction to the PAL3 System... 3 4. PAL3 System Specifications...
More informationHITACHI LACHROM ELITE
HITACHI LACHROM ELITE Clarity Control Module ENG Code/Rev.: M133/60D Date: 7/16/2018 Phone: +420 251 013 400 DataApex Ltd. Fax: +420 251 013 401 Petrzilkova 2583/13 clarity@dataapex.com 158 00 Prague 5
More informationUniPoint System Software User s Guide
UniPoint System Software User s Guide LT2137 1998 Gilson, Inc. All rights reserved Exercise 3-Creating operations list... 4-22 Create and name operations list... 4-22 Set up steps... 4-23 Identify sample
More informationAdvancing Cancer Diagnostics Improving Lives. Leica RM2235. The Manual Rotary Microtome For Outstanding Durability, Precision, and Comfort
Advancing Cancer Diagnostics Improving Lives Leica RM2235 The Manual Rotary Microtome For Outstanding Durability, Precision, and Comfort 2 As Durable as Ever, Enhanced Precision and Comfort Like Never
More informationThe Perfect Fit for Over 40 Years
Total Solutions in Particle Characterization The Perfect Fit for Over 40 Years Microtrac s Laser Diffraction Instrumentation Delivers Tailored Solutions by Incorporating: Rugged Tri-laser design Measure
More information