1 LC s NEW! Roc LC s: The Reliable Cornerstone for Your LC Lab Conventional columns built for solid performance, exceptional value, and compact storage. Pure Chromatography

2 Roc LC s Conventional column built to be the cornerstone for your lab; pressure rated for any 00 bar system. Solid and reliable delivers the peak shape, reproducibility, ruggedness, and performance you demand. Exceptional value for routine analyses and large-volume workflows high-purity, fully porous silica backed by quality manufacturing features a variety of phases to fit most methods. Ideal for a wide range of applications from food to pharma; 5 phases cover 98% of USP methods. Newly designed minimal packaging for compact storage download serial #-specific certificates of analysis at Get more of what you want, and less of what you don t, with Roc LC columns from Restek. rder today at Roc Family of LC Phases C8 C8 Phenyl-Hexyl Cyano Silica N C H CH Si CH CH Si CH CH Si CH CH Si CH Si C8 Phenyl-Hexyl USP Phase Code L L7 L L0 L Stationary Phase Category C8, octadecylsilane C8, octylsilane phenyl cyano bare silica Ligand Type monomeric C8 monomeric C8 phenyl-hexyl cyanopropyl n/a Particle Size μm or 5 μm, spherical μm or 5 μm, spherical μm or 5 μm, spherical μm or 5 μm, spherical μm or 5 μm, spherical Pore Size 00 Å 00 Å 00 Å 00 Å 00 Å Surface Area 00 m /g 00 m /g 00 m /g 00 m /g 00 m /g Carbon Load 0% % 5% 8% n/a End-Cap yes yes yes yes n/a ph Range.5 to to to to to 8.0 Maximum Temperature 80 C 80 C 80 C 80 C 80 C Cyano

3 Roc n with These Dependable LC s Figure : ver,000 injections and Roc columns will still offer reliable performance, regardless of which dimension your method calls for % Efficiency vs # of Injections Roc 5 µm 75 bar x.6 mm 50 x.6 mm 50 x.6 mm 00 x.0 mm 50 x.0 mm 50 x.0 mm Figure : Add a Roc LC guard to further extend the life of your analytical column without impacting your retention, peak shape, or efficiency. Peaks (mg/ml). Uracil 0.0. Toluene.00. Naphthalene Biphenyl 0.06 With guard column : Roc C8 (cat.# 95565); Dimensions: 50 mm x.6 mm ID; ; Pore Size: 00 Å; Guard : Roc C8 0 mm,.0 mm ID, 5 µm (cat.# 95500); Temp.: 0 C; : Custom mix; Diluent: 50:50 Acetonitrile:water; Inj. Vol.: µl; : A: Water, B: Acetonitrile; Gradient (%B): 0.00 min (70%), Without guard column 8.00 min (70%); Flow:.0 ml/min; : 5 nm; :. k =.7 Asymmetry =.07 Plates/m = 97,5 k =.7 Asymmetry =.097 Plates/m = 9,05 LC_GN0565 Figure : From one column to the next, one lot to the next, Roc columns provide results you can trust time and time again. Reversed Phase Peaks tr (min). p-tolunitrile.7. -Butylbenzoic acid 5..,-Dimethylanisole 7.. Mefenamic acid p-xylene 9.7 Normal Phase Peaks tr (min). Benzene.5. Nitrobenzene..,,5-Trinitrobenzene 5.5.,-Dinitrotoluene 7. 5 Lot Lot 5 Lot Lot 5 Lot Lot LC_GN056 : Roc C8 (cat.# 95565); Dimensions: 50 mm x.6 mm ID; ; Pore Size: 00 Å; Temp.: 5 C; Inj. Vol.: 5 µl; : 0.05% Formic acid in water:0.05% formic acid in acetonitrile (0:60); Flow:.0 ml/min; : 0 nm; Cell Temp: 5 C; : LC_GN056 : Roc Cyano (cat.# 956E); Dimensions: 00 mm x.0 mm ID; Particle Size: µm; Pore Size: 00 Å; Temp.: 0 C; : Inj. Vol.: µl; : Water:acetonitrile (80:0); Flow: 0.6 ml/min; : 5 nm; Cell Temp.: 0 C; :. Find the entire Roc column line and order now at

4 Roc LC s from Restek Perform Better Than or Equal To s from ther Vendors Table I: Roc LC columns offer equivalent or better peak shape, retention, and resolution compared to FPP columns from other manufacturers under identical conditions (average values, n = 5). s Analyte tr Area Height USP Tailing Asymmetry (0%) k' Plate Number Resolution Ethylparaben.5,07,609 8, ,78 Roc 5.0,869,68, ,6.5 Ethylparaben.060,,6 5, ,7 Vendor A.889,860,659, , Ethylparaben.87,6,068 9, ,706 Vendor B.07,867,09 87, ,0 9.9 Ethylparaben.76,,099 5, ,6 Vendor C.580,868,7 70, ,700.9 Ethylparaben.57,99,87 57, ,78 Vendor D 5.86,77,785 8, ,95. Vendor E Ethylparaben.87,98,6, ,8 6.89,78,5 7, ,96.7 Chromatographic conditions for Table I and Figure (USP Monograph 8, ) All columns are C8 stationary phase (5 µm, 50 x.6 mm). Conditions are as follows. Mobile phase: water:acetonitrile (:); Flow rate: ml/min; Injection volume: 5 µl; : with UV detector, 80 nm; : 00 µg/ml ethinyl estradiol and 50 µg/ml ethylparaben in water:acetonitrile (:).

5 Figure : Count on Roc LC columns from Restek for outstanding chromatographic performance. Roc LC. Ethylparaben estradiol Roc C8 (cat.# 95565) Dimensions: 50 mm x.6 mm ID Pore Size: 00 Å Temp.: 0 C Inj. Vol.: 5 µl Flow (ml/min) %A , nm LC_EX058 Vendor A. Ethylparaben estradiol Vendor A C8 Dimensions: 50 mm x.6 mm ID Pore Size: 00 Å Temp.: 0 C Inj. Vol.: 5 µl Flow (ml/min) %A , nm LC_EX05 5

6 (Continued from page 5) Figure : Count on Roc LC columns from Restek for outstanding chromatographic performance. Vendor B. Ethylparaben estradiol Vendor B C8 Dimensions: 50 mm x.6 mm ID Pore Size: 0 Å Temp.: 0 C Inj. Vol.: 5 µl Flow (ml/min) %A , nm LC_EX050 Vendor C. Ethylparaben estradiol Vendor C C8 Dimensions: 50 mm x.6 mm ID Pore Size: 80 Å Temp.: 0 C Inj. Vol.: 5 µl Flow (ml/min) %A , nm LC_EX

7 (Continued from page 6) Figure : Count on Roc LC columns from Restek for outstanding chromatographic performance. Vendor D. Ethylparaben estradiol Vendor D C8 Dimensions: 50 mm x.6 mm ID Temp.: 0 C Inj. Vol.: 5 µl Flow (ml/min) %A , nm LC_EX05 Vendor E. Ethylparaben estradiol Vendor E C8 Dimensions: 50 mm x.6 mm ID Pore Size: 00 Å Temp.: 0 C Inj. Vol.: 5 µl Flow (ml/min) %A , nm LC_EX05 7

8 Get Roc Solid Performance CH Si CH Roc C8 s (USP L).0 mm.6 mm µm s 00 mm 95E mm 956E µm s 00 mm 955E mm 9556E mm 9557E H Si Silica Roc Silica s (USP L).0 mm.6 mm µm s 00 mm 950E mm 9506E µm s 00 mm 9505E mm 95056E mm 95057E C8 CH Si CH CH C8 Si C Cyano N CH Roc C8 s (USP L7).0 mm.6 mm µm s 00 mm 95E mm 956E µm s 00 mm 955E mm 9556E mm 9557E Roc Phenyl-Hexyl s (USP L).0 mm.6 mm µm s 00 mm 955E mm 9556E µm s 00 mm 9555E mm 95556E mm 95557E Roc Cyano s (USP L0).0 mm.6 mm µm s 00 mm 956E mm 9566E µm s 00 mm 9565E mm 95656E mm 95657E Roc LC Guard Cartridges Protect your Roc LC columns with minimal effect on retention, peak shape, or efficiency. Guard column cartridges require Roc guard column holder (cat.# 58). Description qty. 0 x.0 mm cat.# Roc C8 Guard Cartridge -pk Roc C8 Guard Cartridge -pk Roc Cyano Guard Cartridge -pk Roc Phenyl-Hexyl Guard Cartridge -pk Roc Silica Guard Cartridge -pk Roc LC Guard Holder Requires separate guard column cartridges (available from Restek). Description qty. cat.# Roc LC Guard Holder for 0 x.0 mm Roc Guard Cartridges ea. 58 Replacement PEEK Ferrules for Roc LC Guard Holder Description qty. cat.# Replacement PEEK Ferrules for Roc LC Guard Holder -pk. 69 Find the entire Roc column line and order now at Pure Chromatography Questions about this or any other Restek product? Contact us or your local Restek representative ( Restek patents and trademarks are the property of Restek Corporation. (See for full list.) ther trademarks in Restek literature or on its website are the property of their respective owners. Restek registered trademarks are registered in the U.S. and may also be registered in other countries. 08 Restek Corporation. All rights reserved. Printed in the U.S.A. Lit. Cat.# GNSSB-UNV

More Chemistries, More Choices For Your Toughest Separation Challenges

More Chemistries, More Choices For Your Toughest Separation Challenges Ordering Guide More Chemistries, More Choices For Your Toughest Separation Challenges Agilent InfinityLab Poroshell 120 Columns Efficiently separate the widest variety of columns Based on superficially

More information

Brownlee SPP. HPLC and UHPLC Column Solutions with Superficially Porous Particle Technology

Brownlee SPP. HPLC and UHPLC Column Solutions with Superficially Porous Particle Technology Brownlee SPP HPLC and UHPLC Column Solutions with Superficially Porous Particle Technology Say goodbye to the limitations of traditional columns. Break free from the constraints of your Liquid Chromatography

More information

HiQ sil TM HPLC Columns

HiQ sil TM HPLC Columns www.kromatek.co.uk KYA Technologies of Japan KYA Technologies Corporation, Tokyo, Japan established in 1998 to develop a range of HPLC products. The latest product HiQ sil HS is a high performance silica

More information

Achieve FASTERLC. with Onyx Monolithic Silica HPLC Columns. Featuring: New Onyx HD Columns for Increased Efficiency!

Achieve FASTERLC. with Onyx Monolithic Silica HPLC Columns. Featuring: New Onyx HD Columns for Increased Efficiency! Achieve FASTERLC with Onyx Monolithic Silica HPLC Columns Reduce run times Increase throughput Rapidly screen dirty or complex samples Featuring: New Onyx HD Columns for Increased Efficiency! Onyx Monolithic

More information

VertiSep TM GES. HPLC Columns. VertiSep TM GES HPLC Columns

VertiSep TM GES. HPLC Columns. VertiSep TM GES HPLC Columns High purity Silica offer high stability, efficiency, reproducibility Moderate pore size and surface area are perfect for general purpose High carbon loading C18 offers high degree of hydrophobicity for

More information

Guard Columns ---- HPLC Column Catalog

Guard Columns ---- HPLC Column Catalog Guard ---- Guard s selection and Use 092 Cartridge Guard E 093 Cartridge Guard Ei (Non-metal type) 094 Guard for UHPLC 096 GL Cart 098 Packed Guard, Mini Guard 099 SILFILTER TM STD C18 4 Filters, Impurity

More information

Save Money. Kromasil Columns packed by Phenomenex

Save Money. Kromasil Columns packed by Phenomenex Replace your Kromasil and Save Money Kromasil Columns packed by Phenomenex OPTION 1 Direct 2 Replacement Chrom-Clone Guaranteed* direct replacement to Kromasil Significant cost savings OPTION Performance

More information

until now. NEW ZORBAX Eclipse Plus LC Columns No LC column has ever reliably produced such symmetrical peaks for basic compounds...

until now. NEW ZORBAX Eclipse Plus LC Columns No LC column has ever reliably produced such symmetrical peaks for basic compounds... No LC column has ever reliably produced such symmetrical peaks for basic compounds... until now. NEW ZORBAX Eclipse Plus LC Columns ZORBAX Eclipse Column Portfolio I can t remember the last time I achieved

More information

Agilent s Newly Expanded ZORBAX Eclipse Plus LC Column Portfolio

Agilent s Newly Expanded ZORBAX Eclipse Plus LC Column Portfolio Agilent s Newly Expanded ZORBAX Plus LC Column Portfolio No other LC columns have ever produced such superior peaks for bases, acids, and neutrals. Enhance your productivity with new options for fast and

More information

Technical Overview. Introduction

Technical Overview. Introduction Performance characteristics of the Agilent 12 Infinity Series Variable Wavelength Detectors Faster results, improved sensitivity and absolute data security Technical Overview Introduction The Agilent 12

More information

Optimizing System Dispersion on the Agilent 1290 Infinity II LC

Optimizing System Dispersion on the Agilent 1290 Infinity II LC Optimizing System Dispersion on the Agilent 1290 Infinity II LC The Agilent Ultralow Dispersion Kit Technical Overview Authors Bettina Schuhn and Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany

More information

Agilent s Newly Expanded ZORBAX Eclipse Plus LC Column Portfolio

Agilent s Newly Expanded ZORBAX Eclipse Plus LC Column Portfolio Agilent s Newly Expanded ZORBAX Eclipse Plus LC Column Portfolio No other LC columns have ever produced such superior peaks for bases, acids, and neutrals. Enhance your productivity with new options for

More information

True Blue Performance

True Blue Performance True Blue Performance Improved Data, Fewer Liner Changes, and Less Downtime Exceptionally inert Sky inlet liners with state-of-the-art deactivation improve trace-level analysis even with wool and now come

More information

Agilent 1260 Infinity Diode Array Detector

Agilent 1260 Infinity Diode Array Detector Agilent 126 Infinity Diode Array Detector Features, Technical Details, Specifications and Ordering Details 1 x higher sensitivity for HPLC and RRLC The Agilent 126 Infinity Diode Array Detector (DAD) features

More information

Flexar FX-20 LC Pump: Ultimate Performance and Flexibility for UHPLC and HPLC

Flexar FX-20 LC Pump: Ultimate Performance and Flexibility for UHPLC and HPLC P R O D U C T N O T E Liquid Chromatography Key Features Improved productivity compatible with all UHPLC columns, the Flexar FX-20 Pump can operate at pressures as high as 18,000 psi, providing throughput

More information

Minisart Syringe Filters Removal of Particles and Microorganisms from Liquids and Gases

Minisart Syringe Filters Removal of Particles and Microorganisms from Liquids and Gases 58 Filtration Devices Minisart Syringe Filters Minisart Syringe Filters Removal of Particles and Microorganisms from Liquids and Gases Sample Preparation HPLC UHPLC Analytics Elimination of particles from

More information

Flexar FX-20 LC Pump: Ultimate Performance and Flexibility for UHPLC and HPLC

Flexar FX-20 LC Pump: Ultimate Performance and Flexibility for UHPLC and HPLC P R O D U C T N O T E Liquid Chromatography Key Features Improved productivity compatible with all UHPLC columns, the Flexar FX-20 Pump can operate at pressures as high as 18,000 psi, providing throughput

More information

Flexible Reliable Reproducible Secure Expandable Efficient

Flexible Reliable Reproducible Secure Expandable Efficient Flexible Reliable Reproducible Secure Expandable Efficient Challenges for modern Flash columns and systems: Maximum safety during use under pressure Increased column life time High separation efficiency

More information

CHROMABOND Flash cartridges

CHROMABOND Flash cartridges Flash chromatography outperforming the standard CHROMABOND Flash cartridges from the silica experts www.mn-net.com MN products for Flash chromatography Contents CHROMABOND Flash solutions separations from

More information

Agilent Max-Light Cartridge Cell Information for G4212A/B DAD and G7117A/B DAD

Agilent Max-Light Cartridge Cell Information for G4212A/B DAD and G7117A/B DAD Agilent Max-Light Cartridge Cell Information for G4212A/B DAD and G7117A/B DAD Information about the Max-Light Cartridge Cells 2 Specifications 2 Description of the dispersion volume V(σ) 2 Recommendations

More information

Agilent 1290 Infinity with ISET

Agilent 1290 Infinity with ISET Agilent 1290 Infinity with ISET User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2011 No part of this manual may be reproduced in any form or by any means (including electronic storage

More information

VertiSep TM UPS. HPLC Columns. VertiSep TM UPS HPLC Columns

VertiSep TM UPS. HPLC Columns. VertiSep TM UPS HPLC Columns Ultra performance silica with excellent stability, efficiency and column-to-column reproducibility Ultra-high surface area offer ultra high resolution for gradient elution of difficulty separation compounds

More information

MICRO GC FUSION Micro GC Fusion 3/17/2014 1

MICRO GC FUSION Micro GC Fusion 3/17/2014 1 MICRO GC FUSION 1 Micro GC Fusion The Next Generation Micro GC 2 Builds on an Innovative Tradition 3000 Micro GC Micro GC Fusion MTI Micro GC 3 Micro GC Fusion Feature Highlight New Chassis Design Aesthetic,

More information

Accessories for

Accessories for Accessories for 29401400 Below, the accessories are grouped into Scope of delivery and Optional accessories. Please keep this printout at hand for ordering replacement material. These lists may be subject

More information

REACH FOR MORE CHOICES IN LC ANALYSIS. FLEXAR LC Systems HPLC and UHPLC Flexar LC / Flexar FX-20

REACH FOR MORE CHOICES IN LC ANALYSIS. FLEXAR LC Systems HPLC and UHPLC Flexar LC / Flexar FX-20 REACH FOR MORE CHOICES IN LC ANALYSIS FLEXAR LC Systems HPLC and UHPLC Flexar LC / Flexar FX-20 LC SOLUTIONS FOR ALL YOUR APPLICATIONS 2 CHOOSE EXACTLY THE SYSTEM YOU NEED Whether you need conventional

More information

Quick Setup Instructions for the Knauer HPLC-System. Quick Setup Instructions for the Knauer HPLC-System For windows XP (using CHANCE vers. 2.

Quick Setup Instructions for the Knauer HPLC-System. Quick Setup Instructions for the Knauer HPLC-System For windows XP (using CHANCE vers. 2. For windows XP (using CHANCE vers. 2.0) Compiled by P. Madl Vers. 1.0 June 2011 1 / 9 1. Hardware Setup: Result 1.1. Attach RS 232 interface cable (designated as PC) to COM-port-1 of the laptop. 1.2. connect

More information

Waters 600E Multisolvent Delivery System Quick Start Guide

Waters 600E Multisolvent Delivery System Quick Start Guide Waters 600E Multisolvent Delivery System Quick Start Guide 34 Maple Street Milford, MA 01757 WAT174-04TP, Revision 3 NOTICE The information in this document is subject to change without notice and should

More information

Automated Fraction Re-Analysis Does it really make sense?

Automated Fraction Re-Analysis Does it really make sense? Automated Fraction Re-Analysis Does it really make sense? Presented by: Udo Huber 1995 PHD in organic chemistry from the University Karlsruhe/Germany 1996-97 Postdoctoral fellow at the University of Hawai

More information

Huqun Liu, Varian Inc., Lake Forest CA

Huqun Liu, Varian Inc., Lake Forest CA Rapid development of an LC method for separating high molecular weight degradants from a biopharmaceutical product using an automated Design of Experiments (DOE) approach. Introduction Huqun Liu, Varian

More information

Agilent 1290 Infinity with ISET

Agilent 1290 Infinity with ISET Agilent 1290 Infinity with ISET User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2012, 2013 No part of this manual may be reproduced in any form or by any means (including electronic

More information

EASY-nLC Virtual Instrument for Xcalibur 2.1.x Quick Reference Guide

EASY-nLC Virtual Instrument for Xcalibur 2.1.x Quick Reference Guide EASY-nLC Virtual Instrument for Xcalibur 2.1.x Quick Reference Guide This guide describes how to install, configure, and use the Thermo EASY-nLC Virtual Instrument (VI) software with the Thermo Xcalibur

More information

Standard: 2 x 500 ml and 2 x 250 ml (safety) bottles with shut-off valve and 2 µm in-line filter. Built-in 4 channel He degasser.

Standard: 2 x 500 ml and 2 x 250 ml (safety) bottles with shut-off valve and 2 µm in-line filter. Built-in 4 channel He degasser. The UltiMate Solvent Organizer 3.9 Specifications 3.9.1 Solvent Organizer Reservoirs Solvent Degassing Standard: 2 x 500 ml and 2 x 250 ml (safety) bottles with shut-off valve and 2 µm in-line filter.

More information

HICHROM. Chromatography Columns and Supplies. HPLC Columns & Materials Partisil & Partisphere. Catalogue 8. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. HPLC Columns & Materials Partisil & Partisphere. Catalogue 8. Hichrom Limited HI Chromatography Columns and Supplies & Materials & Partisphere Catalogue 8 Hichrom Limited 1 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)118 930 3660 Fax: +44 (0)118

More information

Flash Chromatography. Sorbtech Purity Flash Cartridges. EZ Flash Cartridges. EZ Flash Systems. Flash Chrom.

Flash Chromatography. Sorbtech Purity Flash Cartridges. EZ Flash Cartridges. EZ Flash Systems. Flash Chrom. Flash Chromatography Flash Chromatography includes a variety of plastic (polypropylene) columns and the associated equipment to perform this technique. Sorbtech Purity Flash Cartridges EZ Flash Cartridges

More information

columns IonSwift MAX-100 Anion-Exchange Column

columns IonSwift MAX-100 Anion-Exchange Column columns IonSwift MAX- Anion-Exchange Column The IonSwift MAX- is a high-capacity anion-exchange column with selectivity similar to the IonPac AS-HC column. IonSwift is a new generation of separation media,

More information

ChromQuest 5.0 Quick Reference Guide

ChromQuest 5.0 Quick Reference Guide ChromQuest 5.0 Quick Reference Guide This guide contains an overview of the ChromQuest chromatography data system, with topics organized by workflow. For more information, refer to the ChromQuest User

More information

Sepacore X10 / X50 system Technical data sheet

Sepacore X10 / X50 system Technical data sheet Sepacore X10 / X50 system Technical data sheet Sepacore X10 and X50 flash chromatography systems address most requirements for the purification of organic compounds. Whether a crude synthesis mixture or

More information

Release Note for Agilent LC and CE Drivers Revision A.02.17

Release Note for Agilent LC and CE Drivers Revision A.02.17 Release Note for Agilent LC and CE Drivers Revision A.02.17 Introduction This release note provides important information for the release of Agilent LC and CE drivers A.02.17. The Agilent LC and CE Driver

More information

Operating Manual. High Performance Liquid Chromatograph. Scientific Equipment Center, Prince Of Songkla University

Operating Manual. High Performance Liquid Chromatograph. Scientific Equipment Center, Prince Of Songkla University Operating Manual High Performance Liquid Chromatograph Agilent 1100 ; VWD, DAD, FLD and RID Scientific Equipment Center, Prince Of Songkla University Operating Manual High Performance Liquid Chromatograph

More information

Agilent 1290 Infinity 2D-LC Solution

Agilent 1290 Infinity 2D-LC Solution Agilent 1290 Infinity 2D-LC Solution A new flexible and userfriendly 2D-LC solution for the most complex samples Michael Frank Marketing Manager Analytical HPLC LPSD, Waldbronn, Germany April, 13 th 2012

More information

MC Prochloraz, [phenyl- 14 C]- Lot A JH

MC Prochloraz, [phenyl- 14 C]- Lot A JH Prochloraz, [phenyl- 14 C]- Lot 48-12-492-A-29131-JH A) All chromatograms were run using the HPLC method described on the Product Data Sheet. Concentrations and volumes: Standard solution concentration

More information

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 05: QUALITY ASSURANCE AND CALIBRATION METHODS

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 05: QUALITY ASSURANCE AND CALIBRATION METHODS Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 05: QUALITY ASSURANCE AND CALIBRATION METHODS 5-0. International Measurement Evaluation Program Sample: Pb in river water (blind sample) :

More information

eprep Sample Preparation Workstation

eprep Sample Preparation Workstation eprep Sample Preparation Workstation Robotic Sample Preparation for the Chromatography Laboratory Easy, precise and affordable workflow automation Area (mau*min) Highly Flexible and Adaptable The eprep

More information

ANALYTICAL NovoGROM COLUMNS 3.0, 4.0, and 4.6 mm i.d.

ANALYTICAL NovoGROM COLUMNS 3.0, 4.0, and 4.6 mm i.d. ANALYTICAL NovoGROM COLUMNS 3.0, 4.0, and 4.6 mm i.d. The analytical NovoGROM HPLC column system is many-fold proven. These columns can be connected to any HPLC system either conventionally via 1/16" capillary,

More information

Release Note for Agilent LC and CE drivers Revision A.02.14

Release Note for Agilent LC and CE drivers Revision A.02.14 Release Note for Agilent LC and CE drivers Revision A.02.14 Introduction This release note provides important information for the release of Agilent LC and CE drivers A.02.14. The 1260 Infinity II LC is

More information

Chromatography Software Training Materials. Contents

Chromatography Software Training Materials. Contents Chromatography Software Training Materials This document contains information on how to build a method, start the instrument to acquire data, and then process the data using the Galaxie Program. You will

More information

Equipment Overview: Safety:

Equipment Overview: Safety: PerkinElmer Series 200 HPLC: Operating Procedure 12/2/11 R.C Equipment Overview: This document outlines the basic procedure for using the Sedex light scattering detector and the PE series 200 HPLC system

More information

SIMPLIFY. QUANTIFY. The Flexar SQ 300 MS. Spare Probe Assemblies / Dielectric Capillary. Calibration Solutions. Test Kits.

SIMPLIFY. QUANTIFY. The Flexar SQ 300 MS. Spare Probe Assemblies / Dielectric Capillary. Calibration Solutions. Test Kits. Flexar SQ 300 MS VERIFY. QUANTIFY. SIMPLIFY. The Flexar SQ 300 MS Ideal for a variety of analyses, this single quadrupole detector brings the unsurpassed sample insight of mass spectrometry to liquid chromatography

More information

[ Oasis Sample Extraction Products ] SENSITIVITY IN ITS PUREST FORM

[ Oasis Sample Extraction Products ] SENSITIVITY IN ITS PUREST FORM [ Oasis Sample Extraction Products ] SENSITIVITY IN ITS PUREST FORM 1 SENSITIVITY in ITS PUREST FORM Combining revolutionary sorbents with innovative hardware, Oasis products are the preeminent choice

More information

Chromatography Data System

Chromatography Data System Chromatography Data System Single Platform - Simply Powerful CompassCDS is SCION Instruments universal Chromatography Data System designed for instrument control, data acquisition, processing and reporting.

More information

Trends in HPLC column technology and their application

Trends in HPLC column technology and their application Trends in HPLC column technology and their application About long Columns and small Particles S. Lamotte, GMC/C HPLC 0 Amsterdam 6 th -0 th June 0 Outline sub µm particles in fast HPLC: A critical view!

More information

SEMI-PREPERATIVE- and PREPARATIVE NovoGROM HPLC-Columns to 10.0 cm i.d. -

SEMI-PREPERATIVE- and PREPARATIVE NovoGROM HPLC-Columns to 10.0 cm i.d. - SEMI-PREPERATIVE- and PREPARATIVE NovoGROM HPLC-Columns - 0.8 to 10.0 cm i.d. - Semi-preparative- and preparative NovoGROM columns in various dimensions, made of stainless steel or glass are available

More information

DESCRIPTION. DataApex Clarity 32bit multi instrument chromatography station for Windows

DESCRIPTION. DataApex Clarity 32bit multi instrument chromatography station for Windows wwwdataapexcom e-mail: clarity@dataapexcom DESCRIPTION DataApex Clarity 32bit multi instrument chromatography station for Windows Multi-detector instruments Easy to install and easy to use Graphical user

More information

Automating HPLC Analytical Methods Development

Automating HPLC Analytical Methods Development Automating HPLC Analytical Methods Development By Graham Shelver, Varian Inc, Walnut Creek, CA and Richard Verseput, S-Matrix Corp, Eureka, CA Abstract There are many different ways that chromatographer

More information

HPLC Basics, Equipment, and Troubleshooting

HPLC Basics, Equipment, and Troubleshooting HPLC Basics, Equipment, and Troubleshooting HPLC Basics, Equipment, and Troubleshooting explains chromatography in practical terms from the ground up COURSE HANDOUT: [SECTION 14] Troubleshooting & Diagnostics

More information

Agilent Splitter Kits

Agilent Splitter Kits Agilent Splitter Kits Installation and Configuration This technical note describes the installation and configuration of the Agilent Splitter Kits in an Agilent 1260 Infinity Series System or an Agilent

More information

ACQUITY UPLC Systems with 2D Technology Capabilities Guide

ACQUITY UPLC Systems with 2D Technology Capabilities Guide ACQUITY UPLC Systems with 2D Technology Capabilities Guide Revision A Copyright Waters Corporation 2012 All rights reserved Copyright notice 2012 WATERS CORPORATION. PRINTED IN THE UNITED STATES OF AMERICA

More information

Release Note for Agilent LC and CE Drivers Revision A.02.16

Release Note for Agilent LC and CE Drivers Revision A.02.16 Release Note for Agilent LC and CE Drivers Revision A.02.16 Introduction This release note provides important information for the release of Agilent LC and CE drivers A.02.16. The Agilent LC and CE Driver

More information

Silicon Planar PIN Photodiode PD70-01C/TR10

Silicon Planar PIN Photodiode PD70-01C/TR10 Features High sensitivity Low capacitance Short switching time Wide temperature range Small package Pb free The product itself will remain within RoHS compliant version. Descriptions The is high sensitivity,

More information

Fusion AE LC Method Validation Module. S-Matrix Corporation 1594 Myrtle Avenue Eureka, CA USA Phone: URL:

Fusion AE LC Method Validation Module. S-Matrix Corporation 1594 Myrtle Avenue Eureka, CA USA Phone: URL: Fusion AE LC Method Validation Module S-Matrix Corporation 1594 Myrtle Avenue Eureka, CA 95501 USA Phone: 707-441-0404 URL: www.smatrix.com Regulatory Statements and Expectations ICH Q2A The objective

More information

New features and Workflow Enhancements Empower 3 Software

New features and Workflow Enhancements Empower 3 Software New features and Workflow Enhancements Empower 3 Software Mogens Hallas Nordic User Training 2011 Långvik, September 6th to 9th, 2011 2011 Waters Corporation 1 Empower 3 Architecture and operating systems

More information

SepacoreControl Software data sheet

SepacoreControl Software data sheet SepacoreControl Software data sheet The software is able to control the Sepacore flash X and X5 chromatography system. Designed and developed with and for laboratories, the software is intuitive, easy

More information

Agilent G6855AA MassHunter Personal

Agilent G6855AA MassHunter Personal Agilent G6855AA MassHunter Personal Forensic Toxicology Database Kit Quick Start Guide What is the MassHunter Personal Forensic Toxicology Database Kit? 1 Kit Content 2 Where to find more information 4

More information

Agilent G6854AA MassHunter Personal Pesticide Database Kit Quick Start Guide

Agilent G6854AA MassHunter Personal Pesticide Database Kit Quick Start Guide Agilent G6854AA MassHunter Personal Pesticide Database Kit Quick Start Guide What is the MassHunter Personal Pesticide Database Kit? 1 Kit Content 2 Where to find more information 3 Before You Begin 4

More information

PerkinElmer Series 200 HPLC: Operating Procedure

PerkinElmer Series 200 HPLC: Operating Procedure PerkinElmer Series 200 HPLC: Operating Procedure Chem Eng 5503 Version 1.01 Last Update 8/9/07 This document outlines the basic operating procedure for the PE series 200 HPLC, UV/Vis and SEDEX Light Scattering

More information

Particle Methods in Abaqus: DEM vs. SPH

Particle Methods in Abaqus: DEM vs. SPH Particle Methods in Abaqus: DEM vs. SPH 2017 About this Course Course objectives In this course you will: Learn about the SPH technique for modeling violent free-surface fluid flow (such as wave impact)

More information

Nexera-i Prominence-i

Nexera-i Prominence-i C196-E091 LC Systems Nexera-i Prominence-i -Series Plus intuitive Achieving Easier Operation innovative Advanced Interactive Design intelligent Smart Features Increase Work Efficiency Shimadzu's integrated

More information

S800 Spectrawave Visible Diode Array Spectrophotometer

S800 Spectrawave Visible Diode Array Spectrophotometer 6 SCANNING VISIBLE INSTRUMENT FOR EDUCATION OPTIMISED FOR THE TEACHING LABORATORY S800 Spectrawave Visible Diode Array Spectrophotometer ABSORBANCE, % TRANSMISSION, CONCENTRATION AND KINETICS LARGE, EASY

More information

Agilent GC/MSD Instructions

Agilent GC/MSD Instructions Agilent GC/MSD Instructions GC/MS SAMPLE PREPARATION: Sample Components to Avoid Completely: The following should never be injected: metals, strong acids or bases, salts, oligomeric and polymeric material.

More information

Particle Size Distribution Analysis of Porous Powders Using the Saturn DigiSizer 5200

Particle Size Distribution Analysis of Porous Powders Using the Saturn DigiSizer 5200 Application Note 38 Particle Size Distribution Analysis of Porous Powders Using the Saturn DigiSizer 5200 Porous powders find application in many industries these days. These range from catalysts to pharmaceuticals;

More information

Technical Data Sheet mm Silicon PIN Photodiode

Technical Data Sheet mm Silicon PIN Photodiode Technical Data Sheet 2.75 5.25mm Silicon PIN Photodiode Features Fast response times High photo sensitivity Small junction capacitance Pb free Descriptions is a high speed and sensitive PIN photodiode

More information

Introduction to the HPLC ChemStation and Acquisition

Introduction to the HPLC ChemStation and Acquisition Introduction to the HPLC ChemStation and Acquisition In This Section, We Will Discuss: How to work in the Microsoft Windows Environment The structure of the ChemStation Software. How to set up an acquisition

More information

Release Note for Agilent LC and CE Drivers Revision A.02.15

Release Note for Agilent LC and CE Drivers Revision A.02.15 Release Note for Agilent LC and CE Drivers Revision A.02.15 Introduction This release note provides important information for the release of Agilent LC and CE drivers A.02.15. The Agilent LC and CE Driver

More information

Cliquid and MPX Driver Software. Byron Kieser Director Small Molecule System Solutions

Cliquid and MPX Driver Software. Byron Kieser Director Small Molecule System Solutions Cliquid and MPX Driver Software Byron Kieser Director Small Molecule System Solutions Cliquid Software 3.0 Improve your bottom line by reducing costs, increasing productivity and data quality using Cliquid

More information

Preparative. Chroma- tography

Preparative. Chroma- tography Preparative Chroma- tography en Sepacore Easy to use and efficient preparative chromatography Buchi is a leading world-wide supplier of core technologies in the areas of evaporation, purification, and

More information

Protein Quantification Kit (BCA Assay)

Protein Quantification Kit (BCA Assay) Protein Quantification Kit (BCA Assay) Booklet Item NO. KTD3001 Product Name Protein Quantification Kit (BCA Assay) ATTENTION For laboratory research use only. Not for clinical or diagnostic use Version

More information

SOLUTIONS RECERTIFICATION CALIBRATION AND UV/VIS REFERENCE MATERIALS. Photometric and Wavelength Accuracy Reference Material Set

SOLUTIONS RECERTIFICATION CALIBRATION AND UV/VIS REFERENCE MATERIALS. Photometric and Wavelength Accuracy Reference Material Set UV/VIS REFERENCE MATERIALS CALIBRATION AND RECERTIFICATION SOLUTIONS Photometric and Wavelength Accuracy Reference Material Set Photometric and Wavelength Accuracy Reference Material Set A set of reference

More information

MassHunter Pesticides PCD or PCDL Quick Start Guide

MassHunter Pesticides PCD or PCDL Quick Start Guide MassHunter Pesticides PCD or PCDL Quick Start Guide What is the MassHunter Pesticides PCD or PCDL? 3 Kit Contents 4 Where to find more information Before You Begin 7 Installation 7 Required reagents and

More information

Automating HPLC Analytical Method Development Fusion AE Software Program White Paper

Automating HPLC Analytical Method Development Fusion AE Software Program White Paper Automating HPLC Analytical Method Development Fusion AE Software Program White Paper S-Matrix Corporation 1594 Myrtle Avenue Eureka, CA 95501, USA www.smatrix.com Introduction Chromatographic analytical

More information

3 Starting the chiral HPLC and logging into LC Real Time Analysis.

3 Starting the chiral HPLC and logging into LC Real Time Analysis. Edition: 1.2 Date: 7-Oct-11 Page 1 of 5 1 Responsibilities. First person responsible: Mariëlle Delville. Second person responsible: Helene I.V. Amatdjais-Groenen. 2 Definitions. Read the information on

More information

MT Thymidine, [methyl- 3 H]- Lot A THN

MT Thymidine, [methyl- 3 H]- Lot A THN MT-6036 Thymidine, [methyl- 3 H]- Lot 846-160-065-A-20110826-THN A) All chromatograms were run using the HPLC method described on the Product Data Sheet. Concentrations and volumes: Standard solution concentration

More information

NEW 1200 Infinity Series Raising the Standard in HPLC

NEW 1200 Infinity Series Raising the Standard in HPLC NEW 12 Infinity Series Raising the Standard in HPLC Scaling LC performance while keeping method transferability a contradiction? UHPLC for Every Lab! 122 Infinity LC 126 Infinity LC 129 Infinity LC Stefan

More information

Agilent 1200 Infinity Series High Dynamic Range Diode Array Detector Solution

Agilent 1200 Infinity Series High Dynamic Range Diode Array Detector Solution Agilent 1200 Infinity Series High Dynamic Range Diode Array Detector Solution User Guide Agilent Technologies Notices Agilent Technologies, Inc. 2014 No part of this manual may be reproduced in any form

More information

Thermo. EASY-nLC User Guide for LC Devices

Thermo. EASY-nLC User Guide for LC Devices Thermo EASY-nLC 1200 User Guide for LC Devices 60053-97273 Revision A September 2015 2015 Thermo Fisher Scientific Inc. All rights reserved. AFC, EASY-nLC, EASY-Column, EASY-Spray, Foundation, LC TriPlus,

More information

ANALYTICAL SYSTEMS. L3320 Autosampler with excellent accuracy and linearity. System configuration examples

ANALYTICAL SYSTEMS. L3320 Autosampler with excellent accuracy and linearity. System configuration examples ANALYTICAL SYSTEMS Modular HPLC system can be configured according to customer needs from components as follows: PDA Detector with wavelength range 200-800 nm with scanning possibility or UV-VIS Detector

More information

Accessories for

Accessories for Accessories for 29420500 Below, the accessories are grouped into Scope of delivery and Optional accessories. Please keep this printout at hand for ordering replacement material. These lists may be subject

More information

Getting low-resolution GC-MS data on the JEOL GCMate Introduction

Getting low-resolution GC-MS data on the JEOL GCMate Introduction Getting low-resolution GC-MS data on the JEOL GCMate Introduction GC-MS is a technique that combines gas phase separation and mass-based detection/characterization of analytes. It s a very sensitive method

More information

Simply Irresistible! Limited Offer April 1 June 30, 2012

Simply Irresistible! Limited Offer April 1 June 30, 2012 New Promotion April 1 June 0, 01 Limited April 1 June 0, 01 Simply Irresistible! New s for, Multi-channel Pipettes and New Promotion April 1 June 0, 01 Simply Irresistible! New! Quality, reliability, experience,

More information

Chromeleon-PA Analyzer User s Guide Dionex Corporation

Chromeleon-PA Analyzer User s Guide Dionex Corporation Chromeleon-PA Analyzer User s Guide 2003 Dionex Corporation Document No. 031964 Revision 01 October 2003 2003 by Dionex Corporation All rights reserved worldwide. Printed in the United States of America.

More information

Supramolecular Approach to Enzyme Sensing on Paper Discs Using Lanthanide Photoluminescence

Supramolecular Approach to Enzyme Sensing on Paper Discs Using Lanthanide Photoluminescence Supporting Information for Supramolecular Approach to Enzyme Sensing on Paper Discs Using Lanthanide Photoluminescence Tumpa Gorai and Uday Maitra* Department of Organic Chemistry, Indian Institute of

More information

Agilent MassHunter Workstation Software 7200 Accurate-Mass Quadrupole Time of Flight GC/MS

Agilent MassHunter Workstation Software 7200 Accurate-Mass Quadrupole Time of Flight GC/MS Agilent MassHunter Workstation Software 7200 Accurate-Mass Quadrupole Time of Flight GC/MS Familiarization Guide Before you begin 3 Prepare your system 3 Prepare the samples required for data acquisition

More information

Streamline the Chromatographic Method Validation Process using Empower 2 Method Validation Manager

Streamline the Chromatographic Method Validation Process using Empower 2 Method Validation Manager Streamline the Chromatographic Method Validation Process using Empower 2 Method Validation Manager Table of Contents Introduction... 3 Optimize your chromatographic method validation workflow... 4 Efficiently

More information

UV-6 Series Double Beam UV/Vis Spectrophotometers

UV-6 Series Double Beam UV/Vis Spectrophotometers UV-6 Series Double Beam UV/Vis Spectrophotometers Model UV-6100 UV-6100PC UV-6300 UV-6300PC avelength Range 190-1100nm 190-1100nm Spectral Bandwidth 1.8nm 1.8nm 1.0nm 1.0nm Optical System avelength Accuracy

More information

Dionex ICS-2100 Ion Chromatography System

Dionex ICS-2100 Ion Chromatography System CHROMATOGRAPHY Thermo Scientific Dionex ICS-2100 Ion Chromatography System Product Specifications The Thermo Scientific Dionex ICS-2100 system is the first Reagent-Free ion chromatography system with electrolytic

More information

For additional information, see these documents on the Breeze 2 software DVD:

For additional information, see these documents on the Breeze 2 software DVD: R E L E A S E N O T E S Waters Breeze 2 Read these release notes before you install and operate Breeze 2. They contain information necessary to ensure successful liquid chromatography results, including:

More information

A. About this Manual

A. About this Manual Section A. About this Manual A. About this Manual 1. Table of Contents 1. Table of Contents... 1 2. How to Use this User Manual... 2 3. General Introduction to the PAL3 System... 3 4. PAL3 System Specifications...

More information

HITACHI LACHROM ELITE

HITACHI LACHROM ELITE HITACHI LACHROM ELITE Clarity Control Module ENG Code/Rev.: M133/60D Date: 7/16/2018 Phone: +420 251 013 400 DataApex Ltd. Fax: +420 251 013 401 Petrzilkova 2583/13 clarity@dataapex.com 158 00 Prague 5

More information

UniPoint System Software User s Guide

UniPoint System Software User s Guide UniPoint System Software User s Guide LT2137 1998 Gilson, Inc. All rights reserved Exercise 3-Creating operations list... 4-22 Create and name operations list... 4-22 Set up steps... 4-23 Identify sample

More information

Advancing Cancer Diagnostics Improving Lives. Leica RM2235. The Manual Rotary Microtome For Outstanding Durability, Precision, and Comfort

Advancing Cancer Diagnostics Improving Lives. Leica RM2235. The Manual Rotary Microtome For Outstanding Durability, Precision, and Comfort Advancing Cancer Diagnostics Improving Lives Leica RM2235 The Manual Rotary Microtome For Outstanding Durability, Precision, and Comfort 2 As Durable as Ever, Enhanced Precision and Comfort Like Never

More information

The Perfect Fit for Over 40 Years

The Perfect Fit for Over 40 Years Total Solutions in Particle Characterization The Perfect Fit for Over 40 Years Microtrac s Laser Diffraction Instrumentation Delivers Tailored Solutions by Incorporating: Rugged Tri-laser design Measure

More information