1 Guard ---- Guard s selection and Use 092 Cartridge Guard E 093 Cartridge Guard Ei (Non-metal type) 094 Guard for UHPLC 096 GL Cart 098 Packed Guard, Mini Guard 099 SILFILTER TM STD C18 4 Filters, Impurity Remove 5 HPLC Catalog 091
2 Guard s Selection and Use Guard columns are installed between the injector and the analytical column of a HPLC system, mainly to protect analytical columns. Guard columns are widely used as a cost effective for prolong HPLC column life. Exchangeable cartridge design and unchangeable packing design are offered. Exchangeable cartridge design contains holder and cartridge column, and the cartridge columns are disposable, easy -to-use, and you can change the guard column in seconds. Packed design is packed as same as analytical column, using as a guard column. Guard column design Description Compatible analytical columns ID Guard columns length Cartridge Guard E Page 93 First choice for Guard 1.0~1.5 mm mm Cartridge Guard Ei Page 94 Guard column with PEEK inlet and outlet 2.1~4.6 mm, 20 mm Exchangeable Cartridge design UHPLC Guard Page 96 For high speed, high efficiency separations 1.0~3.0 mm mm SILFILTER STD C18 Page 4 Almightily for various ODS columns 3.0~4.6 mm mm GL-Cart Guard Page 98 Direct-Connection and Indirect- Connection designs with economic cost 4.0, 4.6 mm 5 mm Packed Guard Page 99 Packed as same as analytical column 1.0~4.6 mm 33, 50 mm Unchangeable packed design Packed Mini Guard Page 3 Short length type of packed guard column 4.0, 4.6 mm mm Preparative Guard Page 114 Guard columns for preparative columns 6.0~0 mm 50 mm 75 mm(for 50 mm ) 0 mm (for 0 mm ) Selecting packing material When selecting the packing material for the guard columns, we recommend to choose the same with analytical columns. However, SILFILTER STD C18 is an monolithic guard column, it can fi t different kinds of ODS columns. Selecting dimensions Particle size : To not alter the chromatography of the analytical column, the packing of the guard column should be the same as the analytical column. Inner diameter : Choose a guard column with an internal diameter similar to the analytical column internal diameter. Pre-column Coupler W (PCTFE) Connectors Universal self-adjusting connector Coupler, using for when connect guard columns and analytical column. Pre-column Coupler SUS 092 HPLC Catalog
3 Cartridge Guard E Cartridge guard column E designed with an special holder and cartridge, universal selfadjusting connections, reusable by changing cartridges. Cartridges contain the same high performance packing material that are used in our GL Sciences analytical columns. Easy-to-use, convenient, and disposable guard columns can protect your more expensive analytical columns. Reversed Phase Line-up list InertSustain C18 of the Length E Guard Cartridge E Holder/ (2 Cartridge E Guard 3 μm 5 μm 3 μm 5 μm , , , , , Inertsil ODS-4 of the Length E Guard Cartridge E Holder/ (2 Cartridge E Guard 3 μm 5 μm 3 μm 5 μm , , , , , Inertsil ODS-3 of the Length E Guard Cartridge E Holder/ (2 Cartridge E Guard 3 μm 4 μm 5 μm 3 μm 4 μm 5 μm , , , , , Inertsil ODS-2 Cartridge Guard E of the Length E Guard Cartridge E Holder/ (2 Cartridge E Guard , , , , , * Other packing material of cartridge guard columns E are available, please confi rm page 5~87 of each analytical columns. HILIC Normal Phase SEC Ion Exchange Application Specifi c Guard Preparative Capillary Applications Cat. No. Index HPLC Catalog 093
4 Cartridge Guard Ei (Non-metal type) Cartridge Guard column Ei is a special design for the separation which need to avoid the metal accessible surface. It is signed with a special PEEK holder and cartridge. * Length of Cartridge Guard column Ei is mm Cartridge Guard Ei (Non-metal type) InertSustain C18 of the 1.0, , Inertsil ODS-3 of the 1.0, , Inertsil ODS-SP of the 1.0, , Inertsil ODS-EP of the 1.0, , Inertsil C8-4 of the 1.0, , Inertsil ODS-4 of the 1.0, , Inertsil ODS-2 of the 1.0, , Inertsil ODS-P of the 1.0, , InertSustain C8 of the 1.0, , Inertsil C8-3 of the 1.0, , * All Cartridge Guard column Ei designed with mm length. 094 HPLC Catalog
5 Cartridge Guard Ei (Non-metal type) InertSustain Phenyl of the 1.0, , Inertsil CN-3 of the 1.0, , Inertsil Amide of the 1.0, , InertSustain NH2 of the 1.0, , Inertsil Diol of the 1.0, , Inertsil WP300 Diol of the 1.0, , Inertsil Ph-3 of the 1.0, , Inertsil WP300 C18 of the 1.0, , Inertsil HILIC of the 1.0, , Inertsil NH2 of the 1.0, , Inertsil SIL-0A of the 1.0, , Reversed Phase HILIC Normal Phase SEC Ion Exchange Application Specifi c Guard Preparative Capillary Applications Cat. No. Index * All Cartridge Guard column Ei designed with mm length. * Other packing material of cartridge guard columns Ei are available, please contact your local distributor for more information. HPLC Catalog 095
6 Guard for UHPLC Holder for UHPLC Guard Guard InertSustain C18 Length Guide Packing Guard column for UHPLC signifi cantly extends column lifetime of your analytical column. The replacement cartridge guard column can be exchanged easily. A 1/16 inch tube is connected at the outlet of the holder for easy installation with minimized dead volume. Specifications Silica : High Purity Silica Gel : 2 μm, 3 μm Maximum Pressure : 80 MPa column : 1.0 ~ 3.0 mm Guard (2 EA) 2 μm 3 μm 2 μm 3 μm InertSustainSwift TM C18 Guard (2 EA) Length 1.9 μm 3 μm 1.9 μm 3 μm Inertsil ODS-4 Length Guard (2 EA) 2 μm 3 μm 2 μm 3 μm Inertsil ODS-3 Length Guard (2 EA) 2 μm 3 μm 2 μm 3 μm Inertsil ODS-SP Length Guard (2 EA) 3 μm 3 μm HPLC Catalog
7 Guard for UHPLC InertSustain C8 Guard (2 EA) Length 2 μm 3 μm 2 μm 3 μm Inertsil C8-4 Guard (2 EA) Length 2 μm 3 μm 2 μm 3 μm Reversed Phase HILIC Normal Phase Inertsil C8-3 Guard (2 EA) Length 2 μm 3 μm 2 μm 3 μm InertSustain Phenyl Guard (2 EA) Length 2 μm 3 μm 2 μm 3 μm SEC Ion Exchange Application Specifi c Inertsil Ph-3 Length Holder Guard (2 EA) 2 μm 3 μm 2 μm 3 μm Description Cat.No. Holder for UHPLC Guard * The tube size at the holder is 1/16 inch O.D mm 30 mm length. Installation Outlet side of the injector 1/16 inch Female (No.-32UNF) Tubing tip length is 2.4 mm. side Purchase a proper joint. Joint Very High Pressure Re-useable Fitting Description Max. Pressure QTY Cat.No. VHP MPa 1 set VHP MPa 1 set * The tube size at the holder is 1/16 inch O.D mm 30 mm length. VHP-300 VHP-320 Guard Preparative Capillary Applications Cat. No. Index HPLC Catalog 097
8 GL Cart GL Cart guard column are designed as economical type to protect your expensive analytical column. GL Cart is one dimension 5mmL 4.6mm (Compatible analytical columns ID is 4.0 mm, 4.6 mm.) GL Cart holder is reusable. InertSustain C18 Inertsil ODS-4 Packing material Particle size (μm) Cartridge guard column GL Cart EA.(5 4.6 mm ) Cat. No. GL Cart Set (5 GL Cart cartridge + 1 holder ) Cat. No Inertsil ODS Inertsil ODS Inertsil ODS-SP Inertsil ODS-P Inertsil ODS-EP InertSustain C8 Inertsil C8-4 Inertsil C8-3 InertSustain Phenyl Inertsil Ph Inertsil CN Inertsil WP300 C Inertsil WP300 C Inertsil WP300 C Inertsil Amide Inertsil HILIC InertSustain NH2 Inertsil NH2 Inertsil Diol GL Cart Inertsil SIL-0A Inertsil SIL-150A Inertsil WP300 SIL Inertsil WP300 Diol * Other packing material of GL Cart guard columns are available, please contact your local distributor for more information. 098 HPLC Catalog
9 Packed Guard, Packed Mini Guard Packed guard column and Mini guard column are designed different with cartridges type, using a high pressure to pack it as a guard column, and also can sustain analytical column s performance. Packed guard column has length 33 mm and 50 mm two types, and Mini guard column has length mm. Reversed Phase Packed Guard Packed Mini Guard Packed Guard InertSustain C18 Inertsil ODS-4 Inertsil ODS-3 Inertsil ODS-2 Inertsil ODS-SP Inertsil ODS-P Inertsil ODS-EP Packing material Length 33 mm Length 50 mm 3 μm 5 μm 3 μm 5 μm HILIC Normal Phase SEC Ion Exchange Application Specifi c Guard Preparative Capillary Applications Cat. No. Index HPLC Catalog 099
10 Packed Guard, Packed Mini Guard Packed Guard columns InertSustain C8 Inertsil C8-4 Inertsil C8-3 Inertsil C8 Inertsil C4 InertSustain Phenyl Inertsil Ph-3 Inertsil Ph Packing material Length 33 mm Length 50 mm 3 μm 5 μm 3 μm 5 μm HPLC Catalog
11 Packed Guard, Packed Mini Guard Packed Guard columns Inertsil CN-3 Inertsil WP300 C18 Inertsil WP300 C8 Inertsil WP300 C4 Inertsil Amide Inertsil HILIC InertSustain NH2 Inertsil NH2 Packing material Length 33 mm Length 50 mm 3 μm 5 μm 3 μm 5 μm Reversed Phase HILIC Normal Phase SEC Ion Exchange Application Specifi c Guard Preparative Capillary Applications Cat. No. Index HPLC Catalog 1
12 Packed Guard, Packed Mini Guard Packed Guard columns Inertsil Diol Inertsil SIL-0A Inertsil SIL-150A Inertsil WP300 SIL Inertsil WP300 Diol Packing material Length 33 mm Length 50 mm 3 μm 5 μm 3 μm 5 μm HPLC Catalog
13 Packed Guard, Packed Mini Guard Packed Mini Guard columns InertSustain C18 Inertsil ODS-4 Packing material (μm) Length Cat. No Inertsil ODS Inertsil ODS Inertsil ODS-SP Inertsil ODS-P Inertsil ODS-EP Inertsil ODS-80A InertSustain C8 Inertsil C Inertsil C Inertsil C Inertsil C InertSustain Phenyl Inertsil Ph Inertsil Ph Inertsil CN Inertsil WP300 C Inertsil WP300 C Inertsil WP300 C Inertsil Amide Inertsil HILIC InertSustain NH2 Inertsil NH2 Inertsil Diol Inertsil SIL-0A Inertsil SIL-150A Inertsil WP300 SIL Inertsil WP300 Diol Reversed Phase HILIC Normal Phase SEC Ion Exchange Application Specifi c Guard Preparative Capillary Applications Cat. No. Index HPLC Catalog 3
14 SILFILTER TM STD C18 SILFILTER STD C18 is a guard column with cartridge size 3.0 mm mm. The cartridge is packed with a monolithic silica, chemically bonded with a C18 and uniquely end-capped based on our 45 years of experience. SILFILTER STD C18 can be installed and used for all C18 columns available in the market without interfering and infl uencing the elution or separation patterns. Also, deterioration of the packing in the cartridge can be confi rmed visually. Feature Can be installed for all C18 columns available in the market. Deterioration of the packing in the cartridge can be confi rmed visually. Easy to replace the cartridges. Effectively removes particulate and strongly retained sample compounds Delivers the lowest dead-volume. Specification Base Material : High Purity Monolithic Silica End-capping : Yes Max.Operating Pressure : 35 MPa (350 Bar) ph Range : 1~7.5 Bonded Phase : Octadecyl Groups Max.Temperature : 50 C Size : 3.0 mm Compatible analytical ID : 3.0~4.6 mm No Sacrifice in Separation Efficiency The following test was conducted to confi rm the effi ciency of SILFILTER STD C18. As shown below, the effi ciency didn t decrease even for those fast eluting samples when installing SILFILTER STD C18. C18 column only RT : 3.2 min N : 18, RT : 7.7 min N : 18, With SILFILTER STD C18 RT : 3.4 min N : 18, RT : 8.0 min N : 18, Conditions : C18 (3 μm, mm ) Eluent : A) CH3CN B) H2O A/B = 65/35, v/v Flow Rate : 0.4 ml/min Col. Temp. : 40 C Detection : UV 254 nm Sample Acetaminophen Benzene Toluene Naphthalene Time(min) Time(min) Set A (with tube) Set B (without tube) Item Cat.No. SILFILTER STD C18, Set A* 1 2 Cartridges with 1 Holder and Tubes SILFILTER STD C18, Set B * 2 2 Cartridges with 1 Holder, without Tubes SILFILTER(with Tubes) Holder for A type* SILFILTER(without Tubes) Holder for B type* Replaceable Cartridge, 2 ea PEEK Tough Connector, 5 pcs * 1: Tube size is, 1/16 inch O.D mm 30 mml * 2: Tubing tip length is 2.4 mm PEEK Tough Connector 4 HPLC Catalog
15 Filters, Impurity Remove Pre- Coupler Pre-column Coupler W (PCTFE) Pre-column Coupler SUS Precolumn Coupler is an easy-to-use tool to connect guard columns and analytical columns. Pre-column Coupler has two designs, one is using PCTFE material, except common organic solvents, acidic solvent and basic solvent also can be used. And another one is stainless design, it can be used as high pressure. Specification Max. operation pressure: 14.7 MPa (PCTFE), 80 MPa (stainless) Tube O.D.: 1/16 Item Material Connection Cat.No. Pre-column Coupler W PCTFE Waters type Pre-column Coupler SUS Stainless * * Product Pre-column Coupler SUS doe not fi xed with Ferrules, therefore columns with -32UNF specifi cation all can be used. Reversed Phase HILIC Normal Phase Pre- Filter Pre-column fi lter Connect with 1/16 fitting Filter φ 0.50 Specification Fit in tube O.D. : 1/16 Screw specifi cation : -32UNF Filter pore size : 2 μm Max. operation pressure : 41.4 MPa(SUS) 34.5 MPa(PEEK) Item Jacket material P/N Qty. (pc) Cat.No. Pre-column fi lter 2 μm Stainless A Replacement pre-column fi lter 2 μm A PEEK pre-column fi lter 2 μm PEEK A Replacement PEEK pre-column fi lter 2 μm A SEC Ion Exchange Application Specifi c Pre-Clean ORG A guard column to install between the pump and injector, to remove the impurity in aqueous eluent. Protect analytical LC columns, and prolong analytical columns lifetime. Easy-to-replace. Also can be used as an in-line fi lter, semimicro columns are most appropriate for column clog. 2 types for two different fl ow rates. Pre-clean ORG Item Length Recommend fl ow rate (ml/min) Cat.No. Pre-clean ORG replacement cartridge 2ea ~20 ml/min Pre-clean ORG holder and cartridgex2ea ~20 ml/min Pre-clean ORG holder Pre-clean ORG semi replacement cartridge 2ea ~2.0 ml/min Pre-clean ORG semi holder and cartridgex2ea ~2.0 ml/min Pre-clean ORG semi holder Guard Preparative Capillary Applications Cat. No. Index HPLC Catalog 5
16 6 HPLC Catalog
HiQ sil TM HPLC Columns
www.kromatek.co.uk KYA Technologies of Japan KYA Technologies Corporation, Tokyo, Japan established in 1998 to develop a range of HPLC products. The latest product HiQ sil HS is a high performance silica
More informationBrownlee SPP. HPLC and UHPLC Column Solutions with Superficially Porous Particle Technology
Brownlee SPP HPLC and UHPLC Column Solutions with Superficially Porous Particle Technology Say goodbye to the limitations of traditional columns. Break free from the constraints of your Liquid Chromatography
More informationSEMI-PREPERATIVE- and PREPARATIVE NovoGROM HPLC-Columns to 10.0 cm i.d. -
SEMI-PREPERATIVE- and PREPARATIVE NovoGROM HPLC-Columns - 0.8 to 10.0 cm i.d. - Semi-preparative- and preparative NovoGROM columns in various dimensions, made of stainless steel or glass are available
More informationFlexible Reliable Reproducible Secure Expandable Efficient
Flexible Reliable Reproducible Secure Expandable Efficient Challenges for modern Flash columns and systems: Maximum safety during use under pressure Increased column life time High separation efficiency
More informationANALYTICAL NovoGROM COLUMNS 3.0, 4.0, and 4.6 mm i.d.
ANALYTICAL NovoGROM COLUMNS 3.0, 4.0, and 4.6 mm i.d. The analytical NovoGROM HPLC column system is many-fold proven. These columns can be connected to any HPLC system either conventionally via 1/16" capillary,
More informationNEW! Roc LC Columns: The Reliable Cornerstone for Your LC Lab
LC s NEW! Roc LC s: The Reliable Cornerstone for Your LC Lab Conventional columns built for solid performance, exceptional value, and compact storage. www.restek.com/roc Pure Chromatography www.restek.com
More informationHICHROM. Chromatography Columns and Supplies. HPLC Columns & Materials Partisil & Partisphere. Catalogue 8. Hichrom Limited
HI Chromatography Columns and Supplies & Materials & Partisphere Catalogue 8 Hichrom Limited 1 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)118 930 3660 Fax: +44 (0)118
More informationuntil now. NEW ZORBAX Eclipse Plus LC Columns No LC column has ever reliably produced such symmetrical peaks for basic compounds...
No LC column has ever reliably produced such symmetrical peaks for basic compounds... until now. NEW ZORBAX Eclipse Plus LC Columns ZORBAX Eclipse Column Portfolio I can t remember the last time I achieved
More informationCHROMABOND Flash cartridges
Flash chromatography outperforming the standard CHROMABOND Flash cartridges from the silica experts www.mn-net.com MN products for Flash chromatography Contents CHROMABOND Flash solutions separations from
More informationMore Chemistries, More Choices For Your Toughest Separation Challenges
Ordering Guide More Chemistries, More Choices For Your Toughest Separation Challenges Agilent InfinityLab Poroshell 120 Columns Efficiently separate the widest variety of columns Based on superficially
More informationACQUITY UPLC Systems with 2D Technology Capabilities Guide
ACQUITY UPLC Systems with 2D Technology Capabilities Guide Revision A Copyright Waters Corporation 2012 All rights reserved Copyright notice 2012 WATERS CORPORATION. PRINTED IN THE UNITED STATES OF AMERICA
More informationAccessories for
Accessories for 29401400 Below, the accessories are grouped into Scope of delivery and Optional accessories. Please keep this printout at hand for ordering replacement material. These lists may be subject
More informationOptimizing System Dispersion on the Agilent 1290 Infinity II LC
Optimizing System Dispersion on the Agilent 1290 Infinity II LC The Agilent Ultralow Dispersion Kit Technical Overview Authors Bettina Schuhn and Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany
More informationAchieve FASTERLC. with Onyx Monolithic Silica HPLC Columns. Featuring: New Onyx HD Columns for Increased Efficiency!
Achieve FASTERLC with Onyx Monolithic Silica HPLC Columns Reduce run times Increase throughput Rapidly screen dirty or complex samples Featuring: New Onyx HD Columns for Increased Efficiency! Onyx Monolithic
More informationMinisart Syringe Filters Removal of Particles and Microorganisms from Liquids and Gases
58 Filtration Devices Minisart Syringe Filters Minisart Syringe Filters Removal of Particles and Microorganisms from Liquids and Gases Sample Preparation HPLC UHPLC Analytics Elimination of particles from
More informationTechnical Overview. Introduction
Performance characteristics of the Agilent 12 Infinity Series Variable Wavelength Detectors Faster results, improved sensitivity and absolute data security Technical Overview Introduction The Agilent 12
More informationFlexar FX-20 LC Pump: Ultimate Performance and Flexibility for UHPLC and HPLC
P R O D U C T N O T E Liquid Chromatography Key Features Improved productivity compatible with all UHPLC columns, the Flexar FX-20 Pump can operate at pressures as high as 18,000 psi, providing throughput
More informationVertiSep TM GES. HPLC Columns. VertiSep TM GES HPLC Columns
High purity Silica offer high stability, efficiency, reproducibility Moderate pore size and surface area are perfect for general purpose High carbon loading C18 offers high degree of hydrophobicity for
More informationFlexar FX-20 LC Pump: Ultimate Performance and Flexibility for UHPLC and HPLC
P R O D U C T N O T E Liquid Chromatography Key Features Improved productivity compatible with all UHPLC columns, the Flexar FX-20 Pump can operate at pressures as high as 18,000 psi, providing throughput
More informationBio Compatibility Kit
General Information 1 Installing the 2 How to Use the 5 Important Safety and Solvent Compatibility Considerations 5 Setting the Minimum or Maximum Operating Pressure in ChemStation 7 Setting the Minimum
More informationAccessories for
Accessories for 29420500 Below, the accessories are grouped into Scope of delivery and Optional accessories. Please keep this printout at hand for ordering replacement material. These lists may be subject
More informationCHROMATOGRAPHY CHROMATOGRAPHY. A World of Expertise, in your hands
A World of Expertise, in your hands Chromaflex, Flex-Column and Disposaflex Chromatography Columns - (pages 2-7) TLC Tanks, Sprayers & Accessories (pages 8-2) Ultra-Ware HPLC Mobile Phase Handling Systems
More information2 CHROMATOGRAPHY. Specifications. t Go To TOC jacketed column shown with optional flow adapter.
CHROMATOGRAPHY Kimble offers an extensive line of glass chromatography products. CHROMAFLEX jacketed and standard columns are our highest quality line of columns and may be used in more demanding situations
More informationAgilent Max-Light Cartridge Cell Information for G4212A/B DAD and G7117A/B DAD
Agilent Max-Light Cartridge Cell Information for G4212A/B DAD and G7117A/B DAD Information about the Max-Light Cartridge Cells 2 Specifications 2 Description of the dispersion volume V(σ) 2 Recommendations
More informationFlash Chromatography. Sorbtech Purity Flash Cartridges. EZ Flash Cartridges. EZ Flash Systems. Flash Chrom.
Flash Chromatography Flash Chromatography includes a variety of plastic (polypropylene) columns and the associated equipment to perform this technique. Sorbtech Purity Flash Cartridges EZ Flash Cartridges
More informationStandard: 2 x 500 ml and 2 x 250 ml (safety) bottles with shut-off valve and 2 µm in-line filter. Built-in 4 channel He degasser.
The UltiMate Solvent Organizer 3.9 Specifications 3.9.1 Solvent Organizer Reservoirs Solvent Degassing Standard: 2 x 500 ml and 2 x 250 ml (safety) bottles with shut-off valve and 2 µm in-line filter.
More informationfor AutoRegen Regenerant Cartridge Refills
for AutoRegen Regenerant Cartridge Refills AutoRegen Cartridge Refill Document No. 032852-10 Page 1 of 7 PRODUCT MANUAL for the AutoRegen REGENERANT CARTRIDGE REFILLS ANION CARTRIDGE (P/N 039564) and CATION
More informationAgilent s Newly Expanded ZORBAX Eclipse Plus LC Column Portfolio
Agilent s Newly Expanded ZORBAX Eclipse Plus LC Column Portfolio No other LC columns have ever produced such superior peaks for bases, acids, and neutrals. Enhance your productivity with new options for
More informationAgilent s Newly Expanded ZORBAX Eclipse Plus LC Column Portfolio
Agilent s Newly Expanded ZORBAX Plus LC Column Portfolio No other LC columns have ever produced such superior peaks for bases, acids, and neutrals. Enhance your productivity with new options for fast and
More informationEducational Microfluidic Starter Kit
Educational Microfluidic Starter Kit Product datasheet Page Description 4 Benefits 5 System Specifications 5 Typical System setup 6 Parts List 7 IP License 19 MAR-000189_v.A.11 Page 1 of 20 Low Pressure
More informationcolumns IonSwift MAX-100 Anion-Exchange Column
columns IonSwift MAX- Anion-Exchange Column The IonSwift MAX- is a high-capacity anion-exchange column with selectivity similar to the IonPac AS-HC column. IonSwift is a new generation of separation media,
More informationAssembly and Maintenance
Assembly and Maintenance Assembly and Maintenance Test Pumps Pressure Test Pumps Tests all types of installations such as heating, compressed air and refrigeration systems, oil installations, fire lines
More informationModular Functional Fluid Circuit Guide
Modular Functional Fluid Circuit Guide In this guide you will find: Injector Example Injector Parts List Reactor Example Reactor Parts List Centrifuge Example Centrifuge Parts List Instructions for Making
More informationSave Money. Kromasil Columns packed by Phenomenex
Replace your Kromasil and Save Money Kromasil Columns packed by Phenomenex OPTION 1 Direct 2 Replacement Chrom-Clone Guaranteed* direct replacement to Kromasil Significant cost savings OPTION Performance
More informationAgilent Splitter Kits
Agilent Splitter Kits Installation and Configuration This technical note describes the installation and configuration of the Agilent Splitter Kits in an Agilent 1260 Infinity Series System or an Agilent
More informationCall toll-free Chromaflex, Flex-Column and Disposaflex Chromatography Columns pages 2-17
Chromaflex, Flex-Column and Disposaflex Chromatography Columns pages 2-7 TLC Tanks, Sprayers and Accessories pages 8-2 Ultra-Ware HPLC Mobile Phase Handling Systems pages 22-28 Chromatography Vials and
More informationQuickChange NX Liquid Filters
MICROCONTMINTION CONTROL QuickChange NX Liquid Filters High-performance, yield-enabling particle protection for aqueous-based chemistries QuickChange NX nondewetting filters deliver a cost-effective solution
More informationApplication Bulletin 321 e. Installation Instructions of TitrIC 7
The TitrIC 7 System is used for the fully automatic analysis of water samples using direct measurement, titration and ultrafiltration for the ion chromatography measurements. The following measured parameters
More informationAgilent SD-1 Purification Solution
Agilent SD-1 Purification Solution System User Guide SD-1 Purification Solution - System Manual Agilent Technologies Notices Agilent Technologies, Inc. 2012, 2013 No part of this manual may be reproduced
More informationROXY EC system. Installation requirements. Antec Industrieweg NV Zoeterwoude The Netherlands , Edition 4, 2012
Antec Industrieweg 12 2382 NV Zoeterwoude The Netherlands ROXY EC system Installation requirements 210.7050, Edition 4, 2012 T +31 71 5813333 F +31 71 5813334 info@myantec.com www.myantec.com Copyright
More information9 Maintenance and Repair
Agilent 1200 Infinity II Series RID User Manual 9 Maintenance and Repair Introduction to Maintenance 120 Warnings and Cautions 121 Overview of Maintenance 123 Cleaning the Module 124 Storage of the Detector
More informationInstallation Instructions of TitrIC 3
Metrohm Metrohm Application Bulletin 287 e 861 Dual Channel Advanced Compact IC with 815 USB Sample Processor Metrohm 800 Dosino 20 ml VENT HNO 3 800 Dosino 800 Dosino 50 ml VENT 10 ml VENT 815 712 3x
More informationVertiSep TM UPS. HPLC Columns. VertiSep TM UPS HPLC Columns
Ultra performance silica with excellent stability, efficiency and column-to-column reproducibility Ultra-high surface area offer ultra high resolution for gradient elution of difficulty separation compounds
More informationSupporting Information
Supporting Information Quantitative Profiling of Oxidized Phospholipids in Lipoproteins from Patients with Coronary Artery Disease by Hollow Fiber Flow Field-Flow Fractionation and Nanoflow Liquid Chromatography-Tandem
More informationDual Outlet Easy Program Automatic Tap Timer
Dual Outlet Easy Program Automatic Tap Timer Your GardenMate Dual Outlet Easy Program Automatic Tap Timer is two independent tap timers in one unit. It gives you all the convenience of set and forget garden
More informationOperating Manual. High Performance Liquid Chromatograph. Scientific Equipment Center, Prince Of Songkla University
Operating Manual High Performance Liquid Chromatograph Agilent 1100 ; VWD, DAD, FLD and RID Scientific Equipment Center, Prince Of Songkla University Operating Manual High Performance Liquid Chromatograph
More informationAgilent 1260 Infinity Diode Array Detector
Agilent 126 Infinity Diode Array Detector Features, Technical Details, Specifications and Ordering Details 1 x higher sensitivity for HPLC and RRLC The Agilent 126 Infinity Diode Array Detector (DAD) features
More informationWafer Handling Tools Vacuum Wands
Wafer Handling Tools Vacuum Wands C Series The material of the body is Nylon blended carbon fiber. The valve part is made of fluorocarbon resin and coated with Nylon blended carbon fiber by unique molding
More informationSIMPLIFY. QUANTIFY. The Flexar SQ 300 MS. Spare Probe Assemblies / Dielectric Capillary. Calibration Solutions. Test Kits.
Flexar SQ 300 MS VERIFY. QUANTIFY. SIMPLIFY. The Flexar SQ 300 MS Ideal for a variety of analyses, this single quadrupole detector brings the unsurpassed sample insight of mass spectrometry to liquid chromatography
More informationProduct Catalog. EasySampler EasySampler Unattended, Representative Sampling
Product Catalog EasySampler 1210 EasySampler Unattended, Representative Sampling Table of Contents General Introduction 3 Tools to Speed Chemical Development 4 5 EasySampler 1210 System 6 10 EasySampler
More informationSepacore X10 / X50 system Technical data sheet
Sepacore X10 / X50 system Technical data sheet Sepacore X10 and X50 flash chromatography systems address most requirements for the purification of organic compounds. Whether a crude synthesis mixture or
More informationDisposable Glassware CO R N I N G A N D P Y R E X D I S P O S A B L E G L A S SWA R E D I G I TA L ST I R R I N G H OT P L AT E S...
Disposable Glassware and Equipment CO R N I N G A N D P Y R E X D I S P O S A B L E WA R E........................... 128 D I G I TA L ST I R R I N G H OT P L AT E S............. 135 Digital Stirring Hot
More informationPreparative. Chroma- tography
Preparative Chroma- tography en Sepacore Easy to use and efficient preparative chromatography Buchi is a leading world-wide supplier of core technologies in the areas of evaporation, purification, and
More informationNEW 1200 Infinity Series Raising the Standard in HPLC
NEW 12 Infinity Series Raising the Standard in HPLC Scaling LC performance while keeping method transferability a contradiction? UHPLC for Every Lab! 122 Infinity LC 126 Infinity LC 129 Infinity LC Stefan
More informationOverview INTELLIGEN ULV DISPENSE SYSTEM. Advanced two-stage system enabling superior dispense and filtration of ultra-low viscosity fluids
CRITICAL MATERIALS HANDLING INTELLIGEN ULV DISPENSE SYSTEM Advanced two-stage system enabling superior dispense and filtration of ultra-low viscosity fluids Overview Building on the proven performance
More information[ Oasis Sample Extraction Products ] SENSITIVITY IN ITS PUREST FORM
[ Oasis Sample Extraction Products ] SENSITIVITY IN ITS PUREST FORM 1 SENSITIVITY in ITS PUREST FORM Combining revolutionary sorbents with innovative hardware, Oasis products are the preeminent choice
More informationSupplementary Information for. A self-cleaning underwater superoleophobic mesh for oil-water separation
Supplementary Information for A self-cleaning underwater superoleophobic mesh for oil-water separation Lianbin Zhang 1, Yujiang Zhong 1, Dongkyu Cha 2 & Peng Wang 1 1 Biological and Environmental Sciences
More informationAqueous GPC Instructions - Detailed
Aqueous GPC Instructions - Detailed Waste Bottle Columns PL Datastream Injection Port GPC Computer UV Detector GPC Pump Eluent Bottle The Aqueous GPC Set Up RI Detector Important The points below must
More informationFLEXIMARK Cable Marking Systems
Custom Plastic Marking Systems 598 UNITRONIC Bus Cables & Connectors MINI/MAXI Plastic Marking Systems 599 Print-Your-Own Plastic Marking Systems 607 Custom Stainless Steel Marking Systems 610 Stainless
More informationDionex ICS-2100 Ion Chromatography System
CHROMATOGRAPHY Thermo Scientific Dionex ICS-2100 Ion Chromatography System Product Specifications The Thermo Scientific Dionex ICS-2100 system is the first Reagent-Free ion chromatography system with electrolytic
More informationFLEXIMARK Cable Marking Systems
Custom Plastic Marking Systems 598 UNITRONIC Bus Cables & Connectors MINI/MAXI Plastic Marking Systems 599 Print-Your-Own Plastic Marking Systems 607 Custom Stainless Steel Marking Systems 610 Stainless
More informationIsolera. User Manual
Isolera User Manual Safety and Document Conventions Isolera system should only be operated and maintained by trained individuals. Please read this manual carefully before working with the system. To guarantee
More informationGRAPHPACK 2M ferrule. The GRAPHPACK 2M ferrule is a cylindrical metal cartridge packed with graphite.
GRAPHPACK GRAPHPACK 2M connection technology For the rapid and economical connection of capillary columns to GC Inlets and Detectors. The components of the GRAPHPACK 2M connection technology are the GRAPHPACK
More informationVersaFlash. Pure...and Simple. High Throughput Flash Purification. VersaFlash Station. VersaPak Cartridges. Sample Loading.
VersaFlash High Throughput Flash Purification VersaFlash Station VersaPak Cartridges Sample Loading VersaVac Manifold Cartridge Stacking and Rev-Elution Pump Kits & Accessories Pure...and Simple 2 VersaFlash
More informationUser Manual. Agilent 1260 Infinity HPLC-Chip Cube Interface (G4240A )
User Manual Agilent 1260 Infinity HPLC-Chip Cube Interface (G4240A ) Notices Agilent Technologies, Inc. 2010, 2012 No part of this manual may be reproduced in any form or by any means (including electronic
More informationInstallation Manual. 1.Included Accessories. System Controller SC-201-6M INT. Requests to Installers *SHA8754 C*
System Controller SC-201-6M INT Installation Manual Potential dangers from accidents during installation and use are divided into the following two categories. Closely observe these warnings, they are
More information600 Micron UV Feedthrough, , on UHV Conflat compatible flange
UV / VIS / IR Multimode Fiber Optic Feedthroughs UV / VIS / IR Multimode Step and Graded-Index 600 micron Air-service Cable*, 105240 600 Micron UV Feedthrough, 105201, on UHV Conflat compatible flange
More informationFanuc. OD8.0 x id4.0 x 10 mm. Power feed contact. Power feed contact. Power feed contact grooved. Upper & lower. Power feeder contact
Fanuc - 1/15 Fanuc - Power Feed Contact F001 A97L-0001-0664 OD25 x id9.0 x 10 mm E. H. K. L. M series F002 A97L-0126-0001 & OD16 x id6.0 x 6.3 mm O. P. Q. R. T. W series F003 A290-8008-X107 & OD8.0 x id4.0
More informationPartner; Democritus University of Thrace (UTHR.DEE.APL) Workpackage; WP 4 and WP 1
First report on Project Assessment of the selected POPs(PCBs,PCDDs/PsPOCPs) in the atmosphere and water ecosystems from the waste generated by warfare in the area of formal Yugoslavia Contract ICA2-CT2002-10007
More informationType. Facts. 441, 442 Full nozzle DIN. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com. Metric Units LWN E
Type 441, 442 DIN Flanged Safety Relief Valves spring loaded Metric Units Facts The-Safety-Valve.com LWN 468.01-E DIN, ANSI 40 Cap H2 19 Lock nut 18 Adjusting screw with bushing 16 Upper spring plate 12
More informationBetafi ne XL. Filter Cartridge Series. Absolute-rated pleated polypropylene fi lters. Lenntech. 3M Purification. Product brochure
3M Purification Product brochure Lenntech info@lenntech.com Tel. +31-152-61-9 www.lenntech.com Fax. +31-152-616-289 Betafi ne XL Filter Cartridge Series Absolute-rated pleated polypropylene fi lters Advanced
More informationOptical Fiber Assemblies
Optical Fiber Assemblies Installation and Operation Instructions Overview Ocean Optics offers an extensive line of standard and premium grade optical fibers and accessories including patch cords, bifurcated
More information9 Maintenance. Agilent Technologies. This chapter describes the maintenance of the module. InfinityLab LC Series Diode Array Detectors User Manual
InfinityLab LC Series Diode Array Detectors User Manual 9 Maintenance Introduction to Maintenance 158 Warnings and Cautions 159 Overview of Maintenance 161 Cleaning the Module 162 Remove and Install Doors
More informationModular Splicing FAX MODULAR SPLICING. Modular Splicing Kits 305 Cable Adapter Kits 308
Modular Splicing Modular Splicing Kits 305 Cable Adapter Kits 308 MODULAR SPLICING 3M Modular Splice Kits form a 5 to 25 kv 600 Amp separable insulated connector system. The system is easy to expand and
More informationAgilent GC/MSD Instructions
Agilent GC/MSD Instructions GC/MS SAMPLE PREPARATION: Sample Components to Avoid Completely: The following should never be injected: metals, strong acids or bases, salts, oligomeric and polymeric material.
More informationIntegral Process Analytical Liquid Chromatography Systems
Systems Integral Process Analytical Liquid Chromatography Systems Integral systems provide a versatile and adaptable approach to process analytical LC systems. An unsurpassed range of IC and HPLC capabilities
More informationHPLC Basics, Equipment, and Troubleshooting
HPLC Basics, Equipment, and Troubleshooting HPLC Basics, Equipment, and Troubleshooting explains chromatography in practical terms from the ground up COURSE HANDOUT: [SECTION 14] Troubleshooting & Diagnostics
More informationMD SERIES. Manual (MD), Quarter Turn (MDQ), Pneumatic (MDA), High Pressure (MDH) Ultra-High Purity Mini-diaphragm Valves
MD SERIES Manual (MD), Quarter Turn (MDQ), Pneumatic (MDA), High Pressure (MDH) Ultra-High Purity Mini-diaphragm Valves MD SERIES These MD Series valves are designed for high performance gas- and chemical-distribution
More informationIn North America, call
OPTICS Selection Guide 75 Fiber Optic Cable Transmission 77 Fiber Optic Cables 78 Chamber-Mounted Vacuum Feedthroughs 79 Chamber-Mounted Optical Couplers 81 In North America, call 1-972-446-9990 73 74
More informationGOLANDER PUMP. Operation Manual. For Microflow Variable-Speed Peristaltic Pump BT50S/BT102S.
GOLANDER PUMP Operation Manual For Microflow Variable-Speed Peristaltic Pump BT50S/BT102S info@golanderpump.com http://golanderpump.com 1-678-587-8806 Contents Safety Cautions... 1 1 Description... 1 2
More information3 Starting the chiral HPLC and logging into LC Real Time Analysis.
Edition: 1.2 Date: 7-Oct-11 Page 1 of 5 1 Responsibilities. First person responsible: Mariëlle Delville. Second person responsible: Helene I.V. Amatdjais-Groenen. 2 Definitions. Read the information on
More informationTél. +41 (0) CH la Chaux-de-Fonds Case postale 2320
AeRO 30 This lightweight, compact, single-hose low pressure, electric blasting system utilizes dry ice pellets in it s patented aerodynamic rotor assuring high reliability and a smooth pulse-free dry ice
More informationThermo Scientific Dionex ICS-5000 HPIC System
Chromatography Thermo Scientific Dionex ICS-5000 HPIC System Modular High-Pressure Capillary Ion Chromatography System Product Specifications The Dionex ICS-5000 HPIC System is the world's first high-pressure
More informationCOOLING OF POWER ELECTRONICS
COOLING OF POWER ELECTRONICS Offering a safe & reliable way to cool semiconductor equipment & applications SOLUTIONS GUIDE Bring us your toughest thermal application challenge MERSEN WILL HELP YOU MAXIMIZE
More informationThe Agilent 5975 inert MSD: New Tools for the Forensic Analyst
The Agilent 5975 inert MSD: New Tools for the Forensic Analyst Chemical Analysis Group Bruce D. Quimby, Ph.D. Senior Applications Chemist Agilent Technologies Wilmington, Delaware March 2,2006 Page 1 The
More informationSOLUTIONS RECERTIFICATION CALIBRATION AND UV/VIS REFERENCE MATERIALS. Photometric and Wavelength Accuracy Reference Material Set
UV/VIS REFERENCE MATERIALS CALIBRATION AND RECERTIFICATION SOLUTIONS Photometric and Wavelength Accuracy Reference Material Set Photometric and Wavelength Accuracy Reference Material Set A set of reference
More informationInsignia - Icon SPARE PARTS CATALOG LASER MARKING SYSTEMS
Insignia - Icon LASER MARKING SYSTEMS 1998-2005 To Order Parts Contact: 1(866) 612-8619 / Fax: (407) 926-3551 or Visit Our Website: TABLE OF CONTENTS Insignia - Icon DESCRIPTION PAGE Insignia Control Cabinet
More informationSputtering Sensor ADVANTAGES
The INFICON is specifically designed for use in any sputtering process. The sensor body and cooling tubes are gold plated beryllium copper for maximum cooling efficiency in the sputtering environment.
More informationMicroreactor Chips. product datasheet
Unit 1, Anglian Business Park, Orchard Road, Royston, Hertfordshire, SG8 5TW, UK T: +44 (0)1763 242491 F: +44 (0)1763 246125 E: sales@dolomite-microfluidics.com W: www.dolomite-microfluidics.com Microreactor
More informationApplication Bulletin 318 e. Installation Instructions of TitrIC 4
The TitrIC 4 System is used for the fully automatic analysis of water samples using direct measurement, titration and ion chromatography. The following parameters are determined in a very short time: temperature,
More informationDPS Differential Pressure Sensors (# #30030)
DPS Differential Pressure Sensors (#30027- #30030) This product enables the remote data collection of differential pressure via standard computer networks. It is useful for real-time data collection from
More informationAccessories Optional Extras to Make Processing Simpler in the Lab. Cartridge Holders. Dry Loading Vessels (DLV)
Accessories Optional Extras to Make Processing Simpler in the Lab Dry Loading Vessels (DLV) Biotage SNAP and flash cartridges are designed with ability to dry load a sample within the cartridge. Sometimes,
More informationOperating Manual. GC-APPI Inferface for:
Operating Manual GC-APPI Inferface for: Q-Exactive TM MS, Exactive TM MS, and LTQ Orbitrap TM Series MS P/N: MC510000, P/N: MC511000, P/N: MC512000 Revision C GC-APPI-Interface 2016 MasCom Technologies
More informationWaters 600E Multisolvent Delivery System Quick Start Guide
Waters 600E Multisolvent Delivery System Quick Start Guide 34 Maple Street Milford, MA 01757 WAT174-04TP, Revision 3 NOTICE The information in this document is subject to change without notice and should
More informationMICRO GC FUSION Micro GC Fusion 3/17/2014 1
MICRO GC FUSION 1 Micro GC Fusion The Next Generation Micro GC 2 Builds on an Innovative Tradition 3000 Micro GC Micro GC Fusion MTI Micro GC 3 Micro GC Fusion Feature Highlight New Chassis Design Aesthetic,
More informationManual for the MicroSIA Instrument
Manual for the MicroSIA Instrument Version 1.1 1 FIAlab Instruments, Inc., 2151 N. Northlake Way, Suite 100, Seattle, WA 98103 USA Table of Contents 1 INTRODUCTION... 3 1.1 GENERAL... 3 1.2 OPERATION PRINCIPLE...
More informationLithotripsy Lithotripsie
Lithotripsy Lithotripsie Injectable Mechanical Lithotripsy System Injectable Mechanical Lithotripsy System Unique StoneBuster Handle User-friendly Twist & Pull Technology Delivers High Basket Tension to
More informationUpchurch Scientific Nano Flow Sensor User s Guide
Upchurch Scientific Nano Flow Sensor User s Guide Oak Harbor, WA 98277 Tel: 800.426.0191 360.679.2528 Fax: 800.359.3460 360.679.3830 Email: customerservice.upchurch@idexcorp.com Internet: www.upchurch.com
More informationSpark Holland introduces
BETTER SAMPLE CARE Spark Holland introduces DBS Autosampler A revolution in Dried Blood Spot (DBS) Sampling Spark Holland introduces DBS Autosampler A revolution in Dried Blood Spot Sampling The DBS Autosampler
More informationThermo Scientific Dionex Aquion Ion Chromatography System
CHROMATOGRAPHY Thermo Scientific Dionex Aquion Ion Chromatography System Product Specifications The Thermo Scientific Dionex Aquion Ion Chromatography (IC) system provides a reliable foundation for IC
More information