1 UPS Status Module For Traffic Applications With GES-102NDM GES-152NDM GES-102NSM Operators Manual Version 1.1

2 THIS PAGE IS INTENTIONALLY BLANK

3 Note The instructions contained in this manual are not intended to cover all of the details or variations in equipment, or to provide for every possible contingency to be met in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes, the matter should be referred directly to Always On UPS Systems Inc. Any electrical or mechanical modifications to this equipment, without prior written consent of Always On UPS Systems Inc, will void all warranties. Unauthorized modifications also can result in personal injury or death or destruction of the equipment. UPS Status Module Please complete the Warranty Card supplied with this device and return it by mail to Always On UPS Systems Inc. This activates the warranty. If additional information or technical assistance is required call: Always On UPS Systems Inc Sales and Technical Support Line Toll free at Ext. 451 or (250) Ext. 451 or Fax (250) Or at sales@alwayson.com or visit our web site at Or write to Always On UPS Systems Inc. Bldg Campion Road, Kelowna, BC, V1X 7S8, Canada Please complete the following information for your records. Model Number: Serial Number: Date of Installation: Inspected By: i

4 IMPORTANT SAFETY INSTRUCTIONS THIS MANUAL CONTAINS IMPORTANT INSTRUCTIONS THAT SHOULD BE FOLLOWED DURING INSTALLATION AND MAINTENANCE. ALL SERVICING MUST BE DONE BY QUALIFIED PERSONNEL. DO NOT ATTEMPT TO SERVICE THIS EQUIPMENT YOURSELF. OPENING OR REMOVING COVERS WILL RISK EXPOSURE TO DANGEROUS VOLTAGES. DO NOT LOCATE MODULE IN AN AREA WHERE UNAUTHORIZED PERSONNEL HAVE ACCESS. DO NOT STAND BEVERAGE CONTAINERS ON THE UNIT. DO NOT USE THIS EQUIPMENT FOR ANY PURPOSE OTHER THAN THE INTENDED USE. ENSURE CABLE PROVIDED IS IN GOOD WORKING CONDITION AND IS NOT DAMAGED OR FRAYED. EXAMINE THE PACKAGING CONTAINER FOR DAMAGE. NOTIFY THE CARRIER IMMEDIATELY IF DAMAGE IS PRESENT. QUALIFIED PERSONNEL SHOULD BE CONSULTED WHEN: 1. LIQUID HAS BEEN SPILLED INTO THE UNIT 2. THE UNIT DOES NOT OPERATE NORMALLY EVEN THOUGH THE OPERATING INSTRUCTIONS HAVE BEEN FOLLOWED. SAVE THESE INSTRUCTIONS SYMBOLS May be used in lieu of the wording caution, risk of electric shock for any cautionary marking. ii

5 Table of Contents 1. INTRODUCTION HANDLING DELIVERY INITIAL INSPECTION STORAGE INSTALLATION MOUNTING CONNECTING TO THE UPS STATUS CONTACT CONNECTION FRONT CONTROL PANEL BUTTON OPERATION STATUSES OF THE MODULE OVERVIEW OF MENUS DESCRIPTION AND OPERATION OF MENUS TECHNICAL DATA CONTACT INFORMATION ADDITIONAL PURCHASES OR UPGRADES QA / WARRANTY QUESTIONS SOFTWARE QUESTIONS iii

6 THIS PAGE IS INTENTIONALLY BLANK iv

7 1. Introduction Congratulations on your choice of complimenting your Always "On" UPS Systems N-Series unit with a state-of-the-art UPS Status Contact Module. The Status Contact Module continually communicates with your UPS to provide operating status via robust 8 Amp, Form C contacts. A timer relay contact is controlled by 14 different timer relay delay settings and a week schedule that is broken down into 336 half-hour intervals. You can assign one of the 14 time delays to each half-hour interval. The time delay countdown is triggered once the ac mains supply to the UPS fails. Other contacts give status for ac mains supply fail and low battery warning conditions. Additional features include a log of 20 power transition events with time stamp. The user interface is easy to navigate and to program a schedule. A PC software package will soon be available for download from our website, further easing the schedule programming. Figure 1: UPS Status Contact Module With UPS 1

8 THIS PAGE IS INTENTIONALLY BLANK 2

9 2. Handling 2.1. Delivery Upon receiving the UPS Status Module, inspect the packaging integrity and the physical condition of the unit carefully. In the event that physical damage is visible, the carrier must be informed immediately and a claim filed with them. Inform Always On as soon as the claim has been filed and a copy of claim should be faxed to Always On at (250) A detailed report of the damage is necessary for your carrier insurance claim Initial Inspection Unpack the unit carefully, and retain the box and packing material. If you must return the unit at any time, you must repack it the way it was originally shipped. Visually inspect the unit for damage that may have occurred during shipment. If there is damage, contact the dealer from whom you purchased the unit, and save the packaging for future shipment. When the unit has passed the initial inspection, record the Installation date on the back panel of the unit and in the space provided in the front of this manual. Included with the system: 1. User manual 2. Communication cable 2.3. Storage 1. If the UPS Status Contact Module is to be stored prior to installation, it should be placed in a dry, well-ventilated area where it will not be exposed to dirt, moisture or other contaminants. 2. Extreme storage temperatures are: a. -40ºC to +74ºC Important: 1. The internal real time clock is supported with a battery and should last approximately 5 years at 25ºC in storage. Expect a shorter lifetime when temperatures exceed 25ºC. 3

10 THIS PAGE IS INTENTIONALLY BLANK 4

11 3. Installation The UPS Status Contact Module is intended for installation in a temperature and humidity controlled indoor environment, free of conductive contaminants. Absolute maximum ambient temperature at sea level must not exceed 74ºC (165ºF). Place the UPS Status Module within the cable length of the UPS. There is very little maintenance required for this unit Mounting There are 2 mounting screw holes to fit a ¼ screw with a ½ head. They are spaced 4 apart. Figure 3.1: Dimensions for Mounting the Status Module 3.2. Connecting to the UPS Connect the Status Module to the UPS with the supplied cable. Figure 3.2: Connecting the Status Module to the UPS 5

12 3.3. Status Contact Connection There are four form-c type relays standard with each unit. The relay functions are as follows: Relay 1 Relay 2 Relay 3 Relay 4 Dynamic Timer Relay Status Utility Failed Status Low Battery Status Future Use The connections are as follows in the figure below. Figure 3.3: Terminal Connections 6

13 4. Front Control Panel Always On UPS Systems Inc. Figure 4.1: LCD Display & Interface 4.1. Button Operation The buttons < and > are used for menu navigation and the button is used for menu selection or accepting changes Statuses of the Module Normal Operation: The AC Power Supply is within operating parameters and the UPS is operating in Online Mode. Utility Fail: The UPS has communicated with the Status Module to tell it that the utility power supply to the UPS has failed. The picture above shows 14 minutes until timer relay closes. This is a real time countdown display. Low Battery: The UPS has communicated with the Status Module to tell it that the battery reserve to the UPS is deemed low. Timer Expires (**FLASH**): The internal timer has counted down and enabled the timer relay. 7

14 Maintenance Mode (**LOCKOUT**): This mode deactivates the timer relay. It is activated/deactivated by pressing the < and > keys simultaneously. This feature may be used if a large extended battery pack is added to the UPS during an extended utility maintenance or outage. Thus a very large battery pack may be used instead of a portable generator. Therefore, if the timer relay is used in conjunction with the flash bus, the intersection will not go into flash in an extended outage. 8

15 4.3. Overview of Menus Various status and programming menus are accessible through the UPS Status Contact Module display; pressing the < and > buttons will scroll through the screens. Selection of a menu is done by pressing. Please note that the select curser indicates a selection by turning lower case letters to upper case letters. Table 4.3.1: Map of Menus 9

16 4.4. Description And Operation of Menus Timer Menu The timer menu provides 14 different programmable time delays. Each programmable time delay is related to a symbol (-, A through M). These timer symbols can be assigned to half-hour intervals throughout the week schedule. When an AC mains failure occurs during a particular half-hour interval, the time delay assigned to that interval will be the duration of the time delay for the timer relay during that outage. If the power returns before the timer expires, the contact will not close and the countdown is stopped. The table can be edited with the < and > and. The following illustrations describe this process. To back out to the main menu at any time, just repeatedly press the < key. Select Timer Edit: Highlight timer using the < or > keys. The selection of timer menu is indicated by the change from timer to TIMER. TIMER can be selected by pressing the key. The Timer splash screen tells you that you have selected the timer menu. Press the > key to go to program the Timers. Choose Timer To Edit: Hit to edit the timer delay value, shown as 1:04. Press the < and > keys to select different timers. Edit Timer Time Delay Values: Then use the < and > keys to change to a different value, in this case, 1:08. Press again to accept the changes as shown below. This is a similar process for all following programming changes. To back out to the main menu at any time, just repeatedly press the < key. 10

17 Schedule Menu The Schedule menu allows the user to schedule the 14 different timer relay delay settings for different time delays throughout the day, depending on what time an AC mains failure occurs. Any of the 14 timers can be assigned to each of the 336 half-hour intervals of the week schedule. The time delay countdown is triggered once the ac mains supply to the UPS fails. If a power outage occurs, the timer relay delay length is governed by the timer symbols (-, A thru M) in that particular half hour interval. The theory behind this feature is that it offers the user to place the intersection into flash to gain a duty cycle and an extended runtime when on battery backup after an extended period of backup. The schedule allows for programming of the timer relay to have different delay times depending on the time of day and day of the week. The table can be edited with the < and > and. To get to the menu, use the similar process illustrated in the first two stages in the Timer Menu progression. Review pictures below. To back out to the main menu at any time, just repeatedly press the < key. Select Schedule Edit: Highlight date using the < or > keys. The selection of schedule menu is indicated by the change from sched to SCHED. SCHED can be selected by pressing the key. Press the > key to continue past the splash screen. Navigate Through The Schedule: This is the view, as you would enter into the schedule menu. Note that the time is illustrated as 00 and is 12:00AM or 00:00. It is a 24-hour clock. Push the < or > to navigate through the schedule time slots. The above illustration shows that the > key has been pushed once to show 12:30AM or 00:30. Change Timers For A Time Slot: Press to change the timer for a particular slot. Then press > to scroll through the days of the week at the selected time. In this case, Friday has been selected because it is upper case. 11

18 Press to select another timer for the weekday that you have chosen. The timer will show up on the right hand side. Choose a timer by scrolling with the < or > keys. In this case, the M timer has been chosen. Press to accept this timer. In this case, the timer M has been selected for Friday at 12:00AM to replace timer -. To back out to the main menu at any time, just repeatedly press the < key. 12

19 Date Menu The Date menu adjusts the year, month, day, weekday, hour and min. The table can be edited with the < and > and. Upon pressing the key the seconds will start at zero. To back out to the main menu at any time, just repeatedly press the < key. Note that for Daylight Savings Time to automatically change correctly, we need all the Date Menu entries entered correctly. Select Date Edit: Highlight date using the < or> keys. The selection of the Date menu is indicated by the change from date to DATE. DATE can be selected by pressing the key. Change Weekday: Press the > key and you will get to Weekday or [WkDay] name change. If you push when on [WkDay], it allows you to change the value. In this case, you can scroll through days of the week. Press to accept the changes. Change Year: Press the > key to view the [Year] edit menu. Push again to adjust as per the [Wkday] change description. Change Month: Press the > key to view the [Mnth] edit menu. Push again to adjust as per the [Wkday] change description. Change Day: Press the > key to view the [Day] edit menu. Push 13

20 again to adjust as per the [Wkday] change description. Change Hour: Press the > key to view the [Hr] edit menu. Push again to adjust as per the [Wkday] change description. Change Minute: Press the > key to view the [Min] edit menu. Push again to adjust as per the [Wkday] change description. Please note that upon pressing again after adjusting the minute reading, the seconds count starts from 0 and may be used for synchronizing with another clock. To back out to the main menu at any time, just repeatedly press the < key. 14

21 Log Menu The Log menu allows the user to view up to 20 events. These events are based on power aberrations noticed by the system. All events are time and date stamped. The table can be viewed with the < and > and keys. To back out to the main menu at any time, just repeatedly press the < key. Select Log Edit: Highlight log using the < or> keys. The selection of log menu is indicated by the change from log to LOG. LOG can be selected by pressing the key. The [Log] splash screen tells you that you have selected the log menu. Press the > key to go to program the Log. View Log Contents: Press < or > to scroll through the log events. A + indicates the AC supply has come back up and is logged with the corresponding time. A - sign indicates AC power failure. The [Log] currently features 20 of the latest events and is cyclical in design. To back out to the main menu at any time, just repeatedly press the < key. 15

22 Bio Menu The Bio menu allows the user to dump and load data, for instance timers and scheduling, from future PC software interface programs. Also, the reset feature resets the timers and schedule to factory defaults. Please note that to make any changes to the Bio EEPROM, one must go to the other menu and set write protect to off. To back out to the main menu at any time, just repeatedly press the < key. Select Bio Edit: Highlight bio using the < or> keys. The selection of the Bio menu is indicated by the change from bio to BIO. BIO can be selected by pressing the key. The [Bio] splash screen tells you that you have selected the bio menu. Press the > key to go to select dump data to PC, load data from PC or reset the UPS Status Module to factory default. Dump Program & Schedule Contents: Press the key to select DUMP, the unit will start to send data through the serial port. Ensure that the unit is connected to the PC and the programming software is running. Load Program & Schedule Contents: Press the key to select LOAD. The unit will wait to receive the proper data through the serial port. Ensure that the unit is connected to the PC and the programming software is running. The figure above shows the data being received. It is complete when the bottom line has sixteen exclamation marks. 16

23 Reset Program & Schedule Contents To Factory Default: Press the key to select RESET. The unit will reset the timers and scheduling to factory default. To back out to the main menu at any time, just repeatedly press the < key. 17

24 ID Menu The ID menu allows editing and viewing of the Identifier title. Recommended ID tag may be the intersection the module is used on. This is a useful feature if you are working on more than one module in the office and do not want the units confused. The table can be edited with the < and > and. To back out to the main menu at any time, just repeatedly press the < key. Select ID Edit: Highlight id using the < or > keys. The selection of ID menu is indicated by the change from id to ID. ID can be selected by pressing the key. The [Id] splash screen displays the current ID. Typical IDs are intersection or main street names. Edit ID Tag: Press the key to enable curser ^. Select the character you want to change with the < or > keys. The character that is to be changed can be selected by pressing the key. Edit ID Tag Continued: Once you press the key, the last character changed appears and can be changed by using the < or > keys. Edit ID Tag Continued: In this case, the < or > keys have been used to change the A to a 1. Edit ID Tag Continued: Press the key to save the 1 in the selected place. To back out to the main menu at any time, just repeatedly press the < key. 18

25 Other Menu The Other features menu allows the user to view the last power failure and return, the serial number, daylight savings on or off, write-protect stored data and link M timer to relay four or not. The table can be edited with the < and > and. Select Other Menu: Highlight other using the < or > keys. The selection of Other menu is indicated by the change from other to OTHER. OTHER can be selected by pressing the key. The [Other] splash screen displays that you are in the Other features menu View Last Time AC Supply Power Returned: View the last time supply AC power returned from an outage to the UPS input. Press the < or > keys to view the next screen. View Last Time AC Supply Power Failed: View the last time an outage of supply AC to the UPS input occurred. Press the < or > keys to view the next screen. View First Power Up: View the first time the unit was powered up. Press the < or > keys to view the next screen. Firmware Build: This shows the firmware version and serial number, listed as a time stamp. For factory use. Press the < or > keys to view the next screen. 19

26 Daylight Savings: Currently shows that Daylight Savings is ON. Daylight Savings Time is displayed as a semi-colon in the time display; otherwise, it is a colon. Press the < or > keys to view the next screen. Enable M-Timer to activate Relay 4: Currently not featured and is for future use. Enable M-Timer to activate Relay 4 for 60 seconds: Currently not featured and is for future use. Enable Write Protect of EEPROM Memory: Allow or restrict overwriting of memory when using the Bio menu. Toggle On or Off by pressing the key. Press the < or > keys to view the next screen. 20

27 5. TECHNICAL DATA Temperature Range Unit Voltage Contacts Clock Battery Physical -40 C to +74 C 12VDC Nominal, 15VDC Maximum 120VAC - 8A or ½ Hp Maximum, 24VDC-8A Maximum ~5 years on C (WxDxH) x1.125 x

28 6. CONTACT INFORMATION 6.1. Additional Purchases or Upgrades Always On UPS Systems Inc. Bldg Campion Road, Kelowna, BC, Canada, V1X 7S8 Phone: (250) Ext 451 Fax: (250) sales@alwaysonups.com Website: QA / Warranty Questions Always On UPS Systems Inc. Bldg Campion Road, Kelowna, BC, Canada, V1X 7S8 Phone: (250) Ext 209 Fax: (250) qa@alwaysonups.com Website: Software Questions Always On UPS Systems Inc. Bldg Campion Road, Kelowna, BC, Canada, V1X 7S8 Phone: (250) Ext 204 Fax: (250) webmaster@alwaysonups.com Website: 22

UPS READY POWER DISTRIBUTION ASSEMBLY

UPS READY POWER DISTRIBUTION ASSEMBLY UPS READY POWER DISTRIBUTION ASSEMBLY FOR TRAFFIC CABINETS with LED Signals INSTALLATION & OPERATOR S MANUAL VERSION 1.2 1 Note The instructions contained in this manual are not intended to cover all of

More information

Always "On" UPS Systems Inc. USER MANUAL

Always On UPS Systems Inc. USER MANUAL Always "On" UPS Systems Inc. SMART HOME PROTECTOR USER MANUAL Bldg 1-150 Campion Road, Kelowna, BC, Canada, V1X 7S8 Phone: (250) 491-9777 Ext. 451, Fax: (250) 491-9775, Email: sales@alwaysonups.com Web

More information

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English Configurable Output Distribution 120V / 208V / 240V 60Hz User Manual English TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS.......................... 1 GLOSSARY OF SYMBOLS....................................

More information

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Important Safety Information Read the instructions carefully to become familiar with the equipment before trying to install, operate, service

More information

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 120 Volt

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 120 Volt POWER AVAILABILITY 2U POD USER MANUAL Power Output Distribution 120 Volt TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS.......................................... 1 GLOSSARY OF SYMBOLS..................................................

More information

DCM Digital Control Modules

DCM Digital Control Modules DCM Digital Control Modules TECHNICAL MANUAL Version 1.2 November 2011 Safety Precautions Caution Read Instructions: Read and understand all safety and operating instructions before using the equipment.

More information

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 230 Volt

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 230 Volt POWER AVAILABILITY 2U POD USER MANUAL Power Output Distribution 230 Volt TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS.......................................... 1 GLOSSARY OF SYMBOLS..................................................

More information

DVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8

DVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8 DVI KVM Extra Long Range Extender Over One CAT5 EXT-DVIKVM-ELR User Manual Release A8 Important Safety Instructions 1 Read these instructions 2 Keep these instructions 3 Heed all warnings 4 Follow all

More information

TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE...

TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE... TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE... 3 1.0 General Information... 5 1.1 System Components... 5 1.2 Specifications... 5 1.2.1 Torque Ranges...

More information

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE XBDM 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL www.xpcc.com 2013 Xtreme Power Conversion Corporation. All rights reserved. Table of Contents IMPORTANT SAFETY INSTRUCTIONS:... 4 INTRODUCTION...

More information

Model P4470 Save A Watt Operation Manual

Model P4470 Save A Watt Operation Manual Model P4470 Save A Watt Operation Manual Thank you for purchasing the P4470 Save A Watt. This operating manual will provide an overview of the product, safety instructions, a quick guide to operation,

More information

Stage Fog Machine User Manual

Stage Fog Machine User Manual M-4 Stage Fog Machine User Manual English 2014 Antari Lighting and Effects Ltd. 1 2 Safety Information Please read the following safety information carefully before operating the machine. Information includes

More information

OPERATING INSTRUCTIONS AND SERVICE MANUAL BASKETBALL SHOTCLOCK MODEL MP-5299

OPERATING INSTRUCTIONS AND SERVICE MANUAL BASKETBALL SHOTCLOCK MODEL MP-5299 OPERATING INSTRUCTIONS AND SERVICE MANUAL BASKETBALL SHOTCLOCK MODEL MP-5299 EFFECTIVE S.N. 17,000, December, 2000 TABLE OF CONTENTS 1. General Information 1.1 Description 1.2 Identification 1.3 Damage

More information

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

CA846 THERMO-HYGROMETER ENGLISH. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

CA846 THERMO-HYGROMETER ENGLISH. User Manual. 99 Washington Street Melrose, MA Phone Toll Free THERMO-HYGROMETER CA846 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com ENGLISH User Manual Statement of Compliance Chauvin Arnoux,

More information

TDM-170 TIMER DISPLAY

TDM-170 TIMER DISPLAY TDM-170 TIMER DISPLAY TECHNICAL MANUAL Version 1.1 August 2016 TDM-170 Timer Display Technical Manual Safety Precautions Caution Read Instructions: Read and understand all safety and operating instructions

More information

PSC-10A Programmable Smart Charger. User's Guide

PSC-10A Programmable Smart Charger. User's Guide PSC-10A Programmable Smart Charger User's Guide 990 South Rogers Circle, Suite 11 Boca Raton, FL 33487 Tel: 561-997-2299 Fax: 561-997-5588 www.alber.com Safety Information Except as explained in this manual,

More information

Service Instructions. Conductor 420

Service Instructions. Conductor 420 Service Instructions Conductor 420 Listed, File No. E195547 Input: 480 VAC, 50/60 HZ. (Operating range 380-480 VAC) 20 AMP MAX OUTPUT W/25 AMP FUSE Output: 0-90% of Input Voltage Table of Contents General

More information

TO AVOID FIRE, SHOCK, OR DEATH; SHUT OFF POWER SUPPLY AT THE CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING.

TO AVOID FIRE, SHOCK, OR DEATH; SHUT OFF POWER SUPPLY AT THE CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING. OWNER S MANUAL Congratulations on your purchase of a UPM timer. Please take the time to read and understand this manual so you can begin to enjoy the security and energy saving benefits this product has

More information

W-715 Fog Jet USER MANUAL English 2013 Antari Lighting and Effects Ltd.

W-715 Fog Jet USER MANUAL English 2013 Antari Lighting and Effects Ltd. W-715 Fog Jet USER MANUAL English 2013 Antari Lighting and Effects Ltd. 1 2 Safety Information Please read the following safety information carefully before operating the machine. Information includes

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A

More information

8 Button RS232/IR. Control Panel. MuxLab Inc A / SE A

8 Button RS232/IR. Control Panel. MuxLab Inc A / SE A 8 Button RS232/IR Control Panel 500816 MuxLab Inc. 2016 94-000833-A / SE-000833-A SAFETY PRECAUTIONS To insure the best use from the product, please read all instructions carefully before using the device.

More information

TDM-150 TIMER DISPLAY

TDM-150 TIMER DISPLAY TDM-150 TIMER DISPLAY TECHNICAL MANUAL Covers TDM-150D, TDM-150F Version 1.1 August 2016 Safety Precautions Caution Read Instructions: Read and understand all safety and operating instructions before using

More information

TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE...

TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE... TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE... 2 1.0 General Information... 3 1.1 System Components... 3 1.2 Specifications... 3 1.2.1 Torque Ranges... 3 1.2.2 Electrical Specifications...

More information

SOLARIMMERSION IV Advanced Installation Manual v1.9

SOLARIMMERSION IV Advanced Installation Manual v1.9 SOLARIMMERSION IV Advanced Installation Manual v1.9 1 Contents 1. Overview 2. Technical Specifications 3. Installation Mounting Electrical Installation Clamp Installation Wiring Diagrams 4. Installation

More information

Owner s Instruction Manual

Owner s Instruction Manual Owner s Instruction Manual Advanced Healthcare Telephone Model 5150 Contents IMPORTANT SAFETY INSTRUCTIONS...3 BOX CONTENTS...4 FEATURES...4 ON/OFF SWITCH...4 DIAL BUTTONS...4 RECEIVER VOLUME CONTROL...4

More information

7 Digital Photo Frame

7 Digital Photo Frame 7 Digital Photo Frame Instruction manual L7DPF17 12 month manufacturer's warranty -------------------------------------------------------------------------- --------------------------------------------------------------------------

More information

CL600 SIMPLE LOGGER RMS CLAMP-ON MODULE E N G L I S H. User Manual

CL600 SIMPLE LOGGER RMS CLAMP-ON MODULE E N G L I S H. User Manual SIMPLE LOGGER RMS CLAMP-ON MODULE CL600 E N G L I S H User Manual Owner s Record The serial number for the Simple Logger Model CL600 is located on the back of the instrument. Please record this number

More information

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs) Models beginning with 2M, 2L or 2X Series 2000 Multiple Meter Units (MMUs) Product Description Technical Specifications Installation Instructions February 28 th, 2013 List of Figures...2 List of Tables...2

More information

MAXIMA+ Series Rotary Level Indicator

MAXIMA+ Series Rotary Level Indicator MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE

More information

Robot Light V2. User Manual

Robot Light V2. User Manual Robot Light V2 User Manual 2 Please read over this manual before operating the light. Introduction Unpacking: Thank you for purchasing the Robot Light V2. Every Robot Light V2 has been thoroughly tested

More information

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL 1 IMPORTANT SAFETY INSTRUCTION READ FIRST This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure-voltage

More information

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only. Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 (440) 248-0400 Fax: (440) 248-6168 www.keithley.com Model 4200-RM Rack Mount Kit Packing List Introduction NOTE This 4200-RM Rack Mount

More information

MODEL 9386 MULTI-SPORT TIMER

MODEL 9386 MULTI-SPORT TIMER MODEL 9386 MULTI-SPORT TIMER Instruction Manual Address: 34 Main Street, Whitesboro, NY 13492 Phone: 315-736-3967 Toll Free: 800-383-6060 Fax: 315-736-4058 SCOREBOARDS TIMERS MESSAGE SIGNS VIDEO DISPLAYS

More information

MV SERIES MACHINE VISION STROBOSCOPE. Operating Manual

MV SERIES MACHINE VISION STROBOSCOPE. Operating Manual MACHINE VISION STROBOSCOPE MV SERIES Operating Manual ELECTROMATIC Equipment Co., Inc. 600 Oakland Ave Cedarhurst, NY 11516 - USA TEL (800) 645-4330 (516) 295-4300 FAX (516) 295-4399 Email: info@checkline.com

More information

GI-4000 User Manual. Kobetron, Inc. P.O. Box 5489 Navarre, FL 32566

GI-4000 User Manual. Kobetron, Inc. P.O. Box 5489 Navarre, FL 32566 GI-4000 User Manual Kobetron, Inc. P.O. Box 5489 Navarre, FL 32566 TEL: (850) 939-5222 FAX: (850) 939-0490 EMAIL: sales@kobetron.com WEB: www.kobetron.com "Testing Tomorrow's Technology Today" TABLE OF

More information

User Manual SP2-4K. 4K HDMI Splitter 1x2. All Rights Reserved. Version: SP2-4K_2016V1.0

User Manual SP2-4K. 4K HDMI Splitter 1x2. All Rights Reserved. Version: SP2-4K_2016V1.0 User Manual SP2-4K 4K HDMI Splitter 1x2 All Rights Reserved Version: SP2-4K_2016V1.0 SAFETY PRECAUTIONS To insure the best from the product, please read all instructions carefully before using the device.

More information

Model 2380 Rack-Mount Kit

Model 2380 Rack-Mount Kit Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 2380 Rack-Mount Kit Installation Instructions Introduction The Model 2380 Fixed Rack-Mount

More information

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit

More information

D-Pack 6 Classic ORDERCODE 50315

D-Pack 6 Classic ORDERCODE 50315 D-Pack 6 Classic ORDERCODE 50315 Congratulations! You have bought a great, innovative product from Showtec. The Showtec D-Pack 6 Classic brings excitement to any venue. Whether you want simple plug-&-play

More information

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 8020-STC Kelvin Standard Triaxial Connector Card Description The Model 8020-STC Kelvin Standard

More information

Model 2380 Rack-Mount Kit

Model 2380 Rack-Mount Kit Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 2380 Rack-Mount Kit Installation Instructions Introduction The Model 2380 Fixed Rack-Mount

More information

actilib Library 2U Quick Start Guide

actilib Library 2U Quick Start Guide actilib Library 2U Quick Start Guide September, 2009 1 Contents 1 Contents...2 2 Warnings and symbols...3 2.1 Precautions...4 2.2 Product Warranty Caution...4 2.3 Rack stability...4 3 Unpacking the tape

More information

Z-380 Fazer Machine User Manual English

Z-380 Fazer Machine User Manual English Z-380 Fazer Machine User Manual English 2015 Antari Lighting and Effects Ltd. User Manual Safety Information Please read the following safety information carefully before operating the machine. Information

More information

TH2683 Insulation Resistance Meter. User s Mannual

TH2683 Insulation Resistance Meter. User s Mannual TH2683 Insulation Resistance Meter User s Mannual 1 CONTENTS Chapter 1 Genernal Information... 3 1.1 Feature Overview... 3 1.2 Operating Environment... 3 1.3 Dimensions and Weight... 3 1.4 Unpacking Inspection...

More information

Sidewinder Pumps Inc. AC C1D2 Timer/Controller

Sidewinder Pumps Inc. AC C1D2 Timer/Controller Sidewinder Pumps Inc. AC C1D2 Timer/Controller Page 1 of 14 Rev 4/26/17 Table of Contents 1. Warnings --------------------------------------------------------------------------------------------------

More information

User Manual. Stoltzen SHSP14 HDMI Splitter 1x4. 4K HDMI Splitter 1x4. All Rights Reserved. Version: SHSP14_2016V2

User Manual. Stoltzen SHSP14 HDMI Splitter 1x4. 4K HDMI Splitter 1x4. All Rights Reserved. Version: SHSP14_2016V2 User Manual 4K HDMI Splitter 1x4 All Rights Reserved Version: SHSP14_2016V2 SAFETY PRECAUTIONS To insure the best from the product, please read all instructions carefully before using the device. Save

More information

PS8 - II. Professional Power Sequencer. User s Manual

PS8 - II. Professional Power Sequencer. User s Manual PS8 - II Professional Power Sequencer User s Manual IMPORTANT SAFETY INSTRUCTIONS READ FIRST This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure.

More information

DVI Detective. User Manual EXT-DVI-EDIDN. Release A3

DVI Detective. User Manual EXT-DVI-EDIDN. Release A3 DVI Detective EXT-DVI-EDIDN User Manual Release A3 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use

More information

TS-ADA-029. Wireless Tone Generator. User's Manual / Installation Guide. Version 1.03

TS-ADA-029. Wireless Tone Generator. User's Manual / Installation Guide. Version 1.03 TS-ADA-029 Wireless Tone Generator User's Manual / Installation Guide Version 1.03 Visiplex, Inc. 2012 TS-ADA-029 Wireless Tone Generator Copyright The product described in this manual includes copyrighted

More information

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only. Concorde 600 Power Supply Operation Manual Cat.no. R10-1001011 *This instrument is intended for laboratory use only http://www.recenttec.com E-mail : support@recenttec.com Version 1.1 Packing List x 1

More information

SATA II HDD Canister KISS DA 435 Quick Reference Guide

SATA II HDD Canister KISS DA 435 Quick Reference Guide SATA II HDD Canister KISS DA 435 Quick Reference Guide If it s embedded, it s Kontron 1. Table of Contents SATA II HDD Canister KISS DA 435 1. Table of Contents 1. Table of Contents... 1 2. Important Information...

More information

User Manual for the Antari M-1 Mobile Fog Machine. Congratulations on the purchase of your new ANTARI M-1 Mobile Fog Machine

User Manual for the Antari M-1 Mobile Fog Machine. Congratulations on the purchase of your new ANTARI M-1 Mobile Fog Machine User Manual for the Antari M-1 Mobile Fog Machine Congratulations on the purchase of your new ANTARI M-1 Mobile Fog Machine Save and read these instructions Bitte lesen Sie und sichern Sie diese Anweisungen

More information

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power Critical Power USER MANUAL Uninterruptible Power Supply Line-interactive VCL Series UPS 400 600 800 1000 1500 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland

More information

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide 2004-2009, AFL Telecommunications, all rights reserved. COM4-00-1001 Revision E, 2009-06-16 Specifications

More information

Flat Par 9 LEDs. battery power, Wirelss, Remote Control, RGBWA-UV 6-in-1 USER MANUAL. Please read over this manual before operating the light

Flat Par 9 LEDs. battery power, Wirelss, Remote Control, RGBWA-UV 6-in-1 USER MANUAL. Please read over this manual before operating the light Flat Par 9 LEDs battery power, Wirelss, Remote Control, RGBWA-UV 6-in-1 USER MANUAL Please read over this manual before operating the light 6CH Mode Value Description CH1 1-255 RED dimmer CH2 1-255 GREEN

More information

MDM 011-Z1 Regen Resistor

MDM 011-Z1 Regen Resistor MDM 011-Z1 Regen Resistor Date of creation: 10.04.2017 Version date: 10.04.2017 Article number: 09-402-011-Z1-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax: 06274/4321-18

More information

MPF-1, Mains Power Filter User Manual

MPF-1, Mains Power Filter User Manual 1/7 Important Safety Information 2/7 Protect the power cable from being walked on or pinched particularly at the plugs, convenience receptacles, and at the point where they exit from the apparatus. Refer

More information

Advidia A-15 & A-35 Installation Manual

Advidia A-15 & A-35 Installation Manual Advidia A-15 & A-35 Installation Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual may contain inaccuracies

More information

Quick Start Guide TS A

Quick Start Guide TS A Quick Start Guide TS 930 125-630A DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer

More information

COBEX RECORDERS, INC.

COBEX RECORDERS, INC. INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS FOR CIRCULAR CHART RECORDERS COBEX RECORDERS, INC. CAUTION: IT IS IMPORTANT THAT THESE INSTRUCTIONS BE READ BEFORE INSTALLING THE INSTRUMENT. KEEP THESE

More information

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-CH Rev. X1 E-Mail: salessupport@olsontech.com

More information

FCC Regulatory Information

FCC Regulatory Information DVW32C Advanced Wireless Voice Gateway - Safety and Installation Product Insert Federal Communications Commission (FCC) Interference Statement This equipment has been tested and found to comply with the

More information

HDMI Extender over Cat5e/6

HDMI Extender over Cat5e/6 Statement Thanks for purchasing this product, please read this user manual carefully before using this product.in the constant effort to improve our product, we reserve the right to make functions or parameters

More information

VIP-812A DUAL NETWORKED STATION PORT

VIP-812A DUAL NETWORKED STATION PORT ISSUE 1 VIP-812A DUAL NETWORKED STATION PORT INTRODUCTION The VIP-812A Dual Networked Station Port allows most loop start terminal devices to be connected to a managed IP-based LAN/WAN. SPECIFICATIONS

More information

QUICK START USER GUIDE. Data Logger Model L452

QUICK START USER GUIDE. Data Logger Model L452 QUICK START USER GUIDE Data Logger Model L452 Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments traceable

More information

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH) Surge-Trap STZ-R series Surge Protective Device (SPD) Danger Hazard of Electrical Shock, Explosion or Arc Flash Only qualified licensed electricians should install or service SPDs Verify that all power

More information

Manual. NanoTron Dual Timer. Installation Maintenance Repair Manual

Manual. NanoTron Dual Timer. Installation Maintenance Repair Manual Manual NanoTron Dual Timer Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com email: support@advantagecontrols.com

More information

Source-Transfer Application Guide

Source-Transfer Application Guide S&C Model 6802 Automatic Switch Control Source-Transfer Application Guide Table of Contents Section Page Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this

More information

Cluster FX-Bar. Portable performance lighting and laser rig

Cluster FX-Bar. Portable performance lighting and laser rig Cluster FX-Bar Portable performance lighting and laser rig Due to continuous product development, please ensure that you have downloaded the latest instruction manual for this product from the AVSL website

More information

GCI-5K INSTALLATION AND OPERATOR S MANUAL

GCI-5K INSTALLATION AND OPERATOR S MANUAL GCI-5K INSTALLATION AND OPERATOR S MANUAL Grid-tied inverter for wind Ningbo Ginlong Technologies 1 INTRODUCTION 2 SAFETY GUIDELINES AND WARNINGS 3 INSTALLATION 3.1 Selecting a location for the inverter

More information

User's Guide. Extech AM A AC Analog Clamp Meter

User's Guide. Extech AM A AC Analog Clamp Meter User's Guide Extech AM300 300A AC Analog Clamp Meter Introduction Congratulations on your purchase of the Extech AM300 Analog Clamp Meter. This device measure AC Voltage and Current, DC Voltage, and Resistance.

More information

COOPER POWER SERIES. Input/Output (I/O) module installation instructions. Voltage Regulators MN225067EN

COOPER POWER SERIES. Input/Output (I/O) module installation instructions. Voltage Regulators MN225067EN Voltage Regulators MN225067EN Effective November 2016 Supersedes June 2014 (S225-70-13) COOPER POWER Input/Output (I/O) module installation instructions SERIES DISCLAIMER OF WARRANTIES AND LIMITATION OF

More information

PA39085 INSTRUCTION MANUAL

PA39085 INSTRUCTION MANUAL Power Meter Model Number: PA39085 INSTRUCTION MANUAL Power Meter Warranty Details The product is guaranteed to be free from defects in workmanship and parts for a period of 12 months from the date of purchase.

More information

Octostrip ORDERCODE 42220

Octostrip ORDERCODE 42220 Octostrip ORDERCODE 42220 Congratulations! You have bought a great, innovative product from Showtec. The Showtec LED Octostrip brings excitement to any venue. Whether you want simple plug-&-play action

More information

Prestigio P371 Users manual

Prestigio P371 Users manual Prestigio P371 Users manual 1. IMPORTANT INFORMATION WARNING: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS MONITOR TO LIQUIDS OR MOISTURE. HIGH VOLTAGE EXISTS ON THIS MONITOR. DO NOT REMOVE THE

More information

Instructions. TLA5Fxxx, TLA6Fxx, & TLA7Fxx PowerFlex Field Upgrade Kits for TLA5000, TLA600, and TLA700 Logic Analyzers

Instructions. TLA5Fxxx, TLA6Fxx, & TLA7Fxx PowerFlex Field Upgrade Kits for TLA5000, TLA600, and TLA700 Logic Analyzers Instructions TLA5Fxxx, TLA6Fxx, & TLA7Fxx PowerFlex Field Upgrade Kits for TLA5000, TLA600, and TLA700 Logic Analyzers 071-0591-05 This document applies to TLA System Softwareversion 3.2 and above. www.tektronix.com

More information

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

VE8014A/VE8014AR QUAD NETWORKED STATION PORT ISSUE 2 VE8014A/VE8014AR QUAD NETWORKED STATION PORT INTRODUCTION The VE8014A/VE8014AR Quad Networked Station Port allows most loop start terminal devices to be connected to a managed IP-based LAN/WAN.

More information

high RESISTANCE STOPLIGHT Instruction Manual C-101EM

high RESISTANCE STOPLIGHT Instruction Manual C-101EM stoplight high RESISTANCE GROUNDING SYSTEM STOPLIGHT Instruction Manual C-101EM high resistance grounding protection The StopLight system uses a unique indicator light system to provide visual detection

More information

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24 Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24 Section Page Introduction 1 Materials Provided 1 I) Safety Instructions 1 A) Inverter Safety Instructions 1 B) Battery Safety

More information

Allen-Bradley Real Time Clock Module (Cat. No DC)

Allen-Bradley Real Time Clock Module (Cat. No DC) Allen-Bradley (Cat. No. 1771-DC) Product Data Description The (cat. no. 1771-DC) allows you or the PC processor to read or set real time and date information. Real time and date information is block transferred

More information

HV-CS kv Edge Mount Triaxial Jack

HV-CS kv Edge Mount Triaxial Jack Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley HV-CS-1589 3 kv Edge Mount Triaxial Jack Installation Information Description The Keithley Instruments

More information

2260B-RMK-Series Rack Mount Kit

2260B-RMK-Series Rack Mount Kit Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Assembly and Mounting Instructions Introduction The 2260B-RMK-Series Rack Mount Kit is suited for

More information

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 8020-KHV Kelvin Keithley Triaxial Connector Card Description The Model 8020-KHV Keithley HV Connector

More information

Operating Instructions & Service Manual FOULS

Operating Instructions & Service Manual FOULS FOULS Operating Instructions & Service Manual FOULS Basketball Player Fouls Panels Model MP-5215 EFFECTIVE S.N. 17,100, June 18, 2001 TABLE OF CONTENTS PAGE 1. GENERAL INFORMATION 3 1.1 DESCRIPTION 1.2

More information

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL PHASETRONICS Specialists EP1 Series Power Control Single Phase SCR 10-50 Amps OPERATION & SERVICE MANUAL Phasetronics, Inc. P.O. Box 5988 1600 Sunshine Drive Clearwater, FL 33765 (727)573-1900 FAX(727)573-1803

More information

N4 Art-Net Node. Order code: CONT25. User Guide Please read these instructions carefully before use

N4 Art-Net Node. Order code: CONT25. User Guide Please read these instructions carefully before use N4 Art-Net Node Order code: CONT25 User Guide Please read these instructions carefully before use CONTENTS 1. Features 2 2. General Instructions 3 3. Overview 4 3.1 Front View 4 3.2 Rear View 4 4. Operation

More information

SMI-100 Stack Monitoring Interface Installation & Operation Manual

SMI-100 Stack Monitoring Interface Installation & Operation Manual SMI-100 Stack Monitoring Interface Installation & Operation Manual Aquion Energy, Inc. 32 39th Street Pittsburgh, PA 15201 +1 412.904.6400 aquionenergy.com AQ-OP-00015_C 12.23.16 2016 Aquion Energy, Inc.

More information

P4472 Save A Watt HD Operation Manual

P4472 Save A Watt HD Operation Manual P4472 Save A Watt HD Operation Manual Thank you for purchasing the P4472 Save A Watt HD. This operating manual will provide an overview of the product, safety instructions, a quick guide to operation,

More information

User Manual TL-FO-HD. 4K Optical Fiber Extender. All Rights Reserved. Version: TL-FO-HD_160628

User Manual TL-FO-HD. 4K Optical Fiber Extender. All Rights Reserved. Version: TL-FO-HD_160628 User Manual TL-FO-HD 4K Optical Fiber Extender All Rights Reserved Version: TL-FO-HD_160628 Preface Read this user manual carefully before using this product. Pictures shown in this manual is for reference

More information

User Manual. Terrestrial DVB-T/T2 to IPTV Converter CT2IP-8032

User Manual. Terrestrial DVB-T/T2 to IPTV Converter CT2IP-8032 User Manual Terrestrial DVB-T/T2 to IPTV Converter CT2IP-8032 ZyCast Technology Inc. No. 33, Lane 181, Chung Hwa Road Section 4, Hsin Chu, Taiwan 30060 Tel: +886-3-5400-949 Fax: +886-3-5400-413 E-mail:

More information

Model 7705 Control Module

Model 7705 Control Module www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be

More information

L610 L620 L630 SIMPLE LOGGER THERMOCOUPLE MODULE E N G L I S H. User Manual

L610 L620 L630 SIMPLE LOGGER THERMOCOUPLE MODULE E N G L I S H. User Manual SIMPLE LOGGER THERMOCOUPLE MODULE L610 L620 L630 E N G L I S H User Manual Owner s Record The serial number for the Models L610, L620 and L630 is located on the side of the case. Please record this number

More information

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models TOT Series Manual North American CE and UK Models CE Models UK Models North American Models Table of Content 1. Important Safety Instructions 2. Description Shipping Carton & Packing Material Placement

More information

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities MiG2 CONTROLLERS 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities The MiG2 controllers incorporate: 2 Inputs (Configurable as Resistive, 0 10V, 0 20mA or 4 20mA) 2 or 4 Relay Outputs

More information

Breaker Panel Technical Practice NPDRP1114

Breaker Panel Technical Practice NPDRP1114 030-000218 REV E 1114-03E January 30, 2013 Westell Breaker Panel Technical Practice NPDRP1114 FEATURES DIN rail panel accepts up to 6 DIN rail devices (one surge and 5 breakers) Specific configuration

More information

QUICK START. Installation & Programming Guide

QUICK START. Installation & Programming Guide QUICK START Installation & Programming Guide PRECAUTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. CAUTION - RISK OF ELECTRICAL SHOCK. To prevent electrical shock, turn off power at the circuit breaker

More information

LP3 Multipurpose Laser Presenter

LP3 Multipurpose Laser Presenter LP3 Multipurpose Laser Presenter User Manual Table of Contents 1. IMPORTANT SAFETY INSTRUCTIONS 2 2. PACKAGE CONTENTS 4 3. PART NAMES AND FUNCTIONS 4 4. SETUP AND INSTALLATION 5 5. BASIC OPERATION 5 6.

More information

NIMBUS a personal dashboard for your digital life

NIMBUS a personal dashboard for your digital life INVENTED BY REAL PEOPLE LIKE YOU Ryan Pendleton NIMBUS a personal dashboard for your digital life OVERVIEW Part of the Quirky + GE collection of smart products, Nimbus is a highly customizable 4-dial clock

More information

Touchpad User Guide. National Sales. Product Support. Freecall: Ph:

Touchpad User Guide. National Sales. Product Support. Freecall: Ph: Touchpad User Guide National Sales Ph: 1300 306 125 sales@ias.net.au Product Support Freecall: 1800 354 434 support@ias.net.au Designed and Manufactured in Australia by: Innovative Air Systems Pty Ltd.

More information