Blower and EC-filters
|
|
- Brice Curtis
- 5 years ago
- Views:
Transcription
1 Blower and EC-filters The blower and EC-filter is an under- and over-pressure filter, designed for continuous operation.constructed as a self-supporting sheet metal construction. The round design ensures great strength combined with low weight. Surface Powder coated to corrosion class C3 cf. ISO Inlet The Blower and Jet filters are fitted with 180º tangential inlets to ensure effective sorting of heavy materials before the process air passes through the filter medium. B-34, 36, 55, 60, 84 and 90-filters are also available with total separators. Standard height is mm, with the inlet at 90ºC. This type of inlet is used in plants in which the process air contains heavy and sharp articles to prevent them coming into contact with the filter medium. Cleaning system B-36, 60, 84, 90 ET filters are available with PowerPulse or Blower cleaning. B-8, 12,, 34, 55 filters are supplied with EC-cleaning. ischarge system Conical or scraper bottoms are available for the discharge system, but silo filter is also available. TEX B-8, 12,, 34, 55 filters with EC-cleaning and side venting. B-36, 60, 84, 90 filters with PowerPulse cleaning, external compressed air or internal compressor are equipped with approved explosion membranes. Choose between side venting or JK s specially developed VV explosion relief venting, which vents explosion pressure vertically through the filter top. Operating range Pressure: +/ Pa (available up to + kpa to -10 kpa) ilter area: m² Max. operating temperature: 70ºC Min. operating temperature: -ºC (available for: -40 ºC) Connection ear motor Blower-cleaning: Type 36: 0.25 kw, min -1, 3 x 400 V, 50 Hz, 1.1 Type 60, 84 and 90: 0.25 kw, 6.3 min -1, 3 x 400 V, 50 Hz, 0.82 Cleaning fan Type 36: 5.5 kw, 2860 min -1, 3 x 400 V, 50 Hz, 11 Type 60: 7.5 kw, 2880 min -1, 3 x 400 V, 50 Hz, 14.5 Type 84 and 90: 11.0 kw, 2900 min -1, 3 x 400 V, 50 Hz, Connection EC filter control system B-8, 12,, 34, 55: 0,25 kw, 1 x 230 V, 50 Hz, 0,1 Inductive sensor, Blower-cleaning: 24 VC ear motor PowerPulse cleaning system: 0.12 kw, 15.6 min -1, 3 x 230 V, 50 Hz, 0.7 ear motor scraper bottom: Type : 0.25 kw, 15.7 min -1, 3 x 400 V, 50 Hz, 1.1 Type 34, 36: 0.55 kw, 11.0 min -1, 3 x 400 V, 50 Hz, 1.7 Type 55, 60, 84 and 90: 0.75 kw, 11.0 min -1, 3 x 400 V, 50 Hz, 2.2 Inductive sensor, scraper bottom: 24 VC B-filter with scraper bottom and tangential inlet. Shown with explosion relief venting in side. With ladder and platform mounted. B-filter with scraper bottom and tangential inlet. Shown with VV explosion relief venting in the filter top. itted with ladder and platform.
2 Blower- and EC-filtre PowerPulse- ECOTROL filter control system, B-CT-ET: 0.6 kw, 1 x 230 V, 50 Hz, 1.9 External compressed air - PowerPulse : 5 bar, min. 350 Nl/min. ir quality according to ISO : Quality class ( ) External connection: ¼ internal thread. Type designations ilters are type-designated using a combination of letters and numbers separated by hyphens and spaces. esignation B-36CT-ET S VV 3.0-R therefore describes a Blower filter with 36 filter bags, PowerPulse cleaning system with ET, scraper bottom, vertical explosion relief venting, 3 m filter bag and right inlet. Internal compressor - PowerPulse : 2.2 kw, 3 x 400 V, 50 Hz, 5.9 Capacity: 350 Nl/min. Noise Noise level during cleaning measured 5 m from ground level: EC: PowerPulse : Blower: ccessories Ladder/gangway: 70.0 db 70.4 db 78.8 db Ladder/gangway designed according to ISO/EN/IN /4 and available in several configurations. Ladder with gangway, front-mounted ladder with double gangway, front-mounted monitoring equipment for explosion membrane oor contacts: 2.3 (close-before-switch-contact) in accordance with EN50047, IP67 NC contact. B-36CT-ET EX T S VV 3,0-R Please state location of inlet and discharge including angle degrees when ordering. The explosion membrane for side venting is always located Sgr from the inlet 270 Inlet R/L Bag length Venting in roof Cone/scraper Total separator External compressed air Cleaning system B/EC No. of bags Blower filter/ec filter Blower-filter with scraper bottom and tangential inlet. Cross-section shows the PowerPulse cleaning system. Blower-filter with conical bottom and tangential inlet. Blower-filter with conical bottom and total separator.
3 Blower and EC-filters I/Ivfv 1 H1 350 E B Hs I/Ivfv 1 H1 K E B Hk I 1 +H1 K E d Ht B - scraper bottom B - conical bottom B - total separator ilter area Hs H1 Hk K Ht d I m² mm mm mm mm mm mm mm mm mm B-36 2,0 34, B-36 2,5 42, B-36 3,0 51, x B-36 3,5 59, x B-36 4,0 65, x B-36 4,5 74, x B-36 5,0 80, x B-60 2,0 57, B-60 2,5 71, B-60 3,0 85, B-60 3,5 99, B-60 4,0 108, B-60 4,5 123, B-60 5,0 133, B-84 3,0 119, B-84 3,5 139, B-84 4,0 152, B-84 4,5 172, B-84 5,0 186, B-90 3,0 128, B-90 3,5 149, B-90 4,0 163, B-90 4,5 185, B-90 5,0 0, B-36-60, 84/90 has one filter door in the top section and one in the filter top ( mm).
4 M 101 Top, conical and scraper d Bottom, total separator Std. top I s t J J ootplate ootplate ø o Bottom, scraper Bottom, conical VV top I VV Weight with Weight with Weight with I VV B E J O S T M conical bottom scraper bottom total separator mm mm mm mm mm mm mm mm kg kg kg
5 = t ~ Blower and EC filters Ca Ca=301 C C=475 C= ,5 ø18 t=5217 t H=4556 K=700 = d= dn 300 Ci=199 B-8/12/ EC K n 300 d d= =1469 V=3953 V H=4556 H K=700 K = C=475 Ø400 Ø374 =Ø900 H=4556 =1347 K=700 = Ø374 =Ø900 Type ilter area i x Bi H t V Ci Ca m 2 mm mm mm mm mm mm mm mm B-8-1,5-KT 5, B-8-2,0-KT 7, B-12-1,5-KT 8,7 Ø B-12-2,0-KT 11,5 =Ø B-12-2,5-KT 14, B-12-3,0-KT 17, B--2,0-KT 19, B--2,5-KT 23, B--3,0-KT 28, B--2,0-K 19, B--2,5-K 23, B--3,0-K 28, B--2,0-S 19, B--2,5-S 23, B--3,0-S 28, B-34-2,0-K 32,4 300x B-34-2,5-K 40,4 300x B-34-3,0-K 48,5 300x B-34-3,5-K 56,5 300x B-34-4,0-K 61,8 400x B-34-2,0-S 32,4 300x B-34-2,5-S 40,4 300x B-34-3,0-S 48,5 300x B-34-3,5-S 56,5 300x B-34-4,0-S 61,8 400x B-55-2,0-K 52,4 400x B-55-2,5-K 65,4 400x B-55-3,0-K 78,4 400x B-55-3,5-K 91,3 400x B-55-4,0-K 99,8 500x B-55-2,0-S 52,4 400x B-55-2,5-S 65,4 400x B-55-3,0-S 78,4 400x B-55-3,5-S 91,3 400x B-55-4,0-S 99,8 500x B--S Ca d = H Ci= =3025 T S N 165
6 ø13 C i o Bo C i o Bo 180 Bi N K T H V H V Bi S 350 B-34/55EC S Ci Ci B-34/55EC K Ø 400 C d o x Bo K N S x T Weight incl. mm mm mm mm mm mm mm mm mm bags kg x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
ATEX. Operating range kw, 15.6 min -1, 3 x 230 V, 50 Hz, 0.7 A 24 VDC.
Proucs for us hanling DusSorm filer The DusSorm filer is an uner- an over-pressure filer, esigne for coninuous operaion. Consruce as a self-supporing shee meal consrucion. The roun esign ensures grea srengh
More informationFMC cartridge filter. Compact cartridge filter for solving dust problems within a wide range of industries
Compact cartridge filter for solving dust problems within a wide range of industries The FMC cartridge filter series offers many operational benefits thanks to its compact design and patented UniClean
More informationFilter Fan Unit LIGHT
Filter Fan Unit LIGHT Type LIGHT EC Technical Concept Technical Concept Filter Fan Unit LIGHT Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air to individual
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type
More informationUPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo
UPGRADE PROGRAM V250 Series Pumps vs V301 Series Pumps Technical Memo INDEX Outline drawings ISO100 3 Outline Drawing CFF6 5 Technical Specification 7 Notes 8 Accessories 8 Controller comparison 9 Outline
More informationT EN TROVIS Electropneumatic Positioner
T 8484-1 EN TROVIS 3730-1 Electropneumatic Positioner Application Single-acting positioner for attachment to pneumatic globe and rotary valves. Self-calibrating, automatic adaptation to valve and actuator.
More informationAIR COOLED CONDENSERS
AIR COOLED CONDENSERS NQAC Quiet Line HNSQAC NQAC Quiet Line kw () Highly efficient external rotor fan motors give optimum performance with low noise levels Multiple fans (on all except smallest models)
More informationTechnical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC
Technical Concept Filter Fan Unit LIGHT Type LIGHT AC Type LIGHT EC Filter Fan Unit LIGHT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air
More informationUPGRADE PROGRAM. V70 Series Pumps vs V81T Series Pumps
VARIAN vacuum technologies UPGRADE PROGRAM V70 Series Pumps vs V81T Series Pumps Technical Memo Technical Memo - 1 - V70 series vs V81-T INDEX Outline drawings ISO63 3 Outline drawings CF2-¾ 4 Outline
More informationTechnical Concept. Tunnel Air Shower. All Types Air Shower / Air Locks
Technical Concept Tunnel Air Shower All Types Air Shower / Air Locks Tunnel Air Shower Technical Concept Product Description Personnel air showers minimize the transfer of dust particles on cleanroom clothing
More informationCable Entry Systems for Potentially Explosive Atmospheres
Cable Entry Systems for Potentially Explosive Atmospheres Directive 94/9/EC (ATEX) KEL-ER KVT 80 ATEX stands for ATmosphères EXplosives and is the short name for the European Directive 94/9/EC, regulating
More informationGTH. Rectangular double deflection grille QUICK FACTS
Rectangular double deflection grille QUICK FACTS For supply air Adjustable air deflectors Cleanable Installed using mounting frames FHB / FHA or commissioning box TRG Standard colour White RAL 900 -- alternative
More informationContinuous level measuring system NB 3000 Selection list
Table of contents Page Overview 2 ------------------------------------------------------------------------------------------------------------------- Specifications 3 -------------------------------------------------------------------------------------------------------------------
More informationFurnace Camera System Operator s Manual. Version
Furnace Camera System Operator s Manual Version 12-2010 Contents 1. Introduction... 2 2. Description... 2 2.1 Model Nomenclature... 2 2.2 Specifications... 3 2.3 Confirmation of Camera Field of View...
More informationEC centrifugal module - RadiPac
KG9-AS8- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More information/2 way indirect solenoid operated valves G 1/2, 1/2 NPT or flanged with NAMUR Interface
9805 / way indirect solenoid operated valves G /, / NPT or flanged with NMUR Interface Main application: single operated actuators for plants Valves for safety systems up to SIL (IE 6508) dd-on manual
More informationCentrifugal Fans direct driven. Issue 1
Centrifugal Fans direct driven ssue 1 1 Nicotra Gebhardt technologies like... utomated manufacture of compact scroll and impeller with forward curved blades Own C and Brushless-DC motor production for
More informationFloat Flow Meter. Flow measurement for translucent liquids and gases DN10 to DN65 mm. Technical data Orifice DN 10 to 65
Float Flow Meter Flow measurement for translucent liquids and gases DN10 to DN65 mm If a medium sufficient flow rate flows from bottom to top through a vertically inserted measuring tube, then the floated
More informationEC centrifugal module - RadiPac
KG9-AR- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 8 8- Fax +49 8 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type
More informationCable entry systems for potentially explosive atmospheres
Cable entry systems for potentially explosive atmospheres Directive 94/9/EC (ATEX) ATEX stands for ATmosphère Explosible and is the short name for the European Directive 94/9/EC, regulating the market
More informationFlow VA 500/
VA 500/ 520 Verbrauch 79 What are the advantages of the flow measuring technology of CS Instruments? 1) 500 is mounted by means of a standard 1/2 ball valve. During mounting and dismounting the safety
More informationSTR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions
STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA
More informationEC centrifugal module - RadiPac
KG8-AU6-B ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-746 Mulfingen Phone +49 798 8- Fax +49 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationDigital Positioner 8049
Compact digital positioner for pneumatic control valves. Positioner can be integrated into valve actuator (no external moving parts for stroke feedback) Wide range of strokes - 8 mm No steady-state air
More informationCFL: Air volume: Up to 8,200m³/h Vacuum: Up to 5,000Pa Filter area: m²
CFL filters Complete and space-saving Plug & Play compressed-air cleaned filter unit with integrated fan to be used for air filtration from processes that form limited dust volumes (welding, cutting, grinding
More informationData Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication
Data Sheet T 8493 EN Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,
More information98025 NAMUR 3/2 poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface
9805 NMUR / poppet valves electromagnetic actuated, indirectly controlled G /, / NPT or flanged with NMUR Interface Main application: single operated actuators for plants Valves for safety systems up to
More information09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD
Air-Cooled Condensers/Air-Cooled Fluid Coolers 09LD/GD 09GD 09LD/GD Nominal cooling capacity 281-987 kw The 09LD air-cooled condensers are designed for refrigeration plants where a halogenated hydrocarbon,
More informationIntelligent Transducers for Level Measurement
dbi Series Transducers Intelligent Transducers for Level Measurement Features Self-contained Solids or liquids applications HART or Profibus PA DATEM digital echo processing Various mounting options Standards-compliant
More informationOutput Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W
Differential Pressure Sensor (Air) Differential pressure transmitter with 8 selectable ranges 0 to 5/10 V, 4 to 20 ma outputs and Modbus functionality. NEMA 4X / IP65 rated enclosure. For monitoring the
More informationPreparation Units for Compressed Air. Modular construction Compact design Simple mounting Corrosion-resistant casings 1032 AL
L Preparation Units for ompressed ir Modular construction ompact design Simple mounting orrosion-resistant casings Maintenance devices for compressed air are put together according to need from the individual
More informationProduct data sheet : Electric height adjustable desk frame
Product data sheet : Electric height adjustable desk frame 501-27 327990.2 Table of contents Packing details.... 3 Main measures and specifications.... 4 Tabletop drillings.... 5 Assembly and use... 6
More informationVIREO Ceiling with ALX
Square ceiling air diffuser with nozzles for supply air, with plenum box QUICK FACTS Flush design Suitable for VAV-applications Fast and easy installation Sealing ring, standard for spigot Energy efficient
More informationStandard Frame Axial Fans
Quick reference guide Standard Frame Axial Fans 2007 Edition about Axair Fans UK Application knowledge : 20 years experience in air movement; from fume handling to refrigeration; from small electronic
More information42C/V. Fan Coil Unit Air Flow: 340~2040m 3 /h
2/V Fan oil Unit Air Flow: 0~0m 3 /h arrier hina arrier orporation is a subsidiary of the United Technologies orp. (UT), which ranks the 10th in Fortune Top 00 in and has its operations in aerospace and
More informationRadiator Valves. Building Technologies HVAC Products. NF norm, for 2-pipe heating systems
6 EN - Straight valves VDN Angle valves VEN Reverse angle valves VUN Radiator Valves NF norm, for -pipe heating systems VDN VEN VUN Valve bodies made of brass, mat nickel-plated DN, DN and DN (VDN, VEN
More informationEC axial fan - HyBlade
WG-HU- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D- Mulfingen Phone +9 9 - Fax +9 9 - info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59 General
More informationVariable Area Flowmeter DATASHEET
Variable Area Flowmeter DATASHEET JUNHO 0 Data sheet DS/A6/6EN Rev. I Models A600 & A600 Purgemaster SNAP-IN Small Flowmeter Long-term reliable performance flowmeters with low cost-of-ownership High strength
More informationFlow. Order number VA 550. Order no. VA 570. Further accessories A_...M_
Order number VA 550 housing High-pressure rig for VA 550 recoended for mounting from 10 to 100 bar Order no. 0695 0550 A_...M_ 0530 1155 Order no. VA 570 Order no. 0695 0570 0695 0571 0695 0572 0695 0573
More informationTechnical Concept. Filter Fan Unit RETURN AIR. Type RA-AC Type RA-EC
Technical Concept Filter Fan Unit RETURN AIR Type RA-AC Type RA-EC Filter Fan Unit RETURN AIR Technical Concept Product Description Technical Data M+W Products Filter Fan Units RETURN AIR (FFU-RA) are
More informationDMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9
Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers Calibration service companies and service industry Research and development laboratories National
More information24V, Motorized Actuators
24V, Motorized Actuators AMV 435, 3-point floating Description Main data: Supply voltage: 24 VAC/DC, 50 or 60 Hz Available control input signal versions: -3-point floating Stem travel: 20 mm Selectable
More informationStandardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.
Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG 9 1610 and 1700 Nl/min (1.636 and 1.728 Cv) Order code Series and function 1) Plug socket see page
More informationLevel limit switch Series RF 3000 Selection list. Overview 2
Table of content Overview 2 Page Applications 4 ------------------------------------------------------------------------------------------------------------- RF 3100 6 Standard version -------------------------------------------------------------------------------------------------------------
More informationThermal Mass Flowmeter Sensyflow FMT200-D
Data Sheet Thermal Mass Flowmeter Sensyflow FMT200-D Direct measurement of mass flow or standard volume flow of compressed air, nitrogen and biogas independent of media pressure and temperature Wide measuring
More informationF&J SPECIALTY PRODUCTS, INC.
F&J SPECIALTY PRODUCTS, INC. Digital Air Monitoring System Enzyme Dust Samplers F&J Models: DF-804DTE-30, DF-804DTE-30EC and DF-804DTE-30HT GENERAL DESCRIPTION: The DF-804E-30 series high volume enzyme
More informationPortable low-pressure controller Model CPC2000
Calibration technology Portable low-pressure controller Model CPC2000 WIKA data sheet CT 27.51 Applications Mobile calibration of low-pressure measuring instruments Supply of very low positive or negative
More informationPROFIBUS-PA Positioner Type 3785
PROFIBUS-PA Positioner Type 3785 Application Single-acting or double-acting PROFIBUS-PA positioner for attachment to pneumatic control valves. Rated travel from 7.5 to 120 mm Opening angle up to 120 Smart,
More informationANACONDA MULTIFLEX CONDUIT TYPE UI
ANACONDA MULTIFLEX CONDUIT TYPE UI Very robust, extremely flexible and corrosion resistant Multifl ex type UI is the stainless steel version of type UIG. Extremely fl exible and robust, this fully interlocked,
More informationEC centrifugal module - RadiPac
K3G-AP25-1 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone +49 7938 81- Fax +49 7938 81-11 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County
More informationG 1/2 30,5 A Brass NBR 0,8 3,
4/2 way poppet valves electromagnetic actuated, directly controlled /4 & /2 Working from 0 bar up Suitable for vacuum range down.33 0-2 mbar l/s Protection class : IP 65, Ex em, Ex d TEX approved (see
More informationThreaded thermocouple Miniature design Model TC10-D
Temperature Threaded thermocouple Miniature design Model TC10-D WIKA data sheet TE 65.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion technology
More informationBelt-driven fans fitted with electric motors and a standardised set of pulleys, belts and protectors in accordance with standard ISO
CMRS-X Belt-driven fans fitted with electric motors and a standardised set of pulleys, belts and protectors in accordance with standard ISO 13857. Fan: Sheet steel casing. Impeller with reaction blades
More informationPressure sensors SPAW with display
Key features At a glance 9 pressure ranges from 1 +1 bar up to 0 +100 bar 4-digit LED display, easy to read, robust Protection class IP67 320 rotatable display 1% accuracy, 0.15% repetition accuracy Temperature
More informationThreaded resistance thermometer Miniature design Model TR10-D
Temperature Threaded resistance thermometer Miniature design Model TR10-D WIKA data sheet TE 60.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion
More informationMotorised Butterfly Valve DMK Nominal Diameter Rp 3/4 - Rp 2
Motorised Butterfly Valve DMK Nominal Diameter Rp / - Rp.0 Printed in Germany Rösler Druck Edition 0.0 Nr. 9 77 Technical description The DUNGS DMK motorised butterfly valve is an actuator without zero
More informationFALCON High Flow. Circular ceiling air diffuser for supply air QUICK FACTS
Circular ceiling air diffuser for supply air QUICK FACTS Ceiling air diffuser for supply air in rooms with high ceiling Manual operated change of spread direction as standard Motor operated change of spread
More informationHigh-end pressure controller Model CPC8000
Calibration technology High-end pressure controller Model CPC8000 WIKA data sheet CT 28.01 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers Calibration
More information26360, 80207, 3/2, 5/2 & 5/3 Indirect solenoid actuated spool valves
66, 87, /, 5/ & 5/ > > Port size: G/ & G/ > > Compact design > > Easily interchangeable solenoid > > tandard manual override > > ll valves available with Ex protected coils (TEX or other international
More informationVane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing
Vane wheel probe BFA25 for flow measurement of gases and liquids with egrated, configurable transducer UFA in Ex-d housing Drawing 5 Vane wheel flow probe BFA25 (Dimensions see Page 3) Measurable variables
More informationDUCTED SPLIT SYSTEMS With Scroll compressors
DUCTED SPLIT SYSTEMS With Scroll compressors 2 Benefits TOTAL COMFORT ON WIDE AREAS The Ducted Blower Split Systems for light commercial applications of DXDXT-M/K series are the ideal solution for keeping
More informationEXPLOSION VENTING WITH STUVENT RUPTURE DISC
Background The pressure increase in process equipment caused by a dust/gas explosion can be controlled if a vent installed on the equipment is opened at the right moment. In order to reduce the risks for
More informationTeddIngTon AIR CURTAIN SYSTEMS. robuvent. The smart solution for industry. Fitted with the CORRIGO air discharge system DOORS MADE OFAIR
TeddIngTon AIR CURTAIN SYSTEMS robuvent The smart solution for industry Fitted with the CORRIGO air discharge system DOORS MADE OFAIR The smart energysaving solution. Industrial doors and workshop entrances
More informationSeries MAGNUS 21. Centrifuges and laboratory products. Tel.:
Centrifuges and laboratory products General applications: Centrifuges: Floor standing Series MAGNUS 21 12 Centrifuges: Floor standing: Series Magnus 21 Magnus 21 High capacity on a underfloor centrifuge
More informationPneumatic Control Unit for the integrated mounting on process valves
Pneumatic Control Unit for the integrated mounting on process valves Type 890 can be combined with Compact design Pilot valve with high air flow rate Internal control air channel Optical position indicator
More informationThe device is distinguished by low power consumption, a long service life and robust construction.
Data sheet LED 160 NAi For use as a 5 nautical mile beacon on offshore wind turbines Maintenance-free LED technology Standard NAi bus interface for power supply and communication Suitable for series connection
More informationThermocouples Model TC200, for Additional Thermowell
Electrical Temperature Measurement Thermocouples Model TC200, for Additional Thermowell WIKA Data Sheet TE 65.10 Applications T Machinery, plant and tank construction T Energy and power plant technology
More informationFlow Measurement SITRANS F US Inline
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More informationFlow Measurement SITRANS F US Inline
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More informationPressure switch Type KP
MAKING MODERN LIVING POSSIBLE Data sheet Pressure switch Type KP KP switchs are for use in refrigeration and air conditioning systems to give protection against excessively low suction or excessively high
More informationSeries P215DP Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)
PSC 0108 European Refrigeration Controls Catalogue Catalog Section 4 Product Bulletin Series Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression
More informationPhotoelectrics Diffuse-reflective Type PA18C.D..., DC
Photoelectrics Diffuse-reflective Type PA18C.D..., DC Miniature sensor range Range: 1 m (Axial), 0.8 m (Radial) Sensitivity adjustment by potentiometer Modulated, red light 625 nm Supply voltage: to 30
More informationEx emergency pull-wire switches Ex ZS 71
Features/Options: Ex zone 1 and 21 Metal enclosure 2 contacts Wire length up to 35 m Small design Release by push-button (VD) Available without unlocking mechanism (per EN 60947-5-1) Wire pull and breakage
More informationPhotoelectrics Retro-reflective, Polarized Type PA18C.P..., DC
Photoelectrics Retro-reflective, Polarized Type PA18C.P..., DC Miniature sensor range Range: 5 m (axial), 4 m (radial) Sensitivity adjustment by potentiometer Modulated, red light 625 nm Supply voltage:
More informationPhotoelectrics Retro-reflective Type PA18C.R..., DC
Photoelectrics Retro-reflective Type PA18C.R..., DC Miniature sensor range Range: 6.5 m (Axial), 5 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to
More informationDCV-SP DCV-SP. DCV-SP Pressure control SPL Version B03 with actuator DA4/8 SMART DAMPERS & MEASURING UNITS. Product description AIN DIN AOUT DCV-SP
DCV-SP Pressure control 24VAC + Communication DIN 24VAC + Communication AIN DCV-SP SMART DAMPERS & MEASURING UNITS Pressure control DCV-SP AOUT RELAY 1(14) Contents Page DCV-SP Introduction... 3 Functional
More informationMAJOR VA Power Inverter
MAJOR500-500 VA Power Inverter The Major500 is a highly reliable, telecom quality, DC to AC power inverter. The Major500 features full electronic protection, high efficiency and low output noise. The built-in
More informationHP-HC series safety hinge switches
HP-HC series safety hinge switches escription Pizzato Elettrica extends its range of products by creating the new HP-HC series safety hinge switches where safety and style blend into a single product.
More informationHigh-speed peumatic pressure controller Model CPC3000
Calibration technology High-speed peumatic pressure controller Model CPC3000 WIKA data sheet CT 27.55 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers
More informationInstallation Instructions
50ES, 50EZ, 50GL, 50GS, 50GX, 50JS, 50JX, 50JZ, 50SD, 50SZ, 50VL, 50VT, 50XP, 50XZ 601A, 602A, 602B, 604A, 604B, 604D, 607C, 701A, 702A, 702B, 704A, 704B, 704D, 707C PA1P, PA2P, PA3P, PH1P, PH2P, PH3P
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on araday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationJUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet
sales@jumo.co.uk info.us@jumo.net Page 1/9 JUMO PINOS L01 Calorimetric flow sensor Brief description The JUMO PINOS L01 flow sensor serves the measuring and monitoring of flow velocities of water and aqueous
More informationSeries 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication
Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic on/off valves in safety-instrumented systems.
More informationX=2000 Z=2000 X=2000 Z=1600. E0/E150 in µm L/ L/ L/ L/ L/ L/400. R0 in µm
ZEISS MMZ M Specifications Version: November 2017 System description Type according to ISO 10360-1:2000 Moving bridge CMM Operating mode motorized / CNC Sensor mounts Fixed installation of ZEISS VAST gold
More informationLevel Measurement Continuous level measurement - Ultrasonic transmitters
Overview Configuration is a short-range integrated ultrasonic level transmitter. It is intrinsically safe (ATEX, CSA, FM, IECEx, NEPSI), 2 wire, to 20 ma loop powered, ideal for liquids, slurries, and
More information6215L Inline & NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve
L Inline & NMUR series, / & / > Port size: / (ISO /NPT) or flanged with NMUR interface > Suited for outdoor use under critical environment conditions (see solenoid list) > Variable valve solenoid combination
More informationNEOSTAR AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE HFC. 18 > 1240 kw. NEOSTAR POWER The choice of performance and low space requirement.
AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE Hard Discount - Supermarkets - Hypermarkets Refrigerated storage and transit stocking - Dispatch centres Food processing - Canteen kitchens HFC 18 >
More informationMark like a Professional. Table marking system NetMarker
Mark like a Professional Table marking system NetMarker Mark like a Professional NetMarker The compact table marking system The innovative, network-compatible CNC table marking system NetMarker excels
More informationSCVA08, SCVA10, SCVA20 & SCVA32, 3/2 Solenoid actuated safety valve
SCV0, SCV0, SCV & SCV, / > > Port size: /4, /, /4 and (ISO G, NPT) > > Range of sizes - DN, 0, and > > Redundant valve assembly, pneumatic self monitoring with integrated safety silencer > > Ensures safe
More informationStandard Construction. Options and Accessories
SP, SP-L, SP 22 ath and Inline ans SP SP UL/cUL 507-599 - eiling xhaust ans SP-90 and smaller and SP- are UL/cUL Listed for above bathtub/shower with I branch protected circuit. SP- is UL/cUL Listed UL/cUL
More informationLevel Measurement Continuous level measurement - Ultrasonic transmitters
Overview Configuration is a short-range integrated ultrasonic level transmitter. This general purpose, 2-wire, to 20 ma loop powered transmitter is ideal for liquids, slurries, and bulk materials in open
More informationThermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches.
Data sheet Thermostat KP The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches. They can be connected directly to a single-phase AC motor of up to approx. 2 kw or
More informationActuator LA31. Data sheet LINAK.COM/DESKLINE
Actuator LA31 Data sheet LINAK.COM/DESKLINE LA31 The LA31 actuator is a very quiet and powerful linear actuator desigend for a variety of desk applications ranging from kitchen applications to industrial
More information80265 series, 3/2 Indirect solenoid actuated poppet valve
> > Port size: G/... G > > High flow rate > > Optionally air pilot operated > > High repeatability of switching time > > Variable valve solenoid combination Technical features Medium: Compressed air, filtered,
More informationALFRESCO SERIES RESIDENTIAL WEATHER RATED TV ENCLOSURES PRODUCT OVERVIEW. Specifications and Detailed Product Overview
RESIDENTIAL WEATHER RATED TV ENCLOSURES PRODUCT OVERVIEW Specifications and Detailed Product Overview WEATHER RATED TV ENCLOSURES Designed and engineered in Australia, to suit our tough environmental conditions,
More informationTemperature probes 468 Hans Turck GmbH & Co. KG Tel Fax Edition I/
468 Hans Turck GmbH & Co. KG Tel. +49 208 49 52-0 Fax +49 208 49 52-264 Temperature probe a Temperature probes TP series TP series Highest possible flexibility A temperature probe has to be flexible and
More informationNEXPTZ364P(N)A HIGH-SPEED EXPLOSION-PROOF PTZ FEATURES.
Honeywell NEXPTZ364P(N)A is a high-speed explosion-proof camera that follows stringent explosion-proof requirements with creative mechanical strength and design. It withstands even the most demanding conditions,
More informationSINGLE. Technical Data Book. Big Duct for EU (R410A, 50Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU
SINGLE Technical Data Book Big Duct for EU (R4A, 0Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU History Version Modification Date Remark Ver 1.0 Release SINGLE Big Duct for EU (R4A, 0Hz, HP)
More information