1 PNSPO!!!!!! NB-series Programmable Terminals SETUP MANUAL Cat.No. V107-E1-01

2 Notice DANGER WARNING Caution OMRON Product References OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to heed precautions can result in injury to people or damage to property. Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Additionally, there may be severe property damage. Indicates a potentially hazardous situation which, if not avoided, will result in death or serious injury. Additionally, there may be severe property damage. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury, or property damage. All OMRON products are capitalized in this manual. The word Unit is also capitalized when it refers to an OMRON product, regardless of whether or not it appears in the proper name of the product. The abbreviation Ch, which appears in some displays and on some OMRON products, often means word and is abbreviated Wd in documentation in this sense. The abbreviation PLC means Programmable Controller. The abbreviation host means a controller, such as an IBM PC/AT or compatible computer, that controls a PT (Programmable Terminal). Visual Aids The following headings appear in the left column of the manual to help you locate different types of information. Note Indicates information of particular interest for efficient and convenient operation of the product. Reference Indicates supplementary information on related topics that may be of interest to the users. 1,2, Indicates lists of one sort or another, such as procedures, checklists, etc. CS1G-CPU -V1 Boxes in model numbers indicate variable characters. For example: CS1G-CPU -EV1 indicates the following models: CS1G-CPU42-EV1, CS1G-CPU43-EV1, CS1G-CPU44-EV1 and CS1G-CPU45-EV1. OMRON,2011 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of OMRON. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication. 1

3 Contents Notice... 1 About this Manual... 5 Related Manuals... 6 Terminology... 7 Introduction... 8 Safety Precautions... 9 Precautions for Safe Use...11 Precautions for Correct Use Conformance to EC Directives Read and Understand this Manual Section 1 Part Names and Functions Part Names Part Names Part Specifications Section 2 Installing the NB Unit and Connecting Peripheral Devices Installing the NB Unit Installation environment Installation onto the Operation Panel Connecting the Power Supply Grounding Wiring Start of NB Series Connection to NB-Designer Connecting by RS-232C Connecting by USB Communication Connections Host Link Connection Method Connecting more than one PLC

4 2-4-3 Settings for each Unit Section 3 System Setting Mode The display method of System Setting Mode Functions of System Setting Mode Section 4 Calibrate Mode The display method of Calibrate Mode Functions of Calibrate Mode On-line Touch-control Calibration Function Section 5 Maintenance and Troubleshooting Maintenance Troubleshooting Software Trouble Communication-related Troubles Hardware Troubles Other Troubles Request to change the NB Unit Appendices Appendix-1 Specifications Appendix-1-1 General Specifications Appendix-1-2 Performance Specifications Appendix-1-3 Communication Specifications Appendix-2 External Dimensions Appendix-3 RS-422A/485 Connections Appendix-3-1 Grounding and Shielding of the Cables Appendix-4 Fabrication of the Connection Cable Appendix-4-1 Cable Processing Appendix-4-2 Soldering Appendix-4-3 Shield Assembly Appendix-4-4 Method for fabricating the cable for connection to OMRON PLC

5 Appendix-4-5 Method for fabricating the cable for connection to PC Appendix-5 List of Models Appendix-6 List of Options

6 About this Manual Section 1 Part Names and Functions This section describes the names and functions of the various parts of an NB Unit. Section 2 Installing the NB Unit and Connecting Peripheral Devices This section describes the methods used to install the NB Unit and connect peripheral devices. Section 3 System Setting Mode This section describes the System Setting Mode. Section 4 Calibrate Mode This section describes the Calibrate Mode. Section 5 Maintenance and Troubleshooting This section describes the maintenance and inspection methods for preventing errors occurring, and troubleshooting measures when errors occur. WARNING Failure to read and understand the information provided in this manual may result in personal injury or death, damage to the product, or product failure. Please read each section in its entirety and be sure you understand the information provided in the section and related sections before attempting any of the procedures or operations given. 5

7 Related Manuals The related manuals are as follows: Devices and Software Manual name NB Series NB Series NB-Designer Operation Manual NB Series Setup Manual (This manual) NB Series Host Connection Manual NB Series Startup Guide PLC SYSMAC CP Series CP1L CPU Unit Operation Manual SYSMAC CP Series CP1H/L CPU Unit Programming Manual SYSMAC CP Series CP1H CPU Unit Operation Manual SYSMAC CP Series CP1E CPU Unit Hardware USER'S Manual SYSMAC CP Series CP1E CPU Unit Software USER'S Manual SYSMAC C200HX/HG/HE(-E/-ZE) Installation Guide SYSMAC C200HX/HG/HE Operation Manual SYSMAC C200HX/HG/HE(-ZE) Operation Manual SYSMAC CQM1H Operation Manual SYSMAC CPM1A Operation Manual SYSMAC CPM2A Operation Manual SYSMAC CPM1/CPM1A/CPM2A/CPM2C/SRM1(-V2) Programming Manual SYSMAC CPM2C Operation Manual SYSMAC CS1 Series CS1G/H Operation Manual SYSMAC CS/CJ Series Serial Communications Boards and Serial Communications Units Operation Manual SYSMAC CJ Series CJ1G/H(-H) CJ1M CJ1G Operation Manual SYSMAC CS/CJ Series Programming Manual SYSMAC CS/CJ Series INSTRUCTIONS Reference Manual SYSMAC CS/CJ Series Programming Consoles Operation Manual SYSMAC CS/CJ Series Communications Commands Reference Manual SYSMAC CJ Series CJ2 CPU Unit Hardware USER'S Manual SYSMAC CJ Series CJ2 CPU Unit Software USER'S Manual External Tool CX-Programmer Ver.9. Operation Manual Manual No. V106 V107 V108 V109 W462 W451 W450 W479 W480 W302 W303 W322 W363 W317 W352 W353 W356 W339 W336 W393 W394 W340 W314 W342 W472 W473 W446 6

8 Terminology The following terminology is used in this manual. About the terminology NB Unit NB Series PLC CP Series CS/CJ Series C Series Serial Communication Unit Serial Communication Board Communication Board CPU Unit NB-Designer Host PT HMI Indicates the main Unit of the products in the OMRON NB Series of Programmable Terminal. Indicates products in the OMRON NB Series of Programmable Terminal. In this manual, unless otherwise specified, NB Series is taken as the subject concerned. Indicates a Programmable Controller in the OMRON CP, CS/CJ, or SYSMAC C Series of Programmable Controllers. Indicates the following products in the OMRON CP Series of Programmable Controllers: CP1H CP1L CP1E Indicates the following products in the OMRON CS/CJ Series of Programmable Controllers: CS1G CS1H CS1G-H CS1H-H CJ1G CJ1M CJ2M CJ2H Indicates the following products in the OMRON C Series of Programmable Controllers: C200HX (-Z) C200HG (-Z) C200HE (-Z) CQM1 CQM1H CPM1A CPM2A CPM2C Indicates a Serial Communication Unit for an OMRON SYSMAC CS/CJ-Series PLC. Indicates a Serial Communication Board for an OMRON SYSMAC CS/CJ-Series or CQM1H PLC. Indicates a Communication Board for an OMRON C200HX/HG/HE (-Z) PLC. Indicates a CPU Unit in the OMRON CP, CS/CJ or SYSMAC C Series of Programmable Controllers. Indicates the OMRON NB-Designer. Indicates the PLC and other units functioning as the control devices for NB-Series Units. Indicates an OMRON Programmable Terminal. Indicates an OMRON Programmable Terminal. 7

9 Introduction Intended Audience This manual is intended for the following personnel, who must also have knowledge of electrical systems (an electrical engineer or the equivalent). Personnel in charge of introducing FA systems into production facilities. Personnel in charge of designing FA systems. Personnel in charge of installing and connecting FA facilities. Personnel in charge of managing FA systems and facilities. General Precautions The user must operate the product according to the performance specifications described in the operation manuals. Do not use the PT touch switch input functions for applications where danger to human life or serious property damage is possible, or for emergency switch applications. Before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems, machines and equipment that may have a serious influence on lives and property if used improperly, consult your OMRON representative. Make sure that the ratings and performance characteristics of the product are sufficient for the systems, machines, and equipment, and be sure to provide the systems, machines, and equipment with double safety mechanisms. This manual provides information for connecting and setting up an NB-series PT. Be sure to read this manual before attempting to use the PT and keep this manual close at hand for reference during installation and operation. 8

10 Safety Precautions Notation Used for Safety Information The following notation is used in this manual to provide precautions required to ensure safe usage of the product. The safety precautions that are provided are extremely important to safety. Always read and heed the information provided in all safety precautions. The following notation is used. Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. Additionally there may be severe property damage. Precautions for Safe Use Indicates the points that should be practiced or avoided for safe usage of the products. Precautions for Correct Use Indicates the points that should be practiced or avoided in order to prevent the product from failure to function, malfunctions or negative impacts on its performance and functionality. Symbols Prohibition Indicates a general prohibition. Disassembling prohibition Any attempts to disassemble the product may result in electric shock or other injuries. DO NOT DISASSEMBLE! Caution Indicates general cautionary, warning, or danger level information. 9

11 Warning notation Do not attempt to take the product apart and do not touch the product inside while the power is being supplied. Otherwise it may result in electric shock. Do not touch any internal parts while the power is being supplied. Otherwise it may result in electric shock. Always ensure that the personnel in charge confirm that installation, inspection, and maintenance were properly performed for the NB Unit. Personnel in charge refers to individuals qualified and responsible for ensuring safety during machine design, installation, operation, maintenance, and disposal. Ensure that installation and post-installation checks are performed by personnel in charge who possess a thorough understanding of the machinery to be installed Do not use the input functions of the touch switch, etc. of the NB Unit, in applications that involve human life, in applications that may result in serious injury, or for emergency stop switches. Do not attempt to disassemble, repair, or modify the NB Unit. Otherwise it may impair the safety functions. Never press more than two points on the touch panel of the NB Unit at a time. Otherwise, it may activate a switch somewhere between the two points. 10

12 Precautions for Safe Use When unpacking the NB Units, check carefully for any external scratches or other damage. Also, shake the Units gently and check for any abnormal sound. The NB Unit must be installed in a control panel. The mounting panel must be between 1.6 and 4.8 mm thick. Tighten the Mounting Brackets evenly to a torque of between 0.5 and 0.6 N m to maintain water and dust resistance. If the tightening torque exceeds the specified value, or the tightening is not even, deformation of the front panel may occur. What is more, make sure the panel is not dirty or warped and that it is strong enough to hold the Units. Do not let metal particles enter the Units when preparing the panel. Do not connect an AC power supply to the DC power terminals. Use a DC power with a slight voltage fluctuation and that will provide a stable output even if the input is momentarily interrupted for 10 ms. Rated Power Supply Voltage: DC 24 V (Allowable range DC 20.4~27.6 V) Do not perform a dielectric voltage test. Making the connection by using terminal screws crimping on a twisted-pair cable with a crimping range of 12~26 AWG, and only 6.5 mm of insulation peel of the cable needs to be peeled off. Tighten the terminal screws to a torque of between 0.3 and 0.5 N m. Make sure the screws are properly tightened. To prevent malfunctions caused by noise, ground the Unit correctly. Do not touch the packaging part of the circuit board with your bare hands. Discharge any static electricity from your body before handling the board. When using the No. 6 pin of the serial communication port COM1 connector for a voltage of DC+5V, make sure the supply equipment's current capacity is below 250mA before using it. The DC+5V voltage output of the NB Unit is +5V±5%, and the maximum current is 250mA. Turn OFF the power supply before connecting or disconnecting cables. Always keep the connector screws firmly tightened after the communication cable is connected. The maximum tensile load for cables is 30 N. Do not apply loads greater than this. Confirm the safety of the system before turning ON or OFF the power supply, or pressing the reset button. The whole system may stop depending on how the power supply is turned ON or OFF. Turn ON/OFF the power supply according to the specified procedure. Reset by pressing the reset button, or restart the power supply, once the DIP switch settings are changed. To ensure the system s safety, make sure to incorporate a program that can confirm the normal functionality of the NB Unit before running the system. Start actual system application only after sufficiently checking screen data, macros and the operation of the program at the host side. Don t press the touch panel with a force greater than 30 N. Do not use a screwdriver or any other tool to press the touch panel. Confirm the safety of the system before pressing the touch panel. Signals from the touch switches may not be input if the touch switches are pressed consecutively at high speed. Confirm that the PT has detected the input of a touch switch before pressing any other touch switch. Do not accidentally press the touch panel when the backlight is not lit or when the display does not appear. Make sure of the safety of the system before pressing the touch panel. 11

13 To use numeric input functions safely, always make maximum and minimum limit set- tings. Before initializing screen data, confirm that existing data is backed up at the NB-Designer. When changing the password with the system menu, do not reset or turn OFF the power supply until writing is finished. Failure to save the password may cause the screen to fail to function. When using an equipment monitor, confirm the safety of the system before carrying out the following operations: Changing monitor data; Changing operation mode; forced setup/reset; Changing the current value or the set value; Do not connect a USB connector to any device that is not applicable. Before connecting a USB connector to a device, make sure that the device is free of damage. Commercially available and the recommended USB HUBs are different from the general specifications of the NB Unit. The Unit may not function well in an environment subject to noise, static electricity. Therefore, when using a USB HUB, employ sufficient noise and static electricity insulation measures, or install it at a site free of noise or static electricity. While downloading or uploading screen data or system programs, do not perform the following operations that may corrupt the screen data or the system program: Turning OFF the power supply of the NB Unit. Pressing the PT s reset switch. Dispose of the Units and batteries according to local ordinances as they apply. When exporting products with lithium primary batteries containing perchlorate at 6ppb or above to or delivering them through California, USA, the following precautionary measures have to be publicized. Perchlorate material applicable through special processing. Refer to NB-Series products contain lithium primary batteries. When exporting products containing this kind of batteries to or delivering them through California, USA, label all the product packages as well as the appropriate delivery packages. Do not use benzene, paint thinner, or other volatile solvents, and do not use chemically treated cloths. Do not dispose the Units together with general waste at waste yards. When disposing them, follow the related local ordinances or rules. Customers may not replace the backlight lamp inside the NB Unit. Please contact OMRON s customer service center. Deterioration over time can cause the touch points to move. Calibrate the touch panel periodically. Water and oil resistance will be lost if the front sheet is torn or is peeling off. Do not use the Unit, if the front sheet is torn or is peeling off. The rubber packing will deteriorate, shrink, or harden depending on the operating environment. Inspect and replace the rubber packing periodically. The communication cables of the COM1 and COM2 connectors are not interchangeable. Confirm the pins of the ports before carrying out communications. Periodically check the installation conditions in applications where the PT is subject to contact with oil or water. 12

14 Precautions for Correct Use Do not install the Unit in any of the following locations: Locations subject to severe changes in temperature Locations subject to temperatures or humidity outside the range specified in the specifications Locations subject to condensation as the result of high humidity Locations subject to corrosive or flammable gases Locations subject to strong shock or vibration Locations outdoors subject to direct wind and rain Locations subject to strong ultraviolet light Locations subject to dust Locations subject to direct sunlight Locations subject to splashing oil or chemicals Take appropriate and sufficient countermeasures when installing systems in the following locations: Locations subject to static electricity or other forms of noise Locations subject to strong electric field or magnetic field Locations close to power supply lines Locations subject to possible exposure to radioactivity 13

15 Conformance to EC Directives NB-series Programmable Terminals are EMC compliant. 1 Concepts OMRON products are electronic devices that are incorporated in machines and manufacturing installations. OMRON PTs conform to the related EMC Directives (see note) so that the devices and machines into which they are built can more easily conform to EMC Directives. The actual products have been through inspections and are completely in accordance with EMC directives. However, when they are built into customers' systems, whether the systems also comply with these Directives is up to the customers for further inspection. EMC-related performance of OMRON PTs will vary depending on the configuration, wiring, and other conditions of the OMRON equipment or control panel. The customer must, therefore, perform final checks to confirm that the overall machine or device conforms to EMC standards. Note The applicable EMC (Electromagnetic Compatibility) standards are as follows: EMS (Electromagnetic sensitivity): EN : 2007 EMI (Electromagnetic Interference): EN : Conformance to EC Directives NB-series Programmable Terminals are EC compliant. Heed the following precautions in order to ensure that the customer s overall machine and device conform to EC Directives. 1. The PT must be installed in a control panel. 2. You must use reinforced insulation or double insulation for the DC power supply and the DC power supply must have minimal voltage fluctuations and provide a stable output even if the power supply input is interrupted for 10 ms. 3. The PTs conform to the standard EN , but radiated emission characteristics (10m regulations) may vary depending on the configuration of the control panel used, other devices connected to the control panel, wiring, and other conditions. You must therefore confirm that the overall machine or equipment complies with EC Directives. 4. This is a Class A product (Product for industry purpose). It may cause radio interference in residential areas, in which case the user may be required to take adequate measures to reduce interference. 14

16 Read and Understand this Manual Please read and understand this manual before using the product. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability Warranty OMRON'S EXCLUSIVE WARRANTY IS THAT THE PRODUCTS ARE FREE FROM DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR (OR OTHER PERIOD IF SPECIFIED) FROM DATE OF SALE BY OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON- INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. Limitations of Liability OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. IN NO EVENT SHALL THE RESPONSIBILITY OF OMRON FOR ANY ACT EXCEED THE INDIVIDUAL PRICE OF THE PRODUCT ON WHICH LIABILITY IS ASSERTED. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. 15

17 Application Consideration SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this manual. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. 16

18 Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this manual is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this manual has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors, or omissions. 17

19 Section 1 Part Names and Functions This section describes the names and functions of the various parts of an NB Unit. 1-1 Part Names Part Specifications

20 1-1 Part Names NB5Q-TW00B model Front view Back view When turning ON or OFF the power supply, confirm the safety of the system before operation. 19

21 NB7W-TW00B model Front view Back view When turning ON or OFF the power supply, confirm the safety of the system before operation. 20

22 1-2 Part Specifications Touch Panel Input operation can be carried out by means of the touch panel. By pressing the touch panel, the screens can be switched, and the contact information can be transmitted to the host. Don t press a touch switch with a force greater than 30N. Do not accidentally press the touch panel when the backlight is not lit or when the display does not appear. Confirm the safety of the system before pressing the touch panel. Do not use a screwdriver or any other tool to press the touch panel. Signals from the touch switches may not be input if the switches are pressed consecutively at high speed. Confirm each input before proceeding to the next one. Deterioration over time can cause the touch points to move. Calibrate the touch panel periodically. Serial Port COM1 Take the NB5Q-TW00B and NB7W-TW00B products as examples here. COM1 is a 9-pin D-type socket port. This port supports RS-232C communication function, making it connectable to a controller which features RS-232C function, and it can also be used for downloading programs or debugging for the product. The pins are defined as follows: Pins Signals I/O Functions 1 NC SD O Sending data 3 RD I Receiving data 4 RS(RTS) O Request to send* 5 CS(CTS) I Clear to send* 6 DC+5V - DC+5V output (with a maximum of 250mA) 7 NC NC SG - Signal ground * Pins 4 and 5 of NB5Q-TW00B and NB7W-TW00B are not used, thus not compliant with RS or CS functions. 21

23 When using the No. 6 pin of the serial communications port COM1 connector for a voltage of DC+5V, make sure the supply equipment's current capacity is below 250 ma before using it. The DC+5V voltage output of the NB Unit is +5V±5%, and the maximum current is 250 ma. Serial Port COM2 Take the NB5Q-TW00B and NB7W-TW00B as examples here. COM2 is a 9-pin D-type socket port. This port supports RS-232C/RS-485/RS-422A communication function. The pins are defined as follows: DIP Switch Pins Signals I/O Functions RS-232C RS-485 RS-422A 1 SDB+ I/O - - Sending data(+) 2 SD O Sending data RD I Receiving data Terminal R1 - - Terminal resistor 1 5 Terminal R2 - - Terminal resistor 2 6 RDB+ I/O - Send/ Receiving Receive data(+) data(+) 7 SDA- I/O - - Send/ 8 RDA- I/O - Receive data(-) 9 SG - Signal ground SW1 SW2 Operating modes ON ON System Setting Mode OFF ON Calibrate Mode ON OFF Downloader Mode OFF OFF User Project Mode Sending data(-) Receiving data(-) System Setting Mode: The PT will be launched into a built-in system setup screen, and is subject to the user for brightness, system time and buzzer settings. Calibrate Mode: When the user touches the panel, a symbol + will pop up on the screen, with which the touch control precision level can be calibrated. Downloader Mode: This is used for basic operations such as updating the firmware, downloading and uploading the user s engineering documents, etc. and this mode is not intended for general users. User Project Mode: This is the User Project Mode of NB-Series PTs. The PT will display the startup screen of the project already downloaded. Reset Switch When pressing the switch located on the back side of the PT, the system will be rebooted. 22

24 Section 2 Installing the NB Unit and Connecting Peripheral Devices This section describes the methods used to install the NB Unit and connect peripheral devices. 2-1 Installing the NB Unit Start of NB Series Connection to NB-Designer Communication Connections

25 2-1 Installing the NB Unit This section describes the methods used to mount the NB Unit onto an operation panel and connect the power supply Installation environment When mounting the NB Unit onto the operation panel, pay attention to the following precautions. Always ensure that the personnel in charge confirm that installation, inspection, and maintenance were properly performed for the NB Unit. "Personnel in charge" refers to individuals qualified and responsible for ensuring safety during machine design, installation, operation, maintenance, and disposal. Ensure that installation and post-installation checks are performed by personnel in charge who possess a thorough understanding of the machinery to be installed. Do not install the product in any of the following locations: Locations subject to rapid changes in temperature Locations subject to temperatures or humidity outside the range specified in the specifications Locations subject to condensation as the result of high humidity Locations subject to corrosive or flammable gases Locations subject to strong shock or vibration Locations outdoors subject to direct wind and rain Locations subject to strong ultraviolet light Locations subject to dust Locations subject to direct sunlight Locations subject to splashing oil or chemicals Take appropriate and sufficient countermeasures when the product is used in the following locations: Locations subject to static electricity or other forms of noise Locations subject to strong electric field or magnetic field Locations close to power supply lines Locations subject to possible exposure to radioactivity When unpacking the Units, check carefully for any external scratches or other damage. Also, shake the Units gently and check for any abnormal sound. 24

26 2-1-2 Installation onto the Operation Panel Install the NB Unit by embedding it into the operation panel. Use the metal kit and tool (a crosshead screwdriver) supplied with the Unit for installation. Proceed the installation following the procedures below. 1. Slot the panel with dimensions shown below, and fit the NB Unit into the panel from the front side. Models Opening Dimension (W H mm) NB5Q-TW00B 172.4(+0.5/-0) 131.0(+0.5/-0) NB7W-TW00B 191.0(+0.5/-0) 137.0(+0.5/-0) 2. As follows, insert panel fixators at the four locations on the top and bottom from the back of the NB Unit. Insert the hooks of positioners into the square holes on the Unit to hold the fixators properly, and tighten the screws firmly with the screwdriver. When operating on the operation panel, make sure to keep metal particles from entering the Unit. The mounting panel must be between 1.6 and 4.8 mm thick. The NB Unit must be installed in a control panel. For the sake of waterproof and dustproof, all the fixators must be evenly tightened to a torque of 0.5~0.6 N m. If the tightening torque exceeds the specified value, or the tightening is not even, deformation of the front panel may occur. Make sure that the operation panel is clean, unbent, and strong enough for the installation process. 25

27 2-1-3 Connecting the Power Supply Charge the power input terminals with a DC 24V power supply. Do not connect an AC power supply to the DC power terminals. Use a DC power supply with a minimal voltage fluctuations. Use a DC power supply that provides a stable output (even if the power supply input is interrupted for 10 ms) with reinforced insulation or double insulation. Power Supply The connectable power supply specifications are as follows: figure out a suitable power supply specification so as to satisfy the requirement for power supply capacity. Models Rated Voltage Allowable Voltage Range Power NB5Q-TW00B DC24V DC 20.4~27.6V 6W NB7W-TW00B DC24V DC 20.4~27.6V 7W Connect using terminal screws crimping on a twisted-pair cable with a crimping range of 12~26AWG, and only 6.5mm of insulation peel of the cable needs to be peeled off. Tighten the terminal screws to a torque of between 0.3 and 0.5 N m. Make sure the screws are properly tightened. 26

28 2-1-4 Grounding Wiring The NB Unit has a functional grounding terminal ( ). Arrange the wiring according to the following conditions. 1. When a potential difference occurs between the NB Unit and the host, arrange the grounding as illustrated. If the distance is too long to realize a single-point grounding, do not ground the NB Unit. 2. When the NB Unit, and noise source equipment such as motors and inverters, etc. are installed on the same panel, do not ground the of the NB Unit. of the To prevent malfunctions caused by noise, ground the Unit correctly. 27

29 2-2 Start of NB Series Confirm the hardware are all correctly connected, turn on the power supply, and start the NB-Series. This part describes the operations of the NB Series when it starts. When starting the NB Unit for the first time 1 Confirm that the DIP switches SW1 and SW2 on the back side are both ON. 2 Turn on the power supply of the NB Unit, and with the POWER LED on the front side turning green, the NB Unit starts, entering into the System Setting Mode. 3 Through the System Setup screen, the system time, starting window No., screen saving time, buzzer and the screen brightness can be set. When the setup is finished, turn OFF the power supply, turn OFF both of the DIP switches, SW1 and SW2, and then switch on the power supply again. When starting the NB Unit after downloading the screen data to it. 1 Confirm that the DIP switches SW1 and SW2 on the back side are both OFF. 2 Turn on the power supply of the NB Unit, and with the POWER LED on the front side turning green, the NB Unit starts. 3 The starting screen of the screen data downloaded to the NB Unit will be shown. Entering into Calibrate Mode 1 Confirm that the DIP switches SW1 and SW2 on the back side are respectively OFF and ON. 2 Turn on the power supply of the NB Unit, and with the POWER LED on the front side turning green, the NB Unit starts. 3 When the user touches the panel, a symbol + will pop up on the screen, with which the touch control precision level can be calibrated. When turning ON or OFF the power supply, confirm the safety of the system before operation. 28

30 2-3 Connection to NB-Designer In order to transmit the screen data established by the NB-Designer to the NB Unit, the NB Unit needs to be connected to a PC with a RS-232C or USB cable Connecting by RS-232C Connect the RS-232C cable at the PC side to the serial port COM1 of the NB Unit. Communication conditions Select the downloader mode through the tool menu of the NB-Designer. For details, refer to the NB-Designer User Manual [3-15 Download]. Communication cable Users can make connection cables by themselves. For details, refer to [Appendix-4 Fabrication of the Connection Cable] Connecting by USB Connect the USB port at the PC side and the USB slave connector of the NB Unit. As to the USB connection, there are some preparations and restrictions that need to be done or heeded. Refer to the following content to ensure a correct connection. 29

31 USB driver for the NB-Designer A USB driver needs to be installed in the PC for the purpose of transmitting screen data through USB. The USB driver will be automatically installed at the first time when connecting the NB Unit to a PC. Market available and the recommended USB HUBs are different from the general specifications of the NB Unit. The Unit may not function well in an environment subject to noise, static electricity. Therefore, when using a USB HUB, employ sufficient noise and static electricity insulation measures, or install it at a site free of noise or static electricity. Do not connect a USB connector to any device that is not applicable. Before connecting a USB connector to a device, make sure that the device is free of damage. Market available USB cables can be used to carry out the connection. Use a cable with a maximum length of 5m. 30

32 2-4 Communication Connections Host Link Connection Method Host Link is a connection method in which one PLC is connected to one NB Unit. There are 2 kinds of connection methods: RS-232C and RS-422A. The RS-232C connection method using serial ports COM1/COM2 This is the simplest and most feasible method. The following cables are recommended. XW2Z-200T (Cable length: 2m) by OMRON XW2Z-500T (Cable length: 5m) by OMRON The RS-422A connection method using the serial port COM2. With this method, the communication distance can be extended to a maximum of 500m. Connectable Units at the host side When using OMRON PLCs, the Units with built-in Host Link function vary depending on models and series. There is also the CPU Unit connected in a Host Link method through adding the serial communication board or communication board. When connecting, confirm the connected PLC's series, model and the models of the installed circuit board/unit. As to the Units at the host side which can be connected to NB series Unit by RS-232C or RS-422A through a Host Link, refer to [Appendix-5 List of Models]. 31

33 Communication setting The communication settings need to be set as following values before carrying out communications in the Use Host link. Items Settings Data bit 7bit Stop bit 2bit Parity check Even Communication speed Any value, but the values for the NB Unit and the host must be the same. Connected Unit No. 00 At the NB Unit side, these settings are made through the PT menu of the NB-Designer. For details, refer to the NB-Designer User Manual [ Serial Port Settings]. For communication settings at the host side, refer to the related PLC manuals as needed Connecting more than one PLC Select the RS-232C method for COM1, and one from RS-232C, RS-422A and RS-485 for COM2. When both of them are used, 2 hosts either from one manufacturer or from two different manufacturers are feasible. (Note: At a certain time, only one from RS-232C, RS-422A and RS-485 can be designated for COM2 to perform communications.) Make sure to keep the connector screws firmly tightened after the communication cable is connected. The maximum tensile load for cables is 30N. Do not apply loads greater than 30N. The communication cables of the COM1 and COM2 connectors are not interchangeable. Confirm the pins of the ports before carrying out communications. 32

34 2-4-3 Settings for each Unit The settings for each Unit are as follows: When connecting to CP-Series Units CP1L-L14/L20/M30/M40/M60 models CP1H-X40/XA40/Y20 models CP1E-N14/N20 models CP1E-N30/N40/N60/NA20 models PLC System Settings Area Write settings directly into the [PLC System Settings Area] with a peripheral tool (CX-Programmer, etc.) based on the model and port of the host. Host model and Port No. Channel No. (*1) Write Value Setting CP1L-M30/M40/M60 models, serial Use Host Link port 1 CP1H-X40/XA40/Y20 models, serial ~000A(*2) Communication speed port Unit No. 00 CP1L-L14/L20 models, serial port 1 CP1L-M30/M40/M60 models, serial port 2 CP1H-X40/XA40/Y20 models, serial port Use Host Link ~000A(*2) Communication speed Unit No. 00 Host model and Port No. Channel No. Write Value Setting CP1E-N14/N20 models, serial port 1 A617.15~12 0 Use Host Link CP1E-N30/N40/N60/NA20 models, serial port 1 A617.11~08 0,3~A(*2) Communication speed A617.07~ data bits, 2 stop bits, Even CP1E-N30/N40/N60/NA20 models, A618.15~12 0 Use Host Link serial port 2 A618.11~08 0,3~A(*2) Communication speed A618.07~ data bits, 2 stop bits, Even *1:The channel No. of CP1L/H is PLC Setup area. *2: The communication speed should be set to the same value as that of the NB Unit. Settings for the front-side DIP Switches Set the front-side DIP switches so as to validate the settings for [PLC System Settings Area]. Set the SW4 to OFF when serial port 1 is used, set SW5 to OFF when serial port 2 is used. As the CP1L-L has only one serial port, it has no DIP switch SW5. 33

35 When connecting to C-Series CPU Units C200HX/HG/HE(-Z) CPM1* CPM2* CQM1H type CPU Units Connection Methods The connection methods for the CPU Units of different PLC models. PLC Models RS-232C connection RS-422A connection C200HX/HG/HE (-Z) CPM1A CPM2A CPM2C CQM1H PLC System Settings Area Write settings directly into the [PLC System Settings Area] (Data memory) with a peripheral tool (CX-Programmer, etc.) based on the model and port of the host. For RS-232C Host Model Channel No. Write Value Setting The RS-232C port built in C200HX/HG/HE(-Z) CPM2A CPM2C CQM1H CPM1A Port A of C200HX/HG/HE(-Z) (*1) Port 1 of CQM1H (*2) Port B of C200HX/HG/HE(-Z) (*1) Connect to the RS-232C port built in the CPU Unit Connect to the RS-232C port (Ports A, B) of the serial communication board Connect to the peripheral port with a dedicated RS-232C adaptor (CPM1-CIF01). Connect to the RS-232C port built in the CPU Unit Connect to the peripheral port with a dedicated RS-232C adaptor Connect to the RS-232C port built in the CPU Unit or the peripheral port with a dedicated conversion cable (CPM2C-CN111 type, CS1W-CN118 type and CS1W-CN114 type) (CPM2C-CN111 type is a cable that divides the Unit port into the RS-232C port built in the CPU Unit and the peripheral port. When connecting to the peripheral port, a RS-232C adaptor (CPM1-CIF01 type) is also needed to be Connect to the RS-232C port built in the CPU Unit Connect to the peripheral port with a conversion cable (CS1W-CN118 type) Connect to the RS-232C port (Port 1) of the serial communication board Connect to the RS-422A port (port A) of the serial communication board Connect to the peripheral port with a dedicated RS-422A adaptor (CPM1-CIF11 type). Connect to the peripheral port with a dedicated RS-422A adaptor (CPM1-CIF11 type). Connect to the peripheral port with a dedicated conversion cable (CPM2C-CN111 type or CS1W-CN114 type) and a RS-422A adaptor (CPM1-CIF11 type) (CPM2C-CN111 type is a cable that divides the Unit port into the RS-232C port built in the CPU Unit and the peripheral port). Connect to the RS-422A port (Port 2) of the serial communication board DM Use Host Link DM (*3) Communication conditions are standard settings. (*4) DM Unit No. 00 DM Use Host Link DM (*3) Communication conditions are standard settings. (*4) DM Unit No. 00 DM Use Host Link DM (*3) Communication conditions are standard settings. (*4) DM Unit No. 00 DM Use Host Link DM (*3) Communication conditions are standard settings. (*4) DM Unit No

36 *1: The RS-232C port of the Communication Board. *2: The RS-232C port of the Serial Communication Board. *3: is the set value of the communication speed. Set the communication speed to the same value as that of the NB Unit. *4: Standard settings of the Communication conditions are as follows: Start bit: 1 bit, Data bit: 7 bit, Stop bit: 2 bit, parity check: even For RS-422A Host Model Channel No. Write Value Setting Port A of C200HX/HG/HE(-Z) (*1) DM Use Host Link DM (*3) Communication conditions are standard settings. (*4) DM Unit No. 00 Port 2 of CQM1H (*2) DM Use Host Link DM (*3) Communication conditions are standard settings. (*4) DM Unit No. 00 *1: The RS-422A port of the Communication Board *2: The RS-422A port of the Serial Communication Board *3: is the set value of the communication speed. Set the communication speed to the same value as that of the NB Unit. *4: Standard settings of the Communication conditions are as follows: Start bit: 1 bit, Data bit: 7 bit, Stop bit: 2 bit, parity check: even For operations on [PLC System Settings Area], refer to the manual of the PLC employed. Connection methods for CPM2C CPM2C only has a connector with the same shape of the CS-Series peripheral port, but the signal cables inside are classified as used for the RS-232C port built in the CPU Unit and for the peripheral port. Therefore, when using CPM2C, differentiate between the settings for the RS-232C port built in the CPU and for the peripheral port based on the conversion cable and port employed to ensure correct use. Besides, when using a simple communication device (CPM2C-CIF21 type), connect to the RS-232C port. For details, refer to the User Manuals (W356) for CPM2C. Use a self-made connection cable to connect the NB Unit and CPM2C. Connect to CPM2C s built-in RS-232C port instead of the peripheral port. When using a simple communication device (CPM2C-CIF21 type), connect to the RS-232C port directly. 35

37 Settings for the front-side DIP Switches To activate the settings of [PLC System Settings Area] (Data memory), set as follows according to the PLC: For C200HX/HG/HE (-Z) and RS-232C of CQM1H For CPM2A For CPM2C (Only the RS-232C port can be connected) 36

38 Setting methods for communication board switches (For RS-422A) For C200HX/HG/HE (-Z) Switch 1: Side (4-wire = RS-422A) Switch 2: ON side (terminal resistance ON = Terminal resistance activated) For CQM1H 2-wire/4-wire switch (WIRE): side (4 wire = RS-422A) Terminal resistance ON/OFF switch (TERM): ON side (terminal resistance ON = Terminal resistance activated) Settings for the communication adaptor switch For RS-232C adaptor (CPM1-CIF01 type) Set the mode setting switch to [HOST] (Up side). For RS-422A adaptor (CPM1-CIF11 type) Set the terminal resistance switch to ON (Up side) 37

39 When connecting to CS-Series CPU Units For CS1G/H-CPU (-V1) types and CS1G/H-CPU H types Connection Methods Connect to the RS-232C port built in the CPU Unit or the RS-232C port of the communication board. When connecting to the peripheral port, a connection cable dedicated for the peripheral port is needed (CS1W-CN118 type). Only RS-232C can be used for connection. PLC System Settings Area When connecting to CS-Series CPU Unit, refer to the following table and set the communication conditions as follows in [PLC System Settings] based on the communication port in use. Connection Methods Channel No. Write Value Setting Use the RS-232C port built in Use Host Link CS1G/H, CS1G/H-H ~000A(*1) Communication speed Unit No. 00 Use the peripheral port of CS1G/H, Use Host Link CS1G/H-H ~000A(*1) Communication speed Unit No. 00 *1:The communication speed should be set to the same value as that of the NB Unit. [PLC System Settings] can be directly set with a peripheral tool (programming console), or it can be set by transmitting the [PLC System Settings] set up by a peripheral tool (CX-Programmer) to the CPU Unit. For details about the [PLC System Settings], refer to [SYSMAC CS Series User Manual] (W339). Settings for the front-side Switches Set the DIP switches 4 or 5 as follows according to the NB-Series port connected. 38

40 When connecting to CJ1-Series CPU Units For CJ1G-CPU type, CJ1G/H-CPU H types and CJ1M-CPU type Connection Methods Connect to the RS-232C port built in the CPU Unit or the RS-232C port of the communication board. When connecting to the peripheral port, a connection cable dedicated for the peripheral port is needed (CS1W-CN118 type). Only RS-232C can be used for connection. PLC System Settings Area (for RS-232C) When connecting to the CJ-Series CPU Unit, refer to the following table and set the communication conditions as follows in [PLC System Settings] based on the communication port in use. Connection Methods Channel No. Write Value Setting Use the RS-232C port built in Use Host Link CJ1G-CPU type, CJ1G/H-CPU H types, ~000A(*1) Communication speed CJ1M-CPU types Unit No. 00 Use the peripheral port of Use Host Link CJ1G-CPU type, CJ1G/H-CPU H types, ~000A(*1) Communication speed CJ1M-CPU type Unit No. 00 *1: The communication speed should be set to the same value as that of the NB Unit. [PLC System Settings] can be directly set with a peripheral tool (Programming console), or it can be set by transmitting the [PLC System Settings] set up by a peripheral tool (CX-Programmer) to the CPU Unit. For details about the [PLC System Settings], refer to [SYSMAC CJ Series User Manual] (W393). Settings for the front-side Switches Set the DIP switches 4 or 5 as follows according to the NB-Series port connected. 39

41 When connecting to CJ2-Series CPU Units For CJ2M-CPU3 type, CJ2M-CPU1 type and CJ2H-CPU6 (-EIP) type Connection Methods Connect to the RS-232C port built in the CPU Unit or the RS-232C port of the communication board. PLC System Settings Area (for RS-232C) Carry out setting by transmitting the [PLC System Settings] set up by a peripheral tool (CX-Programmer) to the CPU Unit. On the [Serial Port] options page of [PLC System Settings], set the connection mode to Host Link: 7 Data Bits, 2 Stop Bits, Even. And set the communication speed to the same as that of the NB Unit. For details about the [PLC System Settings], refer to [SYSMAC CJ2 Series Software User Manual] (W473). Settings for the front-side Switches Set the DIP switch 5 of the CPU Unit as follows according to the NB-Series port connected. 40

42 When connecting to Host Link Units of C-Series Base-mounted type for C200HE(-Z) / C200HG(-Z) / C200HX(-Z) models C200H-LK201/LK202-V1 model Settings for the Switches For C200H-LK201-V1 (RS-232C) [front-side switches] Each switch is a rotary switch. Use a straight screwdriver set the switches as follows to display the numbers and symbols shown in the table. [Back-side switches] 41

43 For C200H-LK202-V1(RS-422A) [front-side switches] Each switch is a rotary switch. Use a straight screwdriver set the switches as follows to display the numbers and symbols shown in the table. [Back-side switches] 42

44 When connecting to a CS-Series Serial Communication Board For CS1W-SCB21 type (Both of port 1 and 2 are RS-232C ports) For CS1W-SCB41 type (Port 1 is RS-232C port and Port 2 is RS-422A/485 port.) (Serial Communication Board for CS-Series CPU Units with RS-232C port, RS-422A port.) Settings for the DM Fixed Allocation Area of the CPU Unit Write settings directly to the [DM Fixed Allocation Area] of the CPU Unit (System Settings Area) with a peripheral tool (programming console or CX-Programmer). After finishing the write-in, the settings can be activated through any of the methods of reconnecting the power supply, restarting the Unit, reactivating the communication port, executing the STUP instruction. The followings are the Channel Nos. and settings of the DM Fixed Allocation Area. It is the same when using RS-232C, RS-422A (port 2 of the CS1W-SCB41 type). DM Fixed Allocation Area (CH) Port 1 Port 2 Write Value Setting DM32000 DM Use Host Link DM32001 DM ~000A (*1) Communication speed DM32003 DM Unit No. 00 *1: The communication speed should be set to the same value as that of the NB Unit. Settings for front-side switches (For RS-422A) 43

45 When connecting to a CS-Series Serial Communication Board For CS1W-SCU21 type (Both of port 1 and 2 are RS-232C ports) Settings for the DM Fixed Allocation Area of the CPU Unit Write settings directly to the [DM Fixed Allocation Area] of the CPU Unit (System Settings Area) with a peripheral tool (programming console or CX-Programmer). After finishing the write-in, the settings can be activated through any of the methods of reconnecting the power supply, restarting the Unit, reactivating the communication port, executing the STUP instruction. The followings are the Channel Nos. and settings of the DM Fixed Allocation Area. m = DM Unit No. (CH) DM Fixed Allocation Area (CH) Write Value Setting Port 1 Port 2 m m Use Host Link m+1 m ~000A (*1) Communication speed m+3 m Unit No. 00 *1:The communication speed should be set to the same value as that of the NB Unit. Settings for the front-side Switches Set the Unit No. of the serial communication Unit by the rotary switch on the front side of the Unit. Use a straight screwdriver set the switches as follows to display the numbers and symbols shown in the table. 44

46 When connecting to a CJ1-Series Serial Communication Unit For CJ1W-SCU41 type (Port 1 is RS-422A/485 port and Port 2 is RS-232C port.) Settings for the DM Fixed Allocation Area of the CPU Unit Write settings directly to the [DM Fixed Allocation Area] of the CPU Unit (System Settings Area) with a peripheral tool (programming console or CX-Programmer). After finishing the write-in, the settings can be activated through any of the methods of reconnecting the power supply, restarting the Unit, reactivating the communication port, executing the STUP instruction. The followings are the Channel Nos. and settings of the DM Fixed Allocation Area. It is the same when using RS-232C, RS-422A. m = DM Unit No. (CH) DM Fixed Allocation Area (CH) Write Value Setting Port 1 Port 2 m m Use Host Link m+1 m ~000A (*1) Communication speed m+3 m Unit No. 00 *1:The communication speed should be set to the same value as that of the NB Unit. Settings for the front-side Switches 45

47 Section 3 System Setting Mode This section describes the System Setting Mode 3-1 The display method of System Setting Mode Functions of System Setting Mode

48 3-1 The display method of System Setting Mode Enter the System Setting Mode following the procedures below. 1 Set both the DIP switches SW1 and SW2 on the back side to ON. 2 Press the Reset switch, restart the NB Unit, and then it enters into the System Setting Mode. 3-2 Functions of System Setting Mode The following items can be set in System Setting Mode: 1 Time calibration: check whether the year, month, day, hour, minute and second are the current time values, and if not, rectify them manually. 2 Startup Window No.: the window displayed after launching the NB Unit. The default is window 0. 3 Backlight Saver Time:time to activate the screen saver, and the Unit is minute. The default is 10 minutes. The screen saver is not brought into effect when the set value is 0. 4 Mute Enabled/Disabled: ON/OFF of the buzzer. 5 Brightness Up/Down: with this, brightness of the screen can be adjusted, bringing the screen to its best visual effect. The System Setting Mode screen of the NB7W-TW00B is as follows: 47

49 If you want to change the month, click where the month is (eg. 09), and a digit input keyboard will pop up. Input the month value, and click the Enter button to confirm the change. The System Setting Mode screen of NB5Q-TW00B is as follows: 48

50 Section 4 Calibrate Mode This section describes the Calibrate Mode. 4-1 The display method of Calibrate Mode Functions of Calibrate Mode On-line Touch-control Calibration Function

51 4-1 The display method of Calibrate Mode There are 2 methods for entering into Calibrate Mode. 1 Set the DIP switches SW1 and SW2 on the back side respectively to OFF and ON. Press the Reset switch, restart the NB Unit, and then it enters into the Calibrate Mode. 2 Place a Function Key component in the window, and set its function to Touch Calibration. Click this icon to start Calibrate Mode. 4-2 Functions of Calibrate Mode Procedures to carry out Calibrate Mode: Track and touch the + displayed on the screen and you will hear a click. Carry on with this, until the + disappear followed by a "TP Adjust Success! turning up on the screen. Set both of the DIP switches SW1 and SW2 to OFF, press the Reset switch again. 4-3 On-line Touch-control Calibration Function Besides using the DIP switches, Touch-control Calibration can also be achieved with a function key while the software is running, thus sparing the time of equipment adjustment and the trouble of opening the control panel. For details, refer to the NB-Designer User Manual [3-7-2 Function Keys]. 50

52 Section 5 Maintenance and Troubleshooting This section describes the maintenance and inspection methods for preventing errors occurring, and troubleshooting measures when errors occur. 5-1 Maintenance Troubleshooting Request to change the NB Unit

53 5-1 Maintenance Maintain the PT to keep it in its optimal condition. Do not attempt to take the product apart and do not touch the product inside while the power is being supplied. Otherwise it may result in electric shock. Backing Up Project Data When the PT needs to be repaired or the Unit needs to be replaced for any fault, always backup the project data and save it properly. Standby Unit Have a standby Unit at hand so that when the currently employed PT fails, or the screen becomes blurry because of running out of its backlight lifetime, the system can be restored quickly. 52

54 5-2 Troubleshooting When a problem occurs during operation, refer to the listed problems below for the corresponding solutions Software Trouble 1. The condition of the USB driver for the HMI If NB5Q/NB7W can not perform normal downloading/uploading, it s usually because the USB driver is not set up properly. Setup Method: During the process of the software setup, the PC will automatically prompt you to set up the USB driver. You can choose the correct setup method according to the displayed information, click the [Still Proceed] at the final step to complete the process. However, if the automatic setup fails, you can still perform the setup manually. Connect the Unit and the PC with a USB cable, energize the Unit, and a prompt to set up new hardware will pop up at the right bottom corner. Following the displayed information, choose [Install from a list specific location (Advanced)], and find the USB driver in the driver file of NB-Designer s installation directory. 2. The NB-Designer software can run in XP/Vista/Win7 systems. It is compatible with XP, Vista and Win7 operating systems. Pay attention to the following items when using Windows Vista/7: A You must log in Vista/Win7 operating systems as the administrator. B When running the NB-Designer, right-click the mouse on the icon "NB-Designer.exe" to select "Compatible with XP". C When running the NB-Designer for the first time, right-click the mouse on the icon "NB-Designer.exe" to select "Run as Administrator". And then, run the software directly. 53

55 3. How to change system parameters like user level passwords and Baud rate. These are all controlled by the local special register. These system parameters can be found by double-clicking the component attributes, and selecting [System register]. For example, the addresses for changing the password online are: LW10022~10023 Password/0 level Occupying a double word; LW10024~10025 Passowrd/1 level Occupying a double word; LW10026~ Password/level 2 Occupying a double word; besides,lw10118~10143 Password/level 3~15 Occupying double word * 13. If the level 2 password needs to be changed, set in the software as follows: First, Place a Number Input component on window, check [System Register], then select LW10026, as shown below 54

56 Select [Password] for the Data Type in the attributes page of [Numeric Data], as follows: The process is the same for changing other system parameters online. But note that after changing the following system parameters, the HMI needs to be rebooted to validate the changes. System Parameter Setting: the following addresses will take effect after reboot. Addresses Descriptions comments Initial Window number 0~ Screen saver (backlight saver) 0 (OFF, Constant, Screen saver inactivated) 1~600 minutes (activated) Common window/pop-up window 0: Normal 1: Higher than other windows Common window/attribute 0: Lower than the Base window 1: Higher than the Base window Storage event number 0~ RTC source 0: PLC(Local Word) 1: Internal RTC Default language 0~ System reserve HMI internal use 55

57 4. The difference between User permissions and User levels User levels: there is a difference between high-level users and low-level users high-level users can access low-level windows, while low-level users can not access high-level windows. Whole windows can be encrypted based on user levels. User permissions: user permissions are not restricted by user levels. As long as the user s name and password are input correctly, the component which is set limited for access to it can be operated. With the user permission, user accounts can be added or deleted. User permissions only work on components, and has nothing to do with the window password. 5. What if the uploading password or the online change password of the HMI is lost? If the uploading password of HMI is lost, data can t be uploaded, and the only solution is to download the project again to overwrite the original one. Similarly, if the online change password is lost, it also requires to download the project again and set a new password. Thus, in order to guarantee the safety of users' projects, please back up the original projects, for decryption is not within our service range. 6. Why can t the system time be changed during offline simulation? Offline simulation uses the PC s clock, therefore the time can t be changed. It can only be changed when downloaded to the HMI. 7. How to use the Operator Confirm function? When the user is fabricating a screen, some buttons may require a second confirmation to validate the operation, and at this time, the Operator Confirm function can fit well here. This function can control components. For example, you can check the [Operator Confirm] on the [Control Setting] attributes page of the bit status setting component, as shown below: A dialog box as follows will pop up once this option is checked: 56

58 8. When opening a project, what if there is a prompt: [Font not existing in the system]? For example: if attempting to open a project involving in a PC that doesn t incorporate, a prompt [ doesn t exist] will pop up, as follows: If this font issue is ignored, will be replaced with a font that exists in the system, eg. UnBatang. 9. How to set the addresses of the component for displaying warnings and events, and how to inquire warnings and events? It s best to use the internal register of the HMI LW for the address type of the component for displaying warnings and events, and the address can be designated as any of the vacant address in the project. When we record warnings and events on HMI, one page is almost certainly not enough, then turn-page inquiring is needed to be set, thus the address in the attributes of the component for displaying warnings and events takes effect. Take LW10 for an example, as follows: Use two [Multi-State Setting Component] as the Page Up/Down button, designate the button address the same as the component for display, and set as follows in the attributes page of [Multi-State Setting]. 57

59 Note: Incremental upper limit is determined by how many events the customer wants to record, while the decremental lower limit is recommended to be set to Why is there one event inquiring record less? When the customer set the [Multi-State Setting component] for Page Up/Down, the lower limit is set to 1, which will cause the records to be one less. The correct setting is as follows: 11. How to keep the time in the event record and in the PLC synchronized? Check [Use The External Clock for Event] in [HMI Attribute] [HMI Extended Attributes], as follows: Meanwhile, clock register data inside the PLC is also needed to be transmitted to the local register LW For details, refer to the NB-Designer User Manual [ HMI Extended Attributes]. 58

60 12. Why can t the history events be saved even if saving is selected? In most of this kind of cases, although the customer selects to save them, the No. of events to be saved which is 0 by default is not changed to the No. the customer needs, thus the problem occurs. In this case, just set the No. of events to be saved to make it work. This is done in [HMI Attribute] --- [Historical Events Storage], as follows: 13. The cause of HMI prompting RTC Device error and the solution When HMI prompt RTC Device error, it s probably because the clock chip fails. If the recipe component or the system time is not used, this notice can be shielded without affecting other operations. The method to shield it is: place a [Bit State Setting Component] in the project s common window, with the address set to LW.B and the set type to [Set On when Window Open] status. 14. What if there is one digit less when displaying negative numbers, or it displays ****? When the data type in the software is decimal, the minus sign also occupies a bit, therefore one more integer bit is needed. 15. When switching the screens with a PLC, why can t the screen being set up be accessed repeatedly? It s likely because the value of the PLC address through which screen switching is set doesn t change. When switching the screen and leaving it in other ways (eg. by screen switching button), as the value of the PLC address doesn t change, the screen can t be accessed repeatedly with PLC control. Solution: add a [Multi-State Setting component] to the window of leaving designated screen, with the address set to the same as the one in [PLC Control Change Window], and the attribute to [Set at Window Close] (This value can be set as a negative). 16. When calling a screen with a direct window, why doesn t the target screen show up completely? When calling a target screen with a direct window, the left top corner is taken as the base point. If the size of the direct window component is smaller than then target window, the display may be incomplete. Therefore, when editing the target screen, place the component with the left top corner as the base point and make sure that the size of the target screen is the same as that of the direct window component. 17. Components on the screen such as the indicator, button etc. won t show up properly, while offline simulation still works as normal. It may be caused by communication disruption between the HMI and the slave. If the communication fails and the component on the screen takes the slave s address, components like the indicator and buttons will not show up properly. Restoring the communication will solve this problem. With respect to how to restore the disrupted communication, refer to communication-related issues in this manual. 59

61 18. Can the HMI be restarted without interrupting the power supply? There are two ways to restart it without interrupting the power supply: Method 1: Press the RESET button on the back of the panel to restart it. Method 2: Make a [Bit State Switch] component, with the address as LB9045. When LB9045=1, the HMI will restart. 19. How to make the HMI s buzzer sound when a warning occurs? Set Buzzer Warning in the warning settings, and the buzzing time can be set as required, as shown below: 20. When the backlight is dimmed, how to light it up by means of the PLC addresses? Select the PLC control component, then select [Backlight Open], as shown below: 60

62 21. Why does the characters input as text turn up as messy codes? This may be because the text input Component or the Note Book Component involves vector fonts. When inputting Chinese characters, the text input Component and the Note Book Component do not support vector font, but only support Dot Matrix Font, as shown below: 22. How to skip to the target screen after inputting the password correctly? Place a Function Key Component on the screen, and overlay it with a Trigger Touch component. Assume that the device address of the Trigger Touch Component is LB10 and the Trigger Type of it is OFF->ON, then select Trigger Register in the control settings of the attributes of the Number Input Component for password input. Cause the LB10 to be turned ON after setting the attribute to After Written Notice. When the password is input correctly, it can directly skip to the screen switched by the Function Key. Note: The function of the Trigger Touch Component is equivalent to clicking the area covered by the Trigger Touch. When the trigger condition is satisfied, the components in this area will be executed. 61

63 23. What if a warning: no newline at end of file pop up when compiling a macro program When compiling a program, a macro instruction compiling warning warning: no newline at end of file pops up on the Message window. No error is found after check, but the warning persists after compiling. In this situation, input an enter at the last row of the macro instruction, as follows: 24. Why does a System Cash: SegV appear after calling a macro program? The likely causes are as follows: A The address range specified in the macro instruction exceeds the actual address B When using array data, the array data range exceeds limits. For example: when defining int array [10], if array [10] is used, there will be an issue of array exceeding limits. C When proceeding division operation, the denominator is 0, and no judgment is made. D An endless loop forms in the macro. 25. Why can t a project edited recently be renamed after closing the NB-Designer? The project file names can t be changed directly, and the only way to rename a project is to use the [Save As] option in the [File] menu. 26. How to achieve indirect addressing with an index register? The function of the index register: realizing the indirect addressing mode of the register. The component s new input/output address = its original input/output address + the word address of the index register. After checking [Use the index register], click the arrow and a window as follow will turn up. 62

64 27. How to make sure that pictures imported are not distorted? Cut the picture with a drawing tool first. For example, if a 320*240 picture is to be fitted on a screen with a resolution of 800*480, use Image Software to set the width at 320 and the height at 240 in Edit >Resize, then import it into the configuration project, as shown below. 28. When a new project is created, what roles do the windows coming with the system play respectively, and can they be deleted? It s better not to delete or alter the windows coming with the system, especially for new users, because each window plays a specific role. The indications of the windows are as follows: Window 0: default Startup Window (Frame 0), which can be used for editing the first page. Window 1: Common Window, in which there are two direct windows used for ejecting the numeric keyboard coming with the system, and what is more, all the components in the Common Window work in any of windows of the project. Window 2: Fast Selection Window, used for ejecting the taskbar, and users can place a page-turning button in this window. Windows coming with the system also include: NUM keyboard ASCII keyboard HEX Keyboard Operator Confirm Window: this window is used together with the [Operator Confirm] of the attributes page of [Control Setting]. You can change the attributes of the windows coming with the system in [HMI Extended Attributes] of [HMI Attribute], as shown below: 63

65 29. What methods are there for triggering (executing) macro programs There are 5 kinds of triggering methods for macro instructions, from which users can choose the triggering methods they need. Method 1: [HMI Attribute] > [HMI Extended Attributes] > [Use INIT Macro]: When the HMI is energized and started, the set macro program is executed once, as shown below: 64

66 Method 2: [Function Key] > [Execute Macro]: each time the Function Key is clicked, the macro program is executed once, as shown below: Method 3: [Timer] > [Execute Macro]: The triggering and execution of the macro program is controlled by time. 65

67 Method 4: [PLC Control] > [Execute Macro Program]: The execution of the macro program is controlled by the PLC address. 66

68 Method 5: [Event Information] > [Execute Macro]: the macro program is triggered and executed by events, and when the set event condition is satisfied, the macro program is executed. 30. What formats of pictures does NB-Designer support, and how to import these pictures? The formats of pictures that can be imported include:.jpg,.gif,.bmp and.png. Import method: A Create a new figure, and select Bitmap 67

69 B In the dialogue box that pops up, right-click Load Image. C Choose the picture to be imported D After a successful import, the imported picture can be used in programs 31. How to restrict programs in the HMI from being uploaded? In [HMI Attribute] > [HMI Extended Attributes] > [Allow Upload], set a password to achieve this purpose, as shown below: 68

70 After a password is set, the password needs to be entered correctly to carry out uploading, or not, the uploading can t proceed; you can disable uploading completely by deselecting [Allow Upload]. If [Allow Decompilation] is selected and a password is set, the correct password is required to be entered to proceed with decompilation. If [Allow Decompilation] is deselected, decompilation can t be performed even after a project is uploaded. Note that if the project is large and decompilation is not required, then decompliation can be deselected to save the storage space of the HMI. 32. How to mask system alarm information - PLC No Response Place a [Bit State Setting Component] in the Common Window, with the address being LW.B and the setting type being [Set On when Window Open]. 33. How to mask system alarm information - Socket Connect Error Place a [Bit State Setting Component] in the Common Window, with the address being LW.B and the setting type being [Set On when Window Open]. 34. How to achieve multi-language switch Multi-language switch can be achieved through changing the value of the special register LW9130. The default setting is: LW9130=0, with the corresponding language 1. NB-Designer supports up to a maximum of 32 languages. The following is an example of Chinese - English switching: LW9130=0: Language 1 >Chinese LW9130=1: Language 2 >English 1. Create a text in the text library, as shown below: 69

71 2. Add a [Bit State Switch] and a static text on the screen, with the Use TextLib selected for tags, as shown below: 70

72 71 3. Add two Multi-State Setting Components on the screen, with both of the addresses being LW9130, the setting Mode being Set Constant, the values set to 0 and 1 (0: Chinese display, 1: English display); online language switching can be achieved by changing the value of LW When activating the English" button, the screen will be displayed in English, and when activating the Chinese button, the screen will be displayed in Chinese, as shown below:

73 5-2-2 Communication-related Troubles 1. What if the communication between the PLC and HMI fails Many customers experienced communication problems between the HMI and PLC when they used HMI. As this happens, follow the procedures below to check what is going wrong. A Check whether the hardware connections are correct or not, especially whether the fabrication of the communication cable correct or not; B Check the COM port parameters in the HMI attributes settings are set correctly or not, such as the Baud Rate, Word Length, Efficacy, and PLC Station No., etc. and make sure the HMI serial port communication parameter settings are in consistent with that of the slave Unit; C Is the communication serial port selected correctly? For example, if COM1 is selected in software configuration, but COM2 is used actually, this would be considered wrong; D Use the serial programming cable of the PLC to download PLC programs, and make sure the downloading go smoothly. Exit the downloading mode and use the [Direct Online Simulation] function of the NB-Designer by clicking [Tool] > [Direct Online Simulation]. If the [Direct Online Simulation] communication fails, it is likely because the communication parameters of the HMI and PLC are inconsistent. In this case, check the communication parameter settings of the PLC and HMI; E If the [Direct Online Simulation] functions well, please check the efficacy of the communication cable of the HMI and PLC (If it s the user who make the cable, please check whether the male and female pins are deployed in right correspondence, and whether there is false soldering.); F If all turn right following the above procedures, but communications still won t work, please contact the supplier. 2. Components can t be displayed simultaneously after a page-turn, and in some cases, they turn up after a few seconds This is probably due to a low communication speed. With respect to the solution, refer to [3. Why is the communication between the HMI and slave Unit slow and how to improve it]. 3. Why is the communication between the HMI and slave Unit slow and how to improve it The possible causes of a slow communication: A There are too many components on a single screen communicating with the slave Unit, and besides, the addresses are not continuous: B The macro program calls too many addresses of the salve Unit directly, and it s not recommended to directly use slave Unit addresses in a macro program; C The Common Window or some other window employs too many timers; D Too many background components such as Trend Curve, XY Plot and historical data are employed, and the background components are running all the time; E Warning and Event Information Registration addresses are too many and not continuous; F Too many PLC control components are used; G On-site Interference; H Too many vector font formats are used, while the font formats featured in a project should be as few as possible; I Too many bitmaps are used; J Too many windows pop up, such as direct windows and indirect windows; K There are too many controllers communicating with the HMI and too many communication addresses. Solutions: A Components on a single screen communicating with the slave Unit should be as few as possible; B Try to keep the addresses of the components on a single screen communicating with the slave Unit continuous; C Try to use HMI s internal addresses for variables in a macro program. If there is a need for exchanging data between the touch panel and slave Unit communication components, resort to the data transmission function of the timer or data transmission components; D Keep a minimum of number of channels of background components such as Trend Curve, XY plot and historical data display components, etc. and make sampling periods as long as possible; E Try to keep Warning and Event Information Registration addresses continuous; F Do not use too many PLC control components; 72

74 G Use a shielded cable for the communication cable. Keep it at least 10 CM away from power lines, and make sure the system is grounded properly; H Try to use tag fonts when programming. Try to use less vector fonts, and when using vector fonts, keep font formats as few as possible. 4. PLC No Response:what is the meaning of XX-XX-X XX-XX-X means: HMI number PLC station number HMI serial port number. For example, means the No.0 HMI using the serial port COM1 loses communication connection to the controller with the station number 1. The serial port number is defined as: 01/02 represent COM1/COM2. 5. The causes for a project downloading failure Downloading through USB fails: Check whether hardware connections are still functioning well or not, then check through the following factors A USB driver is not installed successfully. B USB driver has been damaged. Find the driver at NB-Designer/driver and reinstall it; C The USB downloading cable has been damaged, so replace it; D The USB port of the HMI or the PC fails; E Electromagnetic interference is affecting the USB downloading cable. Make sure the system is grounded properly. Downloading in the serial mode fails: A [Tool] menu > [Downloading Mode Options] > Whether [Serial] is selected. B Whether the serial No. of the PC is correct; C The serial port is occupied or problems arise to the PC serial port; D The fabrication of the communication cable is incorrect or the bonding wire falls off; E The downloading cable is plugged incorrectly, and it should be plugged to the COM1 port with the label indicating the NB Unit; F The serial port of the HMI fails (The serial port does not support hot plug, so take care and avoid man-made damage). 6. How to decide whether communications are normal or not through the internal addresses of the HMI Decide which station breaks off through a bit; Serial port 2: LW , 16 words are equivalent to 256 bits, with each bit corresponding to a PLC. No response = ON, Normal = OFF. See the following diagram: Assume that 3 S7-200 PLCs connect to the COM2 port of NB7W, the station numbers of which are 2, 3, 4 respectively; if the PLCs with the station numbers 2 and 4 fail communication, the internal registers LW.B and LW.B will turn ON automatically, as shown below: 73

75 7. The communications of the PT and PLC are normal, but why are some numeric values are indicated as **** When the data coming from registers communicating with the PLC exceeds the setting range of the Number Display or Number Input, **** will appear. It indicates an overflow of a numeric value. The user can set the integer bit digit number range of the Number Display or Number Input larger through the software to make numeric value display normal. For example, change the integer bit digit number from 3 to Why is the window-switching speed of the PT becoming slow after macro instructions are used When writing macro-code programs, if a large of number of address variables of the PLC or slave Unit are defined, the execution speed of the PT may suffer. When executing a macro program, the processor picks up the variable addresses defined first, executes macro operation, then carries out output. If the macro program is executed at a high frequency, a large amount of time is used to perform communication with the slave Unit, thus affecting the execution speed of the PT as a whole. 74

76 9. When PT communicates with S7-200, why can t the VD address value be displayed A First check whether the VD in the PLC is a double integer type or a single-precision floating-point number, then set the right data type on the PT; B The settings on the PT are consistent with the coding format on the PLC. Check whether the BIN format is adopted, while with BCD format, the display will fail Hardware Troubles 1. How to calibrate the system time of the PT There are 2 methods to calibrate the time: Method 1: there are 2 DIP switches on the backside of the PT. Tweak both of the DIP switches 1 and 2 to ON, reboot the PT, then the Setup Screen turns up, as shown below: (take NB5Q-TW00B as an example) Click the time component, input the current time. Method 2: Create a new project, and place 7 Number Input components on the screen, with each of the addresses LW10000~LW10006 respectively corresponding to the Second, Minute, Hour, Day, Month, Year and Week The time can thus be calibrated through changing the values of these 6 Number Input components. 2. The time can t be saved or the display is not accurate If the time can t be saved, the most likely cause is that the battery runs low. When the PT is disconnected from the power supply, the data hold area on the PT and the RTC both need to be energized by the battery on the PT mainboard. When the battery voltage descends to an unsustainably low level, it may cause that the time can t be saved or the display is not accurate, therefore requiring the Unit to be sent back to the factory for battery replacement. 3. Why does the data in the PT recipe register disappear after a power interruption When the PT is disconnected from the power supply, the data hold area on the PT and the RTC both need to be energized by the battery on the PT mainboard. When the battery voltage descends to an unsustainably low level, it may lead to loss of data, therefore requiring the Unit to be sent back to the factory for battery replacement. 4. Why is there no response from touch-control When operating the touch panel, if clicking a component on the screen doesn t receive a proper response, the first thing you have to do is to make sure that this button is indeed operable. If it is confirmed, the problem may result from a touch-control shift. The touch panel is a panel of 4-wire precision resistors, and because the resistors are subject to impacts from temperature, humidity and also 75

77 their own characteristics, it s recommended that touch-control calibration be carried out yearly. Calibration method: tweak the DIP switch 2 on the backside of the PT to ON and restart the PT. A + will appear on the screen. Click it, the + will shift after the PT responds. You have to click again and after a total of 5 consecutive clicks, the PT will prompt you whether the calibration is a success. If it is a success, the PT will skip to the user program screen, while if it is not a success, the "+ will pop up again, requiring another round of calibration. Note: After a successful calibration, the DIP switch 2 needs to be set back to OFF, or not, the system will prompt you for a calibration every time you turn on the power supply. 5. Why is the PT touch-control not responding or insensitive The likely causes are as follows: A The communications are abnormal, and when this happens, the touch-control may not respond; B The touch-control shifts, and change of the operation environment or the touch panel characteristics may cause the touch-control to be unable to respond; C The touch panel is damaged or the touch-control circuit suffers a poor contact; Solutions: A Resolve the communication problem; B Try out a touch-control calibration; C Send it back to the factory for tests. 6. Why does the PT screen dim or even become black The screens we normally see on a PT are displayed in liquid crystal. However, the liquid crystal itself doesn t give out light, so it is usually used together with a light source, and so far, the most commonly used light-emitting equipments for industrial PT products are of CCFL or LED backlight. The NB-Series touch panel employs LED backlight. LED backlight: LED, (i.e. Lighting Emitting Diode), is a kind of semiconductor solid light-emitting device. It uses solid semiconductor chips as the light-emitting material. Surplus energy breaks out during the process of combination of charge carriers in the semiconductor, triggering photon emissions, and this is used to display various kinds of information, such as characters, graphics, images, animations, quotations, videos and video signals on display panels. The generally used LED backlight is made up of an array, e.g. an array of 3*4 with a total of 12 LEDs, and if one or even more LEDs are not working normally, the screen will dim. When none of the LEDs is working normally, the screen will be totally black. When your PT product dims or becomes totally back, please contact OMRON s customer service center. 7. PT black screen The possible causes for a black screen are as follows: A The power supply to the PT is abnormal; B The PT enters the screen saver (backlight saver) mode; C Control backlight OFF is set through the PLC Control Component; D Backlight broken; E The LCD panel is damaged. Solutions: A Check the power supply to the PT, use a multimeter to measure whether the voltage is within the normal range or whether the output power is too low; B Click the PT screen to exit the screen saver mode; C Check whether control backlight OFF is set through the PLC Control Component in the PT program; D Please contact OMRON s customer service center. 8. PT white screen and flickering screen The causes of a white screen or a flickering screen: the ambient temperature exceeds the range specified on the PT nameplate, or the liquid crystal is damaged. Solutions: Check the ambient temperature and compare it with that specified on the PT, or contact OMRON s customer service center. 9. The serial port gets heated when the PT communicates with other devices Check the grounding of the PT and other communication devices. If the grounding is not shared, there is a possible significant voltage difference between the devices, leading to a heavy current, thus causing a heated serial port. 76

78 5-2-4 Other Troubles 1. During Direct Online Simulation, the internal data of the PLC is readable, but not alterable Check whether the internal storage addresses of the PLC is writable or not. If the address property is Read only, the data can t be changed; then check whether the communication cable is normal or not. 2. What is the difference between the USB Host and Slave ports USB Slave port is used only for downloading/uploading data and executing functions related to the NB-Designer, and not for communicating with the slave Units. USB Host port can be connected to a USB flash disk, or a USB-interfaced mouse, keyboard, barcode scanner, printer, etc. According to the appearance, the Slave port is customarily called [Square port], while like the USB port on a PC, the Host port is customarily called [Flat port]. The USB Slave port is as shown below: 3. What influences do on-site interferences have on the PT, and what are the countermeasures On an industrial site, various kinds of interferences will be encountered inevitably. Interferences may cause the following troubles for the touch panel. A A small information window displaying PLC NO RESPONSE appears intermittently; B Communications with the PT breaks off, whenever an inverter, motor, transformer or some other equipment alike starts; C The PT crashes; D The touch-control of the PT becomes insensitive. The interference issue is a rather complicated one, and the commonly used methods for handling this issue include: A Anti-strong-electricity-interference Keep weak electricity cables such as communication cables, signal cables and control cables away from strong electricity, with a minimum distance of 20 CM, and do not lay them parallel with strong electricity cables. If possible, wire them through iron tubes, and if the cable duct is multilayered, lay the weak electricity cables below the strong electricity ones. B Anti-inner-cabinet-interference It s recommended that the alternating current cables and the direct current cables be laid in separate channels, and if laid in the same channel, the weak electricity cables and the strong electricity ones need to be bundled separately, and be kept as far away as possible. C Signal cable anti-interference Employ STP cables, and ground the shielding layer at one side or add a magnetic ring. D Anti-inverter-interference Connect a filter to the power-supply side of the inverter, and shroud it with a metal casing. E Every equipment needs to be grounded properly. F Use a separate switching power supply for the PT. 77

79 5-3 Request to change the NB Unit Follow the following precautions to change the NB Unit, if a fault is detected during the check-up. Back up the project data in the NB Unit. All project data will be deleted when OMRON repairs the NB Unit. Prior to replacing the NB Unit, switch off the power supply. When obtaining a new PT, check and confirm that the new NB Unit is faultless. When sending the faulted NB Unit back to OMRON for repair, provide a file detailing the fault together with the NB Unit to the OMRON representative. 78

80 Appendices Appendix-1 Specifications Appendix-2 External Dimensions Appendix-3 RS-422A/485 Connections Appendix-4 Fabrication of the Connection Cable Appendix-5 List of Models Appendix-6 List of Options

81 Appendix-1 Specifications Appendix-1-1 General Specifications Items Rated power supply voltage Allowable power supply voltage fluctuation range NB5Q-TW00B model Specifications NB7W-TW00B model DC24V DC20.4~27.6V(DC24V -15%~+15%) Power consumption 6W 7W Ambient operating temperature 0 C~50 C Ambient storage temperature -20 C~60 C Ambient operating humidity 10%~90% RH (without condensation) Ambient storage humidity 10%~90% RH (without condensation) Operating environment No corrosive gases Noise Immunity Compliant with IEC , 2KV (Power cable) Vibration resistance (During operation) 10 to 57Hz with a mm amplitude, 57 to 150Hz 9.8m/s 2 for 30 min each in X, Y and Z directions Shock resistance (During operation) 147m/s 2 for 3 times each in X, Y and Z directions, with each time lasting for 11 ms Dimensions 184 (W) 142 (H) 46 (D)mm 202 (W) 148 (H) 46 (D)mm Panel opening dimension (Width) (Height) mm (Width) (Height) mm Panel thickness range: 1.6~4.8 mm Panel thickness range: 1.6~4.8 mm Weight 620g max. 710g max. Front operation part: IP65 Degree of protection (Dust proof and drip proof only from the front of the panel) Battery life 5 years (at 25 C) Applicable standards EC Directives, KC Appendix-1-2 Performance Specifications Display specifications Specifications Items NB5Q-TW00B model NB7W-TW00B model Display device 5.6"TFT LCD 7"TFT LCD Display Pixels 320 horizontal 234 vertical 800 horizontal 480 vertical panel Display color colors Valid display area 113 (Width) 85 (Height) mm 154 (Width) 86 (Height) mm Backlight Life 50,000 hours of operating time at the normal temperature (25 C) The backlight will be compromised at low temperatures. And the luminous intensity of each LED may decrease by 50%. Front-side LED ON: power connected OFF: power disconnected 80

82 Operation part specifications Items NB5Q-TW00B model Specifications NB7W-TW00B model Touch panel Type: resistance type Resolution: 4096*4096 Operation force: 0.8~1.2 N Press endurance: min. 1,000,000 times Note: the operation part is of an analog resistive film type. When two or more points on the panel are pressed simultaneously, the switch at the center of the pressed area may act if there is one. Therefore, do not press two or more points on the panel simultaneously. External I/F Specifications Items NB5Q-TW00B model Specifications NB7W-TW00B model USB Slave 1 port (for screen data transmission and connection to a PC) Programmer (a software for making screen data) Items NB5Q-TW00B model Specifications NB7W-TW00B model Name NB-Designer NB-Designer is free distributed on Omron web site. Please access your local Omron web site and try to download. Appendix-1-3 Communication Specifications Host Link communication specifications Items NB5Q-TW00B model Specifications NB7W-TW00B model COM1 COM2 Compliant with EIA RS-232C D-sub, 9-pin connector socket Pin 6 DC +5V output (Max. 250 ma) Communication cable length: Max.15m Compliant with EIA RS-232C/422A/485 D-sub, 9-pin connector socket At one point, only one from RS-232C, RS-422A and RS-485 can be designated to perform communications Communication cable length: Max.15m (RS-232C) Max. 500m (RS-422A/485) 81

83 Appendix-2 External Dimensions NB5Q-TW00B model 82

84 NB7W-TW00B model 83

85 Appendix-3 RS-422A/485 Connections Appendix-3-1 Grounding and Shielding of the Cables When performing communications using RS-422A/485, carry out the connections, shielding and grounding as follows: Grounding wiring The NB Unit has a functional grounding terminal ( ). 1 Generally, make the grounding according to Fig. (a) Connect the grounding terminals (GR) of the devices and the functional grounding terminal ( ), then make a D-type grounding at point 1 (Max. grounding resistance 100 Ω) Short-circuit the LG terminal and GR terminal of the PLC. Use a cable with a minimum of 2 mm 2 for the grounding cable. For details about the connection methods, refer to the related communication Unit manuals. 2 When grounding the Unit with noise source equipments such as motors and inverters, etc. from the same panel, do not ground the NB Unit s functional grounding terminal ( ) as shown in Fig. (b) Shielding of RS-422A/485 Cables Be sure to shield the RS-422A/485 cables. Connect the grounding terminals (GR) of the devices and the functional grounding terminals ( ), and when making a D-type grounding at point 1 (Max. grounding resistance 100 Ω), carry out a single-end shielding according to Fig. (a). If grounding is not done to the functional grounding terminal ( ) of the NB Unit, shield both ends as shown in Fig. (b) In order to avoid malfunctions caused by interferences, shield the cables properly. 84

86 85

87 Appendix-4 Fabrication of the Connection Cable Fabricate the connection cable following the procedures below. Appendix-4-1 Cable Processing 1 Cut the cable to the required length. 2 Use a tool like a razor, etc. to cut off the ethylene peel of the cable. Be care not to damage the shielding layer (for grouping purpose) 3 Use a pair of scissors to snip off the shielding layer. 4 Bring out the core of each wire using a wire stripper. 5 Fold back the shielding layer. 6 Wrap the folded part of the shielding layer with aluminum foil tape. 86

88 Appendix-4-2 Soldering Sheathe each wire with a heat shrinkable tube. Place some standby soldering tin on each wire and each pin of the connector. Solder each wire and each pin of the connector. 4 Pull the heat shrinkable tubes back to the soldering parts, heat them with a heat shrinking gun to make them shrink. Appendix-4-3 Shield Assembly Assemble the connector shield as shown below. 87

89 Appendix-4-4 Method for fabricating the cable for connection to OMRON PLC When fabricating the cable for connecting the NB Unit and OMRON PLC, refer to the following methods: COM1 The cable for connecting the NB Unit serial port COM1 to OMRON PLC (RS-232C) COM2 The cable for connecting the NB Unit serial port COM2 to OMRON PLC (RS-232C) The cable for connecting the NB Unit serial port COM2 to OMRON PLC (RS-422A) 88

90 Appendix-4-5 Method for fabricating the cable for connection to PC When fabricating the cable for connecting with NB-Designer, refer to the following methods: Depending on the type of the RS-232C connector compatible with PCs according to DOS/V, deploy the wiring as shown below: 25-pin Connector 9-pin Connector 89

Name Specifications Model Standards. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

Name Specifications Model Standards. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE SYSMAC Option CSM DS_E_1_1 The RS-232C port of the SYSMAC series can be changed into RS-422A/485 port. The connects directly to a CS/CJ-series RS-232C port and converts RS-232C to RS-422A/485. Features

More information

1% VHULHV 1% 4 7: 1% 4 7: 1% : 7: 1% : 7: % 3URJUDPPDEOH 7HUPLQDOV SETUP MANUAL

1% VHULHV 1% 4 7: 1% 4 7: 1% : 7: 1% : 7: % 3URJUDPPDEOH 7HUPLQDOV SETUP MANUAL SETUP MANUAL NOTE All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording,

More information

CJ1W-INT01. CJ-series Interrupt Input Units. High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 32 Interrupt Inputs.

CJ1W-INT01. CJ-series Interrupt Input Units. High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 32 Interrupt Inputs. CJ-series Interrupt Input Units CSM DS_E 1 High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 3 Interrupt Inputs. Receive inputs to start I/O interrupt tasks. When the

More information

Name Specifications Model Standards RS-422A Converter. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

Name Specifications Model Standards RS-422A Converter. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE SYSMAC Option CSM DS_E_2_1 The RS-232C port of the SYSMAC series can be changed into RS-422A/485 port. The connects directly to a CS/CJ-series RS-232C port and converts RS-232C to RS-422A/485. Features

More information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4. Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting

More information

STARTUP GUIDE MANUAL

STARTUP GUIDE MANUAL Cat. No. V109-E1-11 NB-series NB3Q-TW B NB5Q-TW B NB7W-TW B NB10W-TW01B Programmable Terminals STARTUP GUIDE MANUAL NOTE All rights reserved. No part of this publication may be reproduced, stored in a

More information

NJ-Series Power Supply Unit NJ-PA/PD

NJ-Series Power Supply Unit NJ-PA/PD NJ-Series Power Supply Unit CSM_NJ-PA_PD_DS_E_1_2 Powerful power supply unit to supply stable power to the NJ-series controller. Stable power supply is available from the NJ-series CPU Unit to each I/O

More information

Communication Unit Dedicated for RFID V680 Allowing Direct Connection to OMRON PLC CJ/ CS/NJ-series

Communication Unit Dedicated for RFID V680 Allowing Direct Connection to OMRON PLC CJ/ CS/NJ-series CJ/CS Series ID Sensor Unit CJ1W-V680C11/-V680C12 CS1W-V680C11/-V680C12 CSM_C_1W-V680C1_DS_E_1_1 Communication Unit Dedicated for RFID V680 Allowing Direct Connection to OMRON PLC CJ/ CS/NJ-series Communication

More information

Conductive Level Controller

Conductive Level Controller Conductive Level Controller 61F-D21T-V1 Ideal for level control for industrial facilities and equipment. Outputs can be set to self-hold at ON or OFF using self-holding circuits. Sensitivity adjustment

More information

D5B. Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics. Mechanical Touch Switch. Model Number Structure

D5B. Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics. Mechanical Touch Switch. Model Number Structure Mechanical Touch Switch D5B CSM_D5B_DS_E_3_2 Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics Slow-action switching mechanism used. Gold-plated contact with coil spring

More information

Cat.No. V083-E1-03. NS-Series Programmable Terminals SETUP MANUAL

Cat.No. V083-E1-03. NS-Series    Programmable Terminals SETUP MANUAL Cat.No. V083-E1-03 NS-Series NS12-TS00@-V1, NS12-TS01@-V1 NS10-TV00@-V1, NS10-TV01@-V1 NS8-TV@0@-V1, NS8-TV@1@-V1 NS5-SQ00@-V1, NS5-SQ01@-V1 Programmable Terminals SETUP MANUAL Notice OMRON products are

More information

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4 40 XW2B-40G5 *1 50 XW2B-50G5 60 XW2B-60G5 40 XW2B-40G5-T

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4 40 XW2B-40G5 *1 50 XW2B-50G5 60 XW2B-60G5 40 XW2B-40G5-T Standard-type Connector- Conversion Units XWB CSM_XWB_DS_E Simplifies Connector and terminal block replacement, and requires less in-panel wiring. Mount to DIN Track or via screws. MIL Flat Cable Connectors

More information

NPN output. 200 mm. Type Cable length Model Remarks

NPN output. 200 mm. Type Cable length Model Remarks Retroreflective Photomicrosensor with Lens CSM DS_E_5_2 Photomicrosensor with light modulation for reduced external light interference. Easy adjustment and optical axis monitoring with a light indicator.

More information

Model NPN output PNP output Standard. configuration

Model NPN output PNP output Standard. configuration Slot-type Photomicrosensor (Non-modulated) *1 EE-SX4/6 CSM_EE-SX4_6_DS_E 1 Global Standard Slot-type photomicrosensors with 0- to 100-mA direct switching capacity. Series includes models that enable switching

More information

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm Digital Amplifier Ultrasonic Sensor CSM DS_E_1_1 A Reflective Sensor That Handles All Types of Sensing Object Colors and Patterns Compact with a Broad Selection of Side-view Heads Slim with analog outputs

More information

E2K-X4ME1 2M E2K-X4ME2 2M

E2K-X4ME1 2M E2K-X4ME2 2M Cylindrical Proximity Sensor EK- CSM_EK-_DS_E 1 General-purpose Threaded Sensor That Detects Metals and Non-metals Alike Detects both metallic and nonmetallic objects (water, oil, glass, plastic, etc.).

More information

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring.

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring. CQM1 I/O CSM_CJ1W-AT4 DS_E_1_1 Easy and secure replacement by reusing the I/O terminal block wiring You can replace CQM1(H) Series with CJ Series, efficiently using your assets. Time for wiring works and

More information

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter Solid-state Timer Solid-state Timer with Variable Time Ranges Four time ranges are selectable per timer unit. Wide timing range of 0.05 second to 30 hours can be covered by a combination of five timer

More information

Cat.No. V034-E1-5 NT30/30C. Programmable Terminal OPERATION MANUAL

Cat.No. V034-E1-5 NT30/30C. Programmable Terminal OPERATION MANUAL Cat.No. V034-E1-5 NT30/30C Programmable Terminal OPERATION MANUAL NT30/30C Programmable Terminal Operation Manual Revised January 2001 Notice: OMRON products are manufactured for use according to proper

More information

Output configuration Contact form Operation indicator Cable length Model PNP open collector. 1 m D5F-2B10 (+ common) ON when operated

Output configuration Contact form Operation indicator Cable length Model PNP open collector. 1 m D5F-2B10 (+ common) ON when operated High-precision Optical Switch D5F CSM_D5F_DS_E_2_2 Optical System Achieves 1-μm Operating Position Repeatability in this 4-way Switch No-contact structure for high reliability. Ceramic materials in measuring

More information

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2. Terminal SSR G3S CSM_G3S_DS_E_7_ Compact Terminal SSR with Outputs Easy-to-use SSR block that combines four compact G3S SSRs, sockets, and heat sink in one unit. Easy wiring with separate I/O terminal

More information

Limit Switch Connectors

Limit Switch Connectors CSM_LimitSwitch DS_E s (SC Series) Cabtire cables and flexible tubes with various diameters are used to connect machine tools and controllers with Limit Switches. To ensure the watertightness of the edges

More information

Model Number Structure

Model Number Structure Total Counter/Time Counter (DIN 8 x ) CSM DS_E DIN 8 x -mm Total Counter/Time Counter with Easy-to-read Displays and Water and Oil Resistance Equivalent to IP66 High-visibility, negative transmissive LCD

More information

Model Number Structure

Model Number Structure Solid State Relays G3@-VD CSM_G3F_G3FD_DS_E_4_2 International Standards for G3F Series, Same Profile as MY Power Relays Shape-compatible with mechanical relays. Certified by UL, CSA, and VDE (model numbers

More information

Limit Switch Connectors

Limit Switch Connectors CSM_LimitSwitch_Connector_DS_E Connectors (SC Series) Cabtire cables and flexible tubes with various diameters are used to connect machine tools and controllers with Limit Switches. To ensure the watertightness

More information

Snap-in (front mounting) Locking type. Terminals Solder terminals *1 Color Light gray Black A7BL-207 *2 A7BL *2

Snap-in (front mounting) Locking type. Terminals Solder terminals *1 Color Light gray Black A7BL-207 *2 A7BL *2 Thumbwheel Switch ABS/ABL CSM_ABS_ABL_DS_E Wide Range of Locking-type s Available Character height of. or. mm makes for easy-toview display. Installation is easy with snap-in mounting. The series includes

More information

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel I/O Relay CSM DS_E_2_ Slim-styled I/O Relay Saves Space in Panel SPST-NO, SPST-NC, and SPDT contact forms available for output (SPST-NO only for input). Ultra-slim housing measuring 29 (W) x 0 (D) x 2

More information

EE-SX97 40% Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. Slot-type Photomicrosensor.

EE-SX97 40% Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. Slot-type Photomicrosensor. Slot-type Photomicrosensor EE-SX CSM_EE-SX_DS_E Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. A built-in connector minimizes the shape and dimensional

More information

Handheld Reader Writer

Handheld Reader Writer Handheld Reader Writer CH1D-V2 A Compact Lightweight Easy-to-use Pen-type Reader Writer. Connects directly to a personal computer or PLC via RS-232C. The Reader Writer s protective construction is IP63

More information

Cat. No. V072-E1-02. NS-Series Programmable Terminals SETUP MANUAL

Cat. No. V072-E1-02. NS-Series    Programmable Terminals SETUP MANUAL Cat. No. V072-E1-02 NS-Series NS12-TS00@, NS12-TS01@ NS10-TV00@, NS10-TV01@ NS7-SV00@, NS7-SV01@ Programmable Terminals SETUP MANUAL No. 6182 OMRON Corporation Read and Understand this Manual Please read

More information

Cat. No. V220-E1-02. CS1PC-PCI01-DRM CS1PC-PCI01H-DRM CS1PC-EIC01 SYSMAC CS1 Board

Cat. No. V220-E1-02. CS1PC-PCI01-DRM CS1PC-PCI01H-DRM CS1PC-EIC01 SYSMAC CS1 Board Cat. No. V220-E1-02 CS1PC-PCI01-DRM CS1PC-PCI01H-DRM CS1PC-EIC01 SYSMAC CS1 Board CS1PC-PCI01-DRM CS1PC-PCI01H-DRM CS1PC-EIC01 SYSMAC CS1 Board Operation Manual Revised July 2005 iv Notice: OMRON products

More information

Model Number Structure

Model Number Structure Digital Panel Meter CSM DS_E_2_1 Easy-to-use, w-cost Digital Panel Meter that Accepts AC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. ghly visible display

More information

CX-One Ver.4. FA Integrated Tool Package CX-One. Greater Integration with the CX-One. Features

CX-One Ver.4. FA Integrated Tool Package CX-One. Greater Integration with the CX-One. Features FA Integrated Tool Package CX-One CX-One Ver.4 CSM_CX-One_DS_E_2_1 Greater Integration with the CX-One The CX-One is a comprehensive software package that integrates PLC Programming Software with Support

More information

Model Number Structure

Model Number Structure Solid State Relays CSM DS_E_2_1 I/O SSRs That Mount to OMRON s G7TC I/O Block Input and output modules are available in wide variety. Snaps easily into P7TF I/O Terminals and can be used together with

More information

Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor E2J-W10MA 1M E2J-W20MA 1M. E2J-JC4A Amplifier Unit

Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor E2J-W10MA 1M E2J-W20MA 1M. E2J-JC4A Amplifier Unit Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor Flat Capacitive Sensor with Separate Amplifier Ideal for Mounting on Robot Hands. Flat head is only 5.5-mm thick. Robotics cable ensures

More information

ID Sensor Modules CJ1W-V600C11/V600C12 CS1W-V600C11/V600C12

ID Sensor Modules CJ1W-V600C11/V600C12 CS1W-V600C11/V600C12 ID Sensor Modules CJ1W-V600C11/V600C12 CS1W-V600C11/V600C12 Integrate Supply Chain Management with Work-in-Process Data Collection by RFID on the PLC Rack These Modules can be combined with OMRON s comprehensive

More information

M16. Cylindrical 16-dia. Indicator. Indicator (Cylindrical 16-dia.) List of Models. Same basic design as the A16 Pushbutton Switch.

M16. Cylindrical 16-dia. Indicator. Indicator (Cylindrical 16-dia.) List of Models. Same basic design as the A16 Pushbutton Switch. Indicator (Cylindrical 16-dia.) CSM DS_E_6_1 Cylindrical 16-dia. Indicator Same basic design as the A16 Pushbutton Switch. Refer to Safety Precautions for All Pushbutton Switches and Safety Precautions

More information

NT11S Programmable Terminal

NT11S Programmable Terminal NT11S Programmable Terminal Operation Manual Produced June 1997 iii OMRON Product References All OMRON products are capitalized in this manual. The word Unit is also capitalized when it refers to an OMRON

More information

Ordering Information. Interface Converter K3SC. List of Models

Ordering Information. Interface Converter K3SC. List of Models Interface Converter CSM DS_E 1 A compact converter that allows communications between /USB and RS-/ devices. Ideal for industrial applications. Allows communications between /USB (Universal Serial Bus)

More information

NT-series Programmable Terminal

NT-series Programmable Terminal NT-series Programmable Terminal Operation Manual Produced June 1997 iii iv OMRON Product References All OMRON products are capitalized in this manual. The word Unit is also capitalized when it refers to

More information

S82S (3/7.5-W Models)

S82S (3/7.5-W Models) Switch Mode Power Supply (3/7.5-W Models) CSM DS_E_4_3 Miniature DIN Rail Mounting DC-DC Power Supplies 65 mm depth enables mounting onto control panels with 100 mm depth. Inputs: 10.2 to 27.6 VDC (DC

More information

Power supply voltage Output configuration Output phases Resolution (pulses/rotation) Model. 100, 200, 360 E6A2-CWZ5C (resolution) 0.

Power supply voltage Output configuration Output phases Resolution (pulses/rotation) Model. 100, 200, 360 E6A2-CWZ5C (resolution) 0. Incremental 25-mm-dia. Rotary Encoder CSM DS_E_5_1 Compact Encoder with External Diameter of 25 mm Incremental model External diameter of 25 mm. Resolution of up to ppr. Be sure to read Safety Precautions

More information

Model Number Structure

Model Number Structure Temperature Controller CSM DS_E_5_1 DIN-sized (48 x 48 mm) Temperature Controller with Analog Setting Compact, low-cost Temperature Controller. Incorporates proportional control and reset adjustment function.

More information

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22. Measuring and Monitoring Relays CSM_K8AB_series_Outline_DS_E_3_2 Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.5 mm Eight slim models featuring a variety of innovative new functions.

More information

CX-One Ver.4. FA Integrated Tool Package CX-One. Greater Integration with the CX-One. Features

CX-One Ver.4. FA Integrated Tool Package CX-One. Greater Integration with the CX-One. Features FA Integrated Tool Package CX-One CX-One Ver.4 CSM_CX-One_DS_E_4_1 Greater Integration with the CX-One The CX-One is a comprehensive software package that integrates PLC Programming Software with Support

More information

EE-SX77/87. Slim, Compact Photomicrosensor that is still easy to use. Photomicrosensor with Slim Cable (Non-modulated) Ordering Information

EE-SX77/87. Slim, Compact Photomicrosensor that is still easy to use. Photomicrosensor with Slim Cable (Non-modulated) Ordering Information Photomicrosensor with Slim Cable (Non-modulated) EE-SX77/87 CSM_EE-SX77_87_DS_E_7_2 Slim, Compact Photomicrosensor that is still easy to use. Compact, thin profile enables dense mounting. Indicator is

More information

GENERAL PRECAUTIONS GENERAL DESCRIPTION... 6

GENERAL PRECAUTIONS GENERAL DESCRIPTION... 6 Cat.No I173E-EN-01 RX Inverter Expansion I/O Board 3G3AX-EIO21-ROE USER S MANUAL GENERAL PRECAUTIONS... 3 1 GENERAL DESCRIPTION... 6 2 INSTALLATION PROCEDURE... 7 2.1 INSTALLING THE EXPANSION I/O BOARD...

More information

Cat. No. Z910-E1-02. DeviceNet Safety WS02-CFSC1-E. NE1A Logic Simulator OPERATION MANUAL

Cat. No. Z910-E1-02. DeviceNet Safety WS02-CFSC1-E. NE1A Logic Simulator OPERATION MANUAL Cat. No. Z910-E1-02 DeviceNet Safety WS02-CFSC1-E NE1A Logic Simulator OPERATION MANUAL DeviceNet Safety WS02-CFSC1-E NE1A Logic Simulator Operation Manual Revised June 2007 iv Notice: OMRON products are

More information

NT30/30C Programmable Terminal

NT30/30C Programmable Terminal Cat. No. V034-E1-5 NT30/30C Programmable Terminal NT30/30C Programmable Terminal Operation Manual Revised January 2001 iv Notice: OMRON products are manufactured for use according to proper procedures

More information

Reliable Detection Unaffected by PCB Holes or Notches. PCB Sensors. Ordering Information. Sensors [Refer to Dimensions on page 4.

Reliable Detection Unaffected by PCB Holes or Notches. PCB Sensors. Ordering Information. Sensors [Refer to Dimensions on page 4. PCB Sensors ES-LS@ CSM_ES-LS DS_E_5_2 Reliable Detection Unaffected by PCB Holes or Notches High-limit ES-LS@ is suitable for incorporation in devices. Wide-range ES-LS@W is ideal for detecting tall components

More information

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure Safety Relay Unit G9 CSM_G9_DS_E The G9 Series Offers a Complete Line-up of Compact Units. Four kinds of -mm wide Units are available: A -pole model, a -pole model, and models with poles and OFF-delay

More information

Programmable Terminal NA-series. Device Connection. User s Manual NA NA NA NA V119-E1-05

Programmable Terminal NA-series. Device Connection. User s Manual NA NA NA NA V119-E1-05 Programmable Terminal NA-series Device Connection User s Manual NA5-15 101 NA5-12 101 NA5-9 001 NA5-7 001 V119-E1-05 NOTE All rights reserved. No part of this publication may be reproduced, stored in a

More information

Programmable Terminal NA-series. Software. User s Manual NA5-15W101 NA5-12W101 NA5-9W001 NA5-7W001 V118-E1-01

Programmable Terminal NA-series. Software. User s Manual NA5-15W101 NA5-12W101 NA5-9W001 NA5-7W001 V118-E1-01 Programmable Terminal NA-series Software User s Manual NA5-15W101 NA5-12W101 NA5-9W001 NA5-7W001 V118-E1-01 OMRON, 2014 All rights reserved. No part of this publication may be reproduced, stored in a retrieval

More information

E2EC. High-sensitivity DC 2-Wire Sensors and Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

E2EC. High-sensitivity DC 2-Wire Sensors and Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information Cable Amplifier Proximity Sensor EEC CSM_EEC_DS_E High-sensitivity DC -Wire Sensors and Subminiature Sensors with Long-distance Detection Shielded Sensor Heads from -mm to M diameters that can be embedded

More information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information Chemical-resistant Proximity Sensor E2KQ-X CSM_E2KQ-X_DS_E_4_3 Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster Excellent resistance against chemicals and oil with fluororesincoated case.

More information

Aluminum-detecting Proximity Sensor (Separate Amplifier Type)

Aluminum-detecting Proximity Sensor (Separate Amplifier Type) Aluminum-detecting Proximity Sensor (Separate Amplifier Type) ECY Simple Teaching Function for Simple Adjustment. Easy-to-see Excess Gain Level Indicators. Detects aluminum, copper, and other non-ferrous

More information

Tina 1A Blanking plug

Tina 1A Blanking plug Original instructions Tina 1A Blanking plug ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

CS1W-B7A. CS-series B7A Interface Unit. It transmits 16 points of I/O signals per word with a pair of cables. Easy and minimized wiring effort,

CS1W-B7A. CS-series B7A Interface Unit. It transmits 16 points of I/O signals per word with a pair of cables. Easy and minimized wiring effort, CPU42 RUN ERR/ALM INH PRPHL/COMN OPEN MCPWR BUSY OPEN PERIPHERAL PORT (RS-232C) CS-series B7A Interface Unit CSM DS_E_3_2 It transmits 16 points of I/O signals per word with a pair of cables. Easy and

More information

Programmable Terminal NA-series. Startup Guide NA NA NA NA V120-E1-03

Programmable Terminal NA-series. Startup Guide NA NA NA NA V120-E1-03 Programmable Terminal NA-series Startup Guide NA5-15 101 NA5-12 101 NA5-9 001 NA5-7 001 V120-E1-03 NOTE All rights reserved. No part of this publication may be reproduced, stored in a retrieval system,

More information

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws Compact Pre-wired Photomicrosensor with Built-in Amplifier (Non-modulated) CSM DS_E_7_1 Meeting Customer Needs with Compact Sensors that Mount with M Screws Both light-on and dark-on outputs provided.

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal.

More information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4. Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting

More information

Programmable Terminal NA-series. Software. User s Manual NA NA NA NA V118-E1-09

Programmable Terminal NA-series. Software. User s Manual NA NA NA NA V118-E1-09 Programmable Terminal NA-series Software User s Manual NA5-15 101 NA5-12 101 NA5-9 001 NA5-7 001 V118-E1-09 NOTE All rights reserved. No part of this publication may be reproduced, stored in a retrieval

More information

C200H-LK401/C500-LK009-V1 PC Link

C200H-LK401/C500-LK009-V1 PC Link Cat. No. W135-E1-3 SYSMAC C200H-LK401/C500-LK009-V1 PC Link PC Link System Manual Revised March 2000 Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator

More information

Model Number Structure

Model Number Structure Temperature Controllers Easy Setting Using DIP Switch and Simple Functions in DIN mm-size Temperature Controllers Easy setting using DIP switch. Models with two alarms added to Series, ideal for temperature

More information

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC Reverse Protection Relay CS DS_E Uses Voltage Detection to Determine Reverse Revolution of Three-phase otor Detects motor reversal due to incorrect wiring. Direction of motor revolution is detected as

More information

No. of I/O points Safety inputs Test outputs Safety outputs NE1A-SCPU01-EIP NE1A-SCPU02-EIP 1.0

No. of I/O points Safety inputs Test outputs Safety outputs NE1A-SCPU01-EIP NE1A-SCPU02-EIP 1.0 Safety Network Controller CSM_NE1A-SCPU0_-EIP_DS_E_1_1 Directly Connected to SYSMAC CS/CJ Series via EtherNet/IP Monitors safety systems via EtherNet/IP. Equipped with master functions of DeviceNet Safety.

More information

Photoelectric Sensor

Photoelectric Sensor Photoelectric Sensor Small General-purpose Photoelectric Sensor with Built-in Power Supply Built-in amplifier accepts wide supply voltage range. Slim, space-saving construction measures only 50 x 50 x

More information

Peripheral Devices for Environment-resistive Slaves

Peripheral Devices for Environment-resistive Slaves Peripheral Devices for Environment-resistive Slaves Peripheral Devices for DeviceNet Communications Ordering Information Environment-resistive Connection Products (for Thin Cable, M Micro Connectors) Product

More information

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws Compact Pre-wired Photomicrosensor with Built-in Amplifier (Non-modulated) EE-SX9 CSM_EE-SX9_DS_E Meeting Customer Needs with Compact Sensors that Mount with M Screws Both light-on and dark-on outputs

More information

USB-Serial Conversion Cable User's Manual

USB-Serial Conversion Cable User's Manual Cat. No. W417-E1-03 USB-Serial Conversion Cable User's Manual USB-Serial Conversion Cable User's Manual Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator

More information

E3S-GS/VS. Both Red-light Models and Greenlight Models to Detect a Wide Variety of Colors. Small Spot/Mark Sensor with Built-in Amplifier

E3S-GS/VS. Both Red-light Models and Greenlight Models to Detect a Wide Variety of Colors. Small Spot/Mark Sensor with Built-in Amplifier Small Spot/Mark Sensor with Built-in Amplifier CSM_E3S-GS_VS_DS_E_2_1 Both Red-light Models and Greenlight Models to Detect a Wide Variety of Colors Be sure to read Safety Precautions on page. Ordering

More information

Switching Frequency Test Conditions (AC3/AC4/AC53-a)

Switching Frequency Test Conditions (AC3/AC4/AC53-a) Information Common to the G3J-T, G3J-S, and G3J CSM_G3J-T_G3J-S_G3J_common_DS_E_2_2 Engineering Data Load Current vs. Ambient Temperature Load current Io (A) G3J-T217BL G3J-T211BL G3J-S211BL G3J-211BL

More information

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M Chip-immune Inductive EEZ CSM_EEZ_DS_E Chip-immune Inductive Correct operation even with aluminum or iron chips sticking to the. Only the sensing object is detected. Pre-wired Smartclick Connector s also

More information

Cat. No. W374-E1-3. SYSMAC CS1 Series CS1W-LC001 Loop Control Unit. Version 2.5 OPERATION MANUAL

Cat. No. W374-E1-3. SYSMAC CS1 Series CS1W-LC001 Loop Control Unit. Version 2.5 OPERATION MANUAL Cat. No. W374-E1-3 SYSMAC CS1 Series CS1W-LC001 Loop Control Unit Version 2.5 OPERATION MANUAL CS1W-LC001 Loop Control Unit Version 2.5 OPERATION MANUAL Revised August 2001 iii Notice of Changes to Information

More information

Smart Sensors (with Ultra-High-Speed CCD Camera) ZFV Series

Smart Sensors (with Ultra-High-Speed CCD Camera) ZFV Series Smart Sensors (with Ultra-High-Speed CCD Camera) ZFV Series Ordering Information Sets of Sensor Head and Amplifier Unit Type NPN Narrow View/Single Function ZFV-R1010 ZFV-R1015 Narrow View/Standard ZFV-R1020

More information

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2 CK3W Power Supply Unit CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2 Supplies power to the CK3M Controller CK3W-PD048 Features 24 VDC input The power supply status indicator shows operating status 1 Ordering

More information

NT20S Programmable Terminal OPERATION MANUAL

NT20S Programmable Terminal OPERATION MANUAL Cat No. V020-E1-04 NT20S Programmable Terminal OPERATION MANUAL i ii NT-series Programmable Terminal Operation Manual Revised August 1997 iii iv OMRON Product References All OMRON products are capitalized

More information

Intelligent Flag Amplifier

Intelligent Flag Amplifier V0 RFID System V0-HAM42-DRT Intelligent Flag Amplifier for CompoBus/D System Configuration Master Unit Master Unit CompoBus/D ( -compatible) I/O I/O V0-HAM42-DRT (Amplifier) V0-HS@@ (Sensors) V0-D@@ (Data

More information

Electroformed Probe Pins XP3A

Electroformed Probe Pins XP3A New Product Electroformed Probe Pins Electroplated Probe Pins for High Reliability The Probe Pin that is made of only one part. The flat structure helps you reduce the pin pitch in comparison with standard

More information

Multi-beam, finger- and hand protection safety sensor. Multi-beam, finger and hand protection safety sensor. Model number structure

Multi-beam, finger- and hand protection safety sensor. Multi-beam, finger and hand protection safety sensor. Model number structure Multi-beam, finger and hand protection safety sensor Multi-beam, finger- and hand protection safety sensor The multi-beam sensors are available in Type 2 (PL c) and Type 4 (PL e) with integrated muting

More information

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor Aluminum-detecting Proximity Sensor EEY CSM_EEY_DS_E_5_1 A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Non-ferrous metals, such as aluminum and brass, are detected.

More information

EtherNet/IP Monitor Tool Operation Manual

EtherNet/IP Monitor Tool Operation Manual EtherNet/IP Monitor Tool Operation Manual Introduction This manual documents the operating procedures of the EtherNet/IP Monitor Tool. It does not contain other information, such as precautions. In actual

More information

E3X-DRT21 (DeviceNet) E3X-SRT21 (CompoBus/S) E3X-CIF11 (RS-422) Fiber Amplifier Sensor Communication Units OPERATION MANUAL

E3X-DRT21 (DeviceNet) E3X-SRT21 (CompoBus/S) E3X-CIF11 (RS-422) Fiber Amplifier Sensor Communication Units OPERATION MANUAL Cat. No. Z152-E1-02 E3X-DRT21 (DeviceNet) E3X-SRT21 (CompoBus/S) E3X-CIF11 (RS-422) Fiber Amplifier Sensor Communication Units OPERATION MANUAL E3X-DRT21 (DeviceNet) E3X-SRT21 (CompoBus/S) E3X-CIF11 (RS-422)

More information

Cat. No. V068-E1-01 NT21. Programmable Terminal. Setup Manual

Cat. No. V068-E1-01 NT21. Programmable Terminal. Setup Manual Cat. No. V068-E1-01 NT21 Programmable Terminal Setup Manual NT21 Programmable Terminal Setup Manual Produced October 2001 iv Notice: OMRON products are manufactured for use according to proper procedures

More information

Cat. No. V231-E1-03. SYSMAC WS02-SPTC1-V1 SPU-Console Ver. 1.3 OPERATION MANUAL

Cat. No. V231-E1-03. SYSMAC WS02-SPTC1-V1 SPU-Console Ver. 1.3 OPERATION MANUAL Cat. No. V231-E1-03 SYSMAC WS02-SPTC1-V1 SPU-Console Ver. 1.3 OPERATION MANUAL WS02-SPTC1-V1 SPU-Console Ver. 1.3 Operation Manual Revised August 2006 iv Notice: OMRON products are manufactured for use

More information

DPDT Basic Switch for Two Independent Circuit Control

DPDT Basic Switch for Two Independent Circuit Control Special-purpose Basic Switch DZ CSM_DZ_DS_E DPDT Basic Switch for Two Independent Circuit Control Ideal for switching the circuits operating on two different voltages, and for controlling two independent

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

Cat. No. W266-E1-09. C200HW-SRM21-V1 CS1W-SRM21 CJ1W-SRM21 CQM1-SRM21-V1 SRT1 Series SRT2 Series. CompoBus/S OPERATION MANUAL

Cat. No. W266-E1-09. C200HW-SRM21-V1 CS1W-SRM21 CJ1W-SRM21 CQM1-SRM21-V1 SRT1 Series SRT2 Series. CompoBus/S OPERATION MANUAL Cat. No. W266-E1-09 C200HW-SRM21-V1 CS1W-SRM21 CJ1W-SRM21 CQM1-SRM21-V1 SRT1 Series SRT2 Series CompoBus/S OPERATION MANUAL C200HW-SRM21-V1 CS1W-SRM21 CJ1W-SRM21 CQM1-SRM21-V1 SRT1 Series SRT2 Series CompoBus/S

More information

Cat. No. W266-E1-09. C200HW-SRM21-V1 CS1W-SRM21 CJ1W-SRM21 CQM1-SRM21-V1 SRT1 Series SRT2 Series. CompoBus/S OPERATION MANUAL

Cat. No. W266-E1-09. C200HW-SRM21-V1 CS1W-SRM21 CJ1W-SRM21 CQM1-SRM21-V1 SRT1 Series SRT2 Series. CompoBus/S OPERATION MANUAL Cat. No. W266-E1-09 C200HW-SRM21-V1 CS1W-SRM21 CJ1W-SRM21 CQM1-SRM21-V1 SRT1 Series SRT2 Series CompoBus/S OPERATION MANUAL C200HW-SRM21-V1 CS1W-SRM21 CJ1W-SRM21 CQM1-SRM21-V1 SRT1 Series SRT2 Series CompoBus/S

More information

Common to all H3CR. Basic Setting. Setting of Selectors. Selection of Operating Mode. Selection of Time Unit and Time Range. Common to all H3CR 1

Common to all H3CR. Basic Setting. Setting of Selectors. Selection of Operating Mode. Selection of Time Unit and Time Range. Common to all H3CR 1 Common to all H3CR Note: The undermentioned is common for all H3CR models. Basic Setting Setting of Selectors The s can be turned clockwise and counterclockwise to select the desired time unit, time range,

More information

Number of input channels

Number of input channels Safety Relay Unit (Sensor Connector Type) CSM DS_E_3_1 Less Wiring Required with Safety Light Curtain Sensor connector allows direct connection to OMRON 3SJ Safety Light Curtains with PNP outputs. Reduces

More information

Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series Smart Slave Analog I/O Terminals.

Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series Smart Slave Analog I/O Terminals. CS-series Net Unit CSM DS_E_5_3 A Net Unit for the CS Series That Boasts Industry-leading Performance and Functions Features Allows control of up to 32,000 points (2,000 words) per master, and ensures

More information

Dedicated I/O Units OPERATION MANUAL

Dedicated I/O Units OPERATION MANUAL Cat. No. W238-E1-10 SYSMAC CQM1H/CQM1 Series Dedicated I/O Units OPERATION MANUAL CQM1H/CQM1Series Dedicated I/O Units Operation Manual Revised November 2003 iv Notice of Changes to Information on Conformance

More information

OPERATION MANUAL. SYSMAC CX-Position Ver Downloaded from Elcodis.com electronic components distributor

OPERATION MANUAL. SYSMAC  CX-Position Ver Downloaded from Elcodis.com electronic components distributor Cat. No. W433-E1-05 SYSMAC CXONE-AL@@C-EV2/ CXONE-AL@@D-EV2 CX-Position Ver. 2.4 OPERATION MANUAL CXONE-AL@@C-EV2/ CXONE-AL@@D-EV2 CX-Position Ver. 2.4 Operation Manual Revised June 2007 iv Notice: OMRON

More information

Machine Automation Controller. NJ-series. Troubleshooting Manual NJ NJ NJ W503-E1-01

Machine Automation Controller. NJ-series. Troubleshooting Manual NJ NJ NJ W503-E1-01 Machine Automation Controller NJ-series Troubleshooting Manual NJ501-1300 NJ501-1400 NJ501-1500 W503-E1-01 OMRON, 2011 All rights reserved. No part of this publication may be reproduced, stored in a retrieval

More information

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information Cable Amplifier Proximity Sensor EEC CSM_EEC_DS_E_8_ Subminiature Sensors with Long-distance Detection Shielded Sensor Heads from -mm to M diameters that can be embedded in metal. Robotics cables provided

More information

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC Solid-state Timer CSM DS_E_4_1 Miniature Timer Compatible with the MY Relay Semi-multi power supply voltage. Large transparent time setting knob facilitates time setting. A flat-blade and Phillips screwdriver

More information

NT-series Programmable Terminal Operation Manual

NT-series Programmable Terminal Operation Manual NT-series Programmable Terminal Operation Manual Cat. No. V022-E3-1 OMRON Product References All OMRON products are capitalized in this manual. The word Unit is also capitalized when it refers to an OMRON

More information

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001 NX-Series Power Supply Unit CSM_NX-PA_PD_DS_E_2_2 Powerful power supply unit to supply stable power to the NX-series controller. Stable power supply is available from the NX-series CPU Unit to each I/O

More information