Villa Sistemi Medicali DRF 4343
|
|
- Claribel Sharp
- 5 years ago
- Views:
Transcription
1 Digitec S.r.l. Via Caduti Lecchesi a Fossoli, LECCO Italy digitec@digiteclecco.com Villa Sistemi Medicali DRF 4343 Network and Media Interchange DICOM Conformance Statement August 13, 2009 Draft Ver. 1.1 Copyright by Digitec S.r.l., Lecco Italy. Digitec S.r.l. reserves the right to change any part of this document without prior notice. All rights on this publication are reserved. No part of this publication may be reproduced without prior explicit written permission from Digitec S.r.l.
2 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V1.1 2 Table of Contents DOCUMENT HISTORY NETWORK: INTRODUCTION IMPLEMENTATION MODEL Application data flow diagram Functional definitions of AE's Sequencing of real-world activities AE SPECIFICATION HNDI specification Association establishment policy General Number of associations Asynchronous nature Implementation identifying information Association initiation by real-world activity Communication verification Associated real-world activity Proposed presentation contexts SOP specific conformance statement for Verification SOP Class Transfer of a still image Computer Radiography Image Storage Associated real-world activity Proposed presentation contexts SOP specific conformance statement for CR Image Storage SOP Class Transfer of a still image Digital X-Ray Image Storage For Presentation Associated real-world activity Proposed presentation contexts SOP specific conformance statement for DX Image Storage SOP Class Transfer of a still image X-Ray Angiographic Image Storage Associated real-world activity Proposed presentation contexts SOP specific conformance statement for XA Image Storage SOP Class Transfer of a still image X-Ray Radiofluoroscopic Image Storage Associated real-world activity Proposed presentation contexts SOP specific conformance statement for XRF Image Storage SOP Class Printing of a still image Associated real-world activity Proposed presentation contexts SOP specific conformance statement for DICOM Print Service Classes Basic Film Session SOP Class Basic Film Box SOP Class Basic Grayscale Image SOP Class Uploading worlist Associated real-world activity Proposed presentation contexts SOP specific conformance statement for Modality Worklist SOP Class... 27
3 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V Creating and updating Modality Performed Procedure Step Associated real-world activity Proposed presentation contexts SOP specific conformance statement for Modality Performed Procedure Step SOP Class Requesting Storage Commitment Associated real-world activity Proposed presentation contexts SOP specific conformance statement for Storage Commitment SOP Class Querying and retrieving studies Associated real-world activity Finding studies Proposed presentation contexts SOP specific conformance statement for Patient Root Q/R IM - FIND SOP Class SOP specific conformance statement for Study Root Q/R IM - FIND SOP Class Retrieving studies Proposed presentation contexts SOP specific conformance statement for Patient Root Q/R IM - MOVE SOP Class SOP specific conformance statement for Study Root Q/R IM - MOVE SOP Class Association acceptance policy Remote communication verification Associated real-world activity Presentation context table SOP specific conformance statement for Verification SOP Class Presentation context acceptance criterion Transfer syntax selection policies Remote image instances receiving Associated real-world activity Presentation context table SOP specific conformance statement for CR/DX/XA/XRF Storage SOP Class Presentation context acceptance criterion Transfer syntax selection policies COMMUNICATION PROFILES Supported communication stacks TCP/IP stack API Physical media support EXTENSIONS/SPECIALIZATIONS/PRIVATIZATIONS CONFIGURATION AE title/presentation address mapping Configurable parameters SUPPORT OF EXTENDED CHARACTER SETS MEDIA INTERCHANGE: INTRODUCTION IMPLEMENTATION MODEL Application data flow diagram Functional definitions of AE's... 42
4 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V Sequencing of Real-World Activities File Meta Information options AE SPECIFICATIONS HMSI specifications File Meta Information for HMSI Real-World Activity for HMSI Real-World Activity: Create CD/DVD Application Profiles for the RWA: Create CD/DVD Options AUGMENTED AND PRIVATE PROFILES Augmented Profiles AUG-GEN-CD SOP Class Augmentation Directory Augmentations Other Augmentations Private Profiles EXTENSIONS, SPECIALIZATIONS, PRIVATIZATIONS OF SOP CLASSES AND TRANSFER SYNTAXES CONFIGURATION CHARACTER SET... 45
5 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V1.1 5 DOCUMENT HISTORY V1.0 First release of this document. It claims conformace to Verification SCP/SCU, Storage CR/DX/XA/RF SCU, Storage Commitment SCU, Basic Grayscale Print SCU, Modality Worklist SCU, MPPS SCU, Dicom Media FSC services. V1.1 Added conformace to Query/Retrieve SCU service.
6 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V1.1 6 NETWORK CONFORMANCE STATEMENT 0 NETWORK: INTRODUCTION Digitec HirisRf43 is a computed radiography modality device capable to acquire up to 2880x2880 pixels images and to manage up to 16Kx16K pixels reconstructed images. Digitec HirisRf43 is equipped with a Hiris Network Data Interface (HNDI) that allows the transfer of images according with DICOM 3.0 standard. This document describes the conformance of HNDI to DICOM 3.0 standard. 1 IMPLEMENTATION MODEL HNDI is an application capable to verify application level communication between two DICOM 3.0 peers as well as to store and print images on remote DICOM interfaced archives an printers. HNDI can manage worklist received from HIS/RIS and acts a a SCU for storage commitment and MPPS Dicom services. HNDI can find and retrieve studies stored remotely. 1.1 Application data flow diagram A dedicated menu commands starts communication DICOM services to peer selected in the remote DICOM applications list. See figure Verify, get worklist, store, request storage commitment, print, send MPPS or Query and Retrieve Studies command HNDI Remote verify, get worklist, store, executes storage commitment, print, executes MPPS, get back studies DICOM standard interface Figure HNDI Implementation Model 1.2 Functional definitions of AE's When HNDI is invoked, it starts an association to the destination AE with an opportune Presentation Context to verify the communication, to get worklist, to store/print an image, to request storage commitment, to notify an MPPS and to find and retrieve remote stored studies. It returns the command exit status to be displayed on the main monitor (depending on status return code). 1.3 Sequencing of real-world activities Not applicable.
7 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V AE SPECIFICATION HNDI is configured as a single application. HNDI provides Standard Conformance to the following DICOM V3.0 SOP Class as a SCU: SOP Class Name SOP Class UID Verification SOP Class Computed Radiography Storage SOP Class Digital X-Ray Image Storage For Presentation SOP Class X-Ray Angiographic Image Storage SOP Class X-Ray Radiofluoroscopic Image Storage SOP Class Storage Commitment Service Class Basic Grayscale Print Management Meta SOP Class Modality Worklist Information Model - FIND SOP Class Modality Performed Procedure Step SOP Class Patient Root Query/Retrieve Information Model FIND SOP Class Patient Root Query/Retrieve Information Model MOVE SOP Class Study Root Query/Retrieve Information Model FIND SOP Class Study Root Query/Retrieve Information Model MOVE SOP Class HNDI provides Standard Conformance to the following DICOM V3.0 SOP Class as a SCP: SOP Class Name SOP Class UID Verification SOP Class Computed Radiography Storage SOP Class Digital X-Ray Image Storage For Presentation SOP Class X-Ray Angiographic Image Storage SOP Class X-Ray Radiofluoroscopic Image Storage SOP Class
8 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V HNDI specification Association establishment policy General HNDI tries to establish an association whenever is invoked by with a valid "destination" field. The list of "destination" known by the system is configurable. The maximum PDU size that will be negotiated is 60KB Number of associations Only one association a time is allowed Asynchronous nature No asynchronous operations window negotiation will be performed Implementation identifying information HNDI supplies the Implementation Class UID The version name provided is "DIGITEC V4.0" Association initiation by real-world activity Communication verification Associated real-world activity The request to verify DICOM communication starts an association negotiation Proposed presentation contexts A single Presentation Context is offered for an association, with Abstract Syntax related to the "Verification SOP Class" and Transfer Syntax "Implicit VR Little Indian". No extended negotiation is performed. Default SCU role is assumed. See table Table Proposed presentation context for HNDI Verification Abstract Syntax Transfer Syntax Role Extended Negotiation Name UID Name UID Verification SOP Class DICOM Implicit VR Little Endian Transfer Syntax SCU None SOP specific conformance statement for Verification SOP Class Standard Conformance is provided to the Verification SOP Class ( ) of the DICOM Image Storage Service Class. No attribute is associated with C-ECHO service.
9 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V1.1 9 HNDI accepts status codes from C-ECHO service and performs actions as in the following list: H Success. The writing "<Aetitle> verification OK" is displayed and the association is closed Transfer of a still image Computer Radiography Image Storage Associated real-world activity If HirisRad is configured to use the CR Storage service, the request to transfer a CR still image starts an association negotiation for the CR Storage Service Proposed presentation contexts A single Presentation Context is offered for an association, with Abstract Syntax related to the "Computed Radiography Image Storage" and Transfer Syntax "Implicit VR Little Indian". No extended negotiation is performed. Default SCU role is assumed. See table Table Proposed presentation contex for HNDI CR-Storage Abstract Syntax Transfer Syntax Role Extended Negotiation Name UID Name UID Computed Radiography Image Storage SOP Class DICOM Implicit VR Little Endian Transfer Syntax SCU None SOP specific conformance statement for CR Image Storage SOP Class Standard Conformance is provided to the Computed Radiography Image Storage SOP Class ( ) of the DICOM Image Storage Service Class. The supported attributes of the associated CR image IOD are listed in the table All type 1 attributes will be sent with a length different from zero; all type 2 attributes listed in the table will be sent, possibly with a length of zero. All type 3 attributes may or may not be transmitted, possibly with a length of 0, depending on the parameters passed to HNDI by the application requesting the service. Table CR Image IOD Group Element Attribute Description Type Note Image Type SOP Class UID SOP Instance UID Study Date Series Date Acquisition Date Content Date 2C Study Time 2
10 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V Series Time Acquisition Time Content Time 2C Accession Number Modality 1 Fixed CR Manufacturer Institution Name Institution Address Referring Physician's Name Station Name Study Description Procedure Code Sequence 3 > Include Code Sequence Macro E Series Description Performing Physicians' Name Manufacturer s Model Name Referenced Performed Procedure Step Sequence >Referenced SOP Class UID 1C >Referenced SOP Instance UID 1C Source Image Sequence >Referenced SOP Class UID 1C >Referenced SOP Instance UID 1C Patient's Name Patient's ID Patient's Birth Date Patient's Sex Other Patient ID Patient s Size Patient s Weight Patient s Address Patient's Telephone Numbers Ethnic Group Patient s Occupation Patient Comments Body Part Examined Angio Flag KVP Device Serial Number Software Version Protocol Name 3
11 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V Distance Source to Detector Distance Source to Patient Exposure Time X-Ray Tube Current Exposure Exposure in uas E Image Area Dose Product Imager Pixel Spacing View Position Exposure Time in us X-Ray Tube Current in ua D Study Instance UID E Series Instance UID Study ID Series Number Instance Number Patient Orientation 2C Laterality 2C Samples per Pixel 1 Fixed: "1" Photometric Interpretation 1 Fixed: "MONOCHROME2" Rows Columns Pixel Spacing Pixel Aspect Ratio 1C Bits Allocated 1 8,16 (Configurable) Bits Stored 1 8,10,12,14,16 (Configurable) High Bit 1 Bits Stored Pixel Representation 1 Fixed: "0" Burned In Annotation Performed Procedure Step ID Performed Procedure Step Description Performed Protocol Code Sequence 3 > Include Code Sequence Macro Request Attribute Sequence > Requested Procedure ID 1C Calibration Image 3 7FE Pixel Data 1 HNDI accepts status codes from C-STORE service and performs actions as in the following list:
12 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V H Success. The writing "Transfer complete" is displayed and the association is closed H to 0212H. Error. The writing "Error xxx" is displayed and the association is closed H Resource limitation. The writing "Failure: resource limitation" is displayed and the association is closed. - A7xxH Out of resources. The writing "SCP out of resources" is displayed and the association is closed. - CxxxH Cannot understand. The writing "Failure: error Cxxx" is displayed and the association is closed. - BxxxH Warning. The writing "Warning: error Bxxx" is displayed and the association is closed Transfer of a still image Digital X-Ray Image Storage For Presentation Associated real-world activity If HirisRad is configured to use the DX Storage service, the request to transfer a DX still image starts an association negotiation for the DX Storage Service Proposed presentation contexts A single Presentation Context is offered for an association, with Abstract Syntax related to the "Digital X- Ray Image Storage For Presentation" and Transfer Syntax "Implicit VR Little Endian". No extended negotiation is performed. Default SCU role is assumed. See table Table Proposed presentation contex for HNDI DX-Storage Abstract Syntax Transfer Syntax Role Extended Negotiation Name UID Name UID Digital X-Ray Image Storage For Presentation SOP Class DICOM Implicit VR Little Endian Transfer Syntax SCU None SOP specific conformance statement for DX Image Storage SOP Class Standard Conformance is provided to the Digital X-Ray Image Storage For Presentation SOP Class ( ) of the DICOM Image Storage Service Class. The supported attributes of the associated DX image IOD are listed in the table All type 1 attributes will be sent with a length different from zero; all type 2 attributes listed in the table will be sent, possibly with a length of zero. All type 3 attributes may or may not be transmitted, possibly with a length of 0, depending on the parameters passed to HNDI by the application requesting the service. Table DX Image IOD Group Element Attribute Description Type Note
13 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V Image Type SOP Class UID SOP Instance UID Study Date Series Date Acquisition Date Content Date 2C Study Time Series Time Acquisition Time Content Time 2C Accession Number Modality 1 Fixed DX Presentation Intent Type 1 Fixed: FOR PRESENTATION Manufacturer Institution Name Institution Address Referring Physician's Name Station Name Study Description Procedure Code Sequence 3 > Include Code Sequence Macro E Series Description Performing Physicians' Name Manufacturer s Model Name Referenced Performed Procedure Step Sequence >Referenced SOP Class UID 1C >Referenced SOP Instance UID 1C Source Image Sequence >Referenced SOP Class UID 1C >Referenced SOP Instance UID 1C Anatomic Region Sequence 2 Always sent empty Patient's Name Patient's ID Patient's Birth Date Patient's Sex Other Patient ID Patient s Size Patient s Weight Patient s Address 3
14 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V Patient's Telephone Numbers Ethnic Group Patient s Occupation Patient Comments Contrast/Bolus Agent Body Part Examined KVP Device Serial Number Software Version Protocol Name Exposure Time X-Ray Tube Current Exposure Exposure in uas E Image Area Dose Product Imager Pixel Spacing Tomo Layer Height 1C Tomo Angle 1C Tomo Time 1C Detector Type Detector Configuration Exposure Time in us X-Ray Tube Current in ua D Study Instance UID E Series Instance UID Study ID Series Number Instance Number Patient Orientation Image Laterality Samples per Pixel 1 Fixed: "1" Photometric Interpretation Rows Columns Pixel Spacing Pixel Aspect Ratio 1C Bits Allocated Bits Stored High Bit Pixel Representation 1 Fixed: "0"
15 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V Burned In Annotation Pixel Intensity Relationship Pixel Intensity Relationship Sign Window Center 1C Window Width 1C Rescale Intercept Rescale Slope Rescale Type Lossy Image Compression VOI LUT Sequence 1C >LUT Descriptor 1C >LUT Data 1C Performed Procedure Step ID Performed Procedure Step Description Performed Protocol Code Sequence 3 > Include Code Sequence Macro Request Attribute Sequence > Requested Procedure ID 1C Acquisition Context Sequence 2 Always sent empty Calibration Image Presentation LUT Shape 1 7FE Pixel Data 1 HNDI accepts status codes from C-STORE service and performs actions as in the following list: H Success. The writing "Transfer complete" is displayed and the association is closed H to 0212H. Error. The writing "Error xxx" is displayed and the association is closed H Resource limitation. The writing "Failure: resource limitation" is displayed and the association is closed. - A7xxH Out of resources. The writing "SCP out of resources" is displayed and the association is closed. - CxxxH Cannot understand. The writing "Failure: error Cxxx" is displayed and the association is closed. - BxxxH Warning. The writing "Warning: error Bxxx" is displayed and the association is closed.
16 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V Transfer of a still image X-Ray Angiographic Image Storage Associated real-world activity The request to transfer a XA still multiframe image starts an association negotiation for the X-Ray Angiographic Storage Service Proposed presentation contexts A single Presentation Context is offered for an association, with Abstract Syntax related to the "X-Ray Amgiographic Image Storage" and Transfer Syntax "JPEG Lossless, Non-Hierarchical, First-Order Prediction, Process 14, Selection Value 1". No extended negotiation is performed. Default SCU role is assumed. See table Table Proposed presentation contex for HNDI XA-Storage Abstract Syntax Transfer Syntax Role Extended Negotiation Name UID Name UID X-Ray Angiographic Image Storage SOP Class Jpeg Lossless non-hirarchical,first -order Prediction P14 Transfer Syntax SCU None SOP specific conformance statement for XA Image Storage SOP Class Standard Conformance is provided to the X-Ray Angiographic Image Storage SOP Class ( ) of the DICOM Image Storage Service Class. The supported attributes of the associated XA image IOD are listed in the table All type 1 attributes will be sent with a length different from zero; all type 2 attributes listed in the table will be sent, possibly with a length of zero. All type 3 attributes may or may not be transmitted, possibly with a length of 0, depending on the parameters passed to HNDI by the application requesting the service. Table XA Image IOD Group Element Attribute Description Type Note Image Type SOP Class UID SOP Instance UID Study Date Series Date Acquisition Date Content Date A Acquisition Datetime Study Time Series Time 3
17 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V Acquisition Time Content Time Accession Number Modality 1 Fixed XA Manufacturer Institution Name Institution Address Referring Physician's Name Station Name Study Description Procedure Code Sequence 3 > Include Code Sequence Macro E Series Description Performing Physicians' Name Operator s Name Manufacturer s Model Name Referenced Performed Procedure Step Sequence >Referenced SOP Class UID 1C >Referenced SOP Instance UID 1C Source Image Sequence >Referenced SOP Class UID 1C >Referenced SOP Instance UID 1C Patient's Name Patient's ID Patient's Birth Date Patient's Sex Other Patient ID Patient s Size Patient s Weight Patient s Address Patient's Telephone Numbers Ethnic Group Patient Occupation Patient Comments Contrast/Bolus Agent Body Part Examined Cine Rate KVP Device Serial Number Software Version 3
18 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V Protocol Name Frame Time Vector Distance Source to Detector Distance Source to Patient Estimated Radiogr. Magnif. Factor Field of View Shape Field of View Dimension(s) Exposure Time X-Ray Tube Current Exposure 2C Exposure in uas Radiation Setting A Radiation Mode E Image Area Dose Product Imager Pixel Spacing Grid Positioner Motion 2C Positioner Primary Angle Positioner Secondary Angle Positioner Primary Angle Increment 2C Positioner Secondary Angle Increment 2C Sensitivity Detector Type Detector Configuration Detector Binning Detecotr Active Shape Detector Dimension(s) A Detector Manufacturer s Name B Detector Manufacturer s Model Name Exposure Time in us X-Ray Tube Current in ua D Study Instance UID E Series Instance UID Study ID Series Number Instance Number Patient Orientation Image Laterality Samples per Pixel 1 Fixed: "1" Photometric Interpretation 1 Fixed: "MONOCHROME2"
19 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V Number of Frames Frame Increment Pointer Rows Columns Pixel Spacing Pixel Aspect Ratio 1C Bits Allocated Bits Stored High Bit Pixel Representation 1 Fixed: "0" Quality Control Image Burned In Annotation Pixel Intensity Relationship Lossy Image Compression Performed Procedure Step Start Date Performed Procedure Step Start Time Performed Procedure Step ID Performed Procedure Step Description Performed Protocol Code Sequence 3 > Include Code Sequence Macro Request Attribute Sequence > Requested Procedure ID 1C Calibration Image 3 7FE Pixel Data 1 HNDI accepts status codes from C-STORE service and performs actions as in the following list: H Success. The writing "Transfer complete" is displayed and the association is closed H to 0212H. Error. The writing "Error xxx" is displayed and the association is closed H Resource limitation. The writing "Failure: resource limitation" is displayed and the association is closed. - A7xxH Out of resources. The writing "SCP out of resources" is displayed and the association is closed. - CxxxH Cannot understand. The writing "Failure: error Cxxx" is displayed and the association is closed. - BxxxH Warning. The writing "Warning: error Bxxx" is displayed and the association is closed.
20 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V Transfer of a still image X-Ray Radiofluoroscopic Image Storage Associated real-world activity The request to transfer a XRF still multiframe image starts an association negotiation for the X-Ray Radiofluoroscopic Storage Service Proposed presentation contexts A single Presentation Context is offered for an association, with Abstract Syntax related to the "X-Ray Radiofluoroscopic Image Storage" and Transfer Syntax "JPEG Lossless, Non-Hierarchical, First-Order Prediction, Process 14, Selection Value 1". No extended negotiation is performed. Default SCU role is assumed. See table Table Proposed presentation contex for HNDI XRF-Storage Abstract Syntax Transfer Syntax Role Extended Negotiation Name UID Name UID X-Ray Radiofluoroscopic Image Storage SOP Class Jpeg Lossless non-hirarchical,first -order Prediction P14 Transfer Syntax SCU None SOP specific conformance statement for XRF Image Storage SOP Class Standard Conformance is provided to the X-Ray Radiofluoroscopic Image Storage SOP Class ( ) of the DICOM Image Storage Service Class. The supported attributes of the associated XRF image IOD are listed in the table All type 1 attributes will be sent with a length different from zero; all type 2 attributes listed in the table will be sent, possibly with a length of zero. All type 3 attributes may or may not be transmitted, possibly with a length of 0, depending on the parameters passed to HNDI by the application requesting the service. Table XRF Image IOD Group Element Attribute Description Type Note Image Type SOP Class UID SOP Instance UID Study Date Series Date Acquisition Date Content Date A Acquisition Datetime Study Time Series Time 3
21 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V Acquisition Time Content Time Accession Number Modality 1 Fixed RF Manufacturer Institution Name Institution Address Referring Physician's Name Station Name Study Description Procedure Code Sequence 3 > Include Code Sequence Macro E Series Description Performing Physicians' Name Operator s Name Manufacturer s Model Name Referenced Performed Procedure Step Sequence >Referenced SOP Class UID 1C >Referenced SOP Instance UID 1C Source Image Sequence >Referenced SOP Class UID 1C >Referenced SOP Instance UID 1C Patient's Name Patient's ID Patient's Birth Date Patient's Sex Other Patient ID Patient s Size Patient s Weight Patient s Address Patient's Telephone Numbers Ethnic Group Patient Occupation Patient Comments Contrast/Bolus Agent Body Part Examined Cine Rate KVP Device Serial Number Software Version 3
22 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V Protocol Name Frame Time Vector Distance Source to Detector Distance Source to Patient Estimated Radiogr. Magnif. Factor Field of View Shape Field of View Dimension(s) Exposure Time X-Ray Tube Current Exposure 2C Exposure in uas Radiation Setting A Radiation Mode E Image Area Dose Product Imager Pixel Spacing Grid Tomo Layer Height 1C Tomo Angle 3C Tomo Time 3C Tomo Type 3C Sensitivity Detector Type Detector Configuration Detector Binning Detecotr Active Shape Detector Dimension(s) A Detector Manufacturer s Name B Detector Manufacturer s Model Name Exposure Time in us X-Ray Tube Current in ua D Study Instance UID E Series Instance UID Study ID Series Number Instance Number Patient Orientation Image Laterality Samples per Pixel 1 Fixed: "1" Photometric Interpretation 1 Fixed: "MONOCHROME2" Number of Frames 1
23 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V Frame Increment Pointer Rows Columns Pixel Spacing Pixel Aspect Ratio 1C Bits Allocated Bits Stored High Bit Pixel Representation 1 Fixed: "0" Quality Control Image Burned In Annotation Pixel Intensity Relationship Lossy Image Compression Performed Procedure Step Start Date Performed Procedure Step Start Time Performed Procedure Step ID Performed Procedure Step Description Performed Protocol Code Sequence 3 > Include Code Sequence Macro Request Attribute Sequence > Requested Procedure ID 1C Calibration Image 3 7FE Pixel Data 1 HNDI accepts status codes from C-STORE service and performs actions as in the following list: H Success. The writing "Transfer complete" is displayed and the association is closed H to 0212H. Error. The writing "Error xxx" is displayed and the association is closed H Resource limitation. The writing "Failure: resource limitation" is displayed and the association is closed. - A7xxH Out of resources. The writing "SCP out of resources" is displayed and the association is closed. - CxxxH Cannot understand. The writing "Failure: error Cxxx" is displayed and the association is closed. - BxxxH Warning. The writing "Warning: error Bxxx" is displayed and the association is closed.
24 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V Printing of a still image Associated real-world activity The request to print a still image starts an association negotiation for the Basic Grayscale Print Management Service Proposed presentation contexts A single Presentation Context is offered for an association, with Abstract Syntax related to the "Basic Grayscale Print Management Meta SOP Class" and Transfer Syntax "Implicit VR Little Indian". No extended negotiation is performed. Default SCU role is assumed. See table Table Proposed presentation contex for HNDI Print Abstract Syntax Transfer Syntax Role Extended Negotiation Name UID Name UID Basic Grayscale Print Management Meta SOP Class DICOM Implicit VR Little Endian Transfer Syntax SCU None SOP specific conformance statement for DICOM Print Service Classes Standard Conformance is provided to the Basic Grayscale Print Management Meta SOP Class ( ) of the DICOM Print Management Service Class. For each SOP Class belonging to the Basic Grayscale Print Management Meta SOP Class a standard conformance is provided; any specific implementation details are described in the following sections Basic Film Session SOP Class N-CREATE. This service will be used to create a Film Session instance. Table shows service attributes. Table Basic Film Session N-CREATE attributes Group Element Attribute Description Note Number of Copies Print Priority Medium Type Film Destination Film Session Label All optional attributes could not be inserted in the message, depending on SCP print features and SCU user selections. N-SET. HNDI never uses this service.
25 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V N-ACTION. This service will be used to create a Print Job Instance to print the whole printing session. No specific attribute will be included. Depending on SCP capabilities, SCU can be configured to print whole session in a single Print Job or to print each film by mean of separated N-ACTION Print Film Box services (see Basic Film Box SOP Class). N-DELETE. This service will be used to delete the whole Print Session after the Print Job instance creation. HNDI accepts status codes from N-CREATE, N-ACTION, N-DELETE services and performs actions as in the following list: H Success. N-CREATE/N-ACTION: the operations continue. N-DELETE: the association is closed and the local copy of the session is destroyed H to 0212H. Error. The writing "Error xxx" is associated to the local copy of the session and the association is closed H Resource limitation. The writing "Error 213H" is associated to the local copy of the session and the association is closed. - CxxxH Failure. The writing "Error Cxxx" is associated to the local copy of the session and the association is closed. - BxxxH Warning. The writing "Error Bxxx" is associated to the local copy of the session and the association is closed Basic Film Box SOP Class N-CREATE. This service will be used to create a Film Box instance. Table shows service attributes. Table Basic Film Box N-CREATE attributes Group Element Attribute Description Note Image Display Format Annotation Display Format ID Film orientation Film Size ID Magnification Type Smoothing Type Border Density Empty Image Density Trim Referenced Film Session Sequence >Referenced SOP Class UID >Referenced SOP Instance UID >Requested Resolution ID
26 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V All optional attributes could not be inserted in the message, depending on SCP print features and SCU user selections. N-SET. HNDI never uses this service. N-ACTION. This service will be used to create a Print Job Instance to print a single Film Box. No specific attribute will be included. Depending on SCP capabilities, SCU can be configured to print each film box separately or to print the whole print session by mean of the N-ACTION Print Film Session service (see Basic Film Session SOP Class). N-DELETE. HNDI never uses this service. HNDI accepts status codes from N-CREATE/N-ACTION services and performs actions as in the following list: H Success. The oerations continue H to 0212H. Error. The writing "Error xxx" is associated to the local copy of the session and the association is closed H Resource limitation. The writing "Error 213" is associated to the local copy of the session and the association is closed. - CxxxH Failure. The writing "Error Cxxx" is associated to the local copy of the session and the association is closed.. - BxxxH Warning. The writing "Error Bxxx" is associated to the local copy of the session and the association is closed Basic Grayscale Image SOP Class N-SET. This service will be used to update a Grayscale Image instance. Table shows service attributes. Table Basic Grayscale Image Box N-SET attributes Group Element Attribute Description Note Image Position Fixed: Preformatted Grayscale Image Sequence >Samples per Pixel Fixed: >Photometric Interpretation Fixed: MONOCHROME >Rows >Columns >Bits Allocated 8,16 (Matches printer capabilities) >Bits Stored 8-16 (Matches printer capabilities) >High Bit (BitsStored-1)-(BitsAllocated-1) (Matches printer capabilities) >Pixel Representation Fixed: 0 7FE >Pixel Data
27 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V All optional attributes could not be inserted in the message, depending on SCP print features and SCU user selections. HNDI accepts status codes from N-SET services and performs actions as in the following list: H Success. The operations continue H to 0212H. Error. The writing "Error xxx" is associated to the local copy of the session and the association is closed H Resource limitation. The writing "Error 213" is associated to the local copy of the session and the association is closed. - CxxxH Failure. The writing "Error Cxxx" is associated to the local copy of the session and the association is closed Uploading worlist Associated real-world activity The request to get the worklist starts an association negotiation for the Basic Worklist Management Service Proposed presentation contexts A single Presentation Context is offered for an association, with Abstract Syntax related to the "Modality Worklist Information Model" and Transfer Syntax "Implicit VR Little Indian". No extended negotiation is performed. Default SCU role is assumed. See table Table Proposed presentation contex for HNDI Worklist Abstract Syntax Transfer Syntax Role Extended Negotiation Name UID Name UID Modality Worklist Information Model - FIND SOP Class DICOM Implicit VR Little Endian Transfer Syntax SCU None SOP specific conformance statement for Modality Worklist SOP Class Standard Conformance is provided to the Modality Worklist Information Model - FIND SOP Class ( ) of the DICOM Basic Worklist Management Service. All the attributes listed in the table will be requested. HNDI, according to the user selections, may request attribute matching as shown in the column Matching Type. HNDI does not consider an error any unsupported attribute matching by SCP (both on optional or on required attributes). Furthermore, it is non considered and error the absence in C-FIND-RSP of any type 1C requested attribute. Table Worklist C-FIND-REQ/RSP Data Set Group Element Attribute Description Type Matching Type
28 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V Accession Number Patient Name 1 Single value / Wildcard Patient ID 1 Single value Patient Birth Date Patient Sex D Study Instance UID Study ID Requested Procedure Description 1C Requested Procedure Code Sequence Scheduled Procedure Step Sequence > Modality 1 Single value or return key > Scheduled Station AE title 1 Single value > Scheduled Procedure Step Start Date 1 Single value / Range matching > Scheduled Procedure Step Start Time 1 Single value / Range matching > Scheduled Performing Physiscian Name > Scheduled Procedure Step Description 1C > Scheduled Protocol Code Sequence > Scheduled Procedure Step ID > Scheduled Station Name > Scheduled Procedure Step Location Requested Procedure ID 3 HNDI accepts status codes from C-FIND service and performs actions as in the following list: H Success. The working list is displayed in a dedicated dialog form. - Any other error code is managed by closing the association and displaying an explicative error writing Creating and updating Modality Performed Procedure Step Associated real-world activity The system can be configured to request the creation and/or setting of remote MPPS on typical events related to examination/images life cycle. These requests start an association negotiation for the Modality Performed Procedure Step Service Proposed presentation contexts A single Presentation Context is offered for an association, with Abstract Syntax related to the "Modality Performed Procedure Step SOP Class" and Transfer Syntax "Implicit VR Little Indian". No extended negotiation is performed. Default SCU role is assumed. See table
29 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V Table Proposed presentation contex for HNDI MPPS Abstract Syntax Transfer Syntax Role Extended Negotiation Name UID Name UID Modality Performed Procedure Step SOP Class DICOM Implicit VR Little Endian Transfer Syntax SCU None SOP specific conformance statement for Modality Performed Procedure Step SOP Class Standard Conformance is provided to the Modality Performed Procedure Step SOP Class ( ). The supported attributes building the data set of N-CREATE and N-SET messages are listed in the tables and All type 1 attributes will be sent with a length different from zero; all type 2 attributes listed in the table will be sent, possibly with a length of zero. All type 3 attributes may or may not be transmitted, possibly with a length of 0, depending on the parameters passed to HNDI by the application requesting the service. Furthermore all attributes labeled with Final State 1 or 2 in the Dicom Standard, will be sent according with that state at least in the data set of one message; the choice of the message including these attributes (N-CREATE or N-SET) will be done according with the availability of the parameters at the moment of the request. Table MPPS N-CREATE Data Set Group Element Attribute Description Type (Final State) Note Modality Procedure Code Sequence Referenced Patient Sequence 2 Always empty Patient Name Patient ID Patient Birth Date Patient Sex E Image Area Dose Product Study ID Performed Station AE title Performed Station Name Performed Location Performed Procedure Step Start Date Performed Procedure Step Start Time Performed Procedure Step End Date 2 (1) Performed Procedure Step End Time 2 (1) Performed Procedure Step Status Performed Procedure Step ID Performed Procedure Step Description 2
30 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V Performed Procedure Type Description Performed Protocol Code Sequence 2 > Include Code Sequence Macro Scheduled Step Attribute Sequence > Accession Number > Referenced Study Sequence 2 Always empty D > Study Instance UID > Requested Procedure Description > Scheduled Procedure Step Description > Scheduled Protocol Code Sequence 2 > Include Code Sequence Macro > Scheduled Procedure Step ID > Requested Procedure ID Total Time of Fluoroscopy Total Number of Exposures E Exposure Dose Sequence > KVp > Exposure Time A > Radiation Mode > X-ray Tube Current in ua Comments on Radiation Dose Performed Series Sequence 2 (1) > Retrieve AE Title 2 (2) E > Series Description 2 (2) > Performing Physician s Name 2 (2) > Operator s Name 2 (2) > Referenced Image Sequence 2 (2) >> Referenced SOP Class UID >> Referenced SOP Instance UID > Protocol Name 1 (1) E > Series Instance UID 1 (1) > Referenced Non-Image Composite SOP Instance Sequence 2 (2) Always empty Table MPPS N-SET Data Set Group Element Attribute Description Type (Final State) Note Procedure Code Sequence E Image Area Dose Product Performed Procedure Step End Date 3 (1)
31 Digitec S.r.l. LECCO HirisRf43 DICOM Conformance Statement V Performed Procedure Step End Time 3 (1) Performed Procedure Step Status Performed Procedure Step Description Performed Procedure Type Description Performed Protocol Code Sequence 3 > Include Code Sequence Macro Total Time of Fluoroscopy Total Number of Exposures E Exposure Dose Sequence > KVp > Exposure Time A > Radiation Mode > X-ray Tube Current in ua Comments on Radiation Dose Performed Series Sequence 3 (1) > Retrieve AE Title 2 (2) E > Series Description 2 (2) > Performing Physician s Name 2 (2) > Operator s Name 2 (2) > Referenced Image Sequence 2 (2) >> Referenced SOP Class UID >> Referenced SOP Instance UID > Protocol Name 1 (1) E > Series Instance UID 1 (1) > Referenced Non-Image Composite SOP Instance Sequence 2 (2) Always empty HNDI accepts status codes from N-CREATE and N-SET service and performs actions as in the following list: H Success. The MPPS notification is internally marked as successful. - Any other error code is managed by closing the association and displaying an explicative error writing Requesting Storage Commitment Associated real-world activity The system can be configured to request the storage commitment of each image transferred to a remote SCP with any of the above descripted storage services. This request starts an association negotiation for the Storage Commitment Service. The association is always started with the remote AE receiving the image by means of the Storage Service.
DICOM 3.0 Conformance Statement for PlatinumOne Systems
DICOM 3.0 Conformance Statement for PlatinumOne Systems 0.0 Revision History: Revision ECN Date Description A 3032 09/12/2002 New Release 1.0 Purpose: Define the DICOM Conformance statement associated
More informationDAR-8000 Series DICOM Conformance Statement
Series DICOM Conformance Statement for 03.01.xx No. : S517-1070 Rev. : D [NO TEXT] 2 0.0 Revision History: Revision Date Description First Edition 2005/08/03 New Release A 2005/11/09 Added Worklist B 2006/03/02
More informationRaffaello Conformance Statement for DICOM V3.0
Raffaello Conformance Statement for DICOM V3.0 Copyright 2003-2006 by I.M.S. s.r.l. DOCUMENT VERSIONS Version Date Author Changes 1.00 04-Oct-03 IMS s.r.l. First Version 1.01 27-Feb-04 IMS s.r.l. Updated
More informationREGIUS CONSOLE CS-2. Revision History. Date Version Description 02/08/2004 Ver This Conformance Statement applies to DICOM3.0 (2000 version).
Revision History Date Version Description 02/08/2004 Ver.1.00 This Conformance Statement applies to DICOM3.0 (2000 version). REGIUS CONSOLE CS-2 DICOM 3.0 Conformance Statement Ver.1.00 02/08/2004 1 Contents
More informationDICOM CONFORMANCE STATEMENT FOR TOSHIBA DIGITAL RADIOGRAPHY SYSTEM MODEL ADR-1000A /R2 (MIIXR0003EAE)
DICOM CONFORMANCE STATEMENT FOR TOSHIBA DIGITAL RADIOGRAPHY SYSTEM MODEL ADR-1000A /R2 (MIIXR0003EAE) 1998-2004 IMPORTANT! (1) No part of this manual may be copied or reprinted, in whole or in part, without
More informationVersion 7 DICOM Conformance Statement. Document Version 3.02, June 2009
Version 7 DICOM Conformance Statement Document Version 3.02, June 2009 1 Conformance Statement Overview The application described in this Conformance Statement VEPRO EMR Manager PACS is a collection of
More informationVersion 9 DICOM Conformance Statement. Version 3.05, September 2015
Version 9 DICOM Conformance Statement Version 3.05, September 2015 1 Conformance Statement Overview The application described in this conformance statement, VEPRO EMR Manager PACS, is a collection of processes
More informationCopyright FUJIFILM Corporation, Japan. August, th Edition 897N100760F
DICOM Conformance Statement ***** FDR-1000AWS CR-IR363AWS for DICOM Storage DICOM Storage Commitment DICOM MWM DICOM MPPS DICOM Print DICOM Query / Retrieve DICOM Media Storage (Standard) August, 2010
More informationPunctual Dicom Workstation
DICOM Conformance Statement Punctual Dicom Workstation Company Name Product Name Product Version 2.0 Document number 2008-1001 Date June 1, 2009 Punctual Software Inc. Punctual Dicom Workstation TABLE
More informationDICOM Conformance Statement
DICOM Conformance Statement SCENARIA Tokyo, Japan E1E-HC0002-01 Hitachi, Ltd. 2016. All rights reserved. History Revision Description Date Rev. 1.0 Initial. 2016/04/01 ii E1E-HC0002 Contents History...
More informationDICOM Conformance Statement
DICOM Conformance Statement DICOM Pro Plus as an SCU Array Corporation Index 0. INTRODUCTION...3 1. IMPLEMENTATION MODEL...4 1.1 APPLICATION DATA FLOW DIAGRAM...4 1.2 FUNCTIONAL DEFINITION OF APPLICATION
More informationWhole Body X-ray CT System Supria. DICOM Conformance Statement
Whole Body X-ray CT System Supria DICOM Conformance Statement Tokyo, Japan (SN-C633E) Copyright Hitachi Medical Corporation. 2013, 2014. All rights reserved. History Revision Description Date Rev. 1.0
More informationTopcon Medical Systems
Topcon Medical Systems EZ Lite 2 Version 1.2 DICOM Conformance Statement November 1, 2013 Rev 1.1 Topcon Medical Systems, Inc. 111 Bauer Drive, Oakland, NJ 07436, USA Phone: (201) 599-5100 Fax: (201) 599-5250
More informationCMT MEDICAL TECHNOLOGIES
CMT MEDICAL TECHNOLOGIES DICOM CONFORMANCE STATEMENT ADR / Product Lines Document Number: 81AR800000 CMT MEDICAL TECHNOLOGIES CMT MEDICAL TECHNOLOGIES, 2007 ALL RIGHTS RESERVED IMPORTANT! 1. The information
More informationSCORE 3D Workstation DICOM CONFORMANCE STATEMENT
Document No.: S517-E105 Revision No.: A DIGITAL ANGIOGRAPHY SYSTEM DAR-9500f SCORE 3D Workstation DICOM CONFORMANCE STATEMENT Revision History Rev. Date Content of Change First 2013.09 Newly issued. A
More informationX-Porte DICOM Conformance Statement
21919 30th Dr. SE, Bothell, WA 98021-3904 USA Telephone 1.425.951.1200 Facsimile 1.425.951.1201 www.sonosite.com Document Number: Revision: Title: D10711 D X-Porte DICOM Conformance Statement CHANGE HISTORY:
More informationAVIA (Dx MM) DICOM 3.0 Conformance Statement
AVIA (Dx MM) DICOM 3.0 Conformance Statement AVIA (Dx MM) is a product of Medasys Digital Systems. Table of Contents 1INTRODUCTION... 4 1.1SCOPE AND AUDIENCE... 4 1.2REFERENCES... 4 1.3ACRONYMS AND ABBREVIATIONS...
More informationDICOM Conformance Statement
DICOM Conformance Statement ECLOS Tokyo, Japan (SN-C357E) Copyright Hitachi Medical Corporation. 2007, 2008. All rights reserved. History Revision Description Date Rev. 1.0 Initial. 2007/02/01 Rev 2.0
More informationDICOM CONFORMANCE STATEMENT
Document No.: S517-1087 Revision: B DAR-7500 DICOM CONFORMANCE STATEMENT MEDICAL SYSTEMS DIVISION Revision History History Date Revision Description 1 st Edition July 2007 - A July.2008 Entirely recreated.
More informationDICOM CONFORMANCE STATEMENT STORAGE SCU FOR TOSHIBA DIGITAL FLUOROGRAPHY SYSTEM MODEL DFP-2000A. with XIDF-053A or XIDF-056A (MIIXR0001EAB)
DICOM CONFORMANCE STATEMENT STORAGE SCU FOR TOSHIBA DIGITAL FLUOROGRAPHY SYSTEM MODEL DFP-2000A with XIDF-053A or XIDF-056A (MIIXR0001EAB) 2000 IMPORTANT! (1) No part of this manual may be copied or reprinted,
More informationDICOM Conformance Statement
For SonixTouch Q+, SonixMDP/SP/OP Q+ and SonixOne Diagnostic Ultrasound Systems (and Systems with Software Version 6.1.0 and Newer) Analogic Corporation 8 Centennial Drive Peabody, MA 01960 USA bkultrasound.com
More informationDAR-9400f DICOM Conformance Statement Revision A
S57-E057A DAR-9400f DICOM Conformance Statement Revision A Revision Date: November 0, 2006 Date Rev. Author Comment 2005.0.4 First Go Takayanagi First Revision 2006..0 A Go Takayanagi Correct the description
More informationVideo Plus Series DICOM Conformance Statement
Video Plus Series DICO Conformance Statement Covering the following products: Video Plus Cardiac Video Plus Cardiac/A Video Plus Angio Video Plus RF Video Plus RF/A Camtronics, Ltd. Version 1.1 Revision
More informationWhole Body X-ray CT System Supria. DICOM Conformance Statement
Whole Body X-ray CT System Supria DICOM Conformance Statement Tokyo, Japan E1E-HC0001-02 Hitachi, Ltd. 2016. All rights reserved. ii E1E-HC0001 History Revision Description Date Rev. 1.0 Initial. 2016/4/1
More informationDICOM Conformance Statement RadWorks 4.0 Product Line
RadWorks 4.0 Product Line Author : Frank Wessels Revision Date : November 1998 Version : 4.0 Document Number : 1996-1998 Applicare Medical Imaging B.V. Name Signature Date Consulting Radiologist Frits
More informationDICOM CONFORMANCE STATEMENT
Ultrasonix Medical Corporation DICOM CONFORMANCE STATEMENT For SonixTablet, SonixTouch, 2010 SonixMDP/SP/OP and Legacy SonixMDP Diagnostic Ultrasound Systems (Software Version 6.0.3 and above) Ultrasonix
More informationPhilips Medical Systems. Intera Document Number April 2003
Philips Medical Systems DICOM CONFORMANCE STATEMENT Intera 10.1 Document Number 4522 131 88821 10 April 2003 Copyright Philips Medical Systems Nederland B.V. 2003 All rights reserved DICOM Conformance
More informationDICOM Conformance Statement. CR-VW 674 for DICOM Storage DICOM Print DICOM MWM DICOM MPPS DICOM Media Storage
DICOM Conformance Statement CR-VW 674 for DICOM Storage DICOM Print DICOM MWM DICOM MPPS DICOM Media Storage December, 2011 7th Edition Copyright FUJIFILM Corporation, Japan 1 CONTENTS 1... CONFORMANCE
More informationRamSoft. PowerServer. DICOM Conformance Statement
RamSoft PowerServer DICOM Conformance Statement PowerServer PACS DICOM Conformance Statement PowerServer PACS DICOM Conformance Statement... 2 1 Introduction... 4 2 Implementation Model... 4 2.1 Application
More informationCONFORMANCE STATEMENT
Philips Medical Systems CONFORMANCE STATEMENT BV Family XA Document Number XPR 080-020061 July 15, 2002 Copyright Philips Medical Systems Nederland B.V. 2002 All rights reserved DICOM Conformance Statement
More informationDICOM Conformance Statement August 23, 2010 Version 1.0 ImageWorks Internal document number:
DICOM Conformance Statement August 23, 2010 Version 1.0 ImageWorks Internal document number: 0000062023 ImageWorks 250 Clearbrook Road, Suite 240 Elmsford, NY 10523 (914) 592-6100 1 Revision History Version
More informationDICOM Conformance Statement for IMAGEnet 5
DICOM Conformance Statement for IMAGEnet 5 Ver.1.0 2013/6/3 TOPCON Corporation ALL RIGHTS RESERVED Conformance Statement for IMAGEnet 5 1 Contents 1. Foreword... 4 1.1. References... 4 1.2. Abbreviations...
More informationKodak Point of Care CR systems. DICOM Conformance Statement
Kodak Point of Care CR systems DICOM Conformance Statement Kodak QC Software Version 2.1.x Aug 21, 2005 Document #AT001008-00 Revision 1.0 Table of Contents REVISION HISTORY 4 ACRONYMS, ABBREVIATIONS AND
More informationSep, th Edition 897N101668H
DICOM Conformance Statement Console Advance DR-ID 300CL/700CL 800CL/900CL for DICOM Storage DICOM Storage Commitment DICOM MWM DICOM MPPS DICOM Print DICOM Query / Retrieve DICOM Media Storage DICOM Dose
More informationAloka ProSound DICOM
11/18/09 Page 1 of 17 Aloka ProSound DICOM Aloka ProSound C3 and C3cv Ultrasound Imaging System ProSound Versions 1.0 and 1.1 DICOM 11/18/09 Page 2 of 17 Table of Contents 1 Introduction...4 1.1 Scope...4
More information1 Introduction Scope and audience References Acronyms and abbreviations 3. 2 Implementation model... 4
NAME FONCTION VISA AUTHOR Alain Battistini Senior Engineer CONFORM TO ORIGINAL REVIEW Jean-François Hoh Senior Engineer CONFORM TO ORIGINAL APPROVAL Pascal Gilbert-Jeantet CONFORM TO ORIGINAL Revision
More informationCarestream DirectView CR System Software Version 5.4. DICOM Conformance Statement
Carestream DirectView CR System Software Version 5.4 DICOM Conformance Statement May 14, 2010 Document # 6K9320 Ver 1.0 Page 1 of 74 Table of Contents 1 INTRODUCTION... 4 1.1 EXECUTIVE OVERVIEW... 4 1.2
More informationFluoroPRO. DICOM conformance Statement
FluoroPRO DICOM conformance Statement Version 1.1 Intended Audience It is assumed that any readers of this document are familiar with the DICOM standard Credits and Trademarks CADRAN TM is a trade mark
More informationFluoroscan InSight V5.0.6 DICOM Conformance Statement
Fluoroscan InSight V5.0.6 DICOM Conformance Statement MAN-02996 Rev 002 Page 1 of 30 1. INTRODUCTION... 4 1.1. Purpose of the Document... 4 1.2. References... 4 1.3. Definitions... 4 2. IMPLEMENTATION
More informationPhilips Medical Systems DICOM Conformance Statement. CT Aura Release 1.3
Philips Medical Systems DICOM Conformance Statement CT Aura Release 1.3 Document Number 4522 220 59761 5 December 2000 Copyright Philips Medical Systems Nederland B.V. 2000 Page ii DICOM Conformance Statement
More informationDICOM Conformance Statement RadWorks Product Line
RadWorks Product Line Version : 5.1 Status : Final Document Number : DCM-1015-050/00-001 1996-2000 Applicare Medical Imaging B.V. Author Position Release Date Signature Jan-Pieter Diender Software Engineer
More informationDAR-9400f / DAR-9500f DICOM Conformance Statement Revision J
S517-E057J Apr. 2016 DAR-9400f / DAR-9500f DICOM Conformance Statement Revision J Revision Date: April, 2016 Revision History Date Rev. Comment 2005.10.4 First First Revision 2006.11.10 A Correct the
More informationDICOM CONFORMANCE STATEMENT FOR ZIOBASE 4.0
DICOM CONFORMANCE STATEMENT FOR ZIOBASE 4.0 DICOM Conformance Statement, Ziobase 4.0 1 Copyright 2006-2012, Ziosoft, Inc. 0 DICOM CONFORMANCE STATEMENT OVERVIEW... 4 1 IMPLEMENTATION MODEL... 5 1.1 APPLICATION
More informationDICOM CONFORMANCE STATEMENT MEDIA STORAGE FOR TOSHIBA DIGITAL FLUOROGRAPHY SYSTEM MODEL DFP-2000A. with XIDF-037A and XIDF-038A or SRS-1000A
DICOM CONFORMANCE STATEMENT MEDIA STORAGE FOR TOSHIBA DIGITAL FLUOROGRAPHY SYSTEM MODEL DFP-2000A with XIDF-037A and XIDF-038A or SRS-1000A (MIIXR0002EAC) 2001 IMPORTANT! (1) No part of this manual may
More informationdicom PACS DX-R Version 3.0
dicompacs DX-R Version 3.0 TABLE OF CONTENTS 1. Introduction... 3 1.1. Revision History... 3 1.2. Abbreviations and Acronyms... 4 2. Implementation Model... 5 2.1. Application Data Flow Diagram... 5 2.2.
More informationXPACS DICOM 3.0 Conformance Statement Document Version October 2004
XPACS DICOM 3.0 Conformance Statement Document Version 1.2.0 28 October 2004 XPACS DICOM 3.0 CONFORMANCE STATEMENT Revision 1.3.0 2 8 October 2004 Page 1 of 25 Table of Contents 0 INTRODUCTION... 4 0.1
More informationDICOM Conformance Statement June 24, 2011 Version 0.4 ImageWorks Internal document number:
DICOM Conformance Statement June 24, 2011 Version 0.4 ImageWorks Internal document number: 0000062015 ImageWorks 250 Clearbrook Road, Suite 240 Elmsford, NY 10523 (914) 592-6100 www.imageworkscorporation.com
More informationTechnical Publications
Technical Publications 1694829 Revision 3 OEC Elite MiniView Software Release Workstation 1.x Copyright 2015 by General Electric Co. g Do not duplicate GE Healthcare REVISION HISTORY REV DATE REASON FOR
More informationDBSWIN DICOM Conformance Statement. DBSWIN DD-DICOM Interface. DICOM Conformance Statement V2.1
DBSWIN DD-DICOM Interface DICOM Conformance Statement V2.1 DÜRR DENTAL Page 1 / 23 Conformance Statement Overview The DBSWIN software controls the digital Dürr Dental imaging products. The DD-DICOM Interface
More informationDICOM CONFORMANCE STATEMENT
Ultrasonix Medical Corporation DICOM CONFORMANCE STATEMENT For Legacy SonixOP, SonixSP, SonixRP and SonixCEP Diagnostic Ultrasound Systems Ultrasonix Medical Corporation 130 4311 Viking Way Richmond, BC
More informationTechnical Publications GE MR DICOM CONFORMANCE STATEMENT. Optima MR430s Software Version DOC Revision 1. GE Healthcare.
GE Healthcare Technical Publications DOC0923546 Revision 1 GE MR DICOM CONFORMANCE STATEMENT Optima MR430s Software Version 3.54 Copyright 2011 by General Electric Co. Do not duplicate CONFORMANCE STATEMENT
More informationDAR-9400f/DAR-9500f with Gateway Option DICOM Conformance Statement. Revision D
S517-E068D Apr. 2014 DAR-9400f/DAR-9500f with Gateway Option DICOM Conformance Statement Revision D Revision Date: April, 2014 Copyright (C) 2005-2014 Shimadzu Corporation. All rights reserved Date Rev.
More informationSonoWin Picture Archiving System
Page 1 of 13 SonoWin Picture Archiving System DICOM SSCU Module Version 4.1 DICOM Conformance Statement Page 2 of 13 1 DOCUMENT HISTORY...4 2 INTRODUCTION...4 2.1 SOURCES OF INFORMATION...4 2.2 ACRONYMS
More informationThis document contains confidential information that is proprietary to SonoSite. Neither the document nor the information contained therein should be
This document contains confidential information that is proprietary to SonoSite. Neither the document nor the information contained therein should be disclosed or reproduced in whole or in part, without
More informationS517-E118 Dec DICOM Conformance Statement
Dec. 2014 DICOM Conformance Statement for NO TEXT 2 Overview: This conformance statement details the compliance to DICOM 3.0 of Side Station RAD for RADspeed Pro system. Table below provides an overview
More informationDICOM Conformance Statement RadWorks 2.1 Product Line
RadWorks 2.1 Product Line Author : Frank Wessels Revision Date : August 1997 Version : 2.1a Document Number : 1996-1997 Applicare Medical Imaging B.V. Name Signature Date Consulting Radiologist Frits Barneveld-
More informationDICOM CONFORMANCE STATEMENT
MultiScan G-Arm System Versions DigiArc 100AU/100AE DICOM CONFORMANCE STATEMENT Whale Imaging 1 / 16 REVISION HISTORY REVISION DATE 1.0 August 5.2013 For information contact Headquarters Whale Imaging
More informationCarestream DRX-Evolution Software Version 5.6b. DICOM Conformance Statement
Carestream DRX-Evolution Software Version 5.6b DICOM Conformance Statement March 6, 2013 Document # 6K9329 Page 1 of 68 Table of Contents INTRODUCTION... 4 1.1 EXECUTIVE OVERVIEW... 4 1.2 SCOPE AND FIELD
More informationg GE Medical Systems Ultrasound
DIRECTION 2361950-100 REV 0 Technical Publications Direction 2361950-100 Revision 0 for DICOM V3.0 Copyright 2002 By General Electric Co. g GE Medical Systems Ultrasound Do not duplicate THIS PAGE LEFT
More informationDAR Revision Date: July,
S517-E053B DAR-9000 Revision Date: July, 25. 2005 DICOM service classes in this manual are provided as an optional item of DAR-9000. For your suitable system configuration, please consult with SHIMADZU
More informationRetinal imaging control software NM. DICOM Conformance Statement
Retinal imaging control software NM DICOM Conformance Statement To Customers 1. Canon reserves the right to change the specifications of the product without prior notice. Microsoft, Windows, Windows XP
More informationUscan. DICOM Conformance Statement
DICOM Conformance Statement - Uscan Uscan DICOM Conformance Statement Software Version: 4.1.1 Date: 3 August 2018 Signostics, Inc., a subsidiary of EchoNous, Inc. 8310 154th Ave NE, Suite 200 Redmond,
More informationDEJARNETTE DICOM/FFP RESEARCH SYSTEMS. DICOM Conformance Statement
DEJARNETTE RESEARCH SYSTEMS DICOM/FFP DICOM Conformance Statement DICOM/FFP Conformance Statement Document Number 090-00-0001 A 7 October 1996 (090-00-0001 A) DICOM_FFP DICOM Conformance Statement.doc
More informationSIEMENS. DICOM Conformance Statement
SIEMENS Siemens Medical Solutions USA, SY CARD, Ann Arbor DICOM Conformance Statement Revision: 9.0 11-12-10 Table of Contents 1. Introduction... 4 1.1 Purpose of this Document... 4 1.2 Sources for this
More informationDigiRoebs 3.1. DICOM Conformance Statement V1.0. medigration GmbH. DICOM Conformace Statement Seite 1 / 38.
DICOM Conformace Statement digiroebs_conformancestatement.doc 17.10.2017 Seite 1 / 38 DigiRoebs 3.1 Last change: Approved by: Am Anger 2 D-91052 Erlangen Tel: +49-(0)7223/9669-0 Fax: +49-(0)7223/6996-610
More informationDICOM Conformance Statement
DICOM Conformance Statement McKesson Cardiology Release 13.2.1 June 2016 Doc ID DCM-10018 Doc Revision 1.0 Produced in Cork, Ireland Revision History Revision Revision Date Summary of Changes Rev. 1.0
More informationDICOM Conformance Statement Centricity RA
Version : 6.0 Status : Final Document Number : DCM-1021-001/00-001 Author Position Release Date Signature Jan-Pieter Diender Program Manager Reviewer Position Review Date Signature Stephan Heerkens Senior
More informationCarestream DRX-Revolution Software Version 5.6. DICOM Conformance Statement
Carestream DRX-Revolution Software Version 5.6 DICOM Conformance Statement June 1, 2012 Document # 6K9336 Page 1 of 68 Table of Contents INTRODUCTION... 4 1.1 EXECUTIVE OVERVIEW... 4 1.2 SCOPE AND FIELD
More informationConformance Statements for MIR CTN Applications
Conformance Statements for MIR CTN Applications Stephen M. Moore Electronic Radiology Laboratory Mallinckrodt Institute of Radiology Version 2.10.0 August 3, 1998 This document contains DICOM conformance
More informationNo. MIIMS0002EAG TOSHIBA MEDICAL SYSTEMS CORPORATION ALL RIGHTS RESERVED
DICOM CONFORMANCE STATEMENT FOR MODEL TWS-2000 SERIES MODEL TWS-3000 SERIES MODEL TWS-5000 SERIES MODEL STWS-005 SERIES MODEL TIS-3000 MODEL TIS-4000 (MIIMS0002EAG) TOSHIBA MEDICAL SYSTEMS CORPORATION
More informationDE32-DCM DentalEye 3.2. DICOM conformance statement
DentalEye 3.2 Table of contents 1. INTRODUCTION... 4 1.1. DentalEye Enterprise Application... 4 1.2. About this Document... 4 1.3. Integration and Validation... 4 1.4. Future Evolution... 5 1.5. Sources
More informationTITAN DICOM Conformance Statement
TITAN DICOM Conformance Statement This document contains confidential information that is proprietary to SonoSite. Neither the document nor the information contained therein should be disclosed or reproduced
More informationTechnical Publications
g GE Medical Systems Technical Publications Direction 2206867 Revision 1.0 DICOM Software V2.0 for DICOM V3.0 Copyright ª 1997 By General Electric Co. Do not duplicate 1 g GE Medical Systems THIS PAGE
More informationWINRAD-32 Teleradiology System Conformance Claim
WINRAD-32 Teleradiology System Conformance Claim Revision: 2.1 Date: February 13, 2001 Copyright 1998-2001 by LINE Imaging Systems, L.L.C. Revision History Revision Date Author Reason for Change 2.0 Feb
More informationPhilips Medical Systems DICOM Conformance Statement. Inturis Suite R2.2
Philips Medical Systems DICOM Conformance Statement Inturis Suite R2.2 Document Number XZR 080-010044 8 February 2002 Copyright Philips Medical Systems Nederland B.V. 2002 Page ii DICOM Conformance Statement
More informationDICOM Conformance Statement * /02* /02 MADE IN GERMANY
EN DICOM 9000-608-109/02 *9000-608-109/02* MADE IN GERMANY Overview Vet-Exam Intra controls the digital DÜRR MEDICAL imaging products. The Vet-Exam Intra DICOM Interface translates between DICOM applications
More informationCarestream OnSight 3D Extremity System ImageView Software Version 1.0. DICOM Conformance Statement
Carestream OnSight 3D Extremity System ImageView Software Version 1.0 DICOM Conformance Statement November 15, 2016 Document # 9K1877 PAGE 1 of 92 Table of Contents INTRODUCTION... 4 1.1 EXECUTIVE OVERVIEW...
More informationDICOM Conformance Statement Merge RadSuite v
DICOM Conformance Statement Merge RadSuite v. 8.30.1 Merge Healthcare 900 Walnut Ridge Drive Hartland, WI 53029 877.44.MERGE Copyright 2011 Merge Healthcare. All rights reserved. This document, the information
More informationNo. : S Rev. : A. DICOM Conformance Statement For Side Station Rev02.00
No. : S517-1076 Rev. : A DICOM Conformance Statement For Side Station Rev02.00 Overview: Side Station DICOM3.0 Conformance Statement This conformance statement details the Side Station s compliance to
More informationCarestream DRX-1 System Carestream DRX-Mobile Retrofit Kit Software Version 5.3. DICOM Conformance Statement
Carestream DRX-1 System Carestream DRX-Mobile Retrofit Kit Software Version 5.3 DICOM Conformance Statement July 9, 2010 Document # 8J4601 PAGE 1 of 60 Table of Contents INTRODUCTION...4 1.1 EXECUTIVE
More informationOASIS V4.0 DICOM Conformance Statement Rev. 3
0BMR Imaging System OASIS V4.0 DICOM Conformance Statement Rev. 3 Tokyo, Japan E1E-BM7403-3 Copyright Hitachi Medical Corporation. 2011. All rights reserved. Revision History Revision Date Change Description
More informationDICOM Conformance Statement Product Name HCP DICOM Net Version
Title DICOM Conformance Statement Product Name HCP DICOM Net Version 5.00.00 Copyright - 2000-2013 SoftLink International Pvt. Ltd. SoftLink International Pvt. Ltd. Page 1 of 37 2, Anand Park, Aundh, Pune
More informationTechnical Publications
Technical Publications LOGIQ E9 CONFORMANCE STATEMENT for DICOM Do not duplicate Copyright 2011 By GE Healthcare REVISION HISTORY Revision Date Description Author 1 Draft May 27 th, 2008 Dominick Anggara
More informationDICOM Conformance Statement
DICOM Conformance Statement Application Annex: AneurysmFlow R1.1 On Interventional Workspot R1.5 Koninklijke Philips N.V. 2018 All rights are reserved. Issued by: Philips Medical Systems Nederland BV,
More informationTechnical Publications
DOC0445444 REV 2 Technical Publications DOC0445444 Revision 2 CONFORMANCE STATEMENT for DICOM Do not duplicate Copyright 2008 By GE Healthcare DOC0445444 REV 2 THIS PAGE LEFT INTENTIONALLY BLANK DOC0445444
More informationQPC XSCAN32 DICOM 3.0 Conformance Statement Document Version October 2004
QPC XSCAN32 DICOM 3.0 Conformance Statement Document Version 1.3.0 28 October 2004 QPC XSCAN32 DICOM 3.0 CONFORMANCE STATEMENT Revision 1.3.0 2 8 October 2004 Page 1 of 22 Table of Contents 0 INTRODUCTION...
More informationPhilips Medical Systems. Xcelera R1.1L1. Document Number XPR July 2003
Philips Medical Systems DICOM CONFORMANCE STATEMENT Xcelera R1.1L1 Document Number XPR 080-030073 11 July 2003 Copyright Philips Medical Systems Nederland B.V. 2003 All rights reserved 3 DICOM Conformance
More informationPhilips Medical Systems DICOM Conformance Statement
Philips Medical Systems DICOM Conformance Statement DSI Pro 2.0 Document Number 4522 164 09301 4 February 2002 Copyright Philips Medical Systems Nederland B.V. 2002 Page ii DICOM Conformance Statement
More informationDxMM/DxWin DICOM 3.0 Conformance Statement. Document Reference (Référence du document) : 99/ Oct30/ABA/MM103/398B
DxMM/DxWin DICOM 3.0 Conformance Statement Document Reference (Référence du document) : 99/ Oct30/ABA/MM103/398B Table of Contents (Table des Matières) 1 Introduction 6 1.1 Scope and Audience 6 1.2 References
More informationDICOM Conformance Statement
1 of 6 DICOM Conformance Statement DICOM Conformance Statement Review Station software Review Station (ERS) software is an image reviewing software application that reads and displays DICOM- compliant
More informationDICOM. Conformance Statement For VINNO Medical Ultrasound System Revision 2.0. Copyright 2012 by VINNO Technology (Suzhou) Co., Ltd.
DICOM Conformance Statement For VINNO Medical Ultrasound System Revision 2.0 Copyright 2012 by VINNO Technology (Suzhou) Co., Ltd. 1 / 37 Revision History Document version Date Author Description 1.0 2014-07-10
More informationTechnical Publications
Technical Publications Direction 2193691DNT Revision 4 STENOSCOP 6000/9000 MDA and MDA Plus for DICOM V3.0 Copyright 1997 By General Electric Co. Do not duplicate GE Medical Systems 1/42 REVISION HISTORY
More informationTechnical Publication. DICOM Conformance Statement. BrainSUITE NET 1.5. Document Revision 1. March 5, Copyright BrainLAB AG
Technical Publication DICOM Conformance Statement Document Revision 1 March 5, 2009 2009 Copyright BrainLAB AG 1 Conformance Statement Overview This is a conformance statement for the BrainLAB software
More informationTechnical Publications
DIRECTION 2325843-100 REV 9.02 LOGIQ 9 Technical Publications Direction 2325843-100 Revision 9.02 LOGIQ 9 CONFORMANCE STATEMENT for DICOM Do not duplicate Copyright ª 2009 By GE Healthcare DIRECTION 2325843-100
More informationDICOM Conformance Statement. CT AV Series Product Line. Document Number February 1997
Philips Medical Systems DICOM Conformance Statement CT AV Series Product Line Document Number 4522 983 65911 28 February 1997 Copyright Philips Medical Systems Nederland B.V. 1997 Philips Medical Systems
More informationPrintlink III-ID/IV. Revision History. Date Version Description 20/08/2004 Ver First edition
Revision History Date Version Description 20/08/2004 Ver. 1.00 First edition NOTE: Descriptions in this document are subject to change without prior notice. Printlink III-ID/IV DICOM 3.0 Conformance Statement
More informationTechnical Publications
Technical Publications Direction DOC0913087 Revision 1.0 VOLUSON Voluson S6/S8 11.x.x Copyright 2011 by General Electric Co. Do not duplicate GE Medical Systems THIS PAGE LEFT INTENTIONALLY BLANK REVISION
More informationDICOM Conformance Statement for Selenia Dimensions Acquisition Workstation Software Version 1.8 Part Number MAN Revision 002
DICOM Conformance Statement for Selenia Dimensions Acquisition Workstation Software Version 1.8 Part Number MAN-04089 Revision 002 April 2015 Table of Contents Selenia Dimensions 1.8 DICOM Conformance
More informationDICOM Conformance Statement. CharruaPACS
CharruaPACS _en Version: 2.0 Reviewed by: Rafael Sanguinetti Approved by: Rafael Sanguinetti Date: 06/25/2014 Date: 06/25/2014 Page 1 of 14 CharruaPACS CharruaPACS _en Version 2.0 Page 2 of 14 Table of
More informationTechnical Publications
Technical Publications Direction 2316173-100 Revision 8.00 LOGIQ 7 CONFORMANCE STATEMENT for DICOM Do not duplicate Copyright ª 2008 By GE Healthcare THIS PAGE LEFT INTENTIONALLY BLANK REVISION HISTORY
More information